Tenders of Dept Of The Navy Usa

Tenders of Dept Of The Navy Usa

DEPT OF THE NAVY USA Tender

Aerospace and Defence
United States
Cfengine Enterprise S/w Maintenance, Ffp, 250 Cfengine Enterprise Agents Support And Maintenance; 1 Year Pop 1/23/2025-1/22/2026 And Cf Engine Enterprise S/w Maintenance, Ffp, 250 Cfengine Enterprise Agents Support And Maintenance; 1 Year Pop 1/23/2025-1/22/2026the Purpose Of This Synopsis Is To Provide Notice Of Naval Information Warfare Center (niwc) Atlantic's Intent To Award A Firm-fixed-price Purchase Order On A Noncompetitive Basis To Northern.tech, Inc. For Cfenfine. The Government Intends To Negotiate Solely With Northern.tech, Inc. Under The Authority Of Far 13.106-1(b). There Is Only One Responsible Source And No Other Supplies Or Services Will Satisfy Agency Requirements And Under The Simplified Acquisition Threshold. The Psc Code 7a21, Naics Code Is 541519 And The Small Business Size Standard Is Small Business.this Notice Is Not A Request For Competitive Quotes; However, Any Responsible Source Believing That It Can Fulfill The Requirement May Submit A Capability Statement, Proposal, Or Quotation. Responses To The Pre-solicitation Notice Can Be Submitted Via The Navwar E-commerce Website At Navwar E-commerce Central (navy.mil) By 07 January 2025 By 3:00pm. Questions Concerning This Notice Should Be Directed To Yolanda Moore At Yolanda.v.moore.civ@us.navy.mil. All Responses Received By 07 January 2025 By 3:00pm Will Be Considered By The Government For The Purpose Of Determining Whether To Conduct A Competitive Procurement. A Determination By The Government Not To Compete The Proposed Purchase Order Based Upon Responses To This Notice Is Solely Within The Discretion Of The Government.all Responding Vendors Must Be Registered To The System For Award Management (sam). Information Can Be Found At Https://www.sam.gov. Complete Sam Registration Means A Registered Unique Entity Id And Cage.the Point Of Contact For This Announcement Is Yolanda Moore, Contract Specialist, At Yolanda.v.moore.civ@us.navy.mil. Cognizant Contracting Office: Niwc Atlantic, Po Box 190022, North Charleston, Sc 29419 – 9022.contracting Officer: Lisa Matthews
Closing Date7 Jan 2025
Tender AmountRefer Documents 

DEPT OF THE NAVY USA Tender

Others
Corrigendum : Closing Date Modified
United States
Contact Information|4|n743.49|wvb|7176052147|benjamin.t.spangler.civ@us.navy.mil| item Unique Identification And Valuation (jan 2023)|19|||||||||||||||||||| higher-level Contract Quality Requirement (navicp Review Feb 1991)(feb 1999)|1|see Specification Sections C And E.| inspection Of Supplies--fixed-price (aug 1996)|2||| variation In Quantity (apr 1984)|3|0|5|| general Information-fob-destination|1|b| wide Area Workflow Payment Instructions (jan 2023)|16|stand-alone Receiving Report - Certifications Combo - Receiving Report & Invoice - Material |n/a|tbd|n00104|tbd|n39040|n50286|tbd|133.2|n/a|n/a|n39040|n/a|n/a|see Dd Form 1423 |port_ptnh_wawf_notification@navy. mil Benjamin.t.spangler.civ@us.navy.mil| navy Use Of Abilityone Support Contractor - Release Of Offeror Information (3-18))|1|| equal Opportunity (sep 2016)|2||| warranty Of Supplies Of A Noncomplex Nature (june 2003)|6|365 Days After Acceptance Of Material|365 Days After Acceptance Of Material||||| warranty Of Data--basic (mar 2014)|2||| buy American --free Trade Agreements--balance Of Payments Program - Basic (jan2023))|3|||| notice Of Total Small Business Set-aside (oct 2020)(deviation 2020-o0008)|1|| alternate A, Annual Representations And Certifications (nov 2020)|13|||||||||||||| buy American-free Trade Agreements-balance Of Payments Program Certificate-basic (dec 2022))|3|||| buy American-balance Of Payments Program Certificate-basic (nov 2014)|1|| annual Representations And Certifications (mar 2023)|13|332312|500|||||||||||| notice Of Priority Rating For National Defense, Emergency Perpardeness, And Enrgy Progam Use (april 2008))|2||x| this Amendment Is Issued To Increase The Qty From 110 Ft To 500 Ft. \ this Amendment Is Issued To Extend The Closing Date To 02dec2024. \ 1.dd1423 Data Item A001 (inspection And Test Plan) May Be Waived If Already On File At Navsup Wss Mechanicsburg. 2. Portsmouth Nsy's Dodaac Has Changed From N00102 To N50286. Any Reference Ton00102 Within This Order Should Be Updated To N50286. 3. All Contractual Documents (i.e. Contracts, Purchase Orders, Task Orders, Delivery Orders, And Modifications) Related To The Instant Procurement Are Considered To Be "issued" By The Government When Copies Are Either Deposited In The Mail, Transmitted By facsimile, Or Sent By Other Electronic Commerce Methods, Such As Email. The Government's Acceptance Of The Contractor's Proposal Constitutes Bilateral Agreement To "issue" Contractual Documents As Detailed Here In. 4.the Following Proposed Delivery Schedule Applies: submission Of All Certification Data Cdrls 20 Days Prior To Delivery. pnsy Review/acceptance Of Certification Cdrls 6 Working Days After Receipt final Delivery Of Material (365 Days) 5.navsup Wss Mech Will Be Considering Past Performance In The Evaluation Of Offers. See Clause 252.213-7000. 6. Drawings Can Be Accessed Thru: Sam.gov 7. This Award Does Not Contain Government Source Inspection (gsi) 8. Far Clause 52.232-25(a)(5), Entitled Prompt Payment, Constructive Acceptanceis Changed From 7 Days To 45 Days After Delivery Of The Supplies In Accordance With The Terms And Conditions Of The Contract. 9. Note To Dcma Aco: Clause Navsupwssga02 Is Amended To Include Post Award Pcoretaining The Following Functions: Far 42.302(3), (32), (37), (38), (40),(41),(43), (45 Through 51), (60) And (62). 10. This Order Is Issued Pursuant To Emergency Acquisition Flexibilities (eaf). 11. Viq 0+/5- Applies To This Order. 1. Scope 1.1 The Material Covered In This Contract/purchase Order Will Be Used In A Crucial Shipboard System. The Use Of Incorrect Or Defective Material Would Create A High Probability Of Failure Resulting In Serious Personnel Injury, Loss Of Life, Loss Of Vital shipboard Systems, Or Loss Of The Ship Itself. Therefore, The Material Has Been Designated As Special Emphasis Material (level I, Scope Of Certification, Or Quality Assured) And Special Control Procedures Are Invoked To Ensure Receipt Of Correct Material. 2. Applicable Documents 2.1 Order Of Precedence - In The Event Of A Conflict Between The Text Of This Contract/purchase Order And The References And/or Drawings Cited Herein, The Text Of This Contract/purchase Order Must Take Precedence. Nothing In This Contract/purchase Order, however, Must Supersede Applicable Laws And Regulations Unless A Specific Exemption Has Been Obtained. 2.2 Applicable Documents - The Document(s) Listed Below Form A Part Of This Contract/purchase Order Including Modifications Or Exclusions. 2.2.1 "document References" Listed Below Must Be Obtained By The Contractor. Ordering Information Is Included As An Attachment To This Contract/purchase Order. 2.2.2 Specification Revisions - The Specification Revisions Listed Under "documents References" Below Are The Preferred Revision. Older And/or Newer R Evisions Are Acceptable When Listed Within Contract Support Library Reference Number Csd155 In Ecds (electric contractor Data Submission) At: Ht Tps://register.nslc.navy.mil/. This Is To Allow Contractors To Use Certain Acceptable Older Specification Revisions To Purge Their Existing Stock Of Material Certified To Those Older Revisions Or To Use Newer Specification revisions When Material Is Certified To Newly Released Revisions,without Requiring The Submittal Of Waiver/deviation Requests For Each Specification Revision On Every Contract. Revisions Of Specifications Reflecting Editorial And/or Re-approval (e.g. E2009, r2014, Etc.) Are Considered Inconsequential, But Are Acceptable When Their Revisions Are Listedwithin Csd155 Or Elsewhere Within This Contract. document Ref Data=ansi/asq Z1.4 | | | |080101|a| | | document Ref Data=qq-n-286 | | |g |001207|a| | | document Ref Data=astm-b666 | | | |201101|a| | | document Ref Data=mil-std-792 | | |f |060519|a| | | document Ref Data=mil-std-2132 | | |d |080310|a| |01| document Ref Data=sae Ams 2806 | | |c |080301|a| | | document Ref Data=sae Ams 2807 | | |a |000901|a| | | document Ref Data=sae Ams 2809 | | |a |070801|a| | | document Ref Data=iso_9001 | | | |081115|a| | | document Ref Data=sae Ams-std-185 | | | |000901|a| | | document Ref Data=iso10012 | | | |030415|a| | | document Ref Data=iso/iec 17025 | | | |050515|a| | | document Ref Data=mil-i-45208 | | |a |810724|a| 1| | document Ref Data=mil-std-45662 | | |a |880801|a| | | document Ref Data=ansi/ncsl Z540.3 | | | |130326|a| | | document Ref Data=t9074-as-gib-010/271 | | |1 |140911|a| | | 3. Requirements 3.1 Manufacture And Design - The Item Furnished Under This Contract/purchase Order Must Meet The Requirements As Specified In Qq-n-286 Except As Amplified Of Modified Herein. Qq-n-286 Ordering Data Information Is Provided Below: a. Nickel-copper-aluminum Alloy, Wrought (uns N05500); Qq-n-286. b. Form - ;2; Condition - ;annealed (hot Finished Or Cold Drawn) And Age Hardened; Surface Finish - As Specified In Paragraph 4.3.3.1.3 Of Qq-n-286. c. Specification Revision Levels Must Be As Specified Elsewhere In The Contract/purchase Order. d. Forging Sketches Are Not Applicable. e. Size - ;2 Inches (round); f. Product Check Analysis Is Not Required. g. Forging Rings And Discs Are Not Applicable. h. Tolerances Must Be As Specified In Qq-n-286. i. Optional Ultrasonic Inspection Is Required. Certification Is Required. j. Optional Liquid Penetrant Inspection Is Required On Cold Worked Material Only. k. Length - Under 5" Dia. = 8 Feet Min / 12 Feet Max (plus Or Minus 10%) 5" Dia & Over = 5 Feet Min / 12 Feet Max (plus Or Minus 10%) Or As Specified Elsewhere In The Contract/purchase Order. l. Paragraph 3.9.1.3.1 Of Qq-n-286 Applies Unless Otherwise Specified. m. Edges Must Be As Specified In Paragraph 3.9.1.4 Of Qq-n-286. n. Forging Dimensions Are Not Applicable. o. Marking Must Be As Specified Elsewhere In The Contract/purchase Order. p. All Unaged Barstock Must Be Supplied In The Annealed Condition And Be Subjected To A Capability Test. q. Age Hardening Must Be Performed In Accordance With Paragraph 4.3.2.2.1, Unless Otherwise Specified. r. The Final Heat Treatment Procedure Must Be In Accordance With Qq-n-286, Unless Otherwise Specified. s. The Slow Strain Rate Tensile Test Must Be Conducted By One Of The Laboratories Identified Below. t. Level Of Preservation, Packaging, And Packing Must Be As Specified Elsewhere In The Contract/purchase Order. 3.2 Bar, Pipe, And Tube Quantities - When This Order Results In Supplying Fewer Than 5 Pieces As Defined In The "length" Paragraph Above, All Material Must Be From A Single Heat Of Material. 3.3 Testing Certification - Certifications Are Required For The Following Tests On The Items Listed Below. Additional Testing (if Any) Per Applicable Specifications Is Still Required, But Certifications Are Only Required As Listed Below. test - Ultrasonic Inspection On Starting Material item - ;each Bar; performance - T9074-as-gib-010/271 Or Mil-std-2132, And Qq-n-286 acceptance - Qq-n-286 test - ;macroetch Test (duplex Grain Structure); item - ;bar, Metal; performance - ;qq-n-286; acceptance - ;qq-n-286; test - Dye Penetrant Inspection (100% Coverage) item - Each Metal Bar (cold Worked/cold Finished) performance - T9074-as-gib-010/271 acceptance - Qq-n-286 attribute - Annealing And Age Hardening item - ;bar, Metal; performance - Qq-n-286 3.4 Slow Strain Rate Tensile Test Laboratories - The Slow Strain Rate Tensile Test Of Qq-n-286 Must Be Performed By One Of The Following Laboratories: huntington Alloys, A Special Metals Company attn: Bill Bolenr 3200 Riverside Drive huntington, Wv 257059 phone: (304) 526-5889 fax: (304) 526-5973 metallurgical Consultants, Inc. attn: W. M. Buehler 4820 Caroline po Box 88046 houston, Tx 77288-0046 phone: (713) 526-6351 fax: (713) 526-2964 naval Surface Warfare Center, Carderock Division attn: Eric Focht Code 614 9500 Macarthur Blvd west Bethesda, Md 20817-5700 phone: (301) 227-5032 fax: (301) 227-5576 teledyne Allvac attn: Dr. W. D. Cao 2020 Ashcraft Ave. monroe, Nc 28110 phone: (704) 289-4511 fax: (704) 289-4269 westmoreland Mechanical Testing And Research Inc. attn: Andrew Wisniewski p.o. Box 388 youngstown, Pa 15696-0388 mannesmann Rohrenwerke mannesmann Forschungsinstitut (mfi) attn: Dr. Weiss postfach 251160 47251 Duisburg germany phone: 011-49-0203-9993194 fax: 011-49-0203-9994415 thyssenkrupp Vdm Usa, Inc. attn: D. C. Agarwal 11210 Steeplecrest Drive, Suite 120 houston, Tx 77065-4939 phone: (281) 955-6683 3.5 Certificate Of Compliance - (special Emphasis Material) The Contractor Must Prepare And Submit A Certificate Of Compliance Certifying That The Items/components Furnished Under This Contract Comply With The Requirements Of The Procurement Document, including Any/all Invoked Specifications And Drawings. 3.6 Configuration Control - The Contractor Must Maintain The Total Equipment Baseline Configuration. For Items Of Proprietary Design, Contractor Drawings Showing The Latest Assembly Configuration Must Be Provided To The Government Inelectronic (c4) Format. definitions Are Provided Elsewhere In The Contract/purchase Order. 3.6.1 Waivers/deviations - All Waivers And Deviations, Regardless Of Significance Or Classification Require Review And Approval By The Contracting Officer. Waivers And Deviations Must Be Designated As Critical, Major, Or Minor. Requests Must Include The information Listed Below. a. A Complete Description Of The Contract Requirement Affected And The Nature Of The Waiver/deviation (non-conformance), Including A Classification Of Critical, Major, Or Minor. b. Number Of Units (and Serial/lot Numbers) To Be Delivered In This Configuration. c. Any Impacts To Logistics Support Elements (such As Software, Manuals, Spares, Tools, And Similar) Being Utilized By Government Personnel Or Impacts To Theoperational Use Of The Product. d. Information About Remedial Action Being Taken To Prevent Reoccurrence Of The Non-conformance. 3.6.2 Requests For Waivers/deviations For Navsup-wss Contracts Must Be Submitted Using The Ecds (electronic Contractor Data Submission) System At Https://register.nslc.navy.mil/ 3.6.3 Ecps - The Government Will Maintain Configuration Control And Change Authority For All Modifications Or Changes Affecting Form, Fit, Function, Or Interface Parameters Of The Equipment And Its Sub-assemblies. The Contractor Must Submit An Engineering change Proposal (ecp) For Any Class I Or Ii Changes That Impact The Equipment Covered By This Contract. Ecps Must Be Prepared In Contractor Format, And Must Include The Following Information: a. The Change Priority, Change Classification (class I Or Class Ii), And Change Justification. b. A Complete Description Of The Change To Be Made And The Need For That Change. c. A Complete Listing Of Other Configuration Items Impacted By The Proposed Change And A Description Of The Impact On Those Cis. d. Proposed Changes To Documents Controlled By The Government. e. Proposed Serial/lot Number Effectivities Of Units To Be Produced In, Or Retrofitted To, The Proposed Configuration. f. Recommendations About The Way A Retrofit Should Be Accomplished. g. Impacts To Any Logistics Support Elements (such As Software, Manuals, Spares, Tools, And Similar) Being Utilized By Government Personnel In Support Of Theproduct. h. Impacts To The Operational Use Of The Product. i. Complete Estimated Life-cycle Cost Impact Of The Proposed Change. j. Milestones Relating To The Processing And Implementation Of The Engineeringchange. 3.7 Mercury Free - Mercury And Mercury Containing Compounds Must Not Be Intentionally Added Or Come In Direct Contact With Hardware Or Supplies Furnished Under This Contract. Mercury Contamination Of The Material Will Be Cause For Rejection. ^ Quality Assurance Requirements ^ 3.8 See Cdrl Di-misc-80678 (test Certification) - A Statement Of Tests Performed, Listing The Pieces Tested Must Be Furnished Along With A Copy Of The Test Results. Certification Must Include The Contractor's Name, Address And Date, Quantity Inspected, identified To The Contract/purchase Order And Item Number, And The Contractor's Or Authorized Personnel's Signature. Test Certifications Must Reference The Standard/specification, Including The Revision, To Which The Testing Was Performed And The Acceptance criteria Used. Test Procedure Numbers May Also Be Referenced On Test Reports. Test Reports On Weldments Must Be Identified To Weld Joint And Layer. 3.9 Quality System Requirements - The Contractor Furnishing Items Under This Contract/purchase Order Must Provide And Maintain A Quality System In Accordance With Iso-9001 As Amplified Or Modified Herein, With The Calibration System Requirements Of Iso-10012 or Ansi-z540.3 With Iso-17025. A Quality System In Accordance With Mil-i-45208, With The Calibration System Requirements Of Mil-std-45662, Is Acceptable As An Alternate. 3.9.1 The Contractor's Quality System And Products Supplied Under The System Are Subject To Evaluation, Verification Inspection, And Acceptance/nonacceptance By The Government To Determine The System's Effectiveness In Meeting The Quality Requirements established In The Contract/purchase Order. 3.9.2 The Contractor's Quality System Must Be Documented And Must Be Available For Review By The Contracting Officer Prior To Initiation Of Production And Throughout The Life Of The Contract. The Prime Contractor Must, Upon Notification, Make His Facilities available For Audit By The Contracting Officer Or His Authorized Representative. 3.9.3 See Cdrl Di-qcic-81110 (inspection System Procedures) - All Suppliers Of Level I/subsafe (li/ss) Material Are Required To Submit A Copy Of Their Current Documented Quality System Procedures To The Procurement Contracting Officer (pco) Prior To Award Of any Contract/purchase Order. Suppliers That Have A Copy Of Their Current Quality System Procedures On File At The Procuring Activity May Request The Pco Waive This Requirement. 3.9.4 This Contract Provides For The Performance Of Government Quality Assurance At Destination. The Place Or Places Of Performance May Not Be Changed Without The Authorization Of The Procurement Contracting Officer. 3.9.5 Any Changes Made By The Contractor To A Qualified Quality System Will Require Re-submittal To The Pco. 3.10 Contractor Inspection Requirements - The Contractor Must Maintain Adequate Records Of All Inspections And Tests. The Records Must Indicate The Nature And Number Of Observations Made, The Number And Type Of Deficiencies Found, The Quantities Approved And rejected And The Nature Of Corrective Action Taken As Appropriate. Inspection Records Must Be Traceable To The Material Inspected. 3.10.1 The Supplier's Gages, Measuring And Test Equipment Must Be Made Available For Use By The Government When Required To Determine Conformance With Contract Requirements. When Conditions Warrant, The Supplier's Personnel Must Be Made Available For operations Of Such Devices And For Verification Of Their Accuracy And Condition. 3.10.2 All Documents And Reference Data Applicable To This Contract Must Be Available For Review By The Government. Copies Of Documents Required For Government Inspection Purposes Must Be Furnished In Accordance With The Instructions Provided By The government. 3.11 Subcontractor Inspection Requirements - The Government Has The Right To Inspect At Source, Any Supplies Or Services That Were Not Manufactured Or Performed Within The Contractor's Facility. Any Purchasing Documents To A Subcontractor Must Cite The applicable Portions Of The Contractually Invoked Quality System (e.g. Calibration Requirements), Plus Any Product Requirements That Apply To The Supplies Being Purchased. When The Government Elects To Perform Source Inspection At The Subcontractor's Facility, applicable Purchase Documents Must Be Annotated With The Following Statement: "a Government Inspection Is Required Prior To Shipment From Your Plant. Upon Receipt Of This Order, Promptly Notify The Prime Contractor Who Will Notify The Pco So That Appropriate planning For Government Inspection Can Be Accomplished. 3.11.1 The Prime Contractor's Program Must Include Procedures To Assess The Capability Of The Prospective Suppliers To Produce The Products Or Supply The Services In Accordance With The Contract, Prior To The Issuance Of Any Purchase Document. 3.11.2 Each Sub-tier Supplier Of Material Or Services For Items In Section 3 Of This Contract Must Be Subjected To A Periodic Review Or Audit By The Prime To Determine The Continued Capability Of The Supplier To Control The Quality Of The Products Or Services specified In The Purchase Order Or Contract. 3.11.3 The Prime Contractor Must Ensure That The Purchased Product Conformsto Specified Purchase Requirements And This Contract. The Type And Extent Of Control Applied To The Supplier And The Purchased Product Must Be Dependent Upon The Effect Of The purchased Product On The End Item Represented By This Contract. 3.11.4 The Prime Contractor Must Evaluate The Requirements Of The Contractand Select Suppliers Based On Their Ability To Supply The Product In Accordance With The Prime Contractor's Requirements And The Contract. Criteria For Selection And Evaluation Must Be established. Records Of This Effort Must Be Available For Review By The Government. 3.11.5 The Prime Contractor's Supplier Quality Assurance Program Must Provide For A Review Of Purchase Documents To Assure Applicable Quality Requirements Are Included Or Referenced In The Documentation For Compliance By The Supplier. 3.12 Government Furnished Material And/or Equipment (gfm/gfe) - When Material Or Equipment Is Furnished By The Government, The Contractor Must Develop Documented Control Procedures That Require At Least The Following: 3.12.1 Visual Examination Upon Receipt To Detect Damage During Transit. 3.12.2 Inspection For Completeness And Proper Type. 3.12.3 Verification Of Material Quality Received. 3.12.4 Periodic Inspection And Precautions To Assure Adequate Storage Conditions And To Guard Against Damage From Handling And Deterioration During Storage. 3.12.5 Functional Testing, Either Prior To Or After Installation, Or Both, As Required By The Contract To Determine Satisfactory Operation. 3.12.6 Identification And Protection From Improper Use Or Disposition. 3.12.7 Reporting To The Government, Any Gfm Or Gfe Property Found Damaged, Malfunctioning, Or Otherwise Unsuitable For Use. In The Event Of Damage Or Malfunction During Or After Installation, The Supplier Must Determine And Record Probable Cause And necessity For Withholding The Material From Use. 3.12.8 For Gfe Material, And As Required By The Terms Of The Bailment Agreement, The Supplier Must Establish Procedures For Adequate Storage, Maintenance, And Inspection Of Bailed Government Material. Records Of All Inspection And Maintenance Performed On bailed Property Must Be Maintained. 3.12.9 Material Returned To The Contractor Must Be Handled As Gfm. 3.13 Traceability And Certification Requirements - To Assure That Correct Materials Are Installed In Level I/subsafe Systems, It Is Imperative That Traceability Be Maintained From The Material To The Material Certification Test Report And Other required Objective Quality Evidence (oqe). The Material Certification Report Must Completely And Accurately Reflect That The Material Supplied Meets The Specified Requirements. Materials Requiring Traceability And Certification Data Are Identified Within paragraph 3, Section C Of This Contract/purchase Order. 3.13.1 The Following Provides The Minimum Requirements For Maintaining Material Traceability And Supplements The Requirements Specified In Di-misc-81020 And Elsewhere In The Contract/purchase Order. The Contractor Must Develop Written Procedures That implement The Material Control Requirements Stated Herein And Elsewhere In The Contract/purchase Order. 3.14 Material Traceability - The Certification Data Report Must Be Identified Through A Unique Traceability Number, Heat-lot Number, Or Heat-treat Number, As Applicable, Which Must Also Be Marked On The Material. This Traceability Marking On The Material Must provide Direct Traceability To The Material's Chemical Composition And Mechanical Properties Certification Data. For Material Produced By Batch, Continuous Cast, Or Continuous Pour Processes, Samples Must Be Taken No Less Than Once In Every Eight Hours Of operation For The Purpose Of Validating Proper Chemical Composition And Mechanical Properties. Traceability Must Be Maintained Through All Process Operations Including Any Subcontracted Operations, To The Finished Component. 3.15 Material Marking For Traceability And Identification - The Following Are The Minimum Marking Requirements. In Addition To The Marking Requirements On Applicable Specifications, Marking For Traceability Is Required. Pipe, Tube, And Metal Bar Must Have both Permanent Marking And Temporary Marking Applied As Specified Below. 3.15.1 Permanent Marking - Permanent Traceability Marking Must Be Marked On Each End Of Each Pipe, Tube, And Metal Bar. (monel And K-monel Bar: 3/4 Inch To 1 Inch Rods, And 7/8 Inch Hex Bar May Be Marked On The Surface Near The End Of Bar/rod, And Rod Less than 3/4 Inch And Hex Bar Less Than 7/8 Inch May Be Bundled And Tagged Or Boxed With The Traceability Marking On The Tag Or Box.) All Traceability Marking Must Be Permanently Applied In Accordance With Mil-std-792. An Alternate Marking Method Is Permissible provided It Is An Available Option In The Contractually Invoked Specification, Except In Instances Where The Material Has Been Modified By This Contract/purchase Order, And Differs From That Specified In The Specification. Electric Arc Marking Or Impression marking Is Strictly Prohibited On Thin Wall Tubing. (wall Thickness Of Less Than 0.125 Inch). 3.15.2 Temporary Marking - Temporary Marking Must Consist Of: name Or Trademark Of Manufacturer, Specification And Grade (as Applicable), Size, Contract Number, And The Traceability Marking. Pipe And Tube Marking Must Also Include Sml (for Seamless). Marking Must Be In Accordance With The Material Specification And sae-ams-2806, Sae-ams-2807, Sae-ams-2809, Table I Of Sae-ams-std-185, Or Astm-b666 As Applicable. Application Must Be In Accordance With Mil-std-792, Type A (temporary Ink Stenciling). An Alternate Method Is Permissible For Monel And K-monel Bar Provided It is An Available Option (temporary Marking Only) In The Applicable Material Specification, Except That Hot Finished Rod With Rough Ground Surface 3/4 Inch And Under May Be Bundled And Tagged Or Boxed With The Traceability Marking On The Bag Or Box. contamination Levels For Ink Stenciling Must Be As Outlined In Paragraph 5.2 Of Mil-std-792. 3.16 See Cdrl Di-misc-81020 (chemical And Mechanical) - Material Certification - In Addition To The Certification Data Requirements Specified In Di-misc-81020, The Following Material Certification Requirements Apply: 3.16.1 Quantitative Chemical And Mechanical Analysis Of Material Traceable To Traceability Markings Is Required. Material Certification Test Reports Must Include The Class, Form, Condition, Grade, Type, Finish, And/or Composition, As Applicable, Of The material Supplied. 3.16.2 Re-identification And Re-certification Of Material Is Required When The Material Is Subjected To A Process Which Alters It's Properties. If The Starting Material Or Raw Stock Is Processed In A Manner That Will Not Affect Its Chemical Composition Or mechanical Properties, The Original Certifications For The Chemical Composition And Mechanical Properties, As Required By The Material Specification, Are Acceptable. Re-certification Of The Chemical Or Mechanical Properties Is Required If A Process Is Used during Fabrication That Alters The Original Properties Of The Material (e.g. Alloying, Heat Treating, Or Forming). In These Instances, The Properties Of The Material Must Be Re-determined And Documented To Reflect The Altered Condition. The Altered Material must Be Uniquely Re-identified. The Properties Thus Determined And Documented, Are Required For Final Certification And Must Conform To The Material Specification Or The Contract/purchase Order Requirements. When Only The Mechanical Properties Are Altered, The original Certification Forchemical Composition Must Be Overstamped And Annotated With The Unique Traceability Marking Used With The Altered Material And At A Minimum Contain The Information Below. traceability Marking ________________________________________________ (marking On Finished Item) is Fabricated From Raw Material Identified To heat/lot Number ______________ And Heat Treat Number ______________________ (when Applicable) _________________________________________ Date _____________________ (name And Signature Of Auth. Co. Rep.) 3.16.3 Material Certification Data Forwarded By The Manufacturer Must Contain A Signed Certification That The Report Results Represent The Actual Attributes Of The Material Furnished And Indicate Full Compliance With All Applicable Specification And Contract requirements. Transcription Of Certification Data Is Prohibited. 3.16.4 Statements On Material Certification Documents Must Be Positive And Unqualified. Disclaimers Such As "to The Best Of Our Knowledge" Or "we Believe The Information Contained Herein Is True" Are Not Acceptable. 3.16.5 If Material Is Received Without The Required Certification Papers Or With Incorrect/missing Data On The Certification Papers, The Material Will Be Rejected. 3.17 Material Handling - The Written Material Control Process Must Include The Following: 3.17.1 All Raw Materials Must Have Traceability Markings (except As Specified Below). 3.17.2 Stored Raw Materials Requiring Traceability Must Be Segregated To Preclude Intermingling With Materials Not Requiring Traceability. 3.17.3 When Traceability Markings Will Be Removed By A Manufacturing Or Fabrication Process, The Marking Must Be Recorded Prior To Removal And Be Immediately Restored Upon Completion Of The Process. If This Cannot Be Done Or Is Impractical, An Appropriate material Control Procedure (such As A Bag And Tag, Tagging, And/or Tote Box Control) Must Be Employed. The Material Control Procedure Must Provide A Method Of Positive Control To Preclude Commingling Of Heats/lots Or Loss Of Traceability. The Traceability marking Must Be Reapplied Upon Completion Of The Final Manufacturing Process. 3.17.4 Purchase Orders For Raw Material Must Specify That The Material Be Traceable To Material Certification Test Reports By Traceability Markings On The Material And Identified On The Test Reports. The Certification Data Requirements Contained In di-misc-81020 Must Be Invoked By The Prime Contractor On All Subcontractors Supplying Level I Material. 3.17.5 The Material Control Process Must Include Requirements For The Maintenance Of Traceability For Items Sent Out For Subcontracted Operations. If Such Operations Would Remove Traceability Markings, Purchase Or Work Orders Must Specify A Method And Marking location For Remarking. The Contractor Must Also Ensure That Subcontractor Production Controls Are Adequate To Preclude Commingling Of Materials During Processing. 3.18 Receiving Inspection - 3.18.1 Products And Services Produced By Sub-tier Suppliers For Incorporation In The Contract End Item Must Be Subject To Inspection Or Audit At The Time Of Receipt By The Prime Prior To Further Processing Within The Prime Contractor's Plant Or Shipment To another Location. 3.18.2 Receiving Inspection Must Include As A Minimum - verification That The Traceability Marking On The Material Agrees With That On The Certification Test Reports. verification That Certification Test Reports Are Legible And Complete. verification That The Contents Of The Certification Test Reports Are In Compliance With The Contractually Invoked Specifications And Requirements. 3.19 Discrepancy Reporting - 3.19.1 Nonconforming Products From Sub-tier Suppliers Must Be Identified And Processed In Accordance With The Prime Contractor's Procedures For Controlling Nonconforming Products. The Prime Contractor Must Report The Receipt Of Any Nonconforming Products To the Responsible Sub-tier Supplier In Accordance With Established Procedures. Nonconforming Material Records Must Be Maintained And Available For Review By The Government. 3.20 Final Inspection - The Following Inspections Must Be Performed Prior To Government Inspection And Acceptance. 3.20.1 Material Sampling - Material Must Be Inspected For Form, Fit, And Function. Lot Acceptance Must Be Based On Zero Defects And Lot Rejection Based On One Defect. The Sample Size Must Be In Accordance With The Sampling Plan(s) In The Applicable Military specification Or Standard, Federal Specification Or Standard, Or Drawing To Which The Material Was Manufactured. In The Absence Of Such Sampling Plans, Sampling Inspection Must Be Per Ansi/asq-z1.4, General Inspection Level Ii (for Sample Size Selection Code), table Iia (for Sample Size). small Lot Sizes - For Lot Sizes Of Fifty Or Less, The Minimum Sample Size Must Be Eight Units. For Lot Sizes Of Eight Or Less, The Sample Size Must Be One Hundred Percent Of The Lot. 3.20.2 The Manufacturer May Elect To Use Statistical Process Control (spc) To Assure Product Quality In Lieu Of The Above Attribute Sampling Plan, Provided That The Spc Methodology/system Used Provides Acceptable Products To The Government. However, The government/navy Receipt Inspection Activity May Perform Their Acceptance Inspection Of The Material Using The Attribute Sampling Plan Outlined Above. 3.20.3 All Data Concerning Material Verification (chemical, Mechanical Or Physical Properties), Traceability (material Certifications To Material Marking), And Nondestructive Test (ndt) Certifications For Material Must Be 100% Inspected. The Certification test Reports Must Also Be 100% Inspected For Completeness And Legibility. 3.20.4 All Material Requiring Traceability Must Be 100% Inspected For Traceability Marking And That The Marking Is Legible. 3.21 See Cdrl Di-misc-80678 (special Emphasis C Of C) - The Certificate Of Compliance Must Show Traceability To The Marking Applied On Each Individual Item, And Must Contain The Following Information: 1. Contractor's Name, Address And Date. 2. The Contract/purchase Order Number (for Example: N00104-11-p-fa12) 3. The National Stock Number (nsn). The 18 Character National Stock Number For Special Emphasis Material Includes The Two Digit Cog, The Four Digit Fsc, The 9 Digit Niin, And The Two Digit Smic (for Example: 1h 4820 012345678 L1) ("n/a" When Not Applicable). 4. Lubricants, Sealants, Anti-seize, And/or Thread Locking Compounds ("n/a" When Not Applicable). 5. Certification That O-rings, Packing, Gaskets, Or Other Elastomeric Products Were Installed In A Compressed State Within An Assembly Or Sub-assembly, Prior To Expiration Of The Shelf Life ("n/a" When Not Applicable). 6. Manufacturer's Compound Number ("n/a" When Not Applicable). 7. When Weld Procedure Submittal Is Required By The Contract, A Statement That The Approval Date Of The Qualification Data Precedes Any Production Or Repair Welding Performed On This Contract. ("n/a" When Not Applicable). 8. A Statement To The Effect That All Items Furnished On This Contract Are In Full Compliance With The Specifications And Requirements And List Each Contractually Invoked Conformance/compliance Test Performed By Name And That It Was Performed satisfactorily. 9. Contractor's Or Authorized Personnel's Signature. 4. Quality Assurance 4.1 Notes To The Contractor - 4.1.1 The Contractor For Proprietary Designs - Departures From Contractor Imposed Requirements, Not Specifically Covered By The Contract, Must Be Judged Individually On The Basis Of The Effect, If Any, On Contractual Requirements. The Departure Must Be considered A Nonconformance And Be Submitted To The Pco For Disposition. 4.1.2 The Contractor For Proprietary Designs - All Records Of Departures From Contractor Imposed Requirements Must Be Maintained And Available For Review At The Contractor's Facility. A Record Of These Departures, Traceable To The Applicable Part Number And contract Number Must Be Submitted To The Pco. 4.1.3 The Contractor For Proprietary Designs - For Proprietary Designs, The Contractor's Part Numbers Are Acceptable For Reference Only. The Delivered Material Must Conform To All Drawings, Specifications, And Other Contractual Requirements. 4.1.4 The Contractor - The Ecds (electronic Contractor Data Submission) System Is Available For Certain Data Submissions, And To Submit Questions And Clarifications, And Waiver Requests On Contracts And Solicitations. Ecds Can Be Found At: https://register.nslc.navy.mil/ 5. Packaging 5.1 Preservation, Packaging, Packing And Marking - Preservation, Packaging, Packing And Marking Must Be In Accordance With The Contract/purchase Order Schedule And As Specified Below. mil-std 2073 Packaging Applies As Found Elsewhere In The Schedule 6. Notes 6.1 Several Definitions Of Terms That Apply To Csi Items Are Listed Below. All Terms May Not Apply To Every Item. 6.1.1 The Ecds (electronic Contractor Data Submission) System Is At: Https://register.nslc.navy.mil/ This Application Will Require Advance Registration Using A Pki Digital Certificate On A Cac. A Vendor User Guide Is Available As Csd001 In The Csd (contract Support Document) Library Within Ecds. 6.1.2 Critical Safety Item (csi) - Any Ship Part, Assembly, Or Support Equipment Containing A Critical Characteristic Whose Failure, Malfunction, Or Absence Of Which Could Cause A Catastrophic Or Critical Failure Resulting In Loss Of, Or Serious Damage To The ship, Or Unacceptable Risk Of Personal Injury Or Loss Of Life. 6.1.3 Critical Process - As Determined By The Twh, Any Process, Operation Or Action Performed On A Ship Csi That Serves To Establish A Critical Characteristic (such As Welding, Soldering, Machining, Polishing, Cleaning, Or Assembling) Or Confirm That A critical Characteristic Is Within Drawing Or Specification Compliance (such As, Testing, Measurement, Or Non-destructive Evaluation). 6.1.4 First Article - Pre-production Models, Initial Product Samples, Test Samples Produced To Ensure A Manufacturer's Capability To Meet Full Specification Requirements. 6.1.5 First Article Test (fat) - Contractually Required Testing And Inspection Of A Supplier's Pre-production, Production, Or "production Representative" Specimens To Evaluate A Manufacturer's Ability To Produce Conforming Product Prior To The Government's commitment To Receive Subsequent Production Items. First Article Testing Is Product Specific And Does Not Assess Manufacturing Process Controls Nor Does It Assure The Effectiveness Of The Manufacturer's Quality Program. 6.1.6 Objective Quality Evidence (oqe) - The Quantitative And Qualitative Data Of All Mechanical, Chemical, And Performance Tests Performed (as Required By The Applicable Specification, Drawing, Or Purchase Document) To Prove That He Material Supplied conforms To The Specified Requirements. 6.1.7 Surface Discontinuity - Any Surface Irregularity, Marking, Or Localized Change In Physical Character Of The Surface, Other Than Dimensional, That Exists Infrequently At One Or Several Places. (examples: Burrs, Dents, Nicks, Scratches, Gouges, Pits, center-punches, Scribes, And Tool Marks). Surface Discontinuities Less Than 0.005-inch In Depth Are Acceptable Provided They Do Not Violate Any Other Design Requirements Specified In This Contract/purchase Order. 6.1.8 Traceability Code - A Code Or Number Providing Traceability To The Actual Chemical And Mechanical Properties Of The Specified Heat, Batch, Or Form From Which The Material Originated. 6.1.9 Verification - An Examination Performed To Determine Compliance With A Specific Requirement. 6.1.10 A Nonconformance Is Defined As Affecting Or Violating The Following: - The Requirements Of This Contract/purchase Order. - Contractually Invoked Drawings (i.e. Envelope Dimensions, Interface Dimensions With Mating Parts/equipment, Center Of Gravity, Weights, Piece Part Identification, Material, Etc.). - Contractually Invoked Federal, Military, Or Commercial Specifications And/or Standards. - Form, Fit, Function, Performance To Contract Requirements, Reliability, Maintainability, Interchangeability, Safety Of Personnel Or Equipment, Or Additional Cost To The Government. 6.1.11 Waiver - A Written Authorization To Accept An Item, Which During Manufacture, Or After Having Been Submitted For Government Inspection Or Acceptance, Is Found To Depart From Specified Requirements, But Nevertheless Is Considered Suitable For Use As Is or After Repair By An Approved Method. 6.1.12 Deviation - A Specific Written Authorization (granted Prior To The Manufacture Of An Item) To Depart From A Particular Requirement(s) Of An Item's Current Approved Configuration Documentation For A Specific Number Of Units Or A Specified Period Of time, And To Accept An Item Which Is Found To Depart From Specified Requirements, But Nevertheless Is Considered Suitable For Use "as Is" Or After Repair By An Approved Method. 6.1.13 Critical Waiver/deviation - This Waiver/deviation Consists Of A Departure Involving Safety. 6.1.14 Major Waiver/deviation - This Waiver/deviation Consists Of A Departure Involving: - Performance - Interchangeability, Reliability, Survivability, Maintainability, Or Durability Of The Item Or Its Repair Parts - Health Or Safety - Effective Use Or Operation - Weight, Stability, Or Structural Integrity - System Design Parameters As Schematics, Flows, Pressures Or Temperatures - Compartment Arrangements Or Assigned Function 6.1.15 Minor Waiver/deviation - This Waiver/deviation Consists Of A Departure Which Does Not Involve Any Of The Factors Listed As Critical Or Major. 6.1.16 Engineering Change (ec) - A Change To The Current Approved Configuration Documentation Of A Configuration Item At Any Point In The Life Cycle Of The Item. 6.1.17 Engineering Change Proposal (ecp) - A Proposed Engineering Change And The Documentation By Which The Change Is Described, Justified, And Submitted To The Government For Approval Or Disapproval. 6.2 In Accordance With Opnavinst 5510.1 All Documents And Drawings Provided By The U.s. Navy To Perspective Contractors Must Include A "distribution Statement" To Inform The Contractor Of The Limits Of Distribution, And The Safeguarding Of The Information contained On Those Documents And Drawings. 6.2.1 There Are 7 (seven) Separate Distribution Statement Codes Used For Non-classified Documents And Drawings. The Definition For Each Is As Follows: a... Approved For Public Release; Distribution Is Unlimited. b... Distribution Authorized To Us Governments Agencies Only. c... Distribution Authorized To Us Government Agencies And Their Contractors. d... Distribution Authorized To Dod And Dod Contractors Only. e... Distribution Authorized To Dod Components Only. f... Further Distribution Only As Directed By Commander, Naval Sea Systems Command, Code 09t. x... Distribution Is Authorized To Us Government Agencies And Private Individuals Or Enterprises Eligible To Obtain Export Controlled Technical Data In Accordance With Opnavinst 5510.161. 6.3 Ordering Information For Document References - The Department Of Defense Single Stock Point (dodssp), Website Http://www.dsp.dla.mil/, Provides Product Information For The Department Of Defense Index Of Specifications And Standards (dodiss) (i.e.military/federal Specifications And Standards), Data Item Descriptions (dids), And Other Dodssp Products. Most Specifications Can Obtained Directly From Http://quicksearch.dla.mil/ a. Availability Of Cancelled Documents - The Dodssp Offers Cancelled Documentsthat Are Required By Private Industry In Fulfillment Of Contractual Obligationsin Paper Format. Documents Can Be Requested By Phoning The Subscription Services Desk. b. Commercial Specifications, Standards, And Descriptions - These Specifications, Standards And Descriptions Are Not Available From Government Sources. Theymay Be Obtained From The Publishers Of The Applicable Societies. c. Ordnance Standards (os), Weapons Specifications (ws), And Navord Ostd 600 Pages - These Type Publications May Be Obtained By Submitting A Request To: commander, Indian Head Division, Naval Surface Warfare Center code 8410p, 101 Strauss Avenue indian Head, Md 20640-5035 d. On Post-award Actions, Requests For "official Use Only" And "noforn" (not Releasable To Foreign Nationals) Documents Must Identify The Government Contractnumber, And Must Be Submitted Via The Cognizant Defense Contract Management Command (dcmc) For certification Of Need For The Document. On Pre-award Actions Such Requests Must Be Submitted To The Pco For Certification Of Need For The Document. e. Noforn Military Specifications And Standards (including Amendments, Change Notices And Supplements, But Not Interim Changes) To Be Ordered From: contracting Officer navsup-wss code 87321 5450 Carlisle Pike p.o. Box 2020 mechanicsburg, Pa. 17055-0788 f. Nuclear Reactor Publications Assigned Navsea Documents And Identification Numbers (i.e. Navsea Welding Standard, Navsea 250-1500-1) Are To Be Ordered Enue: commanding Officer navsup-wss code 009 5450 Carlisle Pike p.o. Box 2020 mechanicsburg, Pa. 17055-0788 g. Technical Manuals Assigned Navsea Identification Numbers (i.e. Navsea Welding And Brazing Procedure, Navsea S9074-aq-gib-010/248) Are To Be Ordered From: commanding Officer navsup-wss code 1 Support Branch 700 Robbins Avenue philadelphia, Pa. 19111-5094 h. Interim Changes And Classified Specifications Must Be Obtained By Submitting A Request On Dd Form 1425 To Navsup-wss. 6.4 Recent Updates - A Short Description Of Recent Updates To The Technical Requirements Of This Item Are Listed Below, Along With An Implementation Date For Each Issue. The Notes Below Are Only A Generic Quick Reference And Are Provided For Convenience only, Detailed Requirements Will Be Defined Elsewhere In The Technical Sections Of This Contract/purchase Order. ;10/20/2016 - Updated Ecds Url - Jun 28 2012 - Updated Ut Of Qq-n-286 Bar 4" And Over - Dec 17 2011 - Moved Quality Assurance Text Location For Readability - Apr 15 2009 - Clarified The Sample Size For Large And Small Lot Sizes - Jan 19 2011 - Added Notification Of Dcma Upon Contract Award - May 02 2009 - Added Lubricants And Sealants To The C Of C - Aug 27 2014 - Took Out Contractor's Phone Number Requirement - May 16 2013 - Removed Gsi From This Material. - Jan 5 2017 - Ecds/csd Info Was Added To Definitions In The Notes Section.; date Of First Submission=asreq paragraph 10.4 Of Di-qcic-81110 Does Not Apply. date Of First Submission=asreq block 12 - Certification Data Must Be Submitted To Portsmouth Naval Shipyard For Review And Acceptance Prior To Each Shipment Of Material. Certification Documentation Must Be Submitted Via Wawf (wide Area Work Flow). enter In Wawf As Follows: "ship To" N50286 "inspect By" N39040 "accept By" N39040 and Email Notification Field: Port_ptnh_wawf_notification@navy.mil no Material Is To Be Shipped Prior To The Receipt Of Acceptance. date Of First Submission=asreq block 4 - Paragraphs 10.2.1, 10.2.2, 10.2.3, 10.3, And 10.4 Of Di-misc-80678 Do Not Apply. block 12 - Certification Data Must Be Submitted To Portsmouth Naval Shipyard For Review And Acceptance Prior To Each Shipment Of Material. Certification Documentation Must Be Submitted Via Wawf (wide Area Work Flow). enter In Wawf As Follows: "ship To" N50286 "inspect By" N39040 "accept By" N39040 and Email Notification Field: Port_ptnh_wawf_notification@navy.mil no Material Is To Be Shipped Prior To The Receipt Of Acceptance. date Of First Submission=asreq block 4 - Paragraphs 10.2.2, 10.2.3, 10.2.4, And 10.3 Of Di-misc-80678 Do Not Apply. block 12 - Certification Data Must Be Submitted To Portsmouth Naval Shipyard For Review And Acceptance Prior To Each Shipment Of Material. Certification Documentation Must Be Submitted Via Wawf (wide Area Work Flow). enter In Wawf As Follows: "ship To" N50286 "inspect By" N39040 "accept By" N39040 and Email Notification Field: Port_ptnh_wawf_notification@navy.mil no Material Is To Be Shipped Prior To The Receipt Of Acceptance.
Closing Date7 Jan 2025
Tender AmountRefer Documents 

DEPT OF THE NAVY USA Tender

Machinery and Tools
United States
The Southwest Regional Maintenance Center (swrmc) Is Hereby Re-issuing Request For Proposal (rfp) No. N5523624r0003 As Rfp No. N5523625r0004 For The Execution Of The Service Craft Overhaul (sco) Requirements On The Arco (ardm-5) Class Medium Auxiliary Repair Dry Dock. Subject Requirement Was Synopsized Under Rfp No. N5523624r0003. Upon Completion Of This Sco Availability, The Dry Dock Shall Be Capable Of Carrying Out Its Respective Mission With The Expectation Of Maintaining A Satisfactory Condition Of Readiness Until The Next Sco Availability. The Sco On The Arco (ardm-5) Class Medium Auxiliary Repair Dry Dock Is Anticipated To Take Approximately Six (6) Months Beginning In May 2025 Through October 2025. The Sco Shall Be Performed Pier Side At Naval Submarine Base Point Loma. The Government Anticipates Awarding This Effort As A Supply Contract Whereas The Supply Equates To The Procurement Of A Repaired, Mission-ready Dry Dock To Be Returned To Service To The Fleet. The Anticipated Scope Of Work Includes All Labor, Supervision, Production, Testing And Quality Assurance Necessary To Prepare For And Accomplish This Sco. This Sco Shall Require A Highly Capable Contractor That Possesses A Current Agreement For Boat Repair (abr) And Must Have The Human Resources Capable Of Completing, Coordinating And Integrating Multiple Areas Of Maintenance, Repair And Modernization. All West Coast Area Sources Who Currently Hold An Abr Under Dfars Subpart 217.71, Or Are Qualified For And Willing To Enter An Agreement, Shall Be Considered By This Agency. Firms Which Do Not Possess An Abr Are Ineligible For Award Unless Adequate Time Exists To Permit The Navy To Perform An Assessment Of The Abr Application Without Impacting The Vessels Availability Dates. The Successful Offeror Will Be Required To Have A Swrmc Approved Quality System (iaw Navsea Standard Item 009-004), Approved And In Place At Time Of Contract Award. This Posting Does Not Include All Relevant Rfp Section J Attachments. Potential Offerors Will Need To Request Access To The Attachment J-1 (specification Package Sssd 501-25), Attachment J-2 (pricing Workbook), And Attachment J-3 (milestones/key Events), By Providing A Written Request To The Contract Specialist, Natalie Arenz, At Natalie.m.arenz.civ@us.navy.mil, Contracts Specialist Alondra Moreno At Alondra.moreno3.civ@us.navy.mil And The Contracting Officer, Kristin Porter, At Kristin.n.porter2.civ@us.navy.mil. Include Your Companies Sam Unique Entity Identifier (uei) Number With The Request So That Contractor Status Can Be Confirmed In The System For Award Management. These Attachments Will Be Transmitted Via Dod Safe Or Email. In Addition, There Are References On Cd-rom That Contain Limiting Distribution Statements And Will Be Disseminated By The Swrmc Contract Specialists. Please Send Requests For The Cd-rom With References To The Assigned Contract Specialists. The Government Anticipates Making One Award On Or Around February 28, 2025.
Closing Date7 Jan 2025
Tender AmountRefer Documents 

DEPT OF THE NAVY USA Tender

Civil And Construction...+2Consultancy Services, Civil And Architectural Services
United States
Indefinite-delivery/indefinite Quantity (idiq) Multiple Award Construction Contract (macc) Bahrain
Closing Date7 Jan 2025
Tender AmountRefer Documents 

DEPT OF THE NAVY USA Tender

Machinery and Tools
United States
This Is A Combined Synopsis/solicitation For Commercial Items Prepared In Accordance With The Format In Federal Acquisition Regulation (far) Subpart 12.6, "streamlined Procedures For Evaluation And Solicitation For Commercial Products And Commercial Services," As Supplemented With Additional Information Included In This Notice. This Announcement Constitutes The Only Solicitation; Quotations Are Being Requested, And A Written Solicitation Document Will Not Be Issued. this Solicitation Is A Request For Quotations (rfq). The Solicitation Document And Incorporated Provisions And Clauses Are Those In Effect Through Federal Acquisition Circular (fac) 2024-03 effective: 23 February 2024 the Associated North American Industrial Classification System (naics) Code For This Procurement Is 334516. the Associated Federal Supply Code (fsc) / Product Service Code (psc) Procurement Is 6640. the Naval Research Laboratory (nrl), Located In Washington D.c. Is Seeking To Purchase Ftir Accessories. _x__ See Attached Schedule Of Supplies/services Or _____ See Chart Below ______ See Specification Attachment supplies: Brand Name Or Equal. items Must Be Brand Name Or Equal In Accordance With Far 52.211-6. far 52.212-1 Has Been Tailored To Include The Following Additional Instructions: • This Procurement Is For New Equipment Only, Unless Otherwise Specifically Stated. No Remanufactured Or "gray Market" Items Are Acceptable. All Equipment Must Be Covered By The Manufacturer's Warranty. • Vendor Shall Be An Original Equipment Manufacturer (oem), An Oem Authorized Dealer, An Authorized Distributor, Or An Authorized Reseller For The Proposed Equipment/system Such That Oem Warranty And Service Are Provided And Maintained By The Oem. All Software Licensing, Warranty, And Service Associated With The Equipment/system Shall Be In Accordance With The Oem Terms And Conditions • Offerors Are Required To Submit Documentation From The Manufacturer Stating That They Are An Authorized Distributor For The Specific Items Being Procured. delivery Address: X U.s. Naval Research Laboratory 4555 Overlook Avenue, S.w. bldg. 49 – Shipping/receiving code 3400 washington, Dc 20375 U.s. Naval Research Laboratory 7 Grace Hopper Avenue, bldg. 702 monterey, Ca 93943-5502 U.s. Naval Research Laboratory 7 Grace Hopper Avenue, Stop 2 bldg. 704 monterey, Ca 93943-5502 Us Naval Research Laboratory stennis Space Center bldg. 2406, Code 7035.2 stennis Space Ctr., Ms 39529-5004 **fob Destination Is The Preferred Method** the Following Far & Dfars Provisions And Clauses As Identified Below Are Hereby Incorporated. Any Far & Dfars Provisions Or Clauses Not Applicable By Their Terms Shall Be Self-deleting. Any Far Or Dfars Provisions Or Clause(s) Erroneously, Or Otherwise, Omitted, That Which Should Have Been Included By Their Terms, Shall Be Considered To Be Incorporated Into This Solicitation And Any Resultant Contract. the Full Text Of Far & Dfars Provisions And Clauses May Be Accessed Electronically At https://www.acquisition.gov. The Clauses And Provisions Identified Below Are To Be Considered The Most Up-to-date Version, As Accessible At Https://www.acquisition.gov/. 52.203-11, Certification & Disclosure Regarding Payments To Influence Certain Federal Transactions 52.203-18, Prohibition On Contracting With Entities That Require Certain Internal Confidentiality Agreements Or Statements—representation 52.203-19, Prohibition On Requiring Certain Internal Confidentiality Agreements Or Statements 52.204-7, System For Award Management 52.204-16, Commercial And Government Entity Code Reporting 52.204-17, Ownership Or Control Of Offeror 52.204-20, Predecessor Of Offeror 52.204-24, Representation Regarding Certain Telecommunications And Video Surveillance Services Or Equipment – Attached Below To Be Completed And Returned With Quote/proposal. 52.204-26, Covered Telecommunication Equipment Or Services - Representation 52.209-11, Representation By Corporations Regarding Delinquent Tax Liability Or A Felony Conviction Under Any Federal Law 52.211-14, Notice Of Priority Rating For National Defense, Emergency Preparedness, And Energy Program Use 52.212-1, Instructions To Offerors-commercial Products And Commercial Services 52.212-3, Offerors Representations And Certifications-commercial Products And Commercial Services 52.217-5, Evaluation Of Options 52.219-1, Small Business Program Representations 52.223-22, Public Disclosure Of Greenhouse Gas Emissions And Reduction Goals—representation 52.225-18, Place Of Manufacture 52.225-25, Prohibition On Contracting With Entities Engaging In Certain Activities Or Transactions Relating To Iran—representation And Certifications 52.237-1, Site Visit 52.252-1, Solicitation Provisions Incorporated By Reference nrl Also Includes The Following Provisions That Must Be Completed And Returned By The Offeror: 1. Far 52.209-2, Prohibition On Contracting With Inverted Domestic Corporations- Representation. 2. Far 52.222-22, Previous Contracts And Compliance Reports 3. Far 52.222-25, Affirmative Action Compliance offerors Must Complete Annual Representations And Certifications On-line At Https://www.sam.gov/ In Accordance With Far 52.212-3, Offerors Representations And Certifications-commercial Products And Commercial Services. If Paragraph (j) Of The Provision Is Applicable, A Written Submission Is Required. the Following Contract Far Clauses Apply To This Acquisition, Unless Not Applicable By Their Terms, In Which Case Shall Be Considered Self-deleting. Any Far Clause Erroneously, Or Otherwise, Omitted, That Which Should Have Been Included By Their Terms, Shall Be Considered To Be Incorporated Into This Solicitation And Any Resultant Contract: 52.212-4, Contract Terms And Conditions-commercial Products And Commercial Services 52.203-3, Gratuities 52.203-12, Limitation Of Payments To Influence Certain Federal Transactions 52.204-9, Personal Identity Verification Of Contractor Personnel 52.204-10, Reporting Executive Compensation And First-tier Subcontract Awards 52.204-18, Commercial And Government Entity Code Maintenance 52.204-19, Incorporation By Reference Of Representations And Certifications 52.204-21, Basic Safeguarding Of Covered Contractor Information Systems 52.209-10, Prohibition On Contracting With Inverted Domestic Corporations 52.219-8, Option To Extend Services 52.217-9, Option To Extend The Term Of The Contract 52.219-28, Post-award Small Business Program Rerepresentation 52.232-1, Payments 52.232-8, Discounts For Prompt Payment 52.232-11, Extras 52.232-23, Assignment Of Claims 52.232-39, Unenforceability Of Unauthorized Obligations 52.232-40, Providing Accelerated Payments To Small Business Subcontractors 52.233-1, Disputes 52.233-3, Protest After Award 52.233-4, Applicable Law For Breach Of Contract Claim 52.243-1, Changes-fixed-price 52.247-34, F.o.b Destination 52.249-1, Termination For Convenience Of The Government (fixed Price)(short Form) 52.249-4, Termination For Convenience Of The Government (services)(short Form) 52.252-2, Clauses Incorporated By Reference 2. Far 52.212-5, Contract Terms And Conditions Required To Implement Statutes Or Executive Orders – Commercial Products And Commercial Services the Following Subparagraphs Of Far 52.212-5 Are Applicable, Unless Otherwise Not Applicable By Their Terms, In Which Case Shall Be Considered Self-deleting: 52.204-10 52.209-6 52.219-6 52.222-3 52.222-19 52.222-21 52.222-26 52.222-36 52.222-50 52.223-18 52.225-13 52.232-33 3. Dfars 212.301 - Solicitation Provisions And Contract Clauses For The Acquisition Of Commercial Products And Commercial Services Dod Class Deviation 2018-o0021, Commercial Item Omnibus Clause For Acquisitions Using The Standard Procurement System, Issued October 1, 2018 (revised October 1, 2018): Dod Class Deviation 2018-o0021 the Following Solicitation Dfars Provisions Apply To This Acquisition, Unless Not Applicable By Their Terms, In Which Case Shall Be Considered Self-deleting. Any Dfars Provisions Erroneously, Or Otherwise, Omitted, That Which Should Have Been Included By Their Terms, Shall Be Considered To Be Incorporated Into This Solicitation: 252.203-7005, Representation Relating To Compensation Of Former Dod Officials 252.204-7008, Compliance With Safeguarding Covered Defense Information Controls 252.204-7016, Covered Defense Telecommunications Equipment Or Services – Representation 252.204-7017, Prohibition On The Acquisition Of Covered Defense Telecommunications Equipment Or Services—representation 252.215-7007, Notice Of Intent To Resolicit the Following Solicitation Dfars Clauses Apply To This Acquisition, Unless Not Applicable By Their Terms, In Which Case Shall Be Considered Self-deleting. Any Dfars Clause Erroneously, Or Otherwise, Omitted, That Which Should Have Been Included By Their Terms, Shall Be Considered To Be Incorporated Into This Solicitation And Any Resultant Contract: 252.203-7000, Requirements Relating To Compensation Of Former Dod Officials 252.203-7002, Requirement To Inform Employees Of Whistleblower Rights 252.204-7003, Control Of Government Personnel Work Product 252.204-7009, Limitations On The Use Or Disclosure Of Third-party Contractor 252.204-7012, Safeguarding Covered Defense Information And Cyber Incident Reporting 252.204-7015, Notice Of Authorized Disclosure Of Information For Litigation Support 252.204-7018, Prohibition On The Acquisition Of Covered Defense Telecommunications Equipment Or Services 252.211-7003, Item Unique Identification And Valuation 252.211-7008, Use Of Government-assigned Serial Numbers 252.223-7008, Prohibition Of Hexavalent Chromium 252.225-7013, Duty-free Entry 252.227-7015, Technical Data - Commercial Products And Commercial Services 252.227-7037, Validation Of Restrictive Markings On Technical Data 252.232-7003, Electronic Submission Of Payment Requests And Receiving Reports 252.232-7006, Wide Area Workflow Payment Instructions 252.232-7010, Levies On Contract Payments 252.239-7010, Cloud Computing Services 252.239-7018, Supply Chain Risk 252.244-7000, Subcontracts For Commercial Products Or Commercial Services 252.246-7003, Notification Of Potential Safety Issues 252.246-7004, Safety Of Facilities, Infrastructure, And Equipment For Military Operations submission Instructions: all Quoters Shall Submit 1 (one) Copy Of Their Technical And Price Quote. include Your Company’s Unique Entity Id And Cage Code/n Cage Code On Your Quote. please Reference This Combined Synopsis/solicitation Number: N00173-25-q-1301212503 On Your Correspondence And In The "subject" Line Of Your Email. the Technical And Price Quotation Shall Be Submitted Via Email To: government Point Of Contact purchasing Agent Name: Ashley Grimes tel: (202)-875-9579 email: Ashley.n.grimes6.civ@us.navy.mil questions Concerning The Rfq: All Questions Concerning This Rfq Are Due Via Email To The Purchasing Agent’s Email Address Above No Later Than (nlt) 10 Business Days After The Sending Of This Request For Quotation (rfq) To Ensure Timely Award. The Government May, In Its Sole Discretion, Choose Not To Respond To Questions Received After The Deadline. the Government Intends To Award A Purchase Order As A Result Of This Combined Synopsis/solicitation That Will Include The Terms And Conditions Set Forth Herein. Award May Be Made Without Discussions Or Negotiations; Therefore, Prospective Contractors Shall Have An Active Registration In The System For Award Management (sam) Database (www.sam.gov) In Accordance With Federal Acquisition Regulation (far) Part 4.1102 And Part 52.204-7 When Submitting A Response To This Solicitation. the Government Will Award A Contract Resulting From This Solicitation To The Responsible Offeror Whose Offer Conforming To The Solicitation Will Be Most Advantageous To The Government, Price And Other Factors Considered. The Following Factors Shall Be Used To Evaluate Offers: lowest Price Technically Acceptable - Offers Will Be Ranked Lowest To Highest According To Price. A Price Analysis Will Be Conducted To Determine Whether The Lowest Price Will Result From A Single Award Or Multiple Awards. Based On The Price Analysis, The Lowest Price Offer Or Multiple Offers, Will Be Forwarded To The Requiring Activity For Technical Evaluation (offer(s), In Accordance With The Specifications, Will Be Deemed Either Technically Acceptable Or Technically Unacceptable). If The Lowest Price Offer Or Offers Is Found Technically Acceptable And The Pricing Determined Fair And Reasonable By The Contracting Officer, Evaluation Will Be Deemed Complete And Award Will Be Made Based On The Lowest Price Offer(s). If The Lowest Price Offer Is Determined Technically Unacceptable, Another Analysis Will Be Conducted Amongst The Remaining Offers To Determine If A Single Or Multiple Awards Will Provide The Lowest Price. The Lowest Price Offer(s) Will Be Sent For Technical Evaluation. This Process Is Repeated In Order Of Price Until An Offer Or Combination Of Offers Is Deemed Technically Acceptable And Price Is Determined Fair And Reasonable. options. When Applicable, The Government Will Evaluate Offers For Award Purposes By Adding The Total Price For All Options To The Total Price For The Basic Requirement. The Government May Determine That An Offer Is Unacceptable If The Option Prices Are Significantly Unbalanced. Evaluation Of Options Shall Not Obligate The Government To Exercise The Option(s). terms And Conditions. To Facilitate The Award Process, All Quotes Must Include A Statement Regarding The Terms And Conditions Herein As Follows: "the Terms And Conditions In The Solicitation Are Acceptable To Be Included In The Award Document Without Modification, Deletion, Or Addition." or "the Terms And Conditions In The Solicitation Are Acceptable To Be Included In The Award Document With The Exception, Deletion, Or Addition Of The Following:" exceptions. Quoter Shall List Exception(s) And Rationale For The Exception(s). late Submissions Shall Be Treated In Accordance With The Solicitation Provision At Far 52.212-1(f). Emailed Submissions Are Accepted And Are The Preferred Form Of Submission. Receipt Will Be Verified By The Date/time Stamp On Email. quotation Contents quotations Shall Comply With Or Clearly State, At A Minimum, The Following Information: (1) Open Market Or Gsa Federal Supply Schedule (fss) Pricing. Quotations Should State “open Market” Or Should Reference The Applicable Gsa/fss Number. (2) Expiration Date Of Quoted And Submitted Prices. (3) Contractor’s Federal Tax I.d., Cage Code, And Duns Number. (4) Payment Terms Will Be Net 30 Unless Stated Differently On The Quote. (5) If Available, Please Include Your Company’s Current Published Price List. (6) Include Shipping And Handling If Applicable.
Closing Date7 Jan 2025
Tender AmountRefer Documents 

DEPT OF THE NAVY USA Tender

Others
Corrigendum : Closing Date Modified
United States
Nsn 7r-1560-014467869-gf, Tdp Ver 005, Qty 21 Ea, Delivery Fob Origin. All Contractual Documents (i.e. Contracts, Purchase Orders, Task Orders, Delivery Orders And Modifications) Related To The Instant Procurement Are Considered To Be "issued" By The Government When Copies Are Either Deposited In The Mail, Transmitted By Facsimile, Or Sent By Other Electronic Commerce Methods, Such As Email. The Government's Acceptance Of The Contractor's Proposal Constitutes Bilateral Agreement To "issue" Contractual Documents As Detailed Herein. Early And Incremental Deliveries Accepted. Interested Parties May Obtain Copies Of Military And Federal Specificationsand Standards, Qualified Products Lists (qpls), Qualified Product Databases(qpds), Military Handbooks, And Other Standardized Documents From The Dodsingle Stock Point (dodssp) At Document Automation And Production Service(daps) In Philadelphia, Pa. Note: Patterns, Drawings, Deviation Lists, Purchase Descriptions, Etc. Are Not Stocked At Dodssp. Most Documents Are Available In Adobe Pdf Format From Assist-online At: Http://quicksearch.dla.mil/. Users May Use Assist-quick Search To Search For And Download Available Documents Directly Using Standard Browser Software. Documents That Are Not Available For Downloading From Assist-quick Search Can Be Ordered From The Dodssp Website Using The Assist Shopping Wizard After Obtaining A Dodssp Customer Account By Following The Registration Procedures. Users Who Do Not Have Access To The Internet May Contact The Dodssp Assisthelp Desk At 215-697-2667 Or 215-697-2179 (dsn: 442-2667), Or Mail Their Request To Dladocument Services, Bldg. 4/d, 700 Robbins Avenue, Philadelphia Pa 19111-5094. The Proposed Contract Action Is For Supplies Or Services For Which The Government Intends To Solicit And Negotiate With Only One Source Under The Authority Of Far 6.302-1. All Responsible Sources May Identify Their Interest And Capability To Respond To The Requirement Or Submit Proposals, Quotationsor Capability Statements. This Notice Of Intent Is Not A Request Forcompetitive Proposals. However, All Proposals Received Within 45 Days (30days If Award Is Issued Under An Existing Basic Ordering Agreement (boa) Afterdate Of Publication Of This Synopsis Will Be Considered By The Government. A Determination By The Government Not To Compete With This Proposed Contract Based Upon Responses To This Notice Is Solely Within The Discretion Of The Government. Information Received Will Normally Be Considered Solely For The Purpose Of Determining Whether To Conduct A Competitive Procurement. Based Upon Market Research, The Government Is Not Using The Policies Contained In Far Part 12, Acquisition Of Commercial Items, In Its Solicitation For The Described Supplies Or Services. However, Interested Persons May Identify Tothe Contracting Officer Their Interest And Capability To Satisfy Thegovernment's Requirement With A Commercial Item Within 15 Days Of This Notice.
Closing Date7 Jan 2025
Tender AmountRefer Documents 

DEPT OF THE NAVY USA Tender

Others...+2Electrical Goods and Equipments, Electrical and Electronics
Corrigendum : Closing Date Modified
United States
Nsn 7r-1680-015628732-e7, Ref Nr 123av50587-301, Qty 1 Ea, Delivery Fob Origin. The Proposed Contract Action Is For The Requirement Of The Following Item Which The Government Intends To Solicit And Negotiate With Only One Source Under The Authority Of Far 6.302-1. Niin: 015628732 Nomen: Drawer,power Dist,a P/n: 123av50587-301 Qty: 1 Responsible Sources May Identify Their Interest And Capability To Respond To The Requirement Or Submit Proposals, Quotations Or Capability Statements. This Notice Of Intent Is Not A Request For Competitive Proposals. However, All Proposals Received Within 45 Days (30 Days If Award Is Issued Under An Existing Basic Ordering Agreement (boa) After Date Of Publication Of This Synopsis Will Be Considered By The Government. A Determination By The Government Not To Compete With This Proposed Contract Based Upon Responses To This Notice Is Solely Within The Discretion Of The Government.information Received Will Normally Be Considered Solely For The Purpose Of Determining Whether To Conduct A Competitive Procurement.
Closing Date6 Jan 2025
Tender AmountRefer Documents 

DEPT OF THE NAVY USA Tender

Chemical Products
United States
Item Unique Identification And Valuation (jan 2023)|19|||||||||||||||||||| Higher-level Contract Quality Requirement (navicp Review Feb 1991)(feb 1999)|1|mil-i-45208 Or Iso 9001 Ansi/ncsl Z540.3 Or Iso 10012 | Inspection Of Supplies--fixed-price (aug 1996)|2||| Navy Use Of Abilityone Support Contractor - Release Of Offeror Information (3-18))|1|wss-n00104| First Article Approval--contractor Testing (sep 1989)|10| Fat Requirements Are Included In The Drawings||15|180|n64498|tbd|tbd|45||| Notice Of Total Small Business Set-aside (oct 2020)(deviation 2020-o0008)|1|| Alternate A, Annual Representations And Certifications (oct 2024)|13|x|x||x|||||||||| Annual Representations And Certifications (may 2024)|13|336612|1000|x|x|x||||||||| Notice Of Priority Rating For National Defense, Emergency Perpardeness, And Enrgy Progam Use (april 2008))|2||x| Evaluation Of First Article Testing|3|||x| Any Order Resulting From This Solicitation Will Be Issued Bi-laterally Requiring The Contractor's Written Acceptance Prior To Execution. _______________ - Place Of Material Inspection _______________ - Place Of Packaging Inspection & Final Acceptance Requested Delivery Is 300 Days After Date Of Contract. Quoted Delivery Is____ Days Adc. Dfars 252.232-7006, Wide Area Workflow Payment Instructions, Is Incorporated By Reference Into This Request For Quotation(rfq). Any Resulting Order Will Require Electronic Submittal Of Invoices And Receiving Reports Through Piee-wawf, And Will Include The Clause In Full Text, Complete With Submittal Instructions. Far Clause 52.213-4, Terms And Conditions-simplified Acquisitions (other Than Commercial Products And Commercial Services), Is Incorporated By Reference Into This Rfq.this Clause Is A Compilation Of The Most Commonly Used Clauses That Apply To Simplified Acquisitions And Incorporates Them By Reference As Well. All Contractual Documents (i.e. Contracts, Purchase Orders, Task Orders, Delivery Orders And Modifications) Related To The Instant Procurement Are Considered To Be "issued" By The Government When Copies Are Either Deposited In The Mail, Transmitted By Facsimile, Or Sent By Other Electronic Commerce Methods Such As Email. The Government's Acceptance Of The Contractor's Proposal Constitutes Bilateral Agreement To "issue" Contractual Documents As Detailed Herein. Dd1423 Contract Data Items Apply To This Procuremment. Contractor First Article Test And Contractor Production Lot Test Are Required To Be Completed And And Approved By N64498 Prior To Starting Production. \ 1. Scope 1.1 ;this Procurement Specification Contains The Requirements For Manufacture And The Contract Quality Requirements For ;an/bra-24 Antenna Seal Assembly; For Use On Navy Submarines.; 2. Applicable Documents 2.1 Applicable Documents - The Document(s) Listed Below Form A Part Of This Contract/purchase Order Including Modifications Or Exclusions. 2.1.1 Documents, Drawings, And Publications Supplied Are Listed Under "drawing Number". These Items Should Be Retained Until An Award Is Made. 2.1.2 "document References" Listed Below Must Be Obtained By The Contractor. Ordering Information Is Included As An Attachment To This Contract/purchase Order. 2.1.3 The "document Changes" Section Provides Supersessions/changes To Referenced Documents. 2.2 Order Of Precedence - In The Event Of A Conflict Between The Text Of This Contract/purchase Order And The References And/or Drawings Cited Herein, The Text Of This Contract/purchase Order Shall Take Precedence. Nothing In This Contract/purchase Order, However, Shall Supersede Applicable Laws And Regulations Unless A Specific Exemption Has Been Obtained. Drawing Data=psnsy-0063-12 |80064| -|lr |d|0001 | -|49998|0103349 Drawing Data=re-b102146 |80064| E| |d|0001 | E|49998|0073812 Drawing Data=re-b102147 |50225| D| |d|0001 | D|49998|0046933 Drawing Data=re-b102148 |50225| D| |d|0001 | D|49998|0047618 Drawing Data=re-b102150 |50225| F| |d|0001 | F|49998|0050965 Drawing Data=re-b102151 |50225| F| |d|0001 | F|49998|0049220 Drawing Data=re-b102225 |50225| E| |d|0001 | E|49998|0050481 Drawing Data=re-b102226 |50225| C| |d|0001 | C|49998|0026072 Drawing Data=re-b102227 |50225| E| |d|0001 | E|49998|0043319 Drawing Data=re-b102260 |80064| H| |d|0001 | H|49998|0178831 Drawing Data=re-b102270 |50225| F| |d|0001 | F|49998|0043237 Drawing Data=re-c102149 |50225| G| |d|0001 | G|49998|0060273 Drawing Data=re-c102184 |50225| E| |d|0001 | E|49998|0035246 Drawing Data=re-c49491 |80064| H| |d|0001 | H|49998|0091687 Drawing Data=re-c49502 |80064| H| |d|0001 | H|49998|0125769 Drawing Data=re-d102152 |80064| E| |d|0001 | E|49998|0085710 Drawing Data=4677518 |80064| J| |d|0001 | J|49998|0184705 Drawing Data=4677518 |80064| J| |d|0002 | J|49998|0086018 Document Ref Data=fed-std-h28 |0020| |b |941221|a| |01| Document Ref Data=mil-std-130 | | |n |121116|d| |01| Document Ref Data=mil-std-973 | | | |950113|a| |03| Document Ref Data=qq-n-281d | | | |851023|a|2 | | Document Ref Data=asme B46.1 | | | |190101|a| | | Document Ref Data=iso9001 | | | |150915|a| | | Document Ref Data=sae As9390 | | |d |190401|a| | | Document Ref Data=iso10012 | | | |030415|d| | | Document Ref Data=mil-i-45208 | | |a |810724|a|1 | | Document Ref Data=ncsl Z540.3 | | | |060803|a| | | Document Ref Data=sae-ams-qq-s-763 | | |d |150301|a| | | Document Ref Data=astm B21/b21m | | | |200401|a| | | Document Ref Data=ethacure 300 Coml | | | | |a| | | Document Ref Data=adiprene L167 (90-95a) Coml | | | | |a| | | 3. Requirements 3.1 ;design And Manufacturing - The ;an/bra-24 Antenna Seal Assembly; Furnished Under This Contract/purchase Order Shall Meet The Material, Physical, Mechanical And Test Requirements As Specified On Drawings Re-c49502 (consisting Of Item Numbers 1 Thru 4) Including Associated Specifications Mentioned In This Procurement.; 3.1.1 ;the Supplier Shall Have Or Fabricate The Required Tooling To Perform The Acceptance Test Specified On Drawing Re-c49502.; 3.1.2 ;source Control Drawing Re-b102260 - The Urethane Elastomer (adiprene L167) And Curative (ethacure 300) Shall Only Be Procured For Lanxess Urethane Systems; And Shall Conform To The Requirements Specified On Drawing Re-b102260, Dash No.2. ; 3.2 ;marking Requirements - The Supplier Shall Permanetly Mark And Identify Each First Article And Production Lot Unit ;an/bra-24 Seal Assembly; In Accordance With The Requirements Of Drawing Re-c49502, Note 2 (contract Number, Vendor Part Number And Serial Number) Per Mil-std-130.; 3.2.1 ;the Supplier Shall Permanently Mark Parts Re-b102147, Re-b102148, Re-b102150, Re-b102151 And Re-c102149 As Identified On The Applicable Drawing Per Mil-std-130. The Supplier Shall Mark ;tag Or Bag; Each Part With Contract, Heat, Lot And Serial Number Per Mil-std-130 Until Installed On The Designed Assembly.; 3.2.2 ;the Supplier Shall Mark ;tagor Bag; Parts Re-b102146, Re-b102148/item No.2, Re-b102225 And Re-c49491 With Contract, Applicable Part, Heat, Lot Or Batch And Serial Number Per Mil-std-130 Until Installed On The Designated Assembly.; 3.3 ;first Article Testing/inspection - (supplier Testing/inspection). The First Article Testing/inspection Procedure And Approval Are Required For The ;an/bra-24 Seal Assembly;. Government Approval Is Required Prior To Commencement Of First Article Unit.; 3.4 ;notification - The Supplier Shall Notify Naval Surface Warfare Center, Philadelphia Division, (nswcpd) 5001 S. Broad Street, Philadelphia, Pa 19112- 1403 By Emial Matthew.j.ogilvie.civ@us.mavy.mil, Code 242mo After Award Of Contract.; 3.4.1 ;the Nswcpd Is The Acceptance Activity For The Contract Data Requirements List (dd1423) Data Items. Nswcpd Wawf/irapt ;acceptor; Dodacc Is ;n64498;.; 3.5 Configuration Control - Mil-std-973 Entitled "configuration Management", Paragraph 5.4.8, Configuration Control (short Form Procedure), Is Hereby Incorporated. The Contractor Shall Submit All Engineering Change Proposals In Accordance With Mil-std-973, Paragraph 5.4.8.2 And Appendix D. Requests For Deviations Shall Be Processed In Accordance With Mil-std-973, Paragraph 5.4.8.3 And Appendix E. Requests For Waivers Shall Be Processed In Accordance With Mil-std-973, Paragraph 5.4.8.4 And Appendix E. (original And Two Copies Shall Be Submitted To Contracting Officer, Navicp-mech, P. O. Box 2020, Mechanicsburg Pa. 17055-0788.) 3.5.1 Configuration Control - When The Contractor Has Received Authorization On A Prior Contract For The Same Nsn For The Use Of A Drawing Of A Later Revision Status, That Authorization Is Hereby Extended To All Succeeding Contracts/purchase Orders Until Another Drawing Revision Is Approved. The Contractor Will Notify The Pco Of This Occurrence In Each Instance, In The Response To The Solicitation. Such Notification Shall Be In Writing Setting Forth The Contract Under Which The Prior Authorization Was Granted, The Date Of The Granting Of The Authorization, And The Name Of The Granting Authority. Contractors Shall Also Refer Technical Inquiries (other Than Those Covered By Mil-std-973) On Company Letterhead Signed By A Responsible Company Official, With Copies Distributed As Stated Below. The Original And Two Copies Of All Contractor Generated Correspondence Regarding Configuration Shall Be Submitted To Contracting Officer, Navicp-mech, P.o. Box 2020, Mechanicsburg, Pa 17055-0788. Contractors Are Cautioned That Implementing Engineering Changes, Waivers, Deviations Or Technical Inquiries Into The Contract/purchase Order Without Approval Of The Contracting Officer Will Be At The Sole Risk Of The Contractor. 3.6 Mercury Free - The Material Supplied Under This Contract/purchase Order Is Intended For Use On Submarines/surface Ships And Therefore Shall Contain No Metallic Mercury And Shall Be Free From Mercury Contamination. Mercury Contamination Of The Material Will Be Cause For Rejection. If The Inclusion Of Metallic Mercury Is Required As A Functional Part Of The Material Furnished Under This Contract, The Contractor Shall Obtain Written Approval From The Procurement Contracting Officer Before Proceeding With Manufacture. The Contractor's Request Shall Explain In Detail The Requirements For Mercury, Identify Specifically The Parts To Contain Mercury, And Explain The Method Of Protection Against Mercury Escape. Such A Request Will Be Forwarded Directly To The Procurement Contracting Officer With A Copy To The Applicable Government Inspector. Upon Approval By The Contracting Officer, The Vendor Will Provide A "warning Plate" Stating That Metallic Mercury Is A Functional Part Of The Item And Will Include Name And Location Of That Part. The Use Of Mercury, Mercury Compounds, Or Mercury-bearing Instruments And/or Equipment In A Manner Which Might Cause Contamination In The Manufacture, Assembly, Or Test Of Material On This Contract Is Prohibited. The Most Probable Causes Of Contamination Are Direct-connected Manometers, Mercury Vacuum Pumps, Mercury Seals, Or The Handling Of Mercury In The Immediate Vicinity. Mercury Switches, Mercury In Glass Thermometers, Standard Cells And Other Items Containing Mercury May Be Used If They Are Located So As Not To Constitute A Contamination Hazard. If External Contamination By Metallic Mercury Occurs Or Is Suspected, The Following Test May Be Used To Determine Whether Contamination By Metallic Mercury Exists Or Whether Corrective Cleaning Measures Have Been Effective. Enclose The Equipment In A Polyethylene Bag Or Close-fitting Airtight Container For Eight Hours At Room Temperature (70 Degrees F Minimum).sample The Trapped Air And If Mercury Vapor Concentration Is 0.01 Mg/cu Meter Or More, The Material Is Mercury Contaminated Insofar As The Requirements Of This Contract Are Concerned. These Requirements Shall Be Included In Any Subcontract Or Purchase Order Hereunder And The Contractor Shall Insure Subcontractor Compliance With These Requirements. Technical Questions Pertaining To These Requirements Shall Be Referred To The Procurement Contracting Officer Via The Cognizant Administrative Contracting Officer. For Background, The Following Information Is Provided: Mercury Is Corrosive To Gold, Silver, Nickel, Stainless Steels, Aluminum And Copper Alloys. Stainless Steels, Nickel, And Copper Alloys Are Widely Used In Reactor Plants And Other Submarine/surface Ship Systems. Accidental Trapping Of Mercury In A Component Could Cause Serious Damage To Vital Parts. Mercury Is Also Toxic If Inhaled, Ingested, Or Absorbed Through The Skin. It Is Evident That Grave Consequences Could Result From Small Amounts Of Mercury Vapor Present In An Unreplenished Submarine/surface Ship Atmosphere. 4. Quality Assurance 4.1 Responsibility For Inspection - Unless Otherwise Specified In The Contract/purchase Order, The Contractor Is Responsible For The Performance Of All Inspection Requirements As Specified Herein. Except As Otherwise Specified In The Contract/purchase Order, The Contractor May Use His Own Or Any Other Facilities Suitable For The Performance Of The Inspection Requirements Specified Herein, Unless Disapproved By The Government. The Government Reserves The Right To Perform Any Of The Inspections Set Forth In The Specification Where Such Inspections Are Deemed Necessary To Assure Supplies And Services Conform To Prescribed Requirements. 4.2 Responsibility For Compliance - All Items Must Meet All Requirements Of This Contract/purchase Order. The Inspection Set Forth In This Specification Shall Become A Part Of The Contractor's Overall Inspection System Or Quality Program. The Absence Of Any Inspection Requirements Shall Not Relieve The Contractor Of The Responsibility Of Assuring That All Products Or Supplies Submitted To The Government For Acceptance Comply With All Requirements Of The Contract/purchase Order. Sampling In Quality Conformance Does Not Authorize Submission Of Known Defective Material, Either Indicated Or Actual, Not Does It Commit The Government To Acceptance Of Defective Material. 4.3 Records - Records Of All Inspection Work By The Contractor Shall Be Kept Complete And Available To The Government During The Performance Of Contract/purchase Order And For A Period Of 365 Calendar Days After Final Delivery Of Supplies. 4.4 ;inspection System - The Supplier's Quality Inspection System Shall Be In Accordance With Mil-i-45208 Or Iso 9001 And Ncsl Z540.3 Or Iso 10012. The Supplier Shall Develop And Submit Their Written Quality Inspection And Test Plan As Indicated On The Contract Data Requirements List (dd Form 1423). Government Approval Of The Supplier's Written Quality Inspection And Test Plan Is Required By The Contract. Cdrl: Quality Inspection & Test Plan Per Mil-i-45208, Ncsl Z540.3 And Di-qcic-81110; 4.5 ;surface Roughness - All Surface Finishes Are In Rms Measurements. Where The Degree Of Surface Roughness Is Indicated, The Surface Shall Be Free From All Visible Imperfections As Defined By Standard Asme B46.1. ; 4.6 ;finished Edges - Finished Edges Shall Be In Accordance With The Applicable Drawing Requirements.; 4.7 ;threads - Threads Shall Be Inspected In Accordance With Fed-std-h28/20 System 21 Requirements. Thread Inspection Shall Include The Measurement And Recording Of The Major Diameter For External Threads And The Minor Diameter For Internal Threads.; 4.8 ;material Control - The Supplier Shall Have An Effective Material Control System That Provides For Certified Quantitative Mill Or Industrial Laboratory Reports Of Chemical And Physical Analysis By Heat, Lot Or Batch For Raw Material Ordered For First Article And Production Units. If The Material Is Subsequently Heat-treated A Certification Of Physical Analysis, After Heat Treatment Is Also Required For Each Heat Lot Or Batch. Also, Where The Applicable Material Specification Calls Out (e.g. Corrosion Resistance Test, Macro-etch Test) These Test Results Shall Also Be Reported On The Applicable Mill Or Industrial Laboratory Report. (1) The Physical Analysis Shall Establish The Following Properties For Metallic Parts: Ultimate Tensile Strength, Yield Strength And Elongation. (2) The Physical Analysis Shall Establish The Properties For Non-metallic Parts: Re-b102260/dash No.2 As Specified On The Drawing.; 4.9 ;first Article Testing/inspection - (supplier Testing/inspection). The Supplier Shall Perform First Article Testing/inspection On ;an/bra-24 Seal Assembly; In Accordance With The Applicable Drawings And Their Approved First Article Procedure.; 4.9.1 ;the First Article Inspection Shall Be Made By The Cognizant Dcma-qar At The Supplier's And/or Subcontractor Facility. The Supplier Shall Notify Nswcpd, Code 242mo Two Weeks In Advance Prior To The Scheduled First Article Testing/ Inspection, So An Nswcpd Representative Has The Option Of Being Present During The First Article Testing/inspection.; 4.10 ;first Article Approval For Testing/inspection Procedure And Acceptance - (supplier Testing/inspection). The Supplier Shall Prepare And Submit Their First Article Testing/inspection Procedure ;an/bra-24 Seal Assembly; In Accordance With The Requriements Of Di-ndti-80603 And Applicable Drawings As Indicated On The Contract Data Requirements List (dd Form 1423). Government Approval Of The Procedure Is Required Prior To Commencement Of First Article Unit. Cdrl: First Article Testing/inspection Procedure Per Di-ndti-80603a; 4.11 ;first Article Testing/inspection.; 4.11.1 ;visual/dimensional Inspection - The Supplier Shall Visually And Physically Inspect 100% The First Article Unit (component Parts/assembly) And Record The Actual Measurements Of Each Dimension And Threads (including Of The Major Diameter For External Threads And The Minor Diameter For Internal Threads) Identified On The Applicable Drawings Including The Results Of The Adjustment Performed Of The Assembly Per Drawing Re-c49502. Threads Shall Be Inspected 100% And Results Recorded.; 4.11.2 ;acceptance Test - The Supplieer Shall Perform Acceptance Inspection And Test On The Assembly Re-c49502 In Accordance With Drawing Requirements And Record The Actual Results. Failure To Meet The Drawing Acceptance Test Notes A And I Will Be Cause For Rejection Of The Assembly.; 4.12 ;first Article Testing/inspection Report And Acceptance - (supplier Testing/ Inspection). The Supplier Shall Submit For The First Article Unit ;an/bra-24 Seal Assembly; Testing/inspection Reports In Compliance With The Requirements Of Di-ndti-80603 And Applicable Drawings. The Report Shall Also Include A Copy Of ;certified Mill Certification; Certified Industrial Laboratory Analysis; Certificate Of Compliance And Visual/dimensional Inspection Report; Identified In The Objective Quality Evidence Records Section Of This Document, And As Indicated Ont He Contract Data Requirements List (dd Form 1423). Government Approval Of The First Article Testing/inspection Report Is Required Prior To Commencement Of Production Units. Cdrl: First Article Testing/inspection Report Per Di-ndti-80809b; 4.13 ;production Lot.; 4.13.1 ;visual/dimensional Inspection - The Supplier Shall Visually And Physically Inspect 100% Each The Production Lot Unit (component Parts/assemblies) And Record The Actual Measurements Of Each Dimension And Threads (including Of The Major Diameter For External Threads And The Minor Diameter For Internal Threads) Identified On The Applicable Drawings Including The Results Of The Adjustment Performed On Each Assembly Per Drawing Re-c49502. Threads Shall Be Inspected 100% And Results Recorded.; 4.13.2 ;acceptance Test - The Supplier Shall Perform Acceptance Inspection And Test On Each Assembly Re-c49502 In Accordance With Drawing Requirements And Record The Actual Results. Failure To Meet The Drawing Acceptance Test Notes A And I Will Be Cause For Rejection Of The Assembly.; 4.14 ;production Lot Testing/inspection Report And Acceptance - (supplier Testing/ Inspection). The Supplier Shall Submit For The Completed Production Units ;an/bra-24 Seal Assembly; Testing/inspection Reports In Compliance With The Applicable Data Item Descriptions (dids) And Drawings. The Production Lot Testing/inspection Report Shall Consist Of ;certified Mill Certification; Certified Industrial Laboratory Analysis; Certificate Of Compliance; Visual/ Dimensional Inspection Report And Mercury Exclusion Certification; Identified In The Objective Quality Evidence Records Section Of This Document, And As Indicated On The Production Lot Test/inspection (plt) Contract Data Requirements List (dd Form 1423). Government Approval Of The Procduction Lot Testing/inspection Report Is Required Prior To Shipment Of Production Lot Units. Cdrl: Production Lot Testing/inspection Report Per Di-ndti-80809b; 4.15 ;production Lot Inspection/acceptance - (supplier Testing/inspection). The Supplier Shall Submit For The Production Lot Units, The Inspection And Test Reports Identified In The Objective Quality Evidence Records Section Of This Document And As Indicated On The Production Lot Testing/inspection (plt) Contract Data Requirements List (dd Form 1423). Government Approval Is Required Prior To Shipment Of Production Units.; 4.16 ;final Inspection And Acceptance - Final Inspection And Acceptance Of Production Lots Shall Be Made By The Cognizant Dcma-qar In Conjuction With The Specific Government Inspection Instructions (sgiis) Furnished By Nswcpd. In Addition To The Normal Dcma Surveillance, The Production Unit(s) Shall Be Under The Surveillance Of Nswcpd Quality Assurance Specialist As Required.; 4.17 ;objective Quality Evidence Records - The Supplier Shall Maintain Objective Quality Evidence Data (oqeds) Of Raw Material And Finished Parts Of ;an/bra-24 Seal Assembly;. Records Shall Be Traceable By Drawing/item, Heat Lot Or Batch, Serial And Contract Number. All Oqeds Shall Be Clearly Legible Including Name And Title. The Supplier May Provide Exact (quality) Photocopies Of Objective Quality Evidence Records Being Delivered Under This Purchase Order Instead Of Originals.; 4.17.1 ;the Supplier Shall Furnish A Copy Of The Following Oqeds Listed Below And As Indicated On The Contract Data Requirements List (dd Form 1423) For Acceptance. The Reports Shall Be Correlated To The Drawing/item, Heat, Lot Or Batch, Serial, Contract And Assembly Number. Supplier Format Is Acceptable For The Below Listed Cdrls. A. Certified Quantitative Mill Or Industrial Laboratory Certification (chemical And Physical Analysis) For Drawing Numbers Re-b102147, Re-b102150, Re-b102151, Re-b102225 And Re-c102149. Cdrl: Certified Mill Certificate Per Di-misc-80678 B. Certified Industrial Laboratory Analysis Shall Establish The Properties For Material Urethane Elastomer Adiprene L167 (90-95a) As Specified On Drawing Re-b102260, Dash No. 2. Cdrl: Certified Industrial Lab Analysis Per Di-misc-80678 C. Certificate Of Compliance For: (1) Drawing Re-b102148/item No.2 (certifying Part In Accordance With The Applicable Drawing And Material Specification Requirements). (2) Drawing Re-b102260 (certifying Curative Ethacure 300 In Accordance With Drawing Requirements). (3) Drawings Re-d102152, Re-b102226, Re-c102184, Re-b102227, Re-b102270 And 4677518/item No. 42 Tooling Use For Acceptance Test (certifying Tooling Material And Fabrication In Accordance With The Applicable Material Specification And Drawing Requirements). Cdrl: Certificate Of Compliance Per Di-misc-80678 D. Visual/dimensional Inspection Reports Shall Show All The Characteristics, The Actual Measurement Results Of Each Dimension And Feature Inspected (componenet Parts/assemblies) Including Threads (also The Major Diameter For External Threads And The Minor Diameter For Internal Threads), Assembly Re-c49502 Acceptance Inspection And Test Results, Adjustment Of The Assembly, Contract Number, Name Of Supplier, Drawing/item Number, Drawing Revision Letter, Heat, Lot Or Batch, Serial Of Finished Parts, Assembly Serial Number, Item Nomenclature, Inspector's Acceptance Signature And Date. Cdrl: Visual/dimensional Inspection Report Per Di-ndti-80809b E. Mercury Exclusion Certification (representing The Contract Units Shipment) Cdrl Mercury Exclusion Certification Per Di-misc-80678; 5. Packaging 5.1 Preservation, Packaging, Packing And Marking - Preservation, Packaging, Packing And Marking Shall Be In Accordance With The Contract/purchase Order Schedule And As Specified Below. Mil-std 2073 Packaging Applies As Found Elsewhere In The Schedule 6. Notes 6.1 Ordering Information For Document References - The Department Of Defense Single Stock Point (dodssp), Website Http://www.dsp.dla.mil/, Provides Product Information For The Department Of Defense Index Of Specifications And Standards (dodiss) (i.e.military/federal Specifications And Standards), Data Item Descriptions (dids), And Other Dodssp Products. A. Availability Of Cancelled Documents - The Dodssp Offers Cancelled Documents That Are Required By Private Industry In Fulfillment Of Contractual Obligations In Paper Format. Documents Can Be Requested By Phoning The Subscription Services Desk. B. Commercial Specifications, Standards, And Descriptions - These Specifications, Standards And Descriptions Are Not Available From Government Sources. They May Be Obtained From The Publishers Of The Applicable Societies. C. Ordnance Standards (os), Weapons Specifications (ws), And Navord Ostd 600 Pages - These Type Publications May Be Obtained By Submitting A Request To: Commander, Indian Head Division, Naval Surface Warfare Center Code 8410p, 101 Strauss Avenue Indian Head, Md 20640-5035 D. On Post-award Actions, Requests For "official Use Only" And "noforn" (not Releasable To Foreign Nationals) Documents Must Identify The Government Contract Number, And Must Be Submitted Via The Cognizant Defense Contract Management Command (dcmc) For Certification Of Need For The Document. On Pre-award Actions Such Requests Must Be Submitted To The Pco For Certification Of Need For The Document. E. Noforn Military Specifications And Standards (including Amendments, Change Notices And Supplements, But Not Interim Changes) To Be Ordered From: Contracting Officer Navicp-mech Code 87321 5450 Carlisle Pike P.o. Box 2020 Mechanicsburg, Pa. 17055-0788 F. Nuclear Reactor Publications Assigned Navsea Documents And Identification Numbers (i.e. Navsea Welding Standard, Navsea 250-1500-1) Are To Be Ordered From: Commanding Officer Navicp-mech Code 009 5450 Carlisle Pike P.o. Box 2020 Mechanicsburg, Pa. 17055-0788 G. Technical Manuals Assigned Navsea Identification Numbers (i.e. Navsea Welding And Brazing Procedure, Navsea S9074-aq-gib-010/248) Are To Be Ordered From: Naval Inventory Control Point Code 1 Support Branch 700 Robbins Avenue Phildelphia, Pa. 19111-5094 H. Interim Changes And Classified Specifications Shall Be Obtained By Submitting A Request On Dd Form 1425 To Navicp-mech. Date Of First Submission=asreq ;;approval Of The Quality Inspection Plan By Nswc Philadelphia Division Is Required Prior To First Article.;; ;;nswcpd Is The Acceptance Activity For Cdrl Data Item A001. Nswcpd Wawf/irapt Acceptor Dodacc Is "n64498".;; Date Of First Submission=asreq ;;procedure Shall Be In Accordance With The Requirements Of The Applicable Drawings.;; ;;approval Of Teh Procedure By Nswc Philadelphia Division Is Required Prior To Commencement Of First Article Unit.;; ;;nswcpd Is The Acceptance Activity For Cdrl Data Item A002. Nswcpd Wawf/irapt Acceptor Dodacc Is "n64498".;; Date Of First Submission=asreq ;;approval Of The Report By Nswc Philadelphia Division Is Required Prior To Commencement Of Production Lot Units.;; ;;nswcpd Is The Acceptance Activity For Cdrl Data Item A003. Nswcpd Wawf/irapt Acceptor Dodacc Is "n64498".;; Date Of First Submission=asreq ;;supplier Format Is Acceptable.;; ;;plt Report Shall Consist Of Oqed Records Listed In Contract Section E: Certified Mill Certification; Certified Industrial Lab Analysis; Certificate Of Compliance; Visual/dimensional Inspection Report And Mercury Exclusion Certification.;; ;;approval Of The Report By Nswc Philadelphia Division Is Required Prior To Shipment Of Production Lot Units.;; ;;nswcpd Is The Acceptance Activity For Cdrl Data Item A004. Nswcpd Wawf/irapt Acceptor Dodacc Is "n64498".;;
Closing Date6 Jan 2025
Tender AmountRefer Documents 

DEPT OF THE NAVY USA Tender

Others
United States
Contact Information|4|n793.12|n00383|215-697-2995|jessica.l.harpel2.civ@us.navy.mil| item Unique Identification And Valuation (jan 2023)|19|||||||||||||||||||| higher-level Contract Quality Requirement|8|x|||||||| inspection And Acceptance Of Supplies|26||||||||||||||||||||||||||| wide Area Workflow Payment Instructions (jan 2023)|16|invoice And Receiving Reports (combo)||n/a|n00383|n/a|n/a|n/a|n/a||||||||| navy Use Of Abilityone Support Contractor - Release Of Offeror Information (3-18))|1|| equal Opportunity (sep 2016)|2||| warranty Of Supplies Of A Noncomplex Nature (jun 2003)|6|1 Year After Date Of Delivery |45 Days After Discovery Of Defect||||| equal Opportuity For Workers With Disabilities (jun 2020)|2||| buy American-free Trade Agreements-balance Of Payments Program-basic (feb 2024)|11|||||||||||| limitations On Pass-through Charges (jun 2020)|1|| alternate A, Annual Representations And Certifications (oct 2024)|13|||||||||||||| buy American-free Trade Agreements-balance Of Payments Program Certificate-basic (feb 2024))|5|||||| buy American--balance Of Payments Program (feb 2024)|1|| royalty Information (apr 1984)|1|| annual Representations And Certifications (may 2024)|12|336413|1250||||||||||| facsimile Proposals (oct 1997)|1|| notice Of Priority Rating For National Defense, Emergency Preparedness, Andenergy Program Use (apr 2008))|2||x| the Buno Number Associated For This Requirement Is 166915. this Requirement Is Aog And Needs To Be Expedited As Soon As Possible. \ 1. Scope 1.1 . Markings Shall Be In Accordance With Mil-std-130. 2. Applicable Documents - Not Applicable 3. Requirements - Not Applicable 4. Quality Assurance Provisions - Not Applicable. 5. Packaging- Mil-std 2073 Packaging Applies As Found Elsewhere In The Schedule 6. Notes - Not Applicable
Closing Date6 Jan 2025
Tender AmountRefer Documents 

DEPT OF THE NAVY USA Tender

Others
United States
16--seat,aircraft, In Repair/modification Of
Closing Date6 Jan 2025
Tender AmountRefer Documents 
371-380 of 429 archived Tenders