Electricity Department Tender

... More
The Electricity Department has issued a formal invitation for competitive bids for Tender For Erection Of 200 Kva Dtc Plinth Mounted Along With 11 Kv Ug Cable At V.p Keri To Release 1 No. Of Nds1 Service Connection To Panchayat Building Keri For Total Connected Load Of 55.32 Kw, In The Jurisdictionof S.o Parye Under Sdii, Sankhali in North Goa, Goa, with an estimated contract value of Rs. 34,56,451. The bid opening date for this tender is 13-11-2026 and the last date for bid submission is 23-11-2026. Interested bidders for Electricity Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Electricity Department Tender - Goa Tender

Opening Date13 Nov 2026
Closing Soon23 Nov 2026
Tender Amount₹ 34,56,451 
Notes
Download

Costs

  • EMD

    ₹ 69,129
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 6,000

Description

Tender For Erection Of 200 Kva Dtc Plinth Mounted Along With 11 Kv Ug Cable At V.p Keri To Release 1 No. Of Nds1 Service Connection To Panchayat Building Keri For Total Connected Load Of 55.32 Kw, In The Jurisdictionof S.o Parye Under Sdii, Sankhali

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
Supply & Erection of Enamelled danger boards 11000 Volts ,250mm x 200mmm

4

248

992

... More
Supply & Erection of 3 Core XLPE cable 11KV armoured cable 95 sq.mm

20

1520

30400

... More
Supply & Erection of 3 Core XLPE cable 11KV armoured cable 300 sq.mm

280

3150

882000

... More
Supply, Erection of Testing & Commissioning of of 11 KV Termination kit Indoor 3 core 300 sqmm XLPE

2

8840

17680

... More
Supply & Erection of 11KV 3 phase indoor terminating kit to be used with cables - 95 sq.mm.

1

6731

6731

... More
Supply & Erection of 11KV 3 phase outdoor terminating kit to be used with cables - 95 sq.mm.

1

10152

10152

... More
H.S 11KV Straight through joint 3 core 240 to 400sqmm

2

29559

59118

... More
River Sand (except in sandy soil) bed of 200mm for cushioning of 11 KV XLPE underground cable, as per technical specifications & as per direction of the Engineer-in-charge. (Sand Qty = Length * Trench Width * 0.20) (240*0.30*0.20 + 1.8)

16.2

2170

35154

... More
Supply and laying of underground cable protective cover as per specification as given below: The concrete slab shall be machine made using semidry concrete that is batched in a fully autimatic PLC controlled concrete batching plant and cast in a fully automatic "vibro-Press" machine with a high vibration frequency and hyraulic pressure of 40 MT, the size of the slab shall be 480mm x 250mm x 50 mm, (+/- 2mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 N/mm2/(28 days strength) when tested.( No.of Covers= Cable legnth/length of one cover) (240*0.5+62)

542

135

73170

... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed) (one per every 100m for entire route length & joints)

2

528

1056

... More
Supply & Erection of Bricks class design 75 kg/cm2 (1st class wire cut) (No. of Bricks required= Cable length/length covered by one bricks) (240/0.23)

1043

9

9908.5

... More
Supply & Erection of 3-WAY RMU, 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker confirming to IS & complete with fault passage indicator

1

620750

620750

... More
Supply & Erection of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary.

8

4428

35424

... More
Supply & erection 200 KVA 11kv/0.433 kv 3phase outdoor type,oil immersed aluminum wound level II Distribution Transformers level II losses,

1

490000

490000

... More
Supply & Erection of Distribution Boxes (M.S) with 400Amps MCCB & Kit-Kat fuses

1

63140

63140

... More
Supply & Stringing of XLPE 1CX 300mm2 unarmoured cable

60

670

40200

... More
Supply & Stringing of XLPE 1CX 50 mm2 unarmoured cable

30

160

4800

... More
Supply & Erection of HDGI flat of size 50 mm x 5mm for earthing.

36

208

7488

... More
Supply & Erection of DTC metering unit

1

25688

25688

... More
Supply & Erection of Modem for Automatic Meter Reading

1

6000

6000

... More
Supply & Erection of Aluminum lug 300Sqmm

8

124

992

... More
Supply & Erection of Aluminum lug 120 Sqmm

6

54

324

... More
Supply & Erection of Aluminum lug 95 Sqmm

2

40

80

... More
Supply & Erection of Aluminum lug 50 Sqmm

10

22

220

... More
Supply & Erection of GI tubular Fencing complete with gate (4MX3MX2M) & side dismantling system with concreting for GI fencing supports with plint (0.3X0.3X05) Cumtr X12Nos .Each Ratio 1:3:6 and brick masonary ( Galvanising should be hot dipped galvanised as per IS :2629/66 minimum zinc coating of 1000gms/sq.mtr ,140microns DFT,Suitable for high salinity coastal areas )

1

94300

94300

... More
Supply & Erection of GI pipe 150mm class B

10

1681

16810

... More
Warning tape

0.14

15000

2100

... More
Cost of Erection

-

-

-

... More
Supply & stringing of XLPE 1.1KV 3 & 1/2 XLPE Armoured cable 120 mm²

40

176

7040

... More
Supply & Erection of Enamelled danger boards 11000 Volts ,250mm x 200mmm

4

57

228

... More
Supply & Erection of 3 Core XLPE cable 11KV armoured cable 95 sq.mm

20

199

3980

... More
Supply & Erection of 3 Core XLPE cable 11KV armoured cable 300 sq.mm

280

342

95760

... More
Supply, Erection of Testing & Commissioning of of 11 KV Termination kit Indoor 3 core 300 sqmm XLPE

2

2548

5096

... More
Supply & Erection of 11KV 3 phase indoor terminating kit to be used with cables - 95 sq.mm.

1

2538

2538

... More
Supply & Erection of 11KV 3 phase outdoor terminating kit to be used with cables - 95 sq.mm.

1

2648

2648

... More
H.S 11KV Straight through joint 3 core 240 to 400sqmm

2

3713

7426

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :a) All kinds of soil b) All types of Ordinary rock including all types of laterite rock, blasting prohibited.(Excavation Qty (m3)= Trench Length (m) * Trench Width (m) * Trench Depth (m) ) (240*0.30*1.2 + 9.9)

96.3

763

73476.9

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge (Excavation Qty-Sand Qty) (96.3-16.2)

80.1

120

9612

... More
Supply and laying of underground cable protective cover as per specification as given below: The concrete slab shall be machine made using semidry concrete that is batched in a fully autimatic PLC controlled concrete batching plant and cast in a fully automatic "vibro-Press" machine with a high vibration frequency and hyraulic pressure of 40 MT, the size of the slab shall be 480mm x 250mm x 50 mm, (+/- 2mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 N/mm2/(28 days strength) when tested.( No.of Covers= Cable legnth/length of one cover) (240*0.5+62)

542

60

32520

... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed) (one per every 100m for entire route length & joints)

2

256

512

... More
Supply & Erection of 3-WAY RMU, 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker confirming to IS & complete with fault passage indicator

1

9720

9720

... More
Supply & Erection of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary.

8

2665

21320

... More
Supply & erection 200 KVA 11kv/0.433 kv 3phase outdoor type,oil immersed aluminum wound level II Distribution Transformers level II losses,

1

15638

15638

... More
Supply & Erection of Distribution Boxes (M.S) with 400Amps MCCB & Kit-Kat fuses

1

8795

8795

... More
Supply & Stringing of XLPE 1CX 300mm2 unarmoured cable

60

218

13080

... More
Supply & Stringing of XLPE 1CX 50 mm2 unarmoured cable

30

56

1680

... More
Supply & Erection of HDGI flat of size 50 mm x 5mm for earthing.

36

48

1728

... More
Supply & Erection of DTC metering unit

1

1072

1072

... More
Supply & Erection of Aluminum lug 300Sqmm

8

101

808

... More
Supply & Erection of Aluminum lug 120 Sqmm

6

88

528

... More
Supply & Erection of Aluminum lug 95 Sqmm

2

65

130

... More
Supply & Erection of Aluminum lug 50 Sqmm

10

51

510

... More
Supply & Erection of GI tubular Fencing complete with gate (4MX3MX2M) & side dismantling system with concreting for GI fencing supports with plint (0.3X0.3X05) Cumtr X12Nos .Each Ratio 1:3:6 and brick masonary ( Galvanising should be hot dipped galvanised as per IS :2629/66 minimum zinc coating of 1000gms/sq.mtr ,140microns DFT,Suitable for high salinity coastal areas )

1

30000

30000

... More
Supply & Erection of GI pipe 150mm class B

10

182

1820

... More
Laterite Masonary works ,Rubber packing with hard laterirate stone under floors inclduing watern ramming and consolidating etc. in pipeline trenches and other foundation completer for B) Double circulit 11KV Cable trench (0.2*0.7*1.00)i.e 0.14 per RM

4.2

2211

9286.2

... More
InHard Laterirate stone Laying of 11KV HT/LT UG cable by trenchless technology by adopting horizontal directional drilling(HDD method). The work includes preparation of site, boring as well as drawing of cable in hard/laterite soil including soft, watery and sandy soil with minimum 8'' bore size . including supply & erection of HDPE pipe 110mm,PN^,PE80 wall thickness 6.5mm(minimum) as per IS 4984:1995 ammendment 2016.The Depth shall be 1.650m to 1.850m(1650mm-1850mm) only execept at entry adn exist pits whereminuium depth shall be 1200mm

60

3600

216000

... More
Estimate II

-

-

-

... More
Cost of Material

-

-

-

... More
Supply & Erection of 9 mtr RCC pole

2

8386

16772

... More
Supply & Erection of 4 pin X arm channel with clamps & nut bolt of 9 mtr RCC pole

5

1466

7331

... More
Supply & Erection of 2 pin X arm channel with clamps & nut bolt of 9 mtr RCC pole

5

926

4631

... More
Supply & Erection of LT Shackle insulator with metal parts

32

372

11904

... More
Supply & Erection of ANT conductor

0.2

90000

18000

... More
Supply & Erection of GNAT Conductor

0.2

46000

9200

... More
Supply & erection of LT/11KV Stay set complete 9 Mts long RCC pole

3

4366

13099.62

... More
Cost of Erection

-

-

-

... More
Supply & Erection of 9 mtr RCC pole

2

5900

11800

... More
Supply & Erection of 4 pin X arm channel with clamps & nut bolt of 9 mtr RCC pole

5

318

1590

... More
Supply & Erection of 2 pin X arm channel with clamps & nut bolt of 9 mtr RCC pole

5

289

1445

... More
Supply & Erection of LT Shackle insulator with metal parts

32

208

6656

... More
Supply & Erection of ANT conductor

0.2

10300

2060

... More
Supply & Erection of GNAT Conductor

0.2

9100

1820

... More
Supply & erection of LT/11KV Stay set complete 9 Mts long RCC pole

3

2465

7397.64

... More
Civil Estimate

-

-

-

... More
Cost of Erection

-

-

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : All kinds of soil

12.12

288

3491.65

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.

0.62

2188

1357.11

... More
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: All works upto plinth level

0.41

6261

2567.32

... More
Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand: 3 graded stone agg 20mm nominal size) All works upto plinth level

6.64

7106

47185.3

... More
Centering & shuttering including Strutting, Propping & removal of forms for: Foundations ,footings ,bases for columns

19.5

402

7857.14

... More
Providing TMT steel reinforcement bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.))(Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in allthe floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.

1170

103

121621.5

... More
12mm Cement plaster 1:4(1 Cement : 4 Fine sand )

16.02

220

3536.74

... More
Painting three or more coats of arcyllic exterior paints of approved brand and manufacture( Such as weather shield ,APEX) including applying one coat of cement primer and one coat of surfae treatment etc. complete

16.02

205

3298.84

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directe

2.47

242

599.1



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.