Electricity Department Tender

... More
The Electricity Department has issued a formal invitation for competitive bids for Tender For The Work Of Erection Of New T/c To Resolve Low Voltage Issue At Cotombi Baag Under V.p Avedem In Quepem Constituency, Under The Jurisdiction Of Sub Div-ii, Quepem-goa in South Goa, Goa, with an estimated contract value of Rs. 1,01,92,979. The bid opening date for this tender is 27-05-2025 and the last date for bid submission is 17-06-2025. Interested bidders for Electricity Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Electricity Department Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 May 2025
Closing Date17 Jun 2025
Tender Amount₹ 1,01,92,979 
Notes
Download

Costs

  • EMD

    ₹ 2,03,860
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker conforming to International Standards and complete with Fault Passage Indicator other accessories of approved make.

1

735000

-

... More
Supply of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make .

3

8840

-

... More
Supply of 11KV 3 phase Indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 120sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make.

1

7873

-

... More
Supply of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 120sq.mm including sockets/lugs/connectors etc. for connecting Transformer for main section side of approved make.

1

10931

-

... More
Supply of straight through joint complete for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc. of approved make.

6

29559

-

... More
Supply of Cable route Markers (for entire HT/LT cable route length ) as per NIT drawing.

22

528

-

... More
Supply and laying of fine river sand of approved quality for cushioning of HT/ LT underground cables laid by conventional Open Trenching Method.

121.73

2170

-

... More
Supply of concrete slab shall be machine made using semi-dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in afully automatic "Vibro Press" machine with a high vibration frequency and hydraulic pressure of 40MT, the size of the slab shall be 40mmx250mmx50mm,(+/-2mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30N/mm2 (28days strength) when tested.

4328

135

-

... More
Supply of wire cut brick for 11kv cable sepration

5410

9

-

... More
S.E.T.C. of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMU's, Transformers, LVSB's, Feeder Pillar's, Service Pillar's , Streetlight Pillar's, Streetlight Poles . The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling & spreading of excavated surplace earth evenly at RMU's, LV Switchboard etc.

2

4428

-

... More
Supply of HDGI flat of size 25mm x 5mm for earthing of RMU's, Transformers, LVSB's, Feeder Pillar's, Service Pillar's , Streetlight Pillar's, Streetlight Poles

10

116

-

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations of RMU's, Transformers, LVSB's, Feeder Pillar's, Service Pillar's , Streetlight Pillar's, cement concrete for laying foundation for octagonal poles including the cost of centering, shuttering and muffing 0.5 m above ground and of diameter 0.5 m (Pit dimensions : 0.5 X 0.5 X 1.2 mts.)

0.5

5555

-

... More
Supply & Providing Centering and shuttering including struttings, propping etc. and removal of formwork for a) Foundations, footings, bases of columns and mass concrete for Feeder Pillar's, Service Pillar's , Streetlight Pillar's, Streetlight Poles

3.5

563

-

... More
Supply & Providing of 12 mm cement plaster 1:4 ( 1 cement: 4 fine sand) for foundations of Feeder Pillar's, Service Pillar's , Streetlight Pillar's

0.7

147

-

... More
Supply of FRP Fencing complete with Gate around every distribution sub-station containing RMU, one distribution transformer and one LV switchboard including danger plate (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

76667

-

... More
Supply of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.

20

407

-

... More
Supply of GI Pipe 150mm, class B for Nala/drainage/bridge crossing

30

1681

-

... More
Supply of 9mts. long RCC poles by digging pit of size 0.60mtsX0.60mtsX1.5 mts.deep in all types of soil laterite/hard rock, including refilling of soil,leveling & disposal of extra soil supply and erection of poles as per the specification mentioned.

2

8386

-

... More
Supply & laying of Cement Concrete 1:2:4 (1-cement: 2-sand :4-graded granite/basaltic aggregate 20mm nominal size ) including the cost of centreing, shuttering & muffing 0.3mts above ground.Concreting as per the Specifications mentioned.

1.08

5555

-

... More
Supply of HDGI 4pin X arm of made of channel ISMC 70X40X6mm .Supply & fixing as per specification mentioned.

2

1109

-

... More
Supply of HDGI 2pin X arm of made of channel ISMC 70X40X6mm. Supply & fixing as per specification mentioned.

2

569

-

... More
Supply of HDGI LA X arm clamp for 9 mts long RCC Pole

2

266

-

... More
Supply of HDGI SA X arm clamp for 9 mts long RCC Pole

2

266

-

... More
Supply of HDGI Guard cross arm ISMC channel, 75 x 40mm, 1.3 mts long of minimum tensile strength 410 MPA conforming to IS 2062 as amended upto date

1

1959

-

... More
Supply of HDGI Guard cross arm ISMC channel, 75 x 40mm, 1.5 mts long of minimum tensile strength 410 MPA conforming to IS 2062 as amended upto date

1

2196

-

... More
Supply of HDGI Top fitting cross arm ISMC channel, 75x40mm, 0.7mts long

1

819

-

... More
Supply of 11 KV Disc Insulator 70KN with H.D.G.I. Metal parts.

3

2886

-

... More
Supply of 11KV Pin Insulators with HDGI Pin.

3

693

-

... More
Supply of Insulator -(LT) Shackle with HDGI Metal Parts.L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS

12

372

-

... More
Supply of ACSR 'WEASEL' of size ( 6/1/2.59mm) for earthing and jumpering .Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.18

33409

-

... More
Supply of Anticlimbing device(barbed wire).Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979as amended upto date

2

145

-

... More
Supply of Enamelled danger board.

2

248

-

... More
Supply of Earthing complete with 2.5mts long, 40mm GI earthing pipe, class B, 20kgs each of salt and charcoal, excvation, re-filling etc.Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date

6

4428

-

... More
Supply of GI stay rod with plate complete for 9.0 mts pole.Comprises of stay rod, stay plate conforming to drawing enclosed. The stay wire of size 7/10swg alongwith the break insu¬lator of 15KV/8KV respectively to be used alongwith suitable HDGI stay clamps, HDGI nut bolts, and HDGI turn buckle conforming to drawing enclosed, clamps conforming to drawing enclosed. The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions there of. The wires shall be of tensile grade 4 & having minimum tensile strength of 700 N/mm2 conforming to IS: 2141. GI stay rod of 1800mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanized. GI stay plate of 450x450x8mm size with a hole Set drilled at the centre to suit 16mm dia GI rod galvanized. GI stay wire standard of size 7/3.15mm (7/10SWG) wire should conform to ISS-2141/68 grade I and hot dipped galvanized as per IS 4826/1968 with up to date amendments. Two nos of GI square washer of size 40x40x6mm to suit the 16mm dia GI rod. Two nos of GI hexagonal nut and bolt suitable for threaded portion of the stay rod mentioned above and conforming to IS-1365/67 with amendment No-1. All the GI materials shall conform to IS-226/75 with amendment No- 1 to 3 tested quality

2

4367

-

... More
Supply of HDGI Structure Materials

274

169

-

... More
Supply of 11 KV GOAB switch with 200 A.12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy

1

23535

-

... More
Supply of 11 KV HG fuse,200A, Horn gap type fuse I.TECHNICAL PARTICULARS: 1. Highest System voltage : 12 KV (R.M.S) 2. Impulse voltage withstand voltage : 75 KV (Peak) 3. One minute power frequency withstand voltage : 35 KV (R.M.S.) 4. Continuous current rating of the unit : 200 Amps

1

10450

-

... More
Supply of 9 KV, 5A Lightning Arrestor, pole mounted.9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS

3

3033

-

... More
Supply of MS Distribution box complete.M. S. distribution box MCCB of 400 Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals.

1

63140

-

... More
Supply of XLPE armoured cable 1 core 300 sq.mm.The unarmoured cable shall be of 1 core and of sizes as required i.e. 95 sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

144

555

-

... More
Supply of XLPE armoured cable 1 core 185 sq.mm.The unarmoured cable shall be of 1 core and of sizes as required i.e. 120Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

48

245

-

... More
Supply of HDGI nuts & bolts various sizes. G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date

10

228

-

... More
Supply of Aluminum crimping lugs 300 Sq.mm.

4

124

-

... More
Supply of Aluminum crimping lugs 185 Sq.mm.

8

78

-

... More
Supply of Allminium crimp lugs 70Sqmm

30

34

-

... More
Supply & Providing of Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete for single and Double Circuit 11KV Cable trench

189.18

2211

-

... More
Erection Cost

-

-

-

... More
Laying, Testing & Commissioning of 11KV, 3 core, 300 sq.mm. aluminium, XLPE insulated, flat armoured, 11 KV (Earthed) Cable, type A2XFY of approved make conforming I.S. 7098 PART 2 and carrying ISI MARK through open trench method in any type of soil including hard laterite.

2200

342

-

... More
Laying, testing & commisioning of 11KV, 3 core 120 sq.mm aluminium, XLPE insulated, flat armoured, 11 KV (Earthed) Cable, type A2XFY of approved make conforming I.S. 7098 PART 2 and carrying ISI MARK through conventional open trenching method in any type of soil including hard laterite.

16

216

-

... More
Erection, Testing & Commissioning of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker conforming to International Standards and complete with Fault Passage Indicator other accessories of approved make.

1

9720

-

... More
Erection, Testing & Commissioning of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make .

3

2548

-

... More
Erection, Testing & commissioning of 11KV 3 phase Indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 120sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make.

1

2548

-

... More
Erection, Testing & Commissioning of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 120sq.mm including sockets/lugs/connectors etc. for connecting Transformer for main section side of approved make.

1

2648

-

... More
Providing, Testing & Commissioning of straight through joint complete for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc. of approved make.

6

3713

-

... More
Erection of Cable route Markers (for entire HT/LT cable route length ) as per NIT drawing.

22

256

-

... More
Excavation in any type of soil including hard laterite soil by mechanical means( hydraulic excavator)/manual means for laying of HT/LT cables of various sizes including excavation for equipment foundations i.e for including excavation for equipment foundations i.e for RMU's, Transformers, LVSB's, Feeder Pillar, Service Pillar Octagonal Poles etc. including getting out the excavated soil and disposal of surplus excavated soil.

732.48

468

-

... More
Refilling of excavated soil in the foundations, trenches etc. with avialable excavated earth in layers not exceeding 20 cm depth, cosolidating each layer by ramming and watering lead upto 50 M and all lifts and disposal of surplus earth in cable trenches and foundations of equipments.

594.26

120

-

... More
Laying of RCC protective covers of size 600mm length x 250mm width x 50mm thick bearing load of 135 Kg & covered with earth/ sand upo depth of 0.15 mtrs confirming to IS 1256-1967 at non road crossing.

4328

60

-

... More
Providng of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMU's, Transformers, LVSB's, Feeder Pillar's, Service Pillar's , Streetlight Pillar's, Streetlight Poles . The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling & spreading of excavated surplace earth evenly at RMU's, LV Switchboard etc.

2

2665

-

... More
Erection of HDGI flat of size 25mm x 5mm for earthing of RMU's, Transformers, LVSB's, Feeder Pillar's, Service Pillar's , Streetlight Pillar's, Streetlight Poles

10

48

-

... More
Erection of FRP Fencing complete with Gate around every distribution sub-station containing RMU, one distribution transformer and one LV switchboard including danger plate (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

35000

-

... More
Laying of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.

20

151

-

... More
Laying of GI Pipe 150mm, class B for Nala/drainage/bridge crossing

30

182

-

... More
Carrying out detailed physical survey of the area including detailed GPS survey which includes indicating and marking location of other utilities if any, furnishing of optimum and economical route and design for layong of LT, XLPE cables of various size and accessories, including plotting on the scaled land base map of size 1:1000 indicating all features and submitting drilling profile indicating proposed plan for open trenching,road,nullah,culvet, over bridge, rail crossing, or any other special crossing. The work shall include digging of trial pits at suitable intervals and re-instatement of dug-up area of trial pits. The detailed documents as well as the write-up shall be furnished in 02 nos. of hard copies and soft copies for approval.Upon approval fresh 06 Nos. of hard copies alongwith a soft copy shall be furnished duly corrected. On completion, the contractor has to submit final survey map with longitude and latitude of each every item with other details for asset mapping.

1.1

15000

-

... More
Erection of 9mts. long RCC poles by digging pit of size 0.60mtsX0.60mtsX1.5 mts.deep in all types of soil laterite/hard rock, including refilling of soil,leveling & disposal of extra soil supply and erection of poles as per the specification mentioned.

2

5900

-

... More
Fixing of HDGI 4pin X arm of made of channel ISMC 70X40X6mm .Supply & fixing as per specification mentioned.

2

261

-

... More
Fixing of HDGI 2pin X arm of made of channel ISMC 70X40X6mm. Supply & fixing as per specification mentioned.

2

232

-

... More
Fixing of HDGI LA X arm clamp for 9 mts long RCC Pole

2

45

-

... More
Fixing of HDGI SA X arm clamp for 9 mts long RCC Pole

2

45

-

... More
Fixing of HDGI Guard cross arm ISMC channel, 75 x 40mm, 1.3 mts long of minimum tensile strength 410 MPA conforming to IS 2062 as amended upto date

1

492

-

... More
Fixing of HDGI Guard cross arm ISMC channel, 75 x 40mm, 1.5 mts long of minimum tensile strength 410 MPA conforming to IS 2062 as amended upto date

1

546

-

... More
Fixing of HDGI Top fitting cross arm ISMC channel, 75x40mm, 0.7mts long

1

228

-

... More
Fixing of 11 KV Disc Insulator 70KN with H.D.G.I. Metal parts.

3

375

-

... More
Fixing of 11KV Pin Insulators with HDGI Pin.

3

152

-

... More
Fixing of Insulator -(LT) Shackle with HDGI Metal Parts.L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS

12

208

-

... More
Stringing of ACSR 'WEASEL' of size ( 6/1/2.59mm) for earthing and jumpering .Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.18

11000

-

... More
Fixing of Anticlimbing device(barbed wire).Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979as amended upto date

2

46

-

... More
Providing of Enamelled danger board.

2

57

-

... More
Providing of Earthing complete with 2.5mts long, 40mm GI earthing pipe, class B, 20kgs each of salt and charcoal, excvation, re-filling etc.Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date

6

2665

-

... More
Erection of GI stay rod with plate complete for 9.0 mts pole.Comprises of stay rod, stay plate conforming to drawing enclosed. The stay wire of size 7/10swg alongwith the break insu¬lator of 15KV/8KV respectively to be used alongwith suitable HDGI stay clamps, HDGI nut bolts, and HDGI turn buckle conforming to drawing enclosed, clamps conforming to drawing enclosed. The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions there of. The wires shall be of tensile grade 4 & having minimum tensile strength of 700 N/mm2 conforming to IS: 2141. GI stay rod of 1800mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanized. GI stay plate of 450x450x8mm size with a hole Set drilled at the centre to suit 16mm dia GI rod galvanized. GI stay wire standard of size 7/3.15mm (7/10SWG) wire should conform to ISS-2141/68 grade I and hot dipped galvanized as per IS 4826/1968 with up to date amendments. Two nos of GI square washer of size 40x40x6mm to suit the 16mm dia GI rod. Two nos of GI hexagonal nut and bolt suitable for threaded portion of the stay rod mentioned above and conforming to IS-1365/67 with amendment No-1. All the GI materials shall conform to IS-226/75 with amendment No- 1 to 3 tested quality

2

2466

-

... More
Fixing of HDGI Structure Materials

274

47

-

... More
Erection of 11 KV GOAB switch with 200 A.12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy

1

3971

-

... More
Erection of 11 KV HG fuse,200A, Horn gap type fuse I.TECHNICAL PARTICULARS: 1. Highest System voltage : 12 KV (R.M.S) 2. Impulse voltage withstand voltage : 75 KV (Peak) 3. One minute power frequency withstand voltage : 35 KV (R.M.S.) 4. Continuous current rating of the unit : 200 Amps

1

3368

-

... More
Erection of 9 KV, 5A Lightning Arrestor, pole mounted.9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS

3

174

-

... More
Erection of MS Distribution box complete.M. S. distribution box MCCB of 400 Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals.

1

8795

-

... More
Erection of Distribution Transformer 100 KVA. of Distribution Transformer 100 KVA.11/0.433KV, 50HZ, outdoor type, oil immersed, core type, Oil Natural Air Natural Cool type, Delta Star Dy11 aluminium wound, distribution transformer (without taps) as per specification.

1

11017

-

... More
Laying of XLPE armoured cable 1 core 300 sq.mm.The unarmoured cable shall be of 1 core and of sizes as required i.e. 95 sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

144

279

-

... More
Laying of XLPE armoured cable 1 core 185 sq.mm.The unarmoured cable shall be of 1 core and of sizes as required i.e. 120Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

48

228

-

... More
Providing of HDGI nuts & bolts various sizes. G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date

10

30

-

... More
Providing of Aluminum crimping lugs 300 Sq.mm.

4

101

-

... More
Providing of Aluminum crimping lugs 185 Sq.mm.

8

95

-

... More
Providing of Allminium crimp lugs 70Sqmm

30

59

-

... More
Restringing of ACSR WEASEL Conductor

0.15

10665

-

... More
Removing of ANT conductor

0.12

3317

-

... More
Restringing of ANT Conductor

0.12

6634

-

... More
Removing of GNAT conductor

0.12

3091

-

... More
Restringing of GNAT conductor

0.12

6183

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.