Himachal Pradesh Irrigation And Public Health Department Tender
... More
The HPIPH has issued a formal invitation for competitive bids for the Himachal Pradesh Irrigation And Public Health Department project, for Improvement Of Distribution System And Replacement Of Old Damaged Rusted Pipe Various Water Supply Scheme Under Ghumarwin Constituency In Ghumarwin in Bilaspur Hp, Himachal Pradesh, with an estimated contract value of Rs. 12,00,000. The bid opening date for this tender is 08-01-2025 and the last date for bid submission is 14-01-2025. Interested bidders for Himachal Pradesh Irrigation And Public Health Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender
Machinery and Tools
Eprocure
Opening Date8 Jan 2025
Closing DateCancelled
Tender Amount₹ 12,00,000
Costs
EMD
₹ 24,000Document Cost
₹ 400Tender Fee
Refer Documents
Summary
Improvement Of Distribution System And Replacement Of Old Damaged Rusted Pipe Various Water Supply Scheme Under Ghumarwin Constituency In Ghumarwin
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_HPIPH_97661_1Tender No
GMR-BLP02-737(9848-90)BhalluTender Authority
Himachal Pradesh Irrigation And Public Health Department ViewPurchaser Address
-Website
http://http://hpiph.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Selector Switch for Auto and Manual Operation
-
-
-
... More
Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges.
-
-
-
... More
Motor side: suitable capacity Min length = 20 mtrs.
-
-
-
... More
Supply side: suitable capacity Min. length =10 mtrs.
-
-
-
... More
Shielded Data Cable for Communication of Level Sensor with PLC
-
-
-
... More
Power and Control Wiring and Busbar
-
-
-
... More
Independent Control Panel with Switch Fuse Unit and Fuses of Suitable Amperage to eliminate the KItKat fuses of HPSEB Make: Siemens/Schnieder/L&T/reputed approved make
-
-
-
... More
HMI (Human Machine Interface) 7" display for Monitoring and Controlling of Centrifugal pumps Make: Bechoff Automation/Roackwell/ reputed approved make
-
-
-
... More
Power quality monitoring & controlling relay with Control Contactor to safeguard the Electronic & Electric elements
-
-
-
... More
Supply Installation, Testing and Commissioning of PLC Control Panel with appropriate digital and analog inputs and outputs to give automatic command to Star Delta Starter Panel/ Energy Saving Variable Frequency Starter Panel Make Siemens/Allen Bredley/reputed approved make
-
-
-
... More
Input Choke of required HP for Energy saving variable frequency Starter which should be installed at the input of Energy saving variable frequency starter, so that there should be proper protection in case of any voltage surge and distortions.
-
-
-
... More
Control MCB for Automation System
-
-
-
... More
Cloud GateWay for Data Clouding to Server
-
-
-
... More
Note:-If any item is missing in pannel board of pump/PLC/automation of submersible and centrifugal pump requored to make the system functional will have to be executed in the above cost and two years maintanence cost is included in the cost of pannel board of pump and automation.
-
-
-
... More
Providing & Installation of horizontal spindle horizontal split casing / end suctions (back pull out arrangement ) single /double/multistage centrifugal pump or combination of pump in series of RKB/KSB/Kirloskar and mather and Platt make as per BIS 1520-1980 with up to date amendments, read with IS:9137-1978 or latest edition suitable for lifting clear water . The pump should be fitted with bronze impellers, priming funnels , casing rings, shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on MS/ Cast steel base plate ( base plate to be provided from the manufacturer,s of the pumping unit only) to squirrel cage drip proof induction motor of standard make such as Kirloskar/Crompton/ KSB confirming to BIS 9238-1979 latest with up to date amendments and suitable for operation on 400 (+/-) 10% volts, 50 cycles / second, three phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of + 10% and - 15% of the duty point head. The motor should be as per IS 325-1978 with up to date amendments.The pump set should suitable for operation on data given below:- ( 2 No. Pumping set i.e. 2x 125= 250 HP )
250
-
-
... More
The GMS tube confirming to IS :- 1239-1979 part-I Medium class flanged with MS flanges of table 5 in suction pipe and heavy class flanged with MS flanges of table 17 in delivery side and common header.
-
-
-
... More
Electronic relay card 8 channel
-
-
-
... More
Providing and fixing double loop earthing with copper plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm. G.I strips and G.I wire as per IS: 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
-
-
-
... More
Cloud Space for data storage at cloud/server
-
-
-
... More
LED Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.
-
-
-
... More
Providing and instalation of VFD Starter for centrifugal pump with SCADA based Automation
-
-
-
... More
Installation, Commissioning and Software Development
-
-
-
... More
Supply of Mobile App (Android/IOS) with User ID and Password to monitor and control the pumping operation from Mobile for 3 users. Make: JSV Approved
-
-
-
... More
Energy Saving Variable Frequency Starter of 125 HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to monitor & control the frequecy of pumps through out the operation and to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temperature upto 50 Degrees celcius without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: JSV Approved
-
-
-
... More
Control Transformer Make: JSV Approved
-
-
-
... More
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
-
-
-
... More
Installation, Commissioning and Software Development
-
-
-
... More
Discharge:-11.36 LPS per set, Total dynamic head :- 354.18 metre, Suction Lift:- postive, Dia of Rising Main:- 125 mm , Length of Rising Main:- 3300 Rmt, Pumping Hours:- 8 hours, Coupling and base plate :- 1 sets, Turbidity :- less than 50 NTU, Temprature 20 degree to 45 degree centigrade.
-
-
-
... More
SCADA software to be installed in Laptop/PC to remotely monitor and control the operation of pumps and also to analysis the pump start and stop history logging, fault status, fault history, Power Quality Parameters like PF, Current, Voltage, KWH, THD etc Make JSV Approved
-
-
-
... More
Common header 125 mm dia M.C Minimum length = 10 metre
-
-
-
... More
Level Sensor to indicate the water level of tank remotely
-
-
-
... More
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc. with RS 485 communication Make:- L&T/Conserve/Schnieder
-
-
-
... More
Suction pipe 150 mm dia M.C Minimum length= 5 metre
-
-
-
... More
Supply , Installation, Testing and Commissioning of Energy Saving Variable Frequency Starter Panel for centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. pumps (1 working & 1 stand by) each of the rating 125 HP . Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators, Power Quality Monitoring & Controlling Relay at the Incomer Feeder, Should be fitted with Surge Suppressor Device suiatble to protect against class-1 & 2 surges.
Make: Aarmation Electric/Tricolite/L S Controls/Adlec
-
-
-
... More
SMPS 4.5 Amps to energise PLC system
-
-
-
... More
Providing and fixing double flanged GMS piping network for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as rappers, flanges, rubber gaskets minimum 3 mm in thickness as per IS 2712-1979, nuts and bolts as per IS:1364-1983, bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as per drawing up to 5 metre away from the outer wall of pump houses. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated.The size of various components are as under:-
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements