Shri Mata Vaishno Devi University Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Shri Mata Vaishno Devi University - SMVDU Tender
Civil And Construction
Building Construction
Eprocure
Opening Date29 Jun 2024
Closing Date12 Jul 2024
Tender Amount₹ 24,50,716
Costs
EMD
₹ 49,020Document Cost
₹ 600Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_SM_251497_1Bid Award Id
ViewTender No
SMVDU/Engg/Tenders/24/21 dated 28-06-2024Tender Authority
Shri Mata Vaishno Devi University ViewPurchaser Address
-Website
http://https://www.smvdu.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Addition Alteration of Basohli Boys Hostel C and D block Balance work in SMVDU Kakryal Katra
BOQ Items
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item
-
-
-
With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)
16.51
19648
1190.1
Extra for using stainless steel grade 304 wire gauge with wire of dia. 0.5 mm instead of Galvanized M.S. Wire gauge with wire of dia. 0.63 mm for doors, windows and clerestory windows with necessary screws: (shutter area to be measured
16.51
2350
142.35
355x19mm
40
12038
300.95
Powder coated minimum thickness 50 micron aluminum
40
3024
75.6
With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws
48.37
156438
3234.2
75x50x2.50 mm
75
5223
69.65
250x10 mm
50
5437
108.75
100x10 mm
50
3177
63.55
125 mm
50
3400
68
75 mm
50
3000
60
Twin rubber stopper
25
1586
63.45
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. One coat on old surface of ceiling
602.31
52220
86.7
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete
-
-
-
250x16 mm
25
6298
251.95
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface
982.69
64022
65.15
Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work
982.69
131533
133.85
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
Group 'A'
100
101500
1015
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
-
-
-
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
250
58250
233
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
500
137500
275
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
80
60320
754
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
-
-
-
25 mm
300
43500
145
Supplying and fixing of following sizes switch /socket on the existing modular plate and switch box including connections but exluding modular plate as required
-
-
-
5/6Amp Switch
25
2575
103
3 Pin 5/6 Amp Socket Outlet
25
3050
122
15/16Amp Switch
60
9360
156
6 Pin 15/16 Amp Socket Outlet
60
11820
197
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
60
22140
369
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
50
2000
40
Supplying and fixing following Modular base & cover plate on
existing modular metal boxes etc. as required
-
-
-
12 Module
25
6800
272
3 Module
60
9060
151
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
Group B
15
11295
753
Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single Pole
120
30720
256
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
40 Amp TPN
6
5820
970
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
8 way (4 + 24), Double Door
6
35802
5967
Supplying and installing following size of perforated painted
with powder coating M.S. cable trays with perforation not more
than 17.5%, in convenient sections, joined with connectors,
suspended from the ceiling with M.S. suspenders including bolts
& nuts, painting suspenders etc as required
-
-
-
450 mm width X 50 mm depth X 2.0 mm thickness
300
341100
1137
Removal of Existing LED tube light fixture & Fixing in the new location as required , including connection , testing and commissioning.
130
26000
200
Removal of Existing ceiling fan & Fixing in the new location by way of Anchor fasterering in the ceiling as required including connection , testing and commissioning.
60
15000
250
Supply and Fixing of ceiling fan (Aluminium Body) operating on max 60W, including wiring, the down rods of standard length (upto 30 cm) with 3x1.5 sqmm FRLS PVC insulated copper conductor single core cables,Phenolic sheet cover etc., as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge.
-
-
-
1200 mm sweep ceiling fan upto maximum 60w
15
36000
2400
Supplying,Installation, testing and commissioning of pre-wired, 20W LED ,5700K CCT and aluminium body tubelight fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
25
15000
600
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
-
-
-
2 run of cable
1480
142080
96
3 run of cable
870
116580
134
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
25 mm
600
87000
145
Supply, installation, testing and commissioning of Cat6 Information Outlet (Keystone Jack & Faceplate).
58
20300
350
Network Switch 24P, Managed, Non-PoE
4
70000
17500
Evaluation Notes How It Works ?