The Central University Of Haryana has issued a formal invitation for competitive bids for Annual Repair And Maintenance Of Variable Refrigerant Flow Vrf Type Hvac Air Conditioning System Including Window And Split Ac Installed At Various Buildings Like Academic Block I Iii Iv Vice Chancellor Residence Cum Camp Office And Prof Mool Chand in Mahendragarh, Haryana, with an estimated contract value of Rs. 36,48,726. The bid opening date for this tender is 08-05-2025 and the last date for bid submission is 15-05-2025. Interested bidders for Central University Of Haryana tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Central University Of Haryana Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 May 2025
Closing Date15 May 2025
Tender Amount₹ 36,48,726 
Notes
Download

Costs

Summary

Annual Repair And Maintenance Of Variable Refrigerant Flow Vrf Type Hvac Air Conditioning System Including Window And Split Ac Installed At Various Buildings Like Academic Block I Iii Iv Vice Chancellor Residence Cum Camp Office And Prof Mool Chand

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying, Replacement Testing & Commissioning of faulty Inverter PCB with new one of following capacity inverter type PCB in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 10 HP Outdoor inverter PCB

1

33500

33500

... More
Supplying, Replacement Testing & Commissioning of faulty Inverter PCB with new one of following capacity inverter type PCB in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 12 HP Outdoor inverter PCB

1

32500

32500

... More
Supplying, Replacement Testing & Commissioning of faulty Inverter PCB with new one of following capacity inverter type PCB in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 10 HP Outdoor Fan PCB

1

30500

30500

... More
Supplying, Replacement, Testing & Commissioning of faulty Display PCB with new one of following capacity Outdoor Display PCB in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 12 HP Outdoor Display PCB

1

42000

42000

... More
Supplying, Replacement, Testing & Commissioning of faulty Display PCB with new one of following capacity Outdoor Display PCB in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 10 HP Outdoor Display PCB

1

40000

40000

... More
Supplying, Replacement, Testing & Commissioning of faulty Transistor module with new one of following capacity outdoor Transistor module in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 12 HP Outdoor Transistor module

1

32950

32950

... More
Supplying, Replacement, Testing & Commissioning of faulty Transistor module with new one of following capacity outdoor Transistor module in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 10 HP Outdoor Transistor module

1

30950

30950

... More
Supplying, Replacement, Testing & Commissioning of faulty Diode Module with new one of following capacity outdoor diode module in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles,cleaning etc. complete as required. 12 HP Outdoor Diode module

1

9500

9500

... More
Supplying, Replacement, Testing & Commissioning of faulty Diode Module with new one of following capacity outdoor diode module in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles,cleaning etc. complete as required. 10 HP Outdoor Diode module

1

9100

9100

... More
Supplying, Replacement, Testing & Commissioning of faulty Cement Resistor with new one of following capacity Outdoor Cement Resistor in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 12 HP Outdoor Cement Resistor

1

3500

3500

... More
Supplying, Replacement, Testing & Commissioning of faulty Cement Resistor with new one of following capacity Outdoor Cement Resistor in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 10 HP Outdoor Cement Resistor

1

3400

3400

... More
Supplying, Replacement, Testing & Commissioning of faulty harness with new one of following capacity outdoor harness in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 12/10 HP Outdoor harness

25

1250

31250

... More
Supplying, Replacement, Testing & Commissioning of faulty Compressor contractor Relay 3 Pole with new one of following capacity compressor contractor relay in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 12/10 HP Outdoor Compressor contractor Relay 3 Pole

6

8500

51000

... More
Supplying, Replacement, Testing & Commissioning of faulty Discharge Sensor with new one of following capacity outdoor Discharge Sensor in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 12/10 HP Outdoor Discharge Sensor

5

4500

22500

... More
Servicing, Repairing of following VRF Outdoor unit installed at various location including cleaning of cooling coil compressor, blower, fan & greasing as where required and replacement of burned wired & repairing of Communication Fault etc. complete as required. 12/10 HP Servicing of VRF Outdoor unit

169

2000

338000

... More
Supplying, Replacement, Testing & Commissioning of faulty Outdoor Fan Motor with new one of following capacity outdoor Outdoor Fan Motor in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 12 HP Outdoor Fan Motor

1

16500

16500

... More
Supplying, Replacement, Testing & Commissioning of faulty Outdoor Fan Motor with new one of following capacity outdoor Outdoor Fan Motor in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 10 HP Outdoor Fan Motor

1

15500

15500

... More
Supplying, Replacement, Testing & Commissioning of faulty Main PCB with new one of following capacity Indoor main PCB in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 8 HP Indoor Main PCB

1

45650

45650

... More
Supplying, Replacement, Testing & Commissioning of faulty Main PCB with new one of following capacity Indoor main PCB in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 5 HP Indoor Main PCB

1

43650

43650

... More
Supplying, Replacement, Testing & Commissioning of faulty Main PCB with new one of following capacity Indoor main PCB in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 3.5 HP Indoor Main PCB

1

40650

40650

... More
Supplying, Replacement, Testing & Commissioning of faulty Fan PCB with new one of following capacity Indoor Fan PCB in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles,cleaning etc. complete as required. 8 HP Indoor Fan PCB

1

10800

10800

... More
Supplying, Replacement, Testing & Commissioning of faulty Fan PCB with new one of following capacity Indoor Fan PCB in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles,cleaning etc. complete as required. 5 HP Indoor Fan PCB

1

9500

9500

... More
Supplying, Replacement, Testing & Commissioning of faulty Fan PCB with new one of following capacity Indoor Fan PCB in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles,cleaning etc. complete as required. 3.5 HP Indoor Fan PCB

1

8500

8500

... More
Supplying, Replacement, Testing & Commissioning of faulty Display PCB with new one of following capacity Indoor Display PCB in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles,cleaning etc. complete as required. 8 HP Indoor Display PCB

1

3600

3600

... More
Supplying, Replacement, Testing & Commissioning of faulty Display PCB with new one of following capacity Indoor Display PCB in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles,cleaning etc. complete as required. 5 HP Indoor Display PCB

1

3200

3200

... More
Supplying, Replacement, Testing & Commissioning of faulty Drain Pump with new one of following capacity Indoor Drain Pump in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles,cleaning etc. complete as required. 5/3.5 HP Indoor Drain Pump

1

6000

6000

... More
Supplying, Replacement, Testing & Commissioning of faulty Fluid Sensor with new one of following capacity Indoor Fluid Sensor in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 5/3.5 HP Indoor Fluid Sensor

1

1250

1250

... More
Supplying, Replacement, Testing & Commissioning of faulty Gas Sensor with new one of following capacity Indoor Gas Sensor in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles,cleaning etc. complete as required. 5/3.5 HP Indoor Gas Sensor

1

1530

1530

... More
Supplying, Replacement, Testing & Commissioning of faulty Suction Sensor with new one of following capacity Indoor Suction Sensor in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 5/3.5 HP Indoor Suction Sensor

1

1530

1530

... More
Supplying, Replacement, Testing & Commissioning of faulty Discharge Sensor with new one of following capacity Indoor Discharge Sensor in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 5/3.5 HP Indoor Discharge Sensor

1

1530

1530

... More
Supplying & Charging of fresh refrigerant (wherever required) R-410 A in existing outdoor unit VRV/VRF & Non VRF system after detecting and removing the leakage, pressure testing with nitrogen, vaccumising the system and charging the fresh refrigerant testing & commissioning etc. as required.

125

6500

812500

... More
Servicing, Repairing of following VRF Indoor unit installed at various location including cleaning of cooling coil compressors, blower, fan & greasing as where required and replacement of burned wired & repairing of Communication Fault etc. complete as required. 8/5/3.5/2/1.5 TR Servicing of VRF Indoor unit

883

400

353200

... More
Supplying and Laying of 2x1.5 multi-core PVC insulated, PVC sheathed unarmored Bare round copper conductor, control/ communication cable in the existing cable tray/conduit with suitable calim /saddens including testing commission etc. as required. 2x1.5 sq.mm. multi-core control cable

130

250

32500

... More
Supplying, Replacement, Testing & Commissioning of faulty Indoor Fan Motor with new one of following capacity outdoor indoor Fan Motor in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 8 HP Indoor Fan Motor

1

14500

14500

... More
Supplying, Replacement, Testing & Commissioning of faulty Indoor Fan Motor with new one of following capacity outdoor indoor Fan Motor in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 5 HP Indoor Fan Motor

1

12500

12500

... More
Supplying, Replacement, Testing & Commissioning of faulty Indoor Fan Motor with new one of following capacity outdoor indoor Fan Motor in existing VRV/VRF system of voltas make including checking all parts of indoor/ outdoor units are properly connected etc. connections, interconnection all the electrical wiring with thimbles, cleaning etc. complete as required. 3.5 HP Indoor Fan Motor

1

10500

10500

... More
Supplying, Replacement, Testing & Commissioning of complete out door panel with new one of following capacity in existing VRV/VRF system of voltas make including all type of PCB, Sensors, Connection Cable & connection with suitable size of suction of discharge copper pipe, brazing the all joints and removing of leakages, vaccumizing the system, presure testing with nitrogen gas of the system (for 24 hrs) etc, connections, interconnection all the electrical wiring with thimbles,cleaning etc. complete as required. 12 HP Outdoor Complete Out Door Panel

3

135000

405000

... More
Supplying, Replacement, Testing & Commissioning of complete out door panel with new one of following capacity in existing VRV/VRF system of voltas make including all type of PCB, Sensors, Connection Cable & connection with suitable size of suction of discharge copper pipe, brazing the all joints and removing of leakages, vaccumizing the system, presure testing with nitrogen gas of the system (for 24 hrs) etc, connections, interconnection all the electrical wiring with thimbles,cleaning etc. complete as required. 10 HP Outdoor Complete Out Door Panel

4

125000

500000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.