Bhakra Beas Management Board Tender
... More
The BBMB has issued a formal invitation for competitive bids for the Bhakra Beas Management Board project, for Emergency Flood Warning System At Dam Site Pandoh Engineering And Designing Erection Testing And Commissioning Of Alert Information And Direct System At Pandoh Dam in Mandi, Himachal Pradesh, with an estimated contract value of Rs. 96,01,186. The bid opening date for this tender is 23-04-2025 and the last date for bid submission is 24-04-2025. Interested bidders for Bhakra Beas Management Board tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Bhakra Beas Management Board - BBMB Tender
Opening Date23 Apr 2025
Closing DateCancelled
Tender Amount₹ 96,01,186
Costs
EMD
₹ 1,92,100Document Cost
₹ 2,360Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_BBMB_231976_1Bid Award Id
ViewTender No
NIT-01-2024-25-PandohDamTender Authority
Bhakra Beas Management Board ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Notice Inviting Tender regarding Emergency Flood Warning System at Dam Site Pandoh Engineering and Designing Erection Testing and Commissioning of Alert information and direct system at Pandoh Dam
BOQ Items
... More
For Supply ,Testing, Designing, Erection and commissioning of Local station for Alert, Information and Direct system comprising of the following hardware/software: • Panel/Housing with power supply module • Radio Router/Modem.• Dual SIM 3G/4G communication Router • Intelligent Remote Terminal Unit (RTU) or Programmable Logic Controller etc.• Pre-Programmed Audio Amplifier with Bi- directional speakers • Starter with feedback arrangement for siren.Strobe Light • Mounting hardware and cable connectors etc.• Set of applications and system software. Panels for Mounting Hardware: • The panel should be duly wired and sufficiently spaced to accommodate all the equipment. The panel should have IP65 protection and made of SS-304 sheet metal. The earthing bolts should be available at both sides. The enclosure should have double door and a canopy with proper weather protection. The panel should have pad lock arrangement and pole mounting arrangement. The system should be capable to run on both solar operated 24 V DC & 230 V AC Power and Backup: All the stations equipment (i.e. Hooters, PA system, strobe lights, PLCs etc.) must be primarily powered and activated by solar panel. The status of Power Supply must be available in the Control Room. Siren System:Must have provision of Pre recorded /programmed audio messages in multiple languages. (English/Hindi/ Punjabi. Strobe Light: Light Color : Red Operating Voltage: 24/12V DC Flash pattern :Double Flash, Mounting : Permanent Mount. Flashes per minute -60 Flashes Light output -500 Candela per second.Rated current 0.9 Amperes Strobe Light should be installed in Local Stations in a manner that it is visible from at least 500 m @ ATF= 74. The Controller should be designed to have Communication for wireless mode like GSM, as well as radio-frequency module between control room and All Site Location including Transmitter, Receiver & Repeaters and associated software, and shall be designed to have communication compatibility such as GPRS, Radio, Satellite or Wired mode like Internet, Broadband to transmit data and receive commands remotely. Standards and certifications 1. Standards CSA C22.2 No 142, UL 2. EN/IEC 61131.2:2007 3. Product Certifications shall be from CSA, RCM,IASCE10, CULUS 4. IEC/EN 611312 Ed 3, completed by IEC61010-2, 201 5. OCSA-E 1131.2 6. UL 61010.2. 201 7. Low Voltage: 2006/95/EC 8. Electromagnetic compatibility: 2023/108/EC Design Features of PLC: 1. Full Ethernet architectures with access to data from anywhere: immediate insight into the process. 2. Ethernet transparency allows access to data from everywhere. 3. Built to withstand extreme temperatures (-10°C to +60°C). 4. Robust and well-designed controller with a long-life cycle. 5. Communication Ports 1 no Ethernet port, (MODBUSTCP/IP support).6. Inputs / Outputs Controller should have built-in ON board minimum IOs 8 digital inputs, 8 digital outputs and 2 Analog Inputs (0 to 10volt) Inbuilt RTC support. 7. Memory Controller shall have minimum 2MB internal RAM memory, 2MB programs constants. 8. Controller shall be battery less system type. 9. Extensive and simple to use management tool for firmware and program management in large scale PLC applications. 10. Simple: compact size, all in one, which reduces Installation time. 11. Reliable and extremely accurate to accommodate sun positioning algorithms. 12. Basic Software package should also be from the same source as that of PLC/RTU 13. The software should be Mobile app and web based controlling system, the system can be expand to accommodate changing needs. 14. Total 50,000 Nos Text Message Service for Alert Systems for local resident. 15. All the equipment’s software and hardware should cover minimum 03 years of onsite warranty. Manufacturer. Preferred Makes for PLC System/RTU: Siemens/ ABB/Rockwell/Schneidr Cyber security on 1. Access to the controller shall be password protected.Additionally, only selected devices are allowed to connect to controller. 2. Memory protection mode is available via physical inputs or software configuration. The application and user data are protected in this mode.3. Run/Stop protection mode is available via physical Programming Software for RTU:The control logic shall be programmed using intuitive flow chart programming. The Programming software shall have following features 1. Logic building 2. Debugging tools such as break nodes, break points, watch nodes etc. 3. It shall be possible to define watch variables and modify them. 4. Should support built in simulator for off line testing of logic. 5. It shall be possible to see the effect of logic execution using mimic generated. 6. Logic shall be divided into emergency, sequence and interlocks. 7. It shall have a library of timers, counters and PID function blocks.
6
-
-
... More
For Supply, Testing, Designing, Erection and commissioning of Interface system for Radio and 3G/4G link on wireless communication through dual SIM and associated software at control room All feedbacks A suitable interface/communication system of reputed make should be installed in the Local Station with the capability of operating over 3G/4G Link through Dual SIM and should be accordingly interfaced with main Control Room SCADA.
1
-
-
... More
For Supply, Testing, Designing, Erection and commissioning of Cable and required mounting accessories Power Cables and Accessories: All required power cables and accessories to make the system functional will be supplied by the vendor.Cables should comply with IS-694, IS-3961, IS8130 and IS-5831 MAKE: Polycab / Finolex / Universal / Havells.
1
-
-
... More
For Supply, Testing, Designing, Erection and commissioning of Dual SIM 3G/4G VPN Router Support TCP server,Design with standard TCP/IP protocol stack Support APN/VPDNO Support Dual SIM/UIM card Support VPN client Cellular Specification GSM/GPRS/EDGE • CDMAD TX Power 32 dbm RX sensitivity - 93.30 dbm Hardware System CPU Industrial 32bits CPU FLASH 16MB (Extendable to 64MB) DDR2 128MB (Extendable to 256MB) . Interface type, Ethernet-1 No.
6
-
-
... More
For Supply, Testing, Designing, Erection and commissioning of Autonomy of the System .The system should have Solar Panels of Sufficient Rating to be autonomous for minimum three days i.e. the system should have sufficient storage capacity in the shape of batteries charge controller and other accessories required for successful operation of the system in case of non- availability of sunlight and the system operate for minimum five times in a day. Solar panel with 24/12V DC output with required W/VA capacity to be decided by the vendor. The System should be capable of bearing the load of the Local Control System for 3 sunless days in a row. Batteries are to be mounted in the same pole/placed on foundations in a cabinet having IP 65 suitable for open environment. Each Siren should have 24/12V batteries inside controller, to ensure dissemination of warning messages in case of failure of AC mains power.Battery Backup should be sufficient days of idle running + minimum operations (5 messages of 6 duration each).The Solar Panel shall conform to IEC 61215 (Latest edition certificate) and IEC 61730. 2023. Approved Make: Vikram / Waaree / REIL /TATA Solar Reputed Make.
6
-
-
... More
For Supply, Testing, Designing, Erection and commissioning of Earthing of local station For the safety of all the installed Electrical and Electronic equipment, 02 meter 2 nos. at each location earthing must be done by the agency. Earthing is to be provided as per IS 3043:1996, ISI Standard Specification No: 732-1963 or latest edition.
6
-
-
... More
For Supply ,Testing, Designing, Erection and commissioning of Feedback Unit for status of Local Stations at Control Room All feedbacks (On, Off, Trip, Faults etc) of the equipment installed for Alert, Information and Direct system should communicate to main Control room SCADA.
6
-
-
... More
For Supply, Testing, Designing, Erection and commissioning of Emergency Push Buttons at Local Stations There should be provision of Operating the system from Local via Push buttons in case of Emergency.
6
-
-