Website Tenders
Website Tenders
DEPT OF THE NAVY USA Tender
Others
Corrigendum : Closing Date Modified
United States
Description: Contact Information|4|n742.10|wv1|(717) 605-4056|madison.m.gray4.civ@us.navy.mil|
item Unique Identification And Valuation (jan 2023)|19||||||||||||||||||||
higher-level Contract Quality Requirement (navicp Review Feb 1991)(feb 1999)|1|iso9001|
inspection Of Supplies--fixed-price (aug 1996)|2|||
inspection/acceptance Point|6||dcma Nseo S4306a||||dcma Nseo S4306a|
wide Area Workflow Payment Instructions (jan 2023)|16|material - Invoice & Receiving Report (combo) Certifications - Stand-alone Receiving Report|n/a|tbd|n00104|tbd|material - S4306a; Certifications - N39040|n50286|tbd|136|n/a|n/a|certifications - N39040|n/a|n/a|s
ee Dd Form 1423|port_ptnh_wawf_notification@navy.mil|
navy Use Of Abilityone Support Contractor - Release Of Offeror Information (3-18))|1||
equal Opportunity (sep 2016)|2|||
warranty Of Supplies Of A Noncomplex Nature (june 2003)|6|one Year From Date Of Delivery|one Year From Date Of Delivery|||||
warranty Of Data--basic (mar 2014)|2|||
buy American --free Trade Agreements--balance Of Payments Program - Basic (feb2024))|11||||||||||||
alternate A, Annual Representations And Certifications (nov 2023)|13||||||||||||||
buy American-free Trade Agreements-balance Of Payments Program Certificate-basic (feb 2024))|5||||||
buy American-balance Of Payments Program Certificate-basic (feb 2024)|1||
annual Representations And Certifications (feb 2024)|13|332911|750 (# Of Employees)||||||||||||
notice Of Priority Rating For National Defense, Emergency Perpardeness, And Enrgy Progam Use (april 2008))|2|x||
this Amendment Shall Be Issued To Provide A Response To The Bidder's Notes Submitted With Moog's Quote Q13082.
moog Email Dated 20 May 2024 From Mhairi Metzel Submitted Moog Quotation Q13082for The Subject Solicitation. Moog Quotation Q13082 Included The Following Statements, And Navsup Wss Requested That Navsealogcen Address The Exceptions:
"moog Requests Flow Down Of Ndt Requirements Per Navsea Directive In Letter 9556 Ser 05z/478."
in Response, Navsealogcen Stated That Non-destructive Testing (ndt) Conducted In Accordance With Navsea Letter 9556 Ser 05z/478 Dated 13 August 2020 Is Acceptable For The Subject Contract.
"moog Will Provide Item No. 3 - Rack On Drawing Number 15097-37100 Using Material In Accordance With Aisi 4340 Steel As Opposed To Aisi 4140 Steel. Due To The Heat Treating Strength Requirements, It Is Very Difficult To Procure 4140 Material With The Required
material Strengths; Therefore, Moog Will Be Using 4340 Material, Which Is Readily Available From Suppliers."
in Response, Navsealogcen Stated That, Provided The Mechanical Properties Are Equivalent To Aisi 4140, Rack, Item 3 Of Flo-tork Drawing 15097-37100 Revision C Supplied As Material Specification Aisi 4340 In Lieu Of Aisi 4140 Is Acceptable For The Subject
solicitation.
"moog Will Provide Item 35, Set Screw, In Accordance With Class 303 Instead Of Class 304. Material Spec Qq-s-764 Does Not Have Class 304 As An Option."
in Response, Navsealogcen Stated That Supplying The Set Screw, Item 35 Of Flo-tork Drawing 15097-37100 Revision C, With Material In Accordance With Class 303, Condition A Per Qq-s-764, In Lieu Of Class 304 As Required By The Drawing, Is Acceptable For The Subject
solicitation, Subsequent Contract, And Future Procurements.
"reference Previously Approved For Navsup Contract N00104-21-p-fb32. Moog Is Requesting To Use Acoustic Test Criteria To The Virginia Class Equivalent Model 15094a (drawing 15094-41655), As The Seawolf Criteria Is Difficult Or Impossible To Meet Given The Energy
absorbers Have Been Removed From This Actuator Design Due To Break Down Of The Polyurethane Material On Board The Submarines. The Removal Was Done In 2011 As Part Of Revision C Of Drawing 15097-37100. Moog Manufactured This Same Actuator Model Back In 2013 For E
electric Boat (eb), And The Same Request Was Made. The Following Waiver Approval Was Given By Eb. "electric Boat Finds Acoustic Testing Virginia Class Acceptance Criteria Technically Acceptable. Flo-tork Actuator 15097-37100 Is Used As Td-785, Eav Flood & Drain
hull Valve For The Brizo Program." This Was On Electric Boat Po # Ppx171 Issued To Moog Flo-tork."
in Response, Navsealogcen Stated That The Request To Test The Subject Hydraulic Actuator To Virginia Class Vibration Requirements For The Subject Solicitation Is Approved For The Subject Solicitation And Subsequent Contract. Structure Borne Vibration Testing Is To
Be Performed To Virginia Class Acceptance Criteria In Accordance With Flo-tork Drawing 15094-41655 Revision B.
\
1. All Contractual Documents (i.e., Contracts, Purchase Orders, Task Orders, Delivery Orders, And Modifications) Related To The Instant Procurement Are Considered To Be "issued" By The Government When Copies Are Either In The Mail, Transmitted By Facsimile, Or
sent By Other Electronic Methods, Such As Email. The Government's Acceptance Of The Contract Proposal Constitutes Bilateral Agreement To "issue" Contractual Documents As Detailed Herein.
2. The Following Proposed Delivery Schedule Applies:
submission Of Certification Data Cdrls Will Be On Or Before 20 Days Prior To Scheduled Delivery. Pnsy Review/acceptance Of Certification Cdrls 6 Working Days After Receipt Of Certification Dd 1423 Cdrls.
final Delivery Of Material Shall Be On Or Before 300 Days After The Effective Date Of The Contract.
3. Any Contract/order Awarded As A Result Of This Solicitation Will Be A "dx" Rated Order Certified For National Defense Use Under The Defense Priorities And Allocations System (dpas). See Far Clause 52.211-14, Notice Of Priority Rating For National Defense,
emergency Preparedness, And Energy Program Use.
4. The Resultant Award Of This Solicitation Will Be Issued Bilaterally, Requiring The Contractor's Written Acceptance Prior To Execution.
5. Dd 1423 Data Item A001 May Be Waived If Already On File At Navsup Wss Mechanicsburg.
\
1. Scope
1.1 The Material Covered In This Contract/purchase Order Will Be Used In A Crucial Shipboard System. The Use Of Incorrect Or Defective Material Would Create A High Probability Of Failure Resulting In Serious Personnel Injury, Loss Of Life, Loss Of Vital
shipboard Systems, Or Loss Of The Ship Itself. Therefore, The Material Has Been Designated As Special Emphasis Subsafe/non-level I Material And Special Control Procedures Are Invoked To Ensure Receipt Of Correct Material.
2. Applicable Documents
2.1 Order Of Precedence - In The Event Of A Conflict Between The Text Of This Contract/purchase Order And The References And/or Drawings Cited Herein, The Text Of This Contract/purchase Order Must Take Precedence. Nothing In This Contract/purchase Order,
however, Must Supersede Applicable Laws And Regulations Unless A Specific Exemption Has Been Obtained.
2.2 Applicable Documents - The Document(s) Listed Below Form A Part Of This Contract/purchase Order Including Modifications Or Exclusions.
2.2.1 Specification Revisions - The Specification Revisions Listed Under "documents References" Below Are The Preferred Revision. Older And/or Newer R Evisions Are Acceptable When Listed Within Contract Support Library Reference Number Csd155 In Ecds (electric
contractor Data Submission) At: Ht Tps://register.nslc.navy.mil/. This Is To Allow Contractors To Use Certain Acceptable Older Specification Revisions To Purge Their Existing Stock Of Material Certified To Those Older Revisions Or To Use Newer Specification
revisions When Material Is Certified To Newly Released Revisions,without Requiring The Submittal Of Waiver/deviation Requests For Each Specification Revision On Every Contract. Revisions Of Specifications Reflecting Editorial And/or Re-approval (e.g. E2009,
r2014, Etc.) Are Considered Inconsequential, But Are Acceptable When Their Revisions Are Listedwithin Csd155 Or Elsewhere Within This Contract.
2.2.2 Test/inspection Certifications - To Allow Contractors To Use Existing Stock Of Material Previously Tested With Ndt Specification Revisions That Are Technically Acceptable While Minimizing The Submittal Of Waivers/deviations, The Following
test/inspection Specification Revisions Are Acceptable In Lieu Of Their Preferred Current Revisions (where Applicable) Listed Under "document References" Below When They Were The Current Revision As Of The Date Of Ndt Certification.
mil-std-1949 Original, Revision A, A Chg Not 2
mil-i-6868 Rev. E, Revision E Amendment 1, Revision E Amendment 2
astm-e1417 1999, 2011
sae-ams-std-2154 2005, 2010
2.2.3 The Documents And Drawings Listed Below Under Drawing No. Are Not Provided With This Contract/purchase Order.
drawing No Cage Rev Distr Cd
;15097-37100 07270 C D
2.2.4 "document References" Listed Below Must Be Obtained By The Contractor. Ordering Information Is Included As An Attachment To This Contract/purchase Order.
document Ref Data=ansi/asq Z1.4 | | | |080101|a| | |
document Ref Data=mil-std-792 | | |f |060519|a| | |
document Ref Data=astm-e1417 | | | |160615|a| | |
document Ref Data=astm-e1444 | | | |160601|a| | |
document Ref Data=mil-i-6868 | | |e |800606|a|3 | |
document Ref Data=iso_9001 | | | |081115|a| | |
document Ref Data=iso10012 | | | |030415|a| | |
document Ref Data=iso/iec 17025 | | | |050515|a| | |
document Ref Data=mil-i-45208 | | |a |810724|a|1 | |
document Ref Data=mil-std-45662 | | |a |880801|a| | |
document Ref Data=sae Ams-std-2154 | | |d |200401|a| | |
document Ref Data=ansi/ncsl Z540.3 | | | |130326|a| | |
document Ref Data=0900-lp-001-7000 | | | |810101|c| |01|
document Ref Data=s9074-aq-gib-010/248 | | |1 |191112|a| | |
document Ref Data=t9074-as-gib-010/271 | | |1 |140911|a| | |
document Ref Data=s9074-ar-gib-010a/278 (chg A) | | | |130214|a| | |
3. Requirements
3.1 Design, Manufacture, And Performance - Except As Modified Herein, The Item Furnished Under This Contract/purchase Order Must Meet The Design, Manufacture, And Performance Requirements Specified On Cage ;07270;
drawing ;15097-37100; .
3.2 A Certificate Of Tests Is Required For Non-destructive, Hydrostatic, And Operational Testing As Required By The Assembly Drawing And The Maintenance Standard, When Invoked. Non-destructive Testing Must Be In Accordance With T9074-as-gib-010/271.
3.3 Certificate Of Compliance - (special Emphasis Subsafe/non-level I Material) - The Contractor Must Prepare And Submit A Certificate Of Compliance Traceable To Each Serialized Component, Certifying That The Components Furnished Under This Contract Comply
with The Requirements Of The Procurement Document, Including Any/all Invoked Specifications And Drawings.
3.4 Each Component Must Be Assigned A Unique Serial Number. The Component Must Be Marked With This Serial Number On The Major Piece Part Of The Assembly. (e.g. Body, Casing) Serial Number Marking Must Be Permanently Applied In Accordance With Mil-std-792.
this Serial Number Must Also Be Annotated On The C Of C To Provide Positive Traceability.
3.4.1 In The Event Of Refurbishment, If An Existing Readable Serial Number Is Found On The Component, A Suffix Must Be Applied To Ensure The Final Serial Number Is Unique.
3.5 Welding Or Brazing - When Welding, Brazing, And Allied Processes Are Required, As Invoked By Section C Paragraph 3 Requirements, They Must Be In Accordance With S9074-ar-gib-010a/278, 0900-lp-001-7000 For Brazing Of Piping And Pressure Vessel Applications,
or S9074-aq-gib-010/248 For Brazing Of Other Applications. For All Production And Repair Welding And Brazing Personnel And Procedures Must Be Qualified Under S9074-aq-gib-010/248 Or 0900-lp-001-7000, As Applicable. Procedures And Qualification Data Must Be
submitted For Review And Approval Prior To Performing Any Welding Or Brazing.
3.6 Configuration Control - The Contractor Must Maintain The Total Equipment Baseline Configuration. For Items Of Proprietary Design, Contractor Drawings Showing The Latest Assembly Configuration Must Be Provided To The Government In Electronic (c4) Format.
definitions Are Provided Elsewhere In The Contract/purchase Order.
3.6.1 Waivers/deviations - All Waivers And Deviations, Regardless Of Significance Or Classification Require Review And Approval By The Contracting Officer. Waivers And Deviations Must Be Designated As Critical, Major, Or Minor. The Contractor Must Provide A
copy Of This Request To The Qar. Requests Must Include The Information Listed Below.
A. A Complete Description Of The Contract Requirement Affected
And The Nature Of The Waiver/deviation (non-conformance),
Including A Classification Of Critical, Major, Or Minor.
B. Number Of Units (and Serial/lot Numbers) To Be Delivered In This
Configuration.
C. Any Impacts To Logistics Support Elements (such As Software,
Manuals, Spares, Tools, And Similar) Being Utilized By Government
Personnel Or Impacts To The Operational Use Of The Product.
D. Information About Remedial Action Being Taken To Prevent Reoccurrence
Of The Non-conformance.
3.6.2 All Requests For Waivers/deviations On Navsup-wss Contracts Must Be Submitted To The Navsup Wss Contracting Specialist Via Email.
3.6.3 Ecps - The Government Will Maintain Configuration Control And Change Authority For All Modifications Or Changes Affecting Form, Fit, Function, Or Interface Parameters Of The Equipment And Its Sub-assemblies. The Contractor Must Submit An Engineering
change Proposal (ecp) For Any Class I Or Ii Changes That Impact The Equipment Covered By This Contract. Ecps Must Be Prepared In Contractor Format, And Must Include The Following Information:
A. The Change Priority, Change Classification (class I Or Class Ii),
And Change Justification.
B. A Complete Description Of The Change To Be Made And The Need For
That Change.
C. A Complete Listing Of Other Configuration Items Impacted By The
Proposed Change And A Description Of The Impact On Those Cis.
D. Proposed Changes To Documents Controlled By The Government.
E. Proposed Serial/lot Number Effectivities Of Units To Be
Produced In, Or Retrofitted To, The Proposed Configuration.
F. Recommendations About The Way A Retrofit Should Be Accomplished.
G. Impacts To Any Logistics Support Elements (such As Software,
Manuals, Spares, Tools, And Similar) Being Utilized By Government
Personnel In Support Of The Product.
H. Impacts To The Operational Use Of The Product.
I. Complete Estimated Life-cycle Cost Impact Of The Proposed Change.
J. Milestones Relating To The Processing And Implementation Of The
Engineering Change.
3.7 Mercury Free - Mercury And Mercury Containing Compounds Must Not Be Intentionally Added Or Come In Direct Contact With Hardware Or Supplies Furnished Under This Contract. Mercury Contamination Of The Material Will Be Cause For Rejection.
^ Quality Assurance Requirements ^
3.8 Quality System Requirements - The Contractor Furnishing Items Under This Contract/purchase Order Must Provide And Maintain A Quality System In Accordance With Iso-9001 As Amplified Or Modified Herein, With The Calibration System Requirements Of Iso-10012
or Ansi-z540.3 With Iso-17025. A Quality System In Accordance With Mil-i-45208, With The Calibration System Requirements Of Mil-std-45662, Is Acceptable As An Alternate.
3.8.1 The Contractor's Quality System And Products Supplied Under The System Are Subject To Evaluation, Verification Inspection, And Acceptance/nonacceptance By The Government Representative To Determine The System's Effectiveness In Meeting The Quality
requirements Established In The Contract/purchase Order.
3.8.2 The Contractor's Quality System Must Be Documented And Must Be Available For Review By The Contracting Officer Or His Representative Prior To Initiation Of Production And Throughout The Life Of The Contract. The Prime Contractor Must, Upon
notification, Make His Facilities Available For Audit By The Contracting Officer Or His Authorized Representative.
3.8.3 See Cdrl Di-qcic-81110 (inspection System Procedures) - All Suppliers Of Subsafe/non-level (q5) Material Are Required To Submit A Copy Of Their Current Documented Quality System Procedures To The Procurement Contracting Officer (pco) Prior To Award Of
any Contract/purchase Order. Suppliers That Have A Copy Of Their Current Quality System Procedures On File At The Procuring Activity May Request The Pco Waive This Requirement.
3.8.4 This Contract Provides For The Performance Of Government Quality Assurance At Source. The Place Or Places Of Performance May Not Be Changed Without The Authorization Of The Procurement Contracting Officer. Upon Receipt Of This Order, Promptly Notify
the Government Representative Who Normally Services Your Plant So That Appropriate Planning For Government Inspection Can Be Accomplished. If You Do Not Have An Assigned Government Representative, Notify The Nearest Defense Contract Management Agency (dcma)
office. In The Event That A Local Government Representative Or Dcma Office Cannot Be Located, Our Purchasing Agent Should Be Notified Immediately.
3.8.5 Any Changes Made By The Contractor To A Qualified Quality System Will Require Concurrence By The Government Quality Assurance Representative Prior To Adoption.
3.9 Contractor Inspection Requirements - The Contractor Must Maintain Adequate Records Of All Inspections And Tests. The Records Must Indicate The Nature And Number Of Observations Made, The Number And Type Of Deficiencies Found, The Quantities Approved And
rejected And The Nature Of Corrective Action Taken As Appropriate.
3.9.1 The Supplier's Gages, Measuring And Test Equipment Must Be Made Available For Use By The Government Representative When Required To Determine Conformance With Contract Requirements. When Conditions Warrant, The Supplier's Personnel Must Be Made
available For Operations Of Such Devices And For Verification Of Their Accuracy And Condition.
3.9.2 All Documents And Reference Data Applicable To This Contract Must Be Available For Review By The Government Representative. Copies Of Documents Required For Government Inspection Purposes Must Be Furnished In Accordance With The Instructions Provided
by The Government Representative.
3.10 Responsibility For Inspection - Unless Otherwise Specified In The Contract/purchase Order, The Contractor Is Responsible For The Performance Of All Inspection Requirements As Specified Herein. Except As Otherwise Specified In The Contract/purchase Order,
the Contractor May Use His Own Or Any Other Facilities Suitable For The Performance Of The Inspection Requirements Specified Herein, Unless Disapproved By The Government. The Government Reserves The Right To Perform Any Of The Inspections Set Forth In The
specification Where Such Inspections Are Deemed Necessary To Assure Supplies And Services Conform To Prescribed Requirements.
3.11 Subcontractor Inspection Requirements - The Government Has The Right To Inspect At Source, Any Supplies Or Services That Were Not Manufactured Or Performed Within The Contractor's Facility. Such Inspection Can Only Be Requested By Or Under Authorization
of The Government Representative. Any Purchasing Documents To A Subcontractor Must Cite The Applicable Portions Of The Contractually Invoked Quality System (e.g. Calibration Requirements), Plus Any Product Requirements To Apply To The Supplies Being Purchased.
when The Government Elects To Perform Source Inspection At The Subcontractor's Facility, Applicable Purchase Documents Must Be Annotated With The Following Statement: "a Government Inspection Is Required Prior To Shipment From Your Plant. Upon Receipt Of This
order, Promptly Notify The Government Representative Who Normally Services Your Plant So That Appropriate Planning For Government Inspection Can Be Accomplished. If You Do Not Have An Assigned Government Representative, Notify The Nearest Defense Contract
management Agency (dcma) Office. In The Event That A Local Government Representative Or Dcma Office Cannot Be Located, Our Purchasing Agent Should Be Notified Immediately."
3.12 Final Inspection - The Following Inspection Must Be Performed Prior To Shipping Material.
3.12.1 Material Sampling - Material Must Be Inspected For Form, Fit, And Function. Lot Acceptance Must Be Based On Zero Defects And Lot Rejection Based On One Defect. The Sample Size Must Be In Accordance With The Sampling Plan(s) In The Applicable Military
specification Or Standard, Federal Specification Or Standard, Or Drawing To Which The Material Was Manufactured. In The Absence Of Such Sampling Plans, Sampling Inspection Must Be Per Ansi/asq-z1.4, General Inspection Level Ii (for Sample Size Selection Code),
table Iia (for Sample Size).
small Lot Sizes - For Lot Sizes Of Fifty Or Less, The Minimum Sample Size Must Be Eight Units. For Lot Sizes Of Eight Or Less, The Sample Size Must Be One Hundred Percent Of The Lot.
3.12.2 Material Must Be Inspected For Form, Fit, And Function In Accordance With The Sampling Plan(s) In The Applicable Military Specification Or Standard, Federal Specification Or Standard, Or Drawing To Which The Material Was Manufactured. The Absence Of
such Sampling Plans, Sampling Inspection Must Be Per Ansi/asq-z1.4, General Inspection Level Ii (for Sample Size Selection Code), Table Iia (for Sample Size) With Lot Acceptance Based On Zero Defects And Lot Rejection Based On One Defect. Due To The High
consumer Risk Associated With Small Sample Sizes, The Minimum Sample Size Must Be Eight Units (for Lot Sizes Of Fifty Or Less) Or One Hundred Percent (for Lot Sizes Of Eight Or Less).
3.12.3 The Manufacturer May Elect To Use Statistical Process Control (spc) To Assure Product Quality In Lieu Of The Above Attribute Sampling Plan, Provided That The Spc Methodology/system Used Provides Acceptable Products To The Government. However, The
government/navy Receipt Inspection Activity May Perform Their Acceptance Inspection Of The Material Using The Attribute Sampling Plan Outlined Above.
3.13 See Cdrl Di-misc-80678 (special Emphasis Subsafe/non-level I Material C Of C) - The Certificate Of Compliance Must Contain:
1. Contractor's Name, Address, Phone Number And Date
2. The Contract Issuing Agency's Contract/purchase Order Number
3. The National Stock Number (nsn)
4. Government Nomenclature (noun Name) Of The Item Purchased
5. Contractor's Nomenclature (noun Name) Of Item Purchased
6. Component Serial Number
7. Contractor's Or Authorized Personnel's Signature
8. A Statement To The Effect That All Items Furnished On This Contract Are In Full Compliance With The Specifications And Requirements. Submission Must Be In Accordance With The Contract Data Requirements List (dd Form 1423).
3.14 See Cdrl Di-misc-80678 (special Emphasis Ss-non-li Hydrostatic, Ndt Per T9074-as-gib-010/271, And Operational Testing) - The Certificate Of Tests (c Of T) Shall Contain:
1. Contractor's Name, Address, Phone Number And Date
2. The Contract Issuing Agency's Contract/purchase Order Number
3. The National Stock Number (nsn)
4. Government Nomenclature (noun Name) Of The Item Purchased
5. Contractor's Nomenclature (noun Name) Of Item Purchased
6. Component Serial Number
7. Contractor's Or Authorized Personnel's Signature
8. A Statement Of Tests Performed Listing The Pieces Tested.
A. The Standard/specification To Which Testing Was Performed.
B. The Revision Of The Standard/specification.
C. The Acceptance Criteria Used.
9. Test Procedure Numbers May Also Be Referenced On Test Reports.
10. Test Reports On Welds Shall Be Identified To Weld Joint And Layer.
11. When Hydrostatic Tests, Operational Testing, Or Ndt Is Not Required Per The Applicable Drawing, The C Of T Shall So State. (i.e. "no Ndt Is Required Per The Applicable Drawing.")
3.15 See Cdrls Di-misc-80875 (welding Procedures) And Di-misc-80876 (weld Procedure Qualification Data) - When Production Or Repair Welding Or Brazing Is Required, The Applicable Welding/brazing Procedure(s) And Qualification Data Must Be Submitted For
review And Approval.
note: These Requirements Do Not Apply To Tack/spot Welds.
3.15.1 Approval Of The Contractor's Qualification Data Must Be Obtained Prior To Performing Any Welding (production Or Repair). Welding/brazing Qualification Must Be In Accordance With S9047-aq-gib-010/248. Applications For Which Commercial Welding Is
allowed Must Have Procedures And Qualification Data Which Meet All Applicable Requirements Of The Specification (aws, Asme, Etc.). The Procedure And Qualification Data Must State The Specification And Its Revision That Is Being Used. Suppliers That Are
unsure If Commercial Welding Is Allowed For A Particular Application Must Contact The Procurement Contracting Officer.
3.15.2 If The Contractors Qualification Data Has Previously Been Approved By The Navy For Other Contracts, A Copy Of The Original Approval Letter May Be Submitted To Expedite The Approval Process. The Approval Letter Must Reference The Applicable Welding
procedure And Qualification Data Report Identification/number And Revision. Prior Approval Does Not Guarantee Acceptance For This Or Any Future Contracts. As Far As Practical, All Procedures For The Contract Must Be Submitted At The Same Time. Welding
procedures And Qualification Data Must Be Submitted In A Commercially Available Electronic Format Such As Adobe Acrobat Pdf. The Contractor Must State The Applicability Of Each Weld Procedure And Qualification Data Submitted, Citing The Drawing Number And
pieces To Be Welded. (i.e. "wp-123 And Qd-123 Are Submitted For The Weld Joint Between Pieces 1 And 2 On Drawing Abc." Wp-456 And Qd-456 Are Submitted For The Hardfacing Of Piece 3 On Drawing Xyz.") Authority For The Repair Of Special Repairs In Castings And
authority For The Repair Of Wrought Or Forged Material Must Be Obtained From The Procurement Contracting Officer. This Request Must Describe The Defect; Including Size, Depth, Location, And A Description Of The Proposed Repair. This Request For Navsup-wss
contracts Must Be Submitted Via The Electronic Contractor Data Submission (ecds) Application.
3.15.3 Any New Procedure Qualification Performed To S9047-aq-gib-010/248 Under This Contract Will Require The Vendor To Provide A Minimum 48 Hour Notification To Dcma With An Offer To Observe The Welding Of The Test Assemblies. The 48 Hour Time Limit May Be
modified Upon Mutual Agreement Between The Vendor And Dcma.
3.15.4 Preparation And Retention Of Weld Records Is Required, As Specified By Paragraph 4.1.3 Of S9074-ar-gib-010a/278 Or As Specified In Applicable Commercial Welding Specifications.
3.15.5 When Production Welds Or Repair Welds Are Performed By A Subcontractor, The Requirement For Submission Of All Certification Documentation Required Herein Must Be Passed Down To The Subcontractor.
4. Quality Assurance
4.1 Notes To Dcma Qar And The Contractor -
4.1.1 Dcma Qar And The Contractor For Proprietary Designs - Departures From Contractor Imposed Requirements, Not Specifically Covered By The Contract, Must Be Judged Individually On The Basis Of The Effect, If Any, On Contractual Requirements. When There Is A
disagreement Between The Contractor And The Government Representative As To The Effect On Contractual Requirements, The Departure Must Be Considered A Nonconformance And Be Submitted To The Pco For Disposition.
4.1.2 Dcma Qar And The Contractor For Proprietary Designs - All Records Of Departures From Contractor Imposed Requirements Must Be Maintained And Available For Review At The Contractor's Facility. A Copy Must Be Given To The Local Government Representative. A
record Of These Departures, Traceable To The Applicablepart Number And Contract Number Must Be Submitted To The Pco.
4.1.3 Dcma Qar And The Contractor For Proprietary Designs - For Proprietary Designs, The Contractor's Part Numbers Are Acceptable For Reference Only. The Delivered Material Must Conform To All Drawings, Specifications, And Other Contractual Requirements.
4.1.4 Dcma Qar - It Is The Responsibility Of Dcma Qar To Review Non-destructive Testing (ndt) Procedures For Navsup Contracts/purchase Orders.
4.1.5 Dcma Qar And The Contractor - The Ecds (electronic Contractor Data Submission) System Is Available For Certain Data Submissions And To Submit Questions And Clarifications, And Waiver Requests On Contracts And Solicitations. Ecds Can Be Found At:
https://register.nslc.navy.mil/
5. Packaging
5.1 Preservation, Packaging, Packing And Marking - Preservation, Packaging, Packing And Marking Must Be In Accordance With The Contract/purchase Order Schedule And As Specified Below.
mil-std 2073 Packaging Applies As Found Elsewhere In The Schedule
6. Notes
6.1 In Accordance With Opnavinst 5510.1 All Documents And Drawings Provided By The U.s. Navy To Perspective Contractors Must Include A "distribution Statement" To Inform The Contractor Of The Limits Of Distribution, And The Safeguarding Of The Information
contained On Those Documents And Drawings.
6.1.1 There Are 7 (seven) Separate Distribution Statement Codes Used For Non-classified Documents And Drawings. The Definition For Each Is As Follows:
a... Approved For Public Release; Distribution Is Unlimited.
b... Distribution Authorized To Us Governments Agencies Only.
c... Distribution Authorized To Us Government Agencies And Their Contractors.
d... Distribution Authorized To Dod And Dod Contractors Only.
e... Distribution Authorized To Dod Components Only.
f... Further Distribution Only As Directed By Commander, Naval Sea Systems Command, Code 09t.
x... Distribution Is Authorized To Us Government Agencies And Private Individuals Or Enterprises Eligible To Obtain Export Controlled Technical Data In Accordance With Opnavinst 5510.161.
6.2 Ordering Information For Document References - The Department Of Defense Single Stock Point (dodssp), Website Http://www.dsp.dla.mil/, Provides Product Information For The Department Of Defense Index Of Specifications And Standards (dodiss)
(i.e.military/federal Specifications And Standards), Data Item Descriptions (dids), And Other Dodssp Products. Most Specifications Can Obtained Directly From Http://quicksearch.dla.mil/
a. Availability Of Cancelled Documents - The Dodssp Offers Cancelled Documentsthat Are Required By Private Industry In Fulfillment Of Contractual Obligationsin Paper Format. Documents Can Be Requested By Phoning The Subscription Services Desk.
b. Commercial Specifications, Standards, And Descriptions - These Specifications, Standards And Descriptions Are Not Available From Government Sources. Theymay Be Obtained From The Publishers Of The Applicable Societies.
c. Ordnance Standards (os), Weapons Specifications (ws), And Navord Ostd 600 Pages - These Type Publications May Be Obtained By Submitting A Request To:
commander, Indian Head Division, Naval Surface Warfare Center
code 8410p, 101 Strauss Avenue
indian Head, Md 20640-5035
d. On Post-award Actions, Requests For "official Use Only" And "noforn" (not Releasable To Foreign Nationals) Documents Must Identify The Government Contractnumber, And Must Be Submitted Via The Cognizant Defense Contract Management Command (dcmc) For
certification Of Need For The Document. On Pre-award Actions Such Requests Must Be Submitted To The Pco For Certification Of Need For The Document.
e. Noforn Military Specifications And Standards (including Amendments, Change Notices And Supplements, But Not Interim Changes) To Be Ordered From:
contracting Officer
navsup-wss
code 87321
5450 Carlisle Pike
p.o. Box 2020
mechanicsburg, Pa. 17055-0788
f. Nuclear Reactor Publications Assigned Navsea Documents And Identification Numbers (i.e. Navsea Welding Standard, Navsea 250-1500-1) Are To Be Ordered Enue:
commanding Officer
navsup-wss
code 009
5450 Carlisle Pike
p.o. Box 2020
mechanicsburg, Pa. 17055-0788
g. Technical Manuals Assigned Navsea Identification Numbers (i.e. Navsea Welding And Brazing Procedure, Navsea S9074-aq-gib-010/248) Are To Be Ordered From:
commanding Officer
navsup-wss
code 1 Support Branch
700 Robbins Avenue
philadelphia, Pa. 19111-5094
h. Interim Changes And Classified Specifications Must Be Obtained By Submitting A Request On Dd Form 1425 To Navsup-wss.
6.3 Several Definitions Of Terms That Apply To Csi Items Are Listed Below. All Terms May Not Apply To Every Item.
6.3.1 The Ecds (electronic Contractor Data Submission) System Is At: Https://register.nslc.navy.mil/ This Application Will Require Advance Registration Using A Pki Digital Certificate On A Cac. A Vendor User Guide Is Available As Csd001 In The Csd
(contract Support Document) Library Within Ecds.
6.3.2 Critical Safety Item (csi) - Any Ship Part, Assembly, Or Support Equipment Containing A Critical Characteristic Whose Failure, Malfunction, Or Absence Of Which Could Cause A Catastrophic Or Critical Failure Resulting In Loss Of, Or Serious Damage To The
ship, Or Unacceptable Risk Of Personal Injury Or Loss Of Life.
6.3.3 Critical Process - As Determined By The Twh, Any Process, Operation Or Action Performed On A Ship Csi That Serves To Establish A Critical Characteristic (such As Welding, Soldering, Machining, Polishing, Cleaning, Or Assembling) Or Confirm That A
critical Characteristic Is Within Drawing Or Specification Compliance (such As, Testing, Measurement, Or Non-destructive Evaluation).
6.3.4 First Article - Pre-production Models, Initial Product Samples, Test Samples Produced To Ensure A Manufacturer's Capability To Meet Full Specification Requirements.
6.3.5 First Article Test (fat) - Contractually Required Testing And Inspection Of A Supplier's Pre-production, Production, Or "production Representative" Specimens To Evaluate A Manufacturer's Ability To Produce Conforming Product Prior To The Government's
commitment To Receive Subsequent Production Items. First Article Testing Is Product Specific And Does Not Assess Manufacturing Process Controls Nor Does It Assure The Effectiveness Of The Manufacturer's Quality Program.
6.3.6 Objective Quality Evidence (oqe) - The Quantitative And Qualitative Data Of All Mechanical, Chemical, And Performance Tests Performed (as Required By The Applicable Specification, Drawing, Or Purchase Document) To Prove That He Material Supplied
conforms To The Specified Requirements.
6.3.7 Surface Discontinuity - Any Surface Irregularity, Marking, Or Localized Change In Physical Character Of The Surface, Other Than Dimensional, That Exists Infrequently At One Or Several Places. (examples: Burrs, Dents, Nicks, Scratches, Gouges, Pits,
center-punches, Scribes, And Tool Marks). Surface Discontinuities Less Than 0.005-inch In Depth Are Acceptable Provided They Do Not Violate Any Other Design Requirements Specified In This Contract/purchase Order.
6.3.8 Traceability Code - A Code Or Number Providing Traceability To The Actual Chemical And Mechanical Properties Of The Specified Heat, Batch, Or Form From Which The Material Originated.
6.3.9 Verification - An Examination Performed To Determine Compliance With A Specific Requirement.
6.3.10 A Nonconformance Is Defined As Affecting Or Violating The Following:
- The Requirements Of This Contract/purchase Order.
- Contractually Invoked Drawings (i.e. Envelope Dimensions, Interface Dimensions With Mating Parts/equipment, Center Of Gravity, Weights, Piece Part Identification, Material, Etc.).
- Contractually Invoked Federal, Military, Or Commercial Specifications And/or Standards.
- Form, Fit, Function, Performance To Contract Requirements, Reliability, Maintainability, Interchangeability, Safety Of Personnel Or Equipment, Or Additional Cost To The Government.
6.3.11 Waiver - A Written Authorization To Accept An Item, Which During Manufacture, Or After Having Been Submitted For Government Inspection Or Acceptance, Is Found To Depart From Specified Requirements, But Nevertheless Is Considered Suitable For Use As Is
or After Repair By An Approved Method.
6.3.12 Deviation - A Specific Written Authorization (granted Prior To The Manufacture Of An Item) To Depart From A Particular Requirement(s) Of An Item's Current Approved Configuration Documentation For A Specific Number Of Units Or A Specified Period Of
time, And To Accept An Item Which Is Found To Depart From Specified Requirements, But Nevertheless Is Considered Suitable For Use "as Is" Or After Repair By An Approved Method.
6.3.13 Critical Waiver/deviation - This Waiver/deviation Consists Of A Departure Involving Safety.
6.3.14 Major Waiver/deviation - This Waiver/deviation Consists Of A Departure Involving:
- Performance
- Interchangeability, Reliability, Survivability, Maintainability,
Or Durability Of The Item Or Its Repair Parts
- Health Or Safety
- Effective Use Or Operation
- Weight, Stability, Or Structural Integrity
- System Design Parameters As Schematics, Flows, Pressures Or Temperatures
- Compartment Arrangements Or Assigned Function
6.3.15 Minor Waiver/deviation - This Waiver/deviation Consists Of A Departure Which Does Not Involve Any Of The Factors Listed As Critical Or Major.
6.3.16 Engineering Change (ec) - A Change To The Current Approved Configuration Documentation Of A Configuration Item At Any Point In The Life Cycle Of The Item.
6.3.17 Engineering Change Proposal (ecp) - A Proposed Engineering Change And The Documentation By Which The Change Is Described, Justified, And Submitted To The Government For Approval Or Disapproval.
date Of First Submission=asreq
paragraph 10.4 Of Di-qcic-81110 Does Not Apply.
date Of First Submission=asreq
block 4 - Paragraphs 10.2.1, 10.2.2, 10.2.3, 10.3, And 10.4 Of Di-misc-80678 Do Not Apply.
block 12 - Certification Data Must Be Submitted To Portsmouth Naval Shipyard For Review And Acceptance Prior To Each Shipment Of Material. Certification Documentation Must Be Submitted Via Wawf (wide Area Work Flow).
enter In Wawf As Follows:
"ship To" N50286
"inspect By" N39040
"accept By" N39040
and Email Notification Field: Port_ptnh_wawf_notification@navy.mil
no Material Is To Be Shipped Prior To The Receipt Of Acceptance.
date Of First Submission=asreq
block 4 - Paragraphs 10.2.2, 10.2.3, 10.2.4, And 10.3 Of Di-misc-80678 Do Not Apply.
block 12 - Certification Data Must Be Submitted To Portsmouth Naval Shipyard For Review And Acceptance Prior To Each Shipment Of Material. Certification Documentation Must Be Submitted Via Wawf (wide Area Work Flow).
enter In Wawf As Follows:
"ship To" N50286
"inspect By" N39040
"accept By" N39040
and Email Notification Field: Port_ptnh_wawf_notification@navy.mil
no Material Is To Be Shipped Prior To The Receipt Of Acceptance.
Closing Soon10 Jan 2025
Tender AmountRefer Documents
DEPT OF THE NAVY USA Tender
Others
Corrigendum : Closing Date Modified
United States
Description: Contact Information|4|n743.35|wwj|717-605-8399|tiana.hammaker@navy.mil|
item Unique Identification And Valuation (mar 2016)|19||||||||||||||||||||
higher-level Contract Quality Requirement (navicp Review Feb 1991)(feb 1999)|1|see Specifications Section C And Section E|
inspection Of Supplies--fixed-price (aug 1996)|2|||
inspection And Acceptance - Short Version (jun 2002)|8|x||x||||||
time Of Delivery (june 1997)|20|0001|5|180||||||||||||||||||
general Information-fob-destination|1|b|
wide Area Workflow Payment Instructions (dec 2018)|16|invoice And Receiving Report (combo)||tbd|n00104|tbd|tbd|n50286|tbd|||n/af||||||
navy Use Of Abilityone Support Contractor - Release Of Offeror Information (3-18))|1||
equal Opportunity (sep 2016)|2|||
warranty Of Supplies Of A Noncomplex Nature (june 2003)|6|one Year|365 Days After The Last Delivery Under This Contract |||||
warranty Of Data--basic (mar 2014)|2|||
buy American --free Trade Agreements--balance Of Payments Program - Basic(deviation 2020-o0019) (jul 2020))|3||||
notice Of Total Small Business Set-aside (oct 2020)(deviation 2020-o0008)|1||
alternate A, Annual Representations And Certifications (nov 2020)|13||||||||||||||
buy American-free Trade Agreements-balance Of Payments Program Certificate (deviation 2020-o0019) (jul 2020))|3||||
buy American-balance Of Payments Program Certificate-basic (nov 2014)|1||
annual Representations And Certifications (mar 2020)|13|335312|1250||||||||||||
notice Of Priority Rating For National Defense, Emergency Perpardeness, And Enrgy Progam Use (april 2008))|2||x|
evaluation Criteria And Basis For Award-|1||
solicitation Due Date Has Been Extended.
quantity Has Been Incrased To 6.
solicitation Due Date Is Hereby Extended.
1.dd1423 Data Item A001 (inspection And Test Plan) May Be Waived If Already On File At Navsup Wss Mechanicsburg.
2. All Contractual Documents (i.e. Contracts, Purchase Orders, Task Orders,delivery Orders, And Modifications) Related To The Instant Procurement Are Considered To Be "issued" By The Government When Copies Are Either Deposited In The Mail, Transmitted By
facsimile, Or Sent By Other Electronic Commerce Methods, Such As Email. The Government's Acceptance Of The Contractor's Proposal Constitutes Bilateral Agreement To "issue" Contractual Documents As Detailed Here In.
3.the Following Proposed Delivery Schedule Applies:
submission Of All Certification Data Cdrls 20 Days Prior To Delivery.
pnsy Review/acceptance Of Certification Cdrls 6 Working Days After Receipt
final Delivery Of Material (180 Days)
\
1. Scope
1.1 The Material Covered In This Contract/purchase Order Will Be Used In A Crucial Shipboard System. The Use Of Incorrect Or Defective Material Would Create A High Probability Of Failure Resulting In Serious Personnel Injury, Loss Of Life, Loss Of Vital
shipboard Systems, Or Loss Of The Ship Itself. Therefore, The Material Has Been Designated As Special Emphasis Material (level I, Scope Of Certification, Or Quality Assured) And Special Control Procedures Are Invoked To Ensure Receipt Of Correct Material.
1.1.1 Dssp Scope Of Certification Material - Material Control Division ;(b); Applies To This Material.
1.1.2 This ;motor Controller Ay; Contains Non-metallic Materials Which Must Satisfy The Toxicity And Flammability Requirements Of Navsea Ss800-ag-man-010/p-9290. Use Of Any Material Other Than That Specified Requires Special Engineering Approval And May
require Testing.
2. Applicable Documents
2.1 Order Of Precedence - In The Event Of A Conflict Between The Text Of This Contract/purchase Order And The References And/or Drawings Cited Herein, The Text Of This Contract/purchase Order Must Take Precedence. Nothing In This Contract/purchase Order,
however, Must Supersede Applicable Laws And Regulations Unless A Specific Exemption Has Been Obtained.
2.2 Applicable Documents - The Document(s) Listed Below Form A Part Of This Contract/purchase Order Including Modifications Or Exclusions.
2.3 Specification Revisions - The Specification Revisions Listed Under "docu Ments References" Below Are The Preferred Revision. Older And/or Newer R Evisions Are Acceptable When Listed Within Contract Support Library Reference Number Csd155 In Ecds (electric
contractor Data Submission) At: Ht Tps://register.nslc.navy.mil/. This Is To Allow Contractors To Use Certain Acceptable Older Specification Revisions To Purge Their Existing Stock Of Material Certified To Those Older Revisions Or To Use Newer Specification
revisions When Material Is Certified To Newly Released Revisions,without Requiring The Submittal Of Waiver/deviation Requests For Each Specification Revision On Every Contract. Revisions Of Specifications Reflecting Editorial And/or Re-approval (e.g. E2009,
r2014, Etc.) Are Considered Inconsequential, But Are Acceptable When Their Revisions Are Listedwithin Csd155 Or Elsewhere Within This Contract.
2.3.1 The Documents And Drawings Listed Below Under Drawing No. Are Not Provided With This Contract/purchase Order.
drawing No Cage Rev Distr Cd
;50271205 95310 E B;
2.3.2 "document References" Listed Below Must Be Obtained By The Contractor. Ordering Information Is Included As An Attachment To This Contract/purchase Order.
drawing Data=8500400 |53711| B| |d|0001 | |49998|1165538
drawing Data=8500409 |53711| C| |d|0001 | |49998|4778725
document Ref Data=ansi/asq Z1.4 | | | |080101|a| | |
document Ref Data=mil-std-792 | | |f |060519|a| | |
document Ref Data=iso_9001 | | | |081115|a| | |
document Ref Data=iso10012 | | | |030415|a| | |
document Ref Data=iso/iec 17025 | | | |050515|a| | |
document Ref Data=mil-i-45208 | | |a |810724|a|1 | |
document Ref Data=mil-std-45662 | | |a |880801|a| | |
document Ref Data=ansi/ncsl Z540.3 | | | |130326|a| | |
document Ref Data=ss800-ag-man-010/p-9290 | | | |200424|a| |04|
3. Requirements
3.1 ;the Motor Controller Ay Must Be Made In Accordance With Navsea Drawing 8500409 Item 41-5 Ac Winch Controller, Except As Amplified Or Modified Herein.;
3.2 Testing Certification - Certifications Are Required For The Following Tests On The Items Listed Below. Additional Testing On Other Piece Parts (if Any) Per Applicable Drawings Is Still Required, But Certifications Are Only Required As Listed Below.
3.3 ;ac Winch Controller In Accordance With Crane Midwest Dwg 50271205 Requires Implodable Volume Testing.;
3.4 Testing For All Critical Implodable Volumes Must Include Submergence Pressure Test To ;134 Psig; For 10 Cycles:
- Ten (10) Minutes At Test Pressure For Cycles 1-9
- One (1) Hour At Test Pressure For Cycle 10
the Test Must Be Conducted In 35 Degrees Fahrenheit Seawater If Practical. Leakage Or Visible Signs Of External Damage Must Be Cause For Test Failure. Pressure And Temperature Testing Equipment Used To Perform This Test Must Be Calibrated. Pressure Gauges Used
for This Testing Must Conform To The Following:
3.4.1 Selecting Master Hydrostatic Test Gages. When Selecting A Hydrostatic Test Gage, The Test Gage Range Should Be Greater Than The Test Pressure But Should Not Be More Than Twice That Of The Maximum Test Pressure Except For Test Pressures Below 60 Psi As
indicated On The "master Gage Selection For Hydro". See Reference Number Csd012 Of The Contract Support Library Page Of The Electronic Contractor Data Submission (ecds) System At Https://register.nslc.navy.mil/
3.4.2 Master Hydrostatic Test Gages And Backup Gages Must Have An Accuracy Of At Least +1.0 Percent Of Gage Span. In Addition, Master Hydrostatic Test Gages Must Have Graduations Equal To Or Smaller Than Those Shown In Table 504-6-1. Backup Gages May Be
installed With Dial Sizes Of 4 1/2 Inches Or Larger.
3.5 The Pressure Tolerance Must Be As Specified In The Assembly Drawing, Detail Drawing, Design Specification Or Elsewhere In This Contract. Where Pressure Tolerances Are Not Provided By Drawings, Specifications Or Specified Elsewhere In This Contract, The
following Must Be Used:
For Pressure Tests Below 100 Psig, The Pressure Tolerance Must Be +1 Psig/-0psig.
For Pressure Tests At Or Above 100 Psig Up To And Including 2500 Psig, The Pressure Tolerance Must Be +2% / -0 Psig Rounded Off To The Nearest Multiple Of Thesmallest Graduation On An Analog Test Pressure Gauge, Not To Exceed 50 Psig.
30 Minutes / - 0 Minutes. Above 2500 Psig, The Pressure Tolerance Must Be +2%/-0 Psig, Rounded Off To The Nearest Multiple Of The Smallest Graduation On An Analog Test Pressure Gauge, Not To Exceed 200 Psig.
The Pressure Test Time Tolerance Must Be As Specified In The Assembly Drawing, Detail Drawing, Design Specification Or Elsewhere In This Contract. Where Pressure Test Time Tolerances Are Not Provided By Drawings, Specifications Or Specified Elsewhere In
this Contract, The Following Must Be Used:
For A Test Duration Up To And Including 1 Hour, The Tolerance Must Be +5 Minutes / - 0 Minutes.
For A Test Duration Of More Than 1 Hour Up To And Including 24 Hours, The Tolerance Must Be +30 Minutes / - 0 Minutes.
For A Test Duration Of More Than 24 Hours, The Tolerance Must Be + 60 Minutes/- 0 Minutes.
3.5.1 A Copy Of The Final Waiver/deviation (both Approved And Disapproved) Must Be Forwarded With The Applicable Asset(s).
3.6 Mercury Free - Mercury And Mercury Containing Compounds Must Not Be Intentionally Added Or Come In Direct Contact With Hardware Or Supplies Furnished Under This Contract. Mercury Contamination Of The Material Will Be Cause For Rejection.
3.7 Configuration Control - The Contractor Must Maintain The Total Equipment Baseline Configuration. For Items Of Proprietary Design, Contractor Drawings Showing The Latest Assembly Configuration Must Be Provided To The Government In Electronic (c4) Format.
definitions Are Provided Elsewhere In The Contract/purchase Order.
3.7.1 Waivers/deviations - All Waivers And Deviations, Regardless Of Significance Or Classification Require Review And Approval By The Contracting Officer. Waivers And Deviations Must Be Designated As Critical, Major, Or Minor. The Contractor Must Provide A
copy Of This Request To The Qar. Requests Must Include The Information Listed Below.
A. A Complete Description Of The Contract Requirement Affected
And The Nature Of The Waiver/deviation (non-conformance),
Including A Classification Of Critical, Major, Or Minor.
B. Number Of Units (and Serial/lot Numbers) To Be Delivered In This
Configuration.
C. Any Impacts To Logistics Support Elements (such As Software,
Manuals, Spares, Tools, And Similar) Being Utilized By Government
Personnel Or Impacts To The Operational Use Of The Product.
D. Information About Remedial Action Being Taken To Prevent Reoccurrence
Of The Non-conformance.
3.7.2 All Requests For Waivers/deviations On Navsup-wss Contracts Must Be Submitted Using The Ecds (electronic Contractor Data Submission) System At Https://register.nslc.navy.mil/
3.7.3 Ecps - The Government Will Maintain Configuration Control And Change Authority For All Modifications Or Changes Affecting Form, Fit, Function, Or Interface Parameters Of The Equipment And Its Sub-assemblies. The Contractor Must Submit An Engineering
change Proposal (ecp) For Any Class I Or Ii Changes That Impact The Equipment Covered By This Contract. Ecps Must Be Prepared In Contractor Format, And Must Include The Following Information:
A. The Change Priority, Change Classification (class I Or Class Ii),
And Change Justification.
B. A Complete Description Of The Change To Be Made And The Need For
That Change.
C. A Complete Listing Of Other Configuration Items Impacted By The
Proposed Change And A Description Of The Impact On Those Cis.
D. Proposed Changes To Documents Controlled By The Government.
E. Proposed Serial/lot Number Effectivities Of Units To Be
Produced In, Or Retrofitted To, The Proposed Configuration.
F. Recommendations About The Way A Retrofit Should Be Accomplished.
G. Impacts To Any Logistics Support Elements (such As Software,
Manuals, Spares, Tools, And Similar) Being Utilized By Government
Personnel In Support Of The Product.
H. Impacts To The Operational Use Of The Product.
I. Complete Estimated Life-cycle Cost Impact Of The Proposed Change.
J. Milestones Relating To The Processing And Implementation Of The
Engineering Change.
3.8 Certificate Of Compliance - (special Emphasis Material) The Contractor Must Prepare And Submit A Certificate Of Compliance Certifying That The Items/components Furnished Under This Contract Comply With The Requirements Of The Procurement Document,
including Any/all Invoked Specifications And Drawings.
^ Quality Assurance Requirements ^
3.9 Quality System Requirements - The Contractor Furnishing Items Under This Contract/purchase Order Must Provide And Maintain A Quality System In Accordance With Iso-9001 As Amplified Or Modified Herein, With The Calibration System Requirements Of Iso-10012
or Ansi-z540.3 With Iso-17025. A Quality System In Accordance With Mil-i-45208, With The Calibration System Requirements Of Mil-std-45662, Is Acceptable As An Alternate.
3.9.1 The Contractor's Quality System And Products Supplied Under The System Are Subject To Evaluation, Verification Inspection, And Acceptance/nonacceptance By The Government Representative To Determine The System's Effectiveness In Meeting The Quality
requirements Established In The Contract/purchase Order.
3.9.2 The Contractor's Quality System Must Be Documented And Must Be Available For Review By The Contracting Officer Or His Representative Prior To Initiation Of Production And Throughout The Life Of The Contract. The Prime Contractor Must, Upon
notification, Make His Facilities Available For Audit By The Contracting Officer Or His Authorized Representative.
3.9.3 See Cdrl Di-qcic-81110 (inspection System Procedures) - All Suppliers Of Deep Submergence Systems Program (dssp) Material Are Required To Submit A Copy Of Their Current Documented Quality System Procedures To The Procurement Contracting Officer (pco)
prior To Award Of Any Contract/purchase Order. Suppliers That Have A Copy Of Their Current Quality System Procedures On File At Navicp-mech May Request The Pco Waive This Requirement.
3.9.4 This Contract Provides For The Performance Of Government Quality Assurance At Source. The Place Or Places Of Performance May Not Be Changed Without The Authorization Of The Procurement Contracting Officer. Upon Receipt Of This Order, Promptly
notify The Government Representative Who Normally Services Your Plant So That Appropriate Planning For Government Inspection Can Be Accomplished. If You Do Not Have An Assigned Government Representative, Notify The Nearest Defense Contract Management Agency
(dcma) Office. In The Event That A Local Government Representative Or Dcma Office Cannot Be Located, Our Purchasing Agent Should Be Notified Immediately.
3.9.5 Any Changes Made By The Contractor To A Qualified Quality System Will Require Concurrence By The Government Quality Assurance Representative Prior To Adoption.
3.10 Contractor Inspection Requirements - The Contractor Must Maintain Adequate Records Of All Inspections And Tests. The Records Must Indicate The Nature And Number Of Observations Made, The Number And Type Of Deficiencies Found, The Quantities Approved
and Rejected And The Nature Of Corrective Action Taken As Appropriate.
3.10.1 The Supplier's Gages, Measuring And Test Equipment Must Be Made Available For Use By The Government Representative When Required To Determine Conformance With Contract Requirements. When Conditions Warrant, The Supplier's Personnel Must Be Made
available For Operations Of Such Devices And For Verification Of Their Accuracy And Condition.
3.10.2 All Documents And Reference Data Applicable To This Contract Must Be Available For Review By The Government Representative. Copies Of Documents Required For Government Inspection Purposes Must Be Furnished In Accordance With The Instructions
provided By The Government Representative.
3.11 Subcontractor Inspection Requirements - The Government Has The Right To Inspect At Source, Any Supplies Or Services That Were Not Manufactured/performed Within The Contractor's Facility. Such Inspection Can Only Be Requested By Or Under Authorization Of
the Government Representative. Any Purchasing Documents To A Subcontractor Must Cite The Applicable Portions Of The Contractually Invoked Quality System (e.g. Calibration Requirements), Plus Any Product Requirements That Apply To The Supplies Being Purchased.
when The Government Elects To Perform Source Inspection At The Subcontractor's Facility, Applicable Purchase Documents Must Be Annotated With The Following Statement: "a Government Inspection Is Required Prior To Shipment From Your Plant. Upon Receipt Of
this Order, Promptly Notify The Government Representative Who Normally Services Your Plant So That Appropriate Planning For Government Inspection Can Be Accomplished. If You Do Not Have An Assigned Government Representative, Notify The Nearest Defense Contract
management Agency (dcma) Office. In The Event That A Local Government Representative Dcma Office Cannot Be Located, Our Purchasing Agent Should Be Notified Immediately."
3.12 Government Furnished Material And/or Equipment (gfm/gfe) - When Material Or Equipment Is Furnished By The Government, The Contractor Must Develop Documented Control Procedures That Require At Least The Following:
3.12.1 Visual Examination Upon Receipt To Detect Damage During Transit.
3.12.2 Inspection For Completeness And Proper Type.
3.12.3 Verification Of Material Quality Received.
3.12.4 Periodic Inspection And Precautions To Assure Adequate Storage Conditions And To Guard Against Damage From Handling And Deterioration During Storage.
3.12.5 Functional Testing, Either Prior To Or After Installation, Or Both, As Required By The Contract To Determine Satisfactory Operation.
3.12.6 Identification And Protection From Improper Use Or Disposition.
3.12.7 Reporting To The Government, Any Gfm Or Gfe Property Found Damaged, Malfunctioning, Or Otherwise Unsuitable For Use. In The Event Of Damage Or Malfunction During Or After Installation, The Supplier Must Determine And Record Probable Cause And
necessity For Withholding The Material From Use.
3.12.8 For Gfe Material, And As Required By The Terms Of The Bailment Agreement, The Supplier Must Establish Procedures For Adequate Storage, Maintenance, And Inspection Of Bailed Government Material. Records Of All Inspection And Maintenance Performed On
bailed Property Must Be Maintained.
3.12.9 Material Returned To The Contractor Must Be Handled As Gfm.
3.13 Traceability And Certification Requirements - To Assure That Correct Materials Are Installed In Dssp Systems, It Is Imperative That Traceability Be Maintained From The Material To All Required Objective Quality Evidence (oqe).
3.13.1 The Following Provides The Minimum Requirements For Maintaining Material Traceability And Supplements The Requirements Specified Elsewhere In The Contract/purchase Order.
3.14 Material Traceability - Traceability Markings Must Be Permanently Applied To The Material In Accordance With Mil-std-792 Or To A Tag Affixed To The Material, And Annotated On The Required Oqe. The Traceability Marking May Be Any Vendor Traceability
number/code Which Provides Complete Traceability To The Required Oqe. Traceability Marking/identification May Include Such Items As Nomenclature, Part Number, Technical Description, National Stock Number (nsn), Etc. Traceability Must Be Maintained Through All
process Operations Including Any Subcontracted Operations, To The Finished Component.
3.14.1 When Traceability Markings On The Material Would Be Removed By A Manufacturing Or Fabrication Process, The Marking Must Be Recorded Prior To Removal And Be Immediately Restored Upon Completion Of The Process. If This Cannot Be Done Or Is Impractical,
an Appropriate Material Control Procedure (such As A Bag And Tag, Tagging, And/or Tote Box Control) Must Be Employed.
the Material Control Procedure Must Provide A Method Of Positive Control To Preclude Commingling Of Material Or Loss Of Traceability. The Traceability Marking Must Be Reapplied Upon Completion Of The Final Manufacturing Process.
3.14.2 The Material Control Process Must Include Requirements For The Maintenance Of Traceability For Items Sent Out For Subcontracted Operations. If Such Operations Would Remove Traceability Markings On The Material, Purchase Or Work Orders Must Specify A
method And Marking Location For Remarking. The Contractor Must Also Ensure That Subcontractor Production Controls Are Adequate To Preclude Commingling Of Materials During Processing.
3.15 Final Inspection - The Following Inspections Must Be Performed Prior To Government Inspection And Acceptance.
3.15.1 Material Sampling - Material Must Be Inspected For Form, Fit, And Function. Lot Acceptance Must Be Based On Zero Defects And Lot Rejection Based On One Defect. The Sample Size Must Be In Accordance With The Sampling Plan(s) In The Applicable Military
specification Or Standard, Federal Specification Or Standard, Or Drawing To Which The Material Was Manufactured. In The Absence Of Such Sampling Plans, Sampling Inspection Must Be Per Ansi/asq-z1.4, General Inspection Level Ii (for Sample Size Selection Code),
table Iia (for Sample Size).
small Lot Sizes - For Lot Sizes Of Fifty Or Less, The Minimum Sample Size Must Be Eight Units. For Lot Sizes Of Eight Or Less, The Sample Size Must Be One Hundred Percent Of The Lot.
3.15.2 The Manufacturer May Elect To Use Statistical Process Control (spc) To Assure Product Quality In Lieu Of The Above Attribute Sampling Plan, Provided That The Spc Methodology/system Used Provides Acceptable Products To The Government. However, The
government Inspection Activity May Perform Their Acceptance Inspection Of The Material Using The Attribute Sampling Plan Outlined Above.
3.15.3 All Oqe Required By The Contract And All Data Concerning Material Traceability (oqe To Traceability Marking) Must Be 100% Inspected. The Certification Test Reports Must Also Be 100% Inspected For Completeness And Legibility.
3.16 Test Certification - When Test Certifications Are Required Elsewhere In The Contract, Certification Documents Must Be Positive And Unqualified. Disclaimers Such As "to The Best Of Our Knowledge" Or "we Believe The Information Contained Herein Is True"
are Not Acceptable.
3.16.1 If Material Is Received Without The Required Test Certification Papers Or With Incorrect/missing Data On The Certification Papers, The Material Will Be Rejected.
3.17 See Cdrl Di-misc-80678 (special Emphasis C Of C) - The Certificate Of Compliance Must Show Traceability To The Marking Applied On Each Individual Item, And Must Contain The Following Information:
1. Contractor's Name, Address, Phone Number And Date.
2. The Contract/purchase Order Number (i.e. N00104-11-p-fa12)
3. The National Stock Number (nsn). The 18 Character National Stock Number For Special Emphasis Material Includes The Two Digit Cog, The Four Digit Fsc, The 9digit Niin, And The Two Digit Smic (i.e. 1h 4820 012345678 D4)
4. Lubricants, Sealants, Anti-seize, And/or Thread Locking Compounds. ("n/a" When Not Applicable).
5. Cure Date ("n/a" When Not Applicable).
6. Manufacturer's Compound Number ("n/a" When Not Applicable).
7. When Weld Procedure Submittal Is Required By The Contract, A Statement That The Approval Date Of The Qualification Data Precedes Any Production Or Repair Welding Performed On This Contract. ("n/a" When Not Applicable).
8. A Statement For Any Hull, Mechanical And Electrical (hm&e) Testing Required That Include The Name Of The Test And That It Was Performed Satisfactorily. If No Hm&e Testing Is Required, The Statement Should Read "hull, Mechanical And Electrical (hm&e) Testing
n/a."
9. A Statement To The Effect That All Items Furnished On This Contract Are In Full Compliance With The Specifications And Requirements.
10. Contractor's Or Authorized Personnel's Signature.
3.17.1 For Connectors, Cables, And Junction Boxes Procured To Eb Specs S-5343934-1, S-5343934-2, Or S-5343934-3, The Certificate Of Compliance Must Also Include The Information Below:
11. A Notation That 32 Root Mean Square (rms) Finishes Are In Accordance With The Specifications And Are Free Of Imperfections.
12. Direct Reading Of O-ring Surface Diameters With Specified Standard.
3.18 See Cdrl Di-misc-80678 (soc Critical Volume Testing) - The Critical Volume Test Record (implodable/explodable), As A Minimum, Must Include The Following Information:
A. Name(s), Model Number(s), And Serial Number(s) Of Component(s) Tested.
B. Date Of Test.
C. Serial Number(s) Of Gage(s) Used For The Test.
D. Last Calibration Date Of The Pressure Gage(s) Used In The Test.
E. Next Calibration Due Date Of The Pressure Gage(s) Used In The Test.
F. Test Medium Temperature Required And Actual Test Medium Temperature Used.
G. Pressure Range And Accuracy Of Gage(s) Used.
H. Test Pressure For Each Pressure Cycle.
I. Required And Actual Duration Of Each Pressure Cycle.
J. Results Of The Test (i.e., Sat Or Unsat) Per The Above Criteria.
K. Printed Name(s) And Signature(s), Or Identification Number(s) And
Signature(s) Of Test Conductor(s)/inspector(s), And The Date Of Each
Signature.
4. Quality Assurance
4.1 Notes To Dcma Qar And The Contractor -
4.1.1 Dcma Qar And The Contractor For Proprietary Designs - Departures From Contractor Imposed Requirements, Not Specifically Covered By The Contract, Must Be Judged Individually On The Basis Of The Effect, If Any, On Contractual Requirements. When There Is A
disagreement Between The Contractor And The Government Representative As To The Effect On Contractual Requirements, The Departure Must Be Considered A Nonconformance And Be Submitted To The Pco For Disposition.
4.1.2 Dcma Qar And The Contractor For Proprietary Designs - All Records Of Departures From Contractor Imposed Requirements Must Be Maintained And Available For Review At The Contractor's Facility. A Copy Must Be Given To The Local Government Representative. A
record Of These Departures, Traceable To The Applicablepart Number And Contract Number Must Be Submitted To The Pco.
4.1.3 Dcma Qar And The Contractor For Proprietary Designs - For Proprietary Designs, The Contractor's Part Numbers Are Acceptable For Reference Only. The Delivered Material Must Conform To All Drawings, Specifications, And Other Contractual Requirements.
4.1.4 Dcma Qar - It Is The Responsibility Of Dcma Qar To Review Non-destructive Testing (ndt) Procedures For Navsup Contracts/purchase Orders.
4.1.5 Dcma Qar And The Contractor - The Ecds (electronic Contractor Data Submission) System Is Available For Certain Data Submissions And To Submit Questions And Clarifications, And Waiver Requests On Contracts And Solicitations. Ecds Can Be Found At:
https://register.nslc.navy.mil/
5. Packaging
5.1 Preservation, Packaging, Packing And Marking - Preservation, Packaging, Packing And Marking Must Be In Accordance With The Contract/purchase Order Schedule And As Specified Below.
mil-std 2073 Packaging Applies As Found Elsewhere In The Schedule
6. Notes
6.1 Several Definitions Of Terms That Apply To Csi Items Are Listed Below. All Terms May Not Apply To Every Item.
6.1.1 The Ecds (electronic Contractor Data Submission) System Is At: Https://register.nslc.navy.mil/ This Application Will Require Advance Registration Using A Pki Digital Certificate On A Cac. A Vendor User Guide Is Available As Csd001 In The Csd
(contract Support Document) Library Within Ecds.
6.1.2 Critical Safety Item (csi) - Any Ship Part, Assembly, Or Support Equipment Containing A Critical Characteristic Whose Failure, Malfunction, Or Absence Of Which Could Cause A Catastrophic Or Critical Failure Resulting In Loss Of, Or Serious Damage To The
ship, Or Unacceptable Risk Of Personal Injury Or Loss Of Life.
6.1.3 Critical Process - As Determined By The Twh, Any Process, Operation Or Action Performed On A Ship Csi That Serves To Establish A Critical Characteristic (such As Welding, Soldering, Machining, Polishing, Cleaning, Or Assembling) Or Confirm That A
critical Characteristic Is Within Drawing Or Specification Compliance (such As, Testing, Measurement, Or Non-destructive Evaluation).
6.1.4 First Article - Pre-production Models, Initial Product Samples, Test Samples Produced To Ensure A Manufacturer's Capability To Meet Full Specification Requirements.
6.1.5 First Article Test (fat) - Contractually Required Testing And Inspection Of A Supplier's Pre-production, Production, Or "production Representative" Specimens To Evaluate A Manufacturer's Ability To Produce Conforming Product Prior To The Government's
commitment To Receive Subsequent Production Items. First Article Testing Is Product Specific And Does Not Assess Manufacturing Process Controls Nor Does It Assure The Effectiveness Of The Manufacturer's Quality Program.
6.1.6 Government Source Inspection (gsi) - Gsi Is Independent Oversight Performed By A Government Representative Usually A Dcma Quality Assurance Representative (qar)) To Assure That Those Unique Product Quality And System Elements, Identified By The
contracting Agency As Important, Are Observed And Evaluated.
6.1.7 Quality Assurance Letter Of Instruction (qali) - A Qali Is A Formal Document Initiated By A Contracting Activity That Provides Essential Requirements And Instructions For Contracted Materials To Be Independently Verified And Accepted By A Government
representative Prior To Shipment.
6.1.8 Objective Quality Evidence (oqe) - The Quantitative And Qualitative Data Of All Mechanical, Chemical, And Performance Tests Performed (as Required By The Applicable Specification, Drawing, Or Purchase Document) To Prove That The Material Supplied
conforms To The Specified Requirements.
6.1.9 Surface Discontinuity - Any Surface Irregularity, Marking, Or Localized Change In Physical Character Of The Surface, Other Than Dimensional, That Exists Infrequently At One Or Several Places. (examples: Burrs, Dents, Nicks, Scratches, Gouges, Pits,
center-punches, Scribes, And Tool Marks) Surface Discontinuities Less Than 0.005-inch In Depth Are Acceptable Provided They Do Not Violate Any Other Design Requirements Specified In This Contract/purchase Order.
6.1.10 Traceability Code - A Code Or Number Providing Traceability To The Actual Chemical And Mechanical Properties Of The Specified Heat, Batch, Or Form From Which The Material Originated.
6.1.11 Verification - An Examination Performed To Determine Compliance With A Specific Requirement.
6.1.12 Nonconformance - A Nonconformance Is Defined As Affecting Or Violating The Following:
- The Requirements Of This Contract/purchase Order.
- Contractually Invoked Drawings (i.e. Envelope Dimensions, Interface Dimensions With Mating Parts/equipment, Center Of Gravity, Weights, Piece Part Identification, Material, Etc.).
- Contractually Invoked Federal, Military, Or Commercial Specifications And/or Standards.
- Form, Fit, Function, Performance To Contract Requirements, Reliability, Maintainability, Interchangeability, Safety Of Personnel Or Equipment, Or Additional Cost To The Government.
6.1.13 Waiver - A Written Authorization To Accept An Item, Which During Manufacture, Or After Having Been Submitted For Government Inspection Or Acceptance, Is Found To Depart From Specified Requirements, But Nevertheless Is Considered Suitable For Use As Is
or After Repair By An Approved Method.
6.1.14 Deviation - A Specific Written Authorization (granted Prior To The Manufacture Of An Item) To Depart From A Particular Requirement(s) Of An Item's Current Approved Configuration Documentation For A Specific Number Of Units Or A Specified Period Of
time, And To Accept An Item Which Is Found To Depart From Specified Requirements, But Nevertheless Is Considered Suitable For Use "as Is" Or After Repair By An Approved Method.
6.1.15 Critical Waiver/deviation - This Waiver/deviation Consists Of A Departure Involving Safety.
6.1.16 Major Waiver/deviation - This Waiver/deviation Consists Of A Departure Involving:
- Performance
- Interchangeability, Reliability, Survivability, Maintainability, Or Durability Of The Item Or Its Repair Parts
- Health Or Safety
- Effective Use Or Operation
- Weight, Stability, Or Structural Integrity
- System Design Parameters As Schematics, Flows, Pressures Or Temperatures
- Compartment Arrangements Or Assigned Function
6.1.17 Minor Waiver/deviation - This Waiver/deviation Consists Of A Departure Which Does Not Involve Any Of The Factors Listed As Critical Or Major.
6.1.18 Engineering Change (ec) - A Change To The Current Approved Configuration Documentation Of A Configuration Item At Any Point In The Life Cycle Of The Item.
6.1.19 Engineering Change Proposal (ecp) - A Proposed Engineering Change And The Documentation By Which The Change Is Described, Justified, And Submitted To The Government For Approval Or Disapproval.
6.1.20 Class I Ecp - A Class I Ecp Is Approved By The Government's Configuration Control Board And Authorized With A Contract Modification.
6.1.21 Class Ii Ecp - A Class Ii Change Is Typically Reviewed For Concurrence In Classification By The Local Government Representative, Unless Otherwise Specified Elsewhere In The Contract/purchase Order.
6.2 In Accordance With Opnavinst 5510.1 All Documents And Drawings Provided By The U.s. Navy To Perspective Contractors Must Include A "distribution Statement" To Inform The Contractor Of The Limits Of Distribution, And The Safeguarding Of The Information
contained On Those Documents And Drawings.
6.2.1 There Are 7 (seven) Separate Distribution Statement Codes Used For Non-classified Documents And Drawings. The Definition For Each Is As Follows:
a... Approved For Public Release; Distribution Is Unlimited.
b... Distribution Authorized To Us Governments Agencies Only.
c... Distribution Authorized To Us Government Agencies And Their Contractors.
d... Distribution Authorized To Dod And Dod Contractors Only.
e... Distribution Authorized To Dod Components Only.
f... Further Distribution Only As Directed By Commander, Naval Sea Systems Command, Code 09t.
x... Distribution Is Authorized To Us Government Agencies And Private Individuals Or Enterprises Eligible To Obtain Export Controlled Technical Data In Accordance With Opnavinst 5510.161.
6.3 Ordering Information For Document References - The Department Of Defense Single Stock Point (dodssp), Website Http://www.dsp.dla.mil/, Provides Product Information For The Department Of Defense Index Of Specifications And Standards (dodiss)
(i.e.military/federal Specifications And Standards), Data Item Descriptions (dids), And Other Dodssp Products. Most Specifications Can Obtained Directly From Http://quicksearch.dla.mil/
a. Availability Of Cancelled Documents - The Dodssp Offers Cancelled Documentsthat Are Required By Private Industry In Fulfillment Of Contractual Obligationsin Paper Format. Documents Can Be Requested By Phoning The Subscription Services Desk.
b. Commercial Specifications, Standards, And Descriptions - These Specifications, Standards And Descriptions Are Not Available From Government Sources. Theymay Be Obtained From The Publishers Of The Applicable Societies.
c. Ordnance Standards (os), Weapons Specifications (ws), And Navord Ostd 600 Pages - These Type Publications May Be Obtained By Submitting A Request To:
commander, Indian Head Division, Naval Surface Warfare Center
code 8410p, 101 Strauss Avenue
indian Head, Md 20640-5035
d. On Post-award Actions, Requests For "official Use Only" And "noforn" (not Releasable To Foreign Nationals) Documents Must Identify The Government Contractnumber, And Must Be Submitted Via The Cognizant Defense Contract Management Command (dcmc) For
certification Of Need For The Document. On Pre-award Actions Such Requests Must Be Submitted To The Pco For Certification Of Need For The Document.
e. Noforn Military Specifications And Standards (including Amendments, Change Notices And Supplements, But Not Interim Changes) To Be Ordered From:
contracting Officer
navsup-wss
code 87321
5450 Carlisle Pike
p.o. Box 2020
mechanicsburg, Pa. 17055-0788
f. Nuclear Reactor Publications Assigned Navsea Documents And Identification Numbers (i.e. Navsea Welding Standard, Navsea 250-1500-1) Are To Be Ordered Enue:
commanding Officer
navsup-wss
code 009
5450 Carlisle Pike
p.o. Box 2020
mechanicsburg, Pa. 17055-0788
g. Technical Manuals Assigned Navsea Identification Numbers (i.e. Navsea Welding And Brazing Procedure, Navsea S9074-aq-gib-010/248) Are To Be Ordered From:
commanding Officer
navsup-wss
code 1 Support Branch
700 Robbins Avenue
philadelphia, Pa. 19111-5094
h. Interim Changes And Classified Specifications Must Be Obtained By Submitting A Request On Dd Form 1425 To Navsup-wss.
6.4 Recent Updates - A Short Description Of Recent Updates To The Technical Requirements Of This Item Are Listed Below, Along With An Implementation Date For Each Issue. The Notes Below Are Only A Generic Quick Reference And Are Provided For Convenience
only, Detailed Requirements Will Be Defined Elsewhere In The Technical Sections Of This Contract/purchase Order.
;- 10/20/2016 - Updated Ecds Url
- Feb 26 2009 - Clarified Testing And Certs Only Apply To Pieces Listed
- Oct 29 2010 - Added Sampling Std For Li In-process Testing
- Sep 30 2008 - Thread Inspection Requirements Were Clarified
- Dec 17 2011 - Began Using Ecds For Submissions
- Jan 05 2012 - Added Wawf To Forward Approved Waivers/deviations With Final Oqe
- Dec 17 2011 - Moved Quality Assurance Text Location For Readability
- Jan 19 2011 - Added Notification Of Dcma Upon Contract Award
- Dec 01 2011 - Moved "notes To Dcma Qar" To Qa Section
- Jan 5 2017 - Ecds/csd Info Was Added To Definitions In The Notes Section;
date Of First Submission=asreq
paragraph 10.4 Of Di-qcic-81110 Does Not Apply.
date Of First Submission=asreq
block 4 - Paragraphs 10.2.1, 10.2.2, 10.2.3, 10.3, And 10.4 Of Di-misc-80678 Do Not Apply.
block 12 - Certification Data Must Be Submitted To Portsmouth Naval Shipyard For Review And Acceptance Prior To Each Shipment Of Material. Certification Documentation Must Be Submitted Via Wawf (wide Area Work Flow).
enter In Wawf As Follows:
"ship To" N50286
"inspect By" N39040
"accept By" N39040
and Email Notification Field: Port_ptnh_wawf_notification@navy.mil
no Material Is To Be Shipped Prior To The Receipt Of Acceptance.
date Of First Submission=asreq
block 4 - Paragraphs 10.2.2, 10.2.3, 10.2.4, And 10.3 Of Di-misc-80678 Do Not Apply.
block 12 - Certification Data Must Be Submitted To Portsmouth Naval Shipyard For Review And Acceptance Prior To Each Shipment Of Material. Certification Documentation Must Be Submitted Via Wawf (wide Area Work Flow).
enter In Wawf As Follows:
"ship To" N50286
"inspect By" N39040
"accept By" N39040
and Email Notification Field: Port_ptnh_wawf_notification@navy.mil
no Material Is To Be Shipped Prior To The Receipt Of Acceptance.
Closing Date7 Feb 2025
Tender AmountRefer Documents
Pgnig Termika S A Tender
Others
Corrigendum : Closing Date Modified
Poland
Details: The subject of the proceedings is the purchase of 16 winter tires: 195/65 R15 91h - 16 pcs; In order to install them in vehicles operated in the Silesian Police Garrison, the Ordering Party requires the contractor to offer in this Procedure winter tires from a closed catalog of manufacturers including the following tire manufacturers: Falken, Firestone, Fulda, Hankook, Kleber, Toyo, Uniroyal, Bridgestone, Continental, Dunlop, Goodyear , Michelin, Nokian Pirelli, Vredestein, Yokohama, Dębica, Kormoran, Barum, laufenn The Contractor Indicates the Name of the Offered Tire Manufacturer in the Description of the Offered Item. Conditions: The order will be fulfilled on the basis of a one-time delivery resulting from the signed order. Delivery of the order must be completed within 3 days of signing the order. The Contractor undertakes to deliver the subject of the order at his own expense to the warehouse of So Katowice, Transport Department, Kwp W Katowice 40-068 Katowice Ul. Lompy 19; Delivery should be made from Monday to Friday between 8:00 a.m. and 2:00 p.m.; Payment type transfer; Payment term: Min. 30 Days Warranty: Manufacturer's warranty The delivered assortment must be manufactured as brand new, free from technical and legal defects, approved for trading and of the first quality. The tire's production date cannot be older than 12 months from the date of delivery. The Ordering Party reserves the right to withdraw from awarding the order without giving a reason, which may not constitute the basis for any claims of the invited contractor against the Ordering Party. Please submit all inquiries via the Purchasing Platform. In case of problems with submitting an offer, please contact the Eb2b Helpdesk - Contact in the footer of the website.
Closing Soon17 Jan 2025
Tender AmountRefer Documents
MPWIK W M ST WARSZAWIE S A Tender
Furnitures and Fixtures
Poland
Details: The Ordering Party Invites You to Submit an Offer for Servicing Gas Installations and Gas Boilers, Including Burners and Reduction Stations, Divided into Tasks. Task 1. Inspection and Maintenance of a Single-Pipe Reduction and Measurement Station for the “Pruszków” Plant. Task No. 2: Servicing of Gas Installation Lines for Air, Nitrogen, Helium, Argon, Acetylene for the Laboratory Division. Task 3: Inspection and Maintenance of the Reduction and Measurement Station for the “Dębe” Plant. Description of the Subject of the Order, Offer Form, Draft Purchase Order and General Terms and Conditions of the Order for Services are in the Attachments Tab. The Offer Should Be Submitted Through the Company’s Purchasing Platform, Exclusively from Your Profile Registered on the Purchasing Platform by Attaching the Offer Form in the Attachments Tab. It is considered that the person placing all documents, applications, notifications and offers on the Company's Purchasing Platform is authorized by the Contractor and acts on his behalf. All documents requiring signatures of persons representing the contractor must be submitted: - In electronic form - a scan (with visible signatures of persons representing the contractor) or - in electronic form with a qualified electronic signature. The documents must be of appropriate quality, minimum 150 dpi (enabling reading of the content contained in the document. The Ordering Party allows the submission of offers for individual tasks. The Ordering Party allows the possibility of awarding the order to the contractor who submits the most advantageous offer in the purchase mode on the basis of § 7 sec. 2 item 6) of Regulations R-pzp-02 Granting by the Municipal Water and Sewage Company in the Capital City of Warsaw Warsaw Public Procurement Law Not Covered by the Mandatory Application of the Public Procurement Law - Edition 01 (published on the website www.mpwik.com.pl.)
Closing Soon13 Jan 2025
Tender AmountNA
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Civil And Construction...+1Building Construction
United States
Details: ****amended To Say: Responses Due By 28 January 2025, See Revised 36c25725r0010******
presolicitation Notice Presolicitation Notice Request For Sf330 - Project 549a4-23-600, Design Project To Construct A New Central Plant To Replace The Original Building #11 Boiler Plant (1978) And Joined Chiller Plant (1987) Located At The Sam Rayburn Memorial Veterans Center (srmvc), Va North Texas Health Care System, 1201 E. 9th St., Bonham, Texas 75418.
this Is Not A Request For Proposal. This Is A Request For Standard Form (sf) 330 Architect-engineer Qualifications Packages Only. All Information Needed To Submit Sf 330 Documents Is Contained Herein. No Solicitation Package, Technical Information, Or Bidder/plan Holder List Will Be Issued. The Government Will Not Pay, Nor Reimburse, Any Costs Associated With Responding To This Request. The Government Is Under No Obligation To Award A Contract As A Result Of This Announcement.
1. General Information: The Veterans Health Administration (vha) Network Contract Office 17 (nco17) Is Seeking Sources And Intends To Award A Firm-fixed Price Design Contract For Architect-engineering (a-e) Services For Project 549a4-23-600, Design Project To Construct A New Central Plant To Replace The Original Building #11 Boiler Plant (1978) And Joined Chiller Plant (1987) Located At The Sam Rayburn Memorial Veterans Center (srmvc), Va North Texas Health Care System, 1201 E. 9th St., Bonham, Texas 75418. The A/e Shall Provide Investigative And Feasibility Design Services, Schematic Design Drawings, Design Development Drawings, Construction Documents, Final Bid Documents, Specifications, Calculations, Cost Estimates, Narratives, Bidding Support Services, Solicitation Support Services, And Construction Period Services For All Facets Of Work And Disciplines/trades To Facilitate The Construction Of The Central Plant At The Srmvc. The A-e Services Contract That Is Anticipated To Be Awarded Will Be Procured In Accordance With The Selection Of Architects And Engineers Statute [formerly Known As The Brooks Architect Engineer Act], Federal Acquisition Regulation Part 36.6 Architectural And Engineering Services, Va Acquisition Regulation 836.6, And Va Acquisition Manual M836.6 Architect-engineer Services. In Accordance With Far 36.209, Construction Contracts With Architect-engineer Firms, No Contract For The Construction Of A Project Shall Be Awarded To The Firm That Designed The Project Or Its Subsidiaries Or Affiliates, Except With The Approval Of The Head Of The Agency Or Authorized Representative.
2. Project Information This Project Is A 100% Set-aside For Service-disabled Veteran-owned Small Business (sdvosb) Concerns. The Naics Code For This Procurement Is 541310 Architect Services And The Annual Small Business Size Standard Is $12.5m. A Full Design Team Is Required To Complete This Project. The Projected Award Date For The Anticipated A-e Contract Is On Or Before Early June 2025.
3. Scope Of Design See Attached Statement Of Work
4. A-e Selection Process: Firms Submitting Sf330s In Response To This Announcement, Not Later Than The Closing Date And Time Specified Herein And In Accordance With Submission Requirements, Will Be Considered For Evaluation. Sf330s Will Be Evaluated In Accordance With The Selection Criteria Listed Below To Determine The Most Highly Qualified Firms For This Requirement. The Government Will Notify And Conduct Discussions With A Minimum Of Three Of The Most Highly Qualified Firms. All Firms Not Invited To Participate In Discussions Will Be Notified At This Time. Discussions May Be Held With The Most Highly Qualified Firms In The Form Determined To Be Most Advantageous And Economical By The Contracting Officer. The Form Of Discussions Will Be The Same For All Firms. For This Procurement, The Discussions Will Be Conducted Via Written Response. The Firms Invited To Participate In Discussions Will Be Notified By Email And Provided Further Instructions, To Include Any Questions Or Topics To Address. Following The Completion Of Discussions, The Firms Will Be Evaluated, Rated, And Ranked Based On The Selection Criteria For The Written Response. The Highest Rated Firm Will Be Selected, And The Solicitation Will Subsequently Be Issued. The Final Evaluation And Ranking Will Consider The Information Obtained Via Discussions For Each Firm. The Solicitation Will Be Issued To The Highest Rated Firm As A Request For Fee Proposal (rfp). A Site Visit Will Be Authorized For The Highest Rated Firm During The Negotiation Process. An Award Will Then Be Made As Long As The Negotiation Of Rates And Hours Leads To A Determination Of A Fair And Reasonable Final Contract Price. If Negotiations With The Highest Rated Firm Are Unsuccessful, The Firm Will Be Notified That Negotiations Have Been Terminated. Negotiations Will Then Be Initiated With The Next Highest Rated Firm, And So On Until Award Can Be Made.
5. Sf330 Selection Criteria: The Following Are Listed In Descending Order Of Importance: Primary Selection Criteria: Professional Qualifications (sections C Through E): Necessary For Satisfactory Performance Of Required Service. The Design Firm And A-e On Staff Representing The Project Or Signing Drawings In Each Discipline Must Be Licensed To Practice In Any One Of The United States Of America. Provide Professional License Numbers And/or Proof Of Licensure. The Evaluation Shall Consider The Specific Experience (minimum Of Five (5) Years) And Qualifications (i.e., Education, Training, Registration, Certifications, Overall Relevant Experience, And Longevity With The Firm As Full-time Employees) Of Personnel Proposed For Assignment To The Project, And Their Record Of Working Together As A Team When Evaluating Professional Qualifications. The Lead Designer In Each Discipline Must Be Registered But Does Not Have To Be Registered In The Particular State Where The Project Is Located. A Resume For Each Of These Key Positions Must Be Provided Identifying Their Specific Role, Via Section E In The Sf330. Key Positions And Disciplines Required For This Project Include, But Are Not Limited, To: Principal-in-charge Overall Project Manager. Architect Design Civil Design Structural Design Mechanical Design Electrical Design Plumbing Design Fire Protection Engineer (texas Licensed) Physical Security Specialist. Quality Assurance/quality (qa/qc) Control Manager Estimating Specifications Interior Design Other Offer Must Include The Following Statement Of Service-disabled Veteran-owned Small Business Sdvosb Compliance When Submitting The Personnel Proposed To Perform The Work Under This Requirement: I [signatory Authority]______________________, [company] __________________, Certify That The Sdvosb Prime Contractor Will Not Pay More Than 50% Of The Amount Paid By The Government To The Prime For Contract Performance To Firms That Are Not Certified Sdvosbs By The Small Business Association S Veteran Small Business Certification (vetcert) In Compliance Of Va Acquisition Regulation (vaar) 852.219-75. The Information Provided In Sections C Through E Of Sf 330 Will Be Used To Evaluate This Evaluation Factor. Do Not Include This Information In Section H, Unless It Is Pertinent To Support The Information Listed In The Other Sections. Specialized Experience And Technical Competence (sections F, G, And H): A/e Must Use Engineering Professionals With Proven Experience With Energy Center Designs Greater Than $20,000,000 Dollars On Va Facilities. Section G Will Used To Evaluate The Prior Experience Of The Prime Firm And Any Key Subcontractors Working Together On The Provided Relevant Projects. The Evaluation Will Also Consider Narratives Addressing The Following Topics In Section H. Simply Re-stating This List In Section H Will Not Be Sufficient. The Narrative Of How The Firm Addresses Each Of These Will Be Evaluated. The Management Approach The Coordination Of Disciplines And Subcontractors Quality Control Procedures, And Familiarity With Va Design Guides/manuals, Master Specifications And Other Applicable Standards. Capacity (section H): The Evaluation Will Consider The Firm S Ability To Meet The Schedule Of The Overall Project, As Well As The Available Capacity Of Key Disciplines To Perform The Work In The Re-quired Time. Provide The Available Capacity Of Key Disciplines By Providing Current Project Workload, Inclusive Of All Projects Awarded By The Va During The Previous Twelve (12) Months And The Full Potential Value Of Any Current Indefinite Delivery Con-tracts. Offeror Shall Clearly State Their Available Capacity Presenting Workload Percent-ages For The Key Disciplines And/or Team Members. Also, The Offeror Must Provide The Completion Percentages And Expected Completion Date For The Va Projects Awarded In The Previous Twelve (12) Months. The Information For This Factor Shall Be Provided In Section H Of The Sf 330. Please Ensure The Capacity Applies Toward The Team/personnel Provided In The Sf 330. Past Performance (section H): Past Performance On Contracts With Government Agencies And Private Industry In Terms Of Cost Control, Quality Of Work, And Compliance With Performance Schedules. Past Performance Will Be Evaluated For All Projects Provided In Section F. The Contractor Performance Assessment Rating System (cpars) Database Will Be Reviewed To Evaluate The Projects That Have A Cpars Entry. Cpars Are Not Required To Be Submitted With The Sf330 Submission. The Contract Number For The Project Must Be Submitted With Each Project In Section F So Cpars Can Be Reviewed In The Database. Please Note We Are Unable To Review Any Cpars From Other Federal Agencies, Outside Of The Va. For Any Project That Does Not Have Cpars Data Available, A Past Performance Questionnaire (ppq) Is Required To Be Submitted With The Sf330. The Ppq Should Be Rated And Signed By The Evaluator. In The Event That A Firm Does Not Receive A Requested Complete Ppq From An Evaluator Prior To The Time For Submission, The Firm Shall Submit The Partially Completed Ppq With Section 1 And The Evaluator Information In Section 2 Completed. Ensure A Poc Is Listed With The Project Title/contract Number. The Va Will Make Reasonable Attempts To Contact The Poc Upon Submission For Ppq Completion. Evaluations May Also Include Additional Performance Related From The Firm, Customer Inquiries, Government Databases, Publicly Available Sources, And Additional Projects In Cpars. The Government Reserves The Right To Contact Any Poc Listed On A Cpars Report Or Ppq. Evaluations Will Consider Superior Performance Ratings On Recently Completed Va Projects As Well As The Reputation And Standing Of The Firm And Its Principal Officials With Respect To Professional Performance, General Management, And Cooperativeness. If Appropriate, The Record Of Significant Claims Against The Firm Because Of Improper Or Incomplete Architectural And Engineering Services May Be Evaluated. Failure To Provide Requested Data, Accessible Points Of Contact, Or Valid Phone Numbers Could Result In A Firm Being Considered Less Qualified. All Projects Provided In The Sf 330 Must Be Completed By The Office/branch/individual Team Member Performing The Work Under This Contract. The Information For This Factor Shall Be Provided In Section H Of The Sf 330. For Ppqs, Please Utilize The Attached Ppq Document. Completed Ppqs Should Be Incorporated Into The Sf 330 Directly. Ppqs Should Not Be Submitted To The Vha Pcac Directly. Any Ppqs Will Not Be Counted Towards The Page Limitations For This Submission. However, Any Narratives Provided For Past Performance In Section H Will Be Counted Toward The Page Limit. Knowledge Of Locality (section H): To Include Specific Knowledge Of Certain Local Conditions Or Project Site Features, Such As Geological Features, Climatic Conditions, Working With And Local Construction Methods Or Local Laws And Regulations. The Information For This Factor Shall Be Provided In Section H Of The Sf 330. Note That The Intent Of This Factor Is To Showcase A Firm S Understanding Of The Site And Locality, And Not Where The Firm Is Located And How They Would Travel To The Site. Information Related To The Firm S Location, Shall Be Provided In Section H, Under Secondary Selection Criteria Factor 1. Experience In Construction Period Services (section H): Experience In Construction Period Services Must Be Demonstrated Via Project Experience. These May Be The Same Projects Identified Above In Factor 1; However, The Firm Shall Clearly Delineate The Types Of Construction Period Services Performed For Each. Project Descriptions Must Include Experience With: Solicitation Support Services, Professional Field Inspections During The Construction Period, Review Of Construction Submittals, Support In Answering Requests For Information During The Construction Period, Support Of Construction Contract Changes To Include Drafting Statements Of Work And Cost Estimates, Attendance At Weekly Conference Calls, Providing Minutes Of Meetings Between The Ae, Va, And Contractors, Pre-final Inspection Site Visits, Generation Of Punch-list Reports, Coordination With Commissioning Requirements And Production Of As-built Documentation. In Addition, The Firm Must Include Experience Addressing Unforeseen Conditions And Emergent Situations, Conducting Situation Evaluations And Make Midcourse Corrections. Include Description On How The Firm Can Be Proactive Or Responsive In These Situations. The Firm Shall Provide A Detailed Description Of Projects Worked That Illustrate Experience In These Ten Areas. Projects Must Be Within The Last Ten (10) Years. The Information For This Factor Shall Be Provided In Section H Of The Sf 330. Secondary Selection Criteria: Geographic Location - Location Of The Firm, As Measured By The Driving Distance (miles) Between The Offeror S Principal Business Location And: Sam Rayburn Memorial Veteran Center 1201 E. 9th Street Bonham, Texas 75418. Determination Of The Mileage Will Be Based On Google Maps (https://www.google.com/maps/dir/). The Secondary Selection Criterion Is Used As A Tiebreaker, If Necessary, In Ranking The Most Highly Qualified Firms Following The Completion Of The Sf330 Evaluations. The Secondary Selection Criterion Will Not Be Applied When Determining A Firm S Sf330 Submission Excellent, Good, Acceptable, Marginal, Or Unacceptable. The Information For This Factor Shall Be Provided In Section H Of The Sf330.
6. Discussions/written Response Selection Criteria: In Accordance With Far 36.602-3(c), Discussions Will Be Conducted In The Form Of A Written Response To Questions Developed By The Teb. The Selected Firms Will Be Invited To Respond To Written Questions Related To Criteria In The Sf330s. The Instructions For The Written Responses Will Be Provided To The Selected Firms Only. Each Selected Firm Will Be Evaluated Based On Their Responses To The Questions Asked. The Highest-ranked Firm Will Be Selected Based On Their Written Response. The Previous Sf330 Evaluations Are Not Applicable During The Written Response Phase Of The Selection Process.
7. Submission Criteria/requirements: The Below Information Contains The Instructions And Format That Shall Be Followed For The Submission Of The Sf 330, Statement Of Qualifications: Submission Contents Firms Are Required To Submit Two Documents: One Sf330, Architect/engineer Qualifications, And Any Attachments As A Pdf On The Sf330 Form (form Is Available On-line At Http://www.cfm.va.gov/contract/ae.asp). One Separate Document Containing The Following Information: Cage Code; Unique Entity Identifier (uei); Tax Id Number; E-mail Address(es) And Phone Number(s) Of The Primary Point(s) Of Contact; Address Of Firm For Correspondence; A Copy Of The Firm S Vetcert/vendor Information Pages Registration And Verification Format Of Submissions The Page Limitation Of The Sf330 Pdf Submission Shall Not Exceed A Total Of 35 Pages. This Includes Cover Letters, Title Pages, Section Divider Pages, Table Of Contents, Etc. Every Page In The Pdf Will Count Toward This Page Limit Except The Cpars Reports/ppqs And Part Ii Of The Sf330. Each Page Shall Be In In Times New Roman Font, Size 12, Single Spaced, On 8.5 X11 Paper With 1 Margins On All Sides. Any Pages In Excess Of The 35 Pages That Are Not Exempt Will Be Removed And Will Not Be Evaluated. Submit One (1) Sf 330, Statement Of Qualifications And Any Attachments, And One (1) Accompanying Document Containing The Above Sdvosb Information, Via Email To The Contracting Officer Rhonda.richardson5@va.gov. The Subject Line Of The Email Shall Read: Sf330 Submission; 36c77625r0010 Construct Bonham Energy Center, Design Project No: 549a4-23-600, Bonham, Tx The Sf 330 Pdf Shall Be Submitted In One Email And Have A File Size Shall Be No Larger Than 5 Mb. No Hard Copies Will Be Accepted. Firms Not Providing The Required Information May Not Be Evaluated. All Information Must Be Included In The Sf 330 Submission Package. Technical Questions: All Questions Shall Be Submitted To Rhonda.richardson5@va.gov With The Subject Line Sf330 Question - 36c77625r0010 Construct Bonham Energy Center, Design Project No: 549a4-23-600, Bonham, Tx
the Cutoff For Question Submission Is 2:00 Pm Ct On January 7, 2025. Questions Will Be Answered Through Amendment To The Pre-solicitation Notice Posted To Contracting Opportunities At Sam.gov. Submission Due Dates All Responses Are Due Via Email On Or Before January 28, 2025, At 10:00 Am Cst. Note: Sf 330 Submissions Received After The Date And Time Specified Will Not Be Considered. Late Proposal Rules Per Far 15.208 Will Be Followed For Late Submittals. All Emails Must Be Received By The Va Email Server By 10:00 Am Cst. The Time Will Not Be Based On When Firms Hit Send . Do Not Wait Until The Last Minute To Send Submissions. Errors In Email Address Spelling Or Attempts At Emailing Timely Will Not Recover A Late Submission. Other Information All Prime Firms Must Meet The Naics Code Requirement Specified In This Notice. The Contracting Officer Shall Verify The Naics Code In Vetcert Through The Small Business Administration (sba) And/or The System For Award Management (sam). Failure To Meet The Naics Code Requirement May Result In The Rejection Of The Sf330 Submission. Reminder: This Procurement Is A 100% Set-aside For Sdvosb Concerns. Offers Received From Other Than Sdvosb Concerns Will Not Be Considered. All Sdvosbs Must Be Listed As Verified By The Sba Veteran Small Business Certification (vetcert). Offerors Must Be Verified And Visible In The Sba Vetcert Database (veteran Small Business Certification (sba.gov)) At Time Of Submission Of Sf330 S, Written Responses, And Time Of Award. Failure To Be Both Visible And Verified At The Time Of Sf330s, Written Responses, And Time Of Award Will Result In The Offeror Being Deemed Unacceptable And Ineligible For Award. Note: As Of January 1, 2023, All Sdvosbs That Were Previously Verified By The Va Center For Verification And Evaluation (cve) Were Automatically Granted Certification By The Sba For The Remainder Of The Firm S Eligibility Period. The Sba Granted A One-time, One-year Extension Of Certification To Current Sdvosbs Verified By The Va As Of The Transfer Date On January 1, 2023. The Additional Year Was Added To The Existing Eligibility Period Of A Current Participant. New Applicants Certified By Sba After January 1, 2023, Received The Standard Three-year Certification Period. The Ndaa 2021 Granted A One-year Grace Period For Self-certified Sdvosbs That Ended January 1, 2024.â During The Grace Period, Self-certified Businesses Had One Year To File An Application For Sdvosb Certification And Could Continue To Rely On Their Self-certification To Compete For Non-va Sdvosb Set-aside Contracts. Self-certified Sdvosbs That Applied Before January 1, 2024, Will Maintain Their Eligibility Through The Expiration Of The Grace Period Until Sba Issues A Final Eligibility Decision. All Joint Ventures Must Be Sba Verified At Time Of Submission And Submit Agreements That Comply With 13cfr 125.15 Prior To Contract Award. It Is The Offeror S Responsibility To Check The Contract Opportunities Website At: Https://www.sam.gov/ For Any Revisions To This Announcement Prior To Submission Of Sf 330s. See Attached Document: Sow Construct Bonham Energy Center - Final 11-14-24. End Of Document
Closing Date28 Jan 2025
Tender AmountRefer Documents
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Civil And Construction...+3Building Construction, Consultancy Services, Civil And Architectural Services
United States
Details: This Is Not A Request For Proposal. This Is A Request For Standard Form (sf) 330 Architect-engineer Qualifications Packages Only. All Information Needed To Submit Sf 330 Documents Is Contained Herein. No Solicitation Package, Technical Information, Or Bidder/plan Holder List Will Be Issued. The Government Will Not Pay, Nor Reimburse, Any Costs Associated With Responding To This Request. The Government Is Under No Obligation To Award A Contract As A Result Of This Announcement. 1. General Information Veterans Health Administration (vha) Program Contracting Activity Central (pcac) Is Seeking Sources And Intends To Award A Firm Fixed Price Design Contract For Architect-engineering (a-e) Services For The Development Of Complete Construction Documents, Which Include Working Drawings, Specifications, And Reports, And Construction Period Services For Project #676-336 Fire Station Design-tomah Va Medical Center. The A-e Services Contract That Is Anticipated To Be Awarded Will Be Procured In Accordance With The Selection Of Architects And Engineers Statute [formerly Known As The Brooks Architect Engineer Act], Federal Acquisition Regulation (far) Subpart 36.6 Architectural And Engineering Services, Va Acquisition Regulation (vaar) 836.6, And Va Acquisition Manual (vaam) M836.6 Architect-engineer Services. In Accordance With Far 36.209, Construction Contracts With Architect-engineer Firms, No Contract For The Construction Of A Project Shall Be Awarded To The Firm That Designed The Project Or Its Subsidiaries Or Affiliates, Except With The Approval Of The Head Of The Agency Or Authorized Representative. 2. Project Information This Project Is A 100% Set-aside For Service-disabled Veteran-owned Small Business (sdvosb) Concerns. The Naics Code For This Procurement Is 541330 Engineering Services And The Annual Small Business Size Standard Is $25.5m. A Full Design Team Is Required To Complete This Project. The Va Expects To Award The Anticipated A-e Contract By Late March 2025. The Anticipated Period Of Performance For Completion Of Design Is 160 Calendar Days After Notice Of Award (noa). The Vaar Magnitude Of Construction Is Between $5,000,000 And $10,000,000. Please Note That The 160-calendar-day Period Of Performance For The Design Completion Begins With The Issuance Of The Noa And That A Notice To Proceed (ntp) Will Not Be Issued For The Completion Of A Design Project. 3. A-e Selection Process Firms Submitting Sf 330s In Response To This Announcement, Not Later Than The Closing Date And Time Specified Herein And In Accordance With Submission Requirements, Will Be Considered For Evaluation. The Selection Will Be Made As Follows: Sf 330s Will Be Evaluated In Accordance With The Primary Selection Criteria As Stated In This Pre-solicitation Notice. These Evaluations Will Determine The Most Highly Qualified Firms For This Particular Requirement. In Accordance With Far 36.602-3(c), At Least Three Of The Most Highly Qualified Firms Will Then Be Notified Of The Government S Intent To Hold Discussions. All Firms Not Invited To Participate In Discussions Will Be Notified At This Time. In Accordance With Far 36.607(b), Any Requested Debriefings Of Successful And Unsuccessful Firms Will Be Held After Final Selection Has Taken Place And Will Be Conducted, To The Extent Practicable, In Accordance With 15.503, 15.506(b) Through (f), And 15.507(c). Note That 15.506(d)(2) Through (d)(5) Do Not Apply To Architect-engineer Contracts. Discussions Will Be Held With The Most Highly Qualified Firms In The Form Of Written Responses. The Firms Invited To Participate In Discussions Will Be Notified By Email And Provided Further Instructions, Including Any Questions Or Topics To Address. Following The Completion Of Discussions, The Firms Will Be Evaluated And Ranked Based On The Primary And (if Necessary) Secondary Selection Criteria. The Final Evaluation And Ranking Will Consider The Sf 330 Submission For Each Firm, As Well As Additional Information Obtained Via Discussions. The Highest Rated Firm Will Be Selected To Receive The Solicitation And Engage In Negotiations. The Solicitation Will Be Issued To The Highest Rated Firm As A Request For Fee Proposal (rfp). All Sow Attachments And Site-specific Documentation Will Be Provided To The Highest Rated Firm With The Rfp. A Site Visit Will Be Authorized During The Negotiation Process. An Award Will Then Be Made As Long As The Negotiation Of Rates And Hours Leads To A Fair And Reasonable Determination Of The Final Contract Price. If Negotiations With The Highest Rated Firm Are Unsuccessful, The Firm Will Be Notified That Negotiations Have Been Terminated. Negotiations Will Then Be Initiated With The Next Highest Rated Firm, And So On Until Award Can Be Made. 4. Selection Criteria: Firms Responding To This Notice Will Be Evaluated And Ranked Using The Primary And Secondary Selection Criteria Listed Below. The Factors Are Listed In Descending Order Of Importance. The Evaluation Will Consider How Each Factor Is Addressed And How It Is Formatted To Coincide With The Selection Criteria. Primary Selection Criteria: Professional Qualifications: Professional Qualifications Necessary For Satisfactory Performance Of Required Service. The A-e Shall Demonstrate They Are Able To Sign And Stamp Each Drawing By Individuals Licensed In Any State In The United States For The Key Positions Listed Below. Provide Professional License Numbers And/or Proof Of Licensure. The Evaluation Shall Consider The Specific Experience (minimum Of Five Years) And Qualifications (i.e., Education, Training, Registration, Certifications, Overall Relevant Experience, And Longevity With The Firm As Full-time Employees) Of Personnel Proposed For Assignment To The Project. The Lead Designer In Each Discipline Must Be Registered But Does Not Have To Be Registered In The Particular State Where The Project Is Located. Disciplines Requiring A Florida License Include Civil/structural And Hazardous Material Abatement/industrial Hygiene. A Resume For Each Of These Key Positions Must Be Provided In Section E Of The Sf330. Key Positions And Disciplines Required For This Project Include, But Are Not Limited To: Architect (leed Certification/us Green Build Council Certification) Cost Estimator Civil Engineer Electrical Engineer Environmental Engineer Fire Protection Engineer Mechanical Engineer Plumbing Engineer Project Manager Quality Assurance Manager Structural Engineer Physical Security Specialists Commissioning Agent Offeror Must Include The Following Statement Of Sdvosb Compliance When Submitting The Personnel Proposed To Perform The Work Under This Requirement: I, [signatory Authority], Of [company Name], Certify That The Sdvosb Prime Contractor Will Not Pay More Than 50% Of The Amount Paid By The Government To The Prime For Contract Performance To Firms That Are Not Certified Sdvosbs Listed In The Sba Certification Database In Compliance With Vaar 852.219-73. The Information Provided In Sections C Through E Of The Sf 330 Will Be Used To Evaluate This Factor. Do Not Include This Information In Section H Unless It Is Pertinent To Support The Information Listed In The Other Sections. Specialized Experience And Technical Competence: Specialized Experience And Technical Competence In The Design And Construction Period Services Shall Be Provided For Network Infrastructure Installation, Renovations, Or Upgrades. Projects Experience Should Include Upgrading Large Scale (multi-building With Multiple Generational Oit Systems) Fiber Optics, Data Cable, Structured Cabling, Electrical Distribution Design, Electrical Upgrades, Uninterruptable Power Systems (ups), Electrical Bonding, Building Management Systems/building Automation Systems (bms/bas), Hvac, It Room Renovations/expansion/relocations, Data Centers/server Rooms Reconfiguration, And Physical Security Upgrades, Duct Bank And Direct Boring Operations. Other Specialized Experience To Provide Should Include Experience In Critical Path Scheduling, Fire Protection, Construction Infection Control Protocols, Energy Conservation, Transition, And Sustainable Design Practices. Submissions Shall Include No More And No Less Than Five (5) Recent And Relevant Government And Private Experience Projects Similar In Size, Scope, And Complexity, And Experience With The Type Of Projects/competence Above. Relevant Is Defined As Those Task Requirements Identified In The Statement Of Work. Recent Is Defined As Services Provided Within The Past Five (5) Years. Include The Following For Each Submitted Project: Project Title And Location Detailed Narrative Describing The Scope Of Services Provided, Including The Type Of Work Performed By The Offeror And Its Role In The Project (i.e., Prime Contractor, Teaming Partner, Or Subcontractor) Project Owner, Owner S Point Of Contact Including Telephone Number And Email Address. Services & Deliverables Provided Under The Contract/task Order. Period Of Performance, Including Start And Completion Dates Total Dollar Value Of The Project Ae Cost Estimate Vs. Actual Construction Cost Contract Number Associated With The Project. The Information Provided In Section F Of The Sf 330 Will Be Used To Evaluate Relevant Specialized Experience And Technical Competence. Any Projects Submitted By An Offeror That Exceed The Limit Will Not Be Considered During The Evaluation. The Information Provided In Section G Of The Sf 330 Will Be Used To Evaluate The Prior Experience Of The Prime Firm And Any Key Subcontractors Working Together On The Provided Relevant Projects. The Offeror Must Include Narratives Of How The Firm Addresses Each Of The Following Topics In Section H. Simply Restating This List In Section H Will Not Be Sufficient. The Management Approaches. The Coordination Of Disciplines And Subcontractors Quality Control Procedures, And Familiarity With Va Design Guides/manuals, Master Specifications, And Other Applicable Standards. Capacity: The Evaluation Will Consider The Firm S Ability To Meet The Schedule Of The Overall Project, As Well As The Available Capacity Of Key Disciplines To Perform The Work In The Required Time. Provide The Available Capacity Of Key Disciplines By Providing Current Project Workload, Inclusive Of All Projects Awarded By The Va, Any Federal Agency, And Private Sector, During The Previous Twelve (12) Months Or Any Active Projects At Pcac. Include The Full Potential Value Of Any Current Indefinite Delivery Contracts The Prime Firm Has Been Awarded From Any Source. Offeror Shall Clearly State Their Available Capacity Presenting Workload Percentages For The Key Disciplines And/or Team Members. Also, The Offeror Must Provide The Award Date, Completion Percentages, And Expected Completion Date For The Va Projects Awarded In The Previous Twelve (12) Months Or Active At Pcac. The Information For This Factor Must Be Provided In Section H Of The Sf 330. Please Ensure The Capacity Applies Toward The Proposed Team/personnel Provided In The Sf 330. Past Performance: Past Performance Will Be Evaluated On Contracts With Government Agencies And Private Industry In Terms Of Cost Control, Quality Of Work, And Compliance With Performance Schedules. Past Performance Will Be Evaluated For All Projects Provided In Section F. The Contractor Performance Assessment Reporting System (cpars) Database Will Be Reviewed To Evaluate The Projects That Have A Va Cpars Entry. Va Cpars Are Not Required To Be Submitted With The Sf330 Submission. The Contract Number For The Project Must Be Submitted For Each Project Provided In Section F So Cpars Can Be Reviewed In The Database. Please Note We Are Unable To Review Any Cpars From Other Federal Agencies Outside Of The Va. For Any Project That Does Not Have Va Cpars Data Available, A Past Performance Questionnaire (ppq) Is Required To Be Submitted With The Sf330. If The Firm (prime Or Subcontractor) Was Not The Prime Contractor On Any Project Submitted In The Sf330, A Ppq Must Be Submitted Listing Their Specific Role (key Disciplines) As A Subcontractor. The Ppq Should Be Rated And Signed By The Evaluator. In The Event That A Firm Does Not Receive A Completed Ppq Requested From An Evaluator Prior To The Time For Submission, The Firm Shall Submit The Partially Completed Ppq With Section 1 And The Evaluator Information In Section 2 Completed. Ensure A Poc Is Listed With The Project Title/contract Number. The Va Will Make Reasonable Attempts To Contact The Poc Upon Submission For Ppq Completion. The Government May Consider Additional Performance Related Information Regarding The Firm, To Include Customer Inquiries, Government Databases, Publicly Available Sources, And Additional Projects In Cpars. The Government Reserves The Right To Contact Any Poc Listed On A Cpars Report Or Ppq. If Appropriate, The Record Of Significant Claims Against The Firm Because Of Improper Or Incomplete Architectural And Engineering Services May Be Evaluated. Failure To Provide Requested Data, Accessible Points Of Contact, Or Valid Phone Numbers Will Result In A Firm Being Considered Less Qualified. The Information For This Factor Must Be Provided In Section H Of The Sf 330. For Ppqs, Please Utilize The Attached Ppq Document. Completed Ppqs Should Be Incorporated Into The Sf 330. Ppqs Should Not Be Submitted To Vha Pcac Directly. Any Ppqs Will Not Be Counted Towards The Page Limitation For This Submission. However, Any Narratives Provided For Past Performance In Section H Will Be Counted Toward The Page Limit. Knowledge Of Locality: Demonstrate And Describe Experience In The Local Area And The Specific Knowledge Of Certain Local Conditions Or Project Site Features The Experience Provided. This Description May Include (if Applicable): Any Prime Firm Or Subcontractor Experience Within The Visn Or At The Vamc State Or Local Construction Codes, Laws, Or Regulations Climate And Seismic Related Conditions Or Features The Information For This Factor Must Be Provided In Section H Of The Sf 330. Note That The Intent Of This Factor Is To Showcase A Firm S Understanding Of The Site And Locality, And Not Where The Firm Is Located, How Far Away The Firm/branch Office Is From The Site, And How They Would Travel To The Site. Information Related To The Firm S Location Shall Instead Be Provided In Section H Under Secondary Selection Criterion Factor 1, Geographic Location. See Below. Experience In Construction Period Services: Experience In Construction Period Services Must Be Demonstrated Via Project Experience. These May Be The Same Projects Identified Above In Factor 1; However, The Firm Shall Clearly Delineate The Types Of Construction Period Services Performed For Each. Refer To The Statement Of Work For Review Timeline Expectations. Project Descriptions Must Include Experience With: Solicitation Support Services, Professional Field Inspections During The Construction Period Coordination With Commissioning Requirements Review Of Construction Submittals Support In Answering Requests For Information During The Construction Period. Support Of Construction Contract Changes To Include Drafting Statements Of Work And Cost Estimates. Attendance At Weekly Conference Calls Providing Minutes Of Meetings Between The Ae, Va, And Contractors Pre-final Inspection Site Visits Generation Of Punch-list Reports, And Production Of As-built Documentation. The Firm Shall Provide A Detailed Description Of Projects Worked That Illustrate Experience In These Areas. Projects Must Be Within The Last Ten (10) Years. In Addition, The Firm Must Include A Description Of Experience Addressing Unforeseen Conditions And Emergent Situations, Conducting Situation Evaluations, And Making Midcourse Corrections. Include Description On How The Firm Can Be Proactive Or Responsive In These Situations. The Information For This Factor Must Be Provided In Section H Of The Sf 330. Secondary Selection Criterion*: Geographic Location. Location Of The Firm, As Measured By The Driving Distance (miles) Between The Offeror S Principal Business Location And The Tomah Va Medical Center 500 E Veterans Street, Tomah, Wi. 54660. . Determination Of The Mileage Will Be Based On Google Maps (https://www.google.com/maps/dir/). *the Secondary Selection Criterion Is Used As A Tiebreaker, If Necessary, In Ranking The Most Highly Qualified Firms Following The Completion Of Discussions. The Secondary Selection Criterion Will Not Be Applied When Determining A Firm S Sf 330 Submission Highly Qualified Or Not Highly Qualified. 5. Submission Requirements: The Below Information Contains The Instructions And Format That Must Be Followed For The Submission Of The Sf 330 Statement Of Qualifications: Submit One (1) Sf 330 Statement Of Qualifications To Contract Specialist Johnna Mcgraw At Johnna.mcgraw@va.gov . This Must Include Parts I And Ii And Any Applicable Attachments. The Submission Must Include The Sf 330, Architect-engineer Qualifications (form Is Available Online At Https://www.gsa.gov/reference/forms/architectengineer-qualifications). The Sf 330 Submission Is Due By January 10th 2025 At 1pm Est. The Sf 330 Must Be Submitted In One Email And Have A File Size No Larger Than 5 Mb. No Hard Copies Will Be Accepted. The Subject Line Of The Email Must Read: Sf 330 Submission Fire Station Design- Tomah Wi. The Sf 330 Submission Must Not Exceed A Total Of 50 Pages. This Includes Title Page, Table Of Contents, And Any Other Relevant Information. Any Pages Submitted By An Offeror That Exceed The Limit Will Not Be Considered During The Evaluation. Each Page Must Be In Arial Size 12 Font, Single Spaced. Part Ii Of The Sf 330 And Any Cpars Or Ppqs Will Not Count Toward The Page Limitation. A Ppq Obtained For Another Sf 330 Submission May Be Submitted For This Project. However, If Significant Portions Of The Project Have Been Completed Since The Ppq Was Filled Out, A New Ppq Should Be Submitted To Accurately Assess The Project. Firms Must Include The Following Information In Section B Of The Sf 330 Submission: 1) Sam Unique Entity Identifier 2) Tax Id Number 3) Cage Code 4) Primary Point Of Contact S Email Address And Phone Number. All Questions Must Be Submitted To Johnna Mcgraw With The Subject Line Sf 330 Questions Fire Station Design-tomah Wi. The Cutoff For Question Submission Is 1:00 Pm Est On December 16th, 2024. Questions Will Be Answered Through Modification To The Pre-sol Notice Posted To Contract Opportunities At Sam.gov. This Procurement Is A 100% Set-aside For Sdvosb Concerns. Offers Received From Other Than Sdvosbs Will Not Be Considered. Offerors Must Be Certified As Sdvosbs By The U.s. Small Business Administration (sba) And Visible In The Veteran Small Business Certification (vetcert) Database (https://veterans.certify.sba.gov/) At The Time Of Sf 330 Submission, Written Response Submission, And Award. Failure To Be Certified In The Vetcert Database At These Times Will Result In The Offeror Being Deemed Ineligible For Award. All Joint Ventures Must Be Sba Certified At The Time Of Sf 330 Submission, Written Response Submission, And Award And Must Submit Agreements That Comply With 13 Cfr 128.402 Prior To Contract Award. All Prime Firms Must Meet The Naics Code Requirement Specified In This Notice. The Contracting Officer Will Verify The Naics Code In Vetcert. Failure To Meet The Naics Code Requirement May Result In The Rejection Of The Sf 330 Submission. Sf 330 Submissions Received After The Date And Time Specified Will Not Be Considered. Late Proposal Rules Per Far 15.208 Will Be Followed For Late Submittals. Firms Not Providing The Required Information May Not Be Evaluated. All Information Must Be Included In The Sf 330 Submission Package. It Is The Offeror S Responsibility To Check The Contract Opportunities Website At Sam.gov For Any Revisions To This Announcement Prior To Submitting Their Sf 330.
Closing Soon10 Jan 2025
Tender AmountRefer Documents
City Government Iligan Tender
Civil And Construction...+1Building Construction
Philippines
Details: Description Invitation To Bid The Iligan City Government Bids And Awards Committee (bac), Through General Fund-20% / Dev. Fund, Intend To Apply The Sum Of P 1,622,577.91 Being The Approved Budget For The Contract (abc) To Payments Under The Contract For Improvement Of Brgy. Health Center, Temp. Room Extension - Iligan Health Center, Brgy. Del Carmen, Iligan City With Project No. Cb(b)-25-002 (ceo-infra). Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. The Iligan City Government Bids And Awards Committee Now Invites For The Supply And Delivery Of Items Below-stated: Particulars Improvement Of Brgy. Health Center, Temp. Room Extension - Iligan Health Center, Brgy. Del Carmen, Iligan City General Requirements • Installation Of Project Billboard • Occupational Safety And Health Program • Mobilization And Demobilization Removal Of Structures And Obstruction • Remove And Replace Ceiling Board At Abtc And Roof Eaves • Demolish Chb Wall Partition At Utility Access And Female Toilet • Remove And Replace Doors And Jambs • Demolish Some Chb Wall Partition For Door Opening At Doffing Station Level 01 & 02 • Demolish Plant Box At Receiving Area For Stairs Earthworks • Excavation Work For Pedestal Footings • Gravel Bedding For Pedestal Footings • Backfilling Of Common Soil Using Excavated Soil Must Be Compacted Layer By Layer Concrete Work, Formwork & Scaffolding • Pedestal Column And Zocalo For Waiting Area And Receiving Area • Slab For Waiting Area And Receiving Area • Sputum Collection At Injection Area And Laboratory Steel Reinforcements • Pedestal Column And Zocalo For Waiting Area And Receiving Area • Slab For Waiting Area And Receiving Area • Masonry Wall Reinforcement • Sputum Collection At Injection Area And Laboratory Steel Works • Rectangular Tube 50 X 75 X 1.2mm For Purlins At Waiting Area And Receiving Area • Rectangular Tube 50 X 100 X 1.2mm For Rafter And Column At Waiting Area And Receiving Area Masonry & Plastering Works • 100mm Thk. Chb Wall Partition For Counseling Room • 100mm Thk. Chb Wall For Additional Pwd Toilet, Female Toilet And Sputum Collection Ceiling Works • Replace Ceiling Board At Tb Dots/ Is Dots With 4.5mm Thk. Fiber Cement Board • Replace Ceiling Board At Roof Eaves With Pvc Ceiling Panel Dry Wall Partition • Install Drywall Partition At: - File/ Stock Room & Medical Supplies Room - Examination/ Treatment Area - Arv & Supplies Storage Area - Consultation Room And Laboratory Roofing Works • Install 3mm Polycarbonate Solid Sheet For Roofing At Waiting Area And Receiving Area Tile Works • Installation Of 300mm X 300mm Ceramic Floor Tiles (non-skid) At Additional Pwd Toilet Floor And Female Toilet • Installation Of 300mm X 300mm Ceramic Wall Tiles (glossy) At Additional Cr Wall, Female Toilet And Sink Electrical Works • Remove Lighting And Wirings In The Two Rooms To Be Renovated • Installation Of Conduits ,junction Box ,utility Box • Installation Of New Electrical Wire ,switches , Aircon Outlet • Installation Of Lighting Fixture In Its New Location According The Electrical Plan (note Use The Old Lighting Fixture) • Lighting Circuits Must Be Connect In Circuit No. 1 And Circuit No. 5 As Refer To The Electrical Plan • Additional Aircon Outlet Installed Must Be Connected To Electrical Panelboard Spare Plumbing Works • Pipes (water, Waste And Soil) For Additional Pwd Toilet, Female Toilet And Sputum Collection • Replace P-trap In Every Sink • Installation Of Water Closet, Lavatory And Faucet • Install Of Grab Bar Ss 304 L 49 X W 7.5 X H 6 Cm, Grab Bar,vertical Wall Support 32mmø Ss304 Painting Works • Repaint Existing Interior Ceiling Board • New Paint For Ceiling Board At Abtc (tb Dots/ Is Dots) • New Paint For Interior Chb Wall Partition At Counseling Room And Additional Pwd And Female Toilet • Paint Steel Rafter, Purlins And Steel Columns • Seal Joints At Drywall And Ceiling Using Gypsum Putty Doors And Windows • W1- 2250mm X 1500mm Analok- Aluminum Framed, 6mm Thk. Fixed Glass Window • D1- 800mm X 2100mm Wooden Panel Door (kiln Dried) With 50 X 150 Mm Door Jamb And Complete Accessories • D2- 1300mm X 2100mm Double Swing Flush Door With Vision Glass ,50 X 150 Mm Door Jamb And Complete Accessories • D3- 1000mm X 2100mm Wooden Flush Door With Exhaust, 50 X 150 Mm Door Jamb And Complete Accessories • D4- 600mm X 2100mm Wooden Flush Door With Exhaust, 50 X 150 Mm Door Jamb And Complete Accessories • D5- 1?00mm X 2650mm Analok- Aluminum Framed,6mm Thk. Sliding Glass Door With Complete Accessories • D6- 1600mm X2650mm Accordion Door With Complete Accessories • Dw1- 2200mm X 2650mm Analok- Aluminum Framed, 6mm Thk. Swing Glass Door With Transom & Complete Accessories • Dw2- 2350mm X 2650mm Analok- Aluminum Framed, 6mm Thk. Swing Glass Door With Transom & Complete Accessories • Dw3- 2375mm X 2650mm Analok- Aluminum Framed, 6mm Thk. Swing Glass Door With Transom & Complete Accessories • Dw4- 4850mm X 2650mm Analok- Aluminum Framed,6mm Thk. Swing Glass Door With Transom & Complete Accessories I. General Requirements A. Project Billboard (q = 1.00 Lot) Includes 4' X 8' Tarpaulin, 8' X 8' Tarpaulin, Rx 3"x 14" Coco Lumber, 2"x 3"x10" Coco Lumber, 2"x 2" X8" Coco Lumber, Assorted Sizes C.w. Nails. B. Occupational Safety And Health Program (q = 1.00 Lot) Includes Safety Shoes, Safety Helmet, Safety Gloves, Specialized Ppe. C. Mobilization / Demobilization (q = 1.00 Lot) Ii. Removal Of Structures And Obstruction (q = 1.00 Lot) Includes Remove And Replace Ceiling Board At Abtc (new Tb Dots/is Dots) And Roof Eaves, Demolish Chb Wall Partition At Utility Access And Female Toilet, Remove And Replace Doors And Jambs, Demolish Some Chb Wall Partition For Door Opening At Doffing Station Level 01 & 02, Demolish Plant Box At Receiving Area For Stairs. Iii. Earthworks (q = 2.88 Cu.m.) Includes Volume To Be Excavated, Volume Of Gravel Bedding. Iv. Concrete Work, Formwork & Scaffolding (q = 3.45 Cu.m.) Includes Portland Cement, Washed Sand, Washed Gravel, Marine Plywood 12mm Thk. X 4' X 8', 2" X 3" X 8' Coco Lumber, 2" X 2" X 8' Coco Lumber, Assorted Sizes C.w. Nails. V. Steel Reinforcements (q = 312.42 Kgs.) Includes 10mm Ø Dsb X 6m, 12 Mm Ø Dsb X 6m, No. 16 G.i. Tie Wire. Vi. Steel Works (q = 299.56 Kgs.) Includes Rectangular Tube 50 X 75 X 1.2 X 6000 Mm, Rectangular Tube 50 X 100 X 1.2 X 6000 Mm, Welding Rod (6011), Baseplate 12mm X 8"x16", 1/2" X 4" Expansion Bolt, Stud Anchor M8x75mm, 4" Cutting Disk, 4" Grinding Disk. Vii. Masonry & Plastering Works (q = 43.27 Sq.m.) Includes 4" Chb 700psi, Portland Cement, Washed Sand,injectable Chemical Anchor. Viii. Doors And Windows (q = 37.00 Set) Includes Wl: 2250mm X 1500mm Analok- Aluminum Framed, 6mm Thk. Fixed Glass Window; Dl: 800mm X 2100mm Wooden Panel Door (kiln Dried) With 50 X 150 Mm Door Jamb And Complete Accessories; D2: 1200mm X 2100mm Double Swing Flush Door With Vision Glass , 50 X 150 Mm Door Jamb And Complete Accessories; D3: 900mm X 2100mm Wooden Flush Door With Exhaust, 50 X 150 Mm Door Jamb And Complete Accessories; D4: 600mm X 2100mm Wooden Flush Door With Exhaust, 50 X 150 Mm Door Jamb And Complete Accessories; Ds: 1700mm X 2650mm Analok- Aluminum Framed, 6mm Thk. Sliding Glass Door With Complete Accessories; D6: 1600mm X2650mm Accordion Door With Complete Accessories; D7: 900mm X2100mm Wooden Flush Door W/50 X 150 Mm Door Jamb And Ss Lick Plate With Complete Accessories; Dwl: 2200mm X 2650mm Analok- Aluminum Framed, 6mm Thk. Swing Glass Door With Transom & Complete Accessories; Dw2: 2350mm X 2650mm Analok- Aluminum Framed, 6mm Thk. Swing Glass Door With Transom & Complete Accessories; Dw3: 2375mm X 2650mm Analok- Aluminum Framed, 6mm Thk. Swing Glass Door With Transom & Complete Accessories; Dw4: 4850mm X 2650mm Analok- Aluminum Framed, 6mm Thk. Swing Glass Door With Transom & Complete Accessories; Ss Lever Type Lockset, Heavy Duty; Ss Knob Type Lockset, Heavy Duty. Ix. Painting Works (q = 372.77 Sq.m.) Includes Skim Coat (20kg/pack), Pennacoat Rat Latex, Masonry Putty, Red Oxide Primer, Quick Drying Enamel, Paint Thinner, Paint Roller 7" W/ Paint Tray, Paint Brush 2-1/2 ", Sand Paper (assorted Sizes), Tape Fiberglass Mesh (48mm X 30m), Gypsum Putty (5kg/gal). X. Ceiling Works (q = 177.65 Sq.m.) Includes 4.5mm Thk X 4" X 8" Ficem Board, Blind Rivets, 1000pcs/box; Riveter. Xi. Dry Wall Partition (q = 90.09 Sq.m.) Includes 4.5mm Thk X 4' X 8' Ficem Board; Metal Studs, 0.50mm Thk. X 2" X 3" X 2" X 3.00m; Metal Tracks, 0.50mm Thk. X 2" X 3" X 2" X 3.00m; Hardiflex Screw ( Rat Head) #7x 25mm (500 Pcs); Blind Rivets, 1000pcs/box. Xii.roofing Works ( Q = 27.05 Sq.m.) Includes 4' X 8' X 3mm Polycarbonate Solid Sheet, Analok Flat Bar 1/8" X 1" X 16ft, Tek Screw 12 X 65mm (100pcs). Xiii.tile Works (q = 27.71 Sq.m.) Includes 300mm X 300mm Ceramic Floor Tiles (non-skid), 300mm X 300mm Ceramic Wall Tiles, Tile Grout (2kg), Tile Adhessive 25kg (heavy Duty), Portland Cement, Washed Sand, Diamond Cutter Wheel. Xiv. Electrical Works ( Q = 1.00 Lot) Includes Led Panel Light 20w 30x30cm Daylight Recessed Type 230vac; Single Gang Switch 230v; Three Gang Switch 230v; T8 Led Tube Light,18w,43x1220x31mm,g13,single Ended W/ Fixture; Junction Box; Utility Box; Aircon Outlet 20a 230vac; 3.smm2 Thwn-2 Stranded Copper Wire; 8.0mm 2 Thwn-2 Stranded Copper Wire; Electrical Pvc 20mm Schedule 40; Electrical Tape 0.16mmx19mmx16m; Circuit Breaker 50at Bolt On 10kaic. Xv.plumbing Works (q = 1.00 Lot) Includes Stainless Steel Lavatory Faucet, Heavy Duty; Two Piece Water Closet, 705x400x775mm; Lavatory , 500x655x835mm; Stainless Sink, Heavy Duty; Grab Bar Ss 304 L 49 X W 7.5 X H 6 Cm; Grab Bar Vertical Wall Support 32mm0 Ss304; Floor Drain 100x150xx2.7mm; 4" Dia. Pvc Wye; 4" Dia. Pvc Coupling; 4" Dia. Pvc Clean Out; 4" Dia. Pvc Elbow, 1/8 Bend; 4" Dia. X 10' Pvc Pipe, S-1000; 2" Dia. Pvc P-trap; 2" Dia. Pvc Wye; 2" Dia. Pvc Elbow, 1/8 Bend; 2" Dia. Pvc Elbow, 1/4 Bend; 2" Dia. X 10' Pvc Pipe, S-1000; 3 Way Angle Valve; Pvc Cement, 400cc; 1/2" Dia. G.i. Elbow; 1/2" Dia. G.i.tee; 1/2" Dia. G.i. Coupling; 1/ 2" Dia. X 20' G.i. Pipe; Teflon Tape (big). Approved Budget For The Contract (abc): P 1,622,577.91 Required Bid Security: 2% Of The Abc If Cash, Manager’s Check; Bank Draft/guarantee, Irrevocable Letter Of Credit Confirmed Or Authenticated By A Universal Or Commercial Bank; And 5% Of The Abc If Surety Bond Callable Upon Demand Issued By A Surety Or Insurance Company Duly Certified By The Insurance Commission As Authorized To Issue Such Security Delivery Period Is Within Ninety (90) Calendar Days From Receipt Of Notice To Proceed. Bidders Should Have Completed, Within Three (3) Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii. Instruction To Bidders. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The Implementing Rules And Regulations (irr) Of Republic Act (ra) 9184, Otherwise Known As The “government Procurement Reform Act”. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra 5183 And Subject To Commonwealth Act 138. Interested Bidders May Obtain Further Information From Iligan City Government And Inspect The Bidding Documents During Office Hours From 8:00 A.m. – 12:00 P.m. And 1:00 P.m. – 5:00 P.m. At The Bac Office, Room 205, Left Wing, 2nd Floor, Sp Bldg., Buhanginan Hills, Palao, Iligan City. The Complete Schedule Of Activities Is Listed, As Follows: Activities Schedule 1. Issuance Of Bid Documents: January 7 – January 28, 2025 – 8:00 A.m. At Room 205, Left Wing, 2nd Floor, Sp Bldg., Buhanginan Hills, Palao, Iligan City. 2. Pre-bid Conference: January 14, 2025 – 9:30 A.m. At Casimero P. Cabigon Hall, 2nd Floor City Hall Main Bldg., Buhanginan Hills, Pala-o, Iligan City 3. Submission Of Bids: January 28, 2025 – 9:30 A.m. At Casimero P. Cabigon Hall, 2nd Floor City Hall Main Bldg., Buhanginan Hills, Pala-o, Iligan City 4 . Opening Of Bids: January 28, 2025 – 9:30 A.m. At Casimero P. Cabigon Hall, 2nd Floor City Hall Main Bldg., Buhanginan Hills, Pala-o, Iligan City A Complete Set Of Bidding Documents Will Be Available To Prospective Bidders Upon Payment Of A Non-refundable Amount Of P 5,000.00 To The Iligan City Government Cashier, At The Bac Office, Room 205, Left Wing, 2nd Floor, Sp Bldg., Buhanginan Hills, Palao, Iligan City.the Iligan City Government Reserves The Right To Accept Or Reject Any Bid, To Annul The Bidding Process, And To Reject All Bids At Any Time Prior To Contract Award, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. Furthermore, The City Government Of Iligan Assumes No Responsibility Whatsoever To Compensate Or Indemnify Bidders For Any Expense Or Loss Incurred In The Preparation And Submission Of The Eligibility Statements And Bids. Approved By: (signed)darwin J. Manubag, Phd. Bac Chairman Date Of Advertisement/posting: January 7, 2025 Place Of Posting/advertisement: City Hall/ibjt Bulletin Boards, Iligan Official Website, Phil-geps Itb No. 25-002 (ceo-infra)
Closing Date28 Jan 2025
Tender AmountPHP 1.6 Million (USD 27.9 K)
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Civil And Construction...+2Consultancy Services, Civil And Architectural Services
United States
Details: Presolicitation Notice
presolicitation Notice
page 11 Of 11
presolicitation Notice
*=required Field
presolicitation Notice
page 1 Of 11
this Is Not A Request For Proposal. This Is A Request For Standard Form (sf) 330 Architect-engineer Qualifications Packages Only. All Information Needed To Submit Sf 330 Documents Is Contained Herein. No Solicitation Package, Technical Information, Or Bidder/plan Holder List Will Be Issued. The Government Will Not Pay, Nor Reimburse Any Costs Associated With Responding To This Request. The Government Is Under No Obligation To Award A Contract As A Result Of This Announcement.
general Information
veterans Health Administration (vha) Regional Procurement Office West (rpow) Network Contracting Office 20 (nco20) Is Seeking Sources And Intends To Award A Firm Fixed Price Design Contract For Architect-engineering (a-e) Services For The Development Of Complete Construction Documents, Which Include Working Drawings, Specifications, And Reports, And Construction Period Services For Project # 668-25-102 Replace Asphalt, Drywells, And Sidewalks At The Mann-grandstaff Vamc In Spokane, Wa. The A-e Services Contract That Is Anticipated To Be Awarded Will Be Procured In Accordance With The Selection Of Architects And Engineers Statute [formerly Known As The Brooks Architect Engineer Act], Federal Acquisition Regulation (far) Subpart 36.6 Architectural And Engineering Services, Va Acquisition Regulation (vaar) 836.6, And Va Acquisition Manual (vaam) M836.6 Architect-engineer Services. In Accordance With Far 36.209, Construction Contracts With Architect-engineer Firms, No Contract For The Construction Of A Project Shall Be Awarded To The Firm That Designed The Project Or Its Subsidiaries Or Affiliates, Except With The Approval Of The Head Of The Agency Or Authorized Representative.
project Information
this Project Is A 100% Set-aside For Service-disabled Veteran-owned Small Business (sdvosb) Concerns. The Naics Code For This Procurement Is 541330 Engineering Services And The Annual Small Business Size Standard Is $25.5m. A Full Design Team Is Required To Complete This Project. The Va Expects To Award The Anticipated A-e Contract In Late March 2025.
the Anticipated Period Of Performance For Completion Of Design Is 255 Calendar Days After Notice Of Award (noa). The Vaar Magnitude Of Construction Is Between $5,000,000 And $10,000,000. Please Note That The 255 Calendar-day Period Of Performance For The Design Completion Begins With The Issuance Of The Noa And That A Notice To Proceed (ntp) Will Not Be Issued For The Completion Of A Design Project.
submission Requirements:
the Below Information Contains The Instructions And Format That Must Be Followed For The Submission Of The Sf 330 Statement Of Qualifications:
submit One (1) Sf 330 Statement Of Qualifications To Contract Specialist Rachel Heider At Nco20aesf330@va.gov And Rachel.heider@va.gov. This Must Include Parts I And Ii And Any Applicable Attachments.
the Submission Must Include The Sf 330, Architect-engineer Qualifications (form Is Available Online At Http://www.cfm.va.gov/contract/ae.asp).
the Sf 330 Submission Is Due By January 13, 2025 At 11:00 Am Pst.
the Sf 330 Must Be Submitted In One Email And Have A File Size No Larger Than 5 Mb. No Hard Copies Will Be Accepted.
the Subject Line Of The Email Must Read: Sf 330 Submission 36c26025r0032 Project 668-25-102 Replace Asphalt, Drywells, And Sidewalks.
the Sf 330 Submission Must Not Exceed A Total Of 35 Pages. This Includes Title Page, Table Of Contents, And Any Other Relevant Information. Any Pages Submitted By An Offeror That Exceed The Limit Will Not Be Considered During The Evaluation. Each Page Must Be In Arial Size 12 Font, Single Spaced. Part Ii Of The Sf 330 And Any Cpars Or Ppqs Will Not Count Toward The Page Limitation.
a Ppq Obtained For Another Sf 330 Submission May Be Submitted For This Project. However, If Significant Portions Of The Project Have Been Completed Since The Ppq Was Filled Out, A New Ppq Should Be Submitted To Accurately Assess The Project.
firms Must Include The Following Information In Section B Of The Sf 330 Submission:
sam Unique Entity Identifier
tax Id Number
cage Code
primary Point Of Contact S Email Address And Phone Number
all Questions Must Be Submitted To Rachel.heider@va.gov And Dennis.einarson@va.gov With The Subject Line Sf 330 Questions - 36c26025r0032 Project 668-25-102 Replace Asphalt, Drywells, And Sidewalks. The Cutoff For Question Submission Is 12/30/2024 At 11:00 Am Pst. Questions Will Be Answered Through Amendment To The Notice Posted To Contract Opportunities At Sam.gov.
this Procurement Is A 100% Set-aside For Sdvosb Concerns. Offers Received From Other Than Sdvosbs Will Not Be Considered. Offerors Must Be Certified As Sdvosbs By The U.s. Small Business Administration (sba) And Visible In The Veteran Small Business Certification (vetcert) Database (https://veterans.certify.sba.gov/) At The Time Of Sf 330 Submission, Written Response Submission, And Award. Failure To Be Certified In The Vetcert Database At These Times Will Result In The Offeror Being Deemed Ineligible For Award.
all Joint Ventures Must Be Sba Certified At The Time Of Sf 330 Submission, Written Response Submission, And Award And Must Submit Agreements That Comply With 13 Cfr 128.402 Prior To Contract Award.
all Prime Firms Must Meet The Naics Code Requirement Specified In This Notice. The Contracting Officer Will Verify The Naics Code In Vetcert. Failure To Meet The Naics Code Requirement May Result In The Rejection Of The Sf 330 Submission.
sf 330 Submissions Received After The Date And Time Specified Will Not Be Considered. Late Proposal Rules Per Far 15.208 Will Be Followed For Late Submittals.
firms Not Providing The Required Information May Not Be Evaluated. All Information Must Be Included In The Sf 330 Submission Package.
it Is The Offeror S Responsibility To Check The Contract Opportunities Website At Sam.gov For Any Revisions To This Announcement Prior To Submitting Their Sf 330.
a-e Selection Process
firms Who Timely Submit Sf 330s In Response To This Announcement, And In Accordance With Submission Requirements, Will Be Considered For Evaluation. The Selection Will Be Made As Follows:
sf 330s Will Be Evaluated In Accordance With The Primary Selection Criteria As Stated In This Notice. These Evaluations Will Determine The Most Highly Qualified Firms For This Particular Requirement.
in Accordance With Far 36.602-3(c), At Least Three Of The Most Highly Qualified Firms Will Then Be Notified Of The Government S Intent To Hold Discussions. Firms That Were Not Selected For Discussions Will Be Notified At This Time. In Accordance With Far 36.607(b), Any Requested Debriefings Of Successful And Unsuccessful Firms Will Be Held After Final Selection Has Taken Place And Will Be Conducted, To The Extent Practicable, In Accordance With 15.503, 15.506(b) Through (f), And 15.507(c). Note That 15.506(d)(2) Through (d)(5) Do Not Apply To Architect-engineer Contracts.
discussions Will Be Held With Top Three Firms In The Form Of Written Responses. The Firms Invited To Participate In Discussions Will Be Notified By Contract Specialist Or Contracting Officer By Email With Detailed Instructions That Will Include Questions Or Topics To Address.
following The Completion Of Discussions, The Firms Will Be Evaluated And Ranked Based On The Primary And (if Necessary) Secondary Selection Criteria. The Final Evaluation And Ranking Will Consider The Sf 330 Submission For Each Firm, As Well As Additional Information Obtained Via Discussions. The Highest Rated Firm Will Be Selected To Receive The Solicitation And Engage In Negotiations.
the Solicitation Will Be Issued To The Highest Rated Firm As A Request For Fee Proposal (rfp). All Sow Attachments And Site-specific Documentation Will Be Provided To The Highest Rated Firm With The Rfp. A Site Visit May Be Authorized During The Negotiation Process.
an Award Will Then Be Made As Long As The Negotiation Of Rates And Hours Leads To A Fair, Balanced, And Reasonable Determination Of The Final Contract Price. If Negotiations With The Highest Rated Firm Are Unsuccessful, The Firm Will Be Notified That Negotiations Have Been Terminated. Negotiations Will Then Be Initiated With The Next Highest Rated Firm, And So On Until Award Can Be Made Or This Announcement Is Cancelled.
primary Selection Criteria:
firms Responding To This Notice Will Be Evaluated And Ranked Using The Primary And Secondary Selection Criteria Listed Below. The Factors Are Listed In Descending Order Of Importance. The Evaluation Will Consider How Each Factor Is Addressed And How It Is Formatted To Coincide With The Selection Criteria.
selection Criteria 1, Professional Qualifications (sections C Through E): The Evaluation Will Consider The Professional Qualification Necessary For Satisfactory Performance Of Required Service. The Evaluation Shall Consider The Specific Experience (minimum Of Five Years) And Qualifications (i.e., Education, Training, Registration, Certifications, Overall Relevant Experience, And Longevity With The Firm As Full-time Employees) Of Personnel Proposed For Assignment To The Project, And Their Record Of Working Together As A Team When Evaluating Professional Qualifications. The Lead Designer In Each Discipline Must Be Registered But Does Not Have To Be Registered In The Particular State Where The Project Is Located. The A-e Shall Demonstrate They Are Able To Sign And Stamp Each Drawing By Individuals Licensed In Any State In The United States For The Key Positions Listed Below. Provide Professional License Numbers And/or Proof Of Licensure.
a Resume For Each Of These Key Positions Must Be Provided Via Section E Of The Sf330. Key Positions And Disciplines Required For This Project May Include Among Others:
architect
civil Engineer
cost Estimator
electrical Engineer
environmental Engineer
fire Protection Engineer
geotechnical Engineer
project Manager
quality Assurance
structural Engineer
offer Must Include The Following Statement Of Sdvosb Compliance On The Cover Page When Submitting The Personnel Proposed To Perform The Work Under This Requirement:
I [signatory Authority] ___________________, [company Or Joint Venture]
__________________, Certify That The Sdvosb Prime Contractor Will Not Pay More Than 50% Of The Amount Paid By The Government To The Prime For Contract Performance To Firms That Are Not Certified Sdvosbs By The Small Business Association S Veteran Small Business Certification (vetcert) In Compliance Of Va Acquisition Regulation (vaar) 852.219-75.
the Information Provided In Sections C Through E Of The Sf 330 Will Be Used To Evaluate This Evaluation Factor. Do Not Include This Information In Section H, Unless It Is Pertinent To Support The Information Listed In The Other Sections.
selection Criteria 2, Specialized Experience And Technical Competence (sections F, G, And H):
the Evaluation Will Consider Specialized Experience And Technical Competence In Design And Construction Period Services For Existing Site Corrections, Including Sidewalks, Drainage, And Parking. Provide Information For Example Projects Which Best Illustrate The Proposed Team S Experience And Competencies For This Contract. Submissions Shall Include Information Regarding Experience And Competence In:
experience At A Medical Center
repair Existing Conditions And Issues In The Renovated And New Construction Space
provide New Electrical, Lighting, Fire Protection, Site Repair Or Construction Of Parking Lots, Sidewalks, And Drainage, The New And Renovated Spaces.
phasing Of The New Construction And Renovation To Minimize Disruption To Hospital Operations: Must Remain Operational Throughout Construction.
other Specialized Experience Includes Experience In Critical Path Scheduling, Seismic Design, Construction Infection Control Protocols, Waste Reduction, Use Of Recovered Materials, And Sustainable Design Practices.
submissions Shall Include The Following Information For Example Projects:
project Title, Location And Detailed Narrative Describing The Scope Of Services Provided Including The Type Of Work Performed By The Offeror And Its Role In The Project I.e., Prime Contract, Teaming Partner, Or Subcontractor
project Owner, Owner S Point Of Contact Including Telephone Number And Email Address.
services & Deliverables Provided Under The Contract Or Task Order
period Of Performance, Including Start And Completion Dates
total Dollar Value Of The Project
contract Number Associated With The Project.
submissions Shall Include No More Than Five (5) And No Less Than Three (3) Recent And Relevant, Government And Private Experience, Example Projects, Similar In Size, Scope, Construction Features And Complexity, Which Clearly Illustrate Experience And Competencies Listed Above And In Other Portions Of This Solicitation.
Recent Is Defined As Services Provided In The Five (5) Years Prior To The Closing Date Of This Solicitation.
Relevant Is Defined As Projects, Within The United States, Its Territories, Or Possessions, Requiring Tasks Identified In This Solicitation.
Similar Complexity Is Considered Projects Of An Operational, Construction, Or Design Likeness To The Work Covered In This Solicitation.
at Least Three (3) Example Projects Must Have Construction Completed Or Construction Substantially (50%+) Complete.
submit Example Project Information In Section F Of The Sf 330.
section G Of The Sf 330 Will Be Used To Evaluate The Prior Experience Of The Prime Firm And Any Key Subcontractors Working Together On The Provided Example Projects.
the Evaluation Will Also Consider Narratives Addressing The Following Topics For The Offeror, And Key Consultants, In Section H Of The Sf 330:
the Management S Approach
the Coordination Of Disciplines And Subcontractors
quality Control Procedures, And
familiarity With Va Design Guides/manuals, Master Specifications, And Other Applicable Standards.
the Narratives Should Clearly Illustrate How Each Of The Topics Were Addressed. Re-stating Or Reiterating This List Or The Scope Of Work In Section H Will Not Be Sufficient.
narratives Submitted In Section H Of The 330, Shall Not Exceed One (1) Page In Length For The Offeror And Each Key Consultant. The Narrative Submissions Shall Not Exceed Ten (10) Pages Total For This Criterion.
selection Criteria 3, Capacity (section H)
the Evaluation Will Consider The Team S Plan And The Evaluation Will Consider The Firm S Ability To Meet The Schedule Of The Overall Project, As Well As The Available Capacity Of Key Disciplines To Perform The Work In The Required Time.
provide The Available Capacity Of Key Disciplines By Providing Current Project Workload, Inclusive Of All Projects Awarded During The Previous 12 Months And The Full Potential Value Of Any Current Indefinite Delivery Contracts.
offeror Shall Clearly State Their Available Capacity Presenting Workload Percentages For The Key Disciplines And/or Team Members. Also, The Offeror Must Provide The Completion Percentages And Expected Completion Date For Projects Awarded In The Previous 12 Months. The Information For This Factor Shall Be Provided In Section H Of The Sf 330. Please Ensure The Capacity Applies Toward The Team/personnel Provided In The Sf 330.
selection Criteria 4, Past Performance (section H)
the Evaluation Will Consider The Firm S Past Performance On Contracts With Government Agencies And Private Industry In Terms Of Cost Control, Quality Of Work, And Compliance With Performance Schedules.
past Performance Will Be Evaluated For All Projects Provided In Section F. The Contractor Performance Assessment Rating System (cpars) Database Will Be Reviewed To Evaluate The Projects That Have A Cpars Entry. Cpars Are Not Required To Be Submitted With The Sf330 Submission. The Contract Number For The Project Must Be Submitted With Each Project In Section F So Cpars Can Be Reviewed In The Database.
for Any Project That Does Not Have Cpars Data Available, A Past Performance Questionnaire (ppq) Is Required To Be Submitted With The Sf330. The Ppq Should Be Rated And Signed By The Evaluator. In The Event That A Firm Does Not Receive A Requested Complete Ppq From An Evaluator Prior To The Time For Submission, The Firm Shall Submit The Partially Completed Ppq With Section 1 And The Evaluator Information In Section 2 Completed. Ensure A Poc Is Listed With The Project Title/contract Number. The Va Will Make Reasonable Attempts To Contact The Poc Upon Submission For Ppq Completion.
evaluations May Also Include Additional Performance Related From The Firm, Customer Inquiries, Government Databases, Publicly Available Sources, And Additional Projects In Cpars. The Government Reserves The Right To Contact Any Poc Listed On A Cpars Report Or Ppq.
failure To Provide Requested Data, Accessible Points Of Contact, Or Valid Phone Numbers May Result In A Firm Being Considered Less Qualified. All Projects Provided In The Sf 330 Must Be Completed By The Office/branch/individual Team Member Performing The Work Under This Contract. The Information For This Factor Shall Be Provided In Section H Of The Sf 330.
for Ppqs, Please Utilize The Attached Ppq Document Only. Completed Ppqs Should Be Incorporated Into The Sf 330 Directly. Ppqs Should Not Be Submitted Separately To Nco20 Directly. Any Ppqs Will Not Be Counted Towards The Page Limitations For This Submission. However, Any Narratives Provided For Past Performance In Section H Shall Not Exceed Two (2) Pages In Length And Will Be Counted Toward The Total Submission Page Limit.
selection Criteria 5, Knowledge Of The Locality (section H),
the Evaluation Will Consider The Knowledge Of The Locality, Including Specific Knowledge Of Local Conditions Or Project Site Features, Such As Geological Features, Climatic Conditions, Working With And Local Construction Methods Or Local Laws And Regulations Of The Area Of Spokane, Wa. The Information For This Factor Shall Be Provided In Section H Of The Sf 330.
note That The Intent Of This Factor Is To Showcase A Firm S Understanding Of The Project Site And Locality, And Not Where The Firm Is Located, How Far Away The Firm/branch Office Is From The Site, And How They Would Travel To The Site. Information Related To The Firm S Location Shall Be Provided In Section H Under Secondary Selection Criterion Factor 1, Geographic Location. See Below.
selection Criteria 6, Experience In Construction Period Services, (section H)
the Evaluation Will Consider Experience In Construction Period Services (cps) Necessary For Performance Of This Contract. Submissions Shall Provide Information Which Clearly Illustrates Cps Experience In The Following:
solicitation Support Services
professional Field Inspections During The Construction Period, Both Scheduled And Emergent
coordination With Commissioning Requirements/commissioning Services
review Of Construction Submittals For Design Conformance, Variance, And Applicable Code/standard Compliance
support In Answering Requests For Information (rfi) During The Construction Period
support Of Construction Contract Changes To Include Drafting Statements Of Work And Cost Estimates
maintaining A Comprehensive Submittal Log Inclusive Of Material Data, Shop Drawings, Certifications, Etc.
providing Timely And Complete Responses To Requests For Information
providing Supporting Documentation (statements Of Work, Cost Estimates, Technical Reports, Etc.) For Construction Modifications
providing Record Drawing Documentation
process For Correcting Design Errors/omissions Identified During Construction
attendance At Pre-bid, Post-award, And Commissioning Kick Off Construction Project Conferences
providing Minutes Of Weekly Construction Meetings Throughout The Duration Of Construction
site Visits During Construction Both Scheduled And Emergent
ensuring Compliance With The Design Drawings And Specifications
preparation Of Site Visit Reports
generation Of Punch-list Reports
review Of Construction Project Modifications For Cost And Technical Acceptability
attendance And Participation During The Final Acceptance Inspection
preparation Of Record Drawings Of The Completed Construction Project Based On The Construction Contactor S As-built Drawings
maintenance Of Rfi Logs
attendance At Weekly Conference Calls
providing Minutes Of Meetings Between The Ae, Va, And Contractors
pre-final Inspection Site Visits
production Of As-built Documentation
the Information For This Factor Shall Be Provided In Section H Of The Sf 330.
secondary Selection Criterion*:
Geographic Location.
location Of The Firm, As Measured By The Driving Distance (miles) Between The Offeror S Principal Business Location And The Mann-grandstaff Vamc, 4815 N Assembly St, Spokane, Wa. Determination Of The Mileage Will Be Based On Google Maps. (https://www.google.com/maps/dir/).
*the Secondary Selection Criterion Is Used As A Tiebreaker, If Necessary, In Ranking The Most Highly Qualified Firms Following The Completion Of Discussions. The Secondary Selection Criterion Will Not Be Applied When Determining A Firm S Sf 330 Submission Highly Qualified Or Not Highly Qualified.
see Attached Document: 668-25-102 A-e Presolicitation Description.
see Attached Document: Ae Sow 668-25-102.
see Attached Document: 2020 Gao High Quality Project Estimate Characteristics.
see Attached Document: Bldg 12 As-built Arch-str.
see Attached Document: Bldg 12 As-built Mep.
see Attached Document: Site Repair Replace Areas Rev 1.
see Attached Document: Design Review Comment Form.
see Attached Document: Ppq 668-25-102.
Closing Soon13 Jan 2025
Tender AmountRefer Documents
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Civil And Construction...+2Others, Building Construction
United States
Details: Request For Sf 330
a/e Idiq At The Capt James A. Lovell Federal Health Care Center (fhcc)
3001 Green Bay Rd, North Chicago Il, 60064
36c25225q0122
introduction:
this Is A Request For Sf330s For A Single Award Firm-fixed Price, Indefinite Delivery/indefinite Quantity (id/iq) Contract For Mep-a/e Professional Services At The Fhcc Under Naics 541330 Necessary For The Design Of Various In-house And Nonrecurring Maintenance Construction Projects, (nrm), Scip (strategic Capital Investment Planning) And Station Level Construction Projects At This Medical Center That Are Multi-discipline Engineering In Nature And Primarily Focused On Mechanical, Electrical, And Plumbing Design And Fca (facility Condition Assessment), (i.e., Mechanical, Electrical, Architectural, Civil Structural, Computer Engineering Services, Etc.). Services To Include, But Are Not Limited To Conceptual Design, Design Programming, Preliminary Designs, Working Drawings And Specifications, Cost Estimating, Site Visits, Miscellaneous Reports, And Construction Period Services. All Work Will Be For The Capt James A Lovell Federal Health Care Center North Chicago, Illinois.
pursuant To Public Law 109-461, This Solicitation Is Set-aside For Service-disabled Veteran-owned Small Business (sdvosb) Firms. In Accordance With Vaar 819.7003(b), At The Time Of Submission Of Bid, The Bidder Must Represent That It Is A Sdvosb Concern, A Small Business Concern Under The Naics Code Assigned To The Acquisition, And Is Cve Verified For Eligibility In The Vip Database.
attention To Special Notice Of Vaar Clause 852.219-75 Va Notice Of Limitations On Subcontracting - Certificate Of Compliance For Services And Construction. Failure Of Offeror To Attest And Sign The Certificate Of Compliance Shall Render The Offeror's Sf330 Submission Technically Unacceptable Outright And The Offeror Shall Not Be Eligible For Award. (see Page 6 Below)
this Announcement Is Not A Request For Proposal. No Solicitation Package Will Be Issued Via Sam. A Request For Proposal Will Be Issued Directly To The Top-rated Firm For Which Negotiations Will Commence In Accordance With Far Part 36.606. The Anticipated A/e Design Services, To Be Awarded, Will Be Procured In Accordance With The Selection Of Architects And Engineers Act (public Law 92-582), Federal Acquisition Regulation Part 36.6.
mileage Restriction: This Procurement Is Restricted To Sdvosb Concerns Located Within A 400-mile Radius Of The Fhcc. The 400-mile Radius Restriction Will Be Verified By Using The Website Https://www.freemaptools.com/radius-around-point.htm And Verifying The Distance From The Firm S Primary Or Satellite Office Location.
period Of Performance: Five-year Ordering Period
contract Type: Firm-fixed-price Idiq
estimated Magnitude Of Construction: Individual Task Orders Will Be Established For A Minimum Of $2,000 And A Maximum Of $6,000,000.00.
contract Ceiling: $25,000,000.00
naics Code: 541330 - Engineering Services
size Standard: $26 Million
attention To Special Notice Proof Of Sam Registration. Offerors Are Required To Submit Proof Of Sam Registry With Their Sf330 Submission. Failure Of Offeror To Submit Proof Of Sam Registration Shall Render The Offeror's Sf330 Submission Technically Unacceptable Outright And The Offeror Shall Not Be Eligible For Award.
sam: In Accordance With Far 19.301-1, At The Time Of Sf330 Submission And Prior To Award Of Any Contract, The Offeror Must Represent To The Contracting Officer That It Is A Small Business Concern Under The North American Industry Classification System (naics) Code Assigned To The Acquisition. Additionally, All Eligible Firms Must Be Registered And Current In The System For Award Management (sam) Database To Be Evaluated And Eligible For Contract Award. If The Firm Is Not Registered In Sam, You May Register Online At Https://www.sam.gov.
the Following Factors Are Included In The Request For Sf 330s And Will Be Used To Evaluate Firms. The Factors Are Listed In Descending Order Of Importance, In Accordance With Far 36.602-1 And Vaam M836.602-1. The Evaluation Will Consider How Each Factor Is Addressed And How It Is Formatted To Coincide With The Selection Criteria.
primary Selection Criteria:
1. Specialized Experience And Technical Competence: Specialized Experience In Health Care Facility And Associated Grounds And Structures Design And Construction Period Services.
specialized Experience Includes Healthcare Facility Specific Code And Industry Standards Such As Nfpa 99, Ashrae 170, And Others Listed At Design & Construction Procedures (pg-18-3) Topic 01 Available At Cfm Til (https://www.cfm.va.gov/til/).
include Government And Private Experience Detailing Each Projects Size, Scope, And Complexity, And Experience With Project Phasing, And Infection Control Planning To Maintain Hospital Operations During Construction. Of Particular Importance Will Be Describing The Contributing Disciplines Of Your Firm, And Your Processes, And How Your Work Enabled Positive Outcomes For The Example Clients.
the Evaluation Will Consider The Management Approach, Coordination Of Disciplines And Consultants, Quality Control Procedures, Prior Experience Of The Prime Firm And Any Key Consultants Working Together On Relevant Projects, And Familiarity With Va Design Guides/manuals, Master Specifications, And Other Applicable Standards.
2. Professional Experience And Qualifications: Discipline Leads, And Senior Architects And Engineers Must Have Graduated From An Abet Accredited Program, Maintain Current Licensure, And Possess No Less Than Five Years Professional Experience In The Discipline Of Their Assigned Responsibility (i.e. Only Licensed Electrical Engineers Can Design Electrical Systems). Expect Resumes To Be Fact-checked. Submitting False Information Will Adversely Affect Scoring.
personnel Proposed For Assignment To This Contract Possess A Current Registered Architect Or Professional Engineer License By A Us State, The District Of Columbia, Or Us Territory. Provide Professional License Jurisdiction Of Issue And License Numbers And/or Proof Of Licensure.
include The Vertical Transportation Planning Expert Along With The Credentials Of His Or Her Employer As Described At Pg-18-3 Topic 18. All Studies And Designs Are To Be Provided By Independent, Experienced, And Qualified Consultant That Normally Performs Vertical Transportation Studies And Design As A Standard Part Of Their Services, As Prescribed At Pg-18-10 Elevator Design Manual. Clarification: There Is No Industry Certification Named Medical Transport Logistics Consultant. Provide The Prescribed Qualifications And Submission Of Same.
physical Security Consultant Lead Must Hold The Physical Security Professional (psp) Certification Page 3 Source Selection Sensitive Far 2.101 And 3.104 Issued By Asis International. Telecom Network Sme Responsible For Compliant Planning Must Hold A Current Bicsi Registered Communications Distribution Designer (rcdd) Certification. Review The Current Physical Security And Resiliency Design Manual For More Required Certifications And Their Applicability. Do Not Submit Alternative Certifications Or Other Documentation Other Than Those Prescribed, Issued By The Organizations Prescribed. There Is No Alternative Physical Security Specialist. Only Asis Psp. Absence Of Prescribed Certifications Is Nonresponsive.
cost Estimates Prepared By The (in-house) Design Professionals Developing The Work Are Preferred Over Contracted Estimating Services Who Only Add To The Cost And Duration Of Design Efforts.
evaluation Will Consider Truthful Information Regarding Education, Certifications, Training, Registration, Relevant Experience, And Longevity With The Firm.
offer Must Include The Following Statement Of Sdvosb Compliance When Submitting The Personnel Proposed To Perform The Work Under This Requirement:
I [signatory Authority]______________________, [company] __________________ Certify That The Team Proposed To Perform Under This Requirement Demonstrates The Capability Of 50% Sdvosb Performance In Compliance Of 48 Cfr 852.219-10.
3. Capacity To Accomplish The Work In The Required Time, Including Maintaining Project Schedules, Budgets, And Quality Compliance. Firm(s) Will Be Required And Expected To Have The Capacity To Simultaneously Manage And Staff Multiple Assignments Of Various Size, Scope, And Complexity.
evaluation Will Consider The Firm S Plan And Ability To Meet The Schedule Of The Overall Project, As Well As The Available Capacity Of Personnel In Key Disciplines. Provide The Available Capacity Of Required Disciplines By Providing Current Project Workload, Inclusive Of All Projects Awarded During The Previous 12 Months And The Full Potential Value Of Any Current Indefinite Delivery Contracts. Note That Responses To This Factor Almost Always Present The Same Result, Therefore Ae Firms Will Do Well To Describe How They Will Ensure Schedule, Budget, And Quality Compliance. Don T Provide Marketing Statements Or Academic Descriptions Of The Terms. Provide Your Actual Process And How It (uniquely) Benefits Clients. Include Examples Of These Successes Along With Contact Information.
4. Past Performance On Contracts With Government Agencies In Terms Of Cost Control, Schedule Adherence, And Quality Of Work. Include Complete, Unedited Cpars Reports Or Past Performance Questionnaires (ppqs) If Cpars Data Is Not Available For Example Projects (similar Past Engagements).
it Is Optimal For Submissions To Align The Parts Of This Submission. Example Projects Should Be Supported By Cpars For That Project, Submitted Staff And Consultant Team History In That Project, And More To Affect A Package Of Sorts. Submitting Team Members Who Didn T Contribute To Example Projects Only Results In More Questions And Little Benefit.
government Past Performance Information Systems May Be Accessed. Evaluating Past Performance And Experience May Include Information Provided By The Firm, Customer Inquiries, Government Databases, Publicly Available Sources, And Additional Projects In Cpars Or Ipps. Failure To Provide Requested Data, Accessible Points Of Contact With Valid Phone Numbers Will Result In Reduced Scores.
5. Knowledge Of The Locality, And Servicing Office Location: Specific Knowledge Of Local Conditions Or Project Site Features, Such As Geological Features, Climatic Conditions, Local Construction Methods, Market Conditions, Medical Center Structures, And Key Stakeholders. Project Experiences At This Location Are The Target Response, Not Nws Or Usgs Data. We Recommend Against Presenting Projects That Went Badly, Or Were Cancelled, Or Required To Be Redesigned By Others As Examples.
6. Inclusion Of Sdvosb, Vosb, And Then Small/disadvantaged Businesses.
secondary Selection Criteria:
7. Servicing Office Location: Staffed Offices Of The Submitting Firm Are The Target. Do Not Submit Virtual Offices, Offices Of Other Firms, Residences, Or Properties Currently For Sale. Preference Is Available Design Professional Staff Within 400 Miles, Or Four Hours Of Fair-weather Travel. Local Firms Tend To Have More Location-specific Knowledge, Which Offers Benefit To The Effort. Submitted Staff Listed At Local Offices Cannot Later Charge Airfare, Or Other Travel Costs Including Wages Beyond Four Hours. Firms Lacking A Regional Presence Aren T Disqualified, Only Scored Lower In This Factor Unless Their Submitted Information If Found To Be Untruthful.
8. Reputation And Standing Of The Firm And Its Principal Officials With Respect To Professional Conduct And Performance, General Management, And Cooperation With All Project Stakeholders. Factor Also Includes Consideration Of Past Improper Or Incomplete Architectural And Engineering Services. Submission Of Information About Office Locations, Staff, Past Experience, And Other Criteria Offers Evidence Against The Reputation Of The Firm.
please Note: The Ae Evaluation Board Must Be Provided With Complete And Accurate Information For All Evaluation Factors Above In Order To Rank Interested And Eligible Firms. Therefore, The Ae Firm Must Expand Upon, As It Deems Necessary, On Any Evaluation Factor Not Well Demonstrated Or Addressed With Part 1a To Part Ig And Part Ii Of The Sf330. The Ae Firm Shall Use Part Ih And/or Use Additional Sheets To Supplement/address All Evaluation Factors To Clearly Demonstrate Its Qualifications.
additionally, Keep In Mind The Submission Requirement Restrictions Outlined Below When Addressing Evaluation Factors.
selection Process: In Accordance With Far 36.6, Sf330s Will Be Evaluated By The Evaluation Board Using The Evaluation Factors Identified In This Announcement. After Sf330s Have Been Evaluated, Discussions/interviews Will Be Held With At Least Three Of The Most Highly Qualified Firms. After Discussions Conclude, The Evaluation Board Will Evaluate The Qualifications Of The Firms Using The Same Evaluation Factors, Taking Into Consideration Both The Sf330 Submission And Subsequent Discussions, To Select The Most Preferred Firm From The Firms Considered To Be The Most Highly Qualified. Negotiations Will Then Begin With The Most Preferred Firm.
submission Requirements: Interested And Eligible Firms Should Submit Their Current Sf330 As Follows:
1) One (1) Electronic Pdf Copy To Ricky.bond@va.gov And Stacy.hoover2@va.gov
a. Size Limitation Is 10mb;
the Sf330s Are Due On February 3, 2025 At 4:30 Pm (cst).
acceptable Electronic Formats (software) For Submission Of Sf330 Packages:
(a) Files Readable Using The Current Adobe Portable Document Format (pdf);
(b) Files In Adobe Pdf Files: When Scanning Documents Scanner Resolution Should Be Set To 200 Dots Per Inch, Or Greater.
(c) Sf330s Shall Be Provided On Standard Letter Size 8-1/2 By 11-inch Paper, Limited To A Maximum Of Seventy-five (75), Single-sided, Single-spaced, And Numbered Pages. If More Than Seventy-five (75) Single-sided Pages Are Submitted, All Pages After Seventy-five (75) Pages May Not Be Evaluated. The Font For Text Shall Be Times New Roman 12-point Or Larger.
(d) Please Note That We Can No Longer Accept .zip Files Due To Increasing Security Concerns.
the Sf330 Can Be Downloaded Through The Gsa Forms Library At: Http://www.gsa.gov/portal/forms/type/top, Type In Sf330 In The Find A Form Block And Click On Search.
no Fax Responses Will Be Accepted: Personal Visits For Discussing This Announcement Will Not Be Entertained Or Scheduled. Questions May Be Directed Only By E-mail To Ricky.bond@va.gov And Stacy.hoover2@va.gov. Va Primary Points Of Contact: Stacy Hoover, Nco 12 Contracting Officer, Stach.hoover2@va.gov.
vaar 852.219-75 Requirement
****complete This Letter & Include With Sf330****
contractor Letterhead
certification:
va Notice Of Limitations On Subcontracting Certificate Of Compliance For Services And Construction (jan 2023) (deviation)
(a) Pursuant Toâ 38 U.s.c. 8127(l)(2), The Offeror Certifies That
(1) If Awarded A Contract (seeâ far 2.101â definition), It Will Comply With The Limitations On Subcontracting Requirement As Provided In The Solicitation And The Resultant Contract, As Follows: [contracting Officer Check The Appropriate Box Below Based On The Predominant Naics Code Assigned To The Instant Acquisition As Set Forth Inâ far 19.102.]
(i) [x ]â services.â in The Case Of A Contract For Services (except Construction), The Contractor Will Not Pay More Than 50% Of The Amount Paid By The Government To It To Firms That Are Notâ certifiedâ sdvosbsâ listed In The Sba Certification Databaseâ as Set Forth Inâ 852.219-73â orâ certifiedâ vosbsâ listed In The Sba Certification Databaseâ as Set Forth Inâ 852.219-74. Any Work That A Similarly Situatedâ certified Sdvosb/vosbâ subcontractor Further Subcontracts Will Count Towards The 50% Subcontract Amount That Cannot Be Exceeded. Other Direct Costs May Be Excluded To The Extent They Are Not The Principal Purpose Of The Acquisition And Small Business Concerns Do Not Provide The Service As Set Forth In 13 Cfr 125.6.
(ii) []â general Construction.â in The Case Of A Contract For General Construction, The Contractor Will Not Pay More Than 85% Of The Amount Paid By The Government To It To Firms That Are Notâ certifiedâ sdvosbsâ listed In The Sba Certification Databaseâ as Set Forth Inâ 852.219-73â orâ certifiedâ vosbsâ listed In The Sba Certification Databaseâ as Set Forth Inâ 852.219-74. Any Work That A Similarly Situatedâ certified Sdbosb/vosbâ subcontractor Further Subcontracts Will Count Towards The 85% Subcontract Amount That Cannot Be Exceeded. Cost Of Materials Are Excluded And Not Considered To Be Subcontracted.
(iii) [ ] Special Trade Construction Contractors. In The Case Of A Contract For Special Trade Contractors, The Contractor Will Not Pay More Than 75% Of The Amount Paid By The Government To It To Firms That Are Notâ certifiedâ sdvosbsâ listed In The Sba Certification Databaseâ as Set Forth Inâ 852.219-73â orâ certifiedâ vosbsâ listed In The Sba Certification Databaseâ as Set Forth Inâ 852.219-74. Any Work That A Similarly Situatedâ certified Sdbosb/vosbâ subcontractor Further Subcontracts Will Count Towards The 75% Subcontract Amount That Cannot Be Exceeded. Cost Of Materials Are Excluded And Not Considered To Be Subcontracted.
(2) The Offeror Acknowledges That This Certification Concerns A Matter Within The Jurisdiction Of An Agency Of The United States. The Offeror Further Acknowledges That This Certification Is Subject To Title 18, United States Code, Section 1001, And, As Such, A False, Fictitious, Or Fraudulent Certification May Render The Offeror Subject To Criminal, Civil, Or Administrative Penalties, Including Prosecution.
(3) If Va Determines That An Sdvosb/vosb Awarded A Contract Pursuant To 38 U.s.c. 8127 Did Not Act In Good Faith, Such Sdvosb/vosb Shall Be Subject To Any Or All Of The Following:
(i) Referral To The Va Suspension And Debarment Committee;
(ii) A Fine Under Section 16(g)(1) Of The Small Business Act (15 U.s.c. 645(g)(1)); And
(iii) Prosecution For Violatingâ 18 U.s.c. 1001.
(b) The Offeror Represents And Understands That By Submission Of Its Offer And Award Of A Contract It May Be Required To Provide Copies Of Documents Or Records To Va That Va May Review To Determine Whether The Offeror Complied With The Limitations On Subcontracting Requirement Specified In The Contract. Contracting Officers May, At Their Discretion, Require The Contractor To Demonstrate Its Compliance With The Limitations On Subcontracting At Any Time During Performance And Upon Completion Of A Contract If The Information Regarding Such Compliance Is Not Already Available To The Contracting Officer. Evidence Of Compliance Includes, But Is Not Limited To, Invoices, Copies Of Subcontracts, Or A List Of The Value Of Tasks Performed.
(c) The Offeror Further Agrees To Cooperate Fully And Make Available Any Documents Or Records As May Be Required To Enable Va To Determine Compliance With The Limitations On Subcontracting Requirement. The Offeror Understands That Failure To Provide Documents As Requested By Va May Result In Remedial Action As The Government Deems Appropriate.
(d) Offeror Completed Certification/fill-in Required. The Formal Certification Must Be Completed, Signed And Returned With The Offeror S Bid, Quotation, Or Proposal. The Government Will Not Consider Offers For Award From Offerors That Do Not Provide The Certification, And All Such Responses Will Be Deemed Ineligible For Evaluation And Award.
certification:
i Hereby Certify That If Awarded The Contract, ____________________________________________ [insert Name Of Offeror] Will Comply With The Limitations On Subcontracting Specified In This Clause And In The Resultant Contract. I Further Certify That I Am Authorized To Execute This Certification On Behalf Of _______________________________________________________________[insert Name Of Offeror].
printed Name Of Signee: __________________________________
printed Title Of Signee: __________________________________
signature: __________________________________
date: __________________________________
company Name: __________________________________
address: __________________________________
__________________________________
Closing Date3 Feb 2025
Tender AmountRefer Documents
5961-5970 of 6047 active Tenders