Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Energy, Oil and Gas
Eprocure
Opening Date4 Jan 2025
Closing Date18 Jan 2025
Tender Amount₹ 9,55,86,675 
Notes
Download

Costs

  • EMD

    ₹ 19,11,734
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Sand for cushoning of HT underground cables. Single circuit cable sand required = (0.4*0.2*Length of trench - 3.14*0.10*0.10*Length of cable) Double circuit cable sand required = (0.6*0.2*Length of trench - 3.14*0.10*0.10*Length of cable*2 - 0.2*length of trench*0.1)

1370.9

2170

2974853

... More
Supply of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable .

19000

2595

49305000

... More
Supply and erection of straight through joint for 300sq.mm cable

74

29559

2187366

... More
Supply and laying of underground cable protective covers as per specification as given below : PCC precast cable protective cover of size 480 mm x 250mm x 50mm casted by confined mold vibratory cast of concrete mixM30, having strength of 30N/mm2 at 28 days

40400

135

5454000

... More
Warning tape.

20

15000

300000

... More
11KV, 3 core, 95sq.mm, AL conductor, XLPE insulated, armoured cable (from the RMU to the transformer)

352

1240

436480

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

53

8840

468520

... More
11KV 3 phase outdoor terminating kit to be used with cables - 300sq.mm.

6

11667

70002

... More
11KV 3 phase indoor terminating kit to be used with cables - 95sq.mm.

16

6731

107696

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

16

10152

162432

... More
Cable Route marker

400

528

211200

... More
Earthing with 40mm, 8" long GI pipe with chamber.

50

2730

136500

... More
HDGI flat of size 25mm x 5mm for earthing.

400

116

46400

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS a. Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxiliary PT as per specification shall be provided in RMU.

8

720000

5760000

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth , 1.5 m in width as well as 10sq .m on plan) including disposal of excavated earth lead up to 50 m and lift upto 1.5 m disposed earth to be leveled and neatly dressed including providing barricating, danger lighting guarding as directed in : All types of ordinary rock including all types of laterite rock , blasting prohibited . ( 5 cu.m )

40

639

25560

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer rammming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in charge =(0.29 m3 )

2.32

245

568.4

... More
Providing and laying in position cement concrete 1:2:6 (1 cement : 3 coarse sand: 6 graded granitic or basaltic stone aggregate 20 m nominal size) excluding cost of centering, stuttering and finishing : All works up plinth level (0.32 cu. M.)

2.56

6325

16192

... More
Centering & shuttering including strutting propping & removal of forms for : (i) Foundations, Footings, Bases for columns ( 1.84 sq m )

14.72

407

5991.04

... More
Centering & shuttering including strutting propping & removal of forms for : (ii)Vertical surface such as retaing walls, return walls, partitions, walls ( any thickness) including attached pilasters, buttresses, plinth and string courses, fillets and the like ( 7.44 sq m )

59.52

479

28510.08

... More
providing and laying in position cement concrete 1:11/2:3) reinforced cement concret excluding the cost of centering shuttering, finishing and reinforcement (1 cement : 1 % coarse sand :3 graded stone agg 20mm nominal size) (a) All works up plinth level (0.27 cu. M.)

2.16

7178

15504.48

... More
providing and laying in position cement concrete 1:11/2:3) reinforced cement concret excluding the cost of centering shuttering, finishing and reinforcement (1 cement : 1 % coarse sand :3 graded stone agg 20mm nominal size) (b) In walls ( any thickness) including attached pilasters, buttresses, plinth and string courses, fillets,columns, pillars, piers, abutments, posts and structs etc. up to floor five level . ( 0.61 cu. m )

4.88

8034

39205.92

... More
providing TMT steel reinforcement bars of ( SAIL,TATA,VIZAG,JSW Steel ltd. )( conforming to I.S 1786 OF 1986 ) for RCC work ( conforming to I.S. 1786 OF 1986) including bending binding & placing in position in all the floors along with the factory made precast concret cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. ( 70.40 kg )

563.2

105

59136

... More
Laterite Masonary Works : Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete for : a)Single Circuit 11kv cable trench (0.2x0.7x1.00)i.e 0.14 per RM , (0.2X0.7X19000 = 2660 Cu.mtr )

2660

2211

5881260

... More
Supply of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable .

1000

2595

2595000

... More
Erection Cost

-

-

-

... More
Earthwork in excavation by mechanical means(hydraulic excavator)/manual means over areas(exceeding 30cm in depth, 1.5 m in width as well as 10sq.m on plan) including disposalof excavated earth lead upto 50M and lift upto 1.5 m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in. a. All kinds of soil

6080

468

2845440

... More
Earthwork in excavation by mechanical means(hydraulic excavator)/manual means over areas(exceeding 30cm in depth, 1.5 m in width as well as 10sq.m on plan) including disposalof excavated earth lead upto 50M and lift upto 1.5 m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in. b. All type of ordinary rock including all types of laterite rock, blasting prohibited.

2280

763

1739640

... More
RCC Hume Pipe 100mm dia with required no. of collars, for road crossing.

500

77

38500

... More
GI Pipe 100 mm, class B for nalla crossing and for cable rising on D.P of DTC

240

92

22080

... More
Supply of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable .

19000

342

6498000

... More
Supply and erection of straight through joint for 300sq.mm cable

74

3713

274762

... More
Supply and laying of underground cable protective covers as per specification as given below : PCC precast cable protective cover of size 480 mm x 250mm x 50mm casted by confined mold vibratory cast of concrete mixM30, having strength of 30N/mm2 at 28 days

40400

60

2424000

... More
Refilling the pipeline /foundation trenches plinth sides, foundation etc. with available excavated eath in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead up to 50 M and all lifts and disposal of surplus earth aas dirrected by Engineer in charge.

6602.5

120

792300

... More
11KV, 3 core, 95sq.mm, AL conductor, XLPE insulated, armoured cable (from the RMU to the transformer)

352

199

70048

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

53

2548

135044

... More
11KV 3 phase outdoor terminating kit to be used with cables - 300sq.mm.

6

2718

16308

... More
11KV 3 phase indoor terminating kit to be used with cables - 95sq.mm.

16

2538

40608

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

16

2648

42368

... More
Cable Route marker

400

256

102400

... More
Earthing with 40mm, 8" long GI pipe with chamber.

50

2444

122200

... More
HDGI flat of size 25mm x 5mm for earthing.

400

48

19200

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxiliary PT as per specification shall be provided in RMU.

8

9720

77760

... More
S.E.T & C Laying of HT/LT UG cables by trenchless technology by adopting horizontal directional drilling (HDD method). The work includes preparation of site, Boring as well as drawing of cable in Normal/hard soil including soft, watery and sandy soil with minimum 8" bore size with HDPE pipe

1000

3600

3600000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.