Drinking Water And Sanitation Department Tender

... More
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Drinking Water And Sanitation Department - DWSD Tender

Works
Electrical Goods and Equipments
Machinery and Tools
Electrical and Electronics
Eprocure
Opening Date20 Jan 2025
Closing Date26 Jan 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Quotation Of Rates For Supply Installation And Commissioning Of Pump Set And Electro Mechanical Works And Repair Works From Reputed Manufacturers Authorized Dealers Having Valid Gstin Of Materials.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cost towards making new P.C.C foundation with supplying stone chips, sand, cement, in the ratio 3:2:1 respectively about 4.5’x3’x3’for above pump sets including foundation bolts with nut and washer and curing plastering of foundation ,all complete .

1

10

-

... More
installation& commissioning of free standing type floor mounting industrial panel board comprising 100 amp copper bus-bar 4 nos. in M.S steel (14SWG) housing and consisting of 100 amp T.P.N DTH MCCB-1no incoming feeder and 63 amp T.P.N DTH MCCB-3 nos. outgoing feeder ( 1 no. standby) ,0 to500v voltmeter -1 no, 0to 200 amp ammeter-2 nos. with selector switch ,indicating lamp for 3 phase, single phase preventer, 32 amp MCB-1 No and 63 amp switch fuse unit-1no for internal& external lighting load, and doing internal connection with copper wire etc

1

10

-

... More
Cost of supply & laying, commissioning of 3 core 10 mm² copper conductor cable 30 M 1.1 KV grade PVC insulated and PVC sheathed unarmored from panel to starter and starter to motor with lugs socketing

30

10

-

... More
Cost towards replacement of damage cable by new supply, & laying ,commissioning of 3.5 core 25 mm² Al conductor cable ,1.1 KV grade PVC insulated and PVC sheathed armored from Transformer to change over switch to stabilizer to panel in air as were as required with lugs socketing , making connection all complete.

70

10

-

... More
Supply, fitting & commissioning of lighting arrangement at intake pump plant and gangway such as tube light 20 W complete set 4 no and 70 W LED lamp complete set 3 nos. and making wiring, light point, fan point etc. as required.

1

10

-

... More
Supply and fitting 100 amp switch fuse unit-1 no before stabilizer on the wall, including required materials such as clamp, nut, bolts, etc, for the job , make – L&T, Havell’s, any Reputed make ISI Marked

1

10

-

... More
Cost towards making earthing connection from earth pit to change over , stabilizer ,panel, starter, motor with 6 SWG G.I wire

30

10

-

... More
Cost towards replacement of old & damage voltage stabilizer by providing, erecting and testing ,commissioning of 50 KVA oil cooled Servo Controlled Automatic Voltage stabilizer at Intake-well pumping plant Prasabad, suitable for Output voltage - 415 ± 1% ,3 phase, 50 Hz with copper wound transformer as mention below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range 10% . The stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling necessary monitors and users control on front panel such as indication, alarm, voltmeter and selector switch, Raise/Low push buttons, etc. suitable capacity termination strips and bus bar for incoming and outgoing, All three phases shall be independently monitors and corrected , Input -150/220 Volt-460 Volt, Output- 415 ± 1% , speed of correctin-35 V/second, Regulation + 1% from no load to full load , Ambient temperature 0 to 55 degree centigrade (Designed for indoor /outdoor continuous operation ) Operation –automatic cum manual , MCB for short circuit & over load protection, over voltage / under voltage protection, single phasing preventer, cut off contactor with electronic output sensing unit . Make- Power line /Servokon.

1

10

-

... More
Supplying and filling trans former oil of best quality in stabilizer

350

10

-

... More
Providing and fixing 100 AMP. TPN on/ off load change over switch with side handle operation, in sheet enclosure with allied materials, ISI Marked

2

10

-

... More
Repairing of 10 H.P C/F Pump set – 1No.:- Cost towards dismantling 10 H.P C/F Pump set and changing its damaged parts such as – S.S shaft sleeve as per sample size and shape – 2 nos., S.S shaft sleeve check nut as per sample size and shape – 2 nos. including S/F SKF bearing- 2 Nos. , coupling- 1 set, gland tightner – 1 set, and repairing shaft as where as required, impeller , balancing rotating unit, re-assembling with allied materials and , including loading, unloading, transportation etc. all complete and testing at site

1

10

-

... More
Cost towards providing labor, tools & technician for dismantling and disconnecting sq. cage induction motor and taking out rotor from stator, cutting and removing burnt coil, cleaning and repairing all stator slots properly with cost of reassembling stator and rotor of motor, fitting the motor on base plate, making all power connection, testing on full load, including transportation cost of motor from P/P to workshop and vice-versa.(15K.M x2)

1

10

-

... More
cost towards providing labor, tools & technician for full rewinding of 10 H.P sq. cage induction motor’s stator with supply of supper enameled round suitable size copper conductor and insulating material class-F insulating materials such as Dr. back varnish, cotton tape, wooden stick, etc .making coil and doing rewinding with making coil & inserting coil into stator slots properly, making connection phase to phase and coil to coil, varnishing heating, taping, sleeving, baking in control temperature up to obtaining proper resistance all complete. (Wt of wire about 8 Kgs) and S/F SKF ball bearing on driving and non driving end. with deducting the cost of taken out burnt wire, scrap materials.

1

10

-

... More
Raw water pumping plant, Bekobar:- Cost towards supply, installation& commissioning of V.T. pump set at Raw water pumping plant, Bekobar, capable of discharging 45 M³/ H ( 9912 G.P.H ) against a total head 48 meter (157.44 feet ) WPIL /Jyoti / Kirloskar / Wilo coupled with a suitable SPDP vertical hollow shaft /solid shaft V.T sq. cage induction motor, operation able on 3 phase, AC , 50Hz ±5%, 415V±10%, rpm 1400 to 1500, make- Jyoti /Kirlosker/ C.G with suitable discharge head, base plate, and accessories such as- suitable M.S column pipe flanged type 60 ft ( 10 ft long -5nos , 5 ft long -2 nos.), spider bearing, line shaft, cat less-bush, foot valve with strainer, pressure gauge, double flanged C.I sluice valve rating PN-1.6 & double flanged type C.I N.R valve rating PN-1 etc. making delivery pipe line as required ,dismantling installed pump set, all complete . testing of pump set on full load at site .

2

10

-

... More
Cost towards supply and fitting 20 H.P fully automatic air break star delta starter , Make- L&T /Havell’s/ siemense / schiender/ BCH

2

10

-

... More
Cost of construction P.C.C foundation with cement, sand, stone chips (1:2:4),foundation bolt nut ,spring washer ,plastering, punning of foundation , and making delivery pipe, with piping works required for the job , etc all complete.

2

10

-

... More
Cost towards replacement of damage panel by new supply, installation& commissioning of free standing type floor mounting industrial panel board comprising 100 amp copper bus-bar 4 nos. in M.S steel (14SWG) housing and consisting of 100 amp T.P.N DTH MCCB-1no incoming feeder and 63 amp T.P.N DTH MCCB-3 nos. outgoing feeder ( 1 no. standby) ,0 to500v voltmeter -1 no, 0to 100 amp ammeter-2 nos. with selector switch ,indicating lamp for 3 phase, single phase preventer, 32 amp MCB-1 No and 63 amp switch fuse unit-1no for internal& external lighting load, and doing internal connection with copper wire etc.

1

10

-

... More
Cost of supply & laying, commissioning of 3 core 16 mm² copper conductor cable 30 M 1.1 KV grade PVC insulated and PVC sheathed unarmored from panel to starter and starter to motor with lugs socketing,

40

10

-

... More
Cost towards replacement of damage cable by new supply, & laying ,commissioning of 3.5 core 35 mm² Al conductor cable ,1.1 KV grade PVC insulated and PVC sheathed armored from Transformer to change over switch to stabilizer to panel in air as were as required with lugs socketing , making connection all complete.

140

10

-

... More
Supply, fitting & commissioning of lighting arrangement at intake pump plant and gangway such as tube light 20 W complete set 4 no and 70 W LED lamp complete set 3 nos. and making wiring, light point, fan point etc. as required.

1

10

-

... More
Supply and fitting 100 amp switch fuse unit-1 no before stabilizer on the wall, including required materials such as clamp, nut, bolts, etc, for the job , make – L&T, Havell’s, any Reputed make ISI Marked.

1

10

-

... More
Cost towards making earthing connection from earth pit to change over , stabilizer ,panel, starter, motor with 6 SWG G.I wire

200

10

-

... More
Cost towards replacement of old & damage voltage stabilizer by providing, erecting and testing ,commissioning of 50 KVA oil cooled Servo Controlled Automatic Voltage stabilizer at Intake-well pumping plant Prasabad, suitable for Output voltage - 415 ± 1% ,3 phase, 50 Hz with copper wound transformer as mention below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range 10% . The stabilizer should be constructed in cubical box,with bidirectional wheels for easy handling necessary monitorsand users control on front panel such as indication, alarm, voltmeter and selector switch, Raise/Low push buttons,etc. suitable capacity termination strips and bus barfor incoming and outgoing, All three phases shall be independently monitors and corrected , Input -150/220 Volt-460 Volt, Output- 415 ± 1% , speed of correctin-35 V/second, Regulation + 1% from no load to full load , Ambient temperature 0 to 55 degree centigrade (Designed for indoor /outdoor continuous operation ) Operation –automatic cum manual , MCB for short circuit & over load protection, over voltage / under voltage protection, single phasing preventer, cut off contactor with electronic output sensing unit . Make- Power line /Servokon.

1

10

-

... More
Supplying and filling trans former oil of best quality in stabilizer

440

10

-

... More
Providing and fixing 100 AMP. TPN on/ off load change over switch with side handle operation, in sheet enclosure with allied materials, ISI Marked

2

10

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.