Gurugram Metropolitan Development Authority Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 2,17,15,000Document Cost
₹ 1,000Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_HRY_238422_1Bid Award Id
ViewTender No
2022BF7CD8CE 0BD8 406A 846D E7716E3582BD717001Tender Authority
Gurugram Metropolitan Development Authority ViewPurchaser Address
-Website
http://https://haryana.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Complete Electrical and Instrumentation Work of Main Sewage Pumping Station Tapping of outfall of sewage and Intake from nearest Manhole (excluding sewer line 200 mm taken separately in BOQ) and Design, drawing, construction of Main Sewage Pumping stations as detailed below consisting of extension of any other existing sewer to MPS, inlet chamber with sluice gate, screening chamber with screens , collecting tank, CI/DI double flanged delivery pipe , NRVs, dismantling pieces, gate valves, header pipe , specials, lifting arrangement with RS joist and chain pullet block (5T) along with supplying, installation, testing and commissioning of non- clog sewage submersible pumping sets fitted with efficient motor , mechanical seal, thermal and moisture sensors, suspension device, auto coupling bracket, guide pipe, panel, panel room, Genset, all other building , electrical, mechanical, civil works complete in all respect as per scope of work and specification provided in tender Document including Operation and Maintenance cost for MPS and all other allied works as per details provided in tender, under the contract for 10 years as well as for defect liability period of 12 months which includes basic service charges having expenditure and expenses required to be incurred on labour, repair and / or replacement of materials, equipments, consumable items, water and all other matters and items of what so ever nature, essential and desirable to run the system satisfactory, Comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, as per Scope of Work and terms and conditions of contract etc. complete. (OandM Cost shall be minimum 20% of total project cost for total 10Yr plus 1 yr DLP total 11 yrs OandM) Note:- Component Cost includes both capital and OandM Cost.
1
-
-
Complete Mechanical Work of 100 MLD Sewage Treatment Plant with Power Generation- Design, drawing, construction, supply, installation, testing and commissioning (including 3 months trial run) of 100 MLD Sewage Treatment Plant with min. power generation as defined in the DNIT, below based on SBR Technology consisting of inlet chamber, screening chamber, grit chamber, Equalization tank, Primary Clarifier, selector tanks, SBR basin, complete power generation system -Sludge Digester, gas dome, flare system, scrubber, gas engine etc., chlorine contact tank, sludge handling system - Belt Filter Press, Transformer, power station - connect to grid the generated power, CCTV cameras, Online Monitoring arrangement for laboratory for measurement of various parameters of untreated and treated effluent etc., complete in all respects as per scope of work and detailed specifications mentioned in the Bid document including all civil, mechanical, Electrical, Instrumentation etc. and all other relevant works. The work also includes provision for treated waste water to the drain (if required as per the site requirement) and also includes providing street lighting in campus complete in all respects as per specifications and directions of Engineer-in-Charge. In addition to this equipment at the testing laboratory shall be provided at Dhanwapur only as per the specification. Online Analyzer. etc. and Operation and Maintenance - Operation and maintenance cost for STP, all other works created under the contract for 10 years as well as for defect liability period of 12 months which includes basic service charges having expenditure and expenses required to be incurred on labour, repair and / or replacement of materials, equipments, consumable items, water and all other matters and items of what so ever nature, essential and desirable to run the system satisfactory, Administration and Management, Running of Office, Comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, other Consumables (except Polyelectrolyte and chlorine taken separately in BOQ) as per Scope of Work and terms and conditions of contract etc. complete. (OandM Cost shall be minimum 20% of total project cost for total 10 plus 1 yr DLP total 11 yrs OandM) Note:- Component Cost includes both capital and OandM Cost.
1
-
-
Complete Mechanical Work of Main Sewage Pumping Station Tapping of outfall of sewage and Intake from nearest Manhole (excluding sewer line 200 mm taken separately in BOQ) and Design, drawing, construction of Main Sewage Pumping stations as detailed below consisting of extension of any other existing sewer to MPS, inlet chamber with sluice gate, screening chamber with screens , collecting tank, CI/DI double flanged delivery pipe , NRVs, dismantling pieces, gate valves, header pipe , specials, lifting arrangement with RS joist and chain pullet block (5T) along with supplying, installation, testing and commissioning of non- clog sewage submersible pumping sets fitted with efficient motor , mechanical seal, thermal and moisture sensors, suspension device, auto coupling bracket, guide pipe, panel, panel room, Genset, all other building , electrical, mechanical, civil works complete in all respect as per scope of work and specification provided in tender Document including Operation and Maintenance cost for MPS and all other allied works as per details provided in tender, under the contract for 10 years as well as for defect liability period of 12 months which includes basic service charges having expenditure and expenses required to be incurred on labour, repair and / or replacement of materials, equipments, consumable items, water and all other matters and items of what so ever nature, essential and desirable to run the system satisfactory, Comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, as per Scope of Work and terms and conditions of contract etc. complete. (OandM Cost shall be minimum 20% of total project cost for total 10Yr plus 1 yr DLP total 11 yrs OandM) Note:- Component Cost includes both capital and OandM Cost.
1
-
-
Design and construction of CC Pavement of minimum 2 mtr width to connect all units to internal roads with 100 mm thickness PCC 1:1.5:3 OVER 100 mm thick 1:3:6 alongwith provision of kerbs and channel with suitable opening ofor disposal of storm water runoff in front of buildings and electrical panel rooms including OandM for 11 years including 1 year DLP
800
-
-
Design and construction of internal approach road of 4 mtr width with cement concrete M-30 grade 250 mm thickness over a base of 150 mm thick wet mix macadam over 150 mm granular sub base layer according to Morth Specification including OandM for 11 years including 1 year DLP
1200
-
-
Design and construction of storm water drain including OandM for 11 years including 1 year DLP
2000
-
-
Designing and constructing of RCC M-25 framed structure conforming to National Building Code for Blower building (Ground floor) and other contingent work thereto as per sizes and specification given in DNIT including OandM for 11 years including 1 year DLP
550
-
-
Designing and constructing of RCC M-25 framed structure conforming to National Building Code for Blower, PLC and MCC building (First floor) and other contingent work thereto as per sizes and specification given in DNIT including OandM for 11 years including 1 year DLP
550
-
-
Designing and constructing of RCC M-25 framed structure conforming to National Building Code for Chemical building and other contingent work thereto as per sizes and specification given in DNIT including OandM for 11 years including 1 year DLP
200
-
-
Designing and constructing of RCC M-25 framed structure conforming to National Building Code for Chlorination cum Chlorine tonner house and other contingent work thereto as per sizes and specification given in DNIT including OandM for 11 years including 1 year DLP
175
-
-
Designing and constructing of RCC M-25 framed structure conforming to National Building Code for Control room and other contingent work thereto as per sizes and specification given in DNIT including OandM for 11 years including 1 year DLP
50
-
-
Designing and constructing of RCC M-25 framed structure conforming to National Building Code for MCC and Electrical Panel room and other contingent work thereto as per sizes and specification given in DNIT including OandM for 11 years including 1 year DLP
150
-
-
Designing and constructing of RCC M-25 framed structure conforming to National Building Code for Mtc. Workshop, metering room, DG Set room, battery room, security guard room and other contingent work thereto as per sizes and specification given in DNIT including OandM for 11 years including 1 year DLP
183.75
-
-
Designing and constructing of RCC M-25 framed structure conforming to National Building Code for transformer yard and other contingent work thereto as per sizes and specification given in DNIT including OandM for 11 years including 1 year DLP
70
-
-
Landscaping and horticulture including OandM for 11 years including 1 year DLP
4000
-
-
Providing, lowering, cutting, jointing, testing and commissioning of 2000mm i/d RCC NP3 pipe with 2.5mm thick HDPE lining alongwith construction of manholes, dewatering and dismantling of existing road, if any and its reconstruction including OandM for 11 years including 1 year DLP
150
-
-
Provision of Chlorine as per actual consumption
4015044
-
-
Provision of Poly Electrolyte as per actual consumption
341220
-
-
Repair of existing Admin. Building conforming to National Building Code and other contingent work thereto including OandM for 11 years including 1 year DLP as per specification given in DNIT.
1
-
-
Supply and fixing of Signages as per norms including OandM for 11 years including 1 year DLP
300
-
-
Supply, laying, cutting, jointing, testing and commissioning of Rising Main minimum 1200 mm dia DI K9 including excavation for carrying pumped untreated effluent from MPS to STP and other allied works including OandM for 11 years including 1 year DLP
300
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements