- Home/
- Philippines/
- Philippine Heart Center/
- Overview
Philippine Heart Center Tender
Philippine Heart Center Tender
Costs
Summary
Itb No.028.24- 1 Unit Magnetic Resonance Imaging (mri) Scanner , Hospital / Medical Equipment ,philippine Heart Center
Description
Description Itb No.028.24- 1 Unit Magnetic Resonance Imaging (mri) Scanner 1 description Of Function Magnetic Resonance Imaging (mri) Scanner Is A Type Of Diagnostic Test That Can Create Detailed Images Of Nearly Every Structure And Organ Inside The Body With Capabilities For Cardiac, Vascular, Brain Head And Neck, Musculoskeletal And Body Imaging Including All Accessories And Peripherals Necessary For These Examination And For The Safety Of All Involved, As Well As The Necessary Capabilities For Storage And Transmittal Of Imaging Data To The Existing Pacs Of The Phc. 2 operational Requirements System Complete With All Accessories As Specified In The Technical Specifications Below. 3 technical Specifications 3.1 Magnet 3.1.1 Mri Scanner: Mr Scanner Design 2018 Or Newer 3.1.2 Field Strength: 1.5 Tesla 3.1.3 Frequency: 60 Mhz Or Higher 3.1.4 Magnet Dimension: 1.62x1.88x2.29 (lxwxh) 3.1.5 Bore Sizes: 70 Cm Or Larger 3.1.6 Magnet Weight (with Cryogen): 2,300 Kg 3.1.7 Minimum Floor Space Requirement: 3.4m X 5.6m 3.1.8 Maximum Fov: 50cm X 50cm X 50cm Or Lager 3.1.9 Homogeneity: ≤ 5ppm For 55cm X 55cm X 50cm 3.1.10 Type Of Shimming: Both Passive And Active Shimming (dynamic) 3.1.11 Patient Specific Shimming: 3d Volume Shim 3.1.12 First Order Shimming: 3x Linear 3.1.13 Magnet Shielding: Active Or Passive Shielding As Needed 3.1.14 External Interference Shielding: Yes 3.1.15 Type Of Cryogen: Liquid Helium 3.1.16 Cryogen Maximum Volume: Less Than 20 Liters Helium 3.1.17 Cryogen Refill: No Refill During The Lifespan Of The Equipment 3.1.18 Vent/ Quench Pipe Requirement: No 3.2 Gradient System 3.2.1 Gradient Type: Solid State 3.2.2 Cooling (coil & Amplifier): Direct Liquid Cooling 3.2.3max. Amplitude For Each Axis: 45 Mt/m 3.2.4 Max. Slew Rate For Each Axis: 200 T/m/s 3.2.5 Max. Fov With Max. Gradient Amplitude: 500 To 550 Mm 3.2.6 Duty Cycle: 100% 3.3 Resolution 3.3.1 Max. Fov: Up To 550 Mm 3.3.2 Min. Fov: 5 Mm 3.3.3 Max. Scan Matrix: 2048 3.3.4 Max. Recon Matrix: 2048 3.3.5 Max. Number Of Slices: 1024 3.3.6 Min. Slice Thickness (2d): 0.1 To 5 Mm 3.3.7 Max. Slice Thickness (2d): 250 To 320 Mm 3.3.8 Min. Slice/partition (3d): 0.05 Mm 3.3.9 Max. Slice/partition Thickness (3d): 64 Mm 3.3.10 Slab Thickness 3d (min): 5 Mm 3.3.11 Slab Thickness 3d (max): 500 Mm 3.4 Radiofrequency System 3.4.1 Rf Transmitter Power: 18kw Or Higher 3.4.2 Number Of Channels: Channel Independent System Or Up To 72 Channels 3.4.3 Signals Chain From Coil To Reconstruction: Fully Digital 3.5 Rf Coil 3.5.1 One (1) Pc Spine Coil: 44 Channels Minimum 3.5.2 One (1) Pc Head And Neck Coil: 20 Channels Minimum 3.5.3 One (1) Pc Body Coil For Abdomen, Pelvis, Cardiac And Prostate Examinations For Adult And Pediatric Patients : 32 Channels Minimum 3.5.4 One (1) Pc Flex Coil Medium: Channels: 6 Minimum 3.5.5 One (1) Pc Flex Coil Small: Channels: 4 Minimum 3.5.6 One (1) Pc Dedicated Knee Coil: Minimum# Of Channels: 16 3.5.7 One (1) Pc Dedicated Breast Coil: Minimum # Of Channels: 7 3.5.8 One (1) Pc Dedicated Shoulder Coil: Minimum # Of Channels: 16 3.6 Patient Table 3.6.1 Horizontal Travel Distance: 175cm Or More 3.6.2 Horizontal Travel Speed: Minimum Of 200 Mm/sec 3.6.3 Max. Weight Capacity: 250 Kg 3.6.4 Minimum Table Height: 59 Cm Or Lower 3.6.5 Iv Pole Integrated: Yes 3.6.6 Auto Sensing Coil Ports: Required 3.6.7 Emergency Switch For Quick Release Of Table Top 3.7 Console /host Computer System And Reconstructor 3.7.1 Processor: Manufacturers Standard 3.7.2 Ram/memory: Manufacturers Standard 3.7.3 System Disk: Manufacturers Standard 3.7.4 Image Database Disk: Manufacturers Standard 3.7.5 Parallel Scanning And Saving Images: Manufacturers Standard 3.7.6 Reconstruction Speed: Manufacturers Standard 3.7.7 Console Display Size: Manufacturers Standard 3.7.8 Resolution: Manufacturers Standard 3.7.9 Integrated Two-way Intercom System And Emergency Stop Button: Required 3.7.10 Cd/dvd Writer : Required 3.7.11 Keyboard And Optical Mouse : Required 3.7.12 Hard Drive Capacity: Manufacturers Standard 3.7.13 Ups: Manufacturers Standard 3.8 Connectivity 3.8.1 Pacs/ris Configuration: Required 3.8.2 Dicom Protocols: Required 3.8.3 Enhanced Multiframe Mr Dicom: Required 3.8.4 Dicom Mr Image Transfer 3.8.4.1 Dicom Workflow Management: Required 3.8.4.2 Dicom Modality Worklist: Required 3.8.4.3 Dicom Modality Performed Procedure Steps: Required 3.8.4.4 Dicom Storage Commitment: Required 3.8.5 Dicom Send/recieve: 3.8.5.1 Dicom Enhanced Mr: Required 3.8.5.2 Export/import Of Dicom Enhance Mr Image: Required 3.8.5.3 Export/import Of Dicom Mr Spectroscopy: Required 3.8.5.4 Export/import Of Dicom Raw: Required 3.8.6 Dicom Mr 3.8.6.1 Export/import Of Dicom Mr Images: Required 3.8.7 Dicom Sc 3.8.7.1 Export/import Of Sc (color) Image Data: Required 3.8.7.2 Dicom Query/retrieve: Required 3.8.8 Dicom Print 3.8.8.1 Grayscale Softcopy Presentation State With Preset Window Settings As On The Console: Required 3.8.8.2 Basic Grayscale Print: Required 3.8.8.3 Dicom Media: Required 3.8.8.4 Mr Studies On Dvd (read/white): Required 3.8.8.5 Ihe Integrated Profiles: Required 3.8.8.6 Schedule Workflow: Required 3.8.8.7 Patient Information Reconciliation: Reqiured 3.8.8.8 Consistent Presentation Of Images: Required 3.8.8.9 Basic Security: Required 3.8.9 Compatible With The Latest Dicom Version: Required 3.8.10 Unlimited Dicom License: Required 3.9 Software And Application 3.9.1 Software For Scanning, Processing And Parameter Editing: Required 3.9.2 Capability To Separate One Patient Folder Into Multiple Studies: Required 3.9.3 Parallel Imaging To Reduce Scan Time: Required 3.9.4 Signal Uniformity Correction: Required 3.9.5 Image Edge Enhancement And Smoothing: Required 3.9.6 High-resolution Acquisitions And Reconstruction (2048 Matrix): Required 3.9.7 Image-based Shimming Method: Required 3.9.8 Synthetic High B-value Dwi: Required 3.9.9 Software To Reduce B0-induced Distortions For Epi Sequence For Brain: Required 3.9.10 Automatic Correction Of Adc Variability For Reproducible Results: Required 3.9.11 Automatic Patient Coaching For Breathing Instructions, Table Movement And Scan Duration: Required 3.9.12 Noise Reduction Software: Required 3.9.13 Automatic Adjustment Of Scan Parameters For Patients With Mr Conditional Implant: Required 3.9.14 Ai Automated Planning For Brain: Required 3.9.15 Ai Automated Planning For Spine: Required 3.9.16 Al Automated Planning For Knee: Required 3.9.17 Al Automated Planning For Shoulder: Required 3.9.18 Metal Artifact Reduction In-plane And Through-plane: Required 3.9.19 Dixon Technique For Gradient Echo Sequences: Required 3.9.20 Whole Body Head-to-toe Imaging: Required 3.9.21 Motion Correction Software: Required 3.9.22 Free Breathing 3d T1 -weighted Imaging For Abdomen: Required 3.9.23 Dixon Technique For Tse/ Fse Sequences: Required 3.9.24 Swi Including Phase Maps: Required 3.9.25 Single And Multi-voxel Spectroscopy Application: Required 3.9.26 Black Blood Prepulse To Suppress Blood Signal: Required 3.9.27 3d Imaging For Spine: Required 3.9.28 3d Imaging For Brachial And Lumbar Plexus With Black Blood Prepulse: Required 3.9.29 Small Fov Dwi: Required 3.9.30 Dti / Fiber Tracking: Required 3.9.31 Cardiac Perfusion And T1 Scout Imaging: Required 3.9.32 T1, T2 And T2* Cardiac Mapping: Required 3.9.33 Non Contrast Coronary Imaging With Respiratory And Cardiac Gating: Required 3.9.34 Parallel Imaging Technique Employing Undersampling Time And Space, Suited For Dynamic And Real-time Cardiac Studies: Required 3.9.35 User Defined T1 Mapping Schemes As Alternative To Native Abd Contrast-enhanced Schemes: Required 3.10 Workstation 3.10.1 5 Sets Monitor For Image Review And Comparison: 27inch Medical Grade Dual Display With Unlimited License 3.10.2 Cpu: Manufacturers Standard 3.10.3 Cpu Memory/ram: Manufacturers Standard 3.10.4 Dicom Capable: Required 3.10.5 Perform Query / Retrieve: Required 3.10.6 Capable Of Mip / Mpr: Required 3.10.7 Neuro Image Processing Like Perfusion, Diffusion, Perfusion Diffusion Mismatch, Dti, Fibertracking, Spectroscopy, Bold: Required 3.10.8 Comprehensive Cardiac Image Processing Including Deep Learning Based Contour Detection: Required 3.10.8.1 Patient Data: Required 3.10.8.2 Series Overview: Required 3.10.8.3 Image Viewer: Required 3.10.8.4 Multimodality Viewer: Required 3.10.8.5 Lv & Rv Function With Lax & Sax: Required 3.10.8.6 2d Flow & Vascular: Required 3.10.8.7 Integrated Reporting Module: Required 3.10.8.8 Tissue Characterization: Required 3.10.8.9 T1 Mapping: Required 3.10.8.10 T2 Mapping: Required 3.10.8.11 Iron Quntification (t2* Mapping): Required 3.10.8.12 Semi-q Perfusion: Required 3.10.8.13 Coronary Imaging: Required 3.10.9 Vascular Image Processing: Required 3.10.1 Prostate Image Processing Including Lesion Segmentation: Required 3.10.11 Stitching/pasting For Spine, Whole Body, Lower Limb Angio Imaging: Required 3.10.12 Multi-parameteric Dynamic Image Processing: Required 3.10.13 Ups For Computer System: Manufacturers Standard 3.10.14 Hard Drive Capacity: Manufacturers Standard 3.11 Standard Pulse Sequences 3.11.1 Gradient Echo: Required 3.11.2 Fast/turbo Gradient Echo: Required 3.11.3 Spoiled Gradient Echo: Required 3.11.4 Dual Echo Fast Gradient Echo: Required 3.11.5 Spin Echo And Fast/turbo Spin Echo: Required 3.11.6 Fast/turbo Spin Echo (single Shot): Required 3.11.7 Fluid Attentuation Inversion Recovery (flair): Required 3.11.8 Echo Planar Imaging (epi): Required 3.11.9 Short T1 Inversion Recovery (stir): Required 3.11.10 Double Inversion Recovery (dir): Required 3.11.11 Triple Inversion Recovery (tir): Required 3.11.12 Fat Water Separation Imaging: Required 3.11.13 2d/3d Tof: Required 3.11.14 2d/3d Pc: Required 3.11.15 Mrcp/mr Urogram: Required 3.11.16 Fast Imaging Employing Steady-state Acquisition: Required 3.11.17 Automated Multi-station Run-off Acquisition: Required 3.11.18 3d Magnetization-prepared, Rapid Gradient-echo: Required 3.11.19 Advance And Latest Acceleration Techniques: Required 3.11.20 Neuro Imaging 3.11.20.1 3d Fse/ Tse Isotropic Imaging For Neuro: Required 3.11.20.2 3d Fse Double Inversion Recovery 3.11.20.3 Non-contrast Cerebral Perfusion Technique Based On Pulsed And Continuous Blood Labeling Technique: Required 3.11.20.4 Susceptibility Artifacts Reduction Diffusion Weighted Imaging: Required 3.11.20.5 Sequence To View Brachial Plexus: Required 3.11.20.6 Motion Correction, Kindly State The Contrast Available For Correction Sequences For Head, Neck, Spine, Axial, Sagittal And Coronal Orientations: Required 3.11.20.7 Fast Suppression With 4 Set Of Images- Inphase, Out Of Phase, Water Only & Fat Only: Required 3.11.20.8 Spectroscopy Single & Multi Voxel, 2d/3d Csi: Required 3.11.20.9 Tractography Or Fiber Tracking: Required 3.11.20.10 Perfusion Study: Required 3.11.20.11 Deep Learning Based Automatic Slice Placement For Various Brain Anatomies: Required 3.11.20.12 Simultaneous Multislice Scan For Diffusion/dti (fast Diffusion With Multiple Slice Acquisition In Single Scan) Based On Compressed Sensing Based: Required 3.11.20.13 Vessel Wall Imaging: Required 3.11.20.14 Tailored 3d Imaging: Required 3.11.20.15 Brain Volume Determination (ie Hippocampus-dementia Protocol): Required 3.11.21 Msk Imaging 3.11.21.1 Fat Suppression With 4 Set Of Images- Inphase, Out Of Phase, Water Only & Fat Only :required 3.11.21.2 Metal Artifact Reduction: Required 3.11.21.3 Metal Artifact Correction: Required 3.11.21.4 Cartilage T2 Assessment Technique With Color Maps: Required 3.11.21.5 3d Fse Isotropic Imaging: Required 3.11.21.6 Motion Correction Sequences For Msk With Axial, Sagittal And Coronal Orientations: Required 3.11.21.7 Compressed Sensing Based Acceleration Technique: Required 3.11.21.8 Tailored 3d Imaging: Required 3.11.21.9 Deep Learning Based Automatic Slice Placement: Required 3.11.21.10 Fracture Imaging: Required 3.11.22 Body Imaging 3.11.22.1 Fat Suppression With 4 Set Of Images- Inphase, Out Of Phase, Water Only & Fat Only :required 3.11.22.2 Liver Fat Quantification Techniques: Required 3.11.22.3 Liver T2 Sequence For Thalassemia/ Iron Quantification: Required 3.11.22.4 Free Breathing Feature Without Respiratory Belt: Required 3.11.22.5 3d Fse/ Tse Isotropic Imaging For Body Imaging: Required 3.11.22.6 Multiphasic Dynamic Liver Acquisition: Required 3.11.22.7 Free Breathing, High Temporal Resolution, Multiphase Dynamic Contrast Enhanced Imaging Using Stack Of Star Technique With Motion Compensation: Required 3.11.22.8 2d Single Shot Fse/tse: Required 3.11.22.9 Compressed Sensing Based Acceleration Technique For Body Imaging: Required 3.11.22.10 Synthetic Dwi Imaging Or Calculated Dwi: Required 3.11.22.11 4d Multiphase Dynamic Contrast Enhanced Imaging: Required 3.11.23 Vascular Imaging 3.11.23.1 Non-contrast 2d Mra (carotid, Popliteal, Femoral: Required 3.11.23.2 Non-contrast Substraction Mr Angio For Peripheral: Required 3.11.23.3 Non-contrast Angio For Renal: Required 3.11.23.4 Non-contrast Angio For Brain: Required 3.11.23.5 Time Resolved Dynamic Mra Angio Technique: Required 3.11.23.6 Bolus Chasing With Automatic Moving Table With Flouro Triggered Mr Angiography: Required 3.11.24 Breast Imaging 3.11.24.1 Bilateral Breast Imaging: Required 3.11.24.2 3d Fse/tse Isotropic Imaging For Breast: Required 3.11.24.3 4d Multiphase Dynamic Contrast Enhanced Imaging: Required 3.11.24.4 Fat Suppression With 4 Set Of Images-inphase, Out Of Phase, Water Only & Fat Only: Required 3.11.24.5 Dynamic T1: Required 3.11.24.6 Silicone Suppression Sequence: Required 3.11.25 Diffusion Imaging 3.11.25.1 Whole Body Diffusion Weighted Imaging: Required 3.11.25.2 Fse Based Diffusion To Reduce Susceptibility Artifacts: Required 3.11.25.3 Synthetic Or Calculated Diffusion To Offer Higher B Value Like 2000+: Required 3.11.25.4 Multi Shot Diffusion: Required 3.11.25.5 2d Selected Rf Excitation - High Resolution & Small Field Of View Diffusion For All Anatomies: Required 3.11.26 Cardiac Imaging 3.11.26.1 3d Heart Coverage For Coronary Artery Imaging Or Cardiac Chamber Imaging: Required 3.11.26.2 Black Blood Single Shot Fse: Required 3.11.26.3 Single-shot Myocardial Delayed Enhancement: Required 3.11.26.4 Phase Sensitive Myocardial Delayed Sequence: Required 3.11.26.5 Myocardial Delayed Enhancement: Required 3.11.26.6 Iron Quantification: Required 3.11.26.7 Phase Contrast Imaging: Required 3.11.26.8 Cine Ir/ti Scout: Required 3.11.26.9 Fiesta Cine/ Truefisp Cine: Required 3.11.26.10 Cardiac Perfusion: Required 3.11.26.11 Cardiac Mapping " T1 & T2: Required 3.11.26.12 Coronary Imaging: Required 3.11.27 Other Scan Parameters 3.11.27.1 Cardiac Trigger With Victor Gating Technology Including One Set Of Patient Lead Wires And One Fiber Optic Peripheral Gating Probe: Required 3.11.27.2 Respiratory Trigger / Gating / Compensation: Required 3.11.27.3 Phase Over Sampling, No Phase Wrap Or Equivalent: Required 3.12 Mri Cooling/chiller System 3.12.1 Appropriate Compatible Chiller: Auto-start / Resume Mechanism 3.12.2 Can Be Operated For 24 Hours/day With 2 Units Of Water Chiller, One Standard And Second For Backup: Required 3.12.3 One (1) Unit Uninterrupted Power Supply (ups): Required 3.13 Air-conditioning System 3.13.1 Two (2) Units Appropriate Air Conditioning System For The Magnet Room/ Scanning Room: Required 3.13.2 One (1) Unit Appropriate Air Conditioning System For The Equipment/ Technical Room: Required 3.13.3 One (1) Unit Appropriate Air Conditioning System For The Control Room: Required 3.13.4 One (1) Unit Appropriate Air Conditioning System For The Reading Room: Required 3.14 Mri Room Preparation 3.14.1 Rf Shielding For The Mr Room: Required 3.14.2 Appropriate Interior To Be Prepared For The Mri Scan Room: Required 3.14.3 Skylight To Be Provided: Required 3.14.4 Installation Of Air-conditioning Units: Required 3.14.5 Construction/ Renovation Of The Control Room: Required 3.14.6 Site Preparation: Required 4 system Configuration Accessories, Spares And Consumables Mr Compatible Accessories 4.1 One (1) Mr Compatible Patient Trolley 4.2 One (1) Flexible Patient Transfer Board 4.3 Music System For Patient 4.4 Disposable Ear Plugs (1000 Pcs) 4.5 Disposable Headset Covers (1000 Pcs) 4.6 Two (2) Mr Compatible Wheelchair 4.7 Two (2) Units Mr Compatible Cctv System For Patient Observation: 4.7.1 Resolution 4k High Resolution Cameras With Digital Zoom And The Ability To Identify People From Up To 80 Feet Away 4.7.2 Video Output Can Produce Higher Quality Videos Of 720p And 1080p 4.7.3 Night Vision Can Capture Color Images At 0.05 Lux Light Conditions And Support At Least 40m At 0 Lux Conditions 4.7.4 Lens Fixed 4mm,f1.2 Lens With A View Angle More Than 89% 4.7.5 Power Camera Should Support Dual Power Such As Poe And External At The Same Time 4.8 One (1) Unit Wall-mounted Mr Compatible Oxygen Monitor For Mr Room 4.9 One (1) Hand-held Metal Detector 4.10 Mri Compatible Dual Head Power Injector 4.11 One (1) Mr Compatible Fire Extinguisher 4.12 Security Straps & Positioning Aids 4.13 One (1) Mr Compatible Iv Stand 4.14 One (1) Secured Mr Coil Cabinet 4.15 Mr Compatible Patient Monitor Which Includes The Following Parameters: Bp, Ecg, Rr And Pulse Oximeter Monitoring Capabilities, Applicable For Adult, Children And Neonates. 4.16 Ten (10) Packs Mri Compatible Ecg Electrodes 4.17 One (1) Unit Laser Printer: 4.17.1 Technology Photothermographic (dry Laser) 4.17.2 Image Quality A. 325 Pixels Per Inch, 78 Inch Micron Laser Spot Spacing B. 14-bit Pixel Depth Architecture 4.17.3 Throughput Up To 40 Films Per Hour, 14x17 In. (35x43 Cm) 4.17.4 Laser Imaging Film A. Blue 7-mil Polyester Base B. Daylight-load Film Cartridges C. 125 Sheets/cartridge D. Printed Film Images With A Standard Dmax Of 3.0 4.18 Mri Compatible Anesthesia Machine : 4.18.1 Two Gases With Low Flow Cascade Tubes For All Gases 4.18.2 Two Position Selectatec Backbar 4.18.3 Sevoflurane Vaporizer 4.18.4 Mechanical Hypoxic Guard 4.18.5 Automatic Compliance And Fresh Gas Compensation To Maintain Accurate Tidal Volumes 4.18.6 Integrated Pneumatically Driven And Microprocessor Controlled Multifunction Ventilator With Colour Touch Screen 4.18.7 Gauss Alarm 4.18.8 Volume, Pressure, Spontaneous, Psv-plus, Pressure With Volume Guarantee,simv, Smmv, Cardiac Bypass 4.18.9 Four Available Waveforms 4.18.10 Minimum 5 Hours Battery Back Up 4.18.11 Variable Orifice Patient Proximal Spirometry 4.18.12 Co2 Absorber Has Ventilator And Bag Mode Switching, On/off Switch And Quick Release Canister 4.19 Five (5) Unit Headset 4.20 Fifty (50) Units Mr Compatible Ecg Leads And Cable For Cardiac Gating 4.21 One (1) Phantom Per Coil (total Of 8 Coils), One (1) Calibration Phantom With Holder, One (1) Acr Phantom With Holder 4.22 Mr Compatible Medicine Trolley 4.23 Mr Compatible Infusion Pump 4.24 Ups For All Imaging Processing Computers With Maintenance Free Batteries For Minimum 1 Hour Back Up 4.25 Wallmounted Mr Compatible Suction System 4.26 Thirty (30) Heavy Duty Clerical Chair: 4.26.1 Material Deluxe Fabric Seat And Backrest 4.26.2 Adjustability Adjustable Armrest, Seat Heights, Seat Depths, Back Heights, Recline Angles, Tilt Locks And Tension Control 4.26.3 Backrest Conform To The Natural Curvature Of The Spine And Provide Adequate Lumbar Support 4.26.4 Weight Capacity Up To 160 Kg Or More 4.26.5 Gas Cylinder Class 4 Gas Lift Can Support Loads Up To 250 Kg 4.26.6 Base Steel Or Nylon Base With Hooded Double Wheel Caster 4.27 Mr Compatible Infant Cradle 5 environmental Factors 5.1 The Unit Shall Be Capable Of Being Stored Continuously In Ambient Temperature Of 0-50deg C And Relative Humidity Of 15-90% 5.2 The Unit Shall Be Capable Of Operating In Ambient Temperature Of 20-30 Deg C And Relative Humidity Of Less Than 70% 5.3 Shall Meet Iec-60601-1-2 :2001(or Equivalent Bis) General Requirements Of Safety For Electromagnetic Compatibility Or Should Comply With 89/366/eec; Emc-directive. 6 power Supply 6.1 Power Input 440-480vac, 60hz Fitted With Phc Electrical Outlet 6.2 Resettable Over-current Breaker Shall Be Fitted For Protection 6.3 Suitable Ups With Maintenance Free Batteries For Minimum One Hour Backup Should Be Supplied With The System 6.4 Step-up And/or Step-down Power Transformer(s) If Required To Be Provided With Appropriate Ratings To Supply Power From The Main Electrical Source To The Mri Scanner. The Supplier Provides The Electrical Connection To The Hospital's Main Power Line.: Required 6.5 One (1) Unit Uninterrupted Power Supply (ups) For Mri Scanner 6.6 One (1) Transient Voltage Surge Suppressor (tvss) With Appropriate Ratings For The Mri Scanner Appropriate Wirings And Circuit Breakers For The Mri Scanner, Chiller And Equipment Room 7 standards, Safety And Training 7.1 Manufactures/supplier Should Have Iso 13485 Certificate To Quality Standard. 7.2 Should Be Ce Or Ul Or Bis Approved Product 7.3 Valid Certificate Of Medical Device Registration From Fda Philippines 7.4 Comprehensive Technical Training For Phc Biomed And User’s Training To Staff For Familiarity With The System. 7.5 Electrical Safety Conforms To Standards For Electrical Safety Iec 60601-1 General Requirements (or Equivalent International/national Standard) 7.6 Comprehensive Warranty On Parts And Service For The Mri System Including Helium And Chiller System: 5 Years 7.7 Preventive Maintenance Every Year: Quarterly For 5 Years 7.8 Regular Calibration Using Phantom: Quarterly For 5 Years 7.9 Warranty For Third Major Party Accessories. Pressure Injector, Patient Monitor, Ups, Chillers, Rf Shielding: 5 Years 7.10 24/7 Fast Response Time Customer Service/ Service Engineers (including Holidays And Weekends) 7.11 Mandatory Software Updates Until The Lifetime Of The Machine Free Of Charge 7.12 Two Weeks International Training Of 2 Radiologist And 2 Radiologic Technologist In A Reputable Training Institution 7.13 Two Weeks Follow-up On-site Training At Least Once A Year Distributed Throughout Warranty Period 8 documentation 8.1 User/technical/maintenance Manuals To Be Supplied In English. 8.2 Certificate Of Calibration And Inspection. 8.3 List Of Important Spare Parts And Accessories With Their Part Number And Costing. 8.4 List Of Equipments Available For Providing Calibration And Routine Maintenance Support As Per Manufacturer Documentation In Service / Technical Manual 8.5 Certification From The Manufacturer That The Model Offered Of The Mri System Is The Latest Model With At Least 2022 Onwards, Unused And Was Not Subjected To Product Recall Duly Notarized. 8.6 Certification From The Manufacturer That The Parts Of The Mri System Are Available For The Next 15 Years After Expiration Of The Warranty Period Duly Notarized. 8.7 Certification From The Manufacturer Duly Notarized That They Have A Local Engineers Trained To Conduct Preventive And Corrective Maintenance Of The Offered Model Mri System. 8.8 Certification From The Manufacturer That The Terms And Conditions Stated In The Contract Shall Be Honored By Them In The Event That A Change Of Exclusive Distributorship Will Occur During The Duration Of The Said Contract Duly Notarized.
Contact
Tender Id
4c5be076-4a81-32bb-beef-d559f1d3021dTender No
10708962Tender Authority
Philippine Heart Center ViewPurchaser Address
-Website
http://notices.ps-philgeps.gov.ph