Electrical Tenders
Electrical Tenders
The City Government Of Baguio Tender
Others...+1Electrical and Electronics
Philippines
Closing Soon10 Jan 2025
Tender AmountPHP 15.5 Million (USD 267 K)
Details: Description Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 1 1 Lot Various Materials For Smart City Command Center 15,500,000.00 22 Unit 16 Port Poe Switch - 16 Port Poe Switch - Cpu Core Count 1 Cpu Nominal Frequency 800 Mhz Size Of Ram 256 Mb Storage Size 16 Mb Storage Type Flash Mtbf Approximately 200'000 Hours At 25c Cooling Type Passive Poe-out Ports Ether1-ether16 Poe Out 802.3af/at Max Out Per Port Output (input 18-30 V) 1.1 A Max Out Per Port Output (input 30-57 V) 0.6 A Max Total Out (a) 2.8a (18v-30v) & 1.4a (48v-57v) X2 10/100/1000 Ethernet Ports 16 Number Of 1g Ethernet Ports With Poe-out 16 Sfp+ Ports 2 Certification Ce, Eac, Rohs Ip Ip54 Warranty :1 Year 88 Unit Adjustable Stainless Steel Strapping Band - Adjustable Stainless Steel Strapping Band - Material: Stainless Steel 304 Width: 1/2 Inch Thickness: 0.5 Mm Length: 30 Meters 44 Unit Cable Loop Holder - Cable Loop Holder - Galvanized Steel Pole Mountable 4 Branches At Least 400mmx400mm 1 Box Cat6 Utp Pure Copper Outdoor Cable - Cat6 Utp Pure Copper Outdoor Cable - Cat6 Utp Pure Copper Outdoor Cable 40 Unit Cctv Channel License - Cctv Channel License - Single Anpr Camera Connection For Use With Central Software Warranty :perpetual Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 1 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 40 Unit Cctv Lpr Camera - Cctv Lpr Camera - Camera Image Sensor 1/1.8″ Progressive Scan Cmos Max. Resolution 2688 × 1520 Min. Illumination Color: 0.001 Lux @ (f1.2, Agc On) Shutter Time 1/25 S To 1/100,000 S Day & Night Ir Cut Filter Lens Focal Length & Fov 2.8-12 Mm: Horizontal: 113.5° To 39°, Vertical: 58.4° To 22.7°, Diagonal: 141.3° To 44.3° Aperture 2.8-12 Mm: F1.38, 8-32 Mm: F1.7, 10-50 Mm: F1.7 Illuminator Built-in Supplement Light Type Ir Light Built-in Supplement Light Range Up To 40 M Ir Wavelength 850 Nm Video Main Stream 50 Hz: 25 Fps (2688 × 1520, 1920 × 1080, 1280 × 760, 704 × 576, 352 × 288) 60 Hz: 30 Fps (2688 × 1520, 1920 × 1080, 1280 × 760, 704 × 576, 352 × 288) Sub-stream 50 Hz: 25 Fps (1920 × 1080, 1280 × 760, 704 × 576, 352 × 288) 60 Hz: 30 Fps (1920 × 1080, 1280 × 760, 704 × 576, 352 × 288) Video Compression H.264 And H.265 Encoding Main Stream: H.265/h.264/mjpeg Sub-stream: H.265/h.264/mjpeg Video Bit Rate 32 Kbps To 16 Mbps Protocols Tcp/ip,icmp,http,https,ftp,sftp,dhcp,dns,ddns,rtp,rtsp,rtcp,ntp,smtp,snmp,igmp,qos,ipv4/ipv6,udp,ssl/tls,isup,arp,802.1x Simultaneous Live View Up To 6 Channels Road Traffic And Vehicle Detection Coverage Up To 3 Lane(s) Smart Function Traffic Flow Detection:average Speed, Traffic Flow, Queuing Length, And Traffic Status Incident Detection: Congestion, Stopped Vehicle, Lane Change, Wrong-way Driving, Speeding, Low-speed Driving Capture Speed Range 5 To 120 Km/h Blocklist And Allowlist Max. 50000 Records Warranty :2 Years Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 2 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 5 Unit Cctv Nvr - Cctv Nvr - Supports Redundant Power Supply To Improve The System Stability Supports Hdd Hot Swap With Raid0, Raid1, Raid5, Raid 6, And Raid10 Storage Scheme Configurable. Either Normal Or Hot Spare Working Mode Is Configurable To Constitute An N+1 Hot Spare System. Supports Some Specialist Cameras, Including People Counting Camera/anpr (automatic Number Plate Recognition) Camera/fisheye Camera Supports Video Analytic Functions Such As Vehicle Detection, License Plate Recognition --video & Audio Input -ip Video Input 128-ch -incoming/outgoing Bandwidth 576 Mbps/512 Mbps -incoming/outgoing Bandwidth (raid Mode) 576 Mbps/512 Mbps -tls Outgoing Bandwidth 128 Mbps, Or 64 Mbps (when Raid Is Enabled) --video & Audio Output -protocol Hikvision, Acti, Arecont, Axis, Bosch, Brickcom, Canon, Hunt, Onvif (version 2.5), Panasonic, Pelco, Rtsp, Samsung, Sony, Vivotek, Zavio --video & Audio Output -hdmi Output Two Independent Hdmi Outputs Of 4k Resolution. Resolution: 4k (4096 × 2160), 4k (3840 × 2160)/30hz, 2k (2560 × 1440)/60hz, 1080p (1920 × 1080)/60hz, Uxga (1600 × 1200)/60hz, Sxga (1280 × 1024)/60hz, 720p (1280 × 720)/60hz, Xga (1024 × 768)/60hz -vga Output 1-ch. Resolution: 1080p (1920 × 1080)/60hz, Uxga (1600 × 1200)/60hz, Sxga (1280 × 1024)/60hz, 720p (1280 × 720)/60hz, Xga (1024 × 768)/60hz --video & Audio Decoding -decoding Format H.265, H.265+, H.264, H.264+, Mpeg4, Mjpeg (for Hikvision Ip Camera Only) -video Resolution 32 Mp/24 Mp/12 Mp/8 Mp/7 Mp/6 Mp/5 Mp/4 Mp/3 Mp/1080p/uxga/720p/vga/4cif/dcif/2cif/cif/qcif *: 32 Mp And 24 Mp Is Only Available For Channel 1 To 4 When Ultra Hd Resolution Mode Is Enabled -synchronous Playback Up To 16 Channels -capability 1-ch@32 Mp (8160 × 3616, 30 Fps)/5-ch@8 Mp(30 Fps)/10-ch@4 Mp(30fps)/20-ch@1080p(30 Fps)/40-ch@720p(30 Fps) *: The Length Or Width Of Camera Resolution (each Track) Cannot Exceed 4096 Pixels --hdd -interface 16 Sata Interfaces Supporting Hot-plug -capacity Up To 10 Tb For Each Hdd -storage Extension 1 × Esata Interface, 2 × Mini Sas Interface (optional) --raid Raid Type Raid0, Raid1, Raid5, Raid 6, And Raid10 --network Management -protocol Ipv6, Https, Upnp, Snmp, Ntp, Sadp, Smtp, Nfs, Iscsi, Pppoe, Ddns Network Interface 4, Rj45 10m/100m/1000m Self-adaptive Ethernet Interface --external Interface -usb Interface Front Panel: 2 × Usb 2.0; Rear Panel: 2 × Usb 3.0 Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 3 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) -alarm Input/output 16/8 --general -power Supply 100 To 240 Vac, 50 To 60hz, 5 A -fan Redundant Dual Ball Bearing Fan; Speed Adjustable -consumption (without Hdd) ≤ 140w -warranty :2 Years 1. Responsibility Of The Supplier 1.1 Supply And Delivery Of Ict Equipment 1.2 Inventory Of The Items Deliverd With The Following Details 1.2.1 Brand 1.2.2 Model 1.2.3 Serial Number 1.2.4 Quantity 1.3 The Bidder Must Ensure That All Components Delivered Will Be Brand New 1.4 All Equipment Provided Must Be Compatible And Working With The Cctv System As A Whole 1.5 Materials And Equipment Delivery Within 90 Days 1.6 Cctv Contractor Should Have Manufacture Authorization And Certification. 1.7 Contractor Must Have A Valid Iso 9001:2015 Certificate 1.8 All Equipment Provided Must Be Capable/compatible To Interconnect With The Existing Systems Located At The Smart City Command Center (sc3) To Be Viewable And Configurable In The Sc3. 80 Unit Cctv Nvr Surveillance Hard Drive - Designed And Built To Handle Heavy Surveillance Workloads Advanced Vibration Management Capacity 10tb Interface Sata 6 Gb/s Max. Sustained Transfer Rate Od (mb/s) 250mb/s Cache (mb) 256 Tarnish Resistant Yes Mtbf 1,500,000 Hr Warranty :2 Years 15 Set Command Center Desktop Computer - Minimum Specifications: Operating System: Microsoft Windows 11 Pro 64bit Processor: Intel Core I5 14600k Turbo Frequency 5.3ghz 14 Cores/20 Threads, 24mb Cache, Socket Lga1700 Cpu Air Cooler: Twin Tower Cpu Air Cooler, With 6x6mm Sintered Copper Heatpipes, With 2x140mm Fans Motherboard: B760 Chipset, Lga1700 Socket, Ddr5 4xdimm Matx Form Factor Ram: Ddr5 5600mhz, 32gb (dual 2x16gb) Memory Modules Gpu: Rtx 4070, 12gb Gddr6/gddr6x Ssd: 512gb Capacity R/w 560/520 Mb/s 3d Tlc Ssd 2.5 Inch Form Factor Hdd: Capacity 2tb, 7200 Rpm, 256mb Cache, 3.5 Inch Form Factor Power Supply: 1000 Watts, 80 Plus Gold Certified, Fully Modular, With 120mm Smart Hydraulic Bearing (hyb) Fan, With Active Pfc, Mtbf: >100,000 Hours Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 4 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) Case: Tempered Glass Mid Tower Atx Case With At Least 3 Fans Monitor: 2 Units, 24 Inches, Resolution: Fhd 1920 X1080, Aspect Ratio:16:9, Brightness: 250cd, Color Gamut Ntsc 72%, Refresh Rate: 100hz, Response Time: 5ms(gtg), Connectivity: 1x Hdmi 1x Displayport Keyboard: Usb Connectivity, With Backlight, Rubber Dome, Usb Connectivity, Multi-key Anti-ghosting, Polling Rate: 1000hz, Cable Type: Attached, Braided, Cable Length: 5.9ft Mouse: Usb Connectivity, Optical Sensor, Mouse Button Durability: 30m L/r Click, Cable: 1.8m Tangle Free Rubber, Dpi: 12,400 Dpi Ups: Max Configurable Power (watts) 650 Watts / 1.2kva, At Least 3 Universal Socket Warranty :2 Years 2 Unit Command Center Field Laptop - Command Center Field Laptop - Intel Core I7-13700hx Processor (30 Mb Smart Cache, 2.1 Ghz Performance-core With Turbo Boost Max Technology 3.0 Up To 5.0 Ghz, Overclock Capable) 1x 16gb Of Ddr5 4800mhz System Memory, Upgradable To 32 Gb Using Two Sodimm Modules 2x 512gb Nvme Ssd; Total Of 1tb 16 Display With Ips (in-plane Switching) Technology, Wqxga 2560 X 1600, High-brightness (500 Nits) Nvidia® Geforce Rtx 4060 With 8 Gb Of Dedicated Vram Warranty :2 Years 2 Unit Command Center Printer - Command Center Printer - A3 Wi-fi Duplex All-in-one Ink Tank Printer Print Speed Of Up To 25.0 Ipm Prints Up To A3+ (for Simplex) Automatic Duplex Printing Ultra-high Page Yield Of 7,500 Pages (black) And 6,000 Pages (colour) Wi-fi, Wi-fi Direct, Ethernet Printer Type: Print, Scan, Copy, Fax With Adf Minimum Ink Droplet Volume: 3.8 Pl Print Direction: Bi-directional Printing Nozzle Configuration:800 X 1 Nozzles Black, 256 X 1 Nozzles Per Colour (cyan, Magenta, Yellow) Maximum Resolution: 4800 X 2400 Dpi Automatic 2-sided Printing: Yes (up To A3) Print Speed: Photo Default - 10 X 15 Cm / 4 X 6 " *1: Approx. 43 Sec Per Photo (border) / 52 Sec Per Photo (borderless)*2 Draft, A4 (black / Colour): Up To 32.0 Ppm / 22.0 Ppm *2 Iso 24734, A4 Simplex (black / Colour): Up To 25.0 Ipm / 12.0 Ipm *2 Iso 24734, A4 Duplex (black / Colour): Up To 16.0 Ipm / 9.0 Ipm *2 Iso 24734, A3 Simplex (black / Colour): Up To 13.5 Ipm / 6.0 Ipm *2 Iso 24734, A3 Duplex (black / Colour): Up To 10.0 Ipm / 5.0 Ipm *2 Warranty :1 Year Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 5 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 1 Unit Command Center Video Wall Controller - Command Center Video Wall Controller - Interface Alarm In Alarm Out 8-ch Alarm Out 8-ch Alarm In Serial Interface Rs-232 (rj45) × 1, Rs-485 × 1 Usb Interface Usb 2.0 × 2 Network Interface Rj45 × 2, 10 M/100 M/1000 Mbps Self-adaptive Ethernet Interface Optic Interface × 2 100 Base-fx/1000 Base-x Supports Optoelectronic Self-adaptation Video Walls 1 Video Wall Size <= 8 Layers Per Screen 1080p × 3 Or 4k × 1.5 Layers Layers Per Screen × Output Interface(s) Split Window Yes Scene Auto-switch Delay 3s Auto-switching Plans Support 256 Auto-switching Plans Max. Input Resolution 4k Audio Encoding Format G722.1, G711u, G711a, Aac-lc Video Output Interface Type Hdmi 1.4 Video Output Interface(s) 8 Video Decoding Resolution Up To 32 Mp Warranty:2 Years 8 Unit Command Center Video Wall Display - Command Center Video Wall Display - Display Panel Diagonal Size Class 55 Measured 54.6 Resolution 3,840 X 2,160 (16:9) Brightness (typ.) 700 Nit Orientation Landscape/portrait Haze 25% Contrast Ratio (typ.) 4,000:1 Type Va Active Display Area 1,209.6 (h) X 680.4 (v) Pixel Pitch (mm) 0.315 X 0.315 Color Gamut Ntsc 72% Operation Hour 24/7 Connectivity / Sound Input Video Dp 1.2 (1), Hdmi 2.0 (3) Audio N/a Usb Usb 2.0 X 2 Tuner N/a Output Audio Stereo Mini Jack Wifi / Bt O/o External Control Rs232c (in/out), Rj45 Speaker 10w 2ch Mechanical Spec Dimension (mm / In.) With Heavy Duty Full Motion Tv Wall Mount Warranty :3 Year 44 Unit Din Rail Mount - Din Rail Mount - 35mm At Least 7.5mm Depth Aluminum 22 Unit Electrical Box Enclosure - Electrical Box Enclosure - Electricalbox Panel Box Metal Enclosure(ip66, Nema 4 & 12) 300x250x150 Mm W/ 2 Fans And Fan Filter With Pole Mount Bracket X1 Molded Case Circuit Breaker Mccb30a 220v 2 Pole Din Rail Mount Type X1 Residual Current Circuit Breaker 63a 220v With Grounding/earthing 2 Pole Din Rail Mount Type X1 Grounding Bus Bar With Insulator X1 Din Rail Mount Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 6 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 40 Roll Fiber Optic Connectivity - Fiber Optic Connectivity - Fiber Optic Connectivity 2.0 Kms 4 Core Fiber Optic Cable Maintenance Of Outside And Inside Plant Equipment To Smart City Command Center For 1 Year 1 Unit Fiber Optic Fusion Equipment - Fiber Optic Fusion Equipment - Fiber Alignment Core/cladding Motor Number 6 Motors Splicing Time 5s Heating Mode 15s, Can Be Customized According To The External Environment Fiber Type Single-mode Fiber (smf/g.652), Bif/g.657); Suitable For Single Mode, Multi-mode, Bare Fiber, Tail Fiber, Drop Cable, Jumper, Invisible Fiber Fusion; The Cladding Diameter 80-150μm Splicing Loss 0.02db(sm)、0.01db(mm)0.04db(ds/nzds) Splicing Mode Automatic Focusing Core Alignment, Conventional/high Precision Welding Splicing Way Automatic, Semi-automatic Opm Wavelength: 850nm、1300nm、1310nm、1490nm、1550nm、1625nm、980nm、1270nm、1577nm、1650nm/measurement Range: -50+26dbm Absolute Error: <0.3db (-50dbm ~+3dbm Range) Battery Capacity 7800mah Large Capacity Lithium Battery Charging Time ≤3.5; It Can Continuously Weld And Heat About 260 Cores Magnification 320x (x Or Y Axis Single Display) 200x (x And Y Axis Dual Display) Fiber Diameter Coating Diameter: 80-150μm/coating Diameter: 100-1000μm Cutting Length Coating Layer 250μm Below: 8-16mm/coating Layer 250-1000μm: 16mm Heat Shrink Tube 60mm、50mm、40mm、25mm Tensile Testing Standard 2n Display 5 Inch Tft Color Display Screen Return Loss Better Than 60 Db Product Protection Waterproof, Dustproof And Fall Proof Warranty :1 Year 44 Unit Fiber Patch Cord Single-mode 9/125 Sc/upc To Lc/upc - Fiber Patch Cord Single-mode 9/125 Sc/upc To Lc/upc - Fiber Patch Cord Single-mode 9/125 Sc/upcto Lc/upc3 Meter 44 Unit Fiber Patch Cord Single-mode Sc/upc To Sc/upc - Fiber Patch Cord Single-mode Sc/upc To Sc/upc - Fiber Patch Cord Single-mode Sc/upcto Sc/upc3 Meter 45 Unit Gigabit Rj-45 Surge Protector Arrester - Gigabit Rj-45 Surge Protector Arrester - Protects Your Ethernet Device From The Damage Of Lightning & Surge Gigabit 10/100/1000 Specification: Connectors: Rj-45 Material: Shielded Aluminum Alloy 44 Unit Grounding Bus Bar With Insulator - Grounding Bus Bar With Insulator - Grounding Bus Bar With Insulatorat Least 8 Way At Least 8x12mm² 2 Roll Grounding Cable Pure Copper Wire - Grounding Cable 4mm Pure Copper Wire Round Solid 100m Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 7 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 22 Unit Grounding Rod And Clamp Copper Plated - Grounding Rod And Clamp Copper Plated - "grounding Rod Full Set - (1pc Grounding Rod + 1 Pc Grounding Clamp) Size: Approximately 50cm Length X 0.9cm Diameter" 22 Unit Heavy Duty Surface Type Extension Outlet 4 Gang - Heavy Duty Surface Type Extension Outlet 4 Gang - Heavy Duty Surface Type Extension Outlet 4 Gang 15 Amperes Capacity/ Maximum 3,750watts 1 Lot Installation, Integrations And Configuration Of Outside Plant Equipment - Installation, Integrations And Configuration Of Outside Plant Equipment - Installation, Integrations And Configuration Of All Outside Plant Project Equipment In Outside Project Sites Outside Of The Smart City Command Center 1 Lot Installation, System Integrations And Configuration Of All Inside Plant Project Equipment - Installation, System Integrations And Configuration Of All Inside Plant Project Equipment In The Smart City Command Center Such As The Hikcentral Camera License, Integration To Existing Hikcentral Software And Integration Of Existing Cctv Cameras Into New Nvr 22 Unit Iot Box Panelbox Metal Enclosure (ip66,nema4 & 12) 500x300x200mm W/ 2 Fans And Fan Filter With Pole Mount Bracket X1 Heavy Duty Surface Type Extension Outlet 4 Gang Terminal Block Distribution 2 Input 4 Output Push-in Type 40 Unit Lpr Camera Arm Mount - Gi Pipe Extension Arm 1.5-3 Meters 40 Unit Lpr Camera Memory Card - Product Capacity Covering 128g The Storage Mediumis Tlc Particles Long Reading And Writing Times, Which Can Meet More Than 1000 Cycles Optimized For Long Time On-board Video Recording, Offering More Stable Reading And Writing Experience Operating Voltage 2.7v~3.6v Compatibility Sd 6.1 Working Life 1,000 Cycles Storage Medium Tlc Speed Class Write/read Speed 64gb:up To 35/100mb/s 128gb:up To 70/100mb/s256gb:up To 90/100mb/s Durability 10,000 Insertion/removal Cycles Uhs-i Sdr104 Type Sdxc 40 Unit Lpr Camera Vertical Pole Mount - Vertical Pole Mounting Bracket Installed On The Cross Bar Galvanized Steel Sheet And Steel Material With Surface Spray Treatment Can Be Used For New Bullet Camera Outdoor Greycolo Must Be Compatible With Cctv Camera 22 Roll Metal Flexible Conduit 1 Inch - Metal Flexible Conduit 1 Inch 30 Meters Per Roll 44 Unit Molded Case Circuit Breaker Mccb 30a - Molded Case Circuit Breaker Mccb 30a 220v 2 Pole Din Rail Mount Type 22 Unit Molded Case Circuit Breaker Mccb 63a - Molded Case Circuit Breaker Mccb 63a 220v 2 Pole Din Rail Mount Type 22 Unit Poe Switch Power Supply - Power Supply 48v 2a 96w With Us Plug Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature Page 8 Of 12 Republic Of The Philippines Bids And Awards Committee Baguio City (074) 300-6537/ (074)442-8795 Bid Form Cp No. 2024-231 Bidding December 10, 2024 Circular Proposal No. Date Prepared The City Government Of Baguio, Through Its Bids And Awards Committee Desires To Purchase The Articles Listed Below Seven (7) Months Upon Receipt Of Contract Award. Item Qty Unit Particulars Abc (php) Unit Price Total (php) 22 Unit Residual Current Circuit Breaker 63a 220v - Residual Current Circuit Breaker 63a 220v With Grounding/earthing 2 Pole Din Railmount Type 44 Unit Sfp+ Module Lc Connector Type - Gigabit Single-mode Wdm Bi-directional Sfp Module Spec: Lc Connector, Tx:1550nm/rx:1310nm, Single-mode, 20 Km 7 Roll Solidwire Awg#12 - Solidwire Awg#12 75m Per Roll Use For Termination Inside Iot Box 7 Roll Solidwire Awg#16 - Solid Wire Awg#16 75m Per Roll Use For Termination Inside Iot Box 66 Unit Terminal Block Distribution 2 Input 4 Output - Terminal Block Distribution 2 Input 4 Output Push-in Type This Is A Lot Bidding, Partial Bids Are Not Allowed Please Indicate Brands Of Offers And Attach Complete Technical Brochures In The Eligibility And Technical Proposal Please Indicate Unit Prices Of Offers In The Financial Proposal Bidders Must Possess Valid Mayor's/business Permit With A Relevant Line Of Business For Use Of Cmo Mitd Under Pr No. 1 Please Refer To Attached Terms Of Reference In The Associated Components Please Refer To Attached Bid Instruction For The Eligibility Requirements, Technical Proposal And Financial Proposal Format. Drop Your Documents In The Bidding Box Located At The City General Services Officel, City Hall, Baguio. The Opening Of Bids By The Bids And Awards Committee Shall Be At The Cdrrmc Bldg., Lower Rock Quarry, Baguio City, January 10 , 2025 9:30 Am Coa Representative, Two (2) Observers From The Private Sector And Non-governmentagency As Well As Interested Bidders. Atty. Augustin P.laban Iii Chairperson, Bids & Awards Committee Please Read Conditions At The Back Hereof. Non-compliance Of Any Of The Provisions Thereof Will Invalidate One's Bid/quotation. Bidders Shall Fill The Blank Spaces Below. Respectfully Returned To The Bids And Awards Committee, Baguio, With The Prices Quoted. All Conditions Set At The Back Hereof Are Hereby Accepted. The Required Good Faith Deposit Is Hereby Enclosed In The Amount Of Php ______________________________________ In Cash, Check Or Surety Bond. My Business Is _________________________________________________ Which Is Licensed Under Business Permit No./ Mayor's Permit No.____________ Issued On ________________________________. My Nationality Is ________________________. Please Refer To The Bid Conditions At The Back Name Of Establishment Bidder's Signature
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Civil And Construction...+2Others, Building Construction
United States
Closing Date7 Feb 2025
Tender AmountRefer Documents
Details: This Is Not A Request For Proposal. This Is A Request For Standard Form (sf) 330 Architect-engineer Qualifications Packages Only. All Information Needed To Submit Sf 330 Documents Is Contained Herein. No Solicitation Package, Technical Information, Or Bidder/plan Holder List Will Be Issued. The Government Will Not Pay, Nor Reimburse Any Costs Associated With Responding To This Request. The Government Is Under No Obligation To Award A Contract As A Result Of This Announcement. general Information veterans Health Administration (vha) Regional Procurement Office West (rpow) Network Contracting Office 20 (nco20) Is Seeking Sources And Intends To Award A Firm Fixed Price Design Contract For Architect-engineering (a-e) Services For The Development Of Complete Construction Documents, Which Include Working Drawings, Specifications, And Reports, And Construction Period Services For Project # 463-25-101 Generator Physical Security Upgrades At The Alaska Va Healthcare System Outpatient Clinic Located At 1201 N Muldoon Rd, Anchorage, Ak 99504-6104. The A-e Services Contract That Is Anticipated To Be Awarded Will Be Procured In Accordance With The Selection Of Architects And Engineers Statute [formerly Known As The Brooks Architect Engineer Act], Federal Acquisition Regulation (far) Subpart 36.6 Architectural And Engineering Services, Va Acquisition Regulation (vaar) 836.6, And Va Acquisition Manual (vaam) M836.6 Architect-engineer Services. In Accordance With Far 36.209, Construction Contracts With Architect-engineer Firms, No Contract For The Construction Of A Project Shall Be Awarded To The Firm That Designed The Project Or Its Subsidiaries Or Affiliates, Except With The Approval Of The Head Of The Agency Or Authorized Representative. project Information this Project Is A 100% Set-aside For Service-disabled Veteran-owned Small Business (sdvosb) Concerns. The Naics Code For This Procurement Is 541330 Engineering Services And The Annual Small Business Size Standard Is $25.5m. A Full Design Team Is Required To Complete This Project. The Va Expects To Award The Anticipated A-e Contract Approximately Early March 30, 2025. the Anticipated Period Of Performance For Completion Of Design Is 164 Calendar Days After Notice Of Award (noa). The Vaar Magnitude Of Construction Is Between $695,000.00 And $1,000,000.00. Please Note That The 164 Calendar-day Period Of Performance For The Design Completion Begins With The Issuance Of The Noa And That A Notice To Proceed (ntp) Will Not Be Issued For The Completion Of A Design Project. submission Requirements: the Below Information Contains The Instructions And Format That Must Be Followed For The Submission Of The Sf 330 Statement Of Qualifications: submit One (1) Sf 330 Statement Of Qualifications To Contract Specialist Melita Bernardo At Nco20aesf330@va.gov And Melita.bernardo@va.gov. This Must Include Parts I And Ii And Any Applicable Attachments. the Submission Must Include The Sf 330, Architect-engineer Qualifications Form Is Available Online At: Http://www.cfm.va.gov/contract/ae.asp Or Https://www.gsa.gov/system/files/sf330-21.pdf the Sf 330 Submission Is Due By February 7, 2025, 3:00pm (pst). the Sf 330 Must Be Submitted In One Email And Have A File Size No Larger Than 5 Mb. No Hard Copies Will Be Accepted. the Subject Line Of The Email Must Read: Sf 330 Submission 36c26025r0045 Project 463-25-101, General Physical Security Upgrades.
the Sf 330 Submission Must Not Exceed A Total Of 50 Pages. This Includes Title Page, Table Of Contents, And Any Other Relevant Information. Any Pages Submitted By An Offeror That Exceed The Limit Will Not Be Considered During The Evaluation. Each Page Must Be In Arial Size 12 Font, Single Spaced. Part Ii Of The Sf 330 And Any Cpars Or Ppqs Will Not Count Toward The Page Limitation. a Ppq Obtained For Another Sf 330 Submission May Be Submitted For This Project. However, If Significant Portions Of The Project Have Been Completed Since The Ppq Was Filled Out, A New Ppq Should Be Submitted To Accurately Assess The Project. firms Must Include The Following Information In Section B Of The Sf 330 Submission: sam Unique Entity Identifier tax Id Number cage Code primary Point Of Contact S Email Address And Phone Number all Questions Must Be Submitted To Melita.bernardo@va.gov With The Subject Line Sf 330 Questions - 36c26025r0045 Project 463-25-101 Generator Physical Security Upgrades. The Cutoff For Question Submission Is January 17, 2025, 3:00pm Pst. Questions Will Be Answered Through Amendment To The Notice Posted To Contract Opportunities At Sam.gov. this Procurement Is A 100% Set-aside For Sdvosb Concerns. Offers Received From Other Than Sdvosbs Will Not Be Considered. Offerors Must Be Certified As Sdvosbs By The U.s. Small Business Administration (sba) And Visible In The Veteran Small Business Certification (vetcert) Database (https://veterans.certify.sba.gov/) At The Time Of Sf 330 Submission, Written Response Submission, And Award. Failure To Be Certified In The Vetcert Database At These Times Will Result In The Offeror Being Deemed Ineligible For Award. all Joint Ventures Must Be Sba Certified At The Time Of Sf 330 Submission, Written Response Submission, And Award And Must Submit Agreements That Comply With 13 Cfr 128.402 Prior To Contract Award. all Prime Firms Must Meet The Naics Code Requirement Specified In This Notice. The Contracting Officer Will Verify The Naics Code In Vetcert. Failure To Meet The Naics Code Requirement May Result In The Rejection Of The Sf 330 Submission. sf 330 Submissions Received After The Date And Time Specified Will Not Be Considered. Late Proposal Rules Per Far 15.208 Will Be Followed For Late Submittals. firms Not Providing The Required Information May Not Be Evaluated. All Information Must Be Included In The Sf 330 Submission Package. it Is The Offeror S Responsibility To Check The Contract Opportunities Website At Sam.gov For Any Revisions To This Announcement Prior To Submitting Their Sf 330. a-e Selection Process firms Who Timely Submit Sf 330s In Response To This Announcement, And In Accordance With Submission Requirements, Will Be Considered For Evaluation. The Selection Will Be Made As Follows: sf 330s Will Be Evaluated In Accordance With The Primary Selection Criteria As Stated In This Notice. These Evaluations Will Determine The Most Highly Qualified Firms For This Particular Requirement. in Accordance With Far 36.602-3(c), At Least Three Of The Most Highly Qualified Firms Will Then Be Notified Of The Government S Intent To Hold Discussions. Firms That Were Not Selected For Discussions Will Be Notified At This Time. In Accordance With Far 36.607(b), Any Requested Debriefings Of Successful And Unsuccessful Firms Will Be Held After Final Selection Has Taken Place And Will Be Conducted, To The Extent Practicable, In Accordance With 15.503, 15.506(b) Through (f), And 15.507(c). Note That 15.506(d)(2) Through (d)(5) Do Not Apply To Architect-engineer Contracts. discussions Will Be Held With Top Three Firms In The Form Of Written Responses. The Firms Invited To Participate In Discussions Will Be Notified By Contract Specialist Or Contracting Officer By Email With Detailed Instructions That Will Include Questions Or Topics To Address. following The Completion Of Discussions, The Firms Will Be Evaluated And Ranked Based On The Primary And (if Necessary) Secondary Selection Criteria. The Final Evaluation And Ranking Will Consider The Sf 330 Submission For Each Firm, As Well As Additional Information Obtained Via Discussions. The Highest Rated Firm Will Be Selected To Receive The Solicitation And Engage In Negotiations. the Solicitation Will Be Issued To The Highest Rated Firm As A Request For Fee Proposal (rfp). All Sow Attachments And Site-specific Documentation Will Be Provided To The Highest Rated Firm With The Rfp. A Site Visit May Be Authorized During The Negotiation Process. an Award Will Then Be Made As Long As The Negotiation Of Rates And Hours Leads To A Fair, Balanced, And Reasonable Determination Of The Final Contract Price. If Negotiations With The Highest Rated Firm Are Unsuccessful, The Firm Will Be Notified That Negotiations Have Been Terminated. Negotiations Will Then Be Initiated With The Next Highest Rated Firm, And So On Until Award Can Be Made Or This Announcement Is Cancelled. primary Selection Criteria: firms Responding To This Notice Will Be Evaluated And Ranked Using The Primary And Secondary Selection Criteria Listed Below. The Factors Are Listed In Descending Order Of Importance. The Evaluation Will Consider How Each Factor Is Addressed And How It Is Formatted To Coincide With The Selection Criteria. selection Criteria 1, Professional Qualifications (sections C Through E): The Evaluation Will Consider The Professional Qualification Necessary For Satisfactory Performance Of Required Service. The Evaluation Shall Consider The Specific Experience (minimum Of Five Years) And Qualifications (i.e., Education, Training, Registration, Certifications, Overall Relevant Experience, And Longevity With The Firm As Full-time Employees) Of Personnel Proposed For Assignment To The Project, And Their Record Of Working Together As A Team When Evaluating Professional Qualifications. The Lead Designer In Each Discipline Must Be Registered But Does Not Have To Be Registered In The Particular State Where The Project Is Located. The A-e Shall Demonstrate They Are Able To Sign And Stamp Each Drawing By Individuals Licensed In Any State In The United States For The Key Positions Listed Below. Provide Professional License Numbers And/or Proof Of Licensure.
a Resume For Each Of These Key Positions Must Be Provided Via Section E Of The Sf330. Key Positions And Disciplines Required For This Project May Include Among Others:
architect (leed Certified) cadd Technician civil Engineer cost Estimator electrical Engineer environmental Engineer fire Protection Engineer geotechnical Engineer industrial Hygienist life Safety Engineer mechanical Engineer physical Security Specialists plumbing Engineer project Manager quality Assurance structural Engineer offer Must Include The Following Statement Of Sdvosb Compliance On The Cover Page When Submitting The Personnel Proposed To Perform The Work Under This Requirement: I [signatory Authority] ___________________, [company Or Joint Venture] __________________, Certify That The Sdvosb Prime Contractor Will Not Pay More Than 50% Of The Amount Paid By The Government To The Prime For Contract Performance To Firms That Are Not Certified Sdvosbs By The Small Business Association S Veteran Small Business Certification (vetcert) In Compliance Of Va Acquisition Regulation (vaar) 852.219-75. the Information Provided In Sections C Through E Of The Sf 330 Will Be Used To Evaluate This Evaluation Factor. Do Not Include This Information In Section H, Unless It Is Pertinent To Support The Information Listed In The Other Sections. selection Criteria 2, Specialized Experience And Technical Competence (sections F, G, And H):
the Evaluation Will Consider Specialized Experience And Technical Competence In Design And Construction Period Services For Demolishing And Regrading Corridor. Provide Information For Example Projects Which Best Illustrate The Proposed Team S Experience And Competencies For This Contract. Submissions Shall Include Information Regarding Experience And Competence In: identify All Existing Utilities Located Within And Beneath The Existing Walkway.
reroute Active Utilities Below Ground.
demolish All Unused Utilities Back To The Source And To The Destination As Far As Practicable.
abate All Asbestos And Lead As Necessary.
remove Walkway In Its Entirety.
ensure All Affected Buildings Have Abaas Compliant Access Throughout And At The Conclusion Of The Project.
provide Necessary Site Or Building Modifications And Equivalencies To Address Any Life Safety Violations Created By The Removal Of The Corridor.
where Practicable, Expose And Restore Original Decorative Railings Concealed Within The Corridor Walls.
provide Improvements To The Site Vacated By The Corridor, Such As Landscaping And Irrigation, Site Lighting, Sidewalks, Or Other Solutions As Determined By The Project Team. coordinate Final Design Conditions With The Future Site Plan, By Others, To Minimize Work Installed Under This Project That Would Interfere With Or Be Destroyed In The Implementation Of The Site Plan. other Specialized Experience Includes Experience In Critical Path Scheduling, Fire Protection, Seismic Design, Construction Infection Control Protocols, Energy Conservation, Transition, Pollution Prevention, Waste Reduction, Use Of Recovered Materials, And Sustainable Design Practices. submissions Shall Include The Following Information For Example Projects: project Title, Location And Detailed Narrative Describing The Scope Of Services Provided Including The Type Of Work Performed By The Offeror And Its Role In The Project I.e., Prime Contract, Teaming Partner, Or Subcontractor. project Owner, Owner S Point Of Contact Including Telephone Number And Email Address. services & Deliverables Provided Under The Contract Or Task Order. period Of Performance, Including Start And Completion Dates total Dollar Value Of The Project contract Number Associated With The Project. submissions Shall Include No More Than Five (5) And No Less Than Three (3) Recent And Relevant, Government And Private Experience, Example Projects, Similar In Size, Scope, Construction Features And Complexity, Which Clearly Illustrate Experience And Competencies Listed Above And In Other Portions Of This Solicitation. Recent Is Defined As Services Provided In The Five (5) Years Prior To The Closing Date Of This Solicitation. Relevant Is Defined As Projects, Within The United States, Its Territories, Or Possessions, Requiring Tasks Identified In This Solicitation. Similar Complexity Is Considered Projects Of An Operational, Construction, Or Design Likeness To The Work Covered In This Solicitation. two (2) Of The Example Projects Must Have Construction Completed Or Construction Substantially (50%+) Complete. submit Example Project Information In Section F Of The Sf 330. section G Of The Sf 330 Will Be Used To Evaluate The Prior Experience Of The Prime Firm And Any Key Subcontractors Working Together On The Provided Example Projects. the Evaluation Will Also Consider Narratives Addressing The Following Topics For The Offeror, And Key Consultants, In Section H Of The Sf 330: the Management S Approach. the Coordination Of Disciplines And Subcontractors quality Control Procedures, And familiarity With Va Design Guides/manuals, Master Specifications, And Other Applicable Standards. the Narratives Should Clearly Illustrate How Each Of The Topics Were Addressed. Re-stating Or Reiterating This List Or The Scope Of Work In Section H Will Not Be Sufficient.
narratives Submitted In Section H Of The 330, Shall Not Exceed One (1) Page In Length For The Offeror And Each Key Consultant. The Narrative Submissions Shall Not Exceed Ten (10) Pages Total For This Criterion. selection Criteria 3, Capacity (section H) the Evaluation Will Consider The Team S Plan And The Evaluation Will Consider The Firm S Ability To Meet The Schedule Of The Overall Project, As Well As The Available Capacity Of Key Disciplines To Perform The Work In The Required Time. provide The Available Capacity Of Key Disciplines By Providing Current Project Workload, Inclusive Of All Projects Awarded During The Previous 12 Months And The Full Potential Value Of Any Current Indefinite Delivery Contracts. offeror Shall Clearly State Their Available Capacity Presenting Workload Percentages For The Key Disciplines And/or Team Members. Also, The Offeror Must Provide The Completion Percentages And Expected Completion Date For Projects Awarded In The Previous 12 Months. The Information For This Factor Shall Be Provided In Section H Of The Sf 330. Please Ensure The Capacity Applies Toward The Team/personnel Provided In The Sf 330. selection Criteria 4, Past Performance (section H) the Evaluation Will Consider The Firm S Past Performance On Contracts With Government Agencies And Private Industry In Terms Of Cost Control, Quality Of Work, And Compliance With Performance Schedules. past Performance Will Be Evaluated For All Projects Provided In Section F. The Contractor Performance Assessment Rating System (cpars) Database Will Be Reviewed To Evaluate The Projects That Have A Cpars Entry. Cpars Are Not Required To Be Submitted With The Sf330 Submission. The Contract Number For The Project Must Be Submitted With Each Project In Section F So Cpars Can Be Reviewed In The Database. for Any Project That Does Not Have Cpars Data Available, A Past Performance Questionnaire (ppq) Is Required To Be Submitted With The Sf330. The Ppq Should Be Rated And Signed By The Evaluator. In The Event That A Firm Does Not Receive A Requested Complete Ppq From An Evaluator Prior To The Time For Submission, The Firm Shall Submit The Partially Completed Ppq With Section 1 And The Evaluator Information In Section 2 Completed. Ensure A Poc Is Listed With The Project Title/contract Number. The Va Will Make Reasonable Attempts To Contact The Poc Upon Submission For Ppq Completion. evaluations May Also Include Additional Performance Related From The Firm, Customer Inquiries, Government Databases, Publicly Available Sources, And Additional Projects In Cpars. The Government Reserves The Right To Contact Any Poc Listed On A Cpars Report Or Ppq. failure To Provide Requested Data, Accessible Points Of Contact, Or Valid Phone Numbers May Result In A Firm Being Considered Less Qualified. All Projects Provided In The Sf 330 Must Be Completed By The Office/branch/individual Team Member Performing The Work Under This Contract. The Information For This Factor Shall Be Provided In Section H Of The Sf 330. for Ppqs, Please Utilize The Attached Ppq Document Only. Completed Ppqs Should Be Incorporated Into The Sf 330 Directly. Ppqs Should Not Be Submitted Separately To Nco20 Directly. Any Ppqs Will Not Be Counted Towards The Page Limitations For This Submission. However, Any Narratives Provided For Past Performance In Section H Shall Not Exceed Two (2) Pages In Length And Will Be Counted Toward The Total Submission Page Limit. selection Criteria 5, Knowledge Of The Locality (section H), the Evaluation Will Consider The Knowledge Of The Locality, Including Specific Knowledge Of Local Conditions Or Project Site Features, Such As Geological Features, Climatic Conditions, Working With And Local Construction Methods Or Local Laws And Regulations Of The Area Of Anchorage, Ak. The Information For This Factor Shall Be Provided In Section H Of The Sf 330. note That The Intent Of This Factor Is To Showcase A Firm S Understanding Of The Project Site And Locality, And Not Where The Firm Is Located, How Far Away The Firm/branch Office Is From The Site, And How They Would Travel To The Site. Information Related To The Firm S Location Shall Be Provided In Section H Under Secondary Selection Criterion Factor 1, Geographic Location. See Below. selection Criteria 6, Experience In Construction Period Services, (section H) the Evaluation Will Consider Experience In Construction Period Services (cps) Necessary For Performance Of This Contract. Submissions Shall Provide Information Which Clearly Illustrates Cps Experience In The Following: solicitation Support Services professional Field Inspections During The Construction Period, Both Scheduled And Emergent coordination With Commissioning Requirements/commissioning Services review Of Construction Submittals For Design Conformance, Variance, And Applicable Code/standard Compliance support In Answering Requests For Information (rfi) During The Construction Period support Of Construction Contract Changes To Include Drafting Statements Of Work And Cost Estimates maintaining A Comprehensive Submittal Log Inclusive Of Material Data, Shop Drawings, Certifications, Etc. providing Timely And Complete Responses To Requests For Information providing Supporting Documentation (statements Of Work, Cost Estimates, Technical Reports, Etc.) For Construction Modifications providing Record Drawing Documentation process For Correcting Design Errors/omissions Identified During Construction attendance At Pre-bid, Post-award, And Commissioning Kick Off Construction Project Conferences providing Minutes Of Weekly Construction Meetings Throughout The Duration Of Construction site Visits During Construction Both Scheduled And Emergent ensuring Compliance With The Design Drawings And Specifications preparation Of Site Visit Reports generation Of Punch-list Reports review Of Construction Project Modifications For Cost And Technical Acceptability attendance And Participation During The Final Acceptance Inspection preparation Of Record Drawings Of The Completed Construction Project Based On The Construction Contactor S As-built Drawings maintenance Of Rfi Logs attendance At Weekly Conference Calls providing Minutes Of Meetings Between The Ae, Va, And Contractors pre-final Inspection Site Visits production Of As-built Documentation the Information For This Factor Shall Be Provided In Section H Of The Sf 330. secondary Selection Criterion: Geographic Location. location Of The Firm, As Measured By The Driving Distance (miles) Between The Offeror S Principal Business Location And The Alaska Va Healthcare System At 1201 N Muldoon Rd, Anchorage, Ak. Determination Of The Mileage Will Be Based On Google Maps. (https://www.google.com/maps/dir/). *the Secondary Selection Criterion Is Used As A Tiebreaker, If Necessary, In Ranking The Most Highly Qualified Firms Following The Completion Of Discussions. The Secondary Selection Criterion Will Not Be Applied When Determining A Firm S Sf 330 Submission Highly Qualified Or Not Highly Qualified.
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Civil And Construction...+1Others
United States
Closing Date5 Feb 2025
Tender AmountRefer Documents
Details: Presolicitation Notice presolicitation Notice presolicitation Notice
*=required Field
presolicitation Notice this Pre-solicitation Notice Is Not A Request For Proposal. All Information Needed To Submit Sf330 Documents Are Contained Herein. No Additional Solicitation Package Or Technical Information Will Be Issued. project: 534-23-106 Ae Upgrade Mechanical Systems Phase 2 work Location: Ralph H. Johnson Health Care System, Charleston, Sc estimated/target Completion Period: 360 Calendar Days After Award.
construction Magnitude: Between $5,000,000 And $10,000,000 naics: 541310 Architectural Services small Business Standard: $12.5 Million set-aside: 100% Service-disabled Veteran-owned Small Business (sdvosb)
site Visits Will Not Be Arranged During This Phase. the Anticipated Award Date Of The Proposed A-e Contract Is On Or Before September 01, 2025. sf 330 Date Of Receipt/due Date: Interested Firms Having The Capabilities To Perform This Work Must Submit One (1) Electronic Sf330 And Attachments If Any, No Later Than
(nlt) 10:00 Am (est) February 5, 2025. project Overview:
provide Professional Architect/engineer (a/e) Services Necessary For A Complete Design To Replace The Main Laboratories Air Handling Unit, Correct Hvac And Mechanical Systems Deficiencies, And Provide Compliant Temperature Control And Air Change Requirements By Areas As Defined In The Limits Of Work. Additional Scope Includes Assessment And Replacement Of Isolation Exhaust Systems And Steam-to-hot Water Heat Exchangers And Associated Pumps Located In Penthouse, Specialty Clinics, And Eye Specialty Clinic. The Project Will Include Temporary Hvac Considerations And Phasing To Enable Continued Operations. sdvosb Set-aside:
this Requirement Is A 100% Set-aside For Service-disabled Veteran-owned Small Businesses Under The Authority Of 38 U.s.c. 8127(d). To Be Eligible For Award The Sdvosb You Must Be Considered Small Under The Relevant Naics Code. Sdvosb Contractors Must Be Verified And Viewable In Small Business Administration Veteran Small Business Certification (vetcert) Database Https://veterans.certify.sba.gov Prior To Submission And Prior To Award Of Contract With Vaar 804.1103-70. Status As A Qualified Sdvosb Concern Is Under The Authority Of 38 Cfr Part 74 In Accordance With The Va Acquisition Regulation (vaar) Part 819. Any Person, Persons, Or Business Entity Suspected Of Misrepresenting Itself For The Purpose Of Securing A Government Contract May Be Criminally Investigated And Prosecuted For Fraud Against The United States Of America. Parties Found Misrepresenting Their Status Also Risk Debarment From Further Government Contracts. Eligible Sdvosb Concerns Must Also Be Registered At The Following Websites: system For Award Management (sam): Https://www.sam.gov/ vets100/100a Report Must Be Complete: Http://www.dol.gov/vets/vets4212.htm important Notice: Prior To Submitting A Package Under This Sdvosb Set- Aside Solicitation; Offerors Must Apply For And Receive Verification From The Small Business Administration In Accordance With 38 Cfr Part 74 And Vaar 819.70 By Submission Of Documentation Of Veteran Status, Ownership, And Control Sufficient To Establish Appropriate Status. All Offerors Are Urged To Contact The Sba And Submit The Required Documents To Obtain Verification Of Their Sdvosb Status If They Have Not Already Done So. for A Service-disabled Veteran Owned Small Business (sdvosb) To Be Considered As A Prospective Contractor, The Firm, Including Joint Ventures, Must Be Verified And Registered In The Small Business Administration Veteran Small Business Certification (vetcert) Database (https://veterans.certify.sba.gov) And Registered In The System For Award Management (sam) Database (www.sam.gov) At Time Of Submission Of Their Qualifications. Failure Of A Prospective Sdvosb To Be Verified By The Center For Veterans Enterprise (cve) At The Time The Sf 330 Is Submitted Shall Result In Elimination From Consideration. All Joint Ventures Must Be Cve Verified At Time Of Submission And Submit Agreements That Comply With 13cfr 125.15 Prior To Contract Award. sf 330 Selection Criteria: Evaluation Of Submission Requirements And Selection Criteria Are Provided Below And Listed In Relative Order Of Importance. note: Failure To Meet An Acceptable Submission Requirements For Each Criteria Will Result In The Entire Submission Being Denied For Further Evaluation. phase 1 Submission Requirements objective Scoring: Acceptable Submissions Meets All Submission Requirements Unacceptable Submission Fails To Meet At Least One Submission Requirement specialized Experience And Technical Competence In The Type Of Work Required.
submission Requirements: sf 330 Information Shall Be Provided Per The Latest Format From The Gsa Library Located At Https://www.gsa.gov/forms-library/architect-engineer-qualifications. complete Using Blocks F. And H. Of The Sf330 Form. Complete Block F. For Each Relevant Project. Complete Block H. Summary Sheet For The Offeror And Each Key Consultant; Each Summary Sheet Shall Be Not More Than One (1) Page In Length. submit No More Than Five (5) Projects Similar To Required Work In The Solicitation From The Date The Solicitation Closes To Five (5) Years Prior; at Minimum, Three (3) Projects Must Be Construction Complete Or Construction Substantially (50%+) Complete; projects/data Submitted Shall Be Projects With Total Construction Costs Of $6,000,000 And Greater; projects May Include Federal, State, Or Local Government, As Well As Private Industry Projects. Offerors Are Responsible For Providing Project Description And Applicable Information In Sufficient Detail To Permit Evaluation Of Project Relevancy Versus These Minimum Requirements. past Performance On Contracts With Government Agencies And Private Industry In Terms Of Cost Control, Quality Work, And Compliance With Performance Schedules.
submission Requirements: complete A Summary Sheet Using Block H. Of The Sf 330 Describing The Offeror S Past Performance. The Summary Sheet Shall Be Not More Than Two (2) Pages In Length. provide The Contractor Performance Assessment And Reporting System (cpars), Interim And Final Reports, For Each Submitted Federal Entity Project Under Specialized Experience Criteria, Above. If A Cpars Is Not Available, Provide A Ppq. if A Relevant Project Submitted Under Specialized Experience Criteria Does Not Have A Cpars Because It Is A Non-federal Entity Project, Provide A Past Performance Questionnaire (ppq). cpar And Ppq Reports Will Not Count Towards Page Limitations. professional Qualifications Necessary For Satisfactory Performance Of Required Services.
submission Requirements: complete Using Block E. Of The Sf 330. Submit Personal Resumes And Relevant Information For Key And Responsible Personnel. Block E. Shall Be Not More Than One (1) Page In Length Per Individual. the Offeror Shall Have A Professional Engineer, Currently Registered In Any Us State Or Territory Of The United States, Knowledgeable In Their Registered Design Discipline, To Be The Lead Designer Responsible For Reviewing And Approving Design Submissions. the Offeror Shall Have A Professional Engineer, Qualified And Knowledgeable Of South Carolina State And Local Regulations, Be The Lead Designer Responsible For Reviewing And Approving Design Submissions And Facilitating Permit Documentation (depending On The Nature Of The Design I.e. Environmental, Hazardous Material Abatement, Stormwater, Etc.). key Personnel To Provide Qualifications To Meet This Criterion Include Principal(s), Project Manager(s), Key Consultants, Individuals Responsible For Implementation Of The Design Qa/qc Plan, Licensed Asbestos Inspector, Physical Security Specialist, Life Safety Specialist, And Other Individuals That Are Responsible Or Accountable For Design Submissions And Regulatory Compliance. physical Security Subject Matter Experts Shall Meet The Requirements Of Section 10.1.5 Of The Physical Security & Resiliency Design Manual. experience In Construction Period Services.
submission Requirements: complete Using Block H. Of The Sf 330. Provide A Narrative That Describes The Offeror S Performance Completing Construction Period Services (cps) For Construction For Each Submitted Project Under Specialized Experience Criteria, Above. Narrative Shall Be Not More Than Two (2) Pages In Length. capacity To Accomplish The Work In The Required Time.
submission Requirements: complete Using Block H. Of The Sf 330. Provide A Narrative That Describes The Offeror S Work Capacity. Narrative Shall Be Not More Than One (1) Page In Length. location In The General Geographical Area Of Charleston, Sc, And Knowledge Of The Locality Of The Ralph H. Johnson Va Facility:
submission Requirements: complete Using Block H. Of The Sf 330. Provide A Narrative That Describes The Offeror S Experience In The Charleston, Sc Geographical Area. Narrative Shall Be Not More Than One (1) Page In Length. the Extent To Which Potential Contractors Identify And Commit To The Use Of Service-disabled Veteran-owned Small Businesses, Veteran-owned Small Businesses, And Other Types Of Small Businesses As Subcontractors:
submission Requirements: complete Using Block H. Of The Sf 330. Provide A Narrative That Discusses The Offeror S Approach. Narrative Shall Be Not More Than One (1) Page In Length. offerors Shall Complete And Submit The Following Statement In Block H. : I [signatory Authority], Of [offeror Company Or Joint Venture] Certify That The Team Proposed To Perform Under This Requirement Demonstrates The Capability Of 50% Sdvosb Performance In Compliance Of 48 Cfr 852.219-10 . phase 2 Evaluation Of Selection Criteria specialized Experience And Technical Competence In The Type Of Work Required. basis Of Evaluation: specialized Experience Pertains To The Types, Size, Volume, Budget, And Complexity Of Work Previously Or Currently Being Performed By The Offeror That Is Comparable To The Work Covered By This Solicitation. Specialized Experience May Also Include Unique Conditions, Considerations, Or Circumstances Encountered That Are Relevant To This Solicitation. specialized Experience Does Not Include Overseas Offices For Projects Outside The United States, Its Territories, Or Possessions; Nor Does It Include Subsidiaries That Are Not Normally Subject To Management Decisions, Accounting, And Policies, Or A Holding Or Parent Company Or An Incorporated Subsidiary That Operates Under A Firm Name Different From The Parent Company. technical Competence Includes Construction And Design Projects Similar In Project Scope, Size, Construction Features, Dollar Value, And Complexity Of That Listed In The Solicitation. Technical Competence Also Includes Experience In Energy Conservation, Pollution Prevention, Waste Reduction, And The Use Of Recovered Materials. similar Complexity Is Considered Projects Of An Operational, Construction, Or Design Likeness To The Work Covered In The Solicitation. specific Emphasis Of Experience And Technical Competence Shall Be Geared Towards Fire Protection, Seismic Design/retrofit, Physical Security Resilience And Design, Healthcare Design/planning, Building Automatic System Design, And Mechanical/electrical System Design. past Performance On Contracts With Government Agencies And Private Industry In Terms Of Cost Control, Quality Work, And Compliance With Performance Schedules. basis Of Evaluation: past Performance Is A Measure Of The Degree To Which An Offeror Satisfied Its Customers Needs And Requirements And Compliance With Applicable Codes, Standards, Laws, And Regulations. The Evaluation Of Past Performance Will Include But Is Not Limited To: the Customer S Assessment Of The Offeror's Commitment To Customer Satisfaction; timely Delivery Of Quality Work; the Offeror's Record Of Conforming To Contract Requirements And Applicable Codes, Standards, Laws, And Regulations; successful Implementation Of A Quality Control Plan And Quality Control Procedures; addressing Design Errors/omissions Timely; adherence To Approved Schedules; And, history Of Timely And Professional Communication And Cooperative Behavior. include Information On Problems (errors/omissions) Found, How The Problems Were Corrected, And The Impacts To The Successful Completion Of The Project (time Delays, Cost Impacts, Design Modifications, Etc.). provide Information Supporting Favorable Cost Control, Quality Of Design Submissions, And Schedule Compliance. include A Discussion On The Offeror S Record Of Significant Claims For Improper Or Incomplete Design Services. higher Ratings May Be Given For Work Performed On Va Medical Center Campuses. adjectival Rating: offeror Risks Receiving A Lower Rating If Fewer Than Three (3) Ppqs Are Provided Or If The Ppqs Were Not Completed By Project Point Of Contact. failure To Demonstrate Proven Competence To Perform Projects With Similar Requirements To The Requirements Of The Solicitation May Be Considered Ineligible For Award. if No Cpars Or Ppqs Are Submitted Or Responses To Requests Were Not Provided, The Rating Shall Not Be Higher Than Satisfactory . professional Qualifications Necessary For Satisfactory Performance Of Required Services. basis Of Evaluation: evaluation Of Professional Qualifications Will Include But Is Not Limited To The Subjective Assessment Of The Offeror's Individual Resumes. the Offeror Shall Describe And/or Depict Which Projects And How Well Key Personnel Of The Design Team Have Worked Together. higher Ratings For This Criterion May Be Given When The Offeror's Specific Personnel Demonstrate Relevant Credentials, Such As Involvement And Degree Of Involvement In Professional Organizations, Research/publications, Code/standard Body Involvement, Etc. adjectival Scoring: offerors Unable To Demonstrate Professional Qualifications Necessary To Perform Designs May Be Considered Ineligible For Award. experience In Construction Period Services. basis Of Evaluation: experience In Construction Period Services To Include Professional Field Inspections During The Construction Period, Review Of Construction Submittals, Support In Answering Requests For Information During The Construction Period, And Support Of Construction Contract Changes To Include Drafting Statements Of Work, And Cost Estimates Shall Be Included As An Evaluation Criterion When Construction Period Services Is Included In The Statement Of Work For A-e Services. evaluation Of The Offeror S Knowledge, Skills, And Abilities To Complete Necessary Cps To Support Successful Project Completion. provide A Narrative Describing The Below Services, But Not Limited To: professional Field Inspections, Both Scheduled And Emergent; maintaining A Comprehensive Submittal Log Inclusive Of Material Data, Shop Drawings, Certifications, Etc.; review Of Construction Submittals For Design Conformance, Variance, And Applicable Code/standard Compliance; providing Timely And Complete Responses To Requests For Information; providing Supporting Documentation (statements Of Work, Cost Estimates, Technical Reports, Etc.) For Construction Modifications; providing Record Drawing Documentation; process For Correcting Design Errors/omissions Identified During Construction; And, other Requirements Defined Under Cps In The Statement Of Work. capacity To Accomplish The Work In The Required Time. basis Of Evaluation: identify The Offeror S Past, Present And Projected Future Workload, Including Va Contracts Over The Previous 12 Months. describe The Offeror S Capacity To Incorporate This Solicitation S Work While Meeting Prescribed Dates For Current Workload. Each Key Team Member To Include % Of Available Capacity To Take On New Projects. evaluation Of This Factor Will Be An Assessment Of The Offeror S Ability To Complete Design Documents Within The Period Of Performance And Meet Solicitation Requirements. data Is Acceptable In Tables Or Charts. capacity < 25% Shall Be Rated Not Greater Than Satisfactory. higher Ratings May Be Given For This Criterion When Information Provided Exceeds The Minimum Requirements. location In The General Geographical Area Of Charleston, Sc, And Knowledge Of The Locality Of The Ralph H. Johnson Va Facility: basis Of Evaluation: offerors Will Be Subjectively Evaluated Based On Their Knowledge (and The Knowledge Of Subcontractors) Of Unique Conditions Or Variables, Such As Familiarity Of Applicable Codes, Regulations, Construction Market & Labor Conditions, Geotechnical, Seismic, Weather, Environmental, Or Other Unique Considerations Found In Charleston, Sc And The Low Country Geographical Area. if Prior Experience In Charleston, Sc Is Minimal, Describe How The Design Team Plans To Obtain Specific Knowledge Of Local Conditions Or Project Features Required For A Compliant Design. data From Other Projects And Locations Are Acceptable To Highlight Knowledge Of The Charleston, Sc Geographical Area Or Areas Of Similar Nature. adjectival Scoring: offerors That Submit Relevant Projects Outside Of The Charleston, Sc Geographical Area May Be Given A Lower Rating Than Projects Within The Charleston, Sc Geographical Area. offerors That Demonstrate No Experience In The Geographical Area Shall Be Rated Not Higher Than Satisfactory . the Extent To Which Potential Contractors Identify And Commit To The Use Of Service-disabled Veteran-owned Small Businesses, Veteran-owned Small Businesses, And Other Types Of Small Businesses As Subcontractors: basis Of Evaluation: offerors Shall Be Evaluated Based On Their Utilization Plans For Service-disabled Veteran-owned Small Businesses (sdvosbs), Veteran-owned Small Businesses (vosbs), Or Other Types Of Small Businesses. offerors Shall Be Evaluated On The Expected Amount Of Work Versus Key Personnel To Verify The Above Signatory Statement. If Less Than 50% Of Work Is Estimated To Be Performed By The Prime Sdvosb, The Offeror May Be Given A Lower Rating. offerors Shall Submit Qualifications For Proposed Consultants Per Other Criteria In This Solicitation. selection Process: federal Acquisition Regulation (far) Part 36.6 (brooks Act) Selection Procedures Apply. The A-e Services Listed Herein Is Being Procured In Accordance With The Brooks Act (public Law 92-582) As Implemented In Federal Acquisition Regulation (far) 36.6 And Vaar 836.6. Pursuant To Far, The Firm Responding To This Requirement Must Be Permitted, By Law, To Practice The Professions Of Architecture Or Engineering And Meet All Required Qualifications For The State Of South Carolina. Firms Responding To This Announcement By Submitting A Qualifying Sf 330, Before The Closing Date And Time, Will Be Considered For Initial Selection Evaluation. Following Initial Evaluation Of The Sf330s Received Three Or More Firms That Are Considered The Most Highly Qualified To Provide The Type Of Services Required Will Be Selected For Interviews. Selected Firms Will Be Notified By Email Of Selection And Provided Further Instructions.
selection And Evaluation Of Firms Shall Be Made Based On Sf 330 Submissions And Direct Responses To The Selection Criteria Identified Herein. Failure To Address All Selection Criteria Will Result In A Decreased Rating. evaluating Past Performance And Experience May Include Information Provided By The Firm, Customer Inquiries, Government Databases, And Contracting Officer Knowledge Of Current Project Performance. Failure To Provide Requested Data, Accessible Points Of Contact Or Valid Phone Numbers Could Result In A Firm Being Removed From Consideration. firms That Design Or Prepare Specifications In Conjunction With This Contract Are Prohibited From Participating On Any Future Construction Contracts Based On Those Documents. All Projects Identified On The Sf330 Must Be Completed By The Office/branch/individual Team Member Performing The Work Under This Contract. submission Criteria/requirements: The Sf 330 Form May Be Downloaded From Http://www.gsa.gov/portal/forms/type/sf. Completed Sf 330 S Shall Include The Primary Firms, Subcontractor Firms And Any Consultants Expected To Be Used On The Project. Do Not Submit Information Incorporating By Reference. Prospective Firms Shall Address All Selection Criteria Factors Within Their Submitted Sf330 Packages. email Capacity Is Limited To Five (5) To Seven (7) Megabytes (megs).
the Following Format Shall Be Used:
cover Page With Solicitation Number, Project Title
table Of Contents
sf 330 S
copy Of Current A/e License
copy Of Current Vetbiz.gov Sdvosb Certification
uei Number
cage Code tax Id Number
the E Mail Address And Phone Number Of The Primary Point Of Contact. all Sf330 Submittals And Questions Must Be Sent Electronically To The Attention Of Jennifer Smith, Contract Specialist At Jennifer.smith19c497@va.gov. Please Provide Pre-solicitation Number, Project Number, Project Title, And Firm Name In Subject Line Of Email. When Submitting Sf330s, If More Than One Email Is Sent, Please Number Emails In Subjects As 1 Of N . Submittals Received After The Date And Time Identified On Page One (1) Will Not Be Considered. Firms Not Providing The Required Information May Be Negatively Evaluated. Facsimile Submittals Will Not Be Accepted. All Information Must Be Included In The Sf330. the Sf-330 Including Title Page, Table Of Contents, And Any Other Relevant Information Shall Be In A Common Font Size 12 Font, Single Spaced. The Package Shall Be Submitted As A Single Application-generated (not Scanned), Searchable Pdf Document. A Page Is Defined As Each Face Of An 8.5 X 11-inch Sheet Of Paper Containing Information. it Is The Offeror S Responsibility To Check The Sam.gov Contracting Business Opportunities Website At: Www.sam.gov For Any Revisions To This Announcement Prior To Submission Of Sf330s.
attachments: see Attached Document: Ae Past Performance Questionnaire And Cover Letter.
City of Seč Tender
Others
Czech Republic
Closing Soon13 Jan 2025
Tender AmountCZK 25 Million (USD 1 Million)
Details: The subject of the Public Contract is the Reconstruction and Construction Modification of the Sdh Seč Armory, Including Connections, Electrical Shifts, Pits and Paved Areas. Construction Modifications of the Existing Single-Storied Building with No Basement No. 112 On the plot of St. P. 672 In the Cadastral Territory Sec. The shape solution of the new building is based on the existing condition - there will be demolition of structures above the plane of the ceiling structure of the lower part, the construction of extensions from the east side with a floor plan of 8.20 X 12.0 MA Superstructures above the existing part and extensions with a floor plan of 21.3 X 8.2 M, The superstructure will be covered with a gable roof with a slope of 40° And Made Extensions To The Higher Part Of The Building On The North Side With A Floor Plan Of 3.20 X 4.90 M, Covered With A Countertop Roof. In connection with the construction modifications, demolition work will be carried out, such as the removal of the asphalt coating in the place of the superstructure, including the composition of the roof, demolition of the floors, the demolition of new openings, the removal of existing windows, some installations, the plating of attics, and also the addition and walling will be carried out. As a whole, the building will be insulated with Eps insulation.
Landkreis Havelland Der Landrat Tender
Others
Germany
Closing Soon14 Jan 2025
Tender AmountRefer Documents
Details: The Havelland district is planning to build an extension at the site of the cooperation school in Friesack. The construction work is to take place during ongoing school operations. The extension will have 3 floors. In preparation for this work, the building site must be cleared. The work advertised here is part of the overall construction work. There will be 7 contract packages for this construction work. In these award packages, the following services are awarded according to the 80/20 rule within the framework of national procedures: Vp 0 - Clearance of construction site HLS (heating, plumbing) - Clearance of construction site ELT (electrical) - Clearance of construction site other (dismantling and relocation) - Felling and clearing work - Infiltration work Vp 1 - Elevator - Construction power system - Lightning protection and earthing Vp 3 - Interior plastering - Screed work - PV system - Kitchen technology systems Vp 4 - Painting work Vp 5 - Tiling work - Floor covering work - Carpentry work Vp 6 - Building cleaning - Locking system Vp 7 - Extended shell of existing elevator shaft - Existing elevator shaft shell - Existing extension (extension of elevator shaft + relocation of student cafe)
STATE, DEPARTMENT OF USA Tender
Others...+2Electrical and Electronics, Solar Installation and Products
United States
Closing Date21 Jan 2025
Tender AmountRefer Documents
Details: U.s. Embassy Malabo date: December 20, 2024 request For Quotation # 19ek2025q0002 replacement Of On-compound Residential Solar Water Heaters the U.s. Embassy In Malabo, Equatorial Guinea Invites Vendors To Submit A Quotation For The Replacement Of On-compound Residential Solar Water Heaters. instructions To Quoters: in Order For Your Quotation To Be Considered, Each Offer Must Include The Following: completed Pricing Table – Section I - A. completed Quoter’s Info – Section Ii. completed Technical Requirements, To Include The Following Information Demonstrating The Quoter’s Ability To Perform: name Of A Project Manager (or Another Liaison To The Embassy) Who Understands Written And Spoken English. evidence That The Quoter Operates Established Business With A Permanent Address And Telephone Listing. evidence That The Quoter Has The Necessary Personnel, Equipment, And Financial Resources Available To Perform The Work. a Proof Showing That Contractor Has Already Started The Sam Registration Process. Sam Registration “system For Award Management” Is Required For Contracts Exceeding Us$30,000.00. See Exhibit A And The Following Link For Further Instructions: Https://www.fsd.gov/sys_attachment.do?sys_id=9a12412bdb7bbd90a8cb4a391396194f contractor’s Certification Regarding The National Defense Authorization Act (ndaa) Clauses (52.204-24, 52-204-25 And 52-204-26). See Certification Instructions In Exhibit B. your Quotation By Email To Malabop@state.gov No Later Than Close Of Business On Monday, Jan 6, 2025. No Quotation Will Be Accepted After This Time. you Are Encouraged To Make Your Quotation Competitive. The Rfq Does Not Commit The American Embassy To Make Any Award. The Embassy May Cancel This Rfq Or Any Part Of It. The Embassy May Award Multi Contracts Against This Requirement And It Reserves The Right To Reject Proposals/quotations That Are Unreasonably Low Or High In Price. direct Any Questions Regarding This Rfq By Email To Malabop@state.gov thank You. section I pricing Table no. description total Cost (usd) 1 replacement Of On-compound Residential Solar Water Heaters grand Total: b. Statement Of Work introduction overview & Description: The U.s. Embassy Malabo Requires The Replacement Of On-compound Residential Solar Water Heaters. The Solar Water Heaters Were Originally Installed During Initial Construction And Are At The End Of Their Useful Life. Many Have External Leaks And Are Isolated From The System. location: The Facility, U.s. Embassy Is Located In The Capital Of Equatorial Guinea, Malabo. All Onsite Inspections Shall Be Requested Through The U. S. Embassy’s Facility Manager (fm) Or Contracting Officer Representative (cor). objective: The Objective Of Solar Water Heater Replacement Is To Restore Efficiency To The Water Heating System And Reduce The Burden On Electrical Water Heaters, Effectively Extending Their Life. communication: The Fac Team Maintain Contact With The Project Lead: Michael Macsay, Facility Manager (fm), U.s. Embassy Malabo, Email: Macsaymd@state.gov, Mobile: +240-555-000-306. project Phases receipt And Inspection: Once Solar Water Heaters Are Received, They Will Be inspected By Facilities (fac) Personnel For Damage From Shipping. removal And Installation: Old Solar Water Heaters Will Be Removed From The system And Lowered To The Ground For Disposal. Replacement Water Heaters Will Be Raised To The Roof And Installed Per Manufacturer’s Instructions. 2.2.1 Note: A Crane And Rigging Will Be Required To Remove And Install Solar Water Heaters. commissioning: Upon Complete Installation, Solar Water Heaters Will Be Tested and Commissioned Within The Guidelines Set By The Manufacturer. general Requirements work Shall Be Performed In Accordance With Overseas Building Operations (obo) Safety, Health, And Environmental Management (shem) Standards. Proper Lifting And Rigging Practices Shall Be Followed During Installation And Removal The Solar Water Heaters. proper Ppe Shall Be Worn At All Times During The Removal/installation Process. work Shall Be Performed In Accordance With The Manufacturer’s Guidelines To Ensure Warranty Is Not Voided. any Damage To Grass And/or Vegetation During Removal And Installation Of Solar Water Heaters Shall Be The Responsibility Of The Fac Team To Replace. Precautions Shall Be Taken To Ensure Damage To Post’s Grass And Vegetation Is Minimized. responsibilities Of The Fac Team project Safety Plan (psp): Fm/posho And Aposho Will Develop A Project Safety Plan Using Us Army Corp Of Engineers (usace) Em385-1-1. The Plan Will Be Communicated To The Fac Staff Performing The Work. fac Staff Shall Adhere To The Project Safety Plan Throughout The Duration Of The Project. Safety Violations And Injuries Shall Be Reported Immediately To The Posho/aposho. quality Management Plan (qmp): Fm Shall Establish A Quality Management Plan To Include Inspection To Adherence With Installation Guide. Regular Inspections Between Coatings Will Be Conducted With The Designated Supervisor Of The Crew. The Crew Shall Repair Any Inconsistencies Found Within The Coatings As Defined By The Qmp. pre-project Requirements tooling & Materials: All Tooling And Materials Shall Be Inventoried Prior To The Start Of The Project To Ensure Efficiency And The Success Of The Project. All Tooling Will Be Approved By The Fm And Designated Project Supervisor Prior To Ordering. storage: Storage Shall Be Maintained In Accordance With The Storage Instructions From The Manufacturer. Proper Storage Of Resurfacing Materials Is Essential, And A Space Shall Be Identified Prior To The Project Start. all Workers Shall Review The Qmp To Understand The Standards To Be Met In The Application Of The Tennis Court Resurfacing. Any Deviation From The Installation Guide And Manufacturers Standards, May Cause The Resurfacing Materials To Degrade Or Fail Earlier Than Expected. all Workers Shall Review The Psp Set By The Fm/posho To Ensure Standards Set Forth Can And Will Be Adhered To. project Requirements all Workers Shall Adhere To The Psp Set Forth By The Fm/posho. all Workers Shall Adhere To The Qmp And Request Inspections Or Understand That Surprise Inspections Will Be Conducted To Ensure Quality Of Work. supervisor And Workers Will Adhere To The Manufacturer’s Installation Guide. technical Specifications: Refer To Appendix A For Technical Specifications Of The Solar Water Heater Requirements. reference Material work Shall Be Performed In Accordance With The Following References: manufacturer’s Installation Guide. usace 385-1-1. post Quality Management Plan (qmp) appendix A technical Specifications component specification collector Housing uv Protected cover antireflex Glass (double Coated) absorber/tank Capacity 40 Gal (150 Liter) absorber/tank Construction steel section Ii contractor’s Information & Signatures: contractor’s Name company Name address uei # ncage # office Tel # fax # mobile # email name Of Person Authorized To Sign: ___________________________________________________________ signature Of Person Authorized: ______________________________________________________________ the Penalty For Making False Statements Is Prescribed In The U.s. Criminal Code, 18 U.s.c. 1001 exhibit A sam.gov Registration the Federal Acquisition Regulation (far) - Clause # 52.204-7 - Requires All Contractors To Be Registered In The System For Award Management “sam” Database. Registration In Sam Is Mandatory Prior To Signing Any Contract That Exceeds $30,000. As We Would Like To Continue Working With You In The Near Future, We Suggest That You Start The Registration Process Asap As This Requirement Is Time Consuming. the Registration Process Starts With Obtaining A Uei Number And A Ncage Code. You Should Be Prepared To Provide The Following Information: (i) Company Legal Business. (ii) Trade Style, Doing Business, Or Other Name By Which Your Entity Is Commonly Recognized. (iii) Company Physical Street Address, City, State, And Zip Code. (iv) Company Mailing Address, City, State And Zip Code (if Separate From Physical). (v) Company Telephone Number. (vi) Date The Company Was Started. (vii) Number Of Employees At Your Location. (viii) Chief Executive Officer/key Manager. (ix) Line Of Business (industry). (x) Company Headquarters Name And Address (reporting Relationship Within Your Entity). if A Contractor Does Not Become Registered In The Sam Database In The Time Prescribed By The Contracting Officer, The Contracting Officer Will Proceed To Award To The Next Otherwise Successful Registered Contractor. if You Have Any Questions During The Registration Process, You Will Need To Contact The Customer Service For Sam By Registering Or Contacting The Following Website: federal Service Desk url: Www.fsd.gov hours: 8am - 8pm (eastern Time) us Calls: 866-606-8220 international Calls: 334-206-7828 dsn: 866-606-8220 exhibit B ndaa Certification the Us Embassy Must Comply With Section 889(a)(1)(b) Of The Fy2019 National Defense Authorization Act And Is Prohibited From Entering Into A Contract, Or Extending Or Renewing A Contract With An Entity That Uses Any Equipment, System, Or Service That Uses Covered Telecommunications Equipment Or Services As A Substantial Or Essential Component Of Any System, Or As Critical Technology As Part Of Any System, Unless A Waiver Is Granted. as Defined In Statute, Covered Telecommunications Equipment Or Services Means The Following: Telecommunications Equipment Produced By Huawei, Zte, Hikvision, Dahua, And Hytera, Or Their Subsidiaries Or Affiliates. contractor’s Certification: contractor’s Certification In Response To The National Defence Authorization Act (ndaa) Clauses (52.204-24, 52-204-25 And 52-204-26) – The Prohibition On Contracting For Certain Telecommunications And Video Surveillance Services Or Equipment: by Affixing Your Authorized Signature In Section Ii And Submitting This Certification, The Undersigned Certifies That Neither It, It’s Principals Nor Affiliates, Will Be Supporting The Us Embassy Using The Proscribed Equipment Or Services. far Clauses Incorporated In Full Text: 52.204-24 Representation Regarding Certain Telecommunications And Video Surveillance Services Or Equipment (aug 2020) the Offeror Shall Not Complete The Representation At Paragraph (d)(1) Of This Provision If The Offeror Has Represented That It “does Not Provide Covered Telecommunications Equipment Or Services As A Part Of Its Offered Products Or Services To The Government In The Performance Of Any Contract, Subcontract, Or Other Contractual Instrument” In The Provision At 52.204-26, Covered Telecommunications Equipment Or Services—representation, Or In Paragraph (v) Of The Provision At 52.212-3, Offeror Representations And Certifications-commercial Items. (a) Definitions. As Used In This Provision- backhaul, Covered Telecommunications Equipment Or Services, Critical Technology, Interconnection Arrangements, Reasonable Inquiry, Roaming, And Substantial Or Essential component Have The Meanings Provided In The Clause 52.204-25, Prohibition On Contracting For Certain Telecommunications And Video Surveillance Services Or Equipment. (b) Prohibition. (1) Section 889(a)(1)(a) Of The John S. Mccain National Defense Authorization Act For Fiscal Year 2019 (pub. L. 115-232) Prohibits The Head Of An Executive Agency On Or After August 13, 2019, From Procuring Or Obtaining, Or Extending Or Renewing A Contract To Procure Or Obtain, Any Equipment, System, Or Service That Uses Covered Telecommunications Equipment Or Services As A Substantial Or Essential Component Of Any System, Or As Critical Technology As Part Of Any System. Nothing In The Prohibition Shall Be Construed To— (i) Prohibit The Head Of An Executive Agency From Procuring With An Entity To Provide A Service That Connects To The Facilities Of A Third-party, Such As Backhaul, Roaming, Or Interconnection Arrangements; Or (ii) Cover Telecommunications Equipment That Cannot Route Or Redirect User Data Traffic Or Cannot Permit Visibility Into Any User Data Or Packets That Such Equipment Transmits Or Otherwise Handles. (2) Section 889(a)(1)(b) Of The John S. Mccain National Defense Authorization Act For Fiscal Year 2019 (pub. L. 115-232) Prohibits The Head Of An Executive Agency On Or After August 13, 2020, From Entering Into A Contract Or Extending Or Renewing A Contract With An Entity That Uses Any Equipment, System, Or Service That Uses Covered Telecommunications Equipment Or Services As A Substantial Or Essential Component Of Any System, Or As Critical Technology As Part Of Any System. This Prohibition Applies To The Use Of Covered Telecommunications Equipment Or Services, Regardless Of Whether That Use Is In Performance Of Work Under A Federal Contract. Nothing In The Prohibition Shall Be Construed To— (i) Prohibit The Head Of An Executive Agency From Procuring With An Entity To Provide A Service That Connects To The Facilities Of A Third-party, Such As Backhaul, Roaming, Or Interconnection Arrangements; Or (ii) Cover Telecommunications Equipment That Cannot Route Or Redirect User Data Traffic Or Cannot Permit Visibility Into Any User Data Or Packets That Such Equipment Transmits Or Otherwise Handles. (c) Procedures. The Offeror Shall Review The List Of Excluded Parties In The System For Award Management (sam) (https://www.sam.gov) For Entities Excluded From Receiving Federal Awards For “covered Telecommunications Equipment Or Services.” (d) Representations. The Offeror Represents That— (1) It [] Will, [] Will Not Provide Covered Telecommunications Equipment Or Services To The Government In The Performance Of Any Contract, Subcontract Or Other Contractual Instrument Resulting From This Solicitation. The Offeror Shall Provide The Additional Disclosure Information Required At Paragraph (e)(1) Of This Section If The Offeror Responds “will” In Paragraph (d)(1) Of This Section; And (2) After Conducting A Reasonable Inquiry, For Purposes Of This Representation, The Offeror Represents That— it [] Does, [] Does Not Use Covered Telecommunications Equipment Or Services, Or Use Any Equipment, System, Or Service That Uses Covered Telecommunications Equipment Or Services. The Offeror Shall Provide The Additional Disclosure Information Required At Paragraph (e)(2) Of This Section If The Offeror Responds “does” In Paragraph (d)(2) Of This Section. (e) Disclosures. (1) Disclosure For The Representation In Paragraph (d)(1) Of This Provision. If The Offeror Has Responded “will” In The Representation In Paragraph (d)(1) Of This Provision, The Offeror Shall Provide The Following Information As Part Of The Offer: (i) For Covered Equipment— (a) The Entity That Produced The Covered Telecommunications Equipment (include Entity Name, Unique Entity Identifier, Cage Code, And Whether The Entity Was The Original Equipment Manufacturer (oem) Or A Distributor, If Known); (b) A Description Of All Covered Telecommunications Equipment Offered (include Brand; Model Number, Such As Oem Number, Manufacturer Part Number, Or Wholesaler Number; And Item Description, As Applicable); And (c) Explanation Of The Proposed Use Of Covered Telecommunications Equipment And Any Factors Relevant To Determining If Such Use Would Be Permissible Under The Prohibition In Paragraph (b)(1) Of This Provision. (ii) For Covered Services— (a) If The Service Is Related To Item Maintenance: A Description Of All Covered Telecommunications Services Offered (include On The Item Being Maintained: Brand; Model Number, Such As Oem Number, Manufacturer Part Number, Or Wholesaler Number; And Item Description, As Applicable); Or (b) If Not Associated With Maintenance, The Product Service Code (psc) Of The Service Being Provided; And Explanation Of The Proposed Use Of Covered Telecommunications Services And Any Factors Relevant To Determining If Such Use Would Be Permissible Under The Prohibition In Paragraph (b)(1) Of This Provision. (2) Disclosure For The Representation In Paragraph (d)(2) Of This Provision. If The Offeror Has Responded “does” In The Representation In Paragraph (d)(2) Of This Provision, The Offeror Shall Provide The Following Information As Part Of The Offer: (i) For Covered Equipment— (a) The Entity That Produced The Covered Telecommunications Equipment (include Entity Name, Unique Entity Identifier, Cage Code, And Whether The Entity Was The Oem Or A Distributor, If Known); (b) A Description Of All Covered Telecommunications Equipment Offered (include Brand; Model Number, Such As Oem Number, Manufacturer Part Number, Or Wholesaler Number; And Item Description, As Applicable); And (c) Explanation Of The Proposed Use Of Covered Telecommunications Equipment And Any Factors Relevant To Determining If Such Use Would Be Permissible Under The Prohibition In Paragraph (b)(2) Of This Provision. (ii) For Covered Services— (a) If The Service Is Related To Item Maintenance: A Description Of All Covered Telecommunications Services Offered (include On The Item Being Maintained: Brand; Model Number, Such As Oem Number, Manufacturer Part Number, Or Wholesaler Number; And Item Description, As Applicable); Or (b) If Not Associated With Maintenance, The Psc Of The Service Being Provided; And Explanation Of The Proposed Use Of Covered Telecommunications Services And Any Factors Relevant To Determining If Such Use Would Be Permissible Under The Prohibition In Paragraph (b)(2) Of This Provision. (end Of Provision) 52.204-25 Prohibition On Contracting For Certain Telecommunications And Video Surveillance Services Or Equipment (aug 2020) definitions. As Used In This Clause— backhaul Means Intermediate Links Between The Core Network, Or Backbone Network, And The Small Subnetworks At The Edge Of The Network (e.g., Connecting Cell Phones/towers To The Core Telephone Network). Backhaul Can Be Wireless (e.g., Microwave) Or Wired (e.g., Fiber Optic, Coaxial Cable, Ethernet). covered Foreign Country Means The People's Republic Of China. covered Telecommunications Equipment Or Services Means— (1) Telecommunications Equipment Produced By Huawei Technologies Company Or Zte Corporation (or Any Subsidiary Or Affiliate Of Such Entities); (2) For The Purpose Of Public Safety, Security Of Government Facilities, Physical Security Surveillance Of Critical Infrastructure, And Other National Security Purposes, Video Surveillance And Telecommunications Equipment Produced By Hytera Communications Corporation, Hangzhou Hikvision Digital Technology Company, Or Dahua Technology Company (or Any Subsidiary Or Affiliate Of Such Entities); (3) Telecommunications Or Video Surveillance Services Provided By Such Entities Or Using Such Equipment; Or (4) Telecommunications Or Video Surveillance Equipment Or Services Produced Or Provided By An Entity That The Secretary Of Defense, In Consultation With The Director Of National Intelligence Or The Director Of The Federal Bureau Of Investigation, Reasonably Believes To Be An Entity Owned Or Controlled By, Or Otherwise Connected To, The Government Of A Covered Foreign Country. critical Technology Means— (1) Defense Articles Or Defense Services Included On The United States Munitions List Set Forth In The International Traffic In Arms Regulations Under Subchapter M Of Chapter I Of Title 22, Code Of Federal Regulations; (2) Items Included On The Commerce Control List Set Forth In Supplement No. 1 To Part 774 Of The Export Administration Regulations Under Subchapter C Of Chapter Vii Of Title 15, Code Of Federal Regulations, And Controlled— (i) Pursuant To Multilateral Regimes, Including For Reasons Relating To National Security, Chemical And Biological Weapons Proliferation, Nuclear Nonproliferation, Or Missile Technology; Or (ii) For Reasons Relating To Regional Stability Or Surreptitious Listening; (3) Specially Designed And Prepared Nuclear Equipment, Parts And Components, Materials, Software, And Technology Covered By Part 810 Of Title 10, Code Of Federal Regulations (relating To Assistance To Foreign Atomic Energy Activities); (4) Nuclear Facilities, Equipment, And Material Covered By Part 110 Of Title 10, Code Of Federal Regulations (relating To Export And Import Of Nuclear Equipment And Material); (5) Select Agents And Toxins Covered By Part 331 Of Title 7, Code Of Federal Regulations, Part 121 Of Title 9 Of Such Code, Or Part 73 Of Title 42 Of Such Code; Or (6) Emerging And Foundational Technologies Controlled Pursuant To Section 1758 Of The Export Control Reform Act Of 2018 (50 U.s.c. 4817). interconnection Arrangements Means Arrangements Governing The Physical Connection Of Two Or More Networks To Allow The Use Of Another's Network To Hand Off Traffic Where It Is Ultimately Delivered (e.g., Connection Of A Customer Of Telephone Provider A To A Customer Of Telephone Company B) Or Sharing Data And Other Information Resources. reasonable Inquiry Means An Inquiry Designed To Uncover Any Information In The Entity's Possession About The Identity Of The Producer Or Provider Of Covered Telecommunications Equipment Or Services Used By The Entity That Excludes The Need To Include An Internal Or Third-party Audit. roaming Means Cellular Communications Services (e.g., Voice, Video, Data) Received From A Visited Network When Unable To Connect To The Facilities Of The Home Network Either Because Signal Coverage Is Too Weak Or Because Traffic Is Too High. substantial Or Essential Component Means Any Component Necessary For The Proper Function Or Performance Of A Piece Of Equipment, System, Or Service. (b) Prohibition. (1) Section 889(a)(1)(a) Of The John S. Mccain National Defense Authorization Act For Fiscal Year 2019 (pub. L. 115-232) Prohibits The Head Of An Executive Agency On Or After August 13, 2019, From Procuring Or Obtaining, Or Extending Or Renewing A Contract To Procure Or Obtain, Any Equipment, System, Or Service That Uses Covered Telecommunications Equipment Or Services As A Substantial Or Essential Component Of Any System, Or As Critical Technology As Part Of Any System. The Contractor Is Prohibited From Providing To The Government Any Equipment, System, Or Service That Uses Covered Telecommunications Equipment Or Services As A Substantial Or Essential Component Of Any System, Or As Critical Technology As Part Of Any System, Unless An Exception At Paragraph (c) Of This Clause Applies Or The Covered Telecommunication Equipment Or Services Are Covered By A Waiver Described In Far 4.2104. (2) Section 889(a)(1)(b) Of The John S. Mccain National Defense Authorization Act For Fiscal Year 2019 (pub. L. 115-232) Prohibits The Head Of An Executive Agency On Or After August 13, 2020, From Entering Into A Contract, Or Extending Or Renewing A Contract, With An Entity That Uses Any Equipment, System, Or Service That Uses Covered Telecommunications Equipment Or Services As A Substantial Or Essential Component Of Any System, Or As Critical Technology As Part Of Any System, Unless An Exception At Paragraph (c) Of This Clause Applies Or The Covered Telecommunication Equipment Or Services Are Covered By A Waiver Described In Far 4.2104. This Prohibition Applies To The Use Of Covered Telecommunications Equipment Or Services, Regardless Of Whether That Use Is In Performance Of Work Under A Federal Contract. (c) Exceptions. This Clause Does Not Prohibit Contractors From Providing— (1) A Service That Connects To The Facilities Of A Third-party, Such As Backhaul, Roaming, Or Interconnection Arrangements; Or (2) Telecommunications Equipment That Cannot Route Or Redirect User Data Traffic Or Permit Visibility Into Any User Data Or Packets That Such Equipment Transmits Or Otherwise Handles. (d) Reporting Requirement. (1) In The Event The Contractor Identifies Covered Telecommunications Equipment Or Services Used As A Substantial Or Essential Component Of Any System, Or As Critical Technology As Part Of Any System, During Contract Performance, Or The Contractor Is Notified Of Such By A Subcontractor At Any Tier Or By Any Other Source, The Contractor Shall Report The Information In Paragraph (d)(2) Of This Clause To The Contracting Officer, Unless Elsewhere In This Contract Are Established Procedures For Reporting The Information; In The Case Of The Department Of Defense, The Contractor Shall Report To The Website At Https://dibnet.dod.mil. For Indefinite Delivery Contracts, The Contractor Shall Report To The Contracting Officer For The Indefinite Delivery Contract And The Contracting Officer(s) For Any Affected Order Or, In The Case Of The Department Of Defense, Identify Both The Indefinite Delivery Contract And Any Affected Orders In The Report Provided At Https://dibnet.dod.mil. (2) The Contractor Shall Report The Following Information Pursuant To Paragraph (d)(1) Of This Clause: (i) Within One Business Day From The Date Of Such Identification Or Notification: The Contract Number; The Order Number(s), If Applicable; Supplier Name; Supplier Unique Entity Identifier (if Known); Supplier Commercial And Government Entity (cage) Code (if Known); Brand; Model Number (original Equipment Manufacturer Number, Manufacturer Part Number, Or Wholesaler Number); Item Description; And Any Readily Available Information About Mitigation Actions Undertaken Or Recommended. (ii) Within 10 Business Days Of Submitting The Information In Paragraph (d)(2)(i) Of This Clause: Any Further Available Information About Mitigation Actions Undertaken Or Recommended. In Addition, The Contractor Shall Describe The Efforts It Undertook To Prevent Use Or Submission Of Covered Telecommunications Equipment Or Services, And Any Additional Efforts That Will Be Incorporated To Prevent Future Use Or Submission Of Covered Telecommunications Equipment Or Services. (e) Subcontracts. The Contractor Shall Insert The Substance Of This Clause, Including This Paragraph (e), In All Subcontracts And Other Contractual Instruments, Including Subcontracts For The Acquisition Of Commercial Items. (end Of Clause) 52.204-26 Covered Telecommunications Equipment Or Services-representation (dec 2019) (a) Definitions. As Used In This Provision, “covered Telecommunications Equipment Or Services” Has The Meaning Provided In The Clause 52.204-25, Prohibition On Contracting For Certain Telecommunications And Video Surveillance Services Or Equipment. (b) Procedures. The Offeror Shall Review The List Of Excluded Parties In The System For Award Management (sam) (https://www.sam.gov) For Entities Excluded From Receiving Federal Awards For “covered Telecommunications Equipment Or Services”. (c) Representation. The Offeror Represents That It □ Does, □ Does Not Provide Covered Telecommunications Equipment Or Services As A Part Of Its Offered Products Or Services To The Government In The Performance Of Any Contract, Subcontract, Or Other Contractual Instrument. (end Of Provision)
Slots Og Kulturstyrelsen - DENMARK Tender
Others
Denmark
Closing Date26 Jan 2025
Tender AmountRefer Documents
Details: Title: Service And Cleaning Of Kongens Have And Frederiksberg Garden Type: Eu Tender Expected Contract Period: 5 Years With The Possibility Of Extension Of 3 Times 1 Year Expected Publication Of Tender: 3rd Quarter 2024 Contact: Center For Group It And Tenders, Kui@ Slks.dk Title: Garden Management Of Koldinghus, Aalborghus, Frederiksberg, Sorgenfri, Marienborg And Frilandsmuseet Type: Eu-tender Expected Contract Period: 5 Years With The Possibility Of Extension Of 3 Times 1 Year Expected Publication Of Tender: 2nd Quarter 2024 Contact: Center For Koncern It Og Udbud, Kui@slks.dk Title: Forest Management Of Fredensborg And Frederiksborg Type: Eu-tender Expected Contract Period: 5 Years With The Possibility Of Extension Of 3 Times 1 Year Expected Publication Of Tender: 2nd Quarter 2024 Contact: Center For Koncern It Og Udbud, Kui@slks.dk Title: Purchase Of Electrical Charging Points And Parking Control Type: Advertising Expected Contract Period: 5 Years Expected Publication: 2nd Quarter 2024 Contact: Center For Group It Og Udbud, Kui@slks.dk Title: Development , Maintenance And Support Of It Support In The Cultural Heritage Area Type: Eu Tender Expected Publication Of Tender: 2nd Quarter 2024 Contact: Center For Group It And Tenders, Kui@slks.dk
Kofola ČeskoSlovensko as Tender
Others
Czech Republic
Closing Date17 Jan 2025
Tender AmountRefer Documents
Details: The subject of the Public Contract is the realization of the Building So 101 - Building Modifications and Extension of the Existing Building Nkp New Bathroom. The New Bathrooms Building Will Mainly Have An Administrative Function Complemented By An Exhibition Circuit And A Publicly Accessible Exhibition Space. The exterior brickwork will be restored and new windows will be made according to the original layout. Luxfer fillings will be preserved, some windows on the ground floor will be raised to the height of the demolished parapets, thereby creating entrances and landings. The original 6 X 6 M skeleton will be rehabilitated (vertical and horizontal elements will be strengthened). Free Spaces of Open Offices Will Be Created, Two-Storied Space of Chain Wardrobes Will Be Divided Horizontally by an Inserted Wall, While the Chain Wardrobe System Will Remain. The Original Stairs In The Vertical Towers Will Be Removed And Replaced With New Stairs. As part of the Building Modifications, New Wall Structures, New Surface Modifications, and New Furnishings will be installed, incl. Connection to new water and sewage distribution systems, new electrical installation, air conditioning and air conditioning will also be carried out. The source of heat for heating and air conditioning needs is the hot water transfer station, located in 1. Pp. The source of cooling is a compressor cold water generator for summer operation and a direct cooling device for winter operation. See Tender Documentation for details.
DEPT OF THE AIR FORCE USA Tender
Aerospace and Defence
United States
Closing Date30 Jan 2025
Tender AmountRefer Documents
Details: Notice: this Sources Sought Synopsis/request For Information (sss/rfi) Is Issued For Informational Purposes And Market Research Only. This Is Not A Request For A Quote, Request For Proposal, Or An Invitation To Bid, Nor Is This To Be Construed As A Commitment By The Government To Issue A Solicitation Or Ultimately Award A Contract. This Request Neither Constitutes A Solicitation For Proposals Nor The Authority To Enter Negotiations To Award A Contract. Additionally, This Sss Does Not Restrict The Government To A Particular Acquisition Approach. The Government Will Not Reimburse Any Company Or Individual For Any Expenses Associated With Preparing/submitting Information In Response To This Posting Or Any Follow-up Information Requests. Responders Are Advised That The Government Will Not Pay For Any Information Or Administrative Costs Incurred In Response To This Sss. All Costs Associated With Responding To This Sss Will Be Solely At The Responding Party’s Expense. No Funds Have Been Authorized, Appropriated, Or Received For This Effort. The Information Provided May Be Used By The Government In Developing Its Acquisition Strategy, Statement Of Work/statement Of Objectives, And Performance Specifications. Interested Parties Are Responsible For Adequately Marking Proprietary Or Competition Sensitive Information Contained Within Their Response As Instructed Later In This Sss/rfi. The Government Shall Not Be Liable For, Or Suffer Any Consequential Damages, For Any Proprietary Information Not Properly Identified. Please Be Advised That All Submissions Become Government Property And Will Not Be Returned. overview: the Air Force Life Cycle Management Center (aflcmc), Human Systems Division (hsd), Combat Ready Airman (cra) Branch, Wright-patterson Afb, Oh Is Conducting Market Research To Identify Possible Vendors And/or Manufacturers That Can Provide Aviator Helmets That Are Compatible With Fixed Wing Ejection And Non- Ejection Systems On Multiple Usaf Aircraft Weapon Systems. background Information: usaf Aircrew Require The Ability To Easily And Rapidly Transition Between Symbology Displays, Cueing, And Night Vision Or Use These Devices Simultaneously For Optimum Capability. Installing These Advanced Avionics On The Current 20+ Year Old Helmet Degrades The System's Operational Performance. If This Helmet Is Not Modified, Aircrew Will Continue To Have To Overcome Jitter, Loss Of Night Vision Image And Display Symbology, Neck Strain, And Increased Potential For Injury During Ejection. In Addition, Proprietary Helmets Designed To Optimize Specific Displays Will Be Introduced Into The Inventory, Increasing Logistical Footprint. current Helmets Are Not Optimized For Use With Night Vision And Weapon Cueing/display Systems Required To Operate Modern Aircraft. Currently, Employing These Devices Require Extensive Modifications To Current Helmets That Were Not Designed To Accommodate Them. This Results In Poor Weight Distribution And Stability Which Contributes To Mission Degradation, Aircrew Fatigue, Neck Strain, And An Increased Potential For Injury. In Addition, Current Helmets Do Not Provide Adequate Noise And Impact Protection. systems Requirements: please Provide Information Regarding The Following Capabilities Of Your Helmet System Regarding The Following Categories And Provide Rationale How It Is Compliant: key Performance Parameter (kpp) 1. Kpp #1: Stability the Fwh Will Provide A Stable Fixed Reference To The User’s Eye Through The Full Range Of Aircraft Operations. When Used With Helmet Mounted Equipment, There Will Be No Vignetting (loss) Of Symbology Or Imagery Or Loss Of Resolution Of Optical Systems. how Much Tension Load Can Your Helmet Withstand Over A 2.0-minute Exposure? 2. Kpp #2: Equipment Compatibility the System And Its Components Will Be Compatible With And Not Degrade Aircrew Flight Equipment And Helmet Mounted Devices. how Does Your Helmet System Integrate With Current Helmet Mounted Displays (hmds) (i.e. Joint Helmet Mounted Cueing System (jhmcs), Hybrid Optical-based Inertial Tracker (hobit), Night Vision Goggles (nvgs))? are You Compatible With Any Other Hmds, Not Specifically Called Out? what Capability Do You Have To Work With Other Companies To Understand Future Requirements/technologies For Helmet-related Systems To Include Hmds (ijhmcs, Etc.), Oxygen Masks, And Visors? is Your Helmet System Compatible With The Equipment Listed In Attachment I? 3. Kpp# 3:weight, Center Of Gravity, And Principal Moments Of Inertia the Weight, Center Of Gravity (cg), And Principal Moments Of Inertia (moi) Of The Fwh (in All Configurations) Will Decrease Neck Loads (compared To The Helmet(s) It Replaces) To The Aircrew During High-g Maneuvering, Bailout, 600 Knots Equivalent Air Speed (keas) Ejection, Parachute Opening, Ditching, And Crash-landing Scenarios. what Data Can You Provide To Support Your Helmet Reduces Weight, Cg, And Moi To Decrease Neck Loads? what Evidence Can You Provide To Show Your Helmet Decreases Neck Loads Against Mil-hdbk-516c, For Example: Multi-axial Neck Injury Criteria – Y Axis (manicy), Neck Moment Index (nmix), And Probability Of Concussion (poc)? key System Attributes (ksa) Capability 4. Impact Protection the System Will Protect The Crewmember’s Head From Impacts Associated With Basic Aircraft Maneuvers, Ejection, Bailout, Ditching, And Crash Landing Better Than The Helmet It Replaces what Data Can You Provide To Show That Your Helmet Can Withstand A 600 Keas Ejection Sequence With Limited Physical Damage That Would Cause Injury To The Aircrew Or Impair The Ability Of The Helmet To Protect The Aircrew? what Data Can You Provide To Show That No Part Of The Helmet System Will Become Foreign Object Debris In A 600 Keas Windblast? 5. Logistics fwh Variants Will Use Common Components To Reduce The Logistical Footprint Compared To Existing Systems, And Be Organically Supportable By Defense Logistics Agency. 6. Anthropometric Accommodation the Fwh Will Accommodate The Central 99% Of The Male And Central 99% Of The Female Aircrew Population (with 90% Confidence) In The Minimum Number Of Sizes, With The Remainder Being Fitted With Minor Modifications To Existing Sizes. 7. Acoustic Dose the Fwh Will Ensure Wearers Experience Acceptable Noise Levels, Technically Defined As Less Than Or Equal To 100% Acoustic Dose (1.0 Total Daily Exposure (tde) @ Mean -2 Standard Deviations (sd) Performance For Fit) For Crew Positions In 90% Of Aircraft. 8. Speech Intelligibility the Fwh Will Enable Helmeted Aircrew To Score Greater Than 80% On The Modified Rhyme Test (mrt) In The Laboratory With Talker And Listener Under Simulated Flight Noise Conditions. 9. Fit/wearability the Fwh Fit, In All Configurations, Will Be Repeatable, Accommodate Missions Of Extended Duration, And Not Cause Hot Spots/pressure Points That Degrade Performance On 95% Of Aircrews. 10. Aircraft Compatibility the Fwh Will Be Compatible With The Aircraft Without Requiring Aircraft Modifications. 11. In-flight Mission Reconfiguration the Fwh Will Accommodate Safe And Rapid In-flight Reconfiguration Of Fielded And Post-milestone B Helmet Mounted Devices Without Removing The Helmet During All Mission Profiles No Worse Than Legacy. additional Performance Attributes 12. Head Supported Weight. the Mass Properties Of The System Will Not Decrease The Ability Of The Wearer To Perform Related Tasks Over The Duration Of The Mission. what Is The Weight Of Your Helmet System As Operationally Worn For The Slick Configuration? Weight Reported Will Include Fully Assembled Base Helmet As Worn By The User, Excluding Interfacing Aircrew Flight Equipment (afe) (i.e. No Oxygen Mask, Or External Communication Cabling). Please Report The Weights For Each Size Of The Helmet System. in Addition To Head Supported Weight Of Your Helmet System (described Above), Report Mass Properties Of Your Helmet System, In All Configurations, For Day And Night Operations, Using The Template And Guidance Found In Attachment Ii. Upon Reporting According To The Template, Describe Set-up And Methods Utilized For Collecting Measurements. 13. Eye Protection the Fwh (in All Configurations) Will Shield The Eyes During All Flight And Ground Operations, From Adverse Effects Of Solar Radiation, Windblast, Airborne Debris, Bailout, Ditching, And 600 Keas Ejection. tell Us How Your Helmet System Will Provide Eye Protection In All Phases Of Ejection (initiation Of Ejection To Ground Landing), During Day And Night Operations With Respect To Slick, Jhmcs, Hobit, And Nvgs. what Data Can You Provide To Show That The Visor Of Your Slick Helmet System Remains In A Down And Locked Position During All Phases Of A 600 Keas Ejection (initiation Until Ground Landing), During Day And Night Operations? what Data Can You Provide To Show That Your Helmet System In The Jhmcs And Hobit Configuration Provides Eye Protection To The User During All Phases Of A 450 Keas Ejection (initiation Until Ground Landing), During Day And Night Operations? 14. Visor/visual Compatibility the Fwh Will Provide Aircrew The Ability To Rapidly Transition Between Two Visors Using One Gloved Hand During Flight Operations. The Visors’ Optical Distortion Qualities And Transmissivity Options Will Be Equal To Or Better Than The Visor Configurations They Replace. does Your Visor Meet The Criteria In Mil-dtl-43511d? If Any Deviations Exist, Please Note Them. 15. Field Of View/regard the Fwh Will Provide A Field Of View And Field Of Regard Equal To The Helmet Being Replaced. 16. Penetration Protection the System Will Protect The Crewmember’s Head From Penetrations Associated With Basic Aircraft Maneuvers, Ejection, Bailout, Ditching, And Crash Landing To A Level Equivalent To The Helmet It Replaces. what Data Can You Supply From Testing To Show That Your Helmet System Supplies Protection Against Impact And Penetration? 17. Retention the Fwh And Visor Will Be Safely Retained And Remain In Its Worn Position When Exposed To A 600 Keas Ejection tell Us How Your Helmet System Can Be Retained In All Phases Of Ejection (initiation Of Ejection To Ground Landing). 18. Bulk the Helmet Shape And Cabling Will Not Interfere With Aircrew Mobility, Ingress/egress (including Emergency Egress) Requirements, Or The Operation Of The Ejection Seats In All Aircraft. 19. Spinal Alignment the Helmet Shape Will Enable Proper Spinal Alignment During Flight When Interfacing With The Ejection Seat Head Pad. 20. Audio Compatibility the Fwh Noise Attenuation System Will Be Compatible With All Aircraft Systems And Will Not Impede Recognition Of Audible Aircraft Warning/caution Systems, Night Vision Equipment, Weapons System Employment, Or Decrease Accuracy Of Helmet-mounted Cueing Devices. 21. Aircraft Cockpit Simulator Compatibility the Fwh Will Be Compatible With All Existing Aircraft Cockpit Simulators. If New Adapters Are Required, They Must Be Provisioned For And Provided As Part Of The System. 22. Internal Communication Systems (ics) the Fwh Noise Attenuation System Will Be Compatible With All Aircraft Icss. 23. Emergency Ground Egress the Fwh Will Not Interfere With Emergency Ground Egress Procedures Or Require Any Additional Aircrew Action To Disconnect The Helmet System From The Aircraft Wiring (i.e. Disconnect Will Break Away During Aircrew Egress). 24. Fire Safety the Fwh Will Provide Flame, Drip, And Melt Protection Equal To Or Better Than Current Fielded Helmets. 25. Don And Doff aircrew Will Be Able To Don And Doff The Helmet Without Assistance. The Aircrew Will Be Able To Remove The Helmet During An Emergency With One Hand Using Either Hand. 26. Audio Performance the System Will Provide Broadband Audio Output With Minimal Distortion And Ensure Overall Sound Pressure Level And Electrical Polarity Are Matched Across Both Ears. what Data Can You Provide For Audio Performance Testing That You Have Conducted On Your Helmet System? if Available Please Provide Specifics On: Broadband Frequency Response, Distortion, Sensitivity Balance, Volume Control, And Speech Intelligibility. 27. Volume Control adjustment Of The Aircraft Ics Volume Control Will Result In A Corresponding Volume Change At The Ear. 28. Cockpit Illuminator the Fwh Will Provide A Modular, Night Vision Compatible Light Source With An On/off Switch Selectable By The Aircrew During Flight. 29. 3-d Audio the Fwh Will Be Capable Of Accepting 3-d Audio Cueing For Radio Communication And Threat/targeting Information. what Data Can You Provide To Show Your Helmet Provides 3d Spatial Audio Support? 30. External Audio fwh Will Be Capable Of Providing An External Audio Capability That Allows Dismounted Aircrew The Ability To Hear The External Environment While Wearing The Helmet. 31. Atmospheric Pressure Changes the Fwh Will Not Increase The Risk Of Aircrew Injury Throughout The Range Of Atmospheric Pressure Changes Experienced During Flight. 32. Altitude Protection the Fwh Will Allow Users To Safely Operate Aircraft At Altitudes Up To The Maximum Operational Cabin Altitude. 33. Emi/emc Compatibility the Fwh Will Not Emit Electromagnetic Energy That Exceeds The Limits Of Mil-std-461 And Ads-37a-prf As It Applies To Mission Critical Equipmentor Be Degraded By Electronic Emissions In Its Operational Environment. 28. Cockpit Illuminator the Fwh Will Provide A Modular, Night Vision Compatible Light Source With An On/off Switch Selectable By The Aircrew During Flight. 29. 3-d Audio the Fwh Will Be Capable Of Accepting 3-d Audio Cueing For Radio Communication And Threat/targeting Information. what Data Can You Provide To Show Your Helmet Provides 3d Spatial Audio Support? 30. External Audio fwh Will Be Capable Of Providing An External Audio Capability That Allows Dismounted Aircrew The Ability To Hear The External Environment While Wearing The Helmet. 31. Atmospheric Pressure Changes the Fwh Will Not Increase The Risk Of Aircrew Injury Throughout The Range Of Atmospheric Pressure Changes Experienced During Flight. 32. Altitude Protection the Fwh Will Allow Users To Safely Operate Aircraft At Altitudes Up To The Maximum Operational Cabin Altitude. 33. Emi/emc Compatibility the Fwh Will Not Emit Electromagnetic Energy That Exceeds The Limits Of Mil-std-461 And Ads-37a-prf As It Applies To Mission Critical Equipment Or Be Degraded By Electronic Emissions In Its Operational Environment. 34. Electrostatic Discharge (esd). fwh Performance Will Not Be Affected By Esd Events. 35. Communication Devices the System Will Be Compatible With Or Replace Current Communications Devices Designed For Use With Aircrew Helmets And Oxygen Masks. 36. Boom Microphones the Fwh Will Be Compatible With A Boom Microphone. 37. Habitability fwh Will Allow Aircrew The Unimpeded Ability To Eat, Hydrate, And One- Handed Valsalva. 38. Operability direct Manipulation Of The Donned Fwh By The Aircrew Under Operational Conditions, Will Require Only One Gloved (standard Nomex Flight Glove) Hand To Easily Operate Any Mechanism. 39. Positive Pressure Breathing the Fwh Will Allow For The Effective Use Of Positive Pressure Breathing For Altitude And G Systems. 40. Temperature And Moisture Control the Fwh Will Incorporate A Washable Moisture-wicking And Anti-microbial Interface That Does Not Present A Burn Hazard In Extreme Thermal Survival Environments. 41. Reliability the Minimum Acceptable Mean-time-between-critical Failure (mtbcf) Is Seven Years. 42. Maintainability mean Repair Time (mrt) Will Not Exceed 0.5 Hours, With 95 Percent Of The Tasks Not Exceeding 3.0 Hours. 43. Durability the Fwh And Its Components Will Be Shatter Proof, Non-reflective, And Have Abrasion/chip/stain/ Corrosion Resistance Equal To The Current System. 44. Materials And Helmet Shape materials And Helmet Shape Will Not Damage Aircraft Canopies, Windscreens, Other Transparencies, And Structures. 45. Survival And Rescue Compatibility the Fwh Will Not Interfere With Or Degrade The Performance Of Any Survival/rescue Equipment Or Procedures. 46. Support Equipment (se) if New Tmde, Se, Or Tools Are Required, They Must Be Provisioned For And Provided As Part Of The System. 47. Maintenance Planning maintenance, Repair, And Reconstitution Tasks Will Be Accomplished By Appropriately Qualified Organizational Level Aircrew Flight Equipment Specialist. 48. Maintenance Environment system Design Will Allow Maintenance To Be Performed In Hostile Environmental Conditions (e.g. Arctic And Mopp-4) At Operating Bases/locations Worldwide To Include Mobile, Sea-based, And Bare-base Facilities. 49. Inspections periodic Inspections And Preventive Maintenance Tasks Will Be Sufficient To Ensure System Integrity. Inspection Intervals Will Be Equal To The Helmet It Replaces. 50. Technical Data technical Orders/manuals (to/tm) For Integration/operation And Repair Will Include Illustrated Parts Breakdowns, Parts Listings, Diagrams, Theory Of Operation, Maintenance, And Troubleshooting Guides. The Technical Data Will Be Formally Verified, Validated, And Approved By The Appropriate Agencies Prior To The Delivery Of The First System. Time And Cost To Fully Incorporate Technical Data Will Be Part Of The Program Cost And Schedule. 51. Manpower manning Required For The System Should Meet Current Authorized Levels. Specifically, No Additional Logistics, Maintenance Or Aircrew Flight Equipment Authorizations Will Be Required To Support The New Helmet. 52. Human Factors Engineering human Factors Engineering Principles Specified In Mil-std-1472 Should Be Employed To The Maximum Extent Possible In Each Fwh System Solution. instructions To Potential Respondents: 1. Submit One (1) Electronic Copy To Ms. Samantha Mckee, Samantha.mckee.1@us.af.mil, No Later Than 6:00 Pm Est On 30 January 2025. Title E-mail Responses In The Subject Line Of The E-mail As Follows: “response To Next Generation Fixed Wing Helmet Rfi Rou-a044401.” 2. Respondents, Please Provide Data That Can Support These Questions As Well As Ejection Data That You Have. Respondents Shall Provide Capability Descriptions In The Same Format As The Above System Requirements Table, Attachment I – Equipment Compatibility, And Attachment Ii – Mass Properties And Should Include Technical And Descriptive Text To Provide Sufficient Detail On How The Proposed Solutions Will Benefit The Human Systems Division (hsd), As Outlined In The Systems Requirements Section Above. Submissions Shall Be Limited To No More Than 28 Pages Inclusive Of Answers To Requirement Specifications/questions Detailed In The Matrix Above; Any Necessary Product Sheets, Test Data, Graphs, And Charts Supporting Those Answers Shall Be Limited To No More Than 5 Pages As Well As A Rom (detailed Below) Of No More Than 3 Pages. Please Identify A Representative To Support Further Government Inquiries And Requests For Clarification Of The Information Provided, If Needed. Marketing Materials Are Considered An Insufficient Response To This Sources Sought Synopsis. 3. Please Provide A Rough Order Of Magnitude (rom) Cost Estimate. Rom Length Should Be No More Than 3 Pages. Provide Estimated Cost For The Following: This Section Of Your Response Should Provide Estimated Costs For Development, Non-recurring Engineering, Qualification Testing, And Future Production Costs. Specifically For Production, Include Helmet Unit Costs And Monthly Production Capacity For A Total 22,500 Production Units. The Government Is Interested In Obtaining Product Support Engineering Data Or A Technical Data Package (tdp) That Includes The Appropriate Level Of Data To Support An Organic Level Of Maintenance (that Could Include Up To Level 3 Drawings Iaw Mil-std-31000, Rev B, Sections 4.2 And 5.4.1.3). Furthermore, Please Provide An Estimate For Technical Manuals For The Helmets, Initial Provisioning Data And Any Required Updates Through Full Rate Production, And Training Costs To Include Training Evaluations And Fielding. 4. Please Provide A Program Schedule To Include Emd, Production, And Fielding Timelines. 5. Responses Shall Include The Following Information: company/institute Name: address: point Of Contact (to Include Phone Number And Email Address): cage Code: unique Entity Id: web Page Url: state Whether The Company Is Domestically Or Foreign Owned (if Foreign, Indicate The Country Of Ownership). state Whether The Company Is Interested In Being A Prime Contractor Or Subcontractor For This Requirement. state The Company’s Manufacturing Readiness Level In Support Of Helmet Production And Provide A Manufacturing Readiness Assessment. state The Business Readiness To Support Financial Capabilities To Support Government Testing And Production Of Helmets. provide Data Supporting Design Is Stable And Meets Above Listed Capabilities And Requirements Outlined In Table Above. provide Supply Chain Process And Capabilities To Support Helmet Production. lead Time Projected For Vendors To Support Manufacturing Of First Article Delivery provide An Assertion Your Helmet System Is Compliant With The Following Regulations: far 52.225-1, Buy American-supplies dfars 252.225-7012, Preference For Certain Domestic Commodities provide Data Rights Assertions, Please Use The Table Below: contractors Must Identify Any Noncommercial Data (data Is Technical Data And Computer Software) To Be Delivered Or Otherwise Provided Under The Contract To The Government With Data Rights Requirements More Restrictive That Unlimited Data Rights. provide Assertions At The Lowest Practical Segregable Level: software: Module Or Subroutine technical Data: Subsystem, Component Or Sub-component. refer To Dfars 252.227-7017 For Appropriate Language data Rights Assertions | Technical Data/computer Software To Be Furnished With Restrictions |basis Of Assertion |asserted Rights Category |person Asserting Restrictions 6. All Prospective Contractors Must Be Registered In The System For Award Management (sam) Database To Be Awarded A Dod Contract. The North American Industry Classification System (naics) Code For This Requirement, If Applicable To The Company’s Capabilities, Should Be Included In The Company’s Naics Code Listing In Sam. To Learn More About This Sam Requirement And How To Register, Please Visit The Sam Website At Https://www.sam.gov/ 7. The Naics Code For This Action Is 339113 – Helmets (except Athletic), Safety (e.g., Motorized Vehicle Crash Helmets, Space Helmets), Manufacturing With A Size Standard Of 800 Employees. Based On This Naics Code, Indicate Whether Your Company Qualifies As A: self-certified Or Third Party Certified Small Business (yes / No) self-certified Or Third Party Certified Women-owned Small Business (yes / No) self-certified Or Third Party Certified Economically Disadvantaged Women- Owned Small Business (yes/no) self-certified Or Third Party Certified Hubzone Certified (yes / No) self-certified Or Third Party Certified Veteran-owned Small Business (yes / No) self-certified Or Third Party Certified Service-disabled-veteran-owned Small Business (yes / No) self-certified Or Third Party Certified 8(a) (yes / No) self-certified Or Third Party Certified Sba certification Date: ____________ sba Graduation Date: ______________ communication And Additional Considerations: in Accordance With Far 15.201(e), Responses To This Notice Are Not Offers And Cannot Be Accepted By The U.s. Government To Form A Binding Contract. the Government Will Not Award A Contract On The Basis Of This Rfi. A Determination Not To Compete This Action Based On Responses Received Is Solely Within The Government’s Discretion. the Acquisition Strategy Is Still Being Determined. Market Research Results Will Assist The Air Force In Determining Whether This Requirement Will Be A Full And Open Competition, A Small Business Set Aside, A Sole Source Acquisition, Or Utilization Of Dla Contract. not Responding To This Sss Does Not Preclude Participation In Any Future Rfp, If Any Is Issued. the Government May Contact Respondents To Obtain Additional Information Or Clarification In Order To Fully Understand A Response. This May Include Discussions, Site Visits, Demonstrations, Etc. To Further The Government’s Understanding Of A Proposed Effort, As Well As The Respondent’s Understanding Of The Government’s Requirements. responses To Questions From Interested Parties Will Be Promptly Answered And Posted On Sam.gov Unless Some Release Of Proprietary Information Is Involved Or The Answer Addresses A Question Peculiar To A Company Or That Company’s Response. Post Submittal, One-on-one Information Sessions With Respondents Are Not Contemplated; However, They May Be Offered To Respondents To Clarify The Government’s Understanding Of Their Submittal, The Capability Ramifications, Or To Discuss Their Business Approach. Information Feedback Sessions May Be Offered To Respondents After The Sss Assessments Are Completed. verbal Questions Will Not Be Accepted. All Questions Will Be Answered Through Postings To Sam.gov; Except As Provided Above. Additionally, Questions Must Not Contain Trade Secrets Or Classified Information. The Government Reserves The Right To Not Address Questions Received After 30january 2025. respondents That Submit Proprietary Data Shall Clearly Mark The Data With Appropriate Markings On The Cover Sheet And On Each Applicable Page. Any Proprietary Data Submitted May Be Handled By Contract Support Services Personnel Who Have Signed An Nda. Any Proprietary Information Received In Response To This Request Will Be Properly Protected From Any Unauthorized Disclosure. The Government Will Not Use Proprietary Information Submitted From Any One Firm To Establish The Capability And Requirements For Any Future Systems Acquisitions, So As To Not Inadvertently Restrict Competition. Any Material That Is Not Marked Proprietary Will Be Considered Publicly Releasable broad Industry Participation For This Sources Sought Is Encouraged. U.s. And Non-u.s. Firms Are Permitted To Respond To This Sss/rfi. if A Company Is Capable Of Some, But Not The Entire Requirement Stated In This Sources Sought Synopsis, Please Provide A Response That Explains The Requirements For Which You Are Capable. small Businesses Are Encouraged To Provide Responses To This Sss In Order To Assist The Program Office In Determining Potential Levels Of Competition Available In The Industry, As Well As Helping To Establish A Basis For Developing Any Subsequent Subcontracting Goals. companies Responding To This Sss/rfi Are Encouraged To Provide Quotes For Existing Items. These Quotes Are For Planning Purposes Only. indicate Whether The Company Is Currently Selling Proposed Solution To Department Of Defense Customers And Whether The Capability Can Be Obtained Under An Existing Government Contract. Provide The Contract Number(s) And Government Points Of Contact Accordingly. this Notice May Be Updated As Additional Information Becomes Available. Please Check The Sam.gov For Updates To This Announcement And Register To Receive E-mail Notices Of Any Updates.
LWG Lausitzer Wasser GmbH & Co KG Tender
Laboratory Equipment and Services
Germany
Closing Date5 Feb 2025
Tender AmountRefer Documents
Details: - 1 new construction of pumping station made from concrete shaft, diameter approx. 1.50 m, left depth approx. 5.68 m with separate cover plate with stainless steel shaft cover 1.00x1.00 m, class A, ventilation chimney including earthworks and shoring, 2 KSB pumps, foot installation, 1 knife gate valve DN 400 - 1 valve shaft made from concrete shaft, diameter approx. 1.50 m, left depth approx. 2.40 m with valves and shaped pieces including earthworks and shoring - 20 m jacking pipe PP, DN/OD 280 x 18.0; length 0.47 m with start and finish pit - 1 start shaft made from reinforced concrete or steel, diameter 2.00 m including proportional earthworks - 20 m pressure line made from PE-HD DN/OD 90x8.2, drilling through including connection to existing. DL Dn/od 160x14.6 with start and finish pit - Conversion of existing pump shaft to sewer shaft including pulling in a PKS casing pipe Dn1000 with annular space filling and new shaft cover class A - 16 m protective pipe Pe-hd Da= 76mm for electrical connection with start and finish pit - 4 bollards red/white, fixed and retractable - Over-pumping operation - Road excavation and restoration, - Groundwater management - Traffic safety
7481-7490 of 7891 active Tenders