Irrigation And Flood Control Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Irrigation And Flood Control Department - IFC Tender

Civil And Construction
Irrigation Work
Eprocure
Opening Date15 Mar 2022
Closing Date25 Apr 2022
Tender Amount₹ 1,73,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed byEngineer-in-Charge. All kinds of Soil

422

-

188.75

... More
Etra for every additional lift or part thereof in all kinds of soils (2 lifts)

89

-

81.85

... More
Dumping of Nallah stones in horizontal level including cost of stones

216.38

-

616.4

... More
Providing and Laying in position Cement Concrete of specified grade excluding cost of Cantering & Shuttering. All works upto plinth level. 1: 4:8 (1 cement: 4 coarse sand: 8 graded stone agg. 40 mm nominal size

87.1

-

4419.85

... More
1: 2:4 (1 cement: 2 coarse sand: 4 graded stone agg. 20mm nominal size

73.38

-

5877.45

... More
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

165.06

-

8552.85

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

27.34

-

8953.95

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

1818.96

-

573.85

... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

109

-

635.6

... More
Foundations, footings, bases of columns etc. for mass concrete.

8.5

-

262.3

... More
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand)

46

-

6501.2

... More
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level

46

-

1323.65

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

168.36

-

4943.4

... More
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

41.76

-

6344.25

... More
12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand)

127

-

260.05

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):First class kail wood (To be paid as per docket issued by Forest Department)

0.97

-

106894.15

... More
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). First class kail wood (To be paid as per docket issued by Forest Department)

29

-

2784.1

... More
Providing and fixing 30 mm thick factory made laminated veneer lumber glazed shutter conforming to IS: 14616 and TADS 15 : 2001 (Part B), using 4mm thick float glass panes for doors, windows and clerestory windows fixing with ISI marked butt hinges of required size with necessary screws as per directions of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)

29

-

2287.85

... More
Reinforcement for RCC work including straightening, cutting, bending and placing in position and binding all complete job.

12153

-

79.25

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover

8.4

-

3238.2

... More
Providing and fixing ball bearing for rolling shutters.

4

-

483.1

... More
Applying priming coat:With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)

76

-

59.5

... More
Painting with silicon and acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces: One coat

411

-

80.95

... More
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)

158.72

-

91.8

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc complete On concrete work

158.72

-

183.45

... More
Hand-packing of nallah stones in wire-crates; including cost of stones and excluding cost of wire crates

222

-

737.45

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge. Made of G.I. wire of dia 4 mm

180

-

733.5

... More
Applying priming coat: With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel work (second coat)

360

-

28.9

... More
Structural steel work in single section, fixed with or without connecting plate, including nuts/bolts ,cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

1127

-

82.75

... More
Carriage of materials from source to road site by mechanical transport including loading, unloading and stacking. Stone soling from 03 kms

438.35

-

176.57

... More
20 mm agg. + Sand from avg\. 25 kms

700.38

-

393.02

... More
40 mm agg from avg. 25 kms

124.52

-

427.21

... More
Cement/steel fjrom Divisional store shopian avg. 25 kms

179.05

-

349.39

... More
Bricks from Pampore from avg. 35 kms

21850

-

1.28

... More
Extra Carriage of the materails from road site to the actual site of the work by head load 500 M. Stones

438.35

-

635.48

... More
20 mm cr. Agg. + Sand

693.78

-

540.18

... More
40 mm Cr. Agg

85.9

-

583.96

... More
Cement

166.58

-

245.3

14.66

-

526.92

... More
Bricks

21850

-

1.16

... More
Construction of septic tank (10 feet/x12 feet) Incl. earth work excavation M/S lids, PVC Pipes for connection from commade upto septic tank and septic tank upto sockage pit with all necessary bends, traps which ever is required for septic tank incuding 1:3 Mix Cement plaster inside tank and cost of sockage pit 14 feet in deep with cement concrete rings including cost of rings, disposal of excavated material from site upto outside permisis including dressing of site (Complete job)

1

-

-

... More
Supply of B.A wire/crate mesh of specified size 16'x16' with mesh size 4"x4" with Dia.of wire as 4mm including testing of same material and production of necessary testing report from SICOP or any other testing agency approved by Govt as directed by Engineer incharge.(Including all sorts of carriage)

10779

-

-

... More
Design, Manufacture, Supply, Installation, Testing & Commissioning of horizontal centrifugal Pumping unit for LIS NIKLOORA. The pumping unit shall have the following specifications:- A. PUMP:- Discharge = 5.00 Cusec Dynamic Head = 48 Mtr. Speed = 1500 Synchrous Type of pump = Centrifugal Split casing. NPSH Available = 3.0 Mtrs MATERIAL OF CONSTRUCTION: Impeller = Bronze grade LTB2 Impeller Nut = Stainless Steel ASTM 351/CF-8M Casing lines/Wearing Ring= Bronze grade V of IS: 318 Impeller Shaft = Stainless Steel AISI 410 Stuffing Box = Cast Iron Gland = Bronze grade V of IS: 318 Fasteners = High tensile Steel Shaft Sleeve = Bronze grade LTB2 Pump Casing = Close fine grained Cast Iron conforming to IS:210 grade FG200 B. MOTOR:- Type = Three phase, squirrel Cage, Electric Induction Motor Rating = Suitable for 5 cusec 48 mtr head Speed = 1500 (Synchronised). Operating Voltage = 415 + 10 % Volt Frequency = 50 + 3 Hz Class of insulation = F Type of Duty = Continuous Type of enclosure = TEFC. The motor shall confirm to IS: 325 with latest amendments. The pumping unit shall be complete with Mild Steel Base Frame, fabricated as per IS 2062, requisite number of Foundation Bolts, and Pump – Motor Tyre coupling. Third party inspection certificate shall be enclosed with it.

2

-

1250000

... More
Fabrication, providing, installation and testing of 300 mm Nominal Diameter 6.3 mm thick ERW ISI-mark mild steel pipes for suction piping of 02 no pumps as per the following technical specifications: S.No Details Requirement 1 Nominal Diameter = 300 mm 2 Thickness = 6.3 mm 3 Length of the pipe = Pipe shall be in single random length from 4 to 7 meter as per Clause 12.4 of IS 3589 4 Type of welding = ERW 5 Quality of MS plate to be used for manufacture = As per IS 2062 6 Pipe to be manufactured = As per IS 3589 having one longitudinal joint with latest amendments (Grade-Fe410) 7 Hydraulic test pressure = As per 10.1 of IS 3589 8 Working pressure = `14.27 kgf/cm2 9 End preparation = As per 17.1 of IS 3589 where V-groove is to be made by machine-grinding edges of the pipe 10 Type of welding to be used for joining pipes = DC arc welding 11 Tolerances = As per clause 12.3 of IS:3589 Job includes fabrication & installation of 300 mm dia. Mild steel long radius easy bend fabricated out of the supplied pipe. The pipes shall be fitted with M.S plate flanges 28 mm thick and washers, fasteners for end connections and on the foot valve end, totalling 06 nos. per suction pipe. The pipes shall be painted with two coats of anticorrosive bitumastic paint. The installation shall be carried out in accordance with IS 10804.

16

-

7300

... More
Providing & installation of swing type flanged DI foot valve 300mm dia generally conforming to IS 4038. The Specification and construction of the material shall be as under I. Body= Ductile cast iron EN-GJS-400-15 II. Disc= Ductile cast iron EN-GJS-400-15 III. Retaining ring= Steel S235JR IV. Sealing ring= EPDM (Ethylene propylene Diene monomer) V. Hex. Socket Head Cap Screw= Stainless steel A2 VI. Shaft= stainless steel X20cr13 VII. Shaft support= Ductile cast iron EN-GJS-400-15 VIII. Bearing bush= Bronze IX. Hexagonal socket head cap screw= Stainless steel A2 X. O ring= EPDM XI. Hexagonal Socket set Screw= Stainless steel. XII. Busket Strainer= Steel galvanized.

2

-

35450

... More
Fabrication, providing, installation and testing of 250 mm Nominal Diameter 6.3 mm thick ERW ISI-mark mild steel pipes for delivery piping of 02 no. pumps and a common Y-junction joint at the end as per the following technical specifications: S.No Details Requirement 1 Nominal Diameter = 250 mm 2 Thickness = 6.3 mm 3 Length of the pipe = Pipe shall be in single random length from 4 to 7 meter as per Clause 12.4 of IS 3589 4 Type of welding = ERW 5 Quality of MS plate to be used for manufacture = As per IS 2062 6 Pipe to be manufactured = As per IS 3589 having one longitudinal joint with latest amendments (Grade-Fe410) 7 Hydraulic test pressure = As per 10.1 of IS 3589 8 Working pressure = `14.27 kgf/cm2 9 End preparation = As per 17.1 of IS 3589 where V-groove is to be made by machine-grinding edges of the pipe 10 Type of welding to be used for joining pipes = DC arc welding 11 Tolerances = As per clause 12.3 of IS:3589 The delivery pipes shall be fitted with M.S flanges 26 mm thick totalling 05 nos. per delivery pipe with washers, fasteners for pipe fittings and end connections. The job also includes fabrication of bends for delivery line and before common joint out of the supplied pipe and fitting the common junction end with 350 mm ND pipe (departmentally available at site) as per the instructions of engineer in charge. The pipes shall be painted with two coats of anticorrosive bitumastic paint. The installation shall be carried out in accordance with IS 10804.

30

-

5650

... More
Manufacturing, providing and installation of 300mm dia x200mm dia and 400mm long eccentric reducer fabricated out of 7.1 mm thick Mild steel plate duly flanged on both sides. The reducer is to be fitted on the suction side of pumping equipment. The specifications of M.S flange on Reduced and enlarged side of increaser shall be as under: - a). Reduced side flange: - i. Material = Mild steel ii. Nominal dia. = 200 mm or as per pump inlet iv. Thickness = 24 mm b). Enlarged side flange: - i. Material = Mild steel ii. Nominal dia. = 300mm iv, Thickness = 28 mm The job includes providing and fitting of nuts-and-bolts washers etc. and painting in one coat of steel primer followed by 02 coats of bituminous paint.

2

-

11000

... More
Manufacturing, providing and installation of 200 mm dia x250 mm dia and 400 mm long concentric increaser fabricated out of 7.1 mm thick Mild steel plate duly flanged on both sides. The increaser is to be fitted on the delivery side of pumping equipment. The specifications of M.S flange on Reduced and enlarged side of increaser shall be as under: - a). Reduced side flange: - i. Material = Mild steel ii. Nominal dia. = 200 mm or as per pump outlet iii. Thickness = 24 mm b). Enlarged side flange: - i. Material = Mild steel ii. Nominal dia. = 250 mm iii Thickness = 26 mm The job includes providing and fitting of nuts-and-bolts washers etc. and painting in one coat of steel primerfollowed by 02 coats of bituminous paint.

2

-

3500

... More
Providing & installation of flanged PN 1.6 DI Silpon joint/Dismantling joint 250mm dia I. Flanged pipe long= Ductile cast iron EN-GJS-400-15 II. Flanged pipe short= Ductile cast iron EN-GJS-400-15 III. Retaining flange= Steel S235 JR IV. Sealing ring= EPDM V. Stud bolt= Steel galvanized IS 1367 VI. Stud nut= Steel galvanized IS 1367 The job also includes providing and fitting of nuts, bolts and rubber washers. The job includes testing of same at full load

2

-

55000

... More
Supply installation, testing and commissioning of DN 250, PN 1.6 sluice valves generally conforming to IS 14846 or equivalent international standard to following specification: - Material of construction: - a) Body, Bonnet : Ductile iron b) Wedge : Ductile iron c) Spindle/Stem :St Steel as per IS 6603 or ASTMA 276 or IS 1570 d) Stem nut : LTB2 high tensile Brass e) Bonnet Gasket : Neoprene rubber f) Flange drilling: IS 1538 Table 4/ 5. The job also includes providing and fitting of nuts,bolts washers and fastners. The job includes testing of same at full load.

2

-

53500

... More
Supply installation testing and commissioning of Reflux valve 250mm dia ISI marked PN 1.6 generally conforming to manufacturing as per IS-5312 Part-1 of 2004 with latest amendments and flange connections as per IS 1538/BIS 4504. Body: Ductile Iron Bonnet: Ductile Iron Disc: Ductile Iron Plug: Brass Surface Protection: Electro static epoxy powder coating. The job includes fabrication of By-pass arrangement for 250 mm dia NRV as under: - i) Creating holes of 25 mm using gas cutter. ii) Providing and fitting of 25 mm dia steel pipe heavy class of required length along with 02 nos. of elbows iii) Providing and fitting of 01 no. SS ball valve 25 mm of reputed make

2

-

58500

... More
Providing, Fitting, Installation, Testing and Commissioning of priming Sewage submersible pumps (01 No) and 1 no. unit as standby each of 01 HP capacity Kirloskar/Crompton/KSB/Mather Platt/ equivalent make for priming purpose of three pumping units with following specifications: a. Type ------ Sewage submersible b. Head ------ 10 Mtrs. c. Phase ------ 1 phase d. Discharge ------ 200-250 litres /Min e. Power ------ 01 HP/0.75 KW f. Speed ------ 3000 RPM (synchronous) g. Voltage ------220 +/-10% V The priming pump shall be suitable for operation under submerged conditions and shall be suitable for wide water level fluctuations taking place in suction side. The priming pump shall be water immersed and fitted with good quality oil seal and an automatic water level float for tripping purpose during low water level. The job shall include providing /fitting of all the G.I/ MS Black pipes 50 mm NB C-class as per IS 1239 (Approx. =60rft.) as per the out let of the priming pump and fittings like ball valve, Nipples, flanges/sockets, Tees, Elbows/Bends, & other allied fittings as required for priming of the two pumping units and complete installation as required. The job also includes suitable capacity compact starter/ controller and P/F of 10mm sq. Submersible cable=20 metres. The job also includes the separate self priming 5 Hp monoblock type priming pump as standby unit with necessary fixtures and fitting

1

-

115000

... More
Providing, Fitting, Installation, Testing and Commissioning of priming Sewage submersible pumps (01 No) and 1 no. unit as standby each of 01 HP capacity Kirloskar/Crompton/KSB/Mather Platt/ equivalent make for priming purpose of three pumping units with following specifications: a. Type ------ Sewage submersible b. Head ------ 10 Mtrs. c. Phase ------ 1 phase d. Discharge ------ 200-250 litres /Min e. Power ------ 01 HP/0.75 KW f. Speed ------ 3000 RPM (synchronous) g. Voltage ------220 +/-10% V The priming pump shall be suitable for operation under submerged conditions and shall be suitable for wide water level fluctuations taking place in suction side. The priming pump shall be water immersed and fitted with good quality oil seal and an automatic water level float for tripping purpose during low water level. The job shall include providing /fitting of all the G.I/ MS Black pipes 50 mm NB C-class as per IS 1239 (Approx. =60rft.) as per the out let of the priming pump and fittings like ball valve, Nipples, flanges/sockets, Tees, Elbows/Bends, & other allied fittings as required for priming of the two pumping units and complete installation as required. The job also includes suitable capacity compact starter/ controller and P/F of 10mm sq. Submersible cable=20 metres. The job also includes the separate self priming 5 Hp monoblock type priming pump as standby unit with necessary fixtures and fitting

3

-

153200

... More
Fabrication, providing and fitting of 350 mm ND mild steel dismantling joint with longitudinal elongation up to 50mm and nominal length of 260mm fabricated out of MS plate 10mm duly rolled in perfect circular shape and turned to proper size. The specifications are as under: - No.1- Pipe piece: - The number 1 pipe piece with flange on one side and welded in two layers. The welding joint should be smooth, flawless and continuous. No.2-Body piece: - The number 2 body piece 200 mm long shall be flanged on one side and turned on lathe machine to the size of outer dia of pipe piece. NO.3- Retainer flange: - One number retainer flange shall be finished on both sides to accommodate EPDM seal/ RI cloth with body piece making the joint leak proof. The dismantling joint is to be fitted to DPCV on one side and to the rising main (by mating flange) on other side. The dismantling joint shall be painted with two coats of Red Oxide Metal Primer followed by the two coats of Black Bituminous Paint. The job also includes providing and fitting of M.S fasteners, RI cloth, Washers, Rubber Gaskets, etc. All flanges shall be as per IS 6392 Table 17.

3

-

65000

... More
Fabrication, providing, fitting and testing of by-pass arrangement around the dual plate check valve and dismantling joint assembly. The job shall comprise of cutting of holes at two specified spots on the rising main, providing and welding of 50mm NB GI/ MS black pipe heavy class to the rising main including one side flanged bends with matching flanges 4 No, ball valves -01 No. 50 mm size

3

-

8100

... More
Providing, installation, testing and commissioning PN 1.6 rating 80mm DI double acting air release valve with in-built isolating valve (Type: DS1) conforming to IS 14845 Material Specifications: Body, cover, valve, valve holder, cowl, gland, cap, joint support ring ----- Ductile iron Stem ------- High tensile brass Or Stainless steel Floats ------ Timber core with coating Nuts & Bolts ------ Carbon steel Installation: These air release valves are to be fitted to 350 mm dia MS rising main by way of flanged end connections and pipe pieces

2

-

36500

... More
Fabrication, providing and fitting of 350 mm ND Mild steel pipe expansion joint with longitudinal elongation upto 100 mm and nominal length of approximate 1000 mm fabricated out of 10 mm M.S plate duly rolled in perfect circular shape and turned to proper size. The job includes providing and fitting of matching MS flanges of nominal dia 350 mm as per IS 6392 (table 17) to the rising main on both ends of joint. The flanged joints shall be made leak proof by way of insertion of rubber insertion cloth of superior quality and of suitable thickness The specifications are as under: - NO.I- Socket :-- The socket shall be fabricated out of MS plate of 10 mm thickness and offset ND as 3500 mm, 375 mm each piece 150 mm long duly welded with each other. The 375 mm central piece shall be turned and finished to proper size to accommodate the spigot with its easy movement of to and fro during expansion and contraction NO.II- Spigot The spigot shall be fabricated out of 10 mm thick MS plate duly rolled in perfectly having approx. length of 500 mm. This piece shall be turned to accurate size on the lathe machine to give easy movement during operation. NO.III- Gland - The gland shall be fabricated out of 10 mm MS plate having approx. length of 150 mm duly turned to mover over the spigot to make the packing material tight to avoid leakage. The dismantling Expansion joint is to be fitted on pipe. It shall be painted with one coat of Red Oxide Metal Primer followed by two coats of Black Bituminous paint. The job also includes providing and fitting of 2 no. flanges, M.S fasteners, RI Cloth Washers/ Rubber Gaskets, etc. All flange dimensions shall be as per IS 6392 Table 17.

2

-

75000

... More
Fabrication, providing and fitting of 350 mm Mild steel flap valve to be fitted to the Main Rising main pipe line. The flap valve shall be fabricated out of Mild steel plate and shall be of the following specifications: - a. Thickness of body of flap valve = 8mm b. Flange thickness = 18mm c. Thickness of flap plate = 24mm d. Length of valve from upper side= 300mm e. Length of flap valve from lower side = 450mm The flap valve shall be fitted with Mild steel ring all along the periphery on which the flap plate shall rest. A suitable heavy duty Mild steel hinges shall be fitted on the top of the valve. The flap valve shall be painted with one coat of steel primer& two coats of bituminous paint. The job also includes providing and fitting of nuts and bolts and rubber insertion cloth washers etc.

1

-

21500

... More
Fabrication, providing and fitting of working platform out of ISMB 200 to be erected on the sump to form the rectangular rigid frame structure 8 m x 1.5 m. ISMB 200: - {(2x8 m) +(4x2) m=20 mtrs The ISMB-200 main girder shall be welded together through the bracings/stiffeners of ISMC 75x40mm at 4 spots of 2 mtr length each The job includes Providing and fitting of M.S. chequered plate 6mm thick to the rectangular ISMB frame of size 8x2 mtr with necessary bracings out of ISA 50x50x6. The job also includes the formation of suitable opening with hinges at the requisite spots for installation of suction pipes. The job is to carried out as per the instructions of engineer in-charge. The steel work shall be applied with a coat of approved steel primer.

1314

-

140

... More
Fabrication, providing, fitting and installation of 1-ton capacity sump gantry. The job comprises of the following specifications process of fabrication and involvement of material: - a). Vertical supports: - Fabrication, providing and installation of gantry vertical supports (two Nos.) to be fabricated out of Mild steel angle Iron of size 50x50x6mm the posts shall have to be fabricated as per drawing. The vertical posts shall be fabricated in four pieces of angle iron having 5 Mtrs effective Height and its strengthening /bracing by horizontal members to be placed after every 3’.0 and diagonal members as per requirement out of same angle section as used with the vertical members the size of the angle Iron post shall be 18”x18” at the bottom and 12”x12” at the top. the vertical angle iron posts shall be provided and welded with Mild steel plate having 10mm thickness welded at the bottom and top duly drilled with suitable diameter holes. The Bottom portion of the vertical support shall be embedded into the cement concrete block of suitable size to be laid in the ratio of 1;2;4. The posts thus fabricated shall be erected at the two sides of the sump gantry. b). Gantry Beam: - Providing and fitting of main I beam (Horizontal) of size ISMB-250 having total length of 8.5 Mtrs shall also be fitted with Mild steel plate of the same size i.e., 12”x12”,10mm thick, with nuts and bolts and welding as well. The job also includes providing and fitting of nuts and bolts for fixing of plates of the horizontal beam and vertical posts plates.

656

-

140

... More
Monorail and chain pulley block: - Providing and fitting of 1-ton capacity travelling trolley manorial of spur gear type and 1-ton capacity chain pulley block having 6mtrs. Lift. The chain pulley block and the travelling trolley shall be of medium duty.

1

-

35500

... More
Design, manufacture, supply, erection, testing and commissioning of 3-ton capacity overhead monorail travelling crane for handling of electro-mechanical equipment at LIS Nikloora with following specifications. a. Basic Crane Requirement. i. Capacity: 3 Ton ii. Length of runway: 10.00 metres iii. Length of bridge girder: 7.00 metres b. Bridge Girder: Bridge girder 7.00 Meters long fabricated out of ISMB 300 section is to be fitted with two No. end carriages fabricated out of ISMC 150 section and other suitable MS members. Each end carriage is fitted with two No. MS wheels of suitable size mounted on suitable ball bearings. The two end carriages are coupled with each other by way of MS shaft and suitable gear reduction mechanism. The shaft is supported on Plummer blocks held by MS brackets. These brackets are to be welded to the bridge girder. A pulley fitted with the shaft is provided with an endless chain of 6 Meters to facilitate the movement of end carriage along with bridge girder. c. Runway Girder: Runway girder (2 Nos.) 10.00 meters long fabricated out of ISMB 200 with 25 mm M.S square bar welded on upper flange for movement of drive / driven wheels. The square bar is aligned perfectly and finished smoothly by machining. Two No. of ISMC 150 braces are provided for connecting end columns of each row with the shed. d. Monorail: One unit 3-Ton capacity heavy duty monorail, suitable to operate through endless chain of 6 meters is mounted on lower flange of bridge girder to facilitate travelling movement of hoist load. The movement in longitudinal and transverse direction is limited by way of providing and fitting 4 No. suitable MS end stoppers of adequate strength to absorb the impact of moving monorail (with load). e. Hoist/ Chain Pulley Block: 3 Ton 6m lift capacity chain pulley block of spur gear type mounted on monorail travelling trolley and operated from floor through an endless chain The whole job and its components are to be executed as per relevant IS Code.

1

-

235000

... More
Fabrication, providing, installation and fitting of Mild steel Trash rack to be fitted on the mouth of intake channel at Nikloora LIS. The trash rack shall be fitted on cement concrete walls of the intake channel.The size of the trash rack shall be 2.10x2.10 mts and shall be in the form of gratings. The frame of the trash rack shall be fabricated out of Mild steel channel of size ISMC-100 and a stiffener of M.S angle Iron of size 50x50x6mm shall have to be fitted in between the trash rack for its additional strength. The frame shall be fitted with Mild Steel Flat Iron strips of size 50x6mm welded vertically at a spacing of 1.5” from centre to centre. The steel work shall be applied with one coat of steel primer.

382

-

140

... More
Painting: Painting with synthetic enamel paint of approved brand, shade and manufacture to give an even shade in two coats on new work 1. Working platform, trash rack, all mechanical works 2. Gantry The complete overhead travelling crane comprising of bridge girder, runway girder, end carriages and other fixtures are painted with one coat of steel primer and two coats of super enamel paint of yellow shade of reputed make. 3. Sump gantry: The complete sump gantry shall be painted with one coat of steel primer and with two coats of super enamel paint with the following shades. Vertical posts- black shade: - I beam- yellow.

173.5

-

210

... More
Scope: Design, manufacturing, providing, fitting, testing & commissioning of 200 HP FASD Starter. The Star-delta Starter Panel shall be fabricated out of 2 mm CRCA Sheets Modular, compartmentalized, free Standing, floor Mounting, front hinged doors for indoor use, removable bottom gland plates for incoming cables, dust and vermin proof (IP: 42 protection) with TP Aluminum Buses, complete with connection, internal wiring, name plates, painting etc. generally as per details furnished below: Rated Voltage of the Panel ----- 410 ± 10% Volts Frequency ----- 50 HZ No of Phases ----- Three Enclosure Details: Free Standing, Floor mounted compartmentalized design. Material ----- CRS Thickness of sheet steel used ----- 2 mm Application ----- Indoor Cable Entry ----- Bottom Painting ----- Shade Siemens grey (spray painted). I) Distribution bus bar Type -----Electric grade Al with red, blue & yellow tapings of adequate section. Rating ----- 400 Amp II) Starters (FASD) Power Specification -----3 phase, 415 ± 10% v & 50 Hz Contactors : Main Contactor ----- 200 Amp Star Contactor ----- 100 Amp Delta Contactor ----- 200 Amp Timer ----- Star Delta Electronic Qty ----- 1 No’s Phase failure Relay Qty ----- 1 No. III) Protection Details: (a) Thermal Over Load Relay CT operated of suitable rating.) ---- 01 No (b) Phase failure/ Phase Reversal Relay/motor protection relay/ single phase preventer ----- 01 No IV) Metering Details: (a) Digital voltmeter S/S operated (1 No) (b) Digital Ammeters 0-300 Amp (1 No) - S/S CT operated

2

-

185000

... More
Providing, installation, testing of 630 Amp, 3 phase LT motor control panel Providing, installation, testing of 630 Amp, 3 phase LT motor control panel in door type totally enclosed dust and vermin free internally wired, body fabricated out of 14-gauge sheets duly alkalized and painted with enamel paint, The LT panel shall comprise of the following and should operate on 3-phase AC supply 415+10% installed at LIS Nikloora. The main features are • Incoming Feeder • Outgoing Feeder • Auxiliary Feeder INCOMING FEEDER: -One no. incoming feeder consisting of TPN air insulated 630 Ampere Al.Bus-bar arrangement. The incoming feeder shall house one no. 4-Pole 630 Amp 50 KA breaking capacity with magneto thermal overload protection and manual draw. The front of the panel shall have the following Digital type meters mounted on it: • 01 No. Amp Meter,96 mm2size 0-400Amp range with 4way selector switch,. • 01 set of three indicating neon bulbs. • The panel shall be channel mounted and lifting hooks to be provided. • 01 no. Volt meter, 96 mm2 size, 0-500 Volt range with 4-way selector switch,. • Frequency meter of 47-53 HZ range 1 No CT’s of adequate range for Ampere meter /Kw-Hr Meter /frequency meter. OUT GOING FEEDER:02 No. outgoing feeders, each outgoing feeder shall house the following; • 02 No.MCCB 400 Amp, D-Sine 50 KA breaking capacity with magneto thermal overload protection system of suitable range for 150 HP motor. – 03 Pole. [L&T/Siemens/Schneider /equivalent Make] • Air insulated Aluminium Bus Bar arrangement of suitable rating. The front of the panel shall have the following digital type meters mounted on it. • 01 No Ampere meter, 96mm2 size, 0-500 Ampere range L&T/Rishabh /equivalent make with 4-way selector switch, KAY CEE Make. • 01 Set of three indicating neon bulbs. • 01 No. Voltmeter, 96mm2size, 0–500-volt range AE/L&T/Rishabh /equivalent make with 4-way selector switch, KAY CEE make. • CT’s of adequate range for Ampere meter. • Complete control wiring for protection release AUXILIARY FEEDER: One No, Auxiliary compartment shall have 01 No. MCCB of 100A capacity, 4–Pole, 36 KA(L&T/ Havells/ Siemens/ Equivalent make) and aluminium bas bar arrangement of adequate rating for priming pump and other auxiliary requirements of the pump house. The LT Panel shall also be provided with 02 No. Earthning terminals and lifting hooks be provided for incoming and outgoing cable as above, 32 amp DP MCB for Priming motor and 63 Amp Isolator for electrification/ Lights Etc. The control panel should be fully inbuilt with all devices for smooth operation of the 2 No. pumping equipment of 150HP capacity each.

1

-

285000

... More
Manufacture, Supply, Installation and commissioning and testing at site 250 KVA Capacity Copper wound voltage stabilizer. The stabilizer shall be manually operated, oil cooled suitable for working on 3 phases 50± HZ AC voltage. The core shall be contained in a rectangular container made out of 3mm thick Mild Steel plate. The container shall be spray painted in two coats of steel primer both inside and outside and with two coats of super enamel paint of grey shade outside the container. The box shall be provided with suitable cooling pipes/fins to dissipate the heat generated. Lifting hooks of proper size for lifting stabilizer shall be provided on the top of the tank. The container of the stabilizer shall be mounted on wheels for easy shifting/positioning as and when required. Copper Srtips of suitable size shall be used for winding and fibre glass insulating material shall be used for insulating of copper wire. The core of the stabilizer shall be fabricated out of CRNGO cut to the specified shape and size and then tightened securely. The stabilizer shall have suitable insulated lugs of appropriate size of cable connection. The indicating glass of the transformer oil shall also be provided on the stabilizer body. Specifications. Voltage Range = Input = 240-460 volts Output = 415±volts Tape Changer = Manually operated balance type changer of 6 tapings with tape position Indicator. Tape No: - 1 =Step down by not more than 50 volts. Tape No: - 2 = line voltage. Tape No: - 3-6 =These tapes shall be used to increase voltage in the range of 240- 460 volts to 400-415volts The stabilizer shall be provide with a free standing type control panel made out of sheet metal dust and vermin proof internally wired having following accessories. a). Two number voltmeter 96 mm square Digital type 0-500 volts,of l&t/Rishab/equivalent make one each on incoming and outgoing circuits. The voltmeter shall be with phase selection option. b). A set of indicating lamps for 3 phase complete with fusing both in primary and secondary side of the transformer. c). Red and green lamps for OFF/On display. The stabilizer shall be filled with fresh transformer oil up to the required level. All the accessories and meters shall confirm to relevant ISI standards. The voltage stabilizer shall be tested on full load as directed by engineer incharge.

2

-

260000

... More
Providing, Supply, Laying and Fitting of XLPE insulated 1.1KV 1-core 240 sqmm un-armoured Almuinum cable covered with suitable PVC/ rubber sleeves for cabling of electrical equipment. The job includes crimping of the terminal ends of the conductor with hydraulic tool and providing and fitting of corresponding copper lugs. The conductor shall be of reputed make preferably Grand lays/ Havells/ Polycab/ equivalent and shall be as per relevant IS specifications.

300

-

500

... More
Providing/ supply/ installation &laying of single core XLPE armoured 1C 630 sq mm aluminium cable conforming to IS-7098 Part 2for use with main Service line. The cable shall be drawn in air from Electrical Sub-station to main LT panel. The job also includes crimping of terminal ends of the cable with Hydraulic tool and providing & fitting of 630sqmm Aluminium power conductor lugs of reputed make preferably “DOWELLS” make. The Cable Shall be of reputed make preferably Grandlays /Havells/ Polycab/ equivalent make.

90

-

1150

... More
Providing and fitting of APFC panel to be connected in central compensation modeat LIS Nikloora. Capacitors shall be provided to work with no load and on load. Specifications of APFC panel: • Rating of APFC Panel:85.5 kVAr with Auto & manual switching • Frequency: 50 Hz • No. of Phases: 3 • Enclosure details: o Free Standing, Floor mounted, Indoor application o Material: CRCA o Thickness of Sheet Steel Used: Frame/ door(s) -2.0mm; Partitions-1.6mm o Protection: IP-42 or higher o The panel shall be supported with suitable section base frame at bottom. o Adequate lifting facilities shall be provided. o Earthing: The panel shall be provided with earthing terminals of min. M-10 size on both sides of the panel. o Painting: Powder coated shade Siemens grey • Bus-bar Detail o Material: Aluminium bus bar system of electrolytic grade suitable for the short time rating of 35kA for 1 sec o Busbar support: SMC Insulation • APFC Relay o Microprocessor based (08 Step): 1 No. (Schneider/ L&T/ Meher/ BELUK) • Switchgear o Incomer: MCCB3P 500A 50kA breaking capacity -1 No. conforming to IS: 13947 (L&T/ABB/Schneider) o Outgoing steps - Contactors (capacitor duty) (L&T/ ABB/ Schneider) & MCBs/ fuses • Capacitors o Type: Standard Duty(L&T/ABB/Schneider) • Allied instrumentation o Analog Ammeter with CTs (0-200A): 1 No. (Rishab/ C&S) o Analog Voltmeter with CTs (0-500V): 1 No. (Rishab/ C&S) o Ammeter SS/ Voltmeter SS: 01 Each (Salzer/ L&T/ C&S) o Auto/ Off/ Manual Switch 1 No. (Salzer/ L&T/ C&S) o Phase Indicating Lamps: 3 Nos. (L&T/ Esbee/Teknic/ C&S) o External Current Transformer: 3 Nos. tape wound type shall be capable of withstanding the rated fault current of the system for 1 second (L&T/ RECISE/ KALPA/ AE/ Rishabh) o Timer/s: ON Delay (GIC/ other reputed make) o Outgoing feeder Indicating Lamps (ON.OFF) 2 Nos. each (L&T/Esbee/Teknic/ C&S) Technical Features of Switchgear Components 1. Low voltage MPP Capacitors o Type: The capacitor element shall comprise of self-healing, metallized polypropylene film having internal fuse to limit pressure in the container. o Standard: The capacitors shall conform to IS 13340 o Rated Voltage:440 V o Rated frequency: 50 Hz with a frequency variation of ± 5% o Number of Phases: 3 ph; delta connected o Temperature category: Upto 50°C o Watt loss per kVAr (Di-electric): upto 0.5 Watts/kVAr, o Discharge device: internal resistor provided with discharging to 50V in 60 sec or less time o Permissible limit of unbalance: 5% o Type of container: metallic aluminum OR CRCA 2. Contactors: The contactors shall be of capacitor duty with special inrush current limiting arrangement suitable for kVAr rating. Maximum inrush current at any step shall be 3-4 times the rated current. Contactor coil shall operate satisfactorily between 85% to 110% and drop out at less than 60%. 3.Automatic Power Factor Correction Relay: The panel shall be provided with Microprocessor based APFC relay having steps with facility for setting target PF range in the form of high and low step indication, low current indication and auto-manual selection. LED display shall be provided to indicate existing power factor. The relay should also provide overvoltage protection up to 10% of rated voltage and lead power factors are completely eliminated. 4. Control wiring: Suitable control wiring shall be provided in PVC duct as per requirement with ferrule numbers shall be numbered for ease in connection. The control supply shall be tapped after the mains incomer MCCB. Control circuit shall have protection fuses/ MCBs 5. Power cabling: Suitable sized aluminium unarmoured power cable (Finolex/ KEI/ Polycab/ Gloster/ Havells) with lugs shall be provided to connect the capacitance with load.

1

-

150000

... More
Electrification of pump house: - Providing, fitting and installation of 50-watt LED flood lights inside and outside the pump house walls and where ever necessary as per requirement, comprising of brackets and necessary fixtures reqd. for fitting the flood lights etc. Make: BAJAJ/Havells /Philips/Equivalent make. The job includes wiring of required size & S/W of required amperage.

10

-

3500

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

14

-

750

... More
Wiring for heating point 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with switch socket combine, phenolic laminated sheet, suitable size MS box and earthing the point with 2.5 sq.mm FRLS PVC insulated cop2.5conductor single core cable etc. as required.

3

-

1100

... More
Fabrication, providing and fitting of sub-main panel board of size 2’x2’. The frame of the board shall be fabricated out of 35x35x5mm M.S angle iron and fitted with ply sheet 12mm thick and face covered with ACC sheets. The panel board shall have suitable legs which shall have to be embedded into the pump house wall.

1

-

300

... More
Providing & fitting of 1200mm sweep ceiling fan. (Havells/ Orient/ Bajaj)

1

-

2500

... More
Providing & fitting of 300mm sweep exhaust fan. (Havells/ Orient/ Bajaj)

2

-

2200

... More
LED 9-watt lamps (Havells/ Syska /Wipro/ Philips)

11

-

150

... More
Providing and fitting of service line for electrification of pump house and station premises. The service line shall be 2 core-16 mm sq. Armoured Aluminium XLPE cable including suitable size & rating of thimbles to be drawn from electric transformer sub-station/main panel board to sub-main panel board or as per requirement.

100

-

160

... More
Complete earthing of the electrification of pump house and station premises which includes excavation of earthen pit of size 3’.0x3’.0 and 5’.0 deep providing and embedding of 12” dia. 5mm thick copper plate fitted with G.I wire sufficient quantity of salts and charcoal in the pit. The Jumper wire shall be connected with all electrical fixtures of electrification.

1

-

500

... More
Providing and fitting of MCBs for electrical circuit with 63A as incomer 0ne no.10- 32A MCB out going 6 no.s for heating circuits and lighting systems. The MCBs shall be mounted on a MCB distribution box 10-way fitted on panel board for central control of electrification of pump house and station premises. (MCB makes: Havells/ Legrand/ L&T/ Schneider/ equivalent)

1

-

5500

... More
Providing and fitting of 63 Amp. Capacity 4-pole change over switch along with allied wiring for the lighting system of the pump house. The changeover switch shall be of reputed make (Anchor/ Havells/ L&T/ SSK).

1

-

7100

... More
Providing and fitting of 7.5 KVA fully automatic oil-cooled voltage stabilizer ranging from 90-300 Volts giving output voltage of 200-230 Volts. The job also includes P/F of 12-volt 25 plate DC battery of 150 AH (Exide) along with 0.6KVA sine wave Inverter (Microtek/ APC make) and trolley

1

-

57500

... More
Providing of following accessories for watch and ward staff, 1. Utensils complete set (05kgs) including pressure cooker (Prestige make) 02 nos. 5 Litre capacity each 2. Gas stove (2-burner) along with double gas connection filled and rubber hose 3. Matting 12mm thermocol 12’x12’ and excel matting 12’x12’ 01No.each 4. Single Beddings – 02 sets. (including Quilt, mattress, bedsheet, pillow,mink blankets) 5. Heavy duty plastic chairs 08 nos. Including table 02 nos. (Nilkamal/ Supreme/ Samruddhi)

1

-

50000

... More
Plate earthing of electrical equipment at site as per IS 3043. The equipment which shall be earthed at site are given as under: - 630 Amp. LT panel = 1 No. 200 HP FASD starters = 2 Nos. 250 KVA capacity copper wound voltage stabilizer = 2 Nos. 150 HPsq. cage Induction motors = 2 Nos. PF correction panel – 01 no. The earthing of the above equipment involves following processes: - Earthing pit (02 nos.) The pit size shall be 3’.0x3’.0 and 10’.0 deep. The pit shall be along on back sides of the pump house at suitable distance away from the pump wall. A GI plate of size of 600x600x6mm shall be placed in the excavated pit. The plate shall be embedded in charcoal and common salt laid in layers. The plate shall be properly bolted to GI strip of sufficient length for connecting the plate to the main strip through a GI pipe 32mm NB medium class with funnel at the top. The pit shall be refilled back with excavated earth and its ramming.

1

-

14000

... More
GI strip for earthing The earthing GI strip shall be of size 25x6mm and laid from the connecting points on the electrical equipment upto a common point and then further to earthing pits. All the electrical equipment shall be connected to the main strip by means of proper bolting arrangements. The quantity of strip required for the station shall be as per site requirement.

30

-

140

... More
Providing and laying at site of high voltage synthetic insulating mats as floor covering around electro/mechanical for safe guarding life and limb of workmen due to possible leakage of current and short circuiting. The mats shall have the following characteristics/technical specifications: i) Confirming to IS -15652-2006 with latest amendments if any ii) Thickness- 2.5mm iii) Width – 1 Mtr iv) Length 2 mtr v) Anti- skid, embossing on upper surface shall have small aberration to avoid slipper effects while lower surface shall be plane. vi) Material-PVC elastomer vii) Application: suitable for both AC and DC electric installations. viii) Ratings- AC (RAM) 11 KV, DC volt 240 ix) Class – B x) Color- Black/RED/ Orange/Blue xi) Acceptable make- Safe volt/Dozz/Zenith/ equivalent The mats besides above shall be moisture proof, fire retardant, no adverse effect of acid, alkalis, diesel oil and T oil and is to be fixed with floor at LIS Nikloora.

8

-

2400

... More
Supply of Fire extinguisher ABC powder type (stored pressure) of 4 kg capacity with following feature 1) IS certified as per IS 15683, 2) Operating temperature 0 to 55 degrees with MAP powder complete in all respects suitable for all types of fires particularly electrical fires. 3) Wall hook and discharge pipe shall be supplied along with cylinder

4

-

2500

... More
Tool Kit: - The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of Taparia make: 1. Double ended Spanner of Size (6/7 to 30/32) (01 complete set) 2. Ring Spanner Set of Size (12/13 to 30/32) (01 complete set) 3. Cutting Pliers, 8 inch: (03 No`s) 4. Nose Pliers 8 inch: (03 No`s) 5. Screw Driver 12 inch / 8 Inch / 6 Inch/4 inch :( 02 No`s Each Size) 6. Hammer, I Kg and ½ kg: (01 No each) 7. Heavy duty Pipe Wrench 12 inch&8 inch: (02 No’s each) 8. Bearing puller (sizes 6 & 8): (01 no. each) 9. Spirit level (600mm): 01 no. 10. Digital clampmeter (400A AC range): 01 no. (Meco/Rishabh/ Fluke make) 11. Vernier calipers (150mm digital display):01 no. 12. Altimeter of following specifications 4000 (Range: 0-2500mm, Resolution 1m) Make: BARIGO / HTC 13. Aluminium ladder telescopic type 20ft

1

-

33500

... More
Providing, Installation, Testing And Commissioning of oil immersed naturally air cooled (TYPE ONAN) , Outdoor type, three phase, 50 Hz , 11KV/440V-250V step down distribution transformer copper Wound of 400 KVA Level-2 capacity confirming to IS-1180 at Lift Irrigation Scheme Nikloora, The transformer shall be provided with all necessary accessories like Breather, Horn gap, Lifting Lug, And suitable name plate duly embossed/Engraved. The H.T transformer shall be manufactured /supplied incompliance with latest relevant IEC/IEEE/IS Standards. The technical specifications of the H. T. Transformer shall be as under. I. Standard :IS-1180 (Part-1) : 2014 II. Type : Outdoor, Oil Cooled, 3 Phase & Neutral III. Energy Efficiency Level : 2 IV. KVA Rating : 400 KVA V. Rated Voltage H.V. : 11000 Volts L.V : 415 +-10%Volt. VI. Frequency : 50 HZ VII. Type of cooling : Naturally air cooled VIII. Primary Winding Conductor : DPC Copper IX. Secondary Winding Conductor : DPC Copper The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a Test Certificate shall be provided before installation.

1

-

850000

... More
P/Erection of 9 Mtr long M S Tubular poles (410 - SP 31 ). The job also includes painting of poles in silver color over priming coat, grouting of poles in CC blocks of (1:2:4) mix, P/F of D shackles for holding ABC cable, nuts and bolts etc. the job also includes spiral earthing of poles with GI wire.

15

-

23500

... More
Providing and fitting of polymer type insulators including all fittings

45

-

350

... More
P/F of guy wire with insulator and anchor, complete in all respects.

10

-

750

... More
P/F of 10’ long 15 No ISMC 100 channels for transformer bed complete in all aspects and as per latest IS Standards.

1

-

60000

... More
P/F of 8’ long ISMC 75 channels with nuts and bolts for fitment of link set, D/O set & lightening arrestor set etc. The job also includes painting of poles in silver colour over priming coat ( 06 for GO switch, 02 for DO set and 02 for LA set)

10

-

2470

... More
P/F 3 phase 11 KVA heavy duty (G.O. Switch) complete with links and lever operated mechanism, nuts and bolts and in all complete respects.

2

-

12000

... More
P/F 3 phase 11 KVA heavy duty drop out fuse set

1

-

3500

... More
P/F of 9 KV, 10 KA lightening arrestor set ( Station type )

1

-

6000

... More
Providing, laying, stringing and binding of conductor ACSR 0.05

1.5

-

51550

... More
Providing and fixing of D Clamps with nuts and all accessorise in all respects

60

-

250

... More
Providing and fitting of ant climbing devices with danger plates on poles

15

-

355

... More
P/F of 630 amps. 4 – Pole MCCB having breaking capacity of 50 ka of L& T, Havell’s make for outdoor use. The MCCB shall be enclosed in sheet metal casing of appropriate thickness and c/w all fixtures.

1

-

65000

... More
Providing and fitting of prodigy LT Meter complete in all respects to the above mentioned station.

1

-

35000

... More
P/F of the arrangement (Belt) to hold the transformer firmly and securely to the substation. It is to be fabricated out of ISA(40x40x5)mm C/w nuts & bolts

1

-

2200

... More
Complete earthing of substation using suitable size and thickness Gi strip, baby insulators and GI plates ( 01 No for transformer body, 01 No for neutral and 01 No for LA set)

3

-

2000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.