Himachal Pradesh Irrigation And Public Health Department Tender

... More
The HPIPH has issued a formal invitation for competitive bids for the Himachal Pradesh Irrigation And Public Health Department project, for Providing Lwss To P-c Habitation Of C-v Badhala Bag Bein Etc In G-p Panar Tehsil Nahan Distt Sirmour Hp in Sirmaur, Himachal Pradesh, with an estimated contract value of Rs. 2,02,500. The bid opening date for this tender is 27-02-2019 and the last date for bid submission is 07-03-2019. Interested bidders for Himachal Pradesh Irrigation And Public Health Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender

Opening Date27 Feb 2019
Closing Date7 Mar 2019
Tender Amount₹ 2,02,500 
Notes
Download

Costs

Summary

Providing Lwss To P-c Habitation Of C-v Badhala Bag Bein Etc In G-p Panar Tehsil Nahan Distt Sirmour Hp

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/ recommendations.

2

-

-

... More
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side.

1

-

-

... More
Supply & fixing at site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.

2

-

-

... More
ACB/MCB/Oil circuit breaker of suitable capacity of Kilburn/L &T/MEI/GEC/Standard make on incomming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with initial oil filling whenever required & neutral linked under voltage release.

1

-

-

... More
Supply and fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader /Pelicon / KSB make of suitable size Cast Steel double flanged swing check type reflux valve conforming to API standards with upto date ammendments for R/main as mentioned in item No.1 (c) for withstanding nominal seat pressure as per item No.1(a)+ surge pressure . The size of reflux valve shall be equal to size of rising main of the same shall be provided with suitable bye pass arrangement (Class ASA-300.)

1

-

-

... More
Supply & fixing at site of suitable direct on line/oil immersed star delta /ATS/stator rotor starter of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling . (Note:- Star - delta - starter upto 37.5 KW , ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50 KW.)

2

-

-

... More
Voltmeter AC supply,100 mm dia circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS 4064-1978 with up to date ammendments.

1

-

-

... More
ICTP switches with HRC fuses of Kilburn/Larsen & Tubro/Standard/Siemen/Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.

2

-

-

... More
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump G.I pipe (H) with flange table -17. (NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer incharge).

1

-

-

... More
Supply, erection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single,/Multistages centrifugal pumps of standarad make such as KSB/ Mather & Platt/ Jyoti /Kirloskar/ Beaconweir /BS & BE conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handle clear water having characterstics as mentioned in Item 1 (a) with impelleres,casing ring, priming funnels & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel /Mild steel to BHEL /Kirlokar/ NGEF/ Crompton / Siemen/Jyoti /GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below including the cost of all accessories in all leads and lifts and carriage of material at site as per direction of the Engineer Incharge. (Total Head-248.5 mtrs., Capacity-1.78 LPS, Dia of R/Main-50mm)

2

-

-

... More
Supply & fixing at site of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).

2

-

-

... More
Change over Switch of reputed make & suitable capacity

1

-

-

... More
P/L & fixing of double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.

1

-

-

... More
P/L & fixing at site of work of suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.

1

-

-

... More
Providing & fixing at site M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories incljuding the cost of P/F these accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.

1

-

-

... More
Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments

1

-

-

... More
P/L & fixing at site of work of suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.

1

-

-

... More
Supply and fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of suitable size cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump (Class ASA-300).

2

-

-

... More
Busbar chamber having three copper bars of suitable rating for full length equal to width of board of three live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.

1

-

-

... More
Three phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.

2

-

-

... More
Ammeter AC supply,100 mm dia circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS 1248-(P-II)1983 latest with up to date ammendments.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.