Public Works Department Tender

... More
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Public Works Department - PWD Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date1 Apr 2025
Closing Date8 Apr 2025
Tender Amount₹ 15,51,236 
Notes
Download

Costs

Summary

Supply, Installation, Testing And Commissioning Of 40kva Ups In Trauma Centre First Floor Causality Block, 500 Bedded Hospital At Dr.rpgmc Kangra At Tanda

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply,Erection,Installation and commissioning of Uniearth maintenance free chemical earthing system consisting of environment friendly ground enhancing compound 'G.E.C' 50kg or as required at site having anticorrosive and hygroscopic properties to replace excavated soil. It should consist of Uniearth copper bonded electrodes, as per site conditions and soil resistivity at various depth levels and different terrains. The electrodes should have coating of 250 microns of molecularly bonded pure electrolytic copper(99.9%) in 2 meter length,17.2 mm diameter,terminal joint 200X25X6mm Cu Strip with exothermic welds. The electrode should be duly tested and certified by CPRI for 30kA short time current test for 1 sec rms.

2

18498

36996

... More
S/F of Copper tube with insulation for A.C 1.8/2 TR capacity complete in all respects as required.

5

1150

5750

... More
Armoured cable 25 sq. mm (3.5 core)

20

426

8520

... More
Touch Screen LCD Display and LED indicators

-

-

-

... More
Overload Capacity: A) 10 minutes at a load representing 125% , B) 60 second at a load representing 150%

-

-

-

... More
UPS should has feature of common battery bank up to at least 2 units.

-

-

-

... More
Make : - KEI/Plaza/Anchor

-

-

-

... More
UPS overall Efficiency : upto 95% ( AC to AC i.e Online Mode) and 98% ( Eco Mode ) without Isolation transformer

-

-

-

... More
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required.

-

-

-

... More
63 Amps

1

530

530

... More
Make : - KEI/Plaza/Anchor

-

-

-

... More
100 Amp. -16 KA

2

6874

13748

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required

-

-

-

... More
Makes:- L&T/Legrand/Schneider.

-

-

-

... More
Interface ports : USB/ RS 232 & optional SNMP .

-

-

-

... More
Battery Make : Quanta / Exide/Panasonic

-

-

-

... More
S/F of Drain pipe of size 1" Dia (25 mm) complete with elbows tees, socket etc. of superior quality as per satisfaction of Engineer-in-charge.

12

195

2340

... More
ISO 9001 & 14001,45001 certified OEM ,Safety Standard: IEC62040-1, EMC: IEC62040-2, Performance IEC62040-3 , along with CE/UE certification. Product should be ROHS & PEP certified And IP20 Protection ,Quoted model should be tested by SAMEER/ERTL/NTH or any Govt. approved NABL Accredited Lab. Bidder to submit the type test report from any Govt. LAB /NABL accredited LAB in supporting to above technical parameters.

-

-

-

... More
Supplying, installation, testing and commissioning of 40 KVA/40KW UPS system 3 phase input and 3 phase output, with Full Digital Signal Processing (DSP )Technologies, inbuilt digital LCD Touch Screen display, Based on IGBT based Rectifier and IGBT based Inverter technology, online double conversion, fully microprocessor controlled UPS system with input voltage range from 320V to 476V ,3phase,50Hz, 4 wire, AC supply and output of selectable 380V/400V/415V, 3phase, 50Hz ,UPS should be with inbuilt Galvanic isolation transformer of same OEM Make at input side with static and manual maintenance by-pass complete with 12V SMF battery bank (30 minutes backup with min VAH of battery bank as 36000VAH) . complete with all accessories including battery racks, interlinks, cabling including all petty material required to complete the job upto entire satisfaction of the Engineer-in-charge. UPS should be with standard Surge protection feature (Inbuilt TVSS), EPO feature (Emergency power off), cold start feature with inbuilt dust filters and input phase sequence protection as default. UPS should have overall efficiency should be more or equal to 95%. UPS should have overload capacity of 125% of full load for minimum 10 minutes time & 150% for 1 minute. UPS should have feature of common battery bank up to at least 2 units and Flexibility in no. of Batteries /variable VDC ranges should be there (at least 6-8 batteries flexibility should be there). UPS should have warranty of 60 months and Battery bank having warranty period of 24 months from date of commissioning. UPS OEM should be ISO 9001, 45001 & 14001 certifies with following Safety & Safety: Certifications & Standard: CE/UE IEC62040-1, EMC: IEC62040-2, Performance IEC62040-3 , Product should be ROHS,REACH & PEP certified. Quoted model should be tested by SAMEER/ERTL/NTH or any Govt. approved NABL Accredited Lab. Bidder to submit the type test report from any Govt. LAB /NABL accredited LAB in supporting to above technical parameters. OEM should have 3-4 own /ASP based service centers in the state for better & timely service support, need to share at least 2 engineers contact details with service center address details in the region of installation and OEM Turnover should not be less than 500 Crores/year in last 3 financial years with profitability. 10 years presence of OEM in Govt. project segment And Quoted product should be available on OEM Website with as per asked technical compliance.

1

1165300

1165300

... More
Makes:- L&T/Legrand/Schneider.

-

-

-

... More
Input power factor (PF) greater than or equal to 0.99

-

-

-

... More
Supplying and fixing Computer board comprising 3 nos 5 amp modular switches & Sockets and G.I Box 12 module for 5 amp switchs and 5 amp sockets comprising frame and cover plate for each 2 module and 12 module metal box including connections etc as required.

1

1191

1191

... More
Makes:- L&T/Legrand/Schneider.

-

-

-

... More
Copper tape 20 mm X 3 mm thick

60

666

39960

... More
Makes:- L&T/Legrand/Schneider.

-

-

-

... More
Make:- APC-Schneider /Emerson -Vertiv /Legrand-Numeric only for UPS & Exide, Quanta & Panasonic for SMF Batteries.

-

-

-

... More
Supplying and Fixing wall mounting voltage stabilizer of following rating with output 240 volts with voltage regulation range from 130 volt to 280 volts and auto cut off beyond this range and time delay operation for the surges and fluctuations suitable for 1.5/2 TR capacity split type Air-Conditioner including making connections etc. as required complete in all respects.

-

-

-

... More
Approved Make : APC- Schneider / Vertiv -Emerson/ Legrand-Numeric Only for UPS & Exide, Quanta & Panasonic for SMF Batteries. .

-

-

-

... More
Makes:- L&T/Legrand/Schneider.

-

-

-

... More
Output Power Capacity in watts (KW) 40KVA / 40KW

-

-

-

... More
Makes:- L&T/Legrand/Schneider.

-

-

-

... More
Battery Bank : UPS unit shall be equipped with its independent battery bank of the following:

-

-

-

... More
Make:- (Model Daikin FTHT50 3* HOT & COLD INVERTER 1.5 TR / VOLTAS/Blue Star

-

-

-

... More
SERVICE & Support : OEM should have 3-4 own /ASP based registerted service centers in the state for better & timely service support, need to share at least 2 engineers contact details with service center address details in the region of installation and OEM Turnover should not be less than 500 Crores/year in last 3 financial years with profitability. 10 years presence of OEM in Govt. project segment And Quoted product should be available on OEM Website with as per asked technical specifications

-

-

-

... More
Emergency Power Off (EPO) Should be available as standard

-

-

-

... More
6 way, Double door

1

1566

1566

... More
63 Amp

1

3104

3104

... More
OUTPUT FEATURE :

-

-

-

... More
Automatic Voltage Stabilizer 4 KVA

1

6500

6500

... More
Supplying and fixing suitable size GI box with modular plate and cover in FRLS on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

1

621

621

... More
P/F of M.S out door heavy duty stand powder coated suitable to hang 1.5 TR split A.C with Six Nos. Anchor bolts as required complete in all respects and as per direction of Engineer-in-charge.

1

950

950

... More
Supplying and fixing of Segregated tripple pole and neutral 8 ways surface/ recess mounting, 7 Segment 415volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, with provision to mount MCCB incomer, DP MCB/RCCB sub-incomer in each phase and SP MCBs as outgoing (but without MCB ’s and incomer), complete with tinned copper din-bar, wire-set, neutral link, earth bar, detachable gland plate, cable interconnections, including earthing etc. as required:-

-

-

-

... More
AC Unit 1.5 TR Capacity

1

57170

57170

... More
Total Harmonic Current Distortion (THDI ) should be less than 3 % at full rated load

-

-

-

... More
Alarms : Audible Alarm required for Mains failure, Low Battery, Inverter Trip, Over Temperature, Over Load

-

-

-

... More
INPUT FEATURE :

-

-

-

... More
Noise Level :Less than 65 dBA

-

-

-

... More
Makes:- L&T/Legrand/Schneider.

-

-

-

... More
Other Features

-

-

-

... More
Nominal Frequency 50 Hz

-

-

-

... More
Supplying , installation, Testing and Commissioning of Split Type Air Conditioner 1.5 TR 3 Star inveryer SPLIT AIR CONDITIONING (Hot & Cold) confirming to I.S.I.-1391 Part-1992 with ammendement No. 1 (expect power consumptions norms) fitted with Hermitically shielded Air Conditioner with installation testing & commsiisoning etc as required complete in all respects.

-

-

-

... More
VRLA type, mounted on a rack with a design life of 3 yrs as per OEM , Sealed Maintenance Free - Lead Acid Battery with suspended Electrolyte (Leak Proof)The battery shall be sized to ensure continuity in the supply to the inverter for 30 minutes for a power rating of 40KVA at 0.8PF & 1.7 ECV.

-

-

-

... More
Battery Type : DC Voltage Bus with Flexibility of at least 6-8 no. of Batteries , Min. 30 Mins Backup , 12V Batteries will be provided by firm Minimum required VAH per UPS =36000 VAH.

-

-

-

... More
Operating Temperature : 40 degree C

-

-

-

... More
Bypass : UPS Should Be built in Manual and Maintenance Bypass

-

-

-

... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Make : - KEI/Plaza/Anchor

-

-

-

... More
The UPS should have following specification.

-

-

-

... More
Protection requried :TVSS inbuilt ,over volatage,short circuit ,overload at UPS O/p and Under Voltage at battery terminal,input phase sequence protection feature,with dust filters and inbuilt TVSS feature. for surge protection.

-

-

-

... More
Make : - KEI/Plaza/Anchor

-

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required

-

-

-

... More
Make : - KEI/Plaza/Anchor

-

-

-

... More
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required.

-

-

-

... More
Total Harmonic Distortion : 2% for linear load & 5% for 100% non-linear load

-

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required

-

-

-

... More
Battery Rack & Links - Racks Suitable for Mounting the All Batteries each Sheet Metal Type along with interconnection cables and 5/7 meter wire from UPS to battery bank.

-

-

-

... More
Input Voltage window 320 VAC - 480 VAC 3 Phase

-

-

-

... More
Warranty Terms : Five Years on UPS & 2 years on Batteries with onsite service Support

-

-

-

... More
Output Voltage - 380 / 400 /415 Volts rms, adjustable via the user interface.

-

-

-

... More
TPN DB 8 Way

1

14537

14537

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

20

311

6220

... More
63 Amp TP MCB

4

2268

9072

... More
Providing and fixing Copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

20

198

3960

... More
Providing and fixing Copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For Vertical run)

-

-

-

... More
Copper tape 20 mm X 3 mm thick

80

616

49280

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor 2.5 Sq. mm 3 Core cable in the existing surface/recessed steel/PVC conduit as required.

10

280

2800

... More
Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

4

239

956

... More
Output Frequency range 50/60 HZ.

-

-

-

... More
Makes:- L&T/Legrand/Schneider.

-

-

-

... More
Parallel option : Parallel option upto 4 Units should be available

-

-

-

... More
Output Power Factor should be unity.

-

-

-

... More
Makes :- V-Guard/Godrej/Microtek

-

-

-

... More
Input Frequency window 45-55 Hz .

-

-

-

... More
4 X 10 sq. mm + 2 X 6 sq. mm earth wire

90

1045

94050

... More
Safty Standard & Certifications and Test reports

-

-

-

... More
Makes:- L&T/Legrand/Schneider.

-

-

-

... More
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.

-

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Armoured Cable 6 Sq.mm. (4 core)

15

541

8115

... More
Providing and fixing 4mm Dia 8 SWG Copper wire on Surface or in recess for Loop earthing as required complete in all respects.

100

180

18000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.