Public Works Department Tender

... More
The PWD has issued a formal invitation for competitive bids for the Public Works Department project, for Construction Of Additional (admin Block) At Govt. High School (girls) Sujanpur Distt. Hamirpur (h.p) (subhead Providing E.i. Therein) in Una, Himachal Pradesh, with an estimated contract value of Rs. 2,17,127. The bid opening date for this tender is 22-05-2025 and the last date for bid submission is 02-06-2025. Interested bidders for Public Works Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date22 May 2025
Closing Date2 Jun 2025
Tender Amount₹ 2,17,127 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
5 (five)/6 (six ) amp Modular switch.

4

87

-

... More
5(five) pin 5 (five)/6 (six) amp socket outlet.

4

135

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3(three) pin 5(five)/6(six) amps modular socket outlet and 5 (five)/6(six) amps modular switch, connection etc. as required.Make :-Anchor (Roma classic )/ L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge

-

-

-

... More
3 (three)Module 100 (hundred) mmX75 (seventy five) mm

3

486

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 (six) pin 5 (five)/6 (six) & 15 (fifteen)/16(sixteen) amps modular socket outlet and 15 (fifteen)/16 (sixteen) amps modular switch, connection etc. as required.Make :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge

2

645

-

... More
Supplying and fixing power unit of 20 (twenty) amp motor stater switch with 16 (sixteen) /20(twenty) amp modular socket including 2(two) module G.I box & cover plate 2 (two) nos including connections etc. as required Make:- Legrand(Myrius)/ L&T(entice)/ Anchor (Roma Clasic ) as approved by Engineer-in -charge .

1

807

-

... More
Supplying and fixing Computer board comprising 3 (three) nos 5 (five) amp modular switches & Sockets , G.I box 2 (two) module for jack box and G.I Box 12 module for 5 (five) amp switchs and 5 (five) amp sockets comprising sheet cover for each 2(two) module metal box , one no computer jack (RJ-45)with shutter including connections etc as required.Make :-Anchor (Roma classic )/L&T (Entice)/ Legrand(Myrius) as approved by Engineer-In-Charge

1

1772

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required. Make:-Plaza/KE/,Finolex & pvc conduit pipe AKG,BEC, Diplast,Poly india as approved by Engineer-In-Charge

-

-

-

... More
2 (two) X 1.5 (one point five) sq. mm + 1(one) X 1.5 (one point five) sq. mm earth wire

40

221

-

... More
2 (two) X 4 (four) sq. mm + 1 (one) X 4(four) sq. mm earth wire

20

364

-

... More
2 (two) X 10 (ten) sq. mm + 1 (one) X 6 (six) sq. mm earth wire

2

666

-

... More
Wiring for light/ power plug with 4 (four)X4 (four) sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0 (two) mm 2 (two) No 4(four) sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge .

4

623

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVCconduit as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge .

-

-

-

... More
3 (three)X1.5 (one point five) Sq.mm

40

116

-

... More
3 (three)X 4 (four) sq. mm

6

263

-

... More
Supplying and fixing of following sizes of PVC conduit Heavy duty minimum thickness 2.0 (two) mm along with accessories insurface/recess including painting in case of surface conduit, or cutting the walland making good the same in case of recessed conduit as required.

15

112

-

... More
Providing, Installation, testing and commissioning of ceiling fan with socket type regulator,including wiring the down rods of standard length (up to 45 cm) with 16 (sixteen)/0.20(point two) mmtwin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required. Make:- Usha (TECHNIX PLUS 3 star)/Orient/Crompton as approved by Engineer-In-Charge(warranty five year)

-

-

-

... More
Ceiling Fan 1200 (one thousand two hundred )mm sweep

11

3420

-

... More
Providing and installation exhaust fan of following sizes in the existing opening,including making the hole to suit the size of the above fan, making good thedamages, connections, testing and commissioning etc. as required (five year warranty). Make:- Usha/Orient/Crompton or its equivalent as approved by Engineer-in-charge(.Warranty five year)

-

-

-

... More
Exhaust Fan, Light duty,300 (three hundred ) mm sweep

3

2149

-

... More
S/F louver and shutter for 300 (three hundred )mm/350 (three hundred fifty) mm on 12mm thick ply board as required complete inal respact

3

600

-

... More
Providing and installation exhaust fan of 300 (three hundred)mm (Plastic body) size in the existing opening,including making the hole to suit the size of the above fan, making good thedamages, connections, testing and commissioning etc. as required(five year warranty). Make:- Usha/Orient/Crompton as approved by Engineer-In-Charge( with five year warranty)

1

2809

-

... More
Supply and fixing of backlit non slim surface/recess led downlighter in 9 (nine) W +/- 1 W in Round Shape with minimum system lumen efficacy of 100 (one hundred) lm/W and minimum system lumens 900 (nine hundred) lumen with Pressure Die cast Aluminium heat sink with and HET diffuser and polycarbonate mounting box P.F.>0.95 (point nine five) ,THD<10 (ten)% ,CCT 5700 (five thousand seven hundred )K/4000 (four thousand )K, CRI 80(eighty), UGR<23 (twenty three),IP20 (twenty) protection.The LED with Useful life of 50000 (fifty thousand ) Hrs at L70 (seventy). The Input voltage range shall be 150 (one hundred fifty)V to 270 (two hundred seventy)V .Fixture have Surge Protection 3 (three)kV .Driver .Make Philips/Wipro/Osram/Jaquar/panasonic or as approved by Engineer-in-Charge.(five year warranty)

4

2037

-

... More
Supply and fixing of backlit non slim surface/recess led downlighter in 18)eighteen) W +/- 1 W in Round Shape with with minimum system lumen efficacy of 100(one hundred) lm/W and minimum system lumens 1200(one thousand two hundred ) lumen with Pressure Die cast Aluminium heat sink with and HET diffuser and polycarbonate mounting box P.F.>0.95(point nine five) ,THD<10(ten)% ,CCT 5700 (five thousand seven hundred)K/4000 (four thousand)K, CRI 80 (eighty), UGR<23 (twenty three),IP20(twenty) protection.The LED with Useful life of 50000(fifty thousand) Hrs at L70(seventy). The Input voltage range shall be 150(one hundred fifty)V to 270(two hundred )V .Fixture have Surge Protection 3 (three) kV .Driver Make Philips/Wipro/Osram/Jaquar/panasonic or as approved by Engineer-in-Charge.(five year warranty)

5

2625

-

... More
Supplying and fixing PVC batten/ angle holder including connection etc. as required.

8

47

-

... More
Providing and installation of following type of LED retrofit Lamp B-22(twenty two) holder base with polycarbomate diffuser and aluminium heat sink including connections, testing and commissioning etc. as required.:Make JAQUAR, wipro,Philips or its equivalent as approved by Engineer-in-Charge

8

167

-

... More
Supplying and fixing Ding Dong bell suitable for single phase, 230(two hundred thirty ) volts, complete as required.

1

297

-

... More
Supply and fixing of Led fixture 4 (four)FTx1(one)FT(Approx) 36(thirty six) W+/- 1(one)W Recess/Surface mounted Mounted with HET diffuser with having minimum system lumen efficacy of 100(hundred)lm/W with CRCA Housing and with P.F.>0.95(point nine five),THD<10(ten)%,CCT 5700 (five thousand seven hundred)K, internal surge protection 2.5(two point five)KV with input voltage range of 150(one hundred fifty )V-270(two hundred seventy)V,CRI 80(eighty).The LED shall be tested with LM(eghty)80-08(eight) standard with Useful life of 50000(fifty thousand ) Hrs at L70(seventy) complete with all accessories, connections, testing and commissioning etc.as required(five year warranty). Make Philips/Wipro/Osram/Jaquar/panasonic or as approved by Engineer-in-Charge.(five year warranty)

5

4490

-

... More
Supply and fixing of IP20(twenty) Led fixture 2(two)FT 10(ten) W+/- 1W with Surface Mounted 2(two) Feet with aluminium housing and Polycarbonate diffuser,minimum system efficacy of 100 (hundred)lm/W with P.F.>0.95 (point nine five) with THD<20(twenty)% ,CCT6500(six thousand five hundred) K,CRI 80(eighty),Surge Protection 2(two) Kv, IP20(twenty).The LED with Useful life of 50000(fifty thousand ) Hrs at L70(seventy). The Input voltage range shall be 150(one hundred fifty)V to 270(two hundred seventy)V. complete with all accessories, connections, testing and commissioning etc.as required. Make Philips/Wipro/Osram/Jaquar/panasonic or as approved by Engineer-in-Charge (five year warranty).

1

565

-

... More
Supply and fixing of IP20 Led fixture 4FT 20 W+/- 1W with Surface Mounted 4 Feet with aluminium housing and Polycarbonate diffuser,minimum system efficacy of 100lm/W with P.F.>0.95 with THD<20% ,CCT6500 K,CRI 80,Surge Protection 2 Kv, IP20.The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 150V to 270V.complete with all accessories, connections, testing and commissioning etc.as required (five year warranty). Make Philips/Wipro/Osram/Jaquar/panasonic or as approved by Engineer-in-Charge.

8

925

-

... More
Supplying and fixing 5(five) amps to 32(thirty two) amps rating, 240(two hundred forty)/415(four hundred fifteen) volts, 10(ten) kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required (five year warranty).Make:-L&T Cat. No. (CM930070000AG ) / legrand/Hagger/ ABB as approved by Engineer-in -charge.

-

-

-

... More
Single pole

11

266

-

... More
Supplying and erection of 40(forty)/50(fifty)/63(sixty three) amps rating, 10(ten) KA breaking capacity, 240(two hundred forty) volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required(five year warranty):-Make :-L&T/Legrand/Hagger / ABB as approved by Engineer-in -charge.

1

1201

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240(two hundred forty) volts, residual current circuit breaker (RCCB), having a sensitivity current 30(thirty) milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required(five year warranty).make:-L&T/Legrand/Hagger / ABB as approved by Engineer-in -charge.

-

-

-

... More
63(sixty three) amp, double pole, (single phase and neutral)

1

3655

-

... More
Supplying and fixing MCB distribution board, 240(two hundred forty) volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator(five year warranty).Make:-L&T Cat. No. (CM930070000AG )/Legrand/Hagger / ABB as approved by Engineer-in -charge.

-

-

-

... More
16(sixteen) way, Double door

1

3027

-

... More
Supplying and fixing true power make advanced earthing system having copper pipe 3(three) meter long 50(fifteen) mm dia with terminal size 50(fifty)x6(six) mm ,internal strip size 25(twentyfive)x3 (three)with 50(fifty) Kg compound including exvation of pit and refiling the same and making earthing pit cover 12 inch dia as required complete in all respect. make :- True power/ Earth plus/Ashloka as per best satisfaction of Engineer-in -charge.

1

14002

-

... More
Providing and fixing 6(six) SWG (4(four) mm dia.) Copper . wire on surface or in recess for loop earthing as required.

15

160

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.