Building Construction Department Tender

... More
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Building Construction Department Tender

Coronavirus COVID 19
Eprocure
Opening Date28 Oct 2019
Closing DateCancelled
Tender Amount₹ 12,38,92,78,588 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing & Fixing Multi Bolt Sash Lock with Strike Plate Left/Right both side operation with cylinder , key hole cover & knob for one side Lock for Aluminium Door Shutters Body & SS finish, with necessary screw etc. complete in all respect.

259

-

-

... More
1 Set of 250 A 4P MCCB 25 KA miroroprocessor based controlled with overload, short circuit and earth fault protections.

-

-

-

... More
2. Pre filter section with Wire mesh SS Filters for coarse particle removal.

-

-

-

... More
4 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Max. Setting Min. Setting

-

-

-

... More
230V AC/ 24V DC ,Stabilized Power Supply with voltage trimmer - 1 Set.

-

-

-

... More
2. The rate for each item of work included in the Schedule of Quantities shall, unless expressly stated otherwise, include cost of :

-

-

-

... More
3 No. adjustable Frequency drives.

-

-

-

... More
VAV-02-1F-H 3430 1029

1

-

-

... More
35mm thick Metal Door SIZE 1500MM(W)X2400MM(H) Double Shutter, frame Including MS Hardware.(8nos. 100mmx75mmx3mm MS Butt Hinge, 4nos.250mm Long D-Type MS Handle Fabricated MS 20mm dia ROD, 2 nos.250mm MS Aldrop, MS Louver as per Drawing Finished painted as per approved colour) complete in all respect.

171

-

-

... More
Heat Rejection of Each tower : 1228500 Kcal/Hr

-

-

-

... More
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.

128

-

-

... More
Earth Bus - Copper - 1 Set

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
(xxvi) AH-2F-04 24 21700 4

1

-

-

... More
(i) Domestic pumps (2W+1S+1 Jockey) for filter water system flow : 40.00 m³/h, head : 40.00 m; Jockey Pump of capacity 5 m3/hr ; head 40.00 m (Composite Electrical Control Panel in built with pump set, so no need quote for extra item for control pannel)

2

-

-

... More
SLP-01 (SUB LIFT PANEL-01 ) ( THIRD FLOOR - EAST & WEST BLOCK) / SLP-02 (SUB LIFT PANEL-02 ) ( ROOF - EAST & WEST BLOCK) / SLP-07 (SUB LIFT PANEL-07 ) ( ROOF - EAST & WEST BLOCK) / SLP-08 (SUB LIFT PANEL-08 ) ( THIRD FLOOR - EAST & WEST BLOCK) as per direction of Engineer-in-charge.

8

-

-

... More
2 Set of 100/5A CTs of 10 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
13 Sets of 40A 4P MCBs, 10KA

-

-

-

... More
For 80mm dia Pipe

10

-

-

... More
(vi) 600 mm width X 75 mm depth X 2.0 mm thickness

40

-

-

... More
Supply, Installation, Testing & Commissioning of Electromagnetic Lock as per detailed Technical specifications with all accessories complete as required as directed by Engineer in Charge.

38

-

-

... More
(g) 80 mm nominal bore.

4

-

-

... More
FLOORING FOR VISION IMPAIRED :-Providing and laying VITRIFIED Tac Button tile (300mmx300mmx15mm) flooring (for vision impaired persons as per standards) of size 300x300x15mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make & design in all colours and shades for indoor & outdoor floors as per drawing & design., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete in all respect as per direction of Engineer-in-Charge.

6293

-

-

... More
Supply, Installation, Testing & Commissioning of 15Mtrs HDMI Cable : Crystal-clear video up to 4K DCI (4096 x 2160 @ 30Hz), 4K UHD (3840 x 2160 @ 30Hz), and 1080p @ 60Hz signal HDMI Ethernet Channel functionality: additional dedicated data channel supports networking HDMI (3D, Deep Color, 4K) and HDCP 2.2 compatible Gold-plated connectors for reliable transmissions as per directed by Engineer in Charge 15 mtrs in Length RoHS-compliant

3

-

-

... More
VAV-01-1F-H 1670 501

1

-

-

... More
Supply, Installation, Testing and Commissioning of Recess LED 595 X 595mm fitting made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Diffuser, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) =100lumens/watt, Life of fixture 50000hrs@L70%, Lumen maintenance, CCT 5700k or 6500k , CRI 80, PF 0.95, an operating Voltage Range of 140 - 270 V. Minimum glare office compliant with UGR19. The total Power Consumption should be within 30W to 40W(including driver), Minimum system Lumens 3600. Philips Models RC380B LED 36S PSU W60L60 OD OC or eqiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification Required: LM 79 & LM 80. Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

1584

-

-

... More
VAV-02-GF-F 3686 1106

3

-

-

... More
Supply, Installation, Testing & Commissioning of of 4:1 Switcher It should Allows up to four HDMI A/V sources to be connected to one HDMI display. It should Quick and easy switching between HDMI sources via front panel pushbuttons, RS-232 or IR Remote control. It should support long distance transmission up to 15 m (24 AWG). It should have Supports 340MHz bandwidth for ultrahigh 4kx2k video. It should support HDMI (3D, 4KX2K,Deep color) and should be HDCP 2.2 compatible. it should have Auto switching modes for auto port selection. it should support Max. Data Rate 9 Gbps (3 Gbps Per Lane). it should have LED indication of video source devices. it should support Max. Pixel Clock 300 MHz. It should support Dolby True HD and DTS HD Master audio. It should have Built-in bi-directional RS-232 serial port for high-end system control. it Supports IR extension using a IR extension cable. It should Instant switching between HDMI input sources. "it Supports resolutions of up to Up to 4096 x 2160 / 3840 x 2160 @ 60Hz (4:2:0); 4096 x 2160 / 3840 x 2160 @ 30Hz (4:4:4)." It should support Operating Temperature 0-50°C. Storage Temperature -20 - 60°C. Humidity 0 - 80% RH, Non-Condensing. It should support I/P rating 100-240 VAC; 50-60 Hz; 1.0A. Consumption 120 VAC, 36.6W; 230 VAC, 37.5W as per directed by Engineer in Charge

1

-

-

... More
VAV-02-3F-G 2145 644

1

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Supply, Installation, Testing and Commissioning of Electrical Control Panel in common cubicle with suitable compatmentation for Booster Pumps mentioned in sl.nos 1.29 above as per requirment of the drives and with auto on/off logic and operational sequence as per specifications with all meterial, accessories, instrumentation etc.complete.( GA drawing including circuit diagram shall be submitted by the contractor and to be approved by the Owner/consultant before fabrication of the control panel). Note : Cost shall be inclusive for approval of fire hydrant & sprinkler system from local fire authority and Fire Emergency services and any other relevant statutory authority at initial & various other stages of works, including preparation of report / drawings as per fire authority. Contractor shall include cost of all liaison works which are not explicitly mentioned above but are mandatory to have fire authority approval (any statutory charges will be reimbursed as per actual upon production of the invoice / challan informer of the owner as per direction of Engineer in Charge.

12

-

-

... More
Incoming

-

-

-

... More
Incoming

-

-

-

... More
1 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
12 WAY (8+36), Double door, Vertical type (Power SDB)

150

-

-

... More
Local / remote selector switch

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Room Humidity & Temperature Transmitter

4

-

-

... More
Supply installation testing and commissioning of BTU Meters for chiller water and flow measurements in closed or open loop chilled water supply systems with two flow measurement channels, two pressure measurement channels, two pulse inputs for additional flow sensors and pre-programmed or measured pressure values may be used for energy calculation. Cold water temperature for open loop application can be measured, or pre-programmed temperature value can be used. Optional integrated regulation or alarm function with flexible menu setup – list of parameter values displayed on the LCD to be configured according to the customer’s needs. Power supply – from internal battery or 230 V AC power source. Battery lifetime not less than 10 years. Optical data interface according to EN 61107 Communicating Type as per directed by Engineer in Charge

-

-

-

... More
Supply, Installation, Testing, & Commisioning of Novec 1230 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and Restrictions. as per direction of Engineer in Charge.

8800

-

-

... More
For size 150 mm long (OZ-TB- S6")

76

-

-

... More
Incoming

-

-

-

... More
VAV-08-3F-G 2900 870

1

-

-

... More
b) 150 mm dia

172

-

-

... More
i) 150 mm nominal size dia having minimum wall thickness 5.00 mm

48

-

-

... More
VAV-02-2F-F 1755 527

1

-

-

... More
(a) 1000 A 4P ACB – 1 No.

-

-

-

... More
(b) 100 mm nominal bore.

1020

-

-

... More
Outgoing

-

-

-

... More
2 Nos. 100 Amps TP MCCB,50 KA, Thermomagnetic Protection controlled.

-

-

-

... More
Providing & Fixing Glass for Vision Area of Structural Glazing system/Aluminium Window ST -467 Antelio Plus of Saint Gobain or Equivalent ( for other make as below) coated toughened blue green shaded glass in DGU (outer:6mm with coating face +12mm air gap+inner 6mm clear) for GRIHA Rating outside Light Transmission of 39% , Solar factor of 0.36 and U-Value of 2.8 W/sq.mtr.K ,shading co-efficient 0.41 with all fittings fixtures etc. complete as per direction of Engineer in Charge.

13332

-

-

... More
25mm dia

87

-

-

... More
Operation of the high side and low side of the air-conditioning system comprising of all the machinery, VRF system - outdoor, indoor unit, piping and controls, air handling units, heat recovery units, ventilation fans etc. during operating 12 hours per day for the defect liability period of one year as per the maintenance schedule "Appendix-H" of CPWD specifications for HVAC works-2007. Rate to be quoted shall be per month. As Direction of E/C

24

-

-

... More
1 Set of 320/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Extra for depth beyond 45 cm of brick masonry chamber: For 500 x 700 mm size With common burnt clay F.P.S (non modular) bricks of class designation 7.5

28

-

-

... More
(xiv) VFDs in suitable enclosure shall be installed near the equipments for motors of following ratings:-

-

-

-

... More
2 Nos. 40 Amps TP MCCB,50 KA, Thermomagnetic Protection controlled.

-

-

-

... More
Providing and fixing over head Shower 105 mm dia round shape Jaquar cat no. OHS-CHR- 1709, with Revolving Joint along with Shower arm casted 190 mm long light body round shape for wall mounted showers with flange chromium plated Jaquar cat. No. SHA-CHR-477 or equivalent as per direction of Engineer in Charge.

49

-

-

... More
1 no. 100A 4P MCCB, 25 KA Thermomagnetic controlled. with overload, short circuit and earth fault protections.

-

-

-

... More
Providing and fixing earth bus of 50 mm X 6 mm copper strip 0.50 meter below ground as strip earth electrode, including connection etc. as required as per directed by Engineeer in Charge. (For T/F And DG Neutral Earthing )

80

-

-

... More
(xii) 0-25 A Ammeter with ammeter selector switch & 25/5 CT's - 02 Sets.

-

-

-

... More
1 set of 3 Nos suitable rating Protection class CT for REF relay for Transformer feeder.

-

-

-

... More
(iv) 300 mm width X 50 mm depth X 1.6 mm thickness

100

-

-

... More
Bothside 120 minutes fire resistance HABITO / Fire block plaster board/ Tufbloc board of approved make complete in all respect as per direction of E/I

2276

-

-

... More
Outgoing

-

-

-

... More
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile

1207

-

-

... More
Supplying and fixing following 240 V, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
a) 100 mm dia M.S. 900 bend with arrangement for fixing Pressure gauge.

12

-

-

... More
2 Set of 800/5A CTs of 10 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)

400

-

-

... More
(iii) 200 mm width X 50 mm depth X 1.6 mm thickness

1200

-

-

... More
Interior Lighting :- Decoration as per Drawing & Design (Material paid in separate item )

8

-

-

... More
Bus Bar

-

-

-

... More
Pair of Hand Gloves suitable for 12 kV as per directed by Engineeer in Charge.

4

-

-

... More
Supplying, installation, testing & commissioning of CAT6A Patch Cord (Rack End) as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

756

-

-

... More
Condenser Water Inlet Temperature: 32.2 deg C

-

-

-

... More
Incomer

-

-

-

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement providing and fixing painted CI frame and cover of size 300X300 weighing not less than 7.2Kgs with locking arrangement fixing the frame in CC 1:2:4 including form work, curing, etc complete as per standard design as per direction of Engineer-in-charge:: With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

36

-

-

... More
UMDB-LGF UPS MAIN DISTRIBUTION BOARD) ( LOWER GROUND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 2 as per direction of Engineer-in-charge

2

-

-

... More
1 no. 250A 4P MCCB, 25 KA microprocessor controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
3 Nos. ACB (EDO Type) microprocessor based 4P, 4000A 65 KA with O/L, S/C & E/F releases

-

-

-

... More
VAV-04-2F-F 4560 1368

1

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
6x125 kVAr LT power capacitor banks with 6 No 100 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
150 mm dial type pressure gauges for suction and discharge of each pump.

-

-

-

... More
VAV-03-1F-D 3270 981

1

-

-

... More
VAV-01-3F-F 2910 873

1

-

-

... More
Lettering Size 300 mm. Height in english & hindi

28

-

-

... More
Shunt trip coil. - 2 Sets

-

-

-

... More
100mm dia

56

-

-

... More
(xxxi) AH-3F-03* 37 34700 4

1

-

-

... More
VAV-10-GF-A 3810 1143

1

-

-

... More
450 mm dia NB pipe 4.85 mm thick plate

230

-

-

... More
VAV-06-1F-E 2915 875

1

-

-

... More
2 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
VAV-01-1F-E/05-3F-F 2285 686

2

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work

1000

-

-

... More
Outgoing

-

-

-

... More
1x12.5 kVAr LT power capacitor banks with 1 No. 10 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
10.0 Rates shall be inclusive of all sundries whether it is mentioned in BOQ/ specification or not. Rates to be quoted for complete SITC for the purpose stated in the basis of design.

-

-

-

... More
VAV-01-1F-C 4050 1215

1

-

-

... More
Bus Bar

-

-

-

... More
Providing weep holes in Brick masonry / Plain /Reinforced concrete abutment, wing wall / return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications.

550

-

-

... More
Shunt trip coil. - 1 Set

-

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

20

-

-

... More
VAV-08-1F-A 3390 1017

1

-

-

... More
2 Sets of 2000 A 4P ACBs 50 KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings.

-

-

-

... More
2 Sets of 1000/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
VAV-06-1F-H 2390 717

1

-

-

... More
(i) 15550

1

-

-

... More
VAV-05-2F-D 2720 816

1

-

-

... More
2 Core x 4 Sq.mm Cable

300

-

-

... More
(xxvii) AH-2F-03* 21 18900 4

1

-

-

... More
Capcaity ( CMH) Static Pressure ( mmof H2O)

-

-

-

... More
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in bullding specification).

362

-

-

... More
Waterproofing of Lift Pit: Providing and laying water proofing treatment on Lift Pit consisting of following :-(Measurement on floor & wall treated area separately & Rate is inclusive all items)1.Surface Preparation: All surfaces to receive the waterproofing to be mechanically cleaned properly so that there will be no dust, laitance, oil, grease etc. 2.Coving:Coving to be done at all junctions by cutting V grooves of prescribed size and filling with cement-sand (1:4) mortar admixed with (Sika Top 77 /Fosroc Nitobond SBR Latex/BASF Master Emaco SBR2)of approved manufacturer with their direction. 3.Water proofing product:-Supply and application of a non shrink, expanding grout admixture with suitable material ( Intraplast EP/ Brushbond RFX/ Master Flow 150) of approved manufacturer with their direction, by pressure grouting inside RCC floor & treated wall upto Ground Floor (upto 3.00mtr.) after 28 days of curing using 12mm dia, 75 mm long GI nozzles 1.5 m C/C in the concrete.Next Supply and application of an water proofing inside RCC floor & wall upto plinth appropriate coating of approved manufacturer with their direction. (Rate is inclusive of necessary repair for damage portion after installation of Lift ) 4.Covering with Screed plastering:-After curing Providing and applying 12mm thick plastering with Cement Mortar 1:4 admixed with integral waterproofing admixture ( Plastocrete Plus/ Conplast WL/ Master PEL 777) of approved manufacturer with their direction on wall & floor complete. As per direction of Engineer in Charge.

1912

-

-

... More
Supplying, installation, testing & commissioning of cubical type LT panel suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized as per IEC-60439, design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. zero halogen fire retardant insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears.(General arrangement and schematic Drawings to be approved by the Dep't. before start of fabrication) as per direction of Engineer-in-charge.

-

-

-

... More
(i) HRU-LGF-03- 2200 CMH Ceiling Suspended

1

-

-

... More
Supplying, fitting and fixing 150 x 20 x 6mm L-type M.S. clamp properly fishtailed, including making holes and setting the Same in 200x125x75mm Cement concrete block (1:2:4) with cost of all labour and materials and taxes as per building specification and direction of the Engineer-in-charge

478

-

-

... More
H D - 20 Circular shape 560 mm internal diameter

128

-

-

... More
Joint For 40MM Width Cover

280

-

-

... More
8 way,Double door (Power SDB)

102

-

-

... More
Incoming

-

-

-

... More
(iii) 4250 CMH at SP at 15 mm WG

10

-

-

... More
Each unit shall be First Charge of Refrigerant, required foundation , Power cabling from MCB to indoor unit , Powder coated Adjustable Height Indoor Stand and outdoor stand for Outdoor condenser.unit shall have inbuilt sequential controller for operating unit in N+1 confguration. Microprocessor should have inbuilt features of Team Mode and cascade mode. hard drawn insulated copper refrigerant piping complete with fittings not less than 18 Gauge thick including extra charge of refrigerant and oil as required, complete with fittings between indoor units and remote condensers. 3CX 2.5 sqmm armoured power cabling as required between indoor and outdoor unit. Cabling shall be supported properly in a neat & clean manner using GI cable trays. As Direction of E/C

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. (b) Extra depth for 120 cm x 90 cm manhole beyond 0.90 m depth.

608

-

-

... More
Providing & fixing 18mm thk Granite door frames of any approved colour (No joint allowed) upto 200mm width vertical 2pcs. both amalgamated with approved quality bonding adhesive in vertical jambs & soffit, as per drawing & design fixed on walls with necessary backing material, & 90mm long stainless steel screw (3 nos. each vertical stone ) with rawl plug including machine polish , necessary edgemoulding , each smooth joint, providing position for hinge & rivet for shutter on exposed edges and rounding of corners, and joint filling compound of same shade of Granite with all Lead & Lift,royalti,taxes etc. complete in all respect as direction of Engineer in Charge.

2330

-

-

... More
VAV-07-1F-A 1815 545

1

-

-

... More
Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of the Engineer-in-charge

18724

-

-

... More
Supplying, installation of 1U Panel Wiring Duck on Front as per directed by Engineer in Charge

788

-

-

... More
120 mm dia (OD-120mm & ID - 103 mm nominal)

13500

-

-

... More
870 KVAR (Seleected actual Rating may be 1086.5KVAR) LT Capacitor Panel-1 as per directed by Engineeer in Charge.

1

-

-

... More
DDC- 42

2

-

-

... More
Top roof should be well ventilated, especially with ventilation provided on the vertical side of the roof to enhance the hot air outflow while in operation. Roof should also have provision to mount atleast 4 nos. of 90 CFM cooling fan trays and there should be space for the cable entry from the top. Thickness of powder coating should be 60 microns or more. Colour of the cabinet should be Black The structure and all its components should be made from CRCA Steel Material – at least 1.2mm thick The rack should be provided with 1 Heavy Duty Shelf of 390 mm Depth. Vertical power distribution units provided should have 6 outlets of 5/15 amp capacity. All cables used should be of ISI grade with 2.5sq mm cross sectional area. All the connecting ends must be tinned so as to avoid any loose wire strands. Rack should have the appropriate mounting provision for the multiple of these PDUs at the rear of the rack. Each Rack should be provided with one numbers of such power distribution units. Certifications: RoHS as per directed by Engineer in Charge.

-

-

-

... More
VAV-05-1F-C 3310 993

1

-

-

... More
Communication cable & accessories & Software for PLC programming with mimic diagram-1 Set

-

-

-

... More
Protection Relays,TVM/MFM Shall have RS 485 Modbus/Profibus Communication protocol for SCADA / BMS communication.

-

-

-

... More
Breaker control switch - 1 Set

-

-

-

... More
VAV-03-2F-F 2730 819

1

-

-

... More
Supplying, installation, testing & commissioning of DMX Lighting Controller, a powerful and user friendly interface with USB 2.0 interface, Controls up to 1024 DMX channels, All connections are made to front and back panels, 8 I/O ports, 3 buttons, display, DMX input. Starting scenes can then be carried out in sequential access by using «previous» and «next» on the box or via the external “I/O ports” connector which triggers off up to 255 scenes in direct access. New generation of DMX interface has many improvements: a new look with injected box, 3-pin XLR, extended stand alone memory, internal connector, easy assembly with external cable,

2

-

-

... More
65mm nominal bore

86

-

-

... More
VAV-03-2F-B 5835 1751

1

-

-

... More
(ii) Dia 200 mm (8.0 mm thick)

959

-

-

... More
A set of Sump pumps (Non-clogging type) having discharge capacity of each pump approx.10 cum/hr at 15 m. pumping head (2 working, 1 standby) Suction from sumps in in Lower ground floor, delivery to surface drain at ground level. Including MCC and allied works

4

-

-

... More
(ii) 250mm dia

24

-

-

... More
NS ITEMS Supplying & laying approved quality of outside earth arranged by the contractor and filling in foundation trenches or in & surrounding plinth including upto ground floor level including dressing, compaction with necessary watering in layers not exceeding 150mm thick with all leads and lifts, loading & unloading including cost of all materials, labour,royalty and taxes all complete as per building specification and direction of E/I(Mode of measurement compacted volume).

20

-

-

... More
(f) 65 mm nominal bore.

20

-

-

... More
6. In the event of an error occurring in the amount of the Schedule, as a result of wrong extension of the unit rate and quantity, the unit rate quoted by the tenderer shall be regarded as firm and the extensions shall be amended on the basis of rates.

-

-

-

... More
FOR DOOR SIZE- 2000MM(WIDTH)X2500MM(HEIGHT) Double Leaf Shutter.

110

-

-

... More
JSR ITEMS Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l.

616535

-

-

... More
50 mm dia

1

-

-

... More
Supply, Installation, Testing & Commissioning of Eight Channel Digital Power amplifier, 8 x 250Watts @ 4Ω, Bridgeable to 4 X 500Watts @ 8 Ohm; Power Amp Topology : Class D, Convection cooled, Hypex Inside, Power Supply : SMPS; Protection Circuit : Over Current, Over temperature; Frequency response : 20 - 22KHz; S/N ratio : 100 dB A-Wieghted; THD : 0.5% A Wieghted; 2U 19" rackmount as per directed by Engineer in Incharge.

2

-

-

... More
SITC of Air Terminal 2 mtr. side wall ,confirming to EN 62561 and according to IS/IEC 62305 as per direction of Engineer-in-charge

32

-

-

... More
Supply, installation, testing & commissioning of intelligent aspiration detector for area coverage of minimum 5000 sq. ft. complete as required.

6

-

-

... More
Bus Bar

-

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

3492

-

-

... More
(iii) 63 A 4P MCCB - 04 No.

-

-

-

... More
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm

3010

-

-

... More
VAV-06-2F-E 2465 740

1

-

-

... More
b) Providing and fixing Cast Carbon Steel ASTM – A 216, Gr. WCB Double Flange Gate Valve as per BS : 1414 : API – 600, Class – 300 Rising Spindle of Stainless Steel AISI : 410 and Internal Working Parts Stainless Steel AISI : 410. Flange Drilled as per ANSI B-16.5, Class – 300, Raised Face, With Hand Wheel Operated. Hydraulic Test Pressure of Body – 78 Kg / Cm2 and Seat 58 Kg/Cm2 approved quality as per direction of Engineer in Charge.

-

-

-

... More
b) Providing and fixing Cast Carbone steel double flange swing type Non Return Valve class 300 as per B.S 1868 inter working parts of S.S 304 Hydraulic test pressure of body 78 kg/cm2 seat 58 kg/cm2 approved quality as per direction of Engineer in Charge.

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Cables suitable for DDC System, complete with terminations, junction boxes, glands, accessories etc.. The cables shall be clamped on to the cable trays / wall / ceiling using heavy duty GI clamps & screws.

-

-

-

... More
2 core 1.0 mm², PVC insulated, multi stranned tinned annealed copper conductor cable - unshielded.

-

-

-

... More
PMDB-FF (POWER MAIN DISTRIBUTION BOARD) ( FIRST FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 2 as per direction of Engineer-in-charge

2

-

-

... More
Load / Speed: As mentioned below /minimum 1.00 Mtr. Per Second

-

-

-

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket ,fixing fittings(Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)

47956

-

-

... More
1200 mm dia. R.C.C. pipe.

388

-

-

... More
4 Nos. 125 Amps TP MCCB,50 KA, Thermomagnetic Protection controlled.

-

-

-

2

-

-

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing Tap Off Box including drilling holes in cubicle panel, making connections, etc. as required as per direction of Engineer-in-charge.

-

-

-

... More
3.5 C x 240 sq mm A2XFY cable

7190.99

-

-

... More
(ii) AH-LGF-03 (A) 9 7450 4

1

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
Providing integral waterproofing compound of approved manufacturer & direction for mixing ratio for outside Plastering work as per direction of the Engineer-in-charge. ( Note:- Using this Waterproofing Compound conforming to IS 2645 shall be added as per manufacturer specification minimum .@2% by weight of cement mixing with mortar for external plastering work or as required)

711092

-

-

... More
6 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
a) 15 KW Motor - 01 No.

-

-

-

... More
g). Connectivity to PA system,

-

-

-

... More
1 no. 100A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Outgoing

-

-

-

... More
63mm dia

578

-

-

... More
Bus Bar

-

-

-

... More
8 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
1 Set of 250 A 4P MCCBs 50 KA miroroprocessor based controlled with overload, short circuit and earth fault protections.

-

-

-

... More
Base Frame & Foundation :

-

-

-

... More
Bus Bar

-

-

-

... More
Supplying and laying 25 mm X 3 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) as required. as per direction of Engineer-in-charge.

504

-

-

... More
7 no. 20A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
(xiii) 0-6 A Ammeter with ammeter selector switch & 6/5 CT's - 04 Sets.

-

-

-

... More
Safety stud anchor M12x115/20

4

-

-

... More
Supplying, installing, testing and commissioning of Video wall retractable bracket (Make-Standard) as per directed by Engineer in Charge

4

-

-

... More
;It should have Simple profile setup with easy configuration steps via intuitive GUI. it should Allows administrators central control of multiple rooms via profiles on a mobile device or tablet computer. ; it should Max. No. Allowed 10 licenses.'it support Any iOS, Android, or Windows mobile device can be used to control the system – no need to purchase costly exclusive user panels ; it should Restrict user access to profiles via password authentication; it should Synchronization of system controls amongst multiple mobile devices and tablet computers. It should have LED indication of connection and hardware status ;It should be Rack Mountable; It should support Operating Temperature 0-50°C. Storage Temperature -20 - 60°C. Humidity 0 - 80% RH, Non-Condensing; It should support I/P rating 100-240 VAC; 50-60 Hz; Power Consumption 40W as per directed by Engineer in Charge.

-

-

-

... More
6/32 amps,Single pole, "C" series

17912

-

-

... More
Exhaust Fan - 6" - 1 No.

-

-

-

... More
Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: (a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. (b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge.

-

-

-

... More
Supply, Installation, Testing & Commissioning of 55" 4K LED display,  Panel Technology: IPS, Resolution:3,840 x 2,160 (ULTRA HD),brightness:500nits, Contrast ratio-1000:1, Dynamic Contrast ratio-1000000:1,Connectivity: HDMI,DVID,DP,RS232C,RJ45,IR, Audio, RS232C, USB 3.0, SD Card slot, Built in WiFi, Quad Core Processor/SOC , Dust/Humidity Protection-Conformal coating, Typical power consumption-120w or less, Features-Temperature Sensor, Auto Brightness Sensor, At least 15x15Tile Mode, ISM Method, USB Cloning, Contents Scheduling, Sync mode, PM mode, Fail Over, Wake on LAN,  Certification- UL / cUL / CB / TUV / KC, FCC / CE / KCC as per directed by Engineer in Incharge.. .

4

-

-

... More
4000 A, 415V, 4 strip, 65 KA, 50 Hz Aluminium Bus bar

-

-

-

... More
Providing and fixing C.P on brass Sink mixer with swinging casted round shape spout (Wall mounted model) and wall flanges, {Jaquar, Clarion (Quarter Turn), Cat. No. CQT - CHR - 23309 or approved equivalent} as per direction of Engineer in Charge.

161

-

-

... More
Matching air cooled condenser with copper tubes and aluminium fins duly covered by anti-corrosion and hydrophillic resin film.

-

-

-

... More
1. Above price shall be excluding end termination.

-

-

-

... More
(vi) Star Delta / DOL starter with ON/OFF indicating light, ON/OFF push buttons, control fuses, timers, contractors, overload relay with built-in single phase preventor, control fuses, wiring, interconnections suitable for following rating motor.

-

-

-

... More
Kitchen sink without drain board. (i) 610mm x 510mm bowl depth 200mm.

163

-

-

... More
VAV-05-2F-A 1975 593

1

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

4240

-

-

... More
Incomer

-

-

-

... More
(ii) 11050 CMH at SP at 20 mm WG

4

-

-

... More
OUTDOOR PTZ DOME CAMERA Supply, Installation, Testing & Commissioning of Networkable,, High Performance, Outdoor Dome PTZ Camera with 1/2.8" progressive scan , 2 Megapixel ,4.3 -129 mm Lens, 2 simultaneous streams and 1 Service stream, 60FPS, Sensitivity : Color 0.008 lux Mono 0.001 lux True Day & night type , H.264 / Motion JPEG Video Compression, 1920 x 1080 , 130 WDR Must or Better ,30X Optical and 12x digital zoom, Three Automatic Defog, OptionsShutter Range 1/1 ~ 1/10,000 sec or Better, 3D Noise Filtering, Electronic Image Stabilization (EIS), Support Upto 2TB Edge Storage, , Housing, Connectors, Lens, and all mounting accessories with OEM warranty minimum 3 years as per the given detailed specifications as directed by Engineer in Charge. At the Entry / Exit Gate Locations.

4

-

-

... More
Providing and fixing gun metal non- return valve of approved quality (screwed end) :

-

-

-

... More
(ii) 0.63 mm

5615

-

-

... More
VAV-01-GF-C 1055 317

1

-

-

... More
160mm diameter

2287

-

-

... More
Providing and fixing of Motorised fire dampers with actuator, control panel approved by CBRI, Roorkee, as per UL -555, fire rating for 2 Hours.. Price shall be inclusive of control module, related control wiring and stepdown transformer. Damper shall be with TDF flanges. Actautor shall be wired over MODBUS RS485/BACnet/Open protocol. All other parameters as per the technical specifications given in the tender . As Direction of E/C

132

-

-

... More
4 C x 16 sq mm A2XFY cable

15311.96

-

-

... More
3. All PTs should be Draw out type.

-

-

-

... More
3 no. 630A 4P MCCB

-

-

-

... More
12 way,Double door (Connecting Corridor Lighting SDB)

22

-

-

... More
Constructing brick masonry road gully chamber/catch pit 50x45x60 cm with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) including 500x450 mm precast RCC horizontal grating with frame complete as per standard design: with common burnt clay F.P.S (non modular) bricks of class designation 7.5

1284

-

-

... More
Hi Wall Type Units

-

-

-

... More
a) 1.1 KW - 01 No.

-

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Arches, domes, vaults up to 6 m span.

6036

-

-

... More
2 no. 20A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
a) 11 KW - 01 No.

-

-

-

... More
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.

30

-

-

... More
Licensed software for Runtime application -1 Set

-

-

-

... More
Outgoing

-

-

-

... More
VAV-05-1F-A 1410 423

1

-

-

... More
Providing and fixing Bell plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I).a)150 mm dia

12

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 No- 3 pin 5/6 A modular socket outlet and 1 No- 5/6 A modular switch, connections etc. as required.

3996

-

-

... More
Supply, Installation, Testing, & Commisioning of Abort Switch

48

-

-

... More
6. Multi Function Meter(MFM) shall have following parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, THD.

-

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 pipes.mm gap for thermal expansion, (i) Single socketed Pipes as per directed by Engineer in Charge. (i) 160 mm diameter.

6278

-

-

... More
2 Sets of 1000/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineerin- Charge.80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern.

16088

-

-

... More
Bus Bar

-

-

-

... More
600 mm width x 50 mm depth x 2.0 mm thickness

986

-

-

... More
(iv) 6 HP ( Single Phase)

12

-

-

... More
Bus Bar

-

-

-

... More
Removal and disposal of surplus excavated earth by mechanical transport including loading unloading ,stacking and spreading at all lift and lead up to 2KM approved by Engineer in charge(For Other than Civil Work)

366

-

-

... More
Supply, Installing, testing and commissioning of  10GBASE-LRM SFP Module with 5 year warranty as per directed by Engineer in Charge

676

-

-

... More
Extra for Labour charges Over 3metre height for Brick work in C.M. ( 1 : 6) in superstructure for each floor/over Roof

7968

-

-

... More
(v) 2635 15

1

-

-

... More
4 Strip aluminium bus bar of 300 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
1 Set "ON /OFF" push button with 2A, 3P MCB, 10KA

-

-

-

... More
Incomer

-

-

-

... More
(i) 12550

1

-

-

... More
Supplying, installation of Velcro Cab le Management Tie, Roll 50Mtr as per directed by Engineer in Charge

172

-

-

... More
Accessories:-Supply installation, testing and commissioning of 'Y' and header refrigerant joints for liquid line and suction line including channels, supports, clamping arrangement and all safety measures for the item above. As Direction of E/C

2

-

-

... More
Liquid Level Switch, 2m cable

6

-

-

... More
1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
b) 22 KW - 03 No.

-

-

-

... More
Providing and fixing soil, waste and vent pipes : 100 mm dia Sand cast iron S&S pipe as per IS: 1729

160

-

-

... More
DDC- 1

2

-

-

... More
• Electrical Control Panels - 1 Set

-

-

-

... More
(iv) 27370 CMH at SP at 22 mm WG

4

-

-

... More
Supplying, installing, testing and commissioning of a wireless digital desktop chairman conference unit connecting to the conference system via the antenna module, operating in 2.4 GHz and the 5 GHz frequency band, built-in PCB antennas with pattern diversity and a coverage area of 30 m (100 ft) radius, adjustable RF output power from 25 to 100 mW, 128-bit AES encryption, rechargeable battery pack with an operating time of more than 20 hours, microphone key with a bicolor LED ring for microphone status indication functioning as on/off switch or as a request-to-speak button, next key to allow speaking privileges, priority key to deactivate all active conference units, high-performance broadband twin loudspeaker system with frequency response of 100 Hz to 14.5 kHz, integrated DSP limiter to protect against excessive input signals, option to connect super-cardioid gooseneck microphone, 3.5 mm headphone socket and a headphone volume control with headphone output level of minimum 50 mW / 16, THD (at 1 kHz) shall be 0.03 % at 50 mW / 16, Signal-to-noise ratio 70 dB(A) as per directed by Engineer in Charge..

1

-

-

... More
(h) 80 mm nominal bore.

4527

-

-

... More
DDC- 26

2

-

-

... More
Supply, Installation, Testing & Commissioning of Multifunctional stereo pre-amplifier with power supply 115 - 230 VAC; zone outputs: 2 stereo; zone outputs: 2 stereo; total harmonic distortion THD (%) 0.008;with music level control, VCA level control; 5 nos balanced MIC inputs; Phantom power voltage: 20 volts; 5 nos mono balanced line input; RS232 (serial communication port) optional; frequency response (in Hz) 20 - 22 k; with applicable low impedance; power consumption (max) :24 watts; 6 nos balanced output level (dB); signal to noise level SNR (dB) 93; crosstalk (dB) 70;with MIC level control and source selection per zone; 5 inputs with Phantom power, with noise gate on MIC; 4 nos stereo unbalanced line input unbalanced; with emergency input and 4 nos priority levels; applicable in 100V as per directed by Engineer in Charge.

1

-

-

... More
(ii) Star Delta / DOL starter with ON/OFF indicating light, ON/OFF push buttons, control fuses, timers, contractors, overload relay with built-in single phase preventor, control fuses, wiring, interconnections suitable for following rating motor.

-

-

-

... More
Designer Jali work on 25mm thick Teakwood with polish finish.

32

-

-

... More
Outgoing

-

-

-

... More
(i) 63 A TP MPCB - 02 No.

-

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. for chlorination chambers 15 mm nominal outer dia Pipes

91

-

-

... More
Bus Bar

-

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
Drive: MICRO PROCESSOR BASED VVVF - CLOSED LOOP/V3F

-

-

-

... More
Supplying, installing, testing and commissioning of wireless digital Handheld Microphone with 18 or more channel, RF output 100mW or more, super cardiod pickup pattern, Frequency range : 1880 to 1930 MHz, Connectivity : RJ-45, Battery backup : 17 or more hr etc and complete as required with 1 nos 2 port charger of same OEM as microphone as per directed by Engineer in Charge

2

-

-

... More
(i) 0-300 Ammeter with Ammeter selector switch and 300/5 C.T.s -1 Set

-

-

-

... More
(xxxvii) AH-3F-09 (CS) 13.2 10750 4

1

-

-

... More
Supplying, installation, testing & commissioning of Blank Plate for LIU (OM4) as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

120

-

-

... More
Supply, installation, testing, balancing and commissioning of powder coated extruded aluminium 2 way 3 Slot supply Diffuser of given size in the drawings with guide vanes, Dampers, Plenum chamber etc., as required and complete as per specifications.

47

-

-

... More
2 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Supply, Installation, Testing, & Commisioning of Novec 1230, CCOE Approved 150.0 Ltrs. Cylinder working at 34.5 bar pressure with Valve Assembly and arrangement for Supervisory Switch connection for monitoring cylinder pressure, a pressure gauge with a safety burst disc and safety cap. as per direction of Engineer in Charge.

50

-

-

... More
Supply and fixing acoustic lining with 25 mm thick mineral wool density 48 kg/cum confirmimg to IS : 8183-1993 wrapped in glass cloth on the inner side of ducting including fixing in the aluminium frame work and finishing the same and covered with 0.63 mm perforated aluminium sheet as per specifications for ducts & as required. As Direction of E/C

3636

-

-

... More
VAV-03-1F-C 5108 1532

1

-

-

... More
Fuel Tank :

-

-

-

... More
Oil flow meter 80 NB with flanged end for bulk storage

2

-

-

... More
2 Nos, 250 Amps TP MCCB, 50 KA, Thermomagnetic Protection controlled.

-

-

-

... More
Supply of 300mm sweep, 900 rpm, 1 phase Exhaust fan of approved make with ISI mark, with heavy duty louvers shutter, complete with frame, as required complete. Sample luminaire shall be got approved by Engineer-in- charge / consultant. FITTING & FIXTURE

72

-

-

... More
VAV-04-2F-F 2655 797

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
3 C X 300 sq. mm (70mm)

8

-

-

... More
LIFT:- Design, Fabrication, manufacture, assembly, delivery to site, installation, testing, commissioning and handing over of lift having contract speed of 1.0 m/sec serving different floors in the existing lift shaft as per detailed specifications enclosed, codes, lift rules, IS, as per instruction of E.I.C and as under : (Charges for Minor Civil & ancillary Work , Scaffolding for Errection,Maching Lifting arrangement Pit & Shaft temporary Lighting arrangement , Temporary Locking Shed for Erection Person and one year of defect liability after handing over are included in this item)

-

-

-

... More
a) 1.1 KW Motor - 02 No.

-

-

-

... More
Supply, installation, testing and commissioning of pressure independent AHRI certified variable air volume (VAV boxes) consisting of BACnet /MSTP commubicable DDC controller,damper actuator, low pressure velocity transducer and temperature sensor ( with digital room thermostat). integral sound attenuator made of 22 Gauge GI sheet, casing consisting of 25 mm thick 48kg/m³ density rock wool, volume control damper, caliberated diffrenetial pressure sensor at inlet complete with controller, control wiring etc. as required and as per specificaiton and drawings. VAV should be dynamically calibrated & tested in factory on live test bed as per designed CMH. As Direction of E/C

-

-

-

... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.M.S. Tube / Hollow Section

2164

-

-

... More
2 no. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
(viii) 0-63 A Ammeter with ammeter selector switch & 63/5 CT's - 12 Sets.

-

-

-

... More
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).

-

-

-

... More
Supply, Installation, Testing & Commissioning of 18 U Rack which should have 4 nos. castors. All castors should be without any brake or any other locking mechanism Front door – Front Vented Glass door should be provided with 2 locks for the security purpose. This door should have provision to get mounted on Right or Left side of the rack front. This means that it should be possible to change the door configuration from Left to Right at site. It should also be possible to open this door by 180 Degrees to ensure proper approach to front of rack Rear door should be completely perforated to facilitate the air circulation at the maximum without offering any resistance to the same. Ideally, it should be possible to remove it easily and should have 2 locks for the security purpose. Rear doors should have provision to mount fan trays. Side Panels should be easily removable type along with the provision for locking. Ideally, the panels should have latching arrangement to facilitate easy removal and putting back the panel along with locks for the security purpose Height - The Rack should Provide 18U Usable Space Width – The rack should be 600mmW with 19” mounting provisionDepth – The rack should be at least 600mmD. Usable Depth should be not less than 500mmLoad carrying capacity of rack should be 500 KgMounting rails (for Standard 19" mounting) should be made up of steel. (Minimum 2.0mm thickness) and should be of Multi-fold design for enhanced loading capacity and rigidity. It should have unique U Marking along with U locator notch. U Number Markings should be clearly visible even after mounting of the equipment Two Numbers 1U Cable Manager should be provided along with Metal Loops for Cable Dressing as per directed by Engineer in Charge.

1

-

-

... More
VAV-04-GF-A 2895 869

1

-

-

... More
VAV-01-2F-C 3150 945

1

-

-

... More
(viii) 0-40 A Ammeter with Ammeter selector switch & 40/5 C.T.s - 03 Sets

-

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick

200992

-

-

... More
Bus Bar

-

-

-

... More
Supply, Installation, Testing and Commissioning of Meeting room Scene set –– Min. 7 buttons consisting of: 4 presets, Dim up/down & Off button. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

7

-

-

... More
1 Set of 1000/5A CTs of 10 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
150 mm width x 50 mm depth x 1.6 mm thickness

7036

-

-

... More
Lubrication oil pressure indication

-

-

-

... More
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.

-

-

-

... More
3 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
5 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Supplying, installation, testing & commissioning of CAT6A 24 Port Patch Panel, T568 A/B Wiring for Voice as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

608

-

-

... More
(ii) Recycled Water (2W +1S+1 Jockey) for flushing system flow : 20.00 m³/h,head : 40.00 m ; Jockey Pump of capacity 5 m3/hr ; head 40.00 m (Composite Electrical Control Panel in built with pump set, so no need quote for extra item for control pannel)

2

-

-

... More
VAV-04-1F-C 2020 606

1

-

-

... More
FLOORING FOR VISION IMPAIRED :-Providing and laying Stainless Steel 316(Marine Grade) Directional Bar , Minimum Sizes top 280mm, depth of top portion 5mm, width 50mm, Bottom depth 17mm of 6mm dia having griping option 3 nos.. Fixed on any marble/granite flooring groove with polyurethane sealant, complete in all respect as per direction of Engineer-in-Charge.

120

-

-

... More
• Humidity: Max. 95%

-

-

-

... More
Engine mounted instrument Panel fitted with and having digital display for following:

-

-

-

... More
Supply, Installation, Testing & Commissioning of 0.6 Mtrs HDMI Cable : Crystal-clear video up to 4K DCI (4096 x 2160 @ 30Hz), 4K UHD (3840 x 2160 @ 30Hz), and 1080p @ 60Hz signal HDMI Ethernet Channel functionality: additional dedicated data channel supports networking HDMI (3D, Deep Color, 4K) and HDCP 2.2 compatible Gold-plated connectors for reliable transmissions 0.6 mtrs in Length RoHS-compliant as per directed by Engineer in Charge

2

-

-

... More
Engine Fault Relay

-

-

-

... More
24 Core x 2.5 Sq.mm Cable

12

-

-

... More
(xi) 0-16 A Ammeter with ammeter selector switch & 16/5 CT's - 02 Sets.

-

-

-

... More
(vi) 10 A TP MPCB - 10 No.

-

-

-

... More
Stair Railing :- Design, Supply and installation of Stainless Steel Grade 304 Railing System comprising of Baluster and 110 x 60 mm Base Plate with provision of Holes. 3 Nos. of Mid Rails of 25 mm Dia. and 12mm Dia. hole for pipes to be tightened with Allen Screws. The Hand Rail of 50 mm dia to be installed to the Baluster using SS Screws at 50mm Center distance. The average distance between 2 balusters to be 900 mm and the ht of Railing is 900 mm. Finish Satin completed in all respect as per direction of the Engineer in charge. (SHOP DRAWING TO BE PROVIDED & DULY APPROVED BEFORE EXECUTION OF THE WORK).

536

-

-

... More
150 mm width x 50 mm depth x 1.6 mm thickness

87.975

-

-

... More
(a) 500 liter capacity-(8 Nos Tank)

8000

-

-

... More
Armoured 2 Core x 1 sq mm FRLS Al-Mylar Screened with drain wire, Cable for control cabling as per directed by Engineer in Charge

46000

-

-

... More
(i) 300 A 4P MCCB - 04 No.

-

-

-

... More
1 no. 20A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 meter). (364.20+127)=491.20

1520

-

-

... More
Lettering Size 450mm. Height in english & hindi

172

-

-

... More
Outgoing

-

-

-

... More
Supply of Network Switch : 24 port layer 2 switch with 10/100/1000 Managed Switches with IP multicast snooping and data-driven IGMP support and with Two 1000baseT single mode FO uplink ports (with Fiber Module ) and all related termination accessories as per site specific System requirement.Price should include any other accessories required to complete the system configuration as per vendor specific requirements i.e. Power supplies, fiber converters, LIUs, Specific System cables, patch cords, labels, pigtail cables, etc. to complete the installation successfully as per directed by Engineer in Charge.

36

-

-

... More
Teak wood framework with necessary fixing arrangment to floor & Ceiling and polish finish with fillar for jali work.

7.62

-

-

... More
Outgoing

-

-

-

... More
Providing and filling sand of grading zone V or coarser grade all-round the G.I. pipes in external work.

-

-

-

... More
(iv) 350 mm dia

322

-

-

... More
Auxiliary contacts required for necessary interlocking of breakers.

-

-

-

... More
Cast steel ball valves 50mm dia

24

-

-

... More
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

1210

-

-

... More
Providing and fixing Hand dryer Satin Finish ABS body EURONICS make model Cat No. EH02 or approved equivalent for VIP areas as per direction of Engineer in Charge.

20

-

-

... More
(a)Hydro Pneumatic System Pumps set Consists of: 3 non-self-priming, vertical stainless steel high-pressure centrifugal pumps with, impellers and diffusers as well as all parts in contact with the fluid made of stainless steel or of corrosion-resistant materials, bidirectional mechanical seal and 3-phase motor. For every pump with gear-operated ball cocks on the suction/pressure side and a non-return valve on the pressure side, 300 ltrs diaphragm pressure vessel incl. flow fitting in accordance with DIN 4807, 2 pressure gauges and pressure sensor (4 -20 mA), ready for connection with 1.4571 stainless steel pipework, mounted to electrolytic galvanized base frame with height-adjustable vibration absorbers including solenoid valves, level switches etc., at roof tanks. Note: (required control panels will be paid under sl.no 1.1.2 below)

-

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia

960

-

-

... More
p) Call pickup (Group & Individual)

-

-

-

... More
(v) 25 A TP MPCB - 02 No.

-

-

-

... More
CB Close PB Green - Test Push Button with 1 NO Contact - 1 No.

-

-

-

... More
All MCCB upto 160A Shall be Thermomagnetic and MCCB Greater than 160A shall have Micro processor based release All CTs and PTs shall be cast resin type of Class 0.5

-

-

-

... More
Supply, Installation, Testing & Commissioning of 2x2 Full HD Video Wall considering 55” IPS, LED, FHD panel, Hard coating, Anti-glare surface treatment , Bezel Width: Less than 1 mm (L/T/R/B) even bezel , Brightness: 500 cd/m2 or higher, Dynamic CR: 500000:1, Built in system - 1.2Gzh Quad Core CPU, 550MHz GPU, 2.5GBDDR3 RAM & 8GB storage or higher, SRC, Typical Power Consumption 150W or less per panel, atleast 15x15 Tile Mode, Weight per panel not more than 26KG, USB Cloning as per directed by Engineer in Incharge.

2

-

-

... More
ACSDB 03 AHU ROOM : Supply, installation, testing and commissioning of following distribution boards totally enclosed compartmentalized, cubicle floor mounted, indoor type IP:42, factory fabricated with 2 mm thick sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply suitable for 25 KA as per specifications and drawings. All Air Circuit Breakers shall be provided with Micro processor based Earth fault, short circuit and over current releases. Moulded case circuit Breakers shall be microprocessor based electronic trip. Fault level for all ACB/MCCB and bus bar shall be 25 KA, all the motor feeder shall be type-2 coordinated. ICU shall be equal to ICS=100%. As Direction of E/C

2

-

-

... More
Auxiliary contacts required for necessary interlocking of breakers.

-

-

-

... More
(xviii) AH-1F-02* 25 23900 4

1

-

-

... More
1 Set of 250/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Note: All required accessories shall be provided for 3 Nos- DG Sets.

-

-

-

... More
(i) 150 mm nominal bore.

2

-

-

... More
Providing & fixing danger plates made of mild steel at least 2mm thick & vitreous enameled white on both sides & with inscriptions in signal red colour on front side as required as per directed by Engineeer in Charge.

-

-

-

... More
Providing & fixing Medium grade Door Handle suitable for Mortise lock Left & Right operation of approved design & finish for Flush Wooden Door complete in all respect as per direction of Engineer in Charge. Material SS304 & SS finish.

916

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Supplying, fitting and fixing full body SS Water Cooler for drinking purpose of storage capacity not less than 20 liters, cooling capacity 20 liters/hour with 1or 2 taps, ecofriedly refrigerant R134a or superior, hermatic type compressor equipped with overload protection, thermostat control, condenser fan, power supply 230volts, 50 Hz, single phase power plug and electrical lead wire connection upto 3 metres from the water cooler, water inlet and drain out connections complete in all respects as per direction of Engineer in Chargesimilar to Voltas/ Usha make or similar approved make - (Model - USHA 20 L Stainless steel 2020-SS).

104

-

-

... More
50mm nominal bore

28

-

-

... More
(vii) 34700

1

-

-

... More
(x) AH-GF-02 21 16600 4

1

-

-

... More
b) 5.5 KW Motor - 01 No.

-

-

-

112

-

-

... More
b) 3.7 KW Motor - 02 No.

-

-

-

... More
Door Shutter Framework for Fire rated Glazed Door :-Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc. all complete as per direction of Engineer-in-charge ( Glaze paneling to be paid for separately).

192

-

-

... More
VAV-03-1F-A 1340 402

1

-

-

... More
3 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Each capacitor bank must have 1 set of on/off indication LED type.

-

-

-

... More
VAV-01-2F-E 2515 755

1

-

-

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire [Lift Shaft Light Points] / [Plumbing Solenoid walls on roof.]

3950

-

-

... More
BOLLARD : LED 9W(±10%) Mushroom shape bollard luminaire is made in 3 parts comprising of:- 1) Spun aluminium, white powder coted inside mushroom shaped top cover. 2) Cylindrical clear acrylic.3) Seamless GI pipe bottom housing the control gear for 9W(±10%) LEDs. Color temp. 3000K, Color Rendering Index ≥70, Total Harmonic Distortion 10%, Driver Efficiency 85%, IP 65, PF 0.95, Surge Protection 4KV.Luminaire Performance: IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification: LM 79 & LM 80 Certificates. Min Delivered Lumens: 630(±10%) lumen, Standard Deviation Colour Matching (SDCM) 4, an operating Voltage Range of 180 - 240 V, similar to Bajaj Cat. No. BLBMC 9W LED WW or equiv. Sample luminaire and paint shall be got approved by Engineer-in- charge / consultant.

480

-

-

... More
(i) 75 mm diameter.

22

-

-

... More
2 Sets of 1600/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
(iv) R,Y,B indication LED light with 2A MCB - 1 Set

-

-

-

... More
VAV-06-GF-A 1500 450

1

-

-

... More
Providing & fixing MS Class ‘C’ (IS:1239) pipe with all type of fittings support arrangements jointing/welding materials and painting for diesel engine exhaust (including all fittings, clamps, steel supports and canopy at the termination point) of suitable dia for the engine as per manufacturer's specification. The pipe shall be provided with 12 mm thick super ceramic fibre rope. as per direction of Engineer in Charge.

-

-

-

... More
MAIN FEEDER PILLAR-2 : Incoming: 1 set of 400A,4-Pole, MCCB, 25 KA microprocessor based controlled with overload, short circuit and earth fault protection, 1 set of 400/5A CTs of 15VA burden, accuracy class - 0.5 for metering and class 5P10 protection with digital multifuntion meter along with 1set of R, Y, B, phase indicating lights (LED Type) with 2A, SP MCB, 10KA Outgoing : 63A 4P MCB, 10KA - 8 Nos, 32A 4P MCB, 10KA - 13 Nos. Shop drawings shall be in the scope of bidder.

2

-

-

... More
Providing and fixing white glazed vitreous china wash basins oval shaped under counter without C.P. pillar tap/Mixer, but with C.P. brass waste 32mm C.P. bottle trap and unions and sealing of joints between wash basins and counter slabs around the wash basins with Silicone rubber cement of approved make of matching colour all complete including cutting and making good the walls and floors where required as per direction of Engineer In Change. Hindware Wash basin ZEN Cat. No. 10049 (under counter) oval shape (560mm x 450mm) or approved equivalent make without CP pillar tap.

401

-

-

... More
2 no. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be corrosion resistant epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the center of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and, an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. 300 mm Finished Floor Height (FFH)

98

-

-

... More
3.5 C x 70 sq mm A2XFY cable

32

-

-

... More
Width Height Length

-

-

-

... More
100 mm dia drain pipe

48

-

-

... More
(ii) 350 10

1

-

-

... More
For 100mm dia Pipe

1754

-

-

... More
Bend 87.50. (iii) 160 mm diameter.

624

-

-

... More
SITC of StSt 316 grade clamp to terminate the load on earth electrode.

-

-

-

... More
1 Set Breaker ON / OFF / TRIP indicating lights with control MCB’s.

-

-

-

... More
On line 2 KVA UPS for PLC & CPU ( 30min Back up time.)

-

-

-

... More
Supply, Installation, Testing and Commissioning of LED Recessed Downlighter with pressure die cast housing. Nominal system lumen output of 1500 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a CCT 5700k or 6500k, CRI 80, PF 0.95, an operating Voltage Range of 220V- 240V, Standard Deviation Colour Matching (SDCM) =3 to =5. The luminaire shall meet IP20 rating with THD10% and PF 0.9. The luminaire housing should made of pressure die cast aluminium . The total Power Consumption should be within 12W to 16W (including driver). Similar to Philips Make GREENPERFORM SLEEK "DN 394B LED16S-6500 PSU WH" or eqiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification Required: LM 79 & LM 80 .Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

529

-

-

... More
(xvi) AH-1F-01 18 15300 4

1

-

-

... More
(viii) HRU-1F-03- 1900 CMH Ceiling Suspended

1

-

-

... More
SITC of Poly Plastic Pit Cover.

-

-

-

... More
f) 250 mm dia

32

-

-

... More
Note- License of all software with keys shall be submitted to client after commissioning of system

-

-

-

... More
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

14148

-

-

... More
ACSDB 05AHU ROOM : Supply, installation, testing and commissioning of following distribution boards totally enclosed compartmentalized, cubicle floor mounted, indoor type IP:42, factory fabricated with 2 mm thick sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply suitable for 25 KA as per specifications and drawings. All Air Circuit Breakers shall be provided with Micro processor based Earth fault, short circuit and over current releases. Moulded case circuit Breakers shall be microprocessor based electronic trip. Fault level for all ACB/MCCB and bus bar shall be 25 KA, all the motor feeder shall be type-2 coordinated. ICU shall be equal to ICS=100% . As Direction of E/C

2

-

-

... More
VAV-02-1F-G 4120 1236

1

-

-

... More
1 No. microprocessor controlled numerical relay with O/L, E/F and S/C protection.

-

-

-

... More
Marble panelling :-Providing & fixing Marble at wall 18 mm thick Italian Marble stone in Tile form as per sizes in the Drawing on 12 mm thick Ply board as Wall Cladding. The Ply board will be fixed with necessary Aluminium section on interior wall /Partition wall The work is inclusive of marble, plyboard, adhesive & framework all material and Labour charges all complete as per direction of Engineer in Incharge .

141

-

-

... More
SITC of Side Wall Clamp for 1.5mtr., 2 mtr., 2.5mtr. & 3 mtr., air terminal,according to IS/IEC 62305 as per direction of Engineer-in-charge

428

-

-

... More
Testing, Commissioning & Handing Over

-

-

-

... More
(ii) HRU-GF-01- 1800 CMH Floor Mounted

1

-

-

... More
Supplying, installing, testing and commissioning of CONFERENCE BUS CABLE 3M to be supplied from same OEM as Conference System as per directed by Engineer in Charge

12

-

-

... More
1 No. 40 Amps TP MCCB,50 KA, Thermomagnetic Protection controlled.

-

-

-

... More
300 mm dia. R.C.C. pipe.

1620

-

-

... More
For VIP:- Providing & fixing High grade Door Handle suitable for Mortise lock Left & Right operation of approved design & finish for Flush Wooden Door complete in all respect as per direction of Engineer in Charge.Material SS304 & SS finish.

367

-

-

... More
Supply, Installation, Testing and Commissioning of LED Surface mounted Luminaire with a nomial system lumen output of 2900(±5%) lumens and a minimum system efficacy of 90lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a CCT 5700k or 6500k, CRI 80, PF 0.95, an operating Voltage Range of 220V- 240V, Standard Deviation Colour Matching (SDCM) =3 to =5. . The luminaire shall meet IP20 rating with THD20% and PF 0.9. The total Power Consumption should be within 30W to 36W(including driver). Similar to Philips Make SmartBright Surface "SM270 LED30 6500 PSU OD GR" or eqiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification Required: LM 79 & LM 80 . Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

814

-

-

... More
Incomer

-

-

-

... More
Supplying, installation, testing & commisioning of following capacity Plug In/ Tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB (but without MCCB) complete etc. as required

-

-

-

... More
VAV-02-3F-A 4385 1316

1

-

-

... More
VAV-01-GF-D 3380 1014

1

-

-

... More
50 mm nominal bore.

20

-

-

... More
PMDB-SF (POWER MAIN DISTRIBUTION BOARD) ( SECOND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 1 as per direction of Engineer-in-charge

2

-

-

... More
(xxx) AH-2F-06* 17 14550 4

1

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.

-

-

-

... More
(xxii) AH-1F-07 22 19500 4

1

-

-

... More
All ACB & MCCB shall have Ics = 100% Icu

-

-

-

... More
Providing and fixing following rating and breaking capacity and pole MCCB with Microprocessor release in existing Tap Off Box including drilling holes in cubicle panel, making connections, etc. as required as per direction of Engineer-in-charge.

-

-

-

... More
d. Liabilities, obligations and risks arising out of Conditions of Contract.

-

-

-

... More
Armoured 2 Core x 1.5 sq mm FRLS Unscreened Cable as per directed by Engineer in Charge

400

-

-

... More
VAV-04-3F-B 1645 494

1

-

-

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required. (This device will be connected with flow switch)

140

-

-

... More
a.) Analog Extensions: 3408 lines with CLIP Facility on both DTMF as well as FSK.

-

-

-

... More
Bus Bar

-

-

-

... More
VAV-06-2F-A 2865 860

1

-

-

... More
o) Intrude in emergency call,

-

-

-

... More
Chemical with Anchor rod M20X240-260

4

-

-

... More
1 no. 100A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Fan should be AMCA certified for air and sound performance.

-

-

-

... More
Operator Workstation with CPU consist of i-7 with 3.5 Ghz speed, Min 8 GB RAM, Min 4 GB graphic card, 64 bit, 1 TB Hard Disk, DVD Writer 52X, Multimedia, Heat sink for integrated graphics, modem as per specifications.Colour Monitor SVGA - 22 “ Mouse & Key Board.Windows latest available operating system , Licenced Anti-Virus Software and laser printer suitable for ' A-4' size. The above mentioned requirements is minimum. The exact requirement shall be to suit the vendor requirement and will include all latest softwares

-

-

-

... More
Supply, Installation, Testing & Commissioning of Video Extender It should Extends the distance between HDMI source and HDMI display It should Implements HD Base T - Lite extension technology using only one Cat 5 cable to connect the transmitter and receiver. It should be HDMI (3D, Deep Color, 4kx2k); HDCP Compatible. It should support Long distance transmission - up to 70m. It should Supports resolutions of up to Ultra HD 4kx2k and 1080p Full HD. It should selects the optimum EDID settings for smooth power-up and highest quality display. It should Supports up to 340MHz bandwidth for high performance video. It should Supports Dolby True HD and DTS HD Master Audio. It should have Max. Data Rate 10.2 Gbps (3.4 Gbps Per Lane). It should support Max. Resolutions / Distance Up to Up to 4K@35m (Cat 5e/6) / 40m (Cat 6a/Cat6); 1080p@60m (Cat 5e/6) / 70m (Cat 6a/ Cat6). It should support Operating Temperature 0 - 50°C. It should have support Temperature -20 - 60°C.It should have support 0 - 80% RH, Non-Condensing as per directed by Engineer in Charge

1

-

-

... More
Lot - Accumulator, liquid and gas shut-off valves and solenoid valves/modulation valve with fittings to interconnect compressor, condenser and evaporator coils.

-

-

-

... More
c) 100 mm x 80 mm dia M.S reducing tee

12

-

-

... More
LMDB-SF (LIGHTING MAIN DISTRIBUTION BOARD) ( SECOND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 1 as per direction of Engineer-in-charge.

2

-

-

... More
Supply, Installation, Testing & Commissioning of pre-polarized condenser gooseneck microphone with base and on/off switch with logic control, an overall length of minimum 450 mm and with XLR3M-type connector at its base, which shall offer radio frequency interference (RFI) shielding against intermodulation from wireless equipment or devices, cardioid microphone capsule with uniform 120° angle of acceptance (-3dB) or better, frequency response of 50 Hz to 20,000 Hz or better and sound input levels handling capability of minimum 130 dBspl, nominal equivalent noise level of 26 Dba or better and output shall be low impedance balanced (100 ohms) with current consumption shall be 3 mA or better as per directed by Engineer in Incharge..

1

-

-

... More
Supply, Installation, Testing & Commissioning of LC- LC Patch Cord SM 2 mtr as per Specifications as directed by Engineer in Charge

204

-

-

... More
(i) 0-2000 Ammeter with Ammeter selector switch and 2000/5 C.T.s -1 Set

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size). (For Levelling Course for Toilet)

604

-

-

... More
Incoming

-

-

-

... More
Supply, Installing, testing and commissioning of 24-port data, 4 x 10G  with with License with 5 year warranty as per directed by Engineer in Charge

318

-

-

... More
Supply,installation,testing and commissioning of Ball valves of PN 16 Rating with insulation. All other parameters as per the technical specifications given in the tender. As Direction of E/C

-

-

-

... More
Incoming

-

-

-

... More
(c) 32 mm nominal bore.

2

-

-

... More
(iii) 16 A TP MPCB - 06 No.

-

-

-

... More
(b) ON / OFF / TRIP Indicating Lights with control fuses – 1 Set

-

-

-

... More
Providing and fixing square mouth UPVC gully trap heavy duty preparing mouth opening of 150mmx150mm complete with 150mmx150mm CI grating and brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design as directed by Engineer in Charge: 110 x 110 mm size P type . With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

154

-

-

... More
Design, Fabricate, Supply & Fixing Framework of Stainless Steel, Grade 304 tubular/hollow section with necessary arrangement of fixing the Signage Board of required sizes & Fixing the arrangement with Base plate of Required Size in The Ground with necessary earthwork in cutting & cover with PCC(1:1.5:3) cutting, welding etc. complete in all respect as per direction of Engineer In Change. (For out side fixing in the Ground and For Inside only Base Plate)

1000

-

-

... More
For Matt Finish of Sizes 800mmX800mm .

8168

-

-

... More
VAV-01-3F-C 5115 1535

1

-

-

... More
1 no. 100A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

11123.98

-

-

... More
LIFT NOTE 1:- Comprehensive maintenance after one year of defect liability period inclusive of periodic servicing, prompt attention to client complaint, prompt rectification of all malfunctions and equipment failures, replacement of defective equipment / parts, replacement of light fittings, lubrication including lubricants, maintaining correct alignment and levelling of cars and ensuring smooth running, starts and stops etc. all complete to the client satisfaction shall be done. For every 1(one) hour of delay in attending for a fault after allowing for 4(four) hours from the time a complaint has been lodged, will attract penalty. NOTE 2.:- All statutory approvals/Liecence from commencement to commissioning of lifts shall be obtained by the Contractor from the Inspector of Lifts and / or other authorities with free of cost.

-

-

-

... More
Door Switch - 6A - 2 No.

-

-

-

... More
VAV-04-1F-H 1070 321

1

-

-

... More
Bus Bar

-

-

-

... More
VAV-07-3F-H 2285 686

1

-

-

... More
(iii) 40 A 4P MCCB - 03 No.

-

-

-

... More
Solid State Alarm 24v DC - 1 No.

-

-

-

... More
Incoming

-

-

-

... More
Lacquered Glass:-Supplying & fixing 6mm Lacquerd white glass of approved make fixed in interior wall on specified area as per drawing complete in all respect as per direction of Engineer in Incharge at any level.

52

-

-

... More
4 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(xvi) VFDs in suitable enclosure shall be installed near the equipments for motors of following ratings:-

-

-

-

... More
80mm dia

40

-

-

... More
c) 600 mm dia. R.C.C. NP3 pipe

20

-

-

... More
SITC of StSt,Conductor holder for fixing of round conductors with slotted cleat, fixed conductor leading.Premounted with plastic base,as specified in drawing and andconfirming to IS/IEC 62305 as per direction of Engineer-in-charge.

4600

-

-

... More
(xxx) AH-3F-02* 34 29350 4

1

-

-

... More
Providing and fixing locakable type remote ON/OFF push buttons in suitable MS enclosure including mouting arrangement, etc. complete as required and as per specifications. As Direction of E/C

186

-

-

... More
Outgoing

-

-

-

... More
Chemical with Anchor rod M24X300

4

-

-

... More
Third party BMS Compatibility: Software required

-

-

-

... More
3 Sets of 4000/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
VAV-06-3F-B 3325 998

1

-

-

... More
(a) 80 mm nominal bore.

274

-

-

... More
Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.

20

-

-

... More
32 mm dia

4006.5

-

-

... More
Note: All metering current transformers shall be Class 0.5, 05 VA, cast resin type.

-

-

-

... More
VAV-01-3F-C 2140 642

1

-

-

... More
(c) ON/OFF push button with control fuses – 1 Set

-

-

-

... More
VAV-08-1F-B 3880 1164

1

-

-

... More
(d) R, Y, B phase indicating LED light with 2A MCB - 1 set

-

-

-

... More
VAV-05-1F-C 3445 1034

1

-

-

... More
Supplying & fixing Floor Spring weight upto 80kg with necessary fixture for Aluminium Door Shutter complete in all respect.

64

-

-

... More
1set of 3 nos PT 11kV/110V/Rt3/110V/Rt3, Cl-0.5/3P, 100VA

-

-

-

... More
DDC- 34

2

-

-

... More
VAV-03-1F-E 1165 350

1

-

-

... More
(iv) 19200

1

-

-

... More
(x) 0-63 A Ammeter with Ammeter selector switch & 63/5 C.T.s - 02 Sets

-

-

-

... More
25 mm dia

26264.61

-

-

... More
1 Set of 3200A 3P ACBs 50 KA (EDO) microprocessor controlled with overload, short circuit having :

-

-

-

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

202

-

-

... More
(v) 400 mm dia

126

-

-

... More
Providing & fixing 25mm dia semicircular button shape pointed Brass Knob of approved Design as façade design for panelled Door shutter all complete as per drawing and direction of Engineer-in-charge.

1468

-

-

... More
LIFT SIGNAGE

72

-

-

... More
Providing & fixing of approved Make H-TYPE PULL Handle hollow Brass material & Brass antique finish 1200mm overall lengthx40 mm dia of approved design & make with necessary nuts, screw etc. for Panelled Door shutter complete in all respect as per direction of Engineer-in-charge.

128

-

-

... More
Toilet Indicator Lock: Providing & Fixing Indicator Lock Body With Strike Plate & Occupied Indicator Knob -Left & Right operation For FRP & Flush Door Shutter Material SS304 & SS finish as per direction of Engineer in Charge

496

-

-

... More
Supplying fixing and connection P17 tempra combined units with 250V,32A,2P+E interlocked switched socket and surface mounted box IP66 Legrand Cat no.056661 or equiv. (4 wheeler charging) as per directed by Engineer in Charge.

96

-

-

... More
(i) 0-300 Ammeter with Ammeter selector switch and 300/5 C.T.s -1 Set

-

-

-

... More
2 Sets of 1600/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Fire retardant paint:-Providing and applying two or more coat of fire retardant paint on cleaned steel surface with smooth finish at any level including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant as per direction of the Engineer In charge.

7496

-

-

... More
Bus Bar

-

-

-

... More
Supply, Installation, testing and commissioning, of central air cleaner/Filter air purification system that improves the indoor air quality through reducing harmful pollutants like particulate matter (PMx) minimum efficiency of 0.3 micron particulates has to be 93% or near to edge 11 HEPA class of multi circulating efficiency PM 2.5, allergens, pollen, bacteria, pathogens based on trap & kill technology, odor & VOC's etc. It should be a monobloc structured unit specifically designed for integration in Return Air path, to centrally capture and kill germs. It should have x4 working principles and it should be powder coated steel casing and should be self contained. The minimum life of central air cleaner unit should be more than 10 years without any consumable parts. A detailed selection chart as per each application zone shall be submitted for approval. Indian air pollution algorithm based intelligent maintenance system with inbuilt air flow sensing technology is must for all AHU for trouble free wiring connections. The central air cleaner must be equipped with ACF Granular Filtration Process for effective removal of odor & gases from the pollutant air. The contractor has to install these Filter in the AHU by the supplier only. The filter should have potential free contact/ NO-NC so that it can be taken on the BMS system. Max pressure drop should not exceed 6 mm WG. As Direction of E/C

-

-

-

... More
EARTHING (as per IS : 3043) Providing and fixing earth bus of 50 mm X 6 mm copper strip on surface for connections etc. as required. (For T/F And DG Neutral Earthing )

530

-

-

... More
900 mm width x 62.5 mm depth x 2.0 mm thickness

6

-

-

... More
Anti vibration mountings , Foundation for fan. Vibration isolator shall be selected/ designed in such a way that fan vibrarion should not transfer to the structural members . Power cables from panel to fans motor etc as required upto complete satisfaction of client/ Engineer incharge.

-

-

-

... More
Water flow rate – 2958 LPM

-

-

-

... More
PMDB-SF (POWER MAIN DISTRIBUTION BOARD) ( SECOND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 2 as per direction of Engineer-in-charge

2

-

-

... More
Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for ew work : 100 mm diameter pipe

160

-

-

... More
50 mm nominal outer dia .Pipes.

11

-

-

... More
(xxv) AH-2F-01 15 13500 4

1

-

-

... More
Cooling Tower Bleed Off Valve with Actuator - 1 No.

-

-

-

... More
2 core 1.0 mm², PVC insulated, multi stranned tinned annealed copper conductor cable - shielded.

-

-

-

... More
Providing and fixing 2/2 Way Pilot Operated Diaphragm type Solenoid Valve, screwed or flanged end,suitable for water supply as per site, of SS body (SS-304) to ASTM A 351 GR CF 8 & internals having weather proof coil enclosure & working pressure range (min. 0.7 Kg/cm2 & max 12 Kg/cm2 ) with coil of 220 Volt, AC suitable for horizontal installation, normally closed with all electro mechanical accessories including 2/2 way Y type strainer at inlet of solenoid valve, screwed ends, body & cover SS 304 to ASTM A 351 GR CF 8 with same working pressure as stated above, having diaphragm of nitrile rubber and 40 mm mesh size. along with automatic solenoid valve On-Off Controller Box with one number Float switch sensor for water tank level controller with five meter long control wire connecting to solenoid valve and exluding electrical supply wire connection to controller box and wire from controller box to solenoid valve, with opeating voltage of 220 AC suitable for vertical/horizontal installation in water tank as per site condition suitably connected to solenoid valve through control cable all inclusive with all electro mechanical accessories complete operational (Operation by SCADA system) all complete as required complete as per direction of Engineer-in-charge .

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No- 3 pin 5/6 A modular socket outlet and 2 No- 5/6 A modular switch, connections etc. as required.

284

-

-

... More
(iii) 21700

1

-

-

... More
1600 A, 415V, 4 strip, 50 KA, 50 Hz Aluminium Bus bar

-

-

-

... More
9. The unit rate for all local equipment or materials in Indian Rupees shall include cost of equipment and materials including all taxes and duties and also including forwarding, freight, insurance and transport into Contractor’s store at site, storage, installation, testing, balancing, commissioning and other works required.

-

-

-

... More
Extra for using salt and charcoal for G.I or Copper plate earth electrode as required.

186

-

-

... More
(a) 2000 A 4P ACB – 1 No.

-

-

-

... More
2 Core x 2.5 Sq.mm Cable

12

-

-

... More
FACADE LIGHTING : 1. Quantity may vary as per site conditions. 2. All special fixtures, equipments, accessories, light fixture, attachment etc. not specifically mentioned but are required for safety & proper functioning and efficiency of system shall be included in the offer. 3. Power Supply - A source of electrical operating power, including the circuits and terminals connecting it to the dependent system components are in the scope of bidder. 4. The bidders shall include the cost of system integration, software programming, system testing, commissioning, mock-up, training to departmental engineers of the operation of all system components and the entire system,. The cost of system integration shall be included proportionally in the rates of items indicated in the bill of quantities as per directed by Engineer in Charge.

-

-

-

... More
16mm dia rebar at 400 mm depth

4

-

-

... More
Bus Bar

-

-

-

... More
(i) 75 mm diameter.

4

-

-

... More
Supplying, installing, testing and commissioning of POP UP BOX: It should be a Hydraulic pop up box; It should have a VGA ,HDMI,AUDIO,USB,LAN X 2 Connectors; It should have 2 Un - switched AC Power 220V, 13 Amp Outlet, It should have an on/off Switch with indicator as per directed by Engineer in Charge.

3

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:. 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. (Supply of Butt Hinge paid in separate item)

6462

-

-

... More
GLASS ROOF FOR UNDER PASS:- Supplying & fixing Floor lite glass of 31mm comprising of different thickness Lamineted together by highly tear proof polyvinyle butyral. Glass should be fixed with SS304 frameof suitable member as per drawing & design along with Silicon Bifil Shore-A-hinte 60-80 & minimum 30mm inside to the frame complete in all respect as per direction of the Engineer in charge.

180

-

-

... More
3 Sets of 4000 A 4P ACBs 65KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings along with mechanical and electrical interlocking arrangement with bus coupler.

-

-

-

... More
VAV-02-1F-C 2870 861

1

-

-

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.

-

-

-

... More
Supply Installation , Testing and Commissioning of a 4X4 Matrix Switcher • It Should Connects any of 4 HDMI sources to any of 4 HDMI displays It should support 4K resolutions up to UHD (3840 x 2160) and DCI (4096 x 2160) with refresh rates of 30 Hz (4:4:4) and 60 Hz (4:2:0) • It should have EDID settings for smooth power-up, high-quality display and use of the best video resolution across different screens • It should support Multiple Control Methods – system management via front-panel pushbuttons, IR remote and RS-232 control • Should support Dolby True HD and DTS HD Master audio • It should support Signaling rates up to 3.4 Gbits for flawless 4K output • It should support HDMI (3D, Deep Color, 4K) and should be HDCP 1.4 compatible • Should support ESD protection for HDMI • Should have Consumer Electronics Control (CEC) which allows interconnected HDMI devices to communicate and respond to a single remote control Should support HDMI cable lock for secure HDMI cable connections • Should have a Firmware which is upgradeable • It Should be Rack Mountable as per directed by Engineer in Incharge.

2

-

-

... More
(xi) 2340 15

2

-

-

... More
All MCCBs with Microprocessor release should have adjustable O/L, S/C & inbuilt E/F protections

-

-

-

... More
Outgoing

-

-

-

... More
VAV-06-3F-G 1360 408

1

-

-

... More
Supply, Installation, Testing, & Commisioning of Wire Braided Flexible Rubber Hose with Elbow and connectors complete assembly to Connect Novec 1230 Cylinder Assembly Discharge outlet with Discharge Pipe or Discharge Manifold. as per direction of Engineer in Charge.

86

-

-

... More
DDC- 44

2

-

-

... More
3.5 C x 35 sq mm A2XFY cable

1000

-

-

... More
Supply, Installation, Testing, & Commisioning of Discharge Nozzles to Discharge Novec 1230 Gas in the Hazard Area as hydraulic calculation and flow rate required in 180 Deg/360 Deg Discharge Pattern. as per direction of Engineer in Charge.

166

-

-

... More
4 Strip aluminium bus bar of 150 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
DDC- 16

2

-

-

... More
Sheet metal Ducting & Accessories :-Supply, installation, testing, balancing and commissioning of factory fabricated GSS Rectangular/Round ducting of following thickness including necessary supports, hangers, nut bolts, gaskets, splitter dampers, vanes, canvas connections etc. complete . as per SMACNA standard along with all accessories and fitings. . The prices shall also include necessary galvanized duct supports consisting of fully threaded galvanized rods, galvanized angles or double-L bottom brackets, nuts, washers and anchor bolts (Hilti make) generally conforming to SMACNA/IS standards. All other parameters as per the technical specification given in the tender. As Direction of E/C

-

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work80 mm dia nominal bore (Note:- Pumping for work from discharge of submersible pump onwards:)

21

-

-

... More
(a) 80 mm nominal bore.

4512

-

-

... More
(v) 16700

1

-

-

... More
(ix) 0-40 A Ammeter with ammeter selector switch & 40/5 CT's - 4 Sets.

-

-

-

... More
Outgoing

-

-

-

... More
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.

-

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
(e) 50 mm nominal bore.

2

-

-

... More
(iv) 1.0 mm

5353

-

-

... More
ACSDB-05 (F) Supply, installation, testing and commissioning of following distribution boards totally enclosed compartmentalized, cubicle floor mounted, indoor type IP:42, factory fabricated with 2 mm thick sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply suitable for 25 KA as per specifications and drawings. All Air Circuit Breakers shall be provided with Micro processor based Earth fault, short circuit and over current releases. Moulded case circuit Breakers shall be microprocessor based electronic trip. Fault level for all ACB/MCCB and bus bar shall be 25 KA, all the motor feeder shall be type-2 coordinated. ICU shall be equal to ICS=100%. As Direction of E/C

2

-

-

... More
3 No. (2 W + 1 SB) Factory mounted Vertical Inline split coupled secondary chilled water pump centrifugal pumps set along with suction guides and complete with suitable HP, IE2 TEFC induction motor with class ‘F’ insulation, IP -55 protection, operating on 415±10% volts, 3 phase, 50 cycles AC supply for each pump with IP-55 motor mounted VFD of suitable rating.

-

-

-

... More
(iii) HRU-GF-01- 1800 CMH Floor Mounted

1

-

-

... More
(i) 230 mm dia ≤ 1400 RPM

25

-

-

... More
(viii) 40 mm dia

24

-

-

... More
Shunt trip coil. - 2 Sets

-

-

-

... More
(ii) 23900

1

-

-

... More
VAV-03/04-1F-A 1245 374

2

-

-

... More
Supply, Installation, Testing, & Commisioning of Primary pressure operated slave control head complete kit with pneumatic actuating valve operated pneumatically from the master cylinder discharge pressure, Flexible interconnincting hose. Complete with cylinder supervisory switch. as per direction of Engineer in Charge.

38

-

-

... More
2 Sets of 2000/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
(a) 20 mm and weight not less than 400 gms

4

-

-

... More
40mm nominal bore

80

-

-

... More
VAV-07-1F-C 5080 1524

1

-

-

... More
SECONDARY CHILLED WATER VARIABLE SPEED PUMPING SYSTEM (2w+1s) Supply, installation, testing and commissioning of secondary chilled water variable speed pumping system comprising the following and complete as per specifications As Direction of E/C

3

-

-

... More
Wall light : LED 25W(±10%) Wall light Luminaire with Polycarbonate housing and frame, it comprises of Opal polycarbonate diffuser to minimize glare. Color temp.3000K, Color Rendering Index ≥70, Total Harmonic Distortion 15%, Driver Efficiency 85%,IP 65, PF 0.95, Surge Protection 4KV.Luminaire Performance: IS:10322 (Part 5/Sec 3) & IEC 60598-1, IEC 60529 & Complies IEC 62384, Certification: LM 79 & LM 80 Certificates. Min Delivered Lumens: 777(±10%) lumen, Standard Deviation Colour Matching (SDCM) 4, an operating Voltage Range of 180 - 240 V,similar to Bajaj Cat. No. BLWSP 25W LED or equiv. Sample luminaire and paint shall be got approved by Engineer-incharge / consultant.

40

-

-

... More
Supply,installation,testing and commissioning of Expansion Bellows PN 16 rating . All other parameters as per the technical specifications given in the tender. As Direction of E/C

-

-

-

... More
65mm diameter UPVC. pipe

330

-

-

... More
Outgoing

-

-

-

... More
110 mm inlet and 110 mm outlet

1490

-

-

... More
(ii) 20 mm Dia

4

-

-

... More
Bus Bar

-

-

-

... More
LT CAPACITOR PANELS as per directed by Engineeer in Charge.

-

-

-

... More
1 Set of R, Y, B phase indicating light (LED type) with 2A , SP MCB, 10KA

-

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :

-

-

-

... More
VAV-09-GF-D 1894 568

1

-

-

... More
Providing, fixing, Chlorinated polyvinyl chloride (CPVC) pipes SDR 11/sch40 , having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1m spacing . This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work - Exposed on Wall

-

-

-

... More
8 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
SITC of clamp for (500 mm) air terminal,confirming to EN 62561 and according to IS/IEC 62305 as per direction of Engineer-in-charge

160

-

-

... More
2 Sets of 630 A 4P MCCBs 50 KA miroroprocessor based controlled with overload, short circuit and earth fault protections.

-

-

-

... More
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.

1300

-

-

... More
Incomer

-

-

-

... More
SITC of Air Terminal 3 mtr. side wall ,confirming to EN 62561 and according to IS/IEC 62305 as per direction of Engineer-in-charge

76

-

-

... More
Outgoing

-

-

-

... More
7. The Contractor shall procure and bring Materials/Equipment to the site only on the basis of drawings approved for construction and shop drawings and not on the basis of Schedule of Quantities which are approximate only. This also applies to the Contractor’s requisition for Owner supplied materials.

-

-

-

... More
Supplying, fitting and fixing Puddle collar in RCC walls or floors etc. assembly/sleeves consisting of MS pipes(Heavy type) conforming to IS : 1239 and IS : 3589 having required shell thickness, both ends flanged drilled to IS specification and one end matching blank flange(welded to pipe) with nuts, bolts, washers etc.and MS collar of minimum 6 mm thickness of specified size welded all round the pipe complete including three coats of bituminous paint on concealed portion and a coat of zinc oxide primer and two coats of synthetic enamel paint of approved shade on the exposed portion of the puddle collars as per direction of Engineer-in-charge. Upto 250 mm dia (both end flanged or threaded).

2200

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
Over Current relay

-

-

-

... More
All MCCB outgoings spare wired contacts for ON/OFF and Trip shall be provided for SCADA / BMS communication.

-

-

-

... More
ACSDB 04 AHU ROOM : Supply, installation, testing and commissioning of following distribution boards totally enclosed compartmentalized, cubicle floor mounted, indoor type IP:42, factory fabricated with 2 mm thick sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply suitable for 25 KA as per specifications and drawings. All Air Circuit Breakers shall be provided with Micro processor based Earth fault, short circuit and over current releases. Moulded case circuit Breakers shall be microprocessor based electronic trip. Fault level for all ACB/MCCB and bus bar shall be 25 KA, all the motor feeder shall be type-2 coordinated. ICU shall be equal to ICS=100% . As Direction of E/C

2

-

-

... More
(iii) 35600

1

-

-

... More
VAV-07-2F-F 4470 1341

1

-

-

... More
Outgoing

-

-

-

... More
3.5 C x 120 sq mm A2XFY cable (45mm)

32

-

-

... More
(xiii) HRU-2F-08- 2500 CMH Floor Mounted

1

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

1000

-

-

... More
Supply, Installation, Testing & Commissioning of Bulk cables and connectors with LAN I/O ports for VC and requisite UPS power point for rack as per directed by Engineer in Incharge.

2

-

-

... More
Constructing brick masonry road gully chamber/catch pit 45x45x77.5 cm with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) with pre-cast R.C.C vertical grating complete as per standard design:with common burnt clay F.P.S (non modular) bricks of class designation 7.5

154

-

-

... More
Providing & Laying epoxy bonding agent as per manufacturer specification before laying New concrete over old Concrete complete in all respect as per direction of the Engineer in charge.

6000

-

-

... More
6 Nos, 250 Amps TP MCCB, 50 KA, Thermomagnetic Protection controlled.

-

-

-

... More
Supply of 13.56MHz PVC Smart Cards for Employees & Security Personnel & House-keeping Staffs as directed by Engineer in Charge.

2

-

-

... More
Outgoing

-

-

-

... More
PLC HARDWARE (Synchronizing Equipment)

-

-

-

... More
Armoured Communication cable: FRLS Communication Cable 2 Twisted pair x 1.0 mm2 Multistranded Screened Communication cable with Al Mylar Tape and 0.5 mm2 Drain wire as per requirment by System as per directed by Engineer in Charge.

8000

-

-

... More
Type of Compressor: Twin Rotary Screw Compressor

-

-

-

... More
(g) 65 mm nominal bore.

2629

-

-

... More
2 Core x 2.5 Sq.mm Cable

300

-

-

... More
(ix) 0-40 A Ammeter with Ammeter selector switch & 40/5 C.T.s - 10 Sets

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Extra for Labour charges for laying conc. :1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) above plinth at any Level as per direction of the Engineer-in-charge.

604

-

-

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire [Building Switch Board & Lighting Circuiting]

104490

-

-

... More
SITC Of earthing Bar made of 16 SWG wall mounted MS Enclosure (with Cover and Lock & Key arrangement) of size 450x200x75 mm deep providing 3 nos. insulated supports, 50x6 mm thick Copper strip (Tin plated) with suitable holes to fix 2 nos. incoming 32x6 mm strips and 6 nos. outgoing earth strips of size 25x6 mm. as required. as per direction of Engineer-in-charge.

108

-

-

... More
Analog Phone as per directed by Engineer in Charge

6976

-

-

... More
A set of Sump pumps (Non-clogging type) having discharge capacity of each pump approx.10 cum/hr at 15 m. pumping head (1 working, 1 standby) Suction from sumps in in Lower ground floor, delivery to surface drain at ground level. Including MCC and allied works

22

-

-

... More
DDC- 11

2

-

-

... More
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required

172

-

-

... More
PMDB-GF (POWER MAIN DISTRIBUTION BOARD) ( GROUND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 2 as per direction of Engineer-in-charge

2

-

-

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

-

-

-

... More
15mm dia

592

-

-

... More
VAV-04-1F-D 3840 1152

1

-

-

... More
(a) 15 mm nominal bore.

1574

-

-

... More
VAV-03-2F-A 2490 747

1

-

-

... More
4x125 kVAr LT power capacitor banks with 4 No 100 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
(ii) 150 mm width X 50 mm depth X 1.6 mm thickness

200

-

-

... More
Low lub. Oil trip indication

-

-

-

... More
4 Strip aluminium bus bar of 100 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
VAV-04-2F-G 2690 807

1

-

-

... More
1 Set 63 Amps 3 phase 4 wire AL. Bus-Bar

-

-

-

... More
(ii)25 Pascal

30

-

-

... More
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.

-

-

-

... More
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

54044

-

-

... More
Supply, Installation, Testing & Commissioning of 24 U Rack which should have 4 nos. castors. All castors should be without any brake or any other locking mechanism Front door – Front Vented Glass door should be provided with 2 locks for the security purpose. This door should have provision to get mounted on Right or Left side of the rack front. This means that it should be possible to change the door configuration from Left to Right at site. It should also be possible to open this door by 180 Degrees to ensure proper approach to front of rack Rear door should be completely perforated to facilitate the air circulation at the maximum without offering any resistance to the same. Ideally, it should be possible to remove it easily and should have 2 locks for the security purpose. Rear doors should have provision to mount fan trays. Side Panels should be easily removable type along with the provision for locking. Ideally, the panels should have latching arrangement to facilitate easy removal and putting back the panel along with locks for the security purpose Height - The Rack should Provide 24U Usable Space Depth – The rack should be at least 600mmD. Usable Depth should be not less than 500mm Load carrying capacity of rack should be 500 Kg Mounting rails (for Standard 19" mounting) should be made up of steel. (Minimum 2.0mm thickness) and should be of Multi-fold design for enhanced loading capacity and rigidity. It should have unique U Marking along with U locator notch. U Number Markings should be clearly visible even after mounting of the equipment Two Numbers 1U Cable Manager should be provided along with Metal Loops for Cable Dressing as per directed by Engineer in Incharge..

2

-

-

... More
20mm nominal outer dia. Pipes

3786

-

-

... More
NPLV- Minimum 9.0

-

-

-

... More
150 mm dia

36

-

-

... More
Supplying, installing, testing and commissioning of POP UP BOX: It should be a Hydraulic pop up box; It should have a VGA ,HDMI,AUDIO,USB,LAN X 2 Connectors; It should have 2 Un - switched AC Power 220V, 13 Amp Outlet, It should have an on/off Switch with indicator as per directed by Engineer in Charge.

3

-

-

... More
6. Any error in totaling in the amount column and in carrying forward total shall be corrected. Any error, in description or in quantity, omission of items from this Schedule shall not vitiate this Contract but shall be corrected and deemed to be variation required by the Services Consultant/Project Manager.

-

-

-

... More
VAV-05-3F-A 4015 1205

1

-

-

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for sluice valve, with C. I. surface box 100 mm top diameter, 160 mm bottom diameter, 180 mm deep inside with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement providing and fixing painted CI frame and cover of size 600X600 weighing not less than 23 Kgs with locking arrangement fixing the frame in CC 1:2:4 including form work, curing, etc complete as per standard design as per direction of Engineer-in-charge: With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

8

-

-

... More
Floor Finish:- With High quality Granite in Pattern (Material paid in separate item, unless mentioned otherwise.)

-

-

-

... More
For Matt Finish of Sizes 600mmX600mm .

416

-

-

... More
Supply, Installing, testing and commissioning of  Firewall bundle with Threat Defense Chss,Subs HA Bundle with 5 year warranty as per directed by Engineer in Charge

2

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
LMDB-SF (LIGHTING MAIN DISTRIBUTION BOARD) ( SECOND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 2 as per direction of Engineer-in-charge

2

-

-

... More
Supply, Installation, Testing & Commissioning of Patch Panel Cat-6A, UTP, Meets EIA/TIA 568-C.2, UL Listed, as per Specifications as directed by Engineer in Charge

44

-

-

... More
(iii) 300 mm dia

1393

-

-

... More
Differential Pressure Switch, Liquid

56

-

-

... More
(iv) AH-LGF-05 10 9200 4

1

-

-

... More
VAV-05-1F-E 2625 788

1

-

-

... More
(iii) R,Y,B indication LED light with 2A MCB - 1 Set

-

-

-

... More
DDC- 28

2

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
(i) Dia 350mm (8.0 mm thick)

366

-

-

... More
VAV-06-2F-B 2880 864

1

-

-

... More
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

12438

-

-

... More
(i) 300 A, 415V, 3ph, 4 wire Aluminium busbar

-

-

-

... More
Cornices and mouldings

716

-

-

... More
Supplying, fitting and fixing C.P. Angular stop cock of Jaquar cat no. CQT-CHR-23053 or approved make and brand tested to 21 kg per sq. cm for VIP & VVIP areas as per direction of Engineer in Charge.

384

-

-

... More
4 Set of 63/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
1 nos. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Supplying and fixing Dash fastener for aluminium Door & Window complete in all respect and instructions of the Engineer in charge..

44167

-

-

... More
SLP-05 (SUB LIFT PANEL-05 ) ( ROOF - EAST & WEST BLOCK) as per direction of Engineer-in-charge.

2

-

-

... More
2 Sets of 630 A 4P MCCBs 50 KA miroroprocessor based controlled with overload, short circuit and earth fault protections.

-

-

-

... More
6 Sets of R, Y, B Phase indicating lights (LED Type) with 2A, SP MCB, 10KA.

-

-

-

... More
1 No. Surge Suppressor Type-2 as per specification

-

-

-

... More
Providing , testing & retain 100 mm dia PAD LOCK Brass Body,7 Brass Levers,3 Brass Keys & Hardened Shackle as per direction of Engineer-in-charge.

64

-

-

... More
Supply,installation,testing and commissioning of balancing valve of rating PN16 with pressure test cocks only in SS -410 Stem, EN-3 Disc and EPDM sealing disc, complete with insulation & all accessories and all other parameters as per the technical specifications given in the tender.

-

-

-

... More
FACADE LIGHTING : 1. Quantity may vary as per site conditions. 2. All special fixtures, equipments, accessories, light fixture, attachment etc. not specifically mentioned but are required for safety & proper functioning and efficiency of system shall be included in the offer. 3. Power Supply - A source of electrical operating power, including the circuits and terminals connecting it to the dependent system components are in the scope of bidder. 4. The bidders shall include the cost of system integration, software programming, system testing, commissioning, mock-up, training to departmental engineers of the operation of all system components and the entire system,. The cost of system integration shall be included proportionally in the rates of items indicated in the bill of quantities.

-

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.(Civil related PHE Items)

15400

-

-

... More
Incoming

-

-

-

... More
150 mm dia. R.C.C. pipe.

9376

-

-

... More
Supply, Installation, Testing & Commissioning of 5.0M GI Pole for Automatic Number Plate Recognition (ANPR) as per technical specification. Civil works for Pole shall be in the scope of bidder. :- 1no.

-

-

-

... More
(i) 50 mm dia

28

-

-

... More
3 No. (2 W + 1 SB) Factory mounted Vertical Inline Split Coupled Condenser water centrifugal pumps set along with suction guides and complete with suitable HP, IE2 TEFC induction motor with class ‘F’ insulation , IP -55 protection, operating on 415±10% volts, 3 phase, 50 cycles AC supply for each pump.

-

-

-

... More
Clear opening of Gates / Doors : 1000 X 2100 (MM Wide X MM Height)

-

-

-

... More
(iii) 125mm dia

4

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
Fan should be AMCA certified for air and sound performance.

-

-

-

... More
Earth work in back filling the trench after laying different types and sizes of pipes with earth removed during excavation within initial lead and lift as per specification and direction of E/I

45548

-

-

... More
Providing and fixing standard firemans axe with heavy rubber handle as per directed by Engineer in Charge.

16

-

-

... More
(ix) AHU FAN SECTION ….. 24450 ….

1

-

-

... More
Supply, installation, testing, balancing and commissioning of powder coated extruded aluminium Exhaust air grilles of various sizes and complete as per specifications.

107

-

-

... More
(i) 150 mm nominal bore.

53.76

-

-

... More
Supply, Installation, Testing, & Commisioning of Novec 1230, CCOE Approved 40.0 Ltrs. Cylinder working at 34.5 bar pressure with Valve Assembly and arrangement for Supervisory Switch connection for monitoring cylinder pressure, a pressure gauge with a safety burst disc and safety cap. as per direction of Engineer in Charge.

2

-

-

... More
Providing & fixing Mortise Lock for Double Panelled Door shutter of approved make & design complete in all respect as per direction of Engineer-in-charge.

64

-

-

... More
(iii) 0. 8 mm

13983

-

-

... More
All ACB & MCCB shall have Ics = 100% Icu

-

-

-

... More
Incoming

-

-

-

... More
(ii) 0-500 V Voltmeter with Voltmeter selector switch and control fuses - 1 Set

-

-

-

... More
Supply, Installing, testing and commissioning of Wi fi Controller with 5 year warranty as per directed by Engineer in Charge Supply, Installing, testing and commissioning of Wi fi Controller License(Already bundled with Controller hardware) as per directed by Engineer in Charge

4

-

-

... More
Dumb bell with central bulb (180 mm wide, 8 mm thick)

20

-

-

... More
(xi) 0-10 A Ammeter with ammeter selector switch & 10/5 CT's - 11 Sets.

-

-

-

... More
Supply, Installation, Testing & Commissioning of 5 Mtrs HDMI Cable : Crystal-clear video up to 4K DCI (4096 x 2160 @ 30Hz), 4K UHD (3840 x 2160 @ 30Hz), and 1080p @ 60Hz signal HDMI Ethernet Channel functionality: additional dedicated data channel supports networking HDMI (3D, Deep Color, 4K) and HDCP 2.2 compatible Gold-plated connectors for reliable transmissions 5 mtrs in Length RoHS-compliant as per directed by Engineer in Incharge.

3

-

-

... More
Providing and fixing brass stop cock of approved quality

-

-

-

... More
3 Sets of 200/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Condenser Water Flow- 3690 LPM

-

-

-

... More
1 Set of 63A 4P MCBs, 10KA

-

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
IPLV - Minimum 9.5

-

-

-

... More
LMDB-3F (LIGHTING MAIN DISTRIBUTION BOARD) ( THIRD FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 2 as per direction of Engineer-in-charge

2

-

-

... More
b) 7.5 KW - 01 No.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Rack Mounted, Layer3, 28-port GbE Managed Fiber Switch with 4 SFP+ Uplink (Dual AC Power), 20 Nos. should be 1G SFP Module and 4 Nos. 10G Module, 1G Ports should be fully Loaded, full multicast support & full Layer 3 functionality, completely as per specifications as directed by Engineer in Charge.

2

-

-

... More
(vi) 0-16 A Ammeter with Ammeter selector switch & 16/5 C.T.s - 21 Sets

-

-

-

... More
(iv) 2210 CMH at SP at 15 mm WG

10

-

-

... More
SITC of Conductor holder for fixing of round conductors with slotted cleat, fixed conductor leading.Premounted with plastic base,as specified in drawing and andconfirming to IS/IEC 62305. Dehn Part No.274150 as per direction of Engineer-in-charge

7700

-

-

... More
Supply, Installation, Testing & Commissioning of 0.6 HDMI Cable: Crystal-clear video up to 4K DCI (4096 x 2160 @ 30Hz), 4K UHD (3840 x 2160 @ 30Hz), and 1080p @ 60Hz signal; HDMI Ethernet Channel functionality: additional dedicated data channel supports networking HDMI (3D, Deep Color, 4K) and HDCP 2.2 compatible; Gold-plated connectors for reliable transmissions; 0.6 mtrs in Length, RoHS-compliant as per directed by Engineer in Charge

2

-

-

... More
(xiii) 3.0c x 2.5 sqmm

1200

-

-

... More
In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile

1719

-

-

... More
(ii) 0-500 V Voltmeter with Voltmeter selector switch and control fuses - 1 Set

-

-

-

... More
50mm nominal bore

2

-

-

... More
50 mm dia

3821.972

-

-

... More
• Earthling with GI pipe as per IS : 3043, 1 lot

-

-

-

... More
Supply, Installation, Testing & Commissioning of wall mounted 55" Commercial Grade LED display. Mounting arragement with related accessiories and civil work shall be in the scope of bidder as directed by Engineer in Charge.

12

-

-

... More
Outgoing

-

-

-

... More
30800 CMH, Static pressure - 70 mm of H2O.

2

-

-

... More
Pilot Light Red 24V AC (Set ON) - LED type - 3 No.

-

-

-

... More
TAG No. Cooling Load (TR) Each Air Qty (CMH) Chilled Water Coil (Row)

-

-

-

... More
VAV-08-2F-B 2750 825

1

-

-

... More
Bus Bar

-

-

-

... More
VAV-03-1F-H 1185 356

1

-

-

... More
VAV-01-2F-F 3365 1010

1

-

-

... More
Auto-manual / test selector / switch - 2 Sets

-

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
(ii) 25840 CMH at SP at 20 mm WG

16

-

-

... More
Providing and fixing uPVC SCH 40 pipes as per ASTM D 1785 and fittings ASTM D 2466 as per specification with push fit socket & spigot joint system with cement solvent jointing system as per manufacturer specification in exposed condition suitable for Pump risers at depths including all necessary fittings, pipe length as per drawing and specification including hydraulic field testing and commissioning etc all complete as directed by Engineer in Charge.

-

-

-

... More
(vi) 765 +250 +935 15

28

-

-

... More
Supply, Installation of Cylinder Bracket for 80/120/150 ltr

88

-

-

... More
Suitable Digital Output Module - Minimum 16 CH .

-

-

-

... More
32mm dia

7

-

-

... More
(e) 50 mm and weight not less than 1.5 kg

12

-

-

... More
10 LB capacity Novec 1230 , DLP Assembly with automatic valve, push in connector for tube,10 LB Novec 1230 gas , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation. as per direction of Engineer in Charge.

36

-

-

... More
Extra for addition of synthetic Polyester triangular fibre of length 12mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement concrete/RCC/Flooring/water retaining structures by using Per Bag of 125gms of synthetic Polyester triangular fibre for 50 Kg cement used 50 Kg of as per directions of Engineer-in-Charge. (Note:-FOR DOME CONC. only)

3224

-

-

... More
(ii) 1800 550 900

1

-

-

... More
For 100mm dia Pipe Class K-9 pipes.

9638

-

-

... More
LIFT NO.29 Single Car (SERVICE LIFT) as per directed by Engineeer in Charge.

-

-

-

... More
Bus Bar

-

-

-

... More
1 sets of 3 no CTs 250/5A of 15 VA burden and accuracy class - 0.5 for metering and class 5P20 for protection.

-

-

-

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

305

-

-

... More
DOOR SHUTTER:- Designing ,Providing, fabricate and fixing wood for paneled and glazed shutters for doors, , excluding paneling which will be paid for separately, all complete as per direction of Engineer-in-charge. Second class teak wood 50 mm thick shutters. (SHOP DRAWING SHOULD BE APPROVED BEFORE EXECUTION OF THE WORK)

186

-

-

... More
2 No. Differential pressure sensors / transmitters not required in case of sensor less.

-

-

-

... More
Water flow rate – 2730 LPM

-

-

-

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable.

368

-

-

... More
(C) 150 mm nominal bore.

5376

-

-

... More
35mm thick Metal Door SIZE 2000MM(W)X2100MM(H) Double Shutter Including MS Hardware.(6nos. 100mmx75mmx3mm MS Butt Hinge, 4nos.250mm Long D-Type MS Handle Fabricated MS 20mm dia ROD, 1 no.250mm Aldrop Finished painted as per approved colour) complete in all respect.

39

-

-

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick

10748

-

-

... More
VAV-03-2F-G 2450 735

1

-

-

... More
UMDB-TF UPS MAIN DISTRIBUTION BOARD) ( THIRD FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 2 as per direction of Engineer-in-charge

2

-

-

... More
1. Load / Speed:20 Persons (1360Kgs.) / minimum 1.00 Mtr. Per Second. 2. Total Travel distance: (4.5+5.5+4.5+4.5) 19metre . 3.Machine Room:-YES. 4.Floor Display Char: LGF,GF,1ST,2ND & 3RD 5.Number of Landing Entrances: Five 6.Size of Lift Well: 2550X 2450 (MM Wide X MM Depth)

-

-

-

... More
VAV-11-GF-A 3815 1145

1

-

-

... More
Laying of one number additional PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade of following sizedirect in ground in the same trench in one tier horizontalformation including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
75 mm width x 25 mm depth x 1.6 mm thickness

1000

-

-

... More
UMDB-TF UPS MAIN DISTRIBUTION BOARD) ( THIRD FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 1 as per direction of Engineer-in-charge

2

-

-

... More
Including CI heavy duty manhole cover with frame of 560 mm internal dia for valve chamber. Total weight of the cover and frame to be not less thann 208 Kg(weight of cover 108 kg and weight on the frame than 58 Kg as per standard design.

74

-

-

... More
Providing and fixing 600mm long puddle flanges fabricated out of GI pipe heavy duty welded to 6mm thick M.S. plates along with flanges of suitable size hot dip galvanized properly fixed in walls and top slabs of underground and overhead tanks all complete as per direction of Engineer-in-charge :.

-

-

-

... More
6 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(vi) 0-16 A Ammeter with Ammeter selector switch & 16/5 C.T.s - 13 Sets

-

-

-

... More
1 no. 20A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Outgoing

-

-

-

... More
Supplying, Installation, Testing & Commissioning of Pre-fabricated sandwiched Aluminium bus duct suitable for 415 Volt 50Hz 3 phase 4 wire AC supply system of aluminium bus bars complete with bends, expansion joints, fire barriers, copper flexible end connections at both ends including Adaptor Box at Transformer end and DG Bellow at DG End. Earthing with 2 runs of copper earth as per IEC 60439 including necessary supports etc. as per specifications attached as required as per directed by Engineeer in Charge. Note : The bus trunking shall be measured along the length of enclosure. The copper/aluminium strips which will go inside L.T. panels & end termination boxes of transformers shall not be taken into measurement of bus trunking quantity).

-

-

-

... More
2 Set ON / OFF / TRIP indicating lights with SP MCB’s.

-

-

-

... More
Annunciator 12 Channel for DG faults - 24V DC - 3 No.

-

-

-

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.

-

-

-

... More
Supplying and fixing following rating four pole 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
• Portable water quality test kit - 1 Set

-

-

-

... More
3 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
3 Sets of 4000/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter

-

-

-

... More
Flexible Cover 40mm width

2240

-

-

... More
2 No. 150 mm dia dial type pressure gauges.

-

-

-

... More
PUMP PANEL - 1 (AT SERVICE BUILDING) as per directed by Engineeer in Charge.

2

-

-

... More
Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work.

1068

-

-

... More
(ii) Storage capacity of 25 Litres with vacume release valve and Model No. CDR 25V/H or approved equivalent make / model.

21

-

-

... More
7 no. 20A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Incoming

-

-

-

... More
Providing & Fixing Glass for Door Area of Structural Glazing system & shutter of Aluminium Internal Door 10mm thick Clear toughened of Saint Gobain or Equivalent etc. complete as per direction of Engineer in Charge. (Fixing charges included in the Basic item & this item is not applicable for Partition wall)

885

-

-

... More
Supply, Installation, Testing, & Commisioning of 2 Zone Fire Detection Panel with 1 Zone Gas Release Module with Battery back up. as per direction of Engineer in Charge.

48

-

-

... More
Supply, Installation, Testing & Commissioning of of 4:1 Switcher It should Allows up to four HDMI A/V sources to be connected to one HDMI display. It should Quick and easy switching between HDMI sources via front panel pushbuttons, RS-232 or IR Remote control. It should support long distance transmission up to 15 m (24 AWG). It should have Supports 340MHz bandwidth for ultrahigh 4kx2k video. It should support HDMI (3D, 4KX2K,Deep color) and should be HDCP 2.2 compatible. it should have Auto switching modes for auto port selection. it should support Max. Data Rate 9 Gbps (3 Gbps Per Lane). it should have LED indication of video source devices. it should support Max. Pixel Clock 300 MHz. It should support Dolby True HD and DTS HD Master audio. It should have Built-in bi-directional RS-232 serial port for high-end system control. it Supports IR extension using a IR extension cable. It should Instant switching between HDMI input sources. "it Supports resolutions of up to Up to 4096 x 2160 / 3840 x 2160 @ 60Hz (4:2:0); 4096 x 2160 / 3840 x 2160 @ 30Hz (4:4:4)." It should support Operating Temperature 0-50°C. Storage Temperature -20 - 60°C. Humidity 0 - 80% RH, Non-Condensing. It should support I/P rating 100-240 VAC; 50-60 Hz; 1.0A. Consumption 120 VAC, 36.6W; 230 VAC, 37.5W as per directed by Engineer in Charge.

1

-

-

... More
Supplying and fixing of 50 MM thick, glasswool / mineral wool insulation ( density not less than 120 Kg/m3 ) over the exhaust pipes of following diameter including cladding with aluminium sheet of 24 SWG or 0.6 mm and covering from outside complete, as required as per directed by Engineeer in Charge.

-

-

-

... More
(x) HRU-2F-02- 2300 CMH Ceiling Suspended

1

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as required.(but without charcoal or coke and salt )

24

-

-

... More
200 amps 25KA SC for 1 sec

64

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
(iii) HRU-GF-03- 1700 CMH Ceiling Suspended

1

-

-

... More
(b) ON / OFF / TRIP Indicating Lights with control fuses – 1 Set

-

-

-

... More
Particle board in partition Wall:- Design, Supply , Fabricate & Fixing 8 mm thick double skin multipurpose cement bonded wood particle board manufactured as per IS: 14276 with suitable cement bonded board screws. of approved make over existing frame(Paid in Separate Item) at Dry Partition wall / Partition Wall for rigidly fixed on any side (eachside measure separately) complete in all respect as per Design and as per direction of Engineer in Charge. Location as per drawing.(SHOP DRAWING TO BE PROVIDED & DULY APPROVED BEFORE EXECUTION OF THE WORK).

846

-

-

... More
LIFT NO.1,2,3 & 4/9,10,11 & 12/ 13,14,15 & 16/21,22,23 & 24 Group of 4 Nos. Car as per directed by Engineeer in Charge.

-

-

-

... More
Earthing with copper earth plate 600mm x 600mm x 3 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.

50

-

-

... More
(v) 10 A TP MPCB - 10 No.

-

-

-

... More
(i) 16 A TP MCCB - 13 No.

-

-

-

... More
Switch Socket - 5A/15A,3 Pin - 1 No.

-

-

-

... More
100 A, 25kA, FP MCCB

24

-

-

... More
STREET LIGHT FITTING : 60W(±10%) LED Streetlight with epoxy powder coated pressure die cast aluminium housing, electrochemically brightened anodised aluminium reflector, IP 66 protection, non -yellowing polycarbonate secondary lens optrics, 5KV built in surge protection and 10 KV external surge protection and with Luminous Efficacy =100 lm/watt, CRI70, Color Temp. =5700, Power Factor0.95 Luminaire performance: IS10322(Part5/Sec 3) & IEC 60598-1, IEC 60529 & complies IEC 62384, Certification: LM 79 & LM 80 Certificates, Min Delivered Lumens: 6000 lumen, Standard Deviation Colour Matching (SDCM) 4, an operating Voltage Range of 180 - 240 V, similar to Bajaj Cat. No. BRLEP 60W LED or equiv. Sample luminaire shall be got approved by Engineer-in-charge / consultant.

234

-

-

... More
Supply and fixing of acoustic treatment in AHU rooms and other areas as shown on drawings with 50mm thick resin bonded mineral wool of density 64 kg./m³ duly covered with perforated aluminium sheet complete as required and as per specifications. As Direction of E/C

10963

-

-

... More
FHC DOOR:- RED COLOUR PAINTED 35mm thick Metal Door SIZE 1500MM(W)X1200MM(H) Double Shutter Including Hardware(6nos. 100mmx75mmx3mm MS Butt Hinge, 4nos.300mm Long D-Type MS Handle Fabricated MS 20mm dia ROD, 1 no.250mm Aldrop) complete in all respect.

41

-

-

... More
LMDB-LGF (LIGHTING MAIN DISTRIBUTION BOARD) ( LOWER GROUND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 1 as per direction of Engineer-in-charge.

2

-

-

... More
(ii) 31.75 mm

130

-

-

... More
All ACB'S shall have spare wired contacts for ON,OFF,Trip,rackin,rackout spring charge status for SCADA / BMS communication along with LCD display.

-

-

-

... More
Concealed Type Unit

-

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
4 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
PUMP PANEL - 3 (AT MAIN BUILDING) as per directed by Engineeer in Charge.

2

-

-

... More
* - AHUs are with Electronic Clean air Filter

-

-

-

... More
3 no. 20A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
(iii) R,Y,B indication LED light with 2A MCB - 1 Set

-

-

-

... More
Communication cable: LSZH Communication Cable Cat 6E as per IEEE Standards complete with MS conduits

10000

-

-

... More
Under Voltage & Over Voltage protection with protection release.

-

-

-

... More
(iv) 3680 15

1

-

-

... More
630 amps 50KA SC for 1 sec

8

-

-

... More
200mm diameter UPVC. pipe

988

-

-

... More
3 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
a) 11 KW - 03 No.

-

-

-

... More
Circuit / Submain wiring in PVC conduit:- Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.2x2.5 sq. mm + 1x2.5 sq. mm earth wire(For circuit from LDB to SB)

500

-

-

... More
Supply, Installation, Testing and Commissioning of integral driver LED Steplight with a system lumen output of 40 lumens and a minimum system efficacy of 10lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI 75. The luminaire shall meet IP66 rating with THD 20% and PF 0.9. The luminaire shall have polycarbonate diffuser. The total Power Consumption should be within 4W to 8W (including driver). BIS certification to be provided seperately for luminaire and Driver. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.Similar to Philips Make LED STEPLIGHT "BWG150 LED4000/NW PSU 220-240V" or eqiv. Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

404

-

-

... More
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar,bent to shape with hooked ends in R.C.C. slabs or beams during laying,including painting the exposed portion of loop, all as per standard design complete.

3020

-

-

... More
Size-300mmx600mm

5762

-

-

... More
(i) 150 mm nominal bore.

2

-

-

... More
VAV-07-1F-F 6280 1884

1

-

-

... More
VAV-02-GF-D 3050 915

1

-

-

... More
Incoming

-

-

-

... More
VAV-01-3F-H 1850 555

1

-

-

... More
2x37 kVAr LT power capacitor banks with 2 No. 30 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
Oil separator suitable for the refrigerant piping.

-

-

-

... More
Supply, installation, testing, balancing and commissioning of linear powder coated extruded aluminium Return air grilles of various sizes and complete as per specifications.

246

-

-

... More
VAV-07-GF-E 4455 1337

1

-

-

... More
The chiller should be suitable for operating at low saturation pressure differential when the ambient wet bulb temperature falls to as low as 14 deg C during Winter particularly during night time.

-

-

-

... More
(vi) 6 A TP MPCB - 04 No.

-

-

-

... More
Providing and fixing 450mm long braded hose with two 15 mm nuts & rubber washers without nipple Jaquar Cat No. 805B, complete with C.P. brass flange including cutting and making good the walls wherever required as per direction of Engineer in Charge.

1539

-

-

... More
40mm nominal bore

2

-

-

... More
Supply, Installation, testing and commissioning of electrical driven rotary gear-pumps suitable for pumping of bulk storage from over flow tank to BOT as per directed by Engineeer in Charge.

4

-

-

... More
1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
Providing and fixing of Insulating Elastomeric (a genric term that includes rubbers, latex and elastomeric compunds that may be natural or synthetic or a mixture or a combination of both) mat with ISI mark of 1 mtr wide and 2.5mm thick to withstand 12 KV dielectric strength as per IS 15652-2006. as per directed by Engineeer in Charge.

12

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

936

-

-

... More
65 mm dia

16

-

-

... More
250,36kA, FP MCCB

8

-

-

... More
VAV-03-3F-C 1620 486

1

-

-

... More
d) 150 mm dia - MS `C' Heavy class pipe. (Welded/Flanged Joints)

3040.6

-

-

... More
(xxi) AH-1F-05 20 18500 4

1

-

-

... More
VAV-02-2F-D 2705 812

1

-

-

... More
Supply, Installation, Testing and Commissioning of integral driver LED Uplite with a system lumen output of 790 lumens and a minimum system efficacy of 50 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI 75. The luminaire shall meet IP67 rating and IK10 with THD 20% and PF 0.9. The luminaire shall have foggy glass closed diffuser. The total Power Consumption should be within 12W to 20W (including driver). Similar to Philips Make LED Uplite "BBP 330 9xLED HP/NW 220-240V 601N" or equiv. Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

40

-

-

... More
Movable Partition:- Providing & fixing Movable partition wall manual operated Variflex S 100 U of DORMA or EQUIVALENT for Conference Hall Wall Length upto 15m. Height upto 4.5m. Surface MDF Finish, parking as per drawing with track system & accessories complete in all respect and as per direction of Engineer in Charge .

2

-

-

... More
Lot, RCC foundation for the pump.

-

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

2734

-

-

... More
VAV-06-3F-F 3490 1047

1

-

-

... More
VAV-09-GF-A 3760 1128

1

-

-

... More
Providing & fixing Surface door closer, silver finish -

40

-

-

... More
Lubrication oil temperature indication

-

-

-

... More
(vi) 2000 550 900

1

-

-

... More
Supplying, installation, testing & commissioning of 6 inches dia, 2 watts, 70/100 volts ceiling speaker complete as required.

2508

-

-

... More
(d) R, Y, B phase indicating LED light with 2A MCB - 1 set

-

-

-

... More
80 mm dia

10

-

-

... More
GENERAL NOTES : 1. All items of work under this Contract shall be executed strictly to fulfill the requirements laid down under “Basis of Design” in the specifications. Type of equipment, material specification, methods of installation and testing and type of control shall be in accordance with the specifications, approved shop drawings and the relevant Indian Standards, however capacity of each component and their quantities shall be such as to fulfill the above mentioned requirement.

-

-

-

... More
Floor Finish:- With High quality Marble in Pattern (Paid in separate item)

-

-

-

... More
(i) 0-1000 Ammeter with Ammeter selector switch and 1000/5 C.T.s -1 Set

-

-

-

... More
(c) 25 mm nominal bore.

248

-

-

... More
For Metal Door :- Providing , testing & retain 65 mm dia PAD LOCK Brass Body,7 Brass Levers, 2 Brass Keys with master key arrangement floor wise & corrosion free Hardened Shackle.

772

-

-

... More
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, Second class teak wood.Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured).

156

-

-

... More
PMDB-FF (POWER MAIN DISTRIBUTION BOARD) ( FIRST FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 1 as per direction of Engineer-in-charge

2

-

-

... More
100 mm width x 40 mm depth x 1.6 mm thickness

3000

-

-

... More
Note: All metering current transformers shall be Class 0.5, 05 VA, cast resin type.

-

-

-

... More
Providing & fixing Fire rated Panic Bar (For Fire Metal Door)

428

-

-

... More
Supply, Installation of Cylinder Bracket for 40 ltr

2

-

-

... More
(iv) 300 mm width X 50 mm depth X 1.6 mm thickness

200

-

-

... More
2 Sets of 1000 A 4P ACB 50 KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings

-

-

-

... More
AHU Tag. Cooling Load (TR) Air Qty. (CMH) Cooling Coil (Row)

-

-

-

... More
1. Load / Speed:20 Persons (1360Kgs.) / minimum 1.00 Mtr. Per Second. 2. Total Travel distance: (4.5+4.5+4.5+4.5) 18metre . 3.Machine Room:-YES. 4.Floor Display Char: LGF,GF,1ST,2ND & 3RD 5.Number of Landing Entrances: Five 6.Size of Lift Well: 2550X 2450 (MM Wide X MM Depth)

12

-

-

... More
Under frequency / Over frequency relay

-

-

-

... More
VAV-01-3F-A 3740 1122

1

-

-

... More
(g) 80 mm nominal bore.

45.12

-

-

... More
The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.66 mm overall thickness partition using 8 mm thick double skin multipurpose cement bonded wood particle board manufactured as per IS: 14276 with suitable cement bonded board screws.

1100

-

-

... More
7 no. 20A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
630A, 11 kV, 3-Phase, 25 KA for 3 sec., 50 Hz 3 strip Copper Bus bar

-

-

-

... More
Providing & fixing Multi Bolt Mortise Lock Body Left & Right operation suitable for Wooden Flush door including cylinder, Locking hole cover for one side, inside locking knob with Floor wise Master key arrangement complete in all respect as per direction of Engineer in Charge. Material SS304 & SS finish.

1283

-

-

... More
150 mm width x 50 mm depth x 1.6 mm thickness

20

-

-

... More
(ii) 150 4P MCCB - 02 No.

-

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
P/L NP2 class R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of (1:2):100 mm dia. R.C.C. Pipe

200

-

-

... More
2 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
(i) 230 mm dia ≤ 1400 RPM

10

-

-

... More
Call Billing Software as per directed by Engineer in Charge

2

-

-

... More
(ix) 28900

1

-

-

... More
Dia 250mm - 9 No.

-

-

-

... More
3.5 C x 150 sq mm A2XFY cable

1502.76

-

-

... More
VAV-07-GF-A 4051 1215

1

-

-

... More
Supply, laying testing and commissioning of Oil piping with class C MS pipes laid in existing masonry trenches/hume pipes including the cost of bends, supports, clamps etc. and including the cost of surface preparation of pipes, application of primer paint coat and including the cost of hydro testing complete as required as per directed by Engineeer in Charge.

-

-

-

... More
3200 A, 415V, 3 strip, 50 KA, 50 Hz Aluminium Bus bar

-

-

-

... More
DDC- 18

2

-

-

... More
Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

556

-

-

... More
(xiv) 0-10 A Ammeter with ammeter selector switch & 10/5 CT's - 10 Sets.

-

-

-

... More
Supplying, installation, testing & commissioning of Outdoor type Control Panel

8

-

-

... More
VAV-07-GF-A/VAV-04-1F-H 2700 810

2

-

-

... More
6 no. 20A DP MCCB

-

-

-

... More
(g) 80 mm nominal bore.

2

-

-

... More
2 Sets of 4000 amps 4 pole 65KA electrically operated Electrically draw out type air circuit breaker.

-

-

-

... More
a) 65 mm dia - MS `C' Heavy class pipe. (Welded/Flanged Joints)

1749.711

-

-

... More
(a) 150 A 4P MCCB – 1 No.

-

-

-

... More
(d) 40 mm nominal bore.

2

-

-

... More
Supplying, installation, testing & commissioning of 54 watt RGB wallwasher Light, Protection : IP65 Class 1, Input Voltage : 220V AC, Operating Voltage : 24V DC, Power Consumption : 54 watt, Beam Angle : 8 deg, Control Mode : DMX, Housing : Aluminium Alloy, Operating Temp : -20 to 50 deg, 3 pin XLR input/output,

116

-

-

... More
DDC- 8

2

-

-

... More
Outgoing

-

-

-

... More
1600 A, 415V, 4 strip, 35 KA, 50 Hz Aluminium Bus bar

-

-

-

... More
(i) 150 mm nominal bore.

4

-

-

... More
SITC of Clamp for connecting air terminal rod to 8mm Conductor,confirming to EN 62561 and according to IS/IEC 62305 as per direction of Engineer-in-charge

156

-

-

... More
(xxviii) AH-2F-04 17 15100 4

1

-

-

... More
VAV-02-2F-B 3085 926

1

-

-

... More
(a) 15 mm nominal bore.

1585

-

-

... More
Electronic Level switch High & Low for Over flow Tank & Buffer tank

4

-

-

... More
1 Set of 1600/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.)

-

-

-

... More
Waterproofing of Wet Floor areas: Providing and laying water proofing treatment on Toilet, Pantry & Balconies floor slab consisting of following :-( Rate is inclusive all items except mentioned. Floor to be Prepared as required Level providing 1:5:10 Conc. Paid in separate item) 1.Surface Preparation: All surfaces to receive the waterproofing to be mechanically cleaned properly so that there will be no dust, laitance, oil, grease etc. (To check a pond test to find out sign of seepage from soffit. On identification of week concrete, seepage through joints and honeycomb necessary grouting to be done with suitable material of approved manufacturer with their direction with contractor's own cost) 2.Coving:Coving to be done at all junctions by cutting V grooves of 20 mmX 20 mm at Junction and filling with cement-sand (1:4) mortar admixed with (Sika Top 77 /Nitobond SBR Latex of FOSROC/ BASF Master Emaco SBR 2) of approved manufacturer with their direction. 3.Bore Packing: Bore packing to be done at all pipe entries with suitable material (Sikaflex 11 FC/Fosroc Nitobond SBR Latex/ BASF Master Emaco S 340) of approved manufacturer with their direction. 4.Water proofing product:-Supply and apply water proofing coating of minimum thickness 2mm (Topseal 107/Brushbond RFX/Dr.Fixit Pidifin 2K/Master Seal 550) on floor, polymer modified product as per approved manufacturer with their direction. 5.Covering with Screed plastering:-After curing Providing only integral waterproofing admixture (Sika Plastocrete Plus/Fosroc Brushbond RFX/BASF Master PEL 777) of approved manufacturer & direction for portion. ( Note:-1. Using this admixture mixing with mortar for backing mortar using for Floor finish item under supervision of waterproofing agency for no damage of treated area. 2. Floor finishing will be done over sand cement mortar will be paid in separate item). As per direction of Engineer in Charge

4824

-

-

... More
Extra for arches, domes, vaults exceeding 6 m span

5830

-

-

... More
Labour charges for laying of temporary floor protector including Cost and conveyance of tape, cutting and placing to the required size etc. at all levels complete as per direction and satisfaction of Engineer-in-charge. All butt joints should be taped off with good quality 60mm wide BOPP tape.

151205

-

-

2

-

-

... More
(iii) 1950 500 900

1

-

-

... More
Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplaster concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. )

87132

-

-

... More
j). Modem for Remote Maintenance,

-

-

-

... More
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required.

136

-

-

... More
Providing , lowering & laying in trenches, aligning & jointing of PVC-U pipes for drainage of SDR 34/Ring stiffness SN 8 KN per Sqm as per IS: 15328 and as per specification with rubber ring with socket and spigot joint, (EPDM/SBR) for all depths including well graded granular bedding (Type-E) for pipe length as per drawing and specification including hydraulic field testing and commissioning etc complete as directed by Engineer. Note : Earth work will be measured and paid separately.

-

-

-

... More
VAV-03-GF-E 3432 1030

1

-

-

... More
Travel : 4.5 METER for Each Floor except otherwise mentioned.

-

-

-

... More
40 MMX 40MM

1000

-

-

... More
(vi) TFA-LGF-01 15 4850 8

1

-

-

... More
Supply, Installation, testing and commissioning of 990 litres capacity buffer oil storage tank fabricated from 2 mm thick MS plates. Tank shall include 450 mm ID manhole cover, level indicator and flanged connection for inlet, outlet, overflow drain and probe provision for level controller. Tank shall be mounted on 2 m high structure support with access ladder (painted with 2 coats of red oxide primer) as per directed by Engineeer in Charge..

2

-

-

... More
Supply, Installation, Testing & Commissioning of Microprocessor based networkable analogue expandable type addressable type sub fire alarm panel with suitable loop card and amplifier wattage . Each loop card and amplifer should have 20% spare capacity for future provision. Panel should have min. 640 character LCD display. The panel shall have access levels, capable of record upto 1000 event log history, sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump. Panel should operate with 240 volts AC power supply, automatic battery charger of suitable capacity , 24volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 min during an emergency conditions as required. The panel should have port to connect online printer.System is capabale of generate alarm condition if central processing unit fails. The network shall support min 64 panels / nodes per network.(UL 9th or latest Edition Approved and FM approved). Mounting accessories of main fire panel, electrical connectivity from nearest DB and civil works shall be in the scope of bidder.(SUB FIRE ALARM PANEL IN EACH FLOOR) as per directed by Engineer in Charge.

10

-

-

... More
Providing and laying of Filter media with granular materials / stone crushed aggregates / brick aggregates / river bed materials satisfying the requirements laid down in clause 2504.2.2 of MoRT&H Specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification.

274

-

-

... More
Bus Bar

-

-

-

... More
VAV-05-GF-A 3000 900

1

-

-

... More
1 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
2 Set of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
5. In the event of an error occurring in the amount of the Schedule, as a result of wrong extension of the unit rate and quantity, the unit rate quoted by the tenderer shall be regarded as firm and the extensions shall be amended on the basis of rates.

-

-

-

... More
VAV-04-2F-H 1575 473

1

-

-

... More
(ii) 16 A TP MPCB - 09 No.

-

-

-

... More
35mm thick Metal Door SIZE 1200MM(W)X2100MM(H) Double Shutter Including Hardware (6nos. 100mmx75mmx3mm MS Butt Hinge, 2nos.300mm Long D-Type MS Handle Fabricated MS 20mm dia ROD, 2 nos.250mm Aldrop and 1 no. vision panel 3mm float glass Width300mmxHeight500mm) complete in all respect.

18

-

-

... More
PMDB-LGF (POWER MAIN DISTRIBUTION BOARD) ( LOWER GROUND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 1 as per direction of Engineer-in-charge

2

-

-

... More
1 Set of 320/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Door Shutter Framework for Fire rated Glazed Door :-Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc. all complete as per direction of Engineer-in-charge ( Glaze paneling to be paid for separately).

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
VAV-01-2F-G 3595 1079

1

-

-

... More
Fouling Factor of Condenser & Cooler : As per data sheet

-

-

-

... More
By pass line nominal size : 200 mm

-

-

-

... More
40mm dia

1990

-

-

... More
d) 3.7 KW - 01 No.

-

-

-

... More
Supplying, installing, testing and commissioning of Video wall retractable bracket (Make-Standard) as per directed by Engineer in Charge.

4

-

-

... More
(viii) Dia 50mm

586

-

-

... More
VAV-01-2F-B 965 290

1

-

-

... More
(iii) R,Y,B indication LED light with 2A MCB - 1 Set

-

-

-

... More
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments,pillars, posts, struts, buttresses, string or lacing courses, parapets, coping,bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

60

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

100

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
SECONDARY CHILLED WATER VARIABLE SPEED PUMPING SYSTEM 2W+1SB Supply, installation, testing and commissioning of secondary chilled water variable speed pumping system comprising the following and complete as per specifications As Direction of E/C

3

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete all complete as per direction of Engineer-in-charge :

-

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler.

-

-

-

... More
a) 11 KW - 03 No.

-

-

-

... More
32mm dia

12000

-

-

... More
Designer Jali work on 8mm thick MDF Board with polish finish.

126

-

-

... More
c) 18.5 KW - 6 No.

-

-

-

... More
Providing & fixing flush manual Door sliding system with necessary track of Aluminium section, Lock with knob inside & Door Handle for both side of approved Make complete in all respect as per direction of Engineer in Charge.

43

-

-

... More
2 X 10 sq. mm + 1 X 6 sq. mm earth wire

11208

-

-

... More
80mm dia

1000

-

-

... More
2 NO type - 2 SPD with in built fuse.

-

-

-

... More
VAV-02-2F-A 2290 687

1

-

-

... More
Outgoing

-

-

-

... More
Bus Bar

-

-

-

... More
Incomer

2

-

-

... More
Note: All metering current transformers shall be Class 0.5, 05 VA, cast resin type.

-

-

-

... More
(b) 4.5 kg CO2 High Pressure Portable Fire Extinguisher, filled with Co2 Gas as per IS 15222, Gross Weight 16.4, empty weight 11.9 Kg, Control discharge mechanism fitted with 1 Meter Wire Braided Hose & Flat Horn with Diffuser Nozzle for dispersed discharge of CO2, Discharge Time 12 Sec, Average Discharge is 95%, Applicable on Class B, C and electrically started Fire, Fire Rating 21B, Internal coating is not applicable & External coating is of enamel spray painting, Powder Coated Handle, Valve Confirm to IS 3224 ISI Marked, CO2 Cylinder construction: hot spinning by seamless pipes & bearing ISI mark, Body confirms to IS 7285 and PESO APPROVED, Extinguishers confirmed to IS 15683:2006 and ISI marked.

884.2

-

-

... More
VAV-02-LGF-G 3230 969

1

-

-

... More
(b) ON / OFF / TRIP Indicating Lights with control fuses – 1 Set

-

-

-

... More
DDC- 36

2

-

-

... More
Supply, Installation, Testing & Commissioning of Audio De Embedder Should repeat HDMI input signal up to 15 meters • Should extract HDMI audio signal and outputs as additional audio source Should support optical / coaxial digital audio and analog stereo audio • Should be HDCP 1.1 compatible • Should support Superior Video Quality – up to 1920x1080 (1080p) • Firmware should be upgradable • Should have CH2/CH5.1/Auto mode audio channel selection • Should support Dolby True HD and DTS HD Master Audio • Should support Audio on/off switch for HDMI output • Should be expandable to three levels – provides three levels of audio output for one HDMI at distance up to 45 m • Should integrate with Apple or equiv. TV for the perfect home entertainment system as per directed by Engineer in Charge

1

-

-

... More
3.5 C x300 sq mm A2XFY cable

33363.22

-

-

... More
Condenser Water Flow- 3420 LPM

-

-

-

... More
LMDB-LGF (LIGHTING MAIN DISTRIBUTION BOARD) ( LOWER GROUND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 2 as per direction of Engineer-in-charge.

2

-

-

... More
(f) 50 mm nominal bore.

1864

-

-

... More
4 Strip aluminium bus bar of 500 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
Pump Minimum efficiency shall be 75%.

-

-

-

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, design of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete as specified and as directed by Engineer-in-charge.

-

-

-

... More
Supply,installation,testing and commissioning of Dual plate Non return valve of cast iron 210 Gr., ASTM A-217 Gr. Plates - SS410, Hinge/ Stop Pin SS- 316 with EPDM seal, PN 16 rating complete with insulation & all other parameters as per the technical specifications given in the tender. As Direction of E/C (i) 200 mm dia

12

-

-

... More
Supply, installation, testing and commissioning of following types of Extinguishers with provision of wall bracket (fixed with anchor fastner)..as per direction of Engineer in Charge.

-

-

-

... More
Outgoing

-

-

-

... More
2 Sets of 400/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Providing P.C.C M-150 with nominal mix of (1:2:4) in foundation with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of P.M. 2.5 to 3 including screening, shuttering mixing cement concrete in mixer and placing in position,vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of Engineer-in-charge

3190

-

-

... More
Flow - 3690 LPM

-

-

-

... More
Size-600mmx600mm

338

-

-

... More
(vii) R,Y,B indication LED light with 2A MCB - 1 Set

-

-

-

... More
600 mm width x 50 mm depth x 2.0 mm thickness

8

-

-

... More
Supplying, installation, testing & commissioning of CAT6A Patch Cord (User End) as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

7380

-

-

... More
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :

-

-

-

... More
Supplying and installing at approved location approved make pair of 4 nos.fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of supporting stand, hanging bars & hooks etc comply and painting providing MS stand duly painted over a coat of primer. (Distinctly identified as "WATER & SAND").

20

-

-

... More
Single headed Gunmetal

270

-

-

... More
3.5 C x 150 sq mm A2XFY cable

36

-

-

... More
(iii) 200 mm width X 50 mm depth X 1.6 mm thickness

300

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
1 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Selected cooling tower shall be certified for test procedure as per CTI ATC–105 and CTI STD–201

-

-

-

... More
Providing two coats of synthetic enamel paint over a coat of primer of approved shade and make over new wooden surface after cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffolding and taxes all complete as per building specfication and direction of E/l.

2321

-

-

... More
Providing and fixing to existing door frames 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge.(BUTT HINGE INCLUDED IN THIS ITEM)

926

-

-

... More
(xii) 3.0c x 4 sqmm

120

-

-

... More
Supplying, fitting and fixing Starwhite glazed vitreous Division plates for urinals (Hindware Cat no. 61001 or approved equivalent) of size 68 x 30 Cms as per direction of Engineer In Change.

223

-

-

... More
1 No. dedicated microprocessor based pump logic controller with parallel pumping software duly down loaded and capable of controlling upto 3 pumps in parallel / accepting 2 analog input from sensor / sensor less logic and should be capable of communicating with Building Management System by both hardware and software integration.

-

-

-

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).

309688

-

-

... More
300 mm width x 50 mm depth x 1.6 mm thickness

12

-

-

... More
63mm OD Class 6(PN)

160

-

-

... More
Providing & fixing 150 mm dial type Pressure gauge of (0-16kg/cm2) range with gun metal shut off cock etc. duly calibrated before installation in MKS and FPS units and fixing the same where required as directed including all fittings, short piece, nipples, elbows testing the joints etc.all complete. (Quantity of this item will be payable only where it has not been included in the relevant composite items). as per direction of Engineer in Charge.

80

-

-

... More
2 Sets of 2500 A 4P ACBs 50 KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings with ATS arrangement.

-

-

-

... More
4 Sets of 4000/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Chilled Water flow: 2958 LPM

-

-

-

... More
VAV-04-GF-E 2710 813

1

-

-

... More
VAV-06-1F-B 4180 1254

1

-

-

... More
(iii) R,Y,B indication LED light with 2A MCB - 1 Set

-

-

-

... More
( c) ABC Type Fire Extinguisher Cap. 4 kg Filled with Mono Ammonium Phosphate Powder 90% confirms to IS 14609, Stored Pressure Type, UGTS Pressure Gauge, Gross Weight 8.9 Kg, Empty Weight 2.9 Kg, Can Height 530 mm, Diameter 150 ± 10mm, Discharge Time 24 Sec, Controllable discharge mechanism, Jet Range 5 Meters, Average Discharge is 90%, applicable on Class A,B & C and electrically started Fire, A Rating- 3A, B Rating 21B, Can Construction : Deep drawn & CO2 Mig welded, EPDM Rubber Hose with both end Aluminum clamped, Internal Coating - Epoxy Powder coating, External Coating - Pure Polyester Powder coating (UV Resistant), Brass forged valves with safety Pin is of SS material, Sheet metal thickness : 1.8 mm, ISI Approved IS 15683:2006.

884.2

-

-

... More
1 Set of 32/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
(xv) 0-6 A Ammeter with ammeter selector switch & 6/5 CT's - 04 Sets.

-

-

-

... More
200mm diameter

5

-

-

... More
(vi) Dia 80mm

812

-

-

... More
Supply, Installation, Testing and Commissioning of LED Recessed Downlighter with pressure die cast housing. Nominal system lumen output of 1500 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a CCT 5700k or 6500k, CRI 80, PF 0.95, an operating Voltage Range of 220V- 240V, Standard Deviation Colour Matching (SDCM) =3 to =5. The luminaire shall meet IP20 rating with THD10% and PF 0.9. The luminaire housing should made of pressure die cast aluminium .The total Power Consumption should be within 12W to 16W (including DALI driver).Similar to Philips Make GREENPERFORM SLEEK "DN 296 LED15S-6500 PSD WH" or eqiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification Required: LM 79 & LM 80 . Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

3187

-

-

... More
Supply, Installation, Testing, & Commisioning of Smoke Detector

462

-

-

... More
VAV-07-GF-D 3264 979

1

-

-

... More
DIGITAL AUDIO -VIDEO and CONFERENCE SYSTEM : Note: 1. All special fixtures, equipments, accessories, control devices, attachment etc. not specifically mentioned but are required for proper functioning and efficiency of system shall be included in the offer. 2. Power Supply (if any) - A source of electrical operating power (UPS, including the circuits and terminals connecting it to the dependent system components are in the scope of bidder. 3. The bidders shall include the cost of system integration, software programming, system testing, commissioning, training to departmental engineers, hands-on demonstrations of the operation of all system components and the entire system, documentation (the systems manufacturer's representatives shall provide a typewritten "sequence of operation" to the owner) etc. oem as per technicial specifications shall be included in the offer. The cost of system integration shall be included proportionally in the rates of items indicated in the bill of quantities. 4. OEM should have authorized service centre in India as per directed by Engineer in Charge.

-

-

-

... More
EPABX Software/ Management softw as per directed by Engineer in Charge are

-

-

-

... More
CAPACITY TAG TYPE

-

-

-

... More
7 no. 25A 4P MCCB

-

-

-

... More
Geophysical investigation of the aquifer by electro logging system with all tools and plants as necessary including supply of necessary report as per direction of Engineer-in-charge:.

2

-

-

... More
VAV-02-GF-A 2750 825

1

-

-

... More
25 mm nominal outer dia .Pipes.

2326

-

-

... More
80 mm dia

16

-

-

... More
2 way Electronic pressure independent Control Valve with an equal percentage flow characteristics with modulating actuators for cooling coils of Air handling units. Valve shall be Electronic Pressure Independent control Valve that measures flow using sensors with no moving parts. Valves shall be duly insulated with same material as on pipe, PN16 rated, along with electronic modulating thermostat with digital display in square size, with necesary wirings and transformer, complete in all respect, as required and as per specification.

-

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

16100

-

-

... More
(f) 65 mm nominal bore.

2

-

-

... More
4 no. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Wooden Slat:- Supply and Installation as per Drawing and design of false ceiling single or combination with other type false ceiling high density fiber board made out of pure pinewood particles , Fire Resistance - Pink in colour core with 5 test Fire Resistance BS 476 part 5 , BS 476 part 6 , BS 476 part 7 ISO 1182 ASTM E662 Smoke Density - Melamine laminated finish, perforated wooden grooved HDF slats L16-2 (2 mm grooves @ 8 mm centers),tongue-groove edge for a seamless look of lineal dimension size 128 mm x 2440 mm x 16 mm thick having density 700 Kg /m3, weight -9 Kgs/m2 with back fleeces from soundtex Germany nonwoven acoustic to be pasted on slats source is to be installed by using GI strut system. The technical parameters are as follows Core Variants - Fiberboard, Climate (OC RH) – 50, 70 Light reflectance – 75%,Green (RC %) – 25, Hygiene (VOHC, Clean room) – Low, Class 1,Strength, Load capacity (Kg) - Anti sag, Ball-Impact. The GI strut system includes GI cross channel ( CC 25 ) having thickness 0.45 mm, length 3600 mm, knurled web 40 mm, depth 25 mm and equal flanges 9.5 mm is fastened vertically at every 600 mm centers. Aluminum core cross channel (CC 18) having thickness 0.5 mm, length 2400 mm, web 15 mm & 27 mm, depth 18 mm and flanges of 7 mm with suitable edge & center brackets is then fixed perpendicular to the CC 25. Now the system is to be suspended on GI frames as per the specification for fixing concealed grid ceiling system. The concealed ceiling system shall include GI Wall channel(WC 27) having thickness 0.45 mm, length 3600 mm, unequal flanges of 15 & 20 mm and web of 27 mm should be fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every

-

-

-

... More
4 Core x 2.5 Sq.mm Cable

24

-

-

... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. Note for Interior Work:- A special agency of sufficient credential duly approved from the architect & the Engineer in Charge before execution the Interior Work.(Shop drawing should be approved by the Architect before execution of the work)

436909

-

-

... More
Supplying, installing, testing and commissioning of a digital desktop delegate microphone unit with a 15” or longer gooseneck microphone with a super-cardioid capsule, 3.5mm headphone output jack, RJ45 jacks and twin loudspeakers which will connect to the central control unit via network using industry standard Category 5 (24 AWG) cabling. Optional strain reliefs can be provided for fixed installations. The audio signal path shall include a digital signal processor limiter. Operating voltage shall be 35vDC to 52.8vDC. Maximum power consumption shall be 3.8W. Total harmonic distortion shall be a maximum of 0.03% at 50mW/16 Ohms as per directed by Engineer in Charge.

12

-

-

... More
Supply, Installation, Testing & Commissioning of Bulk cables and connectors with LAN I/O ports for VC and requisite UPS power point for rack as per directed by Engineer in Charge.

1

-

-

... More
5 no. 40A 4P MCCB,Thermomagnetic controlled.

-

-

-

... More
Chilled Water Outlet Temperature: 6.66 deg C

-

-

-

... More
300 mm dia NB pipe 4.85 mm thick plate

72

-

-

... More
920 KVAR (Seleected actual Rating may be 1149KVAR) LT Capacitor Panel-1

1

-

-

... More
Outgoing

-

-

-

... More
VAV-02-2F-H 3055 917

1

-

-

... More
Each capacitor bank must have 1 set of on/off indication LED type.

-

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: 50 mm dia. (Supplying, fitting and fixing G.I Column Pipe including flanges with Nuts, Bolts and Washers at both ends, threading where required, coupling, painting etc. all complete (Length of the pipe coupled with pump motor set to be approx. 600 mm, topmost pipe to be approx.1500 mm long and rest of the pipes to be approx. 3 meters long each)

480

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab upto 0.50 sqm

9791

-

-

... More
Voltage Raise Relay .

-

-

-

... More
2 no. 32A 4P MCCB, 25 KA Thermomagnetic controlled.

-

-

-

... More
(ii) 0-500 V Voltmeter with Voltmeter selector switch and control fuses - 1 Set

-

-

-

... More
(ix) 0-25 A Ammeter with ammeter selector switch & 25/5 CT's - 02 Sets.

-

-

-

... More
Size- 300mmx450mm

17051

-

-

... More
Auxiliary contacts required for necessary interlocking of breakers.

-

-

-

... More
For Matt Finish of Sizes 800mmX800mm .

72708

-

-

... More
Providing & fixing Fire rated concelled flush bolt SS finish 300mm long (For Fire Metal Door)

214

-

-

... More
2 Sets of 4000/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
VAV-04-GF-A 1910 573

1

-

-

... More
16 Sets ON / OFF / TRIP indicating lights with SP MCB’s.

-

-

-

... More
VAV-01-GF-E 1652 496

1

-

-

... More
(ix) 3.0c x 16 sqmm

64

-

-

... More
5 nos. 40A 4P MCCB Thermomagnetic controlled.

-

-

-

... More
2 Set of 4000 A 4P ACBs 50 KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings with ATS arrangement.

-

-

-

... More
1 Set of 630 A 4P MCCBs 35 KA miroroprocessor based controlled with overload, short circuit and earth fault protections.

-

-

-

... More
BACnet / MOBUS / Open protocol compatible communiction card for integeration with BMS

-

-

-

... More
Y Strainer 50mm dia

8

-

-

... More
(ix) AH-GF-01 32 29100 4

1

-

-

... More
3 no. 20A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign mater;al etc. and lining out complete. New work (Two or more coats)

2000

-

-

... More
BMS Server BMS Server shall comprise of the following minimum hardware: Intel i7 min 3.2 GHz processor, 12 GB of RAM or higher, 22” LED Color Display (1280 x 1024) , 12 function-126 key keyboards (English) Mouse pointing device; 1TB HDD for OS & BMS Software, and BMS Database. DVD Combo Drive, Graphics Card – NVS 630 or higher version,1024MB DDR3 or better; NIC (network interface card) for Ethernet Networking compatible with TCP/IP network protocols (UTP/Fiber); Complete with with Original AntiVirus, MS Windows Client Software and operating license as per directed by Engineer in Charge.

2

-

-

... More
MDF, IDF Junction Boxes as per directed by Engineer in Charge

2

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C (Primary Light Points )

16928

-

-

... More
Incoming

-

-

-

... More
Serrated with central bulb (225 mm wide, 8-11 mm thick)

6636

-

-

... More
(iv) Dia 125mm

90

-

-

... More
DDC- 5

2

-

-

... More
80 mm dia vent pipe

12

-

-

... More
(vii) R,Y,B indication LED light with 2A MCB - 1 Set

-

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Incoming

-

-

-

... More
Supply, installation, testing and commissioning of pressure independent AHRI certified variable air volume (VAV boxes) consisting of BACnet /MSTP commubicable DDC controller,damper actuator, low pressure velocity transducer and temperature sensor ( with digital room thermostat). integral sound attenuator made of 22 Gauge GI sheet, casing consisting of 25 mm thick 48kg/m³ density rock wool, volume control damper, caliberated diffrenetial pressure sensor at inlet complete with controller, control wiring etc. as required and as per specificaiton and drawings. VAV should be dynamically calibrated & tested in factory on live test bed as per designed CMH.

-

-

-

... More
STREET LIGHT POLE :- 7.0M height (above ground lev.) 3MM steel thick, hot dip galvanised (as per BS EN ISO 1461) and polyurethane paint (PU paint) round conical pole (Top dia - 75MM, bottom dia - 151mm) with 1.0M long decorative single arm bracket along with foundation bolts (4mm x 20mm x700mm), baseplate (250mm x 250mmm x 16mm) accordingly or to pole manufacture. Shaft shall be as per BS EN 10025. Poles shall be made in single section and shall be suitable for wind loadings as per IS 875 part 3 1987 or latest. The inbuilt terminal box shall be splash proof, vandal proof , suitable for mounting in given pole internally with clamping/fixing arrangement. The enclosure shall have recessed hinged door with neoprene gasket and locking arrangement. Each enclosure shall be adequately sized to house terminal blocks to loop in and out 2-3 Nos. 4C x 10mm2 cables, Neutral link and 2 Nos., 10A MCBs with base. All above components to be rigidly mounted on back plate. The box shall have earth terminal on inside and outside for connecting earth wire. For fixing earth wire one bolt shall be welded to the pole and provided with suitable nut washer and spring washer. GA drawings shall be in the scope of bidder and same shall be got approved by Engineer-in- charge / consultant.

234

-

-

... More
Note: All metering current transformers shall be Class 0.5, 05 VA, cast resin type.

-

-

-

... More
a. All materials, fixing materials, accessories, appliances tools, plants, equipment, transport, labour and incidentals required in preparation for and in the full and entire execution, testing, balancing, commissioning and completion of work called for in the item and as per Specifications and Drawings.

-

-

-

... More
Daily service fuel tank of 990 liters capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.

-

-

-

... More
(iii) 125mm dia

8

-

-

... More
2-way Modulating valve complete with actuator and capable of accepting 0-10V DC for 6.6 deg C Chilled Water System (Valves to be handed over to the Piping Contractor for installation). The sizes of the valves indicated below are tentative. The successful vendor shall select the valve required for the duty conditions and get the approval of the consultants before ordering the valves

-

-

-

... More
(i) 0-150 Ammeter with Ammeter selector switch and 150/5 C.T.s -1 Set

-

-

-

... More
(d) R, Y, B phase indicating LED light with 2A MCB - 1 set

-

-

-

... More
Design, supply fabricate and fixing factory made aluminium Louver Aluminum Extrusions, Powder coated finish complete in all respect as per instruction of Engineer in charge.

471

-

-

... More
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete

262

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. (a) Extra depth for 90 cm x 80 cm manhole beyond 0.45 m depth.

435

-

-

... More
Cranking Relay

-

-

-

... More
7 Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
(xii) 0-6 A Ammeter with ammeter selector switch & 6/5 CT's - 03 Sets.

-

-

-

... More
VAV-01-1F-D 3575 1073

1

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 pipes.mm gap for thermal expansion, (i) Single socketed Pipes.

-

-

-

... More
Providing wrapping and coating to outer-surface of underground G.I. / M.S. / D.I. pipeline as per I.S: 10221 with a layer of 4 mm thick wrapping and required coatings. (alternatively two layers of 2 mm thick wrappings with required coatings may be provided but without any extra cost) as per direction of Engineer in Charge..

-

-

-

... More
b) 100 mm dia M.S. 900 plain bend.

36

-

-

... More
Refrigeration Load : 300 TR (Actual) ( 2 W+1SB)

-

-

-

-

-

-

... More
3.5 C x 50 sq mm A2XFY cable

5536.09

-

-

... More
Extra for fixing the louvers/shutters complete with frame for a exhaust fan of all sizes.

72

-

-

... More
DDC- 39

2

-

-

... More
Bus Bar

-

-

-

... More
Sealed Maintenance Free Battery - 12V, 40AH - 2 No.

-

-

-

... More
(i) Nominal line size : 250 mm

6

-

-

... More
4 nos. 800A 4P EDO ACB

-

-

-

... More
Bus Bar

-

-

-

... More
VAV-06-3F-A 4390 1317

1

-

-

... More
(d) R, Y, B phase indicating LED light with 2A MCB - 1 set

-

-

-

... More
Providing and fixing preapproved Kota stone slabs 20 mm thick semi polished in risers of steps with single piece laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete with Single piece all lead & lift as specified and as directed by Engineer-in-charge.

578

-

-

... More
DDC- 14

2

-

-

... More
Operating and maintaining the plant round the clock for two years from the date of virtual completion as detailed in the condition of Contract and Technical Specification, i.e. after successful testing and commissioning and furnishing test reports on treated water from multigrade filter and softner from approved agency, imparting training to the owner's staff to run the plant and including cost of all spares, consumables including common salt, all chemicals, top-up of resin etc. and required man-power deployed round the clock during O&M period (Cost of Power & Water will be borne by the Owner) - 1 job as per direction of Engineer-in-charge:

48

-

-

... More
Supply, installation, testing, balancing and commissioning of square powder coated extruded aluminium Return Plaque air diffusers of various neck sizes complete as per specifications.

10

-

-

... More
f. In the event of conflict between Schedule of Quantities and other documents including the Specifications, the most stringent shall apply. The interpretation of the Engineer incharge shall be final and binding.

-

-

-

-

-

-

... More
NON FIRE RATED ACCESS CONTROLLED ALUMINIUM (Powder Coated Extruded section) FRAMED GLASS DOOR :-Supply , Installation & Commissioning of ACCESS CONTROLLED Aluminum extruded section duly powder coated Frame with 8mm thick toughened Glass door of Double Shutter width 750mm each in openable and 2 nos. 750mm width fixed shutter at both end with necessary Aluminium framework. 10MM thick toughened clear Glass held with Glass proper beading & gasket. Microprocessor-Biometric access controlled control unit, Lock, Inside release Button with memory storage Size 3.00MX2.40M, 2nos. Fixed & 2nos. Movable Shutter complete in all respect as per direction of Engineer in Charge. Note that:-1.The work should be executed by the Special Agency. 2. Shop Drawing will be submit & Taking approval From the Architect before execution. [ Access control instrument will be paid in ELV item Electrical]

34

-

-

... More
Providing and fixing unplisticsize Polyvinyl Chloride (uPVC) Rigid pressure pipes as per IS 4985:2000 and fitting, having thermal stability for hot & cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. for pump main from sewerage sump to discharge point as per direction of Engineer in Charge.

-

-

-

... More
VAV-04-LGF-F/ VAV-01-1F-D 3200 960

2

-

-

... More
2 Sets of 1000 A 4P ACBs 35 KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings.

-

-

-

... More
Providing & Fixing 4mm thick Float Glass for Vision panel for Flush Door including bead & all charges complete in all respect as per size & Design Shown in the Drawing as per direction of Engineer-in-charge.

328

-

-

... More
Incoming

-

-

-

... More
Supply of VC system like Codec, Camera and Microphone that should be from the same OEM.Full HD 1080p camera, codec, Microphone Array, cables, and remote control. It should support H.323, SIP standards for communications, H.261, H.263, H.264 AVC/ SVC, H.264 High Profile, 1080p 60 fps, 1080p 30 fps, 720p 60 fps and 720p 30fps, content sharing using standard based H.239 and BFCP over SIP at resolution HD1080p60, audio from PC used for content sharing, should transmit both people and content both simutaneously to the far end location at 1080p 30fps, should support G.711, G.728, G.729A, G.722, G.722.1, AAC-LD or better, 20kHz bandwidth with crystal clear audio and stereo sound.Automatic Gain Control and Automatic Noise Suppression. Keyboard noise reduction and instant adaptation echo cancellation. 1 x HD input for connecting main HD camera. 1 x HDMI input for connecting PC/Laptop to share HD content . 1 x Microphone Input(Support for minimum 2 mics). 1 x 3.5mm stereo line-in. 2 x HDMI output for connecting main monitor & second monitor. 1 x 3.5 mm stereo line-out. 1 x 10/100/1000 LAN port. 2 x USB 2.0 for software upgrade and connecting external devices. 1 x RS-232 mini-DIN 8-pin, should support 1080p60fps with 10x optical zoom and 65° field of view, PAN Range of +/-100°, and Tilt of +/-20°, H.323 and SIP bandwidth up to 6 Mbps, IPv4 and IPv6 support from day one, Auto Gatekeeper Discovery, IP Precedence, H.323 based Packet Lost Recovery, should support atleast 6 sites at 720p. Media Encryption (H.323, SIP): AES-128, AES-256.Authenticated access to admin menus, web interface and telnet API.Local account password policy configuration, H224/H.281, H.323 Annex Q, H.225, H.245, H.241, H.239, H.243, H.460, should support native Lync server integrations,Auto sensing power supply. 125VA @ 230V @ 60Hz as per directed by Engineer in Incharge..

2

-

-

... More
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).

792

-

-

... More
Type Of Control System :MICROPROCESSOR BASED DUPLEX SELECTIVE /FULL COLLECTIVE CONTROL WITH / WITHOUT ATTENDANT

-

-

-

... More
MV cable laying upto 25 sq.mm. in same trench without sand and cover:- Laying of one number additional PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of size not exceeding 25sq.mm direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as reruired, but excluding sand cushioning, protective covering.

1000

-

-

... More
Providing and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer exexcavation and re-filling etc as required.

300

-

-

... More
Providing and fixing preapproved Kota stone slabs of 20 mm thick semi polished in trader of steps with single piece with 20mm thick base of cement mortar 1 : 4 (1 cement : 4 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete with Single piece all lead & lift as specified and as directed by Engineer-in-charge.

2874

-

-

... More
1 Set of 3200/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Extra for providing vision panel in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured):For Rectangular or square

4

-

-

... More
For 150mm dia Pipe Class-II

108

-

-

... More
Supply, Installation, Testing & Commissioning of 8" Two-way full range loudspeaker; Woofer size : 8", Tweeter size : 1"; Low impedance : 8 Ω; Low impedance dynamic power : 300W; SPL 1W/1m : 90dB; Max SPL : 112dB Frequency response : 60 - 20K Hz; V X H dispersion @ 1KHz : 160° X 150°; Woofer cone material : Paper ; IP rating : 40 as per directed by Engineer in Incharge.;

16

-

-

... More
VAV-08-1F-C 5180 1554

1

-

-

... More
BEARING:-Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced lastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, complete assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRT&H Specifications complete as per drawing and approved technical specifications. b) For max. Horizontal force within 25% of the max. Vertical load as per the direction of Engineer-in-charge .

10000

-

-

... More
Filters - 1 Set

-

-

-

... More
6 Nos, 250 Amps TP MCCB, 50 KA, Thermomagnetic Protection controlled.

-

-

-

... More
VAV-03-LGF-G/04-LGF-G/05-LGF-G 3626 1088

3

-

-

... More
Supplying, installation, testing & commissioning of Optical Fiber MM Adapter (12Core, OM4) as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

252

-

-

... More
HRU Supply, installation, testing and commissioning of Heat Recovery Units comprising of Heat Recovery wheel having minimum 75% efficiency (with equal recovery of latent and sensible heat) supply air section with blowers and filter, return air section with blower and filter, concrete foundation/ Hanging arrangement with vibration isolator. VIbration isolatior should be selected in way that the machine vibration shall not transfer to the building structure, etc a required and as per the specifications of following capacity:- As Direction of E/C

-

-

-

... More
Vertical Inline Split Coupled pump.

-

-

-

... More
12 WAY (8+36), Double door, Vertical type (Lighting SDB)

122

-

-

... More
ACDB-02 AHU ROOM :-Supply, installation, testing and commissioning of following distribution boards totally enclosed compartmentalized, cubicle floor mounted, indoor type IP:42, factory fabricated with 2 mm thick sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply suitable for 25 KA as per specifications and drawings. All Air Circuit Breakers shall be provided with Micro processor based Earth fault, short circuit and over current releases. Moulded case circuit Breakers shall be microprocessor based electronic trip. Fault level for all ACB/MCCB and bus bar shall be 25 KA, all the motor feeder shall be type-2 coordinated. ICU shall be equal to ICS=100% As Direction of E/C

2

-

-

... More
3 C x 300 sq.mm

120

-

-

... More
Each unit shall be complete with powder coated electrical panel and double earthing. The cables should be Cross linked polythene insulated, armoured Copper cabling and all termination between main panel and PAC. Timers shall be provided in Electrical panel for delayed start of units.

-

-

-

... More
STAIRCASE PRESSURIZATION (i) 9860 CMH at SP at 15 mm WG

20

-

-

... More
Supply, Installation, Testing, & Commisioning of Manual Actuator Assembly complete with liver to activate the system manually. as per direction of Engineer in Charge.

48

-

-

... More
(ix) 1105 15

24

-

-

... More
(ix) 0-25 A Ammeter with ammeter selector switch & 25/5 CT's - 02 Sets.

-

-

-

... More
5 Sets of 1600 A 4P ACBs 50 KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings.

-

-

-

... More
Providing & fixing Aldrop SS material & SS finish 300mmx16mm with necessary nuts screw etc. for flush Door shutter of approved Make complete in all respect as per direction of Engineer in Charge.

447

-

-

... More
Providing, laying and fixing 80mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required as per directed by Engineeer in Charge(Note: Total Numbers of Earth Pits may vary as per soil resistivity test at site.)

-

-

-

... More
2x125 kVAr LT power capacitor banks with 1 No 100 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
Incoming

-

-

-

... More
(ii) 0-500 V Voltmeter with Voltmeter selector switch and control fuses - 1 Set

-

-

-

... More
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.5 mm thick (Century, Green Ply, Greenlam)

2620

-

-

... More
(b) ON / OFF / TRIP Indicating Lights with control fuses – 1 Set

-

-

-

... More
50mm dia

8

-

-

... More
(d) R, Y, B phase indicating LED light with 2A MCB - 1 set

-

-

-

... More
Outgoing

-

-

-

... More
7 no. 20A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Fan assembly shall be statically and dynamically balanced to G 2.5 grade as per ISO 1940.

-

-

-

... More
PROPELLER FAN:Supply, installation, testing and commissioning, of wall/window type exhaust propeller fan with mounting ring, arm, impeller, motor with class ‘B’ insulation, IP- 40 Motor, capacitor, support, pressed steel wall frame, vibration isolators, fixed type aluminium louvers with bird screen, nut bolts for use on 220/240 volts, single phase, 50 Hz, power supply with all accessories, ancillary work, Sound level should not exceed 36 dB(A) at 3m, epoxy powder coating etcas required and as per specifications. As Direction of E/C

-

-

-

... More
Type of Refrigerant: R134a / Ecofriendly Refrigerant

-

-

-

... More
Note: All metering current transformers shall be Class 0.5, 05 VA, cast resin type.

-

-

-

... More
Supplying and fixing Rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

232

-

-

... More
(b) ON / OFF / TRIP Indicating Lights with control fuses – 1 Set

-

-

-

... More
Under Voltage & Over Voltage protection with protection release.

-

-

-

... More
Supply a necessary number of caution boards such as "Man on Line" 'Don't switch on' etc. as required as per directed by Engineeer in Charge

4

-

-

... More
Supply and fixing of silencer cladding of 2250 KVA DG Set with 75mm thick mineral wool insulation of 96 Kg/ cu³ density over the silencer including cladding with aluminium sheet 26 SWG and covering from outside complete,as required as per directed by Engineeer in Charge..

2

-

-

... More
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.

79677

-

-

... More
1 Set of 250/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
VAV-04-2F-B 8495 2549

1

-

-

... More
VAV-06-GF-H 3860 1158

1

-

-

... More
(d) 40 mm nominal bore.

9.96

-

-

... More
SITC of 17.2 mm dia Copper bonded 250micron, UL listed & CPRI tested rod of 3 mtr length as per direction of Engineer-in-charge. SITC of Environment friendly, RoHS certified, low resistivity Ground Enhancement material in 22.6 Kg pack to fill the bore area around the rod as per direction of Engineer-in-charge.

168

-

-

... More
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. (Below False Ceiling areas).

5546

-

-

... More
Supply, Installation, Testing & Commissioning of 19", 6U/500MMD 1 SECN with front glass door cam lock,PDU 6x5Aamp and 1.5meter feed cable and 3 pin plug - 1 No. shelf - 1 Nos, Fan 203v 90 cfm - 2 Nos, cable manager 1Upvc loops - 2 Nos, Hardware pkt of 10 - 1 Nos

-

-

-

408

-

-

... More
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.(At any Level)

386828

-

-

... More
Granite of any colour and shade Area of slab over 0.50 sqm

10805

-

-

... More
VAV-05-2F-A 2325 698

1

-

-

... More
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).

92

-

-

... More
(i) 315 mm dia ≤ 1400 RPM, Sound level should not exceed 50 dB(A) at 3m

371

-

-

... More
(iv) 16 A TP MPCB - 03 No.

-

-

-

... More
VAV-09-2F-F 1170 351

1

-

-

... More
Dia 150mm - 2 No.

-

-

-

... More
(x) 0-16 A Ammeter with ammeter selector switch & 16/5 CT's - 4 Sets.

-

-

-

... More
65 mm nominal bore Horizontal

40

-

-

... More
1 no. 100A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design.(a) 1.68 m deep with SFRC cover and frame (Heavy duty HD 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.

96

-

-

... More
First Aid Box as approved by St. John. Ambulance Brigade/Indian Red Cross conforming to IS 2217-1963 as per directed by Engineeer in Charge.

2

-

-

... More
Incomer

-

-

-

... More
Chilled Water flow: 2730 LPM

-

-

-

... More
5 NO - R, Y, B Phase indicating lights (LED Type) with 2A, SP MCB, 10KA, "C" Curve

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100mm dia

600

-

-

... More
VAV-03-1F-E 2560 768

1

-

-

... More
Dia. 200 MM - Ultrasonic BTU Meter

-

-

-

... More
OUTDOOR PTZ BOX CAMERA WITH INTEGRATED IR Supply, Installation, Testing & Commissioning of Networkable,, High Performance, Outdoor Box Type PTZ Camera with external IR of 200 Mtrs with 1/2.8" progressive scan , 2 Megapixel ,4.3 -129 mm Lens, 2 simultaneous streams and one service stream , 60FPS, Sensitivity : Color 0.008 lux Mono 0.001 lux and 0.00 Lux with IR, True Day & night type , H.264 / Motion JPEG Video Compression, 1920 x 1080 , 130 WDR Must or Better ,30X Optical and 12x digital zoom, Three Automatic Defog, OptionsShutter Range 1/1 ~ 1/10,000 sec or Better,Vertical Tilt Unobstructed +40° to –90°, Pan Movement 360° continuous pan rotation, Variable Speed 0.1° to 140°, 3D Noise Filtering, Electronic Image Stabilization (EIS), Support Upto 2TB Edge Storage, Input Voltage HPoE, 24 VAC, 48 VDC / Mains 100 to 240 VAC,Operating Temperature –45° to 60°C, Housing, Connectors, Lens, and all mounting accessories with OEM warranty minimum 3 years as per the given detailed specifications. Near Boundary Walls and Parking Lot as directed by Engineer in Charge.

16

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, over the hard surface, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge

324

-

-

... More
(a) 63 A 4P MCCB – 1 No.

-

-

-

... More
Providing & fixing SS 304 Fire rated Pull handle D Type 19mmx300mm Length (For Fire Metal Door)

428

-

-

... More
Floor Display Char: As mentioned below

-

-

-

... More
(v) 1850 500 900

1

-

-

... More
(ii) 0-500 V Voltmeter with Voltmeter selector switch and control fuses - 1 Set

-

-

-

... More
Pipes, cables etc., not exceeding 80 mm dia.

14163.099

-

-

... More
DDC- 22

2

-

-

... More
(i) 630 A 4P MCCB - 04 No.

-

-

-

... More
(vi) HRU-1F-01- 1700 CMH Floor Mounted

1

-

-

... More
VAV-01-2F-D 1535 461

1

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Chemical with Anchor rod M16X190-200

4

-

-

... More
Supply, Installation, Testing & Commissioning of 3 Mtrs HDMI Cable : Crystal-clear video up to 4K DCI (4096 x 2160 @ 30Hz), 4K UHD (3840 x 2160 @ 30Hz), and 1080p @ 60Hz signal HDMI Ethernet Channel functionality: additional dedicated data channel supports networking HDMI (3D, Deep Color, 4K) and HDCP 2.2 compatible Gold-plated connectors for reliable transmissions 3 mtrs in Length, RoHS-compliant as per directed by Engineer in Charge

3

-

-

... More
VAV-02-1F-E 3005 902

1

-

-

... More
Kitchen sink with drain board. (i) 510mm x 1040mm bowl depth 250mm.

10

-

-

... More
(ii) 0-500 V Voltmeter with Voltmeter selector switch and control fuses - 1 Set

-

-

-

... More
3.5 C x300 sq mm A2XFY cable (70mm)

260

-

-

... More
VAV-03-2F-D /VAV-07-3F-G 1425 428

2

-

-

... More
Application of 13 mm thick UV Film laminated Nitrile foam class "O" insulation duly fixed with adhesive & sealed with imported black tape of 50 mm width for floor of Server Room.

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type) with smart sleek PVC dual flushing cistern 3/6 litres capacity, seat and lid, including flush pipe, with manually controlled device, overflow arrangement with all specials, fittings of standard make and mosquito proof coupling of approved municipal design complete, Hindware cat. no. 20011 & F850009 or equivalent make including painting of fittings and brackets, cutting and making good the walls and floors wherever required as per direction of Engineer In Change. : W.C. pan with ISI marked white solid plastic seat and lid.

545

-

-

... More
1 no. 250A 4P MCCB, 25 KA microprocessor controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
VAV-02-1F-C 5585 1676

1

-

-

... More
Bus Bar

-

-

-

... More
gun metal foot valve with necessary fittings complete as required 50 mm dia

4

-

-

... More
(f) 32 mm dia pipe

2400

-

-

... More
Supplying, laying, testing and commissioning of following sizes of Low Smoke Zero Halogen Silicon Insulated Fire Survival Cable with Drain Wire, solid copper conducter cable approved by LPCB as per BSEN 50200:2015 PH 120 (Fire, Mech Shock & Water 120 Minutes @ 830 deg Celcius, Fire & Mech Shock every 5 Min for 2 Hours- Both test conducted on same sample) and BS-6387 CWZ The cable shall sustain 950 deg. C. For 3 hours approved along with accessories/ termination glands and all necessary materials to complete. The cable shall be approved for. The cable shall be BS EN 60332-1-2:2004 for Bunched Flame Retardancy (installed as a single or bunched cable self extinguishes leaving the upper cable sheath unaffected showing the cable does not propagate fire). Cable shall be guaranteed for 10 years from the date of manufacture marked on the cable. as per direction of Engineer in Charge. Size :-2C X 1.5sqmm.

6930

-

-

... More
VAV-02-2F-D/05-3F-C/01-3F-F 3350 1005

3

-

-

... More
Supply of Recess LED 595 X 595mm fitting with Smart Pyramid Optics, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) =110lumens/watt (depending upon the dimlevel & CCT), Tunable White CCT from 3000K TO 6500K, Life of fixture 50000hrs@L70 Lumen maintenance, CRI 80, PF 0.95, an operating Voltage Range of 220V- 240V, Standard Deviation Colour Matching (SDCM) =3 to =5. Glare free with UGR19. The total Power Consumption should be within 50W to 60W (including DALI driver), Minimum system Lumens 6000lm@5000K (Depending on dim level and CCT). Philips Model RC464 LED80S/TWH PSD W60L60 VPC W or equiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification Required: LM 79 & LM 80 . Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

114

-

-

... More
(i) 16 A TP MPCB - 21 No.

-

-

-

... More
Supplying, installing, testing and commissioning of ceiling loudspeaker of minimum 4.25 inch driver and a 1 inch tweeter in a 2-way design with polypropylene woofer material and an IP rating of IP50, transformer with multiple taps of at least 30 - 15 - 7.5 - 3.75 watts at 100v and 30 - 15 - 7.5 - 3.75 - 1.75 watts at 70v, frequency response of at least 75 - 20KHz, dynamic power of at least 80 watts and the low impedance connection shall present a load of 16 ohms to the amplifier. The output SPL at 1m 1watt shall be at least 88 dB and maximum output SPL at 1m with full power shall be at least 108 dB. The loudspeaker shall include overload protection for failsafe operation as per directed by Engineer in Charge..

4

-

-

... More
Providing and laying non-pressure NP3 class R.C.C. pipes with spigot & Soket jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete as per direction of Engineer-in-charge::

-

-

-

... More
Supplying, installation, testing & commissioning of following sizes of MS pipes of specified thickness for exhaust system s per directed by Engineeer in Charge.

-

-

-

... More
(ii) Star Delta / DOL starter with ON/OFF indicating light, ON/OFF push buttons, control fuses, timers, contractors, overload relay with built-in single phase preventor, control fuses, wiring, interconnections suitable for following rating motor.

-

-

-

... More
MLP-01 (MAIN LIFT PANEL-01 ) ( ELECTRICAL ROOM LOWER GROUND FLOOR - EAST & WEST BLOCK) / MLP-02 (MAIN LIFT PANEL-02 ) ( ELECTRICAL ROOM LOWER GROUND FLOOR - EAST & WEST BLOCK) as per direction of Engineer-in-charge.

4

-

-

... More
Providing & Fixing privacy & decorative self adhesive Film upto 5mm thick frost over Vision panel as per Design & Pattern for Flush Door including all charges complete in all respect as per direction of Engineer-in-charge

328

-

-

... More
MAIN FEEDER PILLAR-1 : Incoming: 1 set of 400A,4-Pole, MCCB, 25 KA microprocessor based controlled with overload, short circuit and earth fault protection, 1 set of 400/5A CTs of 15VA burden, accuracy class - 0.5 for metering and class 5P10 protection with digital multifuntion meter along with 1set of R, Y, B, phase indicating lights (LED Type) with 2A, SP MCB, 10KA Outgoing : 63A 4P MCB, 10KA - 8Nos, 32A 4P MCB, 10KA - 6 Nos, 32A 2P MCB, 10KA - 3 Nos. Shop drawings shall be in the scope of bidder.

2

-

-

... More
1 no. 200A 4P MCCB, 25 KA Thermomagnetic controlled. with overload, short circuit and earth fault protections.

-

-

-

... More
100 mm width x 50 mm depth x 1.6 mm thickness

1708

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
20mm dia rebar at 500 mm depth

4

-

-

... More
VAV-03-GF-A 2850 855

1

-

-

... More
Providing & fixing Stainless Steel H-type Pull Handle with SS finish size as follows with necessary screw etc. for flush Door shutter of approved Make complete in all respect as per direction of Engineer in Charge. 600MM overall Length DIA 25MM

1285

-

-

... More
VAV-02-1F-A 1535 461

1

-

-

... More
Auxiliary contacts required for necessary interlocking of breakers.

-

-

-

... More
3 Nos. (2 W + 1 SB) Factory mounted Vertical Inline split coupled secondary chilled water pump centrifugal pumps set along with suction guides and complete with suitable HP, IE2 TEFC induction motor with class ‘F’ insulation, IP -55 protection, operating on 415±10% volts, 3 phase, 50 cycles AC supply for each pump with IP-55 motor mounted VFD of suitable rating.

-

-

-

... More
Supply and Termination of Fire Survival Cables, copper conductor as per BS 7846, XLPE Insulated, armoured, Halogen free Sheathed of 1.1KV grade as required. As Direction of E/C

-

-

-

... More
VAV-04-2F-C 3000 900

1

-

-

... More
Providing and laying D.I. Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Up to 600 mm dia quintal

604

-

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.

40

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
All 4 Pole ACBs should have 100% neutral rating

-

-

-

... More
Application of cover Geotextile of Roof Water Proofing:- Supply & application of 120 grams per sqm Geotextile membrane in sandwich form over the fully cured waterproofing membrane & over XPS insulation board double layer sandwich with suitable lapping joint and proper fixing arrangement complete in all respect as per the directions of Engineer-in-Charge. (Payment for each layer separately)

80724

-

-

... More
3 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(i) 0-630 Ammeter with Ammeter selector switch and 630/5 C.T.s -1 Set

-

-

-

... More
700 mm dia. R.C.C. pipe.

396

-

-

... More
Levelling Course Cement mortar 1:5 UPTO 25MM THICK :- Providing and laying in position Cement mortar 1:5 (1 cement : 5 coarse sand). curing, and finishing as per direction of the Engineer-in-charge.

3638

-

-

... More
Pump Minimum efficiency shall be 75%.

-

-

-

... More
Providing and fixing C.I Sluice Valves (With cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately)

-

-

-

... More
Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation frenches within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume). (Note:- Filling trench, plinth & surrounding area of trenches upto Ground Floor Level as per drawing, from excavated earth obtain from foundation trenches stacking beside foundation trenches)

244804

-

-

... More
50mm nominal outer dia. Pipes

539

-

-

... More
Control MCB - I Set

-

-

-

... More
2 Sets of 630/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
VAV-01-GF-H 2968 890

1

-

-

... More
1x37 kVAr LT power capacitor banks with 1 No. 30 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
Cooling Tower shall have controls based on wet bulb logic with variable speed drives to control the fan.

-

-

-

... More
Supply, installation, testing and commissioning of indoor type floor mounted metal clad, 11 KV VCB panel ,totally enclsoed & fully interlocked, horizotnal drawout, horizontal isolation type breaker as per IS 13118, as amended upto date and additional specificatios, having capacities as mentioned below, single break, trip free mechanism, manually closing motorised breaker suitable for use on 11 KV, 3-Phase, 50 Hz AC supply with short circuit fault level of 25 KA, complete with self-contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper busbars, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO + 4 NC and equipped with following switchgears and accessoreis including connection, XLPE 11 KV cable (cable entry from bottom) as per directed by Engineeer in Charge.

-

-

-

... More
3.5 C x 50 sq mm A2XFY cable (35mm)

68

-

-

... More
4 core 1.0 mm², PVC insulated, tinned copper conductor cable - shielded.

-

-

-

... More
1 nos. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including rilling holes in cubicle panel, making connections, etc. as required.630 A, 50 KA,TPMCCB (in Existing End feed Unit)

8

-

-

... More
Outgoing

-

-

-

... More
2250 KVA, 415 V Radiator cooled DG Set as per directed by Engineeer in Charge

6

-

-

... More
Earthing with copper earth plate 600mm x 600mm x 3 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal / coke and salt) as required.

30

-

-

... More
5 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(d) R, Y, B phase indicating LED light with 2A MCB - 1 set

-

-

-

... More
Outgoing

-

-

-

... More
Electric Supply :AC 400/440 VOLTS, 3 PHASE, 50 CYCLES

-

-

-

... More
Lot, Axially Split, Coupling, Coupling Guard, External type Mechanical Seal, Nut Bolts, Supports, Corrosion Resistant finish and all necessary accessories as required.

-

-

-

... More
Providing and laying 80mm thick reinforce factory made cement concrete interlocking Grass paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of compacted earth all complete as per the direction of Engineer-in-charge.

16572

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
Bus Bar

-

-

-

... More
Cooling tower inlet temperature: 36.4 °C

-

-

-

... More
b) 7.5 KW - 01 No.

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
20mm nominal bore

12

-

-

... More
600 mm width x 62.5 mm depth x 2.0 mm thickness

6

-

-

... More
VAV-02-2F-F 3015 905

1

-

-

... More
1 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in charge

20

-

-

... More
300 A, 415V, 4 strip, 25 KA, 50 Hz Aluminium Bus bar

-

-

-

... More
(v) 16 A TP MPCB - 06 No.

-

-

-

... More
EMERGENCY ITEMS :- (SUBJECT TO WRITTEN APPROVAL FROM THE ENGINEER IN CHARGE & PMC BEFORE EXECUTION OF THIS ITEMS) Providing & fixing HIT-RE500V3 or eqivalent of approved make with Threaded Chemical Anchor Rod of approved make complete in all respect as per direction of E/I.

-

-

-

... More
VAV-09-2F-B 1255 377

1

-

-

... More
Rocky strata including Boulders300 mm dia

1920

-

-

... More
3 Set of 800/5A CTs of 10 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc.

8561

-

-

... More
For 100 mm dia pipe

1450

-

-

... More
Test PB Yellow -Test Push Button with 1 NO Contact - 1 No.

-

-

-

... More
VAV-01-1F-B 4880 1464

1

-

-

... More
Outgoing

-

-

-

... More
TOILET SIGNAGE (Handicaped)

26

-

-

... More
Wall Finish :- Decoration as per Drawing & Design (Material paid in separate item )

-

-

-

... More
1 No. power factor digital meter 1 No. APFC relay Dual Source suitable for sequential operation of 13 Capacitor Banks

-

-

-

... More
Providing and fixing wash basin Hindware cat no. 10087 or equivalent with C.I. brackets, without 15 mm C.P. brass pillar taps / basin mixer but with 32 mm C.P. brass waste, 32 mm CP. Bottle trap and unions of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require as per direction of Engineer In Change: White Vitreous China Flat back wash basin size 550x400 mm.

355

-

-

... More
DDC- 20

2

-

-

... More
250mm diameter

2514

-

-

... More
Providing & fixing SS 304 Fire rated Ball Bearing But Hinges 100X 75X3MM,ss 304 (For Fire Metal Door)

1712

-

-

... More
VAV-02-LGF-F 3360 1008

1

-

-

... More
(iv) 300 mm width X 50 mm depth X 1.6 mm thickness

1600

-

-

... More
Supply, Installation, Testing and Commissioning of on line true parallel redundant suitable for providing power supply to computers/servers, delivery atleast 30 minute backup (For Parallel redundant UPS System 2 number battery banks each with 15 minute backup and suitable for incoming 415 volts, 3-phase +10 % - 15%, 50 Hz supply and three phase output voltage, including provision for , rectifier/dual converter, bypass switch, inverter, filter, Bypass & static transfer switch for automatic switch over, providing static bypass module, high switching frequency microprocessor based with built-in technical protections like short circuits, over load, high / low voltage cut off protection of load from source inclusive of bypass facility without giving any break of power, maintenance bypass switch, along with TVSS protection. Micro processor / software controlled annunciation, protection (including against input phase reversal), and menu run diagnostic module, associated cabling, connections, terminations, erection including associated foundation/ masonry or RCC work for mounting on base channels etc. complete as required and as per specifications. Supply, Installation, Testing and Commissioning of SMF battery banks suitable for following Parallel Redundant type UPS system 2/6 number battery banks each with 15 minute backup for Total 30 minute backup. as required. as per direction of Engineer-in-charge.

-

-

-

... More
(I) COOLING TOWER 2W+1SB Supply, installation, testing and commissioning of FRP induced draft, counter flow, cooling tower with Structural frame work each of following heat rejection capacity with FRP water basin, PVC fillings with integral louvers and high efficiency drift eliminatiors, hot water distribution by gravity complete with statically and dynamically balanced axial flow, Direct driven fans with IP 55, TEFC IE2 induction motor with Variable Frequency Drive and temperature sensor suitable for operation on 415±10% volts, 50 Hz. AC supply, suction screen, make up with float valve and quick fill arrangement, overflow and drain connections, suitable inspection ladder, access arrangement for cooling tower interior, concrete foundation, stainless steel hardware and steel supporting structure, anti-vibration mountings, Level sensor/switch, Each VFD panel shall be provided with digital display showing electrical parameters like Voltage, Current and Power Consumption & compatible enough to take these data on BMS. etc complete as required and as per specification As Direction of E/C

3

-

-

... More
Condenser Water Outlet Temperature: 36.4 deg. C

-

-

-

... More
(c) ON/OFF push button with control fuses – 1 Set

-

-

-

... More
(c) ON/OFF push button with control fuses – 1 Set

-

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C [Secondary Light Point (loop from above primary points without Switch)]

9248

-

-

... More
4 Nos. 630A, 25 KA for 3 sec. VCB

-

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
12mm dia rebar at 240 mm depth

4

-

-

... More
Third party BMS Compatibility: Hardware required

-

-

-

... More
Plywood with Veneer in partition Wall:- Design, Supply , Fabricate & Fixing 12mm thick plywood of moisture resistant & termiteproof (Lab Test certificate to be provided) ply of approved make (Century, Green ply, Kitply) over particle board with existing frame as base(Paid in separate item) at Dry Partition wall / Partition Wall for rigidly . Finished with Veneer (Decolam, Greenlam, Marino) pasted on plyboard for any side (eachside measure separately) duly french spirit polished complete in all respect as per Design and as per direction of Engineer in Charge. Location as per drawing. (SHOP DRAWING TO BE PROVIDED & DULY APPROVED BEFORE EXECUTION OF THE WORK).

846

-

-

... More
1 Set of 100/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
(a) 630 A 4P MCCB – 1 No.

-

-

-

... More
(a) 15 mm nominal bore.

1574

-

-

... More
DDC- 30

2

-

-

... More
1 Set of 320/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm

4200

-

-

... More
65 mm nominal inner dia .Pipes.

11

-

-

... More
3 Sets of R, Y, B Phase indicating lights (LED Type) with 2A, SP MCB, 10KA.

-

-

-

... More
Auxiliary contacts required for necessary interlocking of breakers.

-

-

-

... More
4 Strip aluminium bus bar of 1000 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 35 KA fault - 1 set

-

-

-

... More
Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Sandwich Type Rising Mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required

-

-

-

... More
(b) 100 mm nominal bore.

9638

-

-

... More
A): Discharge capacity 15 cum per hour at a pumping head of approx. 50 meters head (for sinking in Bore well approx. 200mm dia) with all accessories as required.

6

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. / PVC pipes including bed concrete as per standard design as directed by Engineer in Charge: 300 mm diameter S.W./PVC pipe

834

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Over speed indication

-

-

-

... More
Providing and fixing C.P on brass Sink Cock with swinging casted round shape spout (Wall mounted model) and wall flange, {Jaquar, Clarion (Quarter Turn), Cat. No. CQT - CHR - 23347 or approved equivalent} as per direction of Engineer in Charge.

12

-

-

... More
(a) Supply installation testing and comissioning of Pressure relief dampers manufactured from Aluminium extrusions with blade pivot mechanism incorporates nylon bushes and stainless-steel pins. The damper shall be selected for following size pressure rating as per specifications. As Direction of E/C

-

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
(i) 200 A, 415V, 3ph, 4 wire Aluminium busbar

-

-

-

... More
Minmum requirement of PC with Core 2 Duo processor, 250 GB HDD, 2 GB RAM, DVD Writer, Optical Mouse, Multimedia Key Board, 21" LED Monitor with Licensed Windows Operating System or latest latest updated available hardware and software at the time of purchase.

-

-

-

... More
(i) 1000 A, 415V, 3ph, 4 wire Aluminium busbar

-

-

-

... More
Supply, Installation, Testing and Commissioning of LED based suspended standalone linear (4ft) Luminaire with extruded aluminium housing, anodized silver finish. System lumen output of 3300(±10%) lumens and a minimum system efficacy of 110 lm/W.The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 5700k or 6500K, CRI80 and Standard Deviation Colour Matching (SDCM) =3 to =5. THe total Power Consumption should be with in 20W to 36W (including driver).Similar to Philips Make PureLine Tapered "SP810P LED26S-6500 PSU W6L120 OD " or eqiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification: LM 79 & LM 80 Certificates . Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

443

-

-

... More
Unit should be designed to deliver actual capacity at inside temperature of 22±1.5 °C & RH 50 ± 10% 42 °C Ambinet DB Temperature and 28 °C WB.

-

-

-

... More
PANEL+ HARDWARE

-

-

-

... More
4 Strip aluminium bus bar of 150 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
(iii) AH-LGF-06** 16 13900 4

1

-

-

... More
90mm OD Class 6(PN)

160

-

-

2

-

-

... More
Design, supply fabricate and fixing Semi Utilized Structural Glazing system with double (DGU) /single glazing for Door portion securely bonded to framework to ensure absolute water tightness, with profile either straight or segmented curve in plan consisting of main panel work of Mullions and Transoms made out of specially designed extruded aluminium section having 15-20 Microns Anodized in approved colour. Fixed at all levels, elevation and heights to the RCC elements with necessary clamps,brackets and anchor fasteners, made of shall be Mild steel Hot Dip galvanized with washer and shall confirm to IS : 4759 -1996. All gaskets shall be EPDM with all necessary flashing, floor seal, smoke seal, sealants etc. to make system fully weather and sound proof & water tight. Proposed glazing should be bonded to frame by mean of Structural sealant of Dow cornice995 and weather sealant shall be Dow Cornice 789. All spacer tape should be Norton or equivalent etc. complete with fixing Glass as per direction of the Engineer in Charge , inclusive of all except supply of Glass will be paid separately.(Glass fixing charges, Shutter Hardware of approved quality included in this item) (b) For Vision or Openable Area

4126

-

-

... More
Bus Bar

-

-

-

... More
Emergency Stop PB Mushroom Red - 1 NO

-

-

-

... More
65mm nominal bore

24

-

-

... More
Providing and fixing Copper wire Netting fixed with threaded / clamped connection to vent / overflow pipes upto the following dia ( Pipes to be paid separately) as per direction of Engineer-in-charge. (i) Upto 100 mm dia.

40

-

-

... More
SUB FEEDER PILLAR (For Street Light) : Supply, installation, testing & commissioning of factory fabricated feeder pillar comprising of the following for street lighting shall be moisture, dust & vermin proof, double door, compartmentalised suitable for floor mounting complete with aluminium bus bars, incomer with MCCB and outgoing with MCB,contactor,Timer,provisions for earthing, painting, canopy, etc. complete as required as per specifications and approved drawings. Cost of foundation to be included.The Feeder Pillar shall be provided with 24 hour cyclic timer (Latitude -23.3500 deg. N & Longitude -85.3300 deg. E at Ranchi,Jharkhand) along with control lead to be mounted within the panel. The timer shall be capable of energising rated TPN contactor. Incoming: 32 A 4P MCCB - 1 No. 3 nos single phase timer with battery back-up similar to legrand cat.no. or equivalent. 32 A 4P Contactor - 1 No. Busbar-50A,415V, 3-ph. 4Wire, 25KA for 1Sec, Aluminium Busbar. Outgoing : 16A 4P MCB - 4 Nos,16A 2P MCB - 4 Nos. Shop drawings shall be in the scope of bidder.

8

-

-

... More
(c) ON/OFF push button with control fuses – 1 Set

-

-

-

... More
Supplying, installation, testing & commissioning of MM LC Optical Fiber Pigtail (OM4) as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

1488

-

-

... More
m) Call barring

-

-

-

... More
Add 1% Labour Cess (in Basic Rate must fill 1)

1

-

-

... More
Auxiliary/MCC Panel for DG set accessories

-

-

-

... More
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats

436909

-

-

... More
2 X 16 sq. mm + 1 X 6 sq. mm earth wire

16188

-

-

... More
VAV-05-1F-G 1580 474

1

-

-

... More
(b) 20 mm nominal bore.

165

-

-

... More
VAV-07-2F-B 4320 1296

1

-

-

... More
a) 0.55 KW Motor - 06 No.

-

-

-

... More
1 Set of 250/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
4 Strip aluminium bus bar of 150 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
(xiv) AH-GF-07 15 11800 4

1

-

-

... More
(a) 300 A 4P MCCB – 1 No.

-

-

-

... More
Supply, Installation, Testing & Commissioning of 19", 6U/500MMD 1 SECN with front glass door cam lock as directed by Engineer in Charge, a] PDU 6x5Aamp and 1.5meter feed cable and 3 pin plug - 1 No b] shelf 255m - 1 No c] Fan 203v 90 cfm - 2 No, d] cable manager 1U pvc loops - 2 No e] Hardware pkt of 10 - 1 No

44

-

-

... More
2 no. 63A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Under Voltage & Over Voltage protection with protection release.

-

-

-

... More
4 Sets of 32A 4P MCBs, 10KA

-

-

-

... More
(i) 450 A, 415V, 3ph, 4 wire Aluminium busbar

-

-

-

... More
PVC Cu. 6 Sq. mm - 1 Set

-

-

-

... More
Supply, Installation, Testing, & Commisioning ofMaster Cylinder Kit complete comprises of Electric Control Head operated electrically from the detection and control system or locally with a manual actuator, complete with cylinder supervisory switch. as per direction of Engineer in Charge.

48

-

-

... More
2 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
Supplying, fitting and fixing C.P on brass Pillar Cock with Aerator, {Jaquar, Clarion (Quarter Turn), Cat. No. CQT - CHR - 23011 or approved equivalent} as per direction of Engineer in Charge.

725

-

-

... More
Providing and fixing G.I. tape 25 mm X 3 mm thick on surface of wall for complete as required. as required. as per direction of Engineer-in-charge.

4548

-

-

... More
VAV-04-GF-D 2590 777

1

-

-

... More
40 MMX 40MM

2500

-

-

... More
2 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(c) ON/OFF push button with control fuses – 1 Set

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

16424

-

-

... More
4 Strip aluminium bus bar of 1000 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 35 KA fault - 1 set

-

-

-

... More
VAV-04-GF-F 1054 316

1

-

-

... More
Shunt trip coil. - 1 Set

-

-

-

... More
150 mm dial type pressure gauges for suction and discharge of each pump.

-

-

-

... More
Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.

960

-

-

... More
Supply installation Testing and comissioning of Aviation Light & Lighting Arrestor alongwith earthing arrangement required for MS structure of 30 M height as per directed by Engineeer in Charge.

2

-

-

... More
DDC- 12

2

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

4

-

-

... More
HI WALL SPLIT UNIT:-Supply, installation, testing and commissioning of Hi wall type split AC direct expansion indoor units of following capacities complete with evaporator, condenser, cooling coil, condenser coil, fans, hermetically sealed compressor, control wiring, Refrigerant pipe with insulation, remote control unit, suitable automatic voltage stabiliser(s) with high/low voltage cut-out and time delay relay, insulated GI/UPVC condensate drain piping, unit mounting stands requisite power and control cable etc.as per specification and drawings. As Direction of E/C (i) 2.5 TR ( Minimum 3 Star)

2

-

-

... More
Including packing, ocean freight,insurance

-

-

-

... More
1 No. Surge Suppressor Type-2 as per specification

-

-

-

... More
Third party BMS Compatibility: Software required

-

-

-

... More
VAV-03-2F-H 2510 753

1

-

-

... More
VAV-03-3F-A 3910 1173

1

-

-

... More
DDC- 47

2

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. [Submain Wiring for SDB Shall be recessed and shall not be taken on Surface.]

-

-

-

... More
25mm nominal outer dia. Pipes

2024

-

-

... More
Bus Bar

-

-

-

... More
MAIN LT PANEL as per directed by Engineeer in Charge.

2

-

-

... More
Flow - 3420 LPM

-

-

-

... More
Note: All metering current transformers shall be Class 0.5, 05 VA, cast resin type.

-

-

-

... More
Lot, frame work for mounting the above condensing unit as per manufacturer installation detail.

-

-

-

... More
VAV-07-3F-C / VAV-05-3F-G 4260 1278

2

-

-

... More
KITCHEN DRY SCRUBBER:-Supply, installation, testing and commissioning of Electrostatic type Kitchen Exhaust Air Cleaner ( Dry Scrubber) complete with following accessories, componenets, foundations etc. as required & making it completely functional & suitable for kitchen hood exhaust. As Direction of E/C

-

-

-

... More
Supplying, fitting and fixing Wrought iron flange of approved quality, with washers and bolts as per standard joints complete in all respects as per direction of Engineer in Charge.

-

-

-

... More
(e) 50 mm Weight not less than 1.0 Kg.

12

-

-

... More
2-Way 'On/Off' Spring return type Motorized Butterfly Valves rated for 16 Kg/Sqcm with actuator & position feed back suitable for open / close operation to be installed in Chiller & condenser outlets. It shall be suitable installation outdoor on terrace with IP enclosure & suitable for 24V power supply. The price quoted shall include companion flanges and suitable PUF insulation + 10 mil glass clothing cladding to avoid condensation. No insulation on condeser valves is required.

-

-

-

... More
(c) 32 mm and weight not less than 700 gms

24

-

-

... More
(c) 32 mm nominal bore.

20.6

-

-

... More
Under Voltage & Over Voltage protection with protection release.

-

-

-

... More
(ii) AH-LGF-04 8 7750 4

1

-

-

... More
7. Any error in totaling in the amount column and in carrying forward total shall be corrected. Any error, in description or in quantity, omission of items from this Schedule shall not vitiate this Contract but shall be corrected and deemed to be variation required by the Services Consultant/Project Manager.

-

-

-

... More
Supplying, installing, testing and commissioning of 2x2 Full HD Video Wall considering 55” IPS, LED, FHD panel, Hard coating, Anti-glare surface treatment , Bezel Width: Less than 1 mm (L/T/R/B) even bezel , Brightness: 500 cd/m2 or higher, Dynamic CR: 500000:1, Built in system - 1.2Gzh Quad Core CPU, 550MHz GPU, 2.5GBDDR3 RAM & 8GB storage or higher, SRC, Typical Power Consumption 150W or less per panel, atleast 15x15 Tile Mode, Weight per panel not more than 26KG, USB Cloning.as per directed by Engineer in Charge

1

-

-

... More
100 mm nominal bore.

356

-

-

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm x 60 cm at the bottom and 50 mm x 50 mm at the top with a thickness of 10 cm including inscription duly engraved as required.

60

-

-

... More
Bus Bar

-

-

-

... More
It should have Simulator to simulate and review the customized GUI before uploading; it Support Scheduling for repeating events ; it Support Two-way communication enables user-defined event monitoring to automatically trigger the next actions ;It should have Simple profile setup with easy configuration steps via intuitive GUI.it should Allows administrators central control of multiple rooms via profiles on a mobile device or tablet computer. ; it should Max. No. Allowed 10 licenses.it support Any iOS, Android, or Windows mobile device can be used to control the system – no need to purchase costly exclusive user panels ; it should Restrict user access to profiles via password authentication; it should Synchronization of system controls amongst multiple mobile devices and tablet computers. 'It should have LED indication of connection and hardware status ;It should be Rack Mountable; It should support Operating Temperature 0-50°C. Storage Temperature -20 - 60°C. Humidity 0 - 80% RH, Non-Condensing; It should support I/P rating 100-240 VAC; 50-60 Hz; Power Consumption 40W.

-

-

-

... More
3 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
(i) 350mm dia

10

-

-

... More
Supplying, installing, testing & commissioning of M. S. Tank 30 K.L. capacity fabricated of out 6 mm thick M.S. plate complete with stiffner angles on side & centre and all standard mountings like manhole of 600 mm dia cover duly hinged, access ladders, lifting lugs, level transducer, earthing boss etc. Dish ends of 10 mm thick M.S. sheet, fuel filling nozzle of 80 mm dia, vent pipe of 40mm dia 4500mm long, suction & return nozzle pipe, Brass dip stick with calibration as per IS Code 10987 - 1992 (Tank fabricated from MS sheet conforming to relevant IS code). The tank shall be duly painted with one coats of primer & two of coats of 85/25 grade bitumen paints outside of tank (shalimar make) and tank shall be pressure tested at a pressure of 0.5kg/sqcm with water as per IS 10987 The rates quoted shall be complete with connected civil work including excavation, brick work concrete foundation as required, completes with foundation bolts, grouting, sand fill, disposal of surplus earth, debris as required for installation of tank including fire extinguishers & sand buckets as per requirement, fencing 1.8mtr heigh, earthing etc. as per requirement of explosive department, liasioning with concerned Govt. Authorities and NOC from Explosive department shall be contractors responsibility as per directed by Engineeer in Charge.

2

-

-

... More
(i) 3300 CMH, SP- 10 mm WG (for UPS/Battery room exh.)

2

-

-

... More
(i) 40 A TP MPCB - 02 No.

-

-

-

... More
VAV-05-2F-D 2740 822

1

-

-

... More
6 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(i) 16500 CMH at SP at 15 mm WG ( Minimum Efficiency - 60%)

2

-

-

... More
(xxvi) AH-2F-02* 22 19300 4

1

-

-

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585, 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. (a) 40m

146

-

-

... More
2 C x 4 sq mm A2XFY cable

400

-

-

... More
Supply, Installation, Testing and Commissioning of LED Recessed Downlighter with pressure die cast housing. Nominal system lumen output of 1500 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a CCT 5700k or 6500k, CRI 80, PF 0.95, an operating Voltage Range of 220V- 240V, Standard Deviation Colour Matching (SDCM) =3 to =5. The luminaire shall meet IP20 rating with THD10% and PF 0.9. The luminaire housing should made of pressure die cast aluminium .The total Power Consumption should be within 12W to 16W (including DALI driver).Similar to Philips Make GREENPERFORM SLEEK "DN 394B LED16S-6500 PSD WH" or eqiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification Required: LM 79 & LM 80 . Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

2714

-

-

... More
Extra for earthwork in hard soil as per specification and direction of E/I(vide classification of soil item-B)

76590

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
(vi) 29350

1

-

-

... More
DOOR HARDWARE FOR FLUSH / FRP DOOR ALL THE HARDWARE SHOULD BE APPROVED MAKE & DESIGN. RATES ARE INCLUSIVE OF NUTS, SCREW ETC.

-

-

-

... More
For 100mm dia Pipe

16

-

-

... More
Head – 30 M

-

-

-

... More
VAV-05-1F-F 4175 1253

1

-

-

... More
Pot Strainer 80 mm dia

2

-

-

... More
8 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(c) 40 mm nominal bore.

12

-

-

... More
Under voltage relay

-

-

-

... More
1. Load / Speed:26 Persons (1768Kgs.) / minimum 1.00 Mtr. Per Second 2. Total Travel distance: (4.5+4.5+4.5)13.5metre 3.Machine Room:-YES. 4.Floor Display Char: LGF,GF,1ST,2ND 5.Number of Landing Entrances: Four 6.Size of Lift Well: 2450X 3000 (MM Wide X MM Depth) 7. Flooring:-Black studded rubber flooring or with smooth PVC flooring

4

-

-

... More
2 No. Differential pressure sensors / transmitters not required in case of sensor less.

-

-

-

... More
For Kitchen Exhust :Supply, fabrication and erection of following gauges of MS ducting complete with welded drip proof seams and having access doors at every change in direction with maximum spacing of 6 meters in horizontal direction and maximun of 5 meters in vertical risers & elbows spliters, supports/suspenders bends, tees, vanes, Grease filter, double canvas connection of the equipment etc all complete as required and as per specificaiton. The duct shall be insulated with 50 mm high temperature fiber glass/Rock wool insulation with all serviice jacket. As Direction of E/C

-

-

-

... More
1 No. 40 Amps TP MCCB,50 KA, Thermomagnetic Protection controlled.

-

-

-

... More
4 Strip aluminium bus bar of 500 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
3 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Providing and fixing 80mm G.I. pipes complete with G.I. fittings including trenching and refilling etc. with all fittings from pump delivery to drain out point.

18

-

-

... More
(xi) Dia 40mm

31

-

-

... More
b) 450 mm dia. R.C.C. NP3 pipe

1146

-

-

... More
Master Control Unit with Audio Visual Alarm With Wiring to Make Complete System Operational. The Control Panel Should have Provision for integration with Fire Alarm/ SCADA/ BMS System. as per direction of Engineer in Charge.

128

-

-

... More
1. Load / Speed:26 Persons (1768Kgs.) / minimum 1.00 Mtr. Per Second. 2. Total Travel distance: (4.5+4.5+4.5+4.5) 18metre . 3.Machine Room:-YES. 4.Floor Display Char: LGF,GF,1ST,2ND & 3RD 5.Number of Landing Entrances: Five 6.Size of Lift Well: 2550X 2450 (MM Wide X MM Depth)

4

-

-

... More
Supply, Installation, Testing & Commissioning of Video Extender: It should Extends the distance between HDMI source and HDMI display It should Implements HD Base T - Lite extension technology using only one Cat 5 cable to connect the transmitter and receiver. It should be HDMI (3D, Deep Color, 4kx2k); HDCP Compatible. It should support Long distance transmission - up to 70m. It should Supports resolutions of up to Ultra HD 4kx2k and 1080p Full HD. It should selects the optimum EDID settings for smooth power-up and highest quality display. It should Supports up to 340MHz bandwidth for high performance video. It should Supports Dolby True HD and DTS HD Master Audio. It should have Max. Data Rate 10.2 Gbps (3.4 Gbps Per Lane). It should support Max. Resolutions / Distance Up to Up to 4K@35m (Cat 5e/6) / 40m (Cat 6a/Cat6); 1080p@60m (Cat 5e/6) / 70m (Cat 6a/ Cat6). It should support Operating Temperature 0 - 50°C. It should have support Temperature -20 - 60°C.It should have support 0 - 80% RH, Non-Condensing as per directed by Engineer in Charge

1

-

-

... More
Under Voltage & Over Voltage protection with protection release.

-

-

-

... More
Incoming

-

-

-

... More
LMDB-FF (LIGHTING MAIN DISTRIBUTION BOARD) ( FIRST FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 1 as per direction of Engineer-in-charge.

2

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
SITC of 8mm / 50 mm², AlMgSi, semi-rigid Round conductor complied to DIN EN 62561-2 (VDE 0185 Part 202), tesnsile strength 120-280N/MM2 & Environmental test for use as air-termination system,as specified in drawing and confirming to IS/IEC 62305 as per direction of Engineer-in-charge

4600

-

-

... More
(xi) AH-GF-02 11 10050 4

1

-

-

... More
(viii) Star Delta / DOL starter with ON/OFF indicating light, ON/OFF push buttons, control fuses, timers, contractors, overload relay with built-in single phase preventor, control fuses, wiring, interconnections suitable for following rating motor.

-

-

-

... More
4 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
c). Digital PRI line: 25 nos.

-

-

-

... More
LIFT NO.25 & 26/ 27 & 28 (VIP LIFT) Group of 2 No. Car as per directed by Engineeer in Charge.

-

-

-

... More
• Operating temperature: -20°-+70° C

-

-

-

... More
300 A, 415V, 4 strip, 25 KA, 50 Hz Aluminium Bus bar

-

-

-

... More
VAV-04-2F-D 2625 788

1

-

-

... More
(xxxii) AH-3F-04 11 10200 4

1

-

-

... More
Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using tructural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete

48782.83

-

-

... More
Shunt trip coil. - 2 Sets

-

-

-

... More
Bus Bar

-

-

-

... More
Chiller shall be AHRI certified

-

-

-

... More
32mm nominal bore

22

-

-

... More
3.5 C x 240 sq mm A2XFY cable (62mm)

68

-

-

... More
5 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(i) 41.9 mm

13

-

-

... More
12 no. 63A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
1 no. 320A 4P MCCB, 25 KA microprocessor controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
(vi) HRU-GF-07- 1600 CMH Ceiling Suspended

1

-

-

... More
Supply,Installation,Testing and Commissioning of Factory-packaged Water cooled liquid chillers with UL Listed / Certified Motor, VSD driven motor suitable for 415±10% volts, 50 cycles, AC supply, ASME/GB stamped shell & tube Condenser, Evaporator, suction, discharge valves, relief valve, Oil filter, suction filter, muffler, safety switch & pressure relief valves, low flow Flooded chillers complete with anti-freeze thermostat, cooling thermostat, Variable orifice or electronic expansion valves, liquid line strainers, shut-off valves, cooler/evaporator with nitrile rubber or equivalent insulation with 24 G aluminium cladding, interconnecting refrigerant piping, fittings, suction line insulation. Pre-wired control system including automatic & safety controls with microprocessor based control panel, flow sensors at chiller & condenser, display and key pad, oil heater and service valves, automatic oil return system, all interconnecting unit piping, Vibration Isolator, Victaulic coupling and matching flanges, all interconnecting unit control and power wiring, starter panel, provision for refrigerant and oil charge, Refrigerant isolation valve & all necessary accessories as per relevant std. All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with acrylic paint. Chiller RCC foundation with Vibration Isolators etc. as required. All other parameters as per the technical specifications given in the tender. 2W+1SB

3

-

-

... More
Supply, Installing, testing and commissioning of 24-port PoE+, 4 x 10G with 5 year warranty as per directed by Engineer in Chargeb Supply, Installing, testing and commissioning of license of the POE switch(Already bundled with the switch) as per directed by Engineer in Charge

60

-

-

... More
Plywood Veneer:- Providing and Fixing Wooden false Ceiling at all height comprising of necessary hard wood frame antitermite treated as required covered with IS 1328 BWR Type termite proof Plywood 12 mm thick finished with a veneer 4mm (as approved) pasting with glue duly French Spirit polished with melamine matt coating as per Drawing & Design. The frame shall be fixed at proper level & line with adequate suspenders & necessary fixture complete in all respect as per direction of Engineer in Charge. FALSE CELING :- A special agency of sufficient credential duly approved from the architect & the Engineer in Charge before execution the Interior Work.(Shop drawing should be approved by the Architect before execution of the work)

95

-

-

... More
25mm nominal bore

2

-

-

... More
VAV-03-2F-D 3495 1049

1

-

-

... More
(f) 50 mm nominal bore.

1875

-

-

... More
600 mm width x 62.5 mm depth x 2.0 mm thickness

2060

-

-

... More
supply air grilles with in accordance with the approved shop drawings along with VCD

-

-

-

... More
Supplying and laying 50 mm X 6 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection / terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) as per directed by Engineeer in Charge (For HT And LT Panel Body Earthing )

820

-

-

... More
Providing & fixing Surface Hydraulic door closer with adjustable arm for Wooden Flush door Shutter weight 80 TO 120 Kg, with necessary fixture of approved make & design complete in all respect as per direction of Engineer in Charge. Material SS304 & SS finish

2172

-

-

... More
20mm dia

302

-

-

... More
(iii) 450 mm dia ≤ 1400 RPM, Sound level should not exceed 60 dB(A) at 3m

20

-

-

... More
195 mm x 50 mm

560

-

-

... More
2 Sets ON / OFF / TRIP indicating lights with SP MCB’s.

-

-

-

... More
(h) 100 mm nominal bore.

2

-

-

... More
450 mm dia. R.C.C. pipe.

812

-

-

... More
Fabric Panelling:-Designing , Supplying & fixing Fabric of design & colour Panelling fixed in interior wall / Partition wall /Dry Partition wall on specified area fixed over alumium frame of required section as per Shop drawing duly approved complete in all respect as per direction of Engineer in Incharge ay any level.

709

-

-

... More
(c) ON/OFF push button with control fuses – 1 Set

-

-

-

... More
Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477,in average 3mm thickness.

40

-

-

... More
DDC- 29

2

-

-

... More
Bus Bar

-

-

-

... More
a) 30800 CMH at SP at 20 mm WG

2

-

-

... More
VAV-03-2F-H 1515 455

1

-

-

... More
3 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Compressor enclosure: Semi Hermetic

-

-

-

... More
(i) AH-LGF-01 22.4 22500 4

4

-

-

... More
1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
VAV-07-GF-H 2200 660

1

-

-

... More
UPS SFDB- (UPS SUB FLOOR DISTRIBUTION BOARD ) ( MAIN ELECTRICAL ROOM ) as per direction of Engineer-in-charge

2

-

-

... More
Bus Bar

-

-

-

... More
(a) 200 A 4P MCCB – 1 No.

-

-

-

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

7312

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : for chlorination chambers. 15 mm nominal bore

16

-

-

... More
e) 200 mm dia - MS 10 mm thick pipe. (Welded/Flanged Joints)

3586

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of LSZH insulated copper conductor, single core cable in surface/ recessed steel conduit as required.and directed by Engineer in Charge

-

-

-

... More
7 no. 40A 4P MCCB, 25 KA Thermomagnetic controlled.

-

-

-

... More
VAV-01/02/03-GF-F 3600 1080

3

-

-

... More
Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof.

8858

-

-

... More
f). RJ 45 LAN port for system administration via TCP/IP & for CTI and CSTA protocol,

-

-

-

... More
(vi) R,Y,B indication LED light with 2A MCB - 1 Set

-

-

-

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.

100

-

-

... More
1 No. power factor digital meter 1 No. APFC relay Dual Source suitable for sequential operation of 7 Capacitor Banks

-

-

-

... More
POWER SUPPLY

-

-

-

... More
(xi) 0-10 A Ammeter with ammeter selector switch & 10/5 CT's - 08 Sets.

-

-

-

... More
Supplying, fitting and fixing C.P. brass Two way Bib cock, Cat. No. CQT - CHR - 23041 or approved equivalent} including cutting and making good the walls wherever required as per direction of Engineer In Change.

595

-

-

... More
25 MMX 40MM

2500

-

-

... More
1 Set of 100/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
VAV-06-2F-H 1460 438

1

-

-

... More
(xv) 0-6 A Ammeter with ammeter selector switch & 6/5 CT's - 04 Sets.

-

-

-

... More
3.5 C x 70 sq mm A2XFY cable

1321.12

-

-

... More
Supply of following size cross -linke polyethylene (XLPE) insulated, FRLS PVC outer sheated with galvanized round steel strip, with Al. conductor suitable for rated voltage of 1100 volts grade & conforming to IS:1554 (Part-I) 1988 amended up to date.(Compulsory ISI marked) LT CABLS

-

-

-

... More
VAV-03-1F-G 2405 722

1

-

-

... More
(xxiv) AH-1F-08 22 18500 4

1

-

-

... More
Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket.

-

-

-

... More
40 amps

10

-

-

... More
EXIT SIGNAGE (Double Side)

56

-

-

... More
(x) 1870 15

4

-

-

... More
Supplying, installing, testing and commissioning of a wireless digital desktop delegate conference unit connecting to the conference system via the antenna module, operating in 2.4 GHz and the 5 GHz frequency band, built-in PCB antennas with pattern diversity and a coverage area of 30 m (100 ft) radius, adjustable RF output power from 25 to 100 mW, 128-bit AES encryption, rechargeable battery pack with an operating time of more than 20 hours, microphone key with a bicolor LED ring for microphone status indication functioning as on/off switch or as a request-to-speak button, high-performance broadband twin loudspeaker system with frequency response of 100 Hz to 14.5 kHz, integrated DSP limiter to protect against excessive input signals, option to connect super-cardioid gooseneck microphone, 3.5 mm headphone socket and a headphone volume control with headphone output level of minimum 50 mW / 16, THD (at 1 kHz) shall be 0.03 % at 50 mW / 16, Signal-to-noise ratio 70 dB(A) as per directed by Engineer in Charge.

6

-

-

... More
5 no. 40A DP MCCB,Thermomagnetic controlled.

-

-

-

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

2387

-

-

... More
One set of R.Y.B. indication lights with toggle switches & Protection M.C.Bs.

-

-

-

... More
40 amps, DP

120

-

-

... More
VAV-02-2F-C 4780 1434

1

-

-

... More
Supply, Installation, Testing and Commissioning of SMD LED Flood Light with minimum 22500 Lumens (at system level ) with C clamp mounting and LM6 Pressure die cast housing with High efficiency Glass cover,Lens PMMA , Impact resistance IK 05, The total Power Consumption should be within 200W to 230W (including driver), Driver Efficacy : 90% , Life L70 , 50K Hrs , color temp : Cool white , Luminaire efficacy 100 lumen/Watt at system level, LED Drive Current : Not more than 750 mA and should be of single current rating (option for variation of drive current through hardware/switches is not required), Junction temperature (Tj): at the soldering point should not exceed 55 degree C + 10% over an ambient temperature of 25degree C, Heat dissipation / heat sink : Well designed Thermal management system with PDC Aluminum heat sink, Gravity die cast shall not be accepted, Electrical safety & Conformation standards of luminaire : The luminaire conform to IEC 60598. CJJ 45-2006, CIE--BS EN 13201-2:2003, RP-8)& Photobiological Safety report is required, graduation disk for aiming, LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Similar to Philips BVP410 LED 225 CW HE SY20 FG S4 XTFCL or equiv. Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

44

-

-

... More
VAV-06-3F-G 06/3F-A/07-3F-A 1550 465

3

-

-

... More
3.5 C x 35 sq mm A2XFY cable (32mm)

8

-

-

... More
Supplying and laying 32 mm X 6 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm). as required. as per direction of Engineer-in-charge.

180

-

-

... More
Providing & fixing Door buffer SS material body & finish to protect from wall hit with necessary screw etc. for flush Door shutter of approved Make complete in all respect as per direction of Engineer in Charge.

1290

-

-

... More
3 Sets of 100A 4P MCCBs, 25KA

-

-

-

... More
Supplying and laying 50 mm X 6 mm G.I strip on surface or in recess as earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) as per directed by Engineeer in Charge (Pump Room - Service Building I)

440

-

-

... More
Supply, installation, testing and commissioning of duct mounted Explosion Proof Inline fan complete with direct driven centrifugal fan, TEFC squirrel cage induction motor, direct drive arrangement, heavy gauge sheet metal casing, rubber isolator mounts and other accessories, Hydrogen Sensor, cables, etc. as per specification and as required. As per Direction of E/I

-

-

-

... More
LIGHT FITTING :- Numbering of ceiling fan/ exhaust fan/ LED fittings as required.

26296

-

-

... More
VAV-08-GF-H 2082 625

1

-

-

... More
Supplying, installing, testing and commissioning of a rack mounted central control unit with integrated PC, inbuilt USB recording capability, control software package that can be controlled using the front panel display using control keys or can be accessed by connecting any VGA monitor, keyboard and mouse that shall allow fault monitoring and error diagnostics and full control over all delegate units and the audio and conference parameters including equalization, feedback suppression, microphone limiting, and conference modes and digital processor which shall supply 52.8 vDC power and control data through a network bus for controlling up to 40 discussion units. An Ethernet port shall be provided for network connection and control through third party digital control systems. The remote delegate discussion units connected to the central control unit shall be hot-swappable during a conference. Audio frequency response shall be 100Hz to 14kHz and Input voltage range shall be -18dBu to +18dBu (XLR In). Maximum output level shall be +10dBV with a signal-to-noise ratio of greater than 80dB A-weighted at +18dBV. Total harmonic distortion shall be less than 0.01% A-weighted at +6dBV In and Out. Power consumption shall be 245W as per directed by Engineer in Charge.

1

-

-

... More
b) 80 mm dia - MS `C' Heavy class pipe. (Welded/Flanged Joints)

2047.6

-

-

... More
Extra for Labour Charges for lowering down in foundation Plain Cement Concrete M-10 with nominal mix of (1:3:6)

12544

-

-

... More
Outgoing

-

-

-

... More
4 sets of R, Y, B phase indicating (LED type) lamps

-

-

-

... More
VAV-02-GF-E 984 295

1

-

-

... More
Duct Humidity & Temperature Transmitter

64

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
VAV-02-GF-H 2165 650

1

-

-

... More
Under Voltage & Over Voltage protection with protection release.

-

-

-

... More
NORMAL EXHAUST FAN: Supply, installation, testing and commissioning of tube axial fan with adjustable pitched aluminium alloy impeller, TEFC squirrel cage induction IE2 motor with class 'F' insulation motor,930 RPM direct drive arrangement, GSS/MS sheet metal casing, and other accessories as required and as per specification of following capacities as per Schedule of Equipment. As Direction of E/C

-

-

-

... More
(c) ON/OFF push button with control fuses – 1 Set

-

-

-

... More
Trip Command Relay

-

-

-

... More
1. Load / Speed:20 Persons (1360Kgs.) / minimum 1.00 Mtr. Per Second. 2. Total Travel distance: (4.5+4.5+4.5) 13.5metre . 3.Machine Room:-YES. 4.Floor Display Char: LGF,GF,1ST & 2ND. 5.Number of Landing Entrances: Four 6.Size of Lift Well: 2550X 2450 (MM Wide X MM Depth)

32

-

-

... More
Supply,installation,testing and commissioning of wafer type butterfly valve of rating PN16 complete with insulation & all accessories and all other parameters as per the technical specifications given in the tender. Valves 150 and above dia shall be Gear operated. Seat shall be integral moulded with EPDM. disc shall be of SS304. As Direction of E/C

-

-

-

... More
Incoming

-

-

-

... More
Supply, Installation, Testing & Commissioning of 55" 4K LED display,  Panel Technology: IPS, Resolution:3,840 x 2,160 (ULTRA HD),brightness:500nits, Contrast ratio-1000:1, Dynamic Contrast ratio-1000000:1,Connectivity: HDMI,DVID,DP,RS232C,RJ45,IR, Audio, RS232C, USB 3.0, SD Card slot, Built in WiFi, Quad Core Processor/SOC , Dust/Humidity Protection-Conformal coating, Typical power consumption-120w or less, Features-Temperature Sensor, Auto Brightness Sensor, At least 15x15Tile Mode, ISM Method, USB Cloning, Contents Scheduling, Sync mode, PM mode, Fail Over, Wake on LAN,  Certification- UL / cUL / CB / TUV / KC, FCC / CE / KCC as per directed by Engineer in Charge.

1

-

-

... More
MOTORISED BUTTERFLY VALVE (i) 200 mm dia

8

-

-

... More
Supply and installation (on cable trays) of the following sizes of 1.1 KV grade PVC insulated copper conductor armoured stranded Power cable complete as required and as per specifications s per directed by Engineeer in Charge.

-

-

-

... More
(xi) 0-40 A Ammeter with ammeter selector switch & 40/5 CT's - 07 Sets.

-

-

-

... More
(b) ON / OFF / TRIP Indicating Lights with control fuses – 1 Set

-

-

-

... More
(iv) 25 A TP MPCB - 02 No.

-

-

-

... More
(d) R, Y, B phase indicating LED light with 2A MCB - 1 set

-

-

-

... More
DG/Bus monitoring PT's - 1 Set

-

-

-

... More
(iv) 0-16 A Ammeter with Ammeter selector switch & 16/5 C.T.s - 13 Sets

-

-

-

... More
UMDB-SF UPS MAIN DISTRIBUTION BOARD) ( SECOND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 1 as per direction of Engineer-in-charge

2

-

-

... More
Incoming

-

-

-

... More
35mm thick Metal Door SIZE 600MM(W)X1350MM(H) Single Shutter,frame Including Hardware.(3nos. 100mmx75mmx3mm MS Butt Hinge, 2nos.250mm Long D-Type MS Handle Fabricated MS 20mm dia ROD, 2 no.250mm Aldrop Finished painted as per approved colour) complete in all respect.

16

-

-

... More
8 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
3.5 C x185 sq mm A2XFY cable

240

-

-

... More
Note: All metering current transformers shall be Class 0.5, 05 VA, cast resin type.

-

-

-

... More
Pendent type (68 deg.C) sprinkler

11670

-

-

... More
Lettering Size 600 mm. Height in english & hindi

220

-

-

... More
Celing Finish :- Decoration as per Drawing & Design (Material paid in separate item )

-

-

-

... More
Providing and fixing Cast Carbon Steel / forged brass CS Ball valve (Hyd. Test pressure body 30 kg/cm2 & seat 21 kg/cm2) of the following size: (Cost shall be inclusive of providing necessary union / flange connection).as per direction of Engineer in Charge.

-

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire [Power Point Circuiting]

235794

-

-

... More
Fast discharge resistors to be used for fast discharging of capacitor.

-

-

-

... More
(ii) 38600

1

-

-

... More
Outgoing

-

-

-

... More
(a) 20 mm nominal bore.

0.56

-

-

... More
Providing, fixing, testing & commissioning of SS spring loaded air relief valve for pressure of 16 kg/sqm of approved quality with SS isolation valve, tapers, G.I. pipes and specials etc. including making necessary screwed/ flanged joints by providing all jointing materials including painting and testing the joints to hydraulic pressures specified for pipes all complete as per drawings and as directed by the Engineer-in-Charge.

-

-

-

... More
All ACB'S shall have spare wired contacts for ON,OFF,Trip,rackin,rackout spring charge status for SCADA / BMS communication along with LCD display.

-

-

-

... More
ACSDB-02 (F) Supply, installation, testing and commissioning of following distribution boards totally enclosed compartmentalized, cubicle floor mounted, indoor type IP:42, factory fabricated with 2 mm thick sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply suitable for 25 KA as per specifications and drawings. All Air Circuit Breakers shall be provided with Micro processor based Earth fault, short circuit and over current releases. Moulded case circuit Breakers shall be microprocessor based electronic trip. Fault level for all ACB/MCCB and bus bar shall be 25 KA, all the motor feeder shall be type-2 coordinated. ICU shall be equal to ICS=100% . As Direction of E/C

2

-

-

... More
(ii) 30315 CMH at SP at 15 mm WG ( Minimum Efficiency - 60%)

2

-

-

... More
1 no. 630A 4P MCCB, 35 KA microprocessor controlled with overload, short circuit and earth fault protections.

-

-

-

... More
1 Set of 100/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Providing and fixing 15 mm dia C.P. brass Stop cock (Concealed) of standard design and of approved make conforming to IS:8931. for shower.

76

-

-

... More
Kickers (320 mm wide, 5 mm thick)

166

-

-

... More
LT CABLES Supply, installation, testing & commissioning and laying on Cable Tray / Surface with Clamps, heavy duty armoured XLPE insulated and sheathed, as per ISI mark, 1100 volts grade aluminium stranded conductor cable of size as below all as specified

-

-

-

... More
UMDB-FF UPS MAIN DISTRIBUTION BOARD) ( FIRST FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 2 as per direction of Engineer-in-charge

2

-

-

... More
7 Set of 25/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Extra for Labour charges Over 3metre height for AAC Block work in C.M. ( 1 : 4) in superstructure for each floor/over Roof

4410

-

-

... More
Providing, fixing, Chlorinated polyvinyl chloride (CPVC) pipes SDR11 , having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1m spacing . This includes jointing of pipes and fittings with one step CPVC solvent cement and cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge.Concealed work including cutting chases and making good the wall etc.

-

-

-

... More
PUMP PANEL - 2 (AT MAIN BUILDING) as per directed by Engineeer in Charge.

2

-

-

... More
Auxiliary contacts required for necessary interlocking of breakers.

-

-

-

... More
Outgoing

-

-

-

... More
2x37 kVAr LT power capacitor banks with 2 No. 30 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
CONFERENCE ROOM 208 Seater : Supplying, installing, testing and commissioning of wireless digital Handheld Microphone with 18 or more channel, RF output 100mW or more, super cardiod pickup pattern, Frequency range : 1880 to 1930 MHz, Connectivity : RJ-45, Battery backup : 17 or more hr etc and complete as required with 1 nos 2 port charger of same OEM as microphone as per directed by Engineer in Charge.

4

-

-

... More
DDC- 49

2

-

-

... More
(b) Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m.

148

-

-

... More
Supplying, fitting and fixing C.P. brass Soap dish container medium quality with screw and hinges etc.

392

-

-

... More
Horizontal side wall sprinkler

240

-

-

... More
Supplying and laying of Water Proof PVC insulated Copper Cable of 3C x 2.5 Sq.mm. size suitable for the Submersible Motor as per direction of Engineer in Charge..

2850

-

-

... More
110 mm inlet and 75 mm outlet

106

-

-

... More
4 C x 10 sq mm A2XFY cable (25mm)

928

-

-

... More
32mm nominal outer dia. Pipes

512

-

-

... More
Water Flow Rate- 2958 LPM, Head - 15 m ( For East Block) /Water Flow Rate- 2730 LPM, Head - 15 m ( For West Block) Lot, RCC foundation for the pump.

-

-

-

... More
Control Fuse - 1 Set

-

-

-

... More
Stairs, (excluding landings) except spiral-staircases

12022

-

-

... More
Fan assembly shall be statically and dynamically balanced to G 2.5 grade as per ISO 1940.

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
FOR WEST BLOCK Max. Setting Min. Setting

-

-

-

... More
Clamp & Anchor:- [Note:-This items of work should be executed by approved applicator with sufficient credential] Supplying ,drilling & fixing Stainless Steel Clamps 80-120mm, 304 SS with Stainless Steel Chemical Anchors for Dry stone Cladding work applicable on concrete & AAC block surface complete in all respect as per manufacturer methodology & the clamp body shall be of minimum 5mm thickness and shall be able to carry a dead load of 79.5 kgs at minimum offset as per direction of the Engineer-in-charge. (Rate is inclusive of 3rd party pull out Test at Site. )

154558

-

-

... More
Supply, Installing, testing and commissioning of  licenses of 48 port non POE 8 x 10GE Network Module(Already bundled with Controller hardware) as per directed by Engineer in Charge

-

-

-

... More
Loss of excitation relay

-

-

-

... More
VAV-04-GF-D 2624 787

1

-

-

... More
Bus Bar

-

-

-

... More
VAV-05-1F-C 4045 1214

1

-

-

... More
Bend 87.50.

-

-

-

... More
Providing and fixing weather proof lockable cabinet of size not less than 0.75 x 0.45 x 0.25 mtr made out of MS sheet of 20 gauge thickness having central opening and 4 mm thick glazed glass doors (Two nos.) suitably marked on the outside with the letters "FIRE HOSE" including necessary locking arrangement and shall be painted with one coat of primer and two coats of synthetic enamel paint of approved shade. The cabinet shall be suitable to accommodate 2 nos. 15 mtr long Hose pipe & 1 No. branch pipe nozzle. It shall be mounted on Pilon pipe and one plate is welded on the pipe top to fix with hose box. as per direction of Engineer in Charge. (Cost shall be inclusive of providing break glass box containing key for the cabinet along with hammer).

187

-

-

... More
Close timbering in trenches including strutting shoring and packing cavities (whenever required) for each additional depth 1.5m complete as per specification and direction of E/I (Measurement to be taken of the face area timbered)

55360

-

-

... More
VAV-05-2F-E 2580 774

1

-

-

... More
(ii) 0-500 V Voltmeter with Voltmeter selector switch and control fuses - 1 Set

-

-

-

... More
3 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Providing & fixing indoor type hose lockable cabinet frames fabricated from 40 x 40 x 5 angle iron sections and 16 gauge MS sheet with full front glass door and locking arrangement, suitable to accommodate landing valves, 15 m long hoses, first-aid hose reel and branch pipe nozzle & fire mans’ axe. The cabinet frame shall be painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade, as required (Approx 2.1 m (high) x 0.9 m (wide) ). The item shall be complete of MS housing with front door. (Cost shall be inclusive of providing break glass box containing key for the cabinet along with hammer) .as per direction of Engineer in Charge.

73

-

-

... More
1) Casing- Shall be made of 0.63 mm galvanised pre - plasticized /power coated sheet on outside and 0.63 mm GI sheet inside with PUF foam of 36 kg/m³ density insulation in between sheets to make 25 mm thick panels.

-

-

-

... More
(i) 375 mm dia

464

-

-

... More
(i) 3000 A, 415V, 3ph, 4 wire Aluminium busbar

-

-

-

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire

14138

-

-

... More
SOFTWARE

-

-

-

... More
b. Wastage on materials and labour

-

-

-

... More
Incoming

-

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Providing and laying in position cement concrete excluding the cost of centering and shuttering - All work up to plinth level of specified grade 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) (Note:-Packing annular space between the outside of the housing pipes and the bore)

16

-

-

... More
2 no. 20A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Supply, Installing, testing and commissioning of  48 port non POE 8 x 10GE Network Module with 5 year warranty as per directed by Engineer in Charge

10

-

-

... More
32 mm nominal outer dia .Pipes.

8

-

-

... More
(v) 450 mm width X 62.5 mm depth X 2.0 mm thickness

180

-

-

... More
SPECIAL INCLUSIONS :Scrolling Type Direction & Position Indicators In Car & Landings Battery Operated Emergency Light And Alarm Bell Call Register Signal And Vf Door Operator False Ceiling In Car Infra Red Door Screen-2d Overload Warning Indicator Automatic Rescue Device Firemans Switch Vandal Proof S.S./Brass Finish For VIP Lift Button With S.S./Brass Finish for VIP Lift Cover 3 Way Intercom / Press And Speak Phone Full Car Operating Panel SS/Brass finish for VVIP Lift Handrails On 3 Sides Braille Buttons Floor Annunciator With Music Hall Arrival Lantern With Gong Next Landing Operation Safe Landing Operation Landing Push Button In Landing Door Frames Lift License to be arranged by the contractor with no extra cost. NOTE : AS PER IS 14665 STANDARD, BATTERY OPERATED AUTOMATIC RESCUE DEVICE (ARD) SHALL BE PROVIDED ON ALL LIFTS TO TAKE THE LIFTS TO THE NEAREST POSSIBLE LANDING IN CASE OF POWER FAILURE, LIFTS EQUIPPED WITH BACKUP GENERATOR WITH AMF (AUTOMATIC MAINS FAILURE) PANEL.

-

-

-

... More
Lot, RCC foundation for the pump.

-

-

-

... More
Breaker control switch - 1 Set

-

-

-

... More
Supplying, installation, testing & commissioning 50 Pair Raiser Cable as per specification as per directed by Engineer in Charge

44000

-

-

... More
(iv) 3680 20

1

-

-

... More
VAV-02-2F-A 3380 1014

1

-

-

... More
Supply & Fixing in position as per Drawing & Design Ornamental Teak Wood moulding Bead size as follows finished with painting/ lacoured/French Spirit polished complete in all respect as per direction of the Engineer In charge.

-

-

-

... More
160 mm dia

3356

-

-

... More
ACSDB 02 AHU ROOM : Supply, installation, testing and commissioning of following distribution boards totally enclosed compartmentalized, cubicle floor mounted, indoor type IP:42, factory fabricated with 2 mm thick sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply suitable for 25 KA as per specifications and drawings. All Air Circuit Breakers shall be provided with Micro processor based Earth fault, short circuit and over current releases. Moulded case circuit Breakers shall be microprocessor based electronic trip. Fault level for all ACB/MCCB and bus bar shall be 25 KA, all the motor feeder shall be type-2 coordinated. ICU shall be equal to ICS=100% . As Direction of E/C

2

-

-

... More
4 Strip aluminium bus bar of 200 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 35 KA fault - 1 set

-

-

-

... More
Carriage of Earth - lead Beyond 1km upto 2km

127366

-

-

... More
(i) 0-200 Ammeter with Ammeter selector switch and 200/5 C.T.s -1 Set

-

-

-

... More
a) Providing and fixing gun metal non- return valve Horizontal / Vertical type of approved quality as per specification and direction of Engineer-In-Charge.Horizontal non- return valve

-

-

-

... More
c) 5.5 KW - 04 No.

-

-

-

... More
Providing and fixing butterfly valves of PN 1.0 rating, wafer type, C.I. body I.S. 210 FG 220, disc: C.F.8/SS304, shaft AISI 410, seat ntegrally moulded Nitrile/EPDM of approved make, handle lever with on /off indication all complete as required complete as per direction of Engineer-in-charge.

-

-

-

... More
(i) 0-100 Ammeter with Ammeter selector switch and 100/5 C.T.s -1 Set

-

-

-

... More
1 Set of 1600 A 4P ACBs 65KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings.

-

-

-

... More
DDC- 3

2

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
Supply EMERGENCY LIGHT Signage with minimum 3 hrs. battery back up of approved make at any floor at any height,made of Aluminium frame with approved size of lettering, Colour, Base Colour & Image,necessary fixing arrangement complete in all respect as per direction of Engineer In Change. PEL LED E/M (S)

322

-

-

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe 40 mm dia

174

-

-

... More
1 set of Digital Ammeter with class-0.5 with 1 Nos. 3200/5A 15 VA CTs.

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Outside Temp. & RH Sensor - 1 No.

-

-

-

... More
(ix) 6.3 mm

185

-

-

... More
a) KW Motor -

-

-

-

... More
600 mm width x 50 mm depth x 2.0 mm thickness

4

-

-

... More
Providing and fixing Pre approved Granite stone slab 18 mm thick semi polished in risers of steps with single piece laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete with Single piece all lead & lift as specified and as directed by Engineer-in-charge.

1078

-

-

... More
2 C x 6 sq mm A2XFY cable

5200

-

-

... More
Stair Railing with glass:- Design , Supply , fabricate and installation of Railing System for Staircase comprising of Stainless Steel 304 Grade & Glass with patch fittings, having Baluster 110 x 60 mm Base Plate, up to 900mm high with provision of adjustable head for fixing S. S. Hollow Bar of 50mm dia & 4 Holes for patch fittings holding 2 Nos. Double toughened Glass (size 1000mmx550mmx10mm) Holders made of SS to be provided in each Baluster with Center Distance of 440 mm vertically. The Hand Rail to be installed to the Baluster using SS Screws at 50mm Center distance. The average distance between 2 balusters to be 1000mm. Glass to be fitted inclined complete in all respect as per direction of the Engineer in charge. (SHOP DRAWING TO BE PROVIDED & DULY APPROVED BEFORE EXECUTION OF THE WORK)

1692

-

-

... More
Set Selector Relay

-

-

-

... More
IP Phones as per directed by Engineer in Charge

94

-

-

... More
(i) 75 mm diameter.

8

-

-

... More
Incoming

-

-

-

... More
Auto-manual / test selector / switch - 2 Sets

-

-

-

... More
(xxxiv) AH-3F-03* 19 17400 4

1

-

-

... More
1 Set "ON /OFF" push button with 2A, 3P MCB, 10KA

-

-

-

54797.3

-

-

... More
Providing and fixing ball bearing for rolling shutters.

44

-

-

... More
24 Core x 0.75 Sq.mm Cable

12

-

-

... More
VAV-05-GF-C 1055 317

1

-

-

... More
11 KV HT PANEL ( As per IEC 62271-1, 100 & 200) (AT SUBSTATION) as per directed by Engineeer in Charge.

2

-

-

... More
LIFT LOBBY PRESSURIZATION (i) 12750 CMH at SP at 20 mm WG

8

-

-

... More
Outgoing

-

-

-

... More
(xiii) 0-16 A Ammeter with ammeter selector switch & 16/5 CT's - 06 Sets.

-

-

-

... More
c. Loading, transporting, unloading, handling/double handling, hoisting to all levels, setting, fitting and fixing in position, protecting, disposal of debris and all other labour necessary in and for the full and entire execution and for the job in accordance with the contract documents, good practice and recognized principles.

-

-

-

... More
Condenser Water Outlet Temperature: 36.4 deg. C

-

-

-

... More
1 Set of 100/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Lot, Anti-vibration/noise mountings including masonry foundations as per manufacturer recommendation etc.as required

-

-

-

... More
(xi) VFDs in suitable enclosure shall be installed near the equipments for motors of following ratings:-

-

-

-

... More
VAV-04-1F-G 2295 689

1

-

-

... More
Incoming

-

-

-

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood

10.08

-

-

... More
Check valve Condenser Line:-Supply,installation,testing and commissioning of Dual plate Non return valve of cast iron 210 Gr., ASTM A-217 Gr. Plates - SS410, Hinge/ Stop Pin SS- 316 with EPDM seal, PN 16 rating complete with all other parameters as per the technical specifications given in the tender. As Direction of E/C (i) 250 mm dia

6

-

-

... More
Construction brick masonry chamber for underground C.I Inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand), finished smooth etc. complete as per standard design. Inside dimensions 500 x 700 mm and 45 cm deep for pipe line with one or two inlets:

-

-

-

... More
ii) 200 mm nominal size dia having minimum wall thickness 5.40 mm

840

-

-

... More
(b) Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.

46

-

-

... More
Operator Console as per directed by Engineer in Charge

2

-

-

... More
(b) ON / OFF / TRIP Indicating Lights with control fuses – 1 Set

-

-

-

... More
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width

40362

-

-

... More
i). Night service/ Day service,

-

-

-

... More
Supplying, installing, testing and commissioning of HDMI, DP Cable connectors ( Make: Standard) as per directed by Engineer in Charge.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 06 Port LC Duplex 1U 19" Rack Mount LIU with Panel, Splice tray and necessary accessories and fully Loaded, as per the specifications as directed by Engineer in Charge.

20

-

-

... More
Supply, Installation, Testing & Commissioning of Rack Mounted 8port Gigabit L2 managed switch with 4 SEP uplink port as directed by Engineer in Charge

10

-

-

... More
RELAYS W/O COMMUNICATION

-

-

-

... More
4Sets of D.O.L. Starters suitable for above motors complete with metering, single phasing preventor, over load relay etc.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Client Workstation. Dual Core i5 2.67 GHZ Processor, 16GB RAM, 2 TB HDD, GPU that supports OpenGL 3.0, 100/1000 Ethernet Network Interface Card, Sound Card, Original Windows 7 Pro 64 bit with .NET 4.6.1 or higher, OpenGL 3.0, Direct3D 9. The Client Workstation should have adequate number of GPU Card for 2 DVI and 2 HDMI output for connecting 03 Nos. 55" LED Monitor each as directed by Engineer in Charge.

4

-

-

... More
(ii) Star Delta / DOL starter with ON/OFF indicating light, ON/OFF push buttons, control fuses, timers, contractors, overload relay with built-in single phase preventor, control fuses, wiring, interconnections suitable for following rating motor.

-

-

-

... More
VAV-08-2F-H 2260 678

1

-

-

... More
Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc.

75454

-

-

... More
3.5 C x 95 sq mm A2XFY cable

76

-

-

... More
Check Synchronizing Relay II OvAC,5OHz - 1 No.

-

-

-

... More
• Frequency range: 50 Hz

-

-

-

... More
e. All requirements of Specifications, whether such requirements are mentioned in the item or not. The Specifications and Drawings where available, are to be read as complimentary to and part of the Schedule of Quantities and any work called for in one shall be taken as required for all.

-

-

-

... More
Supply, Installation, Testing and Commissioning of DDC controller with 32 bit processor, 512KB Flash Memory and 512KB RAM with SD Card Slot for Memory Expansion and real time clock with and internal schedules to maximise energy savings of the buildings. Controller should communicate on the international ISO 16484-5 BACnet® standard, it should be freely programmable controller with 16 PID Controllers and LEDs for both I/O status indication and diagnostic for RS-485, Ethernet and communication bus. Controller should have HOA (Hand - Off - Auto) Override Switches for DO/AO. Controller must have two on-board RS-485 channels for BACnet MS/TP or Modbus communication complete with DDC Housing Panel. The DDC Panel shall be MS Powder Coated, IP 44 Rating for indoor; and IP 54 for outdoor. The DDC Panel shall be with proper mounting accessories for DDCs such as DIN Rails, Elemex Terminals for Cable Terminations, Dressings for internal cabling, ferruling, tagging etc. The DDC Panels shall have SMPS Power Supply to meet the power requirement of the DDCs, Instrumentation and other connected equipment. Shall be Complete with pilot relays, fuses, overload protection relays, auxiliary power output socket etc. as required to complete the installation and intended usage as per directed by Engineer In Charge .

-

-

-

... More
Supply, installation, testing & commissioning of Intelligent addressable micro processor based 2 wire fault tolerant loop, single loop with Peer to Peer network communication system with additional 20% Spare capacity in each loop fire alarm/detection and integrated voice evacuation control panel of same make having 8 simultaneous multiplexed audio channels with minimum 640 Character LCD Display with sufficient panel enclosure and cabinet size to accomodate Integrated voice evacuation unit for automated messaging. The panel shall have control and display switches for 24 speaker zones with one-way and two-way emergency audio communications facility. The system should have automatic mapping feature .Panel should operate with 240volts AC power supply, automatic battery charger of suitable capacity, 24volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 min during an emergency conditions as required. The panel should have port to connect online printer. System is capabale of generate alarm condition if central processing unit fails. The network shall support min 64 panels / nodes per network. (UL 9th or latest Edition and FM approved). Mounting accessories of main fire panel and electrical connectivity from nearest DB and civil works shall be in the scope of bidder (Main FIRE ALARM PANEL WITH INTEGRATED EVAC CONSOLE) as per directed by Engineer in Charge.

2

-

-

... More
5 Nos. 125 Amps TP MCCB,50 KA, Thermomagnetic Protection controlled.

-

-

-

... More
Ceiling Mounted Batten type Led Luminaire with 2x18w(±10%) LED Tube light, Life of fixture 50000hrs@L70 Lumen maintenance, Color Temp. =5700, CRI 80, PF 0.95, 2.5KV Surge protection, an operating Voltage Range of 180 - 240 V, Standard Deviation Colour Matching (SDCM) 4, Minimum system Lumens 3600Lumens, similar to Bajaj Cat. no. BLRB 218 +2Nos LED Tube Light or equiv.Sample luminaire shall be got approved by Engineer-in- charge / consultant.

48

-

-

... More
Flow switch

-

-

-

... More
VAV-02-3F-B 3060 918

1

-

-

... More
VAV-06-3F-F 651 195

1

-

-

... More
Providing and laying Screed concrete 50 mm (av.) thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).Extra for providing and mixing water proofing material in cement concrete per 50 kg work in doses by weight of cement as per manufacturer’s specification as directed by the Engineer-in-charge complete in all respect.

8394

-

-

... More
Flow rate 3690 LPM/Head 30 m ( East Block) /Flow rate 3420 LPM/Head 30 m ( West Block) Pump Minimum efficiency shall be 75%.

-

-

-

... More
DDC- 24

2

-

-

... More
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady] the frame.

446

-

-

... More
(iv) 50 mm dia

18

-

-

... More
(i) 100 A, 415V, 3ph, 4 wire Aluminium busbar

-

-

-

... More
(f) 65 mm nominal bore.

20

-

-

... More
VIDEO STORAGE AND MANAGEMENT SOFTWARE / HARDWARE Supply, Installation, Testing & Commissioning of Video Management / Recording servers for VMS to be considered for minimum 300 cameras. It shall have Intel® Xeon® E3-1275 v3 or better with 32 GB DDR3 ECC RAM or better. It should run on Microsoft® Windows® Server 2012 or latest. edition. It should have SSD storage for operating system. This shall include the required hardware cost and the software cost for the same as per the system requirement . Shall support Dynamic Host Communication Protocol ( DHCP ) and Network Time Syncronisation Protocol ( NTP ) functionality . It shall support hot standby N+N active failover without any manual intervention. all complete including 3yearsX24DaysX7 Hours of Technical Support and Updates, Single Server License as directed by Engineer in Charge.

2

-

-

... More
(The Contractor shall give a 10-year service guarantee in writing supplemented by a separate and unilateral guarantee from the pre approved specialised agency for the job to keep the building free of termites for the specified period at no extra cost to the owner.) Anti termite treatment with chemical (Imidaclprid 30.5 SC) shall be used at 0.075% concentration (2.1 ml of chemical mixed in 1 ltr of water OR in other words mixing ratio of chemical to water is 1:475) with water by weight at the rate of 5 Liters per sq. m.of the surface before sand bed is laid. (For top surface of the consolidated earth at plinth holes upto 50 mm. to 75 mm. deep at 150 mm. center to center both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil and also to the Foundation bed ,Basement excavation, back filling Vertical side, Plinth & extended portion ,Soil Surrounding Pipes, Wastes and Conduits, special care at below construction joints, beneath Junction of the Wall and the Floor etc. with the chemical as above) .The work should be carried out as per specification described in para 6.4 of code IS-6313 (part-2&3) 2013 by a specilised agency duly preapproved. ( Mode of measurement will be per Sqm of Plinth area of the Building as per Drawing.)

47896

-

-

... More
40mm dia

7

-

-

... More
VAV-02-2F-H 2975 893

1

-

-

... More
Extra for shuttering in circular work (20% of respective centering and above shuttering items )

960

-

-

... More
300 mm centers. Then suspend Main channels(MC 45) having thickness 0.9 mm, length 3600 mm, equal flanges of 15 mm and web 45 mm from the soffit at every 1200 mm centers with Suspender angle(SA 25) having thickness 0.45 mm, unequal flanges of 25 & 10 mm. GI Cross channel(CC 25) having thickness 0.45 mm, length 3600 mm, knurled web 35 mm, depth of 25 mm and equal flanges 9.5 mm is fastened to the Main channel in the direction perpendicular to the main Channel at every 450 mm centers. Apply synthetic poly fiber PF 5 x 10 acoustic wool of 50 kg density to be kept on the top of the wooden ceiling by laying on the frame work as per direction of Engineer in Charge.

735

-

-

... More
DDC- 40

2

-

-

... More
25 MMX 40MM

1000

-

-

... More
Supply, installation, fixing, testing and commissioning of the Graphical workstation shall have following components like Processor Intel(R) Core(TM) i5, RAM - 16 GB , Monitor - 32" LED, Hard Drive - 2TB 7200 rpm SATA 6Gb/s Hard Drive, Video Card - NVIDIA(R) GeForce(R) 705 2GB GDDR3, Optical Drive - DVDRW Optical drive, Ports – Rear - (4) USB 2.0, Network Port, Operating System- Windows 10 with all related accesseries to connect with Fire Panel. This equipment should be placed at Fire Control Room. The interconnection between main fire panel to workstation, complete with all accessories shall be in the scope of bidder as per directed by Engineer in Charge.

2

-

-

... More
BOOM BARRIER Supply, Installation, Testing & Commissioning of Electric motor Boom Barrier of • Power supply: 230+/- 10% VAC, 50 Hz • Finish: - Control Unit-Power coated in a suitable colour (to be approved by the Client / Architect). - Boom- Powder coated white then applied with bright red colour reflecting tape strips. • Boom specifications: - Length- 1000mm to 6000mm (Size as per Layout) - Straight, extruded aluminium alloy • Protection: IP 44 • Housing metal: All housing and internal parts will be rust and corrosion free metal or alloys of high strength with suitable epoxy coating as applicable. • Opening and closing time: 1.5 to 6 second • Duty cycle: 100% • Integration: Shall function in integration with proximity reader based access control system • Mean Time Between Failure (MTBF) : 2 million operations Sample shall be got approved by E.I.C. / consultant.

4

-

-

... More
SITC of Cabling for instrument, controls, valves to DDCs and communication cabling from DDC to central equipment complete with earthing, supports etc complete. Laid on Surface / On Cable Trays. All Cables shall be ferruled and tagged, and shall use lugs for termination at both ends. All cables shall be properly glanded at Panel and the third party field panels to ensure proper installation as per directed by Engineer in Charge.

-

-

-

... More
3 Sets of 200 A 4P MCCBs 50 KA miroroprocessor based controlled with overload, short circuit and earth fault protections.

-

-

-

... More
14 Sets ON / OFF / TRIP indicating lights with SP MCB’s.

-

-

-

... More
Supplying, installation, testing & commissioning of 2 core 0.5 sq mm stranded bare copper, cellular polyethylene insulated, overall shielded PVC jacketed DMX512 digital cable,

12000

-

-

... More
(ix) 1900 450 900

1

-

-

... More
Wall painting with premium acrylic emulsion paint of interior grade,having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats

4601

-

-

... More
(d) R, Y, B phase indicating LED light with 2A MCB - 1 set

-

-

-

... More
VAV-01-LGF-F/04-3F-C 4200 1260

2

-

-

... More
Supply, installation, testing and commissioning of 2C x 1.5 sqmm control cum transmission wiring/power/control cabling with PVC insulated, PVC sheathed, multicore copper conductor control cable in suitable conduits between indoor and outdoor units and its remote controllers. As Direction of E/C

1200

-

-

... More
Supplying, fitting and fixing Electrical Control Panel Board suitable for outdoor installation of adequate size made out of 2mm thick CRCA M.S. sheet and M.S. flat painted with suitable enamel paint fitted with required electrical accessories of approved make suitable for submersible pump - motor set, described above, including Automatic Star Delta Starter, Main Switch, Single Phase Preventer, Overload Protection Device, Water Level Controller with two probes, one for low level audible warning and one for very low level for tripping of the motor with all required electrical works, Amp. Meter, Volt Meter with Selector Switch, Indicator Lamp, on & off push button, Danger Board etc. as required. (2W+1S) 2 nos of pump.) as per direction of Engineer in Charge

6

-

-

... More
Painting G.I. pipes and fittings with two coats of anti-corrosive bit mastic paint of approved quality.

-

-

-

... More
110mm OD Class 6(PN)

1280

-

-

... More
Outgoing

-

-

-

... More
(iv) 6 A TP MPCB - 05 No.

-

-

-

... More
Providing and laying D.I. specials of class K- 12 suitable for push-on jointing as per IS : 9523.(a) Up to 600 mm dia.

214

-

-

... More
(ii) 0-500 V Voltmeter with Voltmeter selector switch and control fuses - 1 Set

-

-

-

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump : capacity 180 lpm at 70 m head ) (a) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. (c) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads.

4

-

-

... More
(h) 150 mm nominal bore.

20

-

-

... More
Supplying, installation, testing & commissioning of 75 watt RGB wallwasher Light, Protection : IP65 Class 1, Input Voltage : 220V AC, Operating Voltage : 24V DC, Power Consumption : 75 watt, Beam Angle : 8 deg, Control Mode : DMX, Housing : Aluminium Alloy, Operating Temp : -20 to 50 deg, 3 pin XLR input/output,

272

-

-

... More
(xii) 24150

1

-

-

... More
(v) Star Delta / DOL starter with ON/OFF indicating light, ON/OFF push buttons, control fuses, timers, contractors, overload relay with built-in single phase preventor, control fuses, wiring, interconnections suitable for following rating motor.

-

-

-

... More
Server Room/Raised Flooring :-Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the Architectural drawings, as specified and as directed by Engineer-in-charge consisting of Panel Lifter With Wall Mount for Server Room/Raised Flooring

30

-

-

... More
2 run of cable

1812

-

-

... More
Supplying, installing, testing and commissioning of a digital desktop chairman microphone unit with chairman control buttons, 15” or longer gooseneck microphone with a super-cardioid capsule, 3.5mm headphone output jack, RJ45 jacks and twin loudspeakers which will connect to the central control unit via network using industry standard Category 5 (24 AWG) cabling. Optional strain reliefs can be provided for fixed installations. The audio signal path shall include a digital signal processor limiter. Operating voltage shall be 35vDC to 52.8vDC. Maximum power consumption shall be 3.8W. Total harmonic distortion shall be a maximum of 0.03% at 50mW/16 Ohms. as per directed by Engineer in Charge

1

-

-

... More
3 No. adjustable Frequency drives.

-

-

-

... More
Jali Work:- Design , Providing, Fabricate & fixing in position designer Jalli work of approved design with necessary supported Teak wooden Vertical & Horizental member at specified area complete in all respect and as per direction of Engineer in Charge . Framework & Jaliwork paid in separate item:-(Shop drawing should be approved by the Architect before execution of the work)

-

-

-

... More
Supplying, fitting and fixing Puddle collar in RCC walls or floors etc. assembly/sleeves consisting of MS pipes(Heavy type) conforming to IS : 1239 and IS : 3589 having required shell thickness, both ends flanged drilled to IS specification and one end matching blank flange(welded to pipe) with nuts, bolts, washers etc.and MS collar of minimum 6 mm thickness of specified size welded all round the pipe complete including three coats of bituminous paint on concealed portion and a coat of zinc oxide primer and two coats of synthetic enamel paint of approved shade on the exposed portion of the puddle collars as per direction of Engineer-in-charge. For 100mm to 250mm Dia Pipe.

497.97

-

-

... More
(ix) 13700

1

-

-

... More
Providing 1.5mm thick cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I

17826

-

-

... More
VRV/VRF UNIT:-Supplying, erecting, testing and commissioning of Variable Refrigerant Flow/ Volume (VRF/V) System, suitable to give the inside design temperature at 45°C ambient temperature comprising of the following and complete as required & as per specifications: As Direction of E/C

-

-

-

... More
4 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
VAV-06-GF-E 1148 344

1

-

-

... More
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) 78, solar reflection 0.70 and initial emittance 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.

48756

-

-

... More
4 Strip aluminium bus bar of 500 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
VAV-06-1F-E/03-2F-E 2970 891

2

-

-

... More
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

47318

-

-

... More
Starting System

-

-

-

... More
VAV-03-LGF-F 5595 1679

1

-

-

... More
VAV-01/02/03-LGF-G 4050 1215

3

-

-

... More
(vii) 6 A TP MPCB - 04 No.

-

-

-

... More
Above 35 sq. mm. and up to 95 sq. mm.

1200

-

-

... More
(i) 100 mm width X 50 mm depth X 1.6 mm thickness

4000

-

-

... More
Supplying, installation, testing & commissioning of heavy grade 1" dia PVC Flexible pipe

6000

-

-

... More
Supply, Installation, Testing & Commissioning of HDMI, DP Cable connectors ( Make:Standard) as per directed by Engineer in Incharge.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 2x2 Full HD Video Wall considering 55” IPS, LED, FHD panel, Hard coating, Anti-glare surface treatment , Bezel Width: Less than 1 mm (L/T/R/B) even bezel , Brightness: 500 cd/m2 or higher, Dynamic CR: 500000:1, Built in system - 1.2Gzh Quad Core CPU, 550MHz GPU, 2.5GBDDR3 RAM & 8GB storage or higher, SRC, Typical Power Consumption 150W or less per panel, atleast 15x15 Tile Mode, Weight per panel not more than 26KG, USB Cloning as per directed by Engineer in Incharge.

1

-

-

... More
Carriage of Earth - lead upto 1km (for disposal of surplus excavated soil from foundation trenches/Earthwork in Filling in foundation trenches and plinth/for filling in foundation trenches and plinth surrounded Upto 1km including loading, unloading and stacking in regular shape all complete as per direction of Engineer in- charge).

170293

-

-

... More
Supply, Installation, Testing & Commissioning of Biometric Fingerprint Reader as per detailed Technical specifications with all accessories complete as required as directed by Engineer in Charge.

8

-

-

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 3 way - 150 mm dia M.S. Pipe

44

-

-

... More
900 mm dia. R.C.C. pipe.

484

-

-

... More
(b) ON / OFF / TRIP Indicating Lights with control fuses – 1 Set

-

-

-

... More
12 no. 63A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Condenser Water Inlet Temperature: 32.2 deg C

-

-

-

... More
VAV-05-3F-C 3725 1118

2

-

-

... More
d) 200 mm dia

4

-

-

... More
1 nos. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Note : The bidders shall include the cost of system integration, software programming, system testing, commissioning, training to departmental engineers, hands-on demonstrations of the operation of all system components and the entire system, documentation (the systems manufacturer's representatives shall provide a typewritten "sequence of operation" to the owner) etc. as per technicial specifications shall be included in the offer. The cost of system integration shall be included proportionally in the rates of items indicated in the bill of quantities. Power Supply - A source of electrical operating power (UPS, including the circuits and terminals connecting it to the dependent system components are in the scope of bidder as directed by Engineer in Charge.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Central Management Server with Intel® Xeon® E3-1275 v3 Processor, 32 GB DDR3 ECC, Microsoft® Windows® Server 2012 or latest, 2 TB HDD, Intel HD Graphics P4700 or better, VGA interface, with Gigabit Ethernet Card(1000Base-T), Keyboard, Mouse and 21" LED Display Monitor complete as required as directed by Engineer in Charge.

2

-

-

... More
Sump pumps (Non-clogging type) in Sewege Lifting Sump Supply, installation, testing and commissioning Submersible type non-clogging Pump motor set (2 nos. of Pumps located in each sump in in Lower ground floor Sewerage Sump) of required drive (Motor HP), having discharge capacity and pumping head as described below with all electrical accessories viz.main switch and starter, auto on/off system with float arm (with fixed or flexible arm), over load protection relay, power cable and control cable from main switch and starter with auto on-off with dry running protection to respective motors, earthling having required M.S. galvanized supporting stay/ clamp etc. complete operational as per direction of Engineer in Charge.

-

-

-

... More
VAV-07-2F-E 2795 839

1

-

-

... More
250 mm dia. R.C.C. pipe.

9342

-

-

... More
(vi) 10 A TP MPCB - 10 No.

-

-

-

... More
250 mm diameter S.W./PVC pipe

1619

-

-

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

4902

-

-

... More
2 Nos. 125 Amps TP MCCB,50 KA, Thermomagnetic Protection controlled.

-

-

-

... More
Supplying, installation, testing & commissioning of CAT6A Patch Cord (Rack End) as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

7680

-

-

... More
4 no. 32A 4P MCCB, 25 KA Thermomagnetic controlled.

-

-

-

... More
(vii) AHU FAN SECTION --- 20900 ---

1

-

-

... More
Supplying, installation, testing & commisioning of communication module for Keypad. DACMV2. Can store and recall up to 21 configurations using the DIP switch, streamlining the commissioning and installation process as per direction of Engineer-in-charge

334

-

-

... More
Supply, Installation, Testing, & Commisioning of Gas Based Hooter

48

-

-

... More
q) Internal/External call ring difference, transferring a call- internal/ external, call forwarding/ Divert- no answer

-

-

-

... More
1 Set of R, Y, B phase indicating light (LED type) with 2A , SP MCB, 10KA

-

-

-

... More
ACB Aux.Relay

-

-

-

... More
VAV-06-1F-G 5375 1613

1

-

-

... More
(ix) HRU-1F-06- 2350 CMH Ceiling Suspended

1

-

-

... More
Supply, installation, testing, balancing and commissioning of powder coated extruded aluminium 3 Slot Return Diffuser of given size in the drawings with guide vanes etc., as required and complete as per specifications.

57

-

-

... More
5 no. 63A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
All Breakers (ACBs) shall have LCD Display

-

-

-

... More
Bus Bar

-

-

-

... More
3 Phase

-

-

-

... More
VAV-05-1F-D 2555 767

1

-

-

... More
Providing and Fixing of Multi cell (4 to 6 wall) of angular walls in opaque and translucent louvers combination Polycarbonate Panels having minimum panel width 600mm & 12 to 14mm thick fixed over MS supporting structure (paid in separate item) with necessary metal ridge cap to be provided at ridge. Width & fixing of the Panels should be as per approved manufacturer specification. Panel sheet to pass a cyclonic test/pull out test from a recognised and National aecredited laboratory in accordence with building codes like IS 4040-1992/ISO 6892:1998/IS1608:2005 or relevant BIS equivalent with a grade ''Satisfied'' or higher. The UV coating should block more than 99% of the UVA and UVB through a clear panel tested in an independent recognised and National aecredited laboratory as per AS/NZS/1067:2003 BIS or equivalent and direction of the Engineer-in-charge.

952

-

-

... More
Safety stud anchor M16x145/25

4

-

-

... More
2 Sets of 630/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
4 Strip aluminium bus bar of 150 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
VAV-05-3F-B 4150 1245

1

-

-

... More
Supplying, fitting and fixing Electrical Control Panel Board suitable for outdoor installation of adequate size made out of 2mm thick CRCA M.S. sheet and M.S. flat painted with suitable enamel paint fitted with required electrical accessories of approved make suitable for submersible pump - motor set, described above, including Automatic Star Delta Starter, Main Switch, Single Phase Preventer, Overload Protection Device, Water Level Controller with two probes, one for low level audible warning and one for very low level for tripping of the motor with all required electrical works, Amp. Meter, Volt Meter with Selector Switch, Indicator Lamp, on & off push button, Danger Board etc. as required as per direction of Engineer-in-charge.

12

-

-

... More
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :

-

-

-

... More
Providing & fixing Pressure Switch the most commonly used fluid control components of Aluminum enclouser with storage temprature 40 to 180°F (-40 to 82°C) along with ambient temprature 0 to 160°F (-18 to 71°C),set point shifts less than 1% of range for a 50°F (28°C) ambient temperature change. Unit will operate down to -40°F (-40°C) but with reduced repeatability. Maximum media temperature 200°F (93°C), Shock Set point repeats after 50 G, 10 millisecond duration. Switch output One SPDT including seven electrical terminations; Refer to 'How to Order' and vibration set point repeats after 10 G, 5-500 CPS. Note:Pressure Switch the most commonly used fluid control components of Aluminum enclouser with storage temprature etc. all complete work should be executed by specialized agency. The agency/contractor shall submit of shop drawings for Pressure Switch details of construction etc. for approval and according to the approved shop drawing a sample of each of system submitted for preliminary inspection for sample approval. After that the sample should be fixed at site to ascertain its performance. Large scale manufacturing should be taken up only after rectification of defects in sample as directed to the full satisfaction of the department / PMC and after obtaining formal approval of the same. as per direction of Engineer in Charge.

16

-

-

... More
Lot, thermal insulation on the pump with same material & thickness as the connected pipe

-

-

-

... More
Control Cables between DG & DG Incomer panel

-

-

-

... More
100 mm nominal inner dia .Pipes.

20

-

-

... More
Providing and fixing in position 100 mm diameter mosquito proof coupling of approved municipal design as per directed by Engineer in Charge.

32

-

-

... More
Supply, Installation, Testing and Commissioning of LED 4ft Batten with a nominal system lumen output of 3500(±10%) lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 5700k or 6500K, CRI80 and Standard Deviation Colour Matching (SDCM) =3 to =5. The luminaire shall meet IP20 rating with THD 10% and PF 0.95. The Batten should be flicker free(Ripple5%),with high cut-off Voltage at 320V and auto restart. It should have a surge protection of 2kV - 4kV. The luminaire housing should made of metal body with a PC UV shielding diffuser. The total power consumption should be with in 30W to 36W (including driver). Similar to Philips Cat. ENDURALED BATTEN "BN308C LED40S-6500 L120 PSU WH" or eqiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification Required: LM 79 & LM 80 . Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement. as per direction of Engineer-in-charge.

4666

-

-

... More
Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. For 510 x 19 mm.

8687

-

-

... More
3 run of cable

3280

-

-

... More
Outgoing

-

-

-

... More
Lot, RCC foundation for the pump

-

-

-

... More
a) KW Motor

-

-

-

... More
65 mm dia

64

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia

4980

-

-

... More
4 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Supply, Installation, Testing and Commissioning of Recess LED 595 X 595mm fitting with Smart Pyramid Optics, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) =130lumens/watt, Life of fixture 50000hrs@L70 Lumen maintenance, CCT 5700k or 6500k, CRI 80, PF 0.95, an operating Voltage Range of 220V- 240V, Standard Deviation Colour Matching (SDCM) =3 to =5. Glare free with UGR16. The total Power Consumption should be within 30W to 36W (including DALI driver) Minimum system Lumens 4000. Philips Model RC600B LED40S865 PSD W60L60 /6500K or equiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification Required: LM 79 & LM 80 . Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

370

-

-

... More
(i) 300 A, 415V, 3ph, 4 wire Aluminium busbar

-

-

-

... More
BALANCING VALVE CONDENSER LINE Supply,installation,testing and commissioning of balancing valve of rating PN16 with pressure test cocks only in SS -410 Stem, EN-3 Disc and EPDM sealing disc, complete with all accessories and all other parameters as per the technical specifications given in the tender. As Direction of E/C

-

-

-

... More
Providing & fixing Horizontal Venetian Blind of Skipper or approved make and pattern over Window including fittings & fixtureas as per Drawing & Design complete in all respect as per direction of the Engineer In charge.

7010

-

-

... More
3 no. 40A 4P MCCB,Thermomagnetic controlled.

-

-

-

... More
(f) 65 mm nominal bore.

26.18

-

-

... More
Bus Bar

-

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the Same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

310198

-

-

... More
Auxiliary contacts required for necessary interlocking of breakers.

-

-

-

... More
(iv) 250 mm dia

503

-

-

... More
Supply installation testing and commissioning of BUIDING OPERATING SYSTEM : FIELD SENSORS / EQUIPMENT, Co-ordination with building services, panels etc. to work entire system upto client satisfaction and as per directed by Engineer in Charge.

-

-

-

... More
(i) 250mm dia

2

-

-

... More
Providing & fixing Sash /Dead Lock Left & Right operation suitable for Wooden Flush door including cylinder, Locking hole cover for one side, inside locking knob with Floor wise Master key arrangement complete in all respect as per direction of Engineer in Charge. Material SS304 & SS finish

1145

-

-

... More
(e) 40 mm nominal bore.

996

-

-

... More
1) Louver with bird screen shall be in Architectural Scope.

-

-

-

... More
VAV-05-2F-B 3500 1050

1

-

-

... More
Outgoing

-

-

-

... More
Bus Bar

-

-

-

... More
Immersion type Temperature Sensors with S.S.mounting accessories of PTC 1000/Eq. of required range to measure water temperature in pipe line - 10 No.

-

-

-

... More
Providing PCC M-75 with nominal mix of (1:4:8) in foundation with approved quality of stone metal grade-III (50mm to 25 mm size) clean coarse sand of F.M 2.5 to 3 including screenings, shuttering, mixing cement concrete in mixer and place in position, vibrating, striking, curing taxes and royalty all complete for concrete cradle for dia from 150mm to1200mm NP2 pipe laying

6434

-

-

... More
DDC- 32

2

-

-

... More
Outgoing

-

-

-

... More
Supplying and laying 50 mm X 6 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection / terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) as per directed by Engineeer in Charge (For AC Plant Room - Srvice Building II )

280

-

-

... More
(vii) 0-200 A Ammeter with ammeter selector switch & 200/5 CT's - 03 Sets.

-

-

-

... More
Providing & Fixing PVC handle of approved design & make close & lock of approved design & make for aluminium casement window Left & Right operation with necessary screw etc. complete in all respect and instructions of the Engineer in charge .

8687

-

-

... More
Bus Bar

-

-

-

... More
VAV-04-1F-B 3915 1175

1

-

-

... More
2 Sets of400/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Supplying, installation, testing & commissioning of CAT6A Patch Cord (Rack End) as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

7070

-

-

... More
(ix) R,Y,B indication LED light with 2A MCB - 1 Set

-

-

-

... More
2 nos. 150A 4P MCCB Thermomagnetic controlled.

-

-

-

... More
110mm diameter

362

-

-

... More
(i) 30 HP

4

-

-

... More
(viii) R,Y,B indication LED light with 2A MCB - 1 Set

-

-

-

... More
(viii) 1020 15

29

-

-

... More
VAV-02/03/04-3F-F 4360 1308

3

-

-

... More
(ii) 110 mm diameter.

86

-

-

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire [Tunner Lighting Circuiting]

600

-

-

... More
Supplying, fitting, fixing and lowering inside the tube well Submersible pump set having spring loaded non return valve having discharge capacity & pumping head as stated below, directly coupled with submersible motor of suitable HP capable to give required discharge suitable for operation within 340 - 400 volts (plus minus 8%), 3 phase, 50 cycles, AC supply, including cost of G.I stranded wire suspension from clamps at top of well to safety support below Submersible pump . The materials of pump - C.I. Casing , Chromium Steel Pump Shaft, Bronze Impeller, approved make Pump and Motor set of same duty conditions as per direction of Engineer-in-charge. (Note: the specialist bore well vendor has to quote for both alternatives given below. Any one or both of the alternatives will be operated as per site conditions)

-

-

-

... More
Providing 125mm thick reinforced designation 75 A brick work in C.M. ( 1 : 4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding cost of reinforcement) all complete as per building specification and direction of E/I.

47318

-

-

... More
Supplying, installation, testing & commissioning of CAT6A (10Gig) 4 Pair UTP Solid Cable, 23AWG cable (Blue) as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

1167540

-

-

... More
(d) 50 mm dia pipe

800

-

-

... More
i) Feed Pump for Water Softening Plant (2W +1S) 25cum/hr at 35 Mtrs head

2

-

-

... More
For 150mm dia Pipe Class K-9 pipes.

5376

-

-

... More
4 Strip aluminium bus bar of 400 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
Supply, installation, testing and commissioning, of PLASTIC TYPE wall/window type exhaust propeller fan with low speed, elegant looking, low speed, auto matic type louver, ‘B’ insulation, IP- 40 Motor,, support, pressed steel wall frame, vibration isolators, for use on 220/240 volts, single phase, 50 Hz, power supply with all accessories, ancillary work, sealing of remaining area with wooden work upto satisfaction of engineer incharge .Sound level should not exceed 36 dB(A) at 3m, etc. as required. As Direction of E/C PROPELLER FAN ( PLASTIC)

-

-

-

... More
Selected cooling tower shall be certified for test procedure as per CTI ATC–105 and CTI STD–201

-

-

-

... More
VAV-02/03-1F-B /VAV-10-3F-G 4585 1376

3

-

-

... More
1 no. 20A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Providing P.C.C. M-100 with nominal mix of (1:3:6) in foundation with approved quality of stone metal grade-III (50mm to 25mm size) Clean coarse sand of F. M. 2.5 to 3 including screening, shuttering mixing cement concrete in mixer and placing in position,vibrating,striking,curing,taxes and royalty all complete as per building specification and direction of Engineer-in-Charge.

16385

-

-

... More
Supply of Network Switch : 16 port layer 2 switch with 10/100/1000 Managed Switches with IP multicast snooping and data-driven IGMP support and with two 1000baseT single mode FO uplink ports (with Fiber Module ) and all related termination accessories as per site specific System requirement. Price should include any other accessories required to complete the system configuration as per vendor specific requirements i.e. Power supplies, fiber converters, LIUs, Specific System cables, patch cords, labels, pigtail cables, etc. to complete the installation successfully as per directed by Engineer in Charge..

8

-

-

... More
Providing, and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes SDR11/sch40 , having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete . as per direction of Engineer-in-Charge (External work)

-

-

-

... More
Providing & fixing Floor spring SS material & SS finish for weight upto 80kg with necessary nuts screw etc. for flush Door shutter of approved Make complete in all respect as per direction of Engineer in Charge.

12

-

-

... More
Extra for Labour Charges for lowering down in foundation Reinforced Cement Concrete of any grade

18944

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
(ii) HRU-LGF-06- 1850 CMH Ceiling Suspended

1

-

-

... More
Close timbering in trenches including strutting shoring and packing cavities (whenever required) for each additional depth 1.5m complete as per specification and direction of E/I (Measurement to be taken of the face area timbered)

12762

-

-

... More
Applying priming coats with primer of approved brand and manufacture having low VOC(Volatile Organic Compound) content :With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre

712

-

-

... More
Extra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part there of.

11748

-

-

... More
iii) Irrigation pumps A set of two nos of Irrigation Pumps having discharge capacity of each pump approx.25 cum/hr at 35 m. pumping head (1 working, 1 standby) Suction from Raw water Reservoir delivery to Irrigation line at ground level.

2

-

-

... More
Outgoing

-

-

-

... More
VAV-08-1F-H 2000 600

1

-

-

... More
Capcaity ( CMH) Static Pressure ( mmof H2O)

-

-

-

... More
Providing & Fixing Tower Bolt Brass material & Brass antique finish 600mm Longx 20mm dia for Panelled Door Shutter with necessary screw etc. complete in all respect as per direction of Engineer-in-charge.

64

-

-

... More
Bus Bar

-

-

-

... More
(iii) 25.4 mm

36

-

-

... More
VAV-01-2F-H 2550 765

1

-

-

... More
VAV-01-1F-A 1110 333

1

-

-

... More
Supply of LED Recessed Downlighter with pressure die cast housing. Nominal system lumen output of 1200(±10%) lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 5700k or 6500K, CRI80 and Standard Deviation Colour Matching (SDCM) =3 to =5. The luminaire shall meet IP20 rating with THD10% and PF 0.9. The luminaire housing should made of pressure die cast aluminium .The total power consumption should be with in 10W to 15W (including driver). Similar to Philips Make GREENPERFORM SLEEK "DN 296B LED12S-6500 PSD WH" or eqiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification Required: LM 79 & LM 80 . Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement. as per direction of Engineer-in-charge.

210

-

-

... More
Supplying, installing, testing and commissioning of 4:1 Switcher It should Allows up to four HDMI A/V sources to be connected to one HDMI display. It should Quick and easy switching between HDMI sources via front panel pushbuttons, RS-232 or IR Remote control. It should support long distance transmission up to 15 m (24 AWG). It should have Supports 340MHz bandwidth for ultrahigh 4kx2k video. It should support HDMI (3D, 4KX2K,Deep color) and should be HDCP 2.2 compatible. it should have Auto switching modes for auto port selection. it should support Max. Data Rate 9 Gbps (3 Gbps Per Lane). it should have LED indication of video source devices. it should support Max. Pixel Clock 300 MHz. It should support Dolby True HD and DTS HD Master audio. It should have Built-in bi-directional RS-232 serial port for high-end system control. it Supports IR extension using a IR extension cable. It should Instant switching between HDMI input sources. "it Supports resolutions of up to Up to 4096 x 2160 / 3840 x 2160 @ 60Hz (4:2:0); 4096 x 2160 / 3840 x 2160 @ 30Hz (4:4:4)." It should support Operating Temperature 0-50°C. Storage Temperature -20 - 60°C. Humidity 0 - 80% RH, Non-Condensing. It should support I/P rating 100-240 VAC; 50-60 Hz; 1.0A. Consumption 120 VAC, 36.6W; 230 VAC, 37.5W as per directed by Engineer in Charge.

1

-

-

... More
VAV-07-1F-G 3145 944

1

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Supplying & Installing GRC Bracket (500 x 450 x 150mm) at site as per drawing and site requirements/ measurements and as per approved finish , with sealers & hardwares required, all in accordance with the manufacturer's specification & conforming to indian standards, along with submission of the shop drawings for approval, complete in all respects as per direction of the Engineer In charge.

10400

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

3856

-

-

... More
a) 11 KW - 02 No.

-

-

-

... More
2) Fan shall operate based on the CO sensor input, that has been taken care in the BMS system.

-

-

-

... More
(i) 100 mm width X 50 mm depth X 1.6 mm thickness

240

-

-

... More
Cast steel non return valves 50mm dia

8

-

-

... More
Door frame for Fire rated Glazed Door :-Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet (Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fasteners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).

272

-

-

... More
Hinges for Fire rated Glazed Door :-Supply SS Ball Bearing Hinges SS Ball Bearing But Hinges 100X 75X3 MM 4330 for fixing of fire rated glazed shutter.

320

-

-

... More
Supplying, installing, testing and commissioning of Bulk cables and connectors with LAN I/O ports for VC and requisite UPS power point for rack as per directed by Engineer in Charge

1

-

-

... More
CHILLER PLANT MANAGER Supply, installation, testing & commissioning of chiller plant manager as per above chillers requirement. The plant manager shall be suitable to monitor and control all chillers, primary, Secondary, condenser water pumps, cooling towers,motorized valves in plant room to provide the plant operator with control, monitoring, and management information being proposed by the tenderer and all suitable modules ( I/ O summary etc. as required and as per specification), valves, shall have to be provided so individual Micro Processor controlled panels of machines can be synchronised for chillers, pumps,cooling tower,Motorised valves operation and to enable sequential operation to achieve equal operating time and take care of load patterns and shall be as per specification. Number of tags and display shall be sufficient for project with 20% spares As Direction of E/C

2

-

-

... More
VAV-02-GF-D 2850 855

1

-

-

... More
(f) 65 mm nominal bore.

2

-

-

... More
Supply, Installation, Testing and Commissioning of Recess LED 595 X 595mm fitting made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Diffuser, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) =100lumens/watt, Life of fixture 50000hrs@L70%, Lumen maintenance, CCT 5700k or 6500k , CRI 80, PF 0.95, an operating Voltage Range of 140 - 270 V. Minimum glare office compliant with UGR19. The total Power Consumption should be within 30W to 40W (including DALI driver), Minimum system Lumens 3600. Philips Models RC380B LED 36S PSD W60L60 OD OC or eqiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification Required: LM 79 & LM 80. Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

1391

-

-

... More
Supply, Installation, Testing and Commissioning of Recess LED 595 X 595mm fitting with Smart Pyramid Optics, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) =110lumens/watt, Life of fixture 50000hrs@L70 Lumen maintenance, CCT 5700k or 6500k , CRI 80, PF 0.95, an operating Voltage Range of 220V- 240V. SDCM 4. Glare free with UGR16. The total Power Consumption should be within 30W to 36W (including driver), Minimum system Lumens 4000. Philips Model RC600B LED40S865 PSU W60L60 /6500K or equiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification Required:M 79 & LM 80 . Vendor should provide seperate BIS certifications for luminaire and Driver Seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

345

-

-

... More
Add/Deduct extra for using extra cement in the items of design mix over and above the specified cement content therein.(Extra/Less over 340kg per cum of Conc.)

7174900

-

-

... More
f) 250 mm dia - MS 10 mm thick pipe. (Welded/Flanged Joints)

6038

-

-

... More
1 set of Digital Ammeter with class-0.5 with 1 Nos. 1600/5A 15 VA CTs.

-

-

-

... More
1 No. ACB (EDO Type) microprocessor based 4P, 1600A 65 KA with O/L, S/C & E/F releases

-

-

-

... More
(ii) 40 A TP MPCB - 04 No.

-

-

-

... More
Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm. dia (WIRING )-

300

-

-

... More
(i) 50 Pascal

50

-

-

... More
Supplying, installing, testing and commissioning of 18U Rack which should have 4 nos. castors. All castors should be without any brake or any other locking mechanism Front door – Front Vented Glass door should be provided with 2 locks for the security purpose. This door should have provision to get mounted on Right or Left side of the rack front. This means that it should be possible to change the door configuration from Left to Right at site. It should also be possible to open this door by 180 Degrees to ensure proper approach to front of rack Rear door should be completely perforated to facilitate the air circulation at the maximum without offering any resistance to the same. Ideally, it should be possible to remove it easily and should have 2 locks for the security purpose. Rear doors should have provision to mount fan trays. Side Panels should be easily removable type along with the provision for locking. Ideally, the panels should have latching arrangement to facilitate easy removal and putting back the panel along with locks for the security purpose Height - The Rack should Provide 18U Usable Space Width – The rack should be 600mmW with 19” mounting provision Depth – The rack should be at least 600mmD. Usable Depth should be not less than 500mm.Load carrying capacity of rack should be 500 Kg Mounting rails (for Standard 19" mounting) should be made up of steel. (Minimum 2.0mm thickness) and should be of Multi-fold design for enhanced loading capacity and rigidity. It should have unique U Marking along with U locator notch. U Number Markings should be clearly visible even after mounting of the equipment Two Numbers 1U Cable Manager should be provided along with Metal Loops for Cable Dressing as per directed by Engineer in Charge..

1

-

-

... More
Providing and fixing Stainless steel Tower bolt approved brand and manufacture conforming to Grade-304,Strandard type with necessary nuts and screws all complete as per direction of Engineer-in-charge.

-

-

-

... More
2 Nos 12V/ 24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (25 plates 180Amp Hour capacity lead acid type - suitable for 3 consecutive cranking) as required as per specifications

-

-

-

... More
1 No. power factor digital meter 1 No. APFC relay Dual Source suitable for sequential operation of 11 Capacitor Banks

-

-

-

... More
(ix) 32 mm dia

8

-

-

... More
Providing & fixing ply board conforming to IS 303 : 1989 on Flush door including cost of adhesive, Lipping etc. of approved quality complete in all respect at any Level as per direction of Engineer-in-charge.

-

-

-

... More
FIRE RATED DOOR :-Providing and fixing of factory made Hollow metal fire rated doors as per IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI or ARAI or BFRC for maximum rating of 2hrs with vision panel. Test certificates should be available for vision lites /panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied should be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory as per direction of Engineer in Charge. Shutter-Fire Door DOUBLE/SINGLE leaf 2hrs FIRE RATED shall be 46mm thick fully flush double skin door with vision fire retardant glass. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per drawing & design with a beeding and screws from inside. The glass should be 6mm clear borosilicate fire rated glass of relevant rating of the door.(GLASS PANEL, HARDWARE WILL BE PAID IN SEPARATE ITEM.)

-

-

-

... More
GENERAL NOTES : All the below items should be as per direction of Engineer in Charge 1. All items of work under this Contract shall be executed strictly to fulfill the requirements laid down under “Basis of Design” in the specifications. Type of equipment, material specification, methods of installation and testing and type of control shall be in accordance with the specifications, approved shop drawings and the relevant Indian Standards, however capacity of each component and their quantities shall be such as to fulfill the above mentioned requirement.

-

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipment's, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 meter depth below ground level. a) For depth upto 250 meters for 150 mm dia tube well with top enlargement of 300 mm dia (upto 50 meter). All types of soil 300 mm dia

1080

-

-

... More
Smoke spill application (Exhaust fans) suitable for 250/300ºC operating temperature for 120 minutes as per standard BS EN12101-03,2015 and tested and certified by an independent international fire laboratory. The fan shall be CE marked/stamped.

-

-

-

... More
(b) 25 mm Weight not less than 375 gms

8

-

-

... More
7 no. 20A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Immersion Temperature Sensor with Thermowell

16

-

-

... More
Incoming

-

-

-

... More
Size - 1200X750

24

-

-

... More
VAV-04-1F-E/04-2F-A/02-2F-G 2950 885

3

-

-

... More
(v) 19.0 mm

518

-

-

... More
All 4 Pole ACBs should have 100% neutral rating

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
(vii) 1800 500 900

1

-

-

... More
VAV-06-3F-C 2190 657

1

-

-

... More
MISCELLANEOUS COMPONENTS

-

-

-

... More
VAV-01-2F-D 2015 605

1

-

-

... More
2 Sets ON / OFF / TRIP indicating lights with SP MCB’s.

-

-

-

... More
(h) 100 mm nominal bore.

20

-

-

... More
2 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(i) 63 A TP MPCB - 02 No.

-

-

-

... More
The noise level of the unit shall be ≤ 85 db at 1 m distance from the source in any direction

-

-

-

... More
1 Nos. 11 KV, 630A, 25 KA for 3 sec. VCB complete with the following:

-

-

-

... More
Pilot Light Red 24v DC (DC ON ) - LED type - 1 No.

-

-

-

... More
(i) HRU-LGF-07- 2200 CMH Ceiling suspended

1

-

-

... More
(i) 250mm dia

8

-

-

... More
a) 100 mm dia pipe.

60

-

-

... More
1 Set of 200/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer for chlorination chambers

-

-

-

... More
Supply, installation, testing and commissioning of 25 mm Outer dia CPVC PIPE with end caps including making air sampling opening of appropriate dia on appropriate interval and all accessories as required,(rate for area protected in sqm).

232

-

-

... More
7 no. 32A DP MCCB,Thermomagnetic controlled.

-

-

-

... More
Supply, installation, testing and commissioning of Heat Recovery Units comprising of Heat Recovery wheel having minimum 75% efficiency (with equal recovery of latent and sensible heat) supply air section with blowers and filter, return air section with blower and filter, concrete foundation/ Hanging arrangement with vibration isolator. VIbration isolatior should be selected in way that the machine vibration shall not transfer to the building structure, etc a required and as per the specifications of following capacity:- As Direction of E/C

-

-

-

... More
d) 3.7 KW - 02 No.

-

-

-

... More
7 no. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire

20920

-

-

... More
CABINET FAN :Supply, installation, testing and commissioning, of cabinet fans complete with direct/belt driven centrifugal fan, TEFC squirrel cage induction motor, heavy gauge sheet metal casing, rubber isolator mounts, concrete foundation/ hanging arrangement and other accessories, complete as required and as per specification. fan shall be AMCA certified for sound and performance. fans shall be of following capacities:

-

-

-

... More
Incoming

-

-

-

... More
Supply, Installation, Testing & Commissioning of CAT-6A Information outlet with Face Plate and Backbox, UL 94 V-0, as per Specifications as directed by Engineer in Charge

537.8

-

-

... More
(i) 300 A, 415V, 3ph, 4 wire Aluminium busbar

-

-

-

... More
(iv) 25 mm dia

143

-

-

... More
VAV-02-1F-B 5345 1604

1

-

-

... More
320 A, 36kA, FP MCCB

24

-

-

... More
(xv) AH-GF-08 16 15100 4

1

-

-

... More
Incomer

-

-

-

... More
MS Short Bend, 90 Degree, 350 mm dia

4

-

-

... More
Providing R.C.C M-150 with nominal mix of (1:2:4) in foundation and plinth with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M 2.5 to 3 including screening shuttering mixing cement concrete in mixer and placing in position, vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification & direction of Engineer in Charge.(Note:-Construction of Thrust/Anchor blocks including excavation in all types of strata )

30

-

-

... More
Providing and laying (Matt/Antiskid) Ceramic floor tiles of size as mentioned below (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make and approved colours and design, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete with all lead & lift as specified and as directed by Engineer-in-charge.

-

-

-

... More
Providing & fixing danger plates made of mild steel at least 2mm thick & vitreous enameled white on both sides & with inscriptions in signal red colour on front side as required.

-

-

-

... More
All MCCBs shall be Thermomagnetic Protection with O/L & S/C protection.

-

-

-

... More
• Power Supply: 24V AC/DC, +/- 10%

-

-

-

... More
a) 2.2 KW Motor - 06 No.

-

-

-

... More
EXHAUST PIPE BEND s per directed by Engineeer in Charge

-

-

-

... More
(ii) 200mm dia

14

-

-

... More
Waterproofing of Overhead Reservoir: Providing and laying water proofing treatment on Overhead reservoir consisting of following :-(Measurement on treated floor & wall area separately & Rate is inclusive all items) 1.Surface Preparation: All surfaces to receive the waterproofing to be mechanically cleaned properly so that there will be no dust, laitance, oil, grease etc. (To check a pond test to find out sign of seepage from soffit. On identification of week concrete, seepage through joints and honeycomb necessary grouting to be done with suitable material of approved manufacturer with their direction with contractor's own cost) 2.Coving:Coving to be done at all junctions by cutting V grooves of prescribed size and filling with cement-sand (1:4) mortar admixed with ( Top 77 / Nitobond SBR Latex/ Master Emaco SBR 2) of approved manufacturer with their direction. 3.Bore Packing: Bore packing to be done at all pipe entries with suitable material( Rep Microcrete 4/ Conbextra GP2/ Master EMACO S340) food grade certified of approved manufacturer with their direction. 4.Water proofing product:-Supply and apply on floor & wall an acrylic based, ready to use, food grade certified water proofing product of minimum thickness 2mm (Topseal 107/ Nitocote CM210/ Master Seal 550) as per approved manufacturer with their direction. 5.Covering with Screed plastering:-After curing Providing and applying 12mm thick plastering with Cement Mortar 1:4 admixed with integral waterproofing admixture ( Plastocrete Plus/ Conplast WL/ Master PEL 777) of approved manufacturer with their direction on wall & floor. 6.Finishing:-Finishing with Neat cement punning over plastering work. As per direction of Engineer in Charge

600

-

-

... More
VAV-02/03-LGF-C 4040 1212

2

-

-

... More
Bus Bar

-

-

-

... More
Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts required size complete.150 mm clamp

24

-

-

... More
Add 12 % GST (in Basic Rate must fill 12)

1

-

-

... More
Supply, Installation, Testing & Commissioning of 19", Smart Rack 42U 800mmW / 800mmD with front & rear perforated doors as directed by Engineer in Charge a] Shelf 575mmD - 1 No b[ Castor with levelling legs - 1 Set c] 230V, 90CFM Fan (Directly mounted on top) - 4 Nos d] PDU 12 x 5/15amp with 32amp MCB & indicator - 1 No, e] Cable manager 1U with PVC loops - 4 No f] BAR, EARTHING, CU, 42U - 1 No g] Hardware (20 Nos/pkt) - 3 Pkt

2

-

-

... More
Incoming

-

-

-

... More
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : (a) Incomings 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500A (b) Outgoings ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) (i) Main Fire Pump 200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. (ii) Jockey Pump 100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. (iii) Diesel Engine Control Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications.

2

-

-

... More
Interior Paint (On Gypsum Board/ Calcium Silicate Board) :- Providing and applying 1 coat of Solvent based Cement Primer and 2 coats of Matt / Gloss Finish Enamel of approved shade, complete as per manufacturers specifications, drawing & as directed by the Engineer-in-charge.

76815

-

-

... More
Bus Bar

-

-

-

... More
(General arrangement and schematic Drawings to be approved by the Deptt. before start of fabrication)

-

-

-

... More
SITC of StSt, Test Clamp,clamp with intermediate plate for round and flat conductors, StSt UNI disconnecting clamp For connecting down conductors to the earth entries With intermediate plate for Rd and Fl conductors, tested for withstnad lightning current 50KA(10/350 μs),testing according to DIN EN 62561-1, as specified in drawing and confirming to IS/IEC 62305 as per direction of Engineer-in-charge

168

-

-

... More
Supply, Installation, Testing & Commissioning of 4:1 Switcher It should Allows up to four HDMI A/V sources to be connected to one HDMI display. It should Quick and easy switching between HDMI sources via front panel pushbuttons, RS-232 or IR Remote control. It should support long distance transmission up to 15 m (24 AWG). It should have Supports 340MHz bandwidth for ultrahigh 4kx2k video. It should support HDMI (3D, 4KX2K,Deep color) and should be HDCP 2.2 compatible. it should have Auto switching modes for auto port selection. it should support Max. Data Rate 9 Gbps (3 Gbps Per Lane). it should have LED indication of video source devices. it should support Max. Pixel Clock 300 MHz. It should support Dolby True HD and DTS HD Master audio. It should have Built-in bi-directional RS-232 serial port for high-end system control. it Supports IR extension using a IR extension cable. It should Instant switching between HDMI input sources. "it Supports resolutions of up to Up to 4096 x 2160 / 3840 x 2160 @ 60Hz (4:2:0); 4096 x 2160 / 3840 x 2160 @ 30Hz (4:4:4)." It should support Operating Temperature 0-50°C. Storage Temperature -20 - 60°C. Humidity 0 - 80% RH, Non-Condensing. It should support I/P rating 100-240 VAC; 50-60 Hz; 1.0A. Consumption 120 VAC, 36.6W; 230 VAC, 37.5W as per directed by Engineer in Charge

1

-

-

... More
VAV-06-1F-F/ VAV-01-2F-F 4550 1365

2

-

-

... More
1 No. dedicated microprocessor based pump logic controller with parallel pumping software duly down loaded and capable of controlling upto 3 pumps in parallel / accepting 2 analog input from sensor / sensor less logic and should be capable of communicating with Building Management System by both hardware and software integration.

-

-

-

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of:a)150 mm dia

12

-

-

... More
B/C+TR I/C Status Relays

-

-

-

... More
LT Cable Laying Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required

-

-

-

... More
The chiller should be suitable for operating at low saturation pressure differential when the ambient wet bulb temperature falls to as low as 14 deg C during Winter particularly during night time.

-

-

-

... More
junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm center, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board

67490

-

-

... More
Supply, installation, testing & commissioning and laying on Cable Tray / Surface with Clamps, heavy duty armoured XLPE insulated and sheathed, as per ISI mark, 1100 volts grade aluminium stranded conductor cable of size as below all as specified . as per direction of Engineer-in-charge.

-

-

-

... More
Supply, Installation, Testing and Commissioning of LED 2ft Batten with a nominal system lumen output of 1150 lumens and a minimum system efficacy of 115 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 5700k or 6500K and CRI80. The luminaire shall meet IP20 rating with THD 20% and PF 0.9. The luminaire housing should made of CRCA with a PC glossy diffuser. The total Power Consumption should be within 8W to 14W (including driver). Similar to Philips Make Smart brite BATTEN "BN021C LED 10S 6500 PSU GR S1" or eqiv. Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

500

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. / PVC pipes including bed concrete as per standard design :

-

-

-

... More
Providing and fixing Water level monitor (Water Gauge) for installing on the side wall of Water Reservoir consisting of calibrated bore transparent tube, floating indicator, drainout valve etc. complete operational (for monitoringWater level difference upto 4 m). as per direction of Engineer in Charge.

6

-

-

... More
CONDENSER WATER PUMP (2W+1SB) Supply, installation, testing and commissioning of condenser water pump set each capable of delivering specified flow rate, each comprising the following and complete as per specifications As Direction of E/C

6

-

-

... More
VAV-02-GF-A/VAV-07-1F-A 2620 786

2

-

-

... More
(i) 40 4P MCCB - 07 No.

-

-

-

... More
Providing & fixing SS 304 material, SS finish 300 mm long concelled flush bolt of approved make & design fixed at bottom for Flush Wooden Door Shutter complete in all respect as per direction of Engineer in Charge.

362

-

-

... More
2 Sets of 1600 A 4P ACBs 35 KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings with electrical and mechanical interlocking arrangement with bus coupler.

-

-

-

... More
Supply, Installation, Testing, & Commisioning of Manual Release Switch

48

-

-

... More
a) 3.0 KW Motor - 08 No.

-

-

-

... More
(h) 80 mm nominal bore.

4512

-

-

... More
4 sets 150/5A CTs of 15 VA burden, accuracy class - 0.5 for metering and class 5P20 for protection.

-

-

-

... More
VAV-04-3F-F 4030 1209

1

-

-

... More
Outgoing

-

-

-

... More
Supply, Installation, Testing & Commissioning of Rack Mounted, Industrial Grade for outdoor Application, 12-port GbE Managed L2 PoE  Switch with 4 SFP Uplink Port completely as per specifications as directed by Engineer in Charge.

4

-

-

... More
Incoming

-

-

-

... More
1 Set of 200 A 4P MCCB 25 KA miroroprocessor based controlled with overload, short circuit and earth fault protections.

-

-

-

... More
supplying and Fixing following way, single pole neutral, sheet,MCB DISTRIBUTION BOARD, 240 volts,on surface/recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate ,interconnections,phosphatized and power painted including earthing etc.as required.(without MCB/RCCB/ISOLATOR)

-

-

-

... More
For size 100 mm long (OZ-TB- S6")

92

-

-

... More
Outgoing

-

-

-

... More
(h) 100 mm nominal bore.

96.38

-

-

... More
Supply, Installation, Testing & Commissioning of digital audio network server that shall be implemented on a RJ-45 connector and shall support Ethernet connection for programming and control on a RJ-45 connector. The server shall have internal DSP processing. The server shall include 4 channels of General Purpose Input and Output connection (GPIO) for sending or receiving logic signals. The programming of the GPIO ports shall be software configurable. The server shall include a RS-232 connection for control data transmission and such operation shall be software programmable. The server shall include a Universal Serial Bus (USB) connection on a standard USB-B type connector. The server shall be software configurable to stream up to 8 channels of digital USB Audio Class 1 transmission either into or out of the server or simultaneous input and output. The server shall provide 12 balanced input connections for receiving of microphone or line level analog audio signals on screw-down, removable connectors. The input connections shall include Acoustic Echo Cancellation (AEC) hardware and firmware, the parameters, routing and operation of which shall be software programmable. The server shall provide 8 balanced output channels for the transmission of microphone or line level analog audio signals on screw-down, removable connectors. Each individual channel shall have its own dedicated connection. The server shall provide front panel OLED identification of server power, status, alarm, and activity as well as system-wide alarm. The server shall be rack mountable (1RU) and feature software-configurable signal processing, including but not limited to: signal routing and mixing, equalization, filtering, dynamics, and delay, as well as control, monitoring, and diagnostic tools. The server shall be CE marked, UL listed and shall be compliant with the RoHS directive as per directed by Engineer in Incharge..

1

-

-

... More
AIR HANDLING UNIT Double Skin AHU Supply, installation, testing and commissioning of factory built, cabinet type, horizontal, floor mounted/CS Direct/Belt driven air handling units in double skin construction of following capacity at required static pressure complete with factory fabricated independent sections, housing the various components e.g. blower/plug fan, IE 2 motor suitable for operation on 415 ± 10% volts, suitable for VFD operation 3 phase, 50 Hz AC supply, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% in the supply of AHU, fire retarding canvass connection with volume control dampers, mixing chamber, copper tube, aluminium finned chilled water cooling coil,thermostat and control wiring, Thermowell for installing the BTU meter in the required AHUs at Inlet & Outlet piping, pre filters sets, drain connections , 150 mm SS Dial type Temperature Gauge glycerine filled 0-50 deg C range with SS stem & all other mounting accessories, SS thermowell of Greystone Make or equivalent., 150 mm SS Dial type pressure gauges glycerine filled, range 0-8 bar with Ball Valve, syphon tube, complete. All other parameters as per the technical specifications given in the tender. Concrete foundation with anti-vibration mountings etc. as required and as per "Schedule of equipment" and specifications. As Direction of E/C

-

-

-

... More
All Kitchen Exhaust fans should have impellers with backward curved blades, manufactured from aluminium. Fans should suitable for medium temperatures up to 120°C continuously. Motor protection by cold conductors or thermal contact, to be connected to an external motor protection device. The casing consists of an aluminium frame with fibreglass reinforced plastic corners and double skin, galvanised steel panels with a 20 mm mineral wool insulation. Panels are removable, allowing flexible ventilation solutions - the air direction can easily be changed by 90°. With quick lock access door. The MUB bottom panel is shaped as a condensate tray and incorporates a pre-mounted 1" drain plug. An isolator switch is mounted on the casing. The following standards must be considered for manufacturing of this Fans from supplier: DIN EN ISO 12100:2013 Safety of machinery - General principles for design -and risk reduction. DIN EN 60204-1:2010 Safety of machinery - Electrical equipment of machines - Part1: General requirements DIN EN 61000-6-2:2011 -Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments. • Fan shall be suitable Up to 120°C medium temperature, continuous operation • Shall have Pre-assembled isolator • Motor should be outside the air stream As Direction of E/C

-

-

-

... More
Capacity – 300 lpm, head - 15 mtr & 3 HP approx.

16

-

-

... More
Providing and fixing of raceway 225 x 38mm 3 compartment with thickness 1.5mm with coupler and fixing bracket

950

-

-

... More
Supplying & Installing GRC Column (Dia- 400mm x Ht.-4500mm) at site as per drawing and site requirements/ measurements and as per approved finish , with sealers & hardwares required, all in accordance with the manufacturer's specification & conforming to indian standards, along with submission of the shop drawings for approval, complete in all respects as per direction of the Engineer In charge .

144

-

-

... More
Particulate Matter Sensor (PM2.5)

4

-

-

... More
VAV-04-3F-G 4140 1242

1

-

-

... More
VAV-08-GF-E 2814 844

1

-

-

... More
Providing and fixing Stainless Steel ALDROP approved brand and manufacture conforming to Grade-304,Strandard ype with necessary nuts and screws etc. complete as per direction of Engineer-in-charge : I) For Size-300mm x 16mm dia.

120

-

-

... More
ACSDB-03 (F) Supply, installation, testing and commissioning of following distribution boards totally enclosed compartmentalized, cubicle floor mounted, indoor type IP:42, factory fabricated with 2 mm thick sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply suitable for 25 KA as per specifications and drawings. All Air Circuit Breakers shall be provided with Micro processor based Earth fault, short circuit and over current releases. Moulded case circuit Breakers shall be microprocessor based electronic trip. Fault level for all ACB/MCCB and bus bar shall be 25 KA, all the motor feeder shall be type-2 coordinated. ICU shall be equal to ICS=100%. As Direction of E/C

2

-

-

... More
Battery charging indication

-

-

-

... More
Third party BMS Compatibility: Hardware required

-

-

-

... More
VAV-10-1F-A/08-2F-H 2265 680

2

-

-

... More
4 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.

2

-

-

... More
Supplying, fitting and fixing Electrical Control Panel Board suitable for outdoor installation of adequate size made out of 2mm thick CRCA M.S. sheet and M.S. flat painted with suitable enamel paint fitted with required electrical accessories of approved make suitable for submersible pump - motor set, described above, including Automatic Star Delta Starter, Main Switch, Single Phase Preventer, Overload Protection Device, Water Level Controller with two probes, one for low level audible warning and one for very low level for tripping of the motor with all required electrical works, Amp. Meter, Volt Meter with Selector Switch, Indicator Lamp, on & off push button, Danger Board etc. as required. ( For (2W+1S) 3 nos of pump.) as per direction of Engineer in Charge.

16

-

-

... More
All ACB shall have Micro processor based O/C, S/C & inbuilt E/F release

-

-

-

... More
VAV-04-GF-E 1842 553

1

-

-

... More
Supply, Installation, Testing & Commissioning of Bulk cables and connectors with LAN I/O ports for VC and requisite UPS power point for rack as per directed by Engineer in Charge

1

-

-

... More
Supply, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.

22

-

-

... More
3 Core x 6 Sq.mm Cable

48

-

-

... More
(xx) AH-1F-04 21 19500 4

1

-

-

... More
VAV-04-2F-B 2935 881

1

-

-

... More
Supply, laying of 3Core X 2.5 Sq.mm PVC Insulated, Copper Power Cable with GI Armoring, complete with Compression Glands at the termination box as directed by Engineer in Charge.

9800

-

-

... More
Incomer

-

-

-

... More
Supplying, laying and fixing of std. chicken wire mesh flexible galvanized steel wire with hexagonal gaps. Available in 1 inch (about 2.5 cm) diameter, wire gauges 19 gauge (about 1 mm wire) to 22 gauge (about 0.7 mm wire). in positions at junctions of concrete & masonry works /over Dome Plastering etc. all complete as per specification, drawing and instructions of the Engineer in charge.

20000

-

-

... More
VAV-05-2F-F 3040 912

1

-

-

... More
2500 A, 50KA, IP 54

50

-

-

... More
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre

436909

-

-

... More
VAV-01-3F-G 3975 1193

1

-

-

... More
7 Sets of R, Y, B Phase indicating lights (LED Type) with 2A, SP MCB, 10KA.

-

-

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts :

146605

-

-

... More
(vi) 15.8 mm

279

-

-

... More
1 no. 1000A 4P EDO ACB, 35 KA microprocessor controlled with overload, short circuit and earth fault protections.

-

-

-

... More
VAV-04-1F-E /VAV-03-2F-B 2935 881

2

-

-

... More
VAV-04-1F-C 3220 966

1

-

-

... More
Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in door, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/I.

133.68

-

-

... More
TAG No. Cooling Load (TR) Each Air Qty (CMH) Chilled Water Coil (Row)

-

-

-

... More
Supply, Installation, Testing & Commissioning of Mullion RFID 13.56 MHz Smart Card Reader (IN and OUT) as per detailed Technical specifications with all accessories complete as required as directed by Engineer in Charge.

76

-

-

... More
2. The rate for each item of work included in the Schedule of Quantities shall, unless expressly stated otherwise, include cost of :

-

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.

-

-

-

... More
For size 250 mm long / (OZ-TB-S10")

162

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
1 no. 32A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Compressor: Single/Multiple

-

-

-

... More
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

25300

-

-

... More
900 lpm each at 35m pumping head (A set of 1 working and 1 standby pump)

12

-

-

... More
FANS:- TWO TIER CAR PARK VENTILATION Supply, installation, testing and commissioning of tube axial fan with adjustable pitched aluminium alloy impeller, TEFC squirrel cage induction IE2 motor with class 'H' insulation high temprature motor,1450 RPM direct drive arrangement, GSS/MS sheet metal casing, and other accessories as required and as per specification of following capacities as per Schedule of Equipment.As per Direction of E/I

-

-

-

... More
Providing and fixing G.I. pipes (C- Heavy) complete with G.I. fittings including trenching and refilling etc. conforming to IS : 1239. as per direction of Engineer in Charge. External Work.

-

-

-

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal

260

-

-

... More
Supply, Installing, testing and commissioning of  Router with SEC bundle with 5 year warranty as per directed by Engineer in Charge

4

-

-

... More
A set of Sump pumps (Non-clogging type) having discharge capacity of each pump approx.30 cum/hr at 15 m. pumping head (1 working, 1 standby) Suction from sumps in in Lower ground floor, delivery to surface drain at ground level. Including MCC and allied works

2

-

-

... More
65 mm nominal bore.

26

-

-

... More
4.) Fan section with DIDW backward curved fan with IE2, IP 55, induction motor, having following capacity and at specified static pressure, foundation and should be complete with as required and as per specification. Fan efficiency shall not be less than 60%.

-

-

-

... More
Supply, Installation, Testing & Commissioning of 3 Mtrs HDMI Cable : Crystal-clear video up to 4K DCI (4096 x 2160 @ 30Hz), 4K UHD (3840 x 2160 @ 30Hz), and 1080p @ 60Hz signal HDMI Ethernet Channel functionality: additional dedicated data channel supports networking HDMI (3D, Deep Color, 4K) and HDCP 2.2 compatible Gold-plated connectors for reliable transmissions as per directed by Engineer in Charge 3 mtrs in Length RoHS-compliant

3

-

-

... More
Supply, Installation, Testing & Commissioning of wireless digital Headmic Microphone with 18 or more channel, RF output 100mW or more, omni directional pickup pattern, Frequency range : 1880 to 1930 MHz, Connectivity : RJ-45, Battery backup : 17 or more hr etc and complete as required with 1 nos 2 port charger of same OEM as microphone as per directed by Engineer in Incharge..

2

-

-

... More
Liquid Flow Switch

6

-

-

... More
PILOT LIGHTS /INDICATIONS -

-

-

-

... More
Panel Light - 11 W CFL - 2 No.

-

-

-

... More
Supply, Installation, Testing & Commissioning of 5 Mtrs HDMI Cable: Crystal-clear video up to 4K DCI (4096 x 2160 @ 30Hz), 4K UHD (3840 x 2160 @ 30Hz), and 1080p @ 60Hz signal HDMI Ethernet Channel functionality: additional dedicated data channel supports networking HDMI (3D, Deep Color, 4K) and HDCP 2.2 compatible Gold-plated connectors for reliable transmissions 5 mtrs in Length RoHS-compliant as per directed by Engineer in Incharge.

6

-

-

... More
24U Network Closed Rack 600*1000, with 16 AMP PDU I(2 Nos) with C13/C19 Power socket (C13 socket 12 Nos & C19 4Nos each PDU) as per directed by Engineer in Charge

40

-

-

... More
(ii) 65 mm dia

23

-

-

... More
1 Set Breaker ON / OFF / TRIP indicating lights with control MCB’s.

-

-

-

... More
BUTTER FLY VALVE CONDENSER LINE Supply,installation,testing and commissioning of wafer type butterfly valve of rating PN16 complete with all accessories and all other parameters as per the technical specifications given in the tender. Valves 150 and above dia shall be Gear operated. Seat shall be integral moulded with EPDM. disc shall be of SS304. As Direction of E/C

-

-

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate with all lead & lift.

9971

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Supply, installation, testing, balancing and commissioning of powder coated extruded aluminium Rain protection fresh air louvers with aluminium bird screen and volume control damper as per specifications and approved shop drawings. As Direction of E/C

-

-

-

... More
Waterproofing of DOME : Providing and laying water proofing treatment on DOM consisting of following :- 1.Surface Preparation: All surfaces to receive the waterproofing coating to be mechanically cleaned properly so that there will be no dust, laitance, oil, grease etc. 2.Water proofing product:- Supply and application of water proofing OVER DOM SURFACE AREA with appropriate material (Sika lastic 560/Brushbond Roof guard of FOSROC/BASF Master Seal HLM 5000) of approved manufacturer with their direction. 3.Covering with Screed plastering:-After curing Providing only integral waterproofing admixtureSika lastic 560/WPE of FOSROC/BASF Master Seal HLM 5000) of of approved manufacturer & direction for mixing ratio. ( Note:-1. Using this admixture mixing with mortar for outside plastering work item.)

5828

-

-

... More
3KVA UPS (ONLINE), IGBT, On line double conversion, with Battery Backup for 30 Minutes as per directed by Engineer in Charge .

4

-

-

... More
LIFT NO. 30 / 31 Group of 1 No. Car (Stretcher Lift) as per directed by Engineeer in Charge.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Rack Mounted, 8 port Gigabit L2 managed PoE switch with 2 SFP Uplink / Combo Port completely as per specifications as directed by Engineer in Charge.

24

-

-

... More
Outgoing

-

-

-

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

25698

-

-

... More
Providing, fixing, testing & commissioning screwed type Cast Steel compact Pressure reducing valve of approved quality with pipes and specials including making necessary screwed/ flanged joints by providing all jointing materials including painting and testing the joints to hydraulic pressures specified for pipes all complete as per drawings and as directed by the Engineer-in-Charge to manage pressure of water, to restrict hydraulic forces by spring forces and maintains the desired pressure level in various parts of circuit as per direction of Engineer in Charge.

-

-

-

... More
80 Nb Flexible Hose pipe with AL Adopter for filling of bulk storage in BOT

2

-

-

... More
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50m and lift of 1.5m all complete as per specification and direction of Engineer in- charge(Mode of measurement compacted volume).(Note:- Filling trench, plinth & surrounding area of trenches upto Ground Floor Level as per drawing, from excavated earth obtain from earth stacking yard after cutting)

420

-

-

... More
Size - 300X400

336

-

-

... More
Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc. complete. Wedge expansion type Fastener with threaded dia 10 mm.

180

-

-

... More
One set of 0-20 amps Ammeter 96 mm x 96 mm with C.T.S. and selector switch.

-

-

-

... More
(vii) 0-63 A Ammeter with ammeter selector switch & 63/5 CT's - 04 Sets.

-

-

-

... More
Extra for Labour Charges for lowering down in foundation /lifting up , for Brick work in C.M. ( 1 : 6)

7644

-

-

... More
4 Nos. microprocessor controlled numerical relay having 3 overcurrent + 1 Earthfault with High set Element complete as marked in the drawing.

-

-

-

... More
4 Strip aluminium bus bar of 500 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
MS Short Bend, 90 Degree, 450 mm dia

4

-

-

... More
Outgoing

-

-

-

... More
11.0 Rates shall be inclusive of breaking and opening of wall, chasing of wall & floor for drain and making them good including finishing and paintaing upto client satisfaction. Cost of sealing of all air gaps opening with UL/FM approved fire sealant rate for 250C for 2 hours shall also be considered.

-

-

-

... More
LT PANEL-1 (AT SUBSTATION) as per directed by Engineeer in Charge.

2

-

-

... More
50 mm nominal outer dia .Pipes.

1121

-

-

... More
Incoming

-

-

-

... More
Auto-manual / test selector / switch - 2 Sets

-

-

-

... More
Waterproofing of Wet wall areas: Providing and laying water proofing treatment on Toilet, Pantry & Balconies Wall consisting of following :-( Rate is inclusive all items except mentioned) 1.Surface Preparation: All surfaces to receive the waterproofing to be mechanically cleaned properly so that there will be no dust, laitance, oil, grease etc. 2.Bore Packing:-Bore packing to be done at all pipe entries with suitable material (SikaRep Microcrete 4 /Fosroc Conbextra GP2/BASF Master Emaco S 340) of approved manufacturer with their direction. 3.Water proofing product:-Supply and apply water proofing coating wall upto2400mm above the final finished floor level., polymer modified product (Topseal 107/Brushbond RFX/Master Seal 550) as per approved manufacturer with their direction . 4.Covering with Screed plastering:-After curing Providing only integral waterproofing admixture (Sika Plastocrete Plus/Fosroc Conplast WL/ Master PEL 777) of approved manufacturer & direction for mixing ratio. ( Note:-1. Using this admixture mixing with mortar for backing mortar using for Dado finishing item under supervision of waterproofing agency for no damage of treated area. 2.Dado finishing will be done over sand cement mortar over water proofing surface will be paid in separate item). As per direction of Engineer in Charge

25180

-

-

... More
(viii) AHU FAN SECTION ….. 20900 ….

1

-

-

... More
Bus Bar

-

-

-

... More
3 no. 32A DP MCCB,Thermomagnetic controlled.

-

-

-

... More
a) 200 mm dia

8

-

-

... More
(xiii) AH-GF-04 37 33850 4

1

-

-

... More
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.

164

-

-

... More
4 no. 63A 4P MCCB

-

-

-

... More
(vii) HRU-1F-02- 2300 CMH Ceiling Suspended

1

-

-

... More
The component to be included are

-

-

-

... More
4 Strip aluminium bus bar of 400 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Size - 400X1200

64

-

-

... More
(j) 150 mm nominal bore.

5376

-

-

... More
Supply, Installation, Testing and Commissioning of LED based suspended standalone linear (4ft) Luminaire with extruded aluminium housing,anodized silver finish. System lumen output of 3300(±10%) lumens and a minimum system efficacy of 110 lm/W.The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 5700k or 6500K, CRI80 and Standard Deviation Colour Matching (SDCM) =3 to =5. The luminaire shall meet IP20 Rating with THD10% and PF0.9. The total Power Consumption should be within 20W to 36W (including DALI Driver). Similar to Philips Make PureLine Tapered "SP810P LED26S-6500 PSD W6L120 OD " or equiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification: LM 79 & LM 80 Certificates. Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

295

-

-

... More
Sealing of areas around the fan to make it leak proof with suitable Fire rated sealant.

-

-

-

... More
100 mm dia

64

-

-

... More
UNDER VEHICLE SURVEILLIENCE SYSTEM as per directed by Engineer in Charge.

4

-

-

... More
Design, manufacture, supplying, fixing, testing and commissioning of motor control centre for fuel pumps panel made of 14 S.W.G C.R.C.A. sheet dust and vermin proof compartmentalized construction with bus bar chambers, cable alley, cable glands plate etc as per directed by Engineeer in Charge.

2

-

-

... More
4. All Transformer Feeders of 11KV shall have suitable rating of REF relay with all necessary accessories.

-

-

-

... More
2Sets of 2500/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable etc. as required.

44

-

-

... More
2 Sets of 1000/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
(i) AH-LGF-03* 16 12550 6

1

-

-

... More
1x12.5 kVAr LT power capacitor banks with 2 No. 10 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :

-

-

-

... More
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm

-

-

-

... More
Supply, installation, testing and commissioning of 1200 lit. expansion tank unit in MS construction as per ASME section VIII approved/stamped of minimum 125 PSI, with pressurization unit, Air vents, safety relief valve, pressure reducing valve, BMS capable IP 55 control panel, thermal insulation and necessary valve and fittings with matching flanges, drain valve etc. as required and as per specification with TRI POD grouted on PCC foudation. As Direction of E/C

2

-

-

... More
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

-

-

-

... More
b) 7.5 KW - 01 No.c) 5.5 KW - 02 No.d) 3.7 KW - 01 No.

-

-

-

... More
Providing and fixing Water Level Monitor (Water Gauge) for installing on the side wall of Water Reservoir consisting of calibrated bore transparent tube with back ground board, floating indicator, drain out valve etc. Complete operational as per direction of Engineer-in-charge..(Water level difference upto 4 m.) - For Under ground Reservoir.

16

-

-

... More
(xix) AH-1F-03* 22 21700 4

1

-

-

... More
Supply and installation of Fire Barrier compound FFSC mortar with minimum 2 hours fire rating when tested in accordance with EN 1366-3 / ASTM E 814 / UL1479 standards , for fire rated openings in floors or slabs and floors made of concrete, masonry, metal, gypsum partition, after passing service lines like Cable,Cable trays, Bus Duct or Metal pipes. The compound shall be a light weight gypsum /cementitious product and shall carry CE marking. Expanding fire stop foam with minimum 2 hours fire rating when tested in accordance with EN 1366-3 / ASTM E 814 / UL 1479, UL 723 standards, shall be used to seal areas that are highly dense or are not accessible and cannot be sealed with fire stop mortar properly. The expanding foam shall expand to fill the cavity at the time of dispensing the material and shall fully cure within two minutes after dispensing. The expanding foam shall also be repenetratable.The rate shall include backing material like mineral wool and support system or other miscellaneous items etc all complete . as per direction of Engineer in Charge.

160

-

-

... More
Waterproofing of Top of Under Pass Garden area : Providing and laying water proofing treatment on Roof Garden area consisting of following :-(Measurement on Roof floor area only & Rate is inclusive all items ) 1.Surface Preparation:All surfaces to receive the waterproofing coating to be mechanically cleaned properly so that there will be no dust, laitance, oil, grease. The mother slab has to be laid in slope to ensure proper drainage through the drain openings etc. 2.Coving:Coving to be done at all junctions by cutting V grooves of 20 mm x 20 mm and filling with cement-sand (1:4) mortar admixed with ( Top 77 / SBR Latex of FOSRO/Master Emaco SBR 2)of approved manufacturer with their direction. 3.Bore Packing:-Bore packing to be done at all pipe entries with suitable material (Rep Microcrete 4 / Conbextra GP2/Master Emaco S 340) of approved manufacturer with their direction. 4.Water proofing product:- Supply and application of water proofing inside floor & wall upto full height & cover 300mm upto outside with appropriate material of minimum thickness 1.5mm ( LASTIC 450 I/ Nitoproof 600 / Master Seal HLM 5000)of approved manufacturer with their direction. 5.Covering with Screed plastering:-After curing Providing and applying 12mm thick plastering with Cement Mortar 1:4 admixed with integral waterproofing admixture ( Plastocrete Plus/ Conplast WL/Master PEL 777) of approved manufacturer with their direction on wall & floor complete. 6. Finishing:-Finishing with Neat cement punning over plastering work.

2325

-

-

... More
Supplying, installing, testing and commissioning of 0.6 Mtrs HDMI Cable : Crystal-clear video up to 4K DCI (4096 x 2160 @ 30Hz), 4K UHD (3840 x 2160 @ 30Hz), and 1080p @ 60Hz signal HDMI Ethernet Channel functionality: additional dedicated data channel supports networking HDMI (3D, Deep Color, 4K) and HDCP 2.2 compatible Gold-plated connectors for reliable transmissions 0.6 mtrs in Length RoHS-compliant as per directed by Engineer in Charge.

3

-

-

... More
Supply, Installation, testing and commissioning of 990 litres capacity Over flow tank fabricated from 2 mm thick MS plates. Tank shall include 450 mm ID manhole cover, level indicator and flanged connection for inlet, outlet, overflow drain and probe provision for level controller as per directed by Engineeer in Charge..

2

-

-

... More
Supply, Installation testing & commissioning of Preinsulated flexible duct to be made with inner core of triple lamination of aluminum foil, polyester and Metalized Polyester film permanently bonded to a coated spring steel wire helix. Fiberglass insulation of minimum 16 kg/cu.m density, 25 mm thickness shall be wrapped over the inner core & covered with strong outer jacket cum vapour barrier made of fibre glass reinforced metalized polyester film laminate. The prices shall aslo include necessary duct supports, fittings and accessories for fixing of duct. All other parameters as per the technical specification given in the tender. The sizes of flexible duct as below

-

-

-

... More
(ii) 0-500 V Voltmeter with Voltmeter selector switch and control fuses - 1 Set

-

-

-

... More
Size- 300mmx300mm

757

-

-

... More
Providing and laying Double charge Vitrified floor tiles (Matt finished) in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% of approved make , in approved colours and design, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc...,complete with all lead & lift as specified and as directed by Engineer-in-charge.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Centralized Automation Controller with programming: "It should Supports various interface connections for hardware-software integration and the mobility of control -IR/Serial:- 4 x Programmable IR / Uni-directional RS-232 Port(2 x 4-Pole Terminal Block Connector). Serial:-4 x Programmable Bi-directional RS-232/422/485 Port (4 x DB9 Male Connector, configurable via pin assignments), 2 x Bi-directional RS-232 Port ; (2 x 3-Pole Terminal Block Connector).I/O:-4 x Programmable Digital Input / Output Channel (1 x 5-Pole Terminal Block Connector).Relay:-4 x Relay Channel (2 x 4-Pole Terminal Block Connector).VDC:-4 x 12 VDC Output Port (2 x 4-Pole Terminal Block Connector).Ethernet :-1 x RJ-45 Female, 10/100Base-T ."; It should have 1 x USB port for easy profile upload. ;It should support IR learning function for adding IR device drivers. ; It should Supports native KNX IP for building management systems. ; it should support Telnet, TCP, UDP, ONVIF, and PJLink compliant. ; It should Supports project file backup. ;It should have Web GUI for easy system configuration. ; it Supports SSH communication for data monitoring. ; it support Customizable GUI to be used on mobile devices and PC. ; it Supports ControlAssist that allows PC control (PC shutdown, media files, PowerPoint files. ; it should have Test tool to verify commands in action before uploading the profile to the Control Box ; it should have Built-in Database Generator for device driver setup and overall device management. It should have Simulator to simulate and review the customized GUI before uploading; it Support Scheduling for repeating events ; it Support Two-way communication enables user-defined event monitoring to automatically trigger the next actions

1

-

-

... More
VAV-03-3F-G 4755 1427

1

-

-

... More
(vii) 0-630 A Ammeter with Ammeter selector switch & 630/5 C.T.s - 4 Sets

-

-

-

... More
(ii) 200mm dia

40

-

-

... More
Including packing, ocean freight,insurance

-

-

-

... More
(a) 20 mm Weight not less than 250 gms

4

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
3 no. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
VAV-04-3F-C 2795 839

1

-

-

... More
VAV-02-3F-C 3700 1110

1

-

-

... More
VAV-04-1F-F 3715 1115

1

-

-

... More
Providing and fixing water level control switch assembly consisting of adjustable low level and high level actuation for auto on/off the respective motor for installing from top / side of the reservoir through sleeve of 150 mm dia on top / side of underground reservoir including flange, PVC guide tube, two numbers floats with SS wire and electric contactor including cost of control wiring from the respective motor panel to the controlling switch etc. complete operational as per direction of Engineer-in-charge..

8

-

-

... More
4mm thick ply board

1934

-

-

... More
(xiii) 21350

1

-

-

... More
VAV-04-2F-A 2960 888

1

-

-

... More
Supplying, drilling/cleaning hole and fixing Torque Controlled Mechanical Expansion Anchor HST3 of approved make, of Sizes M8, M10, M12, M16, M20, M24 of approved make.Complete as per direction of E/I

-

-

-

... More
VAV-01-1F-C 1340 402

1

-

-

... More
Supplying, fitting and fixing ground hydrant of approved make as per direction of Engineer in Charge. 15 mm dia

150

-

-

... More
6 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Controller in DG Vender Scope

-

-

-

... More
Supplying, installation, testing & commissioning of fault isolator complete with base as required.

456

-

-

... More
Size - 150X400

3906

-

-

... More
DDC- 19

2

-

-

... More
Supplying, installation, testing & commisioning of 6 Button Keypad PABPE having inbuilt proximate sensor with a White wall-wash backlight when active, pattern lockable with IP22 protection and Multiple settings on one button. Button labeling can be customised through an online configuration tool using a library of common icons. CE, RCM, FCC, ICES, EN50491-3, RoHS compliant as per direction of Engineer-in-charge

334

-

-

... More
Lot, Adequate Refrigerant charge of R-410A Gas and Oil

-

-

-

... More
(d) 50 mm nominal bore.

16

-

-

... More
Supply, Installation, Testing & Commissioning of Supply, Installation, testing and commissioning of 19", 6U/500MMD 1 SECN with front glass door cam lock as directed by Engineer in Charge, a] Power Distribution Unit (PDU) 6x5Aamp and 1.5meter feed cable and 3 pin plug - 1 No b] shelf 255m - 1 No c] Fan 90 cfm - 2 No, d] cable manager 1U pvc loops - 2 No e] Hardware pkt of 10 - 1 No

10

-

-

... More
4 Strip aluminium bus bar of 800 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
k). Phone book supported

-

-

-

... More
Type of Compressor: Twin Rotary Screw Compressor

-

-

-

... More
CONTROL PANELS (i) Supply of Electrical cum PLC Panel for given location with MCB feeders with starters for 14 No. dual speed 3 phase Jet Fan fans of 1.7/0.34 kW each,MCCB feeders. Controlled by CO Sensors, with suitable incomer MCCB, metering panel, aluminium bus bar, PLC logic controller with necessary internal control wiring etc. complete as required and as per specifications. SITC CO Sensors is in IBMS vendor scope. However, co-ordination between the panels, CO Sensors etc. as required shall be in HVAC Contractor scope upto satisfactory working. As per Direction of E/I

2

-

-

... More
DDC- 33

2

-

-

... More
1 Set of 1600A 3P ACBs 50 KA (EDO) microprocessor controlled with overload, short circuit having :

-

-

-

... More
Car area Inside:As applicable

-

-

-

... More
Installation of D.G. sets on the foundation and including civil foundation, providing necessary anti-vibration mountings battery and battery stand first filling of lub oil, first filling of diesel for testing & commissioning & necessary load for testing & commissioning.

-

-

-

... More
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only

8376

-

-

... More
Supply, installation, testing and commissioning of 2 nos. submersible sump pumps with motor in built, IP 68 enclosure, three phase 415 volt, 50 HZ, AC supply, 2850 rpm, handling particle size ranging upto 15 mm suitable for storm water drainage, with cast iron body and impeller, SS 410 shaft, 5 metre MS galvanized chain for pump lift, level controller for automatic On/Off operation, common control panel with direct on line starting for two numbers sump pumps with one working at mid level and both working at high level, timer unit for cyclic operation in each sump supplied with suitable water proof cable from panel to pump as per tender specification etc. as required all complete as directed by Engineer in Charge..

-

-

-

... More
Supplying, installation, testing & commissioning of 12 watt RGB wallwasher Light, Protection : IP65 Class 1, Input Voltage : 220V AC, Operating Voltage : 24V DC, Power Consumption : 12 watt, Beam Angle : 120 deg, Control Mode : DMX, Housing : Aluminium Alloy, Operating Temp : -20 to 50 deg, 3 pin XLR input/output,

288

-

-

... More
Supplying, installation, testing & commissioning of IP65 DMX Signal Amplifier

300

-

-

... More
Supplying, installing, testing and commissioning of 2x2 Full HD Video Wall considering 55” IPS, LED, FHD panel, Hard coating, Anti-glare surface treatment , Bezel Width: Less than 1 mm (L/T/R/B) even bezel , Brightness: 500 cd/m2 or higher, Dynamic CR: 500000:1, Built in system - 1.2Gzh Quad Core CPU, 550MHz GPU, 2.5GBDDR3 RAM & 8GB storage or higher, SRC, Typical Power Consumption 150W or less per panel, atleast 15x15 Tile Mode, Weight per panel not more than 26KG, USB Cloning as per directed by Engineer in Charge.

4

-

-

... More
Incoming

-

-

-

... More
(xi) 3.0c x 6 sqmm

160

-

-

... More
Auto-manual / test selector / switch - 2 Sets

-

-

-

... More
(v) 06 A TP MPCB - 03 No.

-

-

-

... More
1000 amps 50KA SC for 1 sec

4

-

-

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required. (For ON / OFF AHU / Presssuriazation & exhaust fan/damper etc.)

676

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Line Protection Module on all trunk line 04 Port Each as per directed by Engineer in Charge

14

-

-

... More
ELEC. WORK ACDB 01 PLANT ROOM :-Supply, installation, testing and commissioning of following distribution boards totally enclosed compartmentalized, cubicle floor mounted, indoor type IP:42, factory fabricated with 2 mm thick sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply suitable for 25 KA as per specifications and drawings. All Air Circuit Breakers shall be provided with Micro processor based Earth fault, short circuit and over current releases. Moulded case circuit Breakers shall be microprocessor based electronic trip. Fault level for all ACB/MCCB and bus bar shall be 25 KA, all the motor feeder shall be type-2 coordinated. ICU shall be equal to ICS=100% As Direction of E/C

2

-

-

... More
80 mm nominal inner dia .Pipes.

15

-

-

... More
Incoming

-

-

-

... More
Supplying and fixing modular plate and cover in front on furniture , including providing and fixing 3 No- 3 pin 5/6 A modular socket outlet and 2 No- 5/6 A modular switch, connections etc. as required.

2908

-

-

... More
SITC of Universal Clamp StSt, For cross connections, T connections and parallel connections,tested for withstnad lightning current 50KA(10/350 μs),testing according to DIN EN 62561-1, as specified in drawing and confirming to IS/IEC 62305 as per direction of Engineer-in-charge

550

-

-

... More
Providing and laying non-pressure Modified NP3 class R.C.C. pipes with spigot & Soket jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete .as per direction of Engineer-in-charge.

-

-

-

... More
Supplying, installing, testing and commissioning of wireless digital head worn Microphone with 18 or more channel, RF output 100mW or more, omni directional pickup pattern, Frequency range : 1880 to 1930 MHz, Connectivity : RJ-45, Battery backup : 17 or more hr etc and complete as required with 1 nos 2 port charger of same OEM as microphone as per directed by Engineer in Charge.

1

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
(i) 3.0c x 10 sqmm

300

-

-

... More
DDC- 25

2

-

-

... More
Drain Board for Roof Garden:-Providing & fixing Drain board of Polymer material having Thickness 30mm, weight not Less than 280gram/sqft & Surface Void area 67% proper fixing in between 2 layer of 120GSM Geotextile membrane over Roof Top Gardening area complete in all respect as per the directions of Engineer-in-Charge.

1238

-

-

... More
(vi) 0-16 A Ammeter with Ammeter selector switch & 16/5 C.T.s - 08 Sets

-

-

-

... More
VAV-03-GF-H /04-GF-H 3910 1173

2

-

-

... More
Supplying and laying of Polythene Sheet ( 400 micron) of approved quality over damp proof course or below flooring /foundation PCC in at any Level, in tie beam , at any level, at any floor complete in all respect.

247007

-

-

... More
All ACB shall have Micro processor based O/C, S/C & inbuilt E/F release

-

-

-

... More
(v) 0-300 A Ammeter with Ammeter selector switch & 300/5 C.T.s - 04 Sets

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand: 3 graded stone aggregate 20 mm nominal size).

100

-

-

... More
Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using tructural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, Gates and similar works

78724

-

-

... More
Magnetic type Flow meter with transmitter for measuring flow suitable to mount on chilled water pipe --Line Size 200 & 250 mm (For Chilled & Cooling Water)

-

-

-

... More
(xxxiv) AH-3F-06* 22 16700 4

1

-

-

... More
Supply, Installation, Testing & Commissioning of of 18 U Rack which should have 4 nos. castors. All castors should be without any brake or any other locking mechanism Front door – Front Vented Glass door should be provided with 2 locks for the security purpose. This door should have provision to get mounted on Right or Left side of the rack front. This means that it should be possible to change the door configuration from Left to Right at site. It should also be possible to open this door by 180 Degrees to ensure proper approach to front of rack Rear door should be completely perforated to facilitate the air circulation at the maximum without offering any resistance to the same. Ideally, it should be possible to remove it easily and should have 2 locks for the security purpose. Rear doors should have provision to mount fan trays. Side Panels should be easily removable type along with the provision for locking. Ideally, the panels should have latching arrangement to facilitate easy removal and putting back the panel along with locks for the security purpose Height - The Rack should Provide 18U Usable Space Width – The rack should be 600mmW with 19” mounting provision Depth – The rack should be at least 600mmD. Usable Depth should be not less than 500mm Load carrying capacity of rack should be 500 Kg Mounting rails (for Standard 19" mounting) should be made up of steel. (Minimum 2.0mm thickness) and should be of Multi-fold design for enhanced loading capacity and rigidity. It should have unique U Marking along with U locator notch. U Number Markings should be clearly visible even after mounting of the equipment Two Numbers 1U Cable Manager should be provided along with Metal Loops for Cable Dressing.as per directed by Engineer in Charge

1

-

-

... More
Upto 35 sq. mm

5000

-

-

... More
Incomer

-

-

-

... More
670 KVAR (Seleected actual Rating may be 836.5KVAR) LT Capacitor Panel-3 as per directed by Engineeer in Charge.

2

-

-

... More
Providing and fixing C.P. on brass Toilet paper holder.

699

-

-

... More
Above 35 sq. mm. and up to 95 sq. mm.

400

-

-

... More
(v) 32 mm dia

2

-

-

... More
Shoe (Plain).

-

-

-

... More
(iv) 16 A TP MPCB - 02 No.

-

-

-

... More
3 Set of 4000/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.)

-

-

-

... More
DDC- 35

2

-

-

... More
(iii) 200 mm width X 50 mm depth X 1.6 mm thickness

160

-

-

... More
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : capacity 2850 lpm at 70 m head (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55\ protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.

6

-

-

... More
Provide Acrylic Firestop Sealant FiAM in services passing through fire rated walls and floors made of concrete, masonry, metal, gypsum construction to provide up to 2 hours insulation and integrity in accordance to EN 1366-3 / ASTM E 814/ UL 2079 standards.After passing service lines like metal ducts, metal pipes. Sealant to provide sufficient water and gas tight seal apart from providing an airborne sound transmission reduction (STC of 50) and shall be tested for sound insulation. All installations to be in full accordance with the manufacturer recomendation. The rate shall include backing material like mineral wool or other miscellaneous items etc all complete .as per direction of Engineer in Charge.

-

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
(v) 0-200 A Ammeter with Ammeter selector switch & 200/5 C.T.s - 02 Sets

-

-

-

... More
5 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Providing & laying, uPVC pipes with fittings of class III (6 kg/ cm2) as per IS:4985 in exposed surface / ceiling as per drawing and specification with rubber ring and rubber lubricant,(EPDM/SBR) for all depths for pipe length suitable for rain water headers including hydraulic field testing and commissioning etc all complete as directed by Engineer.

-

-

-

... More
Supply, installation, testing and commissioning of centralised system controller for controlling the indoor units, AHUs etc. and outdoor unit operation, complete as per specifications.This unit shall be BMS compatible for datas to be integrated on central BMS system. As Direction of E/C

2

-

-

... More
8 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Outgoing

-

-

-

... More
Design, Fabricate, Supply & Fixing Stainless Steel of Grade 304 (2 mm Thick sheet)) Lettering (Hindi & English) maintained height with proportionate width as per approved design at selected Place with LED Light & fixing Arrangement at back & necessary fittings & Fixture complete in all respect.Sample Should be approved before execution as per direction of Engineer In Change. (Rate for Lighting is paid in separate items)

-

-

-

... More
VAV-06-GF-A 1818 545

1

-

-

... More
(iv) 0-16 A Ammeter with Ammeter selector switch & 16/5 C.T.s - 11 Sets

-

-

-

... More
(iv) 100mm dia

18

-

-

... More
Incoming

-

-

-

... More
Supply, Installation, Testing & Commissioning of 24 U Rack which should have 4 nos. castors. All castors should be without any brake or any other locking mechanism Front door – Front Vented Glass door should be provided with 2 locks for the security purpose. This door should have provision to get mounted on Right or Left side of the rack front. This means that it should be possible to change the door configuration from Left to Right at site. It should also be possible to open this door by 180 Degrees to ensure proper approach to front of rack Rear door should be completely perforated to facilitate the air circulation at the maximum without offering any resistance to the same. Ideally, it should be possible to remove it easily and should have 2 locks for the security purpose. Rear doors should have provision to mount fan trays. Side Panels should be easily removable type along with the provision for locking. Ideally, the panels should have latching arrangement to facilitate easy removal and putting back the panel along with locks for the security purpose Height - The Rack should Provide 24U Usable Space Depth – The rack should be at least 600mmD. Usable Depth should be not less than 500mm Load carrying capacity of rack should be 500 Kg Mounting rails (for Standard 19" mounting) should be made up of steel. (Minimum 2.0mm thickness) and should be of Multi-fold design for enhanced loading capacity and rigidity. It should have unique U Marking along with U locator notch. U Number Markings should be clearly visible even after mounting of the equipment Two Numbers 1U Cable Manager should be provided along with Metal Loops for Cable Dressing.

1

-

-

... More
Outgoing

-

-

-

... More
Supply, installation, testing & commissioning of chilled water Fan coil unit consisting Fan, Coil & Washable HDPE (high density polyethylene ) Filter with 10 micron filteration, complete with TEFC motor with minimum 4 row deep cooling coil and insulated drain pan as per technical specification. The Unit shall be operated through modulating type actuator operated through a digital thermostat having 3 speed fan switch; power On / Off switch, thermal sensor and upto 15 m of cabling from the thermostat upto the respective fan coil unit as per the technical specifications given in the tender. Price shall be inclusive of control wiring,drain pump, drain pipe with insulation, valve station, PIBCV control valve & strainer. Sound level at 1m distance shall be less than 40 dBA. All other parameters as per the technical specifications given in the tender. (i) 3.0 TR - High static. As Direction of E/C

2

-

-

... More
450 mm dia

4

-

-

... More
150 mm nominal bore.

70

-

-

... More
(i) 100 A, 415V, 3ph, 4 wire Aluminium busbar

-

-

-

... More
150 mm dia

230

-

-

... More
2 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(i) 0-63 Ammeter with Ammeter selector switch and 63/5 C.T.s -1 Set

-

-

-

... More
20 mm nominal outer dia .Pipes.

1758

-

-

... More
Each capacitor bank must have 1 set of on/off indication LED type.

-

-

-

... More
(iv) 1600 450 900

1

-

-

... More
Bus Bar

-

-

-

... More
Restricted earth fault relay with 4 CTs -1 Set

-

-

-

... More
Supply, installation, testing & commissioning of the following light fixtures complete with lamps, isolated led driver, Potted Driver for outdoor products etc complete in all respect . The product should conform to LM 79,80 standard. The product should have a constant current driver, built in heat sink. LED lamp should be certified with ENEC, Ec , IEC and KEMA.The make of the LED modules should be Sharp. supply including all accessories required for mounting at surface/ recess /wall as required conforming to relavant IS codes. as per direction of Engineer-in-charge.

-

-

-

... More
Supply, Installation, Testing & Commissioning of 2Nos. Entry sensor, 1No. Exit Sensor, 2 nos, camera, Checker plate - 40ton, submersible pump etc for UVSS in ground, complete with required accessories for installation including civil work complete with all the systems are in the scope of bidder. Sample shall be got approved by E.I.C. / consultant.:- 1set.

-

-

-

... More
42U Network Closed Rack 800*1000, with 32 AMP PDU I(2 Nos) with C13/C19 Power socket (C13 socket 12 Nos & C19 4Nos each PDU) as per directed by Engineer in Charge

46

-

-

... More
Status Indicator 12 Channel - 24V DC - I No.

-

-

-

... More
150 mm dia

106

-

-

... More
Supplying, fitting and fixing following M.S. fittings fitted with suitable Flanges at both ends with necessary Nuts, Bolts and Washers as per direction of Engineer-in-charge:

-

-

-

... More
1 Set of 100/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Outgoing

-

-

-

... More
VAV-08-GF-A 3778 1133

1

-

-

... More
VAV-02-3F-F 3370 1011

1

-

-

... More
Supplying SS 304 100x75x3mm Butt Hinge with necessary screw of approved make Flush Wooden Door Shutter complete in all respect as per direction of Engineer-in-charge.

13130

-

-

... More
(d) 40 mm nominal bore.

2

-

-

... More
CABINET MEETING ROOM : Supplying, installing, testing and commissioning of VC system like Codec, Camera and Microphone that should be from the same OEM.Full HD 1080p camera, codec, Microphone Array, cables, and remote control.It should support H.323, SIP standards for communications, H.261, H.263, H.264 AVC/ SVC, H.264 High Profile, 1080p 60 fps, 1080p 30 fps, 720p 60 fps and 720p 30fps, content sharing using standard based H.239 and BFCP over SIP at resolution HD1080p60, audio from PC used for content sharing, should transmit both people and content both simutaneously to the far end location at 1080p 30fps, should support G.711, G.728, G.729A, G.722, G.722.1, AAC-LD or better, 20kHz bandwidth with crystal clear audio and stereo sound.Automatic Gain Control and Automatic Noise Suppression. Keyboard noise reduction and instant adaptation echo cancellation. 1 x HD input for connecting main HD camera. 1 x HDMI input for connecting PC/Laptop to share HD content . 1 x Microphone Input(Support for minimum 2 mics). 1 x 3.5mm stereo line-in. 2 x HDMI output for connecting main monitor & second monitor. 1 x 3.5 mm stereo line-out. 1 x 10/100/1000 LAN port. 2 x USB 2.0 for software upgrade and connecting external devices. 1 x RS-232 mini-DIN 8-pin, should support 1080p60fps with 10x optical zoom and 65° field of view, PAN Range of +/-100°, and Tilt of +/-20°, H.323 and SIP bandwidth up to 6 Mbps, IPv4 and IPv6 support from day one, Auto Gatekeeper Discovery, IP Precedence, H.323 based Packet Lost Recovery, should support atleast 6 sites at 720p. Media Encryption (H.323, SIP): AES-128, AES-256.Authenticated access to admin menus, web interface and telnet API.Local account password policy configuration, H224/H.281, H.323 Annex Q, H.225, H.245, H.241, H.239, H.243, H.460, should support native Lync server integrations,Auto sensing power supply. 125VA @ 230V @ 60Hz.as per directed by Engineer in Charge

1

-

-

... More
Providing and laying non-pressure NP3 class R.C.C. pipes with spigot & Soket jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete as per direction of Engineer in Charge.: 100 mm dia. R.C.C. pipe

310

-

-

... More
Note: Provision shall be considered for future 2 no DG Set.

-

-

-

... More
3.5 C x185 sq mm A2XFY cable

24

-

-

... More
(iii) AH-LGF-03 (B) 7 5900 4

1

-

-

... More
NON FIRE RATED METAL(MS) DOOR :-Supplying and fixing 35mm/50mm thick (at any level) of Factory made MS non fire rated Door Shutter having 1.2 mm thick sheet bothside, C channel supported by sufficient stiffner as per drawing with Frame Pressed Galvanized steel confirming to IS 277 having 1.6mm thick sheet including Transfer grill,vision panel, finishing with paint over primer fittings & fixture and including all necessary Hardware ,as per Drawing & Design with the direction of Engineer in Charge complete in all respect as per direction of Engineer in Charge. (Sample of each Door Should be approved before procurement)

-

-

-

... More
French spirit polishing :Two or more coats on new works including a coat of wood filler.

21039

-

-

... More
VAV-08-3F-H 3413 1024

1

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
VAV-03-3F-H 2175 653

1

-

-

... More
1 No. 100 Amps TP MCCB,50 KA, Thermomagnetic Protection controlled.

-

-

-

... More
Chiller shall be AHRI certified

-

-

-

... More
Water temperature indication

-

-

-

... More
Top roof should be well ventilated, especially with ventilation provided on the vertical side of the roof to enhance the hot air outflow while in operation. Roof should also have provision to mount atleast 4 nos. of 90 CFM cooling fan trays and there should be space for the cable entry from the top. Thickness of powder coating should be 60 microns or more. Colour of the cabinet should be Black The structure and all its components should be made from CRCA Steel Material – at least 1.2mm thick The rack should be provided with 1 Heavy Duty Shelf of 390 mm Depth. Vertical power distribution units provided should have 6 outlets of 5/15 amp capacity. All cables used should be of ISI grade with 2.5sq mm cross sectional area. All the connecting ends must be tinned so as to avoid any loose wire strands. Rack should have the appropriate mounting provision for the multiple of these PDUs at the rear of the rack. Each Rack should be provided with one numbers of such power distribution units. Certifications: RoHS

-

-

-

... More
(xiv) 0-10 A Ammeter with ammeter selector switch & 10/5 CT's - 10 Sets.

-

-

-

... More
Providing and fixing ISI marked stainless steel Handle approved make superior quality with necessary screws etc. complete as per direction of Engineer-in-charge: (a) 150 mm long D type

532

-

-

... More
Piping for Humidifier Inlet and condensate drain 50 mm (Insulated with 9mm thk Nitrile rubber insulation)

-

-

-

... More
(b) Supply installation testing and comissioning of back draft dampers manufactured from Aluminium extrusions with blade pivot mechanism incorporates nylon bushes and stainless-steel pins. As Direction of E/C

4

-

-

... More
Supply,installation,testing and commissioning of Gun metal gate valves as per IS -778, Pressure Class -2, screwed in Bonnet, Integral seat, solid wedge, with asbestos/ Hemp & Jute gland packing etc. of PN 16 Rating with insulation . All other parameters as per the technical specifications given in the tender. As Direction of E/C

-

-

-

... More
Supplying dividing Aluminium strip fitted and fixed with cement mortar (1:3) in mosaic or patent stone floor, dado etc. complete as per direction of the Engineer-in-charge. Aluminium - 25 mm. wide & 2mm. Thick with all lead & lift for cement concrete flooring as per direction of the Engineer-in-charge.

1000

-

-

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)

388

-

-

... More
(vi) 0-150 A Ammeter with ammeter selector switch & 150/5 CT's - 02 Sets.

-

-

-

... More
2 nos. 100A 4P MCCB

-

-

-

... More
Labour charges for antiskid groove 3 nos. in treads of steps of Kota stone/Granite Stone as per design as specified and as directed by Engineer-in-charge.

21870

-

-

... More
MDB - 1 & MDB - 2 (AT ELECTRICAL ROOM) as per directed by Engineeer in Charge.

4

-

-

... More
Non-Stop Floors: 0

-

-

-

... More
(iii) Dia 150mm

478

-

-

... More
1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
1 Set of 200 A 4P MCCB 25 KA miroroprocessor based controlled with overload, short circuit and earth fault protections.

-

-

-

... More
Supply, Installation, Testing and Commissioning of LED postop luminaire, housing made of pressure die cast aluminium with specially made DS optics and clear bowl diffuser with GI pole height 3.0M above ground Lev. The minimum lumen output of the luminaire should be 3000lm and maximum wattage should be 39W(±10%) (including all losses). The luminaire should be IP65 protected. The luminaire should have a CCT 4000k, CRI 80, PF 0.95, an operating Voltage Range of 220V- 240V, Standard Deviation Colour Matching (SDCM) =3 to =5. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The lumianire should be conform to EN:60598-1:2011, EN:60598-2-3:2006,EN:55015:2011, EN:61547:2009, EN:62493:2010, EN:62471:2010. The lumianire should be similar to Philips BDP001 ECO40/840 DS PCC GR MSP 62P or eqiv. Certification Required: LM 79 & LM 80 .Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

180

-

-

... More
(c) ON/OFF push button with control fuses – 1 Set

-

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
(ii) 250 mm dia

173

-

-

... More
Bus Coupler

-

-

-

... More
3 Set of 40/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
VAV-04-1F-G 1400 420

1

-

-

... More
(xxix) AH-2F-05 22 18900 4

1

-

-

... More
Shoe (Plain). (iii) 160 mm diameter.

312

-

-

... More
Supply, installation, testing and commissioning of GI Multi-leaf Fusible link Fire Dampers complete with chrome plated spindles in self lubricated bronze bushes, linkages etc. complete as per specifications. As Direction of E/C

185

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) (Civil related PHE Items)

56

-

-

... More
1 no. 20A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
(i) 5600 CMH at SP at 30 mm WG

2

-

-

... More
Providing Tor steel reinforcement of 8mm dia to 10mm dia rods as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position (excluding carriage of bars to work site) all complete as per building specification and direction of E / I. {Fe 500 Only valid for TATA(Tiscon), SAIL, JSPL, Electrosteel Steel Ltd Bokaro and Vizag (RINL)}

12611.7

-

-

... More
Supply, Installation, Testing & Commissioning of 15 Mtrs HDMI Cable : Crystal-clear video up to 4K DCI (4096 x 2160 @ 30Hz), 4K UHD (3840 x 2160 @ 30Hz), and 1080p @ 60Hz signal HDMI Ethernet Channel functionality: additional dedicated data channel supports networking HDMI (3D, Deep Color, 4K) and HDCP 2.2 compatible Gold-plated connectors for reliable transmissions 15 mtrs in Length RoHS-compliant as per directed by Engineer in Incharge.

1

-

-

... More
Note: All metering current transformers shall be Class 0.5, 05 VA, cast resin type.

-

-

-

... More
(viii) 16700

1

-

-

278

-

-

... More
Supply, Installation, Testing & Commissioning of Access control management software with required Licences and as per detailed Technical specifications with all accessories complete as required. Integrators to ensure compatibility with the CCTV NVR Software. also, Door Controller and ACS Software should be of same make as directed by Engineer in Charge.

2

-

-

... More
Reset PB Black -Test Push Button with 1 NO Contact - 1 No.

-

-

-

... More
Supplying, installation, testing & commissioning of 90 watt RGB wallwasher Light, Protection : IP65 Class 1, Input Voltage : 220V AC, Operating Voltage : 24V DC, Power Consumption : 90 watt, Beam Angle : 10 deg, Control Mode : DMX, Housing : Aluminium Alloy, Operating Temp : -20 to 50 deg, 3 pin XLR input/output,

144

-

-

... More
VAV-02-GF-F/03-GF-F/04-GF-F 2997 899

3

-

-

... More
65 mm dia

48

-

-

... More
Providing, installation, testing and commissioning of 'Silent Type' Diesel Generating set conforming to latest environment protection regulations for emission and noise level having Prime Power Rating of 2250 KVA, 415 Volts at 1500 RPM, 0.8 lagging power factor at 415 volt suitable for 50 Hz, 3 phase system & for 0.80 Load Factor including all wire & control cabling and consisting of the followings s per directed by Engineeer in Charge:

-

-

-

... More
Providing & fixing 200mm Long Pull Handle for FRP Door & Flush Door Shutter Material SS304 & SS finish complete in all respect as per direction of Engineer in Charge.

482

-

-

... More
(iii) 425 10

39

-

-

... More
3 no. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Surface mounted, rounded, Led Luminaire with 15w Led lamp, Life of fixture 50000hrs@L70 Lumen maintenance, Color Temp. =5700, CRI 80, PF 0.95, THD10%, 2.5KV Surge protection, an operating Voltage Range of 180 - 240 V, Standard Deviation Colour Matching (SDCM) 4, Minimum system Lumens 1500Lumens, similar to Bajaj Cat. no. BGSLO Sleek surface 15WH RD or equiv. Sample luminaire shall be got approved by Engineer-in- charge / consultant.

60

-

-

... More
3 Sets ON / OFF / TRIP indicating lights with SP MCB’s.

-

-

-

... More
Supplying, fitting and fixing Water purifier for drinking purpose of storage capacity not less than 7 liters,with RO+UV+UF+TDS controller water purification system, purification capacity upto 15lph, max duty cycle 75ltrs/day, fully automatic auto start and auto off with computer control system, TDS control system having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar as per direction of Engineer in Charge to Aquaguard/ Kent or similar approved make - (Model - KENT Super Star RO+UV/UF+TDS water purifier).

144

-

-

... More
Bus Coupler

-

-

-

... More
Water pressure sensor

2

-

-

... More
b) AIR SEPERATOR Supply, installation, testing and commissioning of minimum 125 PSI Centriufugal / Micro bubble air and dirt seperator with matching flanges of 300 dia , valves, Auto Airvent, Insulation, as required and as per specification on tri pad stand grouted on PCC foundaton. As Direction of E/C

2

-

-

... More
(ii) 38 mm Width

23

-

-

... More
1 No. 40 Amps TP MCCB,50 KA, Thermomagnetic Protection controlled.

-

-

-

... More
Supply, Installation, testing and commissioning of electrical driven rotary gear-pumps suitable for pumping of bulk storage to buffer tank as per directed by Engineeer in Charge.

4

-

-

... More
Incoming

-

-

-

... More
Dedicated plant manager software having inbuilt application. Integrators/Modems/Gateways for software open protocol (BACNET) compatible Integration of all above equipments with BMS etc. complete as per specifications and drawings Providing, installation, testing & commissioning of programmable controller (imported UL listed) having processors of 32 Bit 50 MHZ, (LON CHIP) open protocol ( BACNET/Modbus) compatible, controller for Pumps, Cooling towers. The Controller shall support easy graphical Programming and shall be able to store the programme in the controller rather than store in the PC. it should include Lockable Mounting cabinets duly powder coated, connecter strip, internal wiring etc. Supply, installation ,testing and commissioning of Field devices including rigid GI conduit, control and signal cables, Lan cables etc CPM should be able to communicate/interface with main IBMS. All required software and hardware to be provided.

-

-

-

... More
(vi) Star Delta / DOL starter with ON/OFF indicating light, ON/OFF push buttons, control fuses, timers, contractors, overload relay with built-in single phase preventor, control fuses, wiring, interconnections suitable for following rating motor.

-

-

-

... More
Making soak pit 2.5 m diameter 3.0 meter deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

32

-

-

... More
Supply, Installation of Warning Signs and Plates for Inside Room and Outside Room application. as per direction of Engineer in Charge.

48

-

-

... More
BACnet / MOBUS / Open protocol compatible communiction card for integeration with BMS

-

-

-

... More
80 mm dia

36

-

-

... More
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.

900

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Providing & fixing Door Stopper SS material body & finish supported at floor with necessary screw etc. for flush Door shutter of approved Make complete in all respect as per direction of Engineer in Charge.

1319

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

24376

-

-

... More
Providing and laying coving ( Hallor ) the junctions of the Vertical wall and Roof slab with fillet of size 150mm x 150mm with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) and admixed with waterproofing compound of approved manufacturer's specificationas directed by the Engineer-in-charge complete in all respect.

2126

-

-

... More
Supplying, installation, testing & commissioning of CAT6A 2 Port Faceplate, Back Box & Key Stone with Labeling as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

6574

-

-

... More
(ii) 40 A TP MPCB - 04 No.

-

-

-

... More
50 mm dia vent pipe

24

-

-

... More
DOOR SHUTTER GLASS PANEL :- Designing ,Providing, fabricate and fixing glass paneling in paneled shutters for doors, (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Paneling for paneled shutters 12 mm thick : Beveled clear glass of approved make all complete as per direction of Engineer-in-charge

59

-

-

... More
(ii) 110 mm diameter.

578

-

-

... More
Bus Bar

-

-

-

... More
Outgoing

-

-

-

... More
1 Set of 63/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Supplying, installation, testing & commissioning of 6Core Multimode Indoor (OM4) Optical Fiber cable as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

32400

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
Supply, Installation, Testing and Commissioning of LED Ground Mounted Bollard (0.8m height) with a system lumen output of 300 lumens and a minimum system efficacy of 35lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI75. The luminaire shall meet IP65 with THD 20% and PF 0.9. The luminaire housing should made of pressure die cast aluminium with polycarbonate diffuser. The total Power Consumption should be within 6W to 12W(including driver).BIS certification to be provided seperately for luminaire and Driver. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameter s. Similar to Philips Make LED BOLLARD II "BCP151 LED3000/WW PSU GR" or eqiv. Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

540

-

-

... More
2 Sets ON / OFF / TRIP indicating lights with SP MCB’s.

-

-

-

... More
(i) Minimum 18 mm on Supply air duct

21756

-

-

... More
(xi) Dia 25mm

142

-

-

... More
11 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Supplying, Testing and Commissioning of the Graphical Software providing the facility to create / provide the following, static and animate the Graphics, Navigation between pages, display of logs, changing the time zones, popup alarms, with Unlimited number of user license configurable password protection for Building Automation System as per Specifications. The BMS platform shall natively support standard communication protocols such as Lontalk® /BACnet™/Lonwork etc. The Software should be capable enough to transmit messages on Email Alerts. The software should be Web Based Software Required to remotely monitor the system for unlimited users. This Software should have the following Key features 1. WEB BASED TOOL. NO ADDITIONAL SOFTWARE REQUIRED. 2. EMAIL / SMS OPTION AVAILABLE 3. MULTIPLE DATABASE SOURCES / SITE CAN BE INTEGRATED. complete as per tender specification.

-

-

-

... More
16/25 amps

18

-

-

... More
Bus Bar

-

-

-

... More
35mm thick Metal Door SIZE 600MM(W)X2250MM(H) Single Shutter,frame Including Hardware.(3nos. 100mmx75mmx3mm MS Butt Hinge, 2nos.250mm Long D-Type MS Handle Fabricated MS 20mm dia ROD, 2 nos.250mm Aldrop Finished painted as per approved colour) complete in all respect.

295

-

-

... More
Note -

-

-

-

... More
VAV-05-2F-C 2122 837

1

-

-

... More
Bus Bar

-

-

-

... More
DDC- 43

2

-

-

... More
Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately).

-

-

-

... More
150 mm diameter S.W./PVC pipe

2287

-

-

... More
7 no. 20A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Capacity 0-60 Cum/ hr/ Pressure Gauge - 6 Nos or as per approved drawing/ Range 0-7 kg/sq cm / Inter Connecting Pipes, Pipe fittings and valve etc. - 1 lotCivil work like foundation of pumps, motors, vessels and other ancillary works like drains etc. within battery limit - 1 Job

2

-

-

... More
14 Sets of 40A 4P MCBs, 10KA

-

-

-

... More
Chilled Water Outlet Temperature: 6.66 deg C

-

-

-

... More
(c) ON/OFF push button with control fuses – 1 Set

-

-

-

... More
microprocessor based Genset Controller with communciation cables etc. as required and degree of protection IP:54 & all relays shall be microprocessor based comprising of the following:

-

-

-

... More
VAV-05-3F-G 1935 581

1

-

-

... More
Incomer

-

-

-

... More
Supply, Installation, Testing & Commissioning of 8 Port Gigabit L2 managed switch, PoE+, 180 Watt, with 10/100/1000 Mbps POE Ports - 8 Nos and 2 Nos. Gigabit SFP/Combo Port Loaded, Switching Capacity of 20 Gbps, Input Power 100-240 VAC, 50~60 Hz. Operating Temperature 0°C to 50°C, Fanless Design with required all related accessories to complete with all the systems.

-

-

-

... More
Ceiling Mounted Batten Type Led Luminaire with 1x18w Led Tube Light, Life of fixture 50000hrs@L70 Lumen maintenance, Color Temp. =5700, CRI 80, PF 0.95, 2.5KV Surge protection, an operating Voltage Range of 180 - 240 V, Standard Deviation Colour Matching (SDCM) 4, Minimum system Lumens 1800Lumens, similar to Bajaj Cat. no. BLRB 118 +1Nos LED tube light or equiv. Sample luminaire shall be got approved by Engineer-in- charge / consultant.

208

-

-

... More
VAV-05-GF-E 1048 314

1

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
a) 11 KW - 03 No.

-

-

-

... More
Providing 12mm. thick cement plaster (1:3) and 1.5 mm cement punning with clean coarse sand of F.M 1.5 including screening, curing, with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of the Engineer-in-charge.

8652

-

-

... More
(c) 32 mm Weight not less than 600 gms

24

-

-

... More
Providing Tor steel reinforcement of 12mm dia to 32mm dia rods as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position (excluding carriage of bars to work site) all complete as per building specification and direction of E / I. {Fe 500 Only valid for TATA(Tiscon), SAIL, JSPL, Electrosteel Steel Ltd Bokaro and Vizag (RINL)}

21267.1

-

-

... More
(i) 150 mm nominal bore.

4

-

-

... More
(iv) HRU-GF-04- 1950 CMH Floor Mounted

2

-

-

... More
(i) 100 A, 415V, 3ph, 4 wire Aluminium busbar

-

-

-

... More
Providing, fixing, Chlorinated polyvinyl chloride (CPVC) pipes SDR 11/sch40 , having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1m spacing . This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work - Exposed on Wall

-

-

-

... More
4 Core x 2.5 Sq.mm Cable

600

-

-

... More
Shunt trip coil. - 3 Sets

-

-

-

... More
Providing double flange Sluice valve confirming for IS-2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps transportation etc. complete F.O.R rates inclusive all taxes.For 80mm dia Pipe With-out byepass arrangement-PN-1.6

148

-

-

... More
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.

288

-

-

... More
25 mm nominal outer dia .Pipes.

11

-

-

... More
VAV-06-GF-E 3370 1011

1

-

-

... More
2 Sets of 4000 A 4P ACBs 50 KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings with ATS arrangement

-

-

-

... More
VAV-07-GF-D 4506 1352

1

-

-

... More
Outgoing

-

-

-

... More
VAV-05-GF-A 1810 543

1

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

29171

-

-

... More
8mm dia rebar at 160 mm depth

4

-

-

... More
Providing and fixing in position glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) For Float glass panes 5 mm thick glass pane (weight not less than 12.5 kg per sqm)

70

-

-

... More
1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
(ii) Storage capacity of 15 Litres with vacume release valve and Model No. CDR 15V/H or approved equivalent make / model.

109

-

-

... More
(vi) 600 mm width X 75 mm depth X 2.0 mm thickness

1600

-

-

... More
80 mm diameter UPVC. pipe

1281

-

-

... More
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface inluding preparing the plasterecl surface by rubbing smooth with pumice stone or fine sand paper applylng putty wherever required scaffolding washing of floors and taxes all complete as per buiiding specifica tionand drrection of E/1.

46554

-

-

... More
Incomer

-

-

-

... More
2 Sets of 1000 A 4P ACBs 50 KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings.

-

-

-

... More
Supplying, installing by suspension on ceiling/along the wall, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/ sq. cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every meter, adopter box and copper flexible for joints, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required

-

-

-

... More
PMDB-LGF (POWER MAIN DISTRIBUTION BOARD) ( LOWER GROUND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 2 as per direction of Engineer-in-charge

2

-

-

... More
2 no. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Work station for monitoring UVSS (Intel i3,8GB DDR3,2TB, 2.66 Ghz , 4 Mb L2 Cache, Memory 16GB, HDD 2TB, 21 inch LED Monitor, Optical mouse, Keyboard, preloaded Windows Server (latest version) :- 1no.

-

-

-

... More
(e) 40 mm nominal bore.

1007

-

-

... More
alternative B): Discharge capacity 15 cum per hour at a pumping head of approx. 75 meters head.

6

-

-

... More
(i) 1900 600+ 800 900

2

-

-

... More
VAV-03-1F-G 2600 780

1

-

-

... More
200 mm dia. R.C.C. pipe.

326

-

-

... More
Supply, Installation, Testing and Commissioning of LED indoor surface mounted rounded ceiling light suitable for general lighting. Luminaire should have polycarbonate cover with diffused optics. The luminaire should have CRI 80 and CCT of 5700k or 6500K. The luminaire shall be compliant with IP20 classification.The fixture should have a minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 1200 lumens. The total Power Consumption should be within 10W to 16W (including driver). The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 30k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.9.  BIS certification to be provided seperately for luminaire and Driver. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Similar toPhilips SM250C LED12S-6500 PSU WH or equiv. Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.                                                                 

680

-

-

... More
(ii) Dia 250mm (8.0 mm thick)

201

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia

640

-

-

... More
(d) 40 mm Weight not less than 700 gms

20

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All kinds of soil (For Other than Civil Work)

474

-

-

... More
(i) Supply, installation, testing and commissioning of MS ( IS :226) fabricated pot strainer PN -16, flanged end connection complete with Stainless steel filter screen of 3 mm perforation filter basket, companion flanges, PermanentMagnet, nuts, bolts, gasket, supports, etc. and painting all as specified. As Direction of E/C

-

-

-

... More
Chemical with Anchor rod M12X150-160

4

-

-

... More
VAV-06-GF-D 1851 555

1

-

-

... More
Terminals - 2.7 Sq. mm - 1 Set

-

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
(ii) Pipe size 350 mm diameter, pot size 800 mm diameter and 1190mm, height -1300mm, basket size 895, mm diameter and 678 mm height.

2

-

-

... More
Supply and making terminal joints for the following sizes of 1.1 KV PVC insulated Copper conductor cable including providing tinned lugs, double compression brass cable glands, insulation tape, effecting terminal connections to the equipment complete as required s per directed by Engineeer in Charge.

-

-

-

... More
Supplying, installation, testing & commissioning of 36 watt RGB wallwasher Light, Protection : IP65 Class 1, Input Voltage : 220V AC, Operating Voltage : 24V DC, Power Consumption : 36 watt, Beam Angle : 45 deg, Control Mode : DMX, Housing : Aluminium Alloy, Operating Temp : -20 to 50 deg, 3 pin XLR input/output,

440

-

-

... More
(iii) 200mm dia

12

-

-

... More
Providing and fixing in position glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) For Float glass panes 4 mm thick glass pane (weight not less than 10 kg per sqm)

8

-

-

... More
Constructing Brick masonry manhole in cement mortar 1:4 (1 cement: 4 coarse sand) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90 cm x 80 cm and 45 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg. (wt. of cover 108 kg. And wt. of frame 100 kg.). With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.

50

-

-

... More
Bus Bar

-

-

-

... More
(ii) Star Delta / DOL starter with ON/OFF indicating light, ON/OFF push buttons, control fuses, timers, contractors, overload relay with built-in single phase preventor, control fuses, wiring, interconnections suitable for following rating motor.

-

-

-

... More
Providing and applying white cement based Putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

4601

-

-

... More
(h) 100 mm nominal bore.

8

-

-

... More
Providing and laying rubberised flooring EPDM toping, Density (kg/m3):1000/1200 having specification Hardness (Shore a):68 , Stretch (MPA):2.2 , Abrasion resistance: 0.0075g (ASTM‐D4060‐01) , Rebound resistance: 55% , Friction coefficient: trends μs: 0.995 .trends μk: 0.930 ,Shape deformation: 42% Length (m):10 ±5cm *Width (m):1m ±5mm *Thickness (mm): 15mm ±0.3mm roll type or Tile 500mmx500mmx15mm fixed with polyurethane sealant & corner moulding bead as required complete in all respect.

439

-

-

... More
500 mm dia R.C.C Pipe

342

-

-

... More
7 no. 20A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
3 Sets of 2500/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Carriage for reinforcement Lead upto 5 KM

33878.8

-

-

... More
Bus Bar

-

-

-

... More
Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) as per direction of Engineer in Charge.

-

-

-

... More
(i) AH-LGF-02 12 9350 4

1

-

-

... More
2 nos. 125A 4P MCCB Thermomagnetic controlled.

-

-

-

... More
Analogue input / output module as per requirement.

-

-

-

... More
(i) 40 A TP MCCB - 03 No.

-

-

-

... More
(xxv) AH-2F-02* 37 30200 4

1

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
All ACBs should have Ics=Icu=Icw for 1 sec for the fault level specified in BOQ

-

-

-

... More
VAV-01-2F-A 1275 383

1

-

-

... More
VAV-09-3F-G 3405 1022

1

-

-

... More
Supply, installation, testing & commissioning of 24V 180 AH (2 V x 12 Nos) float cum boost battery charger with SMF battery with cell tester, wooden stand alongwith charger and necessary DC distribution board(Incomer-1nos, Out going- 12nos min.) instrument panel, Ammeter, Voltmeter, interconnections etc. Power supply 240 V, 1 Phase, 50 Hz ± 10% and control cabling to H.T. Panel and L.T. Panels as required for protection relays complete as per specifications and as required as per directed by Engineeer in Charge..

2

-

-

... More
(b) 32 mm nominal bore.

12

-

-

... More
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.

-

-

-

... More
11 no. 63A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Supplying, installation, testing & commissioning of Optical Fiber LIU (OM4, 48Core) as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

124

-

-

... More
(ii) 250 A 4P MCCB - 03 No.

-

-

-

... More
Shuttering for Expansion Joint :-Providing and fixing at all heights and depths 50 MM thick premoulded joint filler board for construction joint having minimum density 95kg./ cum, Non standing with less than 1% water absorption and compression recovery of 93% minimum as per manufactured specification including cost and conveyance of all materials, cutting and placing to the required size, labour charges, sundries, wastage etc. at all levels complete as per drawings and as direction and satisfaction of Engineer-in-charge.

2416

-

-

... More
VAV-03-LGF-F 2550 765

1

-

-

... More
VAV-12-GF-D 2775 818

1

-

-

... More
Supplying, installation, testing & commissioning of CAT6A 24 Port Patch Panel (Unloaded), T568 A/B Wiring for Data as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

378

-

-

... More
Providing priming one coat of approved shade and make over new wooden surface after cleaning removing dirt, scales smoke, grease and sand papering including cost of scaffolding and taxes all complete as per building specication and direction E/I

2321

-

-

... More
Supply, Installation, Testing & Commissioning of Video wall retractable bracket (Make-Standard) as per directed by Engineer in Incharge.

4

-

-

... More
100 mm diameter S.W./PVC pipe

362

-

-

... More
Dry exhaust manifold with hospital exhaust silencer and catalytic converter.

-

-

-

... More
Temporary Floor Protection – After laying of Tiles , granite , marbles etc. :-Supplying of temporary floor protector having thickness 5 mm, comprising of 3 layer (1st Layer HDPE,Sack, 2nd Layer Bonding base Layer & 3rd Layer Expanded polyethylene ) Non stanning with less than 1% water absorption. Cost and conveyance of all materials, sundries, wastage etc as per direction of Engineer in Charge. (Material should be handle with care & reuse. Payment on actual purchase)

75585

-

-

... More
(v) 200 mm dia

39

-

-

... More
Breaker control switch - 3 Sets

-

-

-

... More
Differential Pressure Sensor with transmitter to be installed across chilled water supply & return header - 2 No.

-

-

-

... More
(xix) AH-1F-04 17 15700 4

1

-

-

... More
(ii) 9350 20

1

-

-

... More
Maintenance PC as per directed by Engineer in Charge

2

-

-

... More
Supplying, installation, testing & commissioning of 24 Core Splice tray MM LC (OM4) as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

124

-

-

... More
H2 Sensor

8

-

-

... More
(iv) 40 mm dia

6

-

-

... More
40 mm nominal outer dia .Pipes.

11

-

-

... More
(i) 10445 20

2

-

-

... More
Outgoing

-

-

-

... More
Bus Bar

-

-

-

... More
(ii) 0-500 V Voltmeter with Voltmeter selector switch and control fuses - 1 Set

-

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm

280

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipment's, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 meter & upto 150 meter depth below ground level.All types of soil 300 mm dia Depth

1600

-

-

... More
MMC (Micro memory card) 128KB/ as required - 1 No.

-

-

-

... More
Breaker control switch - 2 Sets

-

-

-

... More
Type of Refrigerant: R134a / Ecofriendly Refrigerant

-

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) (Civil related PHE Items)

142

-

-

... More
(xiv) HRU-3F-02- 2200 CMH Ceiling Suspended

1

-

-

... More
75mm OD Class 6(PN)

170

-

-

... More
6x125 kVAr LT power capacitor banks with 6 No 100 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 No- 3 pin 5/6 A modular socket outlet and 2 No- 5/6 A modular switch, connections etc. as required.

1938

-

-

... More
SLP-03 (SUB LIFT PANEL-03 ) ( THIRD FLOOR - EAST & WEST BLOCK) / SLP-06 (SUB LIFT PANEL-06) ( THIRD FLOOR - EAST & WEST BLOCK) as per direction of Engineer-in-charge.

4

-

-

... More
1 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
EXIT / STAIRCASE SIGNAGE

168

-

-

... More
40mm nominal outer dia. Pipes

112

-

-

... More
(xxxii) AH-2F-08 18 15500 4

1

-

-

... More
Outgoing

-

-

-

... More
800 mm dia. R.C.C. pipe.

210

-

-

... More
(xii) 0-25 A Ammeter with ammeter selector switch & 25/5 CT's - 02 Sets.

-

-

-

... More
Supplying, installation, testing & commissioning of addressable manual call point complete as required.

148

-

-

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete as per directed by Engineer in Charge. . (iii) 160 mm diameter.

2610

-

-

... More
4 Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
3 Sets of 400/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Providing & fixing SS 304 Fire rated Pull handle D Type 19mmx300mm Length 304 ss

160

-

-

... More
Earth links for Door Earthing -

-

-

-

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.

6

-

-

... More
Reverse power relay

-

-

-

... More
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

4

-

-

... More
Power Supply Cable (as per technical specification) as per directed by Engineer in Charge . Note : The bidders shall include the cost of all civil works, foundation works, electrical connectivity,system integration, software programming, system testing, commissioning, mock-up, training to departmental engineers of the operation of all system components and the entire system,. The cost of system integration shall be included proportionally in the rates of items indicated in the bill of quantities. All works and makes shall be carried out as per technical specification and as directed by Engineer in Charge.

100

-

-

... More
(i) 200 mm dia

4

-

-

... More
(d) 32 mm nominal bore.

2060

-

-

... More
Suspended floors, roofs, landings, balconies and access platform

45031

-

-

... More
5x62.5 kVAr LT power capacitor banks with 3 No. 50 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler as per directed by Engineer in Charge.. (iii) 160 mm diameter.

2512

-

-

... More
The flow meter used in the above meter should be based on the ultrasonic principle with no moving parts. The temperature sensors used in the above meter should have a measuring range of 0…130 deg C with a resolution of 0.1 deg C. The BTU meter should have a built in minimum 8 digit LCD display for display of parameters, values and faults.The meter should be compatible with the BMS system ( BACnet) Pressure drop across BTU meter shall not exceed 0.1 bar. Display should be mounted on readable height .

-

-

-

... More
Supply, Installation, Testing & Commissioning of Dual Channel Digital Power amplifier, 2 x 120Watts @ 100V / 4Ω; Bridgeable to 1 X 240Watts @ 100V / 8 Ω; Power Amp Topology : Class D; PSU Technology : SMPS; Convection cooled; Power Supply : SMPS; Output Voltage Taps : 100V - 70V - 50V - 35V - 4Ω; Protection Circuit : Over Current, Over temperature, DC Offset; Frequency response : 50 - 20KHz; S/N ratio : 98 dB A-Wieghted; THD: 0.1% @ 1KHz A Wieghted ; Power Consumption 300W; 1U 19" rackmount as per directed by Engineer in Charge.

1

-

-

... More
3 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Supply a standard tool box containing necessary tools required for operation and maintenance as required as per directed by Engineeer in Charge

2

-

-

... More
Supplying, installing, testing and commissioning of pre-polarized condenser gooseneck microphone with base and on/off switch with logic control, an overall length of minimum 450 mm and with XLR3M-type connector at its base, which shall offer radio frequency interference (RFI) shielding against intermodulation from wireless equipment or devices, cardioid microphone capsule with uniform 120° angle of acceptance (-3dB) or better, frequency response of 50 Hz to 20,000 Hz or better and sound input levels handling capability of minimum 130 dBspl, nominal equivalent noise level of 26 Dba or better and output shall be low impedance balanced (100 ohms) with current consumption shall be 3 mA or better as per directed by Engineer in Charge. .

2

-

-

... More
Bus Bar

-

-

-

... More
(x) 3.0c x 10 sqmm

1200

-

-

... More
3.5 C X 400 sq. mm (82mm)

136

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work,using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All Works above plinth upto Floor V Level

67440

-

-

... More
Heat Rejection of Each tower : 1134000 Kcal/Hr

-

-

-

... More
(vi) AH-LGF-07* 19 15550 6

1

-

-

... More
Incomer

-

-

-

... More
1 no. 200A 4P MCCB, 25 KA Thermomagnetic controlled. with overload, short circuit and earth fault protections.

-

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. (Supply of Butt Hinge paid in separate item)

92

-

-

... More
A set of Sump pumps (Non-clogging type) having discharge capacity of each pump approx.10 cum/hr at 15 m. pumping head (1 working, 1 standby) Suction from sumps in in Lower ground floor, delivery to surface drain at ground level. Including MCC and allied works

4

-

-

... More
DP Switch- Water for Pump Run Status- 9 No.

-

-

-

... More
5 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Waterproofing of Foundation wall/ Concrete Wall (Under Pass) :- Providing and applying water proofing treatment over outside of Retaining wall after properly curing consisting of following works :- 1.Surface Preparation: All RCC wall surfaces to be cleaned properly so that there will be no dust, laitance, oil, grease etc. 2. Application of cover: Providing & Laying 300gsm Geotextile membrane over clean surface properly fixed with lap. 3.Waterproofing Membrane: Providing & Laying 2mm thick PVC membrane having Fire resistance property ( Master seal 700 BG/ Plan WP/ PVC Proofex PGP ) of approved Manufacturer with minimum lapping (Note :- Approved applicator of approved Manufacturer execute the work followed by manufacturer specification, direction with precautionary measure) 4. Application of cover: Providing & Laying 500gsm Geotextile membrane over membrane properly fixed with lap. (Note:- Special Care should be taken for any Damages from Earthwork In filling work)

35122

-

-

... More
1 set of digital type Tri Vector meter.

-

-

-

... More
Supplying, installation, testing & commissioning of 1.1 Kv grade 3C x 2.5 sq mm CU flexible Cable

10000

-

-

... More
25mm dia rebar at 600 mm depth

4

-

-

... More
110 mm dia

12505

-

-

... More
Supplying, installation of Patch Cord Label 2500 Label per Packet as per directed by Engineer in Charge

8

-

-

... More
DDC- 7

2

-

-

... More
4 way,Double door (Power SDB)

404

-

-

... More
All Breakers (ACBs) shall have LCD Display

-

-

-

... More
8 Core x 0.75 Sq.mm Cable

90

-

-

... More
4 C x 16 sq mm A2XFY cable (28mm)

300

-

-

... More
VAV-09-1F-A 935 281

1

-

-

... More
(iii) R,Y,B indication LED light with 2A MCB - 1 Set

-

-

-

... More
Incoming

-

-

-

... More
4 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
Supply, Installation, Testing & Commissioning of Video wall retractable bracket (Make-Standard) as per directed by Engineer in Incharge..

8

-

-

... More
Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable /recoverable separately. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)

109720

-

-

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work

26868

-

-

... More
Supply, installation, testing and balancing of single flap butterfly GI Volume Control Damper in 20 G GI construction, for proper balancing of the air distribution complete as per specifications and as required. As Direction of E/C

-

-

-

... More
VAV-01-1F-B 1855 557

1

-

-

... More
25 MMX 25MM

1000

-

-

... More
4 sets of digital type multi-fuction meter.

-

-

-

... More
Outgoing

-

-

-

... More
DSR ITEMS Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Hard rock (blasting prohibited)

25194

-

-

... More
VAV-04-2F-H 4915 1475

1

-

-

... More
VAV-01-1F-G 2005 602

1

-

-

... More
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.

3528

-

-

... More
2 Nos. 100 Amps TP MCCB,50 KA, Thermomagnetic Protection controlled.

-

-

-

... More
(xii) AH-GF-04 26 23200 4

1

-

-

... More
4 Nos. 125 Amps TP MCCB,50 KA, Thermomagnetic Protection controlled.

-

-

-

... More
MCCBs above 200A ratings should be provided with Copper Spreader Links & Phase barriers

-

-

-

... More
DOOR SHUTTER WOOD PANEL :- Designing ,Providing, fabricate and fixing wood paneling in paneled shutters for doors, (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Paneling for paneled or paneled shutters 20 mm thick : Second class teak wood all complete as per direction of Engineer-in-charge

76

-

-

... More
Supply, Installation, Testing & Commissioning of License Software of Vehicle Monitoring System for gate control, ANPR and Driver image capturing. Storage upto 30 days backup as per technical specification. :- 1no.

-

-

-

... More
Armoured 8 Core x 1 sq mm FRLS Al-Mylar Screened with drain wire, Cable for control cabling as per directed by Engineer in Charge

5000

-

-

... More
VAV-01-1F-E 3670 1101

1

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.

-

-

-

... More
a) 300 mm dia. R.C.C.NP3 pipe

520

-

-

... More
Note: All metering current transformers shall be Class 0.5, 15 VA, cast resin type.

-

-

-

... More
Supply & Providing 25 mm GI Conduit

-

-

-

... More
ACSDB-04 (F) Supply, installation, testing and commissioning of following distribution boards totally enclosed compartmentalized, cubicle floor mounted, indoor type IP:42, factory fabricated with 2 mm thick sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply suitable for 25 KA as per specifications and drawings. All Air Circuit Breakers shall be provided with Micro processor based Earth fault, short circuit and over current releases. Moulded case circuit Breakers shall be microprocessor based electronic trip. Fault level for all ACB/MCCB and bus bar shall be 25 KA, all the motor feeder shall be type-2 coordinated. ICU shall be equal to ICS=100% . As Direction of E/C

2

-

-

... More
VAV-01-LGF-G 1520 456

1

-

-

... More
Differential Air Pressure Transmitter

60

-

-

... More
Supply and apply a polyurethane based elastic, sealant. Including complete installation as per manufacturer’s method statement including cleaning of the joint, repair of the joint edges (if required), backer rod, primer, finishing etc. Primer: ShaliPrime PUM or equivalent , Sealant: ShaliSeal PU GG or equivalent , Expansion joint section: 50 mm(Width)X20(Depth) mm. at the time of finishing work like plastering as directed by Engineer –in-charge as per manufacturer's specification at all heights and depths including necessary backing rod conforming to IS: 1838, all to make the job complete as directed by the Engineer-in-charge complete in all respect.

5532

-

-

... More
7 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
150 mm width x 50 mm depth x 1.6 mm thickness

40

-

-

... More
BELOW DOME :-Designing , Providing & fixing false ceiling semi perforated 12 mm thick micro tegular edged at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling board of Size1220mmx1830 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part-4)-1970 and light reflectance of 85% (minimum) to be laid in horizontal level or Curve linear suspended on inter-locking metal T-Grid of hot dipped galvanised iron design section hanging from structural frame . The work shall be carried out as per specifications, approved shop drawing and as per directions of Engineer-in-Charge.(SUPPORTING M.S. FRAMEWORK & SCAFOLDING PAID IN SEPARATE ITEMS)

500

-

-

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with urinal valve Auto closing system with in built control cock Jaquar cat. no. PRS-CHR-077 or equivalent with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required as per direction of Engineer In Change : One urinal basin with urinal valve Auto closing system with in built control cock.

272.4

-

-

... More
Bus Bar

-

-

-

... More
1 Set "ON /OFF" push button with 2A, 3P MCB, 10KA

-

-

-

... More
c) 5.5 KW - 03 No.

-

-

-

... More
Supplying, fitting and fixing 200 x 20 x 6mm L-type M.S. clamp properly fishtailed, including making holes and setting the Same in 250x125x75mm Cement concrete block (1:2:4) with cost of all labour and materials and taxes as per building specification and direction of the Engineer-in-charge

514

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
(i) 16 A TP MPCB - 08 No.

-

-

-

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of:200 mm dia

32

-

-

... More
Providing and fixing Bell plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I).200 mm dia

64

-

-

... More
2 no. 63A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
1 Set Breaker ON / OFF / TRIP indicating lights with control MCB’s.

-

-

-

... More
2 Sets of 2500 A 4P ACB 65KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings

-

-

-

... More
Supplying, installation, testing & commissioning of 54 watt RGB wallwasher Light, Protection : IP65 Class 1, Input Voltage : 220V AC, Operating Voltage : 24V DC, Power Consumption : 54 watt, Beam Angle : 10 deg, Control Mode : DMX, Housing : Aluminium Alloy, Operating Temp : -20 to 50 deg, 3 pin XLR input/output,

560

-

-

... More
1 no. 320A 4P MCCB, 25 KA microprocessor controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
VAV-03-GF-D 3340 1002

1

-

-

... More
Incoming

-

-

-

... More
Incoming

-

-

-

... More
SITC of Ø 8mm / 50 mm², AlMgSi, semi-rigid Round conductor complied to DIN EN 62561-2 (VDE 0185 Part 202), tesnsile strength 120-280N/MM2 & Environmental test for use as air-termination system,as specified in drawing and confirming to IS/IEC 62305 as per direction of Engineer-in-charge

8000

-

-

... More
Supply, installation, testing and commissioning of Sound Attenuator of outer and inner casing of 0.8mm GI, Insulation 16kg/m³ fiber glass wool covered with Tissue paer with flange on both side as per the given size, specification and as required . The length of sound attenduator is approximate. The final dimensions can be selected based on fans sound data and duct size. As Direction of E/C

-

-

-

... More
VAV-05-1F-H 3585 1076

1

-

-

... More
3.5 C x 120 sq mm A2XFY cable

2063.92

-

-

... More
VAV-03-GF-D 2847 854

1

-

-

2

-

-

... More
DDC- 37

2

-

-

... More
A set of Sump pumps (Non-clogging type) having discharge capacity of each pump approx.60 cum/hr at 15 m. pumping head (1 working, 1 standby) Suction from sumps in Lower ground floor, delivery to surface drain at ground level. Including MCC and allied works

16

-

-

... More
VAV-05-3F-H 1700 510

1

-

-

... More
VAV-01-1F-F 4700 1410

1

-

-

... More
Supply,installation,testing and commissioning of Automatic Air vents. All other parameters as per the technical specifications given in the tender. As Direction of E/C (i) 10 mm dia

113

-

-

... More
VAV-02-1F-D/03-3F-B 3800 1140

2

-

-

... More
(iii) 10 A TP MPCB - 11 No.

-

-

-

... More
4 Strip aluminium bus bar of 63 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
Compressor enclosure: Semi Hermetic

-

-

-

... More
(iv) AH-LGF-06A 5 3950 4

1

-

-

... More
(ii) 110 mm diameter.

244

-

-

... More
Auxiliary contacts required for necessary interlocking of breakers.

-

-

-

... More
Incomer

-

-

-

... More
(b) ON / OFF / TRIP Indicating Lights with control fuses – 1 Set

-

-

-

... More
40 amps

18

-

-

... More
(e) 50 mm nominal bore.

18.64

-

-

... More
(ii) Star Delta / DOL starter with ON/OFF indicating light, ON/OFF push buttons, control fuses, timers, contractors, overload relay with built-in single phase preventor, control fuses, wiring, interconnections suitable for following rating motor.

-

-

-

... More
Pipes, cables etc. exceeding 900 mm dia but not exceeding 1200 mm

532

-

-

... More
(e) 65 mm nominal bore.

16

-

-

... More
Outgoing

-

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 No- 6 pin 15/16 A modular socket outlet and 1 No- 15/16 A modular switch, connections etc. as required.

3366

-

-

... More
Breaker control switch - 1 Set

-

-

-

... More
( e) 50 ltr. Mechanical Foam type Fire Extinguisher filled with AFFF Foam (6%), Applicable fire class A&B, Gross Weight 87 Kg, Empty weight 37 Kg, Can Height 1285mm, Diameter 300 mm, Controllable Discharge mechanism, Discharge Time 40-180 Sec, Jet Range 10 Meters, Average Discharge is 90%, Fitted with EPDM Hose with SS spring of 300mm to avoid kink (3 meter long) & Air aspirated Nozzle, CO2 gas Cartridge of 300 gm. (Confirms to IS 4947), Can Construction : Deep drawn & CO2 Mig welded, External Pure polyester (UV Resistant) and Internal Epoxy polyester powder coated, Brass forged cap, construction as per IS 13386:1992 and ISI Marked.

30.13

-

-

... More
(iii) 7293 20

1

-

-

... More
7 no. 63A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(v) 29700

1

-

-

... More
VAV-04-1F-D 837 251

1

-

-

... More
50 MMX 50MM

1000

-

-

... More
1 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
2 Sets of 100 A 4P MCCBs 50 KA Thermomagnetic based controlled with overload, short circuit and earth fault protections.

-

-

-

... More
(xii) 3.0c x 4 sqmm

1600

-

-

... More
• Electrical Power Cables & control wires- 1 lot

-

-

-

... More
80mm nominal bore

40

-

-

... More
(xxxi) AH-2F-07* 16 13700 4

1

-

-

... More
(iii) R,Y,B indication LED light with 2A MCB - 1 Set

-

-

-

... More
Extra for plaster work over exterior surface for each consecutive floor above first floor including cost of scaffolding etc. all complete as per direction of E/I

638192

-

-

... More
2 core 1.5 mm², PVC insulated, tinned copper conductor cable - shielded.

-

-

-

... More
All ACB shall have Micro processor based release having O/C, S/C, E/F all adjustable and all with adjustable time delay settings and with adjustable Instantaneous protection. All ACB's shall have Ics=Icu=Icw (Short time withstand capacity for 1 Sec. or more)

-

-

-

... More
For 75 mm dia pipe

975

-

-

... More
Size - 800X1200

86

-

-

... More
5 Sets of 1600/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
VAV-01-LGF-C 1260 378

1

-

-

... More
(ii) 110 mm diameter.

172

-

-

... More
Supply, Laying and Termination of CAT-6A UTP Cable, Meets EIA/TIA 568-C.2, UL Listed, length 305mt. Box as per the specifications as directed by Engineer in Charge.

130

-

-

... More
Supply, installation, testing, balancing and commissioning of square powder coated extruded aluminium Supply Plaque air diffusers of various neck sizes with volume control dampers and complete as per specifications. As Direction of E/C

1280

-

-

... More
4. This Schedule shall be fully priced and the extensions and totals duly checked. The rates for all items shall be filled in INK including NIL items.

-

-

-

... More
a) 1.1 KW Motor - 10 No.

-

-

-

... More
(i) 16 A TP MCCB - 13 No.

-

-

-

... More
Partition Drywall System:- Providing and fixing dry wall system 150mm to 175 mm thick with double partition board and infill with 50mm thick glass/rock wool slab/any approved insulation including necessary holding arrangment with minimum 60mm deflection arrangment at ceiling complete in all respect with necessary framing work as follows. ) Wall Box Stud (0.55 mm thick).Channel (0.55 mm thick) of appropriate section of approved make is anchored to the floor & True ceiling with Approved make (Hilti, Fischer, Wurth) Fasteners @600 mm C/C respectively confirming to carry out Pull Out Load-6.8kN. Also channel to be wrapped with Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. partition board of approved characteristics to be fixed with screws of 25mm at minimum spacing of 300mm at centre and 150mm c/c at periphery.Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing compound, (Conforms to ASTM C475) & Paper tape. The junction of the partition with masonry & all penetration through the partition has to be treated with fire and acoustic sealant of approved make all complete as per direction of Engineer in Incharge . (SHOP DRAWING TO BE APPROVED BEFORE EXECUTION OF THE WORK).

-

-

-

... More
LT PANEL-3 (AT SUBSTATION) as per directed by Engineeer in Charge.

2

-

-

... More
END TERMINATION :- Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Breaker control switch - 2 Set

-

-

-

... More
Supplying, installing, testing and commissioning of of ceiling loudspeaker of minimum 4.25 inch driver and a 1 inch tweeter in a 2-way design with polypropylene woofer material and an IP rating of IP50, transformer with multiple taps of at least 30 - 15 - 7.5 - 3.75 watts at 100v and 30 - 15 - 7.5 - 3.75 - 1.75 watts at 70v, frequency response of at least 75 - 20KHz, dynamic power of at least 80 watts and the low impedance connection shall present a load of 16 ohms to the amplifier. The output SPL at 1m 1watt shall be at least 88 dB and maximum output SPL at 1m with full power shall be at least 108 dB. The loudspeaker shall include overload protection for failsafe operation as per directed by Engineer in Charge.

8

-

-

... More
VAV-04-3F-A 4480 1344

1

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 q.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Providing, installing, testing and commissioning of network superwise controll unit (imported UL complied) for connecting all controllers to it and software integration to machine and transfering data to P.C platform. The processer shall be 32 bit, 50 MHZ shall be able to store reports and events logs & shall have a display unit The unit shall support OPEN STANDARD protocol BACnet and Modbus (C) Shall be able to store reports and event logs.(D) WEB ENABLED.The controller shall be capable of connecting the future expansion DDCs / Integrators. It should have at least 3 configurable ports for connecting BACNET/MSTP devices & all these ports should be capable to work as Modbus port. Each port should be able to take at least 60 DDCs in a single loop. It should be capable of storing data at least for 30 hours without any battery in case of power failure & should have micro SD card for backup recovery. It should have capability to connect expansion modules for enhanced flexibility. It should be web enabled and should be able to work with any kind of search engine, it should have wi-fi capability to connect with remote devices.It should be web enabled and should not require any software for controlling/monitoring of hard wired points.

-

-

-

... More
DDC- 17

2

-

-

... More
(i) 75 mm diameter.

4

-

-

... More
CAT – 6 UTP Cable (as per technical specification) as per directed by Engineer in Charge .

100

-

-

... More
(b) 25 mm and weight not less than 500 gms

8

-

-

... More
A set of Sump pumps (Non-clogging type) having discharge capacity of each pump approx.15 cum/hr at 15 m. pumping head (1 working, 1 standby) Suction from sumps in in Lower ground floor, delivery to surface drain at ground level. Including MCC and allied works

2

-

-

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :

-

-

-

... More
Supply, installation, testing and commissioning XYLEM/ KIRLOSKAR / KSB / GRUNDFOSS / WILO / DP make complete factory assembled skid mounted hydropneumatic system comprising of Pump motor set along with control panel to be supplied by the pump manufacturer (located in Pump house for lifting / forcing water from a chamber of U.G. Reservoir to end use point/network as stated below & of required drive (Motor HP), having discharge capacity and pumping head with separate or common base frame all electrical accessories, with over load protection, relay, power cable and control cable from MCC to respective motors, earthling including other accessories (recommended by manufacturer) etc., such as 100 mm dia. pressure gauge (range 0-15 Kg./Sq.cm.) with control cock fitted on delivery line, coupling of required size on suction end flexible removable type (Flanged) coupling on delivery end of pump, required M.S. galvanized supporting frame complete operational as per direction of Engineer in Charge:

-

-

-

... More
10 Sets of R, Y, B Phase indicating lights (LED Type) with 2A, SP MCB, 10KA.

-

-

-

... More
2 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(xi) HRU-2F-04- 1600 CMH Floor Mounted

1

-

-

... More
(i) 250mm dia

6

-

-

... More
Without Insulation on condenser line (ii) 250 mm dia

24

-

-

... More
Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required .

72

-

-

... More
Supply, Installation, Testing & Commissioning of Networkable, Master Access Controller as per the detailed Technical specifications with all accessories complete as required as directed by Engineer in Charge.

10

-

-

... More
4C x 2.5 Sq mm for LCS

320

-

-

... More
315mm diameter

834

-

-

... More
Supply of NON PHOTOLUMICENT Signage Non Autoglow of approved make at any floor at any height,made of Stainless Steel with approved size of Lettering (Hindi & English ), colour,Base Colour & Image with necessary hanging arrangement from celing/ Fixing on wall or Door etc complete in all respect as per direction of Engineer in Charge. Size: 100x300

1899

-

-

... More
Chilled Water Inlet Temperature: 12.22 deg C

-

-

-

... More
Providing & Fixing Glass for Spandrel or Fixed Area of Structural Glazing system/Aluminium Window ST-436 Turquoise of Saint Gobain or Equivalent ( for other make as below)coated toughened blue green shaded glass in DGU (outer:6mm with coating face +12mm air gap+inner 6mm clear) for GRIHA Rating outside Light Transmission of 27% , Solar factor of 0.24 and U-Value of 2.7 W/sq.mtr.K with all fittings fixtures etc. complete as per direction of Engineer in Charge

12471

-

-

... More
Providing and fixing Water level control switch assembly consisting of adjustable low level and high level actuation for auto on / off the respective motor for installing from top / side of the reservoir through sleeve of 150 mm dia on top / side of underground reservoir including flange, PVC guide tube, two numbers floats with SS wire and electric contactor including cost of control wiring from the respective motor panel to the controlling switch etc completer operational. Note:Water level control switch assembly all complete work should be executed by specialized agency. The agency/contractor shall submit of shop drawings for Water level control switch assembly details of construction etc. for approval and according to the approved shop drawing a sample of each of system submitted for preliminary inspection for sample approval. After that the sample should be fixed at site to ascertain its performance. Large scale manufacturing should be taken up only after rectification of defects in sample as directed to the full satisfaction of the department / PMC and after obtaining formal approval of the same. as per direction of Engineer in Charge.

4

-

-

... More
(xi) 3.0c x 6 sqmm

6000

-

-

... More
VAV-07-2F-D/VAV-10-2F-H 2430 729

2

-

-

... More
Size of Lift Well: As mentioned below

-

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
(xxiii) AH-1F-08 16 13700 4

1

-

-

... More
Car Floor Finish: Mirror Polished Granite

-

-

-

... More
4 X 16 sq. mm + 2 X 6 sq. mm earth wire

16188

-

-

... More
Supply, Installation, Testing & Commissioning of 0.6 Mtrs Cable: Crystal-clear video up to 4K DCI (4096 x 2160 @ 30Hz), 4K UHD (3840 x 2160 @ 30Hz), and 1080p @ 60Hz signal HDMI Ethernet Channel functionality: additional dedicated data channel supports networking HDMI (3D, Deep Color, 4K) and HDCP 2.2 compatible Gold-plated connectors for reliable transmissions 0.6 mtrs in Length RoHS-compliant as per directed by Engineer in Incharge.

2

-

-

... More
3.5 C x 25 sq mm A2XFY cable

4142

-

-

... More
VAV-05-1F-H 2690 807

1

-

-

... More
Providing designation 75 A brick work in C.M. ( 1 : 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, scaffolding ,raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.

29264

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Providing and fixing Heavy duty Vitrified Parking Tile (thickness to be specified by manufacturer) of approved make for car moving and others area including with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) with all lead & lift. complete in al rescepect asper drawing and direction of the Engineer-in-charge.

21161

-

-

... More
Alternator :

-

-

-

... More
1 No. power factor digital meter 1 No. APFC relay Dual Source suitable for sequential operation of 13 Capacitor Banks

-

-

-

... More
(i) Dia 400, 2/4 Speed , KW- As per manufacturer MINIMUM THRUST REQUIRED 44/11 N.

14

-

-

... More
Speed Raise/Lower Joysticks - 1 NO -

-

-

-

... More
(d) R, Y, B phase indicating LED light with 2A MCB - 1 set

-

-

-

... More
Size - 600X400

16

-

-

... More
Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329.For 700mm dia Pipe Class K-7 pipes.

24

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
5. No alteration whatsoever is to be made to the text or quantities of this Schedule unless such alteration is authorised in writing by Client / Consultant. Any such alterations, notes or additions shall, unless authorized in writing, be disregarded when tender documents are considered.

-

-

-

... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement 18 mm thick.

1407

-

-

... More
Vapour injection inverter hermetic scroll compressors suitable for operation on R-410A, complete with high/low pressure cut-outs, oil pressure failure switch, fan motor, safety thermostat, over current relay, fusible plugs, fuses, referigerent cooled PCB's etc. and suitable for operation on 380-440V, 3 phase, 50 Hz A.C. supply. The unit shall have a minimum EER 3.28 and IEER 4.36 Upto 40 KW and Minimum EER 3.26 & IEER 4.34 for more than 40 and less than 70 KWr as per ANSI/AHRI standard 1230. All unit shall have auto sequential panel to run the units in cascading mode.

-

-

-

... More
80 mm nominal bore Horizontal

20

-

-

... More
i) Precision Units - 4000 CMH (2W + 1S), 13.9 KW Actual Sensible Cooling at design temperature with matching Outdoor Unit.

6

-

-

... More
VAV-03-3F-F 4730 1419

1

-

-

... More
VAV-09-1F-B 1730 519

1

-

-

... More
Providing and fixing sheet covering over expansion joints with iron screws as per design. Aluminium fluted strips 3.15 mm thick.150 mm wide

4766

-

-

... More
(xxiv) AH-2F-01 18 15000 4

1

-

-

... More
Fast semiconductor fuses for the safety of TSM (3 for each TSM)

-

-

-

... More
Supplying, fitting and fixing Electrical Control Panel Board suitable for outdoor installation of adequate size made out of 2mm thick CRCA M.S. sheet and M.S. flat painted with suitable enamel paint fitted with required electrical accessories of approved make suitable for submersible pump - motor set, described above, including Automatic Star Delta Starter, Main Switch, Single Phase Preventer, Overload Protection Device, Water Level Controller with two probes, one for low level audible warning and one for very low level for tripping of the motor with all required electrical works, Amp. Meter, Volt Meter with Selector Switch, Indicator Lamp, on & off push button, Danger Board etc. as required. ( For (1W+1S) 2 nos of pump.) as per direction of Engineer in Charge.

4

-

-

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.

310

-

-

... More
(c) 32 mm nominal bore.

2

-

-

... More
Enclosure - 1 Set

-

-

-

... More
Supply & Providing 150 mm GI Cable Trays including bends, supports, etc.

-

-

-

... More
Extra for Walls shuttering (any thickness) including attached pilasters, butteresses,plinth and string courses etc. at any Level Above Lower Ground Floor Level as per Drawing, complete in all respect as per direction of the Engineer in charge.

24064

-

-

... More
(xii) AH-GF-03 20 14150 6

1

-

-

... More
(vii) Star Delta / DOL starter with ON/OFF indicating light, ON/OFF push buttons, control fuses, timers, contractors, overload relay with built-in single phase preventor, control fuses, wiring, interconnections suitable for following rating motor.

-

-

-

... More
50 MMX 50MM

2500

-

-

... More
VAV-01-2F-H 2930 879

1

-

-

... More
Providing & fixing SS 304 material, SS finish 450mm long Tower Bolt of approved make & design for Flush Wooden Door Shutter complete in all respect as per direction of Engineer in Charge.

829

-

-

... More
(i) 450 A, 415V, 3ph, 4 wire Aluminium busbar

-

-

-

... More
8 Sets of R, Y, B Phase indicating lights (LED Type) with 2A, SP MCB, 10KA.

-

-

-

... More
1 Set of 1600/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
DDC- 45

2

-

-

... More
PRESSURIZATION FANS:- Supply, installation, testing and commissioning of tube axial fan with adjustable pitched aluminium alloy impeller, TEFC squirrel cage induction IE2 motor with class 'F' insulation motor,1400 RPM direct drive arrangement, GSS/MS sheet metal casing, and other accessories as required and as per specification of following capacities as per Schedule of Equipment. As Direction of E/C

-

-

-

... More
Car Wall Finish: STAINLESS STEEL (1.5MM) 23003 SILVER ST4 CAR HANDLE 3 SIDES/ BRASS FINISH ONLY FOR VIP LIFT (As per approved design & Model)

-

-

-

... More
DDC- 10

2

-

-

... More
Supply, Installation, Testing & Commissioning of HDMI, DP Cable connectors ( Make: Standard) as per directed by Engineer in Incharge..

2

-

-

... More
Supplying and installing following size of perforated painted with powder coating MS cable trays Tee with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
VAV-02-2F-E 2865 860

1

-

-

... More
All ACBs should have Ics=Icu=Icw for 1 sec for the fault level specified in BOQ

-

-

-

... More
VAV-04-3F-G 3950 1185

1

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

-

-

-

... More
NORMAL INLINE EXHAUST FAN Supply, installation, testing and commissioning, of duct mounted Inline fans complete with direct/belt driven centrifugal fan, TEFC squirrel cage induction motor, heavy gauge sheet metal casing, rubber isolator mounts, concrete foundation/ hanging arrangement and other accessories, complete as required and as per specification. fan shall be AMCA certified for sound and performance. Inline fans shall be of following capacities: As Direction of E/C

-

-

-

... More
(a) 63 A 4P MCCB – 1 No.

-

-

-

... More
24 Core x 2.5 Sq.mm Cable

300

-

-

... More
VAV-07-3F-F 2890 867

1

-

-

... More
Engine Start PB Green - Test Push Button with 2 NO Contact - 1 No.

-

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

14600

-

-

... More
Supply, installation, testing and commissioning of factory built, cabinet type, horizontal, floor mounted/CS Direct/Belt driven air handling units in double skin construction of following capacity at required static pressure complete with factory fabricated independent sections, housing the various components e.g. blower/plug fan, IE 2 motor suitable for operation on 415 ± 10% volts, suitable for VFD operation 3 phase, 50 Hz AC supply, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% in the supply of AHU, fire retarding canvass connection with volume control dampers, mixing chamber, copper tube, aluminium finned chilled water cooling coil,thermostat and control wiring, Thermowell for installing the BTU meter in the required AHUs at Inlet & Outlet piping, pre filters sets, drain connections , 150 mm SS Dial type Temperature Gauge glycerine filled 0-50 deg C range with SS stem & all other mounting accessories, SS thermowell of Greystone Make or equivalent., 150 mm SS Dial type pressure gauges glycerine filled, range 0-8 bar with Ball Valve, syphon tube, complete. All other parameters as per the technical specifications given in the tender. Concrete foundation with anti-vibration mountings etc. as required and as per "Schedule of equipment" and specifications. As Direction of E/C

-

-

-

... More
VAV-11-GF-D 3162 949

1

-

-

... More
3. Electrostatic precipitator section - Electrostatic section shall be made of 16 Gauge galvanised sheet, high bake epoxy powder coated, SS spiked ionizers to create high voltage DC field, aluminium collector plates, which should be alternatively charged postive and negativce with large collecting area with deep cell, to work as magnet for charged smoke and oil particles. Average efficiency of 90-95% in single pass as per ASHRAE/ DOP test method. Electrostatic precipitator should be able to charge particles from 0.01 micron to 10 microns through solid state power supply. Collector cell should be of permanent type and incorporate slide out facility for easy removal for cleaning. Power supplies shall be 100% solid state.

-

-

-

... More
VAV-03-3F-G 2080 624

1

-

-

... More
3mm thick ply board

10990

-

-

... More
Cooling tower outlet temperature: 32.2 °C

-

-

-

... More
a) 100 mm dia

16

-

-

... More
Under Voltage & Over Voltage protection with protection release.

-

-

-

... More
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l.

10128

-

-

... More
(e) 50 mm nominal bore.

2

-

-

... More
(ix) 3.0c x 16 sqmm

1000

-

-

... More
VAV-11-3F-C 3825 1148

1

-

-

... More
Supplying, installing, testing and commissioning of 12VDC charger module for simultaneously charging up to ten Lithium-Ion battery packs, status display with 10 LEDs for monitoring the overall charging process and a test button for checking the charge status of an individual battery pack, maximum power consumption of 250W, approximately 4 hours charging time for full charge. Same OEM as conference system as per directed by Engineer in Charge.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Intelligent Single Door Expander Unit as per the detailed Technical specifications as directed by Engineer in Charge

38

-

-

... More
d. Liabilities, obligations and risks arising out of Conditions of Contract.

-

-

-

... More
8. The unit rate for all local equipment or materials in Indian Rupees shall include cost of equipment and materials including all taxes and duties and also including forwarding, freight, insurance and transport into Contractor’s store at site, storage, installation, testing, balancing, commissioning and other works required.

-

-

-

... More
CB Trip PB Red - Test Push Button with 2 NO Contact - 1 No.

-

-

-

... More
Supply, Installation, Testing & Commissioning of digital audio network server that shall be implemented on a RJ-45 connector and shall support Ethernet connection for programming and control on a RJ-45 connector. The server shall have internal DSP processing. The server shall include 4 channels of General Purpose Input and Output connection (GPIO) for sending or receiving logic signals. The programming of the GPIO ports shall be software configurable. The server shall include a RS-232 connection for control data transmission and such operation shall be software programmable. The server shall include a Universal Serial Bus (USB) connection on a standard USB-B type connector. The server shall be software configurable to stream up to 8 channels of digital USB Audio Class 1 transmission either into or out of the server or simultaneous input and output. The server shall provide 12 balanced input connections for receiving of microphone or line level analog audio signals on screw-down, removable connectors. The input connections shall include Acoustic Echo Cancellation (AEC) hardware and firmware, the parameters, routing and operation of which shall be software programmable. The server shall provide 8 balanced output channels for the transmission of microphone or line level analog audio signals on screw-down, removable connectors. Each individual channel shall have its own dedicated connection. The server shall provide front panel OLED identification of server power, status, alarm, and activity as well as system-wide alarm. The server shall be rack mountable (1RU) and feature software-configurable signal processing, including but not limited to: signal routing and mixing, equalization, filtering, dynamics, and delay, as well as control, monitoring, and diagnostic tools. The server shall be CE marked, UL listed and shall be compliant with the RoHS directive as per directed by Engineer in Charge.

1

-

-

... More
VAV-04-LGF-C 3230 969

1

-

-

... More
Supply, installation, testing and commissioning of Acoustic Enclosure suitable for 2250 KVA, 415 V Radiator cooled DG s per directed by Engineeer in Charge.

6

-

-

... More
Bus Bar

-

-

-

... More
(i) 16 A TP MPCB - 11 No.

-

-

-

... More
2 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
1 no. 320A 4P MCCB, 25 KA microprocessor controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Incoming

-

-

-

... More
Supply, Installation, Testing & Commissioning of Dual Channel Digital Power amplifier, 2 x 120Watts @ 100V / 4Ω; Bridgeable to 1 X 240Watts @ 100V / 8 Ω; Power Amp Topology : Class D; PSU Technology : SMPS; Convection cooled; Power Supply : SMPS; Output Voltage Taps : 100V - 70V - 50V - 35V - 4Ω; Protection Circuit : Over Current, Over temperature, DC Offset; Frequency response : 50 - 20KHz; S/N ratio : 98 dB A-Wieghted; THD: 0.1% @ 1KHz A Wieghted ; Power Consumption 300W; 1U 19" rackmount as per directed by Engineer in Charge.

1

-

-

... More
6 no. 20A DP MCCB, 25 KA Thermomagnetic controlled.

-

-

-

... More
VAV-05-2F-F 3035 911

1

-

-

... More
Providing & Fixing Aldrop Brass material & Brass antique finish 450mm Longx16mm dia for Panelled Door Shutter with necessary screw etc. complete in all respect as per direction of Engineer-in-charge.

64

-

-

... More
NPLV- Minimum 9.3

-

-

-

... More
Extra for using chemical for artificial treatment of soil with 20 Kgs for each earth pit as required (TERREC/TERRA GEL or equivalent). The remaining space of earth pit shall be filled with agricultural soil and properly compacted as per directed by Engineer in Charge.

30

-

-

... More
LIFT WELL PRESSURIZATION (i) 6290 CMH at SP at 20 mm WG

4

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
Supplying, fitting and fixing C.P on brass Central hole basin mixer without popup waste system without 450 mm long braided hoses, {Jaquar, Clarion (Quarter Turn), Cat. No. CQT - CHR - 23167B or approved equivalent}as per direction of Engineer in Charge.

31

-

-

... More
Supplying and fixing of Industrial Type 63A - 3Pin Nutral & Earth Metal Plug and Socket as directed by Engineer in Charge

6

-

-

... More
Linear pneumatic heat Detection Tube with all necessary fittings & supports. as per direction of Engineer in Charge.

3456

-

-

... More
1 no. 20A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(iv) 22.2 mm

11

-

-

... More
CO Sensor

32

-

-

... More
** - AHUs are with Pre & Carbon Filter

-

-

-

... More
(xxxv) AH-3F-06* 28 24150 4

1

-

-

... More
3 Line Display Multifunction Meter - 1 No.

-

-

-

... More
(x) AH-GF-01 26 22500 4

1

-

-

... More
400 amps 35KA SC for 1 sec

32

-

-

... More
1 Set of 160/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
SWITCHES/SELECTORS/PB

-

-

-

... More
Extra for using chemical for artificial treatment of soil with 20 Kgs for each earth pit as required (TERREC/TERRA GEL). The remaining space of earth pit shall be filled with agricultural soil and properly compacted as per directed by Engineeer in Charge.

40

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
VAV-02-1F-F 4180 1254

1

-

-

... More
2 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Synchronous alternator at 2250 KVA, 415 Volts at 1500 RPM , 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brush less, continuous duty, self-excited and self-regulated through AVR confirming to IS:4722 / BS 2613 suitable for tropical conditions and with class H insulation.

-

-

-

... More
The noise level of the unit shall be ≤ 85 db at 1 m distance from the source in any direction

-

-

-

... More
Custom clearance, inland transport up to site, lifting, shifting & installation on Ground Floor Level at Service Block

-

-

-

... More
Design, Fabricate ,Supplying & Fixing of PHOTOLUMICENT Signage Autoglow of approved make at any floor at any height, made of Rigid sheet,ARS 10000,1mm Thk, with approved Size of Lettering (Hindi & English ), Colour, Base Colour & Image with necessary hanging arrangement from celing/ Fixing on wall or Door etc complete in all respect as per direction of Engineer in Charge.

-

-

-

... More
Providing and fixing in position glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) For 6mm clear/frosted Toughened

822

-

-

... More
Supply, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. (Above False Ceiling areas).

752

-

-

... More
Bus Bar

-

-

-

... More
Outgoing

-

-

-

... More
Top roof should be well ventilated, especially with ventilation provided on the vertical side of the roof to enhance the hot air outflow while in operation. Roof should also have provision to mount atleast 4 nos. of 90 CFM cooling fan trays and there should be space for the cable entry from the top. Thickness of powder coating should be 60 microns or more. Colour of the cabinet should be Black The structure and all its components should be made from CRCA Steel Material – at least 1.2mm thick The rack should be provided with 1 Heavy Duty Shelf of 390 mm Depth. Vertical power distribution units provided should have 6 outlets of 5/15 amp capacity. All cables used should be of ISI grade with 2.5sq mm cross sectional area. All the connecting ends must be tinned so as to avoid any loose wire strands. Rack should have the appropriate mounting provision for the multiple of these PDUs at the rear of the rack. Each Rack should be provided with one numbers of such power distribution units. Certifications: RoHS

-

-

-

... More
(i) 100 mm nominal bore.

9658

-

-

... More
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :

-

-

-

... More
Fan shall be installed in vertical position, hence bearing shall be design in a way to take over the vertical load of motor and other accessories. Installation arrangement for fans in vertical position, with anti vibration mountings , rectangular hollow pipes/ channels to take the static and dynamic load. Vibration isolator shall be selected/ designed in such a way that fan vibrarion should not transfer to the structural members . Power cables from panel to fans motor etc as required upto complete satisfaction of client/ Engineer incharge.

-

-

-

... More
6/32,amps, DP

408

-

-

... More
(vii) TFA-LGF-01 15 4850 8

1

-

-

... More
VAV-09-2F-H 3710 1113

1

-

-

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design.(a) With 20x20 mm square bar.

7500

-

-

... More
Supplying and fixing following way, three pole and neutral, sheet, MCB distribution board, 415 volts on surface/recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (For LDB,PDB,CDB & Servie Block) 8 Way (4 + 24), Double door, Horizontal type (MCB Distribution Boards )

28

-

-

... More
Supply, Installation, Testing and Commissioning of LED Bulkhead with a nominal system lumen output of 600 lumens and a minimum system efficacy of 60 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 5700k or 6500K and CRI 70. The luminaire shall meet IP65 rating with THD 20% and PF 0.9. The luminaire housing should made of High pressure die cast Aluminium with polycarbonate front diffuser. The total Power Consumption should be within 8W to 14W (including driver). Similar to Philips Make ENDURALED BULKHEAD "WT202W LED6S CW PSU S1 PC" or equiv. Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

480

-

-

... More
Motor control centre for fuel pumps panel as described above.

-

-

-

... More
VAV-07-GF-E 3374 1012

1

-

-

... More
Providing designation 75A brick work in C.M (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M 2 to to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I

200

-

-

... More
100 KWp, 3phase on grid rooftop solar pv power plant : Design, supply, installation, testing & commissioning of 100KWp (2x 50KWp) on grid Type Roof Top Solar Power plant including Solar Photo voltaic Modules, Power Conditioning Units with built-in MPPT algorithm,AJB (Array Junction Box), along with Solar Module Mounting Structures,Data Logger & Remote Monitoring System, AC & DC Junction Boxes, DC & AC Cables and other Accessories. As per technical specification & BOQ. Solar Modules - 50 kwp x 2 = 100 kwp. 335 Wp each - (150x2)= 300 Nos. Power Conditioning Unit (PCU) - (50 kw x2)=100 kw. 50 kW on grid Inverter 2 nos. Module Mounting Structure - 1 Lot . AJB (Array Junction Box) -As per panel designer nos,Remote Monitoring System - 2 nos, DCDB (DC Distribution Box) with all protection Equipment 2Nos. ACDB (AC Distribution Box) with all protection Equipment 2 Nos. AC- Bus Bar - 1 Lot . Earthing 20 Nos/or as required as per site as per direction of Engineer-in-charge.. DC Cables - 1 Lot AC Cables - 1 Lot DC Cable 4 Sq. -6 Sq.- Cu - 1 Lot AC Cable- 10 Sq., 35 Sq.mm-Cu,50 Sq. mm -Cu & 70 Sq.mm and higher - 1 Lot other Electrical Accessories - 1 Lot

2

-

-

... More
VAV-05-2F-H 1490 447

1

-

-

... More
Outgoing

-

-

-

... More
Fabrication, Supply, installation, testing & commissioning of cubicle type compartmentalized, floor mounted, LT capacitor panel of suitable size made out of not less than 2 mm thick MS sheet, dust and vermin proof and comprising of following panel mounting switchgears there in as per CPWD specifications (part IV) i/c suitable capacity 3 strip aluminium bus bar, compatible to SCADA / BMS system with spare contacts, connection inter-connection etc. as required.

-

-

-

... More
(iv) 10 A TP MPCB - 08 No.

-

-

-

... More
Providing and fixing a keyboard at a proper place containing castle keys and all other keys as required as per directed by Engineeer in Charge

2

-

-

... More
Providing and fixing mosquito proof overflow brass coupling of approved design all complete as per direction of Engineer-in-charge .

-

-

-

... More
Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :

-

-

-

... More
Outgoing

-

-

-

... More
(xvii) AH-1F-02* 42 38600 4

1

-

-

... More
For 150mm dia Pipe

978

-

-

... More
Supplying, fitting and fixing M.S. Housing Clamp of approved quality to suit size of Housing pipe upto 300 mm dia. Including necessary Nuts, Bolts and Washers as per direction of Engineer-in-charge:

24

-

-

... More
3 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Providing 25 mm. thick damp proof course with cement concrete M-150 with nominal mix of ( 1 :2 : 4 ) with approved quality of stone chips of 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, and mixing cement concrete in mixer with 5% cico or any other approved water proofing compound and placing in position, striking, curing, taxes and royalty all complete: as per building specification and direction of the Engineer-in-charge

556

-

-

... More
Bus Bar

-

-

-

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required. (For Water works - service building-1 to start fire fighting pumps through electrical control panel).

22

-

-

... More
Supplying, fitting and fixing Sanitary fixtures and fittings for Paraplegic Toilet set consisting of Starwhite Wash basin of size 460 mm x 360 mm with one pair of mounting brackets, Starwhite European water closet and Cistern complete with fittings and Seat cover, one no. of Hinged rail 760 mm, five nos of Grab rails 600 mm as per direction of Engineer In Change.. (Hindware Cat No. 70002, Model - Matrix Set or approved equivalent). a) 6 mm thick plain glass Beveled edge mirror of approx. Size 450 mm x 300 mm including C.P. brass revolving fittings 3 mm plywood board and C.P. hinges etc. b) C.P. on brass Toilet paper holder. c) C.P. brass Soap dish container. d)C.P. on brass Towel ring round. e)C.P. on brass Angular stop cock with wall flange. f)C.P over brass Bottle trap with internal partition of 32 mm size with 250 mm and 190 mm long wall connection pipes and wall flange, Jaquar Cat. No. 769L or approved equivalent. g)C.P.on brass Hand Shower (Health Faucet) (ABS Body) with 1 metre long PVC tube and Wall Hook, Jaquar Cat.No. ALD - IVY - 583 or approved equivalent. h)C.P.on brass Two way bib bock with wall flange, Jaquar Cat. No. SOL - 6041 or approved equivalent. i)C.P.on brass Pillar cock with wall flange Jaquar Cat. No. 15001.32 mm dia j)CP brass waste coupling k)32 mm dia CP brass waste coupling

72

-

-

... More
3 Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Breaker control switch - 2 Sets

-

-

-

... More
1 nos. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
speaker cable Four pair, 2-core, 1.5 sqmm

30564

-

-

... More
f. In the event of conflict between Schedule of Quantities and other documents including the Specifications, the most stringent shall apply. The interpretation of the Engineer incharge shall be final and binding.

-

-

-

... More
Chemical with Anchor rod M8X110

4

-

-

... More
Chemical with Anchor rod M10X125-130

4

-

-

... More
DDC- 9

2

-

-

... More
Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 as per direction of Engineer in Charge.

-

-

-

... More
3.5C x 50 Sqmm

4

-

-

... More
Incoming

-

-

-

... More
(v) Dia 100mm

457

-

-

... More
Providing and fixing Carpet flooring using Carpet Tile of approved make, shade and pattern and of the following specification: Pile fibre composition BCF Polymide 6.6,Total thickness 8.0mm,Effective pile thickness 5.0mm, Total mass 4550g/m² of size 500 mm x 500 mm with Primary backing Polyester fleece and Secondary Backing Desso Ecobase containing at least 75% C2C positively defined recycled content including necessary green quality adhesive , Labour & tools etc. complete in all respect as per direction of the Engineer in charge. (Note:- Special agency will be deployed after approval of the Engineer in charge & warranty maintenance period will be applicable as per detailed specification will be followed.)

784

-

-

... More
Cast steel ball valves 80mm dia

10

-

-

... More
(i) 100 mm width X 50 mm depth X 1.6 mm thickness

400

-

-

... More
(v) AH-LGF-06** 8 7500 4

1

-

-

... More
(a) 300 A 4P MCCB – 1 No.

-

-

-

... More
(iii) 300 mm dia

571

-

-

... More
5 no. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
VAV-03-1F-D 3400 1020

1

-

-

... More
(xv) AH-GF-06 18 12750 4

1

-

-

... More
Extra for depths beyond 60 cm of sand cast iron drop connection complete: 100 mm dia sand cast iron drop connection

3

-

-

... More
2500 A, 415V, 3 strip, 50 KA, 50 Hz Aluminium Bus bar

-

-

-

... More
Constructing Brick masonry manhole in cement mortar 1:4 (1 cement: 4 coarse sand) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design.(b) Inside size 120 cm x 90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg. (wt. of cover 108 kg. And wt. of frame 100 kg.). With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.

550

-

-

... More
Auxiliary contacts required for necessary interlocking of breakers.

-

-

-

... More
EXIT SIGNAGE (Right)

38

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
A set of Sump pumps (Non-clogging type) having discharge capacity of each pump approx.10 cum/hr at 15 m. pumping head (2 working, 1 standby) Suction from sumps in in Lower ground floor, delivery to surface drain at ground level. Including MCC and allied works

16

-

-

... More
300 mm dia NB pipe 4.85 mm thick plate

72

-

-

... More
(i) 1.0 TR

64

-

-

... More
(viii) Star Delta / DOL starter with ON/OFF indicating light, ON/OFF push buttons, control fuses, timers, contractors, overload relay with built-in single phase preventor, control fuses, wiring, interconnections suitable for following rating motor.

-

-

-

... More
(ii) 200mm dia

12

-

-

... More
Chiller Power Input : ≤ 0.65 KW/TR

-

-

-

... More
1 Set of 200/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Providing and fixing Water Level Monitor (Water Gauge) for installing on the side wall of Water Reservoir consisting of calibrated back ground board, copper float, strand red wire, required number of pulleys, puddle collar / sleeves as required adjustable pointer etc. complete operational as per direction of Engineer-in-charge.(Water level difference upto 4 m.) - For over head reservoir

12

-

-

... More
VAV-10-3F-C 2930 879

1

-

-

... More
VAV-04-1F-A 1510 453

1

-

-

... More
(b) 20 mm nominal bore.

56

-

-

... More
2 no. 32A DP MCCB, 25 KA Thermomagnetic controlled.

-

-

-

... More
DG Synchronization Panel for Substation

2

-

-

... More
Note: All metering current transformers shall be Class 0.5, 05 VA, cast resin type.

-

-

-

... More
(iii) 40 A 4P MCCB - 03 No.

-

-

-

... More
300 mm width x 50 mm depth x 1.6 mm thickness

28

-

-

... More
4 Sets of 16 amps TP M.C.B'S.

-

-

-

... More
c) 5.5 KW - 01 No.

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
40mm dia

7000

-

-

... More
(xii) HRU-2F-06- 2700 CMH Ceiling Suspended

1

-

-

... More
PMDB-GF (POWER MAIN DISTRIBUTION BOARD) ( GROUND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 1 as per direction of Engineer-in-charge

2

-

-

... More
With Insulation (i) 200 mm dia

36

-

-

... More
50mm dia

4000

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Video Extender It should Extends the distance between HDMI source and HDMI display It should Implements HD Base T - Lite extension technology using only one Cat 5 cable to connect the transmitter and receiver. It should be HDMI (3D, Deep Color, 4kx2k); HDCP Compatible. It should support Long distance transmission - up to 70m. It should Supports resolutions of up to Ultra HD 4kx2k and 1080p Full HD. It should selects the optimum EDID settings for smooth power-up and highest quality display. It should Supports up to 340MHz bandwidth for high performance video. It should Supports Dolby True HD and DTS HD Master Audio. It should have Max. Data Rate 10.2 Gbps (3.4 Gbps Per Lane). It should support Max. Resolutions / Distance Up to Up to 4K@35m (Cat 5e/6) / 40m (Cat 6a/Cat6); 1080p@60m (Cat 5e/6) / 70m (Cat 6a/ Cat6). It should support Operating Temperature 0 - 50°C. It should have support Temperature -20 - 60°C.It should have support 0 - 80% RH, Non-Condensing as per directed by Engineer in Incharge.

6

-

-

... More
Supply, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required.

10

-

-

... More
Waterproofing of Underground Reservoir(Potable water)/(Service Water): Providing and laying water proofing treatment on Underground Reservoir for potable water consisting of following :-(Measurement on treated area Floor & wall separately and Rate is inclusive all items) 1.Surface Preparation: All surfaces to receive the waterproofing to be mechanically cleaned properly so that there will be no dust, laitance, oil, grease etc. 2.Coving:Coving to be done at all junctions by cutting V grooves of 20 mm x 20 mm and filling by cement-sand (1:4) mortar admixed with (Sika Top 122HS/Nitobond SBR Latex/Master Emaco SBR 2) of approved manufacturer with their direction. 3.Bore Packing: Bore packing to be done at all pipe entries with suitable material(Sika Rep Microcrete 4 /Fosroc Cebex 100 /BASF Master Emaco S 340) food grade certified of approved manufacturer with their direction. 4.Water proofing product:-Supply and application of a non shrink, expanding grout admixture with suitable food grade certified material (Sika Intraplast EP/ FOSROC CEBEX 100/ BASF Master Flow 150 ) of approved manufacturer with their direction, by pressure grouting inside RCC floor & wall after 28 days of curing using 12mm dia, 75 mm long GI nozzles 1.5 m C/C in the concrete.Next Supply and application of an water proofing inside RCC floor & wall upto plinth appropriate coating of minimum thickness 2mm(Sika Topseal 107/ FOSROC CM 210/ BASF Master Seal 550)of approved manufacturer with their direction. 5.Covering with Screed plastering:-After curing Providing and applying 12mm thick plastering with Cement Mortar 1:4 admixed with integral waterproofing admixture (Sika Plastocrete Plus/Fosroc Conplast WL/BASF Master PEL 777)of approved manufacturer with their direction. 6. Finishing:-Finishing with Neat cement punning over plastering work.

26676

-

-

... More
Supplying, installing, testing and commissioning of HDMI, DP Cable connectors ( Make: Standard) as per directed by Engineer in Charge

1

-

-

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

68

-

-

... More
VAV-08-2F-F 1705 512

1

-

-

... More
32mm nominal bore

238

-

-

... More
(iv) 25 A TP MPCB - 02 No.

-

-

-

... More
Providing and fixing 32 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required. as required. as per direction of Engineer-in-charge.

1606

-

-

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :

-

-

-

... More
Supply, installation, testing and commissioning of Direct expansion Concealed / Hi wall type indoor units with copper tube aluminium finned direct expansion cooling coil, pre filters, electronic expansion valve with corded remote and control wiring, drain connections, drain pump and sequential panel, drain piping as per drwings, Additional charge of refrigerant, mounting structure as per manufacturer recommendation, with anti-vibration mountings etc., as required and as per schedule of equipment and specifications. As Direction of E/C

-

-

-

... More
(iv) 100mm dia

9

-

-

... More
Providing necessary discharge rod for 11 kV as per directed by Engineeer in Charge

2

-

-

... More
Providing & laying, in trenches or in exposed, of uPVC pipes with fittings of class III (6 kg/ cm2) as per IS:4985 and as per specification with rubber ring and rubber lubricant,(EPDM/SBR) for all depths with or without well graded granular bedding (Type-E) for pipe length as per drawing and specification including hydraulic field testing and commissioning etc all complete as directed by Engineer.

-

-

-

... More
3200 A, 415V, 3 strip, 50 KA, 50 Hz Aluminium Bus bar

-

-

-

... More
300 A, 415V, 4 strip, 50 KA, 50 Hz Aluminium Bus bar

-

-

-

... More
Supply and installation of LT Power Cable as per directed by Engineer in Charge

-

-

-

... More
Supplying & fixing Hydraulic Door Closure weight upto 80kg with adjustable arm for Aluminium Door Shutter with necessary screw etc. complete in all respect and instructions of the Engineer in charge.

205

-

-

... More
Lot, thermal insulation on the pump with same material & thickness as the connected pipe

-

-

-

... More
VAV-07-1F-H 2110 633

1

-

-

... More
Supply, Installation, Testing & Commissioning of 1000 Base LX SFP Module completely as per specifications as directed by Engineer in Charge.

216

-

-

... More
Outgoing

-

-

-

... More
Fan should be AMCA certified for air and sound performance.

-

-

-

... More
(xii) 0-6 A Ammeter with ammeter selector switch & 6/5 CT's - 05 Sets.

-

-

-

... More
VAV-05-1F-A/03-2F-A 1720 516

2

-

-

... More
63 amps

18

-

-

... More
Providing, laying and fixing 80mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required

200

-

-

... More
Providing & Laying Stone guard coating as per approved make over Red Sand Stone after necessary preparation of surface at any level complete in all respect as per direction of Engineer-in-charge & specification of the manufacturer.

31170

-

-

... More
LT PANEL-2 (AT SUBSTATION) as per directed by Engineeer in Charge.

2

-

-

... More
Clips for Joints

200

-

-

... More
FIRE DETECTION SYSTEM 1. Fire alarm systems and emergency communications systems installation, fixing, testing and commissioning shall be as per IS 2189, NFPA 72 (latest edition) , FM approved and local & state codes. 2. The Main Fire Panel shall be located in the Fire control room (Ground Fl. as per drawing) and shall be suitable for interfacing (through soft integration) with BMS system. The fire alarm system detectors, manual call points, hooters, speakers wiring and the integration & testing of above fire alarm components with Fire Panels in Secretariats (EAST & WEST BLOCK, Services building 1 & 2, under ground parking is included in present scope of work. Quantity may vary as per site conditions. 3. All special fixtures, equipments, accessories, control devices, attachment etc. not specifically mentioned but are required for safety & proper functioning and efficiency of system shall be included in the offer. 4. Power Supply - A source of electrical operating power (UPS, including the circuits and terminals connecting it to the dependent system components are in the scope of bidder. 5. The bidders shall include the cost of system integration, software programming, system testing, commissioning, training to departmental engineers, hands-on demonstrations of the operation of all system components and the entire system, documentation (the systems manufacturer's representatives shall provide a typewritten "sequence of operation" to the owner) etc. as per technicial specifications shall be included in the offer. The cost of system integration shall be included proportionally in the rates of items indicated in the bill of quantities as per directed by Engineer in Charge.

-

-

-

... More
(d) 40 mm and weight not less than 1.0 kg

20

-

-

... More
Size - 500X200

433

-

-

... More
(iii) 26010 CMH at SP at 20 mm WG

2

-

-

... More
Duty parameters (each pump)

-

-

-

... More
(iv) 595 +510 10

22

-

-

... More
Outgoing

-

-

-

... More
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.

30564

-

-

... More
100 mm width x 50 mm depth x 1.6 mm thickness

10

-

-

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire [Lift Shaft Power Points]

1550

-

-

... More
8 Sets of 40A 4P MCBs, 10KA

-

-

-

... More
Bus Bar

-

-

-

... More
Unit mounted VSD panel with passive harmonic filter. Power and control cabling from panel up to motor shall be included.

-

-

-

... More
Auto Synchronization Panel Supply, installation, testing and commissioning of auto main failure (AMF) / auto synchronizing / auto load sharing / auto load management based on demand feed back, Genset controller with load management PLC shall collect demand feed back from MFM in panels / transformer incomers & necessary wiring & communication from meter to PLC, auto change over, inter locking DG control and operation programmable logic controller (PLC) based logic panel cubicle type made of 2 mm thick CRCA sheet enclosure, powder coated, free standing, floor mounted, dust and vermin proof, indoor suitable for following DG sets complete with all measuring instruments, protective devices, alarm, etc. as required for above functions rated for 65 KA RMS fault level withstand for 1 sec, PLC with required digital & analogue input & output modules, input/output racks, power supplies and communication with Power Monitor as per directed by Engineer in Charge.

-

-

-

... More
Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.” Note : Excess/less cement used than specified in this item is payable/ recoverable separately.All works above plinth and upto floor V level :M-15 grade plain cement concrete. (cement content considered @ 240 kg. /cum) (For Levelling course)

4296

-

-

... More
3. All equipments, quantities and technical data indicated in this Schedule are for the Contractor’s guidance only. This schedule must be read in conjunction with other documents. The Contractor shall be paid for the actual quantity of work executed by him in accordance with the approved Shop Drawings at the contract rates.

-

-

-

... More
Supplying, fitting and fixing C.P on brass Double coat hooks, Jaquar Cat. No. ACN - CHR - 1161N or approved equivalent.

699

-

-

... More
(viii) 1300 450 900

1

-

-

... More
Fixed portion Frame for Fire rated Glazed Door :-Providing and fixing non load bearing fixed frame for fire resistant glazed Partition for 120 min Fire Rating, made out to a profile of dimension 60mm x 70 mm of 1.6 mm thick galvanised steel sheet as per test evidence suitable for fixing fire rated glass for 120 min of both integrity & radiation control (EW120) & minimum 15 min of insulation (EI15).The profile has to be fixed to the supporting construction by means of anchor fasteners of size M10 x 80, every 150 mm from the edges and every 500 mm (approx.) c/c. Linear measurement of frame shall be measured for payment. The frame shall be filled with mineral wool insulation of density min 96kg/m³. and finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge .

1094

-

-

... More
25 mm dia

2

-

-

... More
Terminals Anchor End - 1 Set

-

-

-

... More
(e) 40 mm nominal bore.

996

-

-

... More
3. All equipments, quantities and technical data indicated in this Schedule are for the Contractor’s guidance only, these are based on the documents prepared by the Services Consultant. This schedule must be read in conjunction with other documents. The Contractor shall be paid for the actual quantity of work executed by him in accordance with the approved Shop Drawings at the contract rates.

-

-

-

... More
For Matt Finish of Sizes 600mmX600mm .

22477

-

-

... More
Disinfecting C.I. / D.I. water mains by flushing with water containing bleaching powder at 0.5 gms per litre of water and cleaning the same with fresh water, operation to be repeated three times including getting the sample of water from the disinfected main tested in the municipal laboratory as per direction of Engineer in Charge.

-

-

-

... More
MCCBs for motor back protection should be motor duty type and the ratings should be selected as per Type II coordination chart of manufacturer

-

-

-

... More
EXIT SIGNAGE (Left)

70

-

-

... More
(vi) 19300

1

-

-

... More
Lot, Axially Split, Coupling, Coupling Guard, External type Mechanical Seal, Nut Bolts, Supports, Corrosion Resistant finish and all necessary accessories as required.

-

-

-

... More
4 nos. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Fire Survival Cable (For Booster Pumps at Roof Level of Main Building) Supply and Termination of Fire Survival Cables as per BS 7846, Stranded Annealed Bare Copper Conductor /950° Mica Tape Wrapped/Cross Linkable Zero Halogen Insulation/Cores Laid up together/Fibre Glass Tape Wrapped/Zero Halogen Inner Sheathed/GI Wire Strip Armoured/ Zero Halogen Outersheathed of 1.1KV grade as required .as per direction of Engineer in Charge. 4 C x 16 sq.mm

310

-

-

... More
(x) 0-63 A Ammeter with Ammeter selector switch & 63/5 C.T.s - 02 Sets

-

-

-

... More
Bus Bar

-

-

-

... More
2 Sets of 100/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Supplying fixing and connection P17 tempra combined units with 250V,16A,2P+E interlocked switched socket and surface mounted box IP66 Legrand Cat no.056661 or equiv. ((2 wheeler charging) as per directed by Engineer in Charge.

258

-

-

... More
Power plug wiring in PVC conduit (2x4 sq.mm):- Wiring for light / power plug with 2 x 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit along with 1 nos. 4 sq. mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required.

1620

-

-

... More
SITC of 230V single phase, 1200mm sweep ceiling fans with double ball bearing, complete with electronic step regulators, down rod as per mounting height from FFL and including all other fixing accessories as required. (FAN AND EXHAUST FAN)

2942

-

-

... More
Water Treatment Plant (De-Ironing: 100 Kld & sofner 130 Kld) Providing, installation, Testing & Commissioning of the following Equipment's, Machineries & Materials as per specifications including preamble , Drawings and accepted Design as per CPHEEO Manual for the process of treatment, including cost of all materials media resins, chemicals, puddle collars, sleeves . Inserts, manholes etc., cost of labour, tools and plants and accessories as per direction of Engineer-in-charge:: • Oxidation Chamber - 1 no, Capacity 50 cum/hr, • Multigrade Filter - 1 No, Capacity 50Cum/hr,• Activated Carbon Filter - 1 no. , Capacity 50 cum/hr, • Softener - 1 No, Capacity 50Cum/hr (after blending), • Hypo Chloride Dosing Pump - 2 Nos, Capacity 0 - 6 LPA of 2 kg/sq cm head, • Air Blower for Back washing - 2 Nos Capacity 0- 50 Cum/hr pressure 0.35 kg /sqm, • Flow Meter - 2 Nos

2

-

-

... More
DDC- 27

2

-

-

... More
(ii) 17340 CMH at SP at 20 mm WG

2

-

-

... More
6/32,amps, TPN

102

-

-

... More
VAV-02-1F-G 1465 440

1

-

-

... More
(xxxv) AH-3F-07* 33 28900 4

1

-

-

... More
Supply, Installation, Testing & Commissioning of Magnetic Door Contact for Door position feedback as directed by Engineer in Charge

38

-

-

... More
1 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
(f) 80 mm nominal bore.

12

-

-

... More
A 4 size Color Alarm Printer suitable for the application, with driver software as per directed by Engineer in Charge..

2

-

-

... More
(i) 200 A 4P MPCB - 02 No.

-

-

-

... More
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and nuts & screws etc. complete.

132

-

-

... More
(i) 0-300 Ammeter with Ammeter selector switch and 300/5 C.T.s -1 Set

-

-

-

... More
(x) 0-25 A Ammeter with ammeter selector switch & 25/5 CT's - 03 Sets.

-

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.as required. (but without charcoal or coke and salt)

302

-

-

... More
Exhaust System

-

-

-

... More
Providing and fixing of Insulating Elastomeric (a genric term that includes rubbers, latex and elastomeric compounds that may be natural or synthetic or a mixture or a combination of both) mat with ISI mark of 1 mtr wide and 2mm thick to withstand 1.1 KV dielectric strength as per IS 15652-2006 as per directed by Engineeer in Charge.

130

-

-

... More
Engine Hours indication

-

-

-

... More
Supplying, installing, testing and commissioning of Audio De Embedder Should repeat HDMI input signal up to 15 meters • Should extract HDMI audio signal and outputs as additional audio source Should support optical / coaxial digital audio and analog stereo audio • Should be HDCP 1.1 compatible • Should support Superior Video Quality – up to 1920x1080 (1080p) • Firmware should be upgradable • Should have CH2/CH5.1/Auto mode audio channel selection • Should support Dolby True HD and DTS HD Master Audio • Should support Audio on/off switch for HDMI output • Should be expandable to three levels – provides three levels of audio output for one HDMI at distance up to 45 m • Should integrate with Apple or equiv. TV for the perfect home entertainment system

1

-

-

... More
(v) AH-LGF-07 13 12200 4

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
2 Sets of 4000/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Supply, Installation, Testing & Commissioning of ceiling loudspeaker of minimum 4.25 inch driver and a 1 inch tweeter in a 2-way design with polypropylene woofer material and an IP rating of IP50, transformer with multiple taps of at least 30 - 15 - 7.5 - 3.75 watts at 100v and 30 - 15 - 7.5 - 3.75 - 1.75 watts at 70v, frequency response of at least 75 - 20KHz, dynamic power of at least 80 watts and the low impedance connection shall present a load of 16 ohms to the amplifier. The output SPL at 1m 1watt shall be at least 88 dB and maximum output SPL at 1m with full power shall be at least 108 dB. The loudspeaker shall include overload protection for failsafe operation as per directed by Engineer in Charge.

4

-

-

... More
Supply and fixing of following sizes Four compartment U-PVC DLP trunking for vertical distribution of power circuit wireing from ceiling upto Raceway. DLP Trunking material shall be non-corrosive and excellent resistance to minerals, acid, alkalies and detergents as per directed by Engineer in Charge.

-

-

-

... More
(xxxvi) AH-3F-08 15 14700 4

1

-

-

... More
(ii) 0-500 V Voltmeter with Voltmeter selector switch and control fuses - 1 Set

-

-

-

150

-

-

... More
(xIi) 1530 15

3

-

-

... More
(a) 100 A 4P MCCB – 1 No.

-

-

-

... More
ACSDB 01 AHU ROOM : Supply, installation, testing and commissioning of following distribution boards totally enclosed compartmentalized, cubicle floor mounted, indoor type IP:42, factory fabricated with 2 mm thick sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply suitable for 25 KA as per specifications and drawings. All Air Circuit Breakers shall be provided with Micro processor based Earth fault, short circuit and over current releases. Moulded case circuit Breakers shall be microprocessor based electronic trip. Fault level for all ACB/MCCB and bus bar shall be 25 KA, all the motor feeder shall be type-2 coordinated. ICU shall be equal to ICS=100% . As Direction of E/C

2

-

-

... More
Car Flooring:-Providing and Laying 18mm thick Mirror Polished Granite in pattern for LIFT with necessary cutting,grinding as per Drawing & Design with the full satisfaction of the Engineer in Charge & The Architect complete as per directed by Engineeer in Charge.

154.56

-

-

... More
Under Voltage & Over Voltage protection with protection release.

-

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.i) 150 mm nominal size dia having minimum wall thickness 5.00 mm

48

-

-

... More
1 Set of 100/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Car Door Finish: SLIDING DOOR STAINLESS STEEL FRAME HALF GLASS DOOR / STAINLESS STEEL DOOR / BRASS FINISH FOR VIP & VVIP LIFTOF 120MINUTE FIRE RATED.(ALSO COMPLY TO FIRE SAFETY NORMS)

-

-

-

... More
VAV-08-1F-G 2180 654

1

-

-

... More
1 Set of 100/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Incoming

-

-

-

... More
• Relay: 1 presence relay

-

-

-

... More
Providing & Fixing Stainless steel 304 Butt Hinge100MM X75MMX3MM with screw for Aluminium Door Shutter complete in all respect and instructions of the Engineer in charge.

1180

-

-

... More
VAV-06-3F-H 1695 509

1

-

-

... More
VAV-01-GF-A 3110 933

1

-

-

... More
(a) 200 A 4P MCCB – 1 No.

-

-

-

... More
VAV-05-GF-E 2815 845

1

-

-

... More
Incoming

-

-

-

... More
Supply, Installation, Testing & Commissioning of Microprocessor based networkable analogue expandable type addressable type sub fire alarm panel with suitable loop card and amplifier wattage . Each loop card and amplifer should have 20% spare capacity for future provision. Panel should have min. 640 character LCD display. The panel shall have access levels, capable of record upto 1000 event log history, sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump. Panel should operate with 240 volts AC power supply, automatic battery charger of suitable capacity , 24volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 min during an emergency conditions as required. The panel should have port to connect online printer.System is capabale of generate alarm condition if central processing unit fails. The network shall support min 64 panels / nodes per network.(UL 9th or latest Edition Approved and FM approved). Mounting accessories of main fire panel, electrical connectivity from nearest DB, civil works, excavation route and connectivity from main fire panel to service block shall be in the scope of bidder.(SUB FIRE ALARM PANEL IN SERVICE BLOCK -I & II) as per directed by Engineer in Charge.

4

-

-

... More
(d) R, Y, B phase indicating LED light with 2A MCB - 1 set

-

-

-

... More
(b) ON / OFF / TRIP Indicating Lights with control fuses – 1 Set

-

-

-

... More
Armoured 4 Core x 1 sq mm FRLS Al-Mylar Screened with drain wire, Cable for control cabling as per directed by Engineer in Charge

5000

-

-

... More
20mm nominal bore

349

-

-

... More
125 amps 25KA SC for 1 sec

24

-

-

... More
Capcaity ( CMH) Static Pressure ( mmof H2O)

-

-

-

... More
d) 5.5 KW Motor - 06 No.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Workstation with Intel® Quad Core, 2.8GHz or higher, 8 GB RAM, 100 GB free disk space, Dual Ethernet 10/100MBs, Software Requirements as directed by Engineer in Charge: * Microsoft Windows 10 (Enterprise) 64-bits * Microsoft .NET Framework v4.0 * Microsoft SQL Server. * SQL Server 2012 Enterprise Edition / SQL Server 2014 / SQL Server latest

2

-

-

... More
Ampere sentry Protection or equivalent

-

-

-

... More
Supply and installation of powder coated extruded aluminium 76 mm width Exhaust air louvers complete with aluminium bird screen as per specifications. As Direction of E/C

76

-

-

... More
Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete.S.S Stay Size 255 x 19 mm

514

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
3 Core x 6 Sq.mm Cable

1200

-

-

... More
SITC of Air Terminal 2.5 mtr. side wall ,confirming to EN 62561 and according to IS/IEC 62305 as per direction of Engineer-in-charge

40

-

-

... More
Under Voltage & Over Voltage protection with protection release.

-

-

-

... More
(i) 25 mm Dia

4

-

-

... More
d). Inbuilt Music on hold,

-

-

-

... More
50mm dia

1085

-

-

... More
400 mm dia. R.C.C. pipe.

1868

-

-

... More
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:6 (1 cement : 6 coarse sand) finished with a top layer 6 mm thick cement plaster 1:4 (1 cement : 4 fine sand) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (Note:-Using water proofing compound paid separately)

720226

-

-

... More
Supplying, fitting and fixing Storage type Water heater of "RACOLD" or equivalent approved make having inner/outer coated corrosion resistant body, high temperature and pressure safety devices, fixing lugs / bolts etc. and including plug top and electrical power supply 230 volts AC, single phase, 2 KW rating with lead wire connection upto 3 metres from the heater, suitable for high pressure water inlet 8 bar max. and drain out connections all complete operational as per direction of Engineer in Charge.

-

-

-

... More
(a) 100 mm dia pipe

120

-

-

... More
Incomer 1 Set of 3200A 3P ACBs 50 KA (EDO) microprocessor controlled with overload, short circuit having :

-

-

-

... More
(d) R, Y, B phase indicating LED light with 2A MCB - 1 set

-

-

-

... More
VAV-02-1F-A 4125 1238

1

-

-

... More
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes

16184

-

-

... More
(i) 0-200 Ammeter with Ammeter selector switch and 200/5 C.T.s -1 Set

-

-

-

... More
Server Room/Raised Flooring :-Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the Architectural drawings, as specified and as directed by Engineer-in-charge consisting of Grommet for Server Room/Raised Flooring

100

-

-

... More
Supply, Installation, Testing & Commissioning, Laying, Termination of 6 Core Fiber Optic Cable, Armoured SM as per Specifications as directed by Engineer in Charge

4000

-

-

... More
Outgoing

-

-

-

... More
300 mm width x 50 mm depth x 1.6 mm thickness

8

-

-

... More
Note: All metering current transformers shall be Class 0.5, 05 VA, cast resin type.

-

-

-

... More
Note: All metering current transformers shall be Class 0.5, 05 VA, cast resin type.

-

-

-

... More
(v) 80mm dia

3

-

-

... More
(i) 150 A, 415V, 3ph, 4 wire Aluminium busbar

-

-

-

... More
Providing, fixing and testing UPVC soil waste and vent pipes UV stabilize and conforming to IS: 13592 - Type-B including all fittings conforming to IS:14735 such as W.C. connector, bends, junctions, inspection doors, offsets, vent cowls, access pieces/plugs, cleanout plugs etc. clamps/ structural steel supports as required/directed at site, jointing with rubber ring and rubber lubricant including cutting holes in walls and making good the same as per direction of Engineer in Charge.

-

-

-

... More
1 Set of 1600/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
(d) 200 mm nominal bore.

3556

-

-

... More
4 Strip aluminium bus bar of 150 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
Outside Textured with paint WITH LOW VOC:-Providing and applying a uniform 2mm (+/- 0.25mm) thick Dolomite filler based Acrylic Texture of approved design/pattern with necessary primer (ON THE BASIS OF FREE MOCK UP/SAMPLE), including pre-preparation of the surface as per manufacturers specifications, approved sample panel, drawing & as directed by the Engineer-in-charge complete in all respect at all level.

722934

-

-

... More
Supply, Installation, Testing, & Commisioning of Response Indicator

272

-

-

... More
35mm thick Metal Door SIZE 900MM(W)X2100MM(H) Double Shutter Including Hardware (6nos. 100mmx75mmx3mm MS Butt Hinge, 2nos.300mm Long D-Type MS Handle Fabricated MS 20mm dia ROD, 2 nos.250mm Aldrop) complete in all respect.

4

-

-

... More
1 Set of 630/5A CTs of 10 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
(i) 1500 A, 415V, 3ph, 4 wire Aluminium busbar

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
DDC- 21

2

-

-

... More
Extra for each subsequent lead up to 25M beyond the initial lead of 50M (Maximum up to 150M by head load) as per specifition and direction of Engineering -in charges.(Note-Filling in foundation trenches and plinth)

400

-

-

... More
6 core 1.0 mm², PVC insulated, tinned copper conductor cable - shielded.

-

-

-

... More
(a) 9 ltr. Water type stored pressure Fire Extinguisher filled with water of TDS 3 to 4 PPM, Applicable fire class A, UTGS Pressure Gauge, Gross Weight 12 Kg, empty weight 4.3 Kg, Can Height 575mm, Diameter 180 ± 10mm, Discharge Time 35 Sec, Controllable discharge mechanism, Jet Range 7 Meters, Average Discharge is 95%, applicable on Class A, Fire Rating- 2A, Can Construction : Deep drawn & CO2 Mig welded, Brass forged valve with safety Pin is of SS material, Controllable discharge mechanism with EPDM Hose & Nozzle, Internal Coating – Plastic Lining, External Coating - Pure Polyester Powder coating (UV Resistant), Sheet metal thickness : 2mm, construction as per IS 15683:2006 and ISI Marked.

176.44

-

-

... More
1000 A FP ACB in Existing End feed Unit

4

-

-

... More
(vi) 65 mm dia

92

-

-

... More
Outgoing

-

-

-

... More
Incoming

-

-

-

... More
Providing & fixing aluminium Louvers (fixed type) of approved integrated anodised ( matt finished 15 micron thick) extruded sections . All aluminium sections shall be Polyester powder coated all complete including frame, louver and dash fasteners etc.payment shall be made on the basis of total weight. All complete as per drawing and direction of the Engineer-in charge.

481

-

-

... More
65mm dia. nominal inner dia.

848

-

-

... More
(ii) 0-500 V Voltmeter with Voltmeter selector switch and control fuses - 1 Set

-

-

-

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required. (for electronic Hooter and speaker zone)

320

-

-

... More
Neutral CT for Neutral Overload protection and Earth Fault sensing should be provided for all 3 pole ACBs for 3 phase 4 wire system.

-

-

-

... More
15 mm nominal outer dia .Pipes.

549

-

-

... More
2x37 kVAr LT power capacitor banks with 2 No. 30 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
1 Set of R, Y, B phase indicating light (LED type) with 2A , SP MCB, 10KA

-

-

-

... More
Outgoing

-

-

-

... More
(xi) 0-40 A Ammeter with ammeter selector switch & 40/5 CT's - 07 Sets.

-

-

-

... More
Above 35 sq. mm. and up to 95 sq. mm.

1160

-

-

... More
Supply, Installation, Testing, & Commisioning of Supply of manifold check valve for non return arrangement of Novel 1230 gas after discharge back into cylinder. as per direction of Engineer in Charge.

38

-

-

... More
11 no. 63A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
center to center along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm center to center & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be prepainted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7)

5820

-

-

... More
4x62.5 kVAr LT power capacitor banks with 3 No. 50 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
(i) 10200 25

2

-

-

... More
(a) 63 A 4P MCCB – 1 No.

-

-

-

... More
VAV-06-2F-H 1345 404

1

-

-

... More
4000 A, 65KA, IP 54

330

-

-

... More
Supplying, installing, testing and commissioning of CONFERENCE BUS CABLE 20M to be supplied from same OEM as Conference System as per directed by Engineer in Charge

2

-

-

... More
DDC- 46

2

-

-

... More
(ii) 0-500 V Voltmeter with Voltmeter selector switch and control fuses - 1 Set

-

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
1 Set of 2500A 3P ACBs 50 KA (EDO) microprocessor controlled with overload, short circuit having :

-

-

-

... More
4 Sets of 400 A 4P MCCBs 50 KA miroroprocessor based controlled with overload, short circuit and earth fault protections.

-

-

-

... More
Providing and fixing 50 mm dia CPVC Spout of length upto 300 mm, including concreting and water proofing around it. (For Potted plants etc) s per directed by Engineer in Charge.

100

-

-

... More
Providing and fixing S.S. round grating with round frame, 127 mm Dia overall size, glossy finish Chilly Cat. No. SK-005 or approved equivalent) including setting in floor with cement mortar 1:3 as per direction of Engineer in Charge.

1818

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Suitable Digital Input Module - Minimum 16 CH .

-

-

-

... More
Construction of grease trap chamber of internal dimensions 1800 mm x 600 mm x 1500 mm deep in 230mm thick brick masonry using first class country brick in CM 1:6 with RCC baffle walls in CC 1:2:4, including all earth work, centering, shuttering over a bed of 150mm thick 1:3:6 CC, plastering with CM 1:3, 12mm thick on internal, external, top surfaces and inside and exposed top surfaces finished smooth with a floating coat of neat cement, also providing and fixing RCC man hole cover & frame of size 560 mm dia HD20, foot rest, CC 1:2:4 for fixing the frame and cover, providing upvc pipe withTee 100 mm diameter on the inlet/outlet, that shall be covered in pipe work seperately. Complete all as directed and specified by Engineer in Charge. Note: CC 1:2:4 in the above Item is using 20mm graded granite aggregate obtained from approved quarry. With bricks of class designation 35

6

-

-

... More
Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. (Note- For Screed plastering, Hollor at roof)

434

-

-

... More
7 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(i) 32 mm Dia

12

-

-

... More
63 amps, TPN

150

-

-

... More
LLOP ON Delay,

-

-

-

... More
Supply, installation, testing and balancing of box type GI Volume Control Damper 18 G Frame, 20 G Blades, to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution complete as per specifications. As Direction of E/C

250

-

-

... More
(b) ON / OFF / TRIP Indicating Lights with control fuses – 1 Set

-

-

-

... More
GARDEN : 9W LED garden spike , Color Temp. 3000K Luminnaire, IP-65, Similar to BAJAJ CAT NO - BGSBL 9W LED WW or equiv. Sample luminaire shall be got approved by Engineer-in-charge / consultant.

72

-

-

... More
(ii) 3.0c x 6 sqmm

400

-

-

... More
4 Sets of 4000 A 4P ACBs 65 KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings.

-

-

-

... More
VAV-03-1F-F 3290 987

1

-

-

... More
4000 A, 415V, 4 strip, 50 KA, 50 Hz Aluminium Bus bar

-

-

-

... More
Carriage of Stone Chips upto 22KM.

23920.52

-

-

... More
(xxvii) AH-2F-06* 36 29700 4

1

-

-

... More
Vertical Riser for 225mm Width Raceways

390

-

-

... More
25 MMX 25MM

2500

-

-

... More
150mm dia

12

-

-

... More
1. Load / Speed: 20 Persons (1360Kgs.) / minimum 1.00 Mtr. Per Second. 2. Total Travel distance: (4.5+5.5+4.5+4.5) 19metre . 3.Machine Room:-YES. 4.Floor Display Char: LGF,GF & 3RD 5.Number of Landing Entrances: Three 6.Size of Lift Well: 2550X 2450 (MM Wide X MM Depth)

2

-

-

... More
(xvii) HRU-3F-07- 2100 CMH Ceiling Suspended

1

-

-

... More
(v) HRU-GF-06- 1600 CMH Ceiling Suspended

1

-

-

... More
Meeting Room-(CM) : Supplying, installing, testing and commissioning of VC system like Codec, Camera and Microphone that should be from the same OEM.Full HD 1080p camera, codec, Microphone Array, cables, and remote control. It should support H.323, SIP standards for communications, H.261, H.263, H.264 AVC/ SVC, H.264 High Profile, 1080p 60 fps, 1080p 30 fps, 720p 60 fps and 720p 30fps, content sharing using standard based H.239 and BFCP over SIP at resolution HD1080p60, audio from PC used for content sharing, should transmit both people and content both simutaneously to the far end location at 1080p 30fps, should support G.711, G.728, G.729A, G.722, G.722.1, AAC-LD or better, 20kHz bandwidth with crystal clear audio and stereo sound.Automatic Gain Control and Automatic Noise Suppression. Keyboard noise reduction and instant adaptation echo cancellation. 1 x HD input for connecting main HD camera. 1 x HDMI input for connecting PC/Laptop to share HD content . 1 x Microphone Input(Support for minimum 2 mics). 1 x 3.5mm stereo line-in. 2 x HDMI output for connecting main monitor & second monitor. 1 x 3.5 mm stereo line-out. 1 x 10/100/1000 LAN port. 2 x USB 2.0 for software upgrade and connecting external devices. 1 x RS-232 mini-DIN 8-pin, should support 1080p60fps with 10x optical zoom and 65° field of view, PAN Range of +/-100°, and Tilt of +/-20°, H.323 and SIP bandwidth up to 6 Mbps, IPv4 and IPv6 support from day one, Auto Gatekeeper Discovery, IP Precedence, H.323 based Packet Lost Recovery, should support atleast 6 sites at 720p. Media Encryption (H.323, SIP): AES-128, AES-256.Authenticated access to admin menus, web interface and telnet API.Local account password policy configuration, H224/H.281, H.323 Annex Q, H.225, H.245, H.241, H.239, H.243, H.460, should support native Lync server integrations,Auto sensing power supply. 125VA @ 230V @ 60Hz as per directed by Engineer in Charge.

1

-

-

... More
(xiii) VFDs in suitable enclosure shall be installed near the equipments for motors of following ratings:-

-

-

-

... More
Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

40

-

-

... More
Supply, installation, testing and commissioning of 2 nos. submersible sump pumps with motor in built, IP 68 enclosure, motor protection thermal switch, moisture sensors, and suitable for three phase 415 volt, 50 HZ, AC supply, 2850 rpm, handling particle size ranging upto 50 mm suitable for sewerage, with cast iron body and impeller, SS 410 shaft, 5 metre MS galvanized chain for pump lift, level controller for automatic On/Off operation, common control panel with direct on line starting for two numbers sump pumps with one working at mid level and both working at high level, timer unit for cyclic operation in each sump supplied with suitable water proof cable from panel to pump as per tender specification etc. as required all complete as directed by Engineer in Charge. Capacity – 200 lpm, head - 15 mtr & 3 HP approx.

20

-

-

... More
Supplying, fitting and fixing Electrical Control Panel Board suitable for outdoor installation of adequate size made out of 2mm thick CRCA M.S. sheet and M.S. flat painted with suitable enamel paint fitted with required electrical accessories of approved make suitable for submersible pump - motor set, described above, including Automatic Star Delta Starter, Main Switch, Single Phase Preventer, Overload Protection Device, Water Level Controller with two probes, one for low level audible warning and one for very low level for tripping of the motor with all required electrical works, Amp. Meter, Volt Meter with Selector Switch, Indicator Lamp, on & off push button, Danger Board etc. as required.(1W+1S) 2 nos of pump.) as per direction of Engineer in Charge.

42

-

-

... More
1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB

-

-

-

... More
4 Strip aluminium bus bar of 500 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
Auto-manual / test selector / switch - 3 Sets

-

-

-

... More
MCCBs above 200A ratings should be provided with Copper Spreader Links & Phase barriers

-

-

-

... More
100mm diameter UPVC. pipe

1065

-

-

... More
(vi) 0-250 A Ammeter with ammeter selector switch & 250/5 CT's - 03 Sets.

-

-

-

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour,royalty and taxes all complete as per building specification and direction of E/I(Mode of measurement compacted volume).

1692

-

-

... More
Breaker control switch - 1 Set

-

-

-

... More
Supply, installation, testing and commissioning of Submersible type non-clogging Pump motor set (1W+1S) or (2W+1S) as stated below of Pumps located in each sump in in Lower ground floor) of required drive (Motor HP), having discharge capacity and pumping head as described below with all electrical accessories viz.main switch and starter, auto on/off system with float arm (with fixed or flexible arm), over load protection relay, power cable and control cable from main switch and starter with auto on-off with dry running protection to respective motors, earthling having required M.S. galvanized supporting stay/ clamp etc. complete operational as per direction of Engineer in Charge.

-

-

-

... More
MFM shall have following parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, THD.

-

-

-

... More
Waterproofing of Roof Garden area : Providing and laying water proofing treatment on Roof Garden area consisting of following :-(Measurement on treated floor area only & Rate is inclusive all items. Quantity for Good soil for Horticulture & Landscaping consider in the Landscaping BOQ ) 1.Surface Preparation: All surfaces to receive the waterproofing coating to be mechanically cleaned properly so that there will be no dust, laitance, oil, grease. The mother slab has to be laid in slope to ensure proper drainage through the drain openings etc. 2.Coving:Coving to be done at all junctions by cutting V grooves of 20 mm x 20 mm and filling with cement-sand (1:4) mortar admixed with (Sika Top 77 /Nitobond SBR Latex of FOSROC/BASF Master Emaco SBR 2)of approved manufacturer with their direction. 3.Bore Packing:-Bore packing to be done at all pipe entries with suitable material (Sika Rep Microcrete 4 /Fosroc Nitobond SBR Latex/ BASF Master Emaco S 340) of approved manufacturer with their direction. 4.Water proofing product:- Supply and application of water proofing inside floor & wall upto full height & cover 300mm upto outside with appropriate material of minimum thickness 1.5mm (Sika LASTIC 450 I/ Nitoproof 600 FOSROC/BASF Master Seal HLM 5000)of approved manufacturer with their direction. 5.Covering with Screed plastering:-After curing Providing and applying 12mm thick plastering with Cement Mortar 1:4 admixed with integral waterproofing admixture (Sika Plastocrete Plus/Fosroc Conplast WL/BASF Master PEL 777) of approved manufacturer with their direction on wall & floor complete. 6. Finishing:-Finishing with Neat cement punning over plastering work.

1238

-

-

... More
Supply, Installation, Testing and Commissioning of LED spike light having wattage of 9W to 12W and minimum lumen output of 625lm. The lumianre should be IP65 rated. The housing of the lumianrie should be made of Aluminium. Color temperature should be 2700K. Similar to Philips "31386 Garden Spike 12w" or eqiv. Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

300

-

-

... More
Base Joint

280

-

-

... More
Supply, cutting, fabricating, welding, erecting & fixing in position of M.S. support for Fire fighting pipes & installations including painting with two coats of synthetic enamel paint of approved make & shade over a coat of approved steel primer and as instructed by E.I.C. Material shall conform to IS-2062

6000

-

-

... More
a. All materials, fixing materials, accessories, appliances tools, plants, equipment, transport, labour and incidentals required in preparation for and in the full and entire execution, testing, balancing, commissioning and completion of work called for in the item and as per Specifications and Drawings.

-

-

-

... More
Safety stud anchor M8x95/30

4

-

-

... More
1 set of Digital Ammeter with class-0.5 with 1 Nos. 3200/5A 15 VA CTs.

-

-

-

... More
1 run of cable

1468

-

-

... More
Waterproofing of Foundation Floor :- Providing and applying water proofing treatment over PCC of foundation consisting of following works :-(ACTUAL LAYING AREA TO BE PAID) 1.Surface Preparation: All PCC surfaces to be cleaned properly so that there will be no dust, laitance, oil, grease etc. 2.Waterproofing Membrane: Providing and applying a glass fibre reinforced, pressure sensitive membrane laid over substrate with overlaps seams of 75 mm (side) and 100 mm (end), a thickness of 3 mm -0.1/+0.1 mm (EN 1849-1), a cold flexibility of -2 °C (EN 1109) Membrane before laying reinforcement: ® WP Shield-103/ 1.2mm HDPE-P / Master Seal 730 PA (Note :- Approved applicator of approved Manufacturer execute the work followed by manufacturer specification, direction with precautionary measure)

58828

-

-

... More
(xx) AH-1F-05 19 16900 4

1

-

-

... More
Capacity – 600 lpm, head - 15 mtr & 5 HP approx.

4

-

-

... More
1 no. 100A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineering-charge.

24

-

-

... More
PMDB-3F (POWER MAIN DISTRIBUTION BOARD) ( THIRD FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 2 as per direction of Engineer-in-charge

2

-

-

... More
Outgoing

-

-

-

... More
(xi) AH-GF-03 18 14750 6

1

-

-

... More
VAV-03-1F-B 6645 1994

1

-

-

... More
VAV-08-GF-D/VAV-06-1F-C 2445 734

2

-

-

... More
Supply & Fixing in position as per Drawing & Design Ornamental Teak Wood moulding Bead size as follows finished with painting/ lacoured/French Spirit polished complete in all respect as per direction of the Engineer In charge.

-

-

-

... More
Supply of LED 595 X 595mm Surface mounted Luminaire with a nomial system lumen output of 3300 lumens and a minimum system efficacy of 80 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a CCT 5700k or 6500k, CRI 80, PF 0.95, an operating Voltage Range of 220V- 240V, Standard Deviation Colour Matching (SDCM) =3 to =5.The luminaire housing should made of powder coated metallic CRCA with high efficiency opal diffuser with a profiled cover. The total Power Consumption should be within 35W to 45W (including driver). Similar to Philips Make CIRRUS SURFACE "SM365 LED33 5000 PSU OD GR" or eqiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification Required: LM 79 & LM 80 . Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

600

-

-

... More
Bus Bar

-

-

-

... More
DDC- 13

2

-

-

... More
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.

127

-

-

... More
80 mm nominal bore.

28

-

-

... More
Supplying and fixing modular plate and cover in front on furniture, including providing and fixing 1 No- 6 pin 15/16 A modular socket outlet and 1 No- 15/16 A modular switch, connections etc. as required.

5616

-

-

... More
Supply 11 KV power cable of following size, Stranded, compact circular aluminium conductor, conductor screened with extruded semiconductor compound, XLPE insulated, insulation screened with extruded semiconductor compund in combination with copper tape, (0.3 KA for 1 second), cores laid up, inner sheathed with PVC, galvanised strip armoured earthed and overall PVC sheathed, black cable confirming to IS: 7098- Part- II- 1985 with latest amendments 3 Cx 300 sq,mm HT AND LT CABLES

360

-

-

... More
Set Selector Switch - 1 No.

-

-

-

... More
INDOOR CAMERA Supply, Installation, Testing & Commissioning of Ceiling mount Network Dome Camera with 1/2.8" CMOS Sensor, Progressive Scan, POE, 2MP, 3-9mm Varifocal Lens at f1.3, IK10 Rated for Vandal Protection and IP66, Built-in IR, 130dB WDR, motorized Auto Focus enabled, should Supports up to 128 GB cards, card not included), UL Listed and all features as detailed in technical specification. Camera should have built-in Video Analytics for enhanced Security as per Specifications and as directed by Engineer in Charge.

448

-

-

... More
Providing & fixing Stainless Steel H-type Pull Handle with SS finish size as follows with necessary screw etc. for flush Door shutter of approved Make complete in all respect as per direction of Engineer in Charge. 300MM overall Length DIA 16MM

858

-

-

... More
Post Top : LED 45W(±10%) decorative Post Top Luminaire with Die cast aluminium graphite grey powder coated finished housing, Polycarbonate opal diffuser Design Utilizes high brightness LEDs, Color temp. 3000K, Color Rendering Index ≥70,Standard Deviation Colour Matching (SDCM) 4, an operating Voltage Range of 220 - 240 V, Total Harmonic Distortion 10%, Driver Efficiency 85%, IP 65, PF 0.95, Surge Protection 5KV. Luminaire Performance: IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification: LM 79 & LM 80 Certificates. Min Delivered Lumens: 3375 lumen, suitable for mounting on 3.0M height (above ground lev.) GI Pole for the post top, similar to Bajaj Cat. No. BGCT W4 LED or equiv. Sample luminaire and paint shall be got approved by Engineer-in- charge / consultant.

188

-

-

... More
Extra for providing mechanical device chain and crank operation for operating rolling shutters.

232

-

-

... More
2 Sets of 400 A 4P MCCBs 50 KA miroroprocessor based controlled with overload, short circuit and earth fault protections.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Printable smart card for driver as per technical specification.:- 100 nos.

-

-

-

... More
3 NO - ON/OFF/TRIP indication light (LED Type) with SP MCB

-

-

-

... More
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials as per direction of Engineer-in-charge:.

-

-

-

... More
2 Core x 4 Sq.mm Cable

12

-

-

... More
(ii) 3.9 TR ( Medium Static)

4

-

-

... More
1 no. 320A 4P MCCB, 25 KA microprocessor controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
(x) 0-16 A Ammeter with ammeter selector switch & 16/5 CT's - 09 Sets.

-

-

-

... More
250mm diameter UPVC. pipe

1424

-

-

... More
(v) 1.2 mm

41

-

-

... More
Over Load relay

-

-

-

... More
Fuel Solenoid Relay,

-

-

-

... More
Clip On Partition for 195x50 Trunking

1680

-

-

... More
Supply, Installation, Testing & Commissioning of POP UP BOX: It should be a Hydraulic pop up box; It should have a VGA ,HDMI,AUDIO,USB,LAN X 2 Connectors; It should have 2 Un - switched AC Power 220V, 13 Amp Outlet, It should have an on/off Switch with indicator ; It should have a VGA ,HDMI,AUDIO,USB,LAN X 2 Connectors; It should have 2 Un - switched AC Power 220V, 13 Amp Outlet, It should have an on/off Switch with indicator as per directed by Engineer in Charge.

3

-

-

... More
(xxiii) AH-1F-07* 18 16700 4

1

-

-

... More
Carriage of Bricks lead upto (7P+1K=8KM)8KM.

17674.93

-

-

... More
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.

1934

-

-

... More
Supply, installation, testing & commissioning of the following all accessories required for Building Management System , including integration with chiller plant manager (CPM) with required gateway etc. and as required.

-

-

-

... More
Bus Bar

-

-

-

... More
Auxiliary contacts required for necessary interlocking of breakers.

-

-

-

... More
Ceiling Component:-Design , Providing , Fabricate & Fixing 6mm thick Plyboard with Veener of approved make pasting polish finished Plank Ceiling component (0.8 mm laminet at inner side) with necessary GI Supported member as per drawing & design with polish finish complete in all respect and as per direction of Engineer in Charge.(Shop drawing should be approved by the Architect before execution of the work)

70

-

-

... More
VAV-06-1F-A 2120 636

1

-

-

... More
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick.

145018

-

-

... More
Supplying, installing, testing and commissioning of a central control unit with integrated PC, inbuilt USB recording capability, control software package that can be controlled using the front panel display using control keys or can be accessed by connecting any VGA monitor, keyboard and mouse that shall allow fault monitoring and error diagnostics and full control over all delegate units and the audio and conference parameters including equalization, feedback suppression, microphone limiting, and conference modes and digital processor which shall supply 52.8 vDC power and control data through a network bus for controlling up to 40 discussion units. An Ethernet port shall be provided for network connection and control through third party digital control systems. The remote delegate discussion units connected to the central control unit shall be hot-swappable during a conference. Audio frequency response shall be 100Hz to 14kHz and Input voltage range shall be -18dBu to +18dBu (XLR In). Maximum output level shall be +10dBV with a signal-to-noise ratio of greater than 80dB A-weighted at +18dBV. Total harmonic distortion shall be less than 0.01% A-weighted at +6dBV In and Out. Power consumption shall be 245W as per directed by Engineer in Charge.

1

-

-

... More
(d) R, Y, B phase indicating LED light with 2A MCB - 1 set

-

-

-

... More
Thickness of powder coating should be 60 microns or more. Top roof should be well ventilated, especially with ventilation provided on the vertical side of the roof to enhance the hot air outflow while in operation. Roof should also have provision to mount atleast 4 nos. of 90 CFM cooling fan trays and there should be space for the cable entry from the top. Colour of the cabinet should be Black The structure and all its components should be made from CRCA Steel Material – at least 1.2mm thick The rack should be provided with 1 Heavy Duty Shelf of 390 mm Depth. Vertical power distribution units provided should have 6 outlets of 5/15 amp capacity. All cables used should be of ISI grade with 2.5sq mm cross sectional area. All the connecting ends must be tinned so as to avoid any loose wire strands. Rack should have the appropriate mounting provision for the multiple of these PDUs at the rear of the rack. Each Rack should be provided with one numbers of such power distribution units. Certifications: RoHS as per directed by Engineer in Incharge.

-

-

-

... More
Supplying, installing, testing and commissioning of 15Mtrs HDMI Cable : Crystal-clear video up to 4K DCI (4096 x 2160 @ 30Hz), 4K UHD (3840 x 2160 @ 30Hz), and 1080p @ 60Hz signal HDMI Ethernet Channel functionality: additional dedicated data channel supports networking HDMI (3D, Deep Color, 4K) and HDCP 2.2 compatible Gold-plated connectors for reliable transmissions 15 mtrs in Length RoHS-compliant as per directed by Engineer in Charge.

2

-

-

... More
Supply, Installation, Testing, & Commisioning of Novec 1230, CCOE Approved 80.0 Ltrs. Cylinder working at 34.5 bar pressure with Valve Assembly and arrangement for Supervisory Switch connection for monitoring cylinder pressure, a pressure gauge with a safety burst disc and safety cap. as per direction of Engineer in Charge.

16

-

-

... More
65 mm dia

16

-

-

... More
MDB (MAIN DISTRIBUTION BOARD ) ( SERVER ROOM ) as per direction of Engineer-in-charge

2

-

-

... More
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design.(a) 2.30 m deep with SFRC cover and frame (Heavy duty HD 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.

128

-

-

... More
1 Set of 1600 A 4P ACBs 50 KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings.

-

-

-

... More
Neutral CT for Neutral Overload protection and Earth Fault sensing should be provided for all 3 pole ACBs for 3 phase 4 wire system.

-

-

-

... More
Breaker control switch - 2 Sets

-

-

-

... More
(xiii) 0-16 A Ammeter with ammeter selector switch & 16/5 CT's - 06 Sets.

-

-

-

... More
300 mm width x 50 mm depth x 1.6 mm thickness

3336

-

-

... More
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

3208

-

-

... More
Providing & Fixing H-type Door Pull Handle for Aluminium Door Shutter.25mm dia X600mm overall Length, material SS 304, SS finish with necessary screw etc. complete in all respect and instructions of the Engineer in charge . (Make Godrej, Dorma, Hettich)

430

-

-

... More
Supply, Installation, Testing & Commissioning of Driver image capture module Automatic Number Plate Recognition (ANPR) Camera and Driver image capture Camera as per technical specification. :- 2nos.

-

-

-

... More
(vii) 6 A TP MPCB - 04 No.

-

-

-

... More
Supply, installation, testing & commissioning of Non - Chemical treatment system suitable of following line size as required and as per specification.

-

-

-

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required: 1000mm

10310

-

-

... More
Providing and fixing 4mm dia copper wire on surface or in recess for loop earthing as required.

1500

-

-

... More
Outgoing

-

-

-

... More
3.5 C x 400 sq.mm

10960

-

-

... More
A set of Sump pumps (Non-clogging type) having discharge capacity of each pump approx.60 cum/hr at 15 m. pumping head (2 working, 1 standby) Suction from sumps in in Lower ground floor, delivery to surface drain at ground level. Including MCC and allied works

2

-

-

... More
Supply and making straight through joint with heat shrinkable type including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (Note-NO PLASTERING OVER FALSE CEILING ONLY PAINTING OVER CONC. )

122736

-

-

... More
15mm nominal outer dia. Pipes

5141

-

-

... More
VAV-01-GF-A 2165 650

1

-

-

... More
1 Set of 200/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Supply, Installation, Testing & Commissioning of 1 KVA UPS along with battery for work station, backup time 30min. as per technical specification. :- 1no.

-

-

-

102

-

-

... More
8. The Contractor shall procure and bring Materials/Equipment to the site only on the basis of drawings approved for construction and shop drawings and not on the basis of Schedule of Quantities which are approximate only. This also applies to the Contractor’s requisition for Owner supplied materials.

-

-

-

... More
CONDENSAT DRAIN PIPING:Supply, installation, testing and commissioning of condensate drain UPVC piping as per BIS 4985 with necessary clamps, supports, hangers and fitting such as bend, tees, reducers etc. duly insulated with 9 mm thick class O NItrile foam as per the drawing and specifications. As Direction of E/C

-

-

-

... More
(v) 450 mm width X 62.5 mm depth X 2.0 mm thickness

60

-

-

... More
ii) Soft Water pumps (1W +1S) for makeup water at AC Plant volume flow : 20.00 m³/h, head : 30.00 m

2

-

-

... More
Levelling Course:- Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.” Note : Excess/less cement used than specified in this item is payable/ recoverable separately.

-

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
(g) 65 mm nominal bore.

2618

-

-

... More
Incoming

-

-

-

... More
Cooling Tower shall have controls based on wet bulb logic with variable speed drives to control the fan.

-

-

-

... More
Group C

476

-

-

... More
2 no. 63A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
630 amps 50KA SC for 1 sec

156

-

-

... More
Fan assembly shall be statically and dynamically balanced to G 2.5 grade as per ISO 1940.

-

-

-

... More
345 KVAR (Seleected actual Rating may be 437 KVAR) LT Capacitor Panel-2 as per directed by Engineeer in Charge.

2

-

-

... More
VAV-02-2F-B 4680 1404

1

-

-

... More
Supplying, fitting and fixing Mirrors of 6 mm thick plate glass bevelled edge Mirror including C.P. brass revolving fittings 3 mm ply wood board and C.P hinges to fix with mirror. (i) 600 x 450 mm size.

359

-

-

... More
VAV-01-GF-E 1596 479

1

-

-

... More
Diesel engine 4 stroke radiator cooled, electric start suitable BHP at 1500 RPM suitable for above prime power output at NTP conditions and conforming to BS 5514 & 5000, BS 649, IS 10000 & 1460, ISO 8528 & 3046, capable of taking 10% over loading for one hour after 12 hours of continuous operation at 40 deg C. The engine will be fitted complete with all required accessories.

-

-

-

... More
150 A, 25kA, FP MCCB

64

-

-

... More
(xiii) AH-GF-05 19 16550 4

1

-

-

... More
40 mm nominal outer dia .Pipes.

1271

-

-

... More
(iv) HRU-GF-02/03- 1800 CMH Ceiling Suspended

2

-

-

... More
EPABX SYSTEM as per specification with basic software as well as standard feature and specification as under as per directed by Engineer in Charge:

2

-

-

... More
Synchronizing Switch - 1 No.

-

-

-

... More
Video Conferencing Hall 212 Seater Supply, Installation, Testing & Commissioning of wireless digital Handheld Microphone with 18 or more channel, RF output 100mW or more, super cardiod pickup pattern, Frequency range : 1880 to 1930 MHz, Connectivity : RJ-45, Battery backup : 17 or more hr etc and complete as required with 1 nos 2 port charger of same OEM as microphone as per directed by Engineer in Incharge.

4

-

-

... More
Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete :For Size 100X60X2.5 mm

378

-

-

... More
FIRE RATED FANS:-Supply, installation, testing and commissioning of tube axial fan with adjustable pitched aluminium alloy impeller, TEFC squirrel cage induction IE2 motor with class 'H' insulation high temprature motor,1450 RPM direct drive arrangement, with fire rated canvus connection, GSS/MS sheet metal casing, and other accessories as required and as per specification of following capacities as per Schedule of Equipment. As Direction of E/C

-

-

-

... More
DG Panel Supplying, installation, testing & commissioning of cubical type LT panel suitable for 415V, 3 Phase, 50 Hz AC supply system fabricated in compartmentalized, design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC / SMC bus bar supports, with short circuit withstand capacity of 65KA for 1 Sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 2.5 sq.mm. zero halogen fire retardant insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears as per directed by Engineer in Charge.

-

-

-

... More
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.

14694

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement: 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 120cm x 90cm and 90cm deep including C.I. cover with frame (medium duty) 500mm internal diameter, total weight of cover and frame to be not less than 116 kg. (weight of cover 58 kg. and weight of frame 58 kg.) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

4

-

-

... More
5. Protective Relays, TVM/MFM shall have RS 485 Profibus/Modbus communication protocol for SCADA / BMS communication.

-

-

-

... More
Water Conductivity Sensor - 1 No.

-

-

-

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per "IS: 13983" with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required.

-

-

-

... More
(ii) 350 mm dia

1050

-

-

... More
(b) ON / OFF / TRIP Indicating Lights with control fuses – 1 Set

-

-

-

... More
32 mm dia vent pipe

4

-

-

... More
Supplying, installation, testing & commisioning of 360 degree Daylight/PIR sensor DUS360CR with an Infrared remote control reception (IR). The sensor features both Motion detection and daylight harvesting. cULus, CE, RCM, FCC, ICES-003 compliant as per direction of Engineer-in-charge.

1078

-

-

... More
VAV-04/05-1F-B 7125 2138

2

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)

50253

-

-

... More
ACDB 01 F : Supply, installation, testing and commissioning of following distribution boards totally enclosed compartmentalized, cubicle floor mounted, indoor type IP:42, factory fabricated with 2 mm thick sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply suitable for 25 KA as per specifications and drawings. All Air Circuit Breakers shall be provided with Micro processor based Earth fault, short circuit and over current releases. Moulded case circuit Breakers shall be microprocessor based electronic trip. Fault level for all ACB/MCCB and bus bar shall be 25 KA, all the motor feeder shall be type-2 coordinated. ICU shall be equal to ICS=100%. As Direction of E/C

2

-

-

... More
Making end termination of Water Proof PVC insulated Copper Cable of 3C x 2.5 Sq.mm. size suitable for the Submersible Motor as per direction of Engineer in Charge..

74

-

-

... More
(e) 250 mm nominal bore.

5992

-

-

... More
Bus Bar

-

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
FHC DOOR:- RED COLOUR PAINTED 35mm thick Metal Door SIZE 1500MM(W)X2250MM(H) Double Shutter Including Hardware(8nos. 100mmx75mmx3mm MS Butt Hinge, 4nos.450mm Long D-Type MS Handle Fabricated MS 20mm dia ROD, 1 no.250mm Aldrop and 2 nos. vision panel 3mm float glass Width300mmxHeight500mm) complete in all respect.

104

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

98

-

-

... More
Supplying, fitting and fixing C.P. brass liquid Soap container medium quality with screw and hinges etc.

400

-

-

... More
Supply INSTA Signage of approved make as Name Plate at any height, made of Stainless Steel of Grade 304 with approved Size of Lettering (English & Hindi ) ,Colour, Base Colour & Image as per direction of Engineer In Change. Size: 100X300

872

-

-

... More
(vii) 18900

1

-

-

... More
VAV-01-1F-G 4490 1347

1

-

-

... More
1 Set "ON /OFF" push button with 2A, 3P MCB, 10KA

-

-

-

... More
1 Set of 2500 A 3P ACB 65KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings

-

-

-

... More
1000 mm dia. R.C.C. pipe.

144

-

-

... More
VAV-01-LGF-F 2830 849

1

-

-

... More
3 Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
1 Set of 2500/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.)

-

-

-

... More
Breaker control switch - 2 Sets

-

-

-

... More
Over voltage relay

-

-

-

... More
Door Frame Design:- Design, Supply & fixing Venner fixed with adhesive over 12mm thick Ply board fixed over Teak Wood frame 50mmx50mm Decorative around Door Frame , column cladding & specified area. French polished finish as per direction & full satisfaction of the architect & the Engineer In charge complete in all respect. (Shop drawing should be approved by the Architect before execution of the work)

175

-

-

... More
Providing and fixing unplisticsize Polyvinyl Chloride (uPVC) Rigid pressure pipes as per IS 4985:2000 and fitting, having thermal stability for hot & cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. for pump main from sewerage sump to discharge point as per direction of Engineer in Charge.

-

-

-

... More
350 mm dia

12

-

-

... More
Outgoing

-

-

-

... More
1 Set of 3200 A 3P ACB 65KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings

-

-

-

... More
Terminals Mounting Track - 1 Set

-

-

-

... More
(i) Dia 250mm - (8.0 mm thick)

274

-

-

... More
VAV-09-2F-D 2720 816

1

-

-

... More
Note: All metering current transformers shall be Class 0.5, 10 VA, cast resin type.

-

-

-

... More
c) 100 mm dia - MS `C' Heavy class pipe. (Welded/Flanged Joints)

12885.022

-

-

... More
(x) Dia 32mm

102

-

-

... More
VAV-05-2F-B 2260 678

1

-

-

... More
SLP-04 (SUB LIFT PANEL-04 ) ( ROOF - EAST & WEST BLOCK) as per direction of Engineer-in-charge.

2

-

-

... More
Supplying, installation, testing & commissioning of CAT6A 1 Port Faceplate, Back Box & Key Stone with Labeling as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

1302

-

-

... More
Speed Lower Relay.

-

-

-

... More
Providing & fixing SS 304 Fire rated Surface door closer, with standard arm, silver finish (For Fire Metal Door)

428

-

-

... More
Providing sand cast iron drop connection externally for 60 cm drop from branch sewer line to main sewer manhole including inspection and cleaning eye with chain and lid, sand cast iron drop pipe and bend encased all-round with cement concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) with all centering and shuttering required, cutting holes in walls and making good with brick work in cement mortar 1:4 (1 cement : 4 coarse sand) plastered with cement mortar 1:3 (1cement : 3 coarse sand) on inside of the manhole wall, lead caulked joints between sand cast iron pipes and fittings, stiff cement mortar 1:1 (1 cement: 1 fine sand) joints between sand cast iron tee and S.W. pipe, making required channels complete as per standard design and specifications : 100 mm dia sand cast iron drop connection

4

-

-

... More
Supplying and laying 50 mm X 6 mm G.I strip on surface or in recess as earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) as per directed by Engineeer in Charge (For AC Plant Room - Service Building II)

440

-

-

... More
(ii) Nominal line size : 200 mm

6

-

-

... More
For Toilet Zone:-Oneside 120 minutes fire resistance HABITO / Fire block plaster board/ Tufbloc board & Otherside Moisture Resistant Board of approved make complete in all respect as per direction of E/I

196

-

-

... More
LIFT NO.5,6 &7 /18 , 19 & 20 Group of 3 Nos. Car as per directed by Engineeer in Charge.

-

-

-

... More
JET FANS TUNNEL VENTILATION:-Supply, installing, testing and commissioning of Ductless Ventilation / Jet fans as per Specifications for Normal Ventilation and Smoke Exhaust. Motor and Sound Attenuators shall be a composite, imported and certified component suitable for Fire Service and rated for a temperature of 300 Deg. C for a period of 2 Hours for Normal ventilation and Smoke Extraction application. The complete fan assembly with its casing, impeller and motor ( not only motor or one of the item ) shall be sourced from one manufacturer and certified and tested as per EN12101-3-2015 300 degree C for 2 Hrs operation. Each Jet Fan assembly shall connect to a composite PLC Panel controlled by CO Sensors / Fire Alarm System for Smoke Extraction.Actual no of jet fans & actual location of Jet fans will be decided only after CFD analysis by the contractor. As Direction of E/C

-

-

-

... More
Pipes, cables etc. exceeding 600 mm dia but not exceeding 900 mm

1090

-

-

... More
(i) 1.5 TR ( Medium Static)

4

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/ HDPE pipe as required.

-

-

-

... More
12 no. 63A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
24 Core x 0.75 Sq.mm Cable

300

-

-

... More
• Starter Panel with Cabling work with 5 Nos of feeder - 1 lot

-

-

-

... More
Supply, Installation, Testing, & Commisioning of Novec 1230, CCOE Approved 120.0 Ltrs. Cylinder working at 34.5 bar pressure with Valve Assembly and arrangement for Supervisory Switch connection for monitoring cylinder pressure, a pressure gauge with a safety burst disc and safety cap. as per direction of Engineer in Charge.

18

-

-

... More
(xvi) HRU-3F-06- 1900 CMH Ceiling Suspended

1

-

-

... More
All MCCB upto 250A Shall be Thermomagnetic and MCCB Greater than 250 A shall have Micro processor based release All CTs and PTs shall be cast resin type of Class 0.5

-

-

-

... More
2 Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Voltage Raise/Lower Joysticks - 1 NO -

-

-

-

... More
Refrigerant piping:-Supply and installation of interconnecting refrigerant piping with hard drawn copper including elbows and other necessry fittings duly insulated with 19(Gas lIne)/13 ( Liquid line) mm thick, Class O Nitrile Foam, , duly clamped and supported on GI tray as per the drawing and site conditions for connection between outdoor and indoor units. As Direction of E/C

-

-

-

... More
Providing and fixing 225 x 225x 65-90 mm ( pre-galvanized) floor raceways junction box made out of 1.5/1.6mm thick sheet steel as per specification with base and cover plate.

390

-

-

... More
Bus Bar

-

-

-

... More
(i) 80 mm dia

10

-

-

... More
Outgoing

-

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
(viii) AHU FAN SECTION --- 24450 ---

1

-

-

... More
DDC- 6

2

-

-

... More
(i) 0.63 mm, D ≤ 630 MM

1221

-

-

... More
Supply, Installation, Testing & Commissioning of Patch cord CAT-6A UTP, TIA / EIA 568-C.2, 1mt as directed by Engineer in Charge.

538

-

-

... More
Supply installation Testing and comissioning of MS structure of 30 M height suitable for 2 Nos DG set exhaust pipes MS structure shall have channel angles, plates, flat, beam sheet etc. as per design including bolts / dash fasterners/ nuts/hardwares etc. as required complete with primer & synthetic enamel paint of suitable quantity as per approved shade for exhaust stack, exhaust stack etc. complete in all respects. DG vendor shall prepare 5 set shop drawings, foundation deatil design and calculations for approval from E.I.C / Structure Engineer before starting execution of work. All statutory approval shall be in the scope of bidder as per directed by Engineeer in Charge.

30

-

-

... More
a) 04 KW Motor - 16 No.

-

-

-

... More
(d) ABC Type Fire Extinguisher Cap. 9 kg Filled with Mono Ammonium Phosphate Powder 90% confirms to IS 14609, Stored Pressure Type, UGTS Pressure Gauge, Gross Weight 13.3 Kg, Empty Weight 4.3 Kg, Can Height 575 mm, Diameter 180 ± 10mm, Discharge Time 31 Sec, Controllable discharge mechanism, Jet Range 6 Meters, Average Discharge is 90%, applicable on Class A,B & C and electrically started Fire, A Rating- 4A, B Rating 89B, Can Construction : Deep drawn & CO2 Mig welded, EPDM Rubber Hose with both end Aluminum clamped, Internal Coating - Epoxy Powder coating, External Coating - Pure Polyester Powder coating (UV Resistant), Brass forged valves with safety Pin is of SS material, Sheet metal thickness : 2.0 mm, ISI Approved IS 15683:2006.

44

-

-

... More
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :Second Class Teak Wood Panel

156

-

-

... More
DDC- 15

2

-

-

... More
Supply, Installation, Testing & Commissioning of 0.6 Mtrs HDMI Cable : Crystal-clear video up to 4K DCI (4096 x 2160 @ 30Hz), 4K UHD (3840 x 2160 @ 30Hz), and 1080p @ 60Hz signal HDMI Ethernet Channel functionality: additional dedicated data channel supports networking HDMI (3D, Deep Color, 4K) and HDCP 2.2 compatible Gold-plated connectors for reliable transmissions 0.6 mtrs in Length RoHS-compliant as per directed by Engineer in Incharge.

14

-

-

... More
Providing & fixing of approved Make Floor spring SS material & SS finish for weight upto 150kg with necessary nuts screw etc. for Panelled Door shutter complete in all respect as per direction of Engineer-in-charge.

136

-

-

... More
Supply & fixing shock treat chart duly mounted on a wooden frame with 5mm thick glass as required. (approximate front area 1.20sq.metre) in English and Hindi as per directed by Engineeer in Charge.

4

-

-

... More
Bus Bar

-

-

-

... More
1 nos. 20A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
(iv) 30200

1

-

-

... More
d) 3.7 KW - 01 No.

-

-

-

... More
100 mm nominal bore

44

-

-

... More
1 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

44627.6

-

-

... More
1 Set of 150/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
65mm dia

32

-

-

... More
Supplying, installation, testing & commisioning of 3 Loop DIN-rail mountable DALI Controller DDBC300-DALI allowing control of up to 192 DALI devices ,with inbuilt 3 x 20 A feed-through switched circuits for DALI driver mains supply and Integral DALI bus power supply. CE, RCM, IEC62386, RoHS compliant as per direction of Engineer-in-charge

50

-

-

... More
(xvii) AH-1F-01 30 27200 4

1

-

-

... More
Water Level Switches for indicating high & low level status in Cooling Tower sumps - 3 No.

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
1 Set of 1000 A 4P ACBs 50 KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings.

-

-

-

... More
Bus Bar

-

-

-

... More
(xiii) VFDs in suitable enclosure shall be installed near the equipments for motors of following ratings:-

-

-

-

... More
Space Heater - 150W - 1 No.

-

-

-

... More
VAV-01-3F-B 3210 963

1

-

-

... More
Providing & fixing Transfer Grill made of Aluminium Jindal section Light Duty as per Drawing & Design for Flush door Shutter complete in all respect. (Sample to be approved before execution)

27

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
(d) R, Y, B phase indicating LED light with 2A MCB - 1 set

-

-

-

... More
5 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
CONDENSER WATER PIPING Supply, installation, testing and commissioning of Condensor water Mild steel pipes (Heavy Class 'C' class) with all necessary fittings as per specifications like bends, elbows, tees, reducers, hanger, supports,etc as per IS 1239 upto 150mm dia and as per IS 3589 for 200mm dia & above. All other parameters as per the technical specifications given in the tender . Rate shall be inclusive of wraing and coating of condensor pipe. As Direction of E/C

-

-

-

... More
11 / 0.433 KV DRY TYPE TRANSFORMER Supply, installation, testing and commissioning of Cast Resin Dry Type 11/0.433 KV, 3 Phase, 50Hz, Dyn11 vector group, copper wound, class F insulation associated with winding temperature indicator/controller actuated by means of resistance temperature detector embedded in LV windings, indoor type Transformer with approximately 6.25% impedance, tappings for on load operation on HV side in steps of +5% to -7.5% @ 2.5%, having cable end boxes on HV side suitable for 3Cx300 Sq.mm XLPE cable of 11kV grade and 4000 Amp. bus trunking arrangement on LV side as applicable with neutral brought out separately including supplying and laying of copper conductor multi-core control cable from transformer to HT breaker for safety tripping, suitably mounted on M. S. channel i/c supplying and grouting of suitable M.S. channel and winding temperature indicator and alarm & trip contact with all accessories including bidirectional rollers and confirming to IS-2026 / IS 11171:1985 & as per specification attached complete in all respects as required at site as per directed by Engineeer in Charge. 1 NO PS Class CT for REF Protection 2500

6

-

-

... More
4C x 2.5 Sq mm

16

-

-

... More
(i) 16 A TP MCCB - 08 No.

-

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore.

1686

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :

-

-

-

... More
Supply, Installation, Testing & Commissioning of Emergency Release Switch as directed by Engineer in Charge.

38

-

-

... More
Plywood with Veneer Cladding:- Design, Supply , Fabricate & Fixing 12mm thick plywood of moisture resistant & termiteproof (Lab Test certificate to be provided) ply of approved make over Aluminium frame of required section fixed on plastered interior wall/ Partition wall for rigidly . Finished with Veneer pasted on plyboard one side duly french spirit polished complete in all respect as per Design. Location as per drawing and as per direction of Engineer in Incharge.(SHOP DRAWING TO BE PROVIDED & DULY APPROVED BEFORE EXECUTION OF THE WORK).

8718

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled. with overload, short circuit and earth fault protections.

-

-

-

... More
Supplying, installing, testing and commissioning of Centralized Automation Controller with programming: It should Supports various interface connections for hardware-software integration and the mobility of control -IR/Serial:- 4 x Programmable IR / Uni-directional RS-232 Port(2 x 4-Pole Terminal Block Connector). Serial:-4 x Programmable Bi-directional RS-232/422/485 Port (4 x DB9 Male Connector, configurable via pin assignments), 2 x Bi-directional RS-232 Port ; (2 x 3-Pole Terminal Block Connector).I/O:-4 x Programmable Digital Input / Output Channel (1 x 5-Pole Terminal Block Connector).Relay:-4 x Relay Channel (2 x 4-Pole Terminal Block Connector).VDC:-4 x 12 VDC Output Port (2 x 4-Pole Terminal Block Connector).Ethernet :-1 x RJ-45 Female, 10/100Base-T ."; It should have 1 x USB port for easy profile upload. ;It should support IR learning function for adding IR device drivers. ; It should Supports native KNX IP for building management systems. ; it should support Telnet, TCP, UDP, ONVIF, and PJLink compliant. ; It should Supports project file backup. ;It should have Web GUI for easy system configuration. ; it Supports SSH communication for data monitoring. ; it support Customizable GUI to be used on mobile devices and PC. ; it Supports ControlAssist that allows PC control (PC shutdown, media files, PowerPoint files. ; it should have Test tool to verify commands in action before uploading the profile to the Control Box ; it should have Built-in Database Generator for device driver setup and overall device management as per directed by Engineer in Charge.

1

-

-

... More
(ii) 63 A 4P MPCB - 12 No.

-

-

-

... More
(vii) 850 +935 15

22

-

-

... More
Motorised Butterfly Valve ( Condenser Line) (i) 250 mm dia

6

-

-

... More
4x62.5 kVAr LT power capacitor banks with 3 No. 50 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
75mm dia. nominal inner dia.

348

-

-

... More
20 mm dia

12

-

-

... More
Providing and fixing 2 WayON/OFF Motoraised Butterfly Valve, wafer type, with actuator suitable for water supply as per site, of CI body SS Disc PN-16 rating with coil of 220 Volt,50Hz AC suitable for horizontal/vertical installation, normally open with all electro mechanical accessories with one number Float switch sensor & relay for water tank level sensing with control wire connecting to motorised butterfly valve and exluding electrical supply wire and connection to actuator with operating voltage of 220 AC, suitable level sensor and relay for vertical/horizontal installation in water tank as per site condition suitably connected to motorised butterfly valve through control cable all inclusive with all electro mechanical accessories complete operational (Operation by SCADA system) all complete as required complete as per direction of Engineer-in-charge . 150 mm dia

32

-

-

... More
UMDB-FF UPS MAIN DISTRIBUTION BOARD) ( FIRST FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 1 as per direction of Engineer-in-charge

2

-

-

... More
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.34.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

502

-

-

... More
3.5 C x 25 sq mm A2XFY cable (28mm)

60

-

-

... More
13 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
VAV-03-GF-A /03-LGF-C/03-GF-A/01-1F-H 2675 803

4

-

-

... More
1 Set of 320/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329.

-

-

-

... More
6 no. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
8 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(ii) 150 mm width X 50 mm depth X 1.6 mm thickness

2000

-

-

... More
(b) ON / OFF / TRIP Indicating Lights with control fuses – 1 Set

-

-

-

... More
Upto 35 sq. mm

15000

-

-

... More
Outgoing

-

-

-

... More
RPM indication

-

-

-

... More
(I) COOLING TOWER (2w+1s) Supply, installation, testing and commissioning of FRP induced draft, counter flow, cooling tower with Structural frame work each of following heat rejection capacity with FRP water basin, PVC fillings with integral louvers and high efficiency drift eliminatiors, hot water distribution by gravity complete with statically and dynamically balanced axial flow, Direct driven fans with IP 55, TEFC IE2 induction motor with Variable Frequency Drive and temperature sensor suitable for operation on 415±10% volts, 50 Hz. AC supply, suction screen, make up with float valve and quick fill arrangement, overflow and drain connections, suitable inspection ladder, access arrangement for cooling tower interior, concrete foundation, stainless steel hardware and steel supporting structure, anti-vibration mountings, Level sensor/switch, Each VFD panel shall be provided with digital display showing electrical parameters like Voltage, Current and Power Consumption & compatible enough to take these data on BMS. etc complete as required and as per specification. As Direction of E/C

3

-

-

... More
VAV-03-3F-C 2070 621

1

-

-

... More
Providing and fixing water closet squatting pan (Indian type WC pan) with 100 mm sand cast iron / upvc P or S trap, upto 10 litre low level white PVC dual flushing cistern, Hindware cat no. 20070 & F850009 or equivalent make including flush pipe, with manually controlled device (push plates) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walla and floors where ever required as per direction of Engineer In Change.: White vitreous china Orissa pattern WC pan of size 580x430mm with integral type foot rest.

2

-

-

... More
Supplying , fitting & Fixing M.S Fencing / Railling/Grill in built with Solid and Hollow section (For round, square or rectangular) etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. all complete as per drawing ,design, prior approved sample and direction of the Engineer-in-charge.

313504

-

-

... More
Note - * - AHUs are with Electronic Clean air Filter

-

-

-

... More
UMDB-GF UPS MAIN DISTRIBUTION BOARD) ( GROUND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 2 as per direction of Engineer-in-charge

2

-

-

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

2212

-

-

... More
Shunt trip coil. - 1 Set

-

-

-

... More
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.

3586

-

-

... More
(ix) R,Y,B indication LED light with 2A MCB - 1 Set

-

-

-

... More
VAV-05-GF-D 3100 930

1

-

-

... More
LT PANEL - 4 (AT SUBSTATION) as per directed by Engineeer in Charge.

2

-

-

... More
(iii) 40 A 4P MPCB - 04 No.

-

-

-

... More
Incomer

-

-

-

... More
Incoming

-

-

-

... More
DDC- 48

2

-

-

... More
(xxviii) AH-2F-08 32 26200 4

1

-

-

... More
40 mm dia

2

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
MV cable laying upto 25 sq.mm. in ground:-Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc as reqired

400

-

-

... More
Car Entrance Protection: POWER OPERATED CENTRE OPENING SLIDING DOOR FRAME STAINLESS STEEL DOOR / BRASS FINISH FOR VVIP LIFT.(COMPLY TO FIRE SAFETY NORMS)

-

-

-

... More
GATE LIGHT : LED 45W(±10%) decorative Post Top Luminaire with Die cast aluminium graphite grey powder coated finished housing, Polycarbonate opal diffuser Design Utilizes high brightness LEDs, Color temp. 3000K, Color Rendering Index ≥70, Total Harmonic Distortion 10%, Driver Efficiency 85%, IP 65, PF 0.95, Surge Protection 5KV.Luminaire Performance: IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification: LM 79 & LM 80 Certificates. Min Delivered Lumens: 3375 lumen,Standard Deviation Colour Matching (SDCM) 4, an operating Voltage Range of 180 - 240 V, similar to Bajaj Cat. No. BGCT W4 LED or equiv. Sample luminaire shall be got approved by Engineer-in- charge / consultant.

16

-

-

... More
Providing and fixing UPVC trap ('P' or 'S') of self cleaning design with C.P. grating with or without vent horn complete, as shown in detailed drawing including inlet fitting wherever required including cost of cutting and making good the walls & floors as per direction of Engineer in Charge.

-

-

-

... More
Providing & fixing gun-metal fire brigade suction pipe coupling (draw-out connection) with nut for female coupling as per IS: 902-1974 complete with 100 mm dia GI suction pipe and 100 mm dia foot valve (to be connected to static tank).Provision of GI drop pipe and foot valve shall be made in fire water static storage tanks (GI pipe to be paid separately through appropriate item while cost of foot valve to be included). as per direction of Engineer in Charge.

2

-

-

... More
(xiv) AH-GF-05 21 18800 4

1

-

-

... More
Master trip relay

-

-

-

... More
40 mm dia

2676.871

-

-

... More
Constructing brick masonary chamber (for housing valve) in brick work with bricks of class 7.5 in cement mortar 1:4 (1 cement : 4 fine sand) with R.C.C top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand: 3graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :3 coarse sand: 8 graded stone aggregate 40mm nominal size) included plastering 12 mm thick with cement morter 1:3 (1 cement :3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand: 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete in all respect. Cost shall be inclusive of excavation in earth, shoring, dewatering, support to valve and access rungs as required to complete the work. Size 1200 x 900 x 1400 mm deep

-

-

-

... More
(iii) 75 mm diameter.

55

-

-

... More
VAV-08-1F-A 2820 846

1

-

-

... More
Providing and fixing WHITE VITREOUS CHINA PEDESTAL TYPE water closet (Anglo Indian type WC pan) with seat and lid, Hindware cat.no. 20012 upto 10 litre low level white PVC dual flushing cistern 3/6 litres including flush pipe, with manually controlled device (push plates) Hindware cat no. F850009 or equivalent make conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors where ever required as per direction of Engineer In Change.: WC pan with ISI marked white solid plastic seat and lid.

24

-

-

... More
50 mm dia

110

-

-

... More
(xxi) AH-1F-06* 39 35600 4

1

-

-

... More
VAV-01-GF-D 2648 794

1

-

-

... More
50 mm dia

12

-

-

... More
50mm thick Metal Door (For AHU Room)-SIZE 2000MM(W)X2400MM(H) Double Shutter with rock wool as acoustic, frame Including MS Hardware.(8nos. 100mmx75mmx3mm MS Butt Hinge, 4nos.250mm Long D-Type MS Handle Fabricated MS 20mm dia ROD, 2 nos.250mm Aldrop Finished painted as per approved colour) complete in all respect.

84

-

-

... More
(ii) 40 mm dia

105

-

-

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/ 40x3mm MS flat clamp)

848

-

-

... More
Supply, Installation, Testing of Discharge Pipe with Support and Fittings, CS Seamless to ASTM A-106 Schedule 40. as per direction of Engineer in Charge.

48

-

-

... More
Bus Bar

-

-

-

... More
(xxxiii) AH-3F-05 17 15750 4

1

-

-

... More
Close Command Relay

-

-

-

... More
UPSMDB (UPS MAIN DISTRIBUTION BOARD ) ( MAIN ELECTRICAL ROOM ) as per direction of Engineer-in-charge

2

-

-

... More
Meeting Room : Supply, Installation, Testing & Commissioning ofwireless digital Handheld Microphone with 18 or more channel, RF output 100mW or more, super cardiod pickup pattern, Frequency range : 1880 to 1930 MHz, Connectivity : RJ-45, Battery backup : 17 or more hr etc and complete as required with 1 nos 2 port charger of same OEM as microphone as per directed by Engineer in Charge..

6

-

-

... More
(xxxvi) AH-3F-07* 25 21350 4

1

-

-

... More
Incomer

-

-

-

... More
25mm nominal bore

343

-

-

... More
Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30 x 20 x 15cm cement concrete block 1:3:6 (1 Portland Pozzolana cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design.

478

-

-

... More
6 no. 40A 4P MCCB,Thermomagnetic controlled.

-

-

-

... More
4 Strip aluminium bus bar of 100 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
15mm nominal bore

109

-

-

... More
Incoming

-

-

-

... More
1 no. 100A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Supply, Installing, testing and commissioning of  Chassis+Fan Tray+ Sup6T+2xPower Supply with  (440G/slot) with 8x10GE, 2x40GE with Software license with 5 year warranty as per directed by Engineer in Charge Supply, Installing, testing and commissioning of  License for Chassis+Fan Tray+ Sup6T+2xPower Supply with  (440G/slot) with 8x10GE, 2x40GE with Software license (Already bundled with the switch) as per directed by Engineer in Charge

4

-

-

... More
(c) ON/OFF push button with control fuses – 1 Set

-

-

-

... More
10mm dia rebar at 200 mm depth

4

-

-

... More
8 Core x 0.75 Sq.mm Cable

12

-

-

... More
Providing and fixing M.S. holder-bat clamps of approved design to cast iron (spun)/uPVC pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :

-

-

-

... More
(iv) R,Y,B indication LED light with 2A MCB - 1 Set

-

-

-

85026.1

-

-

... More
Top roof should be well ventilated, especially with ventilation provided on the vertical side of the roof to enhance the hot air outflow while in operation. Roof should also have provision to mount atleast 4 nos. of 90 CFM cooling fan trays and there should be space for the cable entry from the top. Thickness of powder coating should be 60 microns or more.Colour of the cabinet should be BlackThe structure and all its components should be made from CRCA Steel Material – at least 1.2mm thickThe rack should be provided with 1 Heavy Duty Shelf of 390 mm Depth. Vertical power distribution units provided should have 6 outlets of 5/15 amp capacity. All cables used should be of ISI grade with 2.5sq mm cross sectional area. All the connecting ends must be tinned so as to avoid any loose wire strands. Rack should have the appropriate mounting provision for the multiple of these PDUs at the rear of the rack. Each Rack should be provided with one numbers of such power distribution units. Certifications: RoHS

-

-

-

... More
250 mm dia. R.C.C. Pipe.

900

-

-

... More
(x) 3.0c x 10 sqmm

80

-

-

... More
VAV-01-1F-F 5880 1764

1

-

-

... More
Supply, Installing, testing and commissioning of License of Access Points with 5 year warranty as per directed by Engineer in Charge

600

-

-

... More
VAV-09-3F-C 2965 890

1

-

-

... More
6 no. 20A DP MCCB, 25 KA Thermomagnetic controlled.

-

-

-

... More
DDC- 38

2

-

-

... More
Disinfecting C.I. / D.I. water mains by flushing with water containing bleaching powder at 0.5 gms per litre of water and cleaning the same with fresh water, operation to be repeated three times including getting the sample of water from the disinfected main tested in the municipal laboratory.

-

-

-

... More
Supply, Installation, testing and commissioning of piping accessories complete as required and as below as per directed by Engineeer in Charge.

-

-

-

... More
2x30 KVA (Both in Parallel) (42 AH with 2 battery banks with 40 Battery each) Total VAH=40320

2

-

-

... More
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.

68

-

-

... More
FLOORING FOR VISION IMPAIRED :-Providing and laying Stainless Steel 316(Marine Grade) Tactile stud ,Top of stud concentric circle Minimum Sizes top 35mm, depth of top portion 5mm, Bottom depth 12mm of 6mm dia having griping option. Fixed on any marble/granite flooring groove with polyurethane sealant, complete in all respect as per direction of Engineer-in-Charge.

11200

-

-

... More
The BTU meter should have a minimum sampling time for flow every 3 seconds and temperature 24 seconds.The heat meter should have a minimum accuracy of class 2 with CE conformance. The BTU Meter require for the following pipe size

-

-

-

... More
3C x 6 Sq mm

16

-

-

... More
VAV-02-3F-G 3500 1050

1

-

-

... More
100 mm width x 50 mm depth x 1.6 mm thickness

21.355

-

-

... More
MV cable laying upto 120 sq.mm. in ground:-Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of size not exceeding 120 sq.mm direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc as reqired

300

-

-

... More
For 150mm dia Pipe

10

-

-

... More
VAV-01-2F-B 3540 1062

1

-

-

... More
VAV-02/04-3F-H 1660 498

2

-

-

... More
1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
Supply, Installation, Testing and Commissioning of LED Recessed Downlighter with pressure die cast housing. Nominal system lumen output of 1200(±10%) lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 5700k or 6500K, CRI80 and Standard Deviation Colour Matching (SDCM) =3 to =5. The luminaire shall meet IP20 rating with THD10% and PF 0.9. The total power consumption should be with in 10W to 15W (including driver). Similar to Philips Make GREENPERFORM SLEEK "DN 296B LED12S-6500 PSU WH" or eqiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification Required: LM 79 & LM 80 . Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement. as per direction of Engineer-in-charge.

1417

-

-

... More
Providing & fixing Fire rated seal for grooved frame (For Fire Metal Door)

1460

-

-

... More
CHILLED WATER PIPE IN TRENCH Supply, laying/fixing, testing and commissioning of following sizes of chilled water MS ERW heavy class piping confirming to IS:1239/IS:3589 with necessary clamps, supports OF MS I SECTION in the Service Trench , anti-vibration mountings, clamps, Hangers and fittings such as bends, tees, reducers etc. (but excluding valves, strainers, gauges, etc.) duly factory insulated with providing and applying polyurethene foam, of density 36± 2 kg/m³ and cladded with minimum 5mm thick HDPE cladding complete as per specifications. As Direction of E/C

-

-

-

... More
UMDB-LGF UPS MAIN DISTRIBUTION BOARD) ( LOWER GROUND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 1 as per direction of Engineer-in-charge

2

-

-

... More
Chiller Power Input : ≤ 0.66 KW/TR

-

-

-

... More
900 mm width x 62.5 mm depth x 2.0 mm thickness

392

-

-

... More
Auto-manual / test selector / switch - 2 Set

-

-

-

... More
1 nos. 100A 4P MCCB Thermomagnetic controlled.

-

-

-

... More
CENTRAL CLEAN AIR FILTER/ CLEANER Supply, Installation, testing and commissioning, of central air cleaner/Filter air purification system that improves the indoor air quality through reducing harmful pollutants like particulate matter (PMx) minimum efficiency of 0.3 micron particulates has to be 93% or near to edge 11 HEPA class of multi circulating efficiency PM 2.5, allergens, pollen, bacteria, pathogens based on trap & kill technology, odor & VOC's etc. It should be a monobloc structured unit specifically designed for integration in Return Air path, to centrally capture and kill germs. It should have x4 working principles and it should be powder coated steel casing and should be self contained. The minimum life of central air cleaner unit should be more than 10 years without any consumable parts. A detailed selection chart as per each application zone shall be submitted for approval. Indian air pollution algorithm based intelligent maintenance system with inbuilt air flow sensing technology is must for all AHU for trouble free wiring connections. The central air cleaner must be equipped with ACF Granular Filtration Process for effective removal of odor & gases from the pollutant air. The contractor has to install these Filter in the AHU by the supplier only. The filter should have potential free contact/ NO-NC so that it can be taken on the BMS system. Max pressure drop should not exceed 6 mm WG. As Direction of E/C

-

-

-

... More
(i) 0-200 Ammeter with Ammeter selector switch and 200/5 C.T.s -1 Set

-

-

-

... More
32 mm dia

22

-

-

... More
(c) 25 mm nominal bore.

259

-

-

... More
(xii) 0-10 A Ammeter with ammeter selector switch & 10/5 CT's - 10 Sets.

-

-

-

... More
(v) 680 10

41

-

-

... More
Incoming

-

-

-

... More
(ii) Star Delta / DOL starter with ON/OFF indicating light, ON/OFF push buttons, control fuses, timers, contractors, overload relay with built-in single phase preventor, control fuses, wiring, interconnections suitable for following rating motor.

-

-

-

... More
CAPACITY & TAG TYPE

-

-

-

... More
80 mm nominal bore

32

-

-

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal

406

-

-

... More
Outgoing

-

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Mains voltage monitor relay.

-

-

-

... More
n) Busy call back

-

-

-

... More
VAV-03-1F-F 3595 1079

1

-

-

... More
Note: All metering current transformers shall be Class 0.5, 05 VA, cast resin type.

-

-

-

... More
Incomer

-

-

-

... More
Outgoing

-

-

-

... More
(xxxiii) AH-3F-02* 24 21300 4

1

-

-

... More
VAV-07-2F-H 2250 675

1

-

-

... More
PLC-CPU -Battery free CPU with on board Profibus / Ethernet Port - 1 No.

-

-

-

... More
(iii) 50 mm dia

28

-

-

... More
VAV-02-1F-E 2350 705

1

-

-

... More
Pumping out waste water including hire charge for pumps to be provided by the contractors including delivery and suction pipes, specials valves, etc. supplying fuel and lubricants, necessary operator and helper and removing the same on completion as per direction of flows from Nikashis, drains underground conduits etc. pump log book to be maintained.)

16000

-

-

... More
Providing, fixing, Chlorinated polyvinyl chloride (CPVC) pipes SDR11 , having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1m spacing . This includes jointing of pipes and fittings with one step CPVC solvent cement and cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge. Concealed work including cutting chases and making good the wall etc.

-

-

-

... More
e). Upto 6 party conference,

-

-

-

... More
1 Set of 630/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
(ii) Minimum 8 mm on Return air duct

14503

-

-

... More
IPLV - Minimum 9.7

-

-

-

... More
Upright type (68 deg.C) sprinkler

3202

-

-

... More
(ii) 150 mm width X 50 mm depth X 1.6 mm thickness

360

-

-

... More
(g) 100 mm nominal bore.

20

-

-

... More
Cooling tower inlet temperature: 36.4 °C

-

-

-

... More
Providing and fixing CP wall mixer with provision for overhead shower with 115mm long bend pipe on upper side connecting legs & wall flanges (Jaquar cat. No. CQT-23273UPR or approved equivalent) as per direction of Engineer in Charge.

42

-

-

... More
UMDB-GF UPS MAIN DISTRIBUTION BOARD) ( GROUND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 1 as per direction of Engineer-in-charge

2

-

-

... More
Supply, Installation, testing & commissioning of Factory fabricated Galvanized work Sheet metal Round duct as per SMACNA standard along with all accessories and fitings. The prices shall also include necessary galvanized duct supports consisting of fully threaded galvanized rods, galvanized angles or double-L bottom brackets, nuts, washers and anchor bolts (Hilti make) generally conforming to SMACNA/IS standards. All other parameters as per the technical specification given in the tender. As Direction of E/C

-

-

-

... More
2500 A, 415V, 4 strip, 50 KA, 50 Hz Aluminium Bus bar

-

-

-

... More
LMDB-FF (LIGHTING MAIN DISTRIBUTION BOARD) ( FIRST FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 2 as per direction of Engineer-in-charge.

2

-

-

... More
b) 03 KW Motor - 01 No.

-

-

-

... More
VAV-02-GF-C/03-GF-C/04-GF-C/05-GF-C/ 2635 791

4

-

-

... More
For 100mm dia Pipe Class-II

206

-

-

... More
• Housing: Plastic housing

-

-

-

... More
Incoming

-

-

-

... More
Supplying, installation, testing & commissioning of CAT6A Keystone Jack, T568 A/B Wiring for Voice as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

7070

-

-

... More
Providing & fixing Vertical Venetian Blind of Skipper or approved make and pattern over Window including fittings & fixtureas as per Drawing & Design complete in all respect as per direction of the Engineer In charge.

7010

-

-

... More
1 Set of 100/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
VAV-06-2F-F 4700 1410

1

-

-

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required. (For LIFT to trip the electrical power at the time of alarm conditions from LIFT panel.)

62

-

-

... More
Supplying, installing, testing and commissioning of an antenna module operating in both the 2.4 GHz and the 5 GHz frequency band, connecting to the central unit via the device cable, featuring 3 omnidirectional rod antennas with a coverage area of 30 m (100 ft) radius, adjustable RF output power from 25 to 100 mW, power consumption shall of 6W as per directed by Engineer in Charge..

1

-

-

... More
Multi Function Meter(MFM) shall have following parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, THD.

-

-

-

... More
(c) ON/OFF push button with control fuses – 1 Set

-

-

-

... More
4 WAY (8+12), Double door, Vertical type (Lighting SDB)

10

-

-

... More
3.5 C x 300 sq.mm

10

-

-

... More
(h) 100 mm nominal bore.

2

-

-

... More
Supply, Installing, testing and commissioning of Indoor Access Point 802.11AC AP, INT ANT WR with 5 year warranty as per directed by Engineer in Charge

600

-

-

... More
a) Providing and fixing gun metal full way valve with C.I. wheel of approved quality (screwed end) an complete as per specification and direction of Engineer-In-Charge.

-

-

-

... More
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete :

-

-

-

... More
600 mm dia. R.C.C. pipe.

476

-

-

... More
(ii) 9350 20

1

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
(iii) 6800 25

1

-

-

... More
Metering

-

-

-

... More
(iv) 0-16 A Ammeter with Ammeter selector switch & 16/5 C.T.s - 08 Sets

-

-

-

... More
Auto Relay

-

-

-

... More
Supply, Installation, Testing & Commissioning of Audio De Embedder Should repeat HDMI input signal up to 15 meters • Should extract HDMI audio signal and outputs as additional audio source Should support optical / coaxial digital audio and analog stereo audio • Should be HDCP 1.1 compatible • Should support Superior Video Quality – up to 1920x1080 (1080p) • Firmware should be upgradable • Should have CH2/CH5.1/Auto mode audio channel selection • Should support Dolby True HD and DTS HD Master Audio • Should support Audio on/off switch for HDMI output • Should be expandable to three levels – provides three levels of audio output for one HDMI at distance up to 45 m • Should integrate with Apple or equiv. TV for the perfect home entertainment system as per directed by Engineer in Charge

1

-

-

... More
(v) HRU-GF-04- 1600 CMH Floor Mounted

1

-

-

... More
Supplying and laying 50 mm X 6 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection / terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) as per directed by Engineeer in Charge (For Pump Room - Srvice Building I )

300

-

-

... More
Supply, Installation, Testing & Commissioning of POP UP BOX: It should be a Hydraulic pop up box; It should have a VGA ,HDMI,AUDIO,USB,LAN X 2 Connectors; It should have 2 Un - switched AC Power 220V, 13 Amp Outlet, It should have an on/off Switch with indicator as per directed by Engineer in Charge.

1

-

-

... More
(iii) 25 A TP MPCB - 03 No.

-

-

-

... More
Supply, installation, testing & commissioning of the following light fixtures complete with lamps, led driver, electronic ballast / Dalli Ballast etc complete in all respect . The product should conform to Luminaire Performance: IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification: LM 79 & LM 80 . The product should have a constant current driver, built in heat sink. LED lamp should be certified with ENEC, and IEC. All accessories required for mounting at surface/ recess /wall as mentioned in BOQ and drawings conforming to relavant IP protection and IS codes.Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 C x 6 mm2 (19mm)

960

-

-

... More
8 WAY (8+24), Double door, Vertical type (Power SDB)

124

-

-

... More
6.Application of Thermal Insulation:-Providing and fixing polyethylene film over 75 mm thick extruded polystyrene rigid insulation XPS board external use of required size on roof top by overlap (Thermal Insulation Paid in separate item) 7.Roof Tiles:-Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) etc.( Roof tiles work Paid in separate item)

49744

-

-

... More
1 no. 100A 4P MCCB, 25 KA Thermomagnetic controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
1 no. 320A 4P MCCB, 25 KA microprocessor controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
(vi) 600 mm width X 75 mm depth X 2.0 mm thickness

100

-

-

... More
VAV-03-2F-F 2470 741

1

-

-

... More
VAV-06-GF-D 1624 487

1

-

-

... More
(vii) 50 mm dia

118

-

-

... More
(vii) 12.7 mm

462

-

-

... More
(viii) 14550

1

-

-

... More
5 LB capacity Novec 1230 , DLP Assembly with automatic valve, push in connector for tube,5LB Novec 1230 gas , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation. as per direction of Engineer in Charge.

142

-

-

... More
Providing ,testing & retain 6 LEVER PAD Lock BRASS BODY , SS shakle corrosion free with 3 NOS. KEY for Aldrop.Minimum Shackle - Diameter - 9.5 mm, Body diameter 80mm & weight minimum 350gms as per direction of Engineer in Charge.

447

-

-

... More
SITC of Air Terminal 1.5 mtr. side wall,confirming to EN 62561 and according to IS/IEC 62305 as per direction of Engineer-in-charge

8

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.( POINT, CIRCUIT, SUBMAIN WIRING AND SOCKET)

-

-

-

... More
One set of 0-500 Volts voltmeter of 96 mm x 96 mm with selector switch and protection MCB.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Dual Channel Digital Power amplifier, 2 x 120Watts @ 100V / 4Ω; Bridgeable to 1 X 240Watts @ 100V / 8 Ω; Power Amp Topology : Class D; PSU Technology : SMPS; Convection cooled; Power Supply : SMPS; Output Voltage Taps : 100V - 70V - 50V - 35V - 4Ω; Protection Circuit : Over Current, Over temperature, DC Offset; Frequency response : 50 - 20KHz; S/N ratio : 98 dB A-Wieghted; THD: 0.1% @ 1KHz A Wieghted ; Power Consumption 300W; 1U 19" rackmount as per directed by Engineer in Charge.

1

-

-

... More
MV cable laying upto 120 sq.mm. in same trench without sand and cover:- Laying of one number additional PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of size not exceeding 120 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as reruired, but excluding sand cushioning, protective covering.

300

-

-

... More
Supply of following sizes of 1.1KV grade XLPE insulated PVC sheathed armoured aluminium, aluminium conductor power cables as per IS:7096 complete as required as per specification. As Direction of E/C

-

-

-

... More
Supply, Installation, Testing & Commissioning of digital audio network server that shall be implemented on a RJ-45 connector and shall support Ethernet connection for programming and control on a RJ-45 connector. The server shall have internal DSP processing. The server shall include 4 channels of General Purpose Input and Output connection (GPIO) for sending or receiving logic signals. The programming of the GPIO ports shall be software configurable. The server shall include a RS-232 connection for control data transmission and such operation shall be software programmable. The server shall include a Universal Serial Bus (USB) connection on a standard USB-B type connector. The server shall be software configurable to stream up to 8 channels of digital USB Audio Class 1 transmission either into or out of the server or simultaneous input and output. The server shall provide 12 balanced input connections for receiving of microphone or line level analog audio signals on screw-down, removable connectors. The input connections shall include Acoustic Echo Cancellation (AEC) hardware and firmware, the parameters, routing and operation of which shall be software programmable. The server shall provide 8 balanced output channels for the transmission of microphone or line level analog audio signals on screw-down, removable connectors. Each individual channel shall have its own dedicated connection. The server shall provide front panel OLED identification of server power, status, alarm, and activity as well as system-wide alarm. The server shall be rack mountable (1RU) and feature software-configurable signal processing, including but not limited to: signal routing and mixing, equalization, filtering, dynamics, and delay, as well as control, monitoring, and diagnostic tools. The server shall be CE marked, UL listed and shall be compliant with the RoHS directive as per directed by Engineer in Incharge.. .

2

-

-

... More
Shunt trip coil. - 1 Set

-

-

-

... More
Supply, Installation, Testing & Commissioning of LC Pigtail, SM as per Specifications as directed by Engineer in Charge

408

-

-

... More
(iii) 32 mm dia

260

-

-

... More
Protection Relays MFM Shall have RS 485 Modbus / Profibus Communication protocol for SCADA / BMS communication.

-

-

-

... More
VAV-01-3F-G 1395 419

1

-

-

... More
1 set of Digital Ammeter with class-0.5 with 1 Nos. 2500/5A 15 VA CTs.

-

-

-

... More
Number of Landing Entrances: As mentioned below

-

-

-

... More
3200 A, 50KA, IP 54

50

-

-

... More
VAV-07-1F-B 3965 1190

1

-

-

... More
2 Set of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
SITC of GI Strip 25x6mm for Interconnecting Earth Pits as per direction of Engineer-in-charge.

3700

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work,using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All Works above plinth upto floor V level. Extra for providing richer mixes at all floor levels.Note:- Excess/less cement over the specified cement content used is payable /recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)

9360

-

-

... More
PARKING AREA LIGHTING : Surface Mounted Waterproof (IP65) LED Luminaire with System Wattage 40W(±10%), Housing virgin polycarbonate, Cover virgin polycarbonate, Luminaire Efficacy100, Color Temp. =5700, Color Rendering Index ≥80, THD 10%, Driver Efficiency 85, IP 65, PF. 0.95,Luminaire Performance: IS10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification: LM 79 & LM 80 Certificates. Min Delivered Lumens: 3800 lumen, Standard Deviation Colour Matching (SDCM) 4, an operating Voltage Range of 220 - 240 V, similar to Bajaj Cat. No. BIPC 40W LED or equiv. Sample luminaire shall be got approved by Engineer-in- charge / consultant.

598

-

-

... More
Safety stud anchor M20x170/30

4

-

-

... More
3 no. 40A 4P MCCB

-

-

-

... More
(xi) 17400

1

-

-

... More
Safety stud anchor M24x200/30

4

-

-

... More
VALVES & STRAINERS : Supply, installation, testing and commissioning of following valves, strainer, in the chilled water piping complete with companion flanges, nuts, bolts, gaskets, supports, etc. and duly insulated and painted as per specifications. As Direction of E/C

-

-

-

... More
Supply, installation, testing and commissioning Approved make Submersible type non-clogging Pump motor set (2 nos. of Pumps located in each sump in semi-underground pump house & U.G connecting corridor) of required drive (Motor HP), having discharge capacity and pumping head as described below with all electrical accessories viz.main switch and starter, auto on/off system with float arm (with fixed or flexible arm), over load protection relay, power cable and control cable from main switch and starter with auto on-off with dry running protection to respective motors, earthling having required M.S. galvanized supporting stay/ clamp etc. complete operational as per direction of Engineer in Charge. A set of Sump pumps (Non-clogging type) having discharge capacity of each pump approx.20 cum/hr at 15 m. pumping head (1 working, 1 standby) Suction and delivery to surface drain at ground level. Including MCC and allied works

4

-

-

... More
b. Wastage on materials and labour

-

-

-

... More
b) 7.5 KW - 01 No.

-

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
VAV-02-1F-F 3875 1163

1

-

-

... More
Providing & Fixing Concealed Flush Bolt SS 304 12" Long with SSS finish for Aluminium Door Shutter with necessary screw etc. complete in all respect.

162

-

-

... More
4000 A, 50KA, IP 54

260

-

-

... More
Carriage of Sand upto 22KM.

57977.23

-

-

... More
2 Sets of 1600 A 4P ACBs 50 KA (EDO) microprocessor controlled with overload, short circuit and inbuilt earth fault protections with adjustable settings with electrical and mechanical interlocking arangement.

-

-

-

... More
Size - 250X500

420

-

-

... More
Smoke spill application (Exhaust fans) suitable for 250/300ºC operating temperature for 120 minutes as per standard BS EN12101-03,2015 and tested and certified by an independent international fire laboratory. The fan shall be CE marked/stamped.

-

-

-

... More
(xii) Dia 20mm

10

-

-

... More
Providing and fixing CP pillar cock auto closing pressmatic system instead of pillar tap (Jaquar cat. No. PRS - 031 or approved equivalent) as per direction of Engineer in Charge.

49

-

-

... More
VAV-08-3F-C 5365 1610

1

-

-

... More
Cable Termination Supply and making indoor cable end termination with heat shrinkable joining kit complete with all accessories including lugs suitable for the following size of 3 C, XLPE aluminium conductor cable of 11 kV grade as required. 3C X 300 sq mm.

20

-

-

... More
(d) 32 mm nominal bore.

2060

-

-

... More
4 Strip aluminium bus bar of 150 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
A special agency of sufficient credential duly approved from the architect & the Engineer in Charge before execution the Interior Work.(Shop drawing should be approved by the Architect before execution of the work)

-

-

-

... More
Supply and fixing of closed cell elastomeric self adhesive Nitrile rubber insulation on supply and return air duct as mentioned below:- As Direction of E/C

-

-

-

... More
3 nos. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Fouling Factor of Condenser & Cooler : As per data sheet

-

-

-

... More
9 Sets of ON/OFF/TRIP indication lights (LED type) with SP MCB

-

-

-

... More
Supplying, installing, testing and commissioning of Video Extender It should Extends the distance between HDMI source and HDMI display It should Implements HD Base T - Lite extension technology using only one Cat 5 cable to connect the transmitter and receiver. It should be HDMI (3D, Deep Color, 4kx2k); HDCP Compatible. It should support Long distance transmission - up to 70m. It should Supports resolutions of up to Ultra HD 4kx2k and 1080p Full HD. It should selects the optimum EDID settings for smooth power-up and highest quality display. It should Supports up to 340MHz bandwidth for high performance video. It should Supports Dolby True HD and DTS HD Master Audio. It should have Max. Data Rate 10.2 Gbps (3.4 Gbps Per Lane). It should support Max. Resolutions / Distance Up to Up to 4K@35m (Cat 5e/6) / 40m (Cat 6a/Cat6); 1080p@60m (Cat 5e/6) / 70m (Cat 6a/ Cat6). It should support Operating Temperature 0 - 50°C. It should have support Temperature -20 - 60°C.It should have support 0 - 80% RH, Non-Condensing as per directed by Engineer in Charge.

1

-

-

... More
2 no. 63A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Design, supply fabricate and fixing Semi Utilized Structural Glazing system with double (DGU) /single glazing for Door portion securely bonded to framework to ensure absolute water tightness, with profile either straight or segmented curve in plan consisting of main panel work of Mullions and Transoms made out of specially designed extruded aluminium section having 15-20 Microns Anodized in approved colour. Fixed at all levels, elevation and heights to the RCC elements with necessary clamps,brackets and anchor fasteners, made of shall be Mild steel Hot Dip galvanized with washer and shall confirm to IS : 4759 -1996. All gaskets shall be EPDM with all necessary flashing, floor seal, smoke seal, sealants etc. to make system fully weather and sound proof & water tight. Proposed glazing should be bonded to frame by mean of Structural sealant of Dow cornice995 and weather sealant shall be Dow Cornice 789. All spacer tape should be Norton or equivalent etc. complete with fixing Glass as per direction of the Engineer in Charge , inclusive of all except supply of Glass will be paid separately.(Glass fixing charges, Shutter Hardware of approved quality included in this item) (a) For Spandrel or Fixed Area

6308

-

-

... More
Each capacitor bank must have 1 set of on/off indication LED type.

-

-

-

... More
100mm dia

36

-

-

... More
CHILLED WATER PIPING ABOVE FALSE CEILING , VERTICAL SHAFT AND IN PLANT ROOM Supply, laying/fixing, testing and commissioning of following sizes of chilled water MS ERW heavy class piping confirming to IS:1239/IS:3589 with necessary clamps, supports, anti-vibration mountings, hangers and fittings such as bends, tees, reducers etc. (but excluding valves, strainers, gauges, etc.) duly insulated with CFC free machine cut shiplap joint pipe section polyurethane foam of density 36± 2 kg/m³ with approved adhesive of low VOC, wrapped with imported glass cloth of 10 mil with two times protective coating as required and as per specifications. As Direction of E/C

-

-

-

... More
Server Room/Raised Flooring :-Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the Architectural drawings, as specified and as directed by Engineer-in-charge consisting of Airflow Grill/Grated Panel for Server Room/Raised Flooring

50

-

-

... More
1600 A, 415V, 3 strip, 50 KA, 50 Hz Aluminium Bus bar

-

-

-

... More
(xxii) AH-1F-06* 21 19200 4

1

-

-

... More
Supply, installation, testing and commissioning Approved make Pump motor set (2 nos. of Pumps located in pump room) of required drive (Motor HP), having discharge capacity and pumping head as described below with all electrical accessories viz.main switch and starter, auto on/off system with float arm (with fixed or flexible arm), over load protection relay, power cable and control cable from main switch and starter to respective motors, earthling having required M.S. galvanized supporting stay/ clamp etc. complete operational as per direction of Engineer in Charge.

-

-

-

... More
Supplying, installation, testing & commisioning of following Capacity breakers in the Existing End feed Unit as per direction of Engineer-in-charge

-

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work,using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All Works upto plinth. Extra for providing richer mixes at all floor levels.Note:- Excess/less cement over the specified cement content used is payable /recoverable separately.All Works upto plinth For Design mix M-30 Grade

23266

-

-

... More
(xv) HRU-3F-03- 2000 CMH Ceiling Suspended

1

-

-

... More
Supply, Installation, Testing and Commissioning of LED Recessed Downlighter with pressure die cast housing. Nominal system lumen output of 1500 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a CCT 5700k or 6500k, CRI 80, PF 0.95, an operating Voltage Range of 220V- 240V, Standard Deviation Colour Matching (SDCM) =3 to =5. The luminaire shall meet IP20 rating with THD10% and PF 0.9. The luminaire housing should made of pressure die cast aluminium . The total Power Consumption should be within 12W to 16W (including driver). Similar to Philips Make GREENPERFORM SLEEK "DN 296 LED15S-6500 PSU WH" or eqiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification Required: LM 79 & LM 80 .Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

586

-

-

... More
• Emergency release button

-

-

-

... More
PRECISION AIR CONDITIONING UNIT:-Supply, installation, testing and commissioning of air cooled DIRECT EXPANSION MICROPROCESSOR BASED BOTTOM, DISCHARGE PRECISION A/C UNITS as per the specifications complete with All four sides doubled skin sandwich panels with insulation, air cooled condenser with stepless variable speed fans for winter operation, Single/Multiple Circuit Scroll Compressor each with Condensers with Stepless Fan Speed controller , evaporator coil with hydrophilic coating, Electronically commuted brushless motor EC fan, Electronic Expansion Valve, suitable for environment friendly refrigerant, Single stage electric heater , variable capacity auto-modulating humidifier, Stainless Steel Drain Pan, Water Leak Detector, Oil Separator and vibration isolator. The unit refrigerant circuit shall have factory installed Solenoid Valve, Liquid receiver and service valves. Motor shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase AC supply and external static pressure shall be 300 Pa. Outdoor unit motor protection should be with IP-54 protection and should be weather proof. PAC shall have bottom throw and top suction. Auto sequencing of the unit for equal run time should be integral part of the micro-processor. The unit shall have RS 485 card for BMS monitoring

-

-

-

... More
450 mm width x 50 mm depth x 2.0 mm thickness

720

-

-

... More
4 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
1 Nos. ACB (EDO Type) microprocessor based 4P, 4000A 65 KA

-

-

-

... More
UMDB-SF UPS MAIN DISTRIBUTION BOARD) ( SECOND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 2 as per direction of Engineer-in-charge

2

-

-

... More
Painting with two coats of Synthetic enamel paint of approved shade & brand over a coat of Red Oxide Zinc chromate primer. For the following sizes(NB) pipes prior to application of primer the surface should be changes dirt, rust, rough subtance etc. including painting of legends and direction as per the approval of completed the Engineer -in- charge . Outer surface for any dia pipe

1628.05

-

-

... More
Screed Concrete for levelling Course:-Providing & Laying Screed Concrete of M-30 Grade Average 50mm thick to maintain proper slope over GI Chicken wire mesh in 1 inch (about 2.5 cm) diameter, wire gauges 19 gauge (about 1 mm wire) to 22 gauge (about 0.7 mm wire) before execution of waterproofing work duly maintaintained by proper curing complete in all respect as per direction of the Engineer in charge.

40362

-

-

... More
(f) 50 mm nominal bore.

1864

-

-

... More
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520. (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads.

-

-

-

... More
VAV-05-GF-D/VAV-03-1F-H 3450 1035

2

-

-

... More
(iii) 15 mm Dia

4

-

-

... More
80 mm dia

40

-

-

... More
(a) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :

492

-

-

... More
Single Phase

-

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
TNC switch

-

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
1 no. 320A 4P MCCB, 25 KA microprocessor controlled with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
Incoming

-

-

-

... More
Supply, installation, testing and commissioning of factory built, cabinet type, Vertical Floor Mounted Air Handling Unit in double skin construction for following capacity at required static pressure complete with factory fabricated independent sections, housing the various components e.g. backward curve fan, TEFC blower IE2 motor suitable for operation on 415 ± 10% volts, 3 phase, fan efficiency shall not be less than 60%. 50 Hz AC supply with variable frequency drive (VFD) including DDC and sensors, copper tube aluminium finned direct expansion cooling coil, connection kits, Control boxes, pre filters , electronic expansion valve, corded remote and power and control wiring, drain pump , Sequential panel, drain connections, drain piping as per drwings, additional charge of refrigerant, anti-vibration mountings etc. as required and as per "schedule of equipment" and specifications. As Direction of E/C

-

-

-

... More
VAV-06-2F-D 2490 747

1

-

-

... More
Supplying, installing, testing and commissioning of detachable 15" gooseneck microphone with a super-cardioid capsule, frequency response at 190 Hz to 14.5 kHz, sensitivity at 1 kHz of 38 mV/Pa and maximum SPL level of 120 dB. The super-cardioid microphone shall be from the same OEM as conference system as per directed by Engineer in Charge.

7

-

-

... More
4 Strip aluminium bus bar of 500 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
Shunt trip coil. - 2 Set

-

-

-

... More
PRIMARY CHILLED WATER PUMPS -Supply, installation, testing and commissioning of Factory mounted vertical SPLIT COUPLED types Centrifugal Chilled water primary pump set with IE2 Induction motor of class 'F' insulation complete with TEFC, IP 55 protection, suitable for 415±10%, 50 Cycle each capable of delivering the specified flow rate, complete with other accessories, and all basic components, suction guide, Axially Split, Couplings, Coupling Guard, High tensile steel shaft, Bronze impeller, External type Mechanical seal, Bronze shaft sleeves Nuts, Supports and Corrosion-resistant finish, etc. & all necessary accessories as per relevant std. Pumps shall be insulated with insulation of same material & thickness as the connected pipe. All other parameters as per the technical specifications given in the tender. (2W+1SB) As Direction of E/C

6

-

-

... More
VAV-05-1F-F 3300 990

1

-

-

... More
Providing and fixing false ceiling at all height including Providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm center to center, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm center to center, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm center to center, shall be fixed in a direction Perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every

-

-

-

... More
4 X 10 sq. mm + 2 X 6 sq. mm earth wire

27944

-

-

... More
(d) R, Y, B phase indicating LED light with 2A MCB - 1 set

-

-

-

... More
Refrigeration Load : 325 TR (Actual) ( 2 W+1SB)

-

-

-

... More
1 Set Breaker ON / OFF / TRIP indicating lights with control MCB’s.

-

-

-

... More
200 mm diameter S.W./PVC pipe

5

-

-

... More
VAV-01/02/03/04-GF-C 3420 1026

4

-

-

... More
(b) ON / OFF / TRIP Indicating Lights with control fuses – 1 Set

-

-

-

... More
c) 04 KW Motor - 01 No.

-

-

-

... More
Outgoing

-

-

-

... More
Structural Steel for Plate Girder & Composite Superstructure for DOME:-(Specialized agency having sufficient credential of Plate Girder Fabrication & Errection should be nominated & getting approval from the Architect/PMC/Engineer In charge for execution this items & Fabrication Drawing should be approved before execution of the work) Supply, fabrication, assembling & erection of High tensile Steel structure as per IS 2062 to proper line, level and camber as per approved drawings and technical specifications section 1900 complete including transportation and handling, painting with LOW VOC Enamel paint of approved shade over coat of red lead primer all surfaces of steel work including all labour consumable other material machinery tools and tackles complete as per specification and directed by engineers including furnishing of detailed erection scheme and getting the same approved from the Architect/PMC, including drilling, welding, riveting, grinding supply of bolts, nuts, washers, fixtures etc. at site as per the direction of Engineer-in-charge .

1363774

-

-

... More
Incomer

-

-

-

... More
VAV-09-1F-A 5535 1661

1

-

-

... More
VAV-04-2F-E 2695 809

1

-

-

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 180mm x 180mm square and weighing not less than 440 grams.

332

-

-

... More
Incoming

-

-

-

... More
4. No alteration whatsoever is to be made to the text or quantities of this Schedule unless such alteration is authorised in writing by Client / Consultant. Any such alterations, notes or additions shall, unless authorized in writing, be disregarded when tender documents are considered.

-

-

-

... More
VAV-03-2F-C 5850 1755

1

-

-

... More
1 Set of 160 A 4P MCCBs 50 KA miroroprocessor based controlled with overload, short circuit and earth fault protections.

-

-

-

... More
(ii) 14 HP

4

-

-

... More
Supplying, installation, testing & commissioning of 90 watt RGB wallwasher Light, Protection : IP65 Class 1, Input Voltage : 220V AC, Operating Voltage : 24V DC, Power Consumption : 90 watt, Beam Angle : 60 deg, Control Mode : DMX, Housing : Aluminium Alloy, Operating Temp : -20 to 50 deg, 3 pin XLR input/output,

384

-

-

... More
Providing and fixing G.I pipe as sleeves for Fire Fighting work into beam all complete as per drawing and direction of engineering in-charge.

-

-

-

... More
5 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
b) 3.7 KW Motor - 02 No.

-

-

-

... More
Dia 50 mm - ( Cooling tower makeup line )

-

-

-

... More
(ii) 40 A TP MPCB - 03 No.

-

-

-

... More
Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile, rotary stitched double webbed white with 6 mm reveal profile (white/black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles.

6193

-

-

... More
LMDB-3F (LIGHTING MAIN DISTRIBUTION BOARD) ( THIRD FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 1 as per direction of Engineer-in-charge

2

-

-

... More
Supplying and Fixing following way, three pole and neutral sheet,MCB DISTRIBUTION BOARD, 415 VOLTS,on surface/recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate ,interconnections,phosphatized and power painted including earthing etc.as required.(without MCB/RCCB/ISOLATOR)S/F VERTICAL TYPE T.P. MCB MD :-SUB DISTRIBUTION BOARD

-

-

-

... More
Incoming

-

-

-

... More
Supply, installation, testing and commissioning, of wall/window type exhaust propeller fan with mounting ring, arm, impeller, motor with class ‘F’ insulation, IP- 54 Motor, capacitor, support, pressed steel wall frame, vibration isolators, fixed type aluminium louvers with bird screen, nut bolts for use on 220/240 volts, single phase, 50 Hz, power supply with all accessories, ancillary work, epoxy powder coating etcas required and as per specifications. As Direction of E/C

-

-

-

... More
Supplying, fitting and fixing Mirrors of 6 mm thick plate glass bevelled edge Mirror including C.P. brass revolving fittings 3 mm ply wood board and C.P hinges to fix with mirroras per direction of Engineer in Charge.

340

-

-

... More
(iv) 5270 15

1

-

-

... More
Head – 30 M

-

-

-

... More
(c) 65 mm dia pipe

400

-

-

... More
Providing & fixing MS cabinet (to enclose draw-out connection as per Item above) fabricated from 16 g MS sheet with full front glass door and locking arrangement duly painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and suitably mounted on a raised masonry paltform as required (Approx 0.6 m x 0.6 m x 0.45 m). as per direction of Engineer in Charge.

2

-

-

... More
Outgoing

-

-

-

... More
Providing and fixing C.I. wafer type single plate check valve body CI FG 220, seat Nitrile / EPDM, Flap CF8/ stainless steel all complete as per direction of Engineer-in-charge :

-

-

-

... More
5 NO - ON/OFF/TRIP indication light (LED Type) with SP MCB

-

-

-

... More
(a) 200 A 4P MCCB – 1 No.

-

-

-

... More
a) 15 KW Motor - 01 No.

-

-

-

... More
Accept PB Blue -Test Push Button with 1 NO Contact - 1 No.

-

-

-

... More
Bus Bar

-

-

-

... More
(iii) 26605 CMH at SP at 20 mm WG

12

-

-

... More
(g) 80 mm nominal bore.

4

-

-

... More
VAV-07-1F-E 2985 896

1

-

-

... More
(b) 25 mm nominal bore.

2.48

-

-

... More
1 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Fittings: LED LIGHT & FAN

-

-

-

... More
2. All CTs and PTs shall be cast resin type.

-

-

-

... More
(i) 0.50 mm

15165

-

-

... More
VAV-04-1F-F 3995 1199

1

-

-

... More
Size - 150X150

180

-

-

... More
1 No. 32 Amps. TPN MCB.

-

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations, etc. in layers not exceeding 20cm. In depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift up to 1.5m.(For Other than Civil Work)

553.44

-

-

... More
Differential Pressure Switch, Air

432

-

-

... More
BTU METER

-

-

-

... More
(xxix) AH-3F-01 27 24900 4

1

-

-

... More
Position of Machinery: Directly Above The Lift Well-GEARLESS

-

-

-

... More
Bus Bar

-

-

-

... More
2x500 KVA (Both in Parallel) (200 AH with 6 battery banks with 40 Battery each) Total VAH=192000

2

-

-

... More
(v) 80 mm dia

46

-

-

... More
VAV-05-3F-F 1235 371

1

-

-

... More
7 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
VAV-06-1F-D/01-2F-A 2340 702

2

-

-

... More
Application of Thermal Insulation Insu Board over Roof:-Providing and fixing polyethylene film over 75 mm thick extruded polystyrene insulation XPS board external use of required size on roof top by overlap/Tongue and Groove, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having R value 1.73 sqm.K/W, water absorption 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardant property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water proof tape, fully covered by polyethylene film complete in all respect as per the directions of Engineer-in-Charge.

40362

-

-

... More
Number and Position of Car Entrances: 1 (ONE), IN FRONT ONLY

-

-

-

... More
300 mm width x 50 mm depth x 1.6 mm thickness

3000

-

-

... More
1x12.5 kVAr LT power capacitor banks with 2 No. 10 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
2 Sets ON / OFF / TRIP indicating lights with SP MCB’s.

-

-

-

... More
4 no. 63A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/HUME/ METAL pipe as required. Above 120 sq. mm and upto 400 sq. mm

80

-

-

... More
VAV-05-1F-B 3115 935

1

-

-

... More
Testing, Commissioning & Handing Over

-

-

-

... More
• Protection: IP 40

-

-

-

... More
Bus Bar

-

-

-

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20 mm diameter round bar.

840

-

-

... More
Outgoing

-

-

-

... More
Extra for Labour charges Over 3metre height for 125mm thick reinforced designation 75 A brick work in C.M. ( 1 : 4) in superstructure for each floor/over Roof

13392

-

-

... More
(ii) 25 A TP MPCB - 02 No.

-

-

-

... More
Internal Textured with paint WITH LOW VOC:-Providing and applying a uniform 2mm (+/- 0.25mm) thick Dolomite filler based Acrylic Texture of approved design/pattern with necessary primer (ON THE BASIS OF FREE MOCK UP/SAMPLE), including pre-preparation of the surface as per manufacturers specifications, approved sample panel, drawing & as directed by the Engineer-in-charge complete in all respect aat all level.

4308

-

-

... More
Manual Relay

-

-

-

... More
VAV-04-2F-D 1525 458

1

-

-

... More
(xiii) 3.0c x 2.5 sqmm

60

-

-

... More
Duty parameters (each pump)

-

-

-

... More
DDC- 31

2

-

-

... More
5 no. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
VAV-02-1F-D 2845 854

1

-

-

... More
VAV-02-LGF-F 3250 975

1

-

-

... More
450 mm dia NB pipe 4.85 mm thick plate

230

-

-

... More
Bus Bar

-

-

-

... More
VAV-05-1F-E 3180 954

1

-

-

... More
Supply, Installation, Testing & Commissioning of 12 Port LC Duplex 1U 19" Rack Mount LIU with Panel, Splice tray and necessary accessories and fully Loaded, as per the specifications as directed by Engineer in Charge.

24

-

-

... More
Supplying, fitting and fixing C.P. brass Towel rail of size 20 mm x 600 mm with bracket container.

724

-

-

... More
Bus Bar

-

-

-

... More
Cooling tower outlet temperature: 32.2 °C

-

-

-

... More
** - AHUs are with Pre & Carbon Filter

-

-

-

... More
FOR DOOR SIZE- 2000MM(WIDTH)X2400MM(HEIGHT) Double Leaf Shutter.

922

-

-

... More
CHILLER PACKAGE/WATER COOLED SCREW CHILLER PACKAGE (2w+1s) Supply,Installation,Testing and Commissioning of Factory-packaged Water cooled liquid chillers with UL Listed / Certified Motor, VSD driven motor suitable for 415±10% volts, 50 cycles, AC supply, ASME/GB stamped shell & tube Condenser, Evaporator, suction, discharge valves, relief valve, Oil filter, suction filter, muffler, safety switch & pressure relief valves, low flow Flooded chillers complete with anti-freeze thermostat, cooling thermostat, Variable orifice or electronic expansion valves, liquid line strainers, shut-off valves, cooler/evaporator with nitrile rubber or equivalent insulation with 24 G aluminium cladding, interconnecting refrigerant piping, fittings, suction line insulation. Pre-wired control system including automatic & safety controls with microprocessor based control panel, flow sensors at chiller & condenser, display and key pad, oil heater and service valves, automatic oil return system, all interconnecting unit piping, Vibration Isolator, Victaulic coupling and matching flanges, all interconnecting unit control and power wiring, starter panel, provision for refrigerant and oil charge, Refrigerant isolation valve & all necessary accessories as per relevant std. All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with acrylic paint. Chiller RCC foundation with Vibration Isolators etc. as required. All other parameters as per the technical specifications given in the tender. As Direction of E/C

3

-

-

... More
Providing designation 75 A brick work in C.M. ( 1 : 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.

6658

-

-

... More
Providing and laying at or near ground level factory made Kerb or Channel stone of M-25 grade cement concrete in position to the required line, level and curvature,jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by Engineer-in-charge)

4

-

-

... More
Compressor: Single/Multiple

-

-

-

... More
Outgoing

-

-

-

... More
Outdoor Humidity & Temperature Transmitter

2

-

-

... More
VAV-02-3F-C 3130 939

1

-

-

... More
Bus Bar

-

-

-

... More
Incoming

-

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
600 mm width x 50 mm depth x 2.0 mm thickness

10

-

-

... More
Bus Bar

-

-

-

... More
2 No. 150 mm dia dial type pressure gauges.

-

-

-

... More
7 no. 20A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Engine Stop PB Red -Test Push Button with 1 NC Contact - 1 No.

-

-

-

... More
Supply and laying of UTP 4 pair 23 AWG CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair CAT6 Unshielded, Twisted Pair (U/UTP) Cable, frequency tested upto 700Mhz with Third Party Certificate etc., complete with required accessories for installation including civil work complete with all the systems are in the scope of bidder. Sample shall be got approved by E.I.C. / consultant.

-

-

-

... More
MCCBs for motor back protection should be motor duty type and the ratings should be selected as per Type II coordination chart of manufacturer

-

-

-

... More
(xvi) AH-GF-08 26 23300 4

1

-

-

... More
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. (For FFt system.)

2170

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Mini Bollard : 5W Warm White (3000K) LED Mini Bollard With pressure die-cast Aluminium housing that is powder-coated to prevent any corrosion in your outdoor installation, luminaire cover/diffuser is made of PC/PMMA which spreads the light efficiently, Color Rendering Index ≥70, Total Harmonic Distortion 10%, Driver Efficiency 85%, IP 65, PF 0.95, Surge Protection 4KV.Luminaire Performance: IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification: LM 79 & LM 80 Certificates. Min Delivered Lumens: 350(±10%) lumen, Standard Deviation Colour Matching (SDCM) 4, an operating Voltage Range of 220 - 240 V, similar to Bajaj Cat. No. BGBOS 600 5W LED or equiv. Sample luminaire and paint shall be got approved by Engineer-in- charge / consultant.

64

-

-

... More
1 Set of 320/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
(c) 25 mm nominal bore.

248

-

-

... More
NOTE FOR ALUMINIUM & GLAZING WORK Note 1:- Scope of supply includes Design, Fabrication, Supply Installation, Testing, Projection, Cleaning & Handover of respective façade system mention below,custom designed to with stand the design wind pressure confirming to IS-875 part III.The design of aluminium members to comply IS 8147-1976. The system must pass the proof test at 1.5times design wind pressure i.e. 170kg/sqm without any failure.The quote rate shall include all design, engineering drawing, fittings & fixture, Lead & Lift, all taxes,duties,statutory obligations and safety code compliance as per PMC. All material Make as per approved material List. All shade approval shall be as per architect/consultant. No procurement/work to commence on site prior to shop drawing approval from architect/consultant. Note 2:-Aluminium work Like Structural Glazing, Aluminium window & Louver , Facade of Toilet Block, work should be executed by specialized agency . The contractor shall submit 5 copies of shop drawings for Structural glazing, Aluminium Door & Window, Composite Window, Louver showing dimension details of construction etc. for approval and according to the approved shop drawing a sample of each of system with all fittings and fixture with locking arrangement including glass panes submitted for preliminary inspection for sample approval. After that the sample should be fixed at site to ascertain its performance. Large scale manufacturing should be taken up only after rectification of defects in sample as directed to the full satisfaction of the department / PMC and after obtaining formal approval of the same.( Approved Make for extrusions -Hindalco,Jindal, Satya surya Aluminium India Pvt. Ltd. )

-

-

-

... More
LIFT NO. 8 & 17 Group of 1 No. Car as per directed by Engineeer in Charge.

-

-

-

... More
g) 300 mm dia - MS 10 mm thick pipe. (Welded/Flanged Joints)

34

-

-

... More
(xvi) VFDs in suitable enclosure shall be installed near the equipments for motors of following ratings:-

-

-

-

... More
Supply, Installation, Testing & Commissioning of Bulk cables and connectors with LAN I/O ports for VC and requisite UPS power point for rack as per directed by Engineer in Incharge.

1

-

-

... More
Under Voltage & Over Voltage protection with protection release.

-

-

-

... More
Outgoing

-

-

-

... More
9. Rates shall be inclusive of all sundries whether it is mentioned in BOQ/ specification or not. Rates to be quoted for complete SITC for the purpose stated in the basis of design.

-

-

-

... More
(i) 1.50 mm

722

-

-

... More
4 Set of 800/5A CTs of 10 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
40 mm dia drain pipe

4

-

-

... More
Providing and fixing 200 mm center Guide with clamp

144

-

-

... More
(i) Dia 300 mm (8.0 mm thick)

591

-

-

... More
Total Travel distance: As mentioned below

-

-

-

... More
MAIN FEEDER PILLAR : Supply, installation, testing & commissioning of factory fabricated feeder pillar comprising of the following shall be moisture, dust & vermin proof, double door, compartmentalised suitable for floor mounting complete with aluminium bus bars, incomer with MCCB and outgoing with MCB,provisions for earthing, painting, canopy, etc. complete as required as per specifications and approved drawings. Cost of foundation to be included. Shop drawings shall be in the scope of bidder as per directed by Engineer in Charge..

-

-

-

... More
Bus Bar

-

-

-

... More
Lot, anti-vibration pads, Axially Split, Coupling, Coupling Guard, External type Mechanical Seal, Nut Bolts, Supports, Corrosion resistant finish, and all necessary accessories as required and as per specificaitons.

-

-

-

... More
Start-stop switch with key

-

-

-

... More
c) 5.5 KW - 02 No.

-

-

-

... More
1 no. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
(i) 500 A, 415V, 3ph, 4 wire Aluminium busbar

-

-

-

... More
Wrapping and coating at Outer-surface of the Pipe, black anti-corrosive bitumastic paint of approved shade and brand. of Hydrant System in Underground installation, providing (2 layers of 4mm thk. wrapping/coating treatment (as per IS:10221). All sub soil piping shall be treated as per IS code and refilling shall only be carried out after inspection and approval of the Engineer-in-Charge.

-

-

-

... More
Providing and fixing dry cladding with Red Sand stone upto 10 metre heights with 30 mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1m x 1m, fixed to structural steel frame work and/ or with the help of clamps & anchored bolt etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge.(The stainless steel Clamps and anchor bolts etc. shall be paid for separately).Red sand stone - 30mm thick gang saw cut stone

31170

-

-

... More
Supply, Installation, Testing and Commissioning of Building Automation Server software, with 10000 I/O point, unlimited concurrent users and it shall utilize the latest JAVA technologies. The software should have capability of integrating Modbus/IP, BACNET/IP, Lonworks/IP, SNMP, KNX and M-Bus/IP without any additional integration costs or software drivers as per Engineer in Charge. The system should have following features: - System Integrations - Graphical User Interfaces - Profiles and User Rights - Alarm Handling - Trends and Event Logs - Monitoring and Reporting - JS based Scripting Interface -Engineering and Commissioning Dongle/ License of the manufacturer -Email Alerts of Alarms

2

-

-

... More
(ii) 0-500 V Voltmeter with Voltmeter selector switch and control fuses - 1 Set

-

-

-

... More
VAV-05/08-2F-H 1470 441

2

-

-

... More
Supplying, Drilling/Cleaning hole and injecting of approved make Chemical complete in all respect. (Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection (As per EC2/TR 023 or relevant tested and accepted rebar guidelines.) Complete as per direction of E/I

-

-

-

... More
VAV-05-1F-G 3140 942

1

-

-

... More
Providing and fixing of Motorised Volume control dampers with actuator. Price shall be inclusive of control module, related control wiring etc. Damper shall be with TDF flanges. Actautor shall be wired over MODBUS RS485/BACnet/Open protocol. All other parameters as per the technical specifications given in the tender . As Direction of E/C

10

-

-

... More
(c) ON/OFF push button with control fuses – 1 Set

-

-

-

... More
e. All requirements of Specifications, whether such requirements are mentioned in the item or not. The Specifications and Drawings where available, are to be read as complimentary to and part of the Schedule of Quantities and any work called for in one shall be taken as required for all.

-

-

-

... More
c. Loading, transporting, unloading, handling/double handling, hoisting to all levels, setting, fitting and fixing in position, protecting, disposal of debris and all other labour necessary in and for the full and entire execution and for the job in accordance with the contract documents, good practice and recognized principles.

-

-

-

... More
4 WAY (8+12), Double door, Vertical type (Power SDB)

92

-

-

... More
FDB - LGF (FLOOR DISTRIBUTION BOARD )( SWITCH ROOM-1 ) / FDB - GF ( SWITCH ROOM-2 ) / FDB - GF ( SWITCH ROOM-3 ) / FDB-FF ( SWITCH ROOM-4 ) / FDB-SF ( SWITCH ROOM-5 ) / FDB-3F ( SWITCH ROOM-6 ) as per direction of Engineer-in-charge

12

-

-

... More
VAV-03-1F-C 6690 2007

1

-

-

... More
4 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
450 mm width x 50 mm depth x 2.0 mm thickness

10

-

-

... More
2 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
4 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
4 Nos, 250 Amps TP MCCB, 50 KA, Thermomagnetic Protection controlled.

-

-

-

... More
1 Set of 200/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
2 way Electronic pressure independent Control Valve with an equal percentage flow characteristics with modulating actuators for cooling coils of Air handling units. Valve shall be Electronic Pressure Independent control Valve that measures flow using sensors with no moving parts. Valves shall be duly insulated with same material as on pipe, PN16 rated, along with electronic modulating thermostat with digital display in square size, with necesary wirings and transformer, complete in all respect, as required and as per specification.

-

-

-

... More
2 no. 63A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
4 Strip aluminium bus bar of 300 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work,using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All Works upto plinth.

43432

-

-

... More
Outgoing

-

-

-

... More
PLC Hardware System- SIEMENS / ALLEN BRADLEY

-

-

-

... More
Dia 200mm - 9 No.

-

-

-

... More
(vii) 850 15

6

-

-

... More
(i) 76 mm Width

115

-

-

... More
TP- ACDB 01/02(N/F) : Supply, installation, testing and commissioning of following distribution boards totally enclosed compartmentalized, cubicle floor mounted, indoor type IP:42, factory fabricated with 2 mm thick sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply suitable for 25 KA as per specifications and drawings. All Air Circuit Breakers shall be provided with Micro processor based Earth fault, short circuit and over current releases. Moulded case circuit Breakers shall be microprocessor based electronic trip. Fault level for all ACB/MCCB and bus bar shall be 25 KA, all the motor feeder shall be type-2 coordinated. ICU shall be equal to ICS=100% . As Direction of E/C

4

-

-

... More
Panel Suitable for 3 Nos DG Set.

-

-

-

... More
(v) 450 mm width X 62.5 mm depth X 2.0 mm thickness

1800

-

-

... More
Voltage Lower Relay .

-

-

-

... More
(a) 300 A 4P MCCB – 1 No.

-

-

-

... More
1 No. ACB (EDO Type) microprocessor based 4P, 2500A 65 KA with O/L, S/C & E/F releases

-

-

-

... More
4 no. 32A 4P MCCB,Thermomagnetic controlled.

-

-

-

... More
PMDB-3F (POWER MAIN DISTRIBUTION BOARD) ( THIRD FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 1 as per direction of Engineer-in-charge

2

-

-

... More
Supply, Installation, Testing & Commissioning of Rack Mounted, 24 port Gigabit L2 managed PoE+ switch 375Watt with 4 SFP Uplink Port completely as per specifications as directed by Engineer in Charge.

24

-

-

... More
Unit mounted VSD panel with passive harmonic filter. Power and control cabling from panel up to motor shall be included.

-

-

-

... More
1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
2 NO Type-1 SPD with inbuilt fuse.

-

-

-

... More
Supplying and laying 50 mm X 6 mm G.I strip on surface or in recess as earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) as per directed by Engineeer in Charge (For HT And LT Panel Body Earthing )

620

-

-

... More
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-incharge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm..

637

-

-

... More
FOR EAST BLOCK Max. Setting Min. Setting

-

-

-

... More
With common burnt clay F.P.S (non modular) bricks of class designation 7.5

182

-

-

... More
Extra for Labour Charges for lowering down in foundation for Providing & Binding Reinforcement of any dia below Level +680.20.

9386

-

-

... More
(i) 0-63 Ammeter with Ammeter selector switch and 63/5 C.T.s -1 Set

-

-

-

... More
3.5 C x 95 sq mm A2XFY cable

2054.48

-

-

... More
• Power consumption: Max. 1.5 W

-

-

-

... More
All MCCB outgoings spare wired contacts for ON/OFF and Trip shall be provided for SCADA / BMS communication.

-

-

-

... More
2x62.5 kVAr LT power capacitor banks with 2 No. 50 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
Strainer :-Supply,installation,testing and commissioning of CI 86-93 Grade A, Bolted Cover, SS -304 screen, Y-Type Strainer with permanent magnet. complete with insulation & all accessories and all other parameters as per the technical specifications given in the tender. As Direction of E/C

-

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
Supplying, fitting and fixing C.P. brass Bib cock with wall flange, Cat. No. CQT - CHR - 23047 or approved equivalent} including cutting and making good the walls wherever required as per direction of Engineer In Change.

199

-

-

... More
(g) 65 mm nominal bore.

2618

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
Under Voltage Aux. Relay

-

-

-

... More
10. Rates shall be inclusive of breaking and opening of wall, chasing of wall & floor for drain and making them good including finishing and paintaing upto client satisfaction. Cost of sealing of all air gaps opening with UL/FM approved fire sealant rate for 250C for 2 hours shall also be considered.

-

-

-

... More
Supply, Installation, Testing & Commissioning of IP CCTV Network storage : The storage shall delivers total available throughput of 450 Mbps / 300 Streams for recording of IP video streams as well as playback and export through the client machine .It should have following hardware fetaure as minimum Processor Intel® Xeon E3-1276 v3 or better, Operating System Microsoft® Windows®Server 2012 . It should have 200GB SSD storage for Operating system.It should gave Internal Memory 32 GB DDR3 ECC or better with a Storage upto 96 TB or more. It should support RAID 6 feature for HDD redundancy and should be UL listed. It should have Internal, Redundant Power SupplyI, It shall support hot standby failover.Recording to be done with - 720p , 25fps -100% motion for 60days . Minimum 258 TB usable space should be provided as directed by Engineer in Charge. NOTE : 1) Vendor to share Storage calculations to be considered for the above cameras. 2) OEM of Cameras and Viedo software shall be same make.

2

-

-

... More
Incomer

-

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : For overground pipes Hydrant & Sprinkler System :-

-

-

-

... More
65 mm dia drain pipe

16

-

-

... More
Extra for using chemical for artificial treatment of soil with 20 Kgs for each earth pit as required (TERREC/TERRA GEL). The remaining space of earth pit shall be filled with agricultural soil and properly compacted. as required. as per direction of Engineer-in-charge.

100

-

-

... More
4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 25 KA fault - 1 set

-

-

-

... More
(iii) 200 A 4P MCCB - 03 No.

-

-

-

... More
(iii) 12 HP

4

-

-

... More
(d) 32 mm nominal bore.

2068

-

-

... More
(b) 5000 liter capacity (over Ac Plant) (8 Nos Tank)

80000

-

-

... More
160mm diameter UPVC. pipe

300

-

-

... More
LED EXIT SIGNAGES Supply, installation, testing and commissioning of hanging type 1W LED based EXIT signage's including with legend on both sides, nickel metal hydride battery having 3 hours duration complete as required as per approved make & direction of Engineer-in-charge.

-

-

-

... More
Fan should be AMCA certified for air and sound performance.

-

-

-

... More
Size - 1000X600

152

-

-

... More
Extended piping kit complete with check valves, solenoid valves, "U" trap, additional oil charge cabling etc. as required

-

-

-

... More
Supply, Installation, Testing & Commissioning of 15Mtrs HDMI Cable : Crystal-clear video up to 4K DCI (4096 x 2160 @ 30Hz), 4K UHD (3840 x 2160 @ 30Hz), and 1080p @ 60Hz signal HDMI Ethernet Channel functionality: additional dedicated data channel supports networking HDMI (3D, Deep Color, 4K) and HDCP 2.2 compatible Gold-plated connectors for reliable transmissions 15 mtrs in Length, RoHS-compliant as per directed by Engineer in Charge

1

-

-

... More
5 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
6 no. 40A 4P MCCB, 25 KA Thermomagnetic controlled.

-

-

-

... More
3 Nos. ACB (EDO Type) microprocessor based 4P, 4000A 65 KA with O/L, S/C & E/F releases

-

-

-

... More
Pilot Light Amber 230v AC(DC Failure) - LED type - 1 No.

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
Supplying, installation, testing & commissioning of addressable phone control module complete as required.

172

-

-

... More
7 no. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
1 Set of 250/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
SITC of GI Strip for Down Conductor to earth (25x6 mm), as specified in drawing and confirming to IS/IEC 62305 as per direction of Engineer-in-charge.

840

-

-

... More
Supply, Installation, Testing & Commissioning of 4.0M GI Pole for Driver Camera as per technical specification. Civil works for Pole shall be in the scope of bidder. -1no.

-

-

-

... More
Supplying, fitting and fixing C.P.on brass Hand shower (Health faucet) with 8 mm dia, 1.2 metre long Flexible tube with wall hook, (Jaquar, Allied, Cat.No. ALD - CHR - 573 or approved equivalent) as per direction of Engineer In Change.

595

-

-

... More
2 no. 800A 4P EDO ACB, 25 KA microprocessor controlled with overload, short circuit and earth fault protections with adjustable settings with E/M Interlocking.

-

-

-

... More
Providing & Fixing Tower Bolt SS 304 18" Long with SSS finish for Aluminium Door Shutter with necessary screw etc. complete in all respect and instructions of the Engineer in charge .

119

-

-

... More
1 Set of 320/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
TOILET SIGNAGE (Ladies)

90

-

-

... More
32 mm nominal outer dia .Pipes.

1418

-

-

... More
1 Set of R, Y, B phase indicating light (LED type) with 2A , SP MCB, 10KA

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, including horizontal and vertical bends, reducers, tees, cross members and other accessories as required etc as per directed by Engineer in Charge.

-

-

-

... More
h). CLIP facility for all ordered extension & trunk,

-

-

-

... More
2 Sets of 400 A 4P MCCBs 50 KA miroroprocessor based controlled with overload, short circuit and earth fault protections.

-

-

-

... More
VAV-01-1F-A 3680 1104

1

-

-

... More
All MCCBs with Microprocessor release should have adjustable O/L, S/C & inbuilt E/F protections

-

-

-

... More
(c) ON/OFF push button with control fuses – 1 Set

-

-

-

... More
4 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
2 Nos. 100 Amps TP MCCB,50 KA, Thermomagnetic Protection controlled.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Dual Channel Digital Power amplifier, 2 x 120Watts @ 100V / 4Ω; Bridgeable to 1 X 240Watts @ 100V / 8 Ω; Power Amp Topology : Class D; PSU Technology : SMPS; Convection cooled; Power Supply : SMPS; Output Voltage Taps : 100V - 70V - 50V - 35V - 4Ω; Protection Circuit : Over Current, Over temperature, DC Offset; Frequency response : 50 - 20KHz; S/N ratio : 98 dB A-Wieghted; THD: 0.1% @ 1KHz A Wieghted ; Power Consumption 300W; 1U 19" rackmount as per directed by Engineer in Charge.

1

-

-

... More
(g) 80 mm nominal bore.

2

-

-

... More
1000 amps 50KA SC for 1 sec

76

-

-

... More
3C x 6 Sq mm for Fuel transfer pump

320

-

-

... More
SITC of GI Strip holder (25x6 mm), as specified in drawing and confirming to IS/IEC 62305 as per direction of Engineer-in-charge.

336

-

-

... More
Speed Raise Relay .

-

-

-

... More
(ii) 400 mm dia ≤ 1400 RPM, Sound level should not exceed 55 dB(A) at 3m

20

-

-

... More
Providing & fixing Vision panel of 6mm thick borosilicate Fire Rated clear glass of size 450mm (W) x 900mm (H), Self adhesive side roll (Ceramic Tape) as required (For Fire Metal Door)

174

-

-

... More
VAV-03-GF-E 1966 590

1

-

-

... More
Bus Bar

-

-

-

... More
5 no. 63A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
5 no. 32A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Waterproofing of Roof or Open terrace Providing and laying water proofing treatment on roofs of slabs consisting of following :-(-(Measurement on treated floor area only treatment over Parapet wall is included in this Rate. Following all items included in this Rate except mentioned) 1.Surface Preparation:-Cleaning the surface to make it dust free and sludge free, removing any extended portions by grinding and if required using suitable equipment. The mother slab has to be laid in slope to ensure proper drainage through the drain openings. All surfaces to be waterproofed should be sound, clean and dry. Concrete surfaces should have a light steel-trowel followed by a fine hair-broom or equivalent finish which is dry and free of dust, oil and other contaminants. All high spots should be removed. 2.Crack treatment & Coving :- Cracks if any shall be cut open and shall be filled with appropriate product by Opening the cracks to V grooves and treat them with suitable product ( Top 77/ Nitobond SBR Latex/ Master emaco SBR2) of approved manufacturer . Coving the junctions of the Vertical wall and Roof slab with fillet of size 75mm x 75mm with Cement Sand mortar 1: 3 admixed with waterproofing compound of approved manufacturer & their direction. 3.Application of primer:- Application of suitable primer (Sikalastic 450H/ Nitoproff / Master Seal P 2525) on the prepared surface to seal the pores as per manufacturer's specification. 4.Water proofing product:-Supply and apply appropriate membrane product of minimum thickness 2mm (Sikalastic 560/Fosroc Nito proof 600/BASF Master Seal M800)by applying in roof slab & Parapet Wall upto 450 mm as per approved manufacturer specification. 5. Application of cover:- Supply & application of 150gsm geotextile cloth 2 Layer 1) over the fully cured waterproofing membrane & 2)overpolyethelen film and proper fixing arrangement.(Paid in separate item) As per direction of Engineer in Charge

-

-

-

... More
5 no. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
All incoming Breaker Shall have bus duct entry from top.

-

-

-

... More
Incoming

-

-

-

... More
(ii) 110 mm diameter.

232

-

-

... More
(c) ON/OFF push button with control fuses – 1 Set

-

-

-

... More
(i) 0-63 Ammeter with Ammeter selector switch and 63/5 C.T.s -1 Set

-

-

-

... More
(xviii) AH-1F-03 31 29300 4

1

-

-

... More
(x) 0-16 A Ammeter with ammeter selector switch & 16/5 CT's - 06 Sets.

-

-

-

... More
Providing and fixing inspectors test assembly complete with test valve, sight glass sectional drain valve, union with corrosion resistant orifice all complete strictly include with tender BOQ. Note:Test assembly with test valve, sight glass sectional drain valve, union with corrosion resistant orifice all complete work should be executed by specialized agency. The agency/contractor shall submit of shop drawings for Test assembly details of construction etc. for approval and according to the approved shop drawing a sample of each of system submitted for preliminary inspection for sample approval. After that the sample should be fixed at site to ascertain its performance. Large scale manufacturing should be taken up only after rectification of defects in sample as directed to the full satisfaction of the department / PMC and after obtaining formal approval of the same .as per direction of Engineer in Charge. 50 mm dia

106

-

-

... More
2 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
(v) 34680 CMH at SP at 20 mm WG

4

-

-

... More
b) 7.5 KW - 02 No.

-

-

-

... More
Bus Bar

-

-

-

... More
Supplying, installation, testing & commissioning of 75 watt RGB wallwasher Light, Protection : IP65 Class 1, Input Voltage : 220V AC, Operating Voltage : 24V DC, Power Consumption : 75 watt, Beam Angle : 10 deg, Control Mode : DMX, Housing : Aluminium Alloy, Operating Temp : -20 to 50 deg, 3 pin XLR input/output,

360

-

-

... More
Supplying, installation, testing & commissioning of 3 Mtr MM LC to LC Optical Patch Cord, 50/125 Micron, (OM4) as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

436

-

-

... More
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre

8531

-

-

... More
Fan assembly shall be statically and dynamically balanced to G 2.5 grade as per ISO 1940.

-

-

-

... More
MANUAL/AUTO Switch - 1 No.

-

-

-

... More
Safety stud anchor M10x110/30

4

-

-

... More
e) 200 mm dia

64

-

-

... More
Putty Trowel finish:-Providing & laying 12mm thick trowel finish White cement base Putty of apprved make(Birla White, J K & Berger) on interior wall on specified area as per drawing complete in all respect as per direction of Engineer in Incharge ay any level.

2364

-

-

... More
Providing and fixing class-O Kaiflex ST / Thermaflex or other approved make tube insulation of 6mm thick insulation to hot water pipe and fittings and valves as per manufacturer's recommendations complete as per direction of Engineer-in-charge.

-

-

-

... More
SITC of Al Round Conductor Holder for Flat Roof,according to IS/IEC 62305 as per direction of Engineer-in-charge

300

-

-

... More
(e) 40 mm dia pipe

1400

-

-

... More
Supply, Installation, Testing & Commissioning of Microprocessor based networkable analogue expandable type addressable type sub fire alarm panel with suitable loop card and amplifier wattage . Each loop card and amplifer should have 20% spare capacity for future provision. Panel should have min. 640 character LCD display. The panel shall have access levels, capable of record upto 1000 event log history, sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump. Panel should operate with 240 volts AC power supply, automatic battery charger of suitable capacity , 24volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 min during an emergency conditions as required. The panel should have port to connect online printer.System is capabale of generate alarm condition if central processing unit fails. The network shall support min 64 panels / nodes per network.(UL 9th or latest Edition Approved and FM approved). Mounting accessories of main fire panel, electrical connectivity from nearest DB, civil works, excavation route and connectivity from main fire panel to under ground parking shall be in the scope of bidder.(SUB FIRE ALARM PANEL IN UNDER GROUND PARKING) as per directed by Engineer in Charge.

2

-

-

... More
Circular Tank

18000

-

-

... More
20 mm nominal outer dia .Pipes.

109

-

-

... More
a) 11 KW - 02 No.

-

-

-

... More
(Note for WTP :The following description of Items shall be read in conjunction with the technical tender specifications and schematic drawings,. Work will be executed as per the shop drawing to be prepared by the specialized agency /Nominated contractor and to be approved by the owner/consultant. The Water Treatment Plant to be placed in the pump room beside under ground reservoir. Pump Room and UGR to be constructed by other agency.

-

-

-

... More
1 no. 150A 4P MCCB, 25 KA Thermomagnetic controlled. with overload, short circuit and earth fault protections with adjustable settings.

-

-

-

... More
9 no. 63A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood 50 x 20 mm

15254

-

-

... More
(c) 150 mm nominal bore.

1706

-

-

... More
Supply and fixing C.I cover with frame for manhole 560mm diameter C.I cover (heavy duty) the weight of the cover to be not less than 108 kg.

360

-

-

... More
Transformer REF Relay to control HT breaker during earth fault for resective breaker for respective transformer.

-

-

-

... More
Supply and making end termination with double brass compression glands and aluminium lugs for following size of XLPE insulated and PVC sheathed/ aluminium conductor cable of 1.1 kv grade as required.

-

-

-

... More
(viii) 9.5 mm

474

-

-

... More
2 nos. 40A DP MCCB Thermomagnetic controlled.

-

-

-

... More
VAV-08-2F-D 2380 714

1

-

-

... More
Supplying, installation, testing & commissioning of CAT6A Keystone Jack, T568 A/B Wiring for Data as per specification (ANSI/TIA Standard) as per directed by Engineer in Charge

7380

-

-

... More
Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373

-

-

-

... More
75 mm dia

4564

-

-

... More
DDC- 23

2

-

-

... More
(iv) 32640 CMH at SP at 20 mm WG

8

-

-

... More
4000 A, 415V, 4 strip, 50 KA, 50 Hz Aluminium Bus bar

-

-

-

... More
• Microprocessor –controlled, single channel loop detector

-

-

-

... More
4 no. 32A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Providing and laying Double charge Vitrified tiles in different sizes in skirting (thickness to be specified by manufacturer), with water absorption less than 0.08 % , of approved make , in approved design & colour, in dado, skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete with all lead & lift as specified and as directed by Engineer-in-charge.

-

-

-

... More
b). IP Extension: 47 nos.

-

-

-

... More
Supply, assembly and  laying of under floor trunking  made out of 1.5mm thick GI sheet  complete with Coupler,Fixing bracket,risers, Junction box, floor box etc.  complete with all other accessories under floor installation including cutting and chasing the floor/ or on surface, making good the same, placing in position and cleaning from inside complete etc. as required. as per direction of Engineer-in-charge.

-

-

-

... More
(ii) Dia 200mm - (8.0 mm thick)

1276

-

-

... More
1 Set of 150/5A CTs of 5 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
VAV-07-3F-B 2095 629

1

-

-

... More
SITC of 230V single phase, 400mm Hi -Speed wall bracket fans with fixing accessories as required.(FAN AND EXHAUST FAN)

48

-

-

... More
VAV-08-GF-D 1738 521

1

-

-

... More
40 amps, TPN

278

-

-

... More
a) 17000 CMH at SP at 20 mm WG ( Minimum Efficiency - 62%)

32

-

-

... More
VAV-02-1F-H 3505 1052

1

-

-

... More
Incomer

-

-

-

... More
Set of phase indicating lamp (LED Type) with 2A,SP MCB - 1 set.

-

-

-

... More
(vii) Dia 65mm

283

-

-

... More
100mm dia. nominal inner dia.

330

-

-

... More
DDC- 4

2

-

-

... More
(ii) 25 mm Dia

65

-

-

... More
Design, supply fabricate and fixing Aluminium Screen Perforated façade consists of flat aluminium alloy AA3005/305 as per drawing & design at any Level as per direction of the Engineer in Charge with necessary MS Supported sub structure.

3740

-

-

... More
VAV-10-GF-D 1808 542

1

-

-

... More
(viii) 0-40 A Ammeter with Ammeter selector switch & 40/5 C.T.s - 02 Sets

-

-

-

... More
LMDB-GF (LIGHTING MAIN DISTRIBUTION BOARD) ( GROUND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 1 as per direction of Engineer-in-charge.

2

-

-

... More
VAV-02-GF-E 3468 1040

1

-

-

... More
6 no. 40A DP MCCB, Thermomagnetic controlled.

-

-

-

... More
Outgoing

-

-

-

... More
150 mm width x 40 mm depth x 1.6 mm thickness

2400

-

-

... More
Bus Bar

-

-

-

... More
Number of Floors: As mentioned below

-

-

-

... More
Single mode 2 core Fibre optic cable, Zero Halogen Low Smoke outer Sheath, with Required Junction Boxes,Connectors and jointing accessories wherever required And also with required Converters from Cat 6E to Fibre and Fiber to Cat 6E terminations as required with Cable tie`s & Tags as per directed by Engineer in Charge.

2000

-

-

... More
65mm dia

2000

-

-

... More
(x) 21300

1

-

-

... More
1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

-

-

-

... More
50 mm dia

264

-

-

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump : capacity 2850 lpm at 70 m head) (a) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (c) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads.

4

-

-

... More
Supply and making of End termination material as per directed by Engineer in Charge

-

-

-

... More
(v) 16 A TP MPCB - 06 No.

-

-

-

... More
Shunt trip coil. - 2 Sets

-

-

-

... More
TOILET SIGNAGE (Gents)

90

-

-

... More
2x12.5 kVAr LT power capacitor banks with 1 No. 10 kVAr 7% D tuned harmonic block reactor and TSM (Thyristor Switch Module) mounted in sheet steel enclosure with High Speed Fuses ( Semi Conductor Fuses of 690 VAC)

-

-

-

... More
Labour for chipping of any concrete (Beam,Wall, Lintel Chajja, Slab Column & any other Conc. Surface) surface before taking up plastering work as per instruction of Engineer-in-charges.

564745

-

-

... More
DDC- 41

2

-

-

... More
SIDE STREAM FILTERATION SYSTEM Supply installation testing and commissioning side stream fileteration sytem for flow of 45 cmh with inlet & outlet of required size as per manufactureres recommendation with motorized butterfly valves for equal runs, control panel as required and as per specification. As Direction of E/C

2

-

-

... More
5000 A, 415V, 3-phase, TPN, 65 KA, 50 Hz Aluminium Bus bar

-

-

-

... More
4 C x 10 sq mm A2XFY cable

17761.14

-

-

... More
Cooling capacity at designed ambient conditions.

-

-

-

... More
Providing and fixing thermal insulation with Resin Bonded Rock wool conforming to IS: 8183 having density 48 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge.

41834

-

-

... More
Supplying, installation, testing & commissioning of cubical type LT panel suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized as per IS13947-1,2,3, IEC-60439, IEC-60947-1/2,IEC 61439-1/2,IEC 60529,IEC 62262,IEC61641 design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. zero halogen fire retardant insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears.(General arrangement and schematic drawings to be prepare by bidder and same shall be got approved by the E.I.C. before start of fabrication) as per directed by Engineeer in Charge.

-

-

-

... More
Upto 35 sq. mm

14882

-

-

... More
VAV-08-GF-A 1900 570

1

-

-

... More
Custom clearance, inland transport up to site, lifting, shifting & installation on Ground Floor Level at Service Block

-

-

-

... More
ACSDB-01 (F) Supply, installation, testing and commissioning of following distribution boards totally enclosed compartmentalized, cubicle floor mounted, indoor type IP:42, factory fabricated with 2 mm thick sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply suitable for 25 KA as per specifications and drawings. All Air Circuit Breakers shall be provided with Micro processor based Earth fault, short circuit and over current releases. Moulded case circuit Breakers shall be microprocessor based electronic trip. Fault level for all ACB/MCCB and bus bar shall be 25 KA, all the motor feeder shall be type-2 coordinated. ICU shall be equal to ICS=100%. As Direction of E/C

2

-

-

... More
VAV-05-GF-H 3530 1059

1

-

-

... More
4 nos. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Outgoing

-

-

-

... More
DWC HDPE PIPE Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.

-

-

-

... More
LMDB-GF (LIGHTING MAIN DISTRIBUTION BOARD) ( GROUND FLOOR - EAST & WEST BLOCK) ELECTRICAL ROOM 2 as per direction of Engineer-in-charge.

2

-

-

... More
l). Boss/Secretary feature

-

-

-

... More
Supply, Installation, Testing & Commissioning of Patch cord CAT-6A UTP, TIA / EIA 568-C.2, 2mt as directed by Engineer in Charge.

60

-

-

... More
Supplying, installation, testing & commissioning of following sizes of stainless steel belllows for exhaust system as per directed by Engineeer in Charge.

-

-

-

... More
8 WAY (8+24), Double door, Vertical type (Lighting SDB)

32

-

-

... More
NOTE FOR WATER PROOFING WORK:- a) The contractor shall get written approval from the Engineer- in- charge, for the water proofing agency from approved manufacturer as engaged their sound applicator/own and shall submit the specification & Applicator credential for taking approval of the waterproofing agency before commencement of the work complete in all respect as per the directions of Engineer-in-Charge. b) The contractor shall furnish guarantee bond on appropriate stamp paper for the entire waterproofing treatment for maintaining the surroundings and under side surfaces of the waterproofing treated area in bone dry condition for 10 years. During the guarantee period the contractor shall attend all leakages, defects etc. if noticed, free of cost, starting the work of checking up and rectification within a week's time from the date of intimation about such leakages/defects. c) The contractor shall test the surface where water proofing treatment provided for bone dry condition by filling up with water. No wet patches or leaks shall appear on the surrounding wall or under side of the slab. d) The Contractor shall keep the water proof area filled with water after the water proofing work has been completed for testing of leakage and shall clean it before handing over. Faulty area shall again be done, before handing over the , if found necessary by the Engineer- in-charge.

-

-

-

... More
(ii) 1.2 TR

40

-

-

... More
DC Failure Relay

-

-

-

... More
Pumping for work from discharge of submersible pump onwards: This work is generally to be done by plumbing contractor, however this work to be done by Tube well contractor on specific instruction of site-in-charge as per site requirement as per direction of Engineer-in-charge. (a) Supplying, fitting and fixing 100 mm dia G.I. pipe line (Tata heavy quality) with all fittings from discharge end of Submersible Pump to nearby Water Tank for over ground or underground installation including necessary earthwork, clamps including two coats painting.

300

-

-

... More
1 Set of 1000/5A CTs of 15 VA burden, accuracy Class-0.5 for metering and class 5P10 for protection with digital multifunction meter.

-

-

-

... More
Supply, installation, testing, balancing and commissioning of continuous linear powder coated extruded aluminium Supply air grilles with Al. volume control dampers of various sizes complete as per specifications.

136

-

-

... More
FIRE RATED DOOR :- Providing and fixing of factory made Hollow metal fire rated doors as per IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI or ARAI or BFRC for maximum rating of 2hrs with vision panel. Test certificates should be available for vision lites /panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied should be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory as per direction of Engineer in Charge. Frame-Fire Door frame 2hrs FIRE RATED shall be double rebate profile of size 143 x 57 mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be Mitered and field assembled with self tabs. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the striking jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for fire doors on the clear masonry opening.

1306

-

-

... More
150mm dia. nominal inner dia.

5374

-

-

... More
(b) 80 mm dia pipe

200

-

-

... More
VAV-06-1F-A 1225 368

1

-

-

... More
(i) 340 10

20

-

-

... More
5 no. 40A 4P MCCB, Thermomagnetic controlled.

-

-

-

... More
Supply, installation, testing and commissioning of monorail hoist with chain pulley block and travelling trolley as per IS 3832 and including endless short link/round link chains as per IS 6216 / 2429, point hook with shank as per IS 8610/3815,load chains grade 40 IS 3109,hand chain grade 30, IS 3109 as per tender / codal specification as required all complete as directed by Engineer in Charge. Capacity – 2 Ton, Lift - 4 metre.

20

-

-

... More
UMDB (UPS MAIN DISTRIBUTION BOARD ) ( SERVER ROOM ) as per direction of Engineer-in-charge

2

-

-

... More
Incoming

-

-

-

... More
3.5C x 50 Sqmm for Incomer supply

60

-

-

... More
Providing and fixing Pre approved Granite stone slab 18mm thick semi polished in trader of steps with single piece & Landing of steps with single piece over 22mm thick base of cement mortar 1 : 4 (1 cement : 4 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete with Single piece all lead & lift as specified and as directed by Engineer-in-charge. * Provision for Stair case railing baseplate square hole should be maintained.

7708

-

-

... More
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilizing the equipment's, paying all changes and fees, testing etc. and submission of test reports for parameters as per IS:10500, complete in all respect as per direction of Engineer-in-charge. a) Final test after completion of development of yield

2

-

-

... More
Providing & fixing MS cabinet (to enclose above FB connection) fabricated from 16 gauge MS sheet with full front glass door and locking arrangement duly painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and suitably mounted on a raised masonry platform as required (Approx 0.6m x 0.6m x 0.45m). as per direction of Engineer in Charge.

44

-

-

... More
VAV-10-1F-A/VAV-06-2F-D 1555 467

2

-

-

... More
(b) 20 mm nominal bore.

56

-

-

... More
Magnetic type Flow meter with transmitter for measuring flow suitable to mount on chilled water pipe --Line Size 50 mm (For Make up Water)

-

-

-

... More
Supply, Installation, Testing and Commissioning of LED Surface mounted Luminaire with a nomial system lumen output of 2900(±5%) lumens and a minimum system efficacy of 90lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a CCT 5700k or 6500k, CRI 80, PF 0.95, an operating Voltage Range of 220V- 240V, Standard Deviation Colour Matching (SDCM) =3 to =5. . The luminaire shall meet IP20 rating with THD20% and PF 0.9. The total Power Consumption should be within 30W to 36W(including driver). Similar to Philips Make SmartBright Surface "SM270 LED30 6500 PSU OD GR" or eqiv. All test should be done as per IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification Required: LM 79 & LM 80 . Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.

954

-

-

... More
Supplying, installing, testing and commissioning of ceiling loudspeaker of minimum 4.25 inch driver and a 1 inch tweeter in a 2-way design with polypropylene woofer material and an IP rating of IP50, transformer with multiple taps of at least 30 - 15 - 7.5 - 3.75 watts at 100v and 30 - 15 - 7.5 - 3.75 - 1.75 watts at 70v, frequency response of at least 75 - 20KHz, dynamic power of at least 80 watts and the low impedance connection shall present a load of 16 ohms to the amplifier. The output SPL at 1m 1watt shall be at least 88 dB and maximum output SPL at 1m with full power shall be at least 108 dB. The loudspeaker shall include overload protection for failsafe operation as per directed by Engineer in Charge. .

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.