Islamic University Of Science And Technology Tender

... More
The IUST has issued a formal invitation for competitive bids for the Islamic University Of Science And Technology project, for Internal Electrification Of Scholar Quarter Block At Iust Campus-i, Awantipora. in Pulwama, Jammu & Kashmir, with an estimated contract value of Rs. 51,85,000. The bid opening date for this tender is 10-02-2025 and the last date for bid submission is 03-03-2025. Interested bidders for Islamic University Of Science And Technology tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Islamic University Of Science And Technology - IUST Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Feb 2025
Closing Date3 Mar 2025
Tender Amount₹ 51,85,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
1 No of Motor Control Panel with MPCB suitable for 2 H.P Motor and DOL Starter with complete protection, including connections, etc as required complete in all respetcs.

-

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)

77

197

15169

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.

53

827

43831

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

222

275

61050

... More
Double pole

18

656

11808

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

434

160

69440

... More
SUB-HEAD-I: POINT WIRING

-

-

-

... More
2 X 1.5 sq. mm

1331

112

149072

... More
The Bus bars will be Copper purity 99.9% / electrolytic grade E91 Aluminium duly sleeved with Helogen Free heat shrink coloured Insulated tube confirming to IEC 6068-3-247 Standard. Provide electrical insulating shrouds, reusable type covers for busbars Boots on corners Panels will be powder coating (60-80micron as per IS:13871 for indoor and 90-100 micron for outdoor), include one size higher terminal block in cable alley and interconnecting wires between bus bars and terminals via MCB. All Bus-Bar alley and relay compartments shall be provide fully automtic control thermotate with strip heater.

-

-

-

... More
2X 16 sq. mm + 1 X 6 sq. mm earth wire

462

789

364518

... More
SUB-HEAD-III: LIGHTNING CONDUCTOR

-

-

-

... More
SUB-HEAD-VII: INSTALLATIONS OF LIGHT FIXTURES AND FANS

-

-

-

... More
6 pin 15/16 amp socket outlet

10

197

1970

... More
TV antenna socket outlet

16

148

2368

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.

-

-

-

... More
2X 16 sq. mm + 1 X 6 sq. mm earth wire

20

1005

20100

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

50

368

18400

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

20

477

9540

... More
1 or 2 Module (75mmX75mm)

18

298

5364

... More
Supply, fixing, testing and commissioning of Lightning counter indicating date and time of last record In-addition having to see previous history of surges etc complete as required to meet requirements to IS/IEC 62561-1 etc. complete as required

1

13456

13456

... More
Supply of indoor type surface/recess mounted downlighter white CRCA powder coated LED light fixture with total system wattage 12W covered by PMMA acrylic diffuser, die cast aluminium housing, high efficiency reflector, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply as required. LED fixture should have minimum efficacy =100 lm/W and minimum system lumens 1200.

317

1080

342360

... More
4 X 185 sq. mm (57mm)

5

670

3350

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in Rooms).

105

676

70980

... More
300 mm width X 50 mm depth X 1.6 mm thickness

20

1254

25080

... More
Providing & installation of 1Set of KWH Multifunction Meter with phase indications on each incommer and all outgoins, complete in all respects.

-

-

-

... More
Supply of Outdoor type 50W, IP66 LED light Dust and Water proof high efficiency reflecctor, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply.

5

4200

21000

... More
Telephone socket outlet

8

148

1184

... More
Supplying and fixing 63A rating, DP 240 V, 10 kA, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc. as required.

18

829

14922

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
2 Sets of 320 Amps 4P, 50kA, 500volts grade busbar chamber of suitable length with Copper busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and, current density of bus-bars shall not be less than 0.8Amps/sq.mm for Aluminium and 1.6Amps/sq.mm for copper cross sectional area of Bus Bar.

-

-

-

... More
Supplying and fixing 63A rating, TPN 415 V, 10 kA, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc. as required.

1

1512

1512

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required

-

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run)

121

108

13068

... More
1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O.

-

-

-

... More
6 Module

105

182

19110

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

4

121

484

... More
Supply of Motion Sensor based surface/recess mounted downlighter white CRCA powder coated LED light fixture with total system wattage 15W covered by PMMA acrylic diffuser, die cast aluminium housing, high efficiency reflector, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply as required. LED fixture should have minimum efficacy =100 lm/W and minimum system lumens 1200.

72

2100

151200

... More
4 Nos. Minimum diamension of 400MM (H) x 300MM(W) or as required size for accomidating the 4No's of Smart Energy Meters, Glass window compartment each with Lock & sealing arrangement including ACP sheet for mounting existing single Phase Smart/Pre-paid Energy Meter by SEB (PDD) and 2 x 16.0sqmm FR PVC copper power wiring colour coded between Meter and busbar. Name plate should also be provided as per flat numbing provided client.

-

-

-

... More
SUB-HEAD-V: CABLE TRAY

-

-

-

... More
Supply of 4 x 185 sq.mm. Power Cables multi stranded Aluminium conductor, XLPE Insulated, cores laid up PVC tape / Extruded Inner sheath , Armour, FRLS at outer sheath,1100V grade as per IS 7098(Part 1) 1988 with upto date amendments.

80

2004

160320

... More
Providng & Installation of 1Set of Colour coded PVC insulated Aluminium Busbar with current carrying capcity for bearing the 300KVA load keeping in consideration of short circuit current also.

-

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

25

1551

38775

20

92

1840

... More
INDICATIONS: 1Set of R,Y,B phase indication lamps with 4Nos. SP HRC fuses as per fault requirement for each Meter.

-

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.

2

17538

35076

... More
4 Module (125mmX75mm)

5

343

1715

... More
Supply of indoor type 10W surface/wall mounted LED Liner decorative fitting (Mirror Light) covered by diffuser, high efficiency reflecctor, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply as required. LED shall be SMD type.

35

1200

42000

... More
8 Module (125mmX125mm)

5

454

2270

... More
METERING & INDICATION

-

-

-

... More
Provide 3Nos indicating lamps for status indication "ON","OFF" , Tripped due to earth fault on each incomer and outgoing MCCB

-

-

-

... More
1 or 2 Module

71

133

9443

... More
Supply of 200-250mm dia sweep PVC body, 1200±10% RPM Exhaust fan with guard and mounting arrangement.

50

1490

74500

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

50

339

16950

... More
12 Module

3

272

816

... More
1 No. of 63A 4P MCCB built in thermal magnetic based release (adjustable O/L, adjustable S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended.

-

-

-

... More
Providing & installation of 01 No. of 40A FP, ATFM release 36KA breaking capacity, 100%Icu MCCB with spreader link, includinng connections, etc as required, complete in all respetcs.

-

-

-

... More
Earth leakage protection relay with 30mA to 300mA with ZCT for each outgoing MCCB.

-

-

-

... More
2 X 6 sq. mm +1 X 6 sq. mm earth wire

40

439

17560

... More
SUB-HEAD-IX: L.T. POWER CABLE

-

-

-

... More
Supply, fixing, testing and commissioning of single spike air terminals of 10 mm dia.of 1Meter long as required and as per site conditions. the air terminal shall be manufactured with aluminium. The terminal shall be provided with the integrated / attached threaded base support suitable for mounting the terminals as per site condition. The base support shall be minimum 3 mm thick and shall have inbuilt connector fitting for connection of lightning conductor in such a way that conductor contact area shall not be less than 40mm on all side of the conductor as per IS/IEC 62305.

3

4569

13707

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No's of 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, 8 Module F,C Plate, connections etc. as required.

18

1120

20160

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in exisitng surface/ recessed medium class PVC conduit , inclusding clearing the existing conduits (if any blockage) etc as required.

-

-

-

... More
Providing & installation of 01 No. of 125A FP, ATFM release 36KA breaking capacity, 100%Icu MCCB with spreader link, includinng connections, etc as required, complete in all respetcs.

-

-

-

... More
Bell push (2Module)

16

140

2240

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

125

586

73250

... More
3 Module (100mmX75mm)

5

327

1635

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
Supplying, installation, testing and commissioning of following bolted fabricated in compartmentalized conform to IS: 8623/1993, Suitable for 415V, 3Phase, 4 Wire 50 Hz Ac supply, are housed in design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plate, bottom base channel of MS section not less than 100mmx 50mmx50mmx 5mm thick for Main L.T. Panel and capacitor panels and 40mmx25mmx25mmx 5mm thickplates for MDB/MCC and SDBs etc., The degree of protection of minimum IP:42 for indoor and IP:65 for outdoor use.

-

-

-

... More
E-Series R,Y,B phase indication lamps with 4Nos. SP HRC fuses as per fault requirement for each Incomer.

-

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

53

369

19557

... More
Above 95 sq. mm and upto 185 sq. mm

50

77

3850

600

110

66000

... More
SUB-HEAD-VI:SUPPLY OF LIGHT FIXTURES AND FANS

-

-

-

... More
6 Module (200mmX75mm)

5

402

2010

... More
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc. as required.

35

178

6230

... More
SUB-HEAD-VIII: LT POWER PANELS AND ENERGY METER PANELS

-

-

-

... More
3 pin 5/6 amp socket outlet

20

122

2440

... More
Single pole

215

256

55040

... More
OUTGOINGS

-

-

-

... More
Group A

525

865

454125

... More
Providing, Installation, testing & commissioning of 3 phase Smart Energy Meter 139-160 Amp, DLMS Compliant of accuracy class 1.0, including connection, etc as required complete in all respects.

1

24995

24995

... More
8 Module

18

211

3798

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.

-

-

-

... More
Providing & installation of 02 No. of 250A FP, ATFM release 36KA breaking capacity, 100%Icu MCCB with spreader link, includinng connections, etc as required, complete in all respetcs.

-

-

-

... More
EP-1 For below SCHOLARS RESIDENTIAL QUARTER (INDOOR PANEL-IP:42)

1

572410

572410

... More
1 No. of 40A 4P MCCB built in thermal magnetic based release (adjustable O/L, adjustable S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended.

-

-

-

... More
OUTGOINGS

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

217

233

50561

... More
i/c cleaning & finishing complete, having extensible type aluminium bus bars of high conductivity, SMC bus bar supports, with short circuit withstand capacity of 31MVA for 1 Sec., fabrication shall be done in transportable sections and all front and back doors shall be hinged type and earth with frame, Entire panel shall have a common aluminium earth bar of size 32mm x 6mm or as specified below at the rear with 2 Nos. earth stud each side, solid inter connections from main bus bar to switch gears upto cable alley, bus bars and control wiring with suitable size of ZHLS PVC insulated copper conductor cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-

-

-

-

... More
Provide 3 Nos. Resin cast CTs, Class-1.0 and MFM True RMS type digital with min. features of measurements covering A,V,Hz, PF, kW,VAr,VA, kVA, kVAR, kWH, kVAH, kVARH,MDI, Harmonics,Run Hours, RS-485 Port, LCD display with class-0.5 accuracy for all incomer feeder. Refer to Cat no. - Enersol PQMR82

-

-

-

... More
2 X 6 sq. mm +1 X 6 sq. mm earth wire

30

310

9300

... More
3 Module

125

151

18875

... More
4 Module

53

158

8374

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

32

1562

49984

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
Group A

10

858

8580

... More
15/16 amp switch

10

156

1560

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed medium class PVC conduit, with modular switch, modular plate and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
1 Nos. 320A 4P MCCB built in Microprocessor based release (adjustable O/L, short circuit,Ground Fault and fixed instantaneous neutral protection) of fault breaking capacity 50KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. (INCOMMER)

-

-

-

... More
1 No of Street lighting Control Panel of capacity 6-10kw with Astronomical time switch, 32A DP Contactor, 40A DP MCB with inbuilt short circuit protection and surge protection with FRLS wiring including connections, etc as required complete in all respetcs.

-

-

-

... More
Supplying, installation, testing and commissioning of following bolted fabricated in compartmentalized conform to IS: 8623/1993, Suitable for 415V, 3Phase, 4 Wire 50 Hz Ac supply, are housed in design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plate, bottom base channel of MS section not less than 100mmx 50mmx50mmx 5mm thick for Outdoor L.T. Power Panel and 40mmx25mmx25mmx 5mm thickplates for MDB/MCC and SDBs etc., The degree of protection of minimum IP:42 for indoor and IP:65 for outdoor use. The Panel must have fully water and weather proof and shall fix it in the concrete at minimum depth of 600mm.

1

250000

250000

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable including surface/ recessed medium class PVC conduit with wall chasing in case of recessed conduits including filling the same with plaster and finished wall putty, etc as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

1331

143

190333

... More
8 way, Double door with Glass Door

1

2072

2072

... More
17 Nos of 125A Double Pole MCCB built in Adjustable thermal magnetic based release (adjustable O/L, adjustable S/C) of fault breaking capacity 35/36KA (Ics=Icu=100%) upto 240V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended.

-

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

836

47

39292

20

130

2600

... More
Supply of 5 star rated 1200mm sweep ceiling fan, ISI marked, along with copper wound stator, blades, capacitor, downrod etc. but without regulator complete as required.

50

3100

155000

... More
5/6 amps switch

20

103

2060

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

1996

147

293412

... More
Upto 450 mm sweep

50

450

22500

... More
Supplying and fixing call bell/ buzzer suitable for single phase,230 V, including connections, etc complete as required.

18

136

2448

... More
SUB-HEAD-II: DISTRIBUTION BOARDS

-

-

-

... More
2 X 4 sq. mm +1 X 4 sq. mm earth wire

240

334

80160

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

30

1362

40860

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

30

32

960

... More
Space only for 1 No. Minimum diamension of 400MM (H) x 300MM(W) or as required size for accomidating the 4No's of Smart Energy Meters, Glass window compartment each with Lock & sealing arrangement including ACP sheet for mounting existing Single Phase Smart/Pre-paid Energy Meter by SEB (PDD) and 2 x 16.0sqmm FR PVC copper power wiring colour coded between Meter and busbar. Name plate should also be provided as per flat numbing provided client.

-

-

-

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.

-

-

-

... More
Meter Panel Board (Typical Floors for Scholars Quarter) as described below

4

40000

160000

... More
SUB-HEAD-IV: EARTHING SYSTEM

-

-

-

... More
TVSS AND BUS BARS FOR EACH SECTION

-

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
2 way 5/6 amps switch

32

148

4736

... More
12 Module (200mmX150mm)

5

547

2735

... More
Providing & installation of 01 No. of 500A FP, ATFM release 50KA, breaking capacity, 75-100% Icu MCCB with spreader link, includinng connections, etc as required, complete in all respetcs.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.