GOVERNOR CELESTINO GALLARES MULTI SPECIALTY MEDICAL CENTER Tender
GOVERNOR CELESTINO GALLARES MULTI SPECIALTY MEDICAL CENTER Tender
Costs
Summary
Supply, Delivery, Installation, Testing And Commissioning Of 4 Lots Various Medical Equipment (batch 2) For Gov. Celestino Gallares Multi-specialty Medical Center , Medical And Dental Equipment ,governor Celestino Gallares Multi-specialty Medical Center
Description
Description Gov. Celestino Gallares Multi-specialty Medical Center Invitation To Bid For Supply, Delivery, Installation, Testing And Commissioning Of 4 Lots Various Medical Equipment (batch 2) For Gov. Celestino Gallares Multi-specialty Medical Center 1. The Gov. Celestino Gallares Multi-specialty Medical Center (gcgmsmc), Through The Health Facilities Enhancement Program 2024 Intends To Apply The Sum Of Ninety-two Million Pesos Only (php92,000,000.00) Being The Abc To Payments Under The Contract For Cb-2024-11-0004. Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. The Gcgmsmc, Through The Health Facilities Enhancement Program 2024 Intends To Apply The Sum Of Ninety-two Million Pesos Only (php92,000,000.00) Being The Abc To Payments Under The Contract For Each Lot/item.et Al. Lot No. Item/description Quantity Unit Cost Total Cost 1 Treadmill With Electrocardiogram, Exercise / Stress Testing System + Cardiovascular Information System 1 35,000,000.00 35,000,000.00 2 Portable X-ray Machine 1 17,000,000.00 17,000,000.00 3 Ultrasound Machine 1 20,000,000.00 20,000,000.00 4 Flexible Endoscopy 1 20,000,000.00 20,000,000.00 Grand Total 92,000,000.00 Bids Received In Excess Of The Abc For Each Lot Shall Be Automatically Rejected At Bid Opening. 2. The Gcgmsmc, Now Invites Bids For The Above Procurement Project. Delivery And Installation Of The Goods Is Required Within 120 Calendar Days Upon Receipt Of Notice To Proceed. Bidders Should Have Completed, Within 3 Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii (instructions To Bidders). 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. A. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra No. 5183. 4. Prospective Bidders May Obtain Further Information From Gcgmsmc Through Electronic Mail Via Procurement@cpspecialtycenter.org Or Through The Cellular Number 09209437250. 5. A Complete Set Of Bidding Documents May Be Acquired And Downloaded By Interested Bidders From Gcgmsmc Google Drive From (procurement@cpspecialtycenter.org) On November 15- December 10, 2024 And Upon Payment Of The Applicable Fee For The Bidding Documents, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Indicated Below In Accordance With The Following Schedule: Lot No. Item/description Total Cost Bidding Documents Fee (in Philippine Peso) 1 Treadmill With Electrocardiogram, Exercise / Stress Testing System + Cardiovascular Information System 35,000,000.00 25,000.00 2 Portable X-ray Machine 17,000,000.00 25,000.00 3 Ultrasound Machine 20,000,000.00 25,000.00 4 Flexible Endoscopy 20,000,000.00 25,000.00 The Procuring Entity Shall Allow The Bidder To Present Its Proof Of Payment For The Fees Through Online Banking Or Online Deposit With The Following Bank Details: Bank Name: Development Bank Of The Philippines Account Name: Gcg Multi-specialty Medical Complex Account Number: 00-0-15490-780-5 "for Bidders Choosing To Pay Via Online Transfer Or Bank Deposit, Please Ensure That Proof Of Your Successful Transaction Is Promptly Sent To The Procurement Email Address: Procurement@cpspecialtycenter.org. In Compliance With Coa Circular Number 2021-014, Clause 5.2, An Acknowledgement Receipt Will Be Issued As Proof Of Verified And Received Payment. Access To Bidding Documents Will Be Granted Only Upon Presentation Of This Acknowledgement Receipt. 6. The Gcgmsmc Will Hold A Pre-bid Conference On The 27th Day Of November 2024 At 0900h At Room 3c-e310 Located At The 3rd Floor Of Gcgmsmc Building C, Malayo Sur Cortes, Which Shall Be Open To Prospective Bidders. 7. Bids Must Be Duly Received By The Bac Secretariat Through Manual Submission On Or Before The 10th Day Of December 2024 At 0900h At Gcgmsmc Procurement Office Room 3c-w327 Located At The 3rd Floor Of Gcgmsmc Building C, Malayo Sur, Cortes, Bohol. Late Bids Shall Not Be Accepted. 8. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 14. 9. Bid Opening Shall Be On The 10th Day Of December 2024 At 0900h At Room 3c-e310 Located At The 3rd Floor Of Gcgmsmc Building C, Malayo Sur Cortes. Bids Will Be Opened In The Presence Of The Bidders’ Authorized Representatives Together With Their Company Id. 10. The Gcgmsmc Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections 35.6 And 41 Of The 2016 Revised Irr Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 11. Submission Of Hardcopies: The Winning Bidders Shall Submit Their Original Eligibility And Technical Documents Described In Itb Clause 10 In One Sealed Envelope Marked "original - Technical Component", And The Original Of Their Financial Component In Another Sealed Envelope Marked "original Financial Component", Sealing Them All In An Outer Envelope Marked "original Bid". Each Copy Of The First And Second Envelopes Shall Have 2 Copies And Similarly Sealed Duly Marking The Inner Envelopes As "copy No. 1 Technical Component" And "copy No. 1- Financial Component” And "copy No. 2- Technical Component" And "copy No. 2- Financial Component" And The Outer Envelope As "copy No. 1" And "copy No. 2" Respectively. These Envelopes Containing The Original And The Copies Shall Then Be Enclosed In One Single Envelope. Please Take Note That All Notarized Documents Must Be Treated As Original Copies For All The Submitted Documents (original, Copy 1, And Copy 2). It Is Imperative That Each Copy Retains Its Original Notarization To Ensure Legal Validity And Compliance. The Original And The Number Of Copies Of The Bid As Indicated In The Itb Clause 15 Shall Be Typed Or Written In Ink And Shall Be Signed By The Bidder Or Its Duly Authorized Representative/s. All Envelopes Shall: A. Contain The Name Of The Contract To Be Bid In Capital Letters; B. Bear The Name And Address Of The Bidder In Capital Letters; C. Be Addressed To The Procuring Entity's Bac In Accordance With Itb Clause 1; D. Bear The Specific Identification Of This Bidding Process Indicated In The Itb Clause 1. 12. For Further Information, Please Refer To: Mary Grace L. Simbajon Jessa O. Quiñal Procurement Office Procurement Office Malayo Sur, Cortes, Bohol Malayo Sur, Cortes, Bohol Procurement@cpspecialtycenter.org Procurement@cpspecialtycenter.org +639209437250 +639452478632 November 14, 2024 Approved By, (signed) Doreen A. Lugo, Lpt Bac Chairperson Noted By, (signed) Laurence Elliot R. Tirol, Md, Fpcp Medical Center Chief I Head Of Procuring Entity --------------------------------------------------------------------------------------------------------- 1 1 Lot Supply, Delivery, Installation, Testing & Commissioning Of Treadmill With Electrocardiogram, Exercise / Stress Testing System + Cardiovascular Information System Treadmill With Electrocardiogram, Exercise / Stress Testing System Power Supply : Ac Operation; Input Voltage: 200 To 240 Volts Ac; Power Consumption: 350 Watts Max Display : At Least 22 Inch Diagonal Display Size; Resolution: At Least 1680 X 1050 Pixels; Tiltable Height Adjustable Flat Screen For Optimal Positioning Dedicated Workflow Keys Risk Stratification: Critical Algorithms, Including Heart Rate Recovery (hrr) And T-wave Alternans (twa) Functional Response: Metabolic Equivalents (mets) Level Indicated During Procedure Ischemia Detection: St/hr Hysteresis Analysis Which Improves Cad Detection Wireless Acquisition: Use Of Wireless Technology To Obtain Signals Or Data Capable Of Creating A Remote Workstation On Any Pc For Viewing Editing And Printing Stress Data Capable Of Adding Automated Blood Pressure And Oxygen Saturation Data Into The System System Is Capable Of Integrating With Stress Echocardiography, Nuclear Imaging, And Ambulatory Blood Pressure Analysis Open System Architecture Uses Industry Standard Communication Protocols Such As Dicom And Xml; Data Export Via Xml, Pdf And Xls To Match Emr Or His Files Automative Timeout And Log-in For Increased Security Advanced Security Protections Include Data Encryption, Username And Password Authentication, Secure Network Connections, Electronic Delivery Of Security Patches And Updates, Constant Threat Monitoring And Disaster Recovery Plan Weight: Patient Weight Capacity (kg): Up To 227; Treadmill Net Weight (kg): Up To 193 Power Requirements: 220/240 Vac, 1-phase, 50-60 Hertz, 20-amp Power Supply; Must Have Dedicated 15a Service Speed Range: 0.1 To 15.0 Miles Per Hour, 0.2 To 24.0 Kilometers Per Hour; Self-calibrating; Adjustable In 0.1 Mph Or 0.1 Kph Increments Incline Range: 0 To 25%, At Least 0.5% Incremental Movements; Self-calibrating Running Surface: At Least 56 By 160 Centimeters (cm); Running Belt Tracking System; Cushioned Running Deck Absorbs Shock Of Foot Falls; Self-lubricated And Reversible Running Deck; Step-up Low Profile Deck Height: At Least 18 Cm From Floor. Communication Ports: Rs232 Female Serial Port; Usb 1.0 “b” Port. Floor Surface Footprint: At Least 84 By 200 Cm Level Surface. Dual Comparative Speed Sensors Auto Runaway Shutdown Auto Communication Loss Shutdown Manual Twist Lock Emergency Stop Button Manual Stop Tether Braking System For Safe Patient Off-loading Fire Rated Motor Pan Hood Enclosure Cardiovascular Information System The System Shall Allow Cardiac Technologists To Enter Comments Which Will Not Be Reflected In The Report Or Distributed To Electronic Medical Record (emr). The Gui Should Allow Searching In Forms – Quick Search Of Specific Field Name, Label Or Value In Forms With Immediate Link Which Takes The User To The Field And Highlights It For Documentation. The Gui Should Allow Searching For Values Within Reports. The System Should Support Structured Reporting, With Quick Reports, Side By Side Reporting, And Real-time Synchronization Of The Report To Data Fields In The Form. Report Templates Must Be User-definable. The Reporting System Shall Be Able To Auto Populate Findings Where Relevant And The Cardiologist Must Be Able To Override Any Auto Populated Data. The System Should Support Comprehensive Reporting Functions For Structural Heart End-to-end Electrophysiology (ep) Workflow In Conjunction With Ep Recording System In The Market Pediatric Echo Reporting Incorporated With Boston Z-scores The System Should Support Ingestion And Non-editable Display Of Pdf Reports From 3rd Party Systems, Such As Hemodynamic Systems, Including Trackings/full Disclosure From Holter Monitoring Systems Or Ecg Management Systems The System Shall Be Able To Receive Studies Sent Directly From Modalities And Devices (without Drawing From Digital Imaging And Communications In Medicine (dicom) Modality Worklist). The System Shall Be Able To Automatically Create Patients From Received Studies, If The Patient Is Not Yet Available In The System Database. The System Shall Prevent Separate Cardiologists From Simultaneously Reporting On The Same Examination, And Alert The Users. The System Shall Have A Charge Verification And Communication Functionality To Hospital Billing It Systems. The System Should Support Result Distribution In A Variety Of Formats, Including Hl7, Pdf, And Sending Discrete Xml Values To External Systems Embedded Advanced Post-processing Tools For Cath And Us (2d, 3d And 4d) Via Dedicated Ultrasound Reporting System/picture Archive Communication System Embedded 3d Advanced Visualization With Advanced Processing Web-enabled Deployment Cardio Imaging Solution Integration 1280 X 1024 Resolution Particulars Workstation: (1) Unit Windows 10 64bit Or Newer Version X86 Microprocessor, Ram - At Least 32gb Ssd - At Least 512gb, Network - At Least 1gb With Peripheral Component Interconnect Express Slot For Medical Graphic Controller Worklist Monitor: (1) Unit Of At Least 27" Monitor Warranty : 5 Years And On The Graphic Controller, 20,000 Hours Backlight Warranty Guaranteed At 400cd/m2 Calibrated Luminance. Minimum Of Five (5) Year/s For Spare Parts & Service Upon Acceptance By End-user Conduct Free Preventive Maintenance At Least Semi-annually Or According To Manufacturer's Recommendation/s Within Warranty Period. Corrective Maintenance Within A Maximum Of Fourteen (14) Days Upon Notification From End-user; Technical Support Staff Response Time Within At Least Two (2) Hours Via Remote Access Or Maximum Of Twenty-four (24) Hours Either Via Physical Presence On Site. Equipment Down-time Within Warranty Period Due To Inherent Defect/s And/or Fault/s Shall Be Added To The Total Warranty Period Availability Of Support Staff Within Visayas Delivery, Installation, Commissioning, Permit/s, Training And Other Related Expenses Incurred Will Be Shouldered By Winning Bidder, Where Applicable Vendor Must Provide Intensive Operational Or Application Training With Certification/s For End-user/s And Intensive Technical Training For Maintenance/biomedical Staff. Vendor Must Have Existing/active Quality Management System Certification E.g. Ce0123 (medical Device), Or Its Equivalent For Importation, Warehousing, Installation & Servicing Of Active And Non-active Medical Services. Vendor And / Or Manufacturer Must Provide Fda Certificaton: Fda 510(k) K131246 Or Its Equivalent, If Applicable Vendor Shall Agree To Provide Factory Or Principal Manufacturer Training And/or Certification For At Least One (1) In-house Biomedical Technologist Or It Personnel And/or Other End User. Progress Billing And Payment May Be Availed By The Winning Bidder As Follows, Otherwise, Full Payment Is Due At The Completion Of The Project And Requirements: 15% Upon Delivery At Site; 30% Upon Complete Installation, And 55% Upon Completion Of Project And/or Acceptance Of End-user. Vendor Shall Warrant That The Product Supplied Shall Meet The Published Specifications. Vendor Shall Provide No Less Than Five (5) Years Warranty On Each Of The Equipment For Spare Parts And Service Upon Acceptance By End User/s. Vendor Agrees To Provide Free Of Charge All Parts And Labour Necessary To Repair Each Of The Equipment Purchased During The Period Covered By The Warranty And Replacement Of Any Item/s And/or Part/s Found To Be Defective In Material Or Workmanship Under Normal Use. Equipment Shall Be Delivered Complete With All Cabling, Connectors, And All Other Accessories Necessary For Full Operation Of The Equipment, Where Applicable. Vendor Must Certify That All Products Quoted Must Be In Current Production And Publicly Available As Of The Date Of This Tender. Unproven Future Products Shall Not Be Accepted. All Desired Features Listed Must Be In Current Production, Installed And In Use At The Time Of Quote/bid. Equipment Must Meet All Currently Applicable Safety Standards, Local And International Where Applicable. Vendor May Include Post-warranty Comprehensive Preventive Maintenance Program Proposal For The Next 3-4 Years And Must Also Indicate Cost Estimated For Major Spare Part/s. Any And All Components Not Manufactured By The Vendor/primary Manufacturer Shall Be Listed As Such With Name/address/contact Information Of The Manufacturer Supplied. Vendor Shall Provide Automatic Voltage Regulator (avr) And Uninterrupted Power Supply (ups) To Back Up The System. Equipment Shall Be Delivered With At Least Two (2) Copy Of All Service Manuals And At Least Two (2) Copy Of All User Manuals. Certification From The Manufacturer That The Units Are Brand New And Not With Any Issues Or Defect. Vendor Shall Confirm And Certify In Writing That Parts And Labor Will Be Available For The Quoted Equipment For Not Less Than Five (5) Years After The Warranty Period. Principal's/manufacturer's Product Portfolio Must Have Been Present In The Local Market For The Past Ten (10) Years. Equipment Must Be Manufactured By A Known And Reputable Company With Certificate Of Iso 9001:2015 And/or Iso 13485:2016 Or Its Equivalent. Completion Period For Delivery Must Not Exceed 120 Calendar Days And Succeeding Installation Must Not Exceed 120 Calendar Days. Any Deviation From This Limit Requires Prior Approval By The Head Of The Procuring Entity (hope) And Only Applies During Extenuating Circumstances. Completion Period For Delivery Must Not Exceed 120 Calendar Days And Succeeding Installation Must Not Exceed 120 Calendar Days. Any Deviation From This Limit Requires Prior Approval By The Head Of The Procuring Entity (hope) And Only Applies During Extenuating Circumstances. Principal’s / Manufacturer’s Products Must Have Been Present In The Local Market For The Past Ten (10) Years Vendor Shall Provide Integration, Interoperability And Migration Solutions Exclusively Using Filmless Platforms Such As Medical Grade Clinical Monitors, 2d/3d Workstations, Dicom Enabled Printers And Cd/dvd Medical Disc Publishers, Medical Film Digitizers , Dicom Archives, Foresight Analog To Digital Conversion System, Mri Compatible Infusion Pump And Patient Monitor, And Digital Or Suites ----------------------------------------------------------------------------------------------- 2 1 Lot Portable X-ray Machine General Information General Purpose Digital Mobile Xray For Patient In Recumbent And Seated 32 Kw At 100 Kv 100 Ms Large Focus And 16 Kw At 100 Kv 100 Ms Small Focus Non Motorized Examination Can Be Performed By Connecting To The Mainpower Switch 2-axis Counterbalanced Column Arm With 90° Tube Head Rotation And ± 317° Arm Rotation Allows Easy Adjustment For All The Different Projections Generator Power Output: Large Focus: At Least 32 Kw At 100 Kv 100 Ms Small Focus: At Least 16 Kw At 100 Kv 100 Ms Kvp Range: 40 Kv To 150 Kv Mas Range: 0.32 Mas To 200 Mas Kvp Accuracy: < ± 3 Kv (40 Kv To 60 Kv); < ± 5 Kv (60 Kv To 150 Kv) Mas Accuracy: At Least ± 0.1 Mas (0.32 Mas To 2 Mas); ± 6 % (> 2 Mas) Shortest Exposure Time: At Least 1 Ms Max. Exposure Time: At Least 3.2 S Exposure Release: Handswitch With 5 M Coiled Cord Or Infrared Remote Control 1 Protection Against Electric Shock: Class I Acc. To Iec 60601-1 Xray Tube Tube Housing (single Tank With Rotating-anode Tube) Stabilization: Microprocessor-based Adjustment And Regulation During Exposure Focal Spot Nominal Value: Dual (0.6 Mm / 1.2 Mm) Anode Angle: At Least 16° Anode Speed: At Least 180 Hz (high Speed) Heat Storage Capacity Of Tube Housing: At Least 830 Kj (1170 Khu) Heat Storage Capacity Of Anode: At Least 210 Kj (300 Khu) Collimator: Manually Adjustable Multileaf Collimator, Rotatable ± 90° Collimator Light And Light Field Intensity: Led Min. 180 Lux At 1 M Sid Advanced Collimator: Pediatric Filters For Lower Dose Imaging And V-laser For Even More Magnesium-alloy Shell-type Frame Dose Area Product Measurement Chamber Typical Filtration: At Least < 0.4 Mm Al Equivalent Dap Resolution: At Least 0.01 Μgym2 Maximum Measurable Dap: 1 X 105 Μgym2 Flat Panel Wireless Detector Wireless Detector: At Least 35 Cm X 43 Cm (14 In X 17 In) Detector Detector Technology: Csi Scintillator, Amorphous Silicon (a-si) Detector Acquisition Matrix: At Least 2304 X 2800 Pixels (full Iq Performance Area) Pixel Size: At Least 150 Μm Acquisition Depth (gray Scales): At Least 16 Bit Active Area: Up To 34.6 Cm X 42.0 Cm (13.6 In X 16.5 In) Thickness: At Least 15 Mm (0.6 In) Detector Weight: ≤ 3.7 Kg (8.2 Ibs) With Battery Max. Load: At Least 300 Kg (661 Ibs) (patient Lying Down) And At Least 100 Kg (220 Ibs) (patient Standing) Data Transfer: W-lan, 802.11 A/b/g/n/ac Battery Operation Capacity: At Least 8 Hours Operation Time With At Least 320 Images, 1 Image Every 90 Sec And At Least 840 Images In Operation Mode, 1 Image Every 30 Sec. Built-in Rechargeable Battery Battery Operating Time Of At Least 8 Hours Of Continuous Use Charging Location: External Battery Charger Charging Time From Empty State To Full Charge: Within 3 Hours Image Acquisition Image Display: Fit To Window View Of Full Image Image Processing Functions: Rotation, Vertical And Horizontal Flipping, Zoom,windowing For Contrast/brightness, Black/white Image Inversion Graphic Functions: Quantification With Angle Distance Measurement Text Functions: Marking, Annotations, Image Comments, R/l Markers Tube Line Enhancement: Amplified Display Of Tubes And Lines In The Image For Position Control Security: Malware Protection Data Transfer Dicom Network Interfaces: Transmission Of Images To A Dicom Network For Viewing And Archiving Confirmation From The Image Archive Storage Commitment Printing Of Images To A Dicom Laser Camera Via Virtual Film Sheet Retrieval Of Images To A Picture Archival System Get Worklist Function For Importing Patient Data From A Data Management System (ris/his) Cr And Dx Worklist Entries Modality Peroformance Procedure Step Function For Sending Examination Statistics And Dose Information To A Data Management System Sending Of Dose Values For Each Study To An Archiving System Documentation Image Data Management: Export To Usb Device In Jpg, Dicom Dcm Or Dicom Raw Transmission Of Images To Network Automatic And Selective Printing With Virtual Film Sheet Provide- Statistics Of Rejected Images Significant Features Wlan Connectivity For Increase Reach And Improved Connectivity Pediatric Filters Transparent Filters For Lowering The Patient Entry Dose Remote Service That Allows Hardware And Software Diagnosis, Customer Care Service And System Configuration Accessories Radiation Protection Equipment, Such As Lead Gowns, Gonadal Shields, And Thyroid Shields. Vendor Shall Warrant That The Product Supplied Shall Meet The Published Specifications. Warranty Period For Five (5) Years After The Acceptance. Minimum Of Five (5) Year/s For Spare Parts & Service Upon Acceptance By End-user. Vendor Must Repair Or Replace Any Item And/or Part/s Of The Equipment Found To Be Defective In Material Or In Workmanship Under Normal Use, Provided That The Equipment Is In Good Working Condition Thereafter, Within The Warranty Period. Conduct Free Preventive Maintenance At Least Semi-annually Or According To Manufacturer's Recommendation/s Within Warranty Period. Corrective Maintenance Within A Maximum Of Fourteen (14) Days Upon Notification From End-user; Technical Support Staff Response Time Within At Least Two (2) Hours Via Remote Access Or Maximum Of Twenty-four (24) Hours Either Via Physical Presence On Site. Equipment Down-time Within Warranty Period Due To Inherent Defect/s And/or Fault/s Shall Be Added To The Total Warranty Period. Availability Of Support Staff Within Visayas. Delivery, Installation, Commissioning, Permit/s, Training And Other Related Expenses Incurred Will Be Shouldered By Winning Bidder, Where Applicable. Vendor Must Provide Intensive Operational Or Application Training With Certification/s For End-user/s And Intensive Technical Training For Maintenance/ Biomedical Staff. Must Certify The Availability Of Spare Parts For The Next Five (5) Years. Vendor Must Have Existing/active Quality Management System Certification (e.g. Ce0123 Medical Device), Or Its Equivalent For Importation, Warehousing, Installation & Servicing Of Active And Non-active Medical Services. Vendor And / Or Manufacturer Must Provide Fda Certificaton: Fda 510(k) K170476 Or Its Equivalent. Shall Be Delivered With At Least Two (2) Copies Of User Manuals. Vendor Must Certify That All Products Quoted Must Be In Current Production And Publicly Available As Of The Date Of This Tender. Unproven Future Products Shall Not Be Accepted. All Desired Features Listed Must Be In Current Production For At Least 2 Years, Installed And In Use At The Time Of Quote/bid Vendor Shall Agree To Provide Factory Or Principal Manufacturer Training And/or Certification For At Least One (1) In-house Biomedical Technologist Or It Personnel And/or Other End User. Progress Billing And Payment May Be Availed By The Winning Bidder As Follows, Otherwise, Full Payment Is Due At The Completion Of The Project And Requirements: 15% Upon Delivery At Site; 30% Upon Complete Installation, And 55% Upon Completion Of Project And/or Acceptance Of End-user. Completion Period For Delivery Must Not Exceed 120 Calendar Days And Succeeding Installation Must Not Exceed 120 Calendar Days. Any Deviation From This Limit Requires Prior Approval By The Head Of The Procuring Entity (hope) And Only Applies During Extenuating Circumstances. Principal’s / Manufacturer’s Products Must Have Been Present In The Local Market For The Past Ten (10) Years Any And All Components Not Manufactured By The Vendor/primary Manufacturer Shall Be Listed As Such With Name/address/contact Information Of The Manufacturer Supplied Vendor Shall Confirm And Certify In Writing That Parts And Labor Will Be Available For The Quoted System For Not Less Than One (1) Year After The Warranty Period Vendor Shall Provide Integration, Interoperability And Migration Solutions Exclusively Using Filmless Platforms Such As Medical Grade Clinical Monitors, 2d/3d Workstations, Dicom Enabled Printers And Cd/dvd Medical Disc Publishers, Medical Film Digitizers , Dicom Archives, Foresight Analog To Digital Conversion System, Iramed, Mri Compatible Infusion Pump And Patient Monitor, And Digital Or Suites Vendor To Shoulder Any Expenses Related To Delivery, Installation, Commissioning, Permit/s,training And Other Sundries Necessary For The Complete Installation Of The Equipment ------------------------------------------------------------------------------------------------------------ 3 1 Lot Ultrasound Machine Electrical Power Voltage: 100 - 240 Vac Frequency: 50/60 Hz Power Consumption: Maximum Of 0.9 Kva With Peripherals Console Design At Least 4 Active Physical Probe Ports, At Least 1 Inactive Probe Storage Port Wireless Probe Connection, Capable Of Connecting Wireless And Linear Probe. Integrated Ssd (at Least 1 Tb) Integrated Dvd-r Multi Drive On-board Storage Of Thermal Printer With Inclusion Of At Least 10 Rolls Of Thermal Paper Integrated Locking Mechanism That Provides Rolling Lock And Caster Swivel Lock Front And Rear Handles Easily Removable Air Filters Operating System: Windows 10 Enterprise Ltsc 2019 (64-bit) Keyboard Operating Keyboard Adjustable In Height And Rotation Ergonomic Hard Key Layout Interactive Back-lighting Integrated Recording Keys For Remote Control Of Up To 4 Peripheral Devices Or Dicom Devices Integrated Gel Warmer Touch Screen At Least 12-inch High-resolution, Color, Touch, Display Screen Interactive Dynamic Software Menu Brightness Adjustment Key/feature Monitor At Least A 23.8-inch Wide, High-resolution High Definition Unit Display. Can Be Moved At Least 350 Mm (13.7 Inches) Horizontally In Both Directions. Can Be Moved At Least 150 Mm (5.9 Inches) Vertically At Least A 90° Swivel In Both Directions. Fold-down And Lock Mechanism For Transportation Resolution: At Least 1920 X 1080 Pixels. Anti-glare Viewing Angle: 89°/89°/89°/89°. Transducer Type Sector / Phased Array Curved Linear Array Microcurved Linear Array Linear Array Matrix Array (linear) Volume Probes (4d) Split Crystal Transesophageal Echocardiogram (tee) Probe Operating Modes Capability Brightness Mode / 2d Grayscale Motion Mode Color Flow Mode Power Doppler With Directional Map Non Doppler Color Flow For Hemodynamic Study Digital Tgc With 8 Independent Controls System Features Pre-programmable Categories Simplified User Interface For High Volume Workflow Maximum System Bandwidth: 25 Mhz Cine Memory: At Least 1 Gb Connectivity: (a) Can Do Lan Or Wireless (b) Dicom 3.0 (c) Public Sr Template (d) Structured Reporting Compatible With Vascular, Obstetric (ob), Cardiac And Breast Standards (e) Remote Monitoring Scanning Parameters Digital Beamforming;infinite Number Of Effective Channels Frame Rate: At Least 9,000 Hz Displayed Imaging Depth: 0 – 100 Cm Doppler Mode: (a) Prf: 0.4 Khz - 35.5 Khz (b) Velocity Range: ± 10 - 2,870 Cm/s Minimum Depth Of Field: 0 - 2 Cm (zoom) (probe Dependent) Maximum Depth Of Field: 0 – 100 Cm (probe Dependent) Continuous Dynamic Receive Focus Software Features Automatic Optimization Optimize B-mode Image To Help Improve Contrast Resolution With One Button Press Selectable Amount Of Contrast Resolution Improvement (low,medium, High) Continuously Adjusts B-mode Axial And Lateral Gain Uniformity And Overall Gain Level Suppressing The Noise Adjusts Region Of Interest Position, Sample Volume Position, And Steering With One Button Press Capable Of Non Doppler Color Flow For Hemodynamic Study Easy, Fast Visualization Of Tiny Vessels, Displaying As A 3d Effect. Available In Color, Power Doppler And Microvascular Imaging (mvi) Assistant Protocol Workflow Enhancement Tool For Standardized And Repetitive Exams Include Factory Programs User-defined Programs And Import Functionality Steps Include Image Annotations, Mode Transitions, Basic Imaging Controls And Measurement Image Comparison Side-by-side Comparison Of Previous Ultrasound And Other Modality Exams During Live Scanning Strain Elastography Qualitative And Semi-quantitative To Assess The Stiffness Of A Tissues. Should Be Able To Have A Qualitative Graph To Show Consistency Of Compression Available On Convex, Linear And Endovaginal Probe Shear Wave Elastography Quantitative Software For Assessing The Stiffness Of A Tissue. Measured In Kpa Or M/s Or Kpa And M/s With Quality Mode Can Do Multiple Acquisition Of Frames In One Breath Hold Able To Do A Re-measure In The Archives Available On Convex, Linear (low And High Frequency) And Endovaginal Probe Live Steatosis Quantification Able To Quantify Fatty Liver Hepatic Protocol Able To Measure Liver Steatosis And Liver Stiffness At The Same Frame. Able To Capture Multiple Frames In One Breath Hold. Virtual Convex Provides A Convex Field Of View Should Be Compatible To Spatial Compounding Available On All Linear And Sector Transducers Speckle Reduction Imaging High Definition Speckle Reduction Imaging Compatible With Side-by-side Dual-view Display Compatible With All Linear, Convex And Sector Transducers Compatible With B-mode, Color, Contrast Agent And 3d/4d Imaging Pre And Post Processing Panoramic Imaging Allows A Real-time Representation Of Long Anatomical Areas (e.g.patellar Tendon), Can Scan Up To 60 Cm Length Home Page Collection Of User’s Favorite Parameters From Measurement/comments/body Patterns Programmable Buttons Measurement For B/m/doppler User Defined Annotation For Selected Exam Category Continuous Optimization Delivers Continuously Optimized Images With Incredible Uniformity From Near To Far Field Artificial Intilligence (ai) Based Features System Capable That The User To Identify A Lesion In Breast, Thyroid Or Liver Lesion And On One Click, The Ultrasound Will Automatically Trace The Lesion System Capable To Automatically Measure The Fetal Biometry. Can Be Turned On And Off. An Ai Based Software That Automatically Determines The Location Of Vessels Both For Color Doppler And Pulsed Wave (pw) Mode. System Familiarization With The Color Preset For Abdominal Ultrasound. Automatic Measurement Of Kidney For Both Left And Right. Breast Measurement Package A Dedicated Breast-specific Measurement Package That Allows User To Make Labeling, Measuring And Describing Lesion Easy Leverage The Bi-rads Lexicon Criteria/assessment Organizes Multiple Measurements Into A Convenient Worksheet Thyroid Measurement Package Thyroid-specific Measurement Package Enables Labeling, Measuring And Describing Nodules, Lymph Nodes And Parathyroids Multiple Measurements Can Be Organized Into A Convenient Worksheet And Sends Results Via Dicom Sr Auto Intima Media Thickness (imt) Automated Method Of Measuring The Intima Media Thickness Of The Common Carotid Artery (cca) Or Internal Carotid Artery (ica) From Multiple Samples Across A User Defined Length. Photo Assistant Photograph Relevant Anatomy And Include Photos With The Clinical Images Provides Value Context For Documentation And Comparison After A Procedure Utilizes Tablet Or Phone Remote App With The Use Of Android Phone Or Tablet, The Ultrasound System Can Be Utilized Using Major Keys Like Major Modes, Freeze/print, Cursor And Etc Fusion Imaging The System Must Support A Technique That Fuses Two Different Imaging Modalities. For Hepatic Interventions, Real-time Ultrasound (us) Should Be Capable Of Being Fused With Other Imaging Modalities, Including Ct, Mri, And Pet/ct. Convex, Microconvex And Linear Probe To Have An Integrated Gps Tracker When Using The Fusion Feature. Improved Speckle Reduction Imaging Acquire Extraordinary Images Across A Broad Range Of Patients, With Incredible Uniformity From Near- To Far-field And The Penetration Power To Manage High-bmi Patients Efficiently. Micro Vascular Imaging Detects Slow Flow And Small Vessels With New Clutter Filtering, And Can Use Together With The 3d Like Feature Blood Flow. Start Protocol Automatically Select Category, Probe, Preset, Or Scan Assistant From Worklist Exam Description Learn The Category, Probe, Preset, And Scan Assistant Based On Exam Description 3d/4d Ultrasound Three-dimensional Image And Provide An Even Clear Image Of The Baby. Enhanced 3d Image A Skin Like Appearance Of A 3d/4d Image To Better Asses The Structure Of A Fetus. 3d/4d Image Rendering Automate Render Line Placement In 3d/4d Imaging, Enabling Clinicians To Easily Acquire Surface-rendered Images. Probes Convex Probe Application: Abdomen, Ob/gyn, Pediatric, Peripheral Vascular, General Musculoskeletal Bandwidth: 1.0 – 6.0 Mhz Number Of Elements: At Least 192 Field Of View (max.): 80° Cardiac/ Sector Probe Application: Adult Cardiac, Pediatric Cardiac, Adult Cephalic, Abdominal Imaging Bandwidth: 1.0 - 5.0 Mhz Number Of Elements: At Least 288 Field Of View (max.) : 120° Wireless Probe, Convex And Linear Convex Applications: Abdomen, Ob, Peripheral Vascular, General Musculoskeletal, Superficial Musculoskeletal, Cardiac And Pleural Bandwidth: 2 - 5 Mhz Number Of Elements: At Least 128 Field Of View (max.): 67° Linear Applications: Peripheral Vascular, Thyroid, Scrotal, Breast, General Musculoskeletal, Superficial Musculoskeletal, Pediatric Cephalic And Pleural Bandwidth: 3 - 12 Mhz Number Of Elements: At Least 192 Field Of View (max.): 38 Mm Linear Probe 1. Applications: Abdomen, Peripheral Vascular, Neonatal, Pediatric, Neonatal Transcranial, General Musculoskeletal, Superficial Musculoskeletal And Small Parts Inculding Breast, Thyroid And Scrotal 2. Bandwidth: 4.0 – 16.0 Mhz 3. Number Of Elements: At Least 1008 4. Field Of View (max.): 50 Mm Endocavitary Probe 1. Applications: Ob/gyn, Urology 2. Bandwidth 3.0 – 10.0 Mhz 3. Number Of Elements: At Least 192 4. Field Of View (max.): 180° Convex Volume Probe 1. Application: Abdomen, Ob/gyn, Pediatric, Neonatal 2. Bandwidth: 2.0 - 8.0 Mhz 3. Number Of Elements: At Least 192 4. Field Of View (max.): 80° Endocavitary Volume Probe 1. Application: Ob/gyn, Urology 2. Bandwidth: 3.0 - 10.0 Mhz 3. Number Of Elements: At Least 192 4. Field Of View (max.): 180° Vendor Shall Warrant That The Product Supplied Shall Meet The Published Specifications. Vendor Shall Provide (5) Years Warranty For Equipment Covering 1 Probe From 2nd Year To 5th Year Upon Acceptance By End User/s. Vendor Agrees To Provide Free Of Charge All Parts And Labour Necessary To Repair Each Of The Equipment Purchased During The Period Covered By The Warranty And Replacement Of Any Item/s And/or Part/s Found To Be Defective In Material Or Workmanship Under Normal Use. Equipment Shall Be Delivered Complete With All Cabling, Connectors, And All Other Accessories Necessary For Full Operation Of The Equipment, Where Applicable. Vendor Must Certify That All Products Quoted Must Be In Current Production And Publicly Available As Of The Date Of This Tender. Unproven Future Products Shall Not Be Accepted. All Desired Features Listed Must Be In Current Production, Installed And In Use At The Time Of Quote/bid. Conducts Bi-annnual Preventive Maintenance And Calibration With Corresponding Certificates And Stickers Attached To The Unit. Vendor Must Respond With Technical Support Staff, Either Remotely Within Two (2) Hours Or In-person Where Applicable, Within At Least Twenty-four (24) Hours Upon Notification Of End-user; Must Perform Corrective Maintenance Within A Maximum Of Fourteen (14) Days Upon Notification Of End-user; Equipment Must Meet All Currently Applicable Safety Standards, Local And International Where Applicable. Vendor May Include Post-warranty Comprehensive Preventive Maintenance Program Proposal For The Next 3-4 Years And Must Also Indicate Cost Estimated For Major Spare Part/s. Any And All Components Not Manufactured By The Vendor/primary Manufacturer Shall Be Listed As Such With Name/address/contact Information Of The Manufacturer Supplied. Vendor Shall Provide Automatic Voltage Regulator (avr) And Uninterrupted Power Supply (ups) To Back Up The System. Equipment Shall Be Delivered With At Least Two (2) Copy Of All Service Manuals And At Least Two (2) Copy Of All User Manuals. Certification From The Manufacturer That The Units Are Brand New And Not With Any Issues Or Defect. Vendor Shall Confirm And Certify In Writing That Parts And Labor Will Be Available For The Quoted Equipment For Not Less Than Five (5) Years After The Warranty Period. Vendor Shall Provide Comprehensive Training Of Users In Operation, Basic And Advance Maintenance Shall Be Provided With Certificates, Vendor Shall Agree To Provide Factory Or Principal Manufacturer Training And/or Certification For At Least Two (2) In-house Biomedical Technician Or Engineer And End User. Principal's/manufacturer's Product Portfolio Must Have Been Present In The Local Market For The Past Ten (10) Years. Equipment Must Be Manufactured By A Known And Reputable Company With Certificate Of Iso 9001:2015 And Iso 13485:2016 Or Its Equivalent. Progress Billing And Payment May Be Availed By The Winning Bidder As Follows, Otherwise, Full Payment Is Due At The Completion Of The Project And Requirements: 15% Upon Delivery At Site; 30% Upon Complete Installation, And 55% Upon Completion Of Project And/or Acceptance Of End-user. Completion Period For Delivery Must Not Exceed 120 Calendar Days And Succeeding Installation Must Not Exceed 120 Calendar Days. Any Deviation From This Limit Requires Prior Approval By The Head Of The Procuring Entity (hope) And Only Applies During Extenuating Circumstances. -------------------------------------------------------------------------------------------------------- 4 1 Lot Flexible Endoscopy Video Processor High Definition Video Outputs: Digital Visual Interface, Serial Digital Interface, Video Graphics Array Standard Video Outputs: S-video, Composite Video Baseband Signal Hd Video Recording: Built-in Workstation, Data Management & Report Editing After Procedure Can Access Data Management, Report Editing, Image Capture And Hd Video Recording Hard Disk: At Least 500gb Internal Capacity Power Requirement: 220-240 V, 60 Hz Chromoendoscopy Modes: Spectral Focused Imaging, Versatile Intelligent Staining Digital Zoom: 1.4x, 1.6x, 1.8x Color Adjustment: Red, Blue, Chroma, ±15 Levels Patient Data: At Least 10000 Records Lightsource Main Lamp: At Least 4 Light Emitting Diode Lamps With Average Working Hours Of At Least 10,000 Hours With Lifetime Indicator Light Control: Manual And Auto Adjust Air Pump: Off, Low, Mid, High Hot Plugging With Spectral Focused Imaging, Versatile Intelligent Staining With White Light Mode Power Requirement: 220-240 V, 60 Hz Monitor Medical Grade Light Emitting Diode Monitor With At Least 26 Inches Size Resolution: At Least Full Hd 1080p Visual Angle: Horizontal 178° / Vertical 178° Video Signal Input : Digital Visual Interface X1, Video Graphics Array X1, Video X1, Serial Digital Interface X1 Video Signal Output : Digital Visual Interface & Serial Digital Interface Power Requirement: 220-240 V, 60 Hz Trolley With Master Switch And Centralized Power Control With At Least Four (4) Layer Racks With Scope Holders With Built In Automatic Voltage Regulator Gastroscope Depth Of View (mm): 3-100 Field Of View: At Least 140° Distal End Diameter (mm): At Least 9.3 Bending Section Diameter (mm): At Least 9.3 Instrument Channel Diameter (mm): At Least 2.8 Angulations: At Least Up:210°; Down:90°; Left:100°; Right:100° Working Length (mm): At Least 1050 Total Length (mm): At Least 1350 Inclusion Of Distal End Cap Colonoscope Depth Of View (mm): 3-100 Field Of View: At Least 140° Distal End Diameter (mm): At Least 12 Bending Section Diameter (mm): At Least 12.5 Instrument Channel Diameter (mm): At Least 3.8 Angulations: At Least Up:180°; Down:180°; Left:160°; Right:160° Working Length (mm): At Least 1350 Total Length (mm): At Least 1700 Inclusion Of Distal End Cap Particulars Vendor Shall Warrant That The Product Supplied Shall Meet The Published Specifications. Vendor Shall Provide No Less Than Five (5) Years Warranty On Each Of The Equipment For Spare Parts And Service Upon Acceptance By End User/s. Vendor Agrees To Provide Free Of Charge All Parts And Labour Necessary To Repair Each Of The Equipment Purchased During The Period Covered By The Warranty And Replacement Of Any Item/s And/or Part/s Found To Be Defective In Material Or Workmanship Under Normal Use. Equipment Shall Be Delivered Complete With All Cabling, Connectors, And All Other Accessories Necessary For Full Operation Of The Equipment, Where Applicable. Vendor Must Certify That All Products Quoted Must Be In Current Production And Publicly Available As Of The Date Of This Tender. Unproven Future Products Shall Not Be Accepted. All Desired Features Listed Must Be In Current Production, Installed And In Use At The Time Of Quote/bid. Conducts Bi-annual Preventive Maintenance And Calibration With Corresponding Certificates And Stickers Attached To The Unit. Vendor Must Respond With Technical Support Staff, Either Remotely (2 Hours) Or In-person Where Applicable, Within At Least Twenty-four (24) Hours Upon Notification Of End-user; Must Perform Corrective Maintenance Within A Maximum Of Fourteen (14) Days Upon Notification Of End-user. Equipment Must Meet All Currently Applicable Safety Standards, Local And International Where Applicable. Vendor May Include Post-warranty Comprehensive Preventive Maintenance Program Proposal For The Next 3-4 Years And Must Also Indicate Cost Estimated For Major Spare Part/s. Any And All Components Not Manufactured By The Vendor/primary Manufacturer Shall Be Listed As Such With Name/address/contact Information Of The Manufacturer Supplied. Vendor Shall Provide Automatic Voltage Regulator (avr) And Uninterrupted Power Supply (ups) To Back Up The System . Equipment Shall Be Delivered With At Least Two (2) Copy Of All Service Manuals And At Least Two (2) Copy Of All User Manuals. Certification From The Manufacturer That The Units Are Brand New And Not With Any Issues Or Defect. Vendor Shall Confirm And Certify In Writing That Parts And Labor Will Be Available For The Quoted Equipment For Not Less Than Five (5) Years After The Warranty Period. Vendor Shall Provide Comprehensive Training Of Users In Operation, Basic And Advance Maintenance Shall Be Provided With Certificates, Vendor Shall Agree To Provide Factory Or Principal Manufacturer Training And/or Certification For At Least Two (2) In-house Biomedical Technician Or Engineer And/or End User. Principal's/manufacturer's Product Portfolio Must Have Been Present In The Local Market For The Past Ten (10) Years. Equipment Must Be Manufactured By A Known And Reputable Company With Certificate Of Iso 9001:2015 And/or Iso 13485:2016 Or Its Equivalent. Progress Billing And Payment May Be Availed By The Winning Bidder As Follows, Otherwise, Full Payment Is Due At The Completion Of The Project And Requirements: 15% Upon Delivery At Site; 30% Upon Complete Installation, And 55% Upon Completion Of Project And/or Acceptance Of End-user. Completion Period For Delivery Must Not Exceed 120 Calendar Days And Succeeding Installation Must Not Exceed 120 Calendar Days. Any Deviation From This Limit Requires Prior Approval By The Head Of The Procuring Entity (hope) And Only Applies During Extenuating Circumstances.
Contact
Tender Id
3659ecf7-42a2-3711-9cba-e082b0aea75dTender No
11483895Tender Authority
GOVERNOR CELESTINO GALLARES MULTI SPECIALTY MEDICAL CENTER ViewPurchaser Address
-Website
http://notices.philgeps.gov.ph