Border Security Force Tender

... More
The BSF has issued a formal invitation for competitive bids for the Border Security Force project, for Repair And Upgradation Of Gen Room Of 148 Bn Bsf Under Shq Bsf Jammu. Sh Internal Electrification in Jammu, Jammu & Kashmir, with an estimated contract value of Rs. 48,586. The bid opening date for this tender is 24-12-2024 and the last date for bid submission is 04-01-2025. Interested bidders for Border Security Force tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Border Security Force - BSF Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 Dec 2024
Closing Date4 Jan 2025
Tender Amount₹ 48,586 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. i) 16 way, Double door

1

-

-

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i)Single pole

8

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. i) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire

15

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/reces including cutting the wall and making good the same in case of recessed conduit as required. i) 20 mm

15

-

-

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ii) Double pole 32 Amp

1

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.i) Group C

14

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

30

-

-

... More
Dismantling of existing wiring, conduit,tube lights, exhaust fans, ceiling fans, switch board and making goods the damage plastering of holes paintind, finishing work complete etc as required.

1

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. i) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire

2

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

2

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.