Led Tenders

Led Tenders

VETERANS AFFAIRS, DEPARTMENT OF USA Tender

Others
United States
Details: Sources Sought Notice sources Sought: This Is Not A Solicitation For A Proposal, Proposal Abstract, Or Quote. The Purpose Of This Notice Is To Obtain Information Regarding Qualified Business Sources. The Responses To The Information Requested Will Assist The Government In Determining The Appropriate Acquisition Method. statement Of Work (sow) the Contractor Shall Render Genetic Testing Laboratory Services In Accordance With This Statement Of Work To Support The Health Science Research Department At Durham Va Medical Center Under The Direction Of Dr. Deepak Voora, Executive Director Of National Pharmacogenomics Program At Va Central Office, For The Study/iir Titled, Reducing Veterans' Risk Of Atherosclerotic Cardiovascular Disease Through Pharmacogenomics Informed Statin Prescribing Funded By The Va Durham Healthcare System And Delivered To The Indianapolis Va Health Care System. description: Genomic Medicine Research Has Many Complexities Requiring Specialized Services, Skills, And Expertise, Including Complex Laboratory Analyses Requiring Specialized Equipment And Expertise In The Generation And Interpretation Of Genomic Data; Large Complex Genomic Datasets With Particular Storage, Privacy, And Information Security Requirements; Clinical Expertise In How Genomic Medicine Interventions Might Inform Health Care And Impact Health Outcomes; And Sensitivity To The Ethical, Psychosocial, Legal, And Regulatory Considerations Of Genomic Medicine Research. background: This Research Grant Proposes A Single Center, Randomized Clinical Trial Of Precision Statin Prescribing Versus Usual Care To Be Conducted At The Indianapolis Va Health Care System. Four-hundred And Ten (410) Veteran Patients Who Are At Risk For Cardiovascular Events And Have A Class I Indication For Statin Therapy, But Are Not Currently Prescribed One, Will Be Recruited And Randomly Allocated To Receive Either 1) Genetic Test Report That Provides An Assessment Of Their Risk For Cardiovascular Disease Events Based On A Polygenic Risk Score (prs) For Coronary Artery Disease And Their Risk Of Statin Associated Musculoskeletal Symptoms Based On Slco1b1 Genetic Testing Or 2) Usual Care. Specimens For Genetic Testing Will Be Collected Via Saliva Kit Administered With The Assistance Of Research Staff And Shipped Using A Common Carrier Delivery Service And Standard Chain Of Custody. description Of Work: The Contractor S Laboratory Services Shall Be In Accordance With Clinical Laboratory Improvement Amendments (clia) And Be A College Of American Pathologists (cap) Certified Clinical Diagnostic Genetic Testing Laboratory In Order To Successfully Perform The Required Genetic Testing For This Study. the Performing Laboratory Will Perform Dna Testing For A Prs For Cad And Slco1b1 Based Dna Sequencing, Pcr, Or Array-based Technologies, Analysis, Interpretation, And Reporting For This Study. the Certification And Accreditation (c&a) Requirements Do Not Apply, And That A Security Accreditation Package Is Not Required. primary Contractor Duties Include, But Are Not Limited To: specimen Accessioning, Extraction, And Test Management dna Sequencing And/or Genotyping For polygenic Risk Score (prs) For Coronary Artery Disease Cad genome Wide Genotyping/sequencing whole Genome Imputation variant Calling sample Qc genetic Variant Qc ancestry Specific Prs Calculation For Cad prs Interpretation And Report In Pdf Format slco1b1 Genetic Testing genotyping/sequencing variant Calling sample/variant Qc Star Allele Diplotype And Phenotype Interpretation Based On The Clinical Pharmacogenetics Implementation Consortium (cpic) Guidelines. reporting In Pdf Format each Laboratory Tests Unit Shall Include: saliva Swab Dna Collection Kit genome-wide Genotyping With Illumina Iscan Microarray Technology whole Genome Imputation variant Calling sample Qc (call Rate, Nominal Coverage, Heterozygosity Rate) genetic Variant Qc (genotype Probability) ancestry Specific Prs Calculation For Cad Prs cad Prs Reporting In Pdf Format slco1b1 Testing And Reporting In Pdf Format deliverables: Specific Items To Be Delivered To The Va Investigators, Include, But Are Not Limited To: human Specimen Sample Collection Supplies And Shipping Materials, Compliant With All Current Federal Regulations. clinical Polygenic Risk Score And Slco1b1 Report For Participants Randomized To The Genetic Testing Arm Of The Study. a Required Total Of An Estimated 68 Tests Per Year For Three (3) Years. other Pertinent Information: the Contractor Shall Provide Services For Both Components Of Necessary Testing: 1. Polygenic Risk Score For Coronary Artery Disease And 2. Slco1b1 Genetic Testing. the Contractor Shall Provide An Existing Ldt That They Have Available For The Purposes In This Statement Of Work, As Va Does Not Have An Ldt For These Purposes. The Vendor Shall Have An Existing Ldt As The Va Will Use The Ldt Within One Month Of The Contract Being Awarded. the Contractor Shall Not Work In Conjunction With Another Laboratory For The Polygenic Risk Score Or The Genetic Testing For Slco1b1 As Subcontracting Out And Shipping Samples From One Contractor S Laboratory To Another Is Not Within Best Interest Of The Va S Need At This Time. the Contractor S Services Shall Be Available Readily To Render To Va, In House, At Time Of Contract Award. timeframe: The Estimated Beginning And Ending Dates During Which The Contractor Is Required To Perform Work For Va Durham Are 1/13/2025 To 1/12/2026 With The Option To Renew Yearly Through 1/13/2028. va Information And Information System Security And Privacy Language 1. General. This Entire Section Applies To All Acquisitions Requiring Any Information Security And Privacy Language. Contractors, Contractor Personnel, Subcontractors And Subcontractor Personnel Will Be Subject To The Same Federal Laws, Regulations, Standards, Va Directives And Handbooks, As Va Personnel Regarding Information And Information System Security And Privacy. 2. Va Information Custodial Language. This Entire Section Applies To All Acquisitions Requiring Any Information Security And Privacy Language. a. The Government Shall Receive Unlimited Rights To Data/intellectual Property First Produced And Delivered In The Performance Of This Contract Or Order (hereinafter Contract ) Unless Expressly Stated Otherwise In This Contract. This Includes All Rights To Source Code And All Documentation Created In Support Thereof. The Primary Clause Used To Define Government And Contractor Data Rights Is Far 52.227-14 Rights In Data General. The Primary Clause Used To Define Computer Software License (not Data/intellectual Property First Produced Under This Contractor Or Order) Is Far 52.227-19, Commercial Computer Software License. b. Information Made Available To The Contractor By Va For The Performance Or Administration Of This Contract Will Be Used Only For The Purposes Specified In The Service Agreement, Sow, Pws, Pd, And/or Contract. The Contractor Shall Not Use Va Information In Any Other Manner Without Prior Written Approval From A Va Contracting Officer (co). The Primary Clause Used To Define Government And Contractor Data Rights Is Far 52.227-14 Rights In Data General. c. Va Information Will Not Be Co-mingled With Any Other Data On The Contractor S Information Systems Or Media Storage Systems. The Contractor Shall Ensure Compliance With Federal And Va Requirements Related To Data Protection, Data Encryption, Physical Data Segregation, Logical Data Segregation, Classification Requirements And Media Sanitization. d. Va Reserves The Right To Conduct Scheduled Or Unscheduled Audits, Assessments, Or Investigations Of Contractor Information Technology (it) Resources To Ensure Information Security Is Compliant With Federal And Va Requirements. The Contractor Shall Provide All Necessary Access To Records (including Electronic And Documentary Materials Related To The Contracts And Subcontracts) And Support (including Access To Contractor And Subcontractor Staff Associated With The Contract) To Va, Va's Office Inspector General (oig), And/or Government Accountability Office (gao) Staff During Periodic Control Assessments, Audits, Or Investigations. e. The Contractor May Only Use Va Information Within The Terms Of The Contract And Applicable Federal Law, Regulations, And Va Policies. If New Federal Information Security Laws, Regulations Or Va Policies Become Applicable After Execution Of The Contract, The Parties Agree To Negotiate Contract Modification And Adjustment Necessary To Implement The New Laws, Regulations, And/or Policies. f. The Contractor Shall Not Make Copies Of Va Information Except As Specifically Authorized And Necessary To Perform The Terms Of The Contract. If Copies Are Made For Restoration Purposes, After The Restoration Is Complete, The Copies Shall Be Destroyed In Accordance With Va Directive 6500, Va Cybersecurity Program And Va Information Security Knowledge Service. g. If A Veterans Health Administration (vha) Contract Is Terminated For Default Or Cause With A Business Associate, The Related Local Business Associate Agreement (baa) Shall Also Be Terminated And Actions Taken In Accordance With Vha Directive 1605.05, Business Associate Agreements. If There Is An Executed National Baa Associated With The Contract, Va Will Determine What Actions Are Appropriate And Notify The Contactor. h. The Contractor Shall Store And Transmit Va Sensitive Information In An Encrypted Form, Using Va-approved Encryption Tools Which Are, At A Minimum, Federal Information Processing Standards (fips) 140-2, Security Requirements For Cryptographic Modules (or Its Successor) Validated And In Conformance With Va Information Security Knowledge Service Requirements. The Contractor Shall Transmit Va Sensitive Information Using Va Approved Transport Layer Security (tls) Configured With Fips Based Cipher Suites In Conformance With National Institute Of Standards And Technology (nist) 800-52, Guidelines For The Selection, Configuration And Use Of Transport Layer Security (tls) Implementations. the Contractor S Firewall And Web Services Security Controls, As Applicable, Shall Meet Or Exceed Va S Minimum Requirements. j. Except For Uses And Disclosures Of Va Information Authorized By This Contract For Performance Of The Contract, The Contractor May Use And Disclose Va Information Only In Two Situations: (i) In Response To A Qualifying Order Of A Court Of Competent Jurisdiction After Notification To Va Co (ii) With Written Approval From The Va Co. The Contractor Shall Refer All Requests For, Demands For Production Of Or Inquiries About, Va Information And Information Systems To The Va Co For Response. k. Notwithstanding The Provision Above, The Contractor Shall Not Release Va Records Protected By Title 38 U.s.c. § 5705, Confidentiality Of Medical Qualityassurance Records And/or Title 38 U.s.c. § 7332, Confidentiality Of Certain Medical Records Pertaining To Drug Addiction, Sickle Cell Anemia, Alcoholism Or Alcohol Abuse Or Infection With Human Immunodeficiency Virus (hiv). If The Contractor Is In Receipt Of A Court Order Or Other Requests For The Above Mentioned Information, The Contractor Shall Immediately Refer Such Court Order Or Other Requests To The Va Co For Response. l. Information Made Available To The Contractor By Va For The Performance Or Administration Of This Contract Or Information Developed By The Contractor In Performance Or Administration Of The Contract Will Be Protected And Secured In Accordance With Va Directive 6500 And Identity And Access Management (iam) Security Processes Specified In The Va Information Security Knowledge Service. m. Any Data Destruction Done On Behalf Of Va By A Contractor Shall Be Done In Accordance With National Archives And Records Administration (nara) Requirements As Outlined In Va Directive 6300, Records And Information Management, Va Handbook 6300.1, Records Management Procedures, And Applicable Va Records Control Schedules. n. The Contractor Shall Provide Its Plan For Destruction Of All Va Data In Its Possession According To Va Directive 6500 And Nist 800-88, Guidelines For Media Sanitization Prior To Termination Or Completion Of This Contract. If Directed By The Cor/co, The Contractor Shall Return All Federal Records To Va For Disposition. o. Any Media, Such As Paper, Magnetic Tape, Magnetic Disks, Solid State Devices Or Optical Discs That Is Used To Store, Process, Or Access Va Information That Cannot Be Destroyed Shall Be Returned To Va.the Contractor Shall Hold The Appropriate Material Until Otherwise Directed By The Contracting Officer S Representative (cor) Or Co. Items Shall Be Returned Securely Via Va-approved Methods. Va Sensitive Information Must Be Transmitted Utilizing Va-approved Encryption Tools Which Are Validated Under Fips 140-2 (or Its Successor) And Nist 800-52. If Mailed, The Contractor Shall Send Via A Trackable Method (usps, Ups, Fedex, Etc.) And Immediately Provide The Cor/co With The Tracking Information. Self-certification By The Contractor That The Data Destruction Requirements Above Have Been Met Shall Be Sent To The Cor/co Within 30 Business Days Of Termination Of The Contract. p. All Electronic Storage Media (hard Drives, Optical Disks, Cds, Back-up Tapes, Etc.) Used To Store, Process Or Access Va Information Will Not Be Returned To The Contractor At The End Of Lease, Loan, Or Trade-in. Exceptions To This Paragraph Will Only Be Granted With The Written Approval Of The Va Co. 3. Access To Va Information And Va Information Systems. This Section Applies When Any Person Requires Access To Information Made Available To The Contractor By Va For The Performance Or Administration Of This Contract Or Information Developed By The Contractor In Performance Or Administration Of The Contract. a. A Contractor/subcontractor Shall Request Logical (technical) Or Physical Access To Va Information And Va Information Systems For Their Employees And Subcontractors Only To The Extent Necessary To Perform The Services Specified In The Solicitation Or Contract. This Includes Indirect Entities, Both Affiliate Of Contractor/subcontractor And Agent Of Contractor/subcontractor. b. Contractors And Subcontractors Shall Sign The Va Information Security Rule Of Behavior (rob) Before Access Is Provided To Va Information And Information Systems (see Section 4, Training, Below). The Rob Contains The Minimum User Compliance Requirements And Does Not Supersede Any Policies Of Va Facilities Or Other Agency Components Which Provide Higher Levels Of Protection To Va S Information Or Information Systems. Users Who Require Privileged Access Shall Complete The Va Elevated Privilege Access Request Processes Before Privileged Access Is Granted. c. All Contractors And Subcontractors Working With Va Information Are Subject To The Same Security Investigative And Clearance Requirements As Those Of Va Appointees Or Employees Who Have Access To The Same Types Of Information. The Level And Process Of Background Security Investigations For Contractors Shall Be In Accordance With Va Directive And Handbook 0710, Personnel Suitability And Security Program. The Office Of Human Resources And Administration/operations, Security And Preparedness (hra/osp) Is Responsible For These Policies And Procedures. Contract Personnel Who Require Access To Classified Information Or Information Systems Shall Have An Appropriate Security Clearance. Verification Of A Security Clearance Shall Be Processed Through The Special Security Officer Located In Hra/osp. Contractors Shall Conform To All Requirements Stated In The National Industrial Security Program Operating Manual (nispom). d. All Contractors And Subcontractors Shall Comply With Conditions Specified In Vaar 852.204-71(d); Contractor Operations Required To Be In United States. All Contractors And Subcontractors Working With Va Information Must Be Permanently Located Within A Jurisdiction Subject To The Law Of The United States Or Its Territories To The Maximum Extent Feasible. If Services Are Proposed To Be Performed Abroad The Contractor Must State Where All Non-u.s. Services Are Provided. The Contractor Shall Deliver To Va A Detailed Plan Specifically Addressing Communications, Personnel Control, Data Protection And Potential Legal Issues. The Plan Shall Be Approved By The Cor/co In Writing Prior To Access Being Granted. e. The Contractor Shall Notify The Cor/co In Writing Immediately (no Later Than 24 Hours) After Personnel Separation Or Occurrence Of Other Causes. Causes May Include The Following: (1) Contractor/subcontractor Personnel No Longer Has A Need For Access To Va Information Or Va Information Systems. (2) Contractor/subcontractor Personnel Are Terminated, Suspended, Or Otherwise Has Their Work On A Va Project Discontinued For Any Reason. (3) Contractor Believes Their Own Personnel Or Subcontractor Personnel May Pose A Threat To Their Company S Working Environment Or To Any Companyowned Property. This Includes Contractor-owned Assets, Buildings, Confidential Data, Customers, Employees, Networks, Systems, Trade Secrets And/or Va Data. (4) Any Previously Undisclosed Changes To Contractor/subcontractor Background History Are Brought To Light, Including But Not Limited To Changes To Background Investigation Or Employee Record. (5) Contractor/subcontractor Personnel Have Their Authorization To Work In The United States Revoked. (6) Agreement By Which Contractor Provides Products And Services To Va Has Either Been Fulfilled Or Terminated, Such That Va Can Cut Off Electronic And/or Physical Access For Contractor Personnel. f. In Such Cases Of Contract Fulfillment, Termination, Or Other Causes; The Contractor Shall Take The Necessary Measures To Immediately Revoke Access To Va Network, Property, Information, And Information Systems (logical And Physical) By Contractor/subcontractor Personnel. These Measures Include (but Are Not Limited To): Removing And Then Securing Personal Identity Verification (piv) Badges And Piv Interoperable (piv-i) Access Badges, Va-issued Photo Badges, Credentials For Va Facilities And Devices, Va-issued Laptops, And Authentication Tokens. Contractors Shall Notify The Appropriate Va Cor/co Immediately To Initiate Access Removal. g. Contractors/subcontractors Who No Longer Require Va Accesses Will Return Vaissued Property To Va. This Property Includes (but Is Not Limited To): Documents, Electronic Equipment, Keys, And Parking Passes. Piv And Piv-i Access Badges Shall Be Returned To The Nearest Va Piv Badge Issuance Office. Once They Have Had Access To Va Information, Information Systems, Networks And Va Property In Their Possessions Removed, Contractors Shall Notify The Appropriate Va Cor/co. 4. Training. This Entire Section Applies To All Acquisitions Which Include Section 3. a. All Contractors And Subcontractors Requiring Access To Va Information And Va Information Systems Shall Successfully Complete The Following Before Being Granted Access To Va Information And Its Systems: (1) Va Privacy And Information Security Awareness And Rules Of Behavior Course (talent Management System (tms) #10176) Initially And Annually Thereafter. (2) Sign And Acknowledge (electronically Through Tms #10176) Understanding Of And Responsibilities For Compliance With The Organizational Rules Of Behavior, Relating To Access To Va Information And Information Systems Initially And Annually Thereafter; And (3) Successfully Complete Any Additional Cyber Security Or Privacy Training, As required For Va Personnel With Equivalent Information System Or Information Access [to Be Defined By The Va Program Official And Provided To The Va Co For Inclusion In The Solicitation Document I.e., Any Rolebased Information Security Training]. b. The Contractor Shall Provide To The Cor/co A Copy Of The Training Certificates And Certification Of Signing The Organizational Rules Of Behavior For Each Applicable Employee Within Five Days Of The Initiation Of The Contract And Annually Thereafter, As Required. c. Failure To Complete The Mandatory Annual Training Is Grounds For Suspension Or Termination Of All Physical Or Electronic Access Privileges And Removal From Work On The Contract Until Such Time As The Required Training Is Complete. 5. Security Incident Investigation. This Entire Section Applies To All Acquisitions Requiring Any Information Security And Privacy Language. a. The Contractor, Subcontractor, Their Employees, Or Business Associates Shall Immediately (within One Hour) Report Suspected Security / Privacy Incidents To The Va Oit S Enterprise Service Desk (esd) By Calling (855) 673-4357 (tty: 711). The Esd Is Oit S 24/7/365 Single Point Of Contact For It-related Issues. After Reporting To The Esd, The Contractor, Subcontractor, Their Employees, Or Business Associates Shall, Within One Hour, Provide The Cor/co The Incident Number Received From The Esd. b. To The Extent Known By The Contractor/subcontractor, The Contractor/ Subcontractor's Notice To Va Shall Identify The Information Involved And The Circumstances Surrounding The Incident, Including The Following: (1) The Date And Time (or Approximation Of) The Security Incident Occurred. (2) The Names Of Individuals Involved (when Applicable). (3) The Physical And Logical (if Applicable) Location Of The Incident. (4) Why The Security Incident Took Place (i.e., Catalyst For The Failure). (5) The Amount Of Data Belonging To Va Believed To Have Been Compromised. (6) The Remediation Measures The Contractor Is Taking To Ensure No Future Incidents Of A Similar Nature. c. After The Contractor Has Provided The Initial Detailed Incident Summary To Va, They Will Continue To Provide Written Updates On Any New And Relevant Circumstances Or Facts They Discover. The Contractor, Subcontractor, And Their Employes Shall Fully Cooperate With Va Or Third-party Entity Performing An Independent Risk Analysis On Behalf Of Va. Failure To Cooperate May Be Deemed A Material Breach And Grounds For Contract Termination. d. Va It Contractors Shall Follow Va Handbook 6500, Risk Management Framework For Va Information Systems Va Information Security Program, And Va Information Security Knowledge Service Guidance For Implementing An Incident Response Plan Or Integrating With An Existing Va Implementation. e. In Instances Of Theft Or Break-in Or Other Criminal Activity, The Contractor/subcontractor Must Concurrently Report The Incident To The Appropriate Law Enforcement Entity (or Entities) Of Jurisdiction, Including The Va Oig, And The Va Office Of Security And Law Enforcement. The Contractor, Its Employees, And Its Subcontractors And Their Employees Shall Cooperate With Va And Any Law Enforcement Authority Responsible For The Investigation And Prosecution Of Any Possible Criminal Law Violation(s) Associated With Any Incident. The Contractor/subcontractor Shall Cooperate With Va In Any Civil Litigation To Recover Va Information, Obtain Monetary Or Other Compensation From A Third Party For Damages Arising From Any Incident, Or Obtain Injunctive Relief Against Any Third Party Arising From, Or Related To, The Incident. f. The Contractor Shall Comply With Va Handbook 6500.2, Management Of Breaches Involving Sensitive Personal Information, Which Establishes The Breach Management Policies And Assigns Responsibilities For The Oversight, Management And Reporting Procedures Associated With Managing Of Breaches. g. With Respect To Unsecured Protected Health Information (phi), The Contractor Is Deemed To Have Discovered A Data Breach When The Contractor Knew Or Should Have Known Of Breach Of Such Information. When A Business Associate Is Part Of Vha Contract, Notification To The Covered Entity (vha) Shall Be Made In Accordance With The Executed Baa. h. If The Contractor Or Any Of Its Agents Fails To Protect Va Sensitive Personal Information Or Otherwise Engages In Conduct Which Results In A Data Breach Involving Any Va Sensitive Personal Information The Contractor/subcontractor Processes Or Maintains Under The Contract; The Contractor Shall Pay Liquidated Damages To The Va As Set Forth In Clause 852.211-76, Liquidated Damages Reimbursement For Data Breach Costs 6. Information System Design And Development. This Entire Section Applies To Information Systems, Systems, Major Applications, Minor Applications, Enclaves, And Platform Information Technologies (to Include The Subcomponents Of Each) Designed Or Developed For Or On Behalf Of Va By Any Non-va Entity. a. Information Systems Designed Or Developed On Behalf Of Va At Non-va Facilities Shall Comply With All Applicable Federal Law, Regulations, And Va Policies. This Includes Standards For The Protection Of Electronic Protected Health Information (phi), Outlined In 45 C.f.r. Part 164, Subpart C And Information And System Security Categorization Level Designations In Accordance With Fips 199, Standards For Security Categorization Of Federal Information And Information Systems And Fips 200, Minimum Security Requirements For Federal Information Systems. Baseline Security Controls Shall Be Implemented Commensurate With The Fips 199 System Security Categorization (reference Va Handbook 6500 And Va Trusted Internet Connections (tic) Architecture). b. Contracted New Developments Require Creation, Testing, Evaluation, And Authorization In Compliance With Va Assessment And Authorization (a&a) Processes In Va Handbook 6500 And Va Information Security Knowledge Service To Obtain An Authority To Operate (ato). Va Directive 6517, Risk Management Framework For Cloud Computing Services, Provides The Security And Privacy Requirements For Cloud Environments. c. Va It Contractors, Subcontractors And Third-party Service Providers Shall Address And/or Integrate Applicable Va Handbook 6500, Va Handbook 6517, Risk Management Framework For Cloud Computing Services And Information Security Knowledge Service Specifications In Delivered It Systems/solutions, Products And/or Services. If Systems/solutions, Products And/or Services Do Not Directly Match Va Security Requirements, The Contractor Shall Work Though The Cor/co To Identify The Va Organization Responsible For Governance Or Resolution. Contractors Shall Comply With Far 39.1, Specifically The Prohibitions Referenced. d. The Contractor (including Producers And Resellers) Shall Comply With Office Of Management And Budget (omb) M-22-18 And M-23-16 When Using Third-party Software On Va Information Systems Or Otherwise Affecting The Va Information. This Includes New Software Purchases And Software Renewals For Software Developed Or Modified By Major Version Change After The Issuance Date Of M22-18 (september 14, 2022). The Term Software Includes Firmware, Operating Systems, Applications And Application Services (e.g., Cloud-based Software), As Well As Products Containing Software. The Contractor Shall Provide A Self Attestation That Secure Software Development Practices Are Utilized As Outlined By Executive Order (eo)14028 And Nist Guidance. A Third-party Assessment Provided By Either A Certified Federal Risk And Authorization Management Program (fedramp) Third Party Assessor Organization (3pao) Or One Approved By The Agency Will Be Acceptable In Lieu Of A Software Producer's Self Attestation. e. The Contractor Shall Ensure All Delivered Applications, Systems And Information Systems Are Compliant With Homeland Security Presidential Directive (hspd) 12 And Va Identity And Access Management (iam) Enterprise Identity Management Requirements As Set Forth In Omb M-19-17, M-05-24, Fips 201-3, Personal Identity Verification (piv) Of Federal Employees And Contractors (or Its Successor), M-21-31 And Supporting Nist Guidance. This Applies To Commercial Off-the-shelf (cots) Product(s) That The Contractor Did Not Develop, All Software Configurations And All Customizations. f. The Contractor Shall Ensure All Contractor Delivered Applications And Systems Provide User Authentication Services Compliant With Va Handbook 6500, Va Information Security Knowledge Service, Iam Enterprise Requirements And Nist 800-63, Digital Identity Guidelines, For Direct, Assertion-based Authentication And/or Trust-based Authentication, As Determined By The Design And Integration Patterns. Direct Authentication At A Minimum Must Include Public Key Infrastructure (pki) Based Authentication Supportive Of Piv And/or Common Access Card (cac), As Determined By The Business Need And Compliance With Va Information Security Knowledge Service Specifications. g. The Contractor Shall Use Va Authorized Technical Security Baseline Configurations And Certify To The Cor That Applications Are Fully Functional And Operate Correctly As Intended On Systems In Compliance With Va Baselines Prior To Acceptance Or Connection Into An Authorized Va Computing Environment. If The Defense Information Systems Agency (disa) Has Created A Security Technical Implementation Guide (stig) For The Technology, The Contractor May Configure To Comply With That Stig. If Va Determines A New Or Updated Va Configuration Baseline Needs To Be Created, The Contractor Shall Provide Required Technical Support To Develop The Configuration Settings. Far 39.1 Requires The Population Of Operating Systems And Applications Includes All Listed On The Nist National Checklist Program Checklist Repository. h. The Standard Installation, Operation, Maintenance, Updating And Patching Of Software Shall Not Alter The Configuration Settings From Va Approved Baseline Configuration. Software Developed For Va Must Be Compatible With Va Enterprise Installer Services And Install To The Default Program Files Directory With Silently Install And Uninstall. The Contractor Shall Perform Testing Of All Updates And Patching Prior To Implementation On Va Systems. i. Applications Designed For Normal End Users Will Run In The Standard User Context Without Elevated System Administration Privileges. j. The Contractor-delivered Solutions Shall Reside On Va Approved Operating Systems. Exceptions To This Will Only Be Granted With The Written Approval Of The Cor/co. k. The Contractor Shall Design, Develop, And Implement Security And Privacy Controls In Accordance With The Provisions Of Va Security System Development Life Cycle Outlined In Nist 800-37, Risk Management Framework For Information Systems And Organizations: A System Life Cycle Approach For Security And Privacy, Va Directive And Handbook 6500, And Va Handbook 6517. l. The Contractor Shall Comply With The Privacy Act Of1974 (the Act), Far 52.224-2 Privacy Act, And Va Rules And Regulations Issued Under The Act In The Design, Development, Or Operation Of Any System Of Records On Individuals To Accomplish A Va Function. m. The Contractor Shall Ensure The Security Of All Procured Or Developed Information Systems, Systems, Major Applications, Minor Applications, Enclaves And Platform Information Technologies, Including Their Subcomponents (hereinafter Referred To As Information Systems ) Throughout The Life Of This Contract And Any Extension, Warranty, Or Maintenance Periods. This Includes Security Configurations, Workarounds, Patches, Hotfixes, Upgrades, Replacements And Any Physical Components Which May Be Necessary To Remediate All Security Vulnerabilities Published Or Known To The Contractor Anywhere In The Information Systems (including Systems, Operating Systems, Products, Hardware, Software, Applications And Firmware). The Contractor Shall Ensure Security Fixes Do Not Negatively Impact The Information Systems. n. When The Contractor Is Responsible For Operations Or Maintenance Of The Systems, The Contractor Shall Apply The Security Fixes Within The Timeframe Specified By The Associated Controls On The Va Information Security Knowledge Service. When Security Fixes Involve Installing Third Party Patches (such As Microsoft Os Patches Or Adobe Acrobat), The Contractor Shall Provide Written Notice To The Va Cor/co That The Patch Has Been Validated As To Not Affecting The Systems Within 10 Business Days. 7. Information System Hosting, Operation, Maintenance Or Use. this Entire Section Applies To Information Systems, Systems, Major Applications, Minor Applications, Enclaves, And Platform Information Technologies (cloud And Noncloud) Hosted, Operated, Maintained, Or Used On Behalf Of Va At Non-va Facilities. a. The Contractor Shall Comply With All Federal Laws, Regulations, And Va Policies For Information Systems (cloud And Non-cloud) That Are Hosted, Operated, Maintained, Or Used On Behalf Of Va At Non-va Facilities. Security Controls For Collecting, Processing, Transmitting, And Storing Of Va Sensitive Information, Must Be In Place. The Controls Will Be Tested By Va Or A Va Sanctioned 3paoand Approved By Va Prior To Hosting, Operation, Maintenance Or Use Of The Information System Or Systems By Or On Behalf Of Va. This Includes Conducting Compliance Risk Assessments, Security Architecture Analysis, Routine Vulnerability Scanning, System Patching, Change Management Procedures And The Completion Of An Acceptable Contingency Plan For Each System. The Contractor S Security Control Procedures Shall Be The Same As Procedures Used To Secure Va-operated Information Systems. b. Outsourcing (contractor Facility, Equipment, Or Staff) Of Systems Or Network Operations, Telecommunications Services Or Other Managed Services Require Assessment And Authorization (a&a) Of The Contractor S Systems In Accordance With Va Handbook 6500 As Specified In Va Information Security Knowledge Service. Major Changes To The A&a Package May Require Reviewing And Updating All The Documentation Associated With The Change. The Contractor S Cloud Computing Systems Shall Comply With Fedramp And Va Directive 6517 Requirements. c. The Contractor Shall Return All Electronic Storage Media (hard Drives, Optical Disks, Cds, Back-up Tapes, Etc.) On Non-va Leased Or Non-va Owned It Equipment Used To Store, Process Or Access Va Information To Va In Accordance With A&a Package Requirements. This Applies When The Contract Is Terminated Or Completed And Prior To Disposal Of Media. The Contractor Shall Provide Its Plan For Destruction Of All Va Data In Its Possession According To Va Information Security Knowledge Service Requirements And Nist 800-88. The Contractor Shall Send A Self-certification That The Data Destruction Requirements Above Have Been Met To The Cor/co Within 30 Business Days Of Termination Of The Contract. d. All External Internet Connections To Va Network Involving Va Information Must Be In Accordance With Va Trusted Internet Connection (tic) Reference Architecture And Va Directive And Handbook 6513, Secure External Connections And Reviewed And Approved By Va Prior To Implementation. Government-owned Contractor-operated Systems, Third Party Or Business Partner Networks Require A Memorandum Of Understanding (mou) And Interconnection Security Agreements (isa). e. Contractor Procedures Shall Be Subject To Periodic, Announced, Or Unannounced Assessments By Va Officials, The Oig Or A 3pao. The Physical Security Aspects Associated With Contractor Activities Are Also Subject To Such Assessments. The Contractor Shall Report, In Writing, Any Deficiencies Noted During The Above Assessment To The Va Cor/co. The Contractor Shall Use Va S Defined Processes To Document Planned Remedial Actions That Address Identified Deficiencies In Information Security Policies, Procedures, And Practices. The Contractor Shall Correct Security Deficiencies Within The Timeframes Specified In The Va Information Security Knowledge Service. f. All Major Information System Changes Which Occur In The Production Environment Shall Be Reviewed By The Va To Determine The Impact On Privacy And Security Of The System. Based On The Review Results, Updates To The Authority To Operate (ato) Documentation And Parameters May Be Required To Remain In Compliance With Va Handbook 6500 And Va Information Security Knowledge Service Requirements. g. The Contractor Shall Conduct An Annual Privacy And Security Self-assessment On All Information Systems And Outsourced Services As Required. Copies Of The Assessment Shall Be Provided To The Cor/co. The Va/government Reserves The Right To Conduct Assessment Using Government Personnel Or A Third-party If Deemed Necessary. The Contractor Shall Correct Or Mitigate Any Weaknesses Discovered During The Assessment. h. Va Prohibits The Installation And Use Of Personally Owned Or Contractor-owned Equipment Or Software On Va Information Systems. If Non-va Owned Equipment Must Be Used To Fulfill The Requirements Of A Contract, It Must Be Stated In The Service Agreement, Sow, Pws, Pd Or Contract. All Security Controls Required For Government Furnished Equipment Must Be Utilized In Va Approved Other Equipment (oe). Configuration Changes To The Contractor Oe, Must Be Funded By The Owner Of The Equipment. All Remote Systems Must Use A Va-approved Antivirus Software And A Personal (host-based Or Enclave Based) Firewall With A Va-approved Configuration. The Contractor Shall Ensure Software On Oe Is Kept Current With All Critical Updates And Patches. Owners Of Approved Oe Are Responsible For Providing And Maintaining The Anti-virus Software And The Firewall On The Non-va Owned Oe. Approved Contractor Oe Will Be Subject To Technical Inspection At Any Time. i. The Contractor Shall Notify The Cor/co Within One Hour Of Disclosure Or Successful Exploits Of Any Vulnerability Which Can Compromise The Confidentiality, Integrity, Or Availability Of The Information Systems. The System Or Effected Component(s) Need(s) To Be Isolated From The Network. A Forensic Analysis Needs To Be Conducted Jointly With Va. Such Issues Will Be Remediated As Quickly As Practicable, But In No Event Longer Than The Timeframe Specified By Va Information Security Knowledge Service. If Sensitive Personal Information Is Compromised Reference Va Handbook 6500.2 And Section 5, Security Incident Investigation. j. For Cases Wherein The Contractor Discovers Material Defects Or Vulnerabilities Impacting Products And Services They Provide To Va, The Contractor Shall Develop And Implement Policies And Procedures For Disclosure To Va, As Well As Remediation. The Contractor Shall, Within 30 Business Days Of Discovery, Document A Summary Of These Vulnerabilities Or Defects. The Documentation Will Include A Description Of The Potential Impact Of Each Vulnerability And Material Defect, Compensating Security Controls, Mitigations, Recommended Corrective Actions, Fbonotice Cause Analysis And/or Workarounds (i.e., Monitoring). Should There Exist Any Backdoors In The Products Or Services They Provide To Va (referring To Methods For Bypassing Computer Authentication), The Contractor Shall Provide the Va Co/co Written Assurance They Have Permanently Remediated These Backdoors. k. All Other Vulnerabilities, Including Those Discovered Through Routine Scans Or Other Assessments, Will Be Remediated Based On Risk, In Accordance With The Remediation Timelines Specified By The Va Information Security Knowledge Service And/or The Applicable Timeframe Mandated By Cybersecurity & Infrastructure Security Agency (cisa) Binding Operational Directive (bod) 22-01 And Bod 19-02 For Internet-accessible Systems. Exceptions To This Paragraph Will Only Be Granted With The Approval Of The Cor/co. 8. Security And Privacy Controls Compliance Testing, Assessment and Auditing. This Entire Section Applies Whenever Section 6 Or 7 Is Included. a. Should Va Request It, The Contractor Shall Provide A Copy Of Their (corporation S, Sole Proprietorship S, Partnership S, Limited Liability Company (llc), Or Other Business Structure Entity S) Policies, Procedures, Evidence And Independent Report Summaries Related To Specified Cybersecurity Frameworks (international Organization For Standardization (iso), Nist Cybersecurity Framework (csf), Etc.). Va Or Its Third-party/partner Designee (if Applicable) Are Further Entitled To Perform Their Own Audits And Security/penetration Tests Of The Contractor S It Or Systems And Controls, To Ascertain Whether The Contractor Is Complying With The Information Security, Network Or System Requirements Mandated In The Agreement Between Va And The Contractor. b. Any Audits Or Tests Of The Contractor Or Third-party Designees/partner Va Elects To Carry Out Will Commence Within 30 Business Days Of Va Notification. Such Audits, Tests And Assessments May Include The Following: (a): Security/penetration Tests Which Both Sides Agree Will Not Unduly Impact Contractor Operations; (b): Interviews With Pertinent Stakeholders And Practitioners; (c): Document Review; And (d): Technical Inspections Of Networks And Systems The Contractor Uses To Destroy, Maintain, Receive, Retain, Or Use Va Information. c. As Part Of These Audits, Tests And Assessments, The Contractor Shall Provide All Information Requested By Va. This Information Includes, But Is Not Limited To, The Following: Equipment Lists, Network Or Infrastructure Diagrams, Relevant Policy Documents, System Logs Or Details On Information Systems Accessing, Transporting, Or Processing Va Data. d. The Contractor And At Its Own Expense, Shall Comply With Any Recommendations Resulting From Va Audits, Inspections And Tests. Va Further Retains The Right To View Any Related Security Reports The Contractor Has Generated As Part Of Its Own Security Assessment. The Contractor Shall Also Notify Va Of The Existence Of Any Such Security Reports Or Other Related Assessments, Upon Completion And Validation. e. Va Appointed Auditors Or Other Government Agency Partners May Be Granted Access To Such Documentation On A Need-to-know Basis And Coordinated Through The Cor/co. The Contractor Shall Comply With Recommendations Which Result From These Regulatory Assessments On The Part Of Va Regulators And Associated Government Agency Partners. 9. Product Integrity, Authenticity, Provenance, Anti-counterfeit And Anti-tampering. This Entire Section Applies When The Acquisition Involves Any Product (application, Hardware, Or Software) Or When Section 6 Or 7 Is Included. a. The Contractor Shall Comply With Code Of Federal Regulations (cfr) Title 15 Part 7, Securing The Information And Communications Technology And Services (icts) Supply Chain , Which Prohibits Icts Transactions From Foreign Adversaries. Icts Transactions Are Defined As Any Acquisition, Importation, Transfer, Installation, Dealing In Or Use Of Any Information And Communications Technology Or Service, Including Ongoing Activities, Such As Managed Services, Data Transmission, Software Updates, Repairs Or The Platforming Or Data Hosting Of Applications For Consumer Download. b. When Contracting Terms Require The Contractor To Procure Equipment, The Contractor Shall Purchase Or Acquire The Equipment From An Original Equipment Manufacturer (oem) Or An Authorized Reseller Of The Oem. The Contractor Shall Attest That Equipment Procured From An Oem Or Authorized Reseller Or Distributor Are Authentic. If Procurement Is Unavailable From An Oem Or Authorized Reseller, The Contractor Shall Submit In Writing, Details Of The Circumstances Prohibiting This From Happening And Procure A Product Waiver From The Va Cor/co. c. All Contractors Shall Establish, Implement, And Provide Documentation For Risk Management Practices For Supply Chain Delivery Of Hardware, Software (to Include Patches) And Firmware Provided Under This Agreement. Documentation Will Include Chain Of Custody Practices, Inventory Management Program, Information Protection Practices, Integrity Management Program For Sub-supplier Provided Components, And Replacement Parts Requests. The Contractor Shall Make Spare Parts Available. All Contractor(s) Shall Specify How Digital Delivery For Procured Products, Including Patches, Will Be Validated And Monitored To Ensure Consistent Delivery. The Contractor Shall Apply Encryption Technology To Protect Procured Products Throughout The Delivery Process. d. If A Contractor Provides Software Or Patches To Va, The Contractor Shall Publish Or Provide A Hash Conforming To The Fips Security Requirements For Cryptographic Modules (fips 140-2 Or Successor). e. The Contractor Shall Provide A Software Bill Of Materials (sbom) For Procured (to Include Licensed Products) And Consist Of A List Of Components And Associated Metadata Which Make Up The Product. Sboms Must Be Generated In One Of The Data Formats Defined In The National Telecommunications And Information Administration (ntia) Report The Minimum Elements For A Software Bill Of Materials (sbom). f. Contractors Shall Use Or Arrange For The Use Of Trusted Channels To Ship Procured Products, Such As U.s. Registered Mail And/or Tamper-evident Packaging For Physical Deliveries. g. Throughout The Delivery Process, The Contractor Shall Demonstrate A Capability For Detecting Unauthorized Access (tampering). h. The Contractor Shall Demonstrate Chain-of-custody Documentation For Procured Products And Require Tamper-evident Packaging For The Delivery Of This Hardware. summary: this Is A Sources Sought Notice And Not A Request For Quotes. This Request Is Solely For The Purpose Of Conducting Market Research To Enhance Vha S Understanding Of The Market S Offered Products, Services, And Capabilities. The Government Will Not Pay Any Costs For Responses Submitted In Response To This Sources Sought. this Sources Sought Notice Provides An Opportunity For Respondents To Submit Their Notice Of Ability, And Their Available Products And Services In Response To The Requirement. Vendors Are Being Invited To Submit Information Relative To Their Potential Of Fulfilling This Requirement In The Form Of A Capability Response That Addresses The Specific Requirement Identified In This Sources Sought. this Sources Sought Is To Facilitate The Contracting Officer S Review Of The Market Base, For Acquisition Planning, Size Determination, And Procurement Strategy. response Commitment: i. Response: all Potential Sources Are Invited To Submit, In Writing, A Capability Statement With Sufficient Information To Substantiate Your Business Is Reasonably Capable Of Performing The Work. The Capability Statement Must Clearly Demonstrate A Business S Ability To Fulfill The Requirement. The Burden Of Proof Rests With The Contractor; Therefore, Written Responses Must Provide Clear And Unambiguous Evidence To Substantiate Capabilities Appropriate To Satisfy This Need. a. Capability Statement With General Understanding Of The Industry And Current Knowledge And Subcontract Networks That Would Be Used To Support The Requirement As Identified Herein. Subcontractors Will Need The Security Requirements Listed In This Sources Sought. Submittals Furnished Will Not Be Returned To The Sender. No Debriefs Will Be Conducted. Eligibility In Participating In A Future Acquisition Does Not Depend Upon A Response To This Notice. responses Shall Provide Administrative Information, And Shall Include The Following As A Minimum: Company Name, Sam Uei Number, Company Mailing Address, Phone Number, Fax Number, Name And Title Of Designated Point Of Contact And E-mail Of Designated Point Of Contact. company Business Size And Status (i.e., Large Business, Small Business, Service-disabled Veteran Owned Small Business, Women-owned Small Business, Etc.), The Number Of Years In Business. b. Proprietary Information Is Neither Requested Nor Desired. If Such Information Is Submitted, It Must Clearly Be Marked "proprietary" On Every Sheet Containing Such Information, And The Proprietary Information Must Be Segregated To The Maximum Extent Practicable From Other Portions Of The Response (e.g., Use An Attachment Or Exhibit). submit Responses Email Only To Karly.gabrysiak@va.gov ii. Timeline: a. This Request Will Close On 01/06/2025 At 8am Est. notes: 1. This Sources Sought Is For Planning Purposes Only, And Does Not Constitute A Commitment, Implied Or Otherwise, That A Procurement Action Will Follow. The Department Of Veterans Affairs Will Use The Information Submitted In Response To This Notice At Its Discretion And Will Not Provide Comments To Any Submission; However, The Department Of Veterans Affairs Reserves The Right To Contact Any Respondent To This Notice For The Sole Purpose Of Enhancing The Department Of Veteran Affairs Understanding Of The Notice Submission. 2. The Content Of Any Responses To This Notice May Be Reflected In Any Subsequent Solicitation, Except For Content Marked Or Designated As Business Confidential Or Proprietary Which Will Be Fully Protected From Release Outside The Government. the Department Of Veteran Affairs Contracting Office Point Of Contact: name: Karly Gabrysiak title: Contract Specialist e-mail Address: Karly.gabrysiak@va.gov
Closing Date6 Jan 2025
Tender AmountRefer Documents 

The City Government Of Baguio Tender

Others...+1Electrical and Electronics
Philippines
Details: Description Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 1 1 Lot Various Materials For Smart City Command Center 15,500,000.00 22 Unit 16 Port Poe Switch - 16 Port Poe Switch - Cpu Core Count 1 Cpu Nominal Frequency 800 Mhz Size Of Ram 256 Mb Storage Size 16 Mb Storage Type Flash Mtbf Approximately 200'000 Hours At 25c Cooling Type Passive Poe-out Ports Ether1-ether16 Poe Out 802.3af/at Max Out Per Port Output (input 18-30 V) 1.1 A Max Out Per Port Output (input 30-57 V) 0.6 A Max Total Out (a) 2.8a (18v-30v) & 1.4a (48v-57v) X2 10/100/1000 Ethernet Ports 16 Number Of 1g Ethernet Ports With Poe-out 16 Sfp+ Ports 2 Certification Ce, Eac, Rohs Ip Ip54 Warranty :1 Year 88 Unit Adjustable Stainless Steel Strapping Band - Adjustable Stainless Steel Strapping Band - Material: Stainless Steel 304 Width: 1/2 Inch Thickness: 0.5 Mm Length: 30 Meters 44 Unit Cable Loop Holder - Cable Loop Holder - Galvanized Steel Pole Mountable 4 Branches At Least 400mmx400mm 1 Box Cat6 Utp Pure Copper Outdoor Cable - Cat6 Utp Pure Copper Outdoor Cable - Cat6 Utp Pure Copper Outdoor Cable 40 Unit Cctv Channel License - Cctv Channel License - Single Anpr Camera Connection For Use With Central Software Warranty :perpetual Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 1 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 40 Unit Cctv Lpr Camera - Cctv Lpr Camera - Camera Image Sensor 1/1.8″ Progressive Scan Cmos Max. Resolution 2688 × 1520 Min. Illumination Color: 0.001 Lux @ (f1.2, Agc On) Shutter Time 1/25 S To 1/100,000 S Day & Night Ir Cut Filter Lens Focal Length & Fov 2.8-12 Mm: Horizontal: 113.5° To 39°, Vertical: 58.4° To 22.7°, Diagonal: 141.3° To 44.3° Aperture 2.8-12 Mm: F1.38, 8-32 Mm: F1.7, 10-50 Mm: F1.7 Illuminator Built-in Supplement Light Type Ir Light Built-in Supplement Light Range Up To 40 M Ir Wavelength 850 Nm Video Main Stream 50 Hz: 25 Fps (2688 × 1520, 1920 × 1080, 1280 × 760, 704 × 576, 352 × 288) 60 Hz: 30 Fps (2688 × 1520, 1920 × 1080, 1280 × 760, 704 × 576, 352 × 288) Sub-stream 50 Hz: 25 Fps (1920 × 1080, 1280 × 760, 704 × 576, 352 × 288) 60 Hz: 30 Fps (1920 × 1080, 1280 × 760, 704 × 576, 352 × 288) Video Compression H.264 And H.265 Encoding Main Stream: H.265/h.264/mjpeg Sub-stream: H.265/h.264/mjpeg Video Bit Rate 32 Kbps To 16 Mbps Protocols Tcp/ip,icmp,http,https,ftp,sftp,dhcp,dns,ddns,rtp,rtsp,rtcp,ntp,smtp,snmp,igmp,qos,ipv4/ipv6,udp,ssl/tls,isup,arp,802.1x Simultaneous Live View Up To 6 Channels Road Traffic And Vehicle Detection Coverage Up To 3 Lane(s) Smart Function Traffic Flow Detection:average Speed, Traffic Flow, Queuing Length, And Traffic Status Incident Detection: Congestion, Stopped Vehicle, Lane Change, Wrong-way Driving, Speeding, Low-speed Driving Capture Speed Range 5 To 120 Km/h Blocklist And Allowlist Max. 50000 Records Warranty :2 Years Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 2 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 5 Unit Cctv Nvr - Cctv Nvr - Supports Redundant Power Supply To Improve The System Stability Supports Hdd Hot Swap With Raid0, Raid1, Raid5, Raid 6, And Raid10 Storage Scheme Configurable. Either Normal Or Hot Spare Working Mode Is Configurable To Constitute An N+1 Hot Spare System. Supports Some Specialist Cameras, Including People Counting Camera/anpr (automatic Number Plate Recognition) Camera/fisheye Camera Supports Video Analytic Functions Such As Vehicle Detection, License Plate Recognition --video & Audio Input -ip Video Input 128-ch -incoming/outgoing Bandwidth 576 Mbps/512 Mbps -incoming/outgoing Bandwidth (raid Mode) 576 Mbps/512 Mbps -tls Outgoing Bandwidth 128 Mbps, Or 64 Mbps (when Raid Is Enabled) --video & Audio Output -protocol Hikvision, Acti, Arecont, Axis, Bosch, Brickcom, Canon, Hunt, Onvif (version 2.5), Panasonic, Pelco, Rtsp, Samsung, Sony, Vivotek, Zavio --video & Audio Output -hdmi Output Two Independent Hdmi Outputs Of 4k Resolution. Resolution: 4k (4096 × 2160), 4k (3840 × 2160)/30hz, 2k (2560 × 1440)/60hz, 1080p (1920 × 1080)/60hz, Uxga (1600 × 1200)/60hz, Sxga (1280 × 1024)/60hz, 720p (1280 × 720)/60hz, Xga (1024 × 768)/60hz -vga Output 1-ch. Resolution: 1080p (1920 × 1080)/60hz, Uxga (1600 × 1200)/60hz, Sxga (1280 × 1024)/60hz, 720p (1280 × 720)/60hz, Xga (1024 × 768)/60hz --video & Audio Decoding -decoding Format H.265, H.265+, H.264, H.264+, Mpeg4, Mjpeg (for Hikvision Ip Camera Only) -video Resolution 32 Mp/24 Mp/12 Mp/8 Mp/7 Mp/6 Mp/5 Mp/4 Mp/3 Mp/1080p/uxga/720p/vga/4cif/dcif/2cif/cif/qcif *: 32 Mp And 24 Mp Is Only Available For Channel 1 To 4 When Ultra Hd Resolution Mode Is Enabled -synchronous Playback Up To 16 Channels -capability 1-ch@32 Mp (8160 × 3616, 30 Fps)/5-ch@8 Mp(30 Fps)/10-ch@4 Mp(30fps)/20-ch@1080p(30 Fps)/40-ch@720p(30 Fps) *: The Length Or Width Of Camera Resolution (each Track) Cannot Exceed 4096 Pixels --hdd -interface 16 Sata Interfaces Supporting Hot-plug -capacity Up To 10 Tb For Each Hdd -storage Extension 1 × Esata Interface, 2 × Mini Sas Interface (optional) --raid Raid Type Raid0, Raid1, Raid5, Raid 6, And Raid10 --network Management -protocol Ipv6, Https, Upnp, Snmp, Ntp, Sadp, Smtp, Nfs, Iscsi, Pppoe, Ddns Network Interface 4, Rj45 10m/100m/1000m Self-adaptive Ethernet Interface --external Interface -usb Interface Front Panel: 2 × Usb 2.0; Rear Panel: 2 × Usb 3.0 Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 3 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) -alarm Input/output 16/8 --general -power Supply 100 To 240 Vac, 50 To 60hz, 5 A -fan Redundant Dual Ball Bearing Fan; Speed Adjustable -consumption (without Hdd) ≤ 140w -warranty :2 Years 1. Responsibility Of The Supplier 1.1 Supply And Delivery Of Ict Equipment 1.2 Inventory Of The Items Deliverd With The Following Details 1.2.1 Brand 1.2.2 Model 1.2.3 Serial Number 1.2.4 Quantity 1.3 The Bidder Must Ensure That All Components Delivered Will Be Brand New 1.4 All Equipment Provided Must Be Compatible And Working With The Cctv System As A Whole 1.5 Materials And Equipment Delivery Within 90 Days 1.6 Cctv Contractor Should Have Manufacture Authorization And Certification. 1.7 Contractor Must Have A Valid Iso 9001:2015 Certificate 1.8 All Equipment Provided Must Be Capable/compatible To Interconnect With The Existing Systems Located At The Smart City Command Center (sc3) To Be Viewable And Configurable In The Sc3. 80 Unit Cctv Nvr Surveillance Hard Drive - Designed And Built To Handle Heavy Surveillance Workloads Advanced Vibration Management Capacity 10tb Interface Sata 6 Gb/s Max. Sustained Transfer Rate Od (mb/s) 250mb/s Cache (mb) 256 Tarnish Resistant Yes Mtbf 1,500,000 Hr Warranty :2 Years 15 Set Command Center Desktop Computer - Minimum Specifications: Operating System: Microsoft Windows 11 Pro 64bit Processor: Intel Core I5 14600k Turbo Frequency 5.3ghz 14 Cores/20 Threads, 24mb Cache, Socket Lga1700 Cpu Air Cooler: Twin Tower Cpu Air Cooler, With 6x6mm Sintered Copper Heatpipes, With 2x140mm Fans Motherboard: B760 Chipset, Lga1700 Socket, Ddr5 4xdimm Matx Form Factor Ram: Ddr5 5600mhz, 32gb (dual 2x16gb) Memory Modules Gpu: Rtx 4070, 12gb Gddr6/gddr6x Ssd: 512gb Capacity R/w 560/520 Mb/s 3d Tlc Ssd 2.5 Inch Form Factor Hdd: Capacity 2tb, 7200 Rpm, 256mb Cache, 3.5 Inch Form Factor Power Supply: 1000 Watts, 80 Plus Gold Certified, Fully Modular, With 120mm Smart Hydraulic Bearing (hyb) Fan, With Active Pfc, Mtbf: >100,000 Hours Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 4 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) Case: Tempered Glass Mid Tower Atx Case With At Least 3 Fans Monitor: 2 Units, 24 Inches, Resolution: Fhd 1920 X1080, Aspect Ratio:16:9, Brightness: 250cd, Color Gamut Ntsc 72%, Refresh Rate: 100hz, Response Time: 5ms(gtg), Connectivity: 1x Hdmi 1x Displayport Keyboard: Usb Connectivity, With Backlight, Rubber Dome, Usb Connectivity, Multi-key Anti-ghosting, Polling Rate: 1000hz, Cable Type: Attached, Braided, Cable Length: 5.9ft Mouse: Usb Connectivity, Optical Sensor, Mouse Button Durability: 30m L/r Click, Cable: 1.8m Tangle Free Rubber, Dpi: 12,400 Dpi Ups: Max Configurable Power (watts) 650 Watts / 1.2kva, At Least 3 Universal Socket Warranty :2 Years 2 Unit Command Center Field Laptop - Command Center Field Laptop - Intel Core I7-13700hx Processor (30 Mb Smart Cache, 2.1 Ghz Performance-core With Turbo Boost Max Technology 3.0 Up To 5.0 Ghz, Overclock Capable) 1x 16gb Of Ddr5 4800mhz System Memory, Upgradable To 32 Gb Using Two Sodimm Modules 2x 512gb Nvme Ssd; Total Of 1tb 16 Display With Ips (in-plane Switching) Technology, Wqxga 2560 X 1600, High-brightness (500 Nits) Nvidia® Geforce Rtx 4060 With 8 Gb Of Dedicated Vram Warranty :2 Years 2 Unit Command Center Printer - Command Center Printer - A3 Wi-fi Duplex All-in-one Ink Tank Printer Print Speed Of Up To 25.0 Ipm Prints Up To A3+ (for Simplex) Automatic Duplex Printing Ultra-high Page Yield Of 7,500 Pages (black) And 6,000 Pages (colour) Wi-fi, Wi-fi Direct, Ethernet Printer Type: Print, Scan, Copy, Fax With Adf Minimum Ink Droplet Volume: 3.8 Pl Print Direction: Bi-directional Printing Nozzle Configuration:800 X 1 Nozzles Black, 256 X 1 Nozzles Per Colour (cyan, Magenta, Yellow) Maximum Resolution: 4800 X 2400 Dpi Automatic 2-sided Printing: Yes (up To A3) Print Speed: Photo Default - 10 X 15 Cm / 4 X 6 " *1: Approx. 43 Sec Per Photo (border) / 52 Sec Per Photo (borderless)*2 Draft, A4 (black / Colour): Up To 32.0 Ppm / 22.0 Ppm *2 Iso 24734, A4 Simplex (black / Colour): Up To 25.0 Ipm / 12.0 Ipm *2 Iso 24734, A4 Duplex (black / Colour): Up To 16.0 Ipm / 9.0 Ipm *2 Iso 24734, A3 Simplex (black / Colour): Up To 13.5 Ipm / 6.0 Ipm *2 Iso 24734, A3 Duplex (black / Colour): Up To 10.0 Ipm / 5.0 Ipm *2 Warranty :1 Year Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 5 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 1 Unit Command Center Video Wall Controller - Command Center Video Wall Controller - Interface Alarm In Alarm Out 8-ch Alarm Out 8-ch Alarm In Serial Interface Rs-232 (rj45) × 1, Rs-485 × 1 Usb Interface Usb 2.0 × 2 Network Interface Rj45 × 2, 10 M/100 M/1000 Mbps Self-adaptive Ethernet Interface Optic Interface × 2 100 Base-fx/1000 Base-x Supports Optoelectronic Self-adaptation Video Walls 1 Video Wall Size <= 8 Layers Per Screen 1080p × 3 Or 4k × 1.5 Layers Layers Per Screen × Output Interface(s) Split Window Yes Scene Auto-switch Delay 3s Auto-switching Plans Support 256 Auto-switching Plans Max. Input Resolution 4k Audio Encoding Format G722.1, G711u, G711a, Aac-lc Video Output Interface Type Hdmi 1.4 Video Output Interface(s) 8 Video Decoding Resolution Up To 32 Mp Warranty:2 Years 8 Unit Command Center Video Wall Display - Command Center Video Wall Display - Display Panel Diagonal Size Class 55 Measured 54.6 Resolution 3,840 X 2,160 (16:9) Brightness (typ.) 700 Nit Orientation Landscape/portrait Haze 25% Contrast Ratio (typ.) 4,000:1 Type Va Active Display Area 1,209.6 (h) X 680.4 (v) Pixel Pitch (mm) 0.315 X 0.315 Color Gamut Ntsc 72% Operation Hour 24/7 Connectivity / Sound Input Video Dp 1.2 (1), Hdmi 2.0 (3) Audio N/a Usb Usb 2.0 X 2 Tuner N/a Output Audio Stereo Mini Jack Wifi / Bt O/o External Control Rs232c (in/out), Rj45 Speaker 10w 2ch Mechanical Spec Dimension (mm / In.) With Heavy Duty Full Motion Tv Wall Mount Warranty :3 Year 44 Unit Din Rail Mount - Din Rail Mount - 35mm At Least 7.5mm Depth Aluminum 22 Unit Electrical Box Enclosure - Electrical Box Enclosure - Electricalbox Panel Box Metal Enclosure(ip66, Nema 4 & 12) 300x250x150 Mm W/ 2 Fans And Fan Filter With Pole Mount Bracket X1 Molded Case Circuit Breaker Mccb30a 220v 2 Pole Din Rail Mount Type X1 Residual Current Circuit Breaker 63a 220v With Grounding/earthing 2 Pole Din Rail Mount Type X1 Grounding Bus Bar With Insulator X1 Din Rail Mount Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 6 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 40 Roll Fiber Optic Connectivity - Fiber Optic Connectivity - Fiber Optic Connectivity 2.0 Kms 4 Core Fiber Optic Cable Maintenance Of Outside And Inside Plant Equipment To Smart City Command Center For 1 Year 1 Unit Fiber Optic Fusion Equipment - Fiber Optic Fusion Equipment - Fiber Alignment Core/cladding Motor Number 6 Motors Splicing Time 5s Heating Mode 15s, Can Be Customized According To The External Environment Fiber Type Single-mode Fiber (smf/g.652), Bif/g.657); Suitable For Single Mode, Multi-mode, Bare Fiber, Tail Fiber, Drop Cable, Jumper, Invisible Fiber Fusion; The Cladding Diameter 80-150μm Splicing Loss 0.02db(sm)、0.01db(mm)0.04db(ds/nzds) Splicing Mode Automatic Focusing Core Alignment, Conventional/high Precision Welding Splicing Way Automatic, Semi-automatic Opm Wavelength: 850nm、1300nm、1310nm、1490nm、1550nm、1625nm、980nm、1270nm、1577nm、1650nm/measurement Range: -50+26dbm Absolute Error: <0.3db (-50dbm ~+3dbm Range) Battery Capacity 7800mah Large Capacity Lithium Battery Charging Time ≤3.5; It Can Continuously Weld And Heat About 260 Cores Magnification 320x (x Or Y Axis Single Display) 200x (x And Y Axis Dual Display) Fiber Diameter Coating Diameter: 80-150μm/coating Diameter: 100-1000μm Cutting Length Coating Layer 250μm Below: 8-16mm/coating Layer 250-1000μm: 16mm Heat Shrink Tube 60mm、50mm、40mm、25mm Tensile Testing Standard 2n Display 5 Inch Tft Color Display Screen Return Loss Better Than 60 Db Product Protection Waterproof, Dustproof And Fall Proof Warranty :1 Year 44 Unit Fiber Patch Cord Single-mode 9/125 Sc/upc To Lc/upc - Fiber Patch Cord Single-mode 9/125 Sc/upc To Lc/upc - Fiber Patch Cord Single-mode 9/125 Sc/upcto Lc/upc3 Meter 44 Unit Fiber Patch Cord Single-mode Sc/upc To Sc/upc - Fiber Patch Cord Single-mode Sc/upc To Sc/upc - Fiber Patch Cord Single-mode Sc/upcto Sc/upc3 Meter 45 Unit Gigabit Rj-45 Surge Protector Arrester - Gigabit Rj-45 Surge Protector Arrester - Protects Your Ethernet Device From The Damage Of Lightning & Surge Gigabit 10/100/1000 Specification: Connectors: Rj-45 Material: Shielded Aluminum Alloy 44 Unit Grounding Bus Bar With Insulator - Grounding Bus Bar With Insulator - Grounding Bus Bar With Insulatorat Least 8 Way At Least 8x12mm² 2 Roll Grounding Cable Pure Copper Wire - Grounding Cable 4mm Pure Copper Wire Round Solid 100m Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 7 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 22 Unit Grounding Rod And Clamp Copper Plated - Grounding Rod And Clamp Copper Plated - "grounding Rod Full Set - (1pc Grounding Rod + 1 Pc Grounding Clamp) Size: Approximately 50cm Length X 0.9cm Diameter" 22 Unit Heavy Duty Surface Type Extension Outlet 4 Gang - Heavy Duty Surface Type Extension Outlet 4 Gang - Heavy Duty Surface Type Extension Outlet 4 Gang 15 Amperes Capacity/ Maximum 3,750watts 1 Lot Installation, Integrations And Configuration Of Outside Plant Equipment - Installation, Integrations And Configuration Of Outside Plant Equipment - Installation, Integrations And Configuration Of All Outside Plant Project Equipment In Outside Project Sites Outside Of The Smart City Command Center 1 Lot Installation, System Integrations And Configuration Of All Inside Plant Project Equipment - Installation, System Integrations And Configuration Of All Inside Plant Project Equipment In The Smart City Command Center Such As The Hikcentral Camera License, Integration To Existing Hikcentral Software And Integration Of Existing Cctv Cameras Into New Nvr 22 Unit Iot Box Panelbox Metal Enclosure (ip66,nema4 & 12) 500x300x200mm W/ 2 Fans And Fan Filter With Pole Mount Bracket X1 Heavy Duty Surface Type Extension Outlet 4 Gang Terminal Block Distribution 2 Input 4 Output Push-in Type 40 Unit Lpr Camera Arm Mount - Gi Pipe Extension Arm 1.5-3 Meters 40 Unit Lpr Camera Memory Card - Product Capacity Covering 128g The Storage Mediumis Tlc Particles Long Reading And Writing Times, Which Can Meet More Than 1000 Cycles Optimized For Long Time On-board Video Recording, Offering More Stable Reading And Writing Experience Operating Voltage 2.7v~3.6v Compatibility Sd 6.1 Working Life 1,000 Cycles Storage Medium Tlc Speed Class Write/read Speed 64gb:up To 35/100mb/s 128gb:up To 70/100mb/s256gb:up To 90/100mb/s Durability 10,000 Insertion/removal Cycles Uhs-i Sdr104 Type Sdxc 40 Unit Lpr Camera Vertical Pole Mount - Vertical Pole Mounting Bracket Installed On The Cross Bar Galvanized Steel Sheet And Steel Material With Surface Spray Treatment Can Be Used For New Bullet Camera Outdoor Greycolo Must Be Compatible With Cctv Camera 22 Roll Metal Flexible Conduit 1 Inch - Metal Flexible Conduit 1 Inch 30 Meters Per Roll 44 Unit Molded Case Circuit Breaker Mccb 30a - Molded Case Circuit Breaker Mccb 30a 220v 2 Pole Din Rail Mount Type 22 Unit Molded Case Circuit Breaker Mccb 63a - Molded Case Circuit Breaker Mccb 63a 220v 2 Pole Din Rail Mount Type 22 Unit Poe Switch Power Supply - Power Supply 48v 2a 96w With Us Plug Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 8 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 22 Unit Residual Current Circuit Breaker 63a 220v - Residual Current Circuit Breaker 63a 220v With Grounding/earthing 2 Pole Din Railmount Type 44 Unit Sfp+ Module Lc Connector Type - Gigabit Single-mode Wdm Bi-directional Sfp Module Spec: Lc Connector, Tx:1550nm/rx:1310nm, Single-mode, 20 Km 7 Roll Solidwire Awg#12 - Solidwire Awg#12 75m Per Roll Use For Termination Inside Iot Box 7 Roll Solidwire Awg#16 - Solid Wire Awg#16 75m Per Roll Use For Termination Inside Iot Box 66 Unit Terminal Block Distribution 2 Input 4 Output - Terminal Block Distribution 2 Input 4 Output Push-in Type This Is A Lot Bidding, Partial Bids Are Not Allowed Please Indicate Brands Of Offers And Attach Complete Technical Brochures In The Eligibility And Technical Proposal Please Indicate Unit Prices Of Offers In The Financial Proposal Bidders Must Possess Valid Mayor's/business Permit With A Relevant Line Of Business For Use Of Cmo Mitd Under Pr No. 1 Please Refer To Attached Terms Of Reference In The Associated Components Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature
Closing Date10 Jan 2025
Tender AmountPHP 15.5 Million (USD 267 K)

The City Government Of Baguio Tender

Telecommunication Services
Philippines
Details: Description Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-220 Bidding December 2, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Thirty (30) Calendar Days Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 1 1 Lot Communications Equipment 2,200,000.00 6 Unit Base Radio, Ntc-type Approved Equipment, 136-174 Mhz Frequency Range, 50 Watts Maximum Output Power, Programmable To Ntc Assigned Frequency Specifications General A. Frequency Range - Uhf: 400-470mhz*; Vhf:136-174mhz B. Channel Capacity- 48 (16 Channels Per Zone) C. Zone Capacity - 3 D. Channel Spacing - 12.5/25khz E. Operating Voltage - 13.6 V ± 15% F. Current Drain - Standby: Around 0.3a Receive: < 1>1ghz G. Weight - 1100g H. Dimensions - 164 X 43 X150 Mm I. Frequency Stability - ±0.5 Ppm J. Antenna Impedance - 50ω Receiver A. Sensitivity - Analog: 0.3µv (12db Sinad); 0.22µv (typical) (12db Sinad); 0.4µv (20db Sinad) Digital: 0.3µv/bers5% B. Selectivity - Tia-603: 60db @ 12.5khz/ 70db @ 25khz Etsi: 60db @ 12.5khz/ 70db @ 25khz C. Intermodulation - Tia-603: 70db @ 12.5/25khz Etsi: 65db @ 12.5/25khz D. Spurious Response Rejection- Tia-603: 70db @ 12.5/25khz Etsi: 70db @ 12.5/25khz E. Blocking- Tia-603: 90db Etsi: 84db E. Hum And Noise- 40db @ 12.5khz; 45db @ 25khz F. Rated Audio Power Output- Internal (@ 16 Ohm Load): 4w External (@8 Ohm Load): 8w Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry Brgy., Baguio City, January 10, 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 1 Of 5 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-220 Bidding December 2, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Thirty (30) Calendar Days Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) G. Max Audio Power Output - Internal (@16 Ohm Load): 6w External (@ 8ohm Load): 12w H. Rated Audio Distortion - ≤3% I. Audio Response - +1~-3db J. Conducted Spurious Emission - <-57dbm Transmitter A. Rf Power Output – Low Power Version: 1-25w (uhf/vhf) High Power Version: 5-45w (uhf) / 5-50w (vhf) B. Fm Modulation – 11kof3e @ 12.5khz; 16k0fe @ 25 Khz’ C. 4fsk Digital Modulation – 12.5khz Data Only: 7k60fxd 12.5khz Data & Voice:7k60fxw D. Conducted/radiated Emission - -36dbm<1ghz>1ghz E. Modulation Limiting- ±205khz @ 12.5khz F. Fm Hum & Noise- 40db @ 12.5khz 45db @ 25khz G. Adjacent Channel Power- 60db @ 12.5khz; 70db @ 25khz’ H. Audio Response- +1 ~ -3db I. Audio Distortion- ≤3% J. Digital Vocoder Type- Ambe+2™ Or Selp K. Digital Protocol- Etsi-tsi02 361-1, -2, -3 1 Lot Engineering Plans And Services (professional Fee) 30 Unit Handheld Radio (vhf), Ntc Type Approved Equipment, 136-174mhz Frequency Range, 5 Watts' Maximum Out-put Power, Programmable To Ntc Award Frequency. Accessories: 1. Belt Clip 2. Standard Desk Charger 3. Rubber Duck Antenna 4. Manual General: A. Frequency Range- Uhf: 400-470 Mhz, Vhf:136-174mhz B. Channel Capacity - 128 C. Zone Capacity - 8 D. Zone Channel - 16 E. Channel Spacing - 12.5khz/20kh/25khz F. Operating Voltage -7.4v G. Battery - 1500mah (standard); 2000mah (optional) H. Battery Life - (5/5/90 Duty Cycle, High Tx Power) - Analog: 12h (1500mah), 16h (2000mah) - Digital: 16h (1500mah), 21h (2000mah) I. Frequency Stability - ±0.5ppm J. Antennal Impedance - 50ω K. Weight (with Antenna & Battery) -230g L. Dimensions (h X W X D) - 115 X 55 X 295mm M. Display - 1.77 Inch Tft Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry Brgy., Baguio City, January 10, 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 2 Of 5 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-220 Bidding December 2, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Thirty (30) Calendar Days Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) Receiver: A. Sensitivity - Digital: 0.18µv / Bers % Analog: 0.18µv(12db Sinad) B. Adjacent Channel Selectivity - Tia -603: 60db@12.5khz, 70db@20/25khz Etsi: 60db@12.5khz, 70db@20/25khz C. Intermodulation- Tia- 603:70db@12.5/20/25khz Etsi: 65db@12.5/20/25khz D.spurious Response Rejection- Tia -603: 70db@ 12.5/20/25khz Etsi: 70db@12.5/20/25khz E. Blocking - Tia -603:80db Etsi: 84db F. Hum And Noise- 40db@20khz, 45db@25khz G. Rated Audio Power Output - 1w H. Rated Audio Distortion - <3>1ghz E. Modulation Limiting - +2.5khz@12.5khz, +4.0khz@20khz, 15.0khz@25khz F. Fm Hum&noise - 40db@12.5khz, 43db@20khz, 45db@25khz G. Adjacent Channel Power- 60db@12.5khz, 70db@20/25khz H. Audio Response- +1 To -3db I. Audio Distorted - ≤% J. Digital Vocoder Type - Ambe +2™ Environmental: A. Operating Temperature - -30°~+60°c B. Storage Temperature - -40°c~+85°c C. Esd - Iec 61000-4.2 (level 4) ±8kv (contact); ±15kv(air) D. Dust And Water Intrusion - Iec60529-ip54 E. Humidity - Mil -std-810g F. Shock And Vibration - Mil-std-810g 1 Lot Installation Of Communication Equipment 1 Unit Mini Duplexer (vhf) -tuned To Working Frequency, 50 Watts 7 Unit Mobile Radio (vhf) - Ntc-approved Type (commercial), 50w, Programmable To Ntc Assigned Frequency Frequency Range 136-174 Mhz, With Magnetic Mount Mobile Antenna 6 Lot Ntc Permit To Purchase/possess And Radio Station License 6 (six) Units Base Radio 30 Lot Ntc Permit To Purchase/possess And Radio Station License For 30 (thirty) Units Handheld Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry Brgy., Baguio City, January 10, 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 3 Of 5 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-220 Bidding December 2, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Thirty (30) Calendar Days Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 1 Lot Ntc Permit To Purchase/possess And Radio Station License For 1 (one) Unit Repeater 7 Lot Ntc Permit To Purchase/possess And Radio Station License For 7 (seven) Mobile Radio 1 Lot Programming, Commissioning/propagation And Testing And Delivery (30 Days) Additional Requirements: * Provide A Network Diagram That Is Applicable To The Area * With History/experience In The Installation Of A Working Communication System In The Area *accredited With Ntc-car 1 Unit Repeater (vhf), Ntc-type Approved Equipment, 136-174 Mhz Frequency Range, 50 Watts Maximum Output Power, Programmable To Ntc Assigned Frequency. Specifications: General A. Frequency Range - Uhf 1: 400-470mhz; Uhf 2: 450-520mhz; Uhf 3: 350-400mhz; Vhf: 136-174 Mhz B. Channel Capacity - 16 C. Channel Spacing - 12.5khz/20khz/25 Khz D. Operating Voltage - 13.6v±15% E. Current Drain - Standby: ≤0.8a; Transmit:≤11a F. Frequency Stability - ± O.5ppm G. Antenna Impedance - 50ω H. Duty Cycle - 100% I. Dimensions (h X W X D) - 88 X 483 X 366 Mm J. Weight - 8.5 Kg K. Lcd Display - 220 X 176 Pixels, 262000 Colors; 2.0 Inch, 4 Rows Receiver A. Sensitivity - Analog: 0.28µv (12 Db Sinad); 0.22µv (typical) 12db Sinad) 0.4 Μv (20db Sinad) Digital: 0.3µv/ber5% B. Adjacent Channel Selectivity- Tia-603: 65db @ 12.5 Khz; 75 Db @20/25khz Etsi: 65 Db @ 12.5 Khz; 75 Db @ 20/25khz C. Intermodulation- Tia -603: 75db @ 12.5/20/25khz Etsi: 70db @ 12.5/20/25khz D. Spurious Response Rejection Tia-603: 80db @ 12.5/20/25khz Etsi: 80db @ 12.5/20/25khz E. Hum And Noise - 40db@ 12.5khz; 43db@20khz; 45db@25khz F. Rated Audio Power Output - 0.5w G. Rated Audio Distortion- ≤3% H. Audio Response - +1 ~ -3db I. Conducted Spurious Emission - <-57dbm Transmitter Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry Brgy., Baguio City, January 10, 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 4 Of 5 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-220 Bidding December 2, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Thirty (30) Calendar Days Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) A. Rf Power Output - 5-50w B. Fm Modulation - 11k0f3e @ 12.5khz; 14k0f3e @ 20khz; 16k0f3e @ 25 Khz C. 45sk Digital Modulation - 12.5khz Data Only: 7k60fxd; 12.5khz Data And Voice:7k60fxw D. Conducted/radiated Emission - -36dbm ≤ 1ghz; -30dbm > 1ghz E. Modulation Limiting - ±2.5khz @ 12.5 Khz; ±4.0khz @ 20khz; ±5.0khz @ 25khz F. Fm Hum & Noise - 40db @ 12.5khz; 43db @ 20khz; 45db @ 25khz G. Adjacent Channel Power - 60db @ 12.5khz; 70db @ 20/25khz H. Audio Response - +1 ~ -3db I. Audio Distortion - ≤3% J. Digital Vocoder Type - Ambe +2™, Selp, Nvoc, Comm K. Digital Protocol - Etsi-ts102 361-1, -2-, -3 Environmental Specifications A. Operating Temperature - -30°c ~+60°c B. Storage Temperature - -40°c ~ +85°c Accessories: 1. 1 Unit Tx Antenna (2 Elements Of Variloop Antenna) Cut, Fold And Tuned To Ntc Tx Assigned Frequency 2. 1 Unit Rx Antenna (2 Elements Of Variloop Antenna) Cut, Fold And Tuned To Ntc Tx Frequency 3. 100 M Coax Cable Rg-8 (japan) 4. 4 Pcs. Pi-259 Connector (good Quality) 5. Regulated Power Supply (13.8 V Dc/30 Amp) 6. With Pt Mask Antenna And Repeater Cabinet This Is A Lot Bidding, Partial Bids Are Not Allowed Please Indicate Brands Of Offers And Attach Technical Brochures In The Eligibility And Technical Proposal Please Indicate Unit Prices Of Offers In The Financial Proposal Bidders Must Possess Valid Mayor's/business Permit With A Relevant Line Of Business In The Supply, Delivery And Installation Of Communications Equipment For Use Of Bfp Under Pr No. 2 Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry Brgy., Baguio City, January 10, 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 5 Of 5
Closing Date10 Jan 2025
Tender AmountPHP 2.2 Million (USD 37.9 K)

DEPT OF THE NAVY USA Tender

Others
United States
Details: Contact Information|4|n722.23|b4t|215-697-2008|rachel.m.opperman.civ@us.navy.mil| commercial Product Procurement Notice|5|||||| item Unique Identification And Valuation (jan 2023)|19|||||||||||||||||||| wide Area Workflow Payment Instructions (jan 2023)|16|invoice And Receiving Report Combo||tbd|n00383|tbd|tbd|tbd|see Schedule|||tbd|||||| navy Use Of Abilityone Support Contractor - Release Of Offeror Information (3-18))|1|| equal Opportunity (sep 2016)|2||| equal Opportuity For Workers With Disabilities (jun 2020)|2||| buy American-free Trade Agreements-balance Of Payments Program-basic (feb 2024)|11|||||||||||| contract Terms And Conditions Required To Implement Statutes Or Executiveorders--commercial Products And Commercial Services (nov 2024))|83|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| continued: Contract Terms And Conditions Required To Implement Statutes Or Executive Orders--commercial Products And Commercial Services (nov 2024))|15|||||||||||||||| offeror Representations And Certifications--commercial Products And Commercialservices (may 2024))|3|||| alternate A, Annual Representations And Certifications (oct 2024)|13|||||||||||||| buy American-free Trade Agreements-balance Of Payments Program Certificate-basic (feb 2024))|5|||||| buy American--balance Of Payments Program (feb 2024)|1|| royalty Information (apr 1984)|1|| annual Representations And Certifications (may 2024)|12|334511|1250||||||||||| notice Of Priority Rating For National Defense, Emergency Preparedness, Andenergy Program Use (apr 2008))|2||| evaluation--commercial Products And Commercial Services (nov 2021)|4||||| all Contractual Documents (i.e. Contracts, Purchase Orders, Task Orders,delivery Orders And Modifications) Related To The Instant Procurement Areconsidered To Be "issued" By The Government When Copies Are Either Deposited In The Mail, Transmitted By Facsimile, Or sent By Other Electronic Commercemethods, Such As Email. The Government's Acceptance Of The Contractor'sproposal Constitutes Bilateral Agreement To "issue" Contractual Documents Asdetailed Herein. early And Incremental Deliveries Accepted. all Terms And Conditions Are In Accordance With Boa:n0038321gym01 1. Scope 1.1 . Markings Shall Be In Accordance With Mil-std-130. 1.2 Articles To Be Furnished Hereunder Shall Be Repaired, Tested Andinspected In Accordance With The Terms And Conditions Specified In Therequirements Section Of This Document. 1.3 Unless Expressly Provided For Elsewhere In This Clause, Equipment Suchas Fixtures, Jigs, Dies, Patterns, Mylars, Special Tooling, Test Equipment, Orany Other Manufacturing Aid Required For The Manufacture And/or Testing Of The Subject Item(s) Will Not Be provided By The Government Or Any Other Source And Is The Sole Responsibility Of The Contractor. The Foregoing Applies Notwithstanding Any Reference To Such Equipment Or The Furnishing Thereof That May Be Contained In Any Drawing Or Referenced Specification. 1.4 The Use Of Mil-w-81381 Wire In Any Item To Be Delivered Under This Procurement Is Prohibited. The Foregoing Prohibition Applies Notwithstanding Any Reference To Mil-w-81381 Wire That May Be Made In Any Of The Drawings Or Specifications For This procurement. Sae-as22759 Series Wire Shall Be Used In Lieu Of Mil-w-81381 Wire, In Any Place Where Mil-w-81381 Wire Is Cited In This Procurement. Any Questions Concerning This Requirement Should Be Directed To The Procuring Contracting Officer. 1.5 If Mil-std-454 Is Referenced In The Drawings Or In The Specification,the Contractor Is Expected To Show Compliance With Ipc/eiaj-std-001c Personnel Performing Tasks In Accordance With Ipc/eiaj-std-001c Shall Be Trained And Certified As Requried By ipc/eiaj-std-001c Paragraph 5.1.4. 2. Applicable Documents - Not Applicable 3. Requirements the Contractor Shall Maintain A Quality Control System Which Meets The Requirements Of Mil-i-45208a, Mil-q 9858,iso-9000 / 9001 / 9002 Or Equivalent. responsibility For Inspection: Unless Otherwise Specified, The Contractor Is Responsible For The Performance Of All Inspection Requirements As Specified herein. Except As Otherwise Specified, The Contractor May Use His Own Or Any Other Facility Suitable For The Performance Of The Inspection Requirements Specified Herein. procedures:the Contractor Shall Prepare And Maintain Quality Control documentation, Test And Repair Procedures, And Inspection Procedures Which Shall Be Made Available To The Government For Review And Approval. The Procedures Shall Include Sequential Diagrams Of The Test, Repair, And Inspection Process, As Well As The performance Spcifications To Perform The Procedures. quality Assurance Program Plan: The Contractor Shall Develop, Implement And Maintain A Repair Quality Plan In Compliance With The Requirements Of Mil-i-45208a, Mil-q-9858, Iso,9000 / 9001 / 9002, Or Equvalent.the Plan Shall Define The Specific Methods By Which compliance With Contractual Requirements will Be Assured. All Quality Assurance Data Shall Be Provided To The Government For Review And Approval Upon Request. purchased Material Control: The Contractor Shall Establish And Maintain A System Of Control Over Purchased Material Which Shall Assure That The Necessary Requirements Of This Contract Are Included. In All Sub contract Agreements. A Parts Control System Shall Establish A Record Of Performance For Each Purchased And Internally Manufactured Part And Shall Be Used To Evaluate Continued Use Of The Source. The Contractors Control System Shall Be In Compliance Wil either Mil-i 45208a/mil-q-9858 Or Equivalent Quality Quality Assurance Standared.(iso/as:9000, 9001, 9002). receiving Inspection Of Purchased Material: Purchased Items Shall Be Inspected Upon Receipt At The Contractors Facility To Assure Conformance With All Requirements Of The Technical Data Package (tdp). Evidence Of Such Inspections Shall Be Maintained For government Review At Least Twelve (12) Months Following Acceptance Of The End Item. Inspection Reports Shall Be Maintained By The Contractor. The Inspection Report Shall, At A Minimum, Include A Record Of All Dimensional Data (coordinate/positional), Material, finish, And Process With Appropriate Pass/fail Criteria, Such Ascertifications, And Actual Dimensional Readings. failure Analysis And Corrective Action:all Failure Analysis And Corrective Action Reports/plans Shall Be Submitted To The Government. nonconforming Material:the Contractor Shall Establish An Effective System For Controlling Nonconforming Material Including Procedures For Identification, Segregation, And Disposition. contractor Internal Review Board (irb):irb Authority Is Delegated To The Contractor For This Contract Only. The Irb May Be Used Only For Disposition Of Materials Exhibiting Minor Non-conformances, Scrap Or Rework To Return A Part To Conformance With Drawings Or specifications As Authorized By The Approved Repair Procedures.irb Shall Not Use "as-is" Disposition. A Complete File Of Irb Actions Shall Be Maintained For Review By The Government For Concurrance Of Classification. material Review Board (mrb):formal Mrb Authority For Disposition Of "as-is"and For Minor Non-conformances Is Retained By The Government. The Contractor Shall Submit The Appropriate Request For Waiver/deviation Via The Dcmc To The Navicp Contracting Officer. responsibility For Compliance: All Items Must Meet All Requirements Of This Statement Of Work. The Inspection Requirements Set Forth In This Sow Shall Become Part Of The Contractors Overall Inspection System Or Quality Program. The Absence Of Any Inspection requirements In The Sow Shall Not Relieve The Contractor Of The Responsibility Of Assuring That All Government Equipment Submitted For Acceptance Comply With All Requirements. Sampling In Quality Conformance Does Not Authorize Submission Of Known Defective items, Either Indicated Or Actual, Nor Does It Commit The Procuring Activity To Acceptance Of Any Defective Items. repair Assessment Testing: The Government May Select Samples Of The Contract Line Items (clins) Which Have Completed Repair And Have Been Accepted By The Government Representative For The Purpose Of Conducting Performance Testing, Environmental Testing, And quality Conformance Examination In A Repair Assessment Test Program. A Quantity Of Clin's May Be Randomly Selected From Each Quaterly Repair Production Completion For Shipment To The Cfa Or Other Government Designated Location To Conduct This Testing. records Of Data Collection: The Contractor Shall Maintain A Historical Record File To Contain Copies Of Applicable Data And Documents For Individual Clin's and Assemblies By Clin Serial Number. The Historical Record File Shall Include,but Not Be Limited To The Following Types Of Historical Records: receipt Inspection Documentation. repair Shop Travelers Or Repair Cards. parts Replacement Records. parts Inspection Data Before And After Repair As Applicable. acceptance Test Data. qa Personnel Shall Maintain A Complete Receipt Inspection,test, Repair re-test, History Card For Each Item Processed. This Information Shall Be Made Available To The Government Upon Request. 3.1 1.0 General 3.1.1 This Statement Of Work (sow) Establishes The Criteria For Repair And Testing /inspection Of The Subject Item. It Includes Inspection, Component Repair And Replacement,reassembly And Testing Procedures Required To Return Units Back Into A Servicable condition. 3.2 2.0 Definitions. 3.2.1 Contractor: Is Defined As The Successful Offeror Awarded A Contract, Orderor Issued A Project Work Order. The Term "contract" Encompasses A Contract, An Order, Or A Project Work Order. 3.2.2 Overhaul: An Overhauled Part Is One Which Has Been Disassembled, Cleaned, Inspected, Repaired As Necessary (by Replacing Or Repairing All Components Which Have Been Found To Exceed Limits Established By The Repair/overhaul Manual) Reassembled And Tested in Accordance With The Approved Repair/overhaul Manual Listed In This Sow And Returned To A Ready For Issue (rfi) Condition (refer To Contract Schedule For Items To Be Overhauled). 3.2.3 Repair: A Repaired Part Is One Which Has Been Restored To A Ready For Issue(rfi) Condition (by Replacing Or Repairing Those Components Found To Be Defective, Broken, Damaged Or Inoperative During The Initial Evaluation And Troubleshooting Phase) And tested In Accordance With The Approved Repair/overhaul Manual Listed In This Sow (refer To Contract Schedule For Items To Be Repaired). 3.3 3.0 Scope 3.3.1 General. The Items To Be Furnished Hereunder Shall Be Overhauled, Upgraded,repaired, Tested, Inspected, And Accepted In Accordance With The Terms And Conditions Specified In This Contract. Unless Expressly Provided Government Furnished Property, including Equipment Such As Fixtures, Jigs, Dies, Patterns, Mylars, Special Tooling, Special Test Equipment, Or Any Other Manufacturing Aid Required For The Repair, Manufacture, And/or Testing Of The Subject Item(s) Will Not Be Provided By The Government And shall Be The Responsibility Of The Contractor. The Foregoing Applies Notwithstanding Any Reference To Such Equipment Or The Furnishing Thereof That May Be Contained In Any Drawing, Manual, Or Specification For The Contract Items. 3.3.2 Repair Upgrade Requirements:the Contractor Shall Provide The Necessary facility, Labor, Materials, Parts, And Test And Tooling Equipment Required To To Return The Following Items To A Ready For Issue (rfi) Condition: indicator,attitude ;501-1757-01; P/n, ;014323229; Nsn, ;iaw Applicable Manuals.; Tech Publications 3.3.3 Rfi Is Defined As That Condition Allowing The Items To Perform Properly And Reliably In An Operational Environment In A Manner They Were Intended To Operate.the Contractor Must Perform All Repairs/upgrades At The Facility Identified Within This Sow. repairs Performed By The Contractor Or Subcontractor Shall Be Performed In Accordance With The Specified Drawings And Repair Manual(s). 3.4 Changes To Such Manuals Used For Repairs Under This Contract, Or Changes To Drawings Or Specifications Used In The Manufacture Of Parts Utilized In These Repairs, Require Procuring Contracting Officer (pco) Approval In Accordance With The Configuration management Provisions Of This Statement Of Work Or Contract. Under No Circumstances Should The Repair, Test, And Inspection Extend Beyond The Requirements Of This Paragraph Unless Authorized By The Government Qar.in Addition, Requests For Approval Of Changes to A Repair Source Or Repair Facility Shall Be Submitted In Writing To The Pco Prior To Making Any Such Change. 3.4.1 Any Repairs Performed Using Unapproved Changes To Such Manuals, Drawings, Specifications, Or Changes To Repair Source Or Facility Are Done At The Contractor's Own Risk. If The Government Disapproves The Requested Change, The Contractor Shall Replace Any delivered Items Repaired Using Such Unapproved Manuals,drawing, Specification, Repair Source Or Repair Facility Change. The Contractor Is Not Entitled To Any Equitable Adjustment To The Contract Price Or Terms Based On The Government's Disapproval Of A requested Change To Manuals, Drawings, Specifications, Or To A Repair Source Or Facility. 3.4.2 References On Drawings And Specifications:for Repair And Overhaul Purposes Only. All References To The "prime Contractor" Or The "actual Manufacturer" Appearing On The Drawings And / Or Specifications Or Technical Data Furnished By The Government Shall Be read As The "government Designated Agency" 3.4.3 Process Control Documentation: The Contractor Shall Prepare And Maintain Repair Procedures, And Test / Inspection Information / Procedures Which Shall Be Made Available To The Government For Review And Approval. The Procedures Shall Include Sequential diagrams Of Processes, As Well As The Performance Specifications To Perform The Testing / Inspection Procedures. Those Processes Shall Be Frozen After Approval Of The Inspection / Test. 3.4.4 Beyond Economical Repair (ber). An Item Is Ber If The Cost Of The Repair Exceeds 75% Of The Production Quantity Price To Replace The Item, Current At Time Of Award. This Replacement Price Is For The Purposes Of Ber Determinations Only, And May Not Be used Or Relied On By The Offeror In The Pricing Of The Repairs Required By This Contract. Items Determined Ber Are Not Included In The Contract Price. The Contractor Shall Obtain Written Concurrence From Dcma For All Units Determined By The Contractor To Be ber. All Such Determinations, Including The Basis For The Determination, The Repair Required, The Proposed Price To Repair And The Dcma Written Concurrence Shall Be Provided By The Contractor To The Pco, With A Copy To The Inventory Manager. After Receipt Of the Required Documentation, The Pco Shall Provide The Contractor Disposition Instructions Or Contractual Authority For Repair Of The Item. The Contractor Is Not Authorized To Proceed With The Repair Until Notification To Proceed Is Received From The Pco. Any disposal Ordered Shall Be Performed By The Contractor In Accordance With All Applicable Regulations And In Accordance With All Dcma Disposal Procedures And Requirements. 3.4.5 Missing On Induction (moi). A Weapons Repairable Assembly (wra) Is Subject To This Moi Provision If The Item Received By The Contractor For Repair Is Missing One Or More Shop Replaceable Assemblies (sras). Contractor Replacement Of Moi Sras Is Not included In The Contract Price. The Contractor Shall Immediately Notify Dcma When An Item Is Received With Moi Sra(s) And Shall Obtain Written Verification From Dcma For All Wras Determined To Have Moi Sra(s). The Contractor Shall Provide All Such determinations, Including Identification Of The Missing Sra(s), And The Dcma Written Verification, To The Inventory Manager With A Copy To The Pco And Aco Prior To Induction And/or Repair Of The Wra. The Contractor Shall Not Induct And/or Repair Wras With Moi sras Until Instructions On How To Proceed Are Provided To The Contractor By The Inventory Manager (where No Adjustment Price To The Contract Is Required) Or By The Pco. Items Received By The Contractor Missing Consumable Parts Are Not Moi Items. Rather, repair Of Such Items And Replacement Of The Missing Consumable Parts Are Included In The Contract Price And The Item Shall Be Inducted And Repaired By The Contractor Under This Contract. 3.4.6 Replacing Failed Or Missing Shop Replaceable Assembly (sra) When Repairinga Weapons Replaceable Assembly (wra). 3.4.7 A. When The Contractor Believes One Or More Sra(s) Within A Wra Are Either: 3.4.8 Beyond Economic Repair (ber) Or Beyond Repair (br) I. E. The Unit Is Not Capable Of Being Repaired Because Of The Extent Of Physical Damage), Or Missing On Induction (moi), The Contractor Shall Obtain Written Verification From Dcma And Advice From The inventory Manager Whether A Sra May Be Replaced By One Or More Of The Following Options: Ship In Place From An Existing Spares Or Repair Contract, If Any, Milstrip The Sra(s), Otherwise Be Provided Direction For Obtaining The Sra(s) At No Cost To The contractor.the Detailed Procedures Are Set Forth In Section 6.0 Of The Web-based Commercial Asset Visibility (cav) Statement Of Work. 3.4.9 B.when Not Otherwise Provided For (or Precluded) By Other Terms Of This Contract, The Contractor May Seek Written Authorization To Replace Failed Sra(s) With Ready For Issue Sra(s). When Authorized, The Procedures Set Forth In Paragraph 3.0 Of Section 6.2 Of The Web-based Commercial Asset Visibility (cav) Statement Of Work Shall Be Followed. 3.4.10 Over And Above Repair (oar). An Item Sent To The Contractor Shall Be Considered To Require Over And Above (oar) Repair Effort If The Repair Required Is Not The Type Of Repair That Would Be Anticipated As A Result Of Normal Navy Operation Of The Item And is Not Included In The Contract Pricing Due To The Nature Or Scope Of The Repair Needed For That Particular Item. Therefore, Repair Of Oar Items May Be Subject To Equitable Adjustment. The Contractor Shall Obtain Written Concurrence From Dcma For All Units determined By The Contractor To Require Oar Effort. All Such Oar Determinations, Including The Basis For The Determination, The Repair Required, The Proposed Price To Repair And The Dcma Written Concurrence, Shall Be Provided By The Contractor To The Pco Prior to Undertaking Repair Of The Item. after Receipt Of The Required Documentation, The Pco Shall Provide The Contractor Disposition Instructions Or Contractual Authority For Repair Of The Item. Any Ordered Disposal Shall Be Performed By The Contractor In Accordance With All Applicable Regulations and Dcma Disposal Procedures And Requirements. 3.5 4.0 Parts And Materials 3.5.1 General. The Contractor Is Responsible For Supplying All Parts And Material Necessary To Perform The Required Repairs Under This Contract Unless Parts Or Material Are Specifically Identified As Government Furnished Material (gfm). All Parts And Material used In Performance Of This Contract Shall Be In Accordance With The Latest Approved Revision Of Applicable Drawings And Specifications And Shall Be New In Accordance With Far 52.211-5, Material Requirements, Which Is Incorporated By Reference Herein. authorization To Use Other Than New Material As Defined By Far 52.211-5 Requires Written Approval From The Pco. In Addition, Cannibalization Must Be Approved By The Pco. Cannibalization Of Units That Have Not Been Inducted Is Not Typically Authorized And requires Specific Approval By The Pco. 3.5.2 The Contractor Shall Ensure It Has Access For The Duration Of This Contract To Updated Drawings And Specifications For Parts And Material Required For Repairs Performed Under This Contract. Any Change To Such Parts/material Drawings Or Specifications requires Government Approval In Accordance With The Configuration Management Provisions Of This Statement Of Work. Written Approval From The Pco Must Be Obtained Prior To Any Change To The Manufacturing Source Or Manufacturing Facility For All Parts Which require Source Approval, Unless The Contractor Is The Design Control Agent (dca) (i.e. The Entity Responsible For Maintaining The Latest Configuration Data) For The The Contract Item. If The Contractor Is The Dca, The Contractor May Approve Approve Changes To manufacturing Source Or Manufacturing Facility For All Parts, Including Those Which Require Source Approval. Any Repairs Performed Using Unapproved Changes To Such Drawings, Specifications Or Manufacturing Source Or Facility Are Done At The Contractor's Own risk. If The Government Disapproves The Requested Change, The Contractor Shall Replace Any Delivered Items Repaired Using Such Unapproved Change. The Contractor Is Not Entitled To Any Equitable Adjustment To The Contract Price Or Terms Based On The government's Disapproval Of A Requested Change To The Drawings, Specifications Or Manufacturing Source Or Facility. 3.5.3 Purchased Material Control And Parts Control. The Contractor Shall Establish And Maintain A System Of Control Over Purchased Parts And Material. Such Controls Shall, At A Minimum, Assure That The Parts And And Material Purchased Are In Compliance With The requirements Of This Contract. 3.5.4 Receiving Inspection Of Purchased Parts And Material. (1)purchased Items Shall Be Inspected Upon Receipt At The Contractor's Facility To Assure Conformance With All Requirements Of The Applicable Drawings And Specifications Or (2)the Contractor Shall provide Prior To The Contract Award Evidence For Government Review And Approval Of A Purchased Parts And Material System Which Provides For The Inspections To Assure Conformance With All Requirements Of The Applicable Drawings And Specifications. Evidence Of such Inspections Of Such Inspections Shall Be Maintained By The Contractor Or Subcontractor For Government Review.the Inspection Report Shall, At A Minimum, Include A Record Of All Dimensional Data (coordinate/positional), Material, Finish, And Process With appropriate Pass/fail Criteria Such As Certifications and Actual Dimensonal Readings. 3.5.5 ^^^note^^^part Cannibalization Is Not Authorized Unless Specifically Approved By Navsup Wss And The Bde. 3.5.6 3.6 Source And Location Of Repair Source: 3.6.1 The Contractor Shall Specify The Name Of The Source/division Performing The Work And The Actual Location Where Work Will Be Performed. indicator,attitude ;l3 Aviation Products Inc.; Company Name , ;5353 52nd St Se, Grand Rapids Mi 49512; Address , ;25583; Cage Code inspection Will Be Accomplished On The Contractor's Equipment 3.7 5.0 Contractor Quality Requirements: 3.7.1 Quality Program. The Contractor Shall Establish, Implement, Document And Maintain A Quality System That Ensures Conformance To All Applicable Requirements Of Iso 9001/ Sae As9100. The Contractor's Quality Management System/program Shall Be Designed To promptly Detect, Correct And Prevent Conditions That Adversely Affect Quality. 3.7.2 Calibration System Requirements. Contractor Shall Maintain A Calibration System That Meets The Requirements Of Ansi/ncsl Z540.3, Iso-10012-1 Or An Equivalent Calibration Program Acceptable To The Government. 3.8 6.0 Configuration Management (cm): 3.8.1 The Contractor Shall Maintain A Configuration Management Plan In Accordance With The Provisions Of Navsup Wss Configuration Management Clause Navicpia18. (refer To Contract). 3.9 7.0 Markings. 3.9.1 Marking Shall Be As Indicated In The Contract When Applicable. 3.10 8.0 Storage; 3.10.1 The Contractor Shall Provide A Proper Enclosed Warehouse Environment For Both Material Items Awaiting Repair And Assets Which Have Been Repaired And Are Awaiting Shipment To Ensure The Items Are Not Damaged While Being Stored. 4. Quality Assurance Provisions - Not Applicable. 5. Packaging- Mil-std 2073 Packaging Applies As Found Elsewhere In The Schedule 6. Notes - Not Applicable
Closing Date2 Jan 2025
Tender AmountRefer Documents 

DEPT OF THE NAVY USA Tender

Others
United States
Details: Contact Information|4|n791.03|lpg|215-697-0288|mackenzie.cannataro.civ@us.navy.mil| commercial Item Procurement Notice - Award|4||||| commercial Product Procurement Notice|5||x|||| item Unique Identification And Valuation (jan 2023)|19|||||||||||||||||||| higher-level Contract Quality Requirement|8||||||||| wide Area Workflow Payment Instructions (jan 2023)|16|invoice And Receiving Report Combo||tbd|n00383|tbd|tbd|see Schedule|tbd||||||||| navy Use Of Abilityone Support Contractor - Release Of Offeror Information (3-18))|1|| equal Opportunity (sep 2016)|2||| equal Opportuity For Workers With Disabilities (jun 2020)|2||| buy American-free Trade Agreements-balance Of Payments Program-basic (feb 2024)|11|||||||||||| notice Of Total Small Business Set-aside (oct 2020)(deviation 2020-o0008)|1|| contract Terms And Conditions Required To Implement Statutes Or Executiveorders--commercial Products And Commercial Services (nov 2024))|83|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| continued: Contract Terms And Conditions Required To Implement Statutes Or Executive Orders--commercial Products And Commercial Services (nov 2024))|15|||||||||||||||| offeror Representations And Certifications--commercial Products And Commercialservices (may 2024))|3|||| alternate A, Annual Representations And Certifications (oct 2024)|13|||||||||||||| buy American-free Trade Agreements-balance Of Payments Program Certificate-basic (feb 2024))|5|||||| buy American--balance Of Payments Program (feb 2024)|1|| royalty Information (apr 1984)|1|| annual Representations And Certifications (may 2024)|12|336413|1250||||||||||| notice Of Priority Rating For National Defense, Emergency Preparedness, Andenergy Program Use (apr 2008))|2||x| evaluation--commercial Products And Commercial Services (nov 2021)|4|price|rtat|past Performance|| the Purpose Of This Amendment Is To Incorporate A Picture Of The Item Needing Repair And To Clarify That This Requirement Is For The Repair Of The Entire Seat Assembly. repair Turnaround Time (rtat) Definition: The Contractual Delivery Requirement Is Measured From Asset Return To The Date Of Asset Acceptance Under The Terms Of The Contract. For Purposes Of This Section, Return Is Defined As Physical Receipt Of The F-condition asset At The Contractor's Facility As Reflected In Theaction Date Entry In The Commercial Asset Visibility (cav) System. In Accordance With The Cav Statement Of Work, The Contractor Is Required To Accurately Report All Transactions By The End Of The Fifth Regular Business Day After Receiptand The Action Date Entered In Cav Must Be Dated To Reflect The Actual Date Of Physical Receipt. the Contractor Must Obtain Final Inspection And Acceptance By The Government For All Assets Within The Rtats Established In The Subsequent Contract. required Rtat: 90 Days After Receipt Of Asset throughput Constraint: Contractor Must Provide A Throughput Constraint For Eachnsn(s). Total Assets To Be Repaired Monthly After Initial Delivery Commences X/month (contractor Fill In #). A Throughput Of ##____ Per Month Reflects No Throughput Constraint. induction Expiration Date: 365 Days After Contract Award Date. Any Asset Received After This Date In Days Is Not Authorized For Repair Without Bi-lateral Agreement Between The Contractor And Navsup Wss Contracting Officer. reconciliation:a Reconciliation Modification Will Be Issued After Final Inspection And Acceptance Of All Assets Inducted Under The Subsequent Contract. The Parties Have Agreed To A Price (shown On The Schedule Page) For Each Unit At The Negotiated Rtat. Such prices Are Based On The Contractor Meeting The Rtat Requirements Described Within The Schedule Page. If The Contractor Does Not Meet The Applicable Rtat Requirement, Consideration Will Be Assessed And Subject To Negotiation. all Contractual Documents (i.e. Contracts, Purchase Orders, Task Orders,delivery Orders, And Modifications) Related To The Instant Procurement Areconsidered To Be "issued" By The Government When Copies Are Either Depositedin The Mail, Transmitted By Facsimile, Or sent By Other Electronic Commercemethods, Such As Email. The Government's Acceptance Of The Contractor'sproposal Constitutes Bilateral Agreement To "issue" Contractual Documents Asdetailed Herein. early And Incremental Deliveries Accepted And Preferred. this Requirement Can Only Be Procured From A Supplier Who Provides Faa-certified Parts Which Possess A Faa Authorized Release Certificate, Faa Form 8130-3 Airworthy Approval Tag, From Certified Repair Stations Pursuant To 14 Cfr Part 14. this Solicitation Will Be Using Competitive Procedures. this Requirement Will Be Awarded To The Offeror With The Lowest Price Technically Acceptable (lpta) Submitted Via Quote. quotes May Be Emailed To The Below Email Address And Must Be Received By 4:30pm Est On The Closing Date, Listed In Block 10 On Page 1 Of This Solicitation. offers Received After The Closing Date Are Considered To Be Late And Will Not Be Considered For Award. the Government Intends To Make A Single Award To The Eligible, Responsible, Technically Acceptable And Responsible Offeror Whose Offer, Conforming To The Solicitation, Represents Best Value To The Government. The Offeror's Proposal Shall Be In The Form Prescribed By, And Shall Contain A Response To Each Of The Areas Identified In The Section L Solicitation Provision Entitled "submission Of Offers For Lowest Priced, Technically Acceptable Offers". Only Those Proposals Prepared In Accordance With The Solicitation Will Be E evaluated. Award Will Be Made On The Basis Of The Lowest Evaluated Price Of Proposals Meeting Or Exceeding Administrative Costs, It Is In The Government's Best Interest To Do So. The Government Will First Evaluate The Non-price Go/no Go Factors. The Non-price evaluation Factor Is Past Performance. The Non-price Factors Will Be Rated As Either Acceptable Or Unacceptable Based On The Solicitation Criteria. The Contractor Must Achieve An Acceptable Rating In Past Performance Or It Will Be Removed From Competition. this Requirement Is A 100 Percent Small Business Set Aside. \ 1. Scope 1.1 . Markings Shall Be In Accordance With Mil-std-130. 1.2 Articles To Be Furnished Hereunder Shall Be Manufactured, Tested And Inspected In Accordance With ;ipeco Holdings Limited; Drawing Number ( ;k9075; ) ;3a296-0007-21-1; , Revision ;latest; And All Details And Specifications Referenced Therein. 1.3 Unless Expressly Provided For Elsewhere In This Clause, Equipment Such As Fixtures, Jigs, Dies, Patterns, Mylars, Special Tooling, Test Equipment, Or Any Other Manufacturing Aid Required For The Manufacture And/or Testing Of The Subject Item(s) Will Not Be provided By The Government Or Any Other Source And Is The Sole Responsibility Of The Contractor. The Foregoing Applies Notwithstanding Any Reference To Such Equipment Or The Furnishing Thereof That May Be Contained In Any Drawing Or Referenced Specification. 1.4 If Mil-std-454 Is Referenced In The Drawings Or In The Specification, The Contractor Is Expected To Show Compliance With Ipc/eiaj-std-001c. 2. Applicable Documents - Not Applicable 3. Requirements 3.1 1.0 General 3.1.1 This Statement Of Work (sow) Establishes The Criteria For Repair And Testing /inspection Of The Subject Item. It Includes Inspection, Component Repair And Replacement,reassembly And Testing Procedures Required To Return Units Back Into A Servicable condition. 3.2 2.0 Definitions. 3.2.1 Contractor: Is Defined As The Successful Offeror Awarded A Contract, Orderor Issued A Project Work Order. The Term "contract" Encompasses A Contract, An Order, Or A Project Work Order. 3.2.2 Overhaul: An Overhauled Part Is One Which Has Been Disassembled, Cleaned, Inspected, Repaired As Necessary (by Replacing Or Repairing All Components Which Have Been Found To Exceed Limits Established By The Repair/overhaul Manual) Reassembled And Tested in Accordance With The Approved Repair/overhaul Manual Listed In This Sow And Returned To A Ready For Issue (rfi) Condition (refer To Contract Schedule For Items To Be Overhauled). 3.2.3 Repair: A Repaired Part Is One Which Has Been Restored To A Ready For Issue(rfi) Condition (by Replacing Or Repairing Those Components Found To Be Defective, Broken, Damaged Or Inoperative During The Initial Evaluation And Troubleshooting Phase) And tested In Accordance With The Approved Repair/overhaul Manual Listed In This Sow (refer To Contract Schedule For Items To Be Repaired). 3.3 3.0 Scope 3.3.1 General. The Items To Be Furnished Hereunder Shall Be Overhauled, Upgraded,repaired, Tested, Inspected, And Accepted In Accordance With The Terms And Conditions Specified In This Contract. Unless Expressly Provided Government Furnished Property, including Equipment Such As Fixtures, Jigs, Dies, Patterns, Mylars, Special Tooling, Special Test Equipment, Or Any Other Manufacturing Aid Required For The Repair, Manufacture, And/or Testing Of The Subject Item(s) Will Not Be Provided By The Government And shall Be The Responsibility Of The Contractor. The Foregoing Applies Notwithstanding Any Reference To Such Equipment Or The Furnishing Thereof That May Be Contained In Any Drawing, Manual, Or Specification For The Contract Items. 3.3.2 Repair Upgrade Requirements:the Contractor Shall Provide The Necessary facility, Labor, Materials, Parts, And Test And Tooling Equipment Required To To Return The Following Items To A Ready For Issue (rfi) Condition: seat,aircraft ;3a296-0007-21-1; P/n, ;7rh 1680 998899408 P8; Nsn, ;available Repair Manuals, Drawings And Specifications Per P/n Requirements; Tech Publications 3.3.3 Rfi Is Defined As That Condition Allowing The Items To Perform Properly And Reliably In An Operational Environment In A Manner They Were Intended To Operate.the Contractor Must Perform All Repairs/upgrades At The Facility Identified Within This Sow. repairs Performed By The Contractor Or Subcontractor Shall Be Performed In Accordance With The Specified Drawings And Repair Manual(s). 3.4 Changes To Such Manuals Used For Repairs Under This Contract, Or Changes To Drawings Or Specifications Used In The Manufacture Of Parts Utilized In These Repairs, Require Procuring Contracting Officer (pco) Approval In Accordance With The Configuration management Provisions Of This Statement Of Work Or Contract. Under No Circumstances Should The Repair, Test, And Inspection Extend Beyond The Requirements Of This Paragraph Unless Authorized By The Government Qar.in Addition, Requests For Approval Of Changes to A Repair Source Or Repair Facility Shall Be Submitted In Writing To The Pco Prior To Making Any Such Change. 3.4.1 Any Repairs Performed Using Unapproved Changes To Such Manuals, Drawings, Specifications, Or Changes To Repair Source Or Facility Are Done At The Contractor's Own Risk. If The Government Disapproves The Requested Change, The Contractor Shall Replace Any delivered Items Repaired Using Such Unapproved Manuals,drawing, Specification, Repair Source Or Repair Facility Change. The Contractor Is Not Entitled To Any Equitable Adjustment To The Contract Price Or Terms Based On The Government's Disapproval Of A requested Change To Manuals, Drawings, Specifications, Or To A Repair Source Or Facility. 3.4.2 References On Drawings And Specifications:for Repair And Overhaul Purposes Only. All References To The "prime Contractor" Or The "actual Manufacturer" Appearing On The Drawings And / Or Specifications Or Technical Data Furnished By The Government Shall Be read As The "government Designated Agency" 3.4.3 Process Control Documentation: The Contractor Shall Prepare And Maintain Repair Procedures, And Test / Inspection Information / Procedures Which Shall Be Made Available To The Government For Review And Approval. The Procedures Shall Include Sequential diagrams Of Processes, As Well As The Performance Specifications To Perform The Testing / Inspection Procedures. Those Processes Shall Be Frozen After Approval Of The Inspection / Test. 3.4.4 Beyond Economical Repair (ber). An Item Is Ber If The Cost Of The Repair Exceeds 75% Of The Production Quantity Price To Replace The Item, Current At Time Of Award. This Replacement Price Is For The Purposes Of Ber Determinations Only, And May Not Be used Or Relied On By The Offeror In The Pricing Of The Repairs Required By This Contract. Items Determined Ber Are Not Included In The Contract Price. The Contractor Shall Obtain Written Concurrence From Dcma For All Units Determined By The Contractor To Be ber. All Such Determinations, Including The Basis For The Determination, The Repair Required, The Proposed Price To Repair And The Dcma Written Concurrence Shall Be Provided By The Contractor To The Pco, With A Copy To The Inventory Manager. After Receipt Of the Required Documentation, The Pco Shall Provide The Contractor Disposition Instructions Or Contractual Authority For Repair Of The Item. The Contractor Is Not Authorized To Proceed With The Repair Until Notification To Proceed Is Received From The Pco. Any disposal Ordered Shall Be Performed By The Contractor In Accordance With All Applicable Regulations And In Accordance With All Dcma Disposal Procedures And Requirements. 3.4.5 Missing On Induction (moi). A Weapons Repairable Assembly (wra) Is Subject To This Moi Provision If The Item Received By The Contractor For Repair Is Missing One Or More Shop Replaceable Assemblies (sras). Contractor Replacement Of Moi Sras Is Not included In The Contract Price. The Contractor Shall Immediately Notify Dcma When An Item Is Received With Moi Sra(s) And Shall Obtain Written Verification From Dcma For All Wras Determined To Have Moi Sra(s). The Contractor Shall Provide All Such determinations, Including Identification Of The Missing Sra(s), And The Dcma Written Verification, To The Inventory Manager With A Copy To The Pco And Aco Prior To Induction And/or Repair Of The Wra. The Contractor Shall Not Induct And/or Repair Wras With Moi sras Until Instructions On How To Proceed Are Provided To The Contractor By The Inventory Manager (where No Adjustment Price To The Contract Is Required) Or By The Pco. Items Received By The Contractor Missing Consumable Parts Are Not Moi Items. Rather, repair Of Such Items And Replacement Of The Missing Consumable Parts Are Included In The Contract Price And The Item Shall Be Inducted And Repaired By The Contractor Under This Contract. 3.4.6 Replacing Failed Or Missing Shop Replaceable Assembly (sra) When Repairinga Weapons Replaceable Assembly (wra). 3.4.7 A. When The Contractor Believes One Or More Sra(s) Within A Wra Are Either: 3.4.8 Beyond Economic Repair (ber) Or Beyond Repair (br) I. E. The Unit Is Not Capable Of Being Repaired Because Of The Extent Of Physical Damage), Or Missing On Induction (moi), The Contractor Shall Obtain Written Verification From Dcma And Advice From The inventory Manager Whether A Sra May Be Replaced By One Or More Of The Following Options: Ship In Place From An Existing Spares Or Repair Contract, If Any, Milstrip The Sra(s), Otherwise Be Provided Direction For Obtaining The Sra(s) At No Cost To The contractor.the Detailed Procedures Are Set Forth In Section 6.0 Of The Web-based Commercial Asset Visibility (cav) Statement Of Work. 3.4.9 B.when Not Otherwise Provided For (or Precluded) By Other Terms Of This Contract, The Contractor May Seek Written Authorization To Replace Failed Sra(s) With Ready For Issue Sra(s). When Authorized, The Procedures Set Forth In Paragraph 3.0 Of Section 6.2 Of The Web-based Commercial Asset Visibility (cav) Statement Of Work Shall Be Followed. 3.4.10 Over And Above Repair (oar). An Item Sent To The Contractor Shall Be Considered To Require Over And Above (oar) Repair Effort If The Repair Required Is Not The Type Of Repair That Would Be Anticipated As A Result Of Normal Navy Operation Of The Item And is Not Included In The Contract Pricing Due To The Nature Or Scope Of The Repair Needed For That Particular Item. Therefore, Repair Of Oar Items May Be Subject To Equitable Adjustment. The Contractor Shall Obtain Written Concurrence From Dcma For All Units determined By The Contractor To Require Oar Effort. All Such Oar Determinations, Including The Basis For The Determination, The Repair Required, The Proposed Price To Repair And The Dcma Written Concurrence, Shall Be Provided By The Contractor To The Pco Prior to Undertaking Repair Of The Item. after Receipt Of The Required Documentation, The Pco Shall Provide The Contractor Disposition Instructions Or Contractual Authority For Repair Of The Item. Any Ordered Disposal Shall Be Performed By The Contractor In Accordance With All Applicable Regulations and Dcma Disposal Procedures And Requirements. 3.5 4.0 Parts And Materials 3.5.1 General. The Contractor Is Responsible For Supplying All Parts And Material Necessary To Perform The Required Repairs Under This Contract Unless Parts Or Material Are Specifically Identified As Government Furnished Material (gfm). All Parts And Material used In Performance Of This Contract Shall Be In Accordance With The Latest Approved Revision Of Applicable Drawings And Specifications And Shall Be New In Accordance With Far 52.211-5, Material Requirements, Which Is Incorporated By Reference Herein. authorization To Use Other Than New Material As Defined By Far 52.211-5 Requires Written Approval From The Pco. In Addition, Cannibalization Must Be Approved By The Pco. Cannibalization Of Units That Have Not Been Inducted Is Not Typically Authorized And requires Specific Approval By The Pco. 3.5.2 The Contractor Shall Ensure It Has Access For The Duration Of This Contract To Updated Drawings And Specifications For Parts And Material Required For Repairs Performed Under This Contract. Any Change To Such Parts/material Drawings Or Specifications requires Government Approval In Accordance With The Configuration Management Provisions Of This Statement Of Work. Written Approval From The Pco Must Be Obtained Prior To Any Change To The Manufacturing Source Or Manufacturing Facility For All Parts Which require Source Approval, Unless The Contractor Is The Design Control Agent (dca) (i.e. The Entity Responsible For Maintaining The Latest Configuration Data) For The The Contract Item. If The Contractor Is The Dca, The Contractor May Approve Approve Changes To manufacturing Source Or Manufacturing Facility For All Parts, Including Those Which Require Source Approval. Any Repairs Performed Using Unapproved Changes To Such Drawings, Specifications Or Manufacturing Source Or Facility Are Done At The Contractor's Own risk. If The Government Disapproves The Requested Change, The Contractor Shall Replace Any Delivered Items Repaired Using Such Unapproved Change. The Contractor Is Not Entitled To Any Equitable Adjustment To The Contract Price Or Terms Based On The government's Disapproval Of A Requested Change To The Drawings, Specifications Or Manufacturing Source Or Facility. 3.5.3 Purchased Material Control And Parts Control. The Contractor Shall Establish And Maintain A System Of Control Over Purchased Parts And Material. Such Controls Shall, At A Minimum, Assure That The Parts And And Material Purchased Are In Compliance With The requirements Of This Contract. 3.5.4 Receiving Inspection Of Purchased Parts And Material. (1)purchased Items Shall Be Inspected Upon Receipt At The Contractor's Facility To Assure Conformance With All Requirements Of The Applicable Drawings And Specifications Or (2)the Contractor Shall provide Prior To The Contract Award Evidence For Government Review And Approval Of A Purchased Parts And Material System Which Provides For The Inspections To Assure Conformance With All Requirements Of The Applicable Drawings And Specifications. Evidence Of such Inspections Of Such Inspections Shall Be Maintained By The Contractor Or Subcontractor For Government Review.the Inspection Report Shall, At A Minimum, Include A Record Of All Dimensional Data (coordinate/positional), Material, Finish, And Process With appropriate Pass/fail Criteria Such As Certifications and Actual Dimensonal Readings. 3.5.5 ^^^note^^^part Cannibalization Is Not Authorized Unless Specifically Approved By Navsup Wss And The Bde. 3.5.6 3.6 Source And Location Of Repair Source: 3.6.1 The Contractor Shall Specify The Name Of The Source/division Performing The Work And The Actual Location Where Work Will Be Performed. seat,aircraft ;ipeco Holdings Limited; Company Name , ;essex Ss2 6un United Kingdom; Address , ;k9075; Cage Code inspection Will Be Accomplished On The Contractor's Equipment 3.7 5.0 Contractor Quality Requirements: 3.7.1 Quality Program. The Contractor Shall Establish, Implement, Document And Maintain A Quality System That Ensures Conformance To All Applicable Requirements Of Iso 9001/ Sae As9100. The Contractor's Quality Management System/program Shall Be Designed To promptly Detect, Correct And Prevent Conditions That Adversely Affect Quality. 3.7.2 Calibration System Requirements. Contractor Shall Maintain A Calibration System That Meets The Requirements Of Ansi/ncsl Z540.3, Iso-10012-1 Or An Equivalent Calibration Program Acceptable To The Government. 3.8 6.0 Configuration Management (cm): 3.8.1 The Contractor Shall Maintain A Configuration Management Plan In Accordance With The Provisions Of Navsup Wss Configuration Management Clause Navicpia18. (refer To Contract). 3.9 7.0 Markings. 3.9.1 Marking Shall Be As Indicated In The Contract When Applicable. 3.10 8.0 Storage; 3.10.1 The Contractor Shall Provide A Proper Enclosed Warehouse Environment For Both Material Items Awaiting Repair And Assets Which Have Been Repaired And Are Awaiting Shipment To Ensure The Items Are Not Damaged While Being Stored. 4. Quality Assurance Provisions - Not Applicable. 5. Packaging- Mil-std 2073 Packaging Applies As Found Elsewhere In The Schedule 6. Notes - Not Applicable
Closing Date6 Jan 2025
Tender AmountRefer Documents 

MUNICIPALITY OF LANTAPAN Tender

Others
Philippines
Details: Description Republic Of The Philippines Province Of Bukidnon Municipality Of Lantapan Invitation To Bid For Procurement Of Office Supplies For All Offices Of Lgu-lantapan (1st Bid) 1. The Local Government Unit Of Lantapan, Through The General Fund Intends To Apply The Sum Of One Million Seven Hundred Twenty-one Thousand Seven Hundred Eight Pesos (php 1,721,708.00) Being The Abc To Payments Under The Contract Procurement Of Office Supplies For All Offices Of Lgu-lantapan Ib # 2024-12-079 Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. 2. The Local Government Unit Of Lantapan Now Invites Bids For The Above Procurement Project. Delivery Of The Goods Required Is 20 Calendar Days. Bidders Should Have Completed, From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii (instructions To Bidders). 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. Bidding Is Open To All Interested Bidders, Whether Local Or Foreign, Subject To The Conditions For Eligibility Provided In The 2016 Revised Irr Of Ra No. 9184. 4. Prospective Bidders May Obtain Further Information From The Local Government Unit Of Lantapan And Inspect The Bidding Documents At The Address Given Below During Mondays To Fridays From 8:00 A.m. To 5:00 P.m. 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On December 11, 2024 To January 2, 2025 From The Given Address And Website(s) Below And Upon Payment Of The Applicable Fee For The Bidding Documents, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Of Five Thousand Pesos (php 5,000.00). The Procuring Entity Shall Allow The Bidder To Present Personally Its Proof Of Payment For The Fees. [note: For Lot Procurement, The Maximum Fee For The Bidding Documents For Each Lot Shall Be Based On Its Abc, In Accordance With The Guidelines Issued By The Gppb; Provided That The Total Fees For The Bidding Documents Of All Lots Shall Not Exceed The Maximum Fee Prescribed In The Guidelines For The Sum Of The Abc Of All Lots.] 6. The Local Government Unit Of Lantapan Will Hold A Pre-bid Conference On December 17, 2024 At Municipal Conference Room Which Shall Be Open To Prospective Bidders. 7. Bids Must Be Duly Received By The Bac Secretariat Through Manual Submission At The Bac Office 2nd Floor, Municipal Conference Room, Municipal Hall, Poblacion, Lantapan, Bukidnon, On Or Before 8:45 A.m (philippine Standard Time) On January 2, 2025. Late Bids Shall Not Be Accepted. 8. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 14. 9. Bid Opening Shall Be On January 2, 2025 At 9:00 O’clock A.m At The Given Address Below. Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend The Activity. 10. [insert Such Other Necessary Information Deemed Relevant By The Procuring Entity Such As The Use Of A Back-up Data Or Cloud Storage For Large Files Uploaded For Online Bid Submissions] 11. The Local Government Unit Of Lantapan Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections 35.6 And 41 Of The 2016 Revised Irr Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 12. For Further Information, Please Refer To: Jefer Mae B. Macana Bac Secretariat Bac Office, 2/f Municipal Hall Purok 6, Poblacion, Lantapan Bukidnon, Philippines Email Add: Lant.bacsec2024@gmail.com 13. You May Visit The Following Website/s: Lantapan.gov.ph For Downloading Of Bidding Documents: Www.philgeps.gov.ph Date Of Issue: December 11, 2024 Engr. Jessell S. Pacturan, C.e. Bac Chairperson Reference No.: Ib # 2024-12-079 Name Of Project: Procurement Of Office Supplies For All Offices Of Lgu-lantapan Location Of Delivery: Lgu-lantapan, Bukidnon Abc: Php 1,721,708.00 Item No. Item Description Unit Of Issue Quantity Abc Unit Price Amount 1 Air Freshner Can 41 7,380.00 2 Albatross Pcs 81 3,240.00 3 Alcohol 500ml Bot 202 20,200.00 4 Alcohol Gal 17 9,350.00 5 A4tech Anti-glare Webcam Pk635g Pcs 1 3,000.00 6 Ballpen Pilot Black Pcs 322 11,270.00 7 Ballpen Pilot Blue Pcs 30 1,050.00 8 Ballpen Faber Castel Red Pcs 92 1,472.00 9 Ballpen Black Ordinary Pcs 591 5,910.00 10 Book Paper A4 Rms 455 109,200.00 11 Book Paper Short Rms 158 34,760.00 12 Book Paper Long Rms 688 172,000.00 13 Book Paper Long 80gsm Rms 5 1,400.00 14 Brown Envelope Long Pcs 959 6,713.00 15 Brown Envelope Short Pcs 311 1,866.00 16 Battery Double Aa Pack 42 3,570.00 17 Battery Triple Aaa Pack 25 2,125.00 18 Baygon Insect Killer Can 54 9,720.00 19 Book Paper Short 80 Gsm Rsms 5 1,250.00 20 Book Paper A4 80gsm Rms 25 6,500.00 21 Brother Ink Btd 60 Black Bot 63 25,200.00 Item No. Item Description Unit Of Issue Quantity Abc Unit Price Amount 22 Brother Ink 5000 Magenta Bot 32 12,800.00 23 Brother Ink 5000 Cyan Bot 32 12,800.00 24 Brother Ink 5000 Yellow Bot 32 12,800.00 25 Binder Clip Small Bx 99 3,465.00 26 Binder Clip Big Bx 96 5,760.00 27 Bath Soap Pc 4 160.00 28 Bar Soap (long Bar) Bar 30 1,200.00 29 Battery Rechargeable Double Aa Pc 5 1,250.00 30 Ballpen Fiber Castel Black Pc 529 8,464.00 31 Broom Stick Pc 29 1,015.00 32 Battery Eneloop Rechargeable Aa Pc 10 3,500.00 33 Ballpen Blue Pc 10 100.00 34 Battery 12v 5ah (for Ups) Pc 10 18,000.00 35 Columnar Notebook 12 Cols Pc 23 1,265.00 36 Cartolina Green Pc 12 120.00 37 Computer Mouse Wrieless Pc 9 3,150.00 38 Cannon Ink 810 Black Pc 4 8,600.00 39 Cannon Ink 811 Colored Pc 2 4,700.00 40 Clear Folder A4 Pc 26 416.00 41 Clear Folder Long Pc 136 2,448.00 42 Clear Folder Short Pc 32 512.00 43 Correction Tape Pcs 235 8,225.00 44 Correction Pen Pcs 16 1,760.00 45 Cartolina Pc 25 250.00 Item No. Item Description Unit Of Issue Quantity Abc Unit Price Amount 46 Computer Keyboard Usb Type Pc 16 5,600.00 47 Computer Mouse Usb Type Bot 17 5,100.00 48 Construction Paper Rm 8 2,800.00 49 Columnar Notebook 24 Cols. Pc 77 6,545.00 50 Cork Board Pc 7 5,320.00 51 Computer Mouse Pad Bot 11 1,650.00 52 Certificate Holder Short Pc 25 2,250.00 53 Certificate Holder Long Pc 44 4,400.00 54 Calculator Ordinary Bot 15 11,250.00 55 Calculator Scienttific Bot 1 1,250.00 56 Cutter Big Pc 13 585.00 57 Cutter Small Pc 3 75.00 58 Carbon Paper Plastofoil Long Black Pc 3 2,940.00 59 Continuos Paper Short 2 Ply Pc 24 54,000.00 60 Clear Envelope Long With Handle Pc 25 625.00 61 Cutter Blade Pc 1 25.00 62 Dtr Pc 12731 12,731.00 63 Dishawshing Liquid/paste Pc 112 6,720.00 64 Downy Bot 19 4,275.00 65 Dipper Big Pc 4 240.00 66 Data Filer Small With Cover Bot 2 700.00 67 Data Filer Big With Cover Pcs 215 81,700.00 68 Data Filer Big Without Cover Pc 25 7,500.00 69 Duct Tape Pc 39 2,730.00 Item No. Item Description Unit Of Issue Quantity Abc Unit Price Amount 70 Dust Pan Pc 17 1,105.00 71 Dishwashi Ng Sponge Pc 28 560.00 72 Double Sided Tape Roll 65 9,750.00 73 Data Folder Hard 76mmx230mmx380mm Pack 15 2,925.00 74 External Hard Drive 1tb Pc 5 12,500.00 75 Epson Ink 003 Black Pc 174 69,600.00 76 Epson Ink 003 Magenta Pc 79 31,600.00 77 Epson Ink 003 Cyan Pc 78 31,200.00 78 Epson Ink 003 Yellow Pc 78 31,200.00 79 Expanded Brown Envelope Long Pcs 816 14,688.00 80 Expanded Folder Long Pc 429 7,722.00 81 Electric Fan Pc 2 5,000.00 82 Elmers Glue 118 Ml Bot 45 2,520.00 83 Epson Ink T6641 Black Bot 49 19,600.00 84 Epson Ink T6642 Magenta Bot 17 6,800.00 85 Epson Ink T6643 Cyan Bit 17 6,800.00 86 Epson Ink T6644 Yellow Bot 22 8,800.00 87 Expanded Folder Long Yellow Pcs 350 6,300.00 88 Expanded Folder Long Blue Pcs 480 8,640.00 89 Folder Long Blue Pcs 30 210.00 90 Folder Long White Pcs 910 6,370.00 91 Folder Short White Pcs 81 486.00 92 Feather Duster Pc 16 1,040.00 93 Filing Tray 3 Layers Pc 8 6,000.00 Item No. Item Description Unit Of Issue Quantity Abc Unit Price Amount 94 Frame A4 Pcs 23 3,450.00 95 Ballpen Faber Castel Blue Pcs 15 240.00 96 Cotton Balls Pack 5 500.00 97 Glass Cleaner Bot 44 7,700.00 98 Halk White Enamel 100 Pcs /bx Bx 6 300.00 99 Garbage Basket Ordinary Big Pcs 18 4,500.00 100 Garbage Basket Pedal Type Pc 6 2,100.00 101 Garbage Bag Large Pack 4 600.00 102 Glass Window Wifer Pc 4 1,400.00 103 Gun Tucker Wire Arrow Jt21 Bx 4 720.00 104 Gun Tucker Jt21 Pc 3 6,750.00 105 Heavy Duty Cellophane With Handle Pc 200 7,000.00 106 Highlighter(stabilo Boss) Pc 164 7,380.00 107 Hp Ink 678 Black Pc 15 10,500.00 108 Hp Ink 678 Colored Pc 10 7,000.00 109 Hand Liquid Soap Pc 25 3,125.00 110 Hd-12n /24 Clincher Pc 1 2,000.00 111 Id Sling Pc 60 900.00 112 Id Jacket Pc 60 1,200.00 113 Index Tab Pc 14 3,500.00 114 Linen Paper Long Ordinary Pack 2 110.00 115 Linen Paper Short Ordinary Pack 135 7,020.00 116 Linen Paper Long Board Pc 11 660.00 117 Linen Paper Short Board Pc 355 19,525.00 Item No. Item Description Unit Of Issue Quantity Abc Unit Price Amount 118 Lysol Spray Pc 10 7,500.00 119 Linen Paper Short Blue Pack 10 520.00 120 Memeo Ppaer Long Pc 3 600.00 121 Memeo Paper Short Pc 2 360.00 122 Mop Head Pc 13 1,950.00 123 Mop Head With Handle Pc 23 8,050.00 124 Mounting Tape Roll 28 7,000.00 125 Masking Tape 1" Pc 31 1,860.00 126 ,masking Tape 2" Roll 49 3,430.00 127 Mannual Binding Machine Pc 1 5,000.00 128 Mailing Envelope Long White Bx 12 3,600.00 129 Manila Paper Pc 160 1,600.00 130 Muriatic Acid Gal 11 3,850.00 131 Notebook Pc 34 680.00 132 Official Record Book 500pp Pc 25 4,500.00 133 Paper Clip Small Bx 71 3,195.00 134 Paper Clip Jumbo Bx 76 3,800.00 135 Paper Fastener Plastic Pc 32 1,600.00 136 Paper Fastener Metal Bx 26 3,120.00 137 Pencil Pc 193 1,930.00 138 Paper Sharpener Small Gal 6 120.00 139 Post It Note Pad 744 33,480.00 140 Pentel Pen Fineblack Pc 87 4,350.00 141 Pentel Pen Black Broad Pc 82 4,100.00 Item No. Item Description Unit Of Issue Quantity Abc Unit Price Amount 142 Pentel Pen Blue Pc 5 250.00 143 Pentel Pen Red Pc 1 50.00 144 Pentel Pen Green Pc 5 250.00 145 Pail Big Pc 6 2,400.00 146 Push Pin Pack 33 1,155.00 147 Puncher Pc 14 2,520.00 148 Powder Soap Kls 99 14,850.00 149 Paper Cutter Big Pc 3 7,500.00 150 Photo Paper A4 Pad 65 6,500.00 151 Pvc Cover A4 Bx 1 990.00 152 Packaging Tape 2" Roll 13 975.00 153 Pledge Furniture Polisher Can 9 1,620.00 154 Paper Towel Interfold Pad 19 2,850.00 155 Pvc Cover Long Bx 1 1,100.00 156 Plastic Spiral Coil Binder Plastic Ring A4 32mm Pc 2 300.00 157 Plasric Spiral Coil Binder Plastic Ring A4 25mm Pc 2 400.00 158 Plastic Spiral Ring Long Bx 1 250.00 159 Plastic Spiral Ring Short Bx 1 250.00 160 Philippinea Flag 3 X 5 Pcs 50 20,000.00 161 Philippine Flag 4 X 8 Pcs 10 7,500.00 162 Rain Coat Single Whole Pc 2 1,200.00 163 Rubber Boots Pair 1 750.00 164 Rubber Eareser Bx 1 15.00 165 Ribbon Lq 310- Cartridge Pc 6 1,500.00 Item No. Item Description Unit Of Issue Quantity Abc Unit Price Amount 166 Ring Binder 1/4 Pc 3 180.00 167 Ring Binder 1/2 Pc 8 680.00 168 Ring Binder 1 Pc 6 600.00 169 Ring Binder 2 Pc 6 720.00 170 Rer Pad 10 500.00 171 Rug Pc 24 2,400.00 172 Ruler Pc 32 320.00 173 Record Book 300 Pp Pc 55 4,950.00 174 Record Book 500pp Pc 21 2,310.00 175 Rubber Band No. 18 Bx 3 1,050.00 176 Rubber Bnd Hd 350 Gsm Bx 5 2,000.00 177 Rice Cooker Pc 2 5,000.00 178 Rain Coat With Pants Set 3 4,500.00 179 Stamp-certified True Copy Pc 2 300.00 180 Stamp Released Pc 2 300.00 181 Stamp Received Pc 1 150.00 182 Sticker Paper A4 Pack 34 4,080.00 183 Scoth Tape 1' Roll 118 5,900.00 184 Scoth Tape 2' Roll 102 7,650.00 185 Scoth Brite Pc 44 2,640.00 186 Steel Wall Pc 5 300.00 187 Sign Pen Black Pc 900 27,000.00 188 Sign Pen Pilot Black Pc 56 8,400.00 189 Scissor Big Pcs 54 3,510.00 Item No. Item Description Unit Of Issue Quantity Abc Unit Price Amount 190 Soft Broom Pc 46 5,520.00 191 Staple Wire Hd-3ls 10mm Bx 14 1,680.00 192 Stapler With Remover Pc 39 17,940.00 193 Stamp Pad Inlk Purple Bx 33 1,485.00 194 Stamp Pad Ink Black Pc 8 360.00 195 Storage Box 50 Ltrs Pc 4 7,200.00 196 Spin Mop Pc 12 15,000.00 197 Spoon Doz 2 200.00 198 Sign Pen Black Uni Ball Impact Pc 211 33,760.00 199 Steel Map Pc 1 1,500.00 200 Stamp Pad Pc 15 900.00 201 Sign Pen Blue Pc 5 150.00 202 Stapler Swingline Big Hd Pc 4 3,000.00 203 Stick Glue Pc 46 460.00 204 Stapler Hd21-(23/17/120 Sheets) Pc 2 5,000.00 205 Staple Remover Pc 8 1,200.00 206 Staple Wire 35 Bx 135 6,075.00 207 Sign Pen Green Pc 6 180.00 208 Specialty Paper Vellum Board 180gsm Pack 50 3,250.00 209 Stapler Wioth Remover Hd Pc 9 4,140.00 210 Tissue Paper Doz 90 13,500.00 211 Thick Plastic Folder Long Pc 265 6,625.00 212 Tape Despenser Pc 9 1,620.00 213 Toilet Bowl Brush Pc 13 1,950.00 Item No. Item Description Unit Of Issue Quantity Abc Unit Price Amount 214 Tape Measure 100 Mtrs. Pc 1 600.00 215 Ups Pc 3 7,500.00 216 Usb 64 Gig Pc 3 2,400.00 217 Usb 8 Gig Pc 14 5,600.00 218 Usb 16 Gig Pc 7 3,500.00 219 Usb 32gig Pc 5 3,500.00 220 Whyte Board Pen Black Pc 39 1,950.00 221 White Board 4 X8 Pc 5 15,000.00 222 White Board Eareser Pc 7 455.00 223 Working Gloves Pair 3 450.00 224 Wet Wipes Pack 12 1,200.00 225 Wall Clock Pc 2 1,160.00 226 Yellow Pad Pad 8 320.00 227 Zonrox Gal 40 8,000.00 228 Coconut Scub Pcs 6 360.00 229 Dishwashing Liquid Bot 5 375.00 230 Floor Wax White Can 3 1,260.00 231 Zonrox Color Safe Gal 10 2,000.00 232 Table Shar Pener Pc 1 500.00 233 Toilet Pump Pc 6 780.00 234 Sliding Folder White Long Pc 60 1,500.00 235 Plastic Cellophe Cover Thick Mtrs 20 1,700.00 236 Linen Paper Short Light Blue Pack 20 1,200.00 237 Linen Paper Light Green Pack 65 3,900.00 Item No. Item Description Unit Of Issue Quantity Abc Unit Price Amount 238 Cloth Geena Earth Mint Green Mtrs 50 2,250.00 239 Medal Ordinary B-l-g Pcs 3000 90,000.00 Total Bid Price In Figure: Total Bid Price In Words: Prepared And Submitted By:
Closing Date2 Jan 2025
Tender AmountPHP 1.7 Million (USD 29.7 K)

DEPT OF THE NAVY USA Tender

Scraps
United States
Description: Contact Information|4|n743.49|wvm|7176052147|benjamin.t.spangler.civ@us.navy.mil| item Unique Identification And Valuation (jan 2023)|19|||||||||||||||||||| higher-level Contract Quality Requirement (navicp Review Feb 1991)(feb 1999)|1|see Specification Sections C And E.| inspection Of Supplies--fixed-price (aug 1996)|2||| time Of Delivery (june 1997)|20|0001aa|25|365|0001ab|lot|see Dd1423|0001ac|1|150|||||||||||| stop-work Order (aug 1989)|1|| general Information-fob-destination|1|b| wide Area Workflow Payment Instructions (jan 2023)|16|stand-alone Receiving Report - Certifications Combo - Receiving Report & Invoice - Material |n/a|tbd|n00104|tbd|n39040 - Certifications, S4306a - Material |n50286|tbd|133.2|n/a|n/a|n39040 - Certifications |n/a |n/a|see Dd Form 1423 |port_ptnh_wawf_notification@navy.mil Benjamin.t.spangler.civ@us.navy.mil| navy Use Of Abilityone Support Contractor - Release Of Offeror Information (3-18))|1|| value Engineering (jun 2020)|3|||| equal Opportunity (sep 2016)|2||| integrity Of Unit Prices (nov 2021)|1|| equal Opportunity For Veterans (jun 2020)|4||||| warranty Of Supplies Of A Noncomplex Nature (june 2003)|6|one Year From Date Of Delivery.|one Year From Date Of Delivery.||||| warranty Of Data--basic (mar 2014)|2||| small Business Subcontracting Plan (sep 2023)|4||||| equal Opportunity For Workers With Disabilities (jun 2020)|2||| transportation Of Supplies By Sea (oct 2024)|2||| first Article Approval--government Testing (sep 1989)|7|1|0001ac|150|receiving Officer Portsmouth Naval Shipyard, Building 240, Code 240. (207-438-5445) Kittery, Me 03904-5000|30|x|| buy American-free Trade Agreements-balance Of Payments Program-basic (feb 2024)|11|||||||||||| progress Payments (nov 2021)|4||||| list Of Award Attachments|5|||||| alternate A, Annual Representations And Certifications (oct 2024)|13|||||||||||||| buy American-free Trade Agreements-balance Of Payments Program Certificate-basic (feb 2024))|5|||||| buy American-balance Of Payments Program Certificate-basic (feb 2024)|1|| royalty Information (apr 1984)|1|| annual Representations And Certifications (may 2024)|13|335931|600|||||||||||| cost Accounting Standards Notices And Certification (deviation 2018-o0015)(may 2018))|1|| instructions To Offerors -- Competitive Acquisition (nov 2021)|2||| type Of Contract (apr 1984)|1|firm Fixed| notice Of Priority Rating For National Defense, Emergency Perpardeness, And Enrgy Progam Use (april 2008))|2|x|| evaluation Of First Article Testing|3|x|$42,000|| this Amendment Is Issued To Update Solicitation Clauses. this Requirement Is Not A Small Business Set-aside And Is Full And Open. \ ---this Requirement Is Not A Small Business Set-aside.--- 1.dd1423 Data Item A001 (inspection And Test Plan) May Be Waived If Already Onfile At Navsup Wss Mechanicsburg. 2. Portsmouth Nsy's Dodaac Has Changed From N00102 To N50286. Any Reference Ton00102 Within This Order Should Be Updated To N50286. 3. The Following Proposed Delivery Schedule Applies: submission Of Certification Data Cdrls Will Be On Or Before 20 Days Prior To Scheduled Delivery. weld Procedure And Qual Data 120 Days Adc Lt approval Of Weld Procedures And Qual Data 60 Days After Receipt fat Report 150 Days After Approval Of Pr Lt approval Of Fat Report 30 Days After Receipt Pnsy Review/acceptance Of Certification Cdrls 6 Working Days After Receipt Of Certification Dd 1423 Cdrls. Final Delivery Of Material Will Be On Or Before 365 Days After Effective Date Of The Resulting Contract. 4. Any Contract Awarded As A Result Of This Solicitation Will Be "dx" Rated Order; "dx" Rated Order Certified For National Defense Use Under The Defense Priorities And Allocations System (dpas). 5. Navsup Wss Mechanicsburg Will Be Considering Past Performance In The Evaluation Of Offers In Accordance With Far 13.106(a)(2) And Dfars 252.213-7000. 6. If Drawings Are Included In The Solicitation, Access Needs To Be Requested On The Individual Solicitation Page On Contracts Opportunities On The Government's Beta.sam Website. After Requesting Access, Send An Email To The Primary Poc Listed On The Solicitation. 7. This Solicitation Requires First Article Testing. Far 52.290-4 First Article Approval - Government Testing For More Details. 8. The Complete Rfp Package Must Be Signed And Returned Prior To The Closing Date. Emailed Or Faxed Proposals Are Acceptable. Neco Quotes Will Not Be Accepted And Will Be Determined Non-responsive. \ 1. Scope 1.1 The Material Covered In This Contract/purchase Order Will Be Used In A Crucial Shipboard System. The Use Of Incorrect Or Defective Material Would Create A High Probability Of Failure Resulting In Serious Personnel Injury, Loss Of Life, Loss Of Vital shipboard Systems, Or Loss Of The Ship Itself. Therefore, The Material Has Been Designated As Special Emphasis Material (level I, Scope Of Certification, Or Quality Assured) And Special Control Procedures Are Invoked To Ensure Receipt Of Correct Material. 2. Applicable Documents 2.1 Order Of Precedence - In The Event Of A Conflict Between The Text Of This Contract/purchase Order And The References And/or Drawings Cited Herein, The Text Of This Contract/purchase Order Must Take Precedence. Nothing In This Contract/purchase Order, however, Must Supersede Applicable Laws And Regulations Unless A Specific Exemption Has Been Obtained. 2.2 Applicable Documents - The Document(s) Listed Below Form A Part Of This Contract/purchase Order Including Modifications Or Exclusions. 2.2.1 Specification Revisions - The Specification Revisions Listed Under "documents References" Below Are The Preferred Revision. Older And/or Newer R Evisions Are Acceptable When Listed Within Contract Support Library Reference Number Csd155 In Ecds (electric contractor Data Submission) At: Ht Tps://register.nslc.navy.mil/. This Is To Allow Contractors To Use Certain Acceptable Older Specification Revisions To Purge Their Existing Stock Of Material Certified To Those Older Revisions Or To Use Newer Specification revisions When Material Is Certified To Newly Released Revisions,without Requiring The Submittal Of Waiver/deviation Requests For Each Specification Revision On Every Contract. Revisions Of Specifications Reflecting Editorial And/or Re-approval (e.g. E2009, r2014, Etc.) Are Considered Inconsequential, But Are Acceptable When Their Revisions Are Listedwithin Csd155 Or Elsewhere Within This Contract. 2.2.2 Documents, Drawings, And Publications Supplied Are Listed Under "drawing Number". These Items Should Be Retained Until An Award Is Made. 2.2.3 "document References" Listed Below Must Be Obtained By The Contractor. Ordering Information Is Included As An Attachment To This Contract/purchase Order. drawing Data=1197258 |53711| C| |d|0001 | C|49998|0876328 document Ref Data=fed-std-h28 | | |b |190424|a| | | document Ref Data=fed-std-h28 |0020| |b |941221|a| |01| document Ref Data=ansi/asq Z1.4 | | | |080101|a| | | document Ref Data=qq-n-281 | | |d |851023|a| 2| | document Ref Data=qq-n-286 | | |g |001207|a| | | document Ref Data=mil-std-792 | | |f |060519|a| | | document Ref Data=mil-dtl-1222 | | |j |001208|a| | | document Ref Data=mil-std-2035 | | |a |950515|a| | | document Ref Data=mil-std-2132 | | |d |080211|f| |01| document Ref Data=iso_9001 | | | |081115|a| | | document Ref Data=iso10012 | | | |030415|a| | | document Ref Data=iso/iec 17025 | | | |050515|a| | | document Ref Data=mil-dtl-24231 | | |e |130426|a| | | document Ref Data=mil-i-45208 | | |a |810724|a| 1| | document Ref Data=mil-std-45662 | | |a |880801|a| | | document Ref Data=a-a-59004 | | |b |181118|a| | | document Ref Data=ansi/ncsl Z540.3 | | | |130326|a| | | document Ref Data=0900-lp-001-7000 | | | |810101|c| |01| document Ref Data=s9074-aq-gib-010/248 | | |1 |191112|a| | | document Ref Data=t9074-as-gib-010/271 | | |1 |140911|a| | | document Ref Data=s9074-ar-gib-010a/278 (chg A) | | | |130214|a| | | 3. Requirements 3.1 ;the Electrical Hull Fitting And Transmitter Cable Assembly For The An/bst-1 Must Be In Accordance With Naval Ship Engineering Center Drawing 803-1197258, Except As Amplified Or Modified Herein.; 3.2 ;ls2swu-12 Cable Is To Be Used In Lieu Of Ls2swua-12 Cable.; 3.3 First Article Approval (government Testing) - First Article Test (fat) And Approval Is Required. 3.4 ;the First Article Test (fat) Sample(s) Must Not Be Delivered Against The Contract Quantity.; 3.5 Material For Parts Requiring Certification - Quantitative Chemical And Mechanical Analysis Is Required For The Parts Listed Below Unless Specifically Stated Otherwise: part - ;receptacle Body, Item 14; material - ;qq-n-281, Class A; part - ;hull Fitting Body, Item 2; Body Cover, Item 3; Washer, Item 4; And Nut, Item 5; material - ;qq-n-286, Form 2, Cold Drawn Or Hot Finished, Annealed And Age Hardened And Must Meet The Mechanical Requirements Cited In Note 2.h Of Drawing 803-1197258 Except The Brinell Hardness Minimum Is 250 Instead Of 265 As Listed In Note 2.h; 3.6 Testing Certification - Certifications Are Required For The Following Tests On The Items Listed Below. Additional Testing On Other Piece Parts (if Any) Per Applicable Drawings Is Still Required, But Certifications Are Only Required As Listed Below. test - Quality Conformance/compliance Inspection item - ;each Electrical Hull Fitting Assembly; performance - ;mil-dtl-24231, Table I For Type Iv And Note 22 On Drawing 803-1197258; acceptance - ;mil-dtl-24231; test - ;dye Penetrant Inspection; item - ;hull Fitting Body, Item 2; Body Cover, Item 3; Washer, Item 4; And Nut, Item 5; performance - T9074-as-gib-010/271 acceptance - Mil-std-2035 test - Ultrasonic Inspection On Starting Material item - ;all Items Requiring Certification Made From Qq-n-286 With A Diameter Or Minimum Distance Between Parallel Surfaces Of 4 Inches Or Greater Of The Starting Material, Or When Required By A Drawing Or Specification Invoked Elsewhere In This Contract; performance - T9074-as-gib-010/271 Or Mil-std-2132, And Qq-n-286 acceptance - Qq-n-286 attribute - Annealing And Age Hardening item - ;hull Fitting Body, Item 2; Body Cover, Item 3; Washer, Item 4; And Nut, Item 5; performance - Qq-n-286 test - 5x Visual Magnification Or Dye Penetrant Inspection (root Layer) item - Weldments performance - T9074-as-gib-010/271 acceptance - Mil-std-2035 test - Visual And Dye Penetrant Inspection (final Layer) item - Weldments performance - T9074-as-gib-010/271 acceptance - Mil-std-2035 test - Non-destructive Tests item - ;weld Repair (as Applicable); performance - Per Applicable Fabrication Specification acceptance - Per Applicable Fabrication Specification 3.7 The Pressure Tolerance Must Be As Specified In The Assembly Drawing, Detail Drawing, Design Specification Or Elsewhere In This Contract. Where Pressure Tolerances Are Not Provided By Drawings, Specifications Or Specified Elsewhere In This Contract, The following Must Be Used: For Pressure Tests Below 100 Psig, The Pressure Tolerance Must Be +1 Psig / -0 Psig. For Pressure Tests At Or Above 100 Psig Up To And Including 2500 Psig, The Pressure Tolerance Must Be +2% / -0 Psig Rounded Off To The Nearest Multiple Of The Smallest Graduation On An Analog Test Pressure Gauge, Not To Exceed 50 Psig. For Pressure Tests Above 2500 Psig, The Pressure Tolerance Must Be +2% / -0 Psig, Rounded Off To The Nearest Multiple Of The Smallest Graduation On An Analog Test Pressure Gauge, Not To Exceed 200 Psig. the Pressure Test Time Tolerance Must Be As Specified In The Assembly Drawing, Detail Drawing, Design Specification Or Elsewhere In This Contract. Where Pressure Test Time Tolerances Are Not Provided By Drawings, Specifications Or Specified Elsewhere In This contract, The Following Must Be Used: For A Test Duration Up To And Including 1 Hour, The Tolerance Must Be +5 Minutes / - 0 Minutes. For A Test Duration Of More Than 1 Hour Up To And Including 24 Hours, The Tolerance Must Be +30 Minutes / - 0 Minutes. For A Test Duration Of More Than 24 Hours, The Tolerance Must Be +60 Minutes / - 0 Minutes. 3.8 Slow Strain Rate Tensile Test Laboratories - The Slow Strain Rate Tensile Test Of Qq-n-286 Must Be Performed By One Of The Following Laboratories: huntington Alloys, A Special Metals Company attn: Bill Bolenr 3200 Riverside Drive huntington, Wv 257059 phone: (304) 526-5889 fax: (304) 526-5973 metallurgical Consultants, Inc. attn: W. M. Buehler 4820 Caroline po Box 88046 houston, Tx 77288-0046 phone: (713) 526-6351 fax: (713) 526-2964 naval Surface Warfare Center, Carderock Division attn: Eric Focht Code 614 9500 Macarthur Blvd west Bethesda, Md 20817-5700 phone: (301) 227-5032 fax: (301) 227-5576 teledyne Allvac attn: Dr. W. D. Cao 2020 Ashcraft Ave. monroe, Nc 28110 phone: (704) 289-4511 fax: (704) 289-4269 westmoreland Mechanical Testing And Research Inc. attn: Andrew Wisniewski p.o. Box 388 youngstown, Pa 15696-0388 mannesmann Rohrenwerke mannesmann Forschungsinstitut (mfi) attn: Dr. Weiss postfach 251160 47251 Duisburg germany phone: 011-49-0203-9993194 fax: 011-49-0203-9994415 thyssenkrupp Vdm Usa, Inc. attn: D. C. Agarwal 11210 Steeplecrest Drive, Suite 120 houston, Tx 77065-4939 phone: (281) 955-6683 3.9 Certificate Of Compliance - (special Emphasis Material) The Contractor Must Prepare And Submit A Certificate Of Compliance Certifying That The Items/components Furnished Under This Contract Comply With The Requirements Of The Procurement Document, including Any/all Invoked Specifications And Drawings. 3.10 Thread Inspection Requirements - All Threads On Threaded Parts Must Be Inspected Using Appropriate Inspection Methods, Inspection Systems, And Inspection Gages/instruments In Accordance With Fed-std-h28 Series. Substitution Of Thecommercial Equivalent inspection In Accordance With Asme B1 Series Is Acceptable. 3.10.1 System 21 Of Fed-std-h28/20 Must Be Used As A Minimum Inspection Requirement For Threads When The Design Drawing Or Design Specification Does Not Specify An Inspection Requirement. 3.10.2 For Navy And Shipyard Drawings, System 21 Of Fed-std-h28/20 May Be Substituted For System 22 Without Further Navy Approval When The Design Drawing Invokes System 22 And Does Not Cite Governing Specifications That Specifically Require System 22. System 22 Of Fed-std-h28/20 Must Be Used When The Drawing References Other Governing Specifications That Specifically Require System 22, Such As Certain Thread Types Of Mil-dtl-1222. 3.10.3 A Written Request For Concurrence Must Be Submitted When Utilizing Alternative Measuring Equipment Or Measuring Systems Not Applicable To The Specified Inspection System. 3.11 Thread Lubricant - Thread Lubricants Containing Molybdenum Disulfide Must Not Be Used On This Material. Bacteria In Water, Especially Seawater, Causes Molybdenum Disulfide To Break Down. The By-products Of The Breakdown Form Compounds Which Attack The fasteners. Anti-galling Compound A-a-59004 Must Be Used As A Replacement When Thread Lubricant Is Required For Assembly. 3.12 Internal Threads - All Internal Threads Must Be Formed By Cutting. Cold Forming Of Internal Threads Is Not Acceptable. 3.13 O-ring Grooves And Mating Sealing Surfaces Must Be Inspected Per The Contractually Invoked Drawings Or Specifications. When The Drawings Or Specifications Do Not Provide Specific Defect Criteria Or State That No Defects Are Allowed, The General acceptance Criteria (gac) Standard Must Be Used For Inspecting O-ring Grooves And Mating Sealing Surfaces Only. Repairs To Sealing Surfaces And O-ring Grooves With Unacceptable Defects May Be Accomplished Within The Limits Of The Size And Tolerances Provided in The Applicable Drawing. Repairs Thatwould Exceed These Limits Require Approval (including Final Dimensions). The Data That Is Red Lined (crossed Out) Is Excluded From The Gac For This Contract And Is Not To Be Used For Acceptance Or Rejection Criteria. the Gac Document Is Identified As Contract Support Library Reference Number Csd008 At Https://register.nslc.navy.mil/ 3.14 Welding Or Brazing - When Welding, Brazing, And Allied Processes Are Required, As Invoked By Section C Paragraph 3 Requirements, They Must Be In Accordance With S9074-ar-gib-010a/278, 0900-lp-001-7000 For Brazing Of Piping And Pressure Vessel applications, Or S9074-aq-gib-010/248 For Brazing Of Other Applications. For All Production And Repair Welding And Brazing, Personnel And Procedures Must Be Qualified Under S9074-aq-gib-010/248 Or 0900-lp-001-7000, As Applicable. Repair Welding Is Not permitted On ;qq-n-286 Material; . Procedures And Qualification Data Must Be Submitted For Review And Approval Prior To Performing Any Welding Or Brazing. 3.15 Configuration Control - The Contractor Must Maintain The Total Equipment Baseline Configuration. For Items Of Proprietary Design, Contractor Drawings Showing The Latest Assembly Configuration Must Be Provided To The Government In Electronic (c4) Format. definitions Are Provided Elsewhere In The Contract/purchase Order. 3.15.1 Waivers/deviations - All Waivers And Deviations, Regardless Of Significance Or Classification Require Review And Approval By The Contracting Officer. Waivers And Deviations Must Be Designated As Critical, Major, Or Minor. The Contractor Must Provide a Copy Of This Request To The Qar. Requests Must Include The Information Listed Below. A. A Complete Description Of The Contract Requirement Affected And The Nature Of The Waiver/deviation (non-conformance), Including A Classification Of Critical, Major, Or Minor. B. Number Of Units (and Serial/lot Numbers) To Be Delivered In This Configuration. C. Any Impacts To Logistics Support Elements (such As Software, Manuals, Spares, Tools, And Similar) Being Utilized By Government Personnel Or Impacts To The Operational Use Of The Product. D. Information About Remedial Action Being Taken To Prevent Reoccurrence Of The Non-conformance. 3.15.2 All Requests For Waivers/deviations On Navsup-wss Contracts Must Be Submitted To The Navsup Wss Contracting Specialist Via Email. 3.15.3 Ecps - The Government Will Maintain Configuration Control And Change Authority For All Modifications Or Changes Affecting Form, Fit, Function, Or Interface Parameters Of The Equipment And Its Sub-assemblies. The Contractor Must Submit An Engineering change Proposal (ecp) For Any Class I Or Ii Changes That Impact The Equipment Covered By This Contract. Ecps Must Be Prepared In Contractor Format, And Must Include The Following Information: A. The Change Priority, Change Classification (class I Or Class Ii), And Change Justification. B. A Complete Description Of The Change To Be Made And The Need For That Change. C. A Complete Listing Of Other Configuration Items Impacted By The Proposed Change And A Description Of The Impact On Those Cis. D. Proposed Changes To Documents Controlled By The Government. E. Proposed Serial/lot Number Effectivities Of Units To Be Produced In, Or Retrofitted To, The Proposed Configuration. F. Recommendations About The Way A Retrofit Should Be Accomplished. G. Impacts To Any Logistics Support Elements (such As Software, Manuals, Spares, Tools, And Similar) Being Utilized By Government Personnel In Support Of The Product. H. Impacts To The Operational Use Of The Product. I. Complete Estimated Life-cycle Cost Impact Of The Proposed Change. J. Milestones Relating To The Processing And Implementation Of The Engineering Change. 3.16 Mercury Free - Mercury And Mercury Containing Compounds Must Not Be Intentionally Added Or Come In Direct Contact With Hardware Or Supplies Furnished Under This Contract. Mercury Contamination Of The Material Will Be Cause For Rejection. 3.17 Navsea 0948-lp-045-7010 - Any Applicable Requirements Of Navships 4410.17,navsea 0948-lp-045-7010, Or 0948-045-7010 Which The Contractor Must Meet Are Included In This Contract/purchase Order. The Above Documents Are For Governmentuse Only. Further application Of The Above Documents Is Prohibited.prohibited. 3.17.1 Marking Of Material With A Material Designator Per The Drawing Is Also Prohibited, With The Exception Of Fasteners. Fasteners Must Be Marked With A Material Symbol/designator As Specified Elsewhere In This Contract. ^ Quality Assurance Requirements ^ 3.18 See Cdrl Di-misc-80678 (test Certification) - A Statement Of Tests Performed, Listing The Pieces Tested Must Be Furnished Along With A Copy Of The Test Results. Certification Must Include The Contractor's Name, Address And Date, Quantity Inspected, identified To The Contract/purchase Order And Item Number, And The Contractor's Or Authorized Personnel's Signature. Test Certifications Must Reference The Standard/specification, Including The Revision, To Which The Testing Was Performed And The Acceptance criteria Used. Test Procedure Numbers May Also Be Referenced On Test Reports. Test Reports On Weldments Must Be Identified To Weld Joint And Layer. 3.19 See Cdrls Di-misc-80875 (welding Procedures) And Di-misc-80876 (weld Procedure Qualification Data) - When Production Or Repair Welding Is Required, The Applicable Welding Procedure(s) And Qualification Data Must Be Submitted For Review And Approval. In addition, The Consumed Weld Metal C Of C As Defined Below Must Be Submitted As Part Of The Certification Oqe Package Submitted By The Contractor. note: These Requirements Do Not Apply To Tack/spot Welds. 3.19.1 Approval Of The Contractor's Qualification Data Must Be Obtained Prior To Performing Any Welding (production Or Repair). 3.19.2 If The Contractors Qualification Data Has Previously Been Approved By The Navy For Other Contracts, A Copy Of The Original Approval Letter May Be Submitted Along With The Procedures And Qualification Data Report To Expedite The Approval Process. The approval Letter Must Reference The Applicable Welding Procedure And Qualification Data Report Identification/number. Prior Approval Does Not Guarantee Acceptance For This Or Any Future Contracts. As Far As Practical, All Procedures For The Contract Must Be submitted At The Same Time. Welding Procedures And Qualification Data Must Be Submitted In A Commercially Available Electronic Format Such As Adobe Acrobat Pdf. The Contractor Must State The Applicability Of Each Weld Procedure And Qualification Data Submitted, citing The Drawing Number And Pieces To Be Welded. (i.e. "wp-123 And Qd-123 Are Submitted For The Weld Joint Between Pieces 1 And 2 On Drawing Abc." Wp-456 And Qd-456 Are Submitted For The Hardfacing Of Piece 3 On Drawing Xyz.") 3.19.3 The Pco's Authorization For The Use Of Weld Procedure(s) And Qualification Data For The Specific Application As Submitted Does Not Mitigate The Vendors Responsibility To Comply With The Requirements Of S9074-aq-gib-010/248, S9074-ar-gib-010a/278, And the Contract. 3.19.4 Authority For The Repair Of Special Repairs In Castings, The Repair Of Wrought Material, Or The Repair Of Forged Material Must Be Obtained Via Request For Waiver From The Procurement Contracting Officer. This Request Must Describe The Defect; Including size, Depth, Location, And A Description Of The Proposed Repair. Repairs Deemed Minor Or Nominal In Accordance With S9074-ar-gib-010/278 Can Be Made At Contractor Discretion In Accordance With S9074-ar-gib-010/278 Requirements; However, Weld Procedure specification (wps) And Procedure Qualification Record (pqr) Submittals Are Still Required. This Request For Navsup-wss Contracts Must Be Submitted Via The Electronic Contractor Data Submission (ecds) Application. 3.19.5 Any New Procedure Qualification Performed Under This Contract Will Require The Vendor To Provide A Minimum 72 Hour Notification To Dcma With An Offer To Observe The Welding Of The Test Assemblies. The 72 Hour Time Limit May Be Modified Upon Mutual agreement Between The Vendor And Dcma. 3.19.6 When Drawings Require Hardfacing Surface Iron Or Nickel Content Not To Exceed 5%, The Contractor Must Verify Surface Iron Or Nickel Content By Performing Chemical Testing As Defined By The Applicable Drawing. The Chemical Test Results Must Be Submitted as Part Of The Qualification Data. 3.19.7 Additional Qualification Requirements For Production Hardfacing Thickness Less Than 1/8-inch: Macro-etch (or Legible Photomacrographs Clearly Showing The Fusion Area) Must Be Submitted For Review And Show Consistent, Minimized Dilution. All Essential elements And Any Elements Not Listed In S9074-aq-gib-010/248 That Influence Dilution Must Be In The Qualification Data And Weld Procedure, With Strict Limits Placed On Each Essential Element. 3.19.8 Preparation And Retention Of Weld Records Is Required, As Specified By Paragraph 4.1.3 Of S9074-ar-gib-010a/278. 3.19.9 When Production Or Repair Welding Is Required On Titanium Materials, The Applicable Fabrication Plan, Facilities Procedure, Training Plan, And Active Welder Qualification Must Also Be Submitted For Review And Approval. 3.19.10 If The Contractor's Fabrication Plan, Facilities Procedure, Training Plan, Or Active Welder Qualification Has Previously Been Approved By The Navy For Other Contracts, A Copy Of The Original Approval Letter May Be Submitted Along With The Applicable documentation To Expedite The Approval Process. The Approval Letter Must Reference The Applicable Documentation. Prior Approval Does Not Guarantee Acceptance For This Or Any Future Contracts. The Contractor's Fabrication Plan, Facilities Procedure, Training plan, And Active Welder Qualification Must Be Submitted At The Same Time As The Applicable Welding Procedure(s) And Weld Procedure Qualification Data. All Documentation Must Be Submitted In A Commercially Available Electronic Format, Such As Adobe Acrobat Pdf. 3.19.11 See Cdrl Di-misc-80678 (consumed Weld Metal) - A Certificate Of Compliance Is Required For All Weld Filler Metals Used For Production Or Repair Welding, And Must Include The Following: a) Filler Metal Lot Number(s) b) Specification And Type c) A Positive Statement That The Vendor Has Obtained Oqe And Verified That Each Lot Of Weld Filler Material Conforms To Specification Requirements. d) A Positive Statement Verifying That The Weld Filler Metals Were The Correct Material Type Or Grade Prior To Consumption. 3.19.12 When Production Welds Or Repair Welds Are Performed By A Subcontractor, The Requirement For Submission Of All Certification Documentation Required Herein Must Be Passed Down To The Subcontractor. 3.20 First Article Test/inspection (government) - ;destructive; - The Contractor Shall Deliver ;one (1); Unit(s) To ;receiving Officer Portsmouth Naval Shipyard, Building 240, Code 240. (207-438-5445) Kittery, Me 03904-5000; For First Article Tests In Accordance With The ;requirements Of Mil-dtl-24231, Table I For Type Iv And Note 21 On Drawing 803-1197258; . 3.21 Quality System Requirements - The Contractor Furnishing Items Under This Contract/purchase Order Must Provide And Maintain A Quality System In Accordance With Iso-9001 As Amplified Or Modified Herein, With The Calibration System Requirements Of Iso-10012 or Ansi-z540.3 With Iso-17025. A Quality System In Accordance With Mil-i-45208, With The Calibration System Requirements Of Mil-std-45662, Is Acceptable As An Alternate. 3.21.1 The Contractor's Quality System And Products Supplied Under The System Are Subject To Evaluation, Verification Inspection, And Acceptance/nonacceptance By The Government Representative To Determine The System's Effectiveness In Meeting The Quality requirements Established In The Contract/purchase Order. 3.21.2 The Contractor's Quality System Must Be Documented And Must Be Available For Review By The Contracting Officer Or His Representative Prior To Initiation Of Production And Throughout The Life Of The Contract. The Prime Contractor Must, Upon notification, Make His Facilities Available For Audit By The Contracting Officer Or His Authorized Representative. 3.21.3 See Cdrl Di-qcic-81110 (inspection System Procedures) - All Suppliers Of Level I/subsafe (li/ss) Material Are Required To Submit A Copy Of Their Current Documented Quality System Procedures To The Procurement Contracting Officer (pco) Prior To Award Of any Contract/purchase Order. Suppliers That Have A Copy Of Their Current Quality System Procedures On File At The Procuring Activity May Request The Pco Waive This Requirement. 3.21.4 This Contract Provides For The Performance Of Government Quality Assurance At Source. The Place Or Places Of Performance May Not Be Changed Without The Authorization Of The Procurement Contracting Officer. Upon Receipt Of This Order, Promptly notify The Government Representative Who Normally Services Your Plant So That Appropriate Planning For Government Inspection Can Be Accomplished. If You Do Not Have An Assigned Government Representative, Notify The Nearest Defense Contract Management Agency (dcma) Office. In The Event That A Local Government Representative Or Dcma Office Cannot Be Located, Our Purchasing Agent Should Be Notified Immediately. 3.21.5 Any Changes Made By The Contractor To A Qualified Quality System Will Require Re-submittal To The Pco And Concurrence By The Government Quality Assurance Representative Prior To Adoption. 3.22 Contractor Inspection Requirements - The Contractor Must Maintain Adequate Records Of All Inspections And Tests. The Records Must Indicate The Nature And Number Of Observations Made, The Number And Type Of Deficiencies Found, The Quantities Approved And rejected And The Nature Of Corrective Action Taken As Appropriate. Inspection Records Must Be Traceable To The Material Inspected. 3.22.1 The Supplier's Gages, Measuring And Test Equipment Must Be Made Available For Use By The Government Representative When Required To Determine Conformance With Contract Requirements. When Conditions Warrant, The Supplier's Personnel Must Be Made available For Operations Of Such Devices And For Verification Of Their Accuracy And Condition. 3.22.2 All Documents And Reference Data Applicable To This Contract Must Be Available For Review By The Government Representative. Copies Of Documents Required For Government Inspection Purposes Must Be Furnished In Accordance With The Instructions Provided by The Government Representative. 3.23 Subcontractor Inspection Requirements - The Government Has The Right To Inspect At Source, Any Supplies Or Services That Were Not Manufactured Or Performed Within The Contractor's Facility. Such Inspection Can Only Be Requested By Or Under Authorization of The Government Representative. Any Purchasing Documents To A Subcontractor Must Cite The Applicable Portions Of The Contractually Invoked Quality System (e.g. Calibration Requirements), Plus Any Product Requirements That Apply To The Supplies Being purchased. When The Government Elects To Perform Source Inspection At The Subcontractor's Facility, Applicable Purchase Documents Must Be Annotated With The Following Statement: "a Government Inspection Is Required Prior To Shipment From Your Plant. Upon receipt Of This Order, Promptly Notify The Government Representative Who Normally Services Your Plant So That Appropriate Planning For Government Inspection Can Be Accomplished. If You Do Not Have An Assigned Government Representative, Notify The Nearest defense Contract Management Agency (dcma) Office. In The Event That A Local Government Representative Or Dcma Office Cannot Be Located, Our Purchasing Agent Should Be Notified Immediately." 3.23.1 The Prime Contractor's Program Must Include Procedures To Assess The Capability Of The Prospective Suppliers To Produce The Products Or Supply The Services In Accordance With The Contract, Prior To The Issuance Of Any Purchase Document. 3.23.2 Each Sub-tier Supplier Of Material Or Services For Items In Section 3 Of This Contract Must Be Subjected To A Periodic Review Or Audit By The Prime To Determine The Continued Capability Of The Supplier To Control The Quality Of The Products Or Services specified In The Purchase Order Or Contract. 3.23.3 The Prime Contractor Must Ensure That The Purchased Product Conformsto Specified Purchase Requirements And This Contract. The Type And Extent Of Control Applied To The Supplier And The Purchased Product Must Be Dependent Upon The Effect Of The purchased Product On The End Item Represented By This Contract. 3.23.4 The Prime Contractor Must Evaluate The Requirements Of The Contractand Select Suppliers Based On Their Ability To Supply The Product In Accordance With The Prime Contractor's Requirements And The Contract. Criteria For Selection And Evaluation Must Be established. Records Of This Effort Must Be Available For Review By The Government. 3.23.5 The Prime Contractor's Supplier Quality Assurance Program Must Provide For A Review Of Purchase Documents To Assure Applicable Quality Requirements Are Included Or Referenced In The Documentation For Compliance By The Supplier. 3.24 Government Furnished Material And/or Equipment (gfm/gfe) - When Material Or Equipment Is Furnished By The Government, The Contractor Must Develop Documented Control Procedures That Require At Least The Following: 3.24.1 Visual Examination Upon Receipt To Detect Damage During Transit. 3.24.2 Inspection For Completeness And Proper Type. 3.24.3 Verification Of Material Quality Received. 3.24.4 Periodic Inspection And Precautions To Assure Adequate Storage Conditions And To Guard Against Damage From Handling And Deterioration During Storage. 3.24.5 Functional Testing, Either Prior To Or After Installation, Or Both, As Required By The Contract To Determine Satisfactory Operation. 3.24.6 Identification And Protection From Improper Use Or Disposition. 3.24.7 Reporting To The Government, Any Gfm Or Gfe Property Found Damaged, Malfunctioning, Or Otherwise Unsuitable For Use. In The Event Of Damage Or Malfunction During Or After Installation, The Supplier Must Determine And Record Probable Cause And necessity For Withholding The Material From Use. 3.24.8 For Gfe Material, And As Required By The Terms Of The Bailment Agreement, The Supplier Must Establish Procedures For Adequate Storage, Maintenance, And Inspection Of Bailed Government Material. Records Of All Inspection And Maintenance Performed On bailed Property Must Be Maintained. 3.24.9 Material Returned To The Contractor Must Be Handled As Gfm. 3.25 Traceability And Certification Requirements - To Assure That Correct Materials Are Installed In Level I/subsafe Systems, It Is Imperative That Traceability Be Maintained From The Material To The Material Certification Test Report And Other Required objective Quality Evidence (oqe). The Material Certification Report Must Completely And Accurately Reflect That The Material Supplied Meets The Specified Requirements. Materials Requiring Traceability And Certification Data Are Identified Within Paragraph 3, section C Of This Contract/purchase Order. 3.25.1 The Following Provides The Minimum Requirements For Maintaining Material Traceability And Supplements The Requirements Specified In Di-misc-81020 And Elsewhere In The Contract/purchase Order. The Contractor Must Develop Written Procedures That implement The Material Control Requirements Stated Herein And Elsewhere In This Contract/purchase Order. 3.26 Material Traceability - The Certification Data Report Must Be Identified Through A Unique Traceability Number, Heat-lot Number, Or Heat-treat Number, As Applicable, Which Must Also Be Marked On The Material. This Traceability Marking On The Material Must provide Direct Traceability To The Material's Chemical Composition And Mechanical Properties Certification Data. For Material Produced By Batch, Continuous Cast, Or Continuous Pour Processes, Samples Must Be Taken No Less Than Once In Every Eight Hours Of operation For The Purpose Of Validating Proper Chemical Composition And Mechanical Properties. Traceability Must Be Maintained Through All Process Operations Including Any Subcontracted Operations, To The Finished Component. 3.26.1 Material Marking For Traceability And Identification - The Following Are The Minimum Marking Requirements. Additional/alternate Marking Requirements, If Applicable, Will Be Specified Elsewhere In The Contract/purchase Order. In Addition To The marking Requirements On Applicable Drawings And/or Specifications, Marking For Traceability Is Required. All Traceability Markings Must Be Permanently Applied In Accordance With Mil-std-792 (except As Specified Below). An Alternate Marking Method Is permissible Provided It Is An Available Option In The Contractually Invoked Specification Or Drawing, Except In Instances Where The Material Has Been Modified By This Contract/purchase Order And Differs From That Specified In The Specification Or Drawing. 3.26.2 Traceability Markings For Items With Precision Machined Or Plated Surfaces, Or Material With Suitable Marking Surface Areas Less Than 3/8 Inches Square (either 3/8" X 3/8" Or An Area Equal To 0.1406 Inches Square) Must Be Applied To A Durable Tag And the Tag Securely Affixed To The Material. 3.26.3 Traceability Markings Must Be Maintained Through Assembly, And Whenever Possible Must Be Visible After Assembly. For Items Where The Marking Is Not Visible After Assembly, A Durable Tag Must Be Securely Attached To The Assembly Identifying The Part number, Piece Number, Traceability Number, And The Location Of The Permanent Mark. 3.26.4 Marking Must Be Legible And Must Be Located So As To Not Affect The Form, Fit, And Function Of The Material. ; ; 3.27 See Cdrl Di-misc-81020 (chemical And Mechanical) - Material Certification - In Addition To The Certification Data Requirements Specified In Di-misc-81020, The Following Material Certification Requirements Apply: 3.27.1 Quantitative Chemical And Mechanical Analysis Of Material Traceable To Traceability Markings Is Required. Material Certification Test Reports Must Include The Class, Form, Condition, Grade, Type, Finish, And/or Composition, As Applicable, Of The material Supplied. 3.27.2 Re-identification And Re-certification Of Material Is Required When The Material Is Subjected To A Process Which Alters It's Properties. If The Starting Material Or Raw Stock Is Processed In A Manner That Will Not Affect Its Chemical Composition Or mechanical Properties, The Original Certifications For The Chemical Composition And Mechanical Properties, As Required By The Material Specification, Are Acceptable. Re-certification Of The Chemical Or Mechanical Properties Is Required If A Process Is Used during Fabrication That Alters The Original Properties Of The Material (e.g. Alloying, Heat Treating, Or Forming). In These Instances, The Properties Of The Material Must Be Re-determined And Documented To Reflect The Altered Condition. The Altered Material must Be Uniquely Re-identified. The Properties Thus Determined And Documented, Are Required For Final Certification And Must Conform To The Material Specification Or The Contract/purchase Order Requirements. When Only The Mechanical Properties Are Altered, the Original Certification Forchemical Composition Must Be Overstamped And Annotated With The Unique Traceability Material And At A Minimum Contain The Information Below. traceability Marking ________________________________________________ (marking On Finished Item) is Fabricated From Raw Material Identified To heat/lot Number ______________ And Heat Treat Number _____________________ (when Applicable) _________________________________________ Date _____________________ (name And Signature Of Auth. Co. Rep.) 3.27.3 Material Certification Data Forwarded By The Manufacturer Must Contain A Signed Certification That The Report Results Represent The Actual Attributes Of The Material Furnished And Indicate Full Compliance With All Applicable Specification And Contract requirements. Transcription Of Certification Data Is Prohibited. 3.27.4 Statements On Material Certification Documents Must Be Positive And Unqualified. Disclaimers Such As "to The Best Of Our Knowledge" Or "we Believe The Information Contained Herein Is True" Are Not Acceptable. 3.27.5 If Material Is Received Without The Required Certification Papers Or With Incorrect/missing Data On The Certification Papers, The Material Will Be Rejected. 3.28 Material Handling - The Written Material Control Process Must Include The Following: 3.28.1 All Raw Materials Must Have Traceability Markings (except As Specified Below). 3.28.2 Stored Raw Materials Requiring Traceability Must Be Segregated To Preclude Intermingling With Materials Not Requiring Traceability. 3.28.3 When Traceability Markings Will Be Removed By A Manufacturing Or Fabrication Process, The Marking Must Be Recorded Prior To Removal And Be Immediately Restored Upon Completion Of The Process. If This Cannot Be Done Or Is Impractical, An Appropriate material Control Procedure (such As A Bag And Tag, Tagging, And/or Tote Box Control) Must Be Employed. The Material Control Procedure Must Provide A Method Of Positive Control To Preclude Commingling Of Heats/lots Or Loss Of Traceability. The Traceability marking Must Be Reapplied Upon Completion Of The Final Manufacturing Process. 3.28.4 Brazing Or Weld Filler Metals For Strength Welds Forming Or Integral With Pressure Containing Components Or Assemblies Requiring Traceability Must Be Verified To Be The Correct Material, And Type Or Grade, As Applicable, Prior To Consumption. At A minimum, Material Verification Must Consist Of Inspection Of Material Test Reports For Conformance To Specified Requirements. Control Of Welding And Brazing Filler Metals Must Be Maintained To The Point Of Consumption To Assure Use Of The Correct Type And grade. Markings And Traceability Requirements Do Not Apply To Brazing And Weld Filler Metals After Consumption. It Is The Responsibility Of The Prime Contractor To Ensure Conformance With The Above Requirements On Welds Performed By Their Subcontractors. 3.28.5 Purchase Orders For Raw Material Must Specify That The Material Be Traceable To Material Certification Test Reports By Traceability Markings On The Material And Identified On The Test Reports. The Certification Data Requirements Contained In di-misc-81020 Must Be Invoked By The Prime Contractor On All Subcontractors Supplying Level I Material. 3.28.6 The Material Control Process Must Include Requirements For The Maintenance Of Traceability For Items Sent Out For Subcontracted Operations. If Such Operations Would Remove Traceability Markings, Purchase Or Work Orders Must Specify A Method And Marking location For Remarking. The Contractor Must Also Ensure That Subcontractor Production Controls Are Adequate To Preclude Commingling Of Materials During Processing. 3.29 Receiving Inspection - 3.29.1 Products And Services Produced By Sub-tier Suppliers For Incorporation In The Contract End Item Must Be Subject To Inspection Or Audit At The Time Of Receipt By The Prime Prior To Further Processing Within The Prime Contractor's Plant Or Shipment To another Location. 3.29.2 Receiving Inspection Must Include As A Minimum - verification That The Traceability Marking On The Material Agrees With That On The Certification Test Reports. verification That Certification Test Reports Are Legible And Complete. verification That The Contents Of The Certification Test Reports Are In Compliance With The Contractually Invoked Specifications And Requirements. 3.30 Discrepancy Reporting - 3.30.1 Nonconforming Products From Sub-tier Suppliers Must Be Identified And Processed In Accordance With The Prime Contractor's Procedures For Controlling Nonconforming Products. The Prime Contractor Must Report The Receipt Of Any Nonconforming Products To the Responsible Sub-tier Supplier In Accordance With Established Procedures. Nonconforming Material Records Must Be Maintained And Available For Review By The Government Quality Assurance Representative (qar). 3.31 Final Inspection - The Following Inspections Must Be Performed Prior To Government Inspection And Acceptance. 3.31.1 Material Sampling - Material Must Be Inspected For Form, Fit, And Function. Lot Acceptance Must Be Based On Zero Defects And Lot Rejection Based On One Defect. The Sample Size Must Be In Accordance With The Sampling Plan(s) In The Applicable Military specification Or Standard, Federal Specification Or Standard, Or Drawing To Which The Material Was Manufactured. In The Absence Of Such Sampling Plans, Sampling Inspection Must Be Per Ansi/asq-z1.4, General Inspection Level Ii (for Sample Size Selection Code), table Iia (for Sample Size). small Lot Sizes - For Lot Sizes Of Fifty Or Less, The Minimum Sample Size Must Be Eight Units. For Lot Sizes Of Eight Or Less, The Sample Size Must Be One Hundred Percent Of The Lot. 3.31.2 The Manufacturer May Elect To Use Statistical Process Control (spc) To Assure Product Quality In Lieu Of The Above Attribute Sampling Plan, Provided That The Spc Methodology/system Used Provides Acceptable Products To The Government. However, The government/navy Receipt Inspection Activity May Perform Their Acceptance Inspection Of The Material Using The Attribute Sampling Plan Outlined Above. 3.31.3 All Data Concerning Material Verification (chemical, Mechanical Or Physical Properties), Traceability (material Certifications To Material Marking), And Nondestructive Test (ndt) Certifications For Material Must Be 100% Inspected. The Certification test Reports Must Also Be 100% Inspected For Completeness And Legibility. 3.31.4 All Material Requiring Traceability Must Be 100% Inspected For Traceability Marking And That The Marking Is Legible. 3.32 See Cdrl Di-misc-80678 (special Emphasis C Of C) - The Certificate Of Compliance Must Show Traceability To The Marking Applied On Each Individual Item, And Must Contain The Following Information: 1. Contractor's Name, Address And Date. 2. The Contract/purchase Order Number (for Example: N00104-11-p-fa12) 3. The National Stock Number (nsn). The 18 Character National Stock Number For Special Emphasis Material Includes The Two Digit Cog, The Four Digit Fsc, The 9 Digit Niin, And The Two Digit Smic (for Example: 1h 4820 012345678 L1) ("n/a" When Not Applicable). 4. Lubricants, Sealants, Anti-seize, And/or Thread Locking Compounds ("n/a" When Not Applicable). 5. Certification That O-rings, Packing, Gaskets, Or Other Elastomeric Products Were Installed In A Compressed State Within An Assembly Or Sub-assembly, Prior To Expiration Of The Shelf Life ("n/a" When Not Applicable). 6. Manufacturer's Compound Number ("n/a" When Not Applicable). 7. When Weld Procedure Submittal Is Required By The Contract, A Statement That The Approval Date Of The Qualification Data Precedes Any Production Or Repair Welding Performed On This Contract. ("n/a" When Not Applicable). 8. A Statement To The Effect That All Items Furnished On This Contract Are In Full Compliance With The Specifications And Requirements And List Each Contractually Invoked Conformance/compliance Test Performed By Name And That It Was Performed satisfactorily. 9. Contractor's Or Authorized Personnel's Signature. 4. Quality Assurance 4.1 Notes To Dcma Qar And The Contractor - 4.1.1 Dcma Qar And The Contractor For Proprietary Designs - Departures From Contractor Imposed Requirements, Not Specifically Covered By The Contract, Must Be Judged Individually On The Basis Of The Effect, If Any, On Contractual Requirements. When There Is A disagreement Between The Contractor And The Government Representative As To The Effect On Contractual Requirements, The Departure Must Be Considered A Nonconformance And Be Submitted To The Pco For Disposition. 4.1.2 Dcma Qar And The Contractor For Proprietary Designs - All Records Of Departures From Contractor Imposed Requirements Must Be Maintained And Available For Review At The Contractor's Facility. A Copy Must Be Given To The Local Government Representative. A record Of These Departures, Traceable To The Applicablepart Number And Contract Number Must Be Submitted To The Pco. 4.1.3 Dcma Qar And The Contractor For Proprietary Designs - For Proprietary Designs, The Contractor's Part Numbers Are Acceptable For Reference Only. The Delivered Material Must Conform To All Drawings, Specifications, And Other Contractual Requirements. 4.1.4 Dcma Qar - It Is The Responsibility Of Dcma Qar To Review Non-destructive Testing (ndt) Procedures For Navsup Contracts/purchase Orders. 4.1.5 Dcma Qar And The Contractor - The Ecds (electronic Contractor Data Submission) System Is Available For Certain Data Submissions And To Submit Questions And Clarifications, And Waiver Requests On Contracts And Solicitations. Ecds Can Be Found At: https://register.nslc.navy.mil/ 5. Packaging 5.1 Preservation, Packaging, Packing And Marking - Preservation, Packaging, Packing And Marking Must Be In Accordance With The Contract/purchase Order Schedule And As Specified Below. mil-std 2073 Packaging Applies As Found Elsewhere In The Schedule 6. Notes 6.1 Several Definitions Of Terms That Apply To Csi Items Are Listed Below. All Terms May Not Apply To Every Item. 6.1.1 The Ecds (electronic Contractor Data Submission) System Is At: Https://register.nslc.navy.mil/ This Application Will Require Advance Registration Using A Pki Digital Certificate On A Cac. A Vendor User Guide Is Available As Csd001 In The Csd (contract Support Document) Library Within Ecds. 6.1.2 Critical Safety Item (csi) - Any Ship Part, Assembly, Or Support Equipment Containing A Critical Characteristic Whose Failure, Malfunction, Or Absence Of Which Could Cause A Catastrophic Or Critical Failure Resulting In Loss Of, Or Serious Damage To The ship, Or Unacceptable Risk Of Personal Injury Or Loss Of Life. 6.1.3 Critical Process - As Determined By The Twh, Any Process, Operation Or Action Performed On A Ship Csi That Serves To Establish A Critical Characteristic (such As Welding, Soldering, Machining, Polishing, Cleaning, Or Assembling) Or Confirm That A critical Characteristic Is Within Drawing Or Specification Compliance (such As, Testing, Measurement, Or Non-destructive Evaluation). 6.1.4 First Article - Pre-production Models, Initial Product Samples, Test Samples Produced To Ensure A Manufacturer's Capability To Meet Full Specification Requirements. 6.1.5 First Article Test (fat) - Contractually Required Testing And Inspection Of A Supplier's Pre-production, Production, Or "production Representative" Specimens To Evaluate A Manufacturer's Ability To Produce Conforming Product Prior To The Government's commitment To Receive Subsequent Production Items. First Article Testing Is Product Specific And Does Not Assess Manufacturing Process Controls Nor Does It Assure The Effectiveness Of The Manufacturer's Quality Program. 6.1.6 Government Source Inspection (gsi) - Gsi Is Independent Oversight Performed By A Government Representative Usually A Dcma Quality Assurance Representative (qar)) To Assure That Those Unique Product Quality And System Elements, Identified By The contracting Agency As Important, Are Observed And Evaluated. 6.1.7 Quality Assurance Letter Of Instruction (qali) - A Qali Is A Formal Document Initiated By A Contracting Activity That Provides Essential Requirements And Instructions For Contracted Materials To Be Independently Verified And Accepted By A Government representative Prior To Shipment. 6.1.8 Objective Quality Evidence (oqe) - The Quantitative And Qualitative Data Of All Mechanical, Chemical, And Performance Tests Performed (as Required By The Applicable Specification, Drawing, Or Purchase Document) To Prove That The Material Supplied conforms To The Specified Requirements. 6.1.9 Surface Discontinuity - Any Surface Irregularity, Marking, Or Localized Change In Physical Character Of The Surface, Other Than Dimensional, That Exists Infrequently At One Or Several Places. (examples: Burrs, Dents, Nicks, Scratches, Gouges, Pits, center-punches, Scribes, And Tool Marks) Surface Discontinuities Less Than 0.005-inch In Depth Are Acceptable Provided They Do Not Violate Any Other Design Requirements Specified In This Contract/purchase Order. 6.1.10 Traceability Code - A Code Or Number Providing Traceability To The Actual Chemical And Mechanical Properties Of The Specified Heat, Batch, Or Form From Which The Material Originated. 6.1.11 Verification - An Examination Performed To Determine Compliance With A Specific Requirement. 6.1.12 Nonconformance - A Nonconformance Is Defined As Affecting Or Violating The Following: - The Requirements Of This Contract/purchase Order. - Contractually Invoked Drawings (i.e. Envelope Dimensions, Interface Dimensions With Mating Parts/equipment, Center Of Gravity, Weights, Piece Part Identification, Material, Etc.). - Contractually Invoked Federal, Military, Or Commercial Specifications And/or Standards. - Form, Fit, Function, Performance To Contract Requirements, Reliability, Maintainability, Interchangeability, Safety Of Personnel Or Equipment, Or Additional Cost To The Government. 6.1.13 Waiver - A Written Authorization To Accept An Item, Which During Manufacture, Or After Having Been Submitted For Government Inspection Or Acceptance, Is Found To Depart From Specified Requirements, But Nevertheless Is Considered Suitable For Use As Is or After Repair By An Approved Method. 6.1.14 Deviation - A Specific Written Authorization (granted Prior To The Manufacture Of An Item) To Depart From A Particular Requirement(s) Of An Item's Current Approved Configuration Documentation For A Specific Number Of Units Or A Specified Period Of time, And To Accept An Item Which Is Found To Depart From Specified Requirements, But Nevertheless Is Considered Suitable For Use "as Is" Or After Repair By An Approved Method. 6.1.15 Critical Waiver/deviation - This Waiver/deviation Consists Of A Departure Involving Safety. 6.1.16 Major Waiver/deviation - This Waiver/deviation Consists Of A Departure Involving: - Performance - Interchangeability, Reliability, Survivability, Maintainability, Or Durability Of The Item Or Its Repair Parts - Health Or Safety - Effective Use Or Operation - Weight, Stability, Or Structural Integrity - System Design Parameters As Schematics, Flows, Pressures Or Temperatures - Compartment Arrangements Or Assigned Function 6.1.17 Minor Waiver/deviation - This Waiver/deviation Consists Of A Departure Which Does Not Involve Any Of The Factors Listed As Critical Or Major. 6.1.18 Engineering Change (ec) - A Change To The Current Approved Configuration Documentation Of A Configuration Item At Any Point In The Life Cycle Of The Item. 6.1.19 Engineering Change Proposal (ecp) - A Proposed Engineering Change And The Documentation By Which The Change Is Described, Justified, And Submitted To The Government For Approval Or Disapproval. 6.1.20 Class I Ecp - A Class I Ecp Is Approved By The Government's Configuration Control Board And Authorized With A Contract Modification. 6.1.21 Class Ii Ecp - A Class Ii Change Is Typically Reviewed For Concurrence In Classification By The Local Government Representative, Unless Otherwise Specified Elsewhere In The Contract/purchase Order. 6.2 In Accordance With Opnavinst 5510.1 All Documents And Drawings Provided By The U.s. Navy To Perspective Contractors Must Include A "distribution Statement" To Inform The Contractor Of The Limits Of Distribution, And The Safeguarding Of The Information contained On Those Documents And Drawings. 6.2.1 There Are 7 (seven) Separate Distribution Statement Codes Used For Non-classified Documents And Drawings. The Definition For Each Is As Follows: a... Approved For Public Release; Distribution Is Unlimited. b... Distribution Authorized To Us Governments Agencies Only. c... Distribution Authorized To Us Government Agencies And Their Contractors. d... Distribution Authorized To Dod And Dod Contractors Only. e... Distribution Authorized To Dod Components Only. f... Further Distribution Only As Directed By Commander, Naval Sea Systems Command, Code 09t. x... Distribution Is Authorized To Us Government Agencies And Private Individuals Or Enterprises Eligible To Obtain Export Controlled Technical Data In Accordance With Opnavinst 5510.161. 6.3 Ordering Information For Document References - The Department Of Defense Single Stock Point (dodssp), Website Http://www.dsp.dla.mil/, Provides Product Information For The Department Of Defense Index Of Specifications And Standards (dodiss) (i.e.military/federal Specifications And Standards), Data Item Descriptions (dids), And Other Dodssp Products. Most Specifications Can Obtained Directly From Http://quicksearch.dla.mil/ a. Availability Of Cancelled Documents - The Dodssp Offers Cancelled Documentsthat Are Required By Private Industry In Fulfillment Of Contractual Obligationsin Paper Format. Documents Can Be Requested By Phoning The Subscription Services Desk. b. Commercial Specifications, Standards, And Descriptions - These Specifications, Standards And Descriptions Are Not Available From Government Sources. Theymay Be Obtained From The Publishers Of The Applicable Societies. c. Ordnance Standards (os), Weapons Specifications (ws), And Navord Ostd 600 Pages - These Type Publications May Be Obtained By Submitting A Request To: commander, Indian Head Division, Naval Surface Warfare Center code 8410p, 101 Strauss Avenue indian Head, Md 20640-5035 d. On Post-award Actions, Requests For "official Use Only" And "noforn" (not Releasable To Foreign Nationals) Documents Must Identify The Government Contractnumber, And Must Be Submitted Via The Cognizant Defense Contract Management Command (dcmc) For certification Of Need For The Document. On Pre-award Actions Such Requests Must Be Submitted To The Pco For Certification Of Need For The Document. e. Noforn Military Specifications And Standards (including Amendments, Change Notices And Supplements, But Not Interim Changes) To Be Ordered From: contracting Officer navsup-wss code 87321 5450 Carlisle Pike p.o. Box 2020 mechanicsburg, Pa. 17055-0788 f. Nuclear Reactor Publications Assigned Navsea Documents And Identification Numbers (i.e. Navsea Welding Standard, Navsea 250-1500-1) Are To Be Ordered Enue: commanding Officer navsup-wss code 009 5450 Carlisle Pike p.o. Box 2020 mechanicsburg, Pa. 17055-0788 g. Technical Manuals Assigned Navsea Identification Numbers (i.e. Navsea Welding And Brazing Procedure, Navsea S9074-aq-gib-010/248) Are To Be Ordered From: commanding Officer navsup-wss code 1 Support Branch 700 Robbins Avenue philadelphia, Pa. 19111-5094 h. Interim Changes And Classified Specifications Must Be Obtained By Submitting A Request On Dd Form 1425 To Navsup-wss. 6.4 Recent Updates - A Short Description Of Recent Updates To The Technical Requirements Of This Item Are Listed Below, Along With An Implementation Date For Each Issue. The Notes Below Are Only A Generic Quick Reference And Are Provided For Convenience only, Detailed Requirements Will Be Defined Elsewhere In The Technical Sections Of This Contract/purchase Order. ;- 10/20/2016 - Updated Ecds Url - Feb 26 2009 - Clarified Testing And Certs Only Apply To Pieces Listed - Oct 29 2010 - Added Sampling Std For Li In-process Testing - Jun 28 2012 - Updated Ut Of Qq-n-286 Bar 4" And Over - Sep 30 2008 - Thread Inspection Requirements Were Clarified - Dec 20 2022 - Removed Requirement For Vender To Submit Waivers/deviations In Ecds - Jan 05 2012 - Added Wawf To Forward Approved Waivers/deviations With Final Oqe - Dec 17 2011 - Moved Quality Assurance Text Location For Readability - Apr 22 2009 - Added Evidence Of Dcma Observing Test Plate Welding & Ndt - Mar 18 2008 - Identify Applicable Weld Joints With Weld Procedures - Apr 15 2009 - Clarified The Sample Size For Large And Small Lot Sizes - Jan 19 2011 - Added Notification Of Dcma Upon Contract Award - May 02 2009 - Added Lubricants And Sealants To The C Of C - Aug 27 2014 - Took Out Contractor's Phone Number Requirement - Dec 01 2011 - Moved "notes To Dcma Qar" To Qa Section - Jan 5 2017 - Ecds/csd Info Was Added To Definitions In The Notes Section; date Of First Submission=asreq paragraph 10.4 Of Di-qcic-81110 Does Not Apply. date Of First Submission=asreq block 12 - Certification Data Must Be Submitted To Portsmouth Naval Shipyard For Review And Acceptance Prior To Each Shipment Of Material. Certification Documentation Must Be Submitted Via Wawf (wide Area Work Flow). enter In Wawf As Follows: "ship To" N50286 "inspect By" N39040 "accept By" N39040 and Email Notification Field: Port_ptnh_wawf_notification@navy.mil no Material Is To Be Shipped Prior To The Receipt Of Acceptance. date Of First Submission=asreq block 4 - Paragraphs 10.2.1, 10.2.2, 10.2.3, 10.3, And 10.4 Of Di-misc-80678 Do Not Apply. block 12 - Certification Data Must Be Submitted To Portsmouth Naval Shipyard For Review And Acceptance Prior To Each Shipment Of Material. Certification Documentation Must Be Submitted Via Wawf (wide Area Work Flow). enter In Wawf As Follows: "ship To" N50286 "inspect By" N39040 "accept By" N39040 and Email Notification Field: Port_ptnh_wawf_notification@navy.mil no Material Is To Be Shipped Prior To The Receipt Of Acceptance. date Of First Submission=asreq block 4 - Paragraphs 10.2.2, 10.2.3, 10.2.4, And 10.3 Of Di-misc-80678 Do Not Apply. block 12 - Certification Data Must Be Submitted To Portsmouth Naval Shipyard For Review And Acceptance Prior To Each Shipment Of Material. Certification Documentation Must Be Submitted Via Wawf (wide Area Work Flow). enter In Wawf As Follows: "ship To" N50286 "inspect By" N39040 "accept By" N39040 and Email Notification Field: Port_ptnh_wawf_notification@navy.mil no Material Is To Be Shipped Prior To The Receipt Of Acceptance. date Of First Submission=asreq block 12 - Within 120 Days After Contract Award, Submit One Copy Of The Welding Procedure (for Info) With The Qualification Data (for Approval/disapproval). Approval Must Be Obtained Prior To Performing Any Welding. this Review (approval/disapproval) Must Be Within 90 Days From Date Of Receipt. date Of First Submission=asreq block 12 - Within 120 Days After Contract Award, Submit One Copy Of The Welding Procedure (for Info) With The Qualification Data (for Approval/disapproval). Approval Must Be Obtained Prior To Performing Any Welding. this Review (approval/disapproval) Must Be Within 90 Days From Date Of Receipt. date Of First Submission=asreq block 4 - Paragraphs 10.2.1, 10.2.2, 10.2.3, 10.3, And 10.4 Of Di-misc-80678 Do Not Apply. block 12 - Certification Data Must Be Submitted To Portsmouth Naval Shipyard For Review And Acceptance Prior To Each Shipment Of Material. Certification Documentation Must Be Submitted Via Wawf (wide Area Work Flow). enter In Wawf As Follows: "ship To" N50286 "inspect By" N39040 "accept By" N39040 and Email Notification Field: Port_ptnh_wawf_notification@navy.mil no Material Is To Be Shipped Prior To The Receipt Of Acceptance. date Of First Submission=asreq block 12 - See Clause 52.209-3 For Submittal Timeframes.
Closing Date9 Jan 2025
Tender AmountRefer Documents 

VETERANS AFFAIRS, DEPARTMENT OF USA Tender

Others
United States
Details: Page 14 Of 14 no Phone Calls. Send Any Responses By E-mail Only. As This Is A Sources Sought Notice For Market Research Purposes, The Government Will Not Accept Any Technical Questions At This Time. this Is A Sources Sought Notice To Determine Small Business Sources Capable Of Providing Hazardous Waste Management Services Per This Notice Under Naics 562211 (hazardous Spill Containment And Clean-up Equipment And Material). Small Business Size Standard Is $47 Million. Product Service Code (psc) Is 4235 (hazardous Waste Treatment And Disposal). background: this Is A Sources Sought Notice Being Released Pursuant To Federal Acquisition Regulation (far) Part 10: Market Research. This Notice Is Issued Solely For Informational, Market Research, And Planning Purposes Only. It Does Not Constitute A Solicitation Or A Promise To Issue A Solicitation In The Future.â  This Notice Does Not Commit The Federal Government To Contract For Any Service At This Time. further, The U.s.t Department Of Veterans Affairs, Network Contracting Office (nco) 23/ Supply Services Team 1 Is Not At This Time Seeking Offers And Will Not Accept Unsolicited Offers.â  respondents Are Advised That The Federal Government Will Not Pay For Any Information Or Administrative Costs Incurred In Response To This Notice. All Costs Associated With Responding To This Notice Will Be Solely At The Responding Party S Expense. responses To This Notice Are Not Offers And Cannot Be Accepted By The Federal Government To Form A Binding Contract.â  Although The Term Offeror Is Used In This Notice, Your Respective Organization S Response Will Be Treated As Information Only And Shall Not Be Used As An Offer. objective: the Objective Of This Notice Is To Conduct Market Research To Determine If There Are Service Disabled Veteran Owned Small Business (sdvosb) Or Veteran Owned Small Business (vosb) Sources, Or Any Other Small Businesses Capable Of Providing Hazardous Waste Management Services For The St. Cloud, Mn Va Hcs. description Of Service: see Attached Proposed Statement Of Work. places Of Performance: see Attached Proposed Statement Of Work. potential Scope Of Work: see Attached Proposed Statement Of Work. potential Certifications And Licensure: see Attached Proposed Statement Of Work. submittal Of Responses: responses Shall Be Sent Via Electronic Mail Only By 5:00 Pm Central Standard Time (cst), 1-10-2025 To: amanda Patterson-elliott contracting Specialist e-mail: Amanda.patterson-elliott@va.gov offerors Shall Submit A Capability Statement Indicating Their Ability And Experience To Provide The Services Cited Above; Such Statement Shall Also List: name Of Offeror address Of Offeror uei Number Of Offeror point Of Contact Name, Phone Number, And E-mail Of Offeror whether Or Not Vendor Is Sdvosb Or Vosb; Sdvosb And Vosb Will Be Verified Through Vet Biz At Https://veterans.certify.sba.gov/ . whether Or Not Vendor Has General Services Administration (gsa) Federal Supply Schedule (fss) Contract; If So, Please Provide Gsa Fss Contract Number Certifications And Licensure That Its Applicable Staff Holds disclaimer This Rfi Is Issued Solely For Information And Planning Purposes Only And Does Not Constitute A Solicitation. All Information Received In Response To This Rfi That Is Marked As Proprietary Will Be Handled Accordingly. In Accordance With Far 15.201(e), Responses To This Notice Are Not Offers And Cannot Be Accepted By The Government To Form A Binding Contract. Responders Are Solely Responsible For All Expenses Associated With Responding To This Rfi. statement Of Work title: Hazardous Waste Management Services overview: The St. Cloud Va Has A Need For A Qualified Contractor With The Capability And Capacity To Provide Disposal Services For Hazardous Waste, Non-hazardous Chemical Waste, Specialty Waste (i.e. Hazardous Pharmaceutical, High Hazardous Waste, Dea Drug Waste, Non-hazardous Pharmaceutical, And Dual Waste [hazardous Chemical And Bio-hazardous Combined]), Universal Waste, Emergency Spill Response Services, Lab Pack Services That Include Supplies, Labeling, Lab-packing, Consolidation, Shipment, Manifesting, And Consulting. this Contract Will Not Include The Disposal Of Infectious, Bio-hazardous, Radiological, Or Pathological Waste Except For Dual (chemical And Infectious Combined) Waste. acronyms: a. Co Contracting Officer b. Cor Contracting Officer S Representative c. Va Department Of Veterans Affairs d. Vahcs St. Cloud Va Health Care System e. Sow Statement Of Work f. Osha - Occupational Safety And Health Administration g. Epa - Environmental Protection Agency h. Dot Department Of Transportation i. Mpca Minnesota Pollution Control Agency j. Jc Joint Commission k. Mdh Minnesota Department Of Health l. Cdc Centers For Disease Control m. Dea Drug Enforcement Administration n. Rcra Resource Conservation And Recovery Act o. Cfr Code Of Federal Regulations p. Contractor Employee Means All Contractor Staff, Technicians, Personnel, Subcontractors Or Persons Working On Behalf Of The Contractor. 4. Place Of Performance: st. Cloud Va Health Care System, 4801 Veterans Drive, St. Cloud, Mn 56303 period Of Performance: this Contract Will Be A Single Award, Firm Fixed Price Indefinite Delivery, Indefinite Quantity, Service Contract For One (1) Base Year From 02/01/2025 01/31/2026 With Four (4) Option Years. Renewal Of Option Years Is Subject To Availability Of The Next Fiscal Year Funding. qualifications And Special Certifications: contractor Must Obtain All Necessary Permits And/or Licenses Regarding The Pickup And Incineration Or Other Acceptable Disposition As Regulated By State And Federal Epa Guidelines For Hospital Hazardous/dual Waste. *the Primary Contractor Must Own Their Own Licensed Treatment, Storage, And Disposal Facilities. treatment, Storage And Disposal Facilities (tsdfs) Need A Resource Conversation And Recovery Act (rcra) Permit. federal Certificate Of Registration To Transport Hazardous Waste federal Safety Permit To Travel On Highways if Waste Covered Under This Contract Must Be Transported Through A Jurisdiction Which Requires Special Licensing Or Permitting, The Contractor And/or Subcontractor Shall Obtain And Maintain All Necessary Licenses And Permits. The Contractor Shall Provide Copies Of These Licenses And Permits To The Cor. the Contractor And/or Subcontractor Shall, Without Additional Cost To The St. Cloud Vahcs Or Federal Government, Provide And Maintain All Licenses And Permits For Personnel, Trailers, Containers, Vehicles, And Other Resources Required For Proper Transportation And Disposal Of The Wastes Covered Under This Contract In Accordance With All Applicable Federal, State, Local, Municipal, And Va, Laws, Regulations, And Requirements. if Appropriate Licenses And Permits Are Not Maintained In Accordance With These Applicable Laws, Regulations And Requirements, The St. Cloud Vahcs May Terminate The Contract Effective Upon Discovery. the Contractor Is Required To Perform Characterization Of All Waste Streams Identified By Each Facility Using Process Knowledge, Identity Of The Chemicals, And Other Types Of Chemical Analysis Including But Not Limited To Toxicity Characteristic Leaching Procedure (tclp). chemical Wastes Shall Include But Not Be Limited To Flammables, Corrosives, Poisons/toxics/lethal, Reactive Wastes, Dual And Hazardous Waste, And Universal Waste. Work Shall Be Performed In Accordance With All Applicable, Federal, State, Local And All Governing Regulations. the Successful Offeror Must Possess The Necessary Technical Expertise And Resources Required By This Statement Of Work To Be Considered For Contract Award. regulations / Directives / Policies: the Contractor Must Comply With All Applicable Federal (us Epa, Us Osha, Us Dot), State (mn Osha, Mpca), Interstate, National Consensus Standards (jc), And Local Requirements, Rules, Regulations, And Laws Relative To The Handling, Removal, Manifesting, Transportation, Management, Disposal And/or Treatment Of Hazardous, Non-hazardous And Specialty Wastes. the Contractor May Not Attempt To Circumvent Mn01 Lethality Waste Characteristics By Repackaging And Reprofiling In Another State. scope Of Work: contractor Shall Provide All Labor, Personnel, Transportation, Vehicles, Equipment, Tools, And Materials Necessary To Provide Hazardous Waste Management Services. contractor Shall Have The Capability And Capacity To Provide Hazardous, Dual, Universal, And Dea Drug Waste, Waste Disposal Services, Lab Packs, And Removal Of Non-hazardous Chemical Waste Removal And Disposal From The Vahcs, In Accordance With Current Federal, State, And Local Regulations. services Shall Include Pharmaceutical Formulary Review; Technical Consulting; Electronic Record Keeping; Emergency Spill Response; Analysis, Documentation, Waste Treatment, Disposal And Support Services Required To Categorize, Package, Transport, Document And Dispose Of Hazardous, High Hazardous, Dual, And Universal, And Non-hazardous Chemical Wastes And Their Containers. the Certification And Accreditation Requirements Under Va Handbook 6500 Do Not Apply, And As Such A Security Accreditation Package Is Not Required. wate Removal And Shipment: the Contract Will Include Removal, Documentation, And Shipment Of Wastes From The Designated Hazardous Waste Storage Area At The St. Cloud Va Hcs. this Will Include Periodic Shipments Of Dea Controlled Substances Waste And All Labor And Equipment To Package, Transport, Treat And Dispose Of Waste. Protection And Mandates: contractor Will Provide Appropriate Protection For His/her Employees To Be Within Cdc Guidelines That Include Barrier Precautions, I.e., Gloves, Masks, Eyewear And/or Waterproof Gowns, Aprons, (lab) Coats Or Respirators As Necessary. cor Or Cor Designee Will Notify Contractor Of Areas With The Health Care Systems Or Unusual Circumstances Requiring Personal Protective Equipment (ppe) Beyond Standard Practices. contractor Will Comply With All Applicable Osha, Mpca, The Joint Commission, Mdh, Federal, State, Interstate And Local Requirements, Rules, Regulations, And Laws Respecting Control And Abatement Of Pharmaceutical And Hazardous Waste Disposal And Management. obtain All Necessary Permits And/or Licenses Regarding The Pickup And Incineration Or Other Acceptable Disposition As Regulated By State And Federal Epa Guidelines For Hospital Hazardous/dual Waste. this Includes Any Laws In Other States That Are Applicable To The Transportation Of Hazardous/dual Waste Across State Lines. potential Successful Contractor May Be Asked For Documentation That Will Help Determine Contractor Responsibility And Whether The Transporter Is Aware Of And In Compliance With (these) Regulatory Requirements. the Vahcs Requires Hazardous Waste Removal At A Minimum Of Six (6) Visits Per Year/every Other Month. contractor Must Check In With The Cor Or His/her Designee Prior To Beginning Any Work And After Completion. shipments Of Hazardous, Dual, Universal, And Non-hazardous Healthcare Waste Must Be Provided Every Other Month, Or As Needed Based On Generation. periodic Shipments Of Dea Controlled Substances Waste. all Labor And Equipment To Package, Transport, Treat And Dispose Of Waste. technical Expertise To Categorize And Profile Waste And Advise On Federal, State, Municipal And Local Regulatory Compliance. consulting Services at The St. Cloud Va S Request, The Contractor Will Provide Technical Expert Consulting Services On Topics Related To Epa, State Specific Rcra, Dot, And Other Environmental Regulations. pharmaceutical Formulary Review Annual Update annual Pharmaceutical Formulary Review And Report That Identifies All Listed And Characteristic Waste And Codes Including Minnesota Specific Waste Codes. the Contractor Will Provide An Electronic Review Of The Vahcs Formulary And Provide Recommendations As Appropriate. the Completed Review Will Identify All Listed Waste, Characteristic Waste, And Rcra-equivalent Waste, Including State Specific Waste Codes, E.g. Mn01 Lethal. the Final Review Will Be Submitted In Microsoft Excel Spreadsheet In An Electronic File. electronic Record Keeping And Reporting. controlled Substances Disposal contractor Personnel Will Be Escorted By Vahcs Staff. the Contractor Will Be Responsible For The Disposal Of Controlled Substances From The St. Cloud Va Hcs Pharmacy In Compliance With All Applicable Dea, Epa, Mpca, And Local Regulations And The Needs Of The Department Of Veterans Affairs. transportation: Hazardous Waste Shall Be Transported On The Public Highways In Vehicles That Are Licensed, Permitted, Or Otherwise Registered In Accordance With All Applicable Federal, State, Municipal And Local Laws. license Number(s) Must Be Posted On The Exterior Of The Vehicles. each Vehicle Transporting Hazardous Waste Must Have An Emergency Spill Clean-up Plan And Basic Cleanup Equipment On Board. out Of Country Shipments Are Prohibited Under This Contract. disposal: Contractor Will Dispose Of Hazardous Waste In A Manner That Leaves No Future Expense Potential To The Va Or The Federal Government. Chemicals Should Be Disposed Of In The Following Preferred Priority: the Treatment Of The Chemical Waste (at A Facility Approved For Such Processing By An Appropriate State Or Federal Agency) In A Manner That Renders It No Longer A Hazardous Waste As Defined In The 40 Cfr Series. These Processes Include (but Are Not Limited To): reprocessing Or Recovery Followed By Recycling/reuse. chemical Neutralization Or Detoxification. thermal Treatment (e.g. Incineration, Pyrolysis). the Long-term Internment (burial) In A Secure Chemical Landfill Site Approved For Such By The Appropriate State Or Federal Agency. acceptance Of The Hazardous Property (chemical Wastes) At A Properly Permitted Treatment, Storage, Or Disposal Site Does Not Constitute Disposal And/or Completion Of The Contract. it Is The Prime Contractor S Responsibility To Obtain All Necessary Documentation To Prove That The Timely End Disposal Of All Items Has Been Accomplished. contractor Shall Provide The Cor With A List Of Disposal Facilities That Will Be Used In Conjunction With This Contract. This List Must Include The Name Of The Company, Address, City, And State, Zip Code, Telephone Number, Epa Id And State Permit Number. this Contract Will Not Include The Disposal Of Infectious, Bio-hazardous, Radiological, Or Pathological Waste With The Exception Of Dual (chemical And Infectious Combined) Waste. waste Spill Or Release: Should Waste Be Spilled Or Released During The Performance Of Services, Through No Fault Of The St. Cloud Va Hcs, The Contractor Will Be Responsible For Cleanup And All Costs Associated With The Satisfactory Remediation Of The Incident. this Will Include The Cost Of All Labor And Materials, Repair Of Any Damage, And/or Harm Caused To Patients, Visitors, And Staff. Cleanup Shall Be Performed To The Satisfaction Of Regulatory Authorities And The Cor. when Waste Is Spilled Or Release By The Contractor During The Performance Of Services The Contractor Shall Submit A Spill Report. such Incidents Shall Be Reported To The Cor Immediately By Telephone And In Writing No Later Than Seven (7) Workdays After Leaving The Site. the Spill Report Shall List At A Minimum The Type Of Spill, Amount Of Waste, And Personnel Exposed To The Spilled Waste. the Contractor Shall Provide Certification That The Spill Was Cleaned Up, A Statement Concerning The Effect On Any Employees, And A Description Of The Cause And Corrective Measure Instituted By Contractor To Ensure Spills Do Not Occur Again. Schedule: the Contractor And Cor Will Arrange For Scheduled/routine (non-emergency) Services That Occur On A Bi-monthly Basis. work Hours: the Contractor Shall Perform Services During Normal Business Hours, 8:00 Am - 4:30 Pm, Monday Through Friday, Excluding Federal Holidays. The Eleven National Holidays Observed By The Federal Government Are: New Years Day January 1st Martin Luther King Jr. Day Third Monday In January Presidents Day Third Monday In February Memorial Day Last Monday In May Juneteenth June 19th Independence Day July 4th Labor Day First Monday In September Columbus Day Second Monday In October Veterans Day November 11th Thanksgiving Day Fourth Thursday In November Christmas Day December 25th Any Additional Federal Holiday Declared By The President Of The United States if The Holiday Falls On A Saturday, The Previous Friday Will Be Observed And If The Holiday Falls On A Sunday, The Following Monday Will Be Observed. the Cor Or Dot Hazmat Certified Designee Are Available During Those Hours For The Approval/signature Of Shipping Manifests And Other Required Documentation Unless Exigent Circumstances Require Services During An Unscheduled Time. any Service Performed Outside Of Normal Working Hours Shall Be Approved In Advance By The Contracting Officer S Representative Cor. after-hours Access Will Be Coordinated With The Gems Program Manager Or The Gems Program Manager S Site Designee. emergency Services: the Contractor Must Be Available 24/7 And Will Take Responsibility For Up To Two (2) Chemical Spills/releases Per Year At The St. Cloud Va Hcs. the Contractor Shall Provide A Primary And Alternate Point Of Contact To The Cor Within 5 Days Of Contract Award. Information Shall Include A 24-hour Emergency Contact (name, Telephone #, Mobile #) Available During Contractor S Non-business Hours. training For Contractor Personnel: the Contractor S On-site Staff Shall Have Training In Hazardous Waste Handling And Emergency Procedures And Provide Documentation Of This Training. this Training Shall Include Osha, Epa, Minnesota Pollution Control, And Dot (including Hm 181) Regulations. permits, Licenses, And Regulatory Compliance: the Contractor Shall Maintain All Applicable Permits And Licenses For Services Provided And Comply With All Applicable Federal, State, Municipal And Local Laws, Rules, And Regulations. the Contractor Will Obtain And Maintain Any Additional Permits And Licenses That May Be Required Because Of Changes In Regulations. this Includes Compliance With All Occupational Safety And Health Administration (osha), Environmental Protection Agency (epa), Minnesota Pollution Control Agency (mpca), Joint Commission (jc), Minnesota Department Of Health (mdh) Requirements And Requirements In Other States Applicable To The Transportation And Disposal Of Waste That Crosses State Lines. the Following Shall Be Provided To The Contracting Officer With Bid Proposal Submission For Evaluation Purposes And Annually Within Thirty (30) Days Of The Renewal Date Of This Contract With Any Changes To Original Submission Clearly Identified And Highlighted: current Waste Transporter Permit(s) For The Contractor And Subcontractors. list Of All Transfer Stations, Treatment, Storage, And Disposal Facilities (tsdfs) Including Incineration, Wastewater And Sludge Treatment Facilities That Shall Be Utilized During This Contract To Include The Capacity Of These Facilities And The Waste Codes For The Waste Streams They Are Permitted To Accept By Treatment Technology. address, Phone Number And Other Contact Information Shall Be Provided. the Va Reserves The Right To Inspect Each Of These Facilities Before Approving Its Use Or At Any Time During Or After Contract Period While Va Wastes Are Present. copy Of Operator Permit(s) certificates Of Training And Experience Of Contractor/subcontractor Staff And Personnel Who Will Perform Site Work Under This Contract (all Technicians That Will Work On Va Premises Will Be Expected To Have Received At Least The Minimum Training Required By Law As Specified In 29cfr 1910-120, 40 Cfr Parts 260-265 And 49 Cfr Parts 171-178). provide The Contractor S/subcontractor Experience In Hazardous Waste Packaging, Transport, And Disposal. provide A Copy Of Us Epa Identification Number(s) Certificate For Each Business Entity Operated Or Contracted By The Contractor That Will Provide Service Regarding Any Aspect Of Va Waste Disposal Program (i.e. Storage, Transfer, Incinerator Sites.) provided A Copy Of Certificate Of Registration With The State Epa As A Hazardous Waste Hauler For Each Business Entity Operated By The Contractor That Will Provide Hazardous Waste Transportation Services For Any Aspect Of Va Waste Disposal Program. provide Written Acknowledgement Of Responsibility For Acquisition Of All Applicable Business Licenses And Permits Required By Law. contractor Shall Certify That It Acknowledges And Is In Possession Of All Required Business Licenses And Permits. provide A List Of Any Violations And/or Citations That The Contractor And Subcontractors Have Received For Non-compliance With Any Hazardous Waste Laws, Permit Requirements, And/or Osha Requirements For The Past Three Years From The Date Of Submission. contractor Shall Include Information On All Related Business Entities Including Associated Firms That Are Owned By The Contractor Or Owned By A Common Parent Company That Will Be Involved In Any Portion Of The Processing Of Va Waste Disposal Program. if No Discharge Or Violations Have Occurred, Contractor Must Provide A Statement That Certifies No Discharges Or Violations Have Occurred. provide A Plan Describing Standard Operating Procedures (sops) That Will Be Followed While Conducting Normal Hazardous Waste Management Activities. The Contractor Shall Describe: site Safety And Contingency Procedures (e.g. Spill Management). operational Procedures And Site Management Structure. supplies And Equipment Practices. material Sampling Procedures. hazard Assessment And Categorization Procedures. packing Procedures. quality Assurance And Quality Control Procedures To Ensure Materials Are Properly Identified, Categorized, And Packaged, And Paperwork Is Properly Completed. procedures For Gaining Waste Acceptance Into A Transfer/ Disposal Facility. contractor And Project Management Procedures. provide The Following Information Regarding The Hazardous Waste Fleet Owned And Operated By The Contractor: basic Description Of Transportation Services Offered And Capabilities. fleet Description Of Number, Types, And Ages Of Vehicles. description Of Service And Maintenance Programs. types Of Materials Licensed To Haul. latest Dot Or Mcs Rating (include A Copy Of The Last Inspection). the Dot/mn Dot Compliance Record. description Of Driver Qualifications Including Training Programs, And Experience. provide Evidence That Background Checks Have Been Performed On All Employees That Will Perform Any Duties Under This Contract. provide The Following Information On The Contractor's Emergency Response (er) Capabilities (or Any Changes To Original Submission): contractor's Er Policies. Er Capabilities And Experience And Limitations. type Of Er Equipment Maintained (specify If Owned Or Subcontracted And From Whom). personnel Availability, Training, And Experience. contractor's Emergency Response Procedure Shall Describe: how To Request An Emergency Response. how The Contractor Notifies Personnel And Initiates Response Action. incident Command Procedures Followed By The Contractor. er Work Practices. er Protection Of Health And Safety Practices. er Invoicing Policy. provide A Detailed Site Safety Plan That Will Be Used To Ensure That Workers And Nearby Population Will Be Adequately Protected During Packaging And Removal Operations. provide Information Identifying Any Proposed Subcontractors And Identifying Services To Be Performed By The Subcontractors. contractor Must Submit Evidence That Subcontractor Is Qualified And Legally Able To Provide Services. (all Subcontractors Must Be Approved By The Facility Gems Program Manager And Contracting Officer Prior To Performing Any Duties Under This Contract). the Government Reserves The Right To Prohibit The Contractor From Employing The Services Of A Subcontractor Who Does Not Possess The Ability To Satisfactorily Perform In Accordance With The Provisions Of This Statement Of Work. the Use Of A Subcontractor Or Subcontractors Does Not Relieve The Contractor From Any Requirements Set Forth In This Statement Of Work. the Contractor Is Responsible For Ensuring That Any Subcontractor(s) Perform In Accordance With The Terms And Conditions Of This Statement Of Work. Subcontractors Will Also Comply With (j) Of This Section. provide A List Of Names, Titles, Addresses, Telephone Numbers (including Cellular), Pager/beeper Numbers, Facsimile Numbers, And E-mail Addresses Of Key Managers, Supervisors, Customer Service, And Field Service Personnel Performing Under This Contract. provide Written Standard Operating Procedures (sops) For The Collection, Handling, Accumulation, Sampling, Lab Testing, Characterization, Packing, And Shipping Of Hazardous, Universal, And Non-hazardous Wastes. provide A Single Point Of Contact For Each Facility With Backup. provide A List Of Names, Titles, Addresses, Telephone Numbers (including Cellular), Pager/beeper Numbers, Facsimile Numbers, And E-mail Addresses Of Key Managers, Supervisors, Customer Service, And Field Service Personnel Performing Under This Contract. records And Reporting Requirements: contractor Shall Provide A Centralized Online Electronic Waste Tracking System That Is Exportable To The Va System Via Microsoft Excel Spreadsheet. the Centralized Tracking System Will Include A Centralized Database For All Waste Characterizations And Determinations, Waste Profiles, Hazardous Waste Manifests, Universal Bill Of Lading For Universal Wastes, Methods Of Final (end) Disposal, Final (end) Disposal Sites, Shipping Information, Monthly, Quarterly And Annual Waste Generation Reports By Facility, Training Records, A Tracking System For Hazardous Materials Spills And All Recordkeeping, And Reporting Needed To Operate And Manage The St. Cloud Va Hcs Hazardous Waste Management Program. the Contractor Will Be Responsible For Providing A Database That Will Be Able To Generate Reports On Hazardous Waste Activities, Waste Characterization Profiles, Annual Generation By Facility And Other Information Necessary For The Successful Operation And Management Of A Hazardous Waste Management Program. this Will Be Readily Exported To A Format Such As Microsoft Excel. prior To The Shipment Of Waste, The Contractor Will Furnish A Properly Prepared And Legible Copy Of The Appropriate Manifests And Shipping Papers. fully Executed Manifests Will Be Provided To The St. Cloud Va Hcs Within Thirty (30) Days Of Shipment. the Contractor Will Provide A Certificate Of Disposal For All Waste Disposed Clearly Indicating Proper Treatment And Disposal. 14. Safety: The Contractor Shall Take Such Safety Precautions As The Co Or Cor May Determine To Be Reasonably Necessary. the Co Or His/her Designee Will Notify The Contractor Of Any Noncompliance. the Contractor Shall, After Receipt Of Such Notice, Immediately Correct The Conditions To Which Attention Has Been Directed. such Notice, When Served In Person On The Contractor Or His/her Representative At The Site Of Work, Or Telephonically To Contractor S Designated Representative, Shall Be Deemed Sufficient For The Previously Mentioned. if The Contractor Fails Or Refuses To Comply Promptly To Satisfactorily Abate The Hazardous Condition Or Situation, The Co May Issue An Order Stopping All Or Any Part Of The Work And Hold The Contractor In Material Breach Of This Contract. 15. Work Practices And Standards: The Contractor Shall Have Established Standard Operating Procedures That Will Be Followed While Conducting Hazardous Waste Management Activities. this Includes Site Safety And Contingency Procedures, Strike Contingency Plan, Operational Procedures, Use And Maintenance Of Supplies And Equipment Procedures, Material Sampling Procedures, Waste Categorization Procedures, Packaging Procedures, Quality Assurance Plan, Procedures For Gaining Waste Acceptance Into A Facility, And Project Management Procedures. 16. Quality Assurance: The Contractor Shall Maintain A Quality Assurance Program To Assure Services Are Performed In Accordance With Commonly Accepted Commercial Practices. the Contractor Shall Implement Procedures To Identify, Prevent, And Ensure Non-recurrence Of Defective Services. as A Minimum, The Contractor Shall Develop Quality Control Procedures Addressing The Areas Identified In The Next Paragraph. timely Shipment Of Hazardous, Dual, Universal, And Non-hazardous Healthcare Waste And Dea Controlled Substances Waste. timely And Properly Completed Manifest And Shipping Papers. sufficient And Competent Personnel Including Personnel With Expertise To Perform Waste Characterizations, Profiles, And Consultation Services. sufficient Equipment And Supplies In Good Working Condition. fully Functional Online Record Keeping And Reporting System Accessible Always. timely And Accurate Billing System. the Government Will Periodically Evaluate The Contractor Performance By Appointing A Representative(s) To Monitor Performance To Ensure Services Are Received. the Government May Inspect Each Task As Completed Or Increase The Number Of Quality Control Inspections If Deemed Appropriate. likewise, The Government May Decrease The Number Of Quality Control Inspections If Performance Dictates. 17. Competent Personnel: Contractor Personnel Who Perform Services For The St. Cloud Va Hcs Must Be Competent, Experienced, And Qualified To Perform Such Services. all Work Shall Be Performed In Accordance With Established Waste Management Practices. appropriate Handling Of Waste Is Essential For The Safety Of Government And Contractor Employees And Cost Containment. the Contractor Shall Furnish And Ensure All Personal Protective Equipment (ppe) For Contractor Employees Is In Good Condition. the Contractor Shall Provide Employee Training On Established Policies And Procedures For Waste Handling. contractor Employees Providing Site Services Shall Be Certified In Forty (40) Hour Hazardous Waste Operations And Emergency Response (hazwoper) Training And Wear Appropriate Protective Equipment When Handling Hazardous Waste. the Contractor Shall Submit Proof Of Appropriate Training And Experience To The Cor Upon Request. contractor Employees Should Be Enrolled In A Medical Surveillance Program That Meets The Standards Of 29 Cfr 1910 At The Expense Of The Contractor. 18. Identification, Check-in, Parking And Smoking: Contractor Employees Shall Notify Cor Or Designees Upon Arrival To Campus And Prior To Commencement Of Work. during Off-hours Emergency Response Activities Contractor Personnel Should Check In With Va Police If The Cor Or Designee Is Not Available. smoking Is Prohibited On Va Property. possession Of Weapons Or Contraband Is Prohibited. enclosed Containers, Including Tool Kits, Shall Be Subject To Search. 19. Indemnification: It Shall Be Expressly Agreed And Understood By The Contractor And The St. Cloud Va Hcs That The Contractor Agrees To Indemnify The St. Cloud Va Hcs Against All Liabilities, Claims, Penalties, Incident Of Death, Bodily Injuries, Destruction Or Damage To Property, Contamination Or Adverse Effects On The Environment Or Any Violation Of Government Laws, Rules Or Regulations, Caused In Whole Or Part By The Contractor S Breach Of Any Term Of The Contract Or Any Negligent Or Willful Act Or Omission Of The Contractor, Its Employees Or Subcontractors In The Performance Of This Contract. 20. Penalties And Fines: The Contractor Shall Satisfy All Applicable Regulatory Agency Requirements. in The Event A Regulatory Agency Assesses A Monetary Fine Against The St. Cloud Va Hcs For Violations Caused By The Contractor, The Contractor Shall Reimburse The St. Cloud Va For The Fine. 21. Authorized Services: Only The Services Specified In The Sow Will Be Authorized Under The Contract. the Co In Consultation With The Cor May Authorize Additional Services Or Repairs Under A Separate Purchase Authorization. reimbursement Will Not Be Made Unless Prior Authorization Is Obtained. 22. Invoices And Payment: Payment Of Services Rendered Under This Contract Will Be Made In Arrears Upon Satisfactory Completion Of Each Service And Receipt Of A Properly Prepared Invoice. invoice Must Include, But Not Limited To: contract Number purchase Order Number manifest Number(s) complete And Accurate Description Of Services dates Of Performance amounts unit Price extended Totals any Other Data Relevant For Payment Purposes the Government Shall Not Authorize Payment Until Such Time That The Cor Or His/her Designee Receives All Properly Executed And Signed Documentation. 23. Insurance: Owners And Contractor S Insurance: The Contractor Shall Obtain At His Own Expense, General Liability Insurance In The Amount Of Not Less Than $500,000.00 For Protection Against Claims Of Personal Injury, And $50,000.00 Per Occurrence For Damage To Property, Arising Out Of This Contract. professional Liability Insurance: The Contractor Shall Obtain At His Own Expense, Professional Liability Insurance For Services To Be Performed Pursuant To This Contract, Insuring The Contractor Against Malpractice Or Errors And Omissions Of The Contractor In The Amount Required By State And Local Authorities. $10 Million In Pollution Control Liability Insurance. workers Compensation And Employer Liability: $100,000.00 automobile Liability: $200,00.00 Per Person And $500,000.00 Per Occurrence For Bodily Injury And $20,000 Per Occurrence For Property Damage. at All Times During Performance, The Contractor Shall Maintain With The Contracting Officer, A Current Certificate Of Insurance Showing At A Minimum, The Insurance Required Above, And Providing Thirty (30) Days Written Notice To The Contracting Officer By The Insurance Company Prior To Cancellation Or Material Change In Policy Coverage. note: Any Additional Charges Claimed Must Be Approved By The Contracting Officer In Writing Before Service Is Completed!
Closing Date10 Jan 2025
Tender AmountRefer Documents 
7721-7730 of 7728 archived Tenders