Rural Water Supply And Sanitation Department Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Rural Water Supply And Sanitation Department - RWSS Tender

Civil And Construction
Civil Works Others
Opening Date13 Jul 2022
Closing Date21 Jul 2022
Tender Amount₹ 51,43,812 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications (PWD SR-2021-2022, P.No-7 -1.10)

438.75

-

59950.8

... More
Wet Mix Macadam (Plant mix method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with Grader in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. Laying Using Grader Ref MORTH 406-B (PWD SR-2021-2022, P.No-24, I.No : 4.27)

0.45

-

1019.59

... More
Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14- days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. (SR-2021-2022, P.No-138, I-20.29)

0.68

-

5207.06

... More
CIPET TEST, Dimensions

1

-

500

... More
CIPET TEST Melt flow rate at 190 C/5 Kg

1

-

1100

... More
CIPET TEST Density

1

-

1125

... More
CIPET TEST Reversion Test

1

-

1000

... More
CIPET TEST Elongation at Break

1

-

1100

... More
CIPET TEST Carbon black content

1

-

925

... More
CIPET TEST Carbon Black dispersion

1

-

700

... More
CIPET TEST Oxidation Induction Time

1

-

2200

... More
CIPET TEST Internal Pressure Creep rupturetest of pipe for 48 hoursat 80 degree celsius

1

-

1600

... More
Providing house connection with excavation in all types of soils cutting with machine cutter without damaging the other utilities and supplying and laying of MDPE pipe (PE80) -PN 12.5 manufactured in accordance with ISO 4427 - 1996 with minimum required strength of 8 Mpa, hydraulic design stress of 6.3 Mpa and with minimum wall thickness of 2.3mm /GI pipe by making the bore of 15mm dia. size on the distribution mains using drilling bits or machines only and laying the pipe line at a depth not less than 0.45 mtrs. from the road surface, including providing 40mm dia. “A” class GI pipe as casing over the MDPE pipe from the bore point and upto the entrance of the premises and removing the stone slab covering of the drain and dismantling the size stone masonry wherever necessary and making bore in the wall of the premises. On entering the premises, connection should be continued with 20mm GI pipe by making “U” shape for the meter point below the ground level by making pit with sufficient space for the easy installation and removal of the water meter and providing vertical stand pipes on both sides of the meter. The connection should be secured firmly on thedistribution main pipe with SS / Brass ferrule of size 1/2” x 3/4” and fixing the union joint and gate valve / stop cock before the meter point and a reflex valve / non-return valve should be fixed on the connection after the meter point. (All these fixtures should be of standard quality conforming to IS). The compression fittings for MDPE pipes conforming to ISO 14236 and its latest versions. If the connection is of HDPE pipe the work include electric fusion tapping T or saddles,PE 100 black color pipie of PN 16 /SDR 11 or Higher grade conforming to standards with brass cutter,flow regurator,water tight cap with O’ring ,long spigot for making bore/tapping suitable to HDPE pipe by Electro fusion welding as per BS EN 12201-3 & EN 1555-3 standards. The Product should be tested to comply with BS 6920 for CC1:3:6 wherever required and the stone slab covering should be refixed in position with pointing in CM 1:3 and also the bored wall of the premises should be re-done to the original position and the rates are inclusive of the cost of all the materials, cement, sand water etc., required for these works. The road suface should be compacted well and brought to the original condition and the excess earth or debris shouldCOMMON SCHEDULE OF RATES 71 2021-22 NOSOR CODE DESCRIPTIONS UNIT RATEbe disposed off to a distance with an initial lead of 10 Kms. etc. complete for The excavated trench should be refilled Saddle should be manufactured Virgin Compounded PE 100 material.Tapping Tee or Saddles with coupler and compression fittings with cost of GI pipes, all specials such as GI tee, GI elbow, GI coupler, stopper with appurtenances, and brass or SS tap The excavated trench should be refilled with soft selected earth and the dismantled masonry of the drain should be re-constructed with available size stones in CM 1:8 and providing coping in with soft selected earth drinking water service in WRC - NSF, UK and DVGW certificate, Gemany. The and the dismantled masonry of the drain should be re-constructed with available size stones in CM 1:8 and providing coping in CC 1:3:6 wherever required and the stone slab covering should be refixed in position with pointing in CM 1:3 and also the bored wall of the premises should be re-done to the original position and the rates are inclusive of the cost of all the materials, cement, sand water etc., required for these works. The road suface should be compacted well and brought to the original condition and the excess earth or debris should be disposed off to a distance with an initial lead of 10 Kms. etc. complete for following diameters: (for minimum length of 2m) For 25mm dia (BWSSB SR-2021-2022, P.No-71, I-23.2)

172

-

1130026.24

... More
Supplying and fixing Multijet class B inferential type, AMR compatible water meters with IP 68 protection totalizer confoming to IS 779 with its latest amendments of following size to service connections including conveying and fixing of necessary G.I. specials with appurtenances. complete, with all lead and lift.25mm dia (BWSSB SR-2021-2022, P.No-79, I-54.2)

172

-

509532.8

... More
Sinking Circular wells as per approved design in all kinds of soils excluding hard rock requiring blasting including making and removing islands, ring bunds or coffer dams as may be necessary and maintaining the same during operation, pumping dewatering, application of kentledge or other means for around seating of wells, removal of boulders, burried timbers as directed with necessary shoring and strutting as per specifications etc.complete (Mysure CIRCLE PWD SR 2018-2019 P 97 No.11.12)

3

-

78223.95

... More
Sinking Circular wells as per approved design in all kinds of soils excluding hard rock requiring blasting including making and removing islands, ring bunds or coffer dams as may be necessary and maintaining the same during operation, pumping dewatering, application of kentledge or other means for around seating of wells, removal of boulders, burried timbers as directed with necessary shoring and strutting as per specifications etc.complete (Mysure CIRCLE PWD SR 2018-2019 P 97 No.11.12)

3

-

87809.4

... More
Sinking Circular wells as per approved design in all kinds of soils excluding hard rock requiring blasting including making and removing islands, ring bunds or coffer dams as may be necessary and maintaining the same during operation, pumping dewatering, application of kentledge or other means for around seating of wells, removal of boulders, burried timbers as directed with necessary shoring and strutting as per specifications etc.complete (Mysure CIRCLE PWD SR 2018-2019 P 97 No.11.12)

3

-

100825.2

... More
Providing and laying in position Reinforced cement concrete for RCC Shafts. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cement mortar 1:3, 12 mm thick, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 340 kgs (6.80 bags)).RCC M25 Design Mix with 20mm aggregate for below ground level. m3 12089 (BWSSB SR-2021-2022, P.No-108, I-4.1)

3.603

-

48783.47

... More
Providing and laying in position Reinforced cement concrete for RCC Shafts. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cement mortar 1:3, 12 mm thick, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 340 kgs (6.80 bags)).RCC M25 Design Mix with 20mm aggregate for below ground level. m3 12089 (BWSSB SR-2021-2022, P.No-108, I-4.1)

35.031

-

474308.53

... More
Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cut ting, bending, placing inposition, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (PWD SR-2021-2022, P.No-84, I-11.32)

1150

-

136528

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (PWD SR-2021-2022, P.No-84, I-11.34(A))

250

-

44520

... More
Wire Mesh 50 x 50mm (HASSAN CIRCLE PWD SR 2018-2019/P.No.XXVIII/719)

12.56

-

3692.64

... More
Providing and Fixing 'Maintenance Information Board "Providing and fixing of typical Maintenance information board as per specifications and drawing. ACP Sheet of 3 mm thick having minimum 0.25mm thick aluminum skin both sides and fixed over a back support of Ms plate of 5mm thick. Supported on frame post of 2 no's of MS Suare hallow section 75mmx75mmx6mm which is duly embedded in cement concrete M20 Grade of 600x600x750mm,600mm below ground level.All MS will be stove enameled on both the sides.All sections of framed posts,MS sheet and Stell tubes will be painted with primer and two coats of epoxy paint as per drawing etc..Retro-Reflective Sheet as per IRC 67 fixted over a Aluminum composite material(ACP) sheeting of size 900x1500mm of 3mm thick duly bolted/reveted with MS plate of 5mm thick on backside of ACP Sheet.Including cost and conveyance of all materials,equipment,machinery and labour with all leads and lifts,loading charges charges necessary for satisfactory completion of work as per directed by engineer incharge. (i) For warranty and durability the clause 1701.5 and for maintenance the clause 1911 shall be applicable. (ii) A reference number along with the month and year of installation should be placed on the back of a sign in a contrasting colour or by stamping in characters not exceeding 50 mm in height.485777/2019/Dir(Tech) 7 A Retro Reflective Trafic Sign As per IRC 67 Clause 1701.3.8.1 Class A Type-1 (PWD SR-2021-2022, P.No-141, I-20.35(a))

1

-

22245.44

... More
Cutting Cement Concrete Road surface by Machine cutting to demarcate the trench width of the surface. SOR Code A105C (BWSSB SR-2021-2022, P.No-63, I-1.3)

1.35

-

1437.91

... More
Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. (PWD SR-2021-2022, P.No-5, I No: 1.4)

810

-

168739.2

... More
Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. SOR Code A105CNote: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 :K010A HDPE Grade PE80-PN6.0, 63 mm dia (BWSSB SR-2021-2022, P.No-121, I-1.1)

2000

-

429220

... More
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications (PWD SR-2021-2022, P.No-7 -1.10)

675

-

92232

... More
Wet Mix Macadam (Plant mix method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with Grader in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. Laying Using Grader Ref MORTH 406-B (PWD SR-2021-2022, P.No-29, I-4.14-B)

0.9

-

2413.15

... More
Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14- days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. (SR-2021-2022, P.No-138, I-20.29)

1.35

-

10337.54

... More
CIPET TEST, Dimensions

1

-

500

... More
CIPET TEST Melt flow rate at 190 C/5 Kg

1

-

1100

... More
CIPET TEST Density

1

-

1125

... More
CIPET TEST Reversion Test

1

-

1000

... More
CIPET TEST Elongation at Break

1

-

1100

... More
CIPET TEST Carbon black content

1

-

925

... More
CIPET TEST Carbon Black dispersion

1

-

700

... More
CIPET TEST Oxidation Induction Time

1

-

2200

... More
CIPET TEST Internal Pressure Creep rupturetest of pipe for 48 hoursat 80 degree celsius

1

-

1600

... More
Providing house connection with excavation in all types of soils cutting with machine cutter without damaging the other utilities and supplying and laying of MDPE pipe (PE80) -PN 12.5 manufactured in accordance with ISO 4427 - 1996 with minimum required strength of 8 Mpa, hydraulic design stress of 6.3 Mpa and with minimum wall thickness of 2.3mm /GI pipe by making the bore of 15mm dia. size on the distribution mains using drilling bits or machines only and laying the pipe line at a depth not less than 0.45 mtrs. from the road surface, including providing 40mm dia. “A” class GI pipe as casing over the MDPE pipe from the bore point and upto the entrance of the premises and removing the stone slab covering of the drain and dismantling the size stone masonry wherever necessary and making bore in the wall of the premises. On entering the premises, connection should be continued with 20mm GI pipe by making “U” shape for the meter point below the ground level by making pit with sufficient space for the easy installation and removal of the water meter and providing vertical stand pipes on both sides of the meter. The connection should be secured firmly on thedistribution main pipe with SS / Brass ferrule of size 1/2” x 3/4” and fixing the union joint and gate valve / stop cock before the meter point and a reflex valve / non-return valve should be fixed on the connection after the meter point. (All these fixtures should be of standard quality conforming to IS). The compression fittings for MDPE pipes conforming to ISO 14236 and its latest versions. If the connection is of HDPE pipe the work include electric fusion tapping T or saddles,PE 100 black color pipie of PN 16 /SDR 11 or Higher grade conforming to standards with brass cutter,flow regurator,water tight cap with O’ring ,long spigot for making bore/tapping suitable to HDPE pipe by Electro fusion welding as per BS EN 12201-3 & EN 1555-3 standards. The Product should be tested to comply with BS 6920 for CC1:3:6 wherever required and the stone slab covering should be refixed in position with pointing in CM 1:3 and also the bored wall of the premises should be re-done to the original position and the rates are inclusive of the cost of all the materials, cement, sand water etc., required for these works. The road suface should be compacted well and brought to the original condition and the excess earth or debris shouldCOMMON SCHEDULE OF RATES 71 2021-22 NOSOR CODE DESCRIPTIONS UNIT RATEbe disposed off to a distance with an initial lead of 10 Kms. etc. complete for The excavated trench should be refilled Saddle should be manufactured Virgin Compounded PE 100 material.Tapping Tee or Saddles with coupler and compression fittings with cost of GI pipes, all specials such as GI tee, GI elbow, GI coupler, stopper with appurtenances, and brass or SS tap The excavated trench should be refilled with soft selected earth and the dismantled masonry of the drain should be re-constructed with available size stones in CM 1:8 and providing coping in with soft selected earth drinking water service in WRC - NSF, UK and DVGW certificate, Gemany. The and the dismantled masonry of the drain should be re-constructed with available size stones in CM 1:8 and providing coping in CC 1:3:6 wherever required and the stone slab covering should be refixed in position with pointing in CM 1:3 and also the bored wall of the premises should be re-done to the original position and the rates are inclusive of the cost of all the materials, cement, sand water etc., required for these works. The road suface should be compacted well and brought to the original condition and the excess earth or debris should be disposed off to a distance with an initial lead of 10 Kms. etc. complete for following diameters: (for minimum length of 2m) For 25mm dia (BWSSB SR-2021-2022, P.No-71, I-23.2)

92

-

604432.64

... More
Supplying and fixing Multijet class B inferential type, AMR compatible water meters with IP 68 protection totalizer confoming to IS 779 with its latest amendments of following size to service connections including conveying and fixing of necessary G.I. specials with appurtenances. complete, with all lead and lift.25mm dia (BWSSB SR-2021-2022, P.No-79, I-54.2)

92

-

272540.8

... More
Earth work excavation by manual means for drains,canals and similar works in all kinds of soils , as per drawing and technical specifications, including setting out,shoring, strutting, barricading, caution lights, re moval of stumps and other deleterious matter, excavated surface lev eled and sides neatly dressed disposing off the excavated stuff or sort ing & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work In all kinds of soils Depth upto 1.5 m (PWD SR-2021-2022, P.No-57, I-1.4.1)

24.06

-

5012.18

... More
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD SR-2021-2022, P.No-15, I-2.1.3)

8.46

-

54501.35

... More
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR-2021-2022, P.No-15, I-2.1.3)

28.81

-

185600.93

... More
Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cut ting, bending, placing inposition, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (PWD SR-2021-2022, P.No-84, I-11.32)

528

-

62684.16

... More
Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR-2021-2022, P.No-49, I-8.49)

18480

-

62092.8



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.