Karnataka Industrial Areas Development Board Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Industrial Areas Development Board - KIADB Tender

Works
Civil And Construction
Water Storage And Supply
Opening Date19 Apr 2025
Closing Date2 May 2025
Tender Amount₹ 21,87,48,845.76 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code118 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. in all other structures. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

0.54

82961

44799.237

... More
code44 - Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete.150mm dia.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

2487

2487.45

... More
code45 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) 400mm dia PN-10. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

2

131635

263270.7

... More
code19 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

39.65

7369

292215.3455

... More
code55 - Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. MS angle of 65x65x10mm. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

24

5041

120985.2

... More
code75 - Supply and fixing of DI Double flanged wafer type ( Concentric) / double eccentrically disc, Resilent seated Butterfly valves confoming to BS EN 593 / IS 13095 with shaft shall be of stainless steel AISI 410/431/420 and renewable soft seal on the disc and body seat face of nickel weld overlay micro finished/Bolted External Seat of SS 304 / CF8 with Powder or liquid epoxy coating with minimum thickness of 250 microns applied on both body and disc inside and outside. Fce to face dimensions as per EN 558-1 Basic series 14 (DIN 3203 F4) or AWWA C 504 : 80 or IS 13095. The valves shall be supplied along with the required number of standard make galvanized Bolts and nuits. The flange drilling standard is IS 1538. hence, drilling of hole in the valves shall match with the pipe flange drilling standard, the valves are to be suitabale for buried operaion with the gear box sealed and lubricated for life time opration. ( All the drilled holes in the body shall be of though holes, no tapped holes will be allowed).Eccentric Butterfly Valves. 200mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

34312

34312.95

... More
code58 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 m wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. In all kinds of soil. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

37592.75

275

10341765.525

... More
code12 - Providing bedding for the pipeline trenches in black cotton and rock reaches including watering and consolidation by punners etc. complete with all lead and lift with: M -Sand. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

120

2124

254898

... More
code14 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia.with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroidal sealing rings (minimum 2 “O” rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minium coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set,galvanized bolts & nuts and rubber insertions etc. but excluding earth work. 400mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

3

504625

1513877.4

... More
code35 - Supplying, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DIflanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete. C.I. flanged pipes .400mm dia for inlet & overflow. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

45

20594

926761.5

... More
code66 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6, 225 mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1353

1482

2005957.8

... More
code92 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6,225mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

3093

1482

4585681.8

... More
code11 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 m wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. Ordinary/Soft rock (without requiring blasting). complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

358.4

476

170849.28

... More
code39 - Providing Ductile Iron Push on special confirming to IS 9523:2000 - All Double Socket Duck Foot DI Bends. 300mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

2

19236

38472

... More
code26 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For beams from 10 to 15m. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

3.75

13822

51834

... More
code46 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) 300mm dia PN-10. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

63341

63341.25

... More
code36 - Supplying, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DIflanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete. C.I. flanged pipes .300mm dia for outlet. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

20

12414

248283

... More
code38 - Providing Ductile Iron Push on special confirming to IS 9523:2000 - All Double Socket Duck Foot DI Bends.150mm dia . complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

2

5420

10840.2

... More
code59 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 m wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.Soft rock. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

4176.97

476

1991161.599

... More
code93 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6,250mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

351

1791

628746.3

... More
code72 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.).250mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

88

48815

4295768.4

... More
code07 - Supply and fixing of Horizontal Mechanical Woltman type hemetically sealed water meters with copper Glass register with IP 68 protection. The meter shall be removable mechanism type manufactured as ISO 4064-1: 1993 with MID certification. The meters shall be capable of transmitting consumption data on daily basis to central server through GSM/GPRS. The meter interface unit shall be fitted to the meter without wire. The consumption data shall be collected , stored and analysed by data logger. The data logger should provide data like flow rate, total flow, consumption analyses, reverse flow, meter tampering, daily flow distribution, leakage detection. The data logger shall also send alams on blocked meter, flow rate above limit, pressure below or above limits.300mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

306351

306351.15

... More
code41 - Providing Ductile Iron Push on special confirming to IS 9523:2000 - Socketed D.I. Equal Tees.300mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

2

14516

29032.5

... More
code16 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

3276.08

168

550381.44

... More
code02 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 m wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.in all kinds of soil. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

680.4

275

187178.04

... More
code27 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. for beam from 12 to 15m. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

36.48

13822

504241.152

... More
code47 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) 150mm dia PN-10. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

18364

18364.5

... More
code96 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-10:150mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

15

18364

275467.5

... More
code61 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6, 125 mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

2126

514

1093827

... More
code80 - Supply and fixing of Horizontal Mechanical Woltman type hemetically sealed water meters with copper Glass register with IP 68 protection. The meter shall be removable mechanism type manufactured as ISO 4064-1: 1993 with MID certification. The meters shall be capable of transmitting consumption data on daily basis to central server through GSM/GPRS. The meter interface unit shall be fitted to the meter without wire. The consumption data shall be collected , stored and analysed by data logger. The data logger should provide data like flow rate, total flow, consumption analyses, reverse flow, meter tampering, daily flow distribution, leakage detection. The data logger shall also send alams on blocked meter, flow rate above limit, pressure below or above limits.300mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

46

306351

14092152.9

... More
code91 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6,200mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

3075

1197

3680775

... More
code08 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge

688.64

168

115691.52

... More
code114 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

938.52

168

157671.36

... More
code05 - Providing and laying Ductile Iron pipes of class K9 conforming to IS 8329:2000 with latest amendments, conveyiing to work site, rolling and lowering into trenches, laying true to line, level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations, cutting of pipes wherever necessary, jointing with DI specials (excluding cost of specials) and rubber gaskets, cleaning the socket and spigot end with soap solution, applying soft soap to the socket and spigot ends before insertion of rubber gaskets, jacking and fixing in perfect conditions etc. The cost to include soap solution, soft soap, waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. (The contractor will make his own arrangements for water for testing. Earth work excavation in trenches to be measured and paid for seperately) Note: In sewerage projects for internal cement mortal lining ( CML ) of DI pipes, if High Alumina Cement ( HAC ) as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement ( SRC ), the cost of pipes may be increased by 5-6% from the prices listed.350 mm dia DI K-9.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

700

6325

4427640

... More
code10 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 m wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. In all kinds of soil. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

3225.6

275

887362.56

... More
code57 - Distribution network Zone1: Earthwork excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

10442.43

508

5306842.926

... More
code102 - Supply and fixing of Horizontal Mechanical Woltman type hemetically sealed water meters with copper Glass register with IP 68 protection. The meter shall be removable mechanism type manufactured as ISO 4064-1: 1993 with MID certification. The meters shall be capable of transmitting consumption data on daily basis to central server through GSM/GPRS. The meter interface unit shall be fitted to the meter without wire. The consumption data shall be collected , stored and analysed by data logger. The data logger should provide data like flow rate, total flow, consumption analyses, reverse flow, meter tampering, daily flow distribution, leakage detection. The data logger shall also send alams on blocked meter, flow rate above limit, pressure below or above limits.100mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

100

73551

7355145

... More
code31 - Ladder inside the container: Providing anodized aluminium ladder using 65mm x 32mm x 3.0mm ‘C’ section for ladder side channel x 25mm dia., flutal pipe for Rungs at 250mm c/c ladder fixed at an angle of 70 degrees to horizontal including necessary 25mm dia., G.I. shutters with necessary G.I. fasteners for bracing the ladders to the Tank walls to prevent buckling of the ladder with necessary (M-15) bed for embedding the ladder bottom complete. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

5.5

5355

29452.5

... More
code88 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6,140mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

2182

622

1358622.3

... More
code86 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6,110mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

37724

446

16834335

... More
code107 - Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey.For Road Crossing 500mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

300

2722

816795

... More
code89 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6,160mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

2359

799

1884958.95

... More
code115 - Valve Chamber2:Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soil. Depth upto 3m complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

17.28

107

1850.688

... More
code33 - Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

2247

2247

... More
code49 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.from 0 to 5m. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

156.73

366

57433.7085

... More
code18 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 40 mm nominal size graded crushed coarse aggregates. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

9.43

6463

60953.634

... More
code104 - Supply and fixing of Horizontal Mechanical Woltman type hemetically sealed water meters with copper Glass register with IP 68 protection. The meter shall be removable mechanism type manufactured as ISO 4064-1: 1993 with MID certification. The meters shall be capable of transmitting consumption data on daily basis to central server through GSM/GPRS. The meter interface unit shall be fitted to the meter without wire. The consumption data shall be collected , stored and analysed by data logger. The data logger should provide data like flow rate, total flow, consumption analyses, reverse flow, meter tampering, daily flow distribution, leakage detection. The data logger shall also send alams on blocked meter, flow rate above limit, pressure below or above limits.200mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

6

108654

651924

... More
code120 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

15.84

168

2661.12

... More
code22 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For beams from 0 to 5m. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

7.02

11771

82637.7552

... More
code70 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.).150mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

5

18364

91822.5

... More
code56 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

237.9

279

66445.47

... More
code95 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-10:100mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

100

11428

1142820

... More
code34 - Providing and fixing gauge with iron sheet or enamelled guage plate of 3mm to 4mm thick, 0.23 M width with copper floats indicators and flexible nylone wires, painting figures with approved enamel paint etc. with all lead and lifts, complete for: Enamelled guage plate for 2.5 Mtrs depth.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

4886

4886.7

... More
code73 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.).300mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

46

63341

2913697.5

... More
code74 - Supply and fixing of DI Double flanged wafer type ( Concentric) / double eccentrically disc, Resilent seated Butterfly valves confoming to BS EN 593 / IS 13095 with shaft shall be of stainless steel AISI 410/431/420 and renewable soft seal on the disc and body seat face of nickel weld overlay micro finished/Bolted External Seat of SS 304 / CF8 with Powder or liquid epoxy coating with minimum thickness of 250 microns applied on both body and disc inside and outside. Fce to face dimensions as per EN 558-1 Basic series 14 (DIN 3203 F4) or AWWA C 504 : 80 or IS 13095. The valves shall be supplied along with the required number of standard make galvanized Bolts and nuits. The flange drilling standard is IS 1538. hence, drilling of hole in the valves shall match with the pipe flange drilling standard, the valves are to be suitabale for buried operaion with the gear box sealed and lubricated for life time opration. ( All the drilled holes in the body shall be of though holes, no tapped holes will be allowed).Scour Valve - Wafer Type Butter Fly Valves. 100mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

20

14416

288330

... More
code29 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For top dome, ring beam, crown beam, pillars for pipe raining etc., complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

12.96

13956

180877.536

... More
code67 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6, 250 mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

875

1791

1567387.5

... More
code99 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-10:300mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

63341

63341.25

... More
code94 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6,315mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

278

2737

760983.3

... More
code04 - Providing bedding for the pipeline trenches in black cotton and rock reaches including watering and consolidation by punners etc. complete with all lead and lift with: M -Sand. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

26.25

2124

55758.9375

... More
code84 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 m wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.In all kinds of soil.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

27283.54

275

7505701.854

... More
code50 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.from 5 to 10m. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

272.72

410

111929.7424

... More
code113 - Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

373

2247

838131

... More
code20 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For column below GL.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

3.48

12507

43526.1

... More
code03 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 m wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.Ordinary/Soft rock (without requiring blasting). complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

75.6

476

36038.52

... More
code48 - Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

699.47

93

65365.4715

... More
code28 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For side wall from 15 to 18m. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

23.92

9595

229516.2272

... More
code100 - Supply and fixing of DI Double flanged wafer type ( Concentric) / double eccentrically disc, Resilent seated Butterfly valves confoming to BS EN 593 / IS 13095 with shaft shall be of stainless steel AISI 410/431/420 and renewable soft seal on the disc and body seat face of nickel weld overlay micro finished/Bolted External Seat of SS 304 / CF8 with Powder or liquid epoxy coating with minimum thickness of 250 microns applied on both body and disc inside and outside. Fce to face dimensions as per EN 558-1 Basic series 14 (DIN 3203 F4) or AWWA C 504 : 80 or IS 13095. The valves shall be supplied along with the required number of standard make galvanized Bolts and nuits. The flange drilling standard is IS 1538. hence, drilling of hole in the valves shall match with the pipe flange drilling standard, the valves are to be suitabale for buried operaion with the gear box sealed and lubricated for life time opration. ( All the drilled holes in the body shall be of though holes, no tapped holes will be allowed) For PN-10.100mm dia. Scour Valve - Wafer Type Butter Fly Valves. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

28

14416

403662

... More
code17 - OHT: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

286.98

107

30735.558

... More
code117 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

6.76

6639

44880.654

... More
code65 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6, 200 mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

451

1197

539847

... More
code108 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

29530.53

168

4961129.04

... More
code54 - Supplying and fixing 40mm dia. GI pipe medium duty pipes hand railing 3 rows fixed to RCC 1:2:4 vibrated post of 150x150mm at bottom and 100x150mm at top, placed at 2 Mtrs. intervals for a height of 750mm including curing, painting GI pipes with two coats of anticorrosive steel paint over a primer coat etc. with all lead lift etc. (The rate per meter is for 3 rows of GI pipes and RCC post).complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

88

1393

122614.8

... More
code79 - Supply and fixing of Horizontal Mechanical Woltman type hemetically sealed water meters with copper Glass register with IP 68 protection. The meter shall be removable mechanism type manufactured as ISO 4064-1: 1993 with MID certification. The meters shall be capable of transmitting consumption data on daily basis to central server through GSM/GPRS. The meter interface unit shall be fitted to the meter without wire. The consumption data shall be collected , stored and analysed by data logger. The data logger should provide data like flow rate, total flow, consumption analyses, reverse flow, meter tampering, daily flow distribution, leakage detection. The data logger shall also send alams on blocked meter, flow rate above limit, pressure below or above limits.250mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

88

143118

12594397.2

... More
code37 - Supplying, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DIflanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete. C.I. flanged pipes .150mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

20

5048

100968

... More
code105 - Supply and fixing of Horizontal Mechanical Woltman type hemetically sealed water meters with copper Glass register with IP 68 protection. The meter shall be removable mechanism type manufactured as ISO 4064-1: 1993 with MID certification. The meters shall be capable of transmitting consumption data on daily basis to central server through GSM/GPRS. The meter interface unit shall be fitted to the meter without wire. The consumption data shall be collected , stored and analysed by data logger. The data logger should provide data like flow rate, total flow, consumption analyses, reverse flow, meter tampering, daily flow distribution, leakage detection. The data logger shall also send alams on blocked meter, flow rate above limit, pressure below or above limits.250mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

4

143118

572472.6

... More
code81 - Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey.For Road Crossing 250mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

200

1157

231420

... More
code87 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6,125mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

3813

514

1961788.5

... More
code111 - Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

439.21

6639

2915981.0715

... More
code01 - Raising Main: Earthwork excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

189

508

96049.8

... More
code77 - Supply and fixing of Horizontal Mechanical Woltman type hemetically sealed water meters with copper Glass register with IP 68 protection. The meter shall be removable mechanism type manufactured as ISO 4064-1: 1993 with MID certification. The meters shall be capable of transmitting consumption data on daily basis to central server through GSM/GPRS. The meter interface unit shall be fitted to the meter without wire. The consumption data shall be collected , stored and analysed by data logger. The data logger should provide data like flow rate, total flow, consumption analyses, reverse flow, meter tampering, daily flow distribution, leakage detection. The data logger shall also send alams on blocked meter, flow rate above limit, pressure below or above limits.150mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

5

88334

441672

... More
code24 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For beams from 5 to 10m. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

8.39

13448

112829.2234

... More
code15 - Installation, Commissioning and Testing (for receipt of readings to the Bulk Flow Metering and Monitoring System SCADA Centre ) of HART output ( flow rate and Totalizer) based Electromagnetic Induction Bulk Flow Meters approved make to the feeder mains . The flow meter shall be full bore type shall be installed as per Manufacturer Recommendations. The Electromagnetic Induction Bulk Flow meters shall comply with the specifications mentioned. The maximum allowable measuring error shall be +/- 0.2 % of the volume. The meter transmitter shall convert the HART Output to produce reliable and correct output. The data to the remote server shall be transmitted with HART Protocol Remote Telemetry Device(RTU)..The Remote Telemetry Devices to Monitor the Real Time Water Flow and Totalizer by converting Output from Bulkflow meter (the Output is of HART output). The transmitter or the modem provided shall be of HART ( Highway Addressable Remote Transduser) type, which shall work in the master mode to read the totalizer and flow rate including panel box. The Remote Telemetry Devices shall have atleast the following specification.All data will be read via HART protocol and transmitted to the client Server via FTP Hardware:: Power: 12V DC, Connectivity: Builtin 3G with 2G fall back connectivity, Input HART: Builtin HART Modem in Master Mode to read flow rate and totalizer value, Digital inputs to connect to Door sensor and AC relays, One Relay output to switch on Light inside the enclosure, One MicroUSB port to configure the gateway, Customized sheet metal box, Operating Temperature: -10 to +70 Deg C operating, High Gain GPRS Antennae. Software :: Linux based Operating System, Programmable via C and Node.js, ReAP Framework supporting HTTP and FTP, Option to configure 3 FTP Sites for data transfer, Option to configure 1 HTTP url for data transfer, Automatic Upgradation of Firmware and Configuration Software via Over the Air. The cost includes all materials,accessories,labour complete. Battery Operated.400mm dia.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

405126

405126.75

... More
code103 - Supply and fixing of Horizontal Mechanical Woltman type hemetically sealed water meters with copper Glass register with IP 68 protection. The meter shall be removable mechanism type manufactured as ISO 4064-1: 1993 with MID certification. The meters shall be capable of transmitting consumption data on daily basis to central server through GSM/GPRS. The meter interface unit shall be fitted to the meter without wire. The consumption data shall be collected , stored and analysed by data logger. The data logger should provide data like flow rate, total flow, consumption analyses, reverse flow, meter tampering, daily flow distribution, leakage detection. The data logger shall also send alams on blocked meter, flow rate above limit, pressure below or above limits.150mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

15

88334

1325016

... More
code23 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For columns from 5 to 10m. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

6.64

14288

94876.0384

... More
code110 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

63.04

6288

396423.888

... More
code42 - Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete.400mm dia.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

2

9939

19878.6

... More
code109 - Valve Chamber1:Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soil. Depth upto 3m complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

939.96

107

100669.716

... More
code101 - Supply and fixing of DI Double flanged wafer type ( Concentric) / double eccentrically disc, Resilent seated Butterfly valves confoming to BS EN 593 / IS 13095 with shaft shall be of stainless steel AISI 410/431/420 and renewable soft seal on the disc and body seat face of nickel weld overlay micro finished/Bolted External Seat of SS 304 / CF8 with Powder or liquid epoxy coating with minimum thickness of 250 microns applied on both body and disc inside and outside. Fce to face dimensions as per EN 558-1 Basic series 14 (DIN 3203 F4) or AWWA C 504 : 80 or IS 13095. The valves shall be supplied along with the required number of standard make galvanized Bolts and nuits. The flange drilling standard is IS 1538. hence, drilling of hole in the valves shall match with the pipe flange drilling standard, the valves are to be suitabale for buried operaion with the gear box sealed and lubricated for life time opration. ( All the drilled holes in the body shall be of though holes, no tapped holes will be allowed) For PN-10.200mm dia. Eccentric Butterfly Valves. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

34309

34309.8

... More
code09 - Raising Main Zone2:Earthwork excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge

896

508

455347.2

... More
code64 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6, 180 mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

2723

984

2681882.7

... More
code97 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-10:200mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

6

30144

180866.7

... More
code119 - Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

3

2247

6741

... More
code116 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

0.97

6288

6099.7965

... More
code06 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia.with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroidal sealing rings (minimum 2 “O” rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minium coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set,galvanized bolts & nuts and rubber insertions etc. but excluding earth work.300mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

192312

192312.75

... More
code32 - Providing and fixing RCC final and ventilators as per approved design and specifications with form works and protected with wire mesh. The plinth to be of RCC circular pillars and canopy with an ornamental finish at top. The first 22.5 cms height to be covered with RCC panelling as per detailed drawings etc. with all lead and lifts and excluding reinforcement steel. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

6732

6732.6

... More
code82 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour. complete as per specifications.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

40798.67

168

6854176.56

... More
code98 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-10:250mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

4

48815

195262.2

... More
code21 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For columns from 0 to 5m. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

7.37

12559

92559.83

... More
code13 - Providing and laying Ductile Iron pipes of class K9 conforming to IS 8329:2000 with latest amendments, conveyiing to work site, rolling and lowering into trenches, laying true to line, level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations, cutting of pipes wherever necessary, jointing with DI specials (excluding cost of specials) and rubber gaskets, cleaning the socket and spigot end with soap solution, applying soft soap to the socket and spigot ends before insertion of rubber gaskets, jacking and fixing in perfect conditions etc. The cost to include soap solution, soft soap, waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. (The contractor will make his own arrangements for water for testing. Earth work excavation in trenches to be measured and paid for seperately) Note: In sewerage projects for internal cement mortal lining (CML) of DI pipes, if High Alumina Cement (HAC) as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement (SRC), the cost of pipes may be increased by 5-6% from the prices listed.400 mm dia DI K-9.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

3200

7686

24595200

... More
code90 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6,180mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1557

984

1533489.3

... More
code43 - Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete.300mm dia.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

5965

5965.05

... More
code25 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For columns from 10 to 15m. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

6.74

14686

98985.662

... More
code51 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.from 10 to 15m. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

270.03

417

112805.0325

... More
code69 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.).100mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

54

11428

617122.8

... More
code60 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6, 110 mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

61689

446

27528716.25

... More
code30 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.For all other structures. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

23.46

82961

1946277.963

... More
code63 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6, 160 mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

2416

799

1930504.8

... More
code62 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984- 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE100-PN6, 140 mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

2856

622

1778288.4

... More
code53 - Supplying and fixing lightening arrestor with aluminium strip 25mm x 3mm size including finial and grounding, aluminium strip to be embeded in one of the columns in and independent GI conduit of 40mm dia. pipe suitably jointed by collars with all specials with all lead and lifts etc. complete for Over Head Tanks upto 15m staging.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

14583

14583.45

... More
code112 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

35.14

82961

2915268.867

... More
code71 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.).200mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

30144

30144.45

... More
code83 - Distribution network zone 2:Earthwork excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.complete as per specifications.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

7578.76

508

3851525.832

... More
code78 - Supply and fixing of Horizontal Mechanical Woltman type hemetically sealed water meters with copper Glass register with IP 68 protection. The meter shall be removable mechanism type manufactured as ISO 4064-1: 1993 with MID certification. The meters shall be capable of transmitting consumption data on daily basis to central server through GSM/GPRS. The meter interface unit shall be fitted to the meter without wire. The consumption data shall be collected , stored and analysed by data logger. The data logger should provide data like flow rate, total flow, consumption analyses, reverse flow, meter tampering, daily flow distribution, leakage detection. The data logger shall also send alams on blocked meter, flow rate above limit, pressure below or above limits.200mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

1

108654

108654

... More
code76 - Supply and fixing of Horizontal Mechanical Woltman type hemetically sealed water meters with copper Glass register with IP 68 protection. The meter shall be removable mechanism type manufactured as ISO 4064-1: 1993 with MID certification. The meters shall be capable of transmitting consumption data on daily basis to central server through GSM/GPRS. The meter interface unit shall be fitted to the meter without wire. The consumption data shall be collected , stored and analysed by data logger. The data logger should provide data like flow rate, total flow, consumption analyses, reverse flow, meter tampering, daily flow distribution, leakage detection. The data logger shall also send alams on blocked meter, flow rate above limit, pressure below or above limits.100mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

54

73551

3971778.3

... More
code85 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 m wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.Ordinary/Soft rock (without requiring blasting).complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

3031.5

476

1445116.05

... More
code52 - Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to RCC structures like floor and walls of reservoirs, sewer, effluent and water treatment plants, over head tanks, etc. prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry 2 parts water) for horizontal and vertical surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI - 212-3R-2010 ie. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 Bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self healing of cracks upto a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineer in charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal and vertical surfaces in two coats @ 0.70 kg per sqm per coat.complete with all lead and lift etc, as per specification and as per directed by the Engineer in charge.

168.94

454

76808.571



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.