Electricity Department Tender

... More
The Electricity Department has issued a formal invitation for competitive bids for Tender For The Work Arranging Power Supply To 1 No. Of 3 Ph. Ltc Connection Of V.p. Navelim Mrf Shed , S.no. 184.0, Maina Navelim For A Distance Of 60 Mtrs For A Load Of 40kw In The Jurisdiction Of S.o. Kudne, S.d. Ii, Sakhali. in North Goa, Goa, with an estimated contract value of Rs. 20,15,403. The bid opening date for this tender is 26-05-2025 and the last date for bid submission is 03-06-2025. Interested bidders for Electricity Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Electricity Department Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date26 May 2025
Closing Date3 Jun 2025
Tender Amount₹ 20,15,403 
Notes
Download

Costs

  • EMD

    ₹ 40,308
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 4,031

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Erection, Testing & Commissioning of 11 KV Straight Through joint 3 core 300 sqmm XLPE

2

29559

-

... More
Supply, Erection, Testing & Commissioning of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

10

1240

-

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit Indoor 3 core 95 sqmm XLPE

1

6731

-

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit Outdoor 3 core 95 sqmm XLPE

1

10152

-

... More
Supply and Erection of XLPE cable Single core 185 sq.mm unarmoured

20

245

-

... More
Supply and Erection of XLPE cable armoured 3 ½ C X 95 sq.mm 1.1 KV Grade

60

750

-

... More
MS Distribution box as per drg No. CEE/E-689 Revision No. 3 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm,aluminium 'J' type fuse links (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 200 KVA Distribution Transformer centre

1

63140

-

... More
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. Sand for cushioning of HT underground cables.

3.6

2170

-

... More
Supply and laying of RCC Protective cover of size 480mm length x 250mm width x 50mm byconfined mold vibrant cast of concrete mix M30, having strength of 30 N/mm2 at 28 days.

28.8

135

-

... More
Supply and laying of Class B HDGI pipe of diameter 100 mm dia.

12

811

-

... More
Stay set For 7.5 mtrs long RCC pole

2

3976

-

... More
AAC ANT conductor

1

60500

-

... More
ACC GNAT Conductor

0.2

31000

-

... More
Civil work cost

1

959767

-

... More
Cost of Erection

-

-

-

... More
Supply,Testing and Erection of 11KV/433V, 100 KVA outdoor type oil immersed aluminium wound Level II Distribution transformer.

1

11017

-

... More
11KV, 630 Amps, outdoor, SF6 Ring Main Unit with Two Load Break Switches and one circuit breaker

1

9720

-

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit Indoor 3 core 300 sqmm XLPE

2

2548

-

... More
Supply, Erection, Testing & Commissioning of 11 KV Straight Through joint 3 core 300 sqmm XLPE

2

3713

-

... More
Supply of 11KV, 3 core 300sq.mm A2XFY Aluminium Armoured XLPE Cable

20

342

-

... More
Supply, Erection, Testing & Commissioning of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

10

199

-

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit Indoor 3 core 95 sqmm XLPE

1

2538

-

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit Outdoor 3 core 95 sqmm XLPE

1

2648

-

... More
Supply and Erection of XLPE cable Single core 185 sq.mm unarmoured

20

170

-

... More
Supply and Erection of XLPE cable armoured 3 ½ C X 95 sq.mm 1.1 KV Grade

60

149

-

... More
MS Distribution box as per drg No. CEE/E-689 Revision No. 3 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm,aluminium 'J' type fuse links (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 200 KVA Distribution Transformer centre

1

8795

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :a) All kinds of soil b) All types of Ordinary rock including all types of laterite rock, blasting prohibited

21.6

763

-

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge

18

120

-

... More
Supply and laying of RCC Protective cover of size 480mm length x 250mm width x 50mm byconfined mold vibrant cast of concrete mix M30, having strength of 30 N/mm2 at 28 days.

28.8

60

-

... More
Supply and laying of Class B HDGI pipe of diameter 100 mm dia.

12

92

-

... More
Al. 300 sq.mm Lugs

8

101

-

... More
Al. 95 sq.mm Lugs

8

65

-

... More
HDGI 4 pin cross Arm channel type

3

261

-

... More
HDGI 2 pin cross Arm channel type

12

232

-

... More
GI X arm clamps for LA/ SA for 7.5 mtrs RCC pole

13

32

-

... More
GI X arm clamps for LA/ SA for 9 mtrs RCC pole

2

45

-

... More
LT Shuckle Insulators with metal Part

18

208

-

... More
LT Pin Insulators with GI Pin

21

173

-

... More
Stay set For 7.5 mtrs long RCC pole

2

2391

-

... More
AAC ANT conductor

1

10300

-

... More
ACC GNAT Conductor

0.2

9100

-

... More
GI nut and bolts

3.8

30

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.