Rural Water Supply And Sanitation Department Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Rural Water Supply And Sanitation Department - RWSS Tender

Civil And Construction
Water Storage And Supply
Opening Date13 Jul 2022
Closing Date21 Jul 2022
Tender Amount₹ 59,74,660 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. SOR Code A105CNote: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 :K010A HDPE Grade PE100-PN6.0, 63 mm dia (CSR-2021-2022, P.No-126, I-10.1)

1569

-

296697.9

... More
Refilling available earth around trenches/pipelines , cables in layers not exceeding 20cm in depth, compacting each deposited layer by ramming after watering witha lead up to 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specification(PWD SR-2021-2022, P.No-7, I-1.10)

285.95

-

39072.21

... More
Cable Duct Across the RoadProviding and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction),xtending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings. (CSR 2021-22, P.No 61, I.No 8.29 (i))

32

-

72289.28

... More
Wet Mix Macadam (Plant mix method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with Grader in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. Laying Using Grader Ref MORTH 406-B (PWD SR-2021-2022, P.No-29, I-4.14-B)

2.16

-

4894.04

... More
Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14- days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. (SR-2021-2022, P.No-138, I-20.29)

2.16

-

16540.07

... More
Supply and delivery of Resilient seated soft sealing Sluice Valves with body, bonnet of Ductile Iron of grade GGG50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face dimensions as per BS 5163-89/IS 14846-2000/ DIN 3202 F4/F5. The stem sealing should be with Toroidal sealing rings (minimum 2 'O' rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The valves shall be supplied with suitable size galvanized bolts and nuts of required numbers as per relevant IS. (BWSSB SR-2021-2022, P.No-71, I-25.2,25.3)

11

-

109155.2

... More
Providing 80 mm dia Air Valve confirming to IS 1538 (Part-I to XXII) 1978 with latest amendments if any (RDW&S SR 2019-20 Chapter no : 1, item No : 15.60)

8

-

24192

... More
Supply and delivery of Woltman model with removal mechanism water meters confirming to ISO 4064 part I,II,III class B or IS 779 and IS 2373 with life cycle test certificate from FCRI/ NABL accredited lab. The water meters shall have magnetic drivers or mechanical drivers and shall be versatile for installation in any position. The meters shall be hydro- dynamically, hydrostatically balanced. The runner, runner chamber, pointer of the meter shall be as per ISO 4064 class B specification. Dry dial excavated counter housing fully protected against flooding ensuring easy reading in all climates.(RDW&S SR Myosre Circule P.no:205, Item No: 15.40.2)

1

-

15962.24

... More
Valve ChambersSupplying and fixing of fixed height surface box H-4057 MD-KU with PP 40%GF Lid, Housing of PA+, Locking clip of PP with Notched bolt M 12 x 130 hexagon head A2-70 for service connection valves, design derived from DIN 4057, Should be suppied with support tile I (FSL, FSS ,SI) ,Should be able to receive class AA traffic loads (KUWS&DB SR 2018-19,P.No.23 Item No.20)

12

-

36758.4

... More
CIPET charges for HDPE pipes

4

-

41000

... More
Providing house connection with excavation in all types of soils cutting with machine cutter without damaging the other utilities and supplying and laying of MDPE pipe (PE80) -PN 12.5 manufactured in accordance with ISO 4427 - 1996 with minimum required strength of 8 Mpa, hydraulic design stress of 6.3 Mpa and with minimum wall thickness of 2.3mm /GI pipe by making the bore of 15mm dia. size on the distribution mains using drilling bits or machines only and laying the pipe line at a depth not less than 0.45 mtrs. from the road surface, including providing 40mm dia. “A” class GI pipe as casing over the MDPE pipe from the bore point and upto the entrance of the premises and removing the stone slab covering of the drain and dismantling the size stone masonry wherever necessary and making bore in the wall of the premises. On entering the premises, connection should be continued with 20mm GI pipe by making “U” shape for the meter point below the ground level by making pit with sufficient space for the easy installation and removal of the water meter and providing vertical stand pipes on both sides of the meter. The connection should be secured firmly on thedistribution main pipe with SS / Brass ferrule of size 1/2” x 3/4” and fixing the union joint and gate valve / stop cock before the meter point and a reflex valve / non-return valve should be fixed on the connection after the meter point. (All these fixtures should be of standard quality conforming to IS). The compression fittings for MDPE pipes conforming to ISO 14236 and its latest versions. If the connection is of HDPE pipe the work include electric fusion tapping T or saddles,PE 100 black color pipie of PN 16 /SDR 11 or Higher grade conforming to standards with brass cutter,flow regurator,water tight cap with O’ring ,long spigot for making bore/tapping suitable to HDPE pipe by Electro fusion welding as per BS EN 12201-3 & EN 1555-3 standards. The Product should be tested to comply with BS 6920 for CC1:3:6 wherever required and the stone slab covering should be refixed in position with pointing in CM 1:3 and also the bored wall of the premises

129

-

847519.68

... More
23.4 B070D For connection pipe length beyond 2.0 mtrs for every 1 mtr. or part

52

-

47290.88

... More
Supplying and fixing Multijet class B inferential type, AMR compatible water meters with IP 68 protection totalizer confoming to IS 779 with its latest amendments of following size to service connections including conveying and fixing of necessary G.I. specials with appurtenances. complete, with all lead and lift.25mm dia (BWSSB SR-2021-2022, P.No-79, I-54.2)

129

-

382149.6

... More
Supply and fixing of HDPE water meter box with locking arrangement to protect the water meter of Class ‘B’ Multijet type of size 15 to 32 mm including HDPE box with base dia 300mm x lid dia 200mm x height 250mm with openable lid and the cover is buried below GL with lid flush with GL including earth work excavation for 600mm x 600mm and base sand filling for 100mm thick over which the cover is placed and enclosed by PCC 1:2:4 using 12-20mm BG jelly for an height of 150mm and refilling with excavated earth for balance 100mm height, disposal of excess earth with all lead and lifts with appurtenances complete as per drawing enclosed. (BWSSB SR-2021-2022, P.No-133, I-23)

129

-

73540.32

... More
Earth work excavation by manual means for drains,canals and similar works in all kinds of soils , as per drawing and technical specifications, including setting out,shoring, strutting, barricading, caution lights, re moval of stumps and other deleterious matter, excavated surface lev eled and sides neatly dressed disposing off the excavated stuff or sort ing & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work In all kinds of soils Depth upto 1.5 m (PWD SR-2021-2022, P.No-57, I-1.4.1)

5.8

-

1208.26

... More
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)2.1.3 Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates (PWD SR-2021-2022, P.No-67, I-2.1.3)

3.87

-

24931.47

... More
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates (PWD SR-2021-2022, P.No-69, I-2.4.2)

8.51

-

61085.46

... More
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates (PWD SR-2021-2022, P.No-69, I-2.4.2)for centring, shuttering, strutting, propping etc 5%

0.85

-

6101.37

... More
Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cut ting, bending, placing inposition, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (PWD SR-2021-2022, P.No-84, I-11.32)

1935

-

229723.2

... More
Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR-2021-2022, P.No-49, I-8.49)

1935

-

6501.6

... More
Providing and Fixing 'Logo' of PMGSY ProjectProviding and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. i)The board will be a composite unit consisting of three plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most platewill be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges. The middle plate will be 1200 mm x 150 mm size riveted over welded M.S. angle iron frame of 25mm x 25mmx 5 mm size on back on edges. The main lower most plate will be 1500 mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25 mm x 5 mm size. Welding of all the sheets over angle iron frame will be done neatly to have plain surface on one side. The angle iron frames of the lower most plate and the middle plate will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1125 mm apart centre to centre. The top of the middle plate will be flushed with the top of 75 mm tube posts and these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The height of bottom of the lower most plate will be 1200 mm from normal ground level and the bottom of middle plate will be 100 mm above the top level of the lower most plate. The diamond shaped plate mounted over angle iron frame will be connecte to middleplate by square medium steel section of 47 mm x 47 mm thickness 12 SWG having a spacing of 100 mm between the diamond shaped plate and middle plate and this square section will be welded to the bottom point of the diamond shaped plate.(ii) The lettering and borders, etc. of middle and bottom plate, PMGSY logo on top plate shall be as per clause 1701.4.6 essages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing.(iii) For warranty and durability the clause 1701.5 and for maintenance the clause 1911 shall be applicable.(iv) A reference number along with the month and year of installation should be placed on the back of a sign in a contrasting colour or by stamping in characters not exceeding 50 mm in height.485777/2019/Dir(Tech) 7B Retro Reflective Trafic Sign As per IRC 67 Clause 1701.3.8.2 Class B Type-3 (PWD SR-2021-2022, P.No-139, I-20.30(B))

1

-

19600

... More
Earth work excavation for Foundation by manual means for all Buildings, Bridges, Retaining walls, Abutment Piers and such similar works as per drawing and technical Specifications, including setting out, providing shoring & strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces,disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.

4.4

-

916.61

... More
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, plywood / steel formwork, cost of all materials of quality, labour, Usage charges of machineries, curing and all the other appurtenances required to complete the work as per technical specifications. ( The cost of steel reinforcement shall be paid separately).

0.66

-

4244.49

... More
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, strutting, plywood / steel form work , Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) (Minimum cement content: 340 kgs (6.80 bags)).RCC M25 Design Mix with 20mm aggregate

1.16

-

12573.66

... More
Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cut ting, bending, placing inposition, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)

65.65

-

7793.97

... More
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.

1.22

-

9623.56

... More
Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

13.33

-

3777.19

... More
Polyethylene water storage tank of specified capacity and make(WS SR-2019-2020, Sl no 679 item no 0302)

2000

-

10000

... More
Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

72.89

-

8898.41

... More
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m� over an under coat of primer applied @ 0.80 ltr/10 m� of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

3.06

-

363.28

... More
Providing and laying to required line and slope roofing with semicorrugated ( Trafford ) asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers, over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications.

3.57

-

1495.4

... More
Providing, supplying to work site,Single Phase Submersible Pump Setsof 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000specifications,with testing of as per instructions of engineer incharge ofwork and latest amendments. (BWSSB SR 2022-23,, Page 158, Item No. 4)

1

-

26264

... More
Supply and delivery at site Brand new best make PVC insulated cable of Supplying,laying,jointing ,testing and commissioning of G.I.Pipes conforming to IS 1239:1990 with latest amendments,including fixing Collars, Elbows, Tees, bends, Glad Cocks and other Fittings (Excluding Cost of Specials) with Cuts and Threads wherever necessary including conveying the materials to workspot, including testing for water tightness with all lead and lifts etc complete (Contractor shall make his own arrangements for procuring water for testing)( Schedule of rates RWS&SD my sore circle 2019-20 Page no 78 item no.10.04.3 )Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. [P 103 No.12.03] 1x3x4 Sqm

10

-

5185.6

... More
Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x4 m2 (BWSSB SR 2022-23,, Page 161, Item No-22.3)

10

-

1840

... More
Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter (BWSSB SR 2022-23,, Page 162, Item No-29.2)

1

-

10640

... More
Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (BWSSB SR 2022-23,, Page 163, Item No-38

1

-

6888

... More
Fabricating supplying and mounting MS box made out …SWG suitable for floor / wall mounting, fully weather proofwith provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paintt and finally finished with approved colour etc., complete. (Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.5.42)

19500

-

7215

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. (Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.5.41)

2

-

926

... More
Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 (Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.3.1)

1

-

138.6

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.2.3.3) 2.5sqmm

10

-

336

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.2.3.3) 4sqm

15

-

708.75

... More
Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.5.7.2)

1

-

2516.85

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898..(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.5.17.9)

1

-

2940

... More
Fixing a shunt capacitor of … KVAR capacity with necessary clamps, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.14.15.1)

3

-

661.5

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C..(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.5.38)

1

-

451.5

... More
Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (BWSSB SR 2022-23,, Page 164, Item No-45)

1

-

4200

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.6.4.2)

15

-

2047.5

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.6.5.1) 6sqmm to 16 sqmm

10

-

124.7

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.6.5.1) 6sqmm to 16 sqmm

10

-

315

... More
Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.6.6.2)

10

-

1071

... More
Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.6.9.1)

4

-

1407

... More
Supplying and fixing L.T. cast Iron pot heads suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps, bolts, nuts and washers etc. (Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.6.10.1)

1

-

273

... More
Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. (Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.6.18.3

6

-

119.7

... More
Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter. (Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.5.35)

1

-

4982.25

... More
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth upto 3 m (PWD SR-2021-2022, P.No-60, I-1.14.1)

32.45

-

2653.11

... More
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, plywood / steel formwork, cost of all materials of quality, labour, Usage charges of machineries, curing and all the other appurtenances required to complete the work as per technical specifications. ( The cost of steel reinforcement shall be paid separately). (BWSSB SR-2021-2022, P.No-107, I-1.3)

2.08

-

13770.27

... More
Providing and laying in position Reinforced cement concrete for columns, braces and ring beam above ground level. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted NO SOR CODE DESCRIPTIONS UNIT RATE CHAPTER - 8 RCC OVERHEAD TANKS COMMON SCHEDULE OF RATES 108 2021-22 NO SOR CODE DESCRIPTIONS UNIT RATE using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cement mortar 1:3, 12 mm thick, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage chargesn of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags)). RCC M30 Design Mix with 20mm aggregate for level 0m to 6m height. (BWSSB SR-2021-2022, P.No-108, I-3.2)

6.75

-

103806.36

... More
Providing and laying in position Reinforced cement concrete for shell portion, bottom dome / slab and ribs over the staging. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cement mortar 1:3, 12 mm thick and CM plastering 1:3 proportion 20mm thick for inside with an admixture of water proof compound of requisite proportion of approved quality, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage charges of machinery, curing plete the work as per design and technical specifications.(Contractor will make his own arrangements for procuring water for testing). (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags)).M30 Design Mix with 20mm aggregate for level and 6 to 9 m height (BWSSB SR-2021-2022, P.No-109, I-5.2)

4.37

-

99380.79

... More
Providing and laying in position Reinforced cement concrete for side walls of water tank over the staging above the ground level. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cement mortar 1:3, 12 mm thick and CM plastering 1:3 proportion 20mm thick for inside with an admixture of water proof compound of requisite proportion of approved quality, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications.(Contractor will make his own arrangements for procuring water for testing). (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags)).RCC M30 Design Mix with 20mm aggregate for level and upto 6 - 9 m height. (BWSSB SR-2021-2022, P.No-109, I-6.2)

9.78

-

233957.94

... More
Providing and laying in position Reinforced cement concrete for top dome of water tank over the staging above the ground level. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes withplastering and smooth finishing in cement mortar 1:3, 12 mm thick for both inside and outside surface, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags)) RCC M30 Design Mix with 20mm aggregate for level and upto 6-9 m height. (BWSSB SR-2021-2022, P.No-109, I-7.2)

2.22

-

51458.53

... More
Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cut ting, bending, placing inposition, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (PWD SR-2021-2022, P.No-84, I-11.32)

3236.8

-

384272.9

... More
Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle of 65 x 65 x 10mm (BWSSB SR-2021-2022, P.No-111, I-11.2)

12

-

63799.68

... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge

500

-

62160

... More
Ladder inside the container: Providing anodized aluminium ladder using 65mm x 32mm x 3.0mm ‘C’ section for ladder side channel x 25mm dia., flutal pipe for Rungs at 250mm c/c ladder fixed at an angle of 70 degrees to horizontal including necessary 25mm dia., G.I. shutters with necessary G.I. fasteners for bracing the ladders to the Tank walls to prevent buckling of the ladder with necessary (M-15) bed for embedding the ladder bottom complete (RDW&S CIRCLE Mysure SR 2019-20 Pg.No.45 It.No.4.63 )

3.3

-

10738.03

... More
Providing and fixing RCC final and ventilators as per approved design and specifications with form works and protected with wire mesh. The plinth to be of RCC circular pillars and canopy with an ornamental finish at top. The first 22.5 cms height to be covered with RCC panelling as per detailed drawings etc. with all lead and lifts and excluding reinforcement steel. For over head tanks upto 2.5 lakhs capacity. (BWSSB SR-2021-2022, P.No- 111, I-12.1)

1

-

6440

... More
Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. (BWSSB SR-2021-2022, P.No- 111, I-13)

1

-

2364.32

... More
Providing and fixing gauge with iron sheet or enamelled guage plate of 3mm to 4mm thick, 0.23 M width with copper floats indicators and flexible nylone wires, painting figures with approved enamel paint etc. with all lead and lifts, complete for: MS Guage sheet for 2.5 m depth (BWSSB SR-2021-2022, P.No-111, I-14.3)

1

-

6144.32

... More
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (BWSSB SR 2021-2022 Vol-2, P.No-41, I-8.1.1)

193.49

-

47242.52

... More
Providing two coats of water proof cement painting with approved colour and shade over one coat of primer including necessary scaffolding and scrapping of old paint and stain with wire brushes and cleaning of paint stains etc. wherever necessary for old RCC over head tanks with all lead and lifts etc. complete for:Tanks staging above 6 m and upto 9 m (BWSSB SR-2021-2022, P.No-114, I-21.2)

193.49

-

35540.24

... More
Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR-2021-2022, P.No- 49, I-1.8.49)

1600

-

5376

... More
Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-10: For Suilce Valve of PN -10.0 and 80mm (PWD SR-2021-2022- Vol-V, P.No-71, I-25.2)

1

-

8974.56

... More
Supplying, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DIflanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete. (BWSSB SR-2021-2022, P.No-112, I-16.1)

46

-

113601.6

... More
Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete For DI/CI puddle flanges of 80mm dia. (BWSSB SR-2021-2022, P.No-112, I-15.1)

1

-

1709.12

... More
Providing 80 mm dia CI bank flange confirming to IS 1538 (Part-I to XXII) 1978 with latest amendments if any cost of all materials, labour charges etc. complete (RWS SR 2019-20, I-15.55, Pg no.-208)

1

-

210

... More
Providing 80 mm dia Bell mouthed pipes (flanged) confirming to IS 1538 (Part-I to XXII) 1978 with latest amendments if any cost of all materials, labour charges etc. complete. (RWS SR 2019-20, I-15.57, Pg no.-209)

4

-

1344

... More
Providing 80 mm dia Duck foot bend confirming to IS 1538 (Part-I to XXII) 1978 with latest amendments if any cost of all materials, labour charges etc. complete. (RWS SR 2019-20, I-15.58, Pg no.-209)

4

-

1470

... More
Supplying and fixing lightening arrestor with aluminium strip 25mm x 3mm size including finial and grounding, aluminium strip to be embeded in one of the columns in and independent GI conduit of 40mm dia. pipe suitably jointed by collars with all specials with all lead and lifts etc. complete for: For Over Head Tanks upto 9 m staging (BWSSB SR-2021-2022 Vol-V, P.No-113, I-17.2)

1

-

9639

... More
Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (BWSSB SR-2021-2022 Vol-V, P.No-187, I-10)

3

-

12983.04

... More
G.I Barbed Wire Fencing 1.2 m high Providing and fixing 1.2 m high GI barbed wire fencing with 1.8 m RCC posts 150 mm x 150 mm placed every 3 m centre-tocentre founded in M15 grade cement concrete, 0.6 m below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 9 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc. complete as per Clause 1705. (PRED SR-2020-2021, I-10.12)

24

-

12760.08

... More
Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm (Depth upto 1.50m not exceeding 1.5m in width ) trench width as per drawing and technical specifications,including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50m (PWD SR-2021-2022, P.No-63, I-1.19.1)

1225.13

-

201705.4

... More
Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, includ ing setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavat ed surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m in cluding cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m (PWD SR-2021-2022, P.No-59, I-1.7.1)

1225.13

-

509066.02

... More
Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. SOR Code A105C Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 :K010B HDPE Grade PE100-PN6.0, 63 mm dia (CSR-2021-2022, P.No-126, I-10.1), HDPE Grade PE100-PN10.0,63mm dia. (CSR-2021-2022, P.No-127, I-12.1)HDPE Grade PE100-PN6.0, 63 mm dia

6000

-

1134600

... More
Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. SOR Code A105C Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 :K010B HDPE Grade PE100-PN6.0, 63 mm dia (CSR-2021-2022, P.No-126, I-10.1), HDPE Grade PE100-PN10.0,63mm dia. (CSR-2021-2022, P.No-127, I-12.1)HDPE GradeHDPE Grade PE100-PN10.0, 63 mm dia

50

-

12682

... More
Earth work excavation for Foundation by manual means for all Buildings, Bridges, Retaining walls, Abutment Piers and such similar works as per drawing and technical Specifications, including setting out, providing shoring & strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces,disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.

4.4

-

916.61

... More
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, plywood / steel formwork, cost of all materials of quality, labour, Usage charges of machineries, curing and all the other appurtenances required to complete the work as per technical specifications. ( The cost of steel reinforcement shall be paid separately).

0.66

-

4244.49

... More
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, strutting, plywood / steel form work , Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) (Minimum cement content: 340 kgs (6.80 bags)).RCC M25 Design Mix with 20mm aggregate

1.16

-

12573.66

... More
Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cut ting, bending, placing inposition, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)

65.65

-

7793.97

... More
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(PWD SR 2022-23, Item No:6.1 Page 13)

1.22

-

9623.56

... More
Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(PWD SR 2022-23, Item No:8.2.1 Page 41)

13.33

-

3777.19

... More
Polyethylene water storage tank of specified capacity and make(WS SR-2019-2020, Sl no 679 item no 0302)

2000

-

10000

... More
Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

72.89

-

8898.41

... More
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m� over an under coat of primer applied @ 0.80 ltr/10 m� of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD SR 2022-23, Item No:8.33.3 Page 47)

3.06

-

363.28

... More
Providing and laying to required line and slope roofing with semicorrugated ( Trafford ) asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers, over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications.(PWD SR 2022-23, Item No:7.19 Page 23

3.57

-

1495.4

... More
Providing, supplying to work site,Single Phase Submersible Pump Setsof 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000specifications,with testing of as per instructions of engineer incharge ofwork and latest amendments. (BWSSB SR 2022-23,, Page 158, Item No. 4)

1

-

26264

... More
Supply and delivery at site Brand new best make PVC insulated cable of Supplying,laying,jointing ,testing and commissioning of G.I.Pipes conforming to IS 1239:1990 with latest amendments,including fixing Collars, Elbows, Tees, bends, Glad Cocks and other Fittings (Excluding Cost of Specials) with Cuts and Threads wherever necessary including conveying the materials to workspot, including testing for water tightness with all lead and lifts etc complete (Contractor shall make his own arrangements for procuring water for testing)( Schedule of rates RWS&SD my sore circle 2019-20 Page no 78 item no.10.04.3 )Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. [P 103 No.12.03] 1x3x4 Sqm

10

-

5185.6

... More
Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x4 m2 (BWSSB SR 2022-23,, Page 161, Item No-22.3)

10

-

1848

... More
Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter (BWSSB SR 2022-23,, Page 162, Item No-29.2)

1

-

10640

... More
Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (BWSSB SR 2022-23,, Page 163, Item No-38)

1

-

6888

... More
Fabricating supplying and mounting MS box made out …SWG suitable for floor / wall mounting, fully weather proofwith provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paintt and finally finished with approved colour etc., complete. (Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.5.42)

19500

-

7215

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. (Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.5.41)

2

-

966

... More
Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 (Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.3.1)

1

-

138.6

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.2.3.3)2.5 sqmm

10

-

336

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.2.3.3)4

15

-

708.75

... More
Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.5.7.2)

3

-

548.1

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898..(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.5.17.9)50-63Amps TPN

1

-

2516.85

... More
Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board.(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.5.20.3)

1

-

2940

... More
Fixing a shunt capacitor of … KVAR capacity with necessary clamps, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.14.15.1)

3

-

661.5

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C..(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.5.38)

1

-

451.5

... More
Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (BWSSB SR 2022-23,, Page 164, Item No-45)

1

-

4200

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.6.4.2)

15

-

2047.5

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.6.5.1) 6 sqmm to 16 sqmm

10

-

124.7

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.6.5.1) 6 sqmm to 16 sqmm

10

-

315

... More
Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.6.6.2)

10

-

1071

... More
Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.(Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.6.9.1) 40mm

4

-

1407

... More
Supplying and fixing L.T. cast Iron pot heads suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps, bolts, nuts and washers etc. (Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.6.10.1)

1

-

273

... More
Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. (Schedule of Rates PWD,Electrical SR 2019-20

6

-

119.7

... More
Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter. (Schedule of Rates PWD,Electrical SR 2019-20 ITEAM No.5.35)

1

-

4982.25



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.