Haryana Power Generation Corporation Limited Tender
... More
The HPGCL has issued a formal invitation for competitive bids for the Haryana Power Generation Corporation Limited project, for Amc Of Candi System Dcrtpp Yamunanagar in Yamuna Nagar, Haryana. The bid opening date for this tender is 02-05-2025 and the last date for bid submission is 31-05-2025. Interested bidders for Haryana Power Generation Corporation Limited tender can download the important documents here to check the tender amount, scope of work, eligibility criteria and technical requirements.
Haryana Power Generation Corporation Limited - HPGCL Tender
Civil And Construction
Building Construction
Eprocure
Opening Date2 May 2025
Closing Date31 May 2025
Tender AmountRefer Documents
Costs
EMD
₹ 3,47,631Document Cost
₹ 1,180Tender Fee
₹ 1,180
Summary
Amc Of Candi System Dcrtpp Yamunanagar
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_HBC_444477_1Tender No
2025F62C8FEC 19AF 4332 92CB 21A28021CA55711PGCTender Authority
Haryana Power Generation Corporation Limited ViewPurchaser Address
-Website
http://www.hpgcl.org.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Laying, testing & Termination of Cables Cable Size: 2.5X4 core (mtr)
1000
-
-
... More
Dismantling & Proper reinstallation of Equipments viz. Transmitters. Switches, Guages. Sensors, Vibration, Probes, Indicators, I/P Converter, Solenoid Valves Etc. including transportation
240
-
-
... More
PART B Removal & Installation of Pneumatic Actuators (Power Cylinder,newly installed DeNOx system etc including Transporation within Plant Premises.
120
-
-
... More
Jointing of Fibre Optical cable
10
-
-
... More
Removal, Servicing & Re installation Of Corner Valves.
100
-
-
... More
Any alteration, fabrication of structure, platform, canopies etc.(tonnes)
6
-
-
... More
Laying, testing & Termination of Cables Cable Size: 0.5X9 pair to 0.5X16 pair (mtr)
2000
-
-
... More
Supply of Painter
20
-
-
... More
Cable tray lying 300 mm and above
400
-
-
... More
Replacement of impulse lines by providing proper hangers/support.(mtr)
100
-
-
... More
Cleaning/Flushing of Impulse lines including cutting if required) which also involves dismantling & normalizing the lines after flushing and arresting of leakages if any.
160
-
-
... More
Cleaning/Servicing of Pneumatic Accessories Like positioners, Air Lock Relay, Air Filter Regulator, Solenoid Valve, Position Feedback Transmitters etc.
260
-
-
... More
Supply of skilled workforce
100
-
-
... More
Testing and replacement of Soot Blowers Rotary limit switches
120
-
-
... More
Removal & Installation of Motorized Regulating & adjustable actuators Including transportation within plant Premises.
100
-
-
... More
Cleaning of Choked Scanner guide pipe
200
-
-
... More
Cleaning of flow sensing elements (aerofoil) of PA flow measurement in the air duct.
60
-
-
... More
Supply of IBR Certified high Pressure welder
60
-
-
... More
Repair/welding in the impulse lineThermo well stubs & joints in case Of leakages, replacing of drain/isolating/Manifold valves etc (HP lines)
80
-
-
... More
Supply of unskilled labour
200
-
-
... More
Servicing/replacement of Soot Blowers Contactor assembly
20
-
-
... More
Cable tray lying From 100 to 200 mm
400
-
-
... More
Complete Servicing of Pneumatic Actuators (Diaphragm Operated or Power Cylinder or Solenoid operated. Or newly installed DeNOx system)
120
-
-
... More
Fabrication of FTE cable/Crimping Communication port.
60
-
-
... More
Removal/Servicing/Reinstallation of Scanners/Ignitor
250
-
-
... More
Arresting leakages from the fittings of the valve manifolds/level switches/Transmitters/flow switches, impulse Lines etc.
200
-
-
... More
Cleaning of CW flow/ secondary air flow sensing element (anubar) in CW duct/ secondary air duct resp.
40
-
-
... More
Laying, testing & Termination of Cables Cable Size: 1.5 X17 cores to 1.5 X24 core (mtr)
2000
-
-
... More
Calibration/Servicing of Equipment viz.Transmitters, Switches, Guages, Sensors,Vibration Probes, Indicator, I/P Converter, Smart Petitioners etc. including transportation.
240
-
-
... More
Repair/Welding in the impulse line,Thermo well stubs & joints in case Of leakages, replanning of draing/isolating/manifold valves etc (LP lines)
100
-
-
... More
PART A For smooth, execution of AMC for all C&I division works for Boiler Turbine & BOP of 300MW Unit-I & II, to carry out routine
/breakdown Mtc the contractor shall deploy the adequate technical teams to carry out routine /breakdown Mtc as enlisted below during working hours or at odd hours, including holidays: 1. Round the clock Routine/Preventive/Breakdown Maintenance of 32 nos. HEA Ignitors,& Oil guns 80 nos. Flame scanners. 120 nos. SADC’s, installed in Unit 1 & 2, ( on fortnightly basis as preventive Maintenance and in addition as per the Requirement). 2.Cleaning of PKS/FSC/DEH/VMS Operator & Engineering Workstations (38 nos.), Server Stations with PC (6nos.), Auto Tube Leakage Detection Station (2nos.), Printers (24 Nos.) along with tables, Control Panels in the DCS room (approx. 200nos.), Annunciation Panels (6 nos.), Large Video Screens (4nos.LEDS) fortnightly basis and in addition as per requirement. 3. Cleaning of panels installed at various sites (100nos.), Protection Boxes(380nos.) various junction boxes (Approx. 100 nos.) of Unit l &2 on fortnightly basis and in addition as per requirement.. 4. Round the clock Routine/Preventive/Breakdown maintenance of Pneumatic Actuators (Installed at various locations in the main plant & off sites) along with its accessories like Smart/ conventional Positioners, I IP converters, Air Filter Regulators, Air Lock Relays Solenoid valves, Copper/ SS tubing, Limit Switches, position feedback transmitter & I/P converters. Etc The total no of installed pneumatic actuators is approximately 400 nos. in Unit-1&2. 5. Round the clock Routine /Preventive/Breakdown maintenance of Wall & APH Soot Blowers (250 nos.appox.) installed Unit 1&2 which also includes Electrical Control Panel & accessories. 6. Round the clock Routine/Preventive/Breakdown maintenance of Motorized Regulating Adjustable Actuators (approx. 200 nos) in Unit- 1 & 2. 7. Round the clok Routine Cleaning of Oxygen analyser , SOX- NOX Analysers , CO Analysers & Opacity Monitors installed at various sites of Unit-1 & 2.
8. Round the clock Routine/Preventive/Breakdown maintenance of the equipments/system at different sites mentioned in Annexure-C at Sr. no. 20(i)
9.Any other C&I maintenance work/job which is not mentioned above,but required for smooth running of unit shall be in the scope of contractor.
24
-
-
... More
Cleaning of UPS Panel along with Connection tightening & contacts cleaning Of Battery bank terminals.(set)
40
-
-
... More
Complete Servicing of Motorized Regulating & adjustable Actuator
100
-
-
... More
Tasting and Replacement of Soot Blowers Motor
40
-
-
... More
Removal/Reinstallation of Analytical Instruments e.g. PH, Conductivity, Chlorine,Oxygen, Co, Opacity Sox-Nox Hydrastep Electrode, Camera, Sonic Probe etc.
70
-
-
... More
Laying, testing & Termination of Cables Cable Size: 0.5X1 pair to 0.5X8 pair (mtr)
2000
-
-
... More
Cable tray lying Up to 50mm (meter)
800
-
-