Gujarat Industrial Development Corporation Tender
... More
The GIDC has issued a formal invitation for competitive bids for the Gujarat Industrial Development Corporation project, for Development Of Parking Facility For Plot No. S-85 At Dahej-i ,gidc, Industrial Estate in Bharuch, Gujarat, with an estimated contract value of Rs. 20,07,99,803. The bid opening date for this tender is 03-11-2026 and the last date for bid submission is 25-11-2026. Interested bidders for Gujarat Industrial Development Corporation tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Gujarat Industrial Development Corporation - GIDC Tender - Gujarat Tender
Opening Date3 Nov 2026
Closing Date25 Nov 2026
Tender Amount₹ 20,07,99,803.4
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
₹ 21,240
Description
Development Of Parking Facility For Plot No. S-85 At Dahej-i ,gidc, Industrial Estate
AI Insights
Unlock AI Insights for this Tender
Sign in to request AI-powered insights, eligibility criteria and automated analysis for this tender.
Contact
Tender Id
362448Tender No
E-Tender Notice No. 07 of 2026-27 Sr. No. 02Tender Authority
Gujarat Industrial Development Corporation ViewPurchaser Address
-Website
https://gidc.gujarat.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Installation of Factory-Made Precast Drain including lid cover & Culvert for various Size as per below. Installation of factory-made Precast Drain & Culvert units in proper line level including cement mortar of 20 mm and alignment completed as directed by EIC or any concern authorities. The rate is including Unloading and installation with joining of elements with proper techniques and standards of MFG, Machineries, Taxation, material and labour charges. Unloading and installation with joining of elements with proper techniques and standards for Precast Concrete Box Culvert Specifications should be confirming as per standard as below or other equivalent standards.
-
-
-
... More
c) 2.5 m X 2.5 m (In to In)
24
-
-
... More
DESIGN AND CONSTRUCTION OF Building Canteen 100 Sq.m. WITH CONVENTIONAL IN SITU FOUNDATION & PCC Plinth including Construction of superstructure using COLUMNS, BEAMS, SLABS AND NON-LOAD BEARING PARTITION WALLS (Masonry/Plaster) as per Architect’s drawings. provision of all embedded Electrical & Plumbing conduits as per detailed MEP drawings to be prepared and fixing the smooth finish exposed concrete quality (dimensional tolerance as per Indian Standard Guidelines) structural elements of M-25(Footing, Columns, Beams), M-20(Slab) of concrete without using Portland Pozzolanic Cement & Fly ash incl. providing and applying 2 coats of WPM 004, two components acrylic modified flexible cementitious waterproof coating and China mosaic water proofing treatment with Koba concrete on terrace; including providing approved quality putty on the inside along with interior emulsion paint of approved makes and on the outside primer with 2 coats of approved quality exterior weather paint or texture of approved makes and as per Architect’s drawings and as per General specifications. of tender. (Rate inclusive of Prepare Architect Drawing, Electrical Drawing, structural design and construction. and other Relevant items like Brick work, plaster, Granite, Door Frame, Window Frame, Fully Pannel Door, Aluminium Section Window, Vitrified Tiles, Skirting, kitchen platform, sink, Plumbing, Electrical etc. complete as directed by engineer-in-charge.
1
-
-
... More
b) 1.20 m X 1.20 m (In to In)
605
-
-
... More
b) 0.90 m X 0.90 m (In to In)
650
-
-
... More
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg. /Sq. Cm. wall Cement Mortar 1:5. (1- Cement: 5 -fine sand) (B) Conventional at all height & directed by engineer-in-charge.
230
-
-
... More
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering.
194
-
-
... More
Regulatory / Mandatory sign boards providing & fixing sign boards made out of 2 mm aluminium sheet size 60 cms. Diameter circle as per the design of IRC-67-1977 Pre-treated with phosphating process & acid etching; coated with one coat of epoxy primer and two coats of best quality epoxy paint reflectorised with retro reflective sheeting as per latest M.O.S.T. Specifications: 3.1 mt long stand post and frame fabricated from suitable size iron angle of 35x35x3 mm .75x75x6 mm as required; paint with best quality epoxy coating in black and white bends. The details of symbol for each board shall be as per the instruction of engineer in charge. The fixing at site shall be in 1:2:4 CC blocks of size 45 x 45 x 60 cms. For each leg. Including excavation curing etc. complete under the supervision of engineer.
20
-
-
... More
Construction of granular sub-base by providing & laying of compacted thickness of 200 mm Grading 5th Granular sub base (GSB) of Contractor in layers of (150 mm with geocell + 50 mm) of graded granular material consisting of machine cut black trap stone aggregate as per grading - V given in table 400-1 of the specification MORT&H and compactor to the required density with vibratory roller in all seasons as per MORT&H , maintaining the required slope & grade during the operation as approved by the engineer in charge & watering to the proper moisture content and sprinkled with the help of truck mounted water tank fitted with suitable arrangement. (fully saturated having CBR value minimum 30)
6567
-
-
... More
a) 0.6 m X 0.6 m (In to In)
24
-
-
... More
Providing & fixing flush door shutters, solid core construction with frame of 1st class hard wood with cross band and face veneer or plywood face panels including anodized aluminum butt hinges with necessary screws (B) Non-decorative type and block board core. (2) 35 mm. thick. ( Approved brand of flush door Swastik (kitply), Greenply ,Duro, Archidply , Anchor or which is approved by authority.)
2.1
-
-
... More
Providing ISI Mark TMT bar Fe 500-D with factory made epoxy coated reinforcement for R.C.C. work including, bending, binding and placing in position complete up to floor two level etc. complete as directed by Engineer in charge.
82167.6
-
-
... More
20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete.
6812
-
-
... More
Excavation for foundation upto 1.5m depth including sorting out and stacking of useful materials and disposing off the excavated stuff up to any lead as directed by engineer in charge.
22392.14
-
-
... More
Providing and fixing adjustable stainless-steel clamps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc. complete as per direction of the Engineer-in-charge.
3342
-
-
... More
Supplying and fixing reinforced concrete heavy duty nonpressure pipes with collars for culverts including setting and joining the pipes in C.M. 1:2 watering and laying To level of slops of I.S. 458 / 1971 Class NP3 casted by vertically vibrated technology of following internal diameter. (i) 300 mm dia.
1011.88
-
-
... More
Boring holes 3.5 m deep in ordinary soil (for cast in situ piles) and getting out the soil and disposal of the surplus excavated soil as directed within any lead and lift for following diameter of pipes.(iii) 300 mm, Add to or deduct from the rate for Bore Holes of 3.5 m Depth, if bore holes are made deeper or shallower than 3.5M. for Piles of following diameter.(iii) 300 mm. Extra for under reaming inside the bore Holes for under reamed piles of following Diameter.(iii) 300 mm.
406
-
-
... More
Providing and laying controlled cement concrete work M200 and curing complete including scaffolding centering, formwork, needle vibrated consolidation, curing complete up to 6 meter depth or height (excluding cost of reinforcement and neat finishing) with centering and shuttering/deshuttering etc. complete for structure other than water retaining
271
-
-
... More
Providing and fixing Pre-Moulded bituminous joint Filler 25mm size at wall expansion joint
39.74
-
-
... More
Providing and laying controlled cement concrete work M250 and curing complete including scaffolding centering, formwork, needle vibrated consolidation, curing complete as per drawing (excluding cost of reinforcement) incl. formwork, centering and shuttering/de-shuttering etc. complete at all depth & directed by engineer-in-charge. (For Foundation, Footings, Base of Columns).
70
-
-
... More
Providing and laying cement concrete 1:2:4 (1-Cement :2-coarse sand :4 graded stone aggregates 20 mm nominal size) and curing complete incl. dewatering and excluding cost of formwork and reinforcement etc. as directed by engineer-in-charge.
85
-
-
... More
Construction of Sub-base using lime Copper Slag admixture with excavated sub base soil, free from organic matter deleterious material or clayey silts and low plasticity clays having PI between 5 and 20 and liquid limit less than 25 and commercial dry lime, slaked at site or pre slaked with CaO content not less than 70 per cent, Copper slag, lime minimum 4.00Percentage +Copper Slag 35Percentage by wight, the minimum un- confined compressive strength and CBR value after 28 days curing and 4 days soaking to be 7.5kg per sq. cm and 8 per cent respectively.
13127.23
-
-
... More
Providing & Laying water proofing treatment with China mosaic tiles flooring over an average bed of 50 mm thick C.C. 1 : 2:4 & 12 mm thick C.M. 1:3 using glazed tiles pieces of required size laid as directed at 3 mm to 5mm apart including all labour materials and finished with flush pointing in white cement etc. all complete as directed by engineer-in-charge.
100
-
-
... More
Boring holes 3.5 m deep in ordinary soil (for cast in situ piles) and getting out the soil and disposal of the surplus excavated soil as directed within a lead of 50 Meter for following diameter of pipes.(iii) 300 mm, Add to or deduct from the rate for Bore Holes of 3.5 m Depth, if bore holes are made deeper or shallower than 3.5M. for Piles of following diameter.(iii) 300 mm. Extra for under reaming inside the bore Holes for under reamed piles of following Diameter.(iii) 300 mm .
48
-
-
... More
Stop sign boards providing & fixing sign boards made out of 2 mm aluminium sheet size 90 x 90 cms. octagon as per the design of IRC-67-1977 Pre-treated with phosphating process & acid etching; coated with one coat of epoxy primer and two coats of best quality epoxy paint reflectorised with retro reflective sheeting as per latest M.O.S.T. Specifications: 3.1 mt long stand post and frame fabricated from suitable size iron angle of 35x35x3 mm .75x75x6 mm as required; paint with best quality epoxy coating in black and white bends. The details of symbol for each board shall be as per the instruction of engineer in charge. The fixing at site shall be in 1:2:4 CC blocks of size 45 x 45 x 60 cms. For each leg. Including excavation curing etc. complete under the supervision of engineer.
15
-
-
... More
b) 0.80 m X 0.90 m (In to In)
1028
-
-
... More
Standard Delineator: Providing and fixing of Standard Metal Delineator consisting of minimum retro reflective unit exposed area of 330 cm2 white color, full cube corner micro prismatic non-metallic retro reflective sheeting on each side conforming with IRC 67 2012 and meeting the coefficient of retro reflection values as per ASTM D 4956 Type XI table of Contractor specification. The delineator shall be painted with powder coat of minimum 40 microns thickness, on top of which retro reflective sheeting shall be pasted on both sides. The structure shall be manufactured in roll forming process and shall have height not less than 800 mm above the ground, width not less than 100 mm and shall extend not more than 300mm below the ground while being installed. height of sheeting should be minimum 150mm whereas width of sheeting should not be less than 75mm (should be placed every alternative 15cm). The front and back faces of the delineator should be curved with a radius of not more than 200 mm and with delta angle (or central angle of curve) lying between 20o and 30o, to increase the visibility of the delineator for vehicles moving in continuous curves. The delineator shall have grooves across the length to make the reflective sheets vandal-proof. The delineator is meant for application on gaps in median, traffic islands, dangerous bends, roundabouts, narrow bridges etc. or as desired by site engineer.
300
-
-
... More
Providing 20 mm thick double coat mala cement plaster on interior & exterior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement: 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement: 2 Coarse sand) finished with trovel including scaffolding curing etc. complete at all height and directed by engineer-in-charge. (External Plaster)
470
-
-
... More
Providing and fixing dry cladding up to 10-meter heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size up to 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). White sand stone - 30mm thick gang saw cut stone.
477.4
-
-
... More
Kerb Painting of approved colour make and shade including all material, Labour and lead etc. completed and making the road surface clean. (Kerb size 30 cm Ht & 30 Cm Length).
706.5
-
-
... More
Providing and laying PCC (1:3:6) [1: cement, 3: coarse sand, 6: graded stone aggregate 40 mm nominal size] and curing, Excluding the cost of form work etc. complete in foundation & plinth.
470.33
-
-
... More
Development of landscape garden at area of parking at GIDC Dahej. By Removal and excavation of unwanted bushes and material upto 30 cm dept, Cleaning and removal of roots from the area and level the same. Adding and spreading good garden soil, fertilizer, spreading pesticides and growth promoters with help of manpower with tools and tackles as required machinery and lifting waste material out of area. leveling proper area. Making Hilok mountain in 30 Percentage of area height of mountain l .5mtr to 2 mtr. development of garden and landscape with carpet lawn, Trees, palms, hedge and ornamental shrubs for beautification of area. Plantation with be done by adding required soil, growth promoters and pesticides as required for healthy growth of plants. In additional to above we will be making water body with plastic layout in which lotus will be planted for making it estate chainlink angle fencing.
5155.97
-
-
... More
Designing (aesthetically & structurally) & Construction of 60 Sqm toilet block, septic tank, soak pit & pipe line arrangement as per design and drawing including filling in plinth with sand under floors including watering, ramming consolidating and dressing etc. complete, doors & windows of aluminium section and window grill of iron/Aluminium, panelled Door etc. complete up to floor to height 3.5 m, In RCC frame structure including Brick/Autoclaved cement concrete block masonry fillers walls of min 200 mm thickness with 15 mm thick inside plaster in 1:2 cement mortar & two coats of 20 mm thick sand faced outside plaster with weather plaster proof painting outside & acrylic painting inside with Aluminium frame & shutters partly glazed doors & Aluminium Frame & shutters with fully glazed windows having extruded Aluminium frame colour anodized/powder coating of size 127 mm X 38.1 mm X 1.35 mm weighing 1.38 kg/m & door shutters of 127 mm X 38.1 mm X 1.35 mm weighing 1.35, kg/m & window shutters of 122.20 mm X 31.75 mm X 1.10 mm weighing 1.20 kg/m with 5 mm transparent float glass in all shutters. including powder coated Aluminium fittings & fixtures with transparent silicon sealant glass fixing to the frame with granite jams & sills & lintels on outer sides of wall openings. It also includes RO Water Purifier System of min 10 litter/hours and Mirror Polished Kota stone Sandwiched Granite Platform of total 2 m length x 0.75 m width with Mirror Polished Kotstone Sandwiched single piece Supports spaced as directed by Engineer in Charge. Ceramic Sink with water tap & 1000 Liter Plastic overhead water tank & plumbing system & drainage system etc. It is also included construction of toilet block with all accessories like ceramic tiles flooring, dedo, taps, WC, urinal, washbasin, etc. complete as per instruction and directed by Engineer‐in‐charge.
2
-
-
... More
SITC of 6 mt automatic Boom barrier with photo sensors, remote, push button, Ac / DC motor necessary hardware etc. complete as per instructions by Architect or Engineer - in – Charge.
2
-
-
... More
Parking sign boards providing & fixing sign boards made out of 2 mm aluminium sheet size 60 x 60 cms. square plus 60 x 20 cms rectangular additional plates as per the design of IRC-67-1977 Pre-treated with phosphating process & acid etching; coated with one coat of epoxy primer and two coats of best quality epoxy paint reflectorised with retro reflective sheeting as per latest M.O.S.T. Specifications: 3.1 mt long stand post and frame fabricated from suitable size iron angle of 35x35x3 mm .75x75x6 mm as required; paint with best quality epoxy coating in black and white bends. The details of symbol for each board shall be as per the instruction of engineer in charge. The fixing at site shall be in 1:2:4 CC blocks of size 45 x 45 x 60 cms. For each leg. Including excavation curing etc. complete under the supervision of engineer.
15
-
-
... More
Providing and laying controlled cement concrete work M250 and curing complete including scaffolding centering, formwork, needle vibrated consolidation, curing complete as per drawing (excluding cost of reinforcement) Incl. formwork, centering and shuttering/de-shuttering etc. complete at all height & directed by engineer-in-charge. (For Slab, Lintels, Beams, Girders and Cantilever).
35.9
-
-
... More
Clearing and grubbing road land including uprooting rank vegetation grass bushes, shrubs, sapling and trees girth up to 300 mm removal of stumps of trees cut earlier and disposal of unserviceable materials (C) By mechanical means in area of light jungle
2.5
-
-
... More
Providing, fabricating & fixing Structural steel work (Confirming to IS 4923-1997) riveted, bolted or welded in built up for all type sections, in framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint, brushing, interior to give an even shade including cleaning the surface an even shade including cleaning the surface of all dirt, dust and other foreign matter. all complete as per the structural designs and directions of Engineer in charge.
16709
-
-
... More
Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth.
6811.98
-
-
... More
c) 2.5 m X 2.5 m (In to In)
24
-
-
... More
Excavation for foundation in Loose or soft soil up to 1.5 m. depth including sorting out and stacking of useful materials and disposing of the excavated stuff up to 50-meter Lead as directed by Engineer in charge.
479
-
-
... More
a) 0.6 m X 0.6 m (In to In)
40
-
-
... More
Providing and laying controlled cement concrete M-250 for R.C.C. bored piles of 1.20 Mt. diameter including ramming, vibrating and finishing complete.
213
-
-
... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, of Contractor finishing and curing etc completed as directed by-engineer-in-charge.
3283.5
-
-
... More
Providing, fabricating, erecting placing in position and connecting MS structural sections ( I-section, Channel section, Angles, Insert plates etc.) in roof trusses, columns, portal frames, beams, bracing, platforms, stairs & column nosing angle, brackets, etc. including cutting, wastage, welding (shop and site), bolting wherever necessary, with one coat of red oxide primer and two coats of approved colour enamel paint of M/s Berger or equivalent etc. all complete as directed by the Engineer.
310
-
-
... More
Road marking with hot applied thermoplastic paints with reflectorising glass beads on bitumen surface providing and laying a hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @ 250gms per sqm area, thickness of 2.5mm is excluding of surface applied glass beds as per IRC:35- 2015. The finished surface to be level, uniform and free from streaks and holes. zebra Patta /bump Patta Lane/centre line/ edge line/cut Patta/signs/writing. The white colour marking should provide luminance coefficient on cement road shall be min 130 mcd/m2/lux and Asphalt Road shall be min 100 mcd/m2/lux of Contractor during the service life during the day time. The marking should meet the performance criteria for night time reflectivity, wet reflectivity and skid resistance as mentioned in the section-15 of IRC 35-2015. Warranty for the Retro reflectivity should be two years.
1550
-
-
... More
a) 0.6 m X 0.6 m (In to in)
40
-
-
... More
Supplying of Solar Raised Pavement Markers made of polycarbonate moulded body with circular shape, solar powered, LED self- illumination in active mode, 360-degree illumination and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face in passive mode. The marker shall support a load of 20000 kg tested in accordance to ASTM D 4280. The marker should be resistant to dust and water ingress according to IP 65 standards and should withstand temperatures in the range of 0 C to 70 C. Color of lighting could be provided in red or yellow (amber) as per requirement and typical frequency of blinking is 1 Hz. There should be current losses of less than 20 micro-amperes at 2.4 V in sleep- charging mode to enhance the life of the marker and a full charge should provide for a minimum autonomy of 50 hours. The height, width and length of the marker shall not be less than 10 mm x 100 mm x 100 mm. Also, the surface diameter of the marker shall not be less than 100 mm respectively. The weight of the marker shall not exceed 0.5 Kilograms. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin-based adhesive as per manufacturers recommendation and complete as directed by the engineer.
1110
-
-
... More
Providing and Laying of Window Sill, lintel and jems of 19 mm thick granite of Approved colour and design as per instructions by Engineer - in – Charge.
10.8
-
-
... More
Providing and laying plain cement concrete 1:3:6 (1-Cement: 3- coarse sand: 6- hand broken stone aggregates 40 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth as directed by engineer-in-charge.
7.9
-
-
... More
Construction of un-reinforced, dowel jointed, plain cement concrete pavement(concrete Grade M-40) over a prepared sub base with 53 grade cement @ 440 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a slip form paver with electronic sensor, spread, compacted and finished in a continuous operation including cost of contraction, expansion, construction and longitudinal joints, joint filler, 200 micron separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rods, admixtures as approved, curing compound, finishing to lines and grades as per drawing and as directed by engineer-in-charge.
6567
-
-
... More
Providing and laying controlled cement concrete work M250 and curing complete including scaffolding centering, formwork, needle vibrated consolidation, curing complete up to 6 meter depth or height (excluding cost of reinforcement and neat finishing) with centering and shuttering/deshuttering etc. complete for structure other than water retaining
201
-
-
... More
Supply of factory-made Precast Box Culvert units of required size. Product should be confirming to IS Requirements, made by using advanced precast technology having High Performance Self Compacting Concrete of M-50-cylinder strength using Fe500D with factory made epoxy reinforcement bar. The Precast Box culvert should have special provisions at appropriate location for mechanical installation. The Rate are included all kinds of Material, joining bolts, labour and Transportation factory to site of work and Taxation charges except site unloading and installation. Approved make for Precast Box culvert.
-
-
-
... More
a) 0.6 m X 0.6 m (In to In)
24
-
-
... More
c) 1.2 m X 1.2 m (In to In)
605
-
-
... More
b) 0.90 m X 0.90 m (In to In)
650
-
-
... More
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:6 (1‐ Cement : 6 ‐fine sand)(B) Conventional (upto 10 ton) extra for brickwork in superstructure above floor to level.
702.72
-
-
... More
Design, Manufacture & Supply of approved make factory-made (wet cast) Precast Drain of various sizes as mentioned below (W X D X L). Precast concrete Drain made up of high strength precast reinforced cement concrete duly steam cured in a controlled environment and manufactured by using high performance self-compacting concrete of M- 50 grade using Fe 500D grade TMT steel reinforcement bar. The product shall be designed to take 1.8 T wheel loading on top and 25 T uniformly distributed loading on its side wall. The product should have flange coupling jointing arrangements, one each at bottom and both the side walls, at appropriate location for shear connection between two products. These are to be tightened up with nut-bolt. Concrete and Reinforcement design shall confirm IS 456:2000 furthermore taking into consideration expected handling and erection stresses etc. Any international guideline such as AASHTO, FHWA (Accelerated Bridge Construction Guidelines) Japan and EURO codes may be followed. It shall be designed for 10 T Axle Load - 5 T Wheel Load. Make Approved by GIDC.
-
-
-
... More
External wall & RCC surface painting 2 coats of putty +2 coats of primer + two coats of APEX or equivalent paint) with APEX exterior paint of Asian paints of required shade or equivalent (100 Percentage acrylic paint) including a priming coat of external primer of approved brand and manufacture on wall & any other surfaces to give an even shade after thoroughly brushing the surface & making the surface free from mortar droppings and other foreign matter and sand papered smooth incl. filling the all small holes, cracks, open joints, undulations and similar other minor defects of every kind with Birla white putty or equivalent putty and rubbed smooth with sand paper incl. necessary scaffoldings etc. complete at all height as directed by engineer-in-charge.
470
-
-
... More
Earth work for subgrade of min. 500 mm thick having CBR not less than 8 Percentage using yellow earth brought from outside with all lead & lift having PI value less than 15 including breaking clods dressing with all lead and lift and including watering rolling and consolidation of sub grade in layers not exceeding 200 mm thickness at O.M.C to required dry density including filling the depressions which occur during the process using power roller 8 to 10 tonne as directed by engineer-in-charge.
45945.31
-
-
... More
b) 0.80 m X 0.90 m (In to In)
1028
-
-
... More
Lowering, Laying & Installation of factory-made Precast Box Culvert units of required size.
-
-
-
... More
b) 0.90 m X 0.90 m (In to In)
650
-
-
... More
Providing and casting in situ-controlled cement concrete M-200 for kerb including formwork, curing & finishing kerb stone laid with kerb laying machine, foundation concrete (PCC-M10) laid manually, etc. all complete as directed by engineer-in-charge. (Kerb size 30 cm Ht & 30 Cm Length).
105.98
-
-
... More
Providing and laying controlled cement concrete work M250 and curing complete including scaffolding centering, formwork, needle vibrated consolidation, curing complete as per drawing (excluding cost of reinforcement) incl. formwork, centering and shuttering/de-shuttering etc. complete at all height & directed by engineer-in-charge. (For Columns, pillars post and struts).
20
-
-
... More
Providing TMT Fe 500-D with factory made Epoxy bar reinforcement (I.S. Mark) for RCC work including bending, binding and placing in position complete up to floor two level as directed by engineer-in-charge.
18390
-
-
... More
Providing fusion bonded Epoxy coating not less than 175 micron thickness and up to 300 micron to reinforcement bars as per IS-13620-1993/ASTM-775 M including testing of coating at plant and all taxes (A) 10mm to 16mm dia bar
82168
-
-
... More
Informatory sign boards providing & fixing sign boards made out of 2 mm aluminium sheet size 80 x 60 cms. rectangle as per the design of IRC-67-1977 Pre-treated with phosphating process & acid etching; coated with one coat of epoxy primer and two coats of best quality epoxy paint reflectorised with retro reflective sheeting as per latest M.O.S.T. Specifications: 3.1 mt long stand post and frame fabricated from suitable size iron angle of 35x35x3 mm .75x75x6 mm as required; paint with best quality epoxy coating in black and white bends. The details of symbol for each board shall be as per the instruction of of Contractor engineer in charge. The fixing at site shall be in 1:2:4 CC blocks of size 45 x 45 x 60 cms. For each leg. Including excavation curing etc. complete under the supervision of engineer.
20
-
-
... More
C) 1.2m X 1.2m (In to IN)
605
-
-
... More
a) 0.6 m X 0.6 m (In to In)
40
-
-
... More
Design, Manufacture & Supply of approved make factory-made (wet cast) Precast Lid Covers suitable for placing on SWD Elements (15 mm drop to place on Drain),of Width and Depth as given in table. The product should be meeting BIS requirements and confirming to Japanese Industrial Standards (JIS). The product shall be duly steam cured in the plant to have requisite compressive strength and having load carrying capacity of 1.8 Tonnes wheel load. The product shall be made by using advanced precast technology using high performance self-compacting concrete of M 50 grade and Fe 500 D grade TMT steel reinforcement bar. The product shall have in built insert at optimized locations for mechanical installation activities including supply and transportation at site. Precast Lid element should have embossed GIDC logo (as approved by competent authority) on top side etc. complete as per instruction of engineer in charge.
-
-
-