Karnataka State Small Industries Development Corporation Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka State Small Industries Development Corporation - KSSIDC Tender

Works
Bridge Construction
Civil And Construction
Electronics Equipment
Road Construction
Civil Works Others
Drainage Work
Electrical and Electronics
Electrical Works
Opening Date20 Jul 2024
Closing Date20 Aug 2024
Tender Amount₹ 13,77,88,905.51 
Notes
Download

Costs

Summary

Establishment Of New Industrial Estate At Budihal Grama-ballolli Hobli,indi Tq,vijayapura Dist

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Removal of stumps and roots including backfilling with suitable material to required compaction. Girth from 300 mm to 600 mm PWD SOR for Roads and Bridges - 2023-24 Item No. VOL-III-2.1-b-i Page No.9

250

366

91670

... More
code05 - Removal of stumps and roots including backfilling with suitable material to required compaction. Girth from 600 mm to 900 mm PWD SOR for Roads and Bridges - 2023-24 Item No. VOL-III-2.1-b-ii Page No.9

350

501

175563.5

... More
code06 - Earth work in surface excavation by mechanical means for lowering and leveling the ground for all works other than foundation in all kinds of soils and upto depth not exceeding 300mm as per drawing and technical specifications including setting out shoring strutting barricading caution lights removal of stumps and other deleterious matter including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.12 Page No.8

4602.5

97

450354.625

... More
code07 - Earth work in surface excavation by mechanical means for lowering and leveling the ground without blasting for all works other than foundation in OrdinaryperSoft rock and depth not exceeding 300mm as per drawing and technical specifications including setting out shoring strutting barricading caution lights removal of stumps and other deleterious matter including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenances required to complete the work In OrdinaryperSoft rock upto 300 mm depth Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.13 Page No.8

1972.5

372

735466.35

... More
code08 - Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded with desired compaction. Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.7 Page No.7

2301.25

122

282064.2125

... More
code09 - Construction of Embankment by excavating the available approved GravelperMurrum deposited at a place or borrow pits during or prior excavation with all lifts and lead transportation to site spreading grading to required slope and compacting to meet the requirement complete as per specifications including cost of labour rolling water all materials usageand all other appurtenaces required to complete the work. Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.8 Page No.7

10017.75

488

4890865.905

... More
code10 - Road Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.14.1 Page No.8

1345.959

105

141406.45254

... More
code11 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work. In ordinarypersoft rock without blasting upto 1.5 m depth Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.15.1 Page No.8

384.56

373

143783.1384

... More
code12 - Earth work excavation for Foundation by mechanical means for all works and depth upto 1.5 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In Hard Rock requiring blasting Depth upto 1.50m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.16.1 Page No.9

192.28

570

109718.8136

... More
code13 - Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded with desired compaction. Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.7 Page No.7

672.979

122

82487.03603

... More
code14 - Construction of Embankment by excavating the available approved GravelperMurrum deposited at a place or borrow pits during or prior excavation with all lifts and lead transportation to site spreading grading to required slope and compacting to meet the requirement complete as per specifications including cost of labour rolling water all materials usageand all other appurtenaces required to complete the work. Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.8 Page No.7

1110.05

488

541948.611

... More
code15 - Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads transporting to site spreading grading to required slope and compacted to meet requirement of table No. 300-2 PWD SOR for Roads and Bridges - 2023-24 Item No. VOL-III-3.6 Page No.17

8640.51

507

4387564.5729

... More
code16 - Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC carriage of mixed Material to work site spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density complete as per clause 401. For Grading -V Material PWD SOR for Roads and Bridges - 2023-24 Item No. VOL-III-4.1-v Page No.23

3002.49

2561

7691208.4089

... More
code17 - Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS 383 the size of coarse aggregate not exceeding 25 mm aggregate cement ratio not to exceed 14 1 aggregate gradation after blending to be as per table 600-1 cement content not to be less than 140 kgper m3 optimum moisture content to be determined during trial length construction concrete strength not to be less than 7 Mpa at 7 days mixed in a batching plant transported to site laid with a paver with electronic sensor compacting with 8-10 t vibratory roller finishing and curing. PWD SOR for Roads and Bridges - 2023-24 Item No. VOL-III-6.1 Page No.49

1131.81

5067

5735560.356

... More
code18 - Construction of M30 Grade un-reinforced dowel jointed plain cement concrete pavement over a prepared sub base with OPC at 270 kgperm3 and GGBSat 90 kgperm3 coarse and fine aggregate conforming to IS 383 2016 maximum size of coarse aggregate not exceeding 25 mm mixed in a batching and mixing plant as per approved mix design transported to site laid with a paver finisher spread compacted and finished in a continuous operation including provision of contraction expansion construction and longitudinal joints joint filler separation membrane sealant primer joint sealant debonding strip dowel bar tie rod admixtures curing compound steel channels finishing to lines and grades as per drawing. PWD SOR for Roads and Bridges - 2023-24 Item No. VOL-III-6.5 Page No.50

2186.3

8074

17652557.871

... More
code19 - Providing and laying of Road marking with hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads at 250 gperm2 area thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35 2015.The finished surface to be level uniform and free from streaks and holes PWD SOR for Roads and Bridges - 2023-24 Item No. VOL-III-8.15 Page No.67

692.55

545

378063.045

... More
code20 - Supplying and fixing of Solar Raised Pavement Markers made of polycarbonate molded body with circular shape solar powered LED self illumination in active mode 360 degree illumination and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face in passive mode. The marker shall support a load of 20000 kg tested in accordance to ASTMD 4280. The marker should be resistant to dust and water ingress according to IP 65 standards and should withstand tempertures in the range of 0 C to 70 C. Color of lighting could be provided in red or yellow amber as per requirement and typicl frequency of blinking is 1 Hz. There should be current losses of less than 20 microamperes at 2.4 V in sleepcharging mode to enhance the life of the marker and a full charge should provide for a minimum autonomy of 50 hours. The height width and length of the marker shall not PWD SOR for Roads and Bridges - 2023-24 Item No. VOL-III-8.32 Page No.71

1221

2163

2641023

... More
code21 - Drain Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.14.1 Page No.8

3409.559

105

358208.26854

... More
code22 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work. In ordinarypersoft rock without blasting upto 1.5 m depth Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.15.1 Page No.8

974.159

373

364228.30851

... More
code23 - Earth work excavation for Foundation by mechanical means for all works and depth upto 1.5 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In Hard Rock requiring blasting Depth upto 1.50m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.16.1 Page No.9

487.08

570

277937.5896

... More
code24 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. Mix 1 3 6 Using 40 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.1.3 Page No.15

579.9

6168

3577211.733

... More
code25 - Providing and laying in Cement Concrete for all Basement and surface level works return walls retaining walls sunken floors etc. The granitepertrapper basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators providing weep holes wherever necessary including all lead and lifts cost of all materials of quality labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.3.1 Page No.16

1391.67

8792

12235743.5571

... More
code26 - Supplying fitting and placing TMT FE 550 per 550D Steel Reinforcement including cost of all materials machinery labour cleaning straightening cutting bending hooking lapingperwelding joints tying with binding wire per soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.11.h Page No.18

90.459

81381

7361673.73047

... More
code27 - Filling available excavated earth excluding rock in trenches plinth sides of foundations and other similar works etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.9 Page No.7

521.87

273

142981.9426

... More
code28 - Culvert Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.14.1 Page No.8

376.277

105

39531.66162

... More
code29 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work. In ordinarypersoft rock without blasting upto 1.5 m depth Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.15.1 Page No.8

107.508

373

40196.16612

... More
code30 - Earth work excavation for Foundation by mechanical means for all works and depth upto 1.5 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In Hard Rock requiring blasting Depth upto 1.50m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.16.1 Page No.9

53.754

570

30673.10748

... More
code31 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. Mix 1 3 6 Using 40 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.1.3 Page No.15

172.44

6168

1063725.4548

... More
code32 - Providing and laying in Cement Concrete for all Basement and surface level works return walls retaining walls sunken floors etc. The granitepertrapper basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators providing weep holes wherever necessary including all lead and lifts cost of all materials of quality labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.3.2 Page No.16

252.18

8009

2019780.2304

... More
code33 - Supplying fitting and placing TMT FE 550 per 550D Steel Reinforcement including cost of all materials machinery labour cleaning straightening cutting bending hooking lapingperwelding joints tying with binding wire per soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.11.h Page No.18

30.262

81381

2462761.80846

... More
code34 - Filling available excavated earth excluding rock in trenches plinth sides of foundations and other similar works etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.9 Page No.7

85.68

273

23474.6064

... More
code35 - Reinforced cement concrete M30 grade for approach slab including reinforcement and formwork complete as per drawing and Technical specification Batching Plant PWD SOR for Roads and Bridges - 2023-24 Item No. VOL-III-13.9 Page No.122

231

12190

2815901.55

... More
code36 - Duct chamber Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work. In ordinarypersoft rock without blasting upto 1.5 m depth Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.15.1 Page No.8

33.902

373

12675.61878

... More
code37 - Earth work excavation for Foundation by mechanical means for all works and depth upto 1.5 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In Hard Rock requiring blasting Depth upto 1.50m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.16.1 Page No.9

16.951

570

9672.57962

... More
code38 - Earth work excavation by manual means for drains canals waste weir draft approach channels key trenches foundation of Buildings and bridges and such simillar works in all kinds of soils as per drawing and technical specifications including setting out shoring strutting barricading caution lights removal of stumps and other deleterious matter excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools and other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.4.1 Page No.5

118.656

249

29576.19456

... More
code39 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. Mix 1 3 6 Using 40 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.1.3 Page No.15

18.82

6168

116094.3694

... More
code40 - Providing and laying in position Cement Concrete for all Sub structures of building Irrigation works Sub structure works of bridges Drain works and other parallel works from 0.50m to 3.50 m height. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators providing weep holes erevernecessary including all lead and lifts cost of all materials of uality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M 25 Using 20 mm nominal size graded crushed coarse aggregate Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.4.3 Page No.16

37.46

6852

256690.1548

... More
code41 - Supplying fitting and placing TMT FE 550 per 550D Steel Reinforcement including cost of all materials machinery labour cleaning straightening cutting bending hooking lapingperwelding joints tying with binding wire per soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.11.h Page No.18

1.873

81381

152427.23109

... More
code42 - Filling available excavated earth excluding rock in trenches plinth sides of foundations and other similar works etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.9 Page No.7

20.06

273

5496.0388

... More
code43 - Refilling available earth around trenchesperpipelines cables in layers not exceeding 20 cms in depth compacting each deposited layer by ramming after watering with a lead upto 50 m and lift upto 1.5 m. Including cost of all labour complete as per specifications Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.10 Page No.7

27.36

164

4508.928

... More
code44 - Providing SandS RCC SPUN per VIBRATED CAST PIPES REINFORCED pipes NP-3 Class 300 mm dia conforming to IS 458-1988 with latest amentments using ordinary portland cement for sanitary works and conveying to work site rolling and lowering into trenches laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials perfect linking of joints with jack to correct position including cost of jointing materials i.e rubber rings conforming to IS 5382 for SandS RCC pipes with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. Contractor will make his own arrangements for procuring water for testing . Before the execution of the work the contractor shall carry out the survey PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 16.3.2 Page No.188

228

1371

312806.88

... More
code45 - Singane and boards Boundary stones and Tree plantation Earth work excavation by manual means for drains canals waste weir draft approach channels key trenches foundation of Buildings and bridges and such simillar works in all kinds of soils as per drawing and technical specifications including setting out shoring strutting barricading caution lights removal of stumps and other deleterious matter excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools and other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.4.1 Page No.5

76.32

249

19023.5232

... More
code46 - Direction and Place Identification Signs upto 0.9 m2 Size Board. Providing and erecting direction and place identification retro reflectorised sign as per IRC 67 2022 made of high intensity grade sheeting vide clause 801.3 fixed over aluminium sheeting 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area not exceeding 0.9 m2 fixed over back support frame of min 35 x 35 x 3mm angle mounted on a mild steel circular pipe 65 NB firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm 60 cm below ground level as per approved drawing PWD SOR for Roads and Bridges - 2023-24 Item No. VOL-III-8.7 Page No.65

2.7

9280

25056.81

... More
code47 - Providing and fixing of retro- reflectorised cautionary mandatory and informatory sign as per IRC 67 2022 made of Class C Type XI retro reflective sheeting fixed over 2 mm thick aluminium sheeting vide clause 801.3 3mmper4mm thick Aluminium composite material sheet depending on the size of the sign fixed over the back support frame of min 25 x 25 x 3mm angle mounted on a mild steel circular pipe 65 NB 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm 60 cm below ground level as per approved drawing.The sign shall be maintained as per section 12 of IRC 67 2022. 80 mm x 60 mm rectangular PWD SOR for Roads and Bridges - 2023-24 Item No. VOL-III-8.6- x Page No.65

19

5670

107732.85

... More
code48 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. Mix 1 3 6 Using 40 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.1.3 Page No.15

69

6168

425638.23

... More
code49 - Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC 25 fixed in position including finishing and lettering but excluding painting Boundary pillar per Guard Stone PWD SOR for Roads and Bridges - 2023-24 Item No. VOL-III-8.18 Page No.67

407

770

313569.08

... More
code50 - Digging pits of size 0.75 x 0.75x 0.75m filling 50percentage of the pit with top soil and remaining 50percentage of pit with 1 2 3 proportion of sand 0.035cum FYM 0.070cum Red earth 0.105 cum and planting of well grown tree saplings excluding cost of plants PWD SOR for Roads and Bridges - 2021-22 Item No. VOL-XIII-12.2 Page No.48

316.21

1116

352890.36

... More
code51 - Chain link fencing Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.14.1 Page No.8

460.277

105

48356.70162

... More
code52 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work. In ordinarypersoft rock without blasting upto 1.5 m depth Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.15.1 Page No.8

131.508

373

49169.52612

... More
code53 - Earth work excavation for Foundation by mechanical means for all works and depth upto 1.5 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In Hard Rock requiring blasting Depth upto 1.50m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.16.1 Page No.9

65.754

570

37520.54748

... More
code54 - Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1 6 1 cement 6 coarse sand PWD SOR for Buildings - 2023-24 Item No. VOL-II-5.4 Page No.9

249.84

6580

1644114.5928

... More
code55 - Providing and fixing Structural Steel work riveted bolted or welded in built up sections trusses and framed work including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge PWD SOR - 2023-24 Item No. VOL-II-11.2 Page No.77

17486.64

116

2035270.0296

... More
code56 - Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts bolts and washers as required complete as per the direction of Engineer-in-charge PWD SOR - 2023-24 Item No. VOL-II-11.60 Page No.96

2414

919

2220373.06

... More
code57 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. Mix 1 3 6 Using 40 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.1.3 Page No.15

109.49

6168

675407.6783

... More
code58 - Providing and laying in position Cement Concrete for all Foundation works. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers well compacted using needle vibrators including all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.2.1 Page No.15

3.659

6993

25589.76535

... More
code59 - Providing and laying in position Cement Concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators. The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.5.1 Page No.16

1.69

11609

19619.4297

... More
code60 - Supplying fitting and placing TMT FE 550 per 550D Steel Reinforcement including cost of all materials machinery labour cleaning straightening cutting bending hooking lapingperwelding joints tying with binding wire per soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.11.h Page No.18

0.535

81381

43539.01155

... More
code61 - Filling available excavated earth excluding rock in trenches plinth sides of foundations and other similar works etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.9 Page No.7

294.549

273

80700.53502

... More
code62 - Water Supply Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications including setting out construction of shoring strutting barricading caution lights bracing using sight rails and boning rods at every 100 mm whevere necessary as directed removal of stumps and other deleterious matter dressing of sides and levelling the bottom of trench to the extent required utilising the available excavated earth locally for the work etc. and all other appurtenances complete in the following strata. In all kinds of soil. Depth upto 1.50m PWD SR 2023-24 Vol-I P-10 Sl-1.17.1

686.699

269

185312.59214

... More
code63 - Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifications including setting out construction of shoring strutting barricading caution lights bracing using sight rails and bonding rods at every 100 mm whevere necessary as directed removal of slumps and other deleterious matter dressing of sides and levelling the bottom of trench to the extent required utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Ordinaryorsoft rock without requiring blasting Depth upto 1.50 m PWD SR 2023-24 Vol-I P-10 Sl-1.19.1

196.2

467

91747.044

... More
code64 - Earth work excavation for pipeline trenchesby mechanical means above 600 mm trench width as per drawing and technical specification including setting out construction of shoring strutting cost of blasting materialsbarricading caution lights bracing using sight rails and boning rods at every 100 mm whevere necessary as directed removal of slumps and other deleterious matter dressing of sides and levelling the bottom of trench to the extent required utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Hard rock blasting prohibited Depth upto 1.50 m PWD SR 2023-24 Vol-I P-11 Sl-1.21.5

98.1

1044

102457.602

... More
code65 - Providing and Filling in foundation with granite or trap broken metal 100mm. and down size and with approved sand ncluding hand packing ramming watering including cost of all materials and labour with all lead and lift complete as per specifications PWD SR 2023-24 Vol-I P-11 Sl-1.23

277.52

2762

766637.8992

... More
code66 - Providing laying and jointing HDPE pipes 63mm dia pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches laying true to line and jointing of pipes and specials with electrofusion welding giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee stub ends flanged sets bedns reducers etc. complete Contractor will make his own arrangements for procuring water for testing etc. complete. NOTE Upto 110mm dia Coil shall be used. PWD SR 2023-24 Vol-V P-102 Item no. 9.11.1

2011

192

387338.71

... More
code67 - Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour all lead and lift including encasing the Specials around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. 63 mm Electro Fusion Coupler PWD SR 2023-24 Vol-V P-102 Item no. 9.17.27

5

145

726.15

... More
code68 - Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour all lead and lift including encasing the Specials around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. 63 mm Electro Fusion Tee PWD SR 2023-24 Vol-V P-102 Item no. 9.17.30

50

253

12669

... More
code69 - Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour all lead and lift including encasing the Specials around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. 63 mm Electro Fusion Elbow PWD SR 2023-24 Vol-V P-102 Item no. 9.17.33

40

254

10176.4

... More
code70 - Supply and fixing of Single or Double chamber triple function tamper proof Both the orifces to be housed in the single chamber Air valves with Body and cover in Ductile cast iron of grade GGG 40or50. All internal parts such as float shell with appurtenances. all cover bolts of austenitic alloy or SS 304 steel DN 50 float of HOSTAFLON or SS 304 and gaskers and seals of EPDM. Epoxy powder coating EP-P inside and outside colour blue RAL5005. The valves should be designed for all the three functions i.e. 1. Large orifice for venting of large air volumes on start up. 2. Large orifice for intake of large air volumes. 3. Small orifice for discharge of pressurized air during operation. For PN 10.0 For TP Air Valves of 50mm dia. PWD SR 2023-24 Vol-5 P-28 Item no.-2.35.1

4

29036

116146.92

... More
code71 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron DI conforming to IS-1865 and of grade GGG 40or50 shaft of stainless steel wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings minimum 2 “ O “ rings. Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves T.P set galvanized bolts and nuts and rubber insertions etc. but excluding earth work. Note TP set should be considered only for DI pipes estimate. For MS pipes estimates TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate. For PN-10. Sluice valve-50 mm dia PWD SR 2023-24 Vol-5 P-28 Item no.-2.23.1

10

5701

57010.5

... More
code72 - Refilling available earth around trenchesorpipelines cables in layers not exceeding 20 cms in depth compacting each deposited layer by ramming after watering with a lead upto 50 m and lift upto 1.5 m. Including cost of all labour complete as per specifications PWD SR 2023-24 Vol-I P-7 Sl-1.10

506.01

164

83390.448

... More
code73 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In ordinaryorsoft rock without blasting up to 1.5 m depth PWD SR 2023-24 Vol-I P-8 Sl-1.14.1

45.08

105

4736.1048

... More
code74 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In ordinaryorsoft rock without blasting up to 1.5 m depth PWD SR 2023-24 Vol-I P-8 Sl-1.15.1

12.88

373

4815.7032

... More
code75 - Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including cost of explosives dressing of excavated surfaces disposing off or levelling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour blasting materials tools usage of Machinery and all other appurtenaces required to complete the work In Hard Rock requiring blasting Depth upto 1.5 m PWD SR 2023-24 Vol-I-P-9 Sl-1.16.1

6.44

570

3674.7928

... More
code76 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machineries curing and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement and formwork shall be paid separately Mix 136 M10 Using 40 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 VOL-I Sl. 2.1.3 or Page No. 15

8.4

6168

51816.828

... More
code77 - Providing and laying in position Reinforced cement concrete for all Foundation works. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers well compacted using needle vibrators including all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement and formwork to be paid separately M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 Vol-I P-15 Sl-2.2.1

25.339

6799

172289.74321

... More
code78 - Supplying fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials machinery labour cleaning straightening cutting bending hooking lapingorwelding joints tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures PWD SR 2023-2024 Item No. VOL-I-2.11-h Page No.18

1.266

81381

103028.76378

... More
code79 - Filling available excavated earth excluding rock in trenches plinth sides of foundations and other similar works etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m. PWD SR 2023-24 Vol-I P-7 Sl-1.9

10.64

273

2915.1472

... More
code80 - Providing and fixing 3 layer PP-R Poly Propylene Random Copolymer pipes confirming to IS.15801 2008 OR WRAS NSF certificates which is UV stabilized and anti-microbial fusion welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings including fixing the pipe with clamps at 1.00 m spacing. This includes Lot wise test report as per the relevant ISor ISOorDINorBIS codes and also testing of joints complete as per direction of Engineer-In-Charge.etc. PN-16 PipeSDR 7.4-20 mm OD PWD SOR for Water Supply and Sewerage Works-2023-24 Item No. VOL-5-2.62.2 Page No.35

124.5

211

26288.175

... More
code81 - Providing and fixing 3 layer PP-R Poly Propylene Random Copolymer pipes confirming to IS.15801 2008 OR WRAS NSF certificates which is UV stabilized and anti-microbial fusion welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings including fixing the pipe with clamps at 1.00 m spacing. This includes Lot wise test report as per the relevant ISor ISOorDINorBIS codes and also testing of joints complete as per direction of Engineer-In-Charge.etc. PN-16 PipeSDR 7.4-50 mm OD PWD SOR for Water Supply and Sewerage Works-2023-24 Item No. VOL-5-2.62.6 Page No.35

373.5

685

256213.53

... More
code82 - OHT Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.14.1 Page No.8

29.98

105

3149.6988

... More
code83 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work. In ordinarypersoft rock without blasting upto 1.5 m depth Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.15.1 Page No.8

8.57

373

3204.2373

... More
code84 - Earth work excavation for Foundation by mechanical means for all works and depth upto 1.5 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In Hard Rock requiring blasting Depth upto 1.50m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.16.1 Page No.9

4.28

570

2442.2536

... More
code85 - Earth work excavation for Foundation by mechanical means for all works and depth upto 1.5 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In Hard Rock requiring blasting Depth exceeding 1.50m but not exceeding 3 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.16.2 Page No.9

10.71

673

7216.0767

... More
code86 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1 4 1 cement 4 fine sand including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineer-in-charge. PWD SOR for Buildings - 2023-24 Item No. VOL-II-8.2.1 Page No.41

249.91

303

75935.1535

... More
code87 - Finishing walls with water proofing cement paint of required shade New work Two coats applied at 4.84 kgper10 m² to give an even shade after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer-in-charge. PWD SOR for Buildings - 2023-24 Item No. VOL-II-8.28 Page No.45

249.91

91

22909.2497

... More
code88 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer-in-charge. PWD SOR for Buildings - 2023-24 Item No. VOL-II-8.41 Page No.48

6.3

172

1083.663

... More
code89 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners all necessary fittings complete including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. PWD SOR - 2023-24 Item No. VOL-II-11.5.1 Page No.77

6.3

4612

29057.742

... More
code90 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. Mix 1 3 6 Using 40 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.1.3 Page No.15

2.736

6168

16877.48112

... More
code91 - Providing and laying in position Cement Concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators. The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.5.3 Page No.16

5.568

7048

39244.15488

... More
code92 - Providing and laying in position Cement Concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators. The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.5.3 Page No.16

8.5725

13279

113839.88535

... More
code93 - Providing and laying in position Cement Concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators. The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.5.3 Page No.16

9.5134

12557

119468.706396

... More
code94 - Providing and laying in position Cement Concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators. The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.5.3 Page No.16

1.853

11836

21932.51566

... More
code95 - Providing and laying in position Cement Concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators. The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.5.3 Page No.16

8.373

8949

74932.82382

... More
code96 - Providing and laying in position Cement Concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators. The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.5.3 Page No.16

34.994

11836

414196.68268

... More
code97 - Supplying fitting and placing TMT FE 550 per 550D Steel Reinforcement including cost of all materials machinery labour cleaning straightening cutting bending hooking lapingperwelding joints tying with binding wire per soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.11.h Page No.18

10.33

81381

840669.1389

... More
code98 - Filling available excavated earth excluding rock in trenches plinth sides of foundations and other similar works etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.9 Page No.7

42.835

273

11735.9333

... More
code99 - Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron DI conforming ti IS-1865 with the latest amendments and of grade GGG 40per50 shaft of stainless steel wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings minimum 2 O rings . Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves T.P set galvanized bolts and nuts and rubber insertions etc. but excluding earth work. For PN-10 Note TP set should be considered only for DI pipes estimate. For MS pipes estimates TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate. etc. complete. For sluice Valve of PN - 10.0 and 80mm PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 2.23.2 Page No.22

2

10704

21409.58

... More
code100 - Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron DI conforming ti IS-1865 with the latest amendments and of grade GGG 40per50 shaft of stainless steel wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings minimum 2 O rings . Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves T.P set galvanized bolts and nuts and rubber insertions etc. but excluding earth work. For PN-10 Note TP set should be considered only for DI pipes estimate. For MS pipes estimates TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate. etc. complete. For sluice Valve of PN - 10.0 and 100mm PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 2.23.3 Page No.22

1

11210

11210.52

... More
code101 - Providing and fixing MS ladder between landings 45 cms wide using angle iron of specified sizes 20mm MS bars at 25 cms. centre to centre with necessary supports of same angle iron etc. as directed including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh including fixing in ground with CC 1 2 4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with MS angle of 65 x 65 x 8mm PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 7.1 Page No.85

13.5

4508

60862.185

... More
code102 - Providing and fixing MS inspection door of size 60 cms x 60 cms including MS frame made of 50x50x6mm angle shutters made of 3mm thick MS sheets with hinges locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 7.3 Page No.85

1

2204

2204.2

... More
code103 - Providing and fixing RCC final and ventilators as per approved design and specifications with form works and protected with wire mesh. The plinth to be of RCC circular pillars and canopy with an ornamental finish at top. The first 22.5 cms height to be covered with RCC panelling as per detailed drawings etc. with all lead and lifts and excluding reinforcement steel PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 7.2.3 Page No.85

1

11122

11122.97

... More
code104 - Providing and fixing gauge with iron sheet or enamelled guage plate of 3mm to 4mm thick 0.23 M width with copper floats indicators and flexible nylone wires painting figures with approved enamel paint etc. PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 7.4.3 Page No.85

1

7255

7255.32

... More
code105 - Providing and fixing lightening arrestor with aluminium strip 25mm x 3mm size including finial and grounding aluminium strip to be embeded in one of the columns in and independent GI conduit of 40mm dia. pipe suitably jointed by collars with all specials with all lead and lifts etc. complete for For Over Head Tanks upto 15M staging PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 7.7.4 Page No.87

1

14305

14305.67

... More
code106 - Providing and fixing DIperCI puddle flanges conforming to IS 7181-1986 with latest ammendments. in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For double flanged CI pipes of 80mm dia. PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 7.5.1 Page No.86

3

1627

4882.2

... More
code107 - Providing and fixing DIperCI puddle flanges conforming to IS 7181-1986 with latest ammendments. in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For double flanged CI pipes of 100mm dia. PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 7.5.2 Page No.86

2

1916

3833.66

... More
code108 - Providing Laying and Jointing Cast Iron CI double flanged pipes true to line per hoisting of DI flanged pipe in position and aligning to correct plumb including cost of jointing materials conveying to work spot with all lead and lifts etc complete. For double flanged CI pipes of 80mm dia. PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 7.6.1 Page No.86

20

2312

46247

... More
code109 - Providing Laying and Jointing Cast Iron CI double flanged pipes true to line per hoisting of DI flanged pipe in position and aligning to correct plumb including cost of jointing materials conveying to work spot with all lead and lifts etc complete. For double flanged CI pipes of 100mm dia. PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 7.6.2 Page No.86

20

3100

62006

... More
code110 - Providing and fixing 40mm dia. GI pipe medium duty pipes hand railing 3 rows fixed to RCC 1 2 4 vibrated post of 150x150mm at bottom and 100x150mm at top placed at 2 Mtrs. intervals for a height of 750mm including curing painting GI pipes with two coats of anticorrosive steel paint over a primer coat etc. with all lead lift etc. The rate per meter is for 3 rows of GI pipes and RCC post PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 7.8 Page No.87

24.1934

1366

33067.781054

... More
code111 - Construction of valve chambers Rate as per calculations of Valve Chambers in Pipeline estimation sheet

5

24526

122630

... More
code112 - Raising main Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications including setting out construction of shoring strutting barricading caution lights bracing using sight rails and boning rods at every 100 mm whevere necessary as directed removal of stumps and other deleterious matter dressing of sides and levelling the bottom of trench to the extent required utilising the available excavated earth locally for the work etc. and all other appurtenances complete in the following strata. In all kinds of soil depth upto 1.5m PWD SR 2023-24 Vol-I P-10 Sl-1.17.1

350

269

94451

... More
code113 - Earth work excavation for pipeline trenches by mechanical means above 600 mm trench width as per drawing and technical specifications including setting out construction of shoring strutting barricading caution lights bracing using sight rails and bonding rods at every 100 mm whevere necessary as directed removal of slumps and other deleterious matter dressing of sides and levelling the bottom of trench to the extent required utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Ordinaryorsoft rock without requiring blasting Depth upto 1.50 m PWD SR 2023-24 Vol-I P-10 Sl-1.19.1

100

467

46762

... More
code114 - Earth work excavation for pipeline trenches by mechanical means above 600 mm trench width as per drawing and technical specification including setting out construction of shoring strutting cost of blasting materialsbarricading caution lights bracing using sight rails and boning rods at every 100 mm whevere necessary as directed removal of slumps and other deleterious matter dressing of sides and levelling the bottom of trench to the extent required utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Hard rock blasting prohibited Depth upto 1.50 m PWD SR 2023-24 Vol-I P-11 Sl-1.21.5

50

1044

52221

... More
code115 - Providing and Filling in foundation with granite or trap broken metal 100mm. and down size and with approved sand ncluding hand packing ramming watering including cost of all materials and labour with all lead and lift complete as per specifications PWD SR 2023-24 Vol-I P-11 Sl-1.23

75

2762

207184.5

... More
code116 - Providing laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches laying true to line and jointing of pipes and specials with electrofusion welding giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee stub ends flanged sets bedns reducers etc. complete Contractor will make his own arrangements for procuring water for testing etc. complete. NOTE Upto 110mm dia Coil shall be used. For HDPE PE 100 PN 16.0 PWD SR 2023-24 Vol-V P-104 Item no. 9.14.2

1000

530

530450

... More
code117 - Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour all lead and lift including encasing the Specials around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. 90 mm Electro FusionCoupler PWD SR 2023-24 Vol-V P-104 Item no. 9.17.29

10

237

2379.3

... More
code118 - Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour all lead and lift including encasing the Specials around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc.. 90 mm Electro Fusion Elbow PWD SR 2023-24 Vol-V P-104 Item no. 9.17.35

10

466

4665.9

... More
code119 - Refilling available earth around trenchesorpipelines cables in layers not exceeding 20 cms in depth compacting each deposited layer by ramming after watering with a lead upto 50 m and lift upto 1.5 m. Including cost of all labour complete as per specifications PWD SR 2023-24 Vol-I P-7 Sl-1.10

375

164

61800

... More
code120 - Supply and fixing of Single or Double chamber triple function tamper proof Both the orifces to be housed in the single chamber Air valves with Body and cover in Ductile cast iron of grade GGG 40or50. All internal parts such as float shell with appurtenances. all cover bolts of austenitic alloy or SS 304 steel DN 50 float of HOSTAFLON or SS 304 and gaskers and seals of EPDM. Epoxy powder coating EP-P inside and outside colour blue RAL5005. The valves should be designed for all the three functions i.e. 1. Large orifice for venting of large air volumes on start up. 2. Large orifice for intake of large air volumes. 3. Small orifice for discharge of pressurized air during operation. For PN 10.0 For TP Air Valves of 50mm dia. PWD SR 2023-24 Vol-5 P-22 Item no.-2.35.1

4

29036

116146.92

... More
code121 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron DI conforming to IS-1865 and of grade GGG 40or50 shaft of stainless steel wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings minimum 2 “ O “ rings. Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves T.P set galvanized bolts and nuts and rubber insertions etc. but excluding earth work. Note TP set should be considered only for DI pipes estimate. For MS pipes estimates TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate. For PN-10. For Suilce Valve of PN-10.0 and 50mm PWD SR 2023-24 Vol-5 P-22 Item no.-2.23.1

3

5701

17103.15

... More
code122 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron DI conforming to IS-1865 and of grade GGG 40or50 shaft of stainless steel wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings minimum 2 O rings. Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves T.P set galvanized bolts and nuts and rubber insertions etc. but excluding earth work. Note TP set should be considered only for DI pipes estimate. For MS pipes estimates TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate. For PN-10. For Suilce Valve of PN-10.0 and 100mm PWD SR 2023-24 Vol-5 P-28 Item no.-2.23.5

2

11210

22421.04

... More
code123 - Supply and delivery of Centrifugal pump set at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 15 HP size 80x65 Head 44M Discharge 900 LPM PWD SR 2023-24 Vol-V P-157 Sl-13.40.12

2

55586

111172.02

... More
code124 - Providing and laying Ductile Iron pipes of class-conforming to IS 83292000 with latest amendments conveyiing to work site rolling and lowering into trenches laying true to line level and perfect linking at joints testing and commissioning including loading and unloading at both destinations cutting of pipes wherever necessary jointing with DI specials excluding cost of specials and rubber gaskets cleaning the socket and spigot end with soap solution applying soft soap to the socket and spigot ends before insertion of rubber gaskets jacking and fixing in perfect conditions etc. The cost to include soap solution soft soap waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. The contractor will make his own arrangements for water for testing. Earth work excavation in trenches to be measured and paid for seperately Note In sewerage projects for internal cement mortal lining CML of DI pipes if High Alumina Cement HAC as recommended in Annexure B clause 16.3 of IS83292000 is considered in place of Slag or Sulphate Resistance Cement SRC the cost of pipes may be increased by 5-6percentage from the prices listed. For DI K9 pipes. DI K9 150mm dia pipes PWD SR 2023-24 Vol-V P-52 Sl-4.2.2

20

2442

48842.6

... More
code125 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron DI conforming to IS-1865 and of grade GGG 40or50 shaft of stainless steel wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings minimum 2 “ O “ rings. Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves T.P set galvanized bolts and nuts and rubber insertions etc. but excluding earth work. Note TP set should be considered only for DI pipes estimate. For MS pipes estimates TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate. For PN-10. For Suilce Valve of PN-10.0 and 150mm PWD SR 2023-24 P-22 Item no. 2.23

2

18014

36029.4

... More
code126 - Supply and fixing of Cast steel ASTM A 216 Gr.WCB double flanged Dual plate check valve Conforming to API 594 with latest amendments Shaft material shall be SS420or431 and spring shall be spring steel uperior grade quality as detailed below of following diameters and types and conveying to work site loading unloading stacking with appurtenances. complete with all lead and lift. The rates are inclusive of cost of Galvanised Bolts and Nuts For Class 150 PWD SR 2023-24 P-24 Sl-2.26.3

3

8215

24645.84

... More
code127 - Labour charges for Erection Electrification and commissioning of Pump sets including aligning and balancing of all items including supply and erection of two pair of supporting clamps bore well caps cable clips and water tight gland cable protectors bolts nuts valve and gaugestools and equipments etc. involved in the job as per specifications with necessary tests as per specifications with testing of as per instructions of engineer incharge of work PWD SR 2023-24 P-156 Sl. No. 13.32

2

6695

13390

... More
code128 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m PWD SR 2023-24 Vol-I P-8 Sl-1.14.1

12.88

105

1353.1728

... More
code129 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In ordinaryorsoft rock without blasting up to 1.5 m depth PWD SR 2023-24 Vol-I P-8 Sl-1.15.1

3.68

373

1375.9152

... More
code130 - Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including cost of explosives dressing of excavated surfaces disposing off or levelling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour blasting materials tools usage of Machinery and all other appurtenaces required to complete the work In Hard Rock requiring blasting Depth upto 1.5 m PWD SR 2023-24 Vol-I-P-9 Sl-1.16.1

1.84

570

1049.9408

... More
code131 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machineries curing and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement and formwork shall be paid separately Mix 136 M10 Using 40 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 VOL-I Sl. 2.1.3 or Page No. 15

2.4

6168

14804.808

... More
code132 - Providing and laying in position Reinforced cement concrete for all Foundation works. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers well compacted using needle vibrators including all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement and formwork to be paid separately M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 Vol-I P-15 Sl-2.2.1

7.24

6799

49227.5836

... More
code133 - Supplying fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials machinery labour cleaning straightening cutting bending hooking lapingorwelding joints tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures PWD SR 2023-2024 Item No. VOL-I-2.11.h Page No.18

0.362

81381

29460.04146

... More
code134 - Filling available excavated earth excluding rock in trenches plinth sides of foundations and other similar works etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m. PWD SR 2023-24 Vol-I P-7 Sl-1.9

3.04

273

832.8992

... More
code135 - Borewell Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S by vertical electrical sounding by adopting Venner or Schlumbergers’s method including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity its quality quantity and acceptability of the users indicating the location of the site recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe depth of drilling required to cover full depth of aquifer proposed to be tapped probable yield and other information required including transportation of instruments and accessories to work site engaging technical personal and labour required etc. NOTE 1 Additional rate on item 1and2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M for fixing Casing pipes only a Above 20 M and upto 30 M-15percentage b Above 30 M-30percentage Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level. 2 A sum of Rs. 100or-is to be deducted for Dry Borewell towards yield test. PWD SR 2023-24 Vol-5 Pg-140 Sl.No.-12.4

2

5446

10893.28

... More
code136 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG and above 1100 CMF and above in all strata including over burdern upto 20 m. Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc. complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc. complete Borewell depth of 0 to 50 m PWD SR 2023-24 Vol-5 Pg-139 Sl.No.-12.1.1

100

381

38110

... More
code137 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG and above 1100 CMF and above in all strata including over burdern upto 20 m. Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc. complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc. complete Borewell depth of 50 to 100 m PWD SR 2023-24 Vol-5 Pg-139 Sl.No.-12.1.2

100

477

47792

... More
code138 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG and above 1100 CMF and above in all strata including over burdern upto 20 m. Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc. complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc. complete Borewell depth of 100 to 150 m PWD SR 2023-24 Vol-5 Pg-139 Sl.No.-12.1.3

100

507

50779

... More
code139 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG and above 1100 CMF and above in all strata including over burdern upto 20 m. Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc. complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc. complete Borewell depth of 150 to 200 m PWD SR 2023-24 Vol-5 Pg-139 Sl.No.-12.1.4

100

589

58916

... More
code140 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG and above 1100 CMF and above in all strata including over burdern upto 20 m. Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc. complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc. complete Borewell depth of 200 to 250 m PWD SR 2023-24 Vol-5 Pg-139 Sl.No.-12.1.5

100

691

69113

... More
code141 - Supply of ISI mark 175mm nominal boreplain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments electrical resistance welded steel tubes material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kgorm.prices include Collar-Medium duty. PWD SR 2023-24 Vol-5 Pg-143 Sl.No.-12.32

200

1990

398198

... More
code142 - Providing and fixing MS casing collars as per IS 1239 part-II 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm minimum. The dimensions of caps and colars shall be strictly as per IS 1239 Part-II 1982 with all amendments PWD SR 2023-24 Vol-5 Pg-143 Sl.No.-12.33

4

154

618

... More
code143 - Providing and laying at site of work MS casing caps as per IS 1239 part-II 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm minimum. The dimensions of caps and colars shall be strictly as per IS 1239 Part-II 1982 with all amendments including cost of material and labour charges for fixing if any etc. complete with all lead and lifts and as directed by the Engineer in charge PWD SR 2023-24 Vol-5 Pg-143 Sl.No.-12.34

2

168

337.84

... More
code144 - Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-000 3Phase SS Bowl and Impeller with Low volt Motor as per specifications to work site as per necessary ammendments and instructions of engineer incharge of work. For 10.00 HP-90 LPM at 220 m equal to 20 STG Outlet Dia-2.00 PWD SR 2023-24 Vol-5 Pg-152 Sl.No.-13.16.7

2

57342

114685.2

... More
code145 - Labour charges for Erection Electrification and commissioning of Pump sets including aligning and balancing of all items including supply and erection of two pair of supporting clamps bore well caps cable clips and water tight gland cable protectors bolts nuts valve and gaugestools and equipments etc. involved in the job as per specifications with necessary tests as per specifications with testing of as per instructions of engineer incharge of work. PWD SR 2023-24 Vol-5 Pg-156 Sl.No.-13.32

2

6695

13390

... More
code146 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to138130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-6942010.-3C x 6 mm2 Two cables PWD Electrical SR-2023-24 Vol-6 Item No.2.6.3 Page No.7

200

252

50470

... More
code147 - Supply installingtesting and commissioning COMMON control panel consisting of the following INCOMING1 No set of Phase indicating lamps with SFU of suitable rating 1 No Analog Ammeter 1 No Analog Voltmeter 1ni with Phase selector switch Isolating switch OUTGOING for Main Electrical Pump 1 No. MCB 1 No. DOL of SorD Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor under voltage over Volage under current over current and dry run protection suitable for the pump described above 1 no Indoor typ e NOTE 1 DOLDirect Online Starter 2 S-D-Star Delta Starter 6 to 15 HP pumps PWD SR 2023-24 Vol-5 Pg-155 Sl.No.-13.23.3

2

16377

32754

... More
code148 - Supplying fixing and Single phase preventer using necessary wires over an existing panel board suitable for motor up to 20HP capacities. PWD Electrical SR-2023-24 Vol-6 Item No.5.3 Page No.14

4

931

3724.56

... More
code149 - Suplying fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase 400or440 volts grade for power factor improvement of roating machineries like induction motor PWD Electrical SR-2023-24 Vol-6 Item No.5.37 Page No.19

4

494

1977.6

... More
code150 - Supplying and fixing of Porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts bolts and washers. 32 Amps PWD Electrical SR-2023-24 Vol-6 Item No.5.7.2age No.14

4

248

992.92

... More
code151 - Providing Laying and Fixing GI pipes conforming to IS 12391990 with latest amendments complete with GI fittings excluding the cost of fittings with cuts and threads wherever necessary including testing for water tightness with all lead and commissioning. contractor will make his own arrangements for procuring water for testing For Medium Duty GI pipe of 50mm dia PWD SR 2023-24 Vol-5 Pg-127 Sl.No.-11.3.6

300

699

209811

... More
code152 - Labour charges for laying and jointing GI pipes with earth work including fixing collars elbows tees bends gland cocks and other fittings with cuts and threads white lead paints wherever necessary conveying the materials from office to workspot and retuning the surplus materials from workspot to stores for 50mm dia. GI pipes and specials. PWD SR 2023-24 Vol-5 Pg-15 Sl.No.-2.6.5

300

32

9888

... More
code153 - Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 20x20x2.5 P.W.D. Electrical-2022-23 Item No.5.6.6 Page No.24 PWD Electrical SR-2023-24 Vol-6 Item No.5.6.6.2age No.14

2

335

671.82

... More
code154 - Yield testing of borewells at final depth with a minimum of 10 hours continuously with the help of pump testing unit including the cost of transportation charges crew charges and cost of consumables. PWD SR 2023-24 Vol-5 Pg-140 Sl.No.-12.9

2

16795

33590.36

... More
code155 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality screwed end 65 mm nominal bore PWD SR 2023-24 Vol-2 Pg-117 Item no. 13.4.5

2

1453

2906.66

... More
code156 - Providing and fixing gun metal non-return valve of approved quality screwed end 50 mm nominal bore Horizontal PWD SR 2023-24 Vol-2 Pg-118 Item no. 13.6.4.1

2

1401

2803.66

... More
code157 - Pump house Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.14.1 Page No.8

29.176

105

3065.23056

... More
code158 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work. In ordinarypersoft rock without blasting upto 1.5 m depth Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.15.1 Page No.8

8.336

373

3116.74704

... More
code159 - Earth work excavation for Foundation by mechanical means for all works and depth upto 1.5 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In Hard Rock requiring blasting Depth upto 1.50m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.16.1 Page No.9

4.168

570

2378.34416

... More
code160 - Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1 6 1 cement 6 coarse sand PWD SOR for Buildings - 2023-24 Item No. VOL-II-5.4 Page No.9

6.53

6580

42971.7751

... More
code161 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1 6 1 cement 6 coarse sand including cost of all materials labour scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. PWD SOR for Buildings - 2023-24 Item No. VOL-II-6.8 Page No.14

14.563

8208

119534.12341

... More
code162 - Providing MathiperNandi wood frames of doors windows clerestory windows ventilators and other frames wrought framed or assembled including making plaster groves excluding cost of cement concrete and side clamps but including cost of materials labour usage charges complete as per specifications. PWD SOR for Buildings - 2023-24 Item No. VOL-II-12.12 Page No.99

0.08

127928

10234.2448

... More
code163 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1 3 6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials labour charges complete as per specifications PWD SOR for Buildings - 2023-24 Item No. VOL-II-12.51 Page No.104

1

1046

1046.48

... More
code164 - Providing and fixing in position fully panelled MattiperNandi wood shutters for doors with stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials labour usage charges complete as per specifications. excluding cost of fixtures PWD SOR for Buildings - 2023-24 Item No. VOL-II-12.18 Page No.100

1.89

6773

12801.4992

... More
code165 - Supplying and fixing rolling shutters of approved make made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. PWD SOR for Buildings - 2023-24 Item No. VOL-II-11.16.1 Page No.78

7.5

2711

20339.925

... More
code166 - Providing and fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC Matching to RAL-9016 sections and with minimum TiO2 Titanium Dioxide at 6 PHR with TPE Thermo Plastic Elastomer and lead free gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass standard hardwareand single . locking system with Crescent Locks. Wall thickness of frame and sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. The cost is inclusive of all fixtures and separate charges for minor TandP s shall not be made PWD SOR for Buildings - 2023-24 Item No. VOL-II-12.84 Page No.109

6.15

5173

31818.1935

... More
code167 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings perwooden frames with rawl plugs screws etc. PWD SOR for Buildings - 2023-24 Item No. VOL-II-11.34B Page No.15.1

79.95

188

15069.7755

... More
code168 - Providing 12 mm cement plaster with cement mortar 1 6 1 cement 6 fine sand including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineer-in-charge. PWD SOR for Buildings - 2023-24 Item No. VOL-II-8.1.2 Page No.41

109.71

248

27233.3133

... More
code169 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1 5 1 cement 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 1 6 1 cement 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineer-in-charge PWD SOR for Buildings - 2023-24 Item No. VOL-II-8.8 Page No.42

119.95

382

45836.4935

... More
code170 - Providing and laying flooring with burnt stone slabs 10 cms thick rough chistle dressed on cement mortar bed 1 6 25 mm thick and .ed with cement mortar 1 3 including cost of materials mortar labour curing complete as per specifications. PWD SOR for Buildings - 2023-24 Item No. VOL-II-9.27 Page No.63

29

2459

71329.56

... More
code171 - Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work two coats over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer-in-charge PWD SOR for Buildings - 2023-24 Item No. VOL-II-8.25 Page No.45

109.71

141

15481.1781

... More
code172 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer-in-charge PWD SOR for Buildings - 2023-24 Item No. VOL-II-8.39 Page No.48

109.71

130

14351.1651

... More
code173 - Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer-in-charge. PWD SOR for Buildings - 2023-24 Item No. VOL-II-8.27 Page No.45

119.95

54

6548.0705

... More
code174 - Finishing walls with water proofing cement paint of required shade New work Two coats applied at 4.84 kgper10 m² to give an even shade after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer-in-charge. PWD SOR for Buildings - 2023-24 Item No. VOL-II-8.28 Page No.45

119.95

91

10995.8165

... More
code175 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer-in-charge. PWD SOR for Buildings - 2023-24 Item No. VOL-II-8.41 Page No.48

13.65

172

2347.9365

... More
code176 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terraceperChajjasperSunken portion of WC Bathroom cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percentage and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6 kgperm2 to achieve final DFT Dry Film Thickness of 1mm including prime coat of epoxy primer at150 gperm2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation making coving at Junction Bore Packing treatment of construction joints completely as per specification. PWD SOR for Buildings - 2023-24 Item No. VOL-II-15.1 Page No.149

24.35

841

20490.7685

... More
code177 - Providing and Filling in foundation with granite per trap broken metal 100mm. and down size and with approved sand including hand packing ramming watering including cost of all materials and labour with all lead and lift complete as per specifications. Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.23 Page No.11

4.58

2762

12652.0668

... More
code178 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. Mix 1 3 6 Using 40 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.1.3 Page No.15

8.83

6168

54469.3561

... More
code179 - Providing and laying in position Cement Concrete for all Foundation works. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers well compacted using needle vibrators including all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.2.1 Page No.15

5.65

6993

39514.1225

... More
code180 - Providing and laying in position Cement Concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators. The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.5.1 Page No.16

2.55

10243

26120.5425

... More
code181 - Providing and laying in position Cement Concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators. The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.5.1 Page No.16

1.29

11609

14975.7777

... More
code182 - Providing and laying in position Cement Concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators. The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.5.1 Page No.16

2.25

10926

24584.04

... More
code183 - Providing and laying in position Cement Concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators. The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.5.1 Page No.16

3.65

10243

37388.2275

... More
code184 - Providing and laying in position Cement Concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height. The granitepertrapperbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators. The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.5.1 Page No.16

1.08

9901

10694.052

... More
code185 - Supplying fitting and placing TMT FE 550 per 550D Steel Reinforcement including cost of all materials machinery labour cleaning straightening cutting bending hooking lapingperwelding joints tying with binding wire per soft nnealed steel wire and other ancilary operations complete as per drawing and technical specification. For Buildings Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.11.a Page No.18

1.98

92140

182438.6058

... More
code186 - Filling approved earth excluding rock in trenches plinth sides of foundations and other similar works etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m. Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.11 Page No.7

31.37

445

13990.7063

... More
code187 - UGD Refilling available earth around trenchesperpipelines cables in layers not exceeding 20 cms in depth compacting each deposited layer by ramming after watering with a lead upto 50 m and lift upto 1.5 m. Including cost of all labour complete as per specifications Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.10 Page No.7

4730.339

164

779559.8672

... More
code188 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications including setting out construction of shoring strutting barricading caution lights bracing using sight rails and boning rods at every 100 mm whevere necessary as directed removal of stumps and other deleterious matter dressing of sides and levelling the bottom of trench to the extent required utilising the available excavated earth locally for the work etc. and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.17.1 Page No.10

2230.661

269

601966.17746

... More
code189 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications including setting out construction of shoring strutting barricading caution lights bracing using sight rails and boning rods at every 100 mm whevere necessary as directed removal of stumps and other deleterious matter dressing of sides and levelling the bottom of trench to the extent required utilising the available excavated earth locally for the work etc. and all other appurtenances complete in the following strata. All kinds of soils. Depth exceeding 1.5 m but not exceeding 3 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.17.2 Page No.10

1180.774

340

402561.27982

... More
code190 - Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifications including setting out construction of shoring strutting barricading caution lights bracing using sight rails and bonding rods at every 100 mm whevere necessary as directed removal of slumps and other deleterious matter dressing of sides and levelling the bottom of trench to the extent required utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Ordinarypersoft rock without requiring blasting Depth upto 1.50 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.19.1 Page No.10

637.331

467

298028.72222

... More
code191 - Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifications including setting out construction of shoring strutting barricading caution lights bracing using sight rails and bonding rods at every 100 mm whevere necessary as directed removal of slumps and other deleterious matter dressing of sides and levelling the bottom of trench to the extent required utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Ordinarypersoft rock without requiring blasting Depth exceeding 1.5 m but not exceeding 3 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.19.2 Page No.10

337.364

573

193549.10044

... More
code192 - Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specification including setting out construction of shoring strutting cost of blasting materials barricading caution lights bracing using sight rails and bonding rods at every 100 mm wherever necessary as directed removal of stumps and other deleterious matter dressing of sides and levelling the bottom of trench to the extent required utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Hard rock requiring blasting Depth upto 1.50 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.21.1 Page No.10

318.666

689

219583.18062

... More
code193 - Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specification including setting out construction of shoring strutting cost of blasting materials barricading caution lights bracing using sight rails and bonding rods at every 100 mm wherever necessary as directed removal of stumps and other deleterious matter dressing of sides and levelling the bottom of trench to the extent required utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Hard Rock Depth exceeding 1.5 m but not exceeding 3 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.21.2 Page No.10

168.682

774

130654.32992

... More
code194 - Providing and installation of Class SN8 Double Wall Corrugated HDPE pipe 100 mm dia outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour all lead and lift including encasing the pipe around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. complete. PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 9.16.1 Page No.106

498

291

145162.02

... More
code195 - Providing and installation of Class SN8 Double Wall Corrugated HDPE pipe 150 mm dia outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour all lead and lift including encasing the pipe around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. complete. 2023-24 Item No. VOL-5 - 9.16.3 Page No.106

1448

485

702468.24

... More
code196 - Providing and constructing of Machinehole chambers conical in shape at top with CC 1 3 6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1 4 plaster with bricks of approved quality and CM plaster 1 3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick with 1 to 6 slope in the concrete towards the central drain finished smooth and fixing of pipes in CC 1 2 4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592 Part-I 1988 and IS 12592 Part-II 1991 with latest amendments in CC 1 2 4 Providing and fixing of plastic foot steps staggered at 30cms apart as directed watering curing barricading danger lighting pouring tar over M.H. frame and cover cost of tar shoring strutting dewatering engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. WithTable Moulded Bricks Machinehole 1.2 m internal dia. 1.0 M depth and Heavy duty SFRC cover and frame PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 16.46.1 Page No.204

12

25748

308987.64

... More
code197 - Providing and constructing of Machinehole chambers conical in shape at top with CC 1 3 6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1 4 plaster with bricks of approved quality and CM plaster 1 3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick with 1 to 6 slope in the concrete towards the central drain finished smooth and fixing of pipes in CC 1 2 4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592 Part-I 1988 and IS 12592 Part-II 1991 with latest amendments in CC 1 2 4 Providing and fixing of plastic foot steps staggered at 30cms apart as directed watering curing barricading danger lighting pouring tar over M.H. frame and cover cost of tar shoring strutting dewatering engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. WithTable Moulded Bricks Machinehole 1.2 m internal dia. 2.0 M depth and Heavy duty SFRC cover and frame PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 16.46.2 Page No.204

13

48519

630749.34

... More
code198 - Providing and constructing of Machinehole chambers conical in shape at top with CC 1 3 6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1 4 plaster with bricks of approved quality and CM plaster 1 3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick with 1 to 6 slope in the concrete towards the central drain finished smooth and fixing of pipes in CC 1 2 4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592 Part-I 1988 and IS 12592 Part-II 1991 with latest amendments in CC 1 2 4 Providing and fixing of plastic foot steps staggered at 30cms apart as directed watering curing barricading danger lighting pouring tar over M.H. frame and cover cost of tar shoring strutting dewatering engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. WithTable Moulded Bricks Machinehole 1.2 m internal dia. 3.0 M depth and Heavy duty SFRC cover and frame PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 16.46.3 Page No.204

2

73879

147759.68

... More
code199 - Providing and constructing of Machinehole chambers conical in shape at top with CC 1 3 6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1 4 plaster with bricks of approved quality and CM plaster 1 3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick with 1 to 6 slope in the concrete towards the central drain finished smooth and fixing of pipes in CC 1 2 4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592 Part-I 1988 and IS 12592 Part-II 1991 with latest amendments in CC 1 2 4 Providing and fixing of plastic foot steps staggered at 30cms apart as directed watering curing barricading danger lighting pouring tar over M.H. frame and cover cost of tar shoring strutting dewatering engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. WithTable Moulded Bricks Machinehole 1.5 m internal dia. 3.0 M depth and Heavy duty SFRC cover and frame PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 16.48.3 Page No.204

15

87719

1315799.25

... More
code200 - Providing and constructing of Machinehole chambers conical in shape at top with CC 1 3 6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1 4 plaster with bricks of approved quality and CM plaster 1 3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick with 1 to 6 slope in the concrete towards the central drain finished smooth and fixing of pipes in CC 1 2 4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592 Part-I 1988 and IS 12592 Part-II 1991 with latest amendments in CC 1 2 4 Providing and fixing of plastic foot steps staggered at 30cms apart as directed watering curing barricading danger lighting pouring tar over M.H. frame and cover cost of tar shoring strutting dewatering engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. WithTable Moulded Bricks Machinehole 1.5 m internal dia. 4.0 M depth and Heavy duty SFRC cover and frame PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 16.48.4 Page No.204

10

120902

1209024.3

... More
code201 - Digester 10 KLD Waste Water Treatment by Prefabricated anaerobic Bio Septic tank For 100 Soulsper10KLD Providing installation and commissioning of an anaerobic Bio Septic tank with all necessary accessories such as pre-filter pipes prefabricated RCC Tank including internal matrix for enhanced growth of Bacteria Anaerobic microbial Inoculum developed by DRDO and baffle wall to control the flow of water and to increase the retention time in the RCC Tank Note Refer to technical specification attached as Annexure-1 including cost of material loading and unloading and as directed by the Engineer in charge etc. complete including annual maintenance of the system for 5 years. Note - 1. Above rates mentioned are for the purpose of preparation of estimate only. 2. All items are of ISI standards. 3. After commissioning of plant necessary testing to be done for the satisfaction of the engineer in charge. 4. Design drawing of the system suitable for erection is given in figures PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 22.1 Page No.251

3

927000

2781000

... More
code202 - Rain Water Harvesting Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.14.1 Page No.8

35.63

105

3743.2878

... More
code203 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work. In ordinarypersoft rock without blasting. Depth exceeding 1.5 m but not exceeding 3 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.15.2 Page No.8

10.18

437

4456.295

... More
code204 - Earth work excavation for Foundation by mechanical means for all works and depth upto 1.5 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In Hard Rock requiring blasting Depth exceeding 1.5 m but not exceeding 3 m Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-1.16.2 Page No.9

5.09

641

3266.2021

... More
code205 - Providing and laying in Cement Concrete for all Basement and surface level works return walls retaining walls sunken floors etc. The granitepertrapper basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators providing weep holes wherever necessary including all lead and lifts cost of all materials of quality labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.3.1 Page No.16

1.696

6838

11597.79072

... More
code206 - Supplying fitting and placing TMT FE 550 per 550D Steel Reinforcement including cost of all materials machinery labour cleaning straightening cutting bending hooking lapingperwelding joints tying with binding wire per soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I-2.11.h Page No.18

0.135

81381

10986.47955

... More
code207 - Stone Aggregate-40 mm down size Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I Sl. No.7 Page No.A-42

13.573

1225

16636.4261

... More
code208 - Stone Aggregate-20 mm down size Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I Sl. No.4 Page No.A-42

13.573

1372

18635.59327

... More
code209 - Stone Aggregate-6 mm down size Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I Sl. No.1 Page No.A-42

13.573

1452

19712.0679

... More
code210 - Labour charges for Mazdoor Unskilled for Zone-III Common SOR For Engineering Departments 2023 - 2024 Item No. VOL-I Sl. No.IV Page No.A-50

5

504

2521.05

... More
code211 - Supplying of RCC perforated rings - 1200 mmx1250 mm PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 693 Page No.A-45

45

7210

324450

... More
code212 - Providing to work spot rolling lowering and placing in position RCC perforated rings in the already excavated pit including loading and unloading at both the destinations with all lead and lift with appurtenances. complete. 1200 mmx1250 mm PWD SOR for Water Supply and Sewerage Works - 2023-24 Item No. VOL-5 - 16.62 Page No.208

45

9830

442364.4

... More
code213 - Electrical works PART-A Providing 2 Pole Structrue at the Tapping. Using RCC Pole-13 NOS near KPTCL SUBSTION-1 Main Tapping .s-1 ckts 1 rmu 250 KVA TC YARD-10 NOS Supply of DP Structure using RCC Pole - 9 Mtr Long 145 Kg WL Including Cost of Poles

12

21555

258670.08

... More
code214 - Fixing of DP Structure using RCC Pole - 9 Mtr Long 145 Kg WL Including Cost of Poles

12

5533

66397.92

... More
code215 - Supply of 11 kV 45 KN Polymeric Insulator

72

191

13793.76

... More
code216 - Supply of Guy Set Complete with No. 15 Strain Insulator

24

1205

28922.4

... More
code217 - Laying of Guy Set Complete with No. 15 Strain Insulator

24

610

14658.96

... More
code218 - Supply of Spiral Earth Electrode

24

246

5908.08

... More
code219 - Fixing of Spiral Earth Electrode

24

95

2298.96

... More
code220 - Laying of Guy concreting with Boulders Mud and Sand

24

257

6180

... More
code221 - Supply of CautionperDanger Board

12

154

1854

... More
code222 - Fixing of CautionperDanger Board

12

82

988.8

... More
code223 - Supply of Anti Climbing Device 12 Mtr GI Barbed Wire

24

91

2200.08

... More
code224 - Fixing of Anti Climbing Device 12 Mtr GI Barbed Wire

24

43

1038.24

... More
code225 - Supply of 11 kV 400 Amps Double Break GOS

12

21897

262773.6

... More
code226 - Fixing of 11 kV 400 Amps Double Break GOS

12

1250

15005.04

... More
code227 - Supply of H-Frame for mounting GOS

12

4461

53543.52

... More
code228 - Fixing of H-Frame for mounting GOS

12

332

3992.28

... More
code229 - Supply of DOLO Cut Out Set per 3 Nos

12

6048

72577.92

... More
code230 - Fixing of DOLO Cut Out Set per 3Nos

12

244

2929.32

... More
code231 - Concreting Material for 9mtrs RCC Poles structure.base concreting cc 1 4 8 500x650x150mm. ESCOM SR 2023-24 volume-6 CDS-28

24

321

7712.64

... More
code232 - pole concreting cc 1 2 4 650x500x1700mm. ESCOM SR 2023-24 volume-6 CDS-28

24

4629

111116.4

... More
code233 - providing coping for poles with cc 1 2 4 and as per norms. ESCOM SR 2023-24 volume-6 CDS-28

24

321

7712.64

... More
code234 - Supply and Fixing of GI Wire 8 SWG. ESCOM SR 2023-24 volume-6 CDS-24

24

77

1854.96

... More
code235 - PART-B Laying of 11 kV 3x240 Sqmm XLPE UG Cable Using Conventional Laying with Excavation in Soil Supply of 11kV 3x240 Sqmm XLPE UG Cable. ESCOM SR 2023-24 volume-6 CDS-21

0.1

1705729

170572.944

... More
code236 - Supply of Straight Through Jointing Kits HS Type suitable for 3x240 Sqmm Cable. ESCOM SR 2023-24 volume-6 CDS-21

2

9075

18150.66

... More
code237 - Supply of Cable termination kit Outdoor HS Type Suitable for 3x240 Sqmm Cable. ESCOM SR 2023-24 volume-6 CDS-21

6

5477

32865.24

... More
code238 - Supply of Cable termination kit Indoor HS Type Suitable for 3x240 Sqmm Cable. ESCOM SR 2023-24 volume-6 CDS-21

6

4831

28990.38

... More
code239 - Supply of Cable Covering Tiles 250x125x40 mm or 125x125x40 mm. ESCOM SR 2023-24 volume-6 CDS-21

500

5

2640

... More
code240 - Supply of ArtificialperManufacture Sand Extracted from Vol-1 PWD SR Sl No. 62 . ESCOM SR 2023-24 volume-6 CDS-21

2

1839

3679.16

... More
code241 - Supply of RCC Hume pipe 2000 mm Long 150 mm Dia. ESCOM SR 2023-24 volume-6 CDS-21

4

316

1264.84

... More
code242 - Supply of Collars for RCC Hume Pipe. ESCOM SR 2023-24 volume-6 CDS-21

4

84

337.84

... More
code243 - Supply of GI Pipe 100 mm Dia for drain crossing cable raising etc. Extracted from Vol-5 BWSSB SR Item No. 177 . ESCOM SR 2023-24 volume-6 CDS-21

50

1272

63602.5

... More
code244 - Supply of Route and Joint Indicating Stones. ESCOM SR 2023-24 volume-6 CDS-21

20

136

2739.8

... More
code245 - Cable trench excavation 1000x0.6x1equal to600 Ordinary soil Extracted from Vol-1 PWD SR Sl No. 1.17.1 . ESCOM SR 2023-24 volume-6 CDS-21

40

269

10794.4

... More
code246 - Laying of cable in trench. ESCOM SR 2023-24 volume-6 CDS-21

0.1

66077

6607.759

... More
code247 - Refilling and consolidation. Extracted from Vol-1 PWD SR Sl No. 1.10 . ESCOM SR 2023-24 volume-6 CDS-21

40

164

6592

... More
code248 - Making of straight through joint. ESCOM SR 2023-24 volume-6 CDS-21

2

2933

5866.88

... More
code249 - Making of cable termination. ESCOM SR 2023-24 volume-6 CDS-21

12

2737

32852.88

... More
code250 - Covering the cable with tile. ESCOM SR 2023-24 volume-6 CDS-21

0.1

4498

449.801

... More
code251 - Spreading Sand and forming with Sand round the cable. ESCOM SR 2023-24 volume-6 CDS-21

0.1

15254

1525.43

... More
code252 - Laying of RCC Hume pipe. ESCOM SR 2023-24 volume-6 CDS-21

4

71

284.28

... More
code253 - Laying of GI Pipe. ESCOM SR 2023-24 volume-6 CDS-21

50

95

4789.5

... More
code254 - Laying of Route and Joint indicating stone. ESCOM SR 2023-24 volume-6 CDS-21

20

119

2389.6

... More
code255 - PART-C Providing Compact RMU 11 kV Class SF6perVCB Type 1 Incomer Plus 1 Breaker Plus 1 Outgoing Supply of RMU 3 Way 2OD Plus 1VL One Incomer Plus One Breakers Plus One outgoing 350 MVA 630 Amps. ESCOM SR 2023-24 volume-6 CDS-33

1

566036

566036.5

... More
code256 - Bed Concreting with CC 1 2 4 M-15 Using 20mm Nominal size graded crushed coarse aggregates Extracted from Item No. 2.1.6 of KPWD SR 2023-24 Volume - 1 . ESCOM SR 2023-24 volume-6 CDS-33

0.08

6430

514.4232

... More
code257 - Foundation with CC 1 2 4 M-15 Using 20mm Nominal size graded crushed coarse aggregates Extracted from Item No. 2.1.6 of KPWD SR 2023-24 Volume - 1 . ESCOM SR 2023-24 volume-6 CDS-33

0.36

6430

2314.9044

... More
code258 - Providing Reinforecement TMT Fe 550per550 D Extracted from SL No. 69 of KPWD SR 2023-24 Volume - 1 . ESCOM SR 2023-24 volume-6 CDS-33

80

75

6015.2

... More
code259 - Providing Plinth with CC 1 2 4 on the Stone Masonary M-15 Using 20mm Nominal size graded crushed coarse aggregates Extracted from Item No. 2.1.6 of KPWD SR 2023-24 Volume - 1 . ESCOM SR 2023-24 volume-6 CDS-33

0.06

6430

385.8174

... More
code260 - Construction of Stone Masonary Extracted from Sl No. 5.4 of KPWD SR 2023-24 Volume - 3 . ESCOM SR 2023-24 volume-6 CDS-33

0.43

6580

2829.6881

... More
code261 - Supplying of Frame of MS Channel 100x50 mm and MS angle 40x40x5 mm welding etc. complete. Extracted from SL No. 69 of KPWD SR 2023-24 Volume - 1 . ESCOM SR 2023-24 volume-6 CDS-33

37.5

70

2626.5

... More
code262 - Lettering the RMU with enamel paint and also writing single line diagram of each panel caution Board Danger Board etc. including cost of Paint Brush etc. . ESCOM SR 2023-24 volume-6 CDS-33

1

989

989.83

... More
code263 - Earth Excavation for RMU Foundation depositing of earth on bank up to a lead of 50 Mtr and with a lift up to 1.5 Mtr. ESCOM SR 2023-24 volume-6 CDS-33

4.35

269

1173.891

... More
code264 - Labour charges for Fixing foundation frame of MS channel 100x50 mm and MS angle 40x40x5 mm welding fixing in concrete aligning the RMU on foundation bed assembly of units connecting Bus Bars from panel to panel etc. complete.. ESCOM SR 2023-24 volume-6 CDS-33

3

4919

14757.84

... More
code265 - PART-D Running Single Circuit 11 kV 3 Phase Power Line On 9 Mtr Supports With An Average Span Of 40 Mtr Using RABBIT ACSR Conductor 5KM+2.2KMequal to7.2KM Supply of RCC Pole - 9 Mtr Long 145 Kg WL. ESCOM SR 2023-24 volume-6 CDS-1

181

7288

1319178.68

... More
code266 - Fixing of RCC Pole - 9 Mtr Long 145 Kg WL. ESCOM SR 2023-24 volume-6 CDS-1

181

1794

324761.06

... More
code267 - Supply of 11 kV Horizontal Cross Arm with clamps HTST supports bolts nuts and washers for RCC Pole - 9 Mtr Long 145 Kg WL. ESCOM SR 2023-24 volume-6 CDS-1

181

665

120433.78

... More
code268 - Fixing of 11 kV Horizontal Cross Arm with clamps HTST supports bolts nuts and washers for RCC Pole - 9 Mtr Long 145 Kg WL. ESCOM SR 2023-24 volume-6 CDS-1

181

280

50708.96

... More
code269 - Supply of DP Structure with RCC Pole - 9 Mtr Long 145 Kg WL. ESCOM SR 2023-24 volume-6 CDS-1

10

21555

215558.4

... More
code270 - Fixing of DP Structure with RCC Pole - 9 Mtr Long 145 Kg WL. ESCOM SR 2023-24 volume-6 CDS-1

10

5553

55537.6

... More
code271 - Supply and Fixing of 11 kV 5 KN Polymeric Pin Insulator 24 mm Dia FRP Rod . ESCOM SR 2023-24 volume-6 CDS-1

543

211

114654.45

... More
code272 - Supply and Fixing of 11 kV 45 KN Polymeric Insulator. ESCOM SR 2023-24 volume-6 CDS-1

60

191

11494.8

... More
code273 - Supply of Guy Set Complete with No. 15 Strain Insulator. ESCOM SR 2023-24 volume-6 CDS-1

60

1205

72306

... More
code274 - Fixing of Guy Set Complete with No. 15 Strain Insulator. ESCOM SR 2023-24 volume-6 CDS-1

60

610

36647.4

... More
code275 - Supply of Rabbit ACSR Conductor. ESCOM SR 2023-24 volume-6 CDS-1

21.924

47621

1044043.24248

... More
code276 - Laying of Rabbit ACSR Conductor. ESCOM SR 2023-24 volume-6 CDS-1

21.924

4491

98478.88092

... More
code277 - Supply and Fixing of PG Clamps for Rabbit Conductor. ESCOM SR 2023-24 volume-6 CDS-1

42

105

4412.52

... More
code278 - Supply of Spiral Earth Electrode. ESCOM SR 2023-24 volume-6 CDS-1

168

246

41356.56

... More
code279 - Fixing of Spiral Earth Electrode. ESCOM SR 2023-24 volume-6 CDS-1

168

95

16092.72

... More
code280 - Supply of EG Stirrups with GI wire lacing. ESCOM SR 2023-24 volume-6 CDS-1 set per 2nos

168

284

47759.04

... More
code281 - Fixing of EG Stirrups with GI wire lacing. ESCOM SR 2023-24 volume-6 CDS-1 set per 2nos

168

164

27686.4

... More
code282 - Supply Laying of Guy concreting with Boulders Mud and Sand. ESCOM SR 2023-24 volume-6 CDS-1

60

257

15450

... More
code283 - Supply of CautionperDanger Board. ESCOM SR 2023-24 volume-6 CDS-1

56

154

8652

... More
code284 - Fixing of CautionperDanger Board. ESCOM SR 2023-24 volume-6 CDS-1

56

82

4614.4

... More
code285 - Supply of Anti Climbing Device 12 Mtr GI Barbed Wire . ESCOM SR 2023-24 volume-6 CDS-1

42

91

3850.14

... More
code286 - Fixing of Anti Climbing Device 12 Mtr GI Barbed Wire . ESCOM SR 2023-24 volume-6 CDS-1

42

43

1816.92

... More
code287 - Supply of Guarding Material Rs. 93perMtr . ESCOM SR 2023-24 volume-6 CDS-5 .

20

4789

95790

... More
code288 - Fixing of Guarding Material Rs. 93perMtr . ESCOM SR 2023-24 volume-6 CDS-5 .

20

1858

37162.4

... More
code289 - Supply of 4 Pin Cross Arm with clamps bolts nuts and washers for guarding. ESCOM SR 2023-24 volume-6 CDS-5 .

20

432

8652

... More
code290 - Fixing of 4 Pin Cross Arm with clamps bolts nuts and washers for guarding. ESCOM SR 2023-24 volume-6 CDS-5 .

20

164

3296

... More
code291 - Supply of RCC Pole - 8 Mtr Long 115 Kg WL. ESCOM SR 2023-24 volume-6 CDS-3

40

5282

211314.8

... More
code292 - Fixing of RCC Pole - 8 Mtr Long 115 Kg WL. ESCOM SR 2023-24 volume-6 CDS-3

40

1467

58710

... More
code293 - Supply of LT 2 Pin Cross Arm with clamps bolts nuts for RCC Pole - 9 Mtr Long 145 Kg WL. ESCOM SR 2023-24 volume-6 CDS-3

40

273

10959.2

... More
code294 - Fixing ofLT 2 Pin Cross Arm with clamps bolts nuts for RCC Pole - 9 Mtr Long 145 Kg WL. ESCOM SR 2023-24 volume-6 CDS-3

40

164

6592

... More
code295 - Concreting Material for 9mtrs RCC Poles structure.base concreting cc 1 4 8 500x650x150mm. ESCOM SR 2023-24 volume-6 CDS-28

221

321

71020.56

... More
code296 - pole concreting cc 1 2 4 650x500x1700mm. ESCOM SR 2023-24 volume-6 CDS-28

221

4629

1023196.85

... More
code297 - providing coping for poles with cc 1 2 4 and as per norms. ESCOM SR 2023-24 volume-6 CDS-28

221

321

71020.56

... More
code298 - Supply and Fixing of GI Wire 8 SWG. ESCOM SR 2023-24 volume-6 CDS-24

265.2

77

20497.308

... More
code299 - PART-E 250KVA SUBSTION YARD DETAILS Supply of 11 kV 3 Core XPLE HTUG Cable with pressure extruded inner sheeth ROUND WIRE ARMOURED as per IS-7098 Part-2 Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm 54 GI Wires - 2.5 mm Dia . ESCOM SR 2023-24 PART-2 PAGE-15 ITEAM NO-36.01

0.5

916355

458177.99

... More
code300 - Supply of Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable.3Cx95sqmm indoor. ESCOM SR 2023-24 PART-2 PAGE-20 ITEAM NO-45.01

20

3856

77126.4

... More
code301 - Supply of Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3Cx95sqmm outdoor. ESCOM SR 2023-24 PART-2 PAGE-20 ITEAM NO-45.07

20

4189

83780.2

... More
code302 - Supply of Cable covering tiles 250x125x40mm.. ESCOM SR 2023-24 PART-2 PAGE-32 ITEAM NO-68.06

500

10

5280

... More
code303 - Supply of River sand.BESCOM SR PART-3 PAGE-23 ITEAM NO-66.11 CSR 23-24 VOL I PA-40 SL.NO 64

30

1812

54384

... More
code304 - Supply of RCC humepipes 2000mm long 150mm dia. ESCOM SR 2023-24 PART-2 PAGE-32 ITEAM NO-68.01

20

316

6324.2

... More
code305 - Supply of Collars for RCC hume pipes. ESCOM SR 2023-24 PART-2 PAGE-32 ITEAM NO-68.03

20

84

1689.2

... More
code306 - Supply of GI pipe 150mm dia.BESCOM SR PART-3 PAGE-16 ITEAM NO-48.09 100MM DIA VOL V SlNo 177 P-A30

20

1051

21032.6

... More
code307 - Supply of Route and Joint indicating stones with MS Anchor rod. ESCOM SR 2023-24 PART-2 PAGE-32 ITEAM NO-68.08

50

136

6849.5

... More
code308 - Cable trench excavation 10x0.6x1equal to6 Ordinary soil Extracted from Vol-1 PWD SR Sl No. 1.17.1 . ESCOM SR 2023-24 VOLUME-6 CDS-19

60

269

16191.6

... More
code309 - Laying of cable in Existing TrenchperGI pipeperStone WareperRCC Hume pipe using WoodenperAluminum Rollers as directed by the departmental staff.3x95 to 150 Sqmm ESCOM SR 2023-24 PART-2 PAGE-52 ITEAM NO-21.02

0.5

63161

31580.83

... More
code310 - Retailing the cable trenches with selected availble earth from trench excavation including watering Consolidation in layers of 15Cm thickness including depositing of the surplus earth with a lead of 200Mtrs.BESCOM SR PART-4 PAGE-8 ITEAM NO-29.07

7

59

418.18

... More
code311 - Making and Fixing pot head for HT Cable only.Heat shrinkable Type Terminations.3x95 to 3x150 Sqmm.. ESCOM SR 2023-24 PART-2 PAGE-52 ITEAM NO-22.04

40

2737

109509.6

... More
code312 - Covering the cables with tiles. ESCOM SR 2023-24 PART-2 PAGE-56 ITEAM NO-27.01

0.3

4498

1349.403

... More
code313 - Spreading and forming with sand alround the cable to a depth of 75mm and width of 500mm . ESCOM SR 2023-24 PART-2 PAGE-56 ITEAM NO-28.09

0.3

15254

4576.29

... More
code314 - Laying and Jointing the pipes 100-150 mm Dia including lowering in Position Fixing Collars etc. Joining with mud mortor complete.RCC Pipe.. ESCOM SR 2023-24 PART-2 PAGE-56 ITEAM NO-28.06

20.1

71

1428.507

... More
code315 - Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows bends Tees and other fitting with Cuts and Threads wherever necessary complete.. ESCOM SR 2023-24 PART-2 PAGE-56 ITEAM NO-28.08

60

95

5747.4

... More
code316 - Fixing of Route Joint Indicating Slab.. ESCOM SR 2023-24 PART-2 PAGE-56 ITEAM NO-27.02

90

119

10753.2

... More
code317 - Supply of Load Break switches with Panel ESCOM SR 2023-24 PART-2 PAGE-17 ITEAM NO-41.01

10

75436

754361.7

... More
code318 - Erection Alignment and fixing of Load break switch on the platform.BESCOM SR 2020-21 PART-4 PAGE-4 ITEAM NO-41.02

10

2140

21403.4

... More
code319 - Construction of platform 1.5x1.5x1.2 mtr in size stone cement concrete for erection of Metering cubical Transformer and Load break switch Excavation of 1.5x1.5x1 mt pit for foundation providing and laying cement concrete 1 4 8 for foundation laid in 10cm thick layers well compacted curing etc. complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1 6. Providing cement concrete Slab 1.5x1.5x0.10 Mtr with cement concrete 1 2 4 mix forming and cutting complete providing .ing to stone masonary in cement morter 1 3 after racking joint and nisely lining curing etc. plastering the concrete surfaces in cement morter 1 4 including smooth randering curing etc. curing at every stages completely AS CIVIL AS REFER SUB ESTIMATION

30

22409

672291.3

... More
code320 - supply of Distribution Transformer - 3 Phase 11kVper433V - Stacked CRGO Core with Oil as per IS-1180 Part-1 2014.21. 250 kVA Aluminium Wdg Star 2 5 Star . ESCOM SR 2023-24 PART-2 PAGE-7 ITEAM NO-12.18

10

558976

5589768.8

... More
code321 - Erection of 200 - 250 kVA Transformer. ESCOM SR 2023-24 PART-2 PAGE-46 ITEAM NO-8.03

10

2346

23463.4

... More
code322 - Supply of LT Distribution Box for 250 kVA with MCCB ESCOM SR 2023-24 VOLUME-6 CDS-31

10

23498

234984.2

... More
code323 - Fixing of LT Distribution Box for 250 kVA with MCCB ESCOM SR 2023-24 VOLUME-6 CDS-31

10

395

3955.2

... More
code324 - Supplying fixing wiring earth electrode for grounding conduits I.C.cutouts and other equipment s on the mete rboard using 40mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and char coal150mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc. is to be established through GI wire of size as per lSI specification7.3.3.of IS732 using 12 mm dia bolts nuts washers and check nuts etc. the pipe shall have 16 through holes of 12 mm dia. KPWD ELE SR 2023-24 P.No.54 I.No.12.56

40

3615

144612

... More
code325 - Supplying fixing and wiring earth electrode for grounding of lifts transformers DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.. KPWD ELE SR 2023-24 P.No.54 I.No.12.57

160

4383

701388.8

... More
code326 - Supplying and running of GIperCopper strips for grounding connections using necessary fixing materials as required. GI strip GI Strip. 25x3mm KPWD ELE SR 2023-24 P.No.54 I.No.12.58.1

400

84

33784

... More
code327 - Supplying and running of GIperCopper strips for grounding connections using necessary fixing materials as required. GI strip GI Strip. 50 x 6 mm GI strip KPWD ELE SR 2023-24 P.No.54 I.No.12.58.5

1200

224

269448

... More
code328 - Supplying and running of GIperCopper strips for grounding connections using necessary fixing materials as required. GI strip Copper strip. 25x3mm. KPWD ELE SR 2023-24 P.No.55 I.No.12.58.7

320

587

187872

... More
code329 - Supplying and running of GIperCopper strips for grounding connections using necessary fixing materials as required. 600x600x3mm Copper plate. KPWD ELE SR 2023-24 P.No.55 I.No.12.58.11

20

7643

152872.6

... More
code330 - Providing chain link fencing 50mm size of 8 guage properly stretched between rectangular poles and fixed with suitable bolts and nuts the free ends shall be welded to the pole and block pipe at top and bottom as required including cost of all materials labour lead and lifts cutting bending wherever necessary wastage and lapping etc. complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint.BESCOM SR PART-3 PAGE-12 ITEAM NO-38

750

844

633450

... More
code331 - PART-F ELECTRICAL OUTDOOR PANELS Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodperpanel board using necessary screws bolts nuts necessary phase separators handle and wiring complete. Protection of Overload and Short circuit with thermal MagneticperMicro processor release and Earth Fault as per IS-13947 125 A 25 kA ELE SR 2023-24 P.No.16 I.No.5.15.10

20

10651

213024.6

... More
code332 - Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodperpanel board using necessary screws bolts nuts necessary phase separators handle and wiring complete. Protection of Overload and Short circuit with thermal MagneticperMicro processor release and Earth Fault as per IS-13947. Icu equal to Ics 250Amps 35kA. ELE SR 2023-24 P.No.16 I.No.5.15.15

30

24251

727540.5

... More
code333 - Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodperpanel board using necessary screws bolts nuts necessary phase separators handle and wiring complete. Protection of Overload and Short circuit with thermal MagneticperMicro processor release and Earth Fault as per IS-13947. Icu equal to Ics 400-500 A 50 kA ELE SR 2023-24 P.No.16 I.No.5.15.18

10

42741

427419.1

... More
code334 - Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodperpanel board using necessary screws bolts nuts necessary phase separators handle and wiring complete. Protection of Overload and Short circuit with thermal MagneticperMicro processor release and Earth Fault as per IS-13947. Icu equal to Ics Supplying and fixing of Shunt trip suitable for MCCB.CBCT P.No.16 I.No.5.16

10

1754

17540.9

... More
code335 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ONperOFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps SP. ELE SR 2023-24 P.No.16 I.No.5.18.1

240

427

102588

... More
code336 - Supplying fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based digital readout of percentage leakage current programmable delayperautoper manual reset facility suitable to mount on DIN railper flush mounting on panel board. ELE SR 2023-24 P.No.17 I.No.5.21

10

9532

95326.5

... More
code337 - Supplying of multi function digital meter with three line back light LCD type display for voltage Current frequency Power power factor KVA KWH KVAR suitable for 3 phase 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ELE SR 2023-24 P.No.18 I.No.5.33

10

9594

95944.5

... More
code338 - Supplying fixing and wiring 50per5 to 400per5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. ELE SR 2023-24 P.No.18 I.No.5.34

30

578

17365.8

... More
code339 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12per24v D.C. ELE SR 2023-24 P.No.18 I.No.5.38

240

530

127308

... More
code340 - Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve mounted on phenolic per FRP per DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts nuts and washers etc. complete. 400 A 4x50x10 mm Aluminium Strips ELE SR 2023-24 P.No.19 I.No.5.40.3

80

4578

366268

... More
code341 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron and M.S. flat with bolts washers etc. and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6mm ELE SR 2023-24 P.No.19 I.No.5.41.1

60

314

18849

... More
code342 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron and M.S. flat with bolts washers etc. and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm ELE SR 2023-24 P.No.19 I.No.5.41.2

60

406

24411

... More
code343 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts washers etc. and painted with 2 coats of red oxide and then two coats of approved paint. 50X100X50X6mm C channel ELE SR 2023-24 P.No.19 I.No.5.41.4

60

778

46720.8

... More
code344 - Fabricating supplying and mounting MS box made out SWG suitable for floor per wall mounting fully weather proof with provision for better heat dissipation provided with hinged front cover equipped with tamper proof locking arrangements with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc. complete. 14SWG ELE SR 2023-24 P.No.19 I.No.5.42.1

2250000

-

1170000

... More
code345 - Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodperpanel board using necessary screws bolts nuts necessary phase separators handle and wiring complete. Protection of Overload and Short circuit with thermal MagneticperMicro processor release and Earth Fault as per IS-13947. Icu equal to Ics 100 A 25 kA ELE SR 2023-24 P.No.16 I.No.5.15.9

26

8741

227281.86

... More
code346 - Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodperpanel board using necessary screws bolts nuts necessary phase separators handle and wiring complete. Protection of Overload and Short circuit with thermal MagneticperMicro processor release and Earth Fault as per IS-13947. Icu equal to Ics 250Amps 35kA. ELE SR 2023-24 P.No.16 I.No.5.15.15

13

24251

315267.55

... More
code347 - Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodperpanel board using necessary screws bolts nuts necessary phase separators handle and wiring complete. Protection of Overload and Short circuit with thermal MagneticperMicro processor release and Earth Fault as per IS-13947. Icu equal to Ics Supplying and fixing of Shunt trip suitable for MCCB.CBCT P.No.16 I.No.5.16

13

1754

22803.17

... More
code348 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ONperOFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps SP. ELE SR 2023-24 P.No.16 I.No.5.18.1

195

427

83352.75

... More
code349 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ONperOFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN. ELE SR 2023-24 P.No.16 I.No.5.18.9

104

3180

330786.56

... More
code350 - Supplying fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based digital readout of percentage leakage current programmable delayperautoper manual reset facility suitable to mount on DIN railper flush mounting on panel board. ELE SR 2023-24 P.No.17 I.No.5.21

13

9532

123924.45

... More
code351 - Supplying of multi function digital meter with three line back light LCD type display for voltage Current frequency Power power factor KVA KWH KVAR suitable for 3 phase 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ELE SR 2023-24 P.No.18 I.No.5.33

13

9594

124727.85

... More
code352 - Supplying fixing and wiring 50per5 to 400per5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. ELE SR 2023-24 P.No.18 I.No.5.34

39

578

22575.54

... More
code353 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12per24v D.C. ELE SR 2023-24 P.No.18 I.No.5.38

156

530

82750.2

... More
code354 - Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve mounted on phenolic per FRP per DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts nuts and washers etc. complete. 250 A 4 x 30 x 10 mm Aluminium Strips ELE SR 2023-24 P.No.19 I.No.5.40.2

78

3538

275967.9

... More
code355 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron and M.S. flat … with bolts washers etc. and painted with 2 coats of red oxide and then two coats of approved paint. 40*40*6mm ELE SR 2023-24 P.No.19 I.No.5.41.1

52

314

16335.8

... More
code356 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron and M.S. flat … with bolts washers etc. and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm ELE SR 2023-24 P.No.19 I.No.5.41.2

52

406

21156.2

... More
code357 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron and M.S. flat … with bolts washers etc. and painted with 2 coats of red oxide and then two coats of approved paint. 50X100X50X6mm C channel ELE SR 2023-24 P.No.19 I.No.5.41.4

52

778

40491.36

... More
code358 - Fabricating supplying and mounting MS box made out … SWG suitable for floor per wall mounting fully weather proof with provision for better heat dissipation provided with hinged front cover equipped with tamper proof locking arrangements with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc. complete. 14SWG ELE SR 2023-24 P.No.19 I.No.5.42.1

845000

-

439400

... More
code359 - PART-G LT UG CABLE 1.1 kV XLPE or Heat resistant PVC insulated PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1 Armouring strip thickness and resistivity as per IS-3975. 240 Sqmm 3.5 Core 30 GI Strips - 4 x 0.8 mm ESCOMs SR 2023-24 PART-2 P.NO-13 It no-.32.18

3.2

888545

2843347.136

... More
code360 - Laying of cable in Existing TrenchperGI pipeperStone WareperRCC Hume pipe using WoodenperAluminum Rollers as directed by the departmental staff.120 to 240 Sqmm ESCOM SR 2023-24 PART-2 P.NO-52 It no-.21.07

3.2

33246

106388.288

... More
code361 - 1.1 kV XLPE or Heat resistant PVC insulated PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1 Armouring strip thickness and resistivity as per IS-3975. 35 Sqmm 4 Core 15 GI Strips - 4 x 0.8 mm ESCOMs SR 2023-24 PART-2 P.NO-13 It no-.32.10

0.1

181352

18135.21

... More
code362 - Laying of cable in Existing TrenchperGI pipeperStone WareperRCC Hume pipe using WoodenperAluminum Rollers as directed by the departmental staff.35 to 95 Sqmm ESCOM SR 2023-24 PART-2 P.NO-52 It no-.21.06

0.1

32073

3207.317

... More
code363 - Brass Cable Gland 25mm. ESCOM SR 2023-24 PART-2 P.NO-28 It no-.63.01

210

81

17087.7

... More
code364 - Brass Cable Gland 32 mm. ESCOM SR 2023-24 PART-2 P.NO-28 It no-.63.02

20

97

1957

... More
code365 - Brass Cable Gland 40 mm. ESCOM SR 2023-24 PART-2 P.NO-28 It no-.63.03

20

152

3048.8

... More
code366 - Brass Cable Gland 45 mm. ESCOM SR 2023-24 PART-2 P.NO-28 It no-.63.03

80

202

16232.8

... More
code367 - Supply and making of Aluminium End Terminal Lug 240 Sqmm. ESCOM SR 2023-24 It no-.60.12

400

62

25132

... More
code368 - PART-H STREET LIGHTING WORKS Supply of 1.1 kV LT Aerial Bunched Cable XLPE insulation confirming to IS-14255 1995 2x16 Plus 1x25 Sqmm Insulated Messenger cum Neutral.ESCOM SR 2023-24 PART-2 P.NO-18 It no-42.08

2.2

87775

193106.254

... More
code369 - Stringing of 1.1 kV grade Aerial Bunched 3 Core cable of XLPE insulation of size 3x95 Phase Conductor plus 1x70 Insulated Messenger Neutral plus 1x16 Street Light Control . ESCOM SR 2023-24 PART-2 It no-24.03

2.2

34102

75024.994

... More
code370 - Supply of Piercing connector suitable for 16 Sqmm - 95 Sqmm AB Cable - Street Light Connections. PART-5 CDS-37 It no-6 . ESCOM SR 2023-24 PART-2 P.NO-18 It no-43.12

65

191

12452.7

... More
code371 - Installation of Insulation piercing connector for Main to Street Light Main 16-95 Sqmm Tap 1.5-10 Sqmm EP95 ESCOM SR 2023-24 PART-2 It no-24.12

65

92

6025.5

... More
code372 - Suspension Clamp Assembly 16 to 70 Sqmm Bare Messenger Exclusive of Pole Clamp and Eye Hook . ESCOM SR 2023-24 PART-2 P.NO-18 It no-43.19

65

227

14795.95

... More
code373 - Erection of Anchor Clamp -25 to 95 Sqmm bareperInsulated messenger. ESCOM SR 2023-24 PART-2 P.NO-54 It no-24.07

65

148

9640.8

... More
code374 - Supply of Pre - Insulated Lug - CPTAU for 16 Sqmm. ESCOM SR 2023-24 PART-2 P.NO-19 It no-43.26

130

146

19013.8

... More
code375 - Installation of Pre-Insulated Lug - CPTAU for 16 Sqmm. ESCOM SR 2023-24 PART-2 P.NO-54 It no-24.21

130

164

21424

... More
code376 - Straight Joint Suitable for 16 Sqmm LT ABC - MJPT Type. ESCOM SR 2023-24 PART-2 P.NO-19 It no-43.32

10

254

2544.1

... More
code377 - Installation of Pre-insulated straight thru joints-MJPT for 16 Sqmm cable. ESCOM SR 2023-24 PART-2 P.NO-54 It no-24.16

10

263

2636.8

... More
code378 - Supply of PVC Wire - 2.5 Sqmm Weight per 100 Mtr Coil 1.8 Kg ESCOM SR 2023-24 PART-2 P.NO-21 It no-48.01

5

1528

7642.6

... More
code379 - Laying of cable in Existing TrenchperGI pipeperStone WareperRCC Hume pipe using WoodenperAluminum Rollers as directed by the departmental staff.2.5 to 25 Sqmm ESCOM SR 2023-24 PART-2 P.NO-52 It no-.21.05

0.5

21512

10756.29

... More
code380 - Supply of Dead End ClampperAnchor Clamp Assembly 16 to 70 Sqmm Bare Messenger Exclusive of Pole Clamp and Eye Hook . ESCOM SR 2023-24 PART-2 P.NO-19 It no-43.17

4

238

955.84

... More
code381 - Open Conduit System Supplying heavy gauge PVC conduit pipe dia .mm thick confirming to IS 2509 with suitable size bends junction boxes adhesive paste etc. and fixing using inverted wood plugs in case of RCC ceiling and RCC wall per stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.40 mm dia 2.5 mm thick KPWD ELE SR 2023-24 PART-3 P.N0.2 I.No. 1.1.4

50

153

7673.5

... More
code382 - Supplying and fixing of 4 pole power contactor with NOperNC contacts on existing woodperpanel boaard using necessary bolts nuts washers and wiring etc. completee with ac-3 rating and as per IS-13947 40 Amps. KPWD ELE SR 2023-24 P.No.16 I.No.5.14.3

2

6302

12605.14

... More
code383 - Supply and Installation per Fixing per Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid shock proof IP65 Weather Proof rust proof dust proof water proof corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase per Three Phase Energy Meter in suitable base plate and having a provision for Fuse per MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mm x600mmx170mm KPWD ELE SR 2023-24 P.No.21 I.No.5.44.4

2

14955

29911.2

... More
code384 - Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts nuts and washers. KPWD ELE SR 2023-24 P.No.21 I.No.5.48

2

4988

9976.58

... More
code385 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K IP 66 optical and electrical compartment and impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains Surge Protection- Min 5KV along with Over voltageper Overload short circuitper miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50per60Hz application. Compliance to IS 10322perIEC 60598 LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencygreater than130lmperw nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABLperCPRI and any Government certified agency and Design and Development facility certified by ISO 9001 2008 . Housing with supplier word mark pername shall be Engraved per Embossing on the die cast housingper Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeperNichiaper LumiledsperOsram make LED Source. LED Streetlight 90 W KPWD ELE SR 2023-24 P.No.46 I.No 11.8.4

65

9125

593177

... More
code386 - Fixing halogenpermetal halide per SVL per IL per LED floodlight fitting over existing pole per wall ceiling including clamps bolts nuts and wiring using suitable capacity wires KPWD ELE SR 2023-24 P.NO.56 I No 13.5

73

166

12180.78

... More
code387 - Supply of LT 2 Pin Cross Arm with clamps bolts nuts for RCC Pole - 9 Mtr Long 145 Kg WL. ESCOM SR 2023-24 volume-6 CDS-3

73

273

20000.54

... More
code388 - Fixing ofLT 2 Pin Cross Arm with clamps bolts nuts for RCC Pole - 9 Mtr Long 145 Kg WL. ESCOM SR 2023-24 volume-6 CDS-3

73

164

12030.4

... More
code389 - Supplying and Fixingmm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MVperSVperMHperFTL street light fitting of all capacities on railperRCCperwallpertubular pole using suitable clamps bolts nuts and wiring using suitable capacity wires.Using 32mm dia G.I.Pipe KPWD ELE SR 2023-24 P.No.55 I.No.13.2.2 .

73

1333

97371.05

... More
code390 - Fabrication Supplying Erection Testing and Commissioning of ms long Polygon high mast with SingleperMultiple telescopic sections having minimum overlap distance of 1.5 times of top section thickness as per BSEN 10025 grades 355 JOperASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 mpers as per IS 875 part 3 as per GA Drawing . Base plate as per IS 2062perASTM A572-50. The mast shall be Galvanized in single Hot-dip as per BSEN ISO 1461perASTM A123 with an average 70 microns as per IS 2629 and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys stainless steel axle Phosphorus Bronze bearing bush press- fitted with separate guides for 2 runs of 5 mm dia stainless steel wire rope of AISI 304grade 7per19-core Factor of Safety as per TR no-7 . 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manualperpower tool Suitable reversible geared motor operating on 230per415V 50Hz shall be provide above 15 Mtr mast The mast shall have lantern of 2 segments suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. excluding foundation as per technical data.12 mper12.5 m - Top 100 mm and Bottom 310 mm dia KPWD ELE SR 2023-24 P.No.12 I.No.4.5.1 .

2

134930

269860

... More
code391 - Supplying and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts nuts etc. complete.Single Arm Bracket with 1500 mm Standard 40per50 mm dia KPWD ELE SR 2023-24 P.No.12 I.No.4.6.2 .

2

2163

4326

... More
code392 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonateperclear glass material delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage CCT greater than 5500K IP 66 optical and electrical compartment and impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains Surge Protection- Min 5KV along with Over voltageper Overload short circuitper miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50per60Hz application. Compliance to IS 10322per IEC 60598 LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with . W System Power consumption. LED Efficiencygreater than 1301mperw nominal CRI greater than75. Luminaire manufacturer should have in- house facility accredited by NABL per CPRI and any Government certified agency and Design and Development facility certified by ISO 9001 2008. Housing with supplier word mark per name shall be Engraved per Embossing on the die cast housing per Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeperNichiaper LumiledsperOsram make LED Source.LED Floodlight 150W KPWD ELE SR 2023-24 P.No.45 I.No.11.9.4 .

8

12864

102917.6

... More
code393 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and Virgin PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694 1990.3C x 2.5 mm2 KPWD ELE SR 2023-24 P.No.5 I.No.2.5.8 .

120

116

13966.8

... More
code394 - Wiring for lightingperpower circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 2010. 4 mm2 KPWD ELE SR 2023-24 P.No.4 I.No.2.3.4 .

120

64

7786.8

... More
code395 - PART-I KPTCL SIDE WORKS AS PER KPTCL ESCOMS SR 2023-24 VOLUME-6 Supply of 11 kV MCVCB500 MVA25 kA1600 A incomer 1250 A feeder SCADA-DAS compatible.Feeder Panel.KPTCL SR 2023-24 PG NO.28 IT NO.4.7

1

1037998

1037998.5

... More
code396 - Supply of Adapter Panel for MCVCB Adapter Panel 3000 A.KPTCL SR 2023-24 PG NO.29 IT NO.4.10.

1

246477

246477

... More
code397 - Supply of Annunciator Panel for the following combinations for both MCVCB and PCVCB.Annunciator Panel for Single Feeder.KPTCL SR 2023-24 PG NO.30 IT NO.4.11.

1

54631

54631.5

... More
code398 - COPPER CONTROL CABLE :Supply of 19C x 2.5 Sq mm.KPTCL SR 2023-24 PG NO.40 IT NO.13.16.

150

551

82687.5

... More
code399 - COPPER CONTROL CABLE :Supply of 4C x 2.5 Sq mm.KPTCL SR 2023-24 PG NO.40 IT NO.13.6.

150

149

22365

... More
code400 - COPPER CONTROL CABLE :Supply of 2C x 2.5 Sq mm.KPTCL SR 2023-24 PG NO.40 IT NO.13.1.

150

98

14805

... More
code401 - COPPER CONTROL CABLE Supply of 4C x 6 Sq mm.KPTCL SR 2023-24 PG NO.40 IT NO.13.8.

150

259

38902.5

... More
code402 - Supplying and installation of RUBBER MAT 1mtr x 1mtr -1Omm thick. complete including cost of materialslabourusage charges of machinery complete as per specifications.PWD ELE SR 23-24 PG NO-34 15.117

2

2089

4179

... More
code403 - Supply of 8 Channel 220per110 V Opto Coupler.KPTCL SR 2023-24 PG NO.48 IT NO.24.5.1

1

1377

1377.6

... More
code404 - Supply of Multi Function Transducer MFT.KPTCL SR 2023-24 PG NO.48 IT NO.24.5.2

1

5118

5118.75

... More
code405 - Supplying and drawing PVC insulated flexible copper wire of approved make as per IS 694 2010.14per0.0052.PWD ELE SR 23-24 PG NO-5 It no-2.4.4.

104

23

2402.4

... More
code406 - Copper Control per Communication Cable for SCADA.Supply of Signal cable Armoured Copper 10C x 0.5 Sq mm multistrand.KPTCL SR 2023-24 PG NO.48 IT NO.24.4.1

100

150

15015

... More
code407 - Copper Control per Communication Cable for SCADA.Supply of 10C x 1.5 Sq mm multi strand conforming to KPTCL specification.KPTCL SR 2023-24 PG NO.48 IT NO.24.4.2

100

162

16275

... More
code408 - 11 kV Switchgear-Erectionalignment and fixing to the foundationindoorperoutdoor 11 kV switchgear panelperunit including movement from the point of unloading to the point of erection.11 kV Indoor per Outdoor Switchgear.KPTCL SR 2023-24 PG NO.121 IT NO.24ai

1

2185

2185.05

... More
code409 - Laying of control cables from equipment to control panels Laying of 19C x 2.5 Sq mm.KPTCL SR 2023-24 PG NO.120 IT NO.22b.

150

15

2362.5

... More
code410 - Laying of control cables from equipment to control panels Layingof 4C x 2.5 Sq mm.KPTCL SR 2023-24 PG NO.120 IT NO.22b.

150

15

2362.5

... More
code411 - Laying of control cables from equipment to control panels Layingof 2C x 2.5 Sq mm.KPTCL SR 2023-24 PG NO.120 IT NO.22b.

150

15

2362.5

... More
code412 - Laying of control cables from equipment to control panels Layingof 4C x 6 Sq mm.KPTCL SR 2023-24 PG NO.120 IT NO.22b.

150

15

2362.5

... More
code413 - Making and Fixing pot head for HT Cable only.3x300 to 3x400 Sqmm.EC-SR 23-24L

1

2790

2790.9

... More
code414 - Grounding of equipment by providing cast iron pipe of 100 mm ID 13 mm thickness 2.75 metre long with 2 part clamp out of G.I.Flat 50 x 6 mm continuously welded alround the pipe using cast iron welding electrodes as per drawing including the cost of excavation All materials to be supplied by the contractor12 792 plus 3 491equal16283.KPTCL SR 2023-24 PG NO.115 IT NO 6C.

1

17097

17097.15

... More
code415 - Grounding of equipment with 50x6 mm G.I. Flat and connecting equipment to the earth mat per ground pit. Each point of earthing with all formation works like bending twisting drilling of holes and connecting by welding inclusive of all TandP and consumables to the earth mat per ground pitperpoint of earth connectionall the materials supplied by the contractor.KPTCL SR 2023-24 PG NO.123 IT NO 6f.

60

351

21105

... More
code416 - Laying and termination of DIperDOperCommunication Cables.KPTCL SR 2023-24 PG NO.128 IT NO 29Ha.

250

26

6562.5

... More
code417 - Fixing and wiring of Opto Coupler.KPTCL SR 2023-24 PG NO.128 IT NO 29Hb.

1

1632

1632.75

... More
code418 - Fixing and wiring of MFT.KPTCL SR 2023-24 PG NO.128 IT NO 29Hc.

1

1632

1632.75

... More
code419 - Configuration of RTU and Engineering along with validation of data at SLDC.KPTCL SR 2023-24 PG NO.128 IT NO 29Hd.

1

2500

2500.05

... More
code420 - Wiring and Assisting in Testing and Commissioning.11 kV Indoor per Outdoor Switchgear.KPTCL SR 2023-24 PG NO.122 IT NO 24bi.

3

988

2964.15

... More
code421 - Supply of 11kV3x240 Sqmm XLPE UG Cable.ESCOM SR 2023-24 volume-6 CDS-21

0.51

1705729

869922.0144

... More
code422 - Testing and Commissioning Wiring Identification of wiresferrulingcrimping and termination of wires for annunciationetc.Testing of relaysCTsPTs and Breaker for operation.For single 11 kV panel outdoor typeperkiosk.KPTCL SR 2023-24 PG NO.122 IT NO 24ci.

1

19922

19922.7

... More
code423 - Providing Electrical arrangements for Pump.house

1

71506

71506



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.