The BTDA has issued a formal invitation for competitive bids for the Bagalkot Town Development Authority project, for Construction Of 110kv Dc Line From Existing 220kv Bagalkot S/s - 110kv Bagalkot S/s , Dc Line To Proposed 110kv Navanagar Unit-2, Sub-station -2, Between Location No-365 To 366 By Terminating Of Portion Of Existing Line., In Bagalkote Taluk And Bagalkote Dist For A Distance Of 1.029kms By Using Nbt Along With One Number Of Tb At Unit-2, Sub Station -2. Under Self Execution Scheme in Bagalkot, Karnataka, with an estimated contract value of Rs. 2,16,77,299. The bid opening date for this tender is 27-12-2022 and the last date for bid submission is 09-01-2023. Interested bidders for Bagalkot Town Development Authority tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Bagalkot Town Development Authority - BTDA Tender

Civil And Construction
Civil Works Others
Electrical and Electronics
Electrical Works
Opening Date27 Dec 2022
Closing Date9 Jan 2023
Tender Amount₹ 2,16,77,299 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Equipment name boards. Earth Pit Name boards.

10

-

10000

... More
Conductor & Earth wire :Lynx ACSR Conductor

6.267

-

37150.78

... More
iii) 4 C x 2.5 Sqmm

200

-

18800

... More
Setting of stub templates and aligning dismantling and transportaion of templates from one location to another location for 110 kV

11

-

6259

... More
Isolators :Isolators including marshalling box and suitable terminal conductor as per technical specification with solid core cylindrical post insulators with live point height 4600 mm. 1)110 KV, 1250 A, 25 KA Class Double Break Manually Operated isolator. a) Upright mounting type with manually operated with earth switch. (live point height 4600mm)

1

-

260000

... More
Construxction of Brick masonary inspection chamber with cast iron cover of size 450 x 450 mm as per technical specification design and drawing

3

-

15900

... More
Testing & Commissioning:-Circuit Breaker :SF6 Gas circuit breaker with Semi-Pneumatic / Pneumatic operated / Spring type operating mechanism, including mounting arrangements, rigid bi-metallic terminal connector complete suitable for Drake ACSR conductor and mounting structures. a) 110kV, 1250A, 31.5KA Class.

1

-

36995

... More
Supply of Galvanised Bolts & Nuts

2.133

-

245295

... More
Conductor & Earth wire :Lynx ACSR Conductor

6.267

-

639234

... More
f) Supplying and fixing 450mm dia x 450mm height 1.5" to 2" Hume pipe collars for earth pits.

5

-

5060

... More
Current Transformer :Current Transformer including Marshalling box single phase, oil filled outdoor type with rigid bi-metallic terminal connectors suitable for Drake ACSR.a) 110 KV Class, 31.5 KA, CT of ratio 400-200/1-1-1A for Lines. Accurecy class 0.2s, 5P20, PS

3

-

11549.01

... More
Towers 110 kV-'NBT DC 'C' Type :C - Normal (2),Stubs for 'C' Type tower(2),'NBT DC 'D' Type :D - Normal (8),9th Cross arm for D Type(5) ,Stubs for 'D' Type tower(8),'DC 'D' Type Convetional AEQUS-D - Normal (1),Stubs for 'D' Type tower(1) -Total-HT portion(11)

3.271

-

297661

... More
v) 2 C x 2.5 Sqmm

100

-

6200

... More
Single Tension string of 8 units each along with hardware for Lynx ACSR and arcing horn

48

-

223935.36

... More
vi) Lightening arrestors 96KV.(1=0.115MT)

3

-

29625

... More
d) G.I.Flat 50 x 6 mm for connecting equipment to earth mat

200

-

45200

... More
Pedestal insulators. 110 kV . (0.1400 MT per tower)

3

-

17700

... More
Dry fissured rock/ soft rock bai blasting (I No:2.5 P.No:5)

1095.01

-

2334013.82

... More
Surge Arrestor : (Porcelain housing) with Metal Oxide Gap less type as per technical specification:i) 96 KV, 10 KA Class - II

3

-

99000

... More
A) Hardwares : a) C type Wedge connector suitable for Drake - Drake (Bus)

3

-

5604

... More
a) Ground wire

1.044

-

60552

... More
Current Transformer :-Current Transformer including Marshalling box single phase, oil filled outdoor type with rigid bi-metallic terminal connectors suitable for Drake ACSR.-a) 110 KV Class, 31.5 KA, CT of ratio 400-200/1-1-1A for Lines. Accurecy class 0.2s, 5P20, PS

3

-

249000

... More
Danger Boards

11

-

594

... More
Control & Relay Panel : Simplex Type Control and Relay Panel complete as per specifications. For 110 KV Transmission line.Note: 1) All the C&R panels and associated panels shall be of one and the same make for uniformity and interchangeability of components, 2) The DLMS protocol energy meter/electronic trivector meter with ABT features has to be provided both on the HV side and LV side of C&R panel, 3) Compitable to SCADA. 4) The line panel with differential numerical relay since line length from 220KV Bagalkot -proposed station is less than 04Kms

1

-

34653

... More
Current transformer. 110 kV & 11 kV NCT's (0.156 MT per tower)

3

-

17700

... More
Supplying and providing of line differential Relays to be similar make ( 87L) at 220KV Bagalkot existing panel. 220KV Bagalkot-02Nos and 110KV Navanagar unit-2 stnII-02Nos

4

-

700000

... More
Miscellaneous items rubber mat 1000x2000mm, 15 KV

1

-

5000

... More
Labour:-Total-HT portion(11)

3.271

-

8763.01

... More
Lightening arrestors. 110 kV . (0.115 MT per tower)

3

-

17700

... More
Tack welding of Bolts and Nuts (No of tower x 270)

2970

-

44550

... More
Repair sleeves suitable for Lynx ACSR

4

-

1564

... More
Station Structures : A) 110KV side station structures fabricated out of galvanised mild steel includingBolts and Nuts ( Approx. unit Wt. in in MT add 5% towards bolt and Nuts ) Note: The 1T1 tower & 1B1 beam shall be suitable for bay width of 10.4Mtrs ii) Station Beam-1B1 - 0.553 MT.

1

-

2715

... More
Vibration dampers for Lynx

132

-

88572

... More
Earth bond 450 mm long

22

-

9094.14

... More
Hardware for Earthwire :-M S C Joints suitable for Ground wire

2

-

606

... More
Single Tension clamps (bolted type) suitable for Ground wire

22

-

17952

... More
P G Clamps suitable for GROUND wire

22

-

5852

... More
F&I at 6% on Material cost

1

-

181519.65

... More
A) BUS BAR Formation a) DRAKE ACSR

150

-

30750

... More
Station Structures : A) 110KV side station structures fabricated out of galvanised mild steel includingBolts and Nuts ( Approx. unit Wt. in in MT add 5% towards bolt and Nuts ) Note: The 1T1 tower & 1B1 beam shall be suitable for bay width of 10.4Mtrs ii) Station Beam-1B1 - 0.553 MT.

1

-

46402

... More
Supplying and fixing Barbed wire

1428

-

72828

... More
Grounding of tower with GI Pipe including the cost of GI pipe

11

-

38775

... More
Single Suspension string of 7 units each.along with hardware for Lynx ACSR and arcing horn

15

-

66761.7

... More
Total : MS portion (11)

69.131

-

5668742

... More
iii) 4 C x 2.5 Sqmm

200

-

2200

... More
Copper Control Cables : 1.1kV class PVC insulated Copper Control Cable with Lugs/Ferrules/ glands as per technical specifications. i) 19 C x 2.5 Sqmm

250

-

2750

... More
Wet Black Cotton/ordinory soil (I.No:2.3 P.No:5)

876.008

-

471467.51

... More
ii) 110KV Current Transformer. (1=0.158MT)

3

-

40056

... More
Control & Relay Panel : Simplex Type Control and Relay Panel complete as per specifications. For 110 KV Transmission line.Note: 1) All the C&R panels and associated panels shall be of one and the same make for uniformity and interchangeability of components, 2) The DLMS protocol energy meter/electronic trivector meter with ABT features has to be provided both on the HV side and LV side of C&R panel, 3) Compitable to SCADA. 4) The line panel with differential numerical relay since line length from 220KV Bagalkot -proposed station is less than 04Kms

1

-

441000

... More
Tower accessories : Supplying and fixing GI angle 45x 45x5 mm 1Mtr length with cleats, bolts nuts as per specification and fixing above 0.5 mts length each at inner and outer surface of tower to facilitate running of barbed wire AC device

11

-

30591

... More
Insulators :i)110KV cylindrical solid core as per IS5350, part II & III a. 110KV Class, 1 Unit/stack

3

-

29301.51

... More
Foundation: Engineering supply of all labours, materials and construction of RCC Footings of any depth, pedestals including the cost of Excavation, Concreting, Cement, Reinforcement steel for all the works, Grouting, under pinning etc., for the following station towers/Mounting structures,--110 kV, 1250 A, 40 KA SF6 CB ( 1No-Incoming & 1no Releasing and re-fixing)

1

-

29100

... More
Current Transformer :Current Transformer including Marshalling box single phase, oil filled outdoor type with rigid bi-metallic terminal connectors suitable for Drake ACSR.a) 110 KV Class, 31.5 KA, CT of ratio 400-200/1-1-1A for Lines. Accurecy class 0.2s, 5P20, PS

3

-

6432

... More
ii) 110KV Current Transformer. (1=0.158MT)

3

-

6096

... More
b) Earth wire 7/3.15mm steel with clamps/lugs

50

-

2900

... More
Control & Relay Panel : Simplex Type Control and Relay Panel complete as per specifications. For 110 KV Transmission line.Note: 1) All the C&R panels and associated panels shall be of one and the same make for uniformity and interchangeability of components, 2) The DLMS protocol energy meter/electronic trivector meter with ABT features has to be provided both on the HV side and LV side of C&R panel, 3) Compitable to SCADA. 4) The line panel with differential numerical relay since line length from 220KV Bagalkot -proposed station is less than 04Kms

1

-

4005

... More
a) Ground wire

1.044

-

5743.04

... More
b) ADSS communication Cable with all accessories ( from 220KV Bagalkot-Proposed Unit-2, Stn-2)

4

-

22004

... More
F&I at 6% on Material cost

1

-

527763.79

... More
Number Plates

11

-

594

... More
Accessories for Conductor : M S C Joints suitable for Lynx ACSR

5

-

2210

... More
ii) 4 C x 6.0 Sqmm

350

-

3850

... More
Grounding of tower with GI Pipe including the cost of GI pipe

11

-

15675

... More
Double Tension string of 8 units each along with hardware for Lynx ACSR and arcing horn

84

-

861053.76

... More
Labour:-Total : MS portion (11)

69.131

-

185201.95

... More
G I MOUNTING STRUCTURES: i) 110KV Isolators 4600 LPH (1=0.752MT)

2

-

4064

... More
Steel Reinforcement

23363.64

-

1806943.92

... More
vi) Lightening arrestors 96KV.(1=0.115MT)

3

-

6096

... More
Insulators :i)110KV cylindrical solid core as per IS5350, part II & III a. 110KV Class, 1 Unit/stack

3

-

777

... More
v) 2 C x 2.5 Sqmm

100

-

1100

... More
a) Upright mounting type with manually operated with earth switch. (live point height 4600mm)

1

-

6430

... More
Circuit plates

22

-

3317.38

... More
v) 110KV Bus pedestal insulators (1=0.140MT)

3

-

35727

... More
Check survey using ther own equipment for 110 kV Plain terrain

1.029

-

2263.8

... More
b) 1.1kv pvc insulated 25 Sq,mm Al,cable 4 core with glands/lugs/ferrules.

50

-

6550

... More
Foundation Concreting :-Reinforced Cement Concreting and curing 1:3:6

35.04

-

284507.28

... More
Civil portion-Excavation for foundation including Back filling, levelling of consolidation.(only labour) :Normal/hard soil (I No:2.4 P.No:5)

219.002

-

147497.85

... More
Number Plates

11

-

1658.69

... More
b) Upright mounting type with manually operated without earth switch. (live point height 4600mm)

1

-

781

... More
Material:-Circuit Breaker :SF6 Gas circuit breaker with Semi-Pneumatic / Pneumatic operated / Spring type operating mechanism, including mounting arrangements, rigid bi-metallic terminal connector complete suitable for Drake ACSR conductor and mounting structures. a) 110kV, 1250A, 31.5KA Class.

1

-

486000

... More
Copper Control Cables : 1.1kV class PVC insulated Copper Control Cable with Lugs/Ferrules/ glands as per technical specifications. i) 19 C x 2.5 Sqmm

250

-

86750

... More
Back filling and levelling with available soil (I.No: 2.10 P.No:6)

1806.43

-

399401.67

... More
v) 110KV Bus pedestal insulators (1=0.140MT)

3

-

6096

... More
b) Upright mounting type with manually operated without earth switch. (live point height 4600mm)

1

-

6430

... More
iv) 2 C x 6 Sqmm

150

-

1650

... More
G I MOUNTING STRUCTURES: i) 110KV Isolators 4600 LPH (1=0.752MT)

2

-

125044

... More
ii) 4 C x 6.0 Sqmm

350

-

57050

... More
110 kV Isolators.

2

-

27800

... More
iv) 2 C x 6 Sqmm

150

-

15300

... More
Danger Boards

11

-

1844.59

... More
b) C type Wedge connector suitable for Lynx - Drake (Line)

3

-

4668

... More
P G Clamps suitable for Lynx ACSR

132

-

67716

... More
Repair sleeves suitable for Ground wire

2

-

408

... More
b) Upright mounting type with manually operated without earth switch. (live point height 4600mm)

1

-

222000

... More
b) ADSS communication Cable with all accessories ( from 220KV Bagalkot-Proposed Unit-2, Stn-2)

4

-

380000

... More
Cable ducts :Cable ducts : Construction of RCC Main Cable duct type SSY-IV with 1 nos of NP2 Pipe with internal dimension 450 x 450 mm as per Technical specification design and drawings. including material, cement, steel, flats.

20

-

10860

... More
Plain Cement Concreting and curing M20

291.37

-

2495147

... More
Circuit plates

22

-

1188

... More
Labour:-Circuit Breaker :SF6 Gas circuit breaker with Semi-Pneumatic / Pneumatic operated / Spring type operating mechanism, including mounting arrangements, rigid bi-metallic terminal connector complete suitable for Drake ACSR conductor and mounting structures. a) 110kV, 1250A, 31.5KA Class.

1

-

12939

... More
a) Upright mounting type with manually operated with earth switch. (live point height 4600mm)

1

-

781

... More
LT power armoured Cable a)1.1kv pvc insulated 95 Sq,mm Al,cable 4 core with glands/lugs/ferrules.

25

-

12600

... More
e) Providing C.I. Pipe of 100mm ID 13mm thick 2.75 Mtrssss. long with 2 part GI Flat 50x6mm clamp welded allround the pipe etc., including cost of excavation (all materials supplied by contractor)

5

-

54940

... More
Phase plate (Set of 3 No.)

22

-

8750.94



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.