Institute Of Himalayan Bioresource Technology Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Institute Of Himalayan Bioresource Technology - IHBT Tender
Electrical and Electronics
Eprocure
Opening Date7 Apr 2022
Closing Date18 Apr 2022
Tender Amount₹ 8,06,656
Costs
EMD
₹ 16,200Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_CSIR_112299_1Bid Award Id
ViewTender No
5-263/Ws/22Tender Authority
Institute Of Himalayan Bioresource Technology ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT and Contract Document for the work of Upgradation and Shifting of DB at NPP Lab Floriculture lab Administrative block with submain wiring and SITC of LT Cables therein
Upgradation and Shifting of DB at NPP Lab, Floriculture lab, Administrative block with submain wiring and SITC of LT Cables therein.
BOQ Items
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed ISI marked steel conduit as required. i) 4x4 sqmm + 2x4 sqmm earth wire(FRLS Copper wire make : KEI/ Anchor/ Finolex/Polycab)
190
-
-
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed ISI marked steel conduit as required. i) 4x10 sqmm + 2x6 sqmm earth wire(FRLS Copper wire make : KEI/ Anchor/ Finolex/Polycab)
25
-
-
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed ISI marked steel conduit as required. i) 4x16 sqmm + 2x6 sqmm earth wire(FRLS Copper wire make : KEI/ Anchor/ Finolex/Polycab)
20
-
-
Supplying and drawing following size of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed steel/PVC conduit as required. i)3x2.5sq.mm(FRLS Copper wire make : KEI/ Anchor/ Finolex/Polycab)
55
-
-
Supplying and drawing following size of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed steel/PVC conduit as required. i) 6 x2.5sq.mm(FRLS Copper wire make : KEI/ Anchor/ Finolex/Polycab)
5
-
-
Supplying and drawing following size of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed steel/PVC conduit as required. i) 3 x4sq.mm(FRLS Copper wire make : KEI/ Anchor/ Finolex/Polycab)
190
-
-
Supplying and drawing following size of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed steel/PVC conduit as required. i) 6 x4sq.mm(FRLS Copper wire make : KEI/ Anchor/ Finolex/Polycab)
64
-
-
Supplying & drawing following pair 0.5 mm dia FRLS PVC insulated anneaaled copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required. i) 2 Pair
20
-
-
Supplying & fixing of following sizes of ISI marked steel conduit alongwith accessories in surface/ recess including painting in case of surface conduit ,or cutting the wall and making good the same in case of recessed conduit as required. i) 25 mm
40
-
-
Supplying & fixing of following sizes of ISI medium class PVC conduit alongwith accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. i) 25 mm
20
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. i) 5/6A Switch
105
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. i) 3 pin 5/6 A socket outlet
12
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. i) Telephone socket outlet
1
-
-
Supplying & fixing 2 Module Stepped type Electronic Fan Regulator on existing Modular Plate Switch box including connection but excluding modular plate extra as required. (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
29
-
-
Supplying & fixing modular blanking plate on the existing modular plate switch box excluding modular plate as required.
20
-
-
Supplying & fixing following size/ modules, GI/ PVC box alongwith modular base & cover plate for modular switchs in recess etc as required. i) 1 or 2 Module (75 mm x 75 mm)
1
-
-
Supplying & fixing following size/ modules, GI/ PVC box alongwith modular base & cover plate for modular switchs in recess etc as required. i) 8 Module (125 mm x 125 mm)
6
-
-
Supplying & fixing following size/ modules, GI/ PVC box alongwith modular base & cover plate for modular switchs in recess etc as required. i) 12 Module (200 mm x 200 mm)
10
-
-
Supplying & fixing suitable size GI/ PVC box with modular plate in front on surface or in recess, including providing & fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
52
-
-
Supplying and fixing 3 pin, 5 A ceiling rose on the existing juction box/wooden block including connection etc. as required.
20
-
-
Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed steel/ PVC conduit as required. (Make: D Link/ Digilink) i) 1 Run of Cable
20
-
-
Supplying & fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No. 3 Pin 5/6 Amp. Modular socket outlet and 2 Nos. 5/6 Amp. Modular switch, connections etc. as required. ( FOR LIGHT PLUGS TO BE USED IN NON RESIDENTIAL BUILDING). (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
44
-
-
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreadders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. (Make:Havells/L&T/Indo-Asian). i) 125A, 16KA, TPMCCB
6
-
-
Supplying and fixing following way, horizontal type three pole and neutral surface/ recess mounting, ,415 V, MCB Distribution Board, complete with tinned copper bus bar, neutral bus bar, interconnection, powder painted including earthing etc. as required. (But without MCB/ RCCB/isolator) as required. (Make: Havells/L&T/Indo-Asian). i) 8 way (4 + 24), Double Door
1
-
-
Supplying and fixing following way, surface/ recess mounting, vertical type,415 V, TPN MCB Distribution Board, sheet steel, dust protected, powder painted, inclusive of 200 A, tinned copper bus bar, neutral bus bar, earth bar, din bar for mounting MCBs and having provision for mounting 125A, 16KA,TPMCCB as in comer (But without MCBs and incomer) as required. (Make:Havells/L&T/Indo-Asian). i) 8 way (4 + 24), Double Door
1
-
-
Supplying and fixing following way, surface/ recess mounting, vertical type,415 V, TPN MCB Distribution Board, sheet steel, dust protected, powder painted, inclusive of 200 A, tinned copper bus bar, neutral bus bar, earth bar, din bar for mounting MCBs (But without MCBs and incomer) as required. (Make: Havells/L&T/Indo-Asian). i) 12 way (4 + 36), Double Door
5
-
-
Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Havells/L&T/Indo-Asian). i) Single pole
220
-
-
Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Havells/L&T/Indo-Asian ). i) Triple pole
6
-
-
Supplying and fixing TP Sheet steel enclosure on surface/recess along with 16/25/32 A 415 V ''C'' curve TP MCB completed with connections,testing and commissioning etc. as required.
4
-
-
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
6
-
-
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia GI pipe from earth electrode including connection with copper thimble excavation and refilling as required.
18
-
-
Providing and fixing 4.00 mm dia. Copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required.
40
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE Power cable of 1.1 KV grade of following size ion the existing RCC/HUME/METAL PIPE/HDPE pipe as required. I) Above 35 sq.mm and upto 95 sq.mm
325
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE Power cable of 1.1 KV grade of following size ion the existing masonary open duct as required. I) upto 35 sq.mm
20
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE Power cable of 1.1 KV grade of following size ion the existing masonary open duct as required. I) Above 35 sq.mm and upto 95 sq.mm
65
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. i) Up to 35sq.mm(Clamped with 1mm thick saddle)
45
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. i)Above 35 sq.mm and up to 95sq.mm(Clamped with 25x3mm MS CLAMP)
40
-
-
Suppying & laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, coupler etc. conforming to IS 14930, Part II complete witj fitting and cutting cutting, jointing etc. in the existing trench, complete as required. i) 63 mm Dia ( OD - 63MM mm & ID 51 mm nominal)
65
-
-
Supplying & laying of following size DWC HDPE pipe ISI marked along with aa aacessories like socket, bend, couplers etc. confirming to IS 14930, Patr II complete with fitting and cutting, jointing etc. direct in ground (75cm below ground lavel) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. i) 63 mm dia ( OD 63 mm & ID 51 mm nominal)
325
-
-
Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ Havells/ KEI ) i) 3.5 core 25 sqmm
50
-
-
Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ Havells/ KEI ) i) 3.5 core 35 sqmm
75
-
-
Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ Havells/ KEI ) i) 3.5 core 50 sqmm
135
-
-
Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ Havells/ KEI ) i) 3.5 core 70 sqmm
185
-
-
SITC of RJ 45 computer Socket Cat 6 (I/O Box complete kit). (Make : D Link/ Digilink).
1
-
-
Supplying & fixing Single Phase, 230 volts, 1400 RPM, plastic body exhaust fan / ventilating fan , size 250 mm sweep complete as required. (Make: Bajaj/ Havells/ Crompton)
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements