Karnataka State Small Industries Development Corporation Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka State Small Industries Development Corporation - KSSIDC Tender

Works
Civil And Construction
Building Construction
Opening Date3 Jan 2025
Closing Date18 Jan 2025
Tender Amount₹ 95,73,053.86 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
CODE4 - Demolishing brick work manually by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar.

20

1131

22638

... More
CODE5 - Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge.

1994

40

81155.8

... More
CODE6 - Demolishing cement concrete manually by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge.

38

1829

69513.4

... More
CODE7 - Cost of Haulage Excluding Loading and Unloading, Taking output 10 t load and lead 10 km equal 100 t.km

5100

13

67320

... More
CODE8 - Taking out doors, windows and clerestory window shutters steel orwood including stacking to the appropriate disposal area as per direction of Engineer-in-charge.

229

103

23678.6

... More
CODE9 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

2.4

11785

28285.176

... More
CODE10 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications.Mix 1-2-4 Using 20 mm nominal size graded crushed coarse aggregates.

8

6935

55487.76

... More
CODE11 - Supplying Fitting and Placing un-coated TMT bar Reinforcement in sub-structure complete as per Drawing and Technical Specifications. Buildings

0.24

98402

23616.648

... More
CODE12 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg-m3 and minimum compressive strength of 4.00 N-mm2 conforming to IS 2185 -Part - I - 2005 and constructed with CM 1-4 as per IS 2572-2005 including cost of all materials labour scaffolding and curing usage charges of machinery etc complete as per specifications.

96

1226

117747.84

... More
CODE13 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg-m3 and minimum compressive strength of 4.00 N-mm2 conforming to IS 2185 -Part - I- - 2005 and constructed with CM 1-4 as per IS 2572-2005 including cost of all materials labour scaffolding and curing usage charges of machinery etc complete as per specifications.

97.8

1455

142339.098

... More
CODE14 - Polyurethane based Single Component for Existing Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace-Chajjas-Sunken portion of WC-Bathroom cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percentage and tensile strength greater than 2MPa as per ASTM D412 The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT -dry film thickness- of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation making coving at Junction Bore Packing treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge.

688

810

557761.6

... More
CODE15 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix- 1-4 -1 cement- 4 fine sand- to brick masonry including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineer-in-charge.

2254

387

873965.96

... More
CODE16 - Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 percentage and conforming to I.S. 15622 of approved make in all colours and shade over 12 mm thick bed of cement mortar 1-3 -1 cement- 3 coarse sand- jointing with grey cement slurry at 3.3 kg- m2 including grouting the joint with white cement and matching pigments etc. complete.Size of Tile 600x600 mm

524

1305

684045.32

... More
CODE17 - Providing and laying Polished Granite stone flooring in required design and patterns in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm -average- thick base of cement mortar 1-4 -1 cement - 4 coarse sand- laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab Black Cherry Red Brown Cat Eye River Pink or equivalent.

167

3168

529151.19

... More
CODE18 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm -thickness to be specified by the manufacturer- of 1st quality conforming to IS - 15622 of approved make in colours such as White Ivory Grey Fume Red Brown laid on 20 mm thick cement mortar 1-4 -1 Cement - 4 Coarse sand- Jointing with grey cement slurry at 3.3 kg-m2 including pointing the joints with white cement and matching pigment etc. complete.

40

1195

47817.6

... More
CODE19 - Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS - 15622 -thickness to be specified by the manufacturer - of approved make in all colours shades except burgundy bottle green black of any size as approved by Engineer-in-Charge in skirting risers of steps and dados over 12 mm thick bed of cement Mortar 1-3 -1 cement- 3 coarse sand- and jointing with grey cement slurry at 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete.

86

1228

105674.22

... More
CODE20 - Providing Red Salwood frames of doors windows clerestory windows ventilators and other frames wrought framed or assembled including making plaster groves -excluding cost of cement concrete and side clamps- but including cost of materials labour usage charges complete as per specifications.

0.4

109566

43826.4

... More
CODE21 - Providing and fixing factory made single extruded WPC -Wood Polymer Composite- solid door-window-Clerestory windows and other Frames- Chowkhat comprising of virgin PVC polymer of K value 58-60 -Suspension Grade- calcium carbonate and natural fibres -wood powder-rice husk- wheat husk- and non toxic additives -maximum toxicity index of 12 for 100 g- fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg-m3 screw withdrawal strength of 2200 N -Face- and 1100 N -Edge- minimum compressive strength of 58 N-mm2 modulus of elasticity 900 N-mm2 and resistance to spread of flame of Class A category with property of being termite-borer proof water-moisture proof and fire retardant and fixed in position with M.S hold fast-lugs-SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. -Fixtures shall be paid for separately- Size 62 x 100mm

52

772

40154.4

... More
CODE22 - Providing and fixing flush door shutter made out of solid core block board type well seasoned chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets -core veneer- hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 -part-I- 1991. from manufacturer complete as per spcification. 30 mm thick Both side teak

45

4447

200128.5

... More
CODE23 - Providing and fixing factory made Green certified Anti Termite UV resistant high water absorbant single extruded WPC -Wood PolymerComposite- solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 -Suspension Grade- calcium carbonate and natural fibers -wood powder-rice husk-wheat husk- and non toxic additives -maximum toxicity index of 12 for 100 g- having minimum density of 650 kg-m3 and screw withdrawal strength of 1800 N -Face- and 900 N -Edge- minimum compressive strength of 50 N-mm2 modulus of elasticity 850 N-mm2 and resistance to spread of flame of Class A category with property of being termite-borer proof water-moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials transportation labour and fixing charges.-Cost of Fixtures to be paid separately- 30 mm thickness

22

3833

84337

... More
CODE24 - Providing and fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC-Matching to RAL-9016- sections and with minimum TiO2-Titanium Dioxide-at 6PHR with TPE-Thermo Plastic Elastomer- and lead free gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm.Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm.Windows shall be provided with 6mm plain float glass standard hardwareand Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm-2.5mm.Maximum possible size 2419mm x 2200mm. -The cost is inclusive of all fixtures and separate charges for minor TandPs shall not be made

149

7407

1103702.6

... More
CODE25 - Providing and fixing of louvered ventilator made out of multi chambered UPVC-Matching to RAL-9016- sections and with minimum TiO2-Titanium Dioxide- at 6PHR with TPE-Thermo Plastic Elastomer- and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium -powder coated in white- will be used on the frame along with plastic parts for fixing the 4 mm pin head glassWall thickness of frame shall be 2mm Maximum possible size size1000mm x 1000mmThe cost is inclusive of all fixtures and separate charges for minor TandPs shall not be madeThe cost is inclusive of all fixtures and separate charges for minor TandPs shall not be made

10

6290

62909

... More
CODE26 - Providing fabricating and fixing of 6 mm thick High Pressure Laminate sheets in standard size of 1200 mm multiple 2400 mm -Sheets can be supplied in customized length depending on requirement- Sheets shall be manufac tured involving a series of mechanical process in a state-of-the-art facility shall comprise of 0.25 mm Aluminium skins on both sides sandwiching an LDPE -Low Density Poly Ethylene- core having a density of 0.92 g-cm3 giving the overall weight of HPL at 7.8 kg-m2 Aluminium skins to have a desired lacquer in Lumiflon coated on one side-Both side The supplied panels shall have a dexterity to be formed in convex and concave shapes as also the ability to bend in 90 degrees under a mechanical process. Panel will be installed on Aluminium tubes at 500 mm c-c distance with special L brackets There will be special fixing treatment on all the corner sections. Aluminium tube size will be 25 mm multiple 50 mm Boards will be fixed on the Aluminium channels with colour matched rivets- MS polymer Adhesives and brackets through 8 mm drill hole in boards and 5 mm dia drill holes in aluminium box Rivets will be installed by automatic rivet guns - adhe sive should be used with proper silicone extrusion gun and properly laid over panel and aluminium tube on every 500mm gap as per direction of Engineer in charge Solid-Dark textured Colored sheets-Double sided

203

3791

769715.1

... More
CODE27 - Providing and fixing glazing in aluminium door window ventilator shutters and partitions etc with EPDM rubber -neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge -Cost of aluminium snap beading shall be paid in basic item-With float glass panes of 4.0 mm thickness -weight not less than 10kg- m² including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge

16

1086

17388.8

... More
CODE28 - Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections power pressed from M S sheets and galvanized with zinc coating of 120 g-m2 both side inclusive as per IS - 277 and consisting of angle cleats of size 25 mm wide multiple 1.6 mm thick with flanges of 27 mm and 37mm at 1200 mm centre to centre one flange fixed to the ceiling with dash fastener 12.5 mm dia multiple 50mm long with 6mm dia bolts other flange of cleat fixed to the angle hangers of 25 multiple 10 multiple 0.50 mm of required length with nuts at bolts of required size and other end of angle hanger fixed with intermediate G I channels 45 multiple 15 multiple 0.9 mm running at the spacing of 1200 mm centre to centre to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm at 450 mm centre to centre shall be fixed in a direction perpendicular to G I intermediate channel with connecting clips made out of 2.64 mm dia multiple 230 mm long G I wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall-partition with the help of rawl plugs at 450 mm centre with 25mm long dry wall screws at 230 mm interval including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 multiple 25 mm at 230 mm c-c including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound jointing tapes finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufactures specification and also including the cost of making openings for light fittings grills diffusers cutouts made with frame of perimeter channels suitably fixed all complete as per drawings specification and direction of the engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge Glass Reinforced Gypsum GRG board conforming to IS- 2095- Part - 1996 Board with BIS Certification marks only

143

1208

172872.7

... More
CODE29 - Providing and fixing tiled false ceiling of specified materials of size 595 multiple 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections -galvanized at120 g-m2 both side inclusive- consisting of main T runner with suitably spaced joints to get required length and of size 24 multiple 38 mm made from 0.30 mm thick -minimum- sheet spaced at 1200 mm center to center and cross T of size 24 multiple 25 mm made of 0.30 mm thick -minimum- sheet 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200 multiple 600 mm and secondary cross T of length 600 mm and size 24 multiple 25 mm made of 0.30 mm thick -minimum- sheet to be interlocked at middle of the 1200 multiple 600 mm panel to form grids of 600 multiple 600 mm and wall angle of size 24 multiple 24 multiple 0.3 mm and laying false ceiling tiles of approved texture in the grid including required cutting/making opening for services like diffusers grills light fitting fixture smoke detectors etc Main Trunners to be suspended from ceiling using GI slotted cleats of size 27 multiple 37 multiple25 multiple1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 multiple 30 multiple 0.8 mm spaced at 1200 mm center to center along main T bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint all complete for all heights as per specifications drawings and as directed by Engineer-in-charge12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595 multiple 595 mm madeof Gypsum plasterboard manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit

49

2175

106614.2

... More
CODE30 - Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge

2254

110

247940

... More
CODE31 - Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface -Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer-in-charge

2254

58

131408.2

... More
CODE32 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications- Two coats applied on walls at 1.25 L-10 m² over and including one coat of Special primer applied at 0.75 L-10 m² with paint of approved quality to give an even shade after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer-in-charge The gloss should be 50 percentage at 60 degree angle with 10 years life

2254

173

391745.2

... More
CODE33 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade -Two coats on new work after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer-in-charge

197

126

24920.5

... More
CODE34 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Handles 300mm

15

605

9075

... More
CODE35 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia 300mm

15

412

6187.5

... More
CODE36 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Tower Bolts 150 multiple 10mm

20

132

2640

... More
CODE37 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Tower Bolts 200 multiple 10mm

20

165

3300

... More
CODE38 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS hinges 125 mm

40

55

2200

... More
CODE39 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Door stopper 75mm

20

110

2200

... More
CODE40 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Handles 200mm

24

495

11880

... More
CODE41 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia 200mm

15

330

4950

... More
CODE42 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Tower Bolts 150 multiple 10mm

17

132

2244

... More
CODE43 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Tower Bolts 200 multiple 10mm

17

165

2805

... More
CODE44 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS hinges 125 mm

51

55

2805

... More
CODE45 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Door stopper 75mm

10

110

1100

... More
CODE46 - Providing and fixing aluminium die cast body tubular type universal hydraulic door closer having brand logo with ISI IS - 3564 embossed on the body door weight upto 35 kg and door width upto 700 mm- with necessary accessories and screws etc complete

20

1225

24508

... More
CODE47 - Providing and fixing chromium p12.6 lated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc complete

20

1157

23144

... More
CODE48 - Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc complete

7

1089

7623

... More
CODE49 - Providing and fixing Roller Blinds of reputed make 38mm round Aluminium channel with blackout fabric telting with chain -Ball- system with all necessary fittings and fixtures as per direction of Engineer in charge

144

1944

279936

... More
CODE50 - Providing and fixing Chorinated Poly Venyl Chloride -CPVC- pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per the direction of Engineer Incharge exposed on wall- 50mm nominal OD pipes

30

859

25773

... More
CODE51 - Providing and fixing Chorinated Poly Venyl Chloride-CPVC- pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete internal work exposed on wall - 20mm nominal OD pipes

155

266

41261

... More
CODE52 - Supplying PVC ringtite pipes conforming to IS 4985-2000 with latest amendments and conveying to worksite rolling and lowering into trenches laying true to line and level and perfect linking at joints testing and commissioning including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials -excluding cost of specials- with jointing of approved type with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excavation etc complete and giving necessary hydraulic test to the required pressure as per ISS -Contractor will make his own arrangements for procuring water for testing-etc for- PVC pipes 110mm dia 6 kg-sqcm and class 3

85

452

38428.5

... More
CODE53 - Supplying PVC ringtite pipes conforming to IS 4985-2000 with latest amendments and conveying to worksite rolling and lowering into trenches laying true to line and level and perfect linking at joints testing and commissioning including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials -excluding cost of specials- with jointing of approved type with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excavation etc complete and giving necessary hydraulic test to the required pressure as per ISS -Contractor will make his own arrangements for procuring water for testing- etc for- PVC pipes 75mm dia 6 kg-sqcm and class 3

30

242

7260

... More
CODE54 - Supplying of special moulded variety PVC couplers as per IS 7834- 1987 and fabricated as per IG124- 1984 with ISI mark and with its latest amendments to walk site et complete 75mm dia PVC couplers

10

73

737

... More
CODE55 - Supplying of special moulded variety PVC couplers as per IS 7834- 1987 and fabricated as per IG124- 1984 with ISI mark and with its latest amendments to walk site etc complete 110mm dia PVC couplers

10

188

1881

... More
CODE56 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834- 1987 and fabricated as per IG124- 198-4 with ISI mark with its latest amendments 75 mm dia PVC Elbows

10

211

2112

... More
CODE57 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834- 1987 and fabricated as per IG124- 1984 with ISI mark with its latest amendments 110 mm dia PVC Elbows

10

332

3322

... More
CODE58 - Supply and delivery at site special moulded variety PVC tee as per IS 7834- 1987 and fabricated as per IG124- 1984 with ISI mark with its latest amendments 75 mm dia PVC Tee

10

128

1287

... More
CODE59 - Supply and delivery at site special moulded variety PVC tee as per IS 7834- 1987 and fabricated as per IG124- 1984 with ISI mark with its latest amendments 110 mm dia PVC Tee

10

276

2761

... More
CODE60 - Supply and delivery at site special moulded variety PVC bend as per IS 7834 - 1987 and fabricated as per IG124- 1984 with ISI mark with its latest amendments 75 mm dia PVC Bend

10

269

2695

... More
CODE61 - Supply and delivery at site special moulded variety PVC bend as per IS 7834 - 1987 and fabricated as per IG124 - 1984 with ISI mark with its latest amendments 110 mm dia PVC Bend

10

541

5412

... More
CODE62 - Supply and delivery at site special moulded variety PVC reducer as per IS 7834 - 1987 and fabricated as per IG124 -198 - 4 with ISI mark with its latest amendments 75 mm dia PVC REDUCER

10

114

1144

... More
CODE63 - Supply and delivery at site special moulded variety PVC reducer as per IS 7834 - 1987 and fabricated as per IG124 - 1984 with ISI mark with its latest amendments 110 mm dia PVC REDUCER

10

287

2871

... More
CODE64 - Providing and fixing PVC -SWR- Nahani Trap 10cms multiple 10cms with all fitting arrangements and all necessary accessories complete

15

242

3630

... More
CODE65 - Providing and fixing PVC- SWR- P Trap 10cms multiple 10cms with all fitting arrangements and all necessary accessories complete

10

339

3399

... More
CODE66 - Providing and fixing floor mounted white vitreous china single piece double traps syphonic water closet of approved brand-make shape size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system including all fittings and fixtures with seat cover cistern fittings nuts bolts and gasket etc including making connection with the existing P-S trap complete in all respect as per directions of Engineer-in-Charge Hindware

6

15633

93799.2

... More
CODE67 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 multiple 260 multiple 350 mm and 340 multiple 410 multiple 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C P brass spreaders with brass unions and G.I clamps complete including painting of fittings and brackets cutting and making good the walls and floors wherever required - One urinal basin with 5 litre white PVC automatic flushing cistern

3

4899

14698.2

... More
CODE68 - Providing and fixing wash basin with C I brackets 15 mm C P brass pillar taps 32 mm C P brass waste of standard pattern including painting of fittings and brackets cutting and making good the walls wherever require- White Vitreous China Wash basin size 630 multiple 450 mm with a pair of 15 mm C P brass pillar taps

8

3390

27121.6

... More
CODE69 - Providing and fixing C P Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge

7

891

6237

... More
CODE70 - Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings

7

1565

10957.1

... More
CODE71 - Providing and fixing Stainless Steel A ISI 304 18-8 kitchen sink as per IS-13983 with C I brackets and stainless steel plug 40 mm including painting of fittings and brackets cutting and making good the walls wherever required - Kitchen sink with drain board -510 multiple 1040 mm bowl depth 250 mm

1

6179

6179.8

... More
CODE72 - Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete 32 mm dia

4

83

334.4

... More
CODE73 - Providing and fixing unplasticised PVC connection pipe with brass unions - 45 cm length 20 mm nominal bore

20

121

2420

... More
CODE74 - Providing and fixing 600 multiple 450 mm beveled edge mirror of superior glass - of approved quality- complete with 6 mm thick hard board ground fixed to wooden cleats with C P brass screws and washers complete

6

1342

8052

... More
CODE75 - Providing and fixing Pillar Cock made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete - Class Economy

10

1345

13453

... More
CODE76 - Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete - Class Economy

25

660

16500

... More
CODE77 - Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete - Class Economy

8

1228

9829.6

... More
CODE78 - Providing and fixing Exposed set for concealed stop cock made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete - Class Economy

5

662

3311

... More
CODE79 - Providing and fixing Single lever Bib cock Long Nose -Lifting type cold water cartridge- with wall flange made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete - Class Economy

3

1375

4125

... More
CODE80 - Providing and fixing Towel rail -Rectangular- made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete - Class Economy

5

656

3283.5

... More
CODE81 - Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete - Class Economy

10

602

6028

... More
CODE82 - Providing and fixing Bidet spray made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete - Class Economy

8

922

7383.2

... More
CODE83 - Providing and placing on terrace - at all floor levels - polyethylene water storage tank IS -12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank

2000

9

19800

... More
CODE84 - Open Conduit System - Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends junction boxes adhesive paste etc and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 19-20 mm dia 2 mm thick

270

75

20493

... More
CODE85 - Open Conduit System - Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends junction boxes adhesive paste etc and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 25 mm dia 2 mm thick

215

89

19156.5

... More
CODE86 - Concealed Conduit System - Supplying heavy gauge PVC conduitpipe mmdia mm thick confirming toIS2509 with suitable size bends metal-PVC Junction boxes adhesive paste etc and running before concreting the slab The conduit shouldbe tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures run with18 SWGGI fishwire wherever necessary 19-20 mm dia 2 mm thick

660

72

47968.8

... More
CODE87 - Concealed Conduit System - Supplying heavy gauge PVC conduitpipe mm dia mm thick confirming to IS2509 with suitable size bends metal - PVC Junction boxes adhesive paste etc and running before concreting the slab The conduit shouldbe tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures run with 18 SWGGI fishwire wherever necessary 25 mm dia 2 mm thick

375

85

32175

... More
CODE88 - Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends junction box elbows screwsat an interval of 300 mm as required 20 mm

115

30

3542

... More
CODE89 - Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs orphill plugs orrawl plugsand clampe dusing heavy gauges addlesatan interval of 300 mm using NF screws and on either end of the pipe terminated completely 20 mm

63

20

1316.7

... More
CODE90 - Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs orrawl plugsand clampe dusing heavy gauges addlesatan interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm

44

24

1064.8

... More
CODE91 - Supplying And Fixing S Hook made out of 14mmdia M S Rod 25 mm

15

57

858

... More
CODE92 - Supplying and flush mounting powder coated-galvanized metal box suitable for mounting modular switch plates The boxe should be firmly flush mounted after due groove cutting in Brick-Stone-C C wall 1-2 Way

79

151

11992.2

... More
CODE93 - Supplying and flush mounting powder coated-galvanized metal box suitable for mounting modular switch plates The boxe should be firmly flush mounted after due groove cutting in Brick-Stone-C C wall 3 Way

41

174

7170.9

... More
CODE94 - Supplying and flush mounting powder coated-galvanized metal box suitable for mounting modular switch plates The boxe should be firmly flush mounted after due groove cutting in Brick - Stone-C C wall 4-5 Way

24

194

4672.8

... More
CODE95 - Supplying and flush mounting powder coated-galvanized metal box suitable for mounting modular switch plates The boxe should be firmly flush mounted after due groove cutting in Brick-Stone-C C wall 6 Way

48

242

11616

... More
CODE96 - Supplying and flush mounting powder coated-galvanized metal box suitable for mounting modular switch plates The boxe should be firmly flush mounted after due groove cutting in Brick-Stone-C C wall 8 Way

59

287

16938.9

... More
CODE97 - Supplying and fixing surface-flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting inBrick-C Cwall including necessary rawl plugs Machine-NF screws etc complete 3 Way

23

136

3137.2

... More
CODE98 - Supplying and fixing surface-flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick-C Cwall including necessary rawl plugs Machine-NF screws etc complete 4 Way

23

150

3466.1

... More
CODE99 - Wiringfor lighting - powercircuitusingoneof FRLSPVCinsulated 1100V grade multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694-2010 1mm Sqr The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-2010 Clause 16.8 Temperature Index -IS 694-2010 Clause 16.13 Smoke Density -IS 694-2010 Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-2010 Clause 16.12

470

20

9823

... More
CODE100 - Wiringfor lighting - powercircuitusingoneof FRLSPVCinsulated 1100V grade multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694-2010 1.5mm Sqr The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-2010 Clause 16.8 Temperature Index -IS 694-2010 Clause 16.13Smoke Density -IS 694-2010 Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-2010 Clause 16.12

2215

28

63349

... More
CODE101 - Wiringfor lighting - powercircuitusingoneof FRLSPVCinsulated 1100V grade multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694-2010 2.5mm Sqr The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-2010 Clause 16.8 Temperature Index -IS 694-2010 Clause 16.13 Smoke Density -IS 694-2010 Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-2010 Clause 16.12

2095

46

96789

... More
CODE102 - Wiringfor lighting - powercircuitusingoneof FRLSPVCinsulated 1100V grade multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694-2010 4mm Sqr The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-2010 Clause 16.8 Temperature Index -IS 694-2010 Clause 16.13Smoke Density -IS 694-2010 Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-2010 Clause 16.12

220

69

15246

... More
CODE103 - Supplying and drawing UTP-CAT 6E LAN cable

1340

41

56012

... More
CODE104 - Supplying and Fixing of switch mounting rack with power manager and Cable manager 6U with 450mm depth

2

7674

15349.4

... More
CODE105 - Supplying fixing of Network Switches 48 Port Gigabyte manageable

1

53779

53779

... More
CODE106 - Supplying fixing of Network Switches 48 port 10-100 Switch

1

16500

16500

... More
CODE107 - Supplying and fixing of I-O socket with back box Single I-O

26

539

14014

... More
CODE108 - Supplying and fixing of I-O socket with back box Double I-O

12

605

7260

... More
CODE109 - Supplying and Fixing of ms Cat 6 Patch Cable -1 m

6

246

1478.4

... More
CODE110 - Supplying and Fixing of ms Cat 6 Patch Cable - 2 m

6

282

1696.2

... More
CODE111 - Supplying and Fixing of ms Cat 6 Patch Cable - 3 m

20

364

7282

... More
CODE112 - Supplying and Fixing of Patch panel for LAN cabling 48 Port 10-100 patch panel

2

15687

31374.64

... More
CODE113 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws bolts nuts etc complete on the existing metal-PVC box 1 to 2 Module

79

150

11905.3

... More
CODE114 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws bolts nuts etc complete on the existing metal-PVC box 3 Module

41

177

7261.1

... More
CODE115 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws bolts nuts etc complete on the existing metal-PVC box 4 Module

24

192

4620

... More
CODE116 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required no of machine screws bolts nuts etc complete on the existing metal-PVC box 6 Module

48

257

12355.2

... More
CODE117 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws bolts nuts etc complete on the existing metal-PVC box 8 Module

59

312

18431.6

... More
CODE118 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A One Way Switch

459

112

51499.8

... More
CODE119 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Two Way Switch

34

182

6208.4

... More
CODE120 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped Fan Regulator Two Module

47

392

18456.9

... More
CODE121 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16A One Way Switch

11

198

2178

... More
CODE122 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Bell Push

15

194

2920.5

... More
CODE123 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32A DP Switch

16

358

5737.6

... More
CODE124 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6-16A Universal Socket

184

259

47766.4

... More
CODE125 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 TV-Telephone Socket

18

171

3088.8

... More
CODE126 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 129 RJ45-I O Outlet Cat-6

4

370

1482.8

... More
CODE127 - Supplying 4mm thick white plastic plate and covering for junction boxes of size Mm conduit using necessary machine screws 60mm

50

8

440

... More
CODE128 - Supplying 4mm thick white plastic plate and covering for junction boxes of size Mm conduit using necessary machine screws 8-90 mm

75

16

1237.5

... More
CODE129 - Supplying 4mm thick white plastic plate and covering for junction boxes of size Mm conduit using necessary machine screws 110mm

75

23

1732.5

... More
CODE130 - Supplying And fixing-replacing of 6-16-32A electrical accessories on existing switch board 6A Bell Buzzer

15

143

2145

... More
CODE131 - Supplying and fixing regular MCCB distribution Panel confirming to IS-IEC 61439 - 3 and IK09 tested as per IS-IEC 62262 with minimum IP43 protection provided with Polyurethane -PUR- gasket with suitable earthing system on wall-wood board-flush mounting using required cl A bolts nuts etc with provision for fixing of suitable type capacity MCCBs as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc complete with a provision for fixing of single-three phase suitable capacity MCBs as outgoings confirming to IS-IEC 60898 - 2.12 Way

1

17081

17081.9

... More
CODE132 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicat or ON-OFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SP

25

456

11412.5

... More
CODE133 - Supplying and fixing regular MCB distribution boards on wall-wood board - flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCBs single phase -3 phase- single door with powder coated painting Made out of 14SWG MS enclosure I - Single Door 6 Way SP and N

1

1304

1304.6

... More
CODE134 - Supplying and fixing regular MCB distribution boards on wall wood board - flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCBs single phase -3 phase- single door with powder coated painting Made out of 14 SWG MS enclosure II - Double Door 6 Way SP and N

1

1970

1970.1

... More
CODE135 - Supplying of feet-PVC Batten with integrated LED tubeW with high quality diffuser with Life of 25000 burning hours and 70percentage lumen maintenance with CRI graterthan 80 Power Input 220-240Vat 50-60Hz and Power factor grater than 0.9 along with CE approved 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 multiple 2 - 9-10 W

10

606

6061

... More
CODE136 - Supplying and fixing of retrofit type - LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K CRI lesser than 70 percentage efficacy grater than 80 lumen per W life grater than 25000 burning hours and Compliance to IS 10322-IEC 60598 LM 79 and LM 80 The LED are driven by HF electronic driver integrated in the system with PF grater than 0.95 power loss should lesser than 5percentage of lamp Wage short circuit and open circuit protection to be integrated in the circuit THD less than 20 percentage Life as per LM 79 The operating input voltage should be between 130 to 275 V BIS Approved and Tested by NABL-CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 9W 6500K

13

169

2202.2

... More
CODE137 - Supplying of feet-PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70 percentage lumen maintenance with CRI grater than 80 Power Input- 220-240V at 50-60Hz and Power factor grater than 0.9 along with CE approved 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 multiple 4 - 20-22 W

58

759

44022

... More
CODE138 - Fixing all types and all capacities of 1 multiple 4 - 2 multiple 2 LED Light fittings indoor on the wall - ceiling - rafters - girders with necessary supporting frame using 2310.0076 twin twisted PVC insulated wires required Nos of round blocks and clamps

81

539

43659

... More
CODE139 - Supplying of recess mounting non integral type- LED w luminaire comprising of pressure decast-extruded aluminium housing with spring loaded false ceiling clamps Power LEDs with CCT 6500 degree K CRI grater than 70percentage efficacy grater than 100 lumen per W 120degree beam spread life grater than 25000 burning hours and Compliance to IS 10322-IEC 60598 LM 79 and LM 80 The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly with PF grater than 0.95 power loss should lesser than5percentage of lamp Wage short circuit and open circuit protection to be integrated in the circuit THD less than 20 percentage Life as per LM 79 The operating input voltage should be between 130 to 275 V BIS Approved and Tested by NABL-CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition LED modular down light 2 multiple2 36 W

40

5008

200332

... More
CODE140 - Supplying of recess mounting non integrated type LED down light W luminaire comprising of pressure decast- extruded aluminium housing with spring loaded false ceiling clamps LED of Power-COB with CCT 6500 degree K CRI lesser than 70percentage efficacy lesser than100 lumen per W 120 degree beam spread life lesser than 25000 burning hours and Compliance to IS10322-IEC 60598 LM 79 and LM 80 The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly with PF grater than 0.95 power loss should lesser than 5 percentage of lamp Wage short circuit and open circuit protection to be integrated in the circuit THD less than 20 percentage Life as per LM 79 The operating input voltage should be between 130 to 275 V BIS Approved and Tested by NABL-CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 5-6W

28

885

24794

... More
CODE141 - Supplying of recess mounting non integrated type LED down light- W luminaire comprising of pressure decast- extruded aluminium housing with spring loaded false ceiling clamps LED of Power-COB with CCT 6500 degree K CRI grater than 70 percentage efficacy grater than100 lumen per W 120degree beam spread lifegrater than 25000 burning hours and Compliance to IS10322-IEC 6059 LM 79 and LM 80 The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly with PF grater than 0.95 power loss shouldlesser than 5percentage of lamp Wage short circuit and open circuit protection to be integrated in the circuit THD less than 20percentage Life as per LM 79 The operating input voltage should be between 130 to 275 V BIS Approved and Tested by NABL-CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 15-18w

30

1838

55143

... More
CODE142 - Fixing all types and all capacities of fluorescent -false ceiling - spot light - CFL - LED fittings indoor on the wall- ceiling - rafters - girders using 23-0.0076 twin twisted PVC insulated wires required Nos of round blocks and clamps On wall- ceiling Rafter Girders

98

134

13151.6

... More
CODE143 - Supplying exhaust fan of 1440 RPMof 300mm-12- sizewith bracket blades complete for light duty suitable tooperate on 230V 50Hz AC Supply

8

149

1193.6

... More
CODE144 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A ceiling rose with sufficient length of 23-0.0076 inch PVC insulated twin core wire

8

492

3936

... More
CODE145 - Supplying capacitor type ceiling fan complete with down rod blades shackle canopies etc for operation on 230 50cycles Single phase Acsupply conforming to ISS-374-1979 andwith double ball bearing system 48 Sweep -1200 mm- Regular model

47

3282

154272.8

... More
CODE146 - Fixing a ceiling - Wall mounting fan of all capacities and all types to the existing S hook with fan regulator to the existing board together with supplying and fixing 5 A ceiling rose necessary length of 23 - 0.0076 inch PVC insulated twin twisted copper wire and wiring

47

188

8840.7

... More
CODE147 - Supplying -TR split Air conditioners suitable for operationon A-C supply single phase 50Hz 230V with hermetically sealed compress or with air cooled condenser motor capacitor and start run capacitors relay and overload protect or internal unit with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube Highwall chorded-cordless suitable capacity 3 core sheathed- PVC copper cable and a battery operated wireless remote unit 5star 1.5 Ton capacity

10

52451

524513

... More
CODE148 - Supplying, erecting testing and commissioning of ON-LINE UPS system suitable for operation on 230V 50Hz A-C supply with isolation transformer all accessories complete and Excluding batteries and wiring complete 3 kVA ON LINE UPS

1

42590

42590.9

... More
CODE149 - Supplying installation testing and commissioning of 12VDC AH batteries in polypropylene container for UPS Sealed maintenance free batteries

2

5731

11462



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.