Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 May 2025
Closing Soon28 May 2025
Tender Amount₹ 40,95,312 
Notes
Download

Costs

  • EMD

    ₹ 81,906
  • Document Cost

    ₹ 2,000
  • Tender Fee

    ₹ 6,000

Summary

1 Work Of Erection Of 100 Kva Dtc At Khalapwaddo Verla Canca Near Shrisha Beauty Parlour Under Section Office Guirim 2 Work Of Erection Of 100kva Dtc At Palyem, Uccassaim, In Order To Release New Conn To Shri Bhanudas Morajkar Section Office Aldona

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and Erection HDGI 'X' arm clamps for RCC Pole 9.00 mtr L.A. as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof

4

266

-

... More
Stay wire 7/10SWG

9.14

141

-

... More
Supply and Erection PVC insulated single core cable 50 mm2 for D.P. earthing

50

135

-

... More
Supply and Erection of DTC Metering Unit

1

25688

-

... More
Modem for Automatic Meter Reading

1

6000

-

... More
Earthing complete comprises of H.D.G.I. Pipe of class B length 2.5 mts , 40mm nominal bore(outside diameter 48.8mm maximum and 47.9mm minimum ,thickness4.0mm and mass of tube plain end 4.37kg/m) conforming to IS1239 Part 1 1990 asamended upto date and hot dip zinc coating shall conform to IS 4736 as ACSR'Weasel' Conductor( quantity as required) , pit filled with homogeneous layer of20 kgs of charcoal, sand and salt as per the drawing No. CEE/E-829

8

2730

-

... More
Supply and Erection of MS Distribution box as per drg No. CEE/E-689 Revision No. 2 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, Other accessories & 200 Amps, Porcelain KitKat Fuse Carrier & Base with extended terminals shall be as per drawing No.CEE/E/543-Rev 4 (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 100 KVA Distribution Transformer centre

1

63140

-

... More
Supply and Erection Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.

2

248

-

... More
Supply and Erection Anticlimbing deviceas per the drawing No. CEE/E-478.

2

962

-

... More
Supply and Erection HDGI DP Structural material shall include :-a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

260

169

-

... More
FRP Fencing Complete with Gate as per specifcation for Distribution Transformer (Size 4MX3MX2M) with Concreting for FRP Fencing supports with plinth (03x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

76667

-

... More
Supply and Stringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/3.10mm aluminium, (nominal aluminium area 50mm)

0.23

60500

-

... More
Supply and Stringing of AAC 'GNAT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/2.21mm aluminium, (nominal aluminium area 25mm2)

0.24

31000

-

... More
Supply and Stringing of Hard drawn stranded aluminium conductor galvanized steel reinforced & conforming to IS:398(Pt-II/96) with amendment no. 1 & 3 & of size 6/2.59 mm aluminium, 1/2.59 mm steel wire "WEASEL"

0.1

40100

-

... More
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. (Sand for cushioning of HT underground cables).(0.6X0.2X170)

21

2170

-

... More
Bricks class design 75 kg/cm2 (1st class wire cut)

875

9

-

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) for foundations of RMU(0.5 cu mt/ Per RMU)

0.5

6635

-

... More
Centering and shuttering including struttings, propping etc and removal of formwork for : Foundations, footings, bases for columns and mass concrete for RMU (3.50sq.mt/RMU).

3.5

407

-

... More
GI Pipe 100 mm , class B

18

811

-

... More
RCC Protective covers of size 600mm length x 250mm width and 50 mm thick capable of bearing load of 135 Kg and covered with earth/sand upto depth of 0.15mts.Confirming to IS 1255-1967 at non-road crossing.

292

127

-

... More
RCC Cable route Markers.

2

528

-

... More
Warning tape.

0.175

15000

-

... More
3 WAY RMU,11 KV,630 A,21 k A 3Sec, SF6 Oudoor RMU-2LBS+1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Electrical closing and tripping along with disconnector and earthing switchs in SF6 and One (1 ) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery Charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consists of VPIS,FPI in LBS Module (N-1) but not less than 1 no's per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery,battery charger shall be provided in RMU.

1

620750

-

... More
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 300 Sq.mm excluding cable end termination.

400

2595

-

... More
H.S.11 KV Termination kit indoor 240/300 XLPE 3 Core

2

8840

-

... More
H.S.11 KV Termination kit indoor 50 to 95 XLPE 3 Core

1

6731

-

... More
H.S.11KV Termination kit outdoor 50 to 95 XLPE 3 Core

1

10152

-

... More
H.S. 11KV straight through joint 3 Core 240 to 400 Sq.mm

2

29559

-

... More
G.I. Flat 25 x 5 mm

15

116

-

... More
COST OF ERECTION (Sub Estimate 1)

-

-

-

... More
Supply and Erection of RCC pole 11 mtr as per the drawing No.CEE/E-698 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

2

9800

-

... More
Supply and Erection of RCC poles 9.00 mtr as per the drawing No.CEE/E-698 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

1

5900

-

... More
Supply and Erection HDGI 2 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/704 as per annexure confirming to IS- 2633/72 or the latest version thereof

5

232

-

... More
Supply and Erection HDGI 4 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/705 as per annexure confirming to IS- 2633/72 or the latest version thereof.

5

261

-

... More
100 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

1

11017

-

... More
Supply and Erection HDGI X arm clamps for RCC Pole 11.00 mtr L.A as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof

6

65

-

... More
Supply and Erection HDGI 'X' arm clamps for RCC Pole 9.00 mtr L.A. as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof

4

45

-

... More
Supply and Erection HDGI stay clamps for RCC Pole 11.00 Mts L.A.as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof

2

98

-

... More
Stay wire 7/10SWG

9.14

62

-

... More
G.I. Stay rod & plate LT/11KV line

2

1779

-

... More
G.I. Turn Buckle with eye bolt 11 KV

2

267

-

... More
Break insulators 8 KV (44KN)

2

97

-

... More
G.I. Nuts & Bolts as per annexure confirming to the IS- 2633/72 or the latest version thereof

11.76

30

-

... More
Supply and Erection PVC insulated single core cable 50 mm2 for D.P. earthing

50

56

-

... More
Supply and Erection 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming toIS-9921 (Part-I to IV) [ 1981 - 85] as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

3971

-

... More
Supply and Erection of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

174

-

... More
11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per drg No. CEE/E-786 as per annexure confirming toI.S. 2062,IS: 1367,IS: 4218,IS: 1363,IS-209 1979 or the latest version thereof

1

3368

-

... More
Supply and Erection of DTC Metering Unit

1

1072

-

... More
Supply of Three Phase 9 KVA Central Control and Monitoring System (CCMS) Strretlight Control Panels on 7.5 mtrs/9 mtrs/11 mtrs Pole and 60 lb/yd, 90 ib/yd rail poles.

1

1900

-

... More
Earthing complete comprises of H.D.G.I. Pipe of class B length 2.5 mts , 40mm nominal bore(outside diameter 48.8mm maximum and 47.9mm minimum ,thickness4.0mm and mass of tube plain end 4.37kg/m) conforming to IS1239 Part 1 1990 asamended upto date and hot dip zinc coating shall conform to IS 4736 as ACSR'Weasel' Conductor( quantity as required) , pit filled with homogeneous layer of20 kgs of charcoal, sand and salt as per the drawing No. CEE/E-829

8

2444

-

... More
Supply and Erection of MS Distribution box as per drg No. CEE/E-689 Revision No. 2 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, Other accessories & 200 Amps, Porcelain KitKat Fuse Carrier & Base with extended terminals shall be as per drawing No.CEE/E/543-Rev 4 (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 100 KVA Distribution Transformer centre

1

8795

-

... More
Supply and Erection Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.

2

57

-

... More
Supply and Erection Anticlimbing deviceas per the drawing No. CEE/E-478.

2

175

-

... More
Supply and Erection HDGI DP Structural material shall include :-a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

260

47

-

... More
Supply and Erection XLPE Single Core unarmoured 300 sq mm,cross linked polyethelene insulated, PVC shealthed 1 core 300 sqmm cable 1.1.KV gradesuitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.

44

218

-

... More
Supply and Erection XLPE cable armoured 3 1/2 CX 120 sq mm, aluminium conductor cable of size 120 sq.mm, 1.1 KV grade as per I.S. standard, with acessories.

36

176

-

... More
FRP Fencing Complete with Gate as per specifcation for Distribution Transformer (Size 4MX3MX2M) with Concreting for FRP Fencing supports with plinth (03x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

35000

-

... More
Supply and Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 300 sq.mm

8

101

-

... More
Supply and Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 120 sq.mm

12

88

-

... More
Supply and Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date as per the drawing No.EE/X/TRN/DRG1/2.

75

104

-

... More
Supply and Erection Metal parts for L.T. Shackle insulators or the Strap type fittings shall consists of a pair of H.D.G.I. straps, 2nos. H.D.G.I. bolts with hexagonal head & nuts, 2 nos. H.D.G.I. spring washers, & helically formed conductor dead-end fittings made of aluminium alloy or aluminium-clad steel conforming to the relevant IS specifications as per the drawing No.EE/X/TRN/DRG1/2.

75

104

-

... More
Supply and Stringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/3.10mm aluminium, (nominal aluminium area 50mm)

0.23

10300

-

... More
Supply and Stringing of AAC 'GNAT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/2.21mm aluminium, (nominal aluminium area 25mm2)

0.24

9100

-

... More
Supply and Stringing of Hard drawn stranded aluminium conductor galvanized steel reinforced & conforming to IS:398(Pt-II/96) with amendment no. 1 & 3 & of size 6/2.59 mm aluminium, 1/2.59 mm steel wire "WEASEL"

0.1

11000

-

... More
Removing and Restringing AAC conductor 'ANT'

1.02

15450

-

... More
Removing and Restringing AAC conductor 'GNAT'

1.02

13650

-

... More
Removing RCC poles 7.5 mtr

1

2600

-

... More
Removing HDGI 2 pin 'X' arm of 75 x 40 Channel

2

116

-

... More
Removing HDGI 4 pin 'X' arm of 75 x 40 Channel

2

130

-

... More
Removing L.T. Shackle insulators

5

-

-

... More
Removing Metal parts for L.T. Shackle insulators

5

-

-

... More
Removing L.T. Pin Insulators

20

-

-

... More
Removing G.I. Pin for L.T.Pin Insulators

20

-

-

... More
Laying of Underground Cable

1

-

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :Dimensions for excavation are 0.6X1.1X15+(0.60 Cu.mt per RMU)

116.1

468

-

... More
Refilling the pipeline/foundation trenches plinth side,foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge(0.9X0.6X170)+(0.26 cu.mts per RMU)

94.76

120

-

... More
Disposal of surplus earth

21.34

125

-

... More
GI Pipe 100 mm , class B

18

92

-

... More
RCC Protective covers of size 600mm length x 250mm width and 50 mm thick capable of bearing load of 135 Kg and covered with earth/sand upto depth of 0.15mts.Confirming to IS 1255-1967 at non-road crossing.

292

84

-

... More
RCC Cable route Markers.

2

256

-

... More
Reinstatement of roads

0.175

818943

-

... More
3 WAY RMU,11 KV,630 A,21 k A 3Sec, SF6 Oudoor RMU-2LBS+1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Electrical closing and tripping along with disconnector and earthing switchs in SF6 and One (1 ) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery Charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consists of VPIS,FPI in LBS Module (N-1) but not less than 1 no's per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery,battery charger shall be provided in RMU.

1

9720

-

... More
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 300 Sq.mm excluding cable end termination.

400

342

-

... More
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 95 Sq.mm excluding cable end termination.

25

199

-

... More
H.S.11 KV Termination kit indoor 240/300 XLPE 3 Core

2

2548

-

... More
H.S.11 KV Termination kit indoor 50 to 95 XLPE 3 Core

1

2538

-

... More
H.S.11KV Termination kit outdoor 50 to 95 XLPE 3 Core

1

2648

-

... More
H.S. 11KV straight through joint 3 Core 240 to 400 Sq.mm

2

3713

-

... More
G.I. Flat 25 x 5 mm

15

48

-

... More
COST OF MATERIAL (Sub Estimate 2)

-

-

-

... More
ACSR conductor 'Weasel' for Jumpering and For Earthing

0.08

40100

-

... More
Supply and Erection of MS Distribution box as per drg No. CEE/E-689 Revision No. 2 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, Other accessories & 200 Amps, Porcelain KitKat Fuse Carrier & Base with extended terminals shall be as per drawing No.CEE/E/543-Rev 4 (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 100 KVA Distribution Transformer centre

1

63140

-

... More
Supply and Erection of DTC Metering Unit

1

25688

-

... More
Modem for Automatic Meter Reading

1

6000

-

... More
Supply and Erection Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.

2

248

-

... More
Earthing complete comprises of H.D.G.I. Pipe of class B length 2.5 mts , 40mm nominal bore(outside diameter 48.8mm maximum and 47.9mm minimum ,thickness4.0mm and mass of tube plain end 4.37kg/m) conforming to IS1239 Part 1 1990 asamended upto date and hot dip zinc coating shall conform to IS 4736 as ACSR'Weasel' Conductor( quantity as required) , pit filled with homogeneous layer of20 kgs of charcoal, sand and salt as per the drawing No. CEE/E-829

8

2730

-

... More
Supply and Erection PVC insulated single core cable 50 mm2 for D.P. earthing

50

135

-

... More
3 WAY RMU,11 KV,630 A,21 k A 3Sec, SF6 Oudoor RMU-2LBS+1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Electrical closing and tripping along with disconnector and earthing switchs in SF6 and One (1 ) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery Charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consists of VPIS,FPI in LBS Module (N-1) but not less than 1 no's per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery,battery charger shall be provided in RMU.

1

620750

-

... More
Numbering of 11KV RMU

3

104

-

... More
G.I. Flat 25 x 5 mm for RMU earthing

10

116

-

... More
H.S.11 KV Termination kit indoor 50 to 95 XLPE 3 Core

1

6731

-

... More
H.S.11KV Termination kit outdoor 50 to 95 XLPE 3 Core

1

10152

-

... More
Supply, Erection, Testing & Commissioning of Heat shrinkable 11 KV Termination kit Indoor 3 core 300 sqmm XLPE (For RMU)

2

8840

-

... More
Supply & erection of 11 KV straight throgh jointing kit suitable for 300 sq mm XLPE cable

1

29559

-

... More
FRP Fencing Complete with Gate as per specifcation for Distribution Transformer (Size 3MX3MX2M) with Concreting for FRP Fencing supports with plinth (03x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

71167

-

... More
PLINTH FOR RMU

1

-

-

... More
Centaring and shuttering including struttings,propping etc. and removal of formwork for foundations,footings, bases for coloumns and mass concrete. (for RMU 4.25 sq.mtr)

11.87

-

-

... More
Providing and laying in position cement concrete 1:2:4 ( 1 Cement : 2 coarse sand : 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering, shuttering and finishing: ( for RMU 1.2cu.mtrs)

3.58

-

-

... More
12mm cement plaster 1:4(1 cement:4 fine sand) (for RMU 2.8sq.mtrs)

11.41

-

-

... More
LAYING OF UG CABLE

1

-

-

... More
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. (Sand for cushioning of HT underground cables).(0.6X0.15X210)

9.3

2170

-

... More
Supply and laying of UG Cable protective covers of size 480mm long x 250mm width and 50mm thick

251

135

-

... More
RCC Cable route Markers.

5

528

-

... More
Warning tape.

0.15

15000

-

... More
LT WORK

1

-

-

... More
Supply and Erection HDGI 4 pin 'X' arm of 75 x 40 Channel as per the drawing

6

1109

-

... More
HDGI 'X' arm clamps for RCC Pole 9.00 mtr L.A.

9

266

-

... More
Supply and Erection of HDG.I. stay wire 7/10 SWG

3.74

141

-

... More
Supply and Stringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor

0.08

60500

-

... More
Supply and Stringing of AAC 'GNAT' Conductor, hard drawn

0.06

31000

-

... More
COST OF ERECTION (Sub Estimate 2)

-

-

-

... More
G.I. Nuts & Bolts as per annexure confirming to the IS- 2633/72 or the latest version thereof

4.014

30

-

... More
100 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

1

11017

-

... More
ACSR conductor 'Weasel' for Jumpering and For Earthing

0.08

11000

-

... More
Supply and Erection of MS Distribution box as per drg No. CEE/E-689 Revision No. 2 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, Other accessories & 200 Amps, Porcelain KitKat Fuse Carrier & Base with extended terminals shall be as per drawing No.CEE/E/543-Rev 4 (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 100 KVA Distribution Transformer centre

1

8795

-

... More
Supply and Erection of DTC Metering Unit

1

1072

-

... More
Modem for Automatic Meter Reading

1

-

-

... More
Supply and Erection Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.

2

57

-

... More
Earthing complete comprises of H.D.G.I. Pipe of class B length 2.5 mts , 40mm nominal bore(outside diameter 48.8mm maximum and 47.9mm minimum ,thickness4.0mm and mass of tube plain end 4.37kg/m) conforming to IS1239 Part 1 1990 asamended upto date and hot dip zinc coating shall conform to IS 4736 as ACSR'Weasel' Conductor( quantity as required) , pit filled with homogeneous layer of20 kgs of charcoal, sand and salt as per the drawing No. CEE/E-829

8

2444

-

... More
Supply and Erection PVC insulated single core cable 50 mm2 for D.P. earthing

50

56

-

... More
Supply and Erection XLPE Single Core unarmoured 300 sq mm,cross linked polyethelene insulated, PVC shealthed 1 core 300 sqmm cable 1.1.KV gradesuitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date. (From transformer to DB)

40

218

-

... More
Supply and Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 300 sq.mm

8

101

-

... More
Supply and Erection XLPE cable armoured 3 1/2 CX 185 sq mm,cross linked polyethelene insulated, PVC shealthed 1 core 120 sqmm cable 1.1.KV gradesuitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.(LT Feeder Cable )

300

228

-

... More
Supply and Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 185 sq.mm

12

95

-

... More
3 WAY RMU,11 KV,630 A,21 k A 3Sec, SF6 Oudoor RMU-2LBS+1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Electrical closing and tripping along with disconnector and earthing switchs in SF6 and One (1 ) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery Charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consists of VPIS,FPI in LBS Module (N-1) but not less than 1 no's per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery,battery charger shall be provided in RMU.

1

9720

-

... More
Numbering of 11KV RMU

3

-

-

... More
G.I. Flat 25 x 5 mm for RMU earthing

10

48

-

... More
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 95 Sq.mm excluding cable end termination.(From RMU to Transformer )

90

199

-

... More
H.S.11 KV Termination kit indoor 50 to 95 XLPE 3 Core

1

2538

-

... More
H.S.11KV Termination kit outdoor 50 to 95 XLPE 3 Core

1

2648

-

... More
Supply,Erection,Testing & Comissioning of 11KV, 3Core 300 sq.mm A2XFY Al.armoured XLPE cable through conventional open trenching method in any type of soil including hard laterite.

10

342

-

... More
Supply, Erection, Testing & Commissioning of Heat shrinkable 11 KV Termination kit Indoor 3 core 300 sqmm XLPE (For RMU)

2

2548

-

... More
Supply & erection of 11 KV straight throgh jointing kit suitable for 300 sq mm XLPE cable

1

3713

-

... More
FRP Fencing Complete with Gate as per specifcation for Distribution Transformer (Size 3MX3MX2M) with Concreting for FRP Fencing supports with plinth (03x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

33667

-

... More
Centaring and shuttering including struttings,propping etc. and removal of formwork for foundations,footings, bases for coloumns and mass concrete. (for RMU 4.25 sq.mtr)

11.87

407

-

... More
Providing and laying in position cement concrete 1:2:4 ( 1 Cement : 2 coarse sand : 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering, shuttering and finishing: ( for RMU 1.2cu.mtrs)

3.58

6635

-

... More
12mm cement plaster 1:4(1 cement:4 fine sand) (for RMU 2.8sq.mtrs)

11.41

223

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :Dimensions for excavation are (0.6X1.1X30) for cable and (0.6 for RMU)

68.8

763

-

... More
Refilling the pipeline/foundation trenches plinth side,foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M (0.6X0.9X30) for Cable and (0.26 for RMU)

56.06

120

-

... More
Disposal of surplus earth (Excavation-Refilling)

12.74

125

-

... More
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. (Sand for cushioning of HT underground cables).(0.6X0.15X210)

9.3

-

-

... More
Supply and laying of UG Cable protective covers of size 480mm long x 250mm width and 50mm thick

251

60

-

... More
RCC Cable route Markers.

5

256

-

... More
Reinstatement of roads

0.01

818943

-

... More
RCC poles 9.00 mtr

2

5900

-

... More
Supply and Erection HDGI 2 pin 'X' arm of 75 x 40 Channel as per the drawing

3

232

-

... More
Supply and Erection HDGI 4 pin 'X' arm of 75 x 40 Channel as per the drawing

6

261

-

... More
HDGI 'X' arm clamps for RCC Pole 9.00 mtr L.A.

9

45

-

... More
HDGI stay clamps for RCC Pole 9 mtr L.A.

1

79

-

... More
Supply and Erection of HDG.I. stay wire 7/10 SWG

3.74

62

-

... More
Supply and Erection of H.D.G.I. stay rod of 1200mm long and 16mm dia with an eye band

1

1779

-

... More
Supply and Erection G.I. Turn Buckle with eye bolt 11 KV as per the drawing No. CEE/E-466

1

267

-

... More
Supply and Erection of Break insulators 8 KV (44KN) as per the drawing

1

97

-

... More
Supply and Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm

55

104

-

... More
Supply and Erection Metal parts for L.T. Shackle insulators

55

104

-

... More
Supply and Stringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor

0.08

10300

-

... More
Supply and Stringing of AAC 'GNAT' Conductor, hard drawn

0.06

9100

-

... More
Removing and Restringing AAC conductor 'ANT'

0.72

15450

-

... More
Removing and Restringing AAC conductor 'GNAT'

0.48

13650

-

... More
Removing RCC poles 7.5 mtr

1

2600

-

... More
Removing HDGI 2 pin 'X' arm of 75 x 40 Channel

1

-

-

... More
Removing HDGI 4 pin 'X' arm of 75 x 40 Channel

2

-

-

... More
Removing L.T. Pin Insulators

9

-

-

... More
Removing G.I. Pin for L.T.Pin Insulators

9

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.