The PWD has issued a formal invitation for competitive bids for the Public Works Department project, for Supplying, Installation, Testing And Commissioning Of Air Conditioner System In Chief Officer Hamirpur, Distt. Hamirpur (hp) in Una, Himachal Pradesh, with an estimated contract value of Rs. 30,77,935. The bid opening date for this tender is 28-05-2025 and the last date for bid submission is 04-06-2025. Interested bidders for Public Works Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 May 2025
Closing Date4 Jun 2025
Tender Amount₹ 30,77,935 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SITC 3.5 ton air conditioner cassette , invertor type , advanced filter ,E saver mode , quit mode, dual display ,auto clean ,anti bacteria filter jet tool on/off timer slip mode compressor cord less remote complete in all respect or any other equivalent make as per comprising to ISI with AC Invertor hot &cold with as per company standard copper pipe with insulation tape,drain pipe,power cable included power on 230 volt /240 volt +_ 10 % AC supply , two nos free services in one year with in all leads and lift including carrigae of material. Make -Daikin/ O Genral/ Mitsubishi Electric as approved by the Engineer Charge.Warranty on product one year,on PCB five year & on compressor 10 year.

5

191093

-

... More
Installtion charges of Split AC 1.0 TR/1.5 TR/ 1.8 TR unit as required complete in all respect.

19

1415

-

... More
Installtion charges of cassette AC TR with threading rods set of 4 nos with accessories as required complete in all respect.

5

6500

-

... More
Providing and fixing of copper tube for refrigrent size (12.7 mm-6.42mm)with Nitrile tublar insulation including gas charging AC indoor to outdoor for Split AC 1.0 TR/1.5 TR/ 1.8 TR unit as required complete in all respect. Make Godrej/Mehta/Mandev/Rajco/ Nippon/Totaline as approved by Engineer-In-Charge

120

1175

-

... More
Providing and fixing of copper tube for refrigrent size (15.88 mm-9.5 mm) mm with Nitrile tublar insulation including gas charging AC indoor to outdoor for Cassette AC 3.5 TR unit as required complete in all respect. Make Godrej/Mehta/ Mandev/Rajco/Nippon/ Totaline as approved by Engineer-In-Charge

70

1680

-

... More
Providing, laying and fixing of PVC round sheathed 4 core 2.5 sqmm FRLS copper conductor flexible cable for voltage grade up to 1100 volt , as required complete in all respect. Make :-Finolex/Havell/Polycab/KEI/Finolex as approved by Engineer-In-Charge

250

205

-

... More
Supplying and fixing of 25 mm dia of heavy class FRLS PVC conduit having wall thickness 2.0mm along with accessories insurface/recess including painting in case of surface conduit, or cutting the walland making good the same in case of recessed conduit as required.MAKE :- BEC/ DIPLAST/ AKG/ PRECISON FINOLEX/ NIC as approved by Engineer-In-Charge

290

99

-

... More
Providing and fixing of MS Galvanised cable tray of following sizes including accessories as required complete in all respects and as per direction and satisfaction of Engineer in charge. MAKE:- RMCON/ BEC/ LEGRAND/MBM as approved by the Engineer-In-Charge.

-

-

-

... More
100 mm width x 50 mm depth x1.6 mm thickness

90

1120

-

... More
Providing and fixing of M.S power coated frame /stand for erection of out door unit of Split AC 1.0 TR/1.5 TR/ 1.8 TR unit as required complete in all respects and as per direction and satisfaction of Engineer- in charge.

19

885

-

... More
Providing and fixing of M.S power coated frame /stand for erection of out door unit of Cassette AC 3.5 TR unit as required complete in all respects and as per direction and satisfaction of Engineer in charge.

5

1500

-

... More
Supplying and fixing of voltage stabilizer upto 3 KVA having specification Digital display, led indicator & audible alarm, Input voltage range 150-280V, & built in protection ,over voltage ,Under volltage , overload, short circuits high temperature,and low oil levels and also have bypass switchin ,efficiency 98%,torodial core including connections, testing and commissioning as required: Make:- Microtek /V Gaurd /voltas/Blubird as approved by Engineer-In-Charge (Warranty Three year on site)

6

3087

-

... More
Supplying and fixing of voltage stabilizer upto 4 KVA having specification Digital display, led indicator & audible alarm, Input voltage range 130-300V, & built in protection ,over voltage ,Under volltage , overload, short circuits high temperature,and low oil levels and also have bypass switchin ,efficiency 98%,torodial core including connections, testing and commissioning as required: Make:- Microtek /V Gaurd /voltas /bluebird as approved by Engineer-in-charge (Warranty Three year on site)

8

4648

-

... More
Supplying and fixing of voltage stabilizer upto 5 KVA having specification Digital display, led indicator & audible alarm, Input voltage range 130-300V, & built in protection ,over voltage ,Under volltage , overload, short circuits high temperature,and low oil levels and also have bypass switchin ,efficiency 98%,torodial core including connections, testing and commissioning as required: Make:- Microtek/V Gaurd /voltas/ bluebird as approved by Engineer-in-charge (Warranty Three year on site)

10

5222

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit heavy class having wall thickness 2.0 mm as required.Make:-Polycab/KEI/Finolex as approved by Engineer-In-Charge

-

-

-

... More
3 x 2.5 sq. mm

150

151

-

... More
3 x 4 sq. mm

350

220

-

... More
3 x 6 sqmm

10

340

-

... More
3 x 10 sqmm

10

538

-

... More
Supplying and fixing following size/modules,G.I box alongwith modular base & cover for modular switches in recess etc.as requiredMake :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge

-

-

-

... More
1 or 2 Module (75mmX75mm)

48

251

-

... More
Supplying and fixing following Modular type switch/ socket on the existing switch box/ cover including connections etc. as required.Make :-Anchor (Roma classic )/ L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge

-

-

-

... More
6 pin 16/25AMP socket outlet

24

231

-

... More
Supplying and fixing 25 amp single phase motor starter on the existing modular plate & switch box including connections etc. as required.Make :-Anchor (Roma classic ),L&T(Entice),Legrand(Myrius) as approved by Engineer-In-Charge

24

386

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make L&T/ Hager/ABB as approved by Engineer-In -Charge.(Five YEAR WARRANTY)

-

-

-

... More
Single pole

30

236

-

... More
Supplying and erection of 40/50/63 amps, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of pole Double pole in the existing MCB DB complete with connections etc. as required:-Make L&T/ Hager/ABB as approved by Engineer-In -Charge. (Five YEAR WARRANTY)

2

1339

-

... More
Supplying and fixing 63 amp rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and Commissioning etc. as required.-Make L&T SchneiderABB as approved by Engineer-In -Charge.(Five YEAR WARRANTY)

2

3195

-

... More
Supplying and fixing MCB distribution board,12 way Double Door 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) Make L&T/ Hager/ABB as approved by Engineer-in -charge.(Five YEAR WARRANTY)

2

2064

-

... More
Supplying and fixing 63 AMP rating, four pole, (Three phase and neutral), 10 ka , 240 volts, residual current breakerwith over current protection (RCBO), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:- L&T/Legrand/ Hager/ABB as approved by the Engineer-In-Charge.

2

5635

-

... More
Supplying and fixing of MCCB Four pole following rating and breaking capacity with thermal magnet in release complete with connection ,testing and Commissioning etc as required. Make:- L&T/ Legrand/ Hager ABB as approved by Engineer-In-Charge (five year warranty)

-

-

-

... More
125 amp 18 kA

1

7057

-

... More
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation made from (50 mm x 50 mm x 6 mm thick) M.S. angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides & front side hinged, complete with locking arrangement with sufficient No. vertical and horizontal intermediate switchgear supporting members each of M.S. flat 50mmx6mm thick of suitable length duly welded. The cubical pedestal shall have cable entry box at one or two sides and 4 No. legs of 50mmx50mmx6mm thick M.S. angle iron each 60 cm long including, powder coated painting and bonding to the existing earth etc., the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. Removable gland plate and lugs should be provided with each cable entry and also cable support arrangement to be provided inside cable allkey so that cables are neatly arranged. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-The panel should be approved /Tested from the CPRI lab.& should confirmed to IEC-61439 (Part I &II)(Make Power system & control/KSB conforming to IS specifications mentioned etc)

-

-

-

... More
300 Deep

0.5

27837

-

... More
Supplying and fixing copper strip bus-bars suitable for 100 Amp. 415 volts capacity 4 No. each of cross-sectional area (20mmx3mm),in the existing enclosure with all accessories including connections etc. as required.

0.5

9423

-

... More
Supplying and fixing of ammeter inbuilt selector switch CT/PT site programmabe accuracy class1.0;0.5 complete with connection ;testing and commissioning etc Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

1

1524

-

... More
Supplying and fixing of voltmeter inbuilt selector switch CT/PT site programmabe accuracy class1.0;0.5 complete with connection ;testing and commissioning etc as required Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

1

1524

-

... More
S/F indicator set RY &B with 3 Nos Kit kat (LED type) to shown the three indicating in the existing pannel complete etc as required.Make L&T/ Schneider/ ABB as approved by Engineer-In -charge.

1

500

-

... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.

10

160

-

... More
Supplying and fixing of DLP 105x50 mm PVC white adaptable trunking IP 40 on the exiting wall at required height from lower level for power connection, light connection and net working connection including partition chip flexible cover end cap complete in all respect.Make:-Legrand /MK/L&T as approved by Engineer-In-Charge

60

1365

-

... More
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required.Make:-KEI/POLYCAB/ Havells /Finolex as approved by Engineer-In-Charge

-

-

-

... More
16 sqmm (4 core)

25

368

-

... More
25 sqmm (3.5core)

10

426

-

... More
Supplying and fixing of Vertical TPN DB 6 ways DOUBLE DOOR surface/ recess mounting, 7 Segment 415volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, with provision to mount FP-MCB/RCBO incomer and SP/TP MCBs as outgoing (but without MCB ’s and incomer),complete with tinned copper din-bar, wire-set, neutral link, earth bar, detachablegland plate, cable interconnections, including earthing etc. as required:- Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

2

12068

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.