Defence Research And Development Organisation Tender

... More
The DRDO has issued a formal invitation for competitive bids for the Defence Research And Development Organisation project, for Provision Of Security Perimeter Wall,watch Towers And Perimeter Patrol Road For Lrde Test Site O in Devbhumi Dwarka, Gujarat, with an estimated contract value of Rs. 25,91,41,298. The bid opening date for this tender is 31-10-2026 and the last date for bid submission is 25-11-2026. Interested bidders for Defence Research And Development Organisation tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Defence Research And Development Organisation - DRDO Tender - Gujarat Tender

Opening Date31 Oct 2026
Closing Date25 Nov 2026
Tender Amount₹ 25,91,41,298.07 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Provision Of Security Perimeter Wall,watch Towers And Perimeter Patrol Road For Lrde Test Site O

AI Insights

Unlock AI Insights for this Tender

Sign in to request AI-powered insights, eligibility criteria and automated analysis for this tender.

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
lift upto 1.5 m

2483

276

685308

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. Note : No additional payment will be made for extra lift for mechanical Excavation

-

-

-

... More
Ordinary rock

-

-

-

... More
lift upto 1.5 m

2168

607

1315976

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.

-

-

-

... More
All kinds of soil.

32062

214

6861268

... More
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials.( For manual means)

100

57

5700

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed.

-

-

-

... More
Ordinary rock

3639

424

1542936

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

10141

191

1936931

... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation, road etc. complete for all lifts.

500

895

447500

... More
Supplying and stacking of hard stone (for stone pitching) 22.5 cm thick at site.

100

969

96900

... More
Dry stone pitching 22.5 cm thick laid in courses and required profile with hammer dressed stones having no side less than 15 cm, with minimum depth of 20 cm including preparing the bedding surface etc. all complete. (Payment for Stone to be made separately )

109

641

69869

... More
Providing and laying 120 GSM non-woven, needle-punched polypropylene geotextile fabric beneath the HDPE pond liner over a properly prepared, levelled and compacted subgrade, including cutting, laying, jointing with adequate overlaps and dressing to the pond bed and side slopes, complete as per manufacturer's recommendations and the directions of the Engineer-in-Charge.

12100

90

1089000

... More
SUB HEAD - II : ANTI-TERMITE TREATMENT

-

-

-

... More
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%

47

249

11703

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)

-

-

-

... More
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.

268

36

9648

... More
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.

-

-

-

... More
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor :

366

205

75030

... More
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.

-

-

-

... More
SUB HEAD - IIII : PLAIN & REINFORCED CONCRETE

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:

-

-

-

... More
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

925

6612

6116100

... More
1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size).

8

7144

57152

... More
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).

5

8130

40650

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, sulphate resistant cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
All work upto plinth level

-

-

-

... More
Concrete of M35 grade with minimum cement content of 370 kg/cum

2690

9542

25667980

... More
All work above plinth level upto floor V level

-

-

-

... More
Concrete of M35 grade with minimum cement content of 370 kg/cum

643

9888

6357984

... More
Add for using extra cement in the items of design mix over and above the specified cement content therein.

1300

1065

1384500

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at plinth level and above plinth level at all heights.

-

-

-

... More
Grade Fe-500D CRS (Corrosive Resistance Steel) confirming to IS 1786-2008 or more.

364387

120

44003374.12

... More
Providing, fixing and stripping off all types of shuttering for all RCC works at all depths and heights complete as per drawings, specifications and instructions of the Engineer.

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

6846

283

1937418

... More
Suspended floors, Roofs, landings, balconies and access platform

1110

674

748140

... More
Lintels, beams, Plinth beams, girders, bressumers and cantilevers

3687

542

1998354

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

4111

718

2951698

... More
Weather shade, Chajjas, corbels etc., including edges

136

768

104448

... More
Stairs, (excluding landings) except spiral-staircases

281

744

209064

... More
e) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

5041

820

4133620

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of Stone aggregate 40 mm nominal size, well rammed and consolidated and grouted with fine sand including finishing the top smooth.

787

676

532012

... More
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-35 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).

-

-

-

... More
Note: Truck Mounted rotary/ TMR/ Tube well boring machine shall not be used.

-

-

-

... More
600 mm dia piles

1840

5241

9643440

... More
Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge.

245

1122

274890

... More
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.

-

-

-

... More
Single pile upto 50 tonne Safe capacity

-

-

-

... More
Initial test (Test Load 2.5 times the Safe capacity)

2

53293

106586

... More
Routine test (Test Load 1.5 times the Safe capacity)

2

19102

38204

... More
Lateral load testing of single pile in accordance with IS Code of practice IS : 2911 (Part IV) for determining safe allowable lateral load on pile :

-

-

-

... More
Upto 50 tonne capacity pile

1

19102

19102

... More
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).

23

10078

231794

... More
SUB HEAD - IV: STONE & BRICK MASONRY

-

-

-

... More
Providing random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level including cost of bond stones as required with :

-

-

-

... More
Cement mortar 1:6 (1 cement : 6 coarse sand)

10

7480

74800

... More
Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Including cost of bond stones as required.

-

-

-

... More
Cement mortar 1:6 (1 cement : 6 coarse sand)

15

8494

127410

... More
Providing and fixing up to plinth level level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).

10

8491

84910

... More
Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).

763

14229

10856727

... More
SUB HEAD - V: FINISHING

-

-

-

... More
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. (No extra items shall be paid on acount of sand faced plaster)

2353

441

1037673

... More
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

232

55

12760

... More
Extra for addition of synthetic Polyester triangular fibre of length 6 mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement plaster/mortar by using 125 gms. of synthetic Polyester triangular fibre for 50 Kgs. cement used in cement mortar as per directions of Engineer-in-Charge.

37

71

2627

... More
Providing internal cement plaster 12 mm thk. in single coat in cement mortar 1:6 (1 cement: 6 fine sand) to concrete or brick surfaces in all positions including scaffolding and curing complete.

16560

278

4603680

... More
Providing internal cement plaster 6 mm thk. in single coat in cement mortar 1:3 (1 cement: 3 fine sand) to concrete surface in all positions including scaffolding, curing complete.

94

240

22560

... More
Finishing walls with Acrylic Smooth exterior paint of required shade :

-

-

-

... More
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). ( No extra items shall be paid on acount of sand faced plaster)

2450

155

379750

... More
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand)

1734

427

740418

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :

-

-

-

... More
New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre

1734

163

282642

... More
Providing and fixing GI plaster mesh of nominal thickness 0.35 to 0.40 mm with zinc coating of 120 gms per sqm of approved make all as directed.

418

110

45980

... More
Finishing walls with water proofing cement paint of required shade :

16560

114

1887840

... More
New work (Two or more coats applied @ 3.84 kg/10 sqm)

-

-

-

... More
Applying priming coat :

-

-

-

... More
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works

1081

66

71346

... More
Applying priming coat : With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood

-

-

-

... More
Two or more coats on new work.

135

73

9855

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :

-

-

-

... More
Two or more coats on new work.

135

152

20520

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.

-

-

-

... More
On steel work

1201

235

282235

... More
SUB HEAD - VI : FLOORING

-

-

-

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand).

221

1828

403988

... More
25 mm thick.

-

-

-

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

52

2216

115232

... More
Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.5 metre .

274

31

8494

... More
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.

375

160

60000

... More
Providing and laying Ceramic glazed anti skid floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.

59

1153

68027

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

169

1236

208884

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.

-

-

-

... More
Size of Tile 600x600 mm

298

1580

470840

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.

45

1604

72180

... More
Size of Tile 600x600 mm

-

-

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.

9

598

5382

... More
40mm thick with 20mm nominal size stone aggregate.

-

-

-

... More
Cement plaster skirting (up to 30 cm height) with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement.

2

644

1288

... More
18 mm thick.

-

-

-

... More
SUBHEAD VII : DOOR & WINDOW WORK

-

-

-

... More
a) Providing and fixing to existing door frames.

-

-

-

... More
30mm thick Glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.complete as as per direction of Engineer-in-charge.

130

5092

661960

... More
Providing and fixing Fibre Glass Reinforced Plastic (FRP) Door Frames of cross section 90mm x 45mm having single rebate of 32mm x 15mm to receive shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibre glass from all sides. M.S. stay shall be provided at the bottom to steady the frame, complete as as per direction of Engineer-in-charge.

43

1144

49192

... More
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :

-

-

-

... More
Size 150x10 mm

26

112

2912

... More
200 x 10mm

70

172

12040

... More
Providing and fixing aluminium extruded section body tubular type Universal Hydraulic Door Closure (having brand logo with ISI, IS:3564. embossed on the body, door weight up to 36 kg to 80 kg and door width from 701mm to 1000mm) with double speed adjustment with necessary accessories and screws etc. complete

8

1426

11408

... More
Providing and fixing Aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868); transparent or dyed to required colour or shade, with necessary screws etc. complete:

-

-

-

... More
100mm long

52

95

4940

... More
125mm

70

130

9100

... More
Providing and fixing Aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868); transparent or dyed to required colour or shade with nuts and screws etc. complete:

-

-

-

... More
300 x 16mm

21

425

8925

... More
250x16 mm

50

370

18500

... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper

70

39

2730

... More
Providing and fixing IS:12817 marked Stainless Steel Butt hinges with stainless steel screws etc. complete

-

-

-

... More
100 mm x 58mm x 1.90mm

78

98

7644

... More
125 mm x 64 mm x 1.90 mm

105

140

14700

... More
Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles with necessary screws etc. complete. (Best make of approved quality).

9

1406

12654

... More
Filling the gap in between UPVC/ aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5mm width

384

89

34176

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :

-

-

-

... More
For Fixed Portion

1033

611

631163

... More
Powder coated aluminum (minimum thickness of powder coating 50 micron)

-

-

-

... More
For shutters of doors, windows & Ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)

-

-

-

... More
Powder coated aluminum (minimum thickness of powder coating 50 micron)

1414

689

974246

... More
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):

-

-

-

... More
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)

152

1520

231040

... More
Deduct for providing pin headed glass panes instead of ordinary float glass panes weighing 5 mm thick (weight not less than 12.50 kg/sqm) in doors, windows and clerestory windows shutters (Area of opening for glass panes excluding portion inside rebate shall be measured).

15

-72

-1080

... More
fly proof stainless steel grade 304 wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm

106

1481

156986

... More
Providing and fixing 12 mm thick marine plywood conforming to IS 710, of approved make and grade, for panelling in aluminium door shutters, window shutters and partition frames, finished with approved decorative laminate on one face and balancing laminate on the reverse face, including cutting, fitting, sealing of all exposed edges and drilled holes with compatible moisture-resistant sealant, and fixing with SS 316 stainless steel screws and necessary accessories, complete as per architectural drawings and directions of the Engineer-in-Charge.

67

1282

85894

... More
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).

1394

566

789004

... More
SUB HEAD - VIII : ROOFING & MISC WORKS

-

-

-

... More
Terrace Waterproofing

489

2609

1275801

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:

-

-

-

... More
a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.

-

-

-

... More
b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.

-

-

-

... More
c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.

-

-

-

... More
d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.

-

-

-

... More
e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :

-

-

-

... More
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.

-

-

-

... More
Providing and laying on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. Rain Water Pipes 110 mm diameter

80

406

32480

... More
SUB HEAD - IX : STEEL WORK

-

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.

40023

168

6723864

... More
in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

-

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

3499

752

2631248

... More
Providing and fixing concertina coil fencing with punched S.S concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal S.S barbed wire, stud tied with S.S staples and S.S clips to retain horizontal, including necessary bolts or S.S barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced S.S barbed / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 166.67 gm/ metre (cost of S.S. angle, C.C. blocks shall be paid separately)

7026

1400

9836400

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.

1360

1118

1520480

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes

1620

189

306180

... More
SUB HEAD - X : SANITARY SERVICES

-

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests .

10

6585

65850

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap.

10

1828

18280

... More
Providing and fixing wall-mounted three-hole wall mixer with provision for overhead shower, having two separate handles for hot and cold water control, central diverter, overhead shower arm with wall flange and shower head, bath spout with water outlet, connecting legs, wall flanges and all necessary CP brass fittings, with chromium-plated finish, suitable for hot and cold water supply, including all required connections, seals and accessories, complete as per the manufacturer's specifications and directions of the Engineer-in-Charge.

8

6753

54024

... More
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :

8

216

1728

... More
150 mm diameter

-

-

-

... More
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :

2

8194

16388

... More
Supplying & Fixing of CP liquid soap container of pump type with initial soap fill all hardwares etc complete. Make & Model as approved by Engineer-In-Charge.

10

1617

16170

... More
Supplying & Fixing of CP Towel Ring with flange & all hardwares etc complete.

10

814

8140

... More
Providing and fixing 15 mm nominal bore C.P. brass short body bib cock of approved quality conforming to IS : 8931.Make & Model as approved by Engineer - in -charge.

10

1607

16070

... More
Providing and fixing approved type SS coat hooks with concealed type screws of approved make.

10

799

7990

... More
All WCs

-

-

-

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 1 15 mm nominal bore

34

777

26418

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.

-

-

-

... More
Semi rigid pipe

-

-

-

... More
32 mm dia

10

101

1010

... More
Supplying & laying PVC Pipes conforming to I.S - 13592 type B including necessary fittings and joining with rubber rings and lubricants as per standard practice with holder bats; PVC clamps, bends, tees, clean outs, vent cowls, dash fasteners fixed to walls,beams, or ceiling as required slope, pcc bedding and necessary special heavy detachable MS bracket and Testing as per standard Practice

-

-

-

... More
Soil, Waste & Vent Pipes

-

-

-

... More
110 mm dia pipe.

100

715

71500

... More
75 mm dia pipe.

100

541

54100

... More
Providing and fixing PVC Nahani / Multi Trap withwith Square SS jali with Frame

-

-

-

... More
75 X 75 mm dia Size

18

1325

23850

... More
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore

10

95

950

... More
SUB HEAD - XI : INTERNAL WATER SUPPLY

-

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes SDR 11/ SCH40, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge.

-

-

-

... More
Internal work - Exposed on wall

-

-

-

... More
20 mm dia nominal bore

90

725

65250

... More
25 mm dia nominal bore

40

802

32080

... More
32 mm nominal outer dia Pipes

80

992

79360

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, i/c fixing the pipe with clampsat 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Concealed work, including cutting chases and making good the walls etc.

-

-

-

... More
15 mm dia nominal outer dia pipe

180

366

65880

... More
20 mm nominal outer dia Pipes

100

430

43000

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
32 mm nominal bore

8

2546

20368

... More
Providing and fixing Ball valve (bronze) of approved quality, High or low pressure complete as directed.

-

-

-

... More
20 mm nominal bore

8

1036

8288

... More
25 mm nominal bore

8

1453

11624

... More
SUB HEAD-XII : EXTERNAL WATER SUPPLY

-

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
32 mm nominal outer dia Pipes

400

1207

482800

... More
50 mm nominal inner dia Pipes

400

1810

724000

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

9000

10

96300

... More
Supply and installation of 500 Microns (0.50 mm) High-Density Polyethylene (HDPE) Geomembrane Liner for agricultural farm ponds (shet tale), strictly complying with IS 15351:2015 (Type II) standards and bearing the mandatory ISI mark. The liner must be manufactured from 100% virgin resin material with a minimum weight of 420 GSM, featuring a 2.0% to 3.0% carbon black dispersion for superior UV stabilization against prolonged outdoor weather exposure. The material must be multi-layered, free from recycled fillers, and offer a minimum tensile breaking strength of 110 KGF across both axes to resist environmental stress cracking and subsurface punctures. Field joints and seams must be executed exclusively using heavy-duty, dual-track hot-wedge thermal fusion welding to ensure a completely leak-proof system, with the final installation securely anchored into peripheral trenches as per standardized irrigation engineering designs.

12100

164

1984400

... More
SUB HEAD - XIII : EXTERNAL SEWAGE DISPOSAL

-

-

-

... More
Supplying & fixing uPVC Pipes conforming to I.S - 15328 & providing Nominal ring stiffness of SN 4 kn/m sq including necessary fittings and joining with rubber rings and solvents as per standard practice laid to required alignment and slopes in excavated trenches.

-

-

-

... More
110 mm diameter (SN 8)

180

1145

206100

... More
160 mm diameter (SN 4)

90

1401

126090

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing / refilling of surplus excavated soil as directed, within a lead of 50 m :

-

-

-

... More
All kinds of soil

-

-

-

... More
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

270

312

84240

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :

-

-

-

... More
110 mm diameter

180

410

73800

... More
160 mm diameter

90

665

59850

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:

-

-

-

... More
100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

10

2635

26350

... More
Constructing brick masonary chamber ,With Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.

10

6751

67510

... More
Supply, lowering & installation of RCC readymade humepipe septic tank at suitable location including earth work excvation in all types of soil, necessary pcc bedding as directed including sewerline connections at inlet & outlet, Inspection Chambers etc., complete as per standard design & as directed.

-

-

-

... More
Inlet & Outlets - 100mm

-

-

-

... More
Wall Thickness minimum 50mm

-

-

-

... More
2 nos of Manholes including Extension of Manhole up to ground level with brickwork, plaster and cover on top

-

-

-

... More
25 User Capacity

10

33140

331400

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

10

26136

261360

... More
SUB HEAD - XIV : ROAD WORK

-

-

-

... More
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge

-

-

-

... More
With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25

2395

2845

6813775

... More
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.

2206

2836

6256216

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.

19745

213

4205685

... More
Providing and laying Separation Membranee impermeable PVC sheet 125 micron thick transparent or white in colour. laid flat with minimum creases.Before placing the separation membrane, the sub-base shall be swept clean of all the extraneous materials using air compressor. Overlap of at least 300 mm is to be provided. etc complete as directed by engineer in charge

13863

140

1940820

... More
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,inishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note .Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately

-

-

-

... More
Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer

1890

10799

20410110

... More
Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.

10923

5

54615

... More
Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints/ contraction in roads / pavements all complete as per direction of the Engineer-in-Charge.

94523

8

756184

... More
Using grade 'A' sealing compound conforming to IS: 1834.

-

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :

-

-

-

... More
a) 150mm dia

150

541

81150

... More
b) 300mm dia

100

967

96700

... More
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete

-

-

-

... More
a) 450mm dia

150

2604

390600

... More
b) 600 mm dia

100

3309

330900

... More
c) 900 mm dia

110

5232

575520

... More
SUB HEAD XV : INTERNAL ELECTRIFICATION & POWER WIRING

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
(a) One light/fan point controlled by one 6A switch.(Group A)

112

1189

133168

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.

24

1803

43272

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

16

373

5968

... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

1120

267

299040

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

160

311

49760

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

640

373

238720

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

80

47

3760

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

112

545

61040

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

16

659

10544

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

64

104

6656

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.

16

112

1792

... More
LIGHT FIXTURES

-

-

-

... More
LED Batten light (System lumen efficacy ≥105 <120lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light (18-22 Watt) of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation

32

721

23072

... More
Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing / Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)

-

-

-

... More
18-22 Watt

-

-

-

... More
Supplying and erecting 18-20W, LED surface mounted light fitting with extuded aluminium body & plastic end caps Luminaire Efficacy- 100 lm/W Lumen Flux- 2000 lm Color Rendering Index- >80 Built-in Surge protection- 3 Kv with all fixing accessories.

10

493

4935

... More
LED Flood Light, powder coated pressure die <135 lm/Watt). Supplying, Installation, Testing & Commissioning of 70 Watt Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range - 5 0 C to 50 0 C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3- -66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5 ,

48

2299

110352

... More
Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 yea r <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)

-

-

-

... More
BLDC FAN

-

-

-

... More
Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 0 C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.

-

-

-

... More
1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)

27

2695

72765

... More
Supply, Installation, testing & commissioning of Exhaust fans of 305mm size sweep with gravity louvers shutters including making appropriate size of hole finish in shape and other civil engineering works make them good after installation, 3C x 1.5sqmm flexible cable from ceiling rose up to fan and all fixing accessories/ hardware of materials as required. (Make : Orient/ equivalent)

8

4646

37171.2

... More
MCCB, MCB & DB'S

-

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
4 way (4 + 12), Double door

67

7951

532717

... More
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

8

472

3776

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

40

14

560

... More
Supplying and fixing following rating, double pole, 240 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. As required.

-

-

-

... More
10 AMP

64

472

30208

... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

16

1806

28896

... More
CABLE TRAYS

-

-

-

... More
Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

40

686

27440

... More
300 mm width X 62.5 mm depth X 2.0 mm thickness

80

1025

82000

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

40

1348

53920

... More
Providing and fixing standard size ISI certified Electrical storage water heater with rated wattage 2kw, 230V,50Hz,Single Phase, 1/2 inch inlet outlet connection, SS tank and 4 star energy rating with thermostat feature, Glass lined inner tank and heating element with safety valve etc complete including angle stop cock and all the items metioned as below.

-

-

-

... More
25 Ltrs capacity

8

18541

148328

... More
Supply, installation, testing and commissioning of aquaguard purechill RO storage cooler cum purifier with its one of akind purification technolodgy (RO) with cooling and storage solution of following specification: (a) Aproxx external dimension (W x D x H) 640x450x1350 mm operating power supply 230 V AC 50 HZ (b) Filter cartridges sediment activated carbon block running current in 4.5 amp. (c) power in watt 700W. (d) Water storage tank capacity with comfort Level Water outlet tempreture at 17 degree celcues 60 litre. compressor make copeland or each tecumesh refrigerant freon 22 stages details 1. Particular filter. 2. Prte carbon block filter. 3. Anti scalant filter. 4. Sediment filter. 5. reverse osmosis membrane filter. 6. post cabon block filter. 7. nano silver launching filter. 8. RO membrane rating 4 nos x 75 GDP or equivalent make kent / Eureka forces or equavalent.

8

67589

540712

... More
SUB HEAD XVI : TELEPHONE

-

-

-

... More
Supplyiing, installation, testing and Commissioning of IP at its core with IP switching technology and 100% non blocking communication system with 04 Port Voicemail, 04 Port FXS, 04 Port FXO, 1 PRI Trunk lines (30 Channels) Circuit with CLIP Facility, min 100 IP users License with provision for further additions, 100 analog users, 01 Number IP based Operator Console, 45 Party Conference, Speed Dial, Music on Hold, Internal/ External ring difference, Call Barring, Call Pickup. The system should be redundant which offer 100% duplication of power supply and CPU card and to match the hybrid IP-PBX as per technical specification including supporting accessories etc complete as required. The system should have valid TEC GR approval from DoT.

2

1246949

2493898

... More
Supply, Installation, testing & commissioning of Rack Mountable Media Gateway equipped with 24 Nos. Analogue, 12 IP Extention, 6 Nos Analogue Trunks & 01 Nos. PRI, exchange shall have Redundancy - Hot standby, Hot swappable, duplicate control cards and duplicated power supply unit, no single point of failure and no dropping of established calls even during changes over of duplicate cards . cost shall have include with required license, software , associates card & Cable as per specification.

1

527670

527670

... More
Supplying, Installation, Testing & Commissioning of Analog phones having standard feautres like 16 digit LCD display, 2 way speaker, caller ID and number storage facility etc. complete as required.

18

1544

27792

... More
Supplying, Installation, Testing & Commissioning of Type 1 IP Phone having 2 VoIP account, 120 x40 DOT matrix screen with backlight, Full HD duplex speaker phone, IPV6, Gigabit Etherent, PoE etc. complete as required.

2

11689

23378

... More
Supply and laying of 20 pair armoured 0.5mm dia Jelly filled copper conducter armoured cables in vertical shapt/ cable tray in ceiling as required and as directed by Engr-in-charge. The cable shall be as per the DOT specifications.

120

278

33360

... More
Supply and laying of 20 pair armoured 0.5mm dia Jelly filled copper conducter armoured cables in ground at 750mm below ground level including excavation, and refilling of earth, laying and jointing of cables, providing protection with bricks on top and sides and teliphone cable route markers at every 50 meters interval complete as required and as directed by Engr-in-charge. The cable shall be as per the DOT specifications.

4600

585

2691000

... More
Supplying and fixing of following sizes of heavy duty 2mm thick PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

50

168

8400

120

209

25080

... More
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.

-

-

-

... More
75 mm X 75 mm X 60 mm deep

18

213

3834

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
Telephone socket outlet (RJ-11)

18

168

3024

... More
SUBHEAD - XVII - EARTHING

-

-

-

... More
EARTHING AS PER IEC 62561- 2 & 7

-

-

-

... More
Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 185 sq. Mm

37

2117

78329

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. (but without charcoal/ coke and salt) as required.

4

13733

54932

... More
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. As required.

100

2245

224500

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.

37

8351

308987

... More
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.

145

221

32045

... More
SUBHEAD - XXII - LIGHTNING PROTECTION

-

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. Base plate including holes etc. complete as required.

8

609

4872

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)

40

148

5920

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)

80

238

19040

... More
Supply & Installation of Parapet Conductor holder for holding of 8 mm dia. round conductor (for RCC roof). The conductor holder shall be mounted on plastic base support and shall meet the requirements of IEC 62561-4.It should be installed at every 1 mtr.

120

100

12000

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

8

140

1120

... More
EARTHING AS PER IEC 62561- 2 & 7

-

-

-

... More
Supply and installation of long life Maintenance Free Earthing System . The Rod shall be of Copper Bonded Steel with 23.2 mm dia. and 10 feet length with a core of mild steel molecularly bonded with min. 250 microns coating of 99.99% pure electrolytic grade Copper and exothermically welded Cu Busbar of 50X6X200mm both tested by CPRI capable of bearing fault current of 35kA. Along with earth enhance compound tested by RoHs complying IEC 62561-7 in a sealed bag of minimum 50 kg (25 kg Bag x 2) resistivity is less than 0.2 ohm meter. The earthing shall be with Suitable Poly-plastic Pit Cover with lockable arrangement.

8

7626

61008

... More
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.

40

221

8840

... More
SUB HEAD XVIII : STREET LIGHTING/AREA LIGHTING

-

-

-

... More
Supply of solar internal AIO (All in One) street light with high pressure die-cast (LM6 Alloy) Aluminium housing, reliable and robust construction with IP65 & IK08 protection,suitable for OD 50/60 mm bracket,PCC Pole 8.5 mtr Long (LT) including civil works having Min 4500 system Lumens, suitable for 24 hrs (2 Nights) Autonomy. The luminaire should work on Hybrid mode with priority for solar, in case solar charging is not available then it should automatically switch to AC grid supply for reliable operation. Dimming profile: From Dusk - First 4 hours full brightness level. Next fixed at 30 % Brightness level. Lithium Pherrophosphate Battery capacity Min 30 Ah@12.8V or 256 Wh & Battery Temp range - 10 to +50 C. Panel capacity min 60Wp, CRI >=70. System Efficacy > 150lm/W, & System wattage should noy be more than 2 X 30W+ 2% Luminare, (double Arms) if wattages increases then the size of battery and panel shall also be increased in similar percentage to maintain equal autonomy of the system. The fixture should have designed for street light application & should have flexible angle of mounting from 0-15 Degree for divers geographical condition. Life class of LED System 50000hrs @ L70. LED Make: CREE/NICHIA/LUMILEDS/OSRAM/PHILIPS/BAJAJ.CE Certified. Charger efficiency >90% . Standards IEC62109-1,IEC61547, CISPR15, IEC62093, IEC61347-2-13, EN50530, IEC62384 or equivalent BIS Stanhe PV module should be made up of crystallin silicon solar cells "Mono-Crystallin" and must have a certificate of testing confirming to IEC61215 Edition II / BIS 14286 & IEC 61730-1, 2 IEC60598. Notes Rate consider for 1 No PCC pole & 2 Nos Solar Hybrid Luminare.

150

75381

11307150

... More
Suppy, laying and commissioning of 4C X 16sq 1.1 KV grade XLPE insulated armoured aluminium conductor underground cable, in built up cable trench / already laid in RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protectin with sand and bricks at sides and top and cable route markers at every 15 mtr interval and also at the turnings. The cable shall conform to IS.

5500

572

3146000

... More
Supplying and making end termination with brass compression gland and aluminium lugs for 3 x 10 Sqmm (22mm) XLPE aluminium conductor cable of 1.1 KV grade as required.

150

257

38550

... More
Proving Spiral coil earthing with 8SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments.(150/4=40 appx)

150

1920

288000

... More
Supply, eraction and commissioning of individual Gate lights with 0.6 mtr long 65 mm dia class B GI pole complete with base plate FRP terminal box to the fixture with 3 core 2.5 Sq.mm copper wire, MCB control and 50mm dia class B GI pipe & 25 mm dia PVC pipe for incoming and outgoing cables etc. and supply and installation of 50W LED Lamp post top Lantern integral type with control gear and fixing accesories complete as required.

10

15967

159670

... More
Supply, eraction and commissioning of 300 Watt LED security search light with motorized syestem- High intensity, long range, weather and dust proof motor operated security search light with highly polished stainless steel reflector cum body. Suitable heat sinks, toughened from glass, retaining ring MS Cradle and passivated bolts. The search light would be supplied with 415V, 150 W LED COB Lamp & its electronic driver in cast aluminium housing. The search light fitting would be suitable for installing on the roof of the watch tower cabin. The search light would be swiveling type & have both vertical & horizontal operational controls with the help of remote control unit with suitable control cable.

8

189139

1513112

... More
SUB HEAD XIX : EXTERNAL ELECTRIFICATION

-

-

-

... More
LT PANEL

-

-

-

... More
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 14 SWG MS sheet after seven tank process and painting with Epoxy powder coating. The panel shall consist of IP54 rating, TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below. The Panel shall be tested/ verified by OEM and complying to latest IEC standards of 61439. The PCC shall have at least two spare cubicles of the maximum rating. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. For all incomers and outgoings Digital Ammeter with resign cast CTs and selector switches shall be provided.

1

428779

428779

... More
All Incomer Shall have TVSS Protection of CL-2

-

-

-

... More
INCOMER

-

-

-

... More
1 No.200 Amp 415 volt grade, 36kA 4P MCCB each complete with Microprocessor release having inbuilt overload protection with time delay, short circuit protection with time delay and instantaneous along with earth fault protection. 230 V AC spring charging motor and closing coil. Shunt trip coil 24 V DC and under voltage coil 230 V AC. Safety shutter & 6 NO + 6 NC contacts. 3 nos cast resin current transformer of 200/5 ratio class 1.0 for metering, 15 VA Burden. Multifunction meter communication Port RS-485 with 1 set of three RYB indicating lamps. Red/green/amber ON/OFF/Trip indicating lamps. Spring charge indication lamp. Breaker control switch. 1 Set PT 415/root3V/110/root3 V; 100 VA; class 1.0 Under voltage relay (27)-415 VAC. Over voltage relay (59)-415 V AC Illuminated push button for healthy circuit.

-

-

-

... More
BUSBARS TPN aluminium bus bars of minimum 250 Amps capacity with heat shrinkable coloured sleeves and i/c, SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 36KA for 1 sec.

-

-

-

... More
OUTGOING

-

-

-

... More
100A FP MCCB, 25kA - 5NO

-

-

-

... More
63A FP MCCB, 25kA- 3NO

-

-

-

... More
32A FP 16KA T&M based MCB -3NO

-

-

-

-

-

-

... More
panel shall be type-tested assembly (TTA) compliant with IEC 61439,

-

-

-

... More
All outgoing MCCBs shall be MP based with adjustable and inbuilt O/L & S/C protection

-

-

-

... More
All breakers breaking capacities shall be Icu=Ics upto 433 V.

-

-

-

... More
1 Set Rotary operating mechanism and terminal extension spreaders for all the MCCBs. ON/OFF/TRIP indicating LED lamps each with 2 amp back up MCB.

-

-

-

... More
ALL Outgoing shall have Multifunction Meter

-

-

-

... More
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 14 SWG MS sheet after seven tank process and painting with Epoxy powder coating. The panel shall consist of IP54 rating, TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below. The Panel shall be tested/ verified by OEM and complying to latest IEC standards of 61439. The PCC shall have at least two spare cubicles of the maximum rating. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. For all incomers and outgoings Digital Ammeter with resign cast CTs and selector switches shall be provided.

1

358285

358285

... More
All Incomer Shall have TVSS Protection of CL-2

-

-

-

... More
INCOMER

-

-

-

... More
1 No.150 Amp 415 volt grade, 36kA 4P MCCB each complete with Microprocessor release having inbuilt overload protection with time delay, short circuit protection with time delay and instantaneous along with earth fault protection. 230 V AC spring charging motor and closing coil. Shunt trip coil 24 V DC and under voltage coil 230 V AC. Safety shutter & 6 NO + 6 NC contacts. 3 nos cast resin current transformer of 200/5 ratio class 1.0 for metering, 15 VA Burden. Multifunction meter communication Port RS-485 with 1 set of three RYB indicating lamps. Red/green/amber ON/OFF/Trip indicating lamps. Spring charge indication lamp. Breaker control switch. 1 Set PT 415/root3V/110/root3 V; 100 VA; class 1.0 Under voltage relay (27)-415 VAC. Over voltage relay (59)-415 V AC Illuminated push button for healthy circuit.

-

-

-

... More
BUSBARS TPN aluminium bus bars of minimum 200 Amps capacity with heat shrinkable coloured sleeves and i/c, SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 36KA for 1 sec.

-

-

-

... More
OUTGOING

-

-

-

... More
100A FP MCCB, 25kA - 2NO

-

-

-

... More
63A FP MCCB, 25kA- 5NO

-

-

-

... More
32A FP 16KA T&M based MCB -3NO

-

-

-

-

-

-

... More
panel shall be type-tested assembly (TTA) compliant with IEC 61439,

-

-

-

... More
All outgoing MCCBs shall be MP based with adjustable and inbuilt O/L & S/C protection

-

-

-

... More
All breakers breaking capacities shall be Icu=Ics upto 433 V.

-

-

-

... More
1 Set Rotary operating mechanism and terminal extension spreaders for all the MCCBs. ON/OFF/TRIP indicating LED lamps each with 2 amp back up MCB.

-

-

-

... More
ALL Outgoing shall have Multifunction Meter

-

-

-

... More
FEEDER PANEL 1 OUTDOOR (IP 65 Rated)

3

343823

1031469

... More
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 14 SWG MS sheet after seven tank process and painting with Epoxy powder coating. The panel shall consist of IP55 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. . The Panel shall be testd by OEM and complying to latest IEC standards of 60439. The PCC shall have at least two spare cubicles of the maximum rating. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. For all incomers and outgoings Digital Ammeter with resign cast CTs and selector switches shall be provided.

-

-

-

... More
INCOMER

-

-

-

... More
All Incomer Shall have TVSS Protection of CL-1

-

-

-

... More
100A FP, 25KA MP based MCCB -1NO

-

-

-

... More
Each Incomer shall have one set of the following items:

-

-

-

... More
3 Nos.phase indicating LED lamps each with 2 amp back up MCB. ON/OFF/TRIP indication lamps. Multifunction Meter

-

-

-

... More
BUSBARS TPN aluminium bus bars of minimum 125 Amps capacity with heat shrinkable coloured sleeves and i/c, SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 25 KA for 1 sec.

-

-

-

... More
OUTGOING

-

-

-

... More
63A FP 16KA T&m based MCCB -5NO

-

-

-

... More
32A FP 16KA T&M based MCB -5NO

-

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 110 V, 3 1/2 core 150 sq.mm aluminium conducter complte erected with glands and lungs, on wall/ trusses/pole or laid in provided trench/ pipe as per IS 3961 specifications cables in ground at 750mm below ground level including excavation, and refilling of earth, laying and jointing of cables, providing protection with bricks on top and sides and teliphone cable route markers at every 50 meters interval complete as required and as directed by Engr-in-charge. The cable shall be as per the DOT specifications.

100

1476

147600

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 110 V, 3 1/2 core 95 sq.mm aluminium conducter complte erected with glands and lungs, on wall/ trusses/pole or laid in provided trench/ pipe as per IS 3961 specifications cables in ground at 750mm below ground level including excavation, and refilling of earth, laying and jointing of cables, providing protection with bricks on top and sides and teliphone cable route markers at every 50 meters interval complete as required and as directed by Engr-in-charge. The cable shall be as per the DOT specifications.

2000

1116

2232000

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 110 V, 3 1/2 core 70 sq.mm aluminium conducter complte erected with glands and lungs, on wall/ trusses/pole or laid in provided trench/ pipe as per IS 3961 specificationscables in ground at 750mm below ground level including excavation, and refilling of earth, laying and jointing of cables, providing protection with bricks on top and sides and teliphone cable route markers at every 50 meters interval complete as required and as directed by Engr-in-charge. The cable shall be as per the DOT specifications.

800

950

760000

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 110 V, 3 1/2 core 50 sq.mm aluminium conducter complte erected with glands and lungs, on wall/ trusses/pole or laid in provided trench/ pipe as per IS 3961 specifications cables in ground at 750mm below ground level including excavation, and refilling of earth, laying and jointing of cables, providing protection with bricks on top and sides and teliphone cable route markers at every 50 meters interval complete as required and as directed by Engr-in-charge. The cable shall be as per the DOT specifications.

1200

787

944400

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 110 V, 3 1/2 core 35 sq.mm aluminium conducter complte erected with glands and lungs, on wall/ trusses/pole or laid in provided trench/ pipe as per IS 3961 specifications cables in ground at 750mm below ground level including excavation, and refilling of earth, laying and jointing of cables, providing protection with bricks on top and sides and teliphone cable route markers at every 50 meters interval complete as required and as directed by Engr-in-charge. The cable shall be as per the DOT specifications.

600

673

403800

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 110 V, 4 core 25 sq.mm aluminium conducter complte erected with glands and lungs, on wall/ trusses/pole or laid in provided trench/ pipe as per IS 3961 specifications cables in ground at 750mm below ground level including excavation, and refilling of earth, laying and jointing of cables, providing protection with bricks on top and sides and teliphone cable route markers at every 50 meters interval complete as required and as directed by Engr-in-charge. The cable shall be as per the DOT specifications.

1100

615

676500

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 110 V, 4 core 16 sq.mm aluminium conducter complte erected with glands and lungs, on wall/ trusses/pole or laid in provided trench/ pipe as per IS 3961 specifications cables in ground at 750mm below ground level including excavation, and refilling of earth, laying and jointing of cables, providing protection with bricks on top and sides and teliphone cable route markers at every 50 meters interval complete as required and as directed by Engr-in-charge. The cable shall be as per the DOT specifications.

900

572

514800

... More
SUB HEAD XX : DG Set

-

-

-

... More
Supply, Installation, Tsting & Commissioning of 200KVA DG set with detailed specification as follows. (A) Diesel Engine: Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms

2

1547620

3095240

... More
(CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. (B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication (vi) RPM indication

-

-

-

... More
(vii) Over speed indication (viii) Low lubricantion Oil trip indication (ix) Engine Running Hours indication (x) Fuel Level (C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous

-

-

-

... More
operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. (D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.

-

-

-

... More
(E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.

-

-

-

... More
(F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. (G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.

-

-

-

... More
(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.

-

-

-

... More
(I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP

-

-

-

... More
port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2. Auto/Manual/Test/Off selector switch

-

-

-

... More
3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay). 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF. 6. LED Indicating lamps for load on mains and load on set 7. Fuse/ MCB for instruments 8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. 9. Main supply failure monitor 10. Supply failure timer 11. Restoration timer 12. Control unit with three impulse automatic engine start/stop and failure to start lockout. 13. Impulse counter with locking and reset facility. 14. ON/OFF/Control circuit switch with indicator 15. Audio/Video annunciation for

-

-

-

... More
(i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning 16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour & due date.

-

-

-

... More
18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start/ auto stop depending upon load status and requirement etc. And necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.

-

-

-

... More
SUB HEAD XXI : SOLAR SYSTEM

-

-

-

... More
Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required.

40

54280

2171200

... More
a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730 Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.

-

-

-

... More
b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in 91 DELHI SCHEDULE OF RATES (E&M)-2025 meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown.

-

-

-

... More
The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.

-

-

-

... More
c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.

-

-

-

... More
d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.

-

-

-

... More
e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.

-

-

-

... More
f) Lightning, surge voltage protection, earthing protection and grid islanding.

-

-

-

... More
g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.

-

-

-

... More
h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required.

-

-

-

... More
Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE.

-

-

-

... More
The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0 C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short

-

-

-

... More
circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc

-

-

-

... More
6 KVA

8

109793

878344

... More
SUB HEAD XXII ARBORICULTURE

-

-

-

... More
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).

13

119

1547

... More
Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).

15

803

12056.25

... More
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment)

-

-

-

... More
a) Screened through sieve of I.S. designation 20 mm

30

391

11740.5

... More
b) Screened through sieve of I.S. designation 16 mm

10

447

4470.5

... More
c) Screened through sieve of I.S. designation 4.75 mm

10

491

4916.5

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge

50

55

2785

... More
Grassing with selection No. 1 grass including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and earth shall be paid for separately)

-

-

-

... More
In rows 5 cm apart in both directions

50

26

1347.5

... More
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)

100

339

33985

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :

-

-

-

... More
Holes 90 cm dia, and 90 cm deep

50

155

7775

... More
Holes 60 cm dia, and 60 cm deep

75

47

3588.75

... More
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)

-

-

-

... More
a) Trees Plant

50

9

472.5

... More
b) Shrubs Plant

75

4

352.5

... More
Providing and stacking of Azadirachta indica (Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge.

25

72

1805

... More
Providing and stacking of Casuarina equisetifolia height 150-165 cm in poly bag size 25 cm as per direction of the officer-in-charge.

25

65

1625

... More
Supply and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Varigata, Glabra Formosa, Peruviana Odissi, Partha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) plant of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.

25

40

1000

... More
Providing, stacking and Displaying Gaillardia double hybrid variety well developed 30 to 45 cm ht 20 to 30 fresh & healthy flowers with green painted bamboo stick in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.

25

59

1480

... More
Providing and stacking of Jatropha multifida (red colour) of height 60-75 cm. multibranched in p.bag of size 25 cm as per direction of the officerin-charge.

25

49

1233.75

... More
Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same and maintenance for 30 days or more till the grass establish properly, as per direction of the officer in charge

50

113

5685

... More
SUB HEAD XXIII : DESIGN WORK

-

-

-

... More
Providing services of architectural planning and structural design/drawing for scope of work as per BOQ of the enquiry including preparation of architectural drawing through an architect registered with Council of Architect – Delhi and with the approval of CCE(R&D) preferably DRDO enlisted agencies inclusive of building plan, elevation, sectional elevation, detailed working drawing of building doors, windows, column, beam, staircase, slab and fittings etc. with Electrical & Mechanical services, structural design of RCC/Steel structure, proof checking of structural and electrical designs from IIT/NIT or equivalent engineering college approved by CCE(R&D), furnishing shop drawings. Good for construction drawings (6 Nos) and also As Built Drawings (3 Copies) with soft copy after completion of work etc. all complete including the entire parts of building work, E&M services, ELV servies, sewage disposal, water supply, sanitary installations, drainage, Air conditioning etc. as per direction of Engineer-in-charge. (Dimension/Area can vary up to 20% without extra remuneration). Terms Of Payment : i) 20% on submission of approved working drawings with proof checking documents. ii) 20-85% During the progress of work and balance 15% after completion and submission of As Build Drawings & Soft Copy)

1

3897225

3897225



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.