Indian Institute Of Science Tender
... More
The IISC has issued a formal invitation for competitive bids for the Indian Institute Of Science project, for The Work Of Removing And Refixing Of Existing Bs Slabs Pathway Between Silver Oak Marg To in Bengaluru Urban, Karnataka. The bid opening date for this tender is 27-05-2025 and the last date for bid submission is 02-06-2025. Interested bidders for Indian Institute Of Science tender can download the important documents here to check the tender amount, scope of work, eligibility criteria and technical requirements.
Indian Institute Of Science - IISC Tender
Civil Works Others
Eprocure
Opening Date27 May 2025
Closing Date2 Jun 2025
Tender AmountRefer Documents
Costs
EMD
0Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
The Work Of Removing And Refixing Of Existing Bs Slabs Pathway Between Silver Oak Marg To
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_IISC_861906_1Tender No
IISc/WORK-22/TSC-01/2025-26Tender Authority
Indian Institute Of Science ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Shifting of Burnt stone inside IISc Campus.For Tractor-Trolley
4
1
-
... More
Supply and fixing of LED Bollard light fitting of ...W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate /clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition.
Note: Equivalent to model: BCP150 of Philips
Make: Philips, Crompton, Havells, Bajaj, Wipro
8W/10W 0.5m Height
30
1
-
... More
Supply of materials- 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, Copper Control Cable as per IS- 554 (Part-1)
4c x 2.5 sq mm Cu
300
1
-
... More
Laying of one number of PVC insulated or PVC sheathed/ XLPE power cable of 1.1kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering.
up to 35 sq mm
300
1
-
... More
Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cut outs and other equipment's on the meter board using 40mm dia 2.90 mm thick G Ipipe 2.5m long buried in a pit .The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GI wire of size as per lSI specification 7.3.3.of IS732 using 12mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia
1
1
-
... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre belowground level for conductor earth electrode, includingconnection/ termination with GI thimble etc. as required.
20
1
-
... More
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates
1.62
1
-
... More
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
24
1
-
... More
Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m
0.81
1
-