PROVINCE OF SULTAN KUDARAT Tender
PROVINCE OF SULTAN KUDARAT Tender
Costs
Summary
Petct Scanner , Hospital / Medical Equipment ,province Of Sultan Kudarat
Description
Description Petct - 32 Slice Ct Configuration Specifications: 1. Compliance To Major Scope Of Work "major Scope Of Work Is Defined Below: To Supply, Delivery, Installation, Testing & Commissioning Of A High End Positron Emission Tomography/computed Tomography (petct) System" 2. Installation Experience Of Petct Systems Bidder Shall Provide The List On Number Of Installation Bases Across The Globe And Install Base In Asean Countries 3. Project Management Bidder Shall Provide Project End To End Work Flow In A Gantt Chart; Details From Project Kick Off Till Proposed “go Live” Bidder Shall Manage And Monitor The Communication Channels. I.e. Meeting Setup & Minutes For All Stakeholders’ Engagement And On-going Communication Throughout The Project. Bidder Shall Provide The Related New Floor Plan Of Petct Examination And Control Room And The Proposed Petct System. Bidder Shall Specify The Room Temperature And Humidity For The Examination Room And Equipment’s Technical Room. 4. Software + It/ Components + Database Installation, License Implementation Bidder Shall Provide Dicom Conformance Statement Arrange User Acceptance Test And Sign Off (including Integrated System Workflows) 5. Equipment Related Hardware And Software And Safety Features Application Latest Conventional Petct Scanner Offering With At Least 32 Ct Slice Capable Of A Whole Body Pet – Ct With Automatic And Accurate Image Fusion General Features The System Shall Have An Integrated Internal Laser Patient Positioning Light At Coronal, Sagital And Axial Positions For Both Pet And Ct Patient The System Provide Both Functional And Anatomical Information With High Image Quality With Ct Based Attenuation Correction The Pet System Shall Have Capability To Produce Images Using All Commercially Available Radiopharmaceutical Agents With Highest Throughput The System Shall Perform The Fast Acquisition And Reconstruction Of High Quality Images With Minimum Radiation Dose To The Patients And Operators. The Pet Imaging System Consists Of The Multi-detector Ring With 3d Acquisition And Reconstruction The System Shall Be Able To Perform Simultaneous Image Reconstruction During Image Acquisition The System Shall Provide Consistently High Resolution And High Quality Images. The System Shall Have Motion Management Options For Clinical Motion Challenges Of Pet And Ct Fusion. The System Shall Be Able To Perform Wide Range Of Advanced Cardiac And Oncological Applications, With Basic Tool Enabling 3d Metabolic Volume Measurements And Accurate Anatomical Localization Of Physiologic And Pathological Processes. The System Shall Be Capable Of Functioning As Ct Or Pet Independently. The System Shall Be Able To Perform Daily Qa To Ensure The High Quality Of Pet Scans "the Pet Scanner Should Be Onsite Upgradable To A Larger Axial Coverage By Adding Additional Pet Detectors For Faster Patient Scan As Future Investment Protection. Future Expansion And Upgradability For A Faster Workflow And More Patient Throughput. " Essential Compenents Pet Subsystem Ct Subsystem X-ray Subsystem Patient Table System Operator Console With Image Display & Management Pet Reconstruction Algorithms Ct Advanced Reconstruction Algorithms Motion Management Independent Review & Analysis Workstation Technical Specifications Pet Subsystem Patented Pet Detector Assembly Crystal Material: Non-hygroscopic Scintillator Material For Detecting 511kev Positrons In Co-incidence Number Of Detector Ring: At Least 20 Detector Rings Crystal Size : 6.3mmx6.3mm Or Smaller For Better Resolution Crystal Thickness : 25mm Or More For Higher Sensitivity Pet Detector Parameters Coincidence Window: 10 Nanoseconds Or Better Transaxial Fov : 70cm Or More Axial Fov : 15cm Or More Overlap Between Each Bed Method: 30% Overlap Or Lower On Step & Shot Pet Performance All Specification Must Comply With Latest Nema 2012 Standards Publication Performance Measurements, Without Altering Parameters. Qc Software To Measure These Parameters Must Be Available In The System. Trans Axial Resolution Fwhm @ 1cm <=5.5mm Fwhm @ 10cm <=5.5mm Axial Resolution Fwhm @ 1cm <=5.5mm Fwhm @ 10cm <=5.5 Mm Nema System Sensitivity At Least 8cps/kbq Or Higher The System Shall Be Equipped With Specialized Functionality And Protocols For The Following Clinical Applications Full Body Imaging. Step And Shot Acquisition Console Tool For Follow Up Scans Advanced Neuro Imaging Software With Fdg Normal Databases And If Possible Provide Other Normal Database Available For Other Radiopharmaceuticals Advanced Pet Analysis Software With Percist, Tlg And Segmentation Tools. Radiotherapy Virtual Simulation Application Should Be Provided And Segmentation Methods Should Be Available For Rt Planning In Rtss Format. System Should Be Capable Of Dynamic, Gated, List Mode, Static And Whole Body Acquistion For Different Clinical Applications Ct Subsystem Gantry System The System Shall Have An Integrated Internal Laser Patient Positioning Light At Coronal, Sagittal And Axial Positions For Both Pet And Ct Patient. Gantry Aperture : 70cm Or More The System Shall Be Capable Of Conventional And Helical Scanning For Full Body Imaging Ct Scan Display Field Of View : 50cm Or More Min. Rotation Speed (360 Degree) For All Application : 1sec Or Faster Helical Pitch Range And Increments And If Freely Selectable Maximum Scan Time : 100 Sec Or More Minimum Slice Thickness : 0.625 Mm Or Less Detector System Ct Detector Row : 24 Rows Or More No. Of Ct Slice Per Rotation : 32 Slice Or More Number Of Elements : 20,000 Or More Detector Coverage : 20mm Or More Ct Image Quality Phantom Low-contrast Detectability : ≤5mm @ 0.30% At 13.3 Mgy Ctdiw For Helical Head And Abdominal/body Phantoms :≤19.6 Mgy/100 Mas For Helical Head And ≤9.9mgy/100 Mas For Helicalbody Axial Noise Level : ≤0.35% At 29.3 Mgy Helical Noise Level : ≤0.35% At 28.5 Mgy Dose Reduction Techniques Shall Be Available Automated Ma Modulation During Scanning Automated Pediatric Dose Optimization Feature Ma Adjustment Depending On Patient Size High Power X-ray System Max. Power Output : 50 Kw Or More Max. Tube Anode Heat Storage Capacity : 6 Mhu Or Higher Max. Tube Current : 400ma Or Higher Max. Tube Voltage : 140kv Or Higher Small Focal Spot Size : 0.9 X 0.7 Per Iec 60336/2005 Large Focal Spot Size : 1.2 X 1.1 Per Iec 60336/2005 Patient Table System Single Patient Table, Horizontal As Well As Vertical Bed Movement Table Load Capacity: 225 Kg Or More Horizontal Scan Range : 200cm Or More System Shall Be Equipped With Emergency Stop Button For Manual Over-ride For Patient Safety. Operator Shall Be Able To Control Table Position From Acquisition Console Or With Button Controls On Either Side Of The Gantry. Operator Has The Option To Position Table And Do The Landmarking From The Console To Lessen Operator Radiation Exposure From Injected Patients The Flat Table Top Should Be Provided Petct Or Ct Rt Planning Applications Operator Console With Image Display & Management One Fully Integrated Pet And Ct Console Or Better System Shall Support Patient Scheduling And Data Entry, Exam Protocol Selection, Protocol Viewing And Editing, Scan Data Acquisition, Image Reconstruction, Image Display And Routine Analysis, Autofilm, Autostore, Autotransfer. A Wide Range Of Pre-defined Examination Protocols With Capability Of Parameters Editing Smooth And Automatic Proceed Of Multi-bed Scanning Real Time Display Of Total Count Rate Shall Be Available Advanced Image Processing Such As Multi Planar Reconstruction, Multi Planar Volume Rendering And Maximum Intensity Projection. Shall Provide A Reconstruction Tool Of Fully Convergent Iterative Reconstruction To Allow Extremely Low Dose And Higher Quantitative Accuracy Simultaneous Acquisition, Reconstruction, Display, Archival And Network Single And Multiple Image Display Display Of Cine Whole Body Projection Views And In Three Orthogonal Planes Real Time Monitoring On Contrast Enhancement System Console Peripherals Assigned To Application Software And Image Files Hard Disk Drive : Atleast 1tb Data Archiving : Usb, Cd & Dvd Or Equivalent Lcd Monitor : Two 17" Lcd Or Larger Monitor Shall Be Of Resolution 1280 X 1024 View, Analyze And Qc Integrated Pet/ct Data Pet Reconstruction Algorithms Routine Reconstruction Algorithm : Should Have High Definition And Latest Pet Reconstruction Technique To Improve The Snr Of Pet Images. Pet-detector Response Incorporating Psf As A Function Of Scanner Parameters To Provide Low Noise High Quality Pet Images In A Short Time After Acquisition, The Pet Reconstruction Algorithm Should Have Advanced Reconstruction Technique To Have Higher Snr: Full Convergence Iterative Reconstruction Technology Providing Up To 2 Times Improvement In Pet Quantitation Accuracy. 3d Reconstruction Technique Including: Random Events Correction Detector Normalization And Dead-time Correction Detector Geometry Modeling Attenuation Correction Using Ct Patient Data In The Whole 70cm Transverse Fov Iterative Volume Scatter Correction Based On Pet And Ct Data All The Correction Methods Should Be Included In The Reconstruction Iterative Loop. Ct Advanced Reconstruction Algorithm Statistical Iterative Reconstruction : Sinogram Space Ir Or Better Allows Further Reduction In Dose To Patients Compared To Conventional Method Motion Management Motion Management With Digital Respiratory Gating Simultaneous Multi-statics And Motion Acquisition For Pet Detection Enhancement Advanced List-mode Acquisition Allowing Simultaneous List Mode And Whole Body Multi-static, Dynamic And Gated Pet Acquisitions In Single Acquisition Latest Digital Deviceless Respiatory Gating Technology Should Be Provided To Perform The Respiratory Gating Application For All Patients. Independent Review & Analysis Workstation Computer Make And Model: Hp Z4 Workstation Or Higher Model Processor : Processor Intel® Xeon® E5 2600 V3, Equivalent Or Higher Operating System : Linux Os Ram Memory : 32gb Or More Hard Disk : Atleast 1tb Medical Grade High Resolution Color Dual Monitor: Monitor Resolution For Clinical Diagnostic Purposes Data Backup : Cd/dvd Or Equivalent Offline Dicom Dvd Burner The Workstations Shall Be Able To Work Off-line From Operator Console And/or Other Workstation(s). System Shall Have Mechanism To Auto Protect Itself From Virus And Other Malware Attack From The Network. User / Application Software Package Topogram Statistical Evaluation And Mpr Cine Display Image Annotation And Labeling Multi-modality Review, Comparison And Processing 3d Volume Rendering Analysis Fused Volume Rendering For Pet And Ct Navigator And Other Volumetric Visualization And Analysis Tools Image Registration For Multi-modality Fusion Software For Pet And Ct Fusion Software For Pet And Mr Automatic Image Reformatting, Storage And Filming Oncology Application Application Software Shall Be Licensed In All Workstations Oncology Software To Assist Clinicians In Diagnosis, Staging, Treatment Planning And Monitoring Treatment Response. Visualization And Analytical Monitoring Of Disease Progression Or Response To Treatment Or Therapy Using Multiple Exams Comparison. Automated Visualization And Highlights Of Abnormal And Suspicious Lesion For Pet Radiopharmaceutical Uptake Allows Measurement Of Suv And Volume For Any Pet Defined Metabolic Activity. Auto Define Metabolic Volume Suv Contouring. Select And Define Circular And Rectangular Roi. Shall Have Quantification Analysis For Both Recist And Percist Criteria Automatic Fetching Of Relevant Prior Studies For Multi-time Point Comparison. Display Of Analytical Information In A Tabular Format For Quick Comparison, Percent Change, Enables Structured Reporting, Allows Direct Interaction Between Multiple Exam Reviews. Neurology Application: Application Software Shall Be Licensed (permanent) Fully Automated Analysis Method Comparison With Normal Database Provides Review Of Pet Neuro Scans With A General Re-orientation Of The Scan Volume To Standard Neurological Orthogonal Views Along The Intercomissural Ac-pc Line Allows Statistical Mapping Of Regional Metabolic Reduction Comparison To Age-stratified Asymptomatic Normal Database(fdg And Amyloid) 6. Environmental Requirement Safety And Standard Certifications Approved By Fda And Passed Factory Approval Test The Performance Of The Unit Shall Conform To All National Radiation Protection Regulations In Force For Equipment Generating Ionizing Radiation. Certified By Iec Or Ieee Or Both 7. Other Components High Pressure Injector A High Pressure Dual Syringe Injector Compatible With The Petct System The System Shall Be Freely Movable And Have User Selectable Multiple Protocols. 8. Contrast Injection Can Be Synchronized With Scanning Accessories Head Holder Leg Support: Soft Patient Mattress: Velcro Patient Straps: Positioning Aids: Built-in 2 Way Intercom "9. Full Ups System To Support Petct Gantry And Console. Separate Ups Should Be Offered For The Workstation." Hot Lab Accessories: Survey Meter (1 Unit) Contamination Monitor ( 1 Unit) Dose Calibrator For Pet (1 Unit) Dose Calibrator Reference Sources (cs137, And Ba133) (1 Unit) Compact L-block With Dose Calibrator Shield (1 Unit) Lead Brick Cave, 3 Wall (1 Unit) Dose Drawing System, Pet (1 Unit) Syringe Shield 3cc (2 Units) Syringe Shield 5cc (2 Units) Syringe Carrier Large (2 Units) Mobile Radiation Shield (1 Unit) Personnel Dosimeter (2 Units) Decontamination Kit (1 Unit) Lead Gown (2 Units) Gloves Lead Lined (1 Unit) Forceps (1 Unit) Sharps Container (1 Pack/unit) Fume Hood (1 Unit) Waste Container, Shielded (1 Units)
Contact
Tender Id
6488d7e4-e0cf-34df-8a18-e8424db0769fTender No
10688488Tender Authority
PROVINCE OF SULTAN KUDARAT ViewPurchaser Address
-Website
http://notices.philgeps.gov.ph