- Home/
- Philippines/
- Caraga Regional Hospital/
- Overview
Caraga Regional Hospital Tender
Caraga Regional Hospital Tender
Costs
Summary
Supply And Delivery Of Various Equipment For Calibration Services - Rebid , Hospital / Medical Equipment ,caraga Regional Hospital
Description
Description Republic Of The Philippines Department Of Health Caraga Regional Hospital Surigao City Bids And Awards Committee Ooooooo --------------------------------------------------------------------------------------------------------------- @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ Invitation To Bid Ib No. 2024-01-21 (115) Supply And Delivery Of Various Equipment For Calibration Services - Rebid Abc: ₱ 4,800,000.00 ========================================================= 1. The Caraga Regional Hospital (crh), Through The Fy2024 Internally Generated Fund (igf) Intends To Apply The Sum Of Being The Approved Budget For The Contract (abc) Of Four Million Eight Hundred Thousand Pesos Only ( Php 4,800,000.00 ) Under The Contract For The Supply And Delivery Of Various Equipment For Calibration Services - Rebid. Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening And Items Below Are Subject For A Competitive Bidding, To Wit: Line Item Code Description Qty Unit Of Measure Unit Cost Total Cost 1 Defibrilator Measurement Analyzer 1 Unit 1,600,000.00 1,600,000.00 2 Electrosurgical Devices Analyzer 1 Unit 1,700,000.00 1,700,000.00 3 6 In 1 Patient Vital Signs Simulation/nibp, Spo2, Ecg, Temp, Ibp & Respiration Functionality Test 1 Unit 1,000,000.00 1,000,000.00 4 Gas Flow Equipment Analyzer 1 Unit 500,000.00 500,000.00 Grand Total ₱ 4,800,000.00 1. Defibrilator Measurement Analyzer Description Patient Category Defibrillators Analyzer Automates The Inspection And Preventive Maintenance Testing Of Defibrillators. They Need To Be Able To Test At Least Four Basic Defibrillator Performance Characteristics: Discharge Energy, Synchronized-mode Operation, Automated External Defibrillation, And Ecg Monitoring. Purpose Of Use Clinical Or Other Purpose Calibration Of Your Measuring Instruments Has Two Objectives. It Checks The Accuracy Of The Instrument And It Determines The Traceability Of The Measurement. In Practice, Calibration Also Includes Repair Of The Device If It Is Out Of Calibration. Clinical Department /ward Biomedical Department Technical Specifications Defib Measurement; Load Resistance; 45 -50ω +/- 1% No-inductive Range: 0-200 Joules Accuracy: ±1% Of Reading ±1 Joule Range (high): 200-600 Joules Accuracy: ±1% Of Reading ± 1 Joule Resolution: 0 - 0.1 Joule Voltage: 0 – 1000 To 5000 Volts Current: 0 – 50 To 100 Amps Sampling Rate: 200-250 Khz Sampling Frequency Maximum Pulse Width (capture Time): 5us – 100 To 120 Ms Clock Accuracy; 0.10s To 100+/_ 0.05s Aed Pulse Mode Waveforms; Normal Sinus Rhythm (nsr): 20 -300 Bpm, Amplitude 1.00mv (± 2%) Asystole (asys) Ventricular Fibrillation - Coarse (vfbc) 230-240 Bpm Amplitude) 1.00mv (± 2%) Ventricular Fibrillation – Fine (vfbf) 230-240 Bpm Amplitude) 1.00mv (± 2%) Monomorphic Ventricular Tachycardia(mvt0: 210 Bpm, 1.00mv (±2%) 200-210 Bpm, 1.00mv (±2% Atrial Fibrillation (afb): 20-300 Bpm, Amplitude 1.00mv (± 2%) Ecg Simulator: Ecg Simulation With High Level Output. Ecg Waveforms – Sinus: Normal Sinus Rhythm (nsr): 20 – 300 Bpm, Amplitude 0.50 – 5.00mv (± 2%) St Elevation (ste): 20 -300 Bpm, Amplitude 0.50 – 5.00mv (± 2%) St Depression (std): 20 -300 Bpm, Amplitude 0.50 – 5.00 Mv (±2%) Myocardial Infarction (mi): 20 – 300 Bpm, Amplitude 0.50 – 5.00mv (±2%) Tall T (tt): 20 300 Bpm, Amplitude 0.50 -5.00mv (±2%) Ecg Waveforms – Ventricular Arrhythmias: Premature Ventricular Contraction: 75-80 Bpm Intermittent (pvci): Amplitude 0.50 -5.00 – 5.00 Mv (±2%) Bigeminy (big): 75-80 Bpm, Amplitude 0.50 – 5.00mv (± 2%) Trigeminy (trig): 75-80 Bpm, Amplitude 0.50 – 5.00mv (± 2%) Ventricular Flutter (vflt): 230-240 Bpm, Amplitude 0.50 -5.00mv (± 2%)) Ventricular Fibrillation – Coarse (vfbc); 23-=240 Bpm, Amplitude 0.50 -5.00mv) Ventricular Fibrillation – Fine (vfbf): 230-240 Bpm, Amplitude 0.50 – 5.00mv (± 2%)) Monomorphic Ventricular Tachycardia (mvt): 200-210 Amplitude 0.50 – 5.00mv (±2% Right-focal Premature Ventricular Contraction (rfpvc) : 70-80 Bpm, Amplitude 0.50 -5.00mv (±2%)) Ecg Waveforms – Atrial Conduction Arrhymias: First Degree Av Block (favb): 70-80 Bpm, Amplitude 0.50 – 5.00mv (± 2%) Second Degree Av Block : 70-80 Bpm - Mobitz I (sav_ Mi): Amplitude 0.50 -5.00 Mv (± 2%) Second Degree Av Block: 70-80 Bpm) - Mobitz Ii (savb_mii): Amplitude 0.50 -5.00mv (±2%) Third Degree Av Block (tavb): 45-50 Bpm, Amplitude 0.50 -5.00mv (±2%)) Ecg Waveforms – Atrial Arrhythmias: Sinus Arrhythmias (sar): 20 -300 Bpm, Amplitude 0.50 -5.00 Mv (±2%) Missing Beat (mb): 20 - 300 Bpm, Amplitude 0.50 -5.00mv (±2%) Atrial Flutter (aflt): 250-300 Bpm, Amplitude 0.50 -5.00 Mv (±2%) Atrial Fibrillation (afb); 20 - 300 Bpm, Amplitude 0.50 -5.00 Mv (±2%) Paroxysmal Atrial Tachycardia (pat): 170-180 Bpm, Amplitude 0.50 -5.00mv (±2%) Premature Junctional Contraction (pjc): 20 - 300 Bpm, Amplitude 0.50 -5.00mv (±2%) Ecg Pacer Waveforms: Synchronous Atrial (aai): 20 - 300 Bpm, Pulse Amplitude 0.50 5.00mv Pulse Width 0.1 – 2.0ms Asynchronous Astrial (aoo): 20 - 300bpm Pulse Amplitude 0.50 – 5.00mv Pulse Width 0.1 - 2.0ms Pacer (pcr); 20 – 300 Bpm Pulse Amplitude 0.50 – 5.00mv. Pulse Width 0.1 – 2.0ms Ventricular Pacer (vvi); 20 300 Bpm Pulse Amplitude 0.50 – 5.00mv Pulse Width 0.1 – 2.0ms Atrial & Ventricular Pacer (ddd): 20 - 300 Bpm Pulse Amplitude 0.50 – 5.00mv Pulse Width 0.1 – 2.0ms R-wave Detection (rwd): 20 -300 Bpm Pulse Amplitude 0.50 -5.00mv Ecg Performance Wave Forms: Sine (sine): 0.1 – 300hz 1.00 – 10.00 Mv Square (sq): 0.1 – 300hz 1.00 – 10.00 Mv Triangle (tri): 0.1 – 300hz 1.00 – 10.00 Mv Sawtooth (saw): 0.1 – 300hz 1.00 – 10.00 Mv Inverse Sawtooth (invsaw): 0.1 – 300hz 1.00 – 10.00 Mv Pulse (pulse): 0.1 – 300hz 0.50 – 5.00 Mv Ecg Noise Selection: Amplitude 0 – 10.00mv Frequency 50 - 60 Hz Ecg Accuracy: Rate: ± 1% Bpm Amplitude: ± 2% (la-ll). ± 10% (paddles) Lead Ii: 1 – 10 Mv (in Steps Of 0.5 Mv). Other Leads Are Proportional To Lead Ii By The Following Percentages; Lead I: 60% Lead Ii 100% Lead Iii: 40% Pacer Input: Fix Load: 40-50ω Accuracy: 1 % , Non-inductive Over Voltage Protection: 5000 Va (4500-5000) Variable Load: 50 -1600ω In 50ω Steps Accuracy: 1 % Non Inductive Pulse Rate: 5.0 – 800ppm Accuracy: +/- (0.5% Rdg + 0.1ppm) Heart Rate Selection: 20 - 300 Bpm Under And Overdrive: 85% (20 Bpm Min) And 115% (300bpm Max) Wave Form Selection: Nsr, Vfibc, Vfibf, Mvt, Afib, Missing Beat, R-wave Detection Pulse Current Amplitude: 5.00 – 200ma Accuracy: +/- (1% Rdg + 0.02ma) Current Measurement: Average (rms) Leading Edge, Trailing Edge, Peak ( The Highest During The Pulse ) Pulse Width: 1.00 – 100ms Accuracy: +/- (0.5% Rdg + 0.01ms) Pulse Energy: 1µj – 2.00j Accuracy: +/- 4% + 10µj Pacer Manufacturer Algorithms: Cu Medical, Ge, Hp,laerdal, Mindray, Philips, Physiocontrol, Schiller, Welchallyn, Zoll Pacer Refractory Periods: Refractory Period Test: 15 – 500ms (paced And Sensed) Accuracy; +/- 1ms Pacer Sensitivity Test: Wave Form, R Wave: Polarity Normal And Reversed Selectable Dynamic Sensitivity: 0.05mv -5.00mv In 50µv Steps Pacer Interference Test (immunity): Heart Rate: 20 -300 Bpm Frequency: 50 Or 60 Hz Noise Level In Mv: 0-15.0mv Operation: 9.2-9.6v/2300-2400mah Nickel Metal Hydride Battery Pack Battery Charge Time: 2-2.5 Hours Battery Capacity (fully Charged): 10-12 Hours Mains Supply: 110/230v Ac.: 50 To 60hz 35va Power Supply Storage Environment: - 15°c To 60°c Operating Condition: 0°c To 40°c Environment Protection: Ip 40 Communication: Usb Display: Lcd Colour Graphic Display ¼ Vga Memory: 80-100 Test Results Including Graphs) Impact Rating: 5j Technical Services As Follows: • System Warranty Must Be Five (5) Years • Calibration Of The Unit Must Be Performed After Installation With Certificate • Service Call Within 24 Hours Maximum And Must Have Repair Facility In Mindanao Area. • Preventive Maintenance For Every Quarter Until Warranty Expires. • Service Kits And Consumables To Be Included For One Year Use. • Supplier Must Deliver And Install The Unit Without Cost To The Owner Accessories, Consumables, Spare Parts, Other Components Accessories: • Aed Lead • Ecg Snap Adapter 10 Pack • Usb Cable • Test N Tag 2 Bluetooth Printer • Thermal Labels Rolls 5 Pack • Paddle Adaptor Box • Paddle Adaptor Box Lead (red) • Paddle Adaptor Box Lead (black) • Applied Part Adaptor 10 Pack • Carrying Bag • Manual Guide Training, Installation And Utilisation Pre-installation Requirements Supplier To Perform Installation, Safety And Operation Checks Before Handover. Requirements For Commissioning 1.local Clinical Staff To Affirm Completion Of Installation, 2. Calibration Certificate And Warranty Certificate 3. The Supplier Must Have A Track Record/history/experience For Having A Calibration Center Within The Philippines For Assurance Of Being A Biomedical Company. 4. The Supplier Must Have A Certificate Of Being An Authorized Service Partner. 5. The Supplier Must Have A Branch Office In The Mindanao For Technical Support Purposes. 6. The Supplier Must Have A Local Business Permit For Services In The Mindanao Area. Training Of User/s 5 Days Training And Of User Biomed Engineer & Staff In Operation, Basic Maintenance And Documentation , Shall Be Provided User Care To Demonstrate The Proper Cleaning And Disinfection With Provision Of Printed Cards Or Tags Beside The Unit. Warranty And Maintenance Warranty • 5 Years For Parts And Labor • Cleaning And Maintenance Of Machine • Shall Have Spare Parts Availability Once The End User Needs It. Environmental Factors • Capable Of Being Stored Continuously In Ambient Temperature Of 0 To 50 Deg C And Relative Humidity Of 15 To 90%. • Capable Of Operating Continuously In Ambient Temperature Of 10 To 40 Deg C And Relative Humidity Of 15 To 90% Documentation Documentation Requirements User, Technical And Maintenance Manuals To Be Supplied In English Language. Service Manual In English. List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost. Certificate Of Calibration, Warranty And Inspection To Be Provided. Safety And Standards International Standards Risk Classification - Class B (ghtf Rule 11);class Ii (usa); Class Ii (eu, Japan, Canada And Australia) International Standards - Iso 13485, Fda, Ce. Delivery Period 90 Calendar Days From Receipt Of The Notice To Proceed Terms Of Payment Upon Full Delivery, Installed, Tested And Commissioned Service Center Must Have Service Center Within Caraga Regional, Cebu City, Cdo Or Davao City Post Qualification The Bidder Is Required To Send A Demo Unit To Caraga Regional Hospital. Failure To Comply With The Preferred Schedule Of The Procuring Entity For The Post Qualification Can Be A Ground For Disqualification. (no Extensions Allowed) 2. Electrosurgical Devices Analyzer Description Patient Category Electrosurgical Unit (esu) Analyzers Automate The Testing And Inspection Of The Output Circuits And Safety Feature Of Esus. They Perform Testing That Would Otherwise Require Several Other Pieces Of Equipment, As Well As Considerably More Time And Greater Technician Expertise. Purpose Of Use Clinical Or Other Purpose Calibration Of Your Measuring Instruments Has Two Objectives. It Checks The Accuracy Of The Instrument And It Determines The Traceability Of The Measurement. In Practice, Calibration Also Includes Repair Of The Device If It Is Out Of Calibration. Clinical Department /ward Biomedical Department Technical Specifications Power Measurement: True Rms Value Of Applied Waveform Power Rating: 0 – 800w (rms) Accuracy: ± ( 1w + 5% Of Reading) Duty Cycle: 80 – 100% Up To 60 Seconds Load Bank: 0 - 5115ω Resolution: 5 -7ω Voltage (peak): 5– 10kv (peak) - Closed Load Only Accuracy: ± (10% Of Reading + 15v) Voltage: 5 – 700v Rms Accuracy: ± (10% Of Reading + 5v) Current (rms): 0 – 6000 Ma With Load Banks 0 -8000ma External Load Test Accuracy: ± (2% Of Reading + 10ma) Crest Factor: 1.4 – 20 (vpeak / V Rms) Rms Bandwidth; Instrumentation Only: 30 Hz To 10mhz (-3 Db) With Loads: 30 Hz To 2.5 Mhz (-3 Db) Variable Loads: 5 - 5115ω Steps @ 5ω (1023 Steps) Accuracy: ± (1% + 0.5, 0.0ω Of Set Of Load) Load Array: Ceramic Resistors (non-inductive) Measurement Delay: Foot Switch Delay Selectable Between 300-5000ms (8-10m Seconds Resolution) Rf Leakage (high Frequency Leakage): Active: From Active Part To Earth Passive: From Plate – Receptacle – Earth Load: Variable See Power Measurement Fixed 2 X 200ω Accuracy: ± 1%, + 0.5, - 0.0 Ω Contact Quality Monitoring (cqm): Range: 0 -475ω Steps @ 1 Ω Steps Motor Driven Potentiometer Accuracy: ± 5-7% ± 1-2ω Alarm Register: High And Low Manual Confirmation Ranging: Manual Or Automatic Output Connectors: Remote Foot Switch Control (cut): Yellow, Single Relay Contact Remote Foot Switch Control (coag): Blue, Single Relay Contact High Frequency Leakage: Through 4mm Sockets And Power Measurements Usb: Pc Download Oscilloscope Output: 0.5v/a, 100ma, Rf Current Minimum Input, Un-calibrated, Indication Only Isolation: 10kv Isolation Between Measurement Device And Enclosure Low Frequency Filter: 100hz Filter To Avoid Low-frequency Disturbance Or Interference General: Memory: 4000- 5000 Records (4mb) Output: Csv And Sss Format Dimensions: Not More Than 373mm X310mm X210mm Weight: 10-12kg / 22 Lbs Operating Temperature: 10°c - 40°c / 50°c / 32°f -122°f Main’s Power: 115/230v Ac + 10%; 48 To 66 Hz, 35 Va Fuses: 2x 1.6 A (t) Ceramic Standard Accessories: Mains Lead, Usb Lead, Calibration Certification Technical Services As Follows: • System Warranty Must Be Five (5) Years • Calibration Of The Unit Must Be Performed After Installation With Certificate • Service Call Within 24 Hours Maximum And Must Have Repair Facility In Mindanao Area. • Preventive Maintenance For Every Quarter Until Warranty Expires. • Service Kits And Consumables To Be Included For One Year Use. • Supplier Must Deliver And Install The Unit Without Cost To The Owner Accessories, Consumables, Spare Parts, Other Components Accessories: • Test Lead, Usb Lead • Cut/coag Control Interface Cables • Power Cord • Colored Sheathed Banana Set • Operator Cd • Manual • Carrying Bag Training, Installation And Utilisation Pre-installation Requirements • Supplier To Perform Installation, Safety And Operation Checks Before Handover. Requirements For Commissioning • Local Clinical Staff To Affirm Completion Of Installation, Calibration Certificate And Warranty Certificate • The Supplier Must Have A Track Record/history/experience For Having A Calibration Center Within The Philippines For Assurance Of Being A Biomedical Company. • The Supplier Must Have A Certificate Of Being An Authorized Service Partner. • The Supplier Must Have A Branch Office In The Mindanao For Technical Support Purposes. • The Supplier Must Have A Local Business Permit For Services In The Mindanao Area. Training Of User/s 5 Days Training Of User Biomed Engineer & Staff In Operation, Basic Maintenance And Documentation , Shall Be Provided User Care To Demonstrate The Proper Cleaning And Disinfection With Provision Of Printed Cards Or Tags Beside The Unit. Warranty And Maintenance Warranty • 5 Years For Parts And Labor • Cleaning And Maintenance Of Machine • Shall Have Spare Parts Availability Once The End User Needs It. Environmental Factors • Capable Of Being Stored Continuously In Ambient Temperature Of 0 To 50 Deg C And Relative Humidity Of 15 To 90%. • Capable Of Operating Continuously In Ambient Temperature Of 10 To 40 Deg C And Relative Humidity Of 15 To 90% Documentation Documentation Requirements User, Technical And Maintenance Manuals To Be Supplied In English Language. Service Manual In English. List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost. Certificate Of Calibration, Warranty And Inspection To Be Provided. Safety And Standards International Standards Risk Classification - Class B (ghtf Rule 11);class Ii (usa); Class Ii (eu, Japan, Canada And Australia) International Standards - Iso 13485, Fda, Ce. Delivery Period 90 Calendar Days From Receipt Of The Notice To Proceed Terms Of Payment Upon Full Delivery, Installed, Tested And Commissioned Service Center Must Have Service Center Within Caraga Regional, Cebu City, Cdo Or Davao City Post Qualification The Bidder Is Required To Send A Demo Unit To Caraga Regional Hospital. Failure To Comply With The Preferred Schedule Of The Procuring Entity For The Post Qualification Can Be A Ground For Disqualification. (no Extensions Allowed) 3. 6 In 1 Patient Vital Signs Simulation / Nibp, Spo2, Ecg, Temperature, Ibp, And Respiration Functionality Test. Description Patient Category A Medical Device Tester Is Responsible For Ensuring That Medical Devices Meet Quality And Safety Standards. They May Work With A Variety Of Devices, From Blood Pressure Monitors To Pacemakers Purpose Of Use Clinical Or Other Purpose Calibration Of Your Measuring Instruments Has Two Objectives. It Checks The Accuracy Of The Instrument And It Determines The Traceability Of The Measurement. In Practice, Calibration Also Includes Repair Of The Device If It Is Out Of Calibration. 6 In 1 Patient Vital Signs Simulation: • Nibp, Spo2, Ecg, Temperature, Ibp, And Respiration Functionality Test. Clinical Department /ward Biomedical Department Technical Specifications Detailed Requirements Displayed Parameters User Adjustable Settings Non-invasive Blood Pressure Simulation: Waveform: Oscillometric Pulse Volume: High, Medeum,low, Pediatric Heart Rate; 20-300bpm Integrated Pump; 0 To 350mmhg User Configuration Leak Test: User Configurable Between 0-350mmhg Chronometer; Configurable Up To 999 – 1100 Secs) Digital Manometer: 0-410mmhg Pressure Accuracy: +/- 0.5% Fs Pressure Unit: Mmhg, Inhg, Kg/cm2. Cmh20, Mbar, Psi, In H20 And Kpa Oxygen Saturation Simulation(puls-r): Range: 30 To 100% Repeatability; Positive/negative 5% Of Reading Between 30-59% Spo2 Positive/negative 3% Of Reading Between 60-89% Spo2 Positive/negative 1% Of Reading Between 90-100% Spo2 ( Accuracy Of Simulation When Used With The Corresponding R-curves Based In Using The Same Probe And Monitor Set Up . Note That Some Montor Type Might Not Be Able To Display Low Range Sats) Heart Rate: 30-300bpm Accuracy: Positive/negative 1bpm Compatibility: Beijing Choice, Criticare, Ge Tuffsat, Masimo, Mindray, Nellcor, Nellcor Oximas, Nihon Kohden, Nonin, Novametrix, Philips,/hp Ecg Arrhythmia Simulator: Simulation: 5 Lead Simulation Including High Level Output On Normal Sinus Rhythm (nsr), St Elevation, St Depression, Myocardial, Infarction, Tall T Heart Rate: 20-300bpm Accuracy: Positive/negative 1 Bpm Amplitudes; Lead Ii: 0.5 -5 Mv (in Steps Of 0.5 Mv). Other Leads Are Proportional To Lead Ii By The Following Percentage: Lead I : 60% Lead Ii : 100% Lead Iii : 40% Accuracy: Positive/negative 2% Connection High Level Ecg 3.5mm Jack Plug St Elevation /depression: Heart Rate: 20-300bpm Elevation %: 7%, 13%, 20% Elevation Slope: Positive, Negative, Flat Myocardial Infarction: Type: Ischemia, Injury, Infarction, Inferior Infarction Heart Rate: 20-300bpm Tall T: Heart Rate: 80 Bpm (ranges 75-80) T Wave Amplitude: 0-1.2mv (steps Of 0.1mv) Arrhythmia Waveforms (atrial); Simulation: 5 Lead Simulation Amplitudes: 0.5 / 1 / 1.5 / 2 / 2.5 / 3 / 3.5 / 4 / 4.5 / 5 Mv. Heart Rate ( When Applicable ) 20 – 300bpm Atrial: Sinus Arrhythmia (sa), Missing Beat, Atrial Flutter (aflt), Atrial Fibrillation (afb), Paroxysmal Atrial Tachycardia (pat), Junctional Premature Contraction. Atrial Conduction: First Degree Av Block, Second Degree Av Block – Mobitz I, Second Degree Av Block – Mobitz Ii, Third Degree Av Block, Right Bundle Branch Block (rbb), Left Bundle Branch Block (lbb), Left Anterior Hemiblock. Ventricular: Premature Ventricular Contraction – Intermittent Premature Ventricular Contraction – Continuous Bigeminy, Trigeminy, Ventricular Flutter (vflt), Ventricular Fibrillation Fine (vfbf), Ventricular Fibrillation Coarse ( Vfbc), Monomorphic Ventricular Tachycardia (mvt), Polymorphic Ventricular Tachycardia (pvt) Right Focal (pvc). Performance Waveforms: Shape: Sine, Square, Triangle Rate: 0.1 To 0.9hz (in Steps Of O.1hz) 1 To 100hz (in Steps Of 1hz) Amplitude: Lead Ii : 0.5-5 Mv (in Steps Of 0.5 Mv) Other Leads As Above Accuracy: 2% Shape: Pulse Rate: 20 Ms Pulse Duration, 4 Second Delay Amplitude: Lead Ii : 1 Mv. Other Leads As Above Accuracy: 2% Pacer Waveforms: Available: Synchronous Atrial, Asynchronous Atrial, Paver Only, Ventricular Pacer, Atrial & Ventricular Pacer. Qrs: 1mv Pacer Pulse Amplitude: 0.1-2mv Pacer Pulse Polarity: Positive/negative Pacer Pulse Width: 0.1-2ms R Wave Detection: Heart Rate: 70 Bpm R Wave Width; 10-120ms (steps Of 10ms) Temperature Simulation: Simulation; Ysi 400 / 700 Static Range; Preset At 25, 23, 37, And 41c Accuracy: ± 0.1c Default Setting: Ysi 400 37c Respiration Simulation: Rates; 5, 10, 15, 30, 60, 120, 180 Breaths Per Minute Base Resistance: 250, 500, 750, 1000 Ohms Accuracy: ± 10% Resistance Variation: 0.1, 0.5, 1.0, 1.5 Ohms Accuracy: ± 10% Default Setting: 15bpm / 250ω / 0.1ω Apnoea Simulation: 0-60 Seconds Duration 0-300seconds Interval Invasive Blood Pressure Simulation; Channels: 2 Channels Static: 0 To 300mmhg Dynamic: 0-300mmhg For Systolic 6 Diastolic Accuracy: ±1mmhg Excitation Voltage: 2 – 16v Impedance: 350ω Nominal Simulated Sensitivity: 5µv / V /mmhg Basic Specification: Operation; Battery Cell, In-site Charge Battery Charger: 100-240vac, 50/60hz Supply; 12 Vdc Centre Positive Battery Life: 8 Hours Standby Or A Maximum Of 200 Nibp Simulations Memory Capacity; Approx. 5, 000 Records Communication: Bluetooth Display: Monochrome, ¼ Vga Full Graphics Keypad: Alpha Numeric Weight: < 1.5 Kg, <3.5lbs Size (lxwxd): 250-270 X 100 To 110 Mm / 10.5 X 4 X3 Operating Environment: - 15° - + 60°c Environmental Protection: Ip 40 Puls-r: Compatibility Beijing Choice, Ge Tuffsat, Mindray, Nellcor Oximax, Nonin, Philips / Hp, Criticare, Masimo, Nellcor, Nihon Kohden, Novametrix Supported Default R-curves Heart Rating: 30 – 300bpm Accuracy Of Simulation When Used With The Corresponding R Curves: Resolution 1% Steps - Range 30-59% - Repeatability ± 5% 1% Steps -range 60 – 89% - Repeatability ±3 % 1% Steps -range 90 – 100% - Repeatability ±1% Technical Services As Follows: • System Warranty Must Be Five (5) Years • Calibration Of The Unit Must Be Performed After Installation With Certificate • Service Call Within 24 Hours Maximum And Must Have Repair Facility In Mindanao Area. • Preventive Maintenance For Every Quarter Until Warranty Expires. • Service Kits And Consumables To Be Included For One Year Use. • Supplier Must Deliver And Install The Unit Without Cost To The Owner Accessories, Consumables, Spare Parts, Other Components Accessories: • Ibp Connection Cable • Nibp Accessories • Temperature Connect Cables • Ecg Cables And Leads • Puls-r Universal Spo2 Simulation Finger Standard Accessories: • Carry Case • Nibp Tubing Kit • Ecg Adaptor Module And Snap-on Adaptors • Quick Start Guide • Power Supply Training, Installation And Utilisation Pre-installation Requirements Supplier To Perform Installation, Safety And Operation Checks Before Handover. Requirements For Commissioning 1. Local Clinical Staff To Affirm Completion Of Installation, 2. Calibration Certificate And Warranty Certificate 3. The Supplier Must Have A Track Record/history/experience For Having A Calibration Center Within The Philippines For Assurance Of Being A Biomedical Company. 4. The Supplier Must Have A Certificate Of Being An Authorized Service Partner. 5. The Supplier Must Have A Branch Office In The Mindanao For Technical Support Purposes. 6. The Supplier Must Have A Local Business Permit For Services In The Mindanao Area. Training Of User/s 5 Days Training Of User Biomed Engineer & Staff In Operation, Basic Maintenance And Documentation , Shall Be Provided User Care To Demonstrate The Proper Cleaning And Disinfection With Provision Of Printed Cards Or Tags Beside The Unit. Warranty And Maintenance Warranty • 5 Years For Parts And Labor • Cleaning And Maintenance Of Machine • Shall Have Spare Parts Availability Once The End User Needs It. Environmental Factors • Capable Of Being Stored Continuously In Ambient Temperature Of 0 To 50 Deg C And Relative Humidity Of 15 To 90%. • Capable Of Operating Continuously In Ambient Temperature Of 10 To 40 Deg C And Relative Humidity Of 15 To 90% Documentation Documentation Requirements User, Technical And Maintenance Manuals To Be Supplied In English Language. Service Manual In English. List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost. Certificate Of Calibration, Warranty And Inspection To Be Provided. Safety And Standards International Standards Risk Classification - Class B (ghtf Rule 11);class Ii (usa); Class Ii (eu, Japan, Canada And Australia) International Standards - Iso 13485, Fda, Ce. Delivery Period 90 Calendar Days From Receipt Of The Notice To Proceed Terms Of Payment Upon Full Delivery, Installed, Tested And Commissioned Service Center Must Have Service Center Within Caraga Regional, Cebu City, Cdo Or Davao City Post Qualification The Bidder Is Required To Send A Demo Unit To Caraga Regional Hospital. Failure To Comply With The Preferred Schedule Of The Procuring Entity For The Post Qualification Can Be A Ground For Disqualification. (no Extensions Allowed) 4. Gas Flow Equipment Analyzer Description Patient Category Test Gas Flow And Respiratory Medical Equipment Accurately, Including Ventilators, Flow Meters, Edoscopic Insufflators, Suction Devices, Pressure Gauge And Anaesthesia Machine, Especially When Accuracy Of Low Volume And Pressure Is Crucial. Purpose Of Use Clinical Or Other Purpose Calibration Of Your Measuring Instruments Has Two Objectives. It Checks The Accuracy Of The Instrument And It Determines The Traceability Of The Measurement. In Practice, Calibration Also Includes Repair Of The Device If It Is Out Of Calibration. 5 In 1 Gas Flow Equipment Analyzer • Ventilators, Flow Meters, Pressure Gauge, Suction Machine And Anesthesia Machine Clinical Department /ward Biomedical Department Technical Specifications Flow And Pressure Measurements: Flow: Range: Accuracy: Measuring Direction * Bidirectional Temperature Compensated * Automatic Or Manual Pressure Compensated *automatic Humidity Compensated *- Manually High Flow * ±300 L/min , * ±1.9% Or 0.1 L/min (for 10..40°c) Pressure: High Pressure (p High) * -1 – 9 Bar * ±0.5-1% °or ±6-7 Mbar Differential Pressure (p High): * ±180-200mbar * ±.05-0.75% Or ±0.5-0.1mbar Pressure In High Flow Channel: * - 55-150mbar * ±0.75% Or 0.1mbar Atmospheric Pressure: * 550-1150mbar * ±1% Or ± 5mbar Units: Flow: * L/min, L/s, Cfm, Ml/min, Ml/s Pressure: * Bar, Mbar, Cmh20, Inh20, Torr, Inhg, Hpa, Kpa, Mmhg, Psi Other Measurement: Oxygen; Concentration; * 0-50% * ±15 O2 Pressure Compensated; * ≤100-150mbar Temperature: In High Flow Channel: * 0-55°c * ±1.75% Or ±0.5% °c Co2: Concentration * 0-16 Vol% * ±(0.2vol% + 2% Of Reading) N2o: Concentration * 0-90 Vol% * ±(2% Vol% + 2% Of Reading) Hal, Iso,enf: Concentration * 0-8% Vol% * ±(0.15% + 5% Of Reading) Sev Concentration *1-10% Vol% * ±(0.15% Vol% +5% Of Reading) Des Concentration * 0-20 Vol% * ±(0.15 Vol% +55 Of Reading) Gas Type: * Air,o2, Air/o2, N2o, N2o/o2, He/o2, N2,c02, Gas Standards: * Atp, Atpd, Atps, Ap21, Stp, Stph, Btps, Btps-a, Btpd, Btpd-a, 0/1013, 20/981, 15/1013, 25/991, 20/1013, Ntpd, Ntps Ventilation Parameters: Breath Rate: Rate: * 1-980 Bpm * ±0.5 Bpm Or ±0.5-5% Or 2.0 Time Ti Te * 0.04 – 60 S * ±0.01-0.02 S Ratio I:e * 1:300-300:1 * ±2.5% * 0-90% * ±3-5% Breath Volumes V: * * ±2% Or 0.20ml (> 6 Sl/min) Vti,vte: * ±10l * ±2% Or ±2.20ml (>6 Sl/min) Minute Volume Vi, Ve: * 0-299sl/min * ±2.5% Pressure P Peak, P Mean, Peep, P Plateau, Ipap: * 2-150 Mbar * ±0.75% Or ±0.1mbar Peakflow Pf Insp1, Pf Xp : * ±300 Sl/min * ±1.9% Or ±0.1% Sl/min Compliance C Stat * 1-1000 Ml/mbar * ±3% Or ±1ml/mbar Trigger Adult, Pediatric, Hfo Ext. Trigger * Adult, Pediatric Hfo, Adjustable On Flow Or Pressure Curves With User Defined Limits General Information; Power: * 100-240vac, 50/60hz Battery * 3-5 Hours Power Consumption * 3-6 W Weight * 0.52-1kg Dimension ( W X D Xh) * 11.4x 7x 7.3cm Depends Of The Manufacturer) Data Storage * Internal And Micro Sd Display * Multi Touch (color) , Realtime Curves Interfaces * Rs-232, Usb , Ethernet, Can, Analog Out, Ttl, Wlan, Tsi4000 And Prima Protocool Calibration * Annually Condition Ambient Temperature * 20-40°c (*59-104°f) Condition Humidity * 20-90% R,h Technical Services As Follows: • System Warranty Must Be Five (5) Years • Calibration Of The Unit Must Be Performed After Installation With Certificate • Service Call Within 24 Hours Maximum And Must Have Repair Facility In Mindanao Area. • Preventive Maintenance For Every Quarter Until Warranty Expires. • Service Kits And Consumables To Be Included For One Year Use. • Supplier Must Deliver And Install The Unit Without Cost To The Owner Accessories, Consumables, Spare Parts, Other Components Accessories: • Stand • Smartlung Adult (1l) • Webserver Configurator And Monitoring • Flow Lab Software • Oxygen Sensor • Adapter Set • Laminar Flow Tube • Car Adapter • Micro Sd Memory Card • Protection Filter • Usb Cable • Ethernet Cable • Power Supply • Battery Pack • Usb Adapter • Manual • Protector • Carrying Bag Training, Installation And Utilisation Pre-installation Requirements Supplier To Perform Installation, Safety And Operation Checks Before Handover. Requirements For Commissioning 1. Local Clinical Staff To Affirm Completion Of Installation, Calibration Certificate And Warranty Certificate 2. The Supplier Must Have A Track Record/history/experienced For Having A Calibration Center Within The Philippines For Assurance Of Being A Biomedical Company. 3. The Supplier Must Have A Certificate Of Being An Authorized Service Partner. 4. The Supplier Must Have A Branch Office In The Mindanao For Technical Support Purposes. 5. The Supplier Must Have A Local Business Permit For Services In The Mindanao Area. Training Of User/s 5 Days Training Of User Biomed Engineer & Staff In Operation, Basic Maintenance And Documentation , Shall Be Provided User Care To Demonstrate The Proper Cleaning And Disinfection With Provision Of Printed Cards Or Tags Beside The Unit. Warranty And Maintenance Warranty • 5 Years For Parts And Labor • Cleaning And Maintenance Of Machine • Shall Have Spare Parts Availability Once The End User Needs It. Environmental Factors • Capable Of Being Stored Continuously In Ambient Temperature Of 0 To 50 Deg C And Relative Humidity Of 15 To 90%. • Capable Of Operating Continuously In Ambient Temperature Of 10 To 40 Deg C And Relative Humidity Of 15 To 90% Documentation Documentation Requirements User, Technical And Maintenance Manuals To Be Supplied In English Language. Service Manual In English. List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost. Certificate Of Calibration, Warranty And Inspection To Be Provided. Safety And Standards International Standards Risk Classification - Class B (ghtf Rule 11);class Ii (usa); Class Ii (eu, Japan, Canada And Australia) International Standards - Iso 13485, Fda, Ce. Delivery Period 90 Calendar Days From Receipt Of The Notice To Proceed Terms Of Payment Upon Full Delivery, Installed, Tested And Commissioned Service Center Must Have Service Center Within Caraga Regional, Cebu City, Cdo Or Davao City Post Qualification The Bidder Is Required To Send A Demo Unit To Caraga Regional Hospital. Failure To Comply With The Preferred Schedule Of The Procuring Entity For The Post Qualification Can Be A Ground For Disqualification. (no Extensions Allowed) This Procurement Is A Partial Bid Or Line Item Bid. Validity Of The Contract Without Prejudice To The Provision Of Applicable Laws, Rules And Guidelines, The Contract Shall Be Automatically Terminated Under The Following Conditions: A. When The Total Quantity Specified In The Contract Has Been Exhausted; Or B. For Any Justifiable Reason Ground Where The Contract Will Not Redound To The Benefit Of The Government Or There Is Violation Of The Contract. General Conditions All Other Rules Governing Contract Implementation And Termination Under Ra 9184 And Its Irr, And Relevant Procurement Policies Shall Be Applicable. Technical Specifications And Terms Of Reference Is Hereby Posted In Philgeps And Form An Integral Part Of This Invitation To Bid. 2. The Crh Now Invites Bids For The Procurement Of The Above-captioned Project. Delivery Of The Goods Is Required Within The Period Specified Under Section Vi (schedule Of Requirements). Bidders Should Have Completed, Within Two (2) Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. Section 23.4.1.3. (ra 9184) The Bidder Must Have Completed A Single Contract That Is Similar To This Project, Equivalent To At Least Fifty Percent (50%) Of The Abc. Slcc Must Be Within 2 Years From The Submission Of Bids. (based On The Completion Date). Slcc Shall Be The Same Or Similar In Nature, Which Shall Be Determined By The Bids And Awards Committee. For Procurement Where The Procuring Entity Has Determined, After The Conduct Of Market Research, That Imposition Of Either (a) Or (b) Will Likely Result To Failure Of Bidding Or Monopoly That Will Defeat The Purpose Of Public Bidding: The Bidder Should Comply With The Following Requirements: A. Completed At Least Two (2) Similar Contracts, The Aggregate Amount Of Which Should Be Equivalent To At Least Fifty Percent (50%) In The Case Of Non-expendable Supplies And Services Or Twenty-five Percent (25%) In The Case Of Expendable Supplies] Of The Abc For This Project; And B. The Largest Of These Similar Contracts Must Be Equivalent To At Least Half Of The Percentage Of The Abc As Required Above. 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Nondiscretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) 9184, Otherwise Known As The “government Procurement Reform Act”. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra 5183. 4. Interested Bidders May Obtain Further Information From The Bids And Awards Committee (bac) Secretariat, At Procurement Section, Caraga Regional Hospital, Surigao City And Inspect The Bidding Documents At The Address Given Above During 8:00 Am – 5:00 Pm, Monday To Friday. 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On December 10, 2024 – January 21, 2025 On Or Before 10:00 A.m. From The Address Above And Upon Payment Of The Applicable Fee For The Bidding Documents, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Specified Below: Bidding Schedule Pre-bidding Conference December 18, 2024 At 9:00 O’clock In The Morning Via Zoom Platform Link: Join Zoom Meeting Https://us06web.zoom.us/j/83066464127?pwd=umvcd4lcmrkaz6ldz2qhqbhw76cdzk.1 Meeting Id: 830 6646 4127 Passcode: 528376 Deadline Of Submission Of Bids January 21, 2025 At 10:00 A.m... Via Online And Submit Your Bidding Documents To This Email Address: Crhbac2020@gmail.com . Please Be Advised That Failure To Submit Bidding Documents To The Designated Official Email Address Will Result In Automatic Rejection And Disqualification. Opening Of Bids January 21, 2025 At 2:00 P.m. Via Zoom Platform. Join Zoom Meeting Https://us06web.zoom.us/j/85126317644?pwd=pqhrftd91zoxlr4ufcctyy7gtdz5qj.1 Meeting Id: 851 2631 7644 Passcode: 872092 Complete Philippine Bidding Documents Please Click The Link Below For The Complete Pbd: Https://drive.google.com/drive/folders/1enb1ofcvp2zs4qembcxjjpeilwkths5c?usp=sharing Payment Of Bidding Documents Php 5,000.00 It May Also Be Downloaded Free Of Charge From The Website Of The Philippine Government Electronic Procurement System (philgeps) And The Website Of The Procuring Entity, Provided That Bidders Shall Pay The Applicable Fee For The Bidding Documents Not Later Than The Submission Of Their Bids. The Following Phlippine Bidding Documents Can Be Accessed In The Philgeps, To Wit: A. Technical Specification / Terms Of Reference/ List Of Items B. Instruction To Bidders: B.1. Documents To Be Submitted (checklist- This Will Be Discussed During The Pre-bid Conference) B.2. Memorandum Of Undertaking – Provision Thereof Is Strictly Implemented C. Guidelines On The Conduct Of The Electronic Submission And Receipt Of Bids By The Procuring Entity – Caraga Regional Hospital (crh) D. Philippine Bidding Documents 6. The Crh Will Hold A Pre-bid Conference On The Above-mentioned Date, Time And Venue, Which Shall Be Opened To Prospective Bidders. The Pre-bidding Conference And Opening Of Bids Shall Be Conducted Through Videoconferencing, Webinar Or Virtual. Please Send Your Intent To Participate To Our Email Address As Provided Below. 7. Bids Must Be Duly Received By The Bac Secretariat At Via Designated Email On Or Before January 21, 2025 At 10:00 O’clock In The Morning. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 18. Bid Opening Shall Be On January 21, 2025 At 2:00 O’clock In The Afternoon At The Bac Conference Room, Beside Procurement Office, Caraga Regional Hospital, Rizal Street, Surigao City As Virtual / Electronic Bidding Via Zoom Platform. Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend At The Address Above. Late Bids Shall Not Be Accepted Under Any Circumstances May It Cause. 8. Furthermore, The Standard Philippine Bidding Document (pbd) Is Form And Part Of This Invitation In Accordance To Ra 9184 And Other Applicable Laws, Rules And Policy. 9. The Crh Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Section 41 Of Ra 9184 And Its Irr, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 10. The Opening And Receipt Of Bids Is Strictly Implemented Through Electronic Submission. Given The Covid-19 Pandemic, Procurement Activity Has Been Expedient And One Of This Is The Conduct Of Electronic Submission Of Bids. The Crh Thru The Bids And Awards Committee (bac) Has Submitted Certification, Certified By The Highest Official Managing The Information Technology, Describing The Electronic System Or Procedure To Be Used By The Crh For The Electronic Submission And Receipts Of Bids And A Statement That The Same Is Compliant With The Gppb Resolution No. 12-2020 Requirements. 11. Bidding Documents Shall Be Emailed To This Email Address, With Activated Password To: Crhbac2020@gmail.com. You May Deposit On Line For The Payment Of The Bidding Documents To This Account Below: Bank Name: Land Bank Of The Philippines Account Name: Caraga Regional Hospital-trust Fund Account Number: 0982 -1288 – 70 12. Furthermore Deposit Slip Shall Be Submitted Via Email To: Crhprocurement.bac@gmail.com 13. The Procuring Entity Will No Longer Accept Nor Entertain Any Form Of Bids Submission Except Electronic. Failure To Comply Electronic Submission Will Be Immediately Disqualified. Guideline On The Electronic Submission Is Hereby Attached. 14. Join The Caraga Regional Hospital Supplier Network By Filling Out The Registry Form From This Link : Https://bit.ly/crh_suppliersregistry 15. For Further Information, Please Inquire To: Bac Secretariat Caraga Regional Hospital. Rizal Street, Surigao City Tel. Nos. (086) 826-1575 Local 194 Direct Line: (086) 826-9058 Mobile Nos. 09850508783 (smart/tnt) 09539212832 (globe/tm) E-mail Address: Crhprocurement.bac@gmail.com Approved By: (sgd) Fermarie C. Dulpina, Rmt, Mpa, Jd Chief Health Program Officer Chairman, Bids And Awards Committee
Contact
Tender Id
75e67e12-b826-3df9-83ac-eb336fe0aad2Tender No
11593244Tender Authority
Caraga Regional Hospital ViewPurchaser Address
-Website
http://notices.ps-philgeps.gov.ph