Computer Tenders
Computer Tenders
Scientific and Academic Computer Network State Research Institute Tender
Furnitures and Fixtures
Poland
Purchaser Name: Scientific and Academic Computer Network State Research Institute | Announcement of the Procurement of the Service "Provision of Permanent and Ad hoc Protection Services for Facilities Located in Warsaw"
Closing Date7 Feb 2025
Tender AmountRefer Documents
Presidency of the Municipal Computer Center of Malaga Tender
Consultancy Services
Corrigendum : Tender Amount Updated
Spain
Purchaser Name: Presidency of the Municipal Computer Center of Malaga | Systems Administration and Infrastructure, Communications and Product Management Service from the manufacturer Microfocus for the Economic and Social Council (ces)
Closing Date5 Feb 2025
Tender AmountEUR 23.9 K (USD 24.8 K)
Scientific and Academic Computer Network State Research Institute Tender
Software and IT Solutions
Poland
Purchaser Name: Scientific and Academic Computer Network State Research Institute | Purchase of Recertification of the Quality Management System for Registration and Maintenance of .pl Domain Names for Compliance with the PN-EN ISO 9001:2015 Standard
Closing Date7 Feb 2025
Tender AmountRefer Documents
DEPT OF THE ARMY USA Tender
Others
United States
Details: The Medical Readiness Contracting Office West (mrco) Is Issuing This Sources Sought Notice To Find Potential Sources To Provide A Cost-per-test (cpt) Agreement Or Reagent Rental Agreement To Include Reagents, Molecular Pcr Instrument/equipment, Consumables, Maintenance Support And Instrument Warranties To Conduct Molecular Genetic And Infectious Disease Testing For The Brooke Army Medical Center (bamc) Department Of Pathology And Area Laboratory Services – Molecular Laboratory, Fort Sam Houston, Texas. A Base Period Of Performance From 01 October 2025 Through 30 September 2030 Will Be Required For This Action.
this Is Not A Solicitation Announcement – This Is A Sources Sought Notice And Is Issued Solely For Information And Planning Purposes – It Does Not Constitute A Request For Quote (rfq) Or A Promise To Issue An Rfq In The Future. Solicitations Are Not Available At This Time And Requests For A Solicitation Will Not Receive A Response. This Notice Does Not Constitute A Commitment By The United States Government To Contract For Any Supply Or Service Whatsoever. All Information Submitted In Response To This Announcement Is Voluntary; The United States Government Will Not Pay For Information Requested Nor Will It Compensate Any Respondent For Any Cost Incurred In Developing Information Provided To The United States Government. Not Responding To This Sources Sought Notice Does Not Preclude Participation In Any Future Rfq, Should One Be Issued. It Is The Responsibility Of The Potential Offerors To Monitor This Site For Additional Information Pertaining To This Requirement.
the Government Will Use Responses To This Notice In Formulating Its Acquisition Strategy. If The Government Does Not Receive Sufficient Information In Response To This Notice To Verify The Potential For Competition Exists, It Is Possible That A Sole-source Contract, Supported By A Justification And Approval Document, Will Be Issued To Support The Government's Requirement. Mrco-w Is Seeking The Following Information (please Answer Paragraph Below With Your Response):
company Name, Cage Code, And Point Of Contact Information (including Phone Number And Email Address), And Socio-economic Category(ies) As Related To Naics 325413 (in-vitro Diagnostic Substance Manufacturing), Such As 8(a), Hubzone, Women-owned, Service-disabled Veteran-owned, Small, Or Other-than-small.
capability Statement (limited To Ten Pages), Describing How Your Company Meets The Below Objectives, Providing Additional Proof (such As Fda Approval) Where Appropriate:
our Customer, The Department Of Pathology, Molecular Laboratory At Bamc Requires The Following Instrument/equipment, Reagents, Supplies, And Service:
requirements Of Services To Be Provided:
basic Requirements: Molecular Pcr Testing Equipment, Reagents, Consumables, Maintenance Support And
instrument Warranties Used In Support Of Detection Of The Test Menu Below. The System(s) Must Fit As A Table-top Accessed Set And Cannot Be “stand Alone”.
test Menu And Special Requirements For Awarded Contractor: Listed Testing Requirements Must Be Capable Of Completion In Under 4.5 Hours From Start Time. Proposal Should Include Automated Molecular Processing For:
hla-dq2/hla Dq8 (gluten-sensitive Enteropathy/celiac Disease)
all Relevant Alleles
apolipoprotein E (apoe/alzheimer’s Disease)
gene Variants 2, 3, And 4
haemochromatosis (hfe Gene)
h63d, C282y, S65c, And E168x
*dermatomycoses Testing Must Be Performed As A Panel To Include Testing For At Least 80% Of The Following Dermatophytes, Yeasts, And Molds:
trichophyton Equinum
trichophyton Tonsurans
trichophyton Interdigitale
trichophyton Mentagrophytes
t. Interdigitale /mentagrophytes
trichophyton Quinckeanum
trichophyton Schoenleinii
trichophyton Simii
t. Quinckeanum /schoenleinii /simii
trichophyton Benhamiae (white Fr.)
trichophyton Benhamiae (yellow)
t. Bullosum /benhamiae (afr.)
t. Concentricum /erinaceid
trichophyton Erinaceid
t. Verrucosum /eriotrephon
trichophyton Rubrum
trichophyton Violaceum
epidermophyton Floccosum
nannizzia Fulva
nannizzia Gypsea
nannizzia Incurvate
nannizzia Persicolor
microsporum Canis
microsporum Ferrugineum
microsporum Audouinii
m. Canis /audouinii
candida Parapsilosis
candida Guilliermondii
candida Albicans
fusarium Solani
fusarium Oxysporum
scopulariopsis Brevicaulis
method Performance/comparison Shall Be At The Expense Of The Vendor, Shall Include Linearity Material And Reagents, And Be Consistent With Current Clsi Standards And Related Documents, Cap Standards And Federal Regulations, For The Following:
correlation Studies For Each Analyte. A Minimum Of 20 Samples, Spanning The Reportable Range, Shall Be Run By The Present And The New Contracted Method. Vendor Shall Analyze Numbers And Provide Statistical Data To Accept The New Method. Statistics Shall Consist Of At Least Mean, Bias, Slope, Y-intercept, Correlation Coefficient, And Meet Current Standards Defined By Clsi.
linearity Analysis Shall Be Performed On New Contracted Instrument(s) For Each Analyte To Determine Reportable Range With Data Reduction In Accordance With Clsi Guidelines.
precision Study Shall Be Performed Utilizing Normal And Abnormal Control Material. This Should Consist Of A Within Run Precision Study Of 10 Normal And 10 Abnormal Controls And A Day-to-day Precision Study Of Normal And Abnormal Controls.
sensitivity: Sensitivity May Be Validated Concurrently With The Linearity Verifications.
specificity Studies: Adverse Effects For Increased Bilirubin, Hemolysis, Lipemia, Or Other Interrupting Substances Including Blood Container Are Evaluated For Interfering Substances For Each Method Performed.
reference Range: Determine A Reference Range For Each Test Following Clsi Guideline C-23a. Samples Used For The Reference Range Study Must Be Representative Of The Patient Population Being Tested. Reference Range Assessment Must Be Performed For Each Lab. One Of The Following Protocols Should Be Used:
if The Suggested Manufacturer's Range Is Not Appropriate For The Patient Population, A Reference Range Must Be Established And May Require Additional Reference Individuals.
if A Laboratory Is Currently Using The Proposed Instrument/reagent System, The "in-use" Reference Range Can Be Transferred To The "new" System If A Method Comparison Study Between The Two Systems Proves To Be Acceptable. If Comparison Studies Are Not Acceptable, Then An Alternate Test Must Be Provided.
analytical Measurement Range Validation Studies Must Be Performed By Vendor For Applicable Analytes,
all Technical Procedures Must Be Provided Electronically By Vendor In Clsi Format, Using Software Compatible With Each Laboratory's Computer System, For Local Modification (editable) To Meet Cap Requirements.
carryover Studies Must Be Performed, As Applicable, As Part Of The Initial Evaluation Of The Instrument. Vendor Shall Provide Interpretation Of Raw Data For Each Instrument Installed And Validate No Carryover Exists Within The Test Platforms.
vendor Must Provide All Reagents, Calibrators, And Controls Needed Along With Technical Assistance To Perform Correlation Studies From A Single Lot At No Additional Cost For New Test Methods Or Changes In Test Menus. (i.e., Vendor Is To Provide All Manpower And Reagents/supplies To Do Correlation Studies).
vendor Must Provide Hands-on Training To Staff Onsite Prior To Or During Instrument Integration At The Facility. Expert/advanced User Training Should Be Offered At Vendor/manufacturer Site At A Minimum Of Two (2) Staff Per Instrument.
analytical Systems:
ability To Manage Testing Workflow Of Hospital Laboratory. Instruments Must Be Able To Perform Testing For All Described Testing Requirements Simultaneously.
analyzer(s) Must Be Capable Of Completing Hybridization In One Hour Or Less And Resulting A Sample In Under 4.5 Hours (from Time Of Dna Isolation).
integrated Modules (if Applicable) Must Only Require One System Control Center (computer And Screen) To Simplify Operations.
instruments Must Have Load On The Fly Capabilities For Reagents, Samples, Bulk Solutions, And Consumables. Quantity Of Consumables And Reagents Must Be Monitored By The System Software.
analyzers Must Either Utilize Disposable Pipette Tips Or Demonstrate Clinically Insignificant Carryover.
vendor Must Have Commonality Across All Analyzer Platforms For The Following:
software
reagents
consumables
methodology
analyzers Must Feature Error-proof Reagent And Commodity Design With Built In Safeguards To Prevent Reagent Mix-ups, Probe Crashes And Unnecessary Downtime.
calibration Of Analyzer(s) Must Be Easy And Of Minimal Frequency. Calibrations Must Only Be Required When Qc Is Out Of Range Or New Lot Numbers Of Reagent Are Put Into Use. Calibrators Should Be Liquid And Ready To Use With No Reconstitution Or Prep Required Prior To Use. List Any Calibrators That Require Preparation And The Required Process.
analyzers Must Be Capable Of Determining The Quality Of The Sample, And Be Able To Detect Clots, Low Or Insufficient Volumes, Aspiration Issues Such As Bubbles, And Other Applicable Liquid Level Sensing Capabilities. Please Describe How Analyzer Detects.
quality Control Frequency Not To Exceed Once/24 Hours/instrument Platform.
chosen Analyzer(s) Must Have Minimal Daily, Weekly, And Monthly Maintenance Downtime. Please Provide Total Maintenance Times, Including Washes And Wait Time, For Daily, Weekly, And Monthly Maintenance. Please Include Any Hands On, Automated Non-maintenance Activities.
vendor To Provide Average Number Of Service Calls Per Year Per Analyzer, Provide Access To A 24/7 On-call Support System, And Perform Preventive Maintenance As Required.
analyzer Must Accommodate Multiple Tube Sizes/vial Sizes Simultaneously.
vendor Must Provide Btu Output For Both Analytics And Automation Systems.
meet Space Limitations. Selected Design Must Maintain Walkways And Clearances Around Track And Instruments.
lis Connectivity Must Be Supported/available And Should Have Approved Use For Windows 10 Or Greater (more Recent).
reagents And Supplies:
vendor Must Describe Kit Size Options Available For Applicable Tests.
vendor Reagents Should Be 99% Liquid Ready To Use From Storage, Requiring No Reconstitution Or Mixing. List All Reagents That Are Not Liquid, Ready To Use For Consideration.
vendor Calibrators Must Be At Least 95% Liquid Ready To Use From Storage, Requiring No Reconstitution Or Mixing. List All Assay Calibrators That Are Not Liquid, Ready To Use For Consideration.
quality Of Reagents, Supplies And Disposables: The Contractor Shall Assure That All Supplies Provided/ordered For Use On Their Equipment Will Be Of The Quality Necessary To Produce A Quality Product. The Reagent Quality Must Be High Enough To Satisfy Proficiency Testing Standards Of The College Of American Pathologists (cap) And The Joint Commission. In The Event That Supplies Are Found To Be Defective And Unsuitable For Use With The Contractor's Equipment Or The Contractor Has Failed To Comply With The Requirements Herein, The Contractor Is Required To Deliver The Supplies Within 24 Hours Of Receipt Of The Verbal Order.
vendor Must Provide 5 Years Of Fda Field Action Notifications.
Closing Date20 Jan 2025
Tender AmountRefer Documents
Scientific and Academic Computer Network State Research Institute Tender
Services
Others
Poland
Purchaser Name: Scientific and Academic Computer Network State Research Institute | Poland – Medical Practice Services – Świadczenie Usług Medycznych Z Zakresu Medycyny Pracy Oraz Dodatkowej Opieki Medycznej Dla Pracowników Nask-pib W Ramach Miesięcznych Abonamentów
Closing Date24 Jan 2025
Tender AmountRefer Documents
Scientific and Academic Computer Network State Research Institute Tender
Services
Software and IT Solutions
Poland
Purchaser Name: Scientific and Academic Computer Network State Research Institute | Poland – Software Programming And Consultancy Services – Usługi Konsultacyjno-doradcze It W Zakresie Wdrożenia Platformy Openstack
Closing Date24 Jan 2025
Tender AmountRefer Documents
National Academy For Computer Training And Research nactar Tender
Works
Electrical Goods and Equipments...+1Electrical and Electronics
Bangladesh
Purchaser Name: National Academy For Computer Training And Research nactar | Supply & Installation Of Split Type Air Cooler At Nactar, Bogura.
Closing Date15 Jan 2025
Tender AmountRefer Documents
7201-7210 of 7457 archived Tenders