Patliputra Medical College And Hospital Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Patliputra Medical College And Hospital Tender

Goods
Eprocure
Opening Date16 Nov 2020
Closing Date2 Dec 2020
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Height Measurement Scale Floor Model Height Measuring Scale. Measuring range : 20-205cm

1

-

-

... More
Weighing Machine Capacity: 2-150 Kg (unit: Kg Lb St) Graduation: D = 100 g LCD display: 78 x 36 mm Vibration boot of automatic zero tracking, automatic power off Overload indication Low power indication Power: 2 x 3 v CR2032 lithium battery.

1

-

-

... More
Radio frequency ablation machine Should have automatic and independent control of up to four electrodes at once. Create up to two bipolar RF lesions at once. Can be controlled using a wireless hand controller. Should be fully operable using 12 inch touch screen. Should displays individual RF readings for all four electrodes. Thermal and Pulsed RF treatment on 1, 2, 3, or 4 electrodes. Bipolar RF on 1 or 2 pairs of electrodes. Independent electrode control with automatic stagger start feature. Personal settings pre-sets for multiple physicians and procedures. Facility for electronic procedure records and screen shots.

1

-

-

... More
FLUOROSCOPY MACHINE (C-ARM) IMAGE INTENSIFIFER: HIGH FREQUENCY C-ARM 9”. Image Intensifying Tube 9 inches Normal = 9”, Zoom1 = 6”, Zoom2 = 4.5”.CCD Camera High resolution camera Monitor One no.32”HD LED Monitor along with a trolley. C-ARM MOBILE FRAME Rotation 180 degrees. Motorized Up/Down 430 mm Horizontal Travel 200 mm Arc Orbital Movement 120 degrees. Wig Wag ±12.5 degrees. HIGH FREQUENCY X-RAY GENERATOR Tube Head and generator 40 KHz. stationary anode tube Max. Voltage 100 KV Fluoroscopic mA 0.1- 4.5mA (normal mode) Mains Voltage 230V AC ± 10%, 50 Hz.Max. output power 3.5 KW (Stationary Tube) PARAMETER SELECTIONS Display Fumigation friendly laminated LED water resistance display Technic Selection Fluoro Fluoroscopic Timer Five minutes cumulative timer with buzzer. Fluoro mA Continuously variable. Temp. Sensor. Automatic cut off provided. Power supply Single phase 230 V, ± 10% AC, 50 Hz Automatic Brightness Control Provided to operate the equipment in automatic mode for hands free operation. Digital image memory systems: Digital HD Memory 100 frames and expendable on Pen Drive with: 1. Feature of LIVE and PULSE Fluoroscopy 2. Averaging of Frames 1 to 16 frame 3. Permanent storage up to 100 frame 4. Negative image 5. Image rotation 6. Pen drive for additional image storage.

1

-

-

... More
ULTRASOUND MACHINE FOR REGIONAL ANAESTHESIA  Ultrasound system should be suitable for use in point of care Ultrasound guided regional anaesthesia (PNB, neuraxial applications) & Ultrasound guided vascular access (PICC, PVC, arterial access)  It should have fully digital portable point of care ultrasound system with provision for Doppler examinations.  Ultrasound system should have one touch scanning 6 preset settings for Superficial Nerves {0-4cm}Medium Nerves {4-6cm} Vascular Access Lung Scan Deep Nerves {+6cm} FAST Scan  Ultrasound system should be light weight.  Ultrasound system must have monitor dimension 13 - 17 inches flat panel with integrated touch screen display for finger gesture interface and pan in zoom feature.  Minimum grey scale resolution to be 256 in 2D mode with upto 1024 scan lines, depending on transducer and imaging mode.  Ultrasound system should have transducer with detachable cable and provision of minimum 2 transducers. System should be supplied with two Transducers (one each as below): 1) Linear transducer(L12-4) : 12 to 4 MHz for shallow applications, vessel imaging 2) Convex (C5-2 broadband curved array transducer ) : 5 to 2 MHz with 50mm radius of curvature for deeper applications  Ultrasound system should be upgradable to ultrasound based Needle Tip Tracking technology for nerve blocks.  Ultrasound system should support imaging modes of M Mode, Colour Doppler, Colour Power Angio and 2D –Mode along with 2D -SonoCT real-time compound imaging , 2D-XRES Adaptive Image Processing, 2D-Tissue Harmonic Imaging technologies to drastically reduce speckle noise and noise artifacts. Ultrasound system should have technology to provide 3 angle settings to comply to the needle trajectory angle for optimized visualization of needle. Ultrasound system should have atleast 75 to 80 frames per second in high frame rate mode.  Ultrasound system should have imaging provision of Auto scan, zoom magnification, Cineloop review. The system must have HDMI, speakers, 5 USB ports, Ethernet, WIFI connection, DICOM, MWL remote services . The system must be equipped with full suite of connectivity features to support built in WIFI for DICOM data transfer to hospital and cloud PACS, to easily share and store images.  Unit should function with System on AC power: 100-240 V~, 50 Hz or 60 Hz, and can be used for scanning for up to 3 hours on a new, fully charged replaceable lithium battery. Ultrasound system should be USFDA Certified .  Warranty: The unit, transducers and all accessories should be covered with warranty for 3 years.

1

-

-

... More
Patients controlled analgesia system (Portable)  Flow rate range 0.01 - 999.9ml/h o 0.01-99.99ml/hinincrementsof0.01ml/h o 100.0-999.9ml/hinincrementsof0.1ml/h  Syringe sizes :- 2/3; 5; 10; 20; 30; 50/50ml  Online rate modification without deliveryinterruption  Accuracyofsetdeliveryrateequalorlessthantyp.+/-2 %  Bolusapplication Delivery rate 1 – 1,800 ml/h; max. Bolus Volume 99.99ml  Bolus ondemand  Bolus with volume/dosepre-selection  Bolus over time (1 min - 24h) cclusion Pressure: 75 mmhg to 900 mmhg  KVOrate  Rate = 10 ml/h: KVO rate 3ml/h  Rate 10 ml/h: KVO rate 1ml/h  Rate 1 ml/h: KVO rate = setrate  User individual configuration or deactivation of KVO rates possible.  Drug library :- 750 drugs including all parameters in drug library Up to 10 user defined drug categories  Medication error prevention through dose limits referring to selecteddrug  Automated syringe change for optimal start upcharacteristics  Standardized User Interface for all Syringe & volumetricinfusion pumps. Optional upgrade of pumps to special therapy like TCI, PCA of thesame  Integrated docking system with central alarm and runningindication Dose calculation- Automatic calculation of the delivery rate based on dose entries in mg, µg, IE or mmol, weight- and/or time related (e.g. mg per kg/min; mg/kg/h; mg/kg/24h, bolus application in mg, µg, IE, mmol per kg and/or per time unit (min) with automatic calculation of the bolus rate for one bolus infusion.Key pad: - Clearly structured, back lit key pad with not more than 8 keys for fast and intuitive operation; identical to Infusion pump SafetyFeatures:- Free flow-protection: - Integrated piston brake within syringe drive to prevent free flow dring Syringe change.Occlusionalarmpressurelimits:-Adjustablein9steps(0.1-1.2barorDisplayinmmHg) Datalock:- Adjustablein2safetylevels(parametersanddisposables) Automatic bolus reduction after occlusion alarm Power Supply:- Main Powersupply:- Mains adaptor (rated voltage 100…240 V AC, 50/60 Hz) for standalone operation. Externallowvoltage 11 … 15 V; via external power supply 12 V or via central power Station Batterytype:- Rechargeable NiMH battery pack, quick and easy exchange without using screw-driver to open thepump. Battery operating time approx. 14 h at 20 ml/h with Battery capacity display in h and min. PCA Pump should be USFDA & CE Certified.

1

-

-

... More
Epidural set

1

-

-

... More
Central Venous Line Catheter Double Lumen 7fr-15cm/20cm

1

-

-

... More
Central Venous Line Catheter triple lumen

1

-

-

... More
Anaesthesia Machine (advance work station) Modular, three gas Anaesthesia workstation with an integrated ventilator for adult to infants and integrated airway pressures and volume. The machine should be suitable for low and minimal flow anaesthesia application with compliance compensation of breathing circuit, fresh gas flow compensation/decoupling. Should have Automatic system test. Should have precise digital fresh gas setting of Air, N2O and O2 with a total fresh gas flow meter for indication. The anaesthesia machine, inbuilt ventilator, vaporizer and patient monitor should be manufactured by same company to maintain uniformity of part and efficient after sale service. The system should have minimum 1 hour battery backup. Should have integrated anaesthesia gas monitoring module with automatic identification of agent with values display on patient monitor including MAC value. System should have US FDA and European CE approved confirms to EN 60601-2-13 (Requirement for safety and essential performance of anaesthesia system). Gas Delivery System: Should have pin index yokes for Oxygen & Nitrous Oxide besides separate connection for central gas supply for Oxygen, Nitrous Oxide and Air. The machine should have pressure gauges for cylinders and central supply lines mounted on front of Anaesthesia machine for better visibility. The gas connections should be non-interchangeable. The system should be suitable to use at minimal flow up to 500ml fresh gas setting. To ensure patient safety minimum Oxygen flow of 200 ml at low fresh setting even below/ total 500 ml fresh gas flow. Automatic cutoff of N2O by Oxygen pressure failure. Hypoxic guard for linear regulation of minimum oxygen concentration at 23% volume. Emergency Oxygen flush at 30-70 L/min bypassing the vaporizer. In the event of complete power loss and battery failure it shall be possible to manually ventilate and deliver anaesthetic agent. Vaporizer: Machine should have possibility to mount two quick-mount type vaporizer, for easy interchangeability and safety with interlock facility. Should be provided with a Temperature/ pressure compensated and flow independent Vaporizer for Halothane or isoflourane or sevoflurane. Vaporizer should have extended delivery range from 0-6 Vol. % The vaporiser should require no calibration in its life time.Should be supplied with Vaporisers for Isoflourane & Sevoflourane. Breathing System: Should have fresh gas de-coupled semi closed circle absorber system. Should have adjustable pressure relief valve from 5 to 75 mbar. Should have change over from Spontaneous to Bag ventilation with single step. The system should have leak and compliance test (including patient hoses up to the Y piece). Should have an external fresh gas outlet for connection Magil’s or Bain’s circuit. Integrated Anaesthesia Ventilator: The system should have electronically controlled inbuilt Ventilator. Should not require changing of bellows for adult and infants. Should have colour TFT screen. Modes: Manual/Spont, Volume controlled, Pressure controlled. The same ventilator should be capable to be upgrade to SIMV with pressure support. Tidal Volume: 20 ~ 1400ml. PEEP: 0 ~ 20 mbar. Breathing Frequency: 4 to 60 BPM. I:E Ratio: 4:1 to 1:4. Inspiratory pause:0-80% of Ti. Should have Desflurane compensation. Integrated Airway monitoring and display of following parameters: Expiratory Tidal Volume, Expiratory Minute volume, PEEP, Peak & Mean and Plateau airway pressure, Frequency, Waveform display for Airway pressure. Adjustable high/low alarm limits with audio and visual alarms for the following: Minute volume, Airway pressure (including stenosis and disconnect), Inspired oxygen concentration, Audio power supply fail alarm, Fail to cycle warning. Machine should have RS 232 connectivity port. The device should have port for anaesthesia gas scavenging system. MONITOR: high resolution 10ʺ or above colour Medical grade screen, modular, should measure parameters for all type patients (Adult, Paediatric & Neonatal):- 12 Lead ECG, SpO2, NIBP, ETCO2 and Simultaneous monitoring of dual Temp (1 Core and 1 Skin). Should have interface module to anaesthesia workstation. It should display inspired and expired anaesthesia gas monitoring with automatic identification of agent and MAC values. .

1

-

-

... More
Laryngoscope Fibre optic Adult Laryngoscope Macintosh blade set of size 1-4 Fiber optic Paediatric Miller blade set of size 0 & 1 Standard Handle with LED Lamp for both adult and paediatric.

1

-

-

... More
Videp Laryngoscope with disposable blades

1

-

-

... More
Endotracheal tube Thermo sensitive tube which soften at body temperature to conform to the anatomy of the respiratory tract. Kink resistant inflation tube ensure patient safety during cuff inflation and deflation. Low Pressure Cuff to reduce the risk of creasing or inflation and minimizes pressure on trachea wall. Soft, high volume, low pressure cuff to provide an air tight fit between tube and trachea. Radio opaque line throughout the length to facilitate exact location of the tube Sizes: 5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10 mm

1

-

-

... More
Nasal Airways • Flexible for maximum patient comfort • Tube manufactured in medical grade PVC soft, flexible and kink resistant. • Soft material for enhanced nasal passage comfort. • Atraumatic soft-rounded edges and smooth surface. • Specially designed bevel tip reduces mucosal trauma during insertion. • Tube marked with the internal diameter for easier size identification. • Thin wall construction provides maximum inner diameter. • Interior walls with channel grooves facilitate easy insertion of catheter. • Removable 15 mm connector to allow connection to ventilation systems. Sizes : 6.5, 7, 7.5, 8, 8.5mm

1

-

-

... More
Oral Airways • Airways designed to maintain an unobstructed oropharyngeal airway during or following general anaesthesia and in patients who are unconscious for other reasons. • Integral hard bite block to avoid airway occlusion and biting of tongue. • Stepless airway path for easy cleaning. • Bite blocks colour coded for instant identification of sizes. • Manufactured from non toxic, non-irritant polymer PE. • Sizes: 000, 00, 0, 1, 2, 3, 4, 5.

1

-

-

... More
Magill’s Forceps Manufactured from high quality medical stainless steel. Angled forceps to guide tracheal tube into the larynx or a nasogastric tube into the oesophagus under direct vision or to place pharyngeal packs and remove foreign body. Set of Adult, paediatric & Infant sizes.

1

-

-

... More
Multipara Monitor with PR, NIBP, ECG, SpO2 Suitable for Adult, paediatric & neonatal patient monitoring. Monitor PR, NIBP, ECG, SpO2, Dual Temperature as standard parameters. 3/5 Lead ECG Inbuilt rechargeable battery backup at least 2 hrs. Nellcore / MASIMO SpO2 technology. Should have capability for Invasive monitoring. ST analysis, Arrhythmia detection. 12’’ TFT-LCD colour touch screen display with min. 2 to 7 channels of waveforms simultaneously.. Defibrillator and ESU protection. Able to display at least 120 hrs of trend and 60 events with waveform, Nurse call, VGA output port, USB port, inbuilt three channel recorder as standard. European CE/US FDA certificate.

1

-

-

... More
Electrical Suction Apparatus Plastic moulded housing on two wheels with foot switch & changeover lever Max. Vacuum / LPM: -600 mm Hg, 60 Ltrs / min Pump Type: Double Diaphragm pump Jars: 2 x 4 Ltrs. Polysulfone (PSU) Jars Filter: Bacterial Filter Autoclavable / Reusable Tubing: 10 mm ID x 2 mtr. (PVC) Vacuum Gauge: 6.25 cm dia 0-760 mm Hg Power Supply: 220 V AC, 50 / 60 Hz, 180 Watt Noise Level: 55 dB A ± 3 Overflow Safety: Mechanical & Electronic Sensor Certifications: CE

1

-

-

... More
LMA of all sizes

1

-

-

... More
PLMA of all sizes

1

-

-

... More
Spinal Epidural Set Continuous Epidural Anesthesia Kit 18G with LOR, Filter and 3 pair of Catheter Opening Latex free continuous epidural anesthesia kit containing G18/G16 epidural touhy needle with large crystal clear grooved transparent hub & epidural catheter of G20 /G 19 & length 100 cm. With catheter connector. Epidural catheter in the kit is made of 2 layers - inner layer of Polyamide & outer layer of Polyurethane. Epidural catheter has an atraumatic tip design - the catheter has a tapering tip upto 4 cm & 3 pairs of laser drilled holes for distribution of drug. The kit also has a small compact ergonomic 0.2 micron epidural filter

1

-

-

... More
Spinal Pencil Point Needle Spinal Needle with pencil point tip having 1 mm side hole opening, having clear transparent groved hub and color coded stylet intorducer needle 20G x 13/8". Size 25 G x 3 1/2" (0.53 x 88 mm) & 27G x 31/2" (0.73 x 88 mm)

1

-

-

... More
Spinal Epidural Set Combined Spinal Epidural Catheter Set With Back Eye Touhy Needle Latex free disposable pencil point spinal needle 27G, 127.5 mm with grooved transparent hub with centering protective plastic sleeve, Touhy needle with back eye - 18 G (1.3 x 88 mm). Protrusion of spinal needle through the back eye of the epidural needle. With epidural catheter, filter, loss of resistance syringe and separate locking device - Docking System

1

-

-

... More
Simple Anaesthesia Machine with resuscitation equipments and accessories Anaesthesia Delivery Machines (Boyle’s Apparatus) Should be Suitable for Trauma, Minor Operating Rooms Adult and Paediatric applications Facility and Connections for 2 Gases: Oxygen and Nitrous Oxide. The machines should have the facility for Low Flow Anaesthesia procedure with the placement of 4 Tube Rotameters / Flowmeters. Anti-Hypoxia Guard that ensures a minimum of 25% Oxygen supply. Nitours Oxide Cut Off System. OFWD alarm system in case of Oxygen Failure. Low Battery Alarm. High / Low Pressure Alarm Connection of a Selectatec Bracket back bar to mount Tec. Vaporisers Should be supplied with Vaporiser. Connection of Pin Index Cylinders and Pipeline Connections for supply of gases. MS Metal Frame + FRP Fibre Body.

1

-

-

... More
PNS (Peripheral Nerve Stimulator) Nerve Stimulator-Mapper-Locator for Muscle relaxation monitoring/ Neuro Muscular Blockage Agent (NMBA) monitor for General Anesthesia and Nerve Blocks during Regional Anesthesia. Portable Battery operated small sized unit Should have Mapper and Locator functions related to Nerve Blocks during Regional anesthesia Transcutaneous Nerve Mapping with Nerve Mapper Probe at higher current of 0-20 mA Real time Graphical representation of the actual waveform delivered Nerve Proximity indicator with audio-visual feedback User adjustable Pulse Width and frequency User should be able to pre-program 20 different current and Pulse Width settings Should have separate mode for Muscle relaxation monitoring (NMBA) with Single Twitch, Repeat Twitch, Train of Four, TET, DBS, PTC Should have TriAxial Accelerometer for real time graphical feedback display of strength of contraction. Auto Sensing function between Nerve Mapper cable, Nerve Locator cable and NMBA cable without changing setting on the unit Current ranges : Nerve Locator : 0-5 mA Nerve Mapper : 0-20 mA NMBA monitoring : 0-80 mA Complete unit with Nerve Stimulator probe with Accelerometer, Separate Nerve Location cable and Combined Nerve Mapping and Location cable. Must have ISO 13485 and CE certificate.

1

-

-

... More
Resuscitation Equipment (CPR)- Ambu bag with face mask 100% Silicon Material Sizes : Adult / Paediatric

1

-

-

... More
Pulse oximeter Compact pulse oximeter, min. 7” display, should display parameter SpO2, Plethysmograph, Signal strength and Pulse rate.

1

-

-

... More
E.C.G. Machine 12-Channel ECG with advanced algorithm for interpretation - using age, gender and race to accurately analyse ECG. Multi-format reports. Large colour touch screen, Should support external USB printer, Should have Wi-Fi, DICOM, FTP, Bar code reader and PC Connectivity.

1

-

-

... More
ABG Machine Suitable for patient’s bed-side tests for quick result. Parameters should be available with different combination of cartridges: Blood gas, Electrolyte, critical chemistries, hematology, coagulation, cardiac enzymes, etc. Tests using whole blood should be available. Cartridge based system for quick results and ease in use.

1

-

-

... More
TOF Monitor (PNS) Nerve Stimulator for Muscle relaxation monitoring TOF (Train of Four) / NMBA (Neuro Muscular Blockade Agent) Monitor. Should be portable Battery operated small sized unit. Should have Tri-Axial Accelerometer for real time graphical feedback display of strength of contraction. Should have separate modes for Muscle relaxation monitoring (NMBA) with TOF-Train of Four, DBS, PTC, TET, Twitch. Real time Graphical representation of the actual waveform delivered. Should be able to display TOF waveform as well as actual TOF ratio. Auto Sensing of NMBA cable. Current range : 0-80 mA. User adjustable frequency. Complete unit should be with Nerve Stimulator probe with Accelerometer. Must have ISO 13485 and CE certificate.

1

-

-

... More
Rac’s Catheter

1

-

-

... More
Intrathecal infusion pumps Pump and catheter part of an implantable, programmable drug infusion system that store and deliver medication into the intrathecal space. Combined with the Control, to eliminate systemic opioids and provide effective pain relief. Smart software to guide the clinician through programming the system, via information and warning screens Full-body MRI compatibility at 1.5 and 3-Tesla under specific conditions. Critical therapy and patient data stored in the pump for follow-up at other institutions. Flex dosing schedules should allow drug delivery to be matched to patient needs, providing chronic pain relief throughout the day Should have a separate touchscreen interface compatible with the pump. Should have simple steps for refill and implant. Built-in auto-calculations for volume and rates. Software for patients who can alleviate their unpredictable pain without the use of systemic opioids. One can set a therapeutic daily dose and allow patients on-demand bolusing within limits. Feature of clear and informative bolus confirmations, lockout details, and alerts. Should be easy and simple to use.

1

-

-

... More
Pain assessment Chart

2

-

1

... More
OT Table (fluoroscopy compatible) Four Section eccentrically positioned radio-translucent table top without cross members to facilitate C-arm imaging. The table top made of radio-translucent material for excellent fluoroscopic capability. Operating positions i.e. Height adjustment, Trendelenburg, Reverse Trendelenburg, Lateral Tilt and Back Section precisely controlled by handheld Remote.The powered movements actuated by Electro-hydraulic System comprising of hydraulic motor pump with low noise level of less than 50dBA and solenoid valves to assure smooth and quiet movements. The Head and Leg Section removable and interchangeable, capacitating a single table’s use in varied surgical procedures. These are manually operated by means of ratchet system.Built-in Kidney Elevator – manually gear operated. Non-corrosive SS304 Grade Stainless Steel base and cylinder covers, side-rails, clamps and standard accessories. Table top size (L x W) : 1900 x 500 mm Height : 750 mm - 1000 mm Trendelenburg / Reverse Trendelenburg : min ± 20° Lateral Tilt (Left/Right) : min. ±15°Back section adjustment : + 80° – 20° down Leg section adjustment : + 15° – 90° Head section adjustment : +45° – 90° down, Variation ±10% Load capacity : 180 KgsPower supply : 220V AC – 50HzWith Orthopaedic attachments.

1

-

-

... More
Nerve Locator Nerve Stimulator for Nerve blocks under Regional Anesthesia or Nerve Locator for Regional Blocks. Portable Battery operated small sized unit. Should have combined Mapper and Locator functions related to Nerve Blocks during Regional anesthesia. Battery: Should run on any 9V (alkaline) batteries.Stimulation current: 5 mA max (0-12 k), Stimulation Voltage: 95V Stimulation frequency: 1 Hz / 2 Hz, Allowable load impedance: 0 k – 12 Stimulus duration : 1.0 ms - 0.5 ms - 0.3 ms - 0.1 ms - 0.05 ms Digital dial for Precise and tactile current adjustment with convenient tactile feedback. Sense function stimulation duration- SENSe (0.10 ms - 0.10 ms - 0.15 ms to 1.0 ms) Current measuring accuracy: +/- 0.02 MaImpedance measuring range: 1 KOhms - 90 KOhms for target stimulation current 0.5 mA The enlarged full graphics LC display having good visibility with wide angle of view. The following information should be displayed on the stimulation screen at all times: Stimulus amplitude in mA (large digits)Current range: Stimulus duration in ms Stimulus frequency in Hz Load impedance in kΩ Direct access keys: Direct access keys to let conveniently adapt the most important and frequently used settings to the clinical environment. (Amplitude range - mA, stimulus duration - ms, stimulus frequency - Hz). Sequential electrical nerve stimulation (SENSe) - Featuring the option of selecting a frequency of either 1 Hz, 2 Hz or 3 Hz for SENSe and a stimulus duration of 0.05 ms - 0.10 ms - 0.30 ms -0.50 ms - 1.00 ms. It should have following Safety Features: Threshold current - To visually and acoustically indicate when the stimulus duration-dependent current threshold goes out-of-tolerance indicating that the needle may be too close to the nerve. Visual warning: The full digits of the target current display converted to contoured digits when the current threshold drops below the preset level. The LED flashing yellow (instead of green). Acoustic warning: A warning signal should be additionally sounded. Auto Adjust current feature - the current adjusting automatically when the stimulus duration is changed. Accessories: Pen: The Pen for percutaneous nerve mapping to help to pre-assess the puncture site. Also suitable for training sessions.

1

-

-

... More
Computer 10th Generation Intel® Core™ i5 processor 8 GB DDR4-SDRAM 2 TB 7200 rpm SATA NVIDIA® GeForce Windows 10, Microsoft Office.

1

-

-

... More
Anodyne Machine (for diabetic foot care) Designed to provide foot and leg pain relief by increasing foot and calf circulation. The pain relief technology should deliver two 30-minute treatments in between a 20-minute cooling cycle and has an auto shut-off feature that activate after each 80-minute session. Should have comfortable foot and calf therapy pads to increase circulation over a total therapeutic surface area.

1

-

-

... More
Transcutaneous Electric Nerve Stimulating Machine Should be Non Invasive Radio Frequency Pain Management using Neuro Modulation Portable Battery operated small sized unit Should be Useful for treatment of: Chronic Pain Relief, Neuropathic Pain & Symptoms, Diabetic Neuropathies, Bell’s Palsy, Trigeminal Neuralgia, Tennis Elbow, Golfer’s Elbow & Regional Pain Syndromes. Square wave output with a Superimposed RF Waveform Graphical Display with backlight Output Current range of 0-30 mA Transcutaneous Nerve Mapping with Nerve Mapper Probe On Board timer to keep track of Therapy Time User adjustable Pulse Width 0.1 ms and 0.2 ms User adjustable Frequency of 1,2,5,10 Hz Must have ISO 13485 and CE mark

1

-

-

... More
Crash Cart With Polystrene boxes and drawers with medicine container of different sizes Structure made of 25mm square pipe thickness 1.6mm. Two salves made of 1mm ss sheet with rail (three sides). ABS six drawers raised at the middle with centre locking. Six small container raised inside the upper drwers for keeping the sutures. One spot led light fitted at the centre of the trolley. Sliding salve fitted at the left side of the trolley with push handle. Diffib perforated tray fitted at the top (detouchable). IV pole, cylinder carrier provission. Wall guard fitted at the bottom.(wholly ss) Six colored bins fitted under the diffib tray (detouchable). Finish with glossy polish. Mounted on 100mm caster two with break. Over all size: 750mm(l)x400mm(w)x1500mm(h)

1

-

-

... More
Nerve Stimulator 5Ch fully digital with digital treatment timer along with Soft Key Touch for Treatment mode Selector & auto mode Selector.To relieve Pain effectively in Arthiris, Neuralgia, Migraine, Spinal Disc, Surgical Trauma, Headache, Sciatica etc. Treatment Mode: : 7 Mode (Normal, Burst, Accup., Conventional, Sweep, Pwm, Diadynamic) Program: 12 Programs (6 Program in Monophasic and 6 Program in Biphasic) Frequency Range: 1 to 200Hz(Normal Mode) Sweep Frequency: 1-100Hz, continuously Adjustable Treatment Time : 60 minutes Display: LCD Display Intensity: 0-60mA Current Type: Monophasic and Biphasic Output: Dual Channel Output Voltage Waveform: Square and Rectangular continuously variable Pulse Power Supply: 12 VDC AdapterBattery; 9V Rechargeable battery

1

-

-

... More
Epidural Needle 18G

1

-

-

... More
Multimedia Projector with screen • Brightness: 3600 lm • Projector Type: XGA | Chipset: LCD • Maximum Projection Distance: 10.4 ft • Lamp Life: 5000 hr • Resolution: 1024 X 768 pixel • Aspect Ratio: 4:3 • Wireless Network Connectivity Pull down Screen 84Inch- Diagonal Approx. 4 feet (height) x 6 feet (width) In 4:03 Aspect Ratio.

1

-

-

1

-

-

1

-

-

-

-

-

-

-

-

-

-

-

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.