Shri Mata Vaishno Devi University Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Shri Mata Vaishno Devi University - SMVDU Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date29 May 2024
Closing Date24 Jun 2024
Tender Amount₹ 49,63,67,379 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material :

-

-

-

... More
All kinds of soil :

112

10052

89.75

... More
Filling available excavated earth (excluding rock) in trenches, plinth, foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited sides of layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.

266

58094

218.4

... More
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil.

20

48240

2412

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL antitermite treatment

-

-

-

... More
Along the external wall below concrete or masonry apron using chemical emulsion (Chloropyriphos / Lindane E.C. 20% with 1% concentration) @ 2.25 litres/ linear meter including drilling & plugging holes etc

400

16640

41.6

... More
Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. (1 kg of water proofing material in 50 kg of cement)

300

18900

63

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:

-

-

-

... More
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

50

260145

5202.9

... More
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

91

599803

6591.25

... More
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

120

688032

5733.6

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto/above plinth level

-

-

-

... More
Thermo-Mechanically Treated bars of grade Fe-500D or more.

74187

9139838

123.2

... More
Providing and filling in position bitumen mix filler of Proportion 80 kg of hot bitumen, 1 kg of cement and 0.25 cubic meter of coarse sand for expansion joints.

3

95230

31743.5

... More
Add for plaster drip course/grooves in plastered surface or moulding to R.C.C. projections

1000

62000

62

... More
CAST-IN-SITU Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level

-

-

-

... More
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

209

1627775

7788.4

... More
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement

-

-

-

... More
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

227.56

2138108

9395.7

... More
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical location in load application areas that accommodates multi directional seismic movement without stress to its components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self centering arrangement that freely rotates / moves in all directions. The Self –centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer-in-Charge. (Material shall confirm to ASTM 6063.)

-

-

-

... More
Floor joint of 100 mm gap

200

1350340

6751.7

... More
Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221-02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multi-cellular to facilitate movement. (Material shall confirm to ASTM 6063.)

-

-

-

... More
Wall joint of 100 mm gap

350

2075097

5928.85

... More
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arrangement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s preengineered self-centering arrangement that freely rotates/ moves in all directions. The self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint system shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint system to have water tight joint is mandatory requirement. Material shall confirm to ASTM 6063

-

-

-

... More
Roof joint of 100 mm gap

219

1420017

6484.1

... More
Centering and shuttering including strutting, propping etc. and removal of form for:

-

-

-

... More
Foundations, footings, bases of columns etc. for mass concrete.

150

42952

286.35

... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

450

283027

628.95

... More
Suspended floors, roofs, landings, balconies and access platforms.

500

359100

718.2

... More
Lintel, beams, plinth beams, girders, bressumers and cantilevers.

2000

1155100

577.55

... More
Columns, pillars, piers, abutments, posts and struts.

93

69057

742.55

... More
Stairs (excluding landings) except spiral staircases

50

42557

851.15

... More
Edges of slabs and breaks in floors and walls 5.9.16.1 Under 20 cm wide

500

131100

262.2

... More
Weather shades, chajjas, corbels etc. including edges

50

51867

1037.35

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and de-centering at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured). 5.11.1 Suspended floors, roofs, landings, beams and balconies (plan area to be measured)

400

117560

293.9

... More
Brick work with common burnt clay (non-modular) bricks of class designation 75

-

-

-

... More
Cement mortar 1:6 ( 1 cement : 6 coarse sand)

296

2241178

7571.55

... More
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level

296

430872

1455.65

... More
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in :

-

-

-

... More
Cement mortar 1:4 ( 1 cement : 4 coarse sand)

879

832632

947.25

... More
Extra for half Brick masonry in superstructure above plinth level upto floor V level.

879

140332

159.65

... More
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry.

879

111237

126.55

... More
Making plinth protection with common burnt clay bricks of class designation 7.5 laid on edge in cement mortar 1:6 (1 cement : 6 coarse sand) with 12 mm thick bed of cement mortar 1:6 (1 cement : 6 coarse sand) over 75 mm bed of dry brick aggregate 40mm nominal size rammed, consolidated and grouted with fine sand. The top of bricks pointed with cement mortar 1:3 (1cement: 3 fine sand) and curing complete.

350

486657

1390.45

... More
Brick edging 7cm wide 11.4cm deep to plinth protection with common burnt clay (nonmodular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1Cement : 4 fine sand) and curing complete.

450

29812

66.25

... More
Providing and laying autoclaved aerated cement blocks masonrywith150mm/230mm/300 mm thick AAC blocks in super structure above plinth level upto floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge.(200MM THICK+100MMTHICK QTY)

2324

15962626

6868.6

... More
Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, stairs, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels

-

-

-

... More
Granite of any colour or shade

-

-

-

... More
(Area of slab upto 0.5 sqm) 16 mm

104

473236

4550.35

... More
(Area of slab over 0.5 sqm) 16 mm

74

221600

2994.6

... More
Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.

220.8

84279

381.7

... More
Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite / stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete kitchen

147

114439

778.5

... More
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and finished smooth.

-

-

-

... More
Granite Stone of approved shade (18mm)

36

133142

3698.4

... More
CERAMIC GLAZED TILES Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

6611

8125580

1229.1

... More
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters

-

-

-

... More
With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws (35 mm)

1525

4932155

3234.2

... More
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured)

1525

612135

401.4

... More
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :

-

-

-

... More
25 mm dia

100

53435

534.35

... More
Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws etc. complete.

-

-

-

... More
250 mm weighing not less than 280 gms.

100

14995

149.95

... More
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :

-

-

-

... More
300x10 mm

708

87898

124.15

... More
150x10 mm

1103

92431

83.8

... More
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete

-

-

-

... More
150 mm

1150

86250

75

... More
100 mm

244

14640

60

... More
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete

-

-

-

... More
300x16 mm

386

115317

298.75

... More
250x16 mm

244

6331

25.95

... More
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete

564

81046

143.7

... More
Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete :

575

936100

1628

... More
Providing and fixing chromium plated brass casement window fastener with necessary screws etc. complete. :

1495

212140

141.9

... More
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete

-

-

-

... More
Welded

2000

276400

138.2

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete

-

-

-

... More
Hot finished welded type tubes

17440

2737208

156.95

... More
Providing and fixing circular/hexagonal cast iron box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamps shall be made of 12mm dia M.S. bar bent to shape as per standard drawing.

30

6229

207.65

... More
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.

500

48000

96

... More
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.

-

-

-

... More
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete

2826

399596

141.4

... More
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

10800

1961280

181.6

... More
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

3000

2261250

753.75

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.

-

-

-

... More
Using M.S. angles 40x40x6mm for diagonal braces

7

38457

5493.9

... More
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc.

-

-

-

... More
50mm thick with 20 mm nominal size stone aggregate.

270

151780

562.15

... More
Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) :

21613

40886392

1891.75

... More
Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, mirror polishing and curing complete

3242

7087984

2186.3

... More
MARBLE STONE FLOORING Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including rubbing, mirror polishing and curing complete with:

-

-

-

... More
Raj Nagar plain (18mm)

2401

5431302

2262.1

... More
Extra for pre finished nosing to treads of steps of marble stone

2912

1612374

553.7

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.68.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent

1021

2385515

2336.45

... More
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS:15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.

1645

1822084

1107.65

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete

-

-

-

... More
Size of tile 600x600 mm In colour such as White, Ivory, Grey,Fume Red Brown

200

279020

1395.1

... More
Providing and laying Vitrified tiles(double charge) in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades,in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete.

-

-

-

... More
Size of tile 600x600 mm

50

72445

1448.9

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete

35

9201

262.9

... More
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.

-

-

-

... More
(i) Single socketed pipes 160MM DIA PIPE

605

523930

866

... More
Providing and fixing multiwall polycarbonate sheets 12mm thick. The Sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with Aluminium profile base, EPDM seal, complete upto any piitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trussess and including cutting to size and shape wherever requried.

436

749048

1718

... More
Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion

-

-

-

... More
Bend 87.5°

-

-

-

... More
160MM DIA

70

14980

214

... More
Provinding and fixing expansion hold fasteners on C.C./R.C.C/Brick. Wedge expansion type

-

-

-

... More
Fastener with threaded dia 12mm

6272

332416

53

... More
Providing and fixing under counter wash basin with , 15 mm dia CP Brass single hole basin mixer of quality and make as approved by the Engineer-in-Charge.

-

-

-

... More
White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer

147

758622

5160.7

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.

35

2406

68.75

... More
CEMENT PLASTER (IN FINE SAND) 12mm Cement plaster of mix:

-

-

-

... More
1 : 6 ( 1 cement : 6 fine sand)

36340

9673708

266.2

... More
15mm Cement plaster on the rough side of single or half brick wall of mix:

-

-

-

... More
1 : 6 ( 1 cement : 6 fine sand)

1979

607256

306.85

... More
18mm Cement plaster in two coats under layer 12mm thick cement plaster 1 : 5 (1 cement : 5 coarse sand) finished with a top layer 6mm thick cement plaster 1 : 3 (1 cement : 3 coarse sand) finished rough with sponge

12594

5398418

428.65

... More
6MM CEMENT PLASTER 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)

27910

6733287

241.25

... More
Extra for plastering exterior walls of the height more than 10m from ground level for every additional height of 3m or part thereof.

8800

629640

71.55

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer

66229

10901293

164.6

... More
Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @2.20kg/10sqm)

12594

2300923

182.7

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.

-

-

-

... More
Two or more coats on new work

794

104688

131.85

... More
Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge :

-

-

-

... More
15 mm wide and 15 mm deep groove

15000

942000

62.8

... More
Providing and applying white cement based putty of specified thickness,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.( 2 mm thick )

50913

9217798

181.05

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with wate(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed Slurry.

2295

1113304

485.1

... More
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineerin-charge.

-

-

-

... More
With average thickness of 120mm and minimum thickness at khurra as 65 mm

4665

6552692

1404.65

... More
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. 31.28.1 Upto and including 12mm dia

300

34185

113.95

... More
Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge

-

-

-

... More
with semi perforated 12mm thick micro tegular edged GRG false ceiling

7125

13174837

1849.1

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge.

-

-

-

... More
80 mm thick C.C. paver block of M-30 grade with approved color design and pattern

500

464925

929.85

... More
RAIN WATER HARVESTING Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts,wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres.

-

-

-

... More
All kinds of soil

142

36472

256.85

... More
Supplying, filling, spreading and leveling stone boulders of size range 5 cm to 20 cm, in recharge pit in the required thickness for all leads and lifts all complete as per direction of Engineer-in-charge

36

30862

857.3

... More
Supplying, fllting, spreading and leveling gravels of size range 5 mm to 10 mm, in recharge pit over the existing layer of boulders, in the required thickness for all leads and lifts all complete as per direction of Engineer in-charge.

36

37123

1031.2

... More
Supplying, filling , spreading and leveling coarse sand of size range 1.5 mm to 2 mm, in recharge pit in required thickness over the gravel layer, for all leads and lifts all complete as per direction of Engineer-in-charge.

10

10312

1031.2

... More
Providing 600 x600 mm perforated RCC manhole covers of M-25 grade cement concrete for RCC work

60

60000

1000

... More
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :

-

-

-

... More
Cement mortar 1:4 ( 1 cement : 4 coarse sand)

20

157548

7877.4

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:

-

-

-

... More
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

3

15608

5202.9

... More
20 Passenger Lifts

-

-

-

... More
Supply, Installation, Testing & Commissioning of 20 Passanger Lift without machine room lift having contract speed of 1.5 Meter per second serving different floors in the lift shaft of size 2550x2400 as per detailed specifications and as under complete with all the equipment and accessories.

-

-

-

... More
Speed - 1.5 Meter per second

-

-

-

... More
Floors - Basement+Ground+1st to 4th Floor

-

-

-

... More
Travel - 25.75 Meter (approx.)

-

-

-

... More
Stop & Opening - 6 Stop & 6 Opening (all opening be on same side)

-

-

-

... More
Controller- A.C. variable voltage and variable frequency.

-

-

-

... More
Automatic Rescue Device (ARD) compete with dry maintenance free batteries as required.

-

-

-

... More
Operation - Microprocessor based duplex collective selective - (with/without -attendant)

-

-

-

... More
Power: 415 Volts+10%, 3 Phase 4 wire 50 Hz AC system.

-

-

-

... More
Car Enclosure: Stainless steel scratch proof (Moon Rock/ Honeycomb/ Hairline Finish) on all sides.

-

-

-

... More
Type of Doors:

-

-

-

... More
Car: Power operated, central opening, horizontal sliding stainless steel scratch proof (Moon Rock/ Honeycomb/ Hairline Finish)

-

-

-

... More
Landing doors: Power operated, central opening, horizontal sliding Stainless steel scratch proof of approved shade.

-

-

-

... More
A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car.

-

-

-

... More
Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator.

-

-

-

... More
a) Combined luminous Hall Button and Digital Hall position indicator.

-

-

-

... More
b) Battery operated Alarm Bell and Emergency Light

-

-

-

... More
c) Firemen Switch

-

-

-

... More
d) Infra- red Door Curtain - Full screen.

-

-

-

... More
e) Integral full height car operating panel with luminous buttons with additional brail inscriptions, Digital car position indicator with Direction arrows, with overload warning indicator.

-

-

-

... More
Flooring: Decorative flooring as per manufacturer's standards.

-

-

-

... More
Ceiling: SS ceiling with LED lamp and fan.

-

-

-

... More
Dome camera for surveillance

-

-

-

... More
Passenger Lifts Describe as above

4

11636000

2909000

... More
SUB HEAD - II - AMC

-

-

-

... More
Providing comprehensive maintenance  of complete Lift Systems etc. Annual maintenance will start after One year extented warranty from commissioning of the equipment.

-

-

-

... More
1st year

1

698160

698160

... More
2nd year

1

740049

740049

... More
3rd year

1

784452

784452

... More
4th year

1

831519

831519

... More
5th year

1

881410

881410

... More
Carriage of Cement avg. 50kms

945.95

623031

658.63

... More
Carriage of Sand avg.25kms

3205.61

1491055

465.14

... More
carriage of Stone aggregate avg. 40 kms

661.84

453781

685.64

... More
Carriage of Bricks from Avg. 60 kms

190.7

432962

2270.35

... More
Carriage of AAC Blocks avg. 60 kms

92960

743680

8

... More
Carriage of Steel avg. 50 kms

64.28

42336

658.63

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :

-

-

-

... More
510x1040mm bowl depth 200mm

10

56718

5671.85

... More
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge

197

81183

412.1

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265mm sizes respectively

128

179206

1400.05

... More
Providing and fixing Flush pipe with union spreaders and clamps all in C.P. Brass for Single stall

128

57600

450

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete

-

-

-

... More
32 mm dia

197

27067

137.4

... More
40 mm dia

120

18096

150.8

... More
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour:

-

-

-

... More
Waste coupling 31mm of 79 mm length and 62 mm breadth weighing not less than 45gms

160

25624

160.15

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms.

12

2981

248.45

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour

-

-

-

... More
600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms

46

36961

803.5

... More
Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms

12

10027

835.65

... More
Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5mm flat of specified shape, projecting 75mm outside the wall surface and fixed on wall with 4 Nos, 6mm dia expansion hold fasteners including drilling necessary holes in brick wall/CC/RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30mm x 1.6mm galvanized M.S. flats of specified shape and of total length 420mm and shall be fixed with M.S. nuts, bolts and washers of size 25x6mm, one bolt on each side of the pipe.

-

-

-

... More
Total bracket length 580mm of approved shape and design (for single 100mm dia pipe)

240

70320

293

... More
Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge

197

4246236

21554.5

... More
Providing and Fixing raised toilet seat cover for handicap toilet.

10

25000

2500

... More
Providing and fixing in position 'U' shaped Grab Bar made up of Heavy Duty stainless steel (grade 304) of 750 mm in length & 40 mm dia (Outer dia with 3 mm thick sheet ) seamless pipe including Hinge,base plate and steel fastners, in the toilets as per manufacturers specification, as per drawings and "Harmonised Guidelines & Space Standard for Barrier Free Environment issued by MOUD, Govt Of India" to make them Accessible for Persons with Disabilities. Rate shall include all accessories, labour and material, complete as per direction of Engineer-in-charge.

10

131790

13179

... More
Providing and fixing 50 mm wide Yellow colour, self addhesive 'EDGE STRIPS' of approved make on risers of staircase to help persons with visual diabilities and elederly including cutting and pasting complete in all respect as per direction of Engineer-in-charge.

432

105869

245.07

... More
Providing and fixing Stainless Steel (Grade 304) Braille Labels of size 170mm x 35mm X 0.5 mm having Braille dots raised 0.5mm above base plate with one SS rivet of same grade and adhesive of approved make on handrails, complete as per the directions of the engineer in charge

55

29507

536.5

... More
Providing and fixing in position 'L' shaped Grab Bar made up of Heavy Duty stainless steel (grade 304) 40 mm (Outer dia with 3 mm thick sheet ) dia seamless pipe, & 750 mm in vertical length & 900 mm in horizontal length including base plate and steel fastners in the toilets as per manufacturers specification complete as per drawings and ''Harmonised Guidelines & Space Standard for Barrier Free Environment issued by MOUD, Govt Of India" to make them Accessible for Persons with Disabilities. Rate shall include all accessories, labour and material, complete as per direction of Engineer-in-charge

10

101330

10133

... More
Providing and fixing 150 mm long aluminium eye hook,polyester powder coated to required shade and colour, complete with necessary screws as per directions of Engineer- in - charge.

240

14448

60.2

... More
Providing and fixing under counter wash basin with , 15 mm dia CP Brass single hole basin mixer of quality and make as approved by the Engineer-in-Charge.

-

-

-

... More
White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer

147

758520

5160

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete

53

84540

1595.1

... More
Providing and fixing of 450mm long SS door handle in 12mm thick toughen glass door shutter

52

225940

4345

... More
Providing and fixing of door lock in 12mm thick toughen glass door shutter.

26

52000

2000

... More
Providing and fixing of retro reflective signage at different location of the building, made from aluminium 3mm thick sheet, as per approved by the engineer-in-charge.

100

1288700

12887

... More
Plumbing Works /Water Supplies

-

-

-

... More
Internal work- Exposed on wall

-

-

-

... More
Providing and fixing of Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pipes as per IAPMO IGC- INDIA 308, UMC-1TM certification marked on the pipe at the interval not greater than 1 meter with nominal pipe size with manufacturer’s name or trade mark including all relevant DZR brass fittings as Female Elbows/Tees, MTC /FTC and Engineering plastic fittings with internal sealing system like Eq. elbows, Eq. tees, reducers, Straight couplers, Clamps at one meter spacing, with PAP valves and brass tank Nipples etc. Including testing of lines and joints as per Engineer in charge. Make Kitec , Maithilee and Vista.

-

-

-

... More
2025 (25mm OD) pipe

300

127530

425.1

... More
2532 (32 MM OD) PIPE

838

434754

518.8

... More
3240 (40MM OD) PIPE

500

374975

749.95

... More
4050 (50mm OD) pipe

400

355640

889.1

... More
Internal work concealed with clamps at 1.00 meter spacing including cutting the chases and making good the wall etc

-

-

-

... More
1216 (16mm OD) pipe

100

49235

492.35

... More
1620 (20mm OD) pipe

500

257850

515.7

... More
Providing and fixing 15mm nominal bore C.P. brass bib cock of of approved quality conforming to IS:8931

200

116650

583.25

... More
Providing and fixing 15mm nominal bore C.P. brass LONG NOSE BIB COCK of approved quality conforming to IS standards and weighing not less than 810gms.

40

28504

712.6

... More
Providing and fixing 15mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS: 8931.

10

6903

690.3

... More
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931

541

315051

582.35

... More
Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms.

138

31740

230

... More
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.)

-

-

-

... More
For fixed portion

-

-

-

... More
Polyester powder coated aluminum (minimum thickness of polyester powder coated 50 microns)

25152

13146950

522.7

... More
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.)

-

-

-

... More
Polyester powder coated aluminum (minimum thickness of polyester powder coated 50 microns)

3583

2207128

616

... More
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.)

-

-

-

... More
With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)

533

640559

1201.8

... More
Providing and fixing Anodized aluminum grill (Anodized transparent or dyed to required shade according to IS: 1868 minimum anodic coating of Grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing windows frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved Anodized aluminum standard section around the opening, all complete as epr requirement and direction of Engineer-in-charge. (only weight of grill to be measured for payment)

1054

583705

553.8

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot &double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately)

135

603477

4470.2

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalization &drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanized / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineerin-charge. Theitem also includes the cost of all mock ups at site, cost of

-

-

-

... More
All samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note: - 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accredited by NABL (National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO /IEC 17011 and accredits labs as per ISO/ IEC 17025. 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml

2347

8375269

3568.5

... More
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube12mm wide, desiccants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-inCharge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.30.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement

2112

7512384

3557

... More
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer -in- Charge

422

1462989

3466.8

... More
Providing and fixing expansion hold fasteners on CC / R.C.C./brick masonry surface backing including drilling necessary holes and the cost of bolt etc. complete

-

-

-

... More
Fastener with threaded dia 12mm

1200

64620

53.85

... More
Providing and fixing at all floors Type-B SWR PVC pipe including all fittings such as plain and door bends,tees,elbows,equal and unequal junctions,heel rest sanitary bends,collars,etc,(except floor traps/p traps) conforming to IS 13592, IS 14735, including jointing with solvent and providing necessary supports,clamps/MS brackets at specific intervals,joints of pipe and fittings shall be of drip seal jointing in exposed areas like in shafts etc and pasted type(solvent) for all other locations all complete and as per direction of engineer-in-charge.MS brackets shall be paid seperately.

-

-

-

... More
110mm

875

393890

450.16

... More
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³. The frame will have a provision of G.I. Anchor fastners 14 nos (5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge. (Cost of SS ball bearing hinges is excluded)

320

583776

1824.3

... More
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes fire rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/sqm) duly filled mineral wool insulation having density minimum 96 kg/cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-Charge (panelling to be paid for seperately).

226

2213805

9795.6

... More
Providing and fixing tiled False Ceiling of specified materials of size 595x595mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms/sqm both side inclusive ) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200 x 600mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.30mm and laying false ceiling tiles of approved texture in the grid including, wherever, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along size 85x30x0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (The rate is excluding the cost of tiles which will be paid for separately).

-

-

-

... More
12.64.1 GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending .

1645

2896022

1760.5

... More
Providing and fixing P.V. CONNECTORS 18” of approved quality conforming to IS standards.

460

59800

130

... More
Providing and fixing C.P. NIPPLE 1” of approved quality conforming to IS standards.

320

22400

70

... More
Providing and fixing C.P JAALI (HOLE) of approved quality conforming to IS standards.

150

13500

90

... More
Providing and fixing C.P JAALI (PLAIN) of approved quality conforming to IS standards.

327

26160

80

... More
Providing and fixing HEALTH FAUCET WITH TUBE & HOOK of approved quality conforming to IS standards.

25

24950

998

... More
Providing and fixing GEYSER 25 LTR of approved quality conforming to IS standards.

15

88500

5900

... More
Providing and fixing GEYSER SINK MIXER WITH SWIVEL SPOUT of approved quality conforming to IS standards.

15

33570

2238

... More
CHAPTER-2 : INTERNAL DRAINAGE

-

-

-

... More
Supply, installation , testing & commissioning of UPVC SWR Pipe (ring type) Class B and fitting confirming to IS 14735 for soil, waste and vent pipe and Rain water downtake pipe conforming to IS:13592 cut to required lengths including door piece, bends, tee, y-tee, plain tee, door tee and all necessary fittings and specials. Cost shall be inclusive of providing and Fixing of pipes and fittings at wall/ceiling level with all type of supported by MS hot dipped galvanised angle support for vertical and horizontal pipe fixing with GI u clamp & hangers etc. Making proper connection with cement solvent joint as per BIS / manufacturer. Cutting chases/holes in floors/walls/slab etc. The vertical downtake shall be supported with thrust block. Contractor shall submit support details for approval prior to execution of works at site.

-

-

-

... More
(a) 40 mm dia (6 bar pressure rated)

600

210000

350

... More
(b) 50 mm dia (6 bar pressure rated)

125

65625

525

... More
(C) 110 mm dia (6 bar pressure rated)

2125

2071875

975

... More
(D) 160 mm dia (6 bar pressure rated)

1050

1312500

1250

... More
Supply, installation , testing & commissioning in position SWR PVC P trap of self cleaning design of following sizes for the embedded areas with minimum water seal of 70 mm. Making proper connection with. Cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required. a) 110mm inlet and 110mm outlet

222

144300

650

... More
Supply, installation , testing & commissioning PVC saddle for connecting two or three inlet waste connection of 32/40 and 63mm nominal dia , including cutting and chasing as required to complete the job.

222

77700

350

... More
Supply, installation , testing & commissioning 100mm x 63mm PVC waste reducing elbow including cutting chases, making holes in the floor / slab, repairs complete as required and connection to pvc pipes

85

29750

350

... More
Supply, installation , testing & commissioning upvc floor/ceiling clean out plug with suitable inlet key for opening male threaded joint with UPVC pipe & socket. Including socketed joint complete as per approved specifications. For 110 mm dia pipe

208

260000

1250

... More
Supply, installation , testing & commissioning upvc floor/ceiling clean out plug with suitable inlet key for opening male threaded joint with UPVC pipe & socket. Including socketed joint complete as per approved specifications. For 160 mm dia pipe

2

3100

1550

... More
Supply, installation , testing & commissioning of 150 mm diameter SS -304 grating for rain water verticals including cement mortar for fixing at roof level complete as required.

40

26000

650

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)

-

-

-

... More
25 mm nominal bore

30

20751

691.7

... More
20 mm nominal bore

80

41072

513.4

... More
32 mm nominal bore

32

24000

750

... More
40 mm nominal bore

30

25038

834.6

... More
50 mm nominal bore

10

9861

986.15

... More
65 mm nominal bore

10

16460

1646.05

... More
80 mm nominal bore

5

13025

2605.15

... More
EXTERNAL SEWER AND STORM

-

-

-

... More
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: 2.9.1 All kinds of soil :

1050

269692

256.85

... More
Supply, installation , testing & commissioning of UPVC SWR Pipe (ring type) Class B and fitting confirming to IS 14735 for soil, waste and vent pipe and Rain water downtake pipe conforming to IS:13592 cut to required lengths including door piece, bends, tee, y-tee, plain tee, door tee and all necessary fittings and specials. Cost shall be inclusive of providing and Fixing of pipes and fittings at wall/ceiling level with all type of supported by MS hot dipped galvanised angle support for vertical and horizontal pipe fixing with GI u clamp & hangers etc. Making proper connection with cement solvent joint as per BIS / manufacturer. Cutting chases/holes in floors/walls/slab etc. The vertical downtake shall be supported with thrust block. Contractor shall submit support details for approval prior to execution of works at site.

-

-

-

... More
(a) 160 mm diameter

300

375000

1250

... More
(b) 250 mm diameter

800

1953600

2442

... More
Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches for pipes including bed concrete as per standard design.

-

-

-

... More
(a) 150 mm dia.

300

165060

550.2

... More
(b) 250 mm dia.

800

602360

752.95

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P type With sewer bricks conforming to IS : 4885

25

56911

2276.45

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

36

415206

11533.5

... More
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

22

547562

24889.2

... More
(b) Extra for depth for manholes : Size 90x80 cm With Sewer bricks conforming to IS : 4885

0.5

4529

9059.2

... More
(c)Size 120x90 cm With Sewer bricks conforming to IS : 4885

2

21705

10852.5

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar Conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

100

48360

483.6

... More
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 5.0

30

170388

5679.6

... More
Cleaning theouter surface of ACC block by way of removing dirt dust,bird dropping,grease oil algae, fungue,monkey beads, vegetable grouts etc by using scrubbers,pressure jet machine and finally washing the surface with clean wateras per the direction of the Engineer incharge.(rate is inclusive of Scafolding complete job.)

7350

396900

54

... More
Providing and fixing of pvc vent cowl ( 100mm )

35

6300

180

... More
CHAPTER 1: HT CABLE & TERMINATION

-

-

-

... More
Supplying, testing and commissioning of following size 3 core , 11KV (E) (unearthed) grade, heavy duty XLPE insulated, FRLS type, aluminium armoured cables suitable for 11kV, 50Hz, AC system with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel flat armouring and with all components as mentioned in BOQ, specifications and schedule, complete as required. 300 sq. mm

200

644600

3223

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 300 sq. mm

5

81245

16249

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 300 sq. mm

3

68385

22795

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm

170

98090

577

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm

30

3450

115

... More
CHAPTER 2: HT PANEL

-

-

-

... More
Notes : - Cubicle shall be type tested for internal arc for all compartment for 25KA for 1sec as per IEC 62271-200. - Cubicle manufacturer should also be the manufacturer of Vacuum Interrupters used. 01 NO. INCOMING/OUTGOING (INSIDE METER ROOM) Supplying, installation , testing and commissioning of totally enclosed, fully extendable from both sides,roll on floor type, metal clad, indoor type, horizontal drawout horizontal isolation type, dust/ corrosion/vermin proof , HT panel suitable for 12kV, 630A. 25kA for 3 sec, internal arc tested ( from all sides viz. front, lateral and rear) for rated fault current rating for 1s, fabricated out of CRCA / Aluzinc sheet steel throughout (thickness as per type test design), mounted upon suitable size ISMC-100 channel, properly grouted, with all necessary internal power and control wiring complete with terminal blocks marking and ferruling including dc circuit wiring from power pack to respective panel (power pack shall be a part of HT panel and shall be included in cost), interpanel and intrapanel ac/dc circuit wiring ,copper busbars of suitable ratings for phase as well as earth, metallic seperations of CRCA / Aluzinc sheet (thickness as per type test design) between each switchgear and control gear compartment, approved danger and arc flash signages and with all components as mentioned in BOQ, specifications and schedule, complete with following as required. Surge arrester (1 Nos.) 9kV,10kA, metal oxide varistor type surge arrestor suitable fo both lightning and switching surges,complete with its bushings and earthing terminations etc. as required. Line PT (1 Nos.) 2 core line mounted, fixed type,3 phase (3 x 1 phase), cast resin, potential transformer with rated turn/voltage ratio of 11000/(1.732):110/(1.732) ,rated burden of 50 VA, 11kV rated inbuilt primary side fuse,110V rated secondary and tertiary side fuses complete with isolating plugs as required. Core 1 : CL 0.5, star connected with neutral grounded for metering and indications. Core 2 : CL 3P, star connected with neutral grounded for protections. VCB (1 Nos.) 11kV, 50Hz, 630A, 350 MVA, 3P, 25kA for 3 sec rated, drawout type, VCB breaker panel with 110 volts DC closing and tripping coils, with a provision of secondary trip coil and 230 Volts AC spring charging motor, locking magnet, inbuilt antipumping relay, potential free NO & NC contacts required in addition to 4 spare NO and 4 spare NC contacts, door interlocking, racking interlocking and any other controls or interlocks as described in specifications or schedules, solenoids, TNC switch and inbuilt earth switch, connected on the line side of VCB and mechanically interlocked with VCB, complete as required. Indication lamps (12 Nos.) LED type phase indication lamps suitable for 110V,50Hz AC (red, yellow, blue) LED type Indication lamps for breaker, suitable for 110V DC supply (on, off, trip, test, service, spring charge,TCH,earth switch on) LED type Indication lamps for DC healthy, suitable for 110V DC supply. Micro Processor based non directional IDMT instantaneous relay module having following inbuilt functions: 3 nos. Overcurrent protection with settings from 50% to 200% and earth fault protection with settings from (10 - 40%), under voltage ( with dead band bypass feature), over load protection, frequency based protection , phase sequence protections, the relay module shall be suitable to record and store at least 100 events with date and time with last five fault records stored in nonvolatile memory and with self supervision function, 4 spare digital binary inputs and 4 spare digital output contacts in addition to those required as per the scheme, modbus communication protocol, breaker control (on/off) complete as required. - 1Set. CT chamber with, single phase, Single ratio cast resin CT, 15VA burden with core for protection (CL-5P10) and of 80/5+5+5 A ratio. - 3 Nos. Electro-mechanical relay: Hinged armature type electromechanical master trip (lockout) relay complete with assembly- 1 Nos. Hinged armature type trip circuit supervision relay complete with assembly- 1 Nos. Hinged armature type dc fail relay complete with assembly- 1 Nos. PT fuse failure relay - 1 Nos. Metering (1 Nos.) Multifunction meter with inbuilt selector switch for measurement of current, voltage, power factor, KVA, kVAh, KVArh, KVAR, frequency, %THD (upto 15th order), THDi,THDv,KWHr (both line and phase) and maximum demand recording and indicating etc. complete as per specifications, RS-485 port along with 3No. 11kV ,100/1A, 2.5VA, CL-1 current transformer as required - 1 No. 0-11000 volts analog type voltmeter with selector switch for Vr, Vy, Vb - 1 No. Emergency trip button on front door at an accessible height -1 Nos. Selector type auto / manual switch -1 Nos. 230 volt, 50Hz,AC operated Hooter with noise level of 80db at every 3 metres with acknowledge and reset push button-1 Nos. 16-window microprocessor based annunciation panel with visual LED indicator complete as per specifications and schedule as required. - 1 Nos. All control wiring with protection & test terminal block as required - 1 Set. Strip heater with thermostat for moisture absorption. - 1 Set Suitable for connection to 3 core x 300 sq.mm. Cross linked polyethylene (XLPE) 11KV cables or as called for

1

505219

505219

... More
01 NO. INCOMING AND 02 NOS. OUTGOING (INSIDE SUBSTATION) Supplying, installation , testing and commissioning of totally enclosed, fully extendable from both sides,roll on floor type, metal clad, indoor type, horizontal drawout horizontal isolation type, dust/ corrosion/vermin proof , HT panel suitable for 12kV, 630A. 25kA for 3 sec, internal arc tested ( from all sides viz. front, lateral and rear ) for rated fault current rating for 1s, fabricated out of CRCA / Aluzinc sheet steel throughout (thickness as per type test design), mounted upon suitable size ISMC-100 channel, properly grouted, with all necessary internal power and control wiring complete with terminal blocks marking and ferruling including dc circuit wiring from power pack to respective panel (power pack shall be a part of HT panel and shall be included in cost), interpanel and intrapanel ac/dc circuit wiring ,copper busbars of suitable ratings for phase as well as earth, metallic seperations of CRCA / Aluzinc sheet (thickness as per type test design) between each switchgear and control gear compartment, approved danger and arc flash signages and with all components as mentioned in BOQ, specifications and schedule, complete as required. Incomer Surge arrester (1 Nos.) 9kV,10kA, metal oxide varistor type surge arrestor suitable fo both lightning and switching surges,complete with its bushings and earthing terminations etc. as required. Line PT (1 Nos.) 2 core line mounted, fixed type,3 phase (3 x 1 phase), cast resin, potential transformer with rated turn/voltage ratio of 11000/(1.732):110/(1.732) ,rated burden of 50 VA, 11kV rated inbuilt primary side fuse,110V rated secondary and tertiary side fuses complete with isolating plugs as required. Core 1 : CL 0.5, star connected with neutral grounded for metering and indications. Core 2 : CL 3P, star connected with neutral grounded for protections. VCB (1 Nos.) 11kV, 50Hz, 630A, 350 MVA, 3P, 25kA for 3 sec rated, drawout type, VCB breaker panel with 110 volts DC closing and tripping coils, with a provision of secondary trip coil and 230 Volts AC spring charging motor, locking magnet, inbuilt antipumping relay, potential free NO & NC contacts required in addition to 4 spare NO and 4 spare NC contacts, door interlocking, racking interlocking and any other controls or interlocks as described in specifications or schedules, solenoids, TNC switch and inbuilt earth switch, connected on the line side of VCB and mechanically interlocked with VCB, complete as required. Indication lamps (12 Nos.) LED type phase indication lamps suitable for 110V,50Hz AC (red, yellow, blue) LED type Indication lamps for breaker, suitable for 110V DC supply (on, off, trip, test, service, spring charge,TCH,earth switch on) LED type Indication lamps for DC healthy, suitable for 110V DC supply Micro Processor based non directional IDMT instantaneous relay module having following inbuilt functions: 3 nos. Overcurrent protection with settings from 50% to 200% and earth fault protection with settings from (10 - 40%), under voltage ( with dead band bypass feature), over load protection, frequency based protection , phase sequence protections, the relay module shall be suitable to record and store at least 100 events with date and time with last five fault records stored in nonvolatile memory and with self supervision function, 4 spare digital binary inputs and 4 spare digital output contacts in addition to those required as per the scheme, modbus communication protocol, breaker control (on/off) complete as required. - 1Set. CT chamber with, single phase, Single ratio cast resin CT, 15VA burden with core for protection (CL-5P10) and of 150/5+5+5 A ratio. - 3 Nos.

1

1474116

1474116

... More
Electro-mechanical relay (3 Nos.) Hinged armature type electromechanical master trip (lockout) relay complete with assembly- 1 Nos. Hinged armature type trip circuit supervision relay complete with assembly- 1 Nos. Hinged armature type dc fail relay complete with assembly- 1 Nos. PT fuse failure relay - 1 Nos. Metering (1 Nos.) Multifunction meter with inbuilt selector switch for measurement of current, voltage, power factor, KVA, kVAh, KVArh, KVAR, frequency, %THD (upto 15th order), THDi,THDv,KWHr (both line and phase) and maximum demand recording and indicating etc. complete as per specifications, RS-485 port along with 3No. 11kV ,150/1A, 2.5VA, CL-1 current transformer as required - 1 No. 0-11000 volts analog type voltmeter with selector switch for Vr, Vy, Vb - 1 No. Emergency trip button on front door at an accessible height -1 Nos. Selector type auto / manual switch -1 Nos. 230 volt, 50Hz,AC operated Hooter with noise level of 80db at every 3 metres with acknowledge and reset push button-1 Nos. 16-window microprocessor based annunciation panel with visual LED indicator complete as per specifications and schedule as required. - 1 Nos. All control wiring with protection & test terminal block as required - 1 Set Strip heater with thermostat for moisture absorption. - 1 Set Suitable for connection to 3 core x 300 sq.mm. Cross linked polyethylene (XLPE) 11KV cables or as called for. Busbar : Busbar (1 Set - 3P + E) Busbar made up of electrolytic grade high conductivity copper in tubular / ractangular cross section and suitable for 11 KV, TP 50 Hz, 630 A, 25 kA for 3 sec of required length and cross sectional area. Note : Concerning vendor needs to furnish the busbar calculations (for both phase and earth bus) at the time of GA approval and busbar size has to be as per the approved GA drawing. Bus PT (1 No.) - 2 core bus mounted, drawout type,3 phase, cast resin, potential transformer in a seperate compartment, with rated turn/voltage ratio of 11000/(1.732):110/(1.732) ,rated burden of 50 VA, 11kV rated inbuilt primary side fuse,110V rated secondary and tertiary side fuses complete with isolating plugs as required. Core 1 : CL 0.5, star connected with neutral grounded for metering and indications. Core 2 : CL 3P, star connected with neutral grounded for protections. PT Rackout trolley. - 1 No. PT fuse relay. 1 No. Interlocking and control functions as per specifications & schedule. 0-11000 Volts analog type voltmeter with selector switch for Vr, Vy, Vb - 2 No. LED type phase indication lamps suitable for 110V,50Hz AC (red, yellow, blue,earth truck on) - 1 No. 110V DC operated earth truck suitable for 11kV bus - 1 No.

-

-

-

... More
Outgoing : Indication lamps (24 Nos.) LED type phase indication lamps suitable for 110V,50Hz AC (red, yellow, blue) LED type Indication lamps for breaker, suitable for 110V DC supply (on, off, trip, test, service, spring charge,TCH,earth switch on) LED type Indication lamps for DC healthy, suitable for 110V DC supply. Micro Processor based non directional IDMT instantaneous relay module having following inbuilt functions: 3 nos. Overcurrent protection with settings from 50% to 200% and earth fault protection with settings from (10 - 40%), under voltage ( with dead band bypass feature), over load protection, frequency based protection , phase sequence protections, the relay module shall be suitable to record and store at least 100 events with date and time with last five fault records stored in nonvolatile memory and with self supervision function, 4 spare digital binary inputs and 4 spare digital output contacts in addition to those required as per the scheme, modbus communication protocol, breaker control (on/off) complete as required. - 1Set. CT chamber with, single phase, Single ratio cast resin CT, 15VA burden with core for protection (CL-5P10) and of 75/5+5+5 A ratio. - 3 Nos. Numeric relay module (for safe tripping of transformer's 11kV feed breaker) with LCD dislpay having following inbuilt protection functions : Restricted earth fault protection of transformer, high winding temperature, suitable to record and store at least 100 events with date and time with last five fault records stored in nonvolatile memory and with self supervision function, 4 spare digital binary inputs and 4 spare digital output contacts in addition to those required as per the scheme, modbus communication protocol with RS-485 Port, breaker control (on/off) along with 3No. 11kV ,75/1A, 2.5VA, CL-5P10 current transformers, complete as required. - 2 Nos. Electro-mechanical relay (2 Nos.) Hinged armature type electromechanical master trip (lockout) relay complete with assembly- 1 Nos. Hinged armature type trip circuit supervision relay complete with assembly- 1 Nos. Hinged armature type dc fail relay complete with assembly- 1 Nos. PT fuse failure relay - 1 Nos. Metering (2 Nos.) Multifunction meter with inbuilt selector switch for measurement of current, voltage, power factor, KVA, kVAh, KVArh, KVAR, frequency, %THD (upto 15th order), THDi,THDv,KWHr (both line and phase) and maximum demand recording and indicating etc. complete as per specifications, RS-485 port along with 3No. 11kV ,75/1A, 2.5VA, CL-0.5 current transformer as required - 2 No. 0-11000 volts analog type voltmeter with selector switch for Vr, Vy, Vb - 2 No. Required Auxiliary relays for Bucholtz, Oil ,WTI (Winding temperature indication with alarm & trip) - 1 Set for each transformer Emergency trip button on front door at an accessible height-2 Nos. Selector type auto / manual switch -2 Nos. 230 volt, 50Hz,AC operated Hooter with noise level of 80db at every 3 metres with acknowledge and reset push button-2 Nos. 16-window microprocessor based annunciation panel with visual LED indicator complete as per specifications and schedule as required. - 2 Nos. VCB (2 Nos.) 11kV, 50Hz, 630A, 350 MVA, 3P, 25kA for 3 sec rated, drawout type, VCB breaker panel with 110 volts DC closing and tripping coils, with a provision of secondary trip coil and 230 Volts AC spring charging motor, locking magnet, inbuilt antipumping relay, potential free NO & NC contacts required in addition to 4 spare NO and 4 spare NC contacts, door interlocking, racking interlocking and any other controls or interlocks as described in specifications or schedules, solenoids, TNC switch and inbuilt earth switch, connected on the line side of VCB and mechanically interlocked with VCB, complete as required.

-

-

-

... More
CHAPTER 3: TRANSFORMER Supplying, installation testing and commissioning of, outdoor type, oil cooled distribution transformer, suitable for 3 phase, 50HZ, AC supply with rated power of 1250kVA complete with the following standard, mountings, fittings, approved danger and arc flash signages and with all components & accessories as mentioned in BOQ, specifications and schedule, complete as required. The Transformer must confirm to the IS standards specified in the technical specifications. Rated Turn / Voltage ratio - 11kV/433V Vector Group - Dyn11 Cooling - Oil Natural Air Natural (ONAN) mechanism Core - Core made of good quality CRGO, double wound copper Insulation Class - 'A' Temperature rise : 50/55 Deg. (oil / winding) Impedance - 5.00% Automatic on load tap changer with RTCC. Remote tap changer circuit (RTCC) panel with all associated accessories as per schedules and specifications. Taps on HV for HV variation : +5% to - 15 % in the steps of 2.5% with AVR Cable termination box with disconnecting facility for 11 KV XLPE cable at 11 KV side. Cable termination box with disconnecting facility for 1.1 KV XLPE cable at 0.433 KV side. Provision for CTs for REF protection shall be provided (CTs shall be provided loose as free issue item by the LT Panel Manufactrure to be fixed by Transformer Manufacturer either at site or works as the case may be) The transformer shall be supplied with Standard fittings as per specifications including the following : a. Conservator with drain valve. b. Silicagel breather with oil seal. c. First filling of oil as per IS 335 including make up during installation of transformer plus 10% extra oil. To be supplied - in a container. d. Thermometer pocket with plug e. Air release plug f. Inspection cover g. Top filter brass gate valve - 1 no. h. Removable Lifting lugs and Jack lifting pad support i. Earthing terminals - 2 nos.for body earth and neutral earthing bushing terminal on transformer top cover. j. Radiator with top and bottom shut off brass gate valves k. Rating and Diagram plate. l. Bi-directional Plain/Flanged Rollers. m. Drain cum bottom filter valve - 1 no. n. Explosion vent with double diaphragm and sight glass. o. Buchholtz relay with shut off valve. p. 100 mm dial magnetic oil level gauge with max pointer and low level alarm contacts. q. 150 mm dial oil temperature indicator (OTI) with max pointer and 2 sets of Contact for Alarm & trip. r. 150 mm dial winding temperature indicator (WTI) with max pointer & 2 sets of contacts for alarm & trip. s. Magnetic oil level indicator with annunciation. t. Marshalling box with watertight lockable cover lid, lamp point, 15A switchsocket oulet point and all associated accessories as per schedules and specifications. NOTE :- Item nos. o, p, q, r, s, t shall be suitable for termination of multicore (minimum 6 core 2.5 sq.mm. Copper ) conductor armoured cable connecting between respective equipment to terminal block in marshalling box to annunciation window panel and to main breaker as required.( The Transformer losses shall be as per ECBC guideline). The total Transformer losses at Rated load, Voltage & frequency to be as per IS 1180 (Energy Efficiency Level 2 or better) Supply, installation, testing & commissioning of RTCC panel suitable for Remote Operation of 2000 KVA 11 KV/433 Volts Transformer , made of sheet steel cabinet for indoor installation, floor mounting type. The RTCC panel shall be fabricated out of 14 SWG CRCA sheet, totally enclosed, completely dust and vermin proof and shall be with hinged doors, Neoprene gasket and padlocking arrangement. Self threading screws shall not be used in the construction of RTCC panel. A base channel of 75 mm x 40 mm x 5 mm thick shall be provided at the bottom for floor mounted panel. Panels and covers shall be properly fitted and square with the frame, and holes in the panel correctly positioned. Fixing screws shall enter into holes tapped into an adequate thickness of metal or provided with wing nuts. (rate included 02 each) RTCC Panel shall be complete with following accessories complete as required. a. The following components shall be provided in the RTCC panel : b. Digital Tap Position Indicating Meter c. Raise/Lower Push Buttons for Remote Control of OLTC d. Tap Change in Progress Signal Lamp. E. Supply on Signal Lamp f. Local / Remote Control Indicating Lamps g. Panel illuminating lamp with door switch. h. Space Heater with Switch and Thermostat. i. Automatic Voltage Relay with Time Delay Element. j. Selectors switch for Auto/Manual Operation. k Undrilled Gland Plate for Cable entry. l. Earthing Terminal m. Lifting Eyes Bolts. n. Suitable potential free contacts shall be provided. o. Control Cabling form RTCC Panel to Transformer.

2

9065870

4532935

... More
Creation of 11KV Tapping point on two pole struture with GOAB 9 Insulator 3 Pole 400 AMP Note- Above said item will oiperate as per the cost data 2022-23 and item mentioned and any missing shall operate shall precribed by JPDCL

1

90611

90611

... More
Erection of ACSR conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc as required

600

160800

268

... More
CHAPTER 4: DG SET

-

-

-

... More
Supplying, installation, testing and commissioning of 160 kVA silent type DG set (with acoustic canopy) complete with following accessories

1

1466538

1466538

... More
Supplying, installation, testing and commissioning of 4 stroke Diesel engine of suitable BHP at 1500 rpm suitable for 160 kVA output of the alternator at site condition, capable of taking 10% overloading for one hour in any 12 hrs of running without loosing its rpm complete with Dynamically balanced flywheel,preferably flexible coupling,Exhaust gas turbo charged with Cooling System , Automatic safety control in case of low lubrication oil pressure, Automatic safety control in case of high water temperature. Automatic overspeed trip protection. The engine shall have Lubrication oil pump.Lubrication oil filter.Lubrication oil cooler.Bye-pass filter,Fuel pump,Fuel Filter,Hoses for fuel tank.Air intake manifold.Air cleaner dry type. Governor EFC Type .Selfstarter.Alternator for battery charging.Residential silencer. Flexible pipe for silencer. Batteries for excitation with Battery charger.Techometer with hour meter,Auto mains failure controller, Engine control panel as applicable & as per manufacturers standard .

-

-

-

... More
Supplying, installation, testing and commissioning of synchronous alternator rated 160 KVA at 1500 rpm, 3 phase ,50Hz AC supply with 0.8 pf (lagging) at site condition.The alternator shall have SPDP enclosure (IP-23), brushless contineous duty, self excited and self regulated suitable for the environmental conditions and with H class of insulation.The alternator shall be fitted with thermistors (controlled by AMC controller) for winding and bearing temperature and space heaters, AVR , battery charger for self excitation etc. complete in all respects.The alternator shall be fitted with suitable arrangement to bring out bus duct/cables of required sizes as mentioned in the SLD, along with CT for restricted earth fault protection and droop compensation .The rate shall include complete supplying, installation, testing and commissioning rates including cost of all tools and accessories (as mentioned below and any other required) required to Complete the job in full respect.

-

-

-

... More
Supplying, installation, testing and commissioning of 380 kVA silent type DG set (with acoustic canopy) complete with following accessories

1

2533111

2533111

... More
Supplying, installation, testing and commissioning of 4 stroke Diesel engine of suitable BHP at 1500 rpm suitable for 380 kVA output of the alternator at site condition, capable of taking 10% overloading for one hour in any 12 hrs of running without loosing its rpm complete with Dynamically balanced flywheel,preferably flexible coupling,Exhaust gas turbo charged with Cooling System , Automatic safety control in case of low lubrication oil pressure, Automatic safety control in case of high water temperature. Automatic overspeed trip protection. The engine shall have Lubrication oil pump.Lubrication oil filter.Lubrication oil cooler.Bye-pass filter,Fuel pump,Fuel Filter,Hoses for fuel tank.Air intake manifold.Air cleaner dry type. Governor EFC type .Selfstarter.Alternator for battery charging.Residential silencer. Flexible pipe for silencer. Batteries for excitation with Battery charger.Techometer with hour meter,Auto mains failure controller, Engine control panel as applicable & as per manufacturers standard .

-

-

-

... More
Supplying, installation, testing and commissioning of synchronous alternator rated 380 KVA at 1500 rpm, 3 phase ,50Hz AC supply with 0.8 pf (lagging) at site condition.The alternator shall have SPDP enclosure (IP-23), brushless contineous duty, self excited and self regulated suitable for the environmental conditions and with H class of insulation.The alternator shall be fitted with thermistors (controlled by AMC controller) for winding and bearing temperature and space heaters, AVR , battery charger for self excitation etc. complete in all respects.The alternator shall be fitted with suitable arrangement to bring out bus duct/cables of required sizes as mentioned in the SLD, along with CT for restricted earth fault protection and droop compensation .The rate shall include complete supplying, installation, testing and commissioning rates including cost of all tools and accessories (as mentioned below and any other required) required to Complete the job in full respect.

-

-

-

... More
EXHAUST PIPING: Providing, laying, testing & commissioning of 'C' Class heavy duty ERW MS pipe conforming to IS 3589/IS 1239 including welding, fitting like elbows, tees, flanges, tappers, nuts, bolts, gaskets etc. and fixing pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:

-

-

-

... More
200mm (NB) MS ERW pipe 4.85mm thick (vertical).

15

202965

13531

... More
200mm (NB) MS ERW pipe 4.85mm thick (Horizontal).

30

405930

13531

... More
125mm (NB) MS ERW pipe 4.85mm thick (vertical).

15

179010

11934

... More
125mm (NB) MS ERW pipe 4.85mm thick (Horizontal).

30

358020

11934

... More
Supply, installation, testing and commissioning of 75mm thick Rockwool LRB mattress insulation (of 150 Kgs. Per cubic meter density) over the exhaust pipes of following diameter including cladding with aluminum sheet of 26 SWG and covering from outside complete as required suitable for DG exhaust pipe temp. upto 450OC etc. as per specifications (for horizontal pipes).

-

-

-

... More
200mm (NB)

40

119400

2985

... More
125mm (NB)

40

85320

2133

... More
Insulation of silencers for DG Set

2

47744

23872

... More
Supply, installation, testing and commissioning of DG Exhaust pipe insulation with first layer of 25mm thick Ceramic Fibre wool insulation (of 96 Kgs. Per cubic meter density) and 2nd layer of 100mm thick Rockwool (of 150 kgs. Per cubic meter density) over the exhaust pipes of following diameter including cladding with aluminum sheet of 26 SWG and covering from outside complete as required suitable for DG exhaust pipe temp. upto 450OC. (Surface temperature of exhaust pipe shall be maximum ambient + 15OC but not exceeding more than 60OC) as per specifications (for vertical pipes).

-

-

-

... More
200mm (NB)

5

19105

3821

... More
125mm (NB)

5

12950

2590

... More
Supply & Fixing of miscellaneous structural support for horizontal/ vertical exhaust & raw water piping including fabrication, hardwares and painting as per specifications.

2500

345000

138

... More
Supply & Fixing of SS expansion joints for horizontal/ vertical exhaust pipes as required at site:

-

-

-

... More
200mm exhaust SS Bellows for 380 KVA (400mm long)

2

85888

42944

... More
125mm exhaust SS Bellows for 160 KVA (400mm long)

2

44630

22315

... More
Supplying, fixing , wiring, testing and commissioning of aviation lighting fixtures, made of cast aluminium fitted with polycarbonate cover with LED or approved equivalent.

1

50873

50873

... More
Supply, fabrication, installation, testing & commissioning of M.S. day oil tank of 990 litres capacity fabricated out of min. 2mm thick M.S. sheet installed on steel frame or masonry pedestal, suitably treated with anticorrosive treatment on inside & outside surface with all associated accessories, filters, valves & fittings including level indicator and float switch complete as required.

2

88414

44207

... More
Providing, fixing, testing & commissioning of M.S. class `C' (heavy duty) pipes conforming to IS:1239 and fittings like tees, elbows, junctions, unions, bends, plugs, flanges and valves as per P.I.D etc. clamps, structural supports as required/ directed at site including jointing of pipes, cutting & making good the walls, floors, RCC work etc. cutting chases & filling the same with cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size) or cement mortar 1:4 (1 cement :4 coarse sand) as required including painting the pipes with desired shade of enamel paint over a coat of primer along with pyp coating over the pipes in roadcrossing area.

-

-

-

... More
25 mm dia

30

13290

443

... More
32 mm dia

10

6830

683

... More
Providing, fixing, testing & commissioning of Cast Steel ball/Plugh valves of the following sizes tested to 15 kg/sqcm pressure. Flanged to class ASA 150 on screwed ends/flanges ends.

-

-

-

... More
25 mm dia

7

8666

1238

... More
32 mm dia

3

6897

2299

... More
CHAPTER 5: LT PANELS

-

-

-

... More
Supply, installation, testing and commissioning of indoor/outdoor floor mounted/ wall mounted, IP43/IP65, factory built, modular, sectionalised, compartmentalized, extendable type LT cubicle panel of suitable size suitable for operation on 433/415 volts, 50 Hz AC 3 phase 4 wire supply system fabricated from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process or better before painting for surface treatment and powder coated in approved shade, with suitable electrolytic grade high conductivity bus bars extensible, DMC/ SMC (whichever is superior) bus bar supports, with short circuit withstand capacity as mentioned ,bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor S/C cable for voltage & current respectively, including providing and fixing following switch gears and as per schedules ,technical specifications etc.complete as required.

-

-

-

... More
The Switchboards shall have provision to accommodate all cables from the bottom /top as required. All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves according to the colour code. SMC shrouds and busbar supports shall be used. All MCCB door handle shall be interlocked and lockable in OFF position. Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards. Suitable Aluminium earth bus to be provided throughout the length of Switchboards. All indication lamps / illuminated push buttons shall be LED type. 2A SP MCBs shall be used as backup protections. All MCCBs shall be provided at least with ON, OFF & Trip indication lamps. All MCCBs shall be with thermal magnetic releases up to 250 A rating and with microprocessor based releases above 250 A rating, line load reversibility, Ics = 100% Icu,& extended rotary handle unless otherwise specified

-

-

-

... More
All MCCB shall have rotary handle with pad locking arrangement. All micrprocessor based MCCBs shall have inbuilt earth fault protection with variable earth fault settings & last fault trip history and all thermal magnetic based MCCBs shall be provided earth fault protection through E/F module with fault differentiation. Door interlocking for all outgoing feeders shall be provided. All TP MCCB'S shall have solid neutral link,disconnect type. All control & power wiring shall be broughtout upto the cable alley in the terminal blocks. All ACBs shall be with micropocessor based releases (O/C, S/C, E/F & Instantaneous). All ACBs shall have ZSI protection & trip history. All outgoing terminals shall be provided in cable alley on proper insulated supports (SMC/DMC). All rear door of Main Isolation Panel shall be almirah type with lockable arrangement. Space heater shall be provided with thermostat with 6A MCB as backup protection inside all cable alleys controlled with feeder 20 A DP MCB 10 KA. An approval shall be taken for each panel before manufacturing. Provision of one 6/16 amp socket & compartment lighting for each vertical section of panel. 5 nos extra of each R,Y,B,G,A colour indicating lamp and illuminated push buttons and normal push button shall be provided with all panels. MIMIC diagram shall be provided for Main Isolation panel MIMIC shall be made of polycarbonate sheet of 5 mm thickness fixed on acylic sheet of 2mm thick.the size of panel shall be such that the diagram can be visualized from 5 to 6 meter distance. The panel shall display complete single line diagram of Main LT Panel. this line diagram shall be made from luminous non fading materials to glow in dark and each breaker legend shall be provided with bi-colour LED lights to show the ON/OFF status of the respective feeder (Incomers / Bus couplers) Illuminated push button on Starter Panels of Pumps. Interlocking / Auto start command terminals for starter Panels. All breaking Capacity for ACB to be Ics=100%Icu and Icw for 1 sec.. All breaking Capacity for MCCB to be Ics=100%Icu and Uimp of 8KV & shall be single frame till 250A to save the inventory All ACB's shall have all standard accessories such as CT's Arc chute,safety shutter,etc. Links and drops from ACB/MCCB shall be designed for full rated current of ACB/MCCB rating at same amount of current density as of main busbar. All MCB to be C Curve for raw power and D curve for UPS power. Removable lifting hook shall be provided in all transportation section. Each Section of the Main isolation to be provided with Ventilation Fans. Multifunction meters installed shall be BMS Compatible, capable of delivering Bacnet, Modbus or Lonworks protocol etc. Bus bar shall be high conductivity (99%), ETP - Electrical grade copper or 50-55% Aluminium as specified in BOQ. Bus bar shall be designed on 45 deg. Ambient temperature and limit of temperature rise shall be 35 deg. Over and above Ambient temperature. Bus bars shall be with heat shrinkable PVC sleeves. MCB's shall be of minimum 10kA fault with stand capacity. Concerning vendor needs to furnish the busbar calculations (for both phase and earth bus) at the time of GA approval and busbar size has to be as per the approved GA drawing. ACBs upto highest rating in Main isolation Panel shall be provided with top horizontal and bottom vertical terminal adapters on both sides for proper cable connections/bus duct connections. No Deration in ACBs till 50deg.C and as per deration higher rating to be selected. All ACBs shall communicate on/off, trip and Ready to Close status with remote on/off control on Modbus RS485

-

-

-

... More
Main Panel (Loc.-Basement)

-

-

-

... More
Incomers from Transformers : 2 x 2000 A, FP, 50 kA, Electrically draw out type ACB with inbuilt LSIG protection with microprocessor based release, shunt release (24V DC), inbuilt O/C & SC releases (Microprocessor based) having variable range with time lag facility to acheive discrimination. And required Interlocking between other incomer & Bus Coupler to be provided as per Interlocking / operation scheme indicated in Single Line diagram. The ACB shall have suitable arrangement for termination of busduct on incoming side and busbar connection at outgoing side as per single line diagram, complete with following for each incomer: 2 x 50kA, 2kVp surge arrester with suitable Fuse. 2 x R,Y,B,On,Off,Trip,Spring charge, Service position, test position, ready to close, trip circuit healthy LED indication lamp with 2A control MCB etc. as required. 2 x (16 window annunciation panel with trip, accept & reset options along with hooter) 2 x (3 nos. 2000/5A, CL-1, 15VA, ring type CT for 240V actuated numeric type APFC relay) 2 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of at least THD, KVARH KW, KWH, KVAR, PF, V, A, Hz with 15VA Class 1.0 CTs of required ratio)

-

-

-

... More
Incoming from 380 KVA DG Set - 1 nos.: 1 x 630 A, FP, 50 kA, Electrically draw out type ACB with inbuilt LSIG protection with microprocessor based release, shunt release (24V DC), inbuilt O/C & SC releases (Microprocessor based) having variable range with time lag facility to acheive discrimination. And required Interlocking between other incomer & Bus Coupler to be provided as per Interlocking / operation scheme indicated in Single Line diagram. The ACB shall have suitable arrangement for termination of cable on incoming side and busbar connection at outgoing side as per single line diagram, complete with following for incomer:

-

-

-

... More
Incoming from 160 KVA DG Set - 1 nos.: 1 x 400 A, FP, 50 kA, MCCB with microprocessor based release, shunt release (24V DC), having variable range with time lag facility to acheive discrimination with 400A FP Contractor. And required Interlocking between other incomer & Bus Coupler to be provided as per Interlocking / operation scheme indicated in Single Line diagram. The MCCB & Contractor shall have suitable arrangement for termination of cable on incoming side and busbar connection at outgoing side as per single line diagram, complete with following for incomer: 1 x R,Y,B,On,Off,Trip,Spring charge, Service position, test position, ready to close, LED indication lamp with 2A control MCB etc. as required. (DG-380 KVA) 1 x R,Y,B,On,Off,Trip,LED indication lamp with 2A control MCB etc. as required. (DG-160 KVA) 2 x (16 window annunciation panel with trip, accept & reset options along with hooter) 2 x (Auxiliary contactor 6 No + 6 NC, suitable for 24 V DC.) 2 x (start/stop, trip/reset, spring charge, emergency Push buttons, auto/manual switch, test, service, trip circuit healthy, DC healthy indications etc. as required) 2 x (230 V, Single Phase, 50 HZ, AC operated Battery Charger for DG Battery charging only, with Boost and trickle charging facility and protection from over charging the battery with voltmeter of range 0-50 Volts and Ammeter of range 0-50 Amp) 2 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of THD, KVARH KW, KWH, KVAR, PF, V, A, Hz with 15VA Class 1.0 CTs of required ratio) 2 x (IDMT based relay module with Ac inverse time overcurrent, instantaneous overcurrent relay, instantaneous earth fault relay, Overvoltage, undervoltage with dead band bypass feature, frequency, phase sequence, reverse power and earth fault relay along with CL-5P10, 15VA, CT of required ratio) 4 x (Restricted earth fault relay with required CTs) PLC based AMF, Auto Load Management as per Logic mentioned in Single Line Diagram, comprising required Auxiliary relays (24V DC, indication lights, Push button, Emergency stop, A/M position switch, Battery charger (230V A/C / 24V DC), Batteries, Digital I/O card, analogue card, 24V DC power supply as required. The Auto Load Management and AMF operation of DG Sets shall be carried out by power command center installed on each DG Set by DG Manufacturer however required coordination and provisions to achieve the same in coordination with PLC based Auto Load Management is included in the scope of work of Panel Manufacturer. Incoming from Solar Power Plant - 2 nos.: 2 x 400 A, FP, 50 kA, MCCB with On, Off, Trip and with inbuilt with microprocessor based release, shunt release (24V DC), having variable range with time lag facility to acheive discrimination. And required Interlocking between other incomer & Bus Coupler to be provided as per Interlocking / operation scheme indicated in Single Line diagram. Busbar (2 Set - 4P + E) : 2 & 3 Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 2500 A, 50 kA for 1 sec of required length and cross sectional area. Busbar (2 Set - 4P + E) : 1 & 4 Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 800 A, 50 kA for 1 sec of required length and cross sectional area.

-

-

-

... More
Buscoupler : 1 x 2000 A, FP, 50 kA, EDO type ACB with On, Off, Trip, Spring Charge indication and with inbuilt LSIG protection with microprocessor based release. Required Interlocking between other incomer & Bus Coupler to be provided as per Interlocking / operation scheme indicated in Single Line diagram. 2 x 630 A, FP, 50 kA, EDO type ACB with On, Off, Trip, Spring Charge indication and with inbuilt LSIG protection with microprocessor based release. Required Interlocking between other incomer & Bus Coupler to be provided as per Interlocking / operation scheme indicated in Single Line diagram. Note: All Incomer & Buscouplers shall be Mechanically & Electrically Interlocked, so that No supply from any two Incomers shall be parlleled

-

-

-

... More
Outgoings : 4 x 800 A, TPN, 50 kA, MDO type ACB with On, Off, Trip,R,Y,B indication and with inbuilt LSIG protection with microprocessor based release. 4 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 10VA Class 1.0 CTs of required ratio) 4 x 630 A, FP, 50kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with micoprocessor based release.. 4 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of at least KWH, KVAR, PF, V, A, Hz with 10VA Class 1.0 CTs of required ratio) 4 x 400 A, FP, 50kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with micoprocessor based release.. 4 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of at least KWH, KVAR, PF, V, A, Hz with 10VA Class 1.0 CTs of required ratio) 4 x 250 A, FP, 50kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with micoprocessor based release.. 4 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of at least KWH, KVAR, PF, V, A, Hz with 10VA Class 1.0 CTs of required ratio) 4 x 200 A, FP, 50kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with micoprocessor based release.. 4 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of at least KWH, KVAR, PF, V, A, Hz with 10VA Class 1.0 CTs of required ratio) 5 x 100 A, TPN, 50kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with micoprocessor based release.. 5 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of at least KWH, KVAR, PF, V, A, Hz with 10VA Class 1.0 CTs of required ratio)

-

-

-

... More
Main Panel as described above

1

6779755

6779755

... More
Capacitor panel (375kVAR)

-

-

-

... More
Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 800 A, FP, 50 kA, MDO type ACB with On, Off, Trip,R,Y,B indication and with inbuilt LSIG protection with microprocessor based release. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 10VA Class 1.0 CTs of required ratio) 1 x 12 numeric type stepped relay (APFCR) with 12 steps (each to be of 10/15/25/50/100 KVAR as required) for automatic power factor correction having facility to change the sequence of switching 'ON' the capacitor banks as required. The program of APFCR shall be re settable to enable sequance of ON/OFF of individual bank, so that the end unit of capacitor bank is not kept idle for long. Busbar (1 Set - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 1000 A, 36 kA for 1 sec of required length and cross sectional area. Outgoings : 4 x (125 Amp, 25kA, TP, MCCB (TM Based) + capacity ducty contact +7% detuned reactor + 50kVAr MPPH type heavy duy capacitor) 6 x (63 Amp, 25 kA, MCCB (TM Based) + capacity ducty contact + 7% detuned reactor + 25kVAr MPPH type heavy duy capacitor) 2 x (30 Amp, 25kA, TP, MCCB (TM Based) + capacity ducty contact + 7% detuned reactor + 10kVAr MPPH type heavy duy capacitor) 1 x (20 Amp, 25kA, TP, MCCB (TM Based) + capacity ducty contact + 7% detuned reactor + 5kVAr MPPH type heavy duy capacitor) Capacitor panel as described above

2

2935882

1467941

... More
Main Fire Panel

-

-

-

... More
Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 400A 4P Auto source transfer switch with complete neutral overlap suitable for cable on incoming & bus bar connection on outgoing side and to be connected as shown in SLD. 1 x 400 A, FP, 50 kA, MCCB with On, Off, Trip,R,Y,B indication and with inbuilt LSIG protection with microprocessor based release. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 10VA Class 1.0 CTs of required ratio) Busbar (1 Set - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 630 A, 36 kA for 1 sec of required length and cross sectional area. Outgoings : 2 x 250 A, TPN, 36kA, MCCB with trip setting as required. 1 x 160 A, TPN, 36kA, MCCB with trip setting as required. 2 x 125A, TPN, 36kA, MCCB with trip setting as required.

1

1540918

1540918

... More
Utility Panel Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 160 A, FP, 25kA, MCCB with trip settings as required. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Busbar (1 Set - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 200 A, 25 kA for 1 sec of required length and cross sectional area. 3 x 100A, FP, 25kA, MCCB with trip setting as required. 3 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) 2 x 63A, FP, 25kA, MCCB with trip setting as required. 2 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio)

1

334006

334006

... More
LNP-1 (LHS) (Typ. For LNP-1 (RHS) ) (Basement) Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 50kA, 2kVp surge arrester with suitable Fuse. 1 x 200 A, FP, 25kA, MCCB with trip settings as required. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Busbar (1 Set - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 200 A, 25 kA for 1 sec of required length and cross sectional area. Outgoings : 8 x 40 A, DP, 10KA, MCB "C Curve" 9 x 40 A / 63 A, FP, 10KA, MCB "C Curve"

2

308746

154373

... More
Ventilation Panel - 1 (Basement) Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 125 A, FP, 25kA, MCCB with trip settings as required. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Busbar (1 Set - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 200 A, 10 kA for 1 sec of required length and cross sectional area. Outgoings : 3 x 20 A, FP, 10kA, MCB "C Curve". 8 x 32 A, FP, 10kA, MCB "C Curve". Ventilation Panel - 1 (Basement) as described above

1

119288

119288

... More
Ventilation Panel - 2 (Terrace) Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 160 A, FP, 25kA, MCCB with trip settings as required. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Busbar (1 Set - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 200 A, 10 kA for 1 sec of required length and cross sectional area. Outgoings : 11 x 32 A, FP, 10kA, MCB "C Curve". 2 x 40 A, FP, 10kA, MCB "C Curve".

1

144549

144549

... More
L&P Panel - 2; 3 (RHS); 3; 4; 5; 6 (LHS) Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 50kA, 2kVp surge arrester with suitable Fuse. 1 x 125 A, FP, 25kA, MCCB with trip settings as required. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Busbar 1 Sets - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 150 A, 25 kA for 1 sec of required length and cross sectional area. Outgoings : 9 x 40 A, DP, 10kA, MCB "C Curve" 8 x 40 A / 63 A, FP, 10kA, MCB "C Curve"

6

976758

162793

... More
L&P Panel - 3; 4; 5; 6 (RHS) Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 50kA, 2kVp surge arrester with suitable Fuse. 1 x 160 A, FP, 25kA, MCCB with trip settings as required. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Busbar 1 Sets - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 200 A, 25 kA for 1 sec of required length and cross sectional area. Outgoings : 15 x 40 A, DP, 10kA, MCB "C Curve" 9 x 40 A / 63 A, FP, 10kA, MCB "C Curve"

4

684856

171214

... More
L&P Panel - 7 (LHS) & 7 ( RHS) Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 50kA, 2kVp surge arrester with suitable Fuse. 1 x 200 A, FP, 25kA, MCCB with trip settings as required. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Busbar 1 Sets - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 200 A, 25 kA for 1 sec of required length and cross sectional area. Outgoings : 3 x 32 A, FP, 10kA, MCB "C Curve" 9 x 40 A / 63 A, FP, 10kA, MCB "C Curve"

2

328394

164197

... More
Sump Pump Panel (Basement) Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 25kA, 2kVp surge arrester with suitable Fuse. 1 x 100 A, FP, 25kA, MCCB with trip settings as required. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Busbar 1 Set - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 100 A, 25 kA for 1 sec of required length and cross sectional area. Outgoings : 8 x 25 A / 32 A, FP, 10kA, MCB "C Curve".

1

123498

123498

... More
Lift Panel -1 (Typ. For Lift Panel-2) Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 25kA, 2kVp surge arrester with suitable Fuse. 1 x 125 A 4P Auto source transfer switch with complete neutral overlap 1 x 125 A, FP, 25kA, MCCB with trip settings as required. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Busbar 1 Set - TPN + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 150 A, 25 kA for 1 sec of required length and cross sectional area. Outgoings : 3 x 63 A, ELMCB, 2 x 32 A, DP, 10kA, MCB "C Curve".

2

1268662

634331

... More
UPS Input Panel Incomer - 02 nos.: 2 sets- R,Y,B LED indication lamp with 2A control MCB. 2 x 25kA, 2kVp surge arrester with suitable Fuse. 3 x 250 A, FP, 25kA, MCCB with trip settings as required. 3 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of THD, KVARH, KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio)

1

189458

189458

... More
UPS output Panel -1 Incomer - 02 nos.: R,Y,B LED indication lamp with 2A control MCB. 2 x 25kA, 2kVp surge arrester with suitable Fuse. 3 x 250 A, FP, 25kA, MCCB with trip settings as required. 3 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of THD, KVARH, KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Outgoings : 2 x 125 A, FP, 25kA, MCCB with trip setting as required. 10 x 100 A, FP, 25kA, MCCB with trip setting as required. 12 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio)

1

867293

867293

... More
USDB-1 (Power) - Basement ( Typ. For each Floor) Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 50kA, 2kVp surge arrester with suitable Fuse. 1 x 125 A, FP, 25kA, MCCB with trip settings as required. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Busbar - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 150 A, 25 kA for 1 sec of required length and cross sectional area. Outgoings : 3 x 32 A, DP, 10kA, MCB "D Curve" 9 x 40 A / 63 A, FP, 10kA, MCB "D Curve"

1

154373

154373

... More
USDB-2 (Power) & 3 - Gr. Floor ( Typ. For each Floor) Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 50kA, 2kVp surge arrester with suitable Fuse. 1 x 100 A, FP, 25kA, MCCB with trip settings as required. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Busbar - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 150 A, 25 kA for 1 sec of required length and cross sectional area. Outgoings : 9 x 40 A, DP, 10kA, MCB "D Curve"

2

221736

110868

... More
USDB-4 (Power); ( Typ. For 5; 6; 7; 8 & 9 ) Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 50kA, 2kVp surge arrester with suitable Fuse. 1 x 100 A, FP, 25kA, MCCB with trip settings as required. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Busbar - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 150 A, 25 kA for 1 sec of required length and cross sectional area. Outgoings : 5 x 40 A, DP, 10kA, MCB "D Curve" 4 x 40A / 63A, DP, 10kA, MCB "D Curve"

6

665208

110868

... More
UPS OUTPUT Panel-2 Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 50kA, 2kVp surge arrester with suitable Fuse. 1 x 200 A, FP, 25kA, MCCB with trip settings as required. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Busbar 1 Sets - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 200 A, 25 kA for 1 sec of required length and cross sectional area. Outgoings : 9 x 40 A / 63 A, FP, 10kA, MCB "D Curve"

1

150163

150163

... More
UPSDB Panel -1 (Lighting); ( Typ. For 5; 6; 7; 8 & 9 ) Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 50kA, 2kVp surge arrester with suitable Fuse. 1 x 63 A, FP, 10kA, MCB "D Curve" 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Busbar - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 100 A, 25 kA for 1 sec of required length and cross sectional area. Outgoings : 12 x 32A, DP, 10kA, MCB "D Curve"

6

513642

85607

... More
HVAC Panel-1 (Typ. For HVAC Panel-2) Incomer : R,Y,B LED indication lamp with 2A control MCB. 1 x 50kA, 2kVp surge arrester with suitable Fuse. 1 x 630 A, FP, 25kA, MCCB with trip settings as required. 1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VA Class 1.0 CTs of required ratio) Busbar 1 Sets - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 800 A, 25 kA for 1 sec of required length and cross sectional area. Outgoings : 12 x 80 A, FP, 25kA, MCCB with 63A FP ELCB (100mA) 4 x 40A / 63A, FP, 10kA, MCB "C Curve" with 63A FP ELCB (100mA)

2

1254628

627314

... More
CHAPTER 6 : UPS Supplying, installation, testing and commissioning of 3x120 KVA online double conversion fully microprocessor based ,indoor type, compact UPS system with IGBT based PWM technology to achieve THD 3% and input power factor of greater than 0.95 at 50% loading,suitable for three phase AC input voltage 380 V to 440 V, 50 Hz +3% / - 3 % and three phase AC output voltage 415 ± 1% volts & frequency 50 ± 0.5 Hz suitable for operating in PRS mode, with all componentsas required and as per technical specification. The 03 no. UPS are operating in parallel redundant mode so that if any one UPS fails the other two can take care of 100% load. Each UPS unit shall be comprising of the following: a. 125% rated Rectifier cum charger unit +100% rated Invertor, Integrated in UPS module b. 100% rated Galvanic isolation transformers of K-13 Delta/Zigzag type copper winding and auto softstart module, Datson make for isolation of input neutral with output neutral ,to be installed after UPS as shown in drawing enclosed c. 100% rated Inbuilt static switch at the invertor output + 2 Nos. 100% rated Inbuilt static switches at the static bypass line. d. 100% rated Inbuilt Maintenance Bypass. e. Web-enabled Monitoring and Management through SNMP protocols for multi-OS environments. The quoted rates shall also include but not limited to following for each unit: i. Supplying, unloading, installing , testing and commissioning of necessary VRLA batteries of suitable size having 30 minutes back up time to 3x120 KVA UPS for full load (20% aging factor to be considered), Note : Concerning vendor needs to furnish the battery sizing calculations at the time of GA approval and battery size has to be as per the approved GA drawing. ii. Supply, unloading, installation, testing & commissioning of matching cabinet/open racks to house above mentioned batteries for 3x120 KVA UPS system along with suitable size interconnecting cable (for UPS to Battery and battery to battery), MCCB etc. complete as required & as per specifications. Supply,installation, testing and commissioning of UPS monitoring software suitable for RJ-45 communication and capable of giving pop up messages for all alarms received from UPS. It shall be capable of the following:- a. Giving notifications like e-mail, paging notification, broadcast notification, battery replacement notification, run event-based scripts. B. Event logging, data logging and action logging (with date, time, description of fault and event). C. Run the battery diagnostic test. D. Automated unattended shutdown of computers. E. Local notification through audible alarm. F. Software should support : Latest version of Microsoft Windows/Server, AIX, HP-UX, Sun Solaris, Linux, Novell Netware, MAC

1

10861104

10861104

... More
Supplying, installation, testing and commissioning of 2x30 KVA online double conversion fully microprocessor based ,indoor type, compact UPS system of mentioned rating with IGBT based PWM technology to achieve THD 3% and input power factor of greater than 0.95 at 50% loading,suitable for three phase AC input voltage 380 V to 440 V, 50 Hz +3% / - 3 % and three phase AC output voltage 415 ± 1% volts & frequency 50 ± 0.5 Hz with all components as mentioned in BOQ, specifications and schedule, complete as required and as per technical specification. Each UPS unit shall be comprising of the following: 125% rated Rectifier cum charger unit +100% rated Invertor, Integrated in UPS module 100% rated inbuilt isolation transformer 100% rated Inbuilt static switch at the invertor output + 2 Nos. 100% rated Inbuilt static switches at the static bypass line. 100% rated Inbuilt Maintenance Bypass. Web-enabled Monitoring and Management through SNMP protocols for multi-OS environments. The quoted rates shall also include but not limited to following for each unit: Supplying, unloading, installing , testing and commissioning of necessary VRLA batteries of suitable size having 30 minutes back up time to 2x30KVA UPS for full load (20% aging factor to be considered), Note : Concerning vendor needs to furnish the battery sizing calculations at the time of GA approval and battery size has to be as per the approved GA drawing. Supply, unloading, installation, testing & commissioning of matching cabinet/open racks to house above mentioned batteries for 2x30 KVA UPS system along with suitable size interconnecting cable (for UPS to Battery and battery to battery), MCCB etc. complete as required & as per specifications. Supply,installation, testing and commissioning of UPS monitoring software suitable for RJ-45 communication and capable of giving pop up messages for all alarms received from UPS. It shall be capable of the following:- Giving notifications like e-mail, paging notification, broadcast notification, battery replacement notification, run event-based scripts. Event logging, data logging and action logging (with date, time, description of fault and event). Run the battery diagnostic test. Automated unattended shutdown of computers. Local notification through audible alarm. F. Software should support : Latest version of Microsoft Windows/Server, AIX, HP-UX, Sun Solaris, Linux, Novell Netware, MAC

1

2283369

2283369

... More
CHAPTER 7: LT CABLES & TERMINATIONS Supplying following 1.1kV grade, XLPE insulated, FRLS type armoured/unarmoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required.

-

-

-

... More
3.5C X 300 Sqmm A2XFY.

1590

4102200

2580

... More
3.5C X 240 Sqmm A2XFY.

2160

4579200

2120

... More
3.5C X 185 Sqmm A2XFY.

350

583100

1666

... More
3.5C X 150 Sqmm A2XFY.

300

394800

1316

... More
3.5C X 120 Sqmm A2XFY.

50

56550

1131

... More
3.5C X 95 Sqmm A2XFY.

600

545400

909

... More
3.5C X 70 Sqmm A2XFY.

275

200200

728

... More
3.5C X 50 Sqmm A2XFY.

475

257450

542

... More
3.5C X 35 Sqmm A2XFY.

2230

912070

409

... More
3.5C X 25 Sqmm A2XFY.

3135

1037685

331

... More
4C X 16 Sqmm A2XWY.

3860

1046060

271

... More
4C X 10 Sqmm A2XWY.

4200

961800

229

... More
4C X 6 Sqmm A2XWY.

2515

490425

195

... More
4C X 4 Sqmm A2XWY.

1440

230400

160

... More
3C X 16 Sqmm A2XWY.

750

165000

220

... More
3C X 10 Sqmm A2XWY.

1090

231080

212

... More
3C X 6 Sqmm A2XWY.

1540

260260

169

... More
3C X 4 Sqmm A2XWY.

750

104250

139

... More
2C X 10 sqmm A2XWY

300

62400

208

... More
2C X 6 sqmm A2XWY

1200

176400

147

... More
1C X 95 sqmm copper cable for ups work

100

90000

900

... More
1C X 70 sqmm A2XY

100

20800

208

... More
1C X 50 sqmm A2XY

100

15700

157

... More
1C X 25 sqmm A2XY

200

20000

100

... More
Supplying following 1.1kV grade, XLPE insulated, FRLS type control cables,suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required.

-

-

-

... More
2C X 2.5 sqmm copper conductor

280

47320

169

... More
4C X 2.5 sqmm copper conductor

280

72800

260

... More
7C X 2.5 sqmm copper conductor

140

58660

419

... More
10C X 2.5 sqmm copper conductor

450

247500

550

... More
19C X 2.5 sqmm copper conductor

140

138320

988

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Up to 35 sqmm

1200

464400

387

... More
Above 185 sqmm and up to 400 sqmm

100

47400

474

... More
Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Up to 35 sqmm

640

172160

269

... More
Above 185 sqmm and up to 400 sqmm

1390

494840

356

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1kV grade of following size in the existing RCC trench / Hume pipe / pipe complete as required.

-

-

-

... More
Up to 35 sqmm

600

22200

37

... More
Above 185 sqmm and up to 400 sqmm

790

105860

134

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

22050

617400

28

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

1650

74250

45

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

700

44100

63

... More
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

1480

170200

115

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.

-

-

-

... More
3½ X 300 sq. mm (70 mm)

62

74090

1195

... More
3½ X 240 sq. mm (62 mm)

30

30810

1027

... More
3½ X 185 sq. mm (57 mm)

60

52500

875

... More
3½ X 150 sq. mm (50 mm)

12

8364

697

... More
3½ X 120 sq. mm (45 mm)

4

2452

613

... More
3½ X 95 sq. mm (45 mm)

12

7056

588

... More
3½ X 70 sq. mm (38mm)

14

6552

468

... More
3½ X 50 sq. mm (35 mm)

20

8260

413

... More
4 X 35 sq. mm (32 mm)

40

14800

370

... More
4 X 25 sq. mm (28 mm)

74

23310

315

... More
4C X 16 Sqmm (28mm)

172

53148

309

... More
4C X 10 Sqmm (25mm)/ 4C X 6 Sqmm

182

48958

269

... More
3C X 16 Sqmm (25mm)

134

34438

257

... More
3C X 10 Sqmm (22mm)

176

45232

257

... More
2C X 6 sqmm (19mm) /4C X 4 Sqmm / 3C X 6 Sqmm

406

97440

240

... More
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required.

-

-

-

... More
1C X 95 sqmm 2XWY

20

5620

281

... More
1C X 70 sqmm 2XWY

4

1012

253

... More
1C X 50 sqmm 2XWY

6

1266

211

... More
1C X 25 sqmm 2XWY

4

676

169

... More
2C X 2.5 sqmm copper conductor

8

1408

176

... More
4C X 2.5 sqmm copper conductor

8

1576

197

... More
7C X 2.5 sqmm copper conductor

4

1124

281

... More
10C X 2.5 sqmm copper conductor

8

3600

450

... More
19C X 2.5 sqmm copper conductor

4

3088

772

... More
CHAPTER 8: CABLES MANAGEMENT

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width x 50 mm depth x 1.6 mm thickness

70

46830

669

... More
150 mm width x 50 mm depth x 1.6 mm thickness

350

250600

716

... More
300 mm width x 50 mm depth x 1.6 mm thickness

770

741510

963

... More
600 mm width x 50 mm depth x 2 mm thickness

720

1288800

1790

... More
900 mm width x 75 mm depth x 2 mm thickness

400

1044800

2612

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable trays "bends" with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

28

32452

1159

... More
150 mm width X 50 mm depth X 1.6 mm thickness

14

17780

1270

... More
300 mm width X 50 mm depth X 1.6 mm thickness

42

77784

1852

... More
600 mm width x 50 mm depth x 2 mm thickness

24

90576

3774

... More
900 mm width x 75 mm depth x 2 mm thickness

8

45096

5637

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable trays "Tee" with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

14

18578

1327

... More
150 mm width X 50 mm depth X 1.6 mm thickness

28

38724

1383

... More
300 mm width X 50 mm depth X 1.6 mm thickness

42

90552

2156

... More
600 mm width x 50 mm depth x 2 mm thickness

36

160056

4446

... More
900 mm width x 75 mm depth x 2 mm thickness

4

26592

6648

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable trays "Cross Member" with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

2

2654

1327

... More
150 mm width X 50 mm depth X 1.6 mm thickness

12

16596

1383

... More
300 mm width X 50 mm depth X 1.6 mm thickness

12

28392

2366

... More
600 mm width x 50 mm depth x 2 mm thickness

12

53520

4460

... More
900 mm width x 75 mm depth x 2 mm thickness

4

19640

4910

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling withG.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

24

46104

1921

... More
300 mm width X 50 mm depth X 1.6 mm thickness

14

39522

2823

... More
600 mm width x 50 mm depth x 2 mm thickness

12

61740

5145

... More
900 mm width x 75 mm depth x 2 mm thickness

2

15018

7509

... More
Supply, Installation testing and commissioning of MS powder coated, metallic adaptable raceway system, non compartmentalize, single sections of required sizes with cover complete as per drawing of below mentioned sizes suitable for passing through walls, ceiling and floors as per the layout, suitable for FRLS wires/unarmoured cables and extra low voltage cables for data /AV/telephone. along with Z- section, hole with thread for cover screw, coupler plate, cover, fly cover, tees, supports etc. as required but excluding the cost of junction box, complete with G.I. hangers to support in ceiling/ or fixed in the floor complete with cutting chases in floors, grouting in floors and making good of the same as required.

-

-

-

... More
100 mm x 50 mm x 1.6 mm

570

340290

597

... More
200 mm x 50 mm x 1.6 mm

810

711180

878

... More
300 mm x 50 mm x 2 mm

1060

1525340

1439

... More
Fabricating Installation testing and commissioning 2 mm thick M.S. powder coated, sheet steel 5 sided junction boxes along with 3 mm thick cover, rubber gasket between the cover and the junction box, steel screws and all other accessories complete as required.

-

-

-

... More
Junction box suitable for 100 mm x 50 mm x 1.6 mm raceway

86

48332

562

... More
Junction box suitable for 200 mm x 50 mm x 1.6 mm raceway

72

60696

843

... More
Junction box suitable for 300 mm x 50 mm x 2 mm raceway

96

117888

1228

... More
CHAPTER 9: DISTRIBUTION BOARD

-

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 way, Double door

39

86034

2206

... More
8 way, Double door

98

252154

2573

... More
12 way, Double door

54

125010

2315

... More
16 way, Double door

30

94230

3141

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
4 way (4 + 12), Double door

1

4091

4091

... More
6 way (4 + 18), Double door

7

34818

4974

... More
8 way (4 + 24), Double door

64

381888

5967

... More
Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
4 way Double door (8 + 12)

6

45072

7512

... More
8 way Double door (8 + 24)

10

101650

10165

... More
12 way Double door (8 + 36)

2

25666

12833

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

2772

709632

256

... More
Double pole

113

74128

656

... More
Triple pole

78

78546

1007

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

300

2100

7

... More
Supplying and fixing following double pole, 240 V, Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
40 A

54

23490

435

... More
63 A

30

15810

527

... More
Supplying and fixing following rating, four pole 415 volts, Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
40A

7

6790

970

... More
63A

70

72380

1034

... More
100A

26

31902

1227

... More
Supplying and fixing following rating, double pole (single phase & neutral), 240 V, Residual current circuit breaker (RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
25A

113

229164

2028

... More
40A

75

198150

2642

... More
63A

318

865596

2722

... More
Supplying and fixing following rating, Four pole (three phase & neutral), 415 V, Residual current circuit breaker (RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
25 amps

2

5172

2586

... More
40 amps

4

12752

3188

... More
63 amps

4

11488

2872

... More
Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.

12

14028

1169

... More
Supplying and fixing TP sheet steel enclosure on surface/ recessed along with 16/25/32 A, 415 V “C” curve TP MCB complete with connections, testing and commissioning etc. as required.

4

6368

1592

... More
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in the cubical panel, making connections etc. as required. (for VTPN DB)

-

-

-

... More
100 A, 16kA, TP MCCB

10

37770

3777

... More
125 A, 16kA, TP MCCB

2

9642

4821

... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

80

129680

1621

... More
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

60

155400

2590

... More
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

44

180708

4107

... More
Supplying and fixing 32 amp, 240 Volts, SPN industrial type socket outlet with 2 pole and earth, enclosed plug top , in IP-65 enclosure, on surface or in recess, with cover for socket outlet, IK-08, with interlocking switch and complete with connections , testing commissioning etc. as required.

6

60060

10010

... More
Supplying and fixing 63 amp, 415 Volts, weatherproof TPN industrial type, IP 65 outlet with 4 pole and earth within polycarbonate enclosure, plug top on surface or in recess, with cover for socket outlet ,IK-08, with interlocking switch and complete with connections , testing commissioning etc. as required.

2

35324

17662

... More
CHAPTER 10: WIRING

-

-

-

... More
Wiring in medium class PVC Conduit: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required

-

-

-

... More
Group C

1500

2200500

1467

... More
Wiring in medium class PVC Conduit: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class Partially laid PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required

-

-

-

... More
Group C

500

475000

950

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group C

2620

2866280

1094

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required

36

56232

1562

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

3700

1235800

334

... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

1900

1020300

537

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire.

13500

3145500

233

... More
2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire.

3000

825000

275

... More
2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire

3700

1235800

334

... More
2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire

1900

834100

439

... More
2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire

1960

1117200

570

... More
2 x 16 sq.mm. + 1 x 6 sq.mm. earth wire

810

625320

772

... More
4 x 2.5 sq.mm. + 2 x 2.5 sq.mm. earth wire.

1000

410000

410

... More
4 x 4 sq.mm. + 2 x 4 sq.mm. earth wire.

2000

1074000

537

... More
4 x 6 sq.mm. + 2 x 6 sq.mm. earth wire

1500

1131000

754

... More
4 x 10 sq.mm. + 2 x 6 sq.mm. earth wire

300

301500

1005

... More
4 x 16 sq.mm. + 2 x 6 sq.mm. earth wire

300

409500

1365

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20 mm

3000

384000

128

... More
25 mm

3000

435000

145

... More
32 mm

1000

184000

184

... More
Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required.

-

-

-

... More
5/6 amps switch

2680

276040

103

... More
15/16 amp switch

950

148200

156

... More
3 pin 5/6 amp socket outlet

4000

488000

122

... More
6 pin 15/16 amp socket outlet

950

187150

197

... More
Telephone socket outlet

270

39960

148

... More
TV antenna socket outlet

30

4440

148

... More
Bell Push

30

4200

140

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

810

298890

369

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

1320

52800

40

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.

-

-

-

... More
1 or 2 Module

1110

147630

133

... More
3 Module

2320

350320

151

... More
4 Module

10

1580

158

... More
6 Module

1320

240240

182

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

100

47700

477

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

100

58600

586

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

20

1740

87

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.

100

9900

99

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

2000

94000

47

... More
Installation of exhaust fan in the existing opening , including making good the damage, connection, testing commissioning etc. as required.

-

-

-

... More
(a): Up to 450mm sweep

20

9000

450

... More
Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes.

20

4140

207

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).

100

67600

676

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.

50

36350

727

... More
Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

810

274590

339

... More
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

810

42120

52

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20 mm

1600

204800

128

... More
25 mm

4800

696000

145

... More
32 mm

800

147200

184

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

810

150012

185.2

... More
CHAPTER 11: EARTHING & LIGHTNING PROTECTION

-

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.

35

239925

6855

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

30

224160

7472

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

20

276760

13838

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

8000

560000

70

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

5920

1444480

244

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

300

211800

706

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

200

310200

1551

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

244

283528

1162

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

6

3108

518

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor and external lighting complete as required. (For Horizontal run)

1200

151200

126

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)

682

134354

197

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

35

4235

121

... More
CHAPTER 12: FIXTURES & FANS Preamble for Supply of Light fixtures LED 2x2 luminaire/ 4' Linear Luminiare All LED 2x2 luminaire/ 4' Linear Luminiare shall be with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have a color consistency SDCM 5, CRI 80 and CCT of both 5700K/ 6500K, compliant with IP20 and IK02 classification. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.95 and THD 10%.  The fixture design should comply with Minimum Internal Surge Protection 4.0 KV & with EMC / EMI compliance along with BIS certification for LED Driver & Luminaire. The fixture should comply with the parameters as per IS10322. The LED driver of luminiare shall comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. All recess LED Fitting shall have pressure die cast Al. / LM 6 Alloy housing LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) Luminiare shall be suitable for 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K (SDCM5), CRI 80, PF 0.95, Min working temp range - 0°C Ta 45°C, an operating Voltage Range of 130 - 320 VAC. The fixture design should comply with Minimum Internal Surge Protection 2.5KV ( 4.0 KV for flood lights) & with EMC / EMI compliance along with BIS certification for LED Driver & Luminaire. The LED driver of luminiare shall comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Luminaire manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer. LED Down Lighter/ LED Bulkhead / LED Flood Lights/ Street Light All recess LED Fitting shall have pressure die cast Al. / LM 6 Alloy housing LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) Luminiare shall be suitable for 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K (SDCM5), CRI 80, PF 0.95, Min working temp range - 0°C Ta 45°C, an operating Voltage Range of 130 - 320 VAC. The fixture design should comply with Minimum Internal Surge Protection 2.5KV ( 4.0 KV for flood lights) & with EMC / EMI compliance along with BIS certification for LED Driver & Luminaire. The LED driver of luminiare shall comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Luminaire manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer.

-

-

-

... More
Supplying, installation, testing & commissioning of 2' x 2' 36-40W recess mounting type LED luminaire having CRCA housing suitable with fully diffused diffuser, a color consistency SDCM 5, CRI 80 and CCT of 5700K. Luminaire shall be designed to emit at least 4000 lumens and an outstanding backlit solution efficacy of at least 100 lumen/watt and maximum system wattage of 40 Watts. The electronic driver used shall have a power factor 0.95 and THD 10%. Similar to Philips RC380B G6 LED42S-5700 G6 L60W60 PSU OD.

1520

6840000

4500

... More
Supplying, installation, testing & commissioning of 2' x 2' 36-40W surface mounting type LED luminaire having CRCA housing suitable with fully diffused diffuser, a color consistency SDCM 5, CRI 80 and CCT of both 5700K. Luminaire shall be designed to emit at least 4000 lumens and an outstanding backlit solution efficacy of at least 100 lumen/watt and maximum system wattage of 40 Watts. The electronic driver used shall have a power factor 0.95 and THD 10%. Similar to Philips RC380B G6 LED42S-5700 G6 L60W60 PSU OD with surface mounting frame.

290

1015000

3500

... More
Supplying, installation, testing & commissioning of 15-18W LED indoor surface mounted downlighter having CRCA housing & polycarbonate cover with diffused optics, CRI 80 and CCT of 6500K. The fixture should have a minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 1800 lumens. The electronic driver used shall have a power factor 0.95 , THD 10%.  Similar to Philips SM251C LED20S- 6500 PSU WH.

272

489600

1800

... More
Supplying, installation, testing & commissioning of 10-12W LED indoor recessed downlighter having CRCA housing & polycarbonate cover with diffused optics, CRI 80 and CCT of 6500K. The fixture should have a minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 1200 lumens. The electronic driver used shall have a power factor 0.95 , THD 10%.  Similar to Philips DN296B LED12S-6500 PSE WH.

530

450500

850

... More
Supplying, installation, testing & commissioning of 18-20W LED indoor recessed downlighter having CRCA housing & polycarbonate cover with diffused optics, CRI 80 and CCT of 6500K. The fixture should have a minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 2000 lumens. The electronic driver used shall have a power factor 0.95 , THD 10%.  Similar to Philips DN296B LED20S-6500 PSE WH.

734

513800

700

... More
Supplying, installation, testing & commissioning of 4 feet 26-28W surface mounted LED batten made of CRCA housing with high efficiency reflector, should have minimum efficacy at System level (Not Chip Level) 120 lm/W with Minimum system Lumens 3200, CRI 80, PF 0.95 & THD10%, an operating Voltage Range of 130 - 320 VAC. The driver should be easily maintainable and replaceable from the top of the batten. The luminaire should be flicker free (Ripple5%). Fixture Similar to Philips BN308C LED40S-6500 L120 PSU WH.

102

183600

1800

... More
Supplying, installation, testing & commissioning of 4 feet 16-18W surface mounted LED batten made of CRCA housing with high efficiency reflector, should have minimum efficacy at System level (Not Chip Level) 120 lm/W with Minimum system Lumens 2100, CRI 80, PF 0.95 & THD10%, an operating Voltage Range of 130 - 320 VAC. The driver should be easily maintainable and replaceable from the top of the batten. The luminaire should be flicker free (Ripple5%). Fixture Similar to Philips BN308C LED20S-6500 L120 PSU WH.

148

103600

700

... More
Supplying, installation, testing & commissioning of 9-10W Bulkhead made of pressure die cast aluminum housing with Polycarbonate Diffuser having minimum efficacy at System level (Not Chip Level) 100lumens/watt with minimum 1100 Lumens, CCT up to 6500, CRI 80, PF 0.90. Similar to Philips WT202W LED10S CW PSU S3 PC.

24

19200

800

... More
Supply of LED based 75-80W Flood light, housing made up of pressure die cast aluminum, minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 8000 lumens, CRI of minimum 70; Color temparaure should be of 5700K, Ingress Protection of IP66 (lamp and gear Compartment both), mechanical impact resistance of IK-07. The fixture driver should have an operating voltage range of 140-270 V, surge protection of =4KV, PF 0.9 and THD10%. The LED driver should have Fixed output, High Cut @325V , capable to withstand 440V for 8 Hrs and auto restart feature. Similar to Philips BVP192 LED82 CW HO NB FG GR PSU

32

256000

8000

... More
Supply of LED based 65-70W Street light fitting, housing made up of pressure die cast LM 6 Alloy/ Antidust exposed Lens, minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 7000 lumens, CRI of minimum 70; Color temparaure should be of 5700K, Ingress Protection of IP66 (lamp and gear Compartment both), mechanical impact resistance of IK-08. The fixture driver should have an operating voltage range of 140-270 V, surge protection of =4KV, PF 0.9 and THD10%. The LED driver should have Fixed output, High Cut @325V , capable to withstand 440V for 8 Hrs and and Auto Restart function should also be available within the fixture. Similar to Philips BRP062 LED 84 CW SLC S1 PSU

20

130000

6500

... More
Supply of LED based 30-35W Street light fitting, housing made up of pressure die cast LM 6 Alloy/ Antidust exposed Lens, minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 3500 lumens, CRI of minimum 70; Color temparaure should be of 5700K, Ingress Protection of IP66 (lamp and gear Compartment both), mechanical impact resistance of IK-08. The fixture driver should have an operating voltage range of 140-270 V, surge protection of =4KV, PF 0.9 and THD10%. The LED driver should have Fixed output, High Cut @325V , capable to withstand 440V for 8 Hrs and and Auto Restart function should also be available within the fixture. Similar to Philips BRP046 LED 39 CW MR S1 PSU GR

40

120000

3000

... More
Supply & Installation of 7.0 mtr. high GI octagonal street light pole 3 mm wall thickness having Top dia - 70 mm, Bottom Dia - 135 mm along with base plate of size 300 mm x 300 mm x 12 mm thick, Single Arm Bracket 1 m Long with 48.3 OD GI Pipe, suitable for mounting of 1 no. light fixture. Pole should be finished with adaquate size flush door with openable chained cover in lower section with proper strengthning of cutout of door opening including necessary rubber gasket with two coats of pu paint of approved shade, supplying & fixing of suitable size SP MCB , neutral link, earth stud, heavy duty connector (suitable for upto 16 sq.mm terminations). Note : 1. The pole shall be either of same make as that of street light fixture or equivalent 2. The pole shall be installed in cement concrete 1:3:6 (1 cement : 3 Coarse sand : 6 graded stone aggregate of 40 mm nominal size) foundation minimum size of 0.21 cum including excavation and refilling etc. as required. Providing and fixing Foundation Bolt- M16 x 450 mm.(4Nos.) with nuts and and washer complete as required.

20

320000

16000

... More
Supply & Installation of 3.0 mtr. long GI street light pole 4.5 mm wal thickness having 114 mm outer uniform dia. and 60.3 mm dia., 3.6 mm thick 100 mm long coller along with base plate of size 300 mm x 300 mm x 12 mm thick, suitable for mounting of 1 no. light fixture. Pole should be finished with adaquate size flush door with openable chained cover in lower section with proper strengthning of cutout of door opening including necessary rubber gasket with two coats of pu paint of approved shade, supplying & fixing of suitable size SP MCB , neutral link, earth stud, heavy duty connector (suitable for 16 sq.mm terminations) complete as required. Note : 1. The pole shall be either of same make as that of street light fixture or equivalent 2. The pole shall be installed in cement concrete 1:3:6 (1 cement : 3 Coarse sand : 6 graded stone aggregate of 40 mm nominal size) foundation minimum size of 0.21 cum including excavation and refilling etc. as required. Providing and fixing Foundation Bolt- M16 x 450 mm.(4Nos.) with nuts and and washer complete as required.

40

360000

9000

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required

-

-

-

... More
1200 mm sweep ceiling fan with Industrial Regulator100 Watt 2M

814

2222220

2730

... More
Supply of 300mm size, 900 rpm heavy duty exhaust fan suitable for 230V, 50 Hz AC including modifying and finishing for hole/opening for the size of fan, MS louver/ shutter complete with frame for Ex.fan including its connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge.

16

70528

4408

... More
Supply of 450mm size, 900 rpm heavy duty exhaust fan suitable for 230V, 50 Hz AC including modifying and finishing for hole/opening for the size of fan, MS louver/ shutter complete with frame for Ex.fan including its connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge.

2

9776

4888

... More
CHAPTER 13: CIVIL WORKS

-

-

-

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.

-

-

-

... More
63 mm dia (OD-63 mm & ID-51 mm nominal)

100

12700

127

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

70

17360

248

... More
200 mm dia (OD-200 mm & ID-175 mm nominal)

30

16440

548

... More
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc. in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 meter.

240

156960

654

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.

-

-

-

... More
150 mm dia

90

65160

724

... More
250 mm dia

60

58500

975

... More
300 mm dia

150

171000

1140

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
Inside size 90x80 cm and 45 cm deep including C.I. Cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

6

70122

11687.1

... More
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 910x555 mm, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) :

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

12

292870

24405.9

... More
Extra for depth for manholes :

-

-

-

... More
Size 90X80 cm

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

8127

8127.45

... More
Size 120x90 cm

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

19488

9744.25

... More
Providing & fixing in position 1000 mm wide , Electrical Insulating Rubber Mats as per IS 15652:2006, 6 mm thick, suitable up to 11 KV , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top)

10

9130

913

... More
Providing & fixing in position 1000 mm wide , Electrical Insulating Rubber Mats as per IS 15652:2006, 2 mm thick, suitable up to 1.1 KV , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top)

60

37920

632

... More
Supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 Sq Metre )

4

4492

1123

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

10

2690

269

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

20

10160

508

... More
CHAPTER-14 : DATA AND NETWORKING

-

-

-

... More
Supply, Installation, Testing & Commissioning of Cat-6A Mounting Cords 7 Feet for Data as per given Specification etc. complete as required

1320

826320

626

... More
Supply, Installation, Testing & Commissioning of Cat-6A Mounting Cords 4 Feet for Data Jack Panel end as per given Specification etc. complete as required

1320

658680

499

... More
Supply, Installation, Testing & Commissioning of Cat-6A, 24 Port Jack Panel for data as per given Specification etc. complete as required

60

1136760

18946

... More
Supply, Installation, Testing & Commissioning of Cat-6A Mounting Cords 4 Feet for Voice Jack Panel end as per given Specification etc. complete as required

262

130738

499

... More
Supply, Installation, Testing & Commissioning of Cat-6A 24 Port Jack Panel for Voice Field as per given Specification etc. complete as required

12

227352

18946

... More
Supply, Installation, Testing & Commissioning of Cat-6A 24 Port Jack Panel for Voice Field & Resource as per given Specification etc. complete as required

12

227352

18946

... More
Supply, Installation, Testing & Commissioning of 15 U Wall Mount Rack as per given Specification etc. complete as required

3

68205

22735

... More
Supply, Installation, Testing & Commissioning of 9 U Wall Mount Rack as per given Specification etc. complete as required

3

45471

15157

... More
Supply, Installation, Testing & Commissioning of 1 U PVC Cable Manager as per given Specification etc. complete as required

90

108000

1200

... More
Supply, Installation, Testing & Commissioning of 6 socket PDU as per given Specification etc. complete as required

6

11370

1895

... More
Supply, Installation, Testing & Commissioning of Mounting Hardware pack of 10pcs as per given Specification etc. complete as required

12

12132

1011

... More
Supply, Installation, Testing & Commissioning of 10 Pair Krone Module as per given Specification etc. complete as required

110

62590

569

... More
Supply, Installation, Testing & Commissioning of 300 Pair MDF Box with Mounting Frame as per given Specification etc. complete as required

1

19704

19704

... More
Supply, Installation, Testing & Commissioning of 100 Pair MDF Box with Mounting Frame as per given Specification etc. complete as required

1

6947

6947

... More
Supply, Installation, Testing & Commissioning of 50 Pair MDF Box with Mounting Frame as per given Specification etc. complete as required

6

21978

3663

... More
Supply, Installation, Testing & Commissioning of 25 Pair Riser cable as per given Specification etc. complete as required

150

59700

398

... More
Supply, Installation, Testing & Commissioning of 42U 800mmX800mm Closed Network Rack with standard accessories as per given Specification etc. complete as required

1

82099

82099

... More
Supply, Installation, Testing & Commissioning of 12 Socket PDU as per given Specification etc. complete as required

2

7200

3600

... More
Supply, Installation, Testing & Commissioning of 6 Core Single Mode Fiber ( Armored) Cable as per given Specification etc. complete as required

100

15200

152

... More
Supply, Installation, Testing & Commissioning of 12 Port Fiber LIU Loaded with SC SM Coupler, as per given Specification etc. complete as required

2

37892

18946

... More
Supply, Installation, Testing & Commissioning of 24 Port Fiber LIU Loaded with SC SM Coupler, as per given Specification etc. complete as required

2

71994

35997

... More
Supply, Installation, Testing & Commissioning of 6 Port Fiber LIU Loaded with SC SM Coupler, as per given Specification etc. complete as required

6

75786

12631

... More
Supply, Installation, Testing & Commissioning of SC MM Pigtail (1.0 Mtr) as per given Specification etc. complete as required

6

4170

695

... More
Supply, Installation, Testing & Commissioning of SC-LC SM Fiber Patch Cords ( 3 Mtr) as per given Specification etc. complete as required

36

81864

2274

... More
Supply, Installation, Testing & Commissioning of 6 Core Multi Mode Fiber ( Armored) Cable as per given Specification etc. complete as required

100

53700

537

... More
Supply, Installation, Testing & Commissioning of 12 Port Fiber LIU Loaded with SC MM Coupler, as per given Specification etc. complete as required

6

113676

18946

... More
Supply, Installation, Testing & Commissioning of 24 Port Fiber LIU Loaded with SC MM Coupler, as per given Specification etc. complete as required

1

37892

37892

... More
Supply, Installation, Testing & Commissioning of SC MM Pigtail (1.0 Mtr) as per given Specification etc. complete as required

168

116760

695

... More
Supply, Installation, Testing & Commissioning of Blank Panel for LIU as per given Specification etc. complete as required

5

2530

506

... More
Supply, Installation, Testing & Commissioning of SC-LC MM Fiber Patch Cords ( 3 Mtr) as per given Specification etc. complete as required

6

14400

2400

... More
Supply, Installation, Testing & Commissioning of 2 port faceplate with Gang Box etc. complete as required

1320

183480

139

... More
Supply, Installation, Testing & Commissioning of LSZH Cat 6A-10G speed unshielded twisted pair computer cable with 23 AWG solid copper conductors in existing concealed/surface conduits/Raceways complete 305 Mtr. Roll as per specification etc. complete as required

250

7546750

30187

... More
Supply, Installation, Testing & Commissioning of UTP Cat-6A Information Outlet Red for Data as per specification etc. complete as required

1320

1075800

815

... More
Supply, Installation, Testing & Commissioning of UTP Cat-6A Information Outlet Yellow for Voice as per specification etc. complete as required

262

213530

815

... More
Supply, Installation, Testing & Commissioning of Core Switch as per the given Specification etc. complete as required

1

997807

997807

... More
Supply, Installation, Testing & Commissioning of Layer 3 Distribution Switch as per the given Specification etc. complete as required

2

1503026

751513

... More
Supply, Installation, Testing & Commissioning of Wireless LAN Controller which can control up to 50 APs as per the given Specification etc. complete as required

1

1705114

1705114

... More
Supply, Installation, Testing & Commissioning of Layer 2 Switch 48 Port as per the given Specification etc. complete as required

1

315762

315762

... More
Supply, Installation, Testing & Commissioning of Layer 2 Switch 24port as per the given Specification etc. complete as required

5

868850

173770

... More
Supply, installation, testing & Commissioning of Layer 2 Industrial Switche, 8 Ethernet POE+ Ports, 4 SFP Ports, DIN Rail/Wall Mountable, Highly Resilient LACP, Spanning tree STP, RSTP & MSTP, fast Ring fail-over and G.8032 ERPS protection options, Rugged IP30 Enclosure complete as required.

3

454698

151566

... More
Supply, installation, testing & Commissioning of Layer 2 Industrial Switch, 4 Ethernet POE+ Ports, 2 SFP Ports, DIN Rail/Wall Mountable, Highly Resilient LACP, Spanning tree STP, RSTP & MSTP, fast Ring fail-over and G.8032 ERPS protection options, Rugged IP30 Enclosure complete as required.

3

322077

107359

... More
Supply, installation, testing & Commissioning for Media convertor 1000 Mbps with Industrial grade standard with IP 6 rated with PoE injection with all accessories as required.

2

50000

25000

... More
Supply, Installation, Testing & Commissioning of Access point which can support the given Controller as per the given Specification etc. complete as required

6

390000

65000

... More
Supply , Installtion , Testing and Comissioning of IPPBX in HA mode with 04 Port Voicemail 4 Trunk lines and 1 PRI Trunk lines (64 Ch) Circuit with CLIP Facility, 48 IP users License, 01 Nos. IP Operator Console, 12 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference ,Call Barring, Call Pickup, TEC should be with GR Number.

1

1124112

1124112

... More
Supply, Installation, Testing & Commissioning of High End Digital Key Phone 6x24 Display with 24 Programmable Dual Color LED’s with 4 Feature Access Keys, multi-step Tilt angle adjustment, Navigator Key, backlit display, should have option to connect Blue Tooth etc. complete as required

2

41682

20841

... More
Supply, Installation, Testing & Commissioning of Digital, 2x3 programmable keys, backlit screen, Wideband comfort handset, headset and hands-free, Hearing aid compatible (HAC), Full-duplex hands-freeetc. complete as required

5

64420

12884

... More
Supply, Installation, Testing & Commissioning of IP PHONE with 4.3” touch screen, corded or cordless handset, 2x3 programmable keys, Full-duplex, super-wideband speakerphone complete as required

2

65174

32587

... More
Supply, Installation, Testing & Commissioning of IP Phone 2x Gigabit Ethernet 2x3 programmable keys, 2.8" backlit screen USB a/cetc. complete as required

5

59995

11999

... More
Supply, Installation, Testing & Commissioning of Analog Phone With Speaker , Small Display etc. complete as required

248

469960

1895

... More
CHAPTER-15: IP BASED CCTV SYSTEM

-

-

-

... More
Supply, installation, testing & Commissioning of 2MP IP Indoor Dome Camera ,1/2.8" CMOS, lens2.8-12mm, Auto zoom and focus, H.265, H.264 compression,Smart Codec, internal 850nm Adaptive IR Range min 50 meter , 120dB true WDR as per IEC 62676, Bi directional Full Duplex Audio,inbuilt microphone, 1 Alarm In, 1 Alarm out, Triple streaming fully configurable in H.265,smart compression with CBR & CVBR, Motion Detection, Camera Sabotage, Audio Detection, Object Counting, Adaptive Motion, Object Removal, and Directional Motion,IP64,NEMA 4X,IK10, Camera shall support SD card min 1TB, ONVIF profile S,G, & T,NDAA, UL and cUL Listed - UL 60950-1, CE, FCC,EN, NDAA.

40

1000000

25000

... More
Supply, installation, testing & Commissioning of 2MP IP Outdoor Bullet Camera ,1/2.8" CMOS, lens2.8-12mm, Auto zoom and focus, H.265, H.264 compression,Smart Codec, internal 850nm Adaptive IR Range min 50 meter , 120dB true WDR as per IEC 62676, Bi directional Full Duplex Audio,inbuilt microphone, 1 Alarm In, 1 Alarm out, Triple streaming fully configurable in H.265,smart compression with CBR & CVBR, Motion Detection, Camera Sabotage, Audio Detection, Object Counting, Adaptive Motion, Object Removal, and Directional Motion,IP64,NEMA 4X,IK10, Camera shall support SD card min 1TB, ONVIF profile S,G, & T,NDAA, UL and cUL Listed - UL 60950-1, UL 60950-22,CE, FCC,EN,NDAA.

45

1170000

26000

... More
Supply, installation, testing & Commissioning of Panaromic Camera 12 Megapixel WDR & Day/Night , H.265/H.264/MJPEG , 360° FOV, 1/2.3” CMOS Sensor,3008x3008,1.6mm lens , Surface mount, 12meter IR Range, Line level I/O and built-in microphone, Alam 1 IN & out, 2 x microSDXC slots,IP67, IK10,NEMA 4X,PoE Powered Fan should have UL, CE & FCC Certified etc. all complete as required

4

160000

40000

... More
Supply, installation, testing & Commissioning of Video Management Management servers Rack type server, Intel® Xeon® Silver 4210, 64 GB DDR4 ECC memory,Microsoft Windows server 2019,1 GbE Network ports (2x), 10 GbE SFP+ ports (2x), dedicated iDRAC port.

1

500000

500000

... More
Supply installation Testing and Commissioning of Video Management Recording servers and storage with 100 Channel Liscences.It should have Intel Xeon Intel® Xeon® Silver 4210 or better with 32 GB memory, OS RAID 1. It should run on Windows19 or latest. It should support RAID5/6.It should have dual power Supply. It shall have minimum 12 HDD slots with capacity of minimum 12 TB each . NVR shall have recording Thoughput minimum 700 Mbps at 1Gbe Port. VMS incorporates FIPS 140-3 validated cryptographic modules, it shall support LDAP, TLS-based encryption over HTTPS, shall be of same camera make for seamless integration

1

900000

900000

... More
Supply, installation, testing & Commissioning of Hard Disk Special Surveillance 12TB 3.5" SATA HDD internal( For Servers) etc. all complete as required.

24

936000

39000

... More
Supply, installation, testing & Commissioning of Professional Grade Video Wall Display Panel, 55" Screen Size, Native resolution 1920 x 1080 (16:9), Portrait and landscape, 1.7mm combined bezel to bezel, Brightness 500 nits, Contrast ratio 4000:1 or better etc. all complete as required

6

540000

90000

... More
Supply, installation, testing & Commissioning of Video Wall mpount bracket with push-pull option with accessories etc all complete as required

6

72000

12000

... More
Supply, installation, testing & Commissioning of 9 U Wall Mount Rack power Strip, PDU, 2 nos of Cable manager and Hardware Mounting Kit etc. all complete as required.

3

42000

14000

... More
Supply, installation, testing & Commissioning of 6 U Wall Mount Rack, power Strip, PDU, 2 nos of Cable manager and Hardware Mounting Kit etc. all complete as required.

3

30000

10000

... More
Supply, installation, testing & Commissioning of 6 U Outdoor Pole/Wall Mount Rack, power Strip, PDU, 2 nos of Cable manager and Hardware Mounting Kit etc. all complete as required.

1

18000

18000

... More
Supply, installation, testing & Commissioning of 42 U Floor Mount Rack, power Strip, PDU, Cable manager and Hardware Mounting Kit etc. all complete as required.

1

70000

70000

... More
Supply, installation, testing & Commissioning for UTP Cat-6A Information Outlet with all accessories complete as required.

170

136000

800

... More
Supply, installation, testing & Commissioning of LSZH Cat 6A-10G speed unshielded twisted pair computer cable with 23 AWG solid copper conductors in existing concealed/surface conduits/Raceways complete 305 Mtr. Roll as per specification etc. all complete as required.

26

728000

28000

... More
Supply, installation, testing & Commissioning of Accessories for camera termination. This also includes Camera Distributor/Junction Box/Interfaces.. etc. all complete as required.

12

69600

5800

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20 mm

2000

446000

223

... More
25mm

1200

307200

256

... More
32mm

600

195600

326

... More
CHAPTER 16: RISING MAIN & BUS DUCT

-

-

-

... More
Supplying, installing on wall, testing and commissioning of following capacity Air Insulated Compact Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.

-

-

-

... More
630 A Isc = 50kA for 1 second

36

462816

12856

... More
800 A Isc = 50kA for 1 second

14

262108

18722

... More
Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 800 A 50kA SC for 1 sec

2

35786

17893

... More
Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required

-

-

-

... More
125 A 15kA SC for 1 sec

6

52026

8671

... More
200 A 25kA SC for 1 sec

8

69368

8671

... More
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in the cubical panel, making connections etc. as required. (for VTPN DB+Plug in Box)

-

-

-

... More
125 A, 16kA, TP MCCB

6

28926

4821

... More
200 A, 16kA, TP MCCB

8

61528

7691

... More
800 A, 50kA, TP MCCB

2

72320

36160

... More
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains/ BUS Ducts for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 2000 A 50kA SC for 1 sec

10

401540

40154

... More
Fire FightingCHAPTER 1 : FIRE PUMPS AND ACCESSORIES

-

-

-

... More
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automaticoperation and consisting of following, complete in allrespects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. ( Note: The head of the pump is selected in a manner so as to give a minimum 3.5kgf/sq.cm. pressure at the highest/ farthest point.

-

-

-

... More
2280 LPM 70m Head

1

369064

369064

... More
Supplying, nstallation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard pecification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. Note: * The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.

-

-

-

... More
2280 LPM 70m Head

1

612065

612065

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.

-

-

-

... More
180 LPM 70m Head

1

103304

103304

... More
Supplying, Installation, Testing and commissioning of electric driven terrace pump set on the terrace of the building suitable for automatic operation as per specification as required & comprising of following :- Horizontal mono-block centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ A.C supply. The pump casing shall be CI, shaft shall be CS & impeller / shaft sleeve / casing wearing ring shall be bronze and with Mechanical seal. The system shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side. (The pump should be tested for duty point test at factory and shall be approved by the Local Fire Authority). Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 HZ AC supply for the above pump with speed of 2900 R.P.M. Suitable cement concrete foundation with plaster, (design and drawing to be provided by the Contractor while the foundation will be done by others) complete with Antivibration arrangement of cushy foot mounting. Control Panels, wiring and other accessories shall also be included. For pump defined above & of duty as follows : Flow

-

-

-

... More
900 LPM and Head 35 mtr.

1

101859

101859

... More
Providing & fixing MS Class ‘C’ diesel engine exhaust pipe (including all fittings, clamps, steel support) of 100mm dia for the engine. The pipe shall be insulated with 100 mm thick mineral wool insulation wrapped in chicken mesh and clad with 24 gauge aluminium sheet.

15

75000

5000

... More
Providing, fixing, testing and commissioning of precharged air vessel conforming to IS 2825 (size 450 mm dia & 2000 mm height cylinderical shell thickness not less than 6 mm and dish thickness not less than 8 mm) for pressurization of hydrant / sprinkler system complete with adequate pressure switches (as per design / requirement) with valves to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, 25 mm dia inlet with isolating valve duly painted from inside and outside complete as required.

1

50000

50000

... More
Providing and fixing pressure switch

3

10500

3500

... More
Providing, fixing, testing & commissioning of Air release valve with 15mm dia stop cock, flanged inlet connection, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS IS : 12992 (Part 1).

5

7500

1500

... More
Providing, fixing, testing & commissioning of dial type (100 mm) pressure gauge (glycerin filled) with isolation ball valve suitable for working pressure of 250 PSI with no Syphon. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required. (Range 0-16 kg/cm2)

5

5000

1000

... More
Supply, Installation, Testing and commissioning of slim seal type C.I. Butterfly valve confirming to IS 13592 (Body : Grey Cast Iron, shaft : SS, Disc : SG Iron (Rilson coated), Liner : HT - EPDM) of approved make with PN 16 rating flange dimensions shall be confirming to IS 6392, washer, nuts & bolts. Rated to temperature of 85 Deg C and tested to a pressure not less than 24 Kg/Sq.cm.

-

-

-

... More
(a) 65 mm dia

1

3703

3703.42

... More
(b) 80 mm dia

1

4500

4500

... More
(c) 100 mm dia

2

11000

5500

... More
(d) 150 mm dia

5

40550

8110.06

... More
(e) 200 mm dia

2

38568

19284.25

... More
Providing, fixing, testing and commissioning of dual plate check valve (Body : Grey Cast Iron, Closure plate,bracket, hinge pin, washer, spring, set screw and plate : SS, seat : HT - EPDM) of pressure 16 Kg/sq.cm with flanges ( test pressure of 24 kg / sqcm), Nut,bolts & washers, painting etc. complete as required.

-

-

-

... More
(a) 80 mm dia

2

15000

7500

... More
(b) 150 mm dia

2

23287

11643.99

... More
Supplying, installation, testing and commissioning of Cast Iron Y-Type Strainer (PN 16) with Cast iron Body and Cover, stainless steel (AISI 304) screen with 1-3mm perforation, Rubber gasket and carbon steel Stud and nut. The strainer shall be compatible to be installed between flanges as per BS 10 table F. The cost of the valves to be inclusive of flanges on either ends with rubber gaskets, nuts, washers etc. complete as required as per the satisfaction of the engineer in charge. The body of the Strainer to be tested to a pressure of 24 Kg / sqcm.

-

-

-

... More
200 mm nominal bore

1

22265

22265

... More
Providing & fixing heavy duty double flanged flexicon rubber expansion joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required.

-

-

-

... More
(b) 80 mm dia

1

6000

6000

... More
(d) 150 mm dia

2

15000

7500

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

-

-

-

... More
(a) 25 mm dia

15

11160

744

... More
(b) 32 mm dia

5

4255

851

... More
(c) 40 mm dia

5

5170

1034

... More
(d) 50 mm dia

8

10248

1281

... More
(e) 65 mm dia

10

16140

1614

... More
(f) 80 mm dia

5

9425

1885

... More
(g) 100 mm dia

5

12775

2555

... More
(h) 150 mm dia

35

125090

3574

... More
(i) 200 mm dia

12

65556

5463

... More
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket.

-

-

-

... More
150mm dia

1

48202

48202

... More
Subtotal carried over to summary

-

-

-

... More
CHAPTER 2 : INTERNAL HYDRANT

-

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

-

-

-

... More
(a) 25 mm dia

50

37200

744

... More
(c) 80 mm dia

50

94250

1885

... More
(d) 100 mm dia

75

191625

2555

... More
(e) 150 mm dia

625

2233750

3574

... More
Providing & fixing butterfly valve conforming to IS 13095 PN 16 (Body : Grey Cast Iron, Shaft : SS, Disc : SS, Liner : HT - EPDM) (upto 150mm dia with hand lever operation & above with gear box operation). Including rubber gasket, flanges nuts, bolts, washers & painting complete as required as per specification.(suitable for test pressure of 24 kg / sqcm)

-

-

-

... More
80 mm dia

46

207000

4500

... More
100 mm dia

10

55000

5500

... More
150 mm dia

8

64880

8110.06

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Stainless Steel cap and chain as required :

-

-

-

... More
Single headed Stainless Steel

43

328778

7646

... More
Providing, fixing, testing & commissioning of swinging type First Aid hose reel in red colour drum ( LPCB approved) with 36.5 mts. long and 20 mm dia heavy duty rubber water hose, 20 mm dia Ball valve stop cock, terminating with G.M coupling & nozzle of 6mm outlet with shut off valve confirming to IS 8090 - 1976 complete with MS socket for tap-off, drum and brackets (including painting) for fixing on wall with anchor fastner, bolts & nuts conforming to IS:884-1969 complete as required.

36

382681

10630.05

... More
Supplying, installation, testing and commissioning of rubber reinforced lined fire hose pipe (Conforming to IS : 636-1988) Type-B of 63 mm dia and length of 15 mtr. The hose shall be rated for a brust pressure of 35.7 Kg/sqcm. The hydrostatic proof pressure test for the hose to be in accordance with IS 445-1975. Hose shall be complete with ISI marked brass male & female coupling (IS:903-1993) bound & rivetted to hose pipe with copper rivets & 1.5 mm copper wire etc complete in all respect as per the satisfaction of the engineer in charge. (Location : Internal fire hydrant)

86

664860

7730.94

... More
Supplying & fixing 63 mm dia SS short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :

-

-

-

... More
Stainless Steel

43

103888

2416

... More
Providing, fixing, testing & commissioning of standard firemans axe with heavy rubber handle.

36

43200

1200

... More
Providing, fixing, testing & commissioning of Fire Cabinet fabricated from 40 x 40 x 5 angle iron sections and 14 gauge MS sheet with full front glass door, suitable to accommodate landing valves, 15 m long hoses, first-aid hose reel and branch pipe nozzle, fire extingui & fire mans’ axe. The shutter shall be painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade, as required (Approx 2.1 m (high) x 0.9 m (wide)x 0.6m (deep). (Cost shall be inclusive of providing break glass box containing key for the cabinet along with hamer).

36

655643

18212.32

... More
CHAPTER 3 : SPRINKLER SYSTEM

-

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

-

-

-

... More
(a) 25 mm dia

900

669600

744

... More
(b) 32 mm dia

85

72335

851

... More
(c) 40 mm dia

75

77550

1034

... More
(d) 50 mm dia

150

192150

1281

... More
(e) 65 mm dia

85

137190

1614

... More
(f) 80 mm dia

50

94250

1885

... More
(g) 100 mm dia

40

102200

2555

... More
(h) 150 mm dia

150

536100

3574

... More
Providing, fixing, testing & commissioning of brass quartzoid sprinklers (UL approved) of 15 mm dia size, suitable for sustaining the pressure on the seat & water hammer effect. The type & temperature rating shall be as follows : (a) Pendant Sprinkler (68 deg.C)

430

215000

500

... More
Providing and fixing of corrugated stainless steel (AISI 304) unbraided flexible sprinkler pipe drops of 25 mm dia of following length and maximum working pressure of 175 psi with all accessories and clamps as required. The flexible pipe drop shall be UL approved. The pipe drop shall be of following sizes: 1.2 M length

430

1074441

2498.7

... More
CHAPTER 4 : FIRE EXTINGUISHERS

-

-

-

... More
Providing & fixing ISI marked (IS: 15683 : 2006) portable CO2 type fire extinguisher type 4 kg capacity. Including valve, discharge hose of not less than 10 mm dia & 1 M long complete in all respects including initial filled with CO2 gas confirming to IS:307-1966 & filled to a filling rate of not more than 0.667 and wall suspension bracket.

36

216000

6000

... More
Providing & fixing of ABC Type, Portable Fire Extinguisher, dry powder type (Gas Cartridge) conforming to IS: 15683 : 2006 with cylinder initially fully charged with dry powder, ISI marked confirming to IS:15683 : 2006 complete with standard discharge valve with tube, CI bracket for wall mounting. (a) 4 Kg

36

108000

3000

... More
Providing and fixing Clean agent type potable fire extinguisher with cyclinders initially fully charged ISI marked confirming to IS: 15683: 2006 complete with standard discharge valve with tube, CI bracket for wall mounting. (for computer Lab and Server Room) 4kg

2

30000

15000

... More
CHAPTER 5 : EXTERNAL FIRE HYDRANT SYSTEM.

-

-

-

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :

-

-

-

... More
4 way - 150 mm dia M.S. Pipe

1

13974

13974

... More
Providing and fixing of SS fire brigade suction hose coupling (draw-out connection) with nut for female coupling complete with 100 mm dia GI suction pipe and 100 mm dia foot valve (to be connected to static tank). Provision of GI drop pipe and foot valve shall be made in all the fire water static storage tanks (4 No) (GI pipe to be paid separately through appropriate item while cost of foot valve to be included).

1

11893

11893.76

... More
CHAPTER 6 : GAS SUPPRESSION SYSTEM

-

-

-

... More
Novec at 50/42 BAR , complete with valve assembly and arrangement for supervisory switch connection for monitoring cylinder pressure , a pressure gauge (Main) -1no. Supply, installation ,testing and commissioning of NOVEC 1230 AGENT PER 1KG. -1no. Supply , installation , testing and commissioning of Electric control head operated electrically from the Detection & control system or locally with a manually level on the control head . Supply , installation , testing and commissioning of pressure operated Control Head. Supply , installation , testing & commissioning of Master Cylinder Adapter kit used to actuate the Slave cylinder -1no. Supply , installation , testing & commissioning of Flexible discharge Hose route the Novec Agent from the storage cylinders to the discharge piping by a 2" flexible rubber hose with wire braided reinforcements. This hose is connected to the discharge out -1no. Supply, installation , testing & commissioning of Manifold Check Valve installed at the dsicharge manifold to allow removal of any Novec cylinder from the manifold while still remaining a closed system Supply , installation , testing and commissioning of MS Container Strap Supply, installation , testing & commissioning of Flexible Actuation Hose (Pilot pressure is directed to a pressure operated control head on each cylinder valve using 1/4 inch actuation hose) -1no.

-

-

-

... More
Supply, installation , testing & commissioning of Switch, Pressure, DPST, Weather Proof (2 - 3/4 in. Outlets), Latching -1no. Supply, installation , testing & commissioning of Warning Plate for Use Inside Room -1no. Supply, installation , testing & commissioning of Warning Plate for Use Outside Room Supply, installation , testing & commissioning of Manifold fabricated from seamless pipes Sch 80 for 2 Cylinder -1no. Supply , installation , testing & commissioning of Piping with ASTM Sch 40 -1no. Supply , installation , testing & commissioning of Novec gas discharge nozzle -2no. NOZZLE 42/50 BR Supply, installation, testing & commissioning of Photo thermal multicriteria intelligent addressable detector with standard base etc.complete as required and as per specifications.-2no. Supply ,installation, testing & Commissioning of Gas release module (UL listed) of the same make as Fire Detection system complete as required. -1no. Supply ,installation, testing & Commissioning complete set fo gas supression -1no.

1

1041100

1041100

... More
Supply, fixing, testing and commissioning of automatic Linear pneumatic Tube Detection based 3M Novec 1230 System for Electrical Panels (Linear Pnuematic Heat Detection Tube Panel Protection System) with DOT Approved cylinder fitted with automatic valve, Pressure gauge, slip-on push in tube connector,pressure switch, consisting of the Mentioned components , Complete System shall be LPCB Approved Approved Makes- Kidde/Regulus/ Fire Trace/ Minimax MX

-

-

-

... More
4 Kg capacity Novec 1230 , DLP Assembly with automatic valve, push in connector for tube, 4Kg Novec 1230 gas , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.

6

660000

110000

... More
2 Kg capacity Novec 1230 , DLP Assembly with automatic valve, push in connector for tube, 2Kg Novec 1230 gas , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.

10

940000

94000

... More
Linear pneumatic heat Detection Tube with all necessary fittings & supports.

600

1111200

1852

... More
CHAPTER 7 : ELECTRICAL WORKS

-

-

-

... More
CONTROL PANEL

-

-

-

... More
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :

1

287855

287855

... More
Incomings

-

-

-

... More
400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500A

-

-

-

... More
Outgoings

-

-

-

... More
( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)

-

-

-

... More
Main Fire Pump

-

-

-

... More
200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.

-

-

-

... More
Jockey Pump

-

-

-

... More
100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.

-

-

-

... More
Diesel Engine Control

-

-

-

... More
Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications.

-

-

-

... More
Supplying and laying of following 1.1kV grade, XLPE insulated and laying, FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required.

-

-

-

... More
3C X 95 Sqmm

30

25800

860

... More
4C X 10 Sqmm Alluminium Armoured Cable

50

13500

270

... More
Supplying following 1.1kV grade, XLPE insulated , FRLS type control cables,suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required.

-

-

-

... More
2C X 1.5 sqmm copper conductor

30

3750

125

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.

-

-

-

... More
3C X 95 sq. mm (45 mm)

4

2168

542

... More
4C X 10 Sqmm

4

960

240

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
150 mm width x 50 mm depth x 1.6 mm thickness

20

14320

716

... More
300 mm width x 50 mm depth x 1.6 mm thickness

15

14445

963

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable trays "bends" with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

2

2540

1270

... More
300 mm width X 50 mm depth X 1.6 mm thickness

2

3704

1852

... More
FIRE ALARM

-

-

-

... More
Irrespective of whether or not mentioned in the BoQ, all necessary interfaces - such as hardware including any fiber optics modules, if required and/or software - for interconnecting all fire alarm panels at site shall be provided in the system(s). All the fire panels at site shall be operated and monitored in networked mode and shall be integrated with IBMS system over BacNet/IP protocol; all necessary hardware and software applications and licences for the same shall be provided by the vendor.

-

-

-

... More
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.

-

-

-

... More
Ten Loop Panel

2

911068

455534

... More
Note: The Vendor can offer different configuration of loops but the total nos. of Loops will remain same (18 loops) as mentioned in BOQ and accordingly change the qty of no. of panels.

-

-

-

... More
Supply, installation, testing & commissioning of Repeater panel with minimum320 character / touch screen LCD display with inbuilt reset acknowledge and silence switch complete as required.

1

108688

108688

... More
Supplying, installation, testing & commissioning of intelligent analog addressable Photothermal detector complete with mounting base as required.

1694

4841452

2858

... More
Supplying, installation, testing & commissioning of Fault isolator complete with base as required.

200

654000

3270

... More
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.

25

68150

2726

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required.

69

207207

3003

... More
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required.

72

562608

7814

... More
Supplying, installation, testing & commissioning of addressable manual call point complete as required.

50

193550

3871

... More
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.

50

175300

3506

... More
2-core, 1.5 sqmm armoured FRLS CABLE (MR)

15000

1875000

125

... More
Supply, installation,testing and commissioning of EXIT light, self contained 6W luminaire complete with flush mounting frame ,sign label,fluorescent tube and battery and with label EXIT/RIGHT/LEFT/UP/DOWN as required.

72

360000

5000

... More
AMC for five years (after completion DLP)

-

-

-

... More
1st Year

1

724748

724748

... More
2nd Year

1

768833

768833

... More
3rd Year

1

825563

825563

... More
4th Year

1

875097

875097

... More
5th Year

1

925602

925602

... More
SITC OF HVAC SYSTEM

-

-

-

... More
Supply  Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. Compressor same OEM manufaturer,The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit  shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 4.0 and IEER not less than 6.5

-

-

-

... More
Supply of QWIK FOOT supports system consisting of a G I Steel frame modular/multiples along with adjustable legs and UV Stabilised Nylon Rubber Crump- SBR recycled with feet assemblies 205/305 standrd Base. . The frame dimensions should be designed to take the weight with minimal deflection, manufactured from hot dip GI Carbon Steel. Rubber Crump in the base shall be resin bonded Polyurethane Polymer. Welding standard to be as per BS EN ISO 1461-2009 for Hot Dipped GI Assembly. The feet shall be 200/305/mm square made from Nylon 6 B601L 30% glass fibre filled Underneath Rubber for vibrations absorption.The leg assembly should be adjustable between 210 to max.350 mm for max loading per foot assemble to 500kg per foot frame & accommodate unevenness of the terrace floor levels.

-

-

-

... More
Make: Mitsubishi Ele. / Ogeneral / LG / Mitsubishi Heavy

-

-

-

... More
Outdoor Stand Make: Qwik Foot / Hira Walraven

-

-

-

... More
60 HP OUTDOOR UNIT

2

1055450

527725

... More
40 HP OUTDOOR UNIT

8

4221800

527725

... More
18 HP OUTDOOR UNIT

3

1512444

504148

... More
14HP OUT DOOR UNIT

2

781430

390715

... More
12 HP OUT DOOR UNIT

1

370102

370102

... More
8 HP OUT DOOR UNIT

1

336962

336962

... More
INDOOR UNIT-DUCTABLE TYPE

-

-

-

... More
Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.

-

-

-

... More
BASEMENT:-

-

-

-

... More
Ductable unit : 8.0 TR

4

551876

137969

... More
GROUND FLOOR:-

-

-

-

... More
Ductable unit : 8.0 TR

8

1103752

137969

... More
Ductable unit : 4.0 TR

3

221148

73716

... More
FIRST FLOOR :-

-

-

-

... More
Ductable unit : 8.0 TR

4

551876

137969

... More
Ductable unit : 6.5 TR

2

264326

132163

... More
Ductable unit : 4.0 TR

6

442296

73716

... More
Ductable unit : 3.0 TR

2

143026

71513

... More
Ductable unit : 2.0 TR

4

185176

46294

... More
SECOND FLOOR :-

-

-

-

... More
Ductable unit : 8.0 TR

6

827814

137969

... More
Ductable unit : 6.5 TR

1

132163

132163

... More
Ductable unit : 5.5 TR

2

264326

132163

... More
Ductable unit : 4.0 TR

2

147432

73716

... More
Ductable unit : 1.5 TR

4

182400

45600

... More
THIRD FLOOR :-

-

-

-

... More
Ductable unit : 8.0 TR

4

551876

137969

... More
Ductable unit : 6.5 TR

2

264326

132163

... More
Ductable unit : 5.5 TR

12

1585956

132163

... More
INDOOR UNIT-CASSETTE TYPE

-

-

-

... More
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.

-

-

-

... More
BASEMENT:-

-

-

-

... More
Cassette unit : 2.0 TR (950x950)

2

106008

53004

... More
Cassette unit : 1.0 TR (950x950)

2

103210

51605

... More
GROUND FLOOR :-

-

-

-

... More
Cassette unit : 2.5 TR (950x950)

2

108784

54392

... More
Cassette unit : 1.5 TR (950x950)

3

157260

52420

... More
INDOOR UNIT-HI-WALL TYPE

-

-

-

... More
Supply, installation, testing and commissioning of following minimum capacity VRV/VRF Highwall type Indoor unit equipped with washable synthetic mediapre-filter, fan section with low noise fan / dynamically balanced blower , multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drainpan, necessary accessories etc., suitable for operation on 230V±10%, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.

-

-

-

... More
BASEMENT:-

-

-

-

... More
HI-Wall unit : 2.0 TR

3

114657

38219

... More
GROUND FLOOR :-

-

-

-

... More
HI-Wall unit : 2.0 TR

6

229314

38219

... More
FIRST FLOOR :-

-

-

-

... More
HI-Wall unit : 2.0 TR

6

229314

38219

... More
SECOND FLOOR :-

-

-

-

... More
HI-Wall unit : 2.0 TR

6

229314

38219

... More
THIRD FLOOR :-

-

-

-

... More
HI-Wall unit : 2.0 TR

6

229314

38219

... More
FOURTH FLOOR :-

-

-

-

... More
Y-JOINTS

-

-

-

... More
Supply,Installation,Testing and Commissioning of Y-joints for various pipe sizes and headers etc.

50

413150

8263

... More
COPPER REFRIGERANT PIPING

-

-

-

... More
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :

-

-

-

... More
Make: Rajco / Hindustan / Mandev

-

-

-

... More
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

200

70000

350

... More
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

350

150850

431

... More
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

600

342000

570

... More
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

575

399625

695

... More
19.0 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

450

382500

850

... More
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

500

505000

1010

... More
25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

300

360000

1200

... More
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

200

261600

1308

... More
31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

250

347500

1390

... More
34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

300

435000

1450

... More
38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

400

600000

1500

... More
41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

350

551250

1575

... More
CABLE TRAY FOR REFRIGERANT PIPING

-

-

-

... More
Supplying and installing following size of perforated hot dip galvanized G.I cable tray with perforations not more than 17.5%, in convenient sections, joined with connectors, suspended from ceiling with G.I suspenders including bolts and nuts, etc. for carrying refrigerant pipe in outdoor application as required.

-

-

-

... More
Make: SKS / Adity Steel

-

-

-

... More
450 mm width x 100 mm depth x 1.6 mm thickness

200

236800

1184

... More
300 mm width x 100 mm depth x 1.6 mm thickness

275

241450

878

... More
150 mm width x 100 mm depth x 1.6 mm thickness

580

327700

565

... More
AIR PURIFICATION SYSTEM (Plasma / Bipolar Ionizations)

-

-

-

... More
CONDENSATE DRAIN

-

-

-

... More
Supply & Installation of heavy duty PVC/UPVC drain pipe with min. wall thickness of 4 mm with insulation including cutting and chasing in wall for crossing and making good the same if required.Insulation shall be of 6 mm thick sleeve of nitrile rubber/polyethylene foam having. Insulation on drain pipe shall be carried out only where the pipe is running within the wall. Exposed pipe shall be with insulation. The insulation joints shall be properly sealed with rubber based adhesive to ensure proper bonding.

-

-

-

... More
25 mm with 6mm thick insulation

200

36600

183

... More
32 mm with 6mm thick insulation

150

32400

216

... More
40 mm with 6mm thick insulation

200

51000

255

... More
Subtotal carried over to summary

-

-

-

... More
PROPELLER FAN

-

-

-

... More
Supply, installation, testing and commissioning of propeller fan with Al./SS blades and complete with induction Motor suitable for operation with 230 V single phase 50 Hz with suitable frame etc. as per IS:2312-1967 with gravity dampers for exhaust complete as per specifications and drawings.The quoted price shall consist of mounting arrangemnt for the fan. The maximum sound level of unit shall be 40dB(A) @ 3 m from source.

-

-

-

... More
200 DIA

12

71988

5999

... More
Subtotal carried over to summary

-

-

-

... More
SH:3: AIR DISTRIBUTION

-

-

-

... More
GSS DUCT (FACTORY FABRICATED)

-

-

-

... More
Supply, fabrication, installation, testing and commissioning of GSS sheet metal ducting for supply & return air with all the accessories and hanging arrangement. It shall include bends,elbow,tees,spliter,fittings,gaskets and all accessories for complete installation of ducting, Refer tender specification for detail description.Note: all hanging support GRIPPLE / HIRA WALRAVEN guide line (SMACNA)

-

-

-

... More
24 G (0.63 mm)

2000

2160000

1080

... More
22 G (0.80 mm)

1200

1515600

1263

... More
20 G (1.00 mm)

200

276200

1381

... More
18 G (1.25 mm)

100

183600

1836

... More
GSS DUCT (SITE FABRICATED)

-

-

-

... More
Supply, fabrication, installation, testing and commissioning of G.S.S. sheet metal ducting for supply & return air with all the accessories and hanging arrangement.It shall include bends,elbow,tees,spliter,fittings,gaskets and all accessories for complete installation of ducting.Refer tender specification for detail description. Note: all hanging support GRIPPLE / HIRA WALRAVEN guide line (SMACNA)

-

-

-

... More
24 G (0.63 mm)

300

317400

1058

... More
22 G (0.80 mm)

150

184350

1229

... More
20 G (1.0 mm)

100

162900

1629

... More
VOLUME CONTROL DAMPER

-

-

-

... More
Supplying, installing, testing & commissioning of GI volume control damper with minimum 1.6 mm flange and 1.8 mm blade thickness within ducts to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system as per schedules & drawings.

30

211380

7046

... More
SUPPLY AIR GRILL

-

-

-

... More
Supply, installation, testing,balancing and fixing of Powder coated aluminium extruded grill with aluminium construction collar damper for supply air as per specification & the sizes will be as per schedules and drawing.Refer technical specification for detail description

25

227625

9105

... More
RETURN AIR GRILL

-

-

-

... More
Supply, installation, testing ,balancing and fixing of Powder coated aluminium extruded grill for return air as per specification & the sizes will be as per schedules and drawing.Refer technical specification for detail description

25

147750

5910

... More
SUPPLY AIR DIFFUSER

-

-

-

... More
Supply, installation, testing,balancing and fixing of Powder coated aluminium extruded Diffuser with collar damper for supply air as per specification & the sizes will be as per schedules and drawing.Refer technical specification for detail description

120

1462080

12184

... More
RETURN AIR DIFFUSER

-

-

-

... More
Supply, installation, testing ,balancing and fixing of Powder coated aluminium extruded Diffuser for return air as per specification & the sizes will be as per schedules and drawing.Refer technical specification for detail description

120

974520

8121

... More
FLEXIBLE DUCT

-

-

-

... More
Supply, installation, testing and commissioning of aluminium insulated flexible duct to connect the diffuser .It shall be as per specification & the sizes will be as per drawings and schedules :

-

-

-

... More
200 mm Dia

550

321750

585

... More
All Air distribution Low Side Make: Trox / Pineair / Ruskin Titus/ P.tech

-

-

-

... More
SH:4: INSULATION Duct Thermal Insulation (Internal Duct) Supplying, laying,fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class ‘O’ applied by suiatable adhesive, as per specifications and as required complete in all respect. Make: Hira / Supereme / Armaflex

-

-

-

... More
19 mm on Supply duct

240

180960

754

... More
25 mm on Return duct

350

338800

968

... More
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specificationskg/cu.m with in built Microban and tested as per ISO 354:2003 complete as required and as per specifications.

-

-

-

... More
25 mm thick

3000

2124000

708

... More
LAG COATING FOR DUCT & COPPER REFRIGERANT PIPING Supplying, applying, testing and commissioning of Duct and copeer piping Thermal Insulation for copeer piping, supply/return air ducts of closed cell elastomeric nitrile rubber foam insulation(as per the table shown in dwg) using Rubber based adhesive like AC Ductking/SR505 on poly-chloroprene basis, free of aromatic solvent. Thermal conductivity max. 0,037 W/(m*K) @ +20 Deg C shall be considered for selection of insulation material. Density 40-55 Kg/ Cum complete as per specifications. (For Inernal Application)The insulation over ducts/Pipes shall be finished with two coats of 500 micron (0.5 mm) WFT Fire Retardant coating conforming to UL 723 Class A and ASTM 4804, sandwiched with 7 Mil Class E Glass Cloth. (For External Application) hall be finished with two coats of 500 micron (0.5 mm) WFT Fire Retardant weathering resistant coating conforming to ASTM 6695 and having excellent rainwater resistant, high level water primality resistant and must be Anti- Fungal and Anti-Mold (both properties) conforming to relevant internationally acclaimed std. such as ASTM D 6904, ASTM D 2842, ASTM D 5590 and ASTM D 5589 the coating has to confirmed to ASTM E 96 for water vapor permeability and coating fire resistance properties such ASTM 4804 and ASTM E 84 sandwiched with 10 Mil Class E Glass Cloth Make: Pedilite / Armaflex

1000

392000

392

... More
UNDERDECK THERMAL INSULATION Supply and fixing of UL approved Underdeck thermal insulation for the roofs with 25 mm thick closed cell nitrile rubber insulation of class 'O' Fire rating confirming to BS 476 part 6 including providing adhesive, adhesive tapes, etc all complete

3400

2240600

659

... More
DOUBLE LAYER CANVAS CONNECTION Supply,Installation,testing and commissioning of double Layer canvas connection fire retardant cloth for the end connection of AHU/CSU/AIR WASHER/SCRUBBER/TFA and Ventilation fan to reduce the vibration.It shall be fire rated for atleat 2 hrs.Refer tender specification for detail description

100

680300

6803



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.