Cable Tenders

Cable Tenders

The City Of Dagupan Tender

Machinery and Tools...+1Furnitures and Fixtures
Philippines
Details: Description Item No. Item Description Qty Unit Approved Budget For Contract 1 Adding Machine, Compact Type Printing Calculator, 12 Digit, 2-color Printing 3 Unit 19,845.00 2 Air Conditioner, Split Type, Standard Inverter, 1.5hp, With Installation 1 Unit 78,148.80 3 Air Conditioner, Split Type, Standard Inverter, 2.0hp, With Installation 1 Unit 81,658.80 4 Air Conditioner, Window Type, Non-inverter, 1.0hp, Auto Air Swing 1 Unit 30,882.10 5 Air Conditioner, Window Type, Non-inverter, 1.5hp, Auto Air Swing, With Remote 2 Unit 80,184.60 6 Airport Chair, Powder Coated Steel, 5 Seater 1 Unit 14,256.00 7 Airport Chair, Stainless Steel, 5 Layers 1 Unit 22,943.25 8 Audio Speaker, 1000watts, With Stand 1 Unit 23,625.00 9 Base Radio 1 Unit 16,200.00 10 Blinds, Customized Size 5 Set 40,500.00 11 Computer Cpu, Basic I3 Processor, Basic Ddr4 Motherboard, 8gb Memory, 240gb Solid State Drive, 1tb Hard Disk Drive, Generic Cpu Case With Psu 2 Unit 63,760.50 12 Computer Cpu, Intermediate I5 Processor, Basic Ddr4 Motherboard, 8gb Memory, 240gb Solid State Drive, 1tb Hard Disk Drive, Generic Cpu Case With Psu 2 Unit 78,138.00 13 Computer Desktop, Advanced I7 Processor, Basic Ddr4 Motherboard, 8gb Memory, 240gb Solid State Drive, 1tb Hard Disk Drive, Generic Cpu Case With Psu, 24" Monitor 1080p, With Keyboard And Mouse 1 Set 65,696.40 14 Computer Desktop, Basic I3 Processor, Basic Ddr4 Motherboard, 8gb Memory, 240gb Solid State Drive, 1tb Hard Disk Drive, Generic Cpu Case With Psu, 24" Monitor 1080p, With Keyboard And Mouse 1 Set 44,676.90 15 Computer Desktop, Intermediate I5 Processor, Basic Ddr4 Motherboard, 8gb Memory, 240gb Solid State Drive, 1tb Hard Disk Drive, Generic Cpu Case With Psu, 24" Monitor 1080p, With Keyboard And Mouse 3 Set 155,596.95 16 Computer Monitor, 19.5" 1440x900 Resolution, 60hz, Vga 1 Unit 6,338.25 17 Computer Monitor, 21.5", 1920x1080 Resolution, 75hz, Vertical Alignment, Vga Or Hdmi 2 Unit 16,996.50 18 Digital Photocopier, Multi Function, Monochrome, Laser Print Technology, 23ppm On A4 1 Unit 69,907.86 19 Digital Photocopier, Multi Function, Monochrome, Laser Print Technology, 40ppm On A4 1 Unit 79,752.60 20 Dining Table With Four (4) Chairs 1 Set 20,822.00 21 Electric Fan, Ceiling Orbit Fan, 16" Banana Blade 12 Unit 28,674.00 22 Electric Fan, Industrial Fan, 24" Stainless Steel Blade, Thermal Fuse Protected 5 Unit 49,950.00 23 Electric Fan, Stand Fan, 16" Banana Blade, Wheel Base 3 Unit 7,593.75 24 Electric Fan, Wall Fan, 16" Banana Blade 5 Unit 11,947.50 25 Electric Stove, Double Burner 1 Unit 3,631.50 26 Electric Stove, Single Burner 1 Unit 2,200.50 27 Exhaust Fan, 8" 4 Unit 8,120.00 28 Handheld Radio - No. Of Memory Channels: 207 (incl. 6 Scan Edges And 1 Call), Operating Temperature Range: -20°c To +60°c; -4°f To +140°f; Power Supply Requirement: 7.2 V Dc; Dimensions: 58x112x30mm; 2.28x4.41x1.18 Inches; Weight (approx.): 140g; 4 9 Oz ( 8 Unit 104,000.00 29 Hard Disk Drive, External, 1tb, Usb 3.0 3 Unit 13,162.50 30 Hard Disk Drive, External, 2tb, Usb 3.0 2 Unit 13,176.00 31 Hard Disk Drive, External, 4tb, Usb 3.0 1 Unit 8,775.00 32 Hydroponics Grower Tower, 75 Holes (15 Layers X 5 Holes) 5 Unit 47,250.00 33 Kids Toy Storage Rack Children's Multi Purpose Display Book Organizer 1 Unit 4,500.00 34 Laptop Computer, Advance I7 Processor, 8gb Ram, With 2gb Graphics Processing Unit, Full Hd Resolution 1080p, With Operating System, With Laptop Bag 3 Unit 214,609.50 35 Laptop Computer, Basic I3 Processor, 8gb Ram, With 2gb Graphics Processing Unit, Full Hd Resolution 1080p, With Operating System, With Laptop Bag 2 Unit 99,897.30 36 Laptop Computer, Intermediate I5 Processor, 8gb Ram, Full Hd Resolution 1080p, With Operating System, With Laptop Bag 1 Unit 56,698.65 37 Laptop Computer, Intermediate I5 Processor, 8gb Ram, With 2gb Graphics Processing Unit, Full Hd Resolution 1080p, With Operating System, With Laptop Bag 1 Unit 62,098.65 38 L-shaped Sofa Set With Additional 2 Single Seater Stool Type, Fabric, Avocado Green 1 Set 22,614.20 39 Microphone, Dual Wireless Uhf Microphone, Dynamic Capsule 2 Unit 13,497.30 40 Microwave Oven, 20 Liters 3 Unit 16,191.90 41 Mobile Phone, Min. 8 Cores Processor, Gsm/hspa/lte Technology, 1080p Resolution, Min. 6gb Ram, Min. 128gb Storage, Min. 4000mah Battery, Dual Band Wifi, Usb Type C, With Charging Adaptor And Cable 1 Unit 27,000.00 42 Mobile Wifi, 4g/lte, Internal 4g Modem 2 Unit 10,665.00 43 Mouse, Wireless, 200-12,000 Dpi, Lightsync Rgb 3 Unit 17,815.95 44 Office Chair, Clerical, Mesh, Gaslift Swivel, With Arm Rest 3 Unit 15,390.00 45 Office Chair, High Back, Leather, Gaslift Swivel, With Arm Rest 1 Unit 14,715.00 46 Office Chair, High Back, Mesh, Gaslift Swivel, With Arm Rest 6 Unit 57,915.00 47 Office Chair, Mid Back, Mesh, Gaslift Swivel, With Arm Rest 3 Unit 18,711.00 48 Office Chair, Mid Back, Mesh, Gaslift Swivel, With Head Rest, With Arm Rest 3 Unit 27,945.00 49 Office Table, Steel, With Center Drawer, 100x60 2 Unit 16,839.90 50 Office Table, Steel, With Center Drawer, 100x60, With Pedestal Cabinet 8 Unit 105,483.60 51 Office Table, Steel, With Center Drawer, 120x60 1 Unit 10,840.00 52 Office Table, Steel, With Center Drawer, 120x60, With Pedestal Cabinet 2 Unit 31,212.00 53 Office Table, Steel, With Center Drawer, 140x70, With Pedestal Cabinet 7 Unit 123,483.15 54 Oven Toaster, 9 Liters 2 Unit 4,320.00 55 Paper Shredder, 8 Sheets, 13 Liters Bin 1 Unit 5,670.00 56 Paper Shredder, 8 Sheets, 22 Liters Bin 4 Unit 73,224.00 57 Portable Public Address System, With 1 Wireless Handheld Microphone 2 Unit 43,200.00 58 Portable Speaker, 2000watts, With 2 Wireless Microphones, With Built In Karaoke, Battery And Ac Powered 1 Unit 21,735.00 59 Presenter, Laser Pointer, Wireless 2 Unit 5,907.60 60 Printer, All In One, Ink Jet Tank, 10/5 Ipm Mono/color 12 Unit 161,919.00 61 Printer, All In One, Ink Jet Tank, 10/5 Ipm Mono/color, Wi-fi Direct 10 Unit 161,932.50 62 Printer, All In One, Ink Jet Tank, Duplex Printing, With Auto Document Feeder 1 Unit 20,000.00 63 Printer, All In One, Ink Jet Tank, With Cd/dvd Printing 2 Unit 58,306.50 64 Printer, Impact Dot Matrix, 9-pin 1 Unit 17,273.25 65 Printer, Single Function, Ink Jet Tank 3 Unit 33,189.75 66 Projector, 3600 Ansi Lumens, 16:9 Supported 1 Unit 28,348.65 67 Rice Cooker, 10 Cups, 1.8 Liters, With Steamer, Drum Type 1 Unit 2,004.75 68 Rice Cooker, 15 Cups, 2.2 Liters, With Steamer, Drum Type 6 Unit 14,231.70 69 Scanner, 26ppm On 200dpi Monochrome Scanning Speed, Sheetfed Scanner, 50 Sheets Capacity Adf 1 Unit 37,800.00 70 Scanner, Sheet-fed, One-pass Duplex Color, Up To 35/70 Ipm On 600 Dpi, Automatic Two-sided Scanner, 50 Sheets Capacity Adf 1 Unit 42,628.60 71 Shelves, Stainless Steel, 5 Layers 1 Unit 17,138.25 72 Shelves, Steel Type, 5 Layers 1 Unit 7,000.00 73 Steel Cabinet, Lateral, 3 Drawers 4 Unit 78,624.00 74 Steel Cabinet, Lateral, 4 Drawers 2 Unit 55,971.00 75 Steel Cabinet, Vertical, 4 Drawers 2 Unit 29,295.00 76 Switch Hub, 16ports 2 Unit 4,708.80 77 Switch Hub, 24ports 1 Unit 5,130.00 78 Table, Computer Table 1 Unit 2,700.00 79 Table, Conference Table, Wood 1 Unit 6,750.00 80 Table, Folded In Half, Steel Frame, Plastic Material, 72" 2 Unit 11,400.00 81 Table, Folding, Steel Frame, Plastic Material, 72" 4 Unit 21,600.00 82 Television, Smart Tv, 43" 1 Unit 36,436.50 83 Television, Smart Tv, 55" 1 Unit 55,336.50 84 Uninterruptible Power Supply, 1200va, 650w 4 Unit 42,930.00 85 Uninterruptible Power Supply, 650va, 360w 7 Unit 30,230.55 86 Uninterruptible Power Supply, 700va, 360w, With Usb Port 6 Unit 34,425.00 87 Vacuum Cleaner, 800watts, 220v-60hz 1 Unit 7,222.50 88 Visitor's Chair, Steel Frame, Fabric Material 5 Unit 16,875.00 89 Water Dispenser, Floor Standing, Hot And Cold, Bottom Load 1 Unit 14,883.75 90 Water Dispenser, Floor Standing, Hot And Cold, Top Load 2 Unit 21,208.50 91 Water Dispenser, Floor Standing, Hot Warm And Cold, Top Load 5 Unit 62,066.25 92 Water Pump, Shallow Well, 1hp 1 Unit 15,225.00 93 Weighing Scale, For Market, 20kg 1 Unit 2,227.50 94 Wi-fi Dongle, 300mbps On 2.4ghz 1 Unit 1,485.00 95 Wi-fi Dongle, 400mbps On 2.4ghz, 867mbps On 5ghz 1 Unit 2,970.00 96 Wireless Router, 300mbps 6 Unit 14,580.00
Closing Date19 Dec 2024
Tender AmountPHP 3.6 Million (USD 61 K)

Department Of Agriculture Tender

Publishing and Printing
Philippines
Details: Description Supply And Delivery Of Office Supplies Abc: P1,696,953.25 Specifications: - 100 Bottles Alcohol, Ethyl, 68-70%, Scented, With Moisturizer, 500ml - 1500 Pieces Ballpen, Black - 1500 Pieces Ballpen, Blue, Good Quality - 50 Packs Battery, Super Heavy Duty, Dry Cell, Size Aa, 2's - 25 Packs Battery, Super Heavy Duty, Dry Cell, Size Aaa, 2's - 50 Packs Board Paper, A4 Size, 10's/pack - 80 Reams Book Paper, 210mm X 297mm (a4), 80 Gsm, 500 Sheets/ Ream - 40 Reams Book Paper, 8.5in X 11in (letter), 80 Gsm, 500 Sheets/ Ream - 1600 Reams Book Paper, 8.5in X 14in (legal), 80 Gsm, 500 Sheets/ Ream - 2 Packs Carbon Film, Pe, Black, Size: 216mm X 330mm, 100 Sheets/ Pack - 15 Packs Carbon Film, Pe, Blue, Size 216mm X 330m, 100 Sheets/ Pack - 300 Pieces Certificate Holder, Hard Case, Color: Black & Blue, A4 - 100 Pieces Certificate Holder, Legal, Color: Black & Blue - 10 Cart Cartridge For Laserjet Printer Cf276a (76a) Genuine - 40 Box Clip Backfold, 32 Mm , 12pcs/ Box - 50 Box Clip Backfold, 51 Mm, 12pcs/ Box - 10 Pieces Clipboard, Long, Hard Plastic - 350 Pieces Correction Tape, Film Base Type, Ul 10m, Strong Coverage - 5 Tube Pieces Cutter Blade, For Heavy Duty Cutter Size: 18mm X 100mm, 10pcs/ Tube - 10 Pieces Cutter/ Utility Knife, Big, 18mm X 100mm, For General Purposes, Heavy Duty - 25 Box Data File Box, Made Of Chipboard, With Closed Ends, Single, Legal - 40 Box Pieces Envelope, Expanding, Kraftboard, Legal Size, With Garter, 10 Pieces Thick, Color: Brown, 100 Pcs/box - 50 Pieces Envelope, Plastic Long - 10 Pieces Eraser, Felt, For Blackboard/whiteboard - 75 Box Box Fastener, Metal, 70mm Between Prongs, 50sets/box - 10 Box Fastener, Plastic Vinyl, Multi-colored, Non-sharp Edges, 70mm X 8 1/2 In., 50sets/ Box - 100 Box Fastener, Plastic Vinyl, Multi-colored, Non-sharp Edges, 7cm, 50sets/ Box - 3 Box Folder, Pressboard, Green, Size 240mm X 370mm, 100s/box - 2 Box Folder, Pressboard, White, Size 240mm X 370mm, 100s/box - 10 Packs Folder, Tagboard, Brown, Legal Size, Hard Board, 100pcs/ Pack - 220 Bottle Glue, Multi-purpose, Safe, Non-toxic, 130g - 5 Box Index Tabs, Transparent, Alphabet, 5ft/ Box - 10 Cart Ink Cartridge For Epson Wf-c5790, Cyan, Genuine - 10 Cart Ink Cartridge For Epson Wf-c5790, High Yield Black, Genuine - 15 Cart Ink Cartridge For Epson Wf-c5790, Magenta, Genuine - 10 Cart Ink Cartridge For Epson Wf-c5790, Yellow, Genuine - 2 Bottles Ink For Brother Bt5000, Cyan, Genuine @390.00/ Bot. - 2 Bottles Ink For Brother Bt5000, Magenta, Genuine - 2 Bottles Ink For Brother Bt5000, Yellow, Genuine - 5 Bottles Ink For Brother Btd60, Black, Genuine - 10 Bottles Ink For Brother Dcp-t420w, Black, Genuine - 5 Bottles Ink For Brother Dcp-t420w, Cyan, Genuine - 5 Bottles Ink For Brother Dcp-t420w, Magenta,genuine - 5 Bottles Ink For Brother Dcp-t420w, Yellow, Genuine - 40 Bottles Ink For Epson, 003, Black, Genuine - 10 Bottles Ink For Epson, 003, Cyan, Genuine - 10 Bottles Ink For Epson, 003, Magenta, Genuine - 10 Bottles Ink For Epson, 003, Yellow,genuine - 5 Unit Keyboard, Wired, Usb Type, Genuine - 25 Pieces Lever Arch File, Horizontal, Legal Size, 2 Rings, Black, Assembled - 25 Pieces Lever Arch File, Legal Size, Side Clip, 2 Rings, Red, Assembled - 30 Packs Linen Paper, Yellow, Legal, 180gsm, 20's Per Pack @ 130.00 Per Pack - 30 Packs Linen Paper, Green, Legal, 180gsm, 20's Per Pack @ 130.00 Per Pack - 25 Sets Marker, Fluorescent, Assorted Color: Yellow, Green, Pink, 3pcs/set - 50 Pieces Marker, Permanent, 1mm, Black, Broad Tip - 30 Pieces Marker, Permanent, 1mm, Blue, Broad Tip - 25 Pieces Marker, Whiteboard, Black, Felt Tip, Bullet Type - 25 Pieces Marker, Whiteboard, Blue, Felt Tip, Bullet Type - 10 Pieces Marker, Whiteboard, Red, Felt Tip, Bullet Type - 110 Pieces Monoblock Chair, Beige, Can Carry Upto 200kg, Strong Solid Plastic - 50 Pads Note Pad, Stick On, Sticks Securely, Removes Cleanly, Color: Pastel Green, Pastel Pink, Pastel Blue, Yellow, 50mm X 76mm (2" X 3") 100 Sheets/ Pad Min. - 100 Pad Note Pad, Stick On, Sticks Securely, Removes Cleanly, Color: Pastel Green, Pastel Pink, Pastel Blue, Yellow, 76mm X 100mm (3" X 4") 100 Sheets/ Pad Min. - 100 Pad Note Pad, Stick On, Sticks Securely, Removes Cleanly, Color: Pastel Green, Pastel Pink, Pastel Blue, Yellow, 76mm X 76mm (3" X 3") 100 Sheets/ Pad Min. - 500 Pieces Notebook, Stenographer, Spiral, 40 Leaves, Size: 153mm X 228 Mm - 50 Pieces Paper Clip, Vinyl/plastic Coated, 33 Mm - 75 Pieces Paper Clip, Vinyl/plastic Coated, 50 Mm - 5 Pieces Pen Organizer, Metal Mesh With Compartments, 3 In 1, Size: Approx. 10.5 X 20.5 X 9.5 Cm, Black - 5 Units Pencil Sharpener, Mechanical Machine, Stainless Steel With Metal Body, Suitable For 6-8mm Wooden/ Colored Pencils, Heavy Duty - 25 Box Pencil, No. 2, With Non-smudge Eraser, Lead, W/ Eraser Wood Cased, Hardness: Hb, 12pcs/box - 6 Pieces Philippine National Flag, 100% Polyester, 3ft X 6 Ft - 300 Pieces Photo Paper, Glossy, 20's, A4, Atleast 200 Gsm - 300 Packs Post-it, Sign Here, 1"x 1", 100 Sheets/ Pack, Self- Adhesive, See Through - 5 Pieces Puncher, For Paper, Heavy Duty, With Two Hole Guide - 50 Pieces Record Book, 300 Pages, Size: 214mm X 278mm Min., Color: Blue - 50 Pieces Record Book, 500 Pages, Size: 214mm X 278mm Min., Color: Blue - 6 Cart Ribbon Cart. Lx300+, Genuine - 5 Box Rubber Band, Flat, 2.0mm Thick, Elastic, 350g - 50 Pieces Scissors, Symmetrical, Multi-purpose, Heavy Duty, Blade Length: 3.5" - 25 Pieces Sign Pen, 1.0mm, Black, Roller Ball Pen, Broad/ Large - 135 Pieces Sign Pen, 1.0mm, Blue, Roller Ball Pen, Broad/ Large - 250 Pieces Sign Pen, Black, Liquid/gel Ink, 0.5mm Needle Tip - 1000 Pieces Sign Pen, Blue, Liquid/gel Ink, 0.5mm Needle Tip - 25 Pieces Sign Pen, Red, Liquid/gel Ink, 0.5mm Needle Tip - 130 Packs Specialty Paper, Board, A4, 180 Gsm, 10 Sheets/ Pack - 80 Packs Specialty Paper, Board, Legal, 180 Gsm, 10 Sheets/ Pack - 30 Packs Specialty Paper, Board, A4, 180 Gsm, 20 Sheets/ Pack, Pale Cream - 30 Packs Specialty Paper, Board, Legal, 200 Gsm, 20 Sheets/ Pack, Pale Cream - 15 Bottle Stamp Pad Ink, Purple, 30ml - 15 Pieces Stamp Pad, Felt, 97mm X 142mm, Violet With Cover - 20 Pieces Staple Remover, Plier Type, Stainless , Heavy Duty - 150 Box Staple Wire, Standard, No. 35 - 20 Pieces Stapler With Remover, Standard Type, Heavy Duty - 15 Pieces Stapler, No. 10, High Quality, Metal Body, Ergonomic Design - 20 Packs Sticker Paper, A4, Plain, 10's - 15 Roll Tape, Double-sided, 1 Inch - 15 Roll Tape, Double-sided, 2 Inch - 40 Roll Tape, Duct, 48mm, Durable - 75 Roll Tape, Masking, 24mm, Strong Adhesive, Thick And Durable - 75 Roll Tape, Masking, 48mm, Strong Adhesive, Thick And Durable - 100 Roll Tape, Packaging, Brown, 48mm, 200m/ Roll, Strong Adhesive, Thick And Durable - 150 Roll Tape, Transparent, 24mm, 50m/ Roll, Strong Adhesive, Thick And Durable - 100 Roll Tape, Transparent, 48mm, 50m/ Roll - 1 Cart Toner Cart, Hp 680, Tricolor, Genuine - 4 Cart Toner, Canon 303 (original Black) - 5 Roll Twine, Made Of Banana 300m/ Roll, 1kg - 10 Roll Twine, Plastic, 1kg/ Roll Cleaning Materials - 100 Cans Air Freshener, (lemon, Lavender) Min. 300ml, Quality Fragrance, Long Lasting Freshness - 75 Pieces Bathroom Deodorizer, 100g With Holder - 50 Pieces Broom, Soft (tambo) - 50 Pieces Broom, Stick (ting-ting), Usable Length: 760mm Min. - 30 Pieces Brush, Multi-purpose Plastic Brush W/ Handle - 150 Bottle Cleaner, Toilet And Urinal, 1l - 25 Packs Detergent Powder, All- Purpose, 1kg - 50 Bottles Disinfectant Concentrate, 350ml - 70 Bottles Disinfectant, Multi Purpose Cleaner And Surface Disinfectant Bleach, Il/bot. - 6 Pieces Dispenser For Tissue Jumbo Roll (200m), Plastic, Grey, Transparent, Durable - 10 Pieces Dust Pan, Non-rigid, Plastic - 350 Sachet Fabric Conditioner, 24ml/ Sachet - 100 Cans Furniture Polish, Multi-surface Cleaner, 300ml, Aerosol Type, Scent: Lavender, Lemon Oil - 50 Bottle Hand Soap, Liquid, 500ml - 2 Pieces Mop Bucket Squeezer, 32l, With Wringer, Heavy Duty, Hard Plastic - 30 Pieces Mop Head, Cotton Yarn - 30 Pieces Mop Head Handle, Screw Type With Aluminum Handle - 25 Bottle Muriatic Acid, 500ml - 25 Pair Rubber Gloves, Size: Long, Multi-purpose, Latex, Durable And Thick, Reusable - 30 Bottle Sink Drain Declogger, 250ml, Contains 50% Sodium Hydroxide - 30 Pieces Scouring Pad With Sponge, 115mm X 70mm X 30mm, Anti Bacterial - 12 Box Tissue Paper, Jumbo Roll, Premium Quality, 2-ply Sheets, 200m, Single Packed, 12/ Box - 50 Box Tissue, Interfolded Paper Towel, 1-ply, 100% Virgin Pulp, 150 Pulls Per Pack Min., White - 20 Pieces Toilet Bowl Brush, Any Color, Medium Duty, Rigid, Plastic, 14" Height - 50 Packs Toilet Tissue Paper, 2-plys, 100% Recycled, 12's, White - 20 Pieces Trash Bin With Cover, 22 Liters - 240 Packs Trashbag, Gpp Specs, Black, Xxxl, 10's/ Pack Office Ict Supplies - 5 Pieces Calculator, Compact, 12-digit Desktop Basic Calculator, Solar Battery Dual Power With Large Lcd Display And Large Buttons, Heavy Duty, Genuine - 5 Pieces External Hard Drive, 1tb, Genuine - 25 Pieces Flashdrive, 32 Gb, Genuine - 1 Piece Hdmi Cable, 10 Meters - 5 Pieces Mouse, Wired, Usb Optical, Genuine - 5 Pieces Power Supply Unit, 600 Watts, True-rated - Delivery Period: 1st Tranche – January 2025 And 2nd Tranche – April 2025 - Delivery Site: Da Rfo Xii, Regional Center, Brgy. Carpenter Hill, Koronadal City Cost Of Bidding Documents: P5,000.00 1. During Buying Of Bidding Document: Must Submit Letter Of Intent (loi) And Present The Following Eligibility Document: A. Certificate Of Registration From Philgeps (platinum Membership) B. Registration Certificate From Sec/dti/cda C. Mayor/business Permit D. Tax Clearance 2. In Case Of Representative: Must Submit A Copy Of Board Resolution Or Secretary’s Certificate/special Power Of Attorney Whichever Is Applicable Coupled With Specimen Signature.
Closing Date16 Dec 2024
Tender AmountPHP 1.6 Million (USD 28.7 K)

DEPT OF THE ARMY USA Tender

Consultancy Services
United States
Details: Naics Code 334511 - Search, Detection, Navigation, Guidance, Aeronautical, And Nautical System And Instrument Manufacturing request For Information: This Is Not A Solicitation: This Request For Information (rfi) Will Be Utilized In Planning For The Assured Positioning, Navigation And Timing/space Cross-functional Team (apnt/s Cft), Contested Environment Event. This Rfi Does Not Constitute An Invitation For Bids (ifb), A Request For Proposal (rfp), Or A Request For Quote (rfq), Nor Does Its Issuance Obligate Or Restrict The Government To An Eventual Acquisition Approach. This Rfi Does Not Obligate The Government To Issue A Solicitation. This Rfi Is Being Conducted Solely For Information And Planning Purposes And Does Not Constitute A Solicitation. Neither Unsolicited Proposals Nor Any Other Kinds Of Offers Will Be Considered In Response To This Request Or Accepted By The Government To Form A Binding Contract. No Solicitation Document Exists, And A Formal Solicitation May Or May Not Be Issued By The Government As A Result Of The Responses To This Rfi. The Government Will Not Be Liable For Payment Of Any Response Preparation Expenses And Is Not Obligated By The Information Received. Any Costs Incurred By Interested Companies In Response To This Announcement Will Not Be Reimbursed. The Information Provided May Be Used By The Army In Developing Future Acquisition Strategies And Will Be Used To Identify Capable Sources To Participate In The Event. Interested Parties Are Responsible For Adequately Marking Proprietary Or Competition Sensitive Information Contained In Their Response. note: The Use Of Rfi Number Apntscft-24 Is For Tracking Purposes Only. background/description: In Accordance With Federal Acquisition Regulation (far) Part 10, The Apnt/s Cft Is Conducting Market Research To Identify Potential Sources Capable Of Providing Commercial Off-the-shelf (cots), Non-developmental Items (ndi), Or Near Ndi For Assured Pnt Technologies In The Ground, Air, Space Or Cyber Domains And Situational Awareness, Defensive, And Offensive Capabilities In The Navigation Warfare (navwar) Mission Area. More Specifically, This Rfi Is Being Issued For The Purpose Of Identifying Potential Sources Who Can Provide Ground, Air, Space Or Cyber-based Pnt And Navwar Sensor Capabilities Ready For Test And Demonstration At The Apnt/s Cft Event Or Deployment, Up To 180 Days. this Rfi Requests Respondents To Submit A White Paper That Addresses The Information Outlined Below. In Addition, Respondents Are Encouraged To Submit Corporate Overview Information And Basic Qualifications In Managing Hardware And Software Development Projects That Are Similar In Scope And Process To An Assured Pnt, Electronic Warfare (ew) Or Satellite Communications (satcom) Program. this Rfi Is Part Of A Series Of Industry Engagements In Support Of Enhancing The Industry-government Partnership, Which Is Critical To Providing An Effective And Scalable End-product For Apnt, Space-based Pnt Navwar And Other Capabilities. The Government Intends To Consider All Industry Inputs And Initiatives. The Army Plans To Leverage Industry Recommendations On The Delivery Of Assured Pnt, Non-space And Space-based Pnt And Navwar Hardware And Software To Implement Best Practices, Improve Productivity, Gain Programmatic And Operational Efficiencies, And Realize Cost Savings. the Government Will Not Be Responsible For Any Costs Incurred By Event Participants, To Include White Paper Submission Costs, Travel Costs, Technology Demonstrations, Exercises, Experiments, And Any And All Costs Associated With Event Participation. All Costs Incurred Throughout The Event Are The Responsibility Of The Participating Organization. department Of Defense (dod) Science Engineering And Technical Assistance (seta) Contractors And Federally Funded Research And Development Centers (ffrdcs) Supporting Dod Functions May Be Utilized To Review White Paper Submissions, Facilitate The Event And May Participate In Technical Or Operational Assessments. the Government Is Seeking The Following Information In White Paper Responses Provided: what Is The Technology Readiness Level (trl) And Manufacturing Readiness Level (mrl) Of The System Or Capability? If Not Trl 6 Can A Trl 6 Or Greater Be Achieved Within A Year Of Assessment? is The Capability Ready For Experimentation Or Demonstration? is The System A Prototype Or Productized Capability? can The System Or Capability Be Provided For Further Soldier/unit Assessment In A Devops (test-fix-test) Environment? on What Platforms Will The Capability Integrate – Mounted, Dismounted, Aerial, Fixed Site, On-orbit, Ride-share, Free Flyer, Etc.? what Army Warfighting Function Will The Capability Support – E.g. Aviation, Fires, Maneuver, Intelligence, Cyber, Sustainment, Mission Command is The System Or Capability A Non-space-based Solution? Can It Become A Non-space-based Pnt Solution? what Is The Minimum And Maximum Global Navigation Satellite System (gnss) Spectrum Range And Rate The System Or Capability Can Detect A Signal Of Interest? what Is The Field Of Regard Of The Sensor Or Antenna (area Covered For The Detector Of The System When Pointing To All Mechanically Possible Positions)? Can It Be Sectored? what Is The Instantaneous Field Of View Of The Sensor Or Antenna (area Covered For The Detector Of The System When Pointing To One Position)? over What External Interfaces Does The Capability Provide Data? Describe The Output File Formats, Bandwidth Requirements And Indicate Any That Are Not Among Recognized Standards. can The Capability Be Operated Remotely? If So What Is The Mechanism? Can You Describe The Interface In Detail Or Provide An Interface Control Document? what Are The Size, Weight And Power (swap) Characteristics Of The Capability? what Is The Required Clearance Volume Of The Antenna? How Is It Oriented With Respect To Potential Mounting Locations? what Global Positioning System (gps) Receiver Does Your System Use? If There Is A Built-in Gps Is It Selective Availability Anti-spoofing Module (saasm) Compliant? Can The System Interface To A Gps That Is Saasm Compliant? is The System Or Capability Military Code (m-code) Compatible? can The System Or Capability Be Ruggedized And Capable Of Extended Operation In Multiple Worldwide Outdoor Environments? What Military Standard (mil Std) Is The System Built To Or Tested To? provide Documentation Of Ansi 95.1 (2005) Compliant Stand-off Distance While Operating. will The System Or Capability Support Aerial And Ground-based Assured Pnt And/or Anti-jam (aj) Antenna Capabilities? will The System Or Capability Support Spectrum Monitoring, Detection And Tracking Of And/or Data Analytics For Signals Of Interest Within The Gnss Spectrum? If So, Identify Which Gnss Signals? describe Any Specialized Software That Is Required For System Operation. If Such Software Is Required, Provide Information On The Operating System Environment, Minimal Hardware Requirements And Architecture (processor Type, Performance, Etc.) Required To Run The Software. what Software Licensing Agreements Are Available For Government Purchase? what Is The Typical First Article Delivery Time And Typical Production Rate Of The System? what Detailed Technical Data Package For The System Or Capability Is Available To The Government, Either As Part Of A Unit Purchase Or Through A Separate Agreement, Including Cable Drawings? what Data Rights Are Available To The Government As Part Of A Purchase? what Integration Information (mechanical, Electrical) Is Immediately Available And Releasable To The Government? Is An Initial Capability Document (icd) Available Allowing The Government To Interface Directly With The Sensor Software Or To System Middleware? does The System Require A Specialized Skill Set Or Military Occupational Specialty (mos) To Operate And Maintain The System? does The System Support Victory And Open System Architecture (osa) Requirements? describe The Available Operator Training Curricula. describe Any Established Training For Maintenance. what Sustainment And Training Requirements Can The Contractor Support? what Platforms/systems Is The Capability Already Integrated Onto? for Geolocation Capabilities What Is The Expected Accuracy And Precision For Spectrum Monitoring? what Is The Expected Timeline For Delivery Of Spectrum Monitoring Information? Does It Support Tactical Timelines? are Projected Capabilities Compatible With Army Systems? what Cyber Security Standard Is Your System Or Capability Compliant With And Who Sanctioned It? what Cyber Security Software Analysis Tools Have Been Utilized To Examine The System Or Capability And What Are The Results Of Those Examinations? what Are The Training Requirements Needed For Unit Leaders And Staffs To Incorporate The System Properly Into Planning And Execution Of Operations? describe Embedded Built In Test (bit)/built In Test Equipment (bite) Capability Available With The System And To What Level It Reports Faults. what Critical Program Information Protections Are In Place? what Reliability, Availability, And Maintainability (ram) Performance Does Your System Meet, To Include Expected Mean Time Between Failure (mtbf)? what Warranty Coverage Is Available And Explain Any Extended Maintenance Support. describe The Transportation And Storage Requirements. has Your Company Performed This Type Of Effort Or Similar Type Effort (to Include Size And Complexity) In The Past? If So, Provide Contract Number, Point Of Contact (poc), E-mail Address, Phone Number, And A Brief Description Of Your Direct Support Of The Effort. what Radio Frequency (rf) Is Optimum To Have Your System Tested Against? companies Should Provide Data To Support Performance Claims Either By Analysis Or With Test Data. in Addition To The White Paper, All Interested Parties Are Encouraged To Submit Company And Product Literature, And/or Other Pertinent Information, Such As A Description With Performance Parameters And A Statement Of Current Availability, Summary Of Prior Testing, Test Reports, And An Estimated Cost Of Test Articles And Production Units, For The Government’s Consideration. Interested Parties Are Encouraged To Provide A Current Customer Base And Identify Systems In Which The Product Is Currently Being Employed. responding To This Rfi: Interested And Capable Sources Are Invited To Submit An Unclassified White Paper Describing Their System. Please Limit White Paper Submissions To A Maximum Of Fifteen (15) Pages (including A Cover Sheet) And Provide The Following Information: cover Sheet contact And Company Information name title company Name date Of Incorporation number Of Years In Business number Of Employees company Security Clearance Level location mailing Address phone Number website Address email Address note That Rfi Respondents Shall Designate A Single Point Of Contact For Receipt Of All Information Pursuant To This Rfi. please Identify Your Company's Small Business Size Standard Based On The Primary North American Industrial Classification System (naics) Code Of 334511- Search, Detection, Navigation, Guidance, Aeronautical, And Nautical System And Instrument Manufacturing. The Small Business Size Standard For This Naics Code Is 1,250 Employees. For More Information, Please Refer To Http://www.sba.gov/content/table-small-business-size-standards. Please Also Indicate Any Socioeconomic Classifications: large Business Concern; small Business (sb) Concern; 8(a); small Disadvantaged Business (sdb); women-owned Small Business; historically Underutilized Business Zone (hubzone); veteran-owned Small Business; service-disabled Veteran-owned Small Business name/type Of Technology Or Model technology Maturity: Existing Technology Or Technology Concept (reference Questions 1-45 Above) brief Overview Of Company History body Of White Paper: the Submittal Should Address The Requests For Information Above, And Any Additional Technical Or Company Information. A Description Of The System Supported By Technical Parameters Is Desired. the Government Requests That Interested Sources Submit An Electronic Response Of Not More Than Fifteen (15) Pages, 8.5" X 11" Paper, 12-point Times New Roman Font, With A Minimum Of One (1) Inch Margins All Around. Responses Should Include The Following Point Of Contact Information: • Company Name • Duns # • Cage Code • Address • Point Of Contact • Phone Number • Fax Number • Email Address supporting Documentation (such As Marketing Brochures, Fliers, Published Presentations Or Papers And Other Materials That Summarize The Technology And More About Your Company) Is Acceptable (up To 2 Pages Worth), And May Be Referenced By Reviewers Only In Support Of Claims Identified In The White Paper, And Only Where Specifically Referenced In The White Paper. The Government Makes No Guarantee That The Supporting Documentation Will Be Reviewed And/or Considered. any Company Proprietary Information, Performance Capabilities And/or Future Modification Plans Should Be Clearly Identified And Must Be Marked Accordingly And Will Be Protected By The Government. responses To The Rfi Will Not Be Returned. responses To The Rfi May Be Used To Develop Government Documentation. responses To The Rfi Will Be Used For Planning Purposes To Identify Interested Sources Capable Of Participating In The Event. respondents To The Rfi May Not Receive Feedback From The Government Once Reviewed. additional Information May Be Requested And / Or Provided By The Government To Capable Sources In Support Of The Event. proprietary Information Should Be Clearly Marked. No Classified Documents Will Be Included In Your Response. Please Be Advised All Information Submitted In Response To The Rfi Becomes The Property Of The U.s. Government And Will Not Be Returned. All Information Received In Response To This Rfi Marked "proprietary" Will Be Handled Accordingly. as Indicated Above, The Government Will Utilize Non-government Personnel To Review Responses To This Rfi, Plan, Coordinate And Execute The Event. The Respondent Must Clearly State On The Cover Sheet To The Rfi Response Whether Or Not A Proprietary Information Agreement (pia), Non-disclosure Agreement (nda), Or Equivalent Is Required Prior To Non-government Personnel Reviewing The Submissions. Should A Pia/nda Be Required, The Respondent Must Obtain The Pia/nda From The Company Pocs And Provide The Pia/nda With Their Rfi Submittal. To Obtain The Company Poc List, Please Send An Email Request To The Following: Ms. Lisa Reyes Lisa.t.reyes.ctr@army.mil all Interested Companies Or Organizations Are Encouraged To Respond To The Rfi By Providing Information By 3:00 Pm Est On 30 November 2023. respondents Are Requested To Submit An Electronic Copy Of The Responses To The Apnt/s Cft, Integration Division, Test And Experiment Lead, Mr Jason Wideman Jason.b.wideman.civ@army.mil And To The Project Lead, Ms. Lisa Reyes Lisa.t.reyes.ctr@army.mil include Rfi Number Apntscft-24 In The Subject Line. All Requests For Further Information Shall Be In Writing And Via Email; Telephonic Requests For Additional Information Will Not Be Accepted. your Interest In Participating In Our Event Is Appreciated.
Closing Soon30 Nov 2024
Tender AmountRefer Documents 

National Library Of The Philippines Tender

Publishing and Printing
Philippines
Details: Description Invitation To Bid For The Supply And Delivery Of Supplies And Equipment For Preservation And Conservation 1. The National Library Of The Philippines (nlp), Through The Fy 2024 General Appropriations Act Intends To Apply The Sum Of Two Million Three Hundred Twenty Eight Thousand Seven Hundred Thirty Five Pesos (php2,328,735.00) Being The Abc To Payments Under The Contract For Pb24-33 Supply And Delivery Of Supplies And Equipment For Preservation And Conservation. Bidding Will Be Through Lot Bidding. Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. Project Description Abc Cost Of Bidding Docs Bid Opening Venue Supply And Delivery Of Supplies And Equipment For Preservation And Conservation (php2,328,735.00) Php2,328,735.00 Php5,000.00 December 18, 2024; 03:01 Pm 3rd Flr Office Area, Nlp Bldg, T.m. Kalaw St. Ermita, Manila 2. The National Library Of The Philippines (nlp), Now Invites Bids For The Above Procurement Project. Delivery Of The Goods Is Required Within One Hundred Twenty (120) Calendar Days. Bidders Should Have Completed, Within Five (5) Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii. Instructions To Bidders. 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. A.bidding Is Restricted To Filipino Citizens/sole Proprietorship, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra 5183. 4. Prospective Bidders May Obtain Further Information From Nlp Bids And Awards Committee (bac) Secretariat Email Address And Inspect The Bidding Documents Posted At The Philippine Government Electronic Procurement System (philgeps) Or In Our Official Website Web.nlp.gov.ph. 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On November 27, 2024 Through Email And Website(s) Below. The Procuring Entity Shall Allow The Bidder To Present Its Proof Of Payment For The Fees Through Electronic Means Or By Presenting The Official Receipt In Person. 6. The Nlp Will Hold A Pre-bid Conference On December 05, 2024 At 09:00am Through Video Conferencing Via Zoom Which Shall Be Open To All Prospective Bidders. Send Interest To Bac@nlp.gov.ph With Subject: Request To Join The Pre-bid Conference Of Public Bidding No. 24-33. 7. Bids Must Be Duly Received By The Bac Secretariat Through Manual Submission At The Office Address Below On Or Before December 18, 2024 At 03:00 Pm. A Usb Flash Drive Containing The Soft Copy Of The Technical (in Pdf) And Financial (in Word Or Excel) Requirements Must Be Included In The Original Copy Of The Technical Documents. Late Bids Shall Not Be Accepted. 8. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 14. 9. Bid Opening Shall Be On December 18, 2024 At 03:01 Pm At The 3rd Floor Office Area, Nlp Building. Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend The Activity. 10. The Nlp Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections 35.6 And 41 Of The 2016 Revised Irr Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 11. For Further Information, Please Refer To: Maureen M. Terrenal Marie Joy H. Bestoir Eleanor C. Siyang Jonathan F. Santos Bac Secretariat National Library Of The Philippines Tel. No.: (02) 5314-2100loc. 406 / 412 Email: Bac@nlp.gov.ph Website: Web.nlp.gov.ph 12. You May Visit The Following Websites: For Downloading Of Bidding Document: Web.nlp.gov.ph / Www.philgeps.gov.ph Sgd. Maricel M. Ureña Bac, Chairperson 1. Uv Meter (1 Pc) The Meters Measure The Proportion Of Uv Present (μw/lumen), The Total Amount Of Uv (μw/m2) And The Amount Of Visible Light Present (lux). The Amount Of Uv Should Be As Little As Possible And In General Should Not Exceed 20μw/m2 Or 75μw/lumen. Normal Museum Light Levels Should Be Limited To 150-250 Lux. Once Measurements Have Been Observed Action Can Be Taken, Light Levels Altered, If Necessary Uv Filters Fitted To Display Cases, Windows And Fluorescent Tubes. The Uv Light Meter (952-7650) Will Measure Uv Present (μm/lumen), The Amount Of Uv (μm/m2) And The Amount Of Visible Light Present (lux Or Foot-candles). 2. Deacidification Spray (4 Bottles) ● Safely Neutralizes Acids And Extends The Lifespan Of Paper At Least 3 To 5 Times Longer Than Un-treated Material. ● Buffering Agent Is Evenly Distributed Throughout A Sheet Of Paper ● No Effect On The Integrity Of The Inks ● Does Not Damage Adhesive Or Binding Fabrics. ● Non-toxic, Non-hazardous, Contains No Cfc’s And No Solvents. ● The Products Are Non-clogging, Virtually Odor-free And Dry In Minutes. 3. Silica Gel (10 Packs) ● Prevent Rust, Corrosion, Mold And Mildew In Closed Containers. ● Size: 3 Grams Per Pc. / 4 Pc. Per Pack 4. Tacking Iron (1 Pc) 230 Voltage program The Tip Size Reference, Enabling The Led Temperature Readout To Display Accurate Temperature 30ºc - 200ºc (+/- 5ºc), Whatever The Size Of The Tip includes 1 X 805-2405 Standard Tip 5. Digital Microscope (1 Pc) Digital Microscope With Long Working Distance, Handheld Design For Portability, Featuring 10x-140x Magnification Power. Ideal For Non-destructive Analysis, Highly Precise Cleaning, Characterization Tests And Condition Recording From A Distance Of 40mm-150mm. The Long Working Distance Is The Right Choice When Working On High Glare Materials Such As Metals And Plastics, And To Allow Space For Working On An Object While Viewing Through The Microscope. Comes With Interchangeable Caps For Protection From Dust And Liquids, Alternative Lighting And Magnification, Plus A Precision Calibration Target. *additional Caps Allow Further Flexibility In Use, I.e. Sealed Caps For Dusty Environments Or Protection From Liquids *amr (automatic Magnification Reading) Shows Clearly The Level Of Magnification Through The Software (windows Only) *1.3 Megapixel Sensor Providing 1280x1024 Pixel Resolution, Capture Video (30fps) And Still Images * 10x-140x Magnification *polarizer Filter Allows You To Reduce Or Eliminate Glare On Reflective Surfaces And Also Can Provide The Ability To See Through The Surface Of Fully Or Partially Transparent Materials, Such As Textiles, Paint, Glass, And Plastic. *complete With Software (windows And Mac Compatible) And All Necessary Cables, Simple Usb 2.0 Setup *annotate And Measure Images To 0.001mm *abs Plastic Body With Simple To Operate Dials For Focus And Polarisation *8 (white) Led Illumination Which Can Be Switched On Or Off, Etc. * Provides User Manual 6. Laminar Flow (book Cleaning Machine) (1 Pc) The Workstation’s Work Surface Is Accessible By A Pair Of Protective Gloves And Sleeves With Which You Can Handle Volumes. The Workstation Allows For Dust Cleaning Of Objects In A Sealed Chamber. Dusting Can Be Done Using Different Techniques Depending On The State Of Repair Of The Volumes, Binding Type Or Dust Quantity. Books In A Good Conservation State Can Be Blown With A Manually Controlled Air Flow. Volumes In A More Fragile State Can Be Cleaned Using Soft Bristled Brushes. With Hepa Vacuum Included. * Provides User Manual
Closing Date18 Dec 2024
Tender AmountPHP 2.3 Million (USD 39.4 K)

Autobahnen Und Schnellstra En AG Tender

Austria
Details: The Traffic Control Systems (vba) In Tyrol Extend Over The A12 Inntal Autobahn And A13 Brenner Autobahn. Selected Locations Need To Be Renovated And New Display Cross-sections Need To Be Built. The Services Include The System Technology On The Display Cross Sections, Which Consists Of Dynamic Displays, Environmental Sensors, Traffic Detectors, Video Cameras, Distributors And The Associated Infrastructure. In Addition To The Electrical Engineering Measures, Structural Engineering Measures Are Also Necessary For The Construction Of New Locations. This Includes The Construction Of Steel Structures, Cable Routes And Shafts As Well As Foundations, For Display Cross-sections And Cantilever Arms. Publication Of The Construction Tender Is Planned For Q1/2024.
Closing Date19 Jan 2025
Tender AmountEUR 7.2 Million (USD 7.5 Million)

Don Emilio Del Valle Memorial Hospital Tender

Civil And Construction...+1Building Construction
Philippines
Details: Description Subject : Design And Build Of Dedvmh Multi-purpose / Evacuation Area Location : Dedvmh Compound, Bood, Ubay, Bohol Terms Of Reference I. Background Don Emilio Del Valle Memorial Hospital (dedvmh) Is A Licensed Level 2 General Hospital Located In Ubay, Bohol With 200 Authorized Bed Capacity Which Aims To Provide Highly Specialized Quality Healthcare Services To All Where Human Dignity Is Valued And Respected By Competent And Committed Personnel. In Accordance With The Provisions Of And Related Issuances Of Doh Administrative Order No. 2019-0056 Increasing The Bed Capacity Of Dedvmh From 50 Beds To 300 Beds And R.a. No. 11223, Or The “universal Health Care Act”, The Hospital Shall Provide Promotive, Preventive, Diagnostic, Curative, And Palliative Care Services, And Research, Professional Teaching And Training Programs And Shall Be Fully Equipped With The State-of-the Art Equipment And Facilities, Complemented By Adequately Trained And Competent Human Resources For Health Appropriate For A Licensed And Accredited Tertiary General Hospital. Dedvmh Shall Strengthen Its Existing Basic Services, And Aim For The Improvement Of Its Service Capability And Capacity Serving As Referral Hospital In The Northeastern Section Of The Bohol Province, Complementing Local Health Systems And Providers Of Municipalities In The Area. In Order To Fulfill This Mandate, Dedvmh Is Upgrading Its Services To Become A Level Iii Hospital To Provide Better And Quality Healthcare Services Especially In The Northeastern Part Of Bohol, Its Catchment Areas And Nearby Provinces. The Increase In The Bed Capacity And Expansion Of Services And Capability Are Consistent With The Dedvmh’s Hospital Development Plan (hdp) And Philippine Health Facility Development Plan (phfdp) 2020-2040. Ii. Objectives This Project Aims To Construct A Safe Center While Providing Prime Patient Care During Weather Adversities. This Is In Consonance As Well With Our Continuing Drive In Developing Health Measures To Adapt To Climate Change. This Center Shall Serve As A Safe Sport Avenue Promoting Healthy Lifestyles To Healthcare Workers. This Will Also Be Utilized To House Hospital Activities To Shield Participants From Heat And Rain. It Also Aims To Create A Versatile Multi-purpose/evacuation Center Housing The Health Information Management Systems (himo) Department On The Lower Ground Floor To Support Secure And Efficient Data Management Critical To Hospital Operations. With Future Funding, The Center Is Planned To Include A Multi-purpose Court On The Upper Ground Floor, Promoting Wellness And Recreational Activities For Healthcare Staff, As Well As Office Spaces On The Second Floor To Support Future Departmental Growth And Administrative Needs, Ensuring The Facility Remains Adaptable And Functional For Various Purposes. The Design Must Also Conform To The Standards Set By In Accordance To The Manual On Technical Guidelines For Hospitals Planning And Design (level 3) And Doh Green And Safe Health Facilities Manual To Develop Climate Smart Health Facilities That Address And Adapt To The Impacts On The Environment. The Winning Bidder Shall Design For This Project With The Approval Of The Medical Center Including The Approved Detailed Estimates, Bill Of Quantities, Technical Specifications, And Methodology Of Construction And Scope Of Works Of The Project. Iii. Conceptual Design The Design Concept Of The Project Was Governed By The Planning And Design Standards Of Level 3 Service Capability Hospital Facility As Prescribed By The Latest Requirements Of The Department Of Health And Other Concerned Agencies. Building Design Shall Conform To The Provisions Of The National Building Code Of The Philippines (pd 1096), Accessibility Law (bp 344), Architecture Law (ra 9266), National Structural Code Of The Philippines, Electrical Engineering Law (ra 7920), Mechanical Engineering Law (ra 5336), Plumbing Code (ra 1378, 1993-1994 Revisions), Fire Code (ra 9514) And Other Laws And Regulations Covering Environmental Concerns And Local Ordinances And Regulations. The As-built Plan And Proposed Schematic Lay-out/call-out Will Be Provided As Basis Reference In The Development Of Preliminary Conceptual Design Plans To Be Submitted As Part Of The Technical Proposal. However, It Is The Responsibility Of The Bidder To Verify Actual Site Conditions And Dimensions. The Preliminary Conceptual Design Plans And Perspectives Shall Be Included Construed Part Of The Technical Proposal As Follows: Preliminary Conceptual Design Plans Required Specified Degree Of Details 1. Schematic Floor Plans: A. Lower Ground Floor B. Upper Ground Floor (partitions For Funding) C. Second Floor (above Stage Area) All Schematic Plans Shall Be At Least A3 Size Paper And Shall Meet The Minimum Space Requirements And Planning/design Guidelines Of Level 3 Hospital For: - Health Information Management Systems Department Offices & Storage, Waiting Area - Wellness Area - Covered Area Proposed For Multi-purpose Court - Proposed Area For Offices Preliminary Conceptual Design Plans Required Specified Degree Of Details A. Aerial Perspective View All Perspective / Plans Shall Be At Least A3 Size Paper In Colored Printed And Shall Conform With The Preliminary Conceptual Plans And At Least 3d Rendered. B. Man’s Eye / Worm’s Eye Perspective View All Perspective / Plans Shall Be At Least A3 Size Paper In Colored Printed And Shall Conform With The Preliminary Conceptual Plans And At Least 3d Rendered. C. Front Perspective View All Perspective / Plans Shall Be At Least A3 Size Paper In Colored Printed And Shall Conform With The Preliminary Conceptual Plans And At Least 3d Rendered. D. Rear Perspective View In Conformance With The Preliminary Conceptual Plans And At Least 3d Rendered. E. Left & Right-side Perspective View All Perspective / Plans Shall Be At Least A3 Size Paper In Colored Printed And Shall Conform With The Preliminary Conceptual Plans And At Least 3d Rendered F. Longitudinal And Transverse Section Plans At Least One Longitudinal And One Transverse Section Plans In At Least A3 Size Paper The Conceptualization Of The Design Including Its Specifications And Space Requirements Shall Complement And/or Supplement With The Existing Site Conditions. Proponent’s Input, Suggestion And Recommendations With Regard To The Identification Of The Scope Or Physical Components And Structures, Specific Outputs And Requirements And Proposed Construction Methods Shall Be Considered. Iv. Performance Specifications And Parameters Site And Space Planning Were Governed By The Standards, Rules And Regulations On The Design Of Level 3 Hospitals As Prescribed By The Department Of Health And Other Concerned Agencies. Building Design Shall Conform To The Provisions Of The National Building Code Of The Philippines (pd 1096), Accessibility Law (bp 344), Architectural Law (ra 9266), Civil Engineering Law (ra 544), National Structural Code Of The Philippines, Electrical Engineering Law (ra 7920), Mechanical Engineering Law (ra5336), Plumbing Code (ra 1378, 1993-1994 Revisions), Fire Code (ra 9514) And Other Laws And Regulations Covering Environmental Concerns And Local Ordinances And Regulations. A. Pre-detailed Design 1. Engineering Surveys And Investigations 1.1 Surveys And Investigations Of The Site Includes Elevations And Contours (at 0.5m Interval), Soil Tests, Location, Dimension, Floor Elevations And Other Pertinent Data On Existing Buildings And Improvements (roads, Parking Areas, Mature Trees) And Existing Utility Lines (e.g. Water, Power, Telephone). 2. Preliminary Conceptual Design Plans/perspective 2.1 Preparation Of The Following Drawings For Design Development Based On The As Built Plan And Schematic Lay-out/call-out Prepared By The Procuring Entity. Please Refer To Section Iii. Conceptual Design. B. Detailed Design Preparation Of Final Design Concept And Detailed Architecture And Engineering Design Shall Be In Accordance With The Schematic Plans For Hospital Building And Design Conceptualization Duly Approved By The Dedvmh. In Determining The Final Design Concept And Detailed Architecture And Engineering Design, The Implementing Unit Together With The Design And Build Contractor Shall Initiate The Coordination Meeting With The Concerned Stakeholders In The Following Schedule: First Session - The Design And Build Contractor Shall Present The First Schematic Plan And Design Concept For Deliberation, Consultation And Inputs By The Proponents Within Ten (10) Calendar Days From The Effectivity Of Notice To Proceed Second Session - The Design And Build Contractor Shall Present The First Revision Of Schematic Plan And Design Concept For Deliberation, Consultation And Inputs By The Proponents, If There Any, Within Twenty (20) Calendar Days From The Effectivity Of Notice To Proceed Third Session - The Design And Build Contractor Shall Present The Second Revision Of Schematic Plan And Design Concept For Deliberation, Consultation And Inputs By The Proponents, If There Any, Within Thirty (30) Calendar Days From The Effectivity Of Notice To Proceed Upon Approval Of The Final Schematic Plan And Design Concept, The Design And Build Contractor Shall Then Proceed For The Design Phase, Enumerated As Follows: 1. Preparation Of The Following Detailed Design Drawings Of Entire Building (see Doh Checklist Of Drawings Requirements) Based On The Design Development Drawings And Design Parameters Including Any Revisions And Refinements As Approved And Required By The Dedvmh: A. Detailed Architectural Plans (refer To Checklist Of Drawings Requirements And Design Parameters). B. Detailed Structural Plans (refer To Checklist Of Drawings Requirements And Design Parameters). C. Detailed Electrical Plans (refer To Checklist Of Drawings Requirements And Design Parameters). D. Detailed Storm Drain, Sanitary And Plumbing Plans (refer To Checklist Of Drawings Requirements And Design Parameters). E. Detailed Mechanical Plans (refer To Checklist Of Drawings Requirements And Design Parameters). F. Structural Computations, Including Soil Boring Test Results And Seismic Analysis And Electrical Design Computations. G. General Notes And Technical Specifications Describing Type And Quality Of Materials And Equipment To Be Used, Manner Of Construction And The General Conditions Under Which The Project Is To Be Constructed. H. Detailed Cost Estimates, Detailed Bill Of Qualities, Bill Of Quantities, And Program Of Works Including A Summary Sheet Indicating The Unit Prices Of Construction Materials, Labor Rates And Equipment Rentals. I. Summary Of Works J. All Design Output Shall Include The Following: Particulars Design Required Output Hard Copy Printed In Standard Size Paper 40 X 30 Printed And Hardbound Catalog For All Perspective Views, Architectural Finishes, Electrical Fixtures, Sanitary/plumbing Fixtures Utilizing Standard A4 Size Photo Paper Electronic Copy Electronic Copies In Standard Formats: - Designplansfile.pdf; - Designplanscadfile.dwg; - Design3dfile.skp/dwg/etc; - Powerpointpresentation.ppt; - 3d Animations (walkthrough.mp4/avi/mov/etc.) Design And Build Contractor Shall Compile All The Files And To Be Stored In 1tb External Drive Fourth And Final Session - The Design And Build Contractor Shall Submit The Completed Detailed Design Drawings Of The Entire Building, Within Sixty (60) Calendar Days From The Effectivity Of Notice To Proceed. C. Green Building 1. Design Development Shall Consider At Least Basic Requirements For Green Building Applied To Hospital Facilities In Building Component Systems Such As Architectural, Structural, Electrical, Mechanical, And Sanitary. D. 3d Animation And Walkthrough Presentations Designer Shall Prepare A 3d Walkthrough, That Is, Taking A Virtual Tour Of The Proposed Project/structure In Any Design Platform. It Shall Be Produced From Digital 3d Models That Have Been Visualized To A Photo-realistic Standard That Will Showcase All The Design Elements, Both Externally And Internally Of A Property Development And Its Spaces. Minimum Expected Output Shall Include But Not Limited To: - 3d Walkthrough Presentation That Will Show From The Main Entrance Of The Hospital Compound, Going Through The Site Where The Project Is To Be Located. From The Site, It Should Walk Through The Main Facade And Entrance Of The Ground Floor Of The Building Up To The Third Floor Showing All The Respective Floors, Its Lobbies, Hallways, Rooms And Other Support Facilities. - In Addition, The 3d Walkthrough Presentation Shall Include The Exterior Views / Facade Of The Building With Its Adjoining Structures. E. Pre-construction Pre-construction Meeting Shall Be Scheduled On The Next Day That The Completed Detailed Design Drawings Are Submitted. Key Stakeholders—including The Dedvmh, And The Design And Build Contractor (architects, Engineers, Consultants, And Contractor—must Attend). The Meeting Will Serve To:  Review And Confirm The Submitted Design Documents.  Ensure That The Designs Comply With The Project’s Specifications, Budget, And Schedule.  Address Any Necessary Adjustments Or Clarifications Before Construction Commences. After The Pre-construction Meeting, The Design And Build Contractor Shall Finalize And Submit The Following Documents For The Approval Of Dedvmh: 1. Duly Signed Construction Schedule And S-curve 2. Duly Signed Manpower Schedule 3. Duly Signed Construction Methods 4. Duly Signed Pert Cpm And Ghannt Chart Showing Per Item Of Works Of Individual Projects 5. Log Book This Submission Should Encompass All Architectural, Structural, And Mepfs Plans, Specifications, And Any Amendments From The Meeting. These Documents Will Form The Basis For Construction. Upon The Dedvmh’s Approval Of The Submitted Construction Documents, A Notice To Commence Will Be Issued. Construction Activities May Only Begin Following The Issuance Of This Notice. F. Construction As A Rule, Contract Implementation Guidelines For Procurement Of Infrastructure Projects Shall Comply With Annex “e” And Guidelines For The Implementation Of Contracts For Design And Build Infrastructure Projects Shall Comply With Annex “g” Of Irr, Ra 9184. The Following Provisions Shall Supplement These Procedures: 1. Scope Of Works: Supply Of Materials, Labor, Tools And Equipment Necessary To Complete The Execution Of Architectural, Structural And Electrical And Mechanical Works. Includes All Other Necessary Works That Complete For The Fully Operational Building But Limited To The Following Work Items; A) Site Works - Provision Of Temporary Perimeter Fence - Demolition Of Existing Building/structure, Includes Hauling Of Debris Within The Hospital Compound - All Materials, Debris, Etc. Identified As Garbage As Directed By Hospital Management Shall Be Disposed Off-site - Excavation And Grading Provide Necessary Soil Protection On Excavated Portion. - Soil Poisoning And Termite Control B) Foundation Works - Foundation Of The Entire Building Includes Column Footings, Wall Footings And Other Sub-structures As Specified In The Approved Plan. C) Concrete Works - From Foundation (entire Building); Includes Slabs, Beams And Girders D) Architectural Works I) Exterior Walls – All Exterior Wall At Lower Ground Floor To Upper Ground Floor Including Plastering Ii) Interior Walls – All Interior Wall At Functional Floors Complete With Wall Finishes Iii) Ceiling Works – All Functional Floors As Determined By Procuring Entity Iv) Floor Finish – All Functional Floors As Determined By Procuring Entity V) Doors And Windows– All Exterior Doors And Windows As Per Plan And Specifications Vi) Doors And Windows – All Functional Areas As Determined By Procuring Entity Vii) Painting Works – All Exterior Walls; Interior Walls At Functional Areas Viii) Façade And Signage E) Electrical Works I) Roughing-ins – All Necessary Roughing-ins Including Riser Conduits From Lower Ground Floor To Upper Ground Floor Including Cable Tray Ii) Panel Boards And Breakers – Main Breaker; Panel Boards From Ground Floor To Third Floor Iii) Wires And Cables – All Wires And Cables At Functional Floors Includes Installation Of Main Feeder Lines Tap To Existing Power House Including Connections To All Panel Board And Breakers Iv) Electrical Fixtures And Devices – All Fixtures And Wiring Devices At Functional Areas. Provision Of Usb Ready Outlets To Every Rooms. V) Application Of Electrical Connections/permits Shall Be Shouldered By The Contractor F) Mechanical Works I) Installation Of Automatic Fire Protection System At Functional Areas Ii) Installation Air Condition Units At Functional Areas As Determined By Professional Mechanical Engineer G) Plumbing And Sanitary Works I) Installation Of Plumbing And Sanitary System At Functional Areas, Includes; - Water Supply Pipelines - Waste Water Pipelines - Plumbing Fixtures And Accessories - Necessary Riser Pipes - Fiber Glass Pressure Tank - Drainage System I) Electronics / Auxiliary Works - At Functional Areas: Public Address / Voice Evacuation Systems (paging Systems), Cctv, And Or Integrated Information And Communication Systems, Installation Of Fire Detection And Alarm System (fdas) At Functional Floors J) Other Works 1. No Works Shall Commence Unless The Contractor Has Submitted The Prescribed Documentary Requirements And The Dedvmh Has Given Written Approval. Work Execution Shall Be In Accordance With Reviewed And Approved Documents. The Contractor Shall Process The Approval Of Permit To Construct (ptc) Form Doh – Central Visayas Regional Office, Cebu City. In Addition To, The Contractor Shall Process The All-necessary Permits (i.e., Building Permit, Occupancy Permit And All Prerequisite Permits) Chargeable Against The Project. 2. The Contractor Shall Be Responsible For Obtaining All Necessary Information As To Risks, Contingencies And Other Circumstances Which May Affect The Works And Shall Prepare And Submit All Necessary Documents Specified By The Concerned Building Officials To Meet All Regulatory Approvals As Specified In The Contract Documents. 3. Any Errors, Omissions, Inconsistencies, Inadequacies Or Failure Submitted By The Contractor That Do Not Comply With The Requirements Shall Be Rectified, Resubmitted And Reviewed At The Contractor’s Cost. If The Contractor Wishes To Modify And Design Or Document Which Has Been Previously Submitted, Reviewed And Approved, The Contractor Shall Notify The Hospital Management And The Procuring Entity Within A Reasonable Period Of Time And Shall Shoulder The Cost Of Such Changes. 4. As A Rule, Changes In Design And Construction Requirements Shall Be Limited Only To Those That Have Not Been Anticipated In The Contract Documents Prior To Contract Signing And Approval. The Following Guidelines Shall Govern Approval For Change Or Variation Orders: A. Change Orders Resulting From Design Errors, Omissions Or Non-conformance With The Performance Specifications And Parameters And The Contract Documents By The Contractor Shall Be Implemented By The Contractor At No Additional Cost To The Procuring Entity. B. Provided That The Contractor Suffers Delay And/or Incurs Costs Due To Changes Or Errors In The Dedvmh Performance Specifications And Parameters, The Contractor Shall Be Entitled To Either One Of The Following: 1. An Extension Of Time For Any Such Delays Under Section 10 Of Annex “e” Of Irr (ra 9184); Or 2. Payment For Such Costs As Specified In The Contract Documents, Provided, That The Cumulative Amount Of The Variation Order Does Not Exceed Ten Percent (10%) Of The Original Project Cost. C. The Contract Documents Shall Include The Manner And Schedule Of Payment Specifying The Estimated Contract Amount And Installments In Which The Contract Will Be Paid. D. The Contractor Shall Be Entitled To Advance Payment Subject To The Provisions Of Section 4 Of Annex “e”, Irr (ra 9184). D. The Dedvmh Shall Define The Quality Control Procedures For The Design And Construction In Accordance With The Doh Guidelines And Shall Issue The Proper Certificates Of Acceptance For Sections Of The Works Or Whole Of The Works As Provided For In The Contract Documents. E. The Contractor Shall Provide All Necessary Equipment, Personnel, Instruments, Documents And Others To Carry Out Specified Tests. F. This Design And Build Projects Shall Have A Minimum Defects Liability Period Of One (1) Year After Contract Completion Or As Provided For In The Contract Documents. This Is Without Prejudice To The Liabilities Imposed Upon The Engineer/architect Who Drew Up The Plans And Specification For Building Sanctioned Under Section 1723 Of The New Civil Code Of The Philippines. G. The Contractor Shall Be Held Liable For Design And Structural Defects And/or Failure Of The Completed Project Within The Warranty Period Of 15 Years For Permanent Structures/buildings As Specified In Section 62.2.3.2 Of The Irr (ra 9184) V. Implementation Arrangement A. Reporting Protocol Contact Person I. Nelson A. Elle, Md, Dtmph, Mscih Office Of The Medical Center Chief Ii Don Emilio Del Valle Memorial Hospital Bood, Ubay, Bohol Ii. Joan V. Kadusale, Cpa Supervising Administrative Officer Don Emilio Del Valle Memorial Hospital Bood, Ubay, Bohol Iii. Leomel R. Labitad, Ce Engineer Iii Don Emilio Del Valle Memorial Hospital Bood, Ubay, Bohol Iv. Allana Jane C. Dacoylo, Uap Architect Ii Don Emilio Del Valle Memorial Hospital Bood, Ubay, Bohol Vi. Elegibility Requirements A. Basic 1. The Eligibility Requirements For Design And Build Scheme Shall Comply With The Applicable Provisions Of Sections 23-24 Of Irr Of Ra 9184. 2. A Modified Set Of Requirements Integrating Eligibility Documents And Criteria For Infrastructure Project And Consulting Services Shall Be Adopted In Accordance With Annex G - Guidelines For The Procurement And Implementation Of Contracts For Design And Build Infrastructure Projects Of Irr Of Ra 9184. 3. Pcab Classification Under “general Building”; License Category B “medium A” 4. Contractor Must Have Similar Project In The Amount At Least Fifty Percent (50%) Of The Abc Within The Past Five (5) Years. 5. Similar Projects With The Following But Not Limited To:  Medium-rise Hospital Facility Project, Must Have Ongoing Or Completed Project At Least 6-storey Building.  Supply And Installation Of Hvac System. B. Specialized 1. For Pre-design And Design Phase Of The Contract, The Bidder Shall Comply The Following Professionals To Be Assigned: I. Project Coordinator • Licensed Architect Or Engineer With At Least 15 Years’ Experience In Hospital-related Project Management. • Superb Oral And Written Communication Skills, Organization Skills And Excellent Administrative Abilities. Ii. Architect • The Architect Must Be A Registered And Licensed Architects (rla), With An Updated Professional Identification Card And Must Be A Member In Good Standing Of The Integrated And Accredited Professional Organization Of Architects (iapoa). • Should Have At Least 10 Years’ Experience In Hospital-related Project. Iii. Structural Engineer • Licensed Structural Engineer With At Least 10 Years’ Experience In Hospital-related Project Management. • Must Be A Member Of Accredited Structural Engineer Associations. Iv. Mechanical Engineer • Licensed Professional Mechanical Engineer With At Least 10 Years’ Experience In Hospital-related Project. V. Electrical Engineer • Licensed Professional Electrical Engineer With At Least 10 Years’ Experience In Hospital-related Project. Vi. Sanitary Engineer • Licensed Sanitary Engineer With At Least 10 Years’ Experience In Hospital-related Project. Vii. Cad Operator (at Least One For Architecture And One For Each Engineering Specialty) • At Least Bachelor’s Degree In Architecture, Engineering, And/or Industrial Technology Major In Drafting • Proficient In Autocad Software Viii. Administrative Support Staff 2. For The Construction Phase Of The Contract, The Contractor Shall Assign Technical Personnel With The Following Qualification: I. Project Manager • Licensed Architect Or Engineer With At Least 10 Years’ Experience In Medium Rise Hospital-related Project • Superb Oral And Written Communication Skills, Organization Skills And Excellent Administrative Abilities. Ii. Project Engineer (civil) • Licensed Civil Engineer With At Least 5 Years’ Experience As Project Engineer In Medium Rise Hospital-related Project Iii. Project Engineer (mechanical) • Registered Mechanical Engineer With At Least 5 Years’ Experience As Project Engineer In Medium Rise Hospital-related Project Iv. Project Engineer (electrical) • Registered Electrical Engineer With At Least 5 Years’ Experience As Project Engineer In Medium Rise Hospital-related Project V. Cad Operator (at Least One For Architecture And One For Each Engineering Specialty) • At Least Bachelor’s Degree In Architecture, Engineering, And/or Industrial Technology Major In Drafting • Proficient In Autocad Software Vi. General Foreman (all Discipline) • With At Least 5 Years’ Experience As General Foreman In Medium Rise Project Vii. Skilled Workers (all Discipline) • With At Least 3 Years’ Experience In Medium Rise Project Viii. Administrative Support Staff Vii. Approved Budget Cost Project Description Approved Budget Cost Design Of Dedvmh Multi-purpose / Evacuation Area 5% - 7% Of Abc Construction Of Dedvmh Multi-purpose / Evacuation Area 93% - 95% Of Abc Total Abc Php 30,000,000.00 The Approved Budget For The Design-build Contract Is Thirty Million Pesos (php 30,000,000.00) Which Is Identified As The Design And Build Of Don Emilio Del Valle Memorial Hospital Multi-purpose/evacuation Area. Detailed Architectural And Engineering Design Services Shall Not Exceed Seven Percent (7%) Of The Approved Budget Cost (as Per Prboa Resolution No. 6 Series Of 2016 - Architect’s Guidelines For Standards Of Professional Practice Compliances On The Methods Of Compensation And Schedule Of Fees, Pursuant To Republic Act No.9266, Published In The Official Gazette, September 19, 2016 Issue) Of The Entire Building Inclusive Of Taxes And Duties. Proposals Exceeding The Approved Budget Shall Be Automatically Rejected. Viii. Estimated Duration Of Engagement The Duration Of The Contract Is Three Hundred (300) Calendar Days From The Design Phase Up To The Completion Of The Project From The Date Of Effectivity: I. Pre-design And Design Phase - 60 Calendar Days Ii. Construction Phase - 240 Calendar Days Ix. Minimum Requirements For Construction Safety And Health A. General Requirements No Contractor Or Subcontractor Shall Require Any Employee To Work In Surroundings Or Under Working Conditions That Are Unsanitary, Hazardous, Or Dangerous To His Health Or Safety. In Order To Meet This General Requirement, The Contractor Must: 1. Initiate And Maintain Programs (written Or Otherwise) To Comply With This General Requirement. 2. Provide Frequent And Regular Inspections Of The Job Sites By Competent Persons.  Competent Person Means One Who Is Capable Of Identifying Existing And Predictable Hazards In The Surroundings Or Working Conditions Which Are Unsanitary, Hazardous, Or Dangerous To Employees, And Who Has Authorization To Prompt Corrective Measures To Eliminate Them. 3. Prohibit The Use Of Any Machinery, Tool, Material, Or Equipment That Is Not In Compliance With Applicable Requirements. 4. Permit Only Those Employees Adequately Trained To Operate Machinery Or Equipment. 5. Provide Training For All Employees In:  Recognition And Avoidance Of Unsafe Conditions  Workplace Safety And Health Requirements  Applicable Hazards, Safe Handling, And Personal Protective Equipment Necessary For Handling Poisons, Caustics, Flammables, And Other Harmful Substances Relevant To Their Job Duties.  Specific Hazards And Procedures For Entering Confined Spaces If Applicable 6. Provide Provisions For Medical Care And First Aid. 7. Develop An Effective Fire Protection And Prevention Plan. 8. Ensure Appropriate Housekeeping Measures Including Clear Walkways And Removal Of Combustible Scrap And Debris. 9. Require The Wearing Of Appropriate Personal Protective Equipment Such As Hard Hats, Safety Glasses, Steel Toe Shoes, Or Other Appropriate Protective Equipment In All Operations Where There Is An Exposure To Hazardous Conditions. 10. Develop An Emergency Action Plan Covering Designated Actions Employers And Employees Must Take To Ensure Employees Safety From Fire And Other Emergency.  Plan Must Be In Writing For Employers With Greater Than 10 Employees  All Employees Must Be Trained Upon Initial Assignment On The Parts Of The Plan The Employee Needs To Know In The Event Of An Emergency. 11. Provide Access To Hand Washing Facilities, Toilets, And An Adequate Supply Of Drinking Water. 12. Provide Safety And Health Signs That Are Clearly Visible To Construction Workers And Public. 13. Conduct Regular Safety Meetings. Source: Colorado State University Occupational Health And Safety Section Department Of Environmental Health Fort Collins, Colorado X. Design Technical Specifications And Requirements The Bidder Shall Submit The Following Design Deliverables In Accordance With The Design Specifications, Parameters And Drawing Checklist But Not Limited To The Following: Activity Reports And Documents Required 1. Pre-design Phase 1.1 Structural Analysis And Design Five (5) Sets Duly Signed And Seal Structural Analysis And Design Report In Hard Bound Including The Executable E-files (staad/etabs,etc.) Five (5) Sets Duly Signed And Seal Structural Specifications In Hard Bound (refer To Structural Analysis And Design Specification And Parameters) 1.2 Master Site Development Plans And Conceptual 3d Design Five (5) Sets Duly Signed And Seal Master Site Development Plans In Hard Copy (at Least 20 X 30 Paper Size In Desired Minimum Scale) And Softcopy (editable File.dwg And 3d Model.skp/cad/etc) Powerpoint Presentation And/or Walkthrough Presentation 2. Design Phase 2.1 Detailed Architecture And Engineering Designs/plans Including Applicable And/or Approved Revisions To The Satisfaction Of The Procuring Entity Five (5) Sets Duly Signed And Seal Detailed Architecture And Engineering Plans/drawing In Hard Copy (at Least 20 X 30 Paper Size In Desired Minimum Scale) And Softcopy (editable File.dwg And 3d Model.skp/cad/etc) (refer To Design Parameters And Drawing Checklists) 2.2 Construction Technical Specifications Five (5) Sets Duly Signed And Seal Construction Technical Specifications In Hard Bound Xi. Space Requirements General Floors:  Ceiling Height Should Be At Least Three Meters Clear Height For 2nd Floor And Up. Ground Floor Lobby Must Be Of Higher Ceiling.  Provision Of Utility Room Enough To House Trolley And Dirty Utilities With Floor Drain  All Floors Shall Have Direct Access To Ramp  Both Stairs Are For Service And Emergency Use  External Window At Second Floor And Up Shall Be Of Awning Type.  Provision Of Electrical Room  Ramp For Wheelchair Access (with A Clear Width Of At Least 1.22 M. 4 Ft.).  Minimum Of Two (2) Exits, Remote From Each Other, For Each Floor Of The Building.  Exits Restricted To The Following Types: Door Leading Directly Outside The Building, Interior Stair, Ramp And Exterior Stair.  Exits Terminate Directly At Open Space To The Outside Of The Building. Lower Ground Floor – Health Information Management Systems Department • Waiting Area - This Area Is Dedicated For Waiting Area Of Patients, Patient’s Immediate Family Members, Hospital Staffs, And Client/visitors For Receiving And Issuance Of Medical/medico-legal Certificates, Birth And Death Certificates. It Is Designed As An Open Space To Promote Cross-ventilation, Ensuring Comfort And Improved Air Quality For All Users. - Planning Relationships: A. Accessible To Receiving/releasing Area - Lighting System: B. For General Illumination, Provide At Least 500 Lux. - Power System: C. Provide At Least Four (4) Units Of Outlet With Specifications Of 15a, 2p, 240v, Duplex, Grounding Type And Universal Slots. Also, Provide At Least One (1) Unit Of Outlet For Emergency Light With Specifications Of 15a, 2p, And 240v, Single. - Auxiliary System: D. Provide And Install The Following Auxiliary System: • Communication System  Public Address Paging System – Provide At Least One (1) Unit Paging System - Fire Alarm System: E. Provide At Least Two (2) Units Smoke Detector. - Security System: F. Provide Closed – Circuit Television Cctv Shall Be Installed At The Lobby And Corridor Or Hallway Of This Floor With Central Monitor Located At The Reception Area And At Least Two Views Or Angles Of Cctv • Staff Office And Releasing/receiving Area - This Area Is Dedicated For Hims Staff And Other Authorized Users To Conduct Medical Studies, Read, Write, And Retrieve Records, Processing And Filing Of Opd, Er, And Or Records, Transcription Of Birth And Death Certificates, Staff Assembling/inputting Of Inpatient Charts And Updated Death Registry, And Receiving/issuance Of Medical/medico Legal Certificates, Birth, And Death Certificates. This Shall House Thirty-three (33) To Thirty-nine (39) Staff Desks And Chairs, Cabinet Filing, Adjustable Stool At Receiving/releasing/transaction Counter, Transaction Counter Window, Space For Photocopier, Risograph Machine, And Paper Shredder. This Should Be Designed To Incorporate Windows To Enable Cross-ventilation, Ensuring A Well-ventilated, Fresh-air Environment. In Addition To Being Well-lit And Featuring Two Exits, The Area Should Use Noise-reducing Materials To Maintain A Quiet, Efficient Workspace. - Planning Relationships: A. Accessible To Filing Area - Lighting System: B. For General Illumination, Provide At Least 500 Lux. - Power System: C. Provide At Least Fifteen (15) Units Of Outlet With Specifications Of 15a, 2p, 240v, Duplex, Grounding Type And Universal Slots. Also, Provide At Least One (1) Unit Of Outlet For Emergency Light With Specifications Of 15a, 2p, And 240v, Single. - Auxiliary System: D. Provide And Install The Following Auxiliary System: • Communication System  Telephone System – Provide At Least One (1) Unit Telephone Outlet.  Local Area Network System – Provide At Least One (1) Unit Data Outlet.  Public Address Paging System – Provide At Least One (1) Unit Paging System - Fire Alarm System: E. Provide At Least Four (4) Units Smoke Detector. - Security System: F. Provide Closed – Circuit Television Cctv Shall Be Installed At The Lobby And Corridor Or Hallway Of This Floor With Central Monitor Located At The Reception Area And At Least Two Views Or Angles Of Cctv • Wellness Area - The Wellness Area For Hospital Staffs Will Feature Separate Male And Female Comfort Rooms And Showers, Lockers, Space For Exercise Equipment, A Mirrored Wall, And A Full-length, One-way Tinted Framed Operable Awning Window And A Swing-in Double Entrance Door, That Will Offer A Wide View Of The Hospital Grounds, Providing Natural Light And Cross Ventilation For An Inviting And Refreshing Environment. Main Floor Tiles Should Be Of Vinyl Flooring, Ensuring A Safe, Durable Surface For Exercise Equipment And Activities. This Choice Adds Comfort And Safety To The Space For Staff Use. - Planning Relationships: A. Adjacent To Hims Department Waiting Area - Lighting System: B. For General Illumination, Provide At Least 500 Lux. - Power System: C. Provide At Least Ten (10) Units Of Outlet With Specifications Of 15a, 2p, 240v, Duplex, Grounding Type And Universal Slots. Provide At Least Six (6) Units Floor Mounted Outlet With Specifications Of 15a, 2p, 240v, Duplex, Grounding Type, Universal Slot. Also, Provide At Least One (1) Unit Of Outlet For Emergency Light With Specifications Of 15a, 2p, And 240v, Single. - Auxiliary System: D. Provide And Install The Following Auxiliary System: • Communication System  Telephone System – Provide At Least One (1) Unit Telephone Outlet.  Local Area Network System – Provide At Least One (1) Unit Data Outlet.  Public Address Paging System – Provide At Least One (1) Unit Paging System - Fire Alarm System: E. Provide At Least Two (2) Units Smoke Detector. - Security System: F. Provide Closed – Circuit Television Cctv With At Least Two Views Or Angles. • Head Office With Toilet - This Area Is Where Health Information Management Officer (himo) Reads, Transcribes, And Updates Disease And Operation Coding And Indexing, Prepares Communications And Other Pertinent Papers Related To Medical Records As Requested By Patients, Protects Confidentiality Of Medical Records, Performs Statistical And Other Reports Required By Doh And Other Institutions, And Performs Qualitative And Quantitative Analysis Of Hospital Health Records. This Will Feature A Glass Partition With A Door, Providing Visibility And Privacy Between The Office And The Staff Office And Releasing/receiving Area. It Will Also Include A Comfort Room And A Sofa For Receiving Visitors. - Planning Relationships: A. Accessible To Receiving/releasing Area B. Accessible To Staff Office - Lighting System: C. For General Illumination, Provide At Least 500 Lux. - Power System: D. Provide At Least Five (5) Units Of Outlet With Specifications Of 15a, 2p, 240v, Duplex, Grounding Type And Universal Slots. Provide At Least One (1) Unit Ground Fault Circuit Interrupter Also, Provide At Least One (1) Unit Of Outlet For Emergency Light With Specifications Of 15a, 2p, And 240v, Single. - Auxiliary System: E. Provide And Install The Following Auxiliary System: • Communication System  Telephone System – Provide At Least One (1) Unit Telephone Outlet.  Local Area Network System – Provide At Least One (1) Unit Data Outlet.  Public Address Paging System – Provide At Least One (1) Unit Paging System - Fire Alarm System: F. Provide At Least One (1) Unit Smoke Detector. - Air-conditioning System: G. Provide Air Conditioning System. • Completion Area/conference Room Toilet - This Room/area Is Where Researchers/doctors And Other Authorized Users Discuss And Finalize Pertinent Papers/documents Related To Medical Records As Requested By Patient/relatives. This Space Will Also Function As A Conference Room, Designed With Soundproofing Materials And A Glass Fixed Window Directly Facing The Staff Office To Provide Visibility While Maintaining Privacy And Minimizing Noise. - Planning Relationships: A. Accessible To Staff Office - Lighting System: B. For General Illumination, Provide At Least 500 Lux. - Power System: C. Provide At Least Six (6) Units Of Outlet With Specifications Of 15a, 2p, 240v, Duplex, Grounding Type And Universal Slots. Also, Provide At Least One (1) Unit Of Outlet For Emergency Light With Specifications Of 15a, 2p, And 240v, Single. - Auxiliary System: D. Provide And Install The Following Auxiliary System: • Communication System  Telephone System – Provide At Least One (1) Unit Telephone Outlet.  Local Area Network System – Provide At Least One (1) Unit Data Outlet.  Public Address Paging System – Provide At Least One (1) Unit Paging System - Fire Alarm System: E. Provide At Least One (1) Unit Smoke Detector. - Air-conditioning System: F. Provide Air Conditioning System. • Administrative Records Room - This Room/area Is Where Hims Staff Stores/files Administrative Records For Easy Access And Retrieves Records On File. It Will Include An Operable Sliding Window At A Reachable Height, Allowing For Natural Ventilation And Lighting. - Planning Relationships: A. Accessible To Staff Office - Lighting System: B. For General Illumination, Provide At Least 150 Lux. - Power System: C. Provide At Least Six (6) Units Of Outlet With Specifications Of 15a, 2p, 240v, Duplex, Grounding Type And Universal Slots. Also, Provide At Least One (1) Unit Of Outlet For Emergency Light With Specifications Of 15a, 2p, And 240v, Single. - Auxiliary System: D. Provide And Install The Following Auxiliary System: • Communication System  Telephone System – Provide At Least One (1) Unit Telephone Outlet.  Local Area Network System – Provide At Least One (1) Unit Data Outlet.  Public Address Paging System – Provide At Least One (1) Unit Paging System - Fire Alarm System: E. Provide At Least One (1) Unit Smoke Detector. - Air-conditioning System: F. Provide Air Conditioning System - Security System: G. Provide At Least One (1) Closed – Circuit Television Cctv With At Least Two Views Or Angles. • File Storage Area - This Room/area Is Dedicated As Storage Of Inactive Files That Have Passed The Ten-to-thirty-year Filing Period, Of Files To Ensure Protection From Fire, Floor And Theft, For Periodic Evaluation Of Inactive Health Records/files, And To Keep Medical Records Accessible As Many Years As Possible. It Will Include An Operable Sliding Window At A Reachable Height, Allowing For Natural Ventilation And Lighting. - Planning Relationships: A. Adjacent To Hims Department - Lighting System: B. For General Illumination, Provide At Least 150 Lux. - Power System: C. Provide At Least Fourteen (14) Units Of Outlet With Specifications Of 15a, 2p, 240v, Duplex, Grounding Type And Universal Slots. Also, Provide At Least One (1) Unit Of Outlet For Emergency Light With Specifications Of 15a, 2p, And 240v, Single. - Auxiliary System: D. Provide And Install The Following Auxiliary System: • Communication System  Public Address Paging System – Provide At Least One (1) Unit Paging System - Fire Alarm System: E. Provide At Least Seven (7) Units Smoke Detector. - Air-conditioning System: F. Provide Air Conditioning System. - Security System: G. Provide At Least One (1) Closed – Circuit Television Cctv With At Least Two Views Or Angles. • Records Room - This Room/area Within The File Storage Area Is Where Hims Staff Stores/files Opd, Er, And Or/dr Records, Birth And Death Certificates For Easy Access, Retrieves Records On File For Request/follow-up Of Patients/relatives And Researchers/doctors And Refiles Them, And Records Individual Charts By Patient’s Data For Complete Inventory Control. - Planning Relationships: A. Adjacent To Hims Department - Lighting System: B. For General Illumination, Provide At Least 150 Lux. - Power System: C. Provide At Least Six (6) Units Of Outlet With Specifications Of 15a, 2p, 240v, Duplex, Grounding Type And Universal Slots. Also, Provide At Least One (1) Unit Of Outlet For Emergency Light With Specifications Of 15a, 2p, And 240v, Single. - Auxiliary System: D. Provide And Install The Following Auxiliary System: • Communication System  Public Address Paging System – Provide At Least One (1) Unit Paging System - Fire Alarm System: E. Provide At Least One (1) Unit Smoke Detector. - Air-conditioning System: F. Provide Air Conditioning System. - Security System: G. Provide At Least One (1) Closed – Circuit Television Cctv With At Least Two Views Or Angles. • Staff Pantry And Lockers - This Is The Lounging Area For Hims Staff And For Storing Of Their Personal Belongings. This Will Be Well-ventilated With Natural Lighting, Providing Ample Space For Pantry Furniture, A Refrigerator, A Stainless-steel Sink, And Steel Lockers Measuring 300 X 500 Mm. - Planning Relationships: A. Adjacent To Hims Department - Lighting System: B. For General Illumination, Provide At Least 500 Lux. - Power System: C. Provide At Least Four (4) Units Of Outlet With Specifications Of 15a, 2p, 240v, Duplex, Grounding Type And Universal Slots. Provide At Least One (1) Ground Fault Circuit Interrupter (gfci). Also, Provide At Least One (1) Unit Of Outlet For Emergency Light With Specifications Of 15a, 2p, And 240v, Single. - Auxiliary System: D. Provide And Install The Following Auxiliary System: • Communication System  Public Address Paging System – Provide At Least One (1) Unit Paging System - Fire Alarm System: E. Provide At Least Two (2) Units Smoke Detector. - Air-conditioning System: F. Provide Air Conditioning System. - Security System: G. Provide At Least One (1) Closed – Circuit Television Cctv With At Least Two Views Or Angles. • Staff Female And Male Toilet - Separate Staff Female And Male Toilets For Staff Use, Located Within The Staff Pantry And Lockers Area For Convenience And Accessibility. - Planning Relationships: A. Within Staff Pantry B. Adjacent To Hims Department - Lighting System: C. For General Illumination, Provide At Least 500 Lux. • All Gender/pwd Public Toilet - This Restroom Is Designed To Be Inclusive, Complying With The Updates To The Amended Irr Of Bp 344. It Ensures Accessibility For All Genders And Persons With Disabilities (pwd), Featuring Wide Doors, Support Bars, Urinal And Spacious Layout To Meet The Latest Standards For Accessibility And Comfort. - Planning Relationships: A. Directly Accessible To Public. B. Minimum Of One (1) Toilet On Each Floor Accessible To Disabled. - Lighting System: C. For General Illumination, Provide At Least 500 Lux. • Electrical/auxiliary Room - Located On The Ground Floor Near Staff Office Exit, It Is Strategically Placed Away From Direct Client/visitors Access To Maintain Separation And Safety While Ensuring Easy Access For Maintenance And Operation. - Lighting System: A. For General Illumination, Provide At Least 250 Lux. - Fire Alarm System: B. Provide At Least One (1) Unit Smoke Detector. - Lighting System: C. For General Illumination, Provide At Least 500 Lux. - Power System: D. Provide At Least One (1) Units Of Outlet With Specifications Of 15a, 2p, 240v, Duplex, Grounding Type And Universal Slots. Also, Provide At Least One (1) Unit Of Outlet For Emergency Light With Specifications Of 15a, 2p, And 240v, Single. • Access Ramp - Ramps Designed To Provide A Smooth, Accessible Pathway For Individuals With Mobility Challenges, Such As Wheelchair Users, To Enter Or Exit A Building. These Ramps Should Meet Accessibility Standards, Including Proper Slope (usually 1:12), Non-slip Surfaces, Handrails On Both Sides, And Clear Signage. They Are Essential For Ensuring Equal Access To All Areas Of A Building, In Compliance With Accessibility Laws Like The Amended Irr Of Bp 344. - Planning Relationships: A. A Ramp Shall Have A Minimum Clear Width Of 1.22 Meters (or 4 Feet) In One Direction (or 2.44 Meters Or 8 Feet In Two Opposite Directions). B. The Slope Of The Ramp Shall Not Be Steeper Than 1:12 Meters. - Lighting System: C. For General Illumination, Provide At Least 500 Lux. • Janitor’s Closet - This Room/space Is Designed To Keep Cleaning Materials With Mop Sink And As Storage For Janitor’s Cleaning Tools. This Will Be Strategically Located For Easy Access By Utility Workers, Ensuring They Can Reach It Without Needing To Pass Through The Staff Office. - Planning Relationships: A. Adjacent To Hims Department Office And Waiting Area - Lighting System: B. For General Illumination, Provide At Least 500 Lux. Upper Ground Floor – Multi-purpose Court • Covered Area For Proposed Multi-purpose Court - This Area Is Designed With A Covered Roof And Perimeter Walls At A Height Of 1.2 Meters For Safety, Providing Space For The Proposed Multi-purpose Court And Second-floor Offices, With Plans For Future Funding. - Planning Relationships: A. Accessible To Receiving/releasing Area - Lighting System: B. For General Illumination, Provide At Least 1000 Lux. C. Provide High Bay Led Lights - Power System: D. Provide At Least Six (6) Units Of Outlet With Specifications Of 15a, 2p, 240v, Duplex, Grounding Type And Universal Slots. Also, Provide At Least One (1) Unit Of Outlet For Emergency Light With Specifications Of 15a, 2p, And 240v, Single. - Security System: E. Provide At Least One (1) Closed – Circuit Television Cctv With At Least Two Views Or Angles. Xii. Structural Design And Analysis Specifications And Parameters A. Codes And Standards The Civil/structural Design Shall Be In Accordance With The Following Codes And Standards  Codes 1. National Structural Code Of The Philippines (nscp) 2010 2. National Building Code Of The Philippines And Its Revised Irr 3. Accessibility Law 4. Local Codes And Ordinances  Standards 1. Bureau Of Product Standards (bps) 2. Philippine National Standards (pns) 3. Dpwh Blue Book 4. American Concrete Institute (aci) 5. American Society For Testing Materials (astm) 6. American Welding Society (aws) B. Design Criteria Shall Be Submitted First To The Procuring Entity For Concurrence Of The Following Minimum Design Requirements: 1. Design Loads (dead Load, Live Load, Wind Load, Seismic Load And Analysis Procedure, Load Combinations) 2. Materials (concrete, Reinforcing Steel Bars, Structural Steels) 3. Foundation (allowable Foundation Pressure) 4. Design References C. Minimum Design Input File In Structural Software And Required Reports 1. Job Information 2. Joint Coordinates 3. Material Definition/specification 4. Member Property 5. Support Definition 6. Load Definition (seismic/dead/live/wind/load Combinations) 7. Analysis Procedure 8. Analysis Result 9. Load List 10. Support Reaction List 11. Design Results (footing/ Column/ Beam) 12. Load Diagrams 13. Structural Plans -end Of Structural Design And Analysis- Xiii. Design Parameters (architectural) A. Codes And Standards The Architectural Works Shall Be In Accordance With The Following Laws, Codes And Standards.  Laws And Codes: 1. National Building Code Of The Philippines And Its Latest And Amended Irr 2. Ra 9266 Or Architecture Law And Its Latest And Amended Irr 3. Ra 4226 Or Hospital Licensing Act And Its Latest And Amended Irr 4. Bp 344 Or Accessibility Law And Its Latest And Amended Irr 5. Ao 35, S. 1994 Or Ao Pertaining To The Control Of Radiation Hazards 6. Ra 9514 Fire Code Of The Philippines 7. Existing Local Codes And Ordinances. 8. And Other Laws That Applies To The Projects  Standards: 1. Bureau Of Product Standards (bps) 2 Underwriters Laboratory (ul) 2. Doh Technical Guidelines For Hospital & Health Facilities Planning And Design – Level 3 B. General Drawing Guidelines 1. General  All Drawings Shall Be Computer-drafted. Drawings Shall Be Submitted Both In Printed And Electronic Copies.  Keep The Same Orientation For All Plans. The North Orientation Shall Be Indicated In All Architectural Floor Plans. The Orientation Of The Architectural Plans Shall Be Consistent With All The Engineering Plans.  Existing Buildings And New Works Shall Be Clearly Indicated And Labeled In The Site Plans.  Detailed Plans Shall Have A Scale Not Smaller Than 1:50 Meters.  Spot Detailed Plans, Elevations, And Sections Shall Have A Scale Not Smaller Than 1:10 Meters.  Avoid Notes Such As ‘see Architectural Detail’ Or ‘see Structural’. Always Refer With A Callout To The Specific Detail Drawing And Sheet Number. 2. Site Plans  The Site Plans Shall Have A Scale Not Smaller Than 1:500 Meters. 3. Floor Plans  All Plans Shall Be 1:100 Meters. The Same Scale Shall Be Used For The Rest Of The Architectural, Structural, Sanitary, Plumbing, Electrical And Mechanical Plans, Except For Each Trade’s Site Plan, Detailed Plans And Spot Details.  Elevation Callouts Shall Be Indicated On The Floor Plans And Shall Be Consistent With The Elevation Drawing.  Section Line Callouts On The Floor Plans Shall Be Consistent With The Section Drawing.  Floor Plans Shall Be Indicated With Boxed Room Callout Numbers, Including The Callout For Floor Finishes And Wall Finishes.  Floor Elevations Shall Be Indicated In The Floor Plans. This Shall Be In Reference To The Natural Grade Line Or The Established Finished Floor Lines Of The Adjoining Existing Buildings.  The Location Of Mechanical Equipment, E.g. Air Conditioning Shall Be Indicated In The Floor Plans. This Shall Be Consistent With The Mechanical And Electrical Plans.  Door Callouts Shall Be Circles With The Proper Numbering, E.g. D-01.  Window Callouts Shall Be Hexagons With The Proper Numbering, E.g. W-01. 4. Elevations And Sections  Finish Floor Lines And Top Of Truss Lines Shall Be Consistent In All The Elevations, Sections And Structural Plans And Details. 5. Reflected Ceiling Plans  Reflected Ceiling Plans Shall Be Indicated With Boxed Room Callout Numbers, Including The Callout For Ceiling Finishes And Lighting Fixtures.  Ceiling Height Relative And In Reference To The Finish Floor Line Shall Be Indicated In The Reflected Ceiling Plans In Each Room With Boxed Dimensions. This Is To Ensure That The Ceiling Heights Of All Rooms Are Established Whether Or Not Reflected In The Sections.  The Description And Location Of The Fixtures, E.g. Lighting, Smoke Detectors, Air Condition Vents, Exhaust Fans, In The Reflected Ceiling Plans Shall Be Consistent With The Electrical And Mechanical Plans. 6. Roof Plans  Location Of All Downspouts Shall Be Indicated In The Roof Plans. 7. Doors And Windows  Door And Window Schedules Shall Indicate The Type Of Door Or Window, The Number Of Sets, The Location/s Of The Door Or Window, The Materials And Accessories Included And Other Special Specifications, E.g. Color Or Finish. All Windows Above Ground Floor Should Be Of Awning Window And All Awning Windows Should Be A 45-deg. Opening Angle. 8. Details  Provide A Minimum Of One (1) Bay Section Of A Scale Not Smaller Than 1:50 Meters For Each Major Building Preferably Cut Along The Area With Special Construction Design.  Provide Spot Detail Plans, Elevations And Sections Of A Scale Not Smaller Than 1:10 Meters For Special Designs With Aesthetic Treatment And Ornamentation.  Provide Detailed Plans Of A Scale Not Smaller Than 1:50 For All Areas Needing Tile Pattern, E.g. Lobby, Corridor, Entrance Walk, Showing The Position And Pattern Of Tiles.  Centerline Location Of Plumbing Fixtures Shall Be Indicated In Detailed Plans With Lines Of Reference And Its Corresponding Dimensions. This Is To Indicate The Exact Locations Of The Plumbing/sanitary Roughing-ins. C. Site Works 1. The Master Site Development Plan Of The Hospital Shall Include The Following:  Contour And Survey Of The Lot, Including Bearing And Distance Of The Property Line  Road Network And Curbs And Sidewalks  Parking Spaces  Reference Location Of Existing Trees  Reference Location And Footprint Of Existing Buildings, With The Corresponding Building Names And Dimensions, Including Distances Between Adjacent Buildings, And Distances Between Buildings And The Nearest Property Line  Reference Location Of Utilities, E.g. Water Reservoirs, Septic Tank, Wastewater Treatment Plant, Powerhouse, Transformers, Waste Storage Area, Security Outposts 2. The Layout Of The Buildings On The Site Shall Be Zoned According To The Service It Provides:  The Outer Zone Shall Include All Front-line Services, E.g. Emergency, Out-patient, X-ray, Laboratory And Other Ancillary Departments.  The Inner Zone Shall Include The Wards.  The Deep Zone Shall Include Services Like The Operating Room, Delivery Room, Nursery, Intensive Care Unit And Other Sensitive Hospital Services.  The Service Zone Shall Include Non-medical Services But Are Essential To Hospital Operations, E.g. Staff Lounge And Lockers.  There Shall Be A Separate Road Network And Entry/exit For The Public And The Service Vehicles, E.g. Ambulance, Waste Collection Vans, Delivery Trucks.  In Limited Lot Areas, Buildings Should At Least Be Spaced Four (4) Meters Apart To Allow Natural Light And Ventilation.  Covered Walkways Shall Be Provided For Access And Connection To All The Buildings.  Ramps Shall Be Provided In All Main Entrances Of The Buildings And Other Access Openings To Walkways Leading To Other Buildings. D. Building Architectural Works 1. Floor Plans  The Structural, Sanitary, Plumbing, Electrical And Mechanical Designs Are Required To Refer To The Architectural Plans And Specifications In Case Of Discrepancies. If An Engineering Design Will Have Any Possible Conflict Or Interference On The Architectural Design, The Latter May Be Adjusted Provided That The Aesthetic Value Will Not Be Compromised.  The Architectural And Engineering Plans Shall Be Consistent All Throughout In Terms Of Dimensions And Locations Of Columns, Beams, Walls, Roof Line, Conduits, Ducts, Pipes, And Fixtures, Among Others. Column And Beam Grid Lines Shall Also Be Consistent In All The Architectural And Engineering Plans.  Verify And Coordinate Floor Plans With The Mechanical, Electrical And Sanitary Design With Regard To The Requirements For Mechanical Rooms, Ahu Rooms, Electrical Rooms, Pipe Chase, And Other Engineering Requirements.  Public Toilets Shall Have Provisions And Fixtures For Persons With Disability As Required By Bp 344. If Enough Space Allows, Toilets Specially Made And Designated For Persons With Disability Is Preferable. 2. Walls  Exterior Walls Shall Be 200mm. Thick, While Interior Walls Shall Be 150mm. Thick. This Is Indicative Of The Finished Wall Thickness Including The Plastering And Tile Works.  Double Layer Of Drywall: Use Two Layers Of Drywall On Either Side Of A Metal Or Wood Stud Frame For Enhanced Soundproofing.  Acoustic Insulation: Use High-density Insulation Like Mineral Wool Or Acoustic Fiberglass In Wall Cavities To Absorb Sound.  Higher Mass: Increase The Wall's Mass With Materials Like Masonry Or High-density Concrete, Which Can Significantly Reduce Sound Transmission.  Toilet Wall Tiles Shall Be 300mm. X 300mm. For Areas Of Six (6) Square Meters Or Below. Toilet Wall Tiles Shall Be 300mm. X 600mm. For Areas Above Six (6) Square Meters.  Layout And Work On Wall And Floor Tiles Must Be Aligned, Plumb, Level, And Square.  All Edges, Corners And Intersections Of Toilet Tiles, Including The Top-most Tile Not Reaching The Ceiling Shall Be Provided With Polyvinyl Chloride Tile Trims.  Tile Color And Design Shall Be Approved First Before Installation. 3. Floors  If Floor Tiles In Two Adjacent Rooms With Different Material, Color Or Design Meet At The Door Opening, The Cut Shall Be Located Middle Of The Door Thickness When In A Closed Position. Provide Details In The Floor Pattern Design.  Floors At The Openings Of Toilets For Persons With Disability Shall Be Sloping. Indicate In The Plans And Sections.  The Size Of The Toilet Floor Tiles Shall Be 300mm. X 300mm. For Areas Of Six (6) Square Meters Or Below. Toilet Floor Tiles Shall Be 300mm. X 600mm. For Areas Above Six (6) Square Meters. Indicate The Tile Pattern.  The Size Of The Pantry/lounge Floor Tiles Shall Be 600mm. X 600mm. Indicate The Tile Pattern.  The Size Of The Floor Tiles Of The Offices And Wards Shall Be 600mm. X 600mm, Or Bigger Depending On The Proportion To The Size Of The Room. Indicate The Tile Pattern.  The Size Of The Floor Tiles Of The Lobby And Corridor Shall Not Be Less Than 400mm. X 400mm. The Tile Size Of 600mm. X 600mm. Is Recommended For Bigger Areas. Indicate The Tile Pattern.  Layout And Work On Wall And Floor Tiles Must Be Aligned, Plumb, Level, And Square.  All Edges, Corners And Intersections Of Toilet Tiles, Shall Be Provided With Polyvinyl Chloride Tile Trims.  Tile Color And Design Shall Be Approved First Before Installation. 4. Ceiling Works  Ceiling Height For Areas With Special Aesthetic Treatment, E.g. Lobby, Major Conference Room, Auditorium, Executive Office, Shall Be Proportional To The Area Or Room Or As Required By The Designer. However, This Shall Not Be Lower Than 2700mm. Provide Details.  If Acoustic Boards On Aluminum T-runners Would Be Used For The Ceiling, Layout Should Be On Center And Avoiding Cut Pieces. If The Remaining Perimeter Of The Ceiling Is Less Than 600mm. Wide, It Shall Be Designed Complimentary With Fiber Cement Boards On Light Gauge Metal Furring. Likewise With Acoustic Boards In Big Areas, E.g. Offices, And Wards, Shall Be Designed In A Way To Break The Redundancy. Provide Details.  Soffit Of Exterior Beams And Slabs Shall Have Drip Moulds To Prevent Damage Due To Water Sipping Into The Eaves Or Ceiling. Section Details Shall Be Required To Show The Drip-mould.  Acoustic Panels: Adding Absorptive Finishes, Such As Fabric-covered Acoustic Panels, Can Help To Dampen Internal Reflections And Improve Sound Quality Within Rooms, Although These Don’t Block Sound But Reduce Reverberation. 5. Doors And Windows  Major Rooms That Require Security Shall Have Sturdy Doors E.g. Wood Panel, And Metal.  Minor Rooms That Do Not Require Security Shall At Least Have Wood Flush Doors.  Toilets And Other Wet Areas Shall Have Steel Doors.  Heavy-use Doors, E.g. Operating Rooms, Delivery Rooms, Pwd Toilet Doors Should Be Provided With Stainless Steel Kick Or Push Plates And Door Closers.  Fire Escape Doors Should Be Provided With Panic Hardware And Door Closers, And Shall Conform With The Requirements Of The Fire Code Of The Philippines.  Aluminum Frames Of Glass Doors Shall Be Powder-coated.  Door Finish And Color Shall Be Approved First Before Application.  Window Sills Shall Be Slightly Sloped Outwards To Prevent Damage To Windows And Paint Due To Water Seepage. Section Details Shall Be Required To Show This Slope.  All Doors Of A High-occupancy Room Shall Swing Outwards And As Required By The Fire Code Of The Philippines.  Door Jambs With No Moulding/casing Installed On Concrete Walls Shall Have Construction Grooves All Around. Provide Details.  All Doors And Windows Shall Have Reinforced Concrete Lintel Beams. Provide Details.  Door Seals And Frames: For Soundproofed Rooms, Also Use Solid-core Doors With Perimeter Seals To Prevent Sound From Leaking Through Door Frames. 6. Stairs, Ramps And Corridors  Ramps For Persons With Disability Shall Have A Slope Not Higher Than 1:12. Handrails And Clearances Shall Conform With The Requirements Of Bp 344.  Regular Stairs Shall Have Risers At 150mm. High And Treads At 300mm. Wide. Fire Stairs Could Have A Maximum Riser At 200mm. And Tread At 250mm. Handrails Shall Be 1100mm. High. Clearances Shall Conform With The Requirements Of The Fire Code Of The Philippines.  Corridors Shall Have A Minimum Unobstructed Width Of 2450mm. This Shall Be Measured Clear From The Surface Of The Finished Wall And Not On-center Of The Rough Chb Wall.  Corridors Shall Not Be Areas For Temporary Or Permanent Storage Of Stretchers, Wheelchairs, Trolleys, Food Carts, Oxygen Tanks Or Other Movable Hospital Equipment. Storage Or Parking Spaces Shall Be Provided For These.  Corridors And Exit Doors Shall Conform With The Requirements Of The Fire Code Of The Philippines. 7. Fixtures And Accessories  Three-way Electrical Light Switches Shall Be Provided At The Foot And The Top Of The Stairs Per Floor. Likewise, At Both Ends Of A Long Corridor.  Electrical Light Switches Shall Be Located By The Knob Side Of The Door.  Electrical Switches And Outlets Shall Be Installed Plumb And Level.  Public Toilets Shall Always Be Provided With Heavy-duty Soap Dispensers And Electric Hand Dryers.  Public Toilets Shall Always Be Provided With Stainless Steel Handrails In Conformity To The Requirements Of Bp 344.  A Drainage Line Shall Be Provided For Window-type Air Conditioners. Likewise, Split-type Air Conditioners Located In The Interior Part Of The Building Shall Be Located Adjacent To Areas With Drainage Lines, E.g. Toilets, Downspouts, Balconies.  Seal Gaps And Openings: Ensure All Joints, Gaps, And Penetrations (e.g., Electrical Outlets, Ducts) Are Sealed With Acoustical Caulk Or Gaskets To Prevent Sound Leakage.  Sterile Area Lighting Type: Use Sealed, Recessed, Or Surface-mounted Led Fixtures That Are Flush With The Ceiling Surface To Prevent Dust Accumulation. 8. Roofing Works  The Section Of The Roof Gutters Shall Be Designed, In Case Of A Clogged Downspout, So That The Overflow Of Water Will Be Directed Outside Of The Building And Not Towards The Eaves Or Interior Ceiling To Prevent Any Damage. Provide Details.  Avoid Valley Or Inside Gutters In Roof Design. But In Cases Required In Aesthetic Design, Valley Or Inside Gutters Shall Be In Stainless Steel Or Concrete Gutters With Membrane-type Waterproofing, And The Section Shall Be Designed With A Capacity For Big Volume To Prevent Any Damage Due To Overflow. Provide Details.  Parapets, Designed As A Roof Protection From The Winds, Must Be Designed To Satisfy The Preceding Parameters. Provide Details.  The Slope Of The Roof Shall Not Be Less Than 30 Degrees. 9. Painting  Painted Ceiling Shall Be In Flat Latex Finish, While Cornices And Mouldings Shall Be In Gloss Enamel Finish.  Painted Interior Wall Shall Be At Least In Semi-gloss Latex Finish For Ordinary Rooms, E.g. Offices, Unless Specified To A Higher Type Of Paint.  Patient-related Rooms, E.g. Emergency Rooms, Out-patient Departments And Wards, Shall Be In Anti-bacterial And Odor-absorbent Paint Finish.  Special Rooms, E.g. Operating Rooms, Delivery Rooms, And Laboratories Shall Also Be In Anti-bacterial And Odor-absorbent Paint Finish.  Painted Exterior Wall Shall Be At Least In Moisture-resistant/water-repellent Solvent-based Paint Finish, Textured Or Smooth, Unless Otherwise Specified.  Paint Color And Shade Shall Be Approved First Before Application. D. Specific Requirements 1. Provide Spot Detail Plans And Sections Of The Following:  Gutter, Eaves, And Parapet  Ceiling - Covelight, Special Connections And Design, Mouldings, Valances  Stairs - Handrail, And Baluster Design  Ramps - Handrail Design And Floor Pattern  Doors, Windows And Gates - Grille Works,  Special Architectural Treatment And Design, E.g. Façade Design, Special Window And Door, Counter/transaction Window  Special Carpentry Works, E.g. Partitions, Cabinetry  Building And Room Signages And Wayfinding Systems  All Pwd Toilets Shall Be Labelled “all Gender / Pwd Toilet”  Other Details As May Be Required 2. Provide Room Data Sheets, Including Detail Floor Plan, Ceiling Plan And Sections Of The Following Rooms, In Coordination With The Requirements Of The Electrical, Sanitary And Mechanical Designs: A. Office, Including Furniture Arrangements And Outlets With Specific Dimensions Of The Location Of Fixtures And Accessories, And In Coordination With The Requirements Of The Electrical And Mechanical Engineering Design. B. Wellness Area C. Waiting Area D. E. (all Blanks Shall Be Filled As Required By Or Applicable To The Project.) E. Summary Of Materials  Materials To Be Used Shall Be Fire-resistant, Non-toxic, Moisture-resistant And Termite-resistant, E.g. Fiber Cement Board, Light-gauge Steel Frame, Polyvinyl Chloride Ceiling Panels.  Wet Areas, E.g. Toilets, And Pantry/lounge Shall Use Non-skid/non-slip Vitrified Ceramic Floor Tiles.  Heavy Traffic Areas, E.g. Lobby, And Corridor Shall Use Heavy-duty Seamless Granite Floor Tiles Or A Higher Type Of Floor Material.  Vinyl Floor Tiles For Sterile Areas Of Delivery & Nicu Suite Shall Be Homogenous And Not Less 3mm. Thick.  Ramps And Stairs Shall Use Non-skid/non-slip Floor Tiles, Materials As Specified.  Aluminum T-runners Shall Be Powder Coated.  Metal Rod Hangers With Adjustable Clips, And Not Galvanized Iron Wires, Shall Be Used To Support And Suspend The Aluminum T-runners And Light Gauge Metal Furrings.  Roofing Sheets Shall Be Ga.# 24 Aluminum-coated, Pre-painted, And Pre-formed. F. Drawing Requirements: See Attached Doh Checklist Of Drawings. -end Of Architectural Design Parameters- Xiv. Design Parameters (structural/civil Works) A. Codes And Standards The Civil/structural Design Shall Be In Accordance With The Following Codes And Standards  Codes 1. National Structural Code Of The Philippines (nscp) 2010 2. National Building Code Of The Philippines And Its Revised Irr 3. Accessibility Law 4. Local Codes And Ordinances  Standards 7. Bureau Of Product Standards (bps) 8. Philippine National Standards (pns) 9. Dpwh Blue Book 10. American Concrete Institute (aci) 11. American Society For Testing Materials (astm) 12. American Welding Society (aws) B. Site Works Based On The Master Site Development Plan Of The Hospital, Provide Where Applicable Complete Design And Details Of Hospital Road (concrete With Curb And Gutter, Including Drainage) Network, Walkways, Parking Areas And Fencing. 1. The Main Hospital Road Shall Be Capable Of Two-way Traffic (at Least 6mts. Width) With A Minimum Thickness Of 150mm (8 Inches). Concrete Strength Should Be At Least 3000psi. Interior Roads (leading To Support Facilities) Shall Be Designed To Accommodate Delivery Vehicles, And Fire Trucks In Case Of Emergency. 2. Walkway Should Be At Least 100mm Thk. With Concrete Strength Of 2500psi. Ramps Should Be Provided, Instead Of Steps, For Any Change In Elevations. 3. Parking Area Slabs Should Be At Least 150mm Thk. With Concrete Strength Of 3000psi. 4. Fences Should Be Seen Through In Front Of The Hospital While The Tree (3) Other Sides Should Be Concrete Hollow Blocks With Minimum Height Of 2 Meters And To Be Provided With Perimeter Lighting. See-through Fence Design Will Be Made Of 32mm Square Bars Spaced At 100mm On Center And Provided With Three (3) Concrete Hollow Blocks (45mm High) Zocalo Walls. C. Buildings 1. The Hospital Buildings Should Be Designed Using A Seismic Importance Factor Of 1.5 For The Immediate Occupancy Category. Buildings Should Be Designed In Accordance With Nscp Requirements Up To Magnitude 7 For Those Near Seismic Source Type A. Seismic Gaps Between Buildings (old And New) Should Be Properly Observed. 2. The Hospital Buildings Should Be Designed Also Using Wind Importance Factor Of 1.15 (especially For Design Of Trusses/roofing System). Concrete Gutters And Parapet Walls Should Be Provided As Additional Protection To The Roofing System During Strong Typhoons. Wind Velocity Of 300-350 Kph Shall Be Considered Upon The Recommendation Of Structural Engineer 3. The Structural Designer Should Verify With Philippine Volcanology And Seismology (phivolcs) The Distance Of The Proposed Hospital To Nearest Active Fault Lines And With The Denr For Geo-hazard Mapping. 4. Soil Investigation (at Least Three Boreholes) Should Be Conducted To Determine Soil Bearing Capacity And Recommended Foundation Design (applicable Even For One Storey Structure). 5. The Structural Designer Is Encouraged To Use Fire-resistive And Non-toxic Materials. D. Details – The Following Shall Be Provided: 1. Connection Details Of Beams And Columns Following The Requirements Of Nscp On Confined Areas. 2. Connection Of Trusses To Beams And Columns. 3. Splicing Details Of Reinforcing Bars On Columns And Beams And The Required Bar Cut-off Points. 4. Details For Connection Of New Construction & Old Construction Structural Members Such As Expansions Joints For Thermal Expansion/contraction. 5. Include Thermal Expansion/contraction Prevention Methodologies Specifically On Soft Joints Areas Between Structural And Architectural Members. E. Summary Of Materials 1. Concrete Shall Be Portland Cement And Conforming To Astm Specification C150, Type I To Type Ii 2. Coarse Aggregates Shall Consist Of Washed Gravel, Crushed Stone Or Rock Or A Combination Thereof Conforming To Astm C33 3. Concrete Hollow Blocks Shall Be A Standard Product Of Recognized Manufacturer Conforming To Pns 16 With At Least 350psi Strength. 4. Reinforcing Bars Shall Conform With Pns Grade 60 For 16mm Dia. And Above And Pns Grade 40 For 12mm Dia. And Below. 5. Structural Steel Shall Conform With Astm A36/a6m 6. Bolts And Studs Shall Conform With Astm A 325 7. Welding Electrodes Shall Be E60 Or E 70 And Conform With Aws F. Drawing Requirements: See Attached Checklist -end Of Structural/civil Works Design Parameters- Xv. Design Parameters (sanitary/plumbing Works) A. Codes And Standards The Sanitary/plumbing Design Shall Be In Accordance With The Following Codes And Standards.  Codes: 1. National Building Code Of The Philippines And Its New Irr 2. Fire Code Of The Philippines 3. National Plumbing Code Of The Philippines (npcp) 4. Sanitation Code Of The Philippines 5. Existing Local Codes And Ordinances.  Standards: 1. Bureau Of Product Standards (bps) 2. Philippine National Standards For Drinking-water 3. Underwriters Laboratory (ul) 4. Doh National \ Laboratory (nrl) 5. Doh Health Care Waste Management Manual 6. National Water Resources Board (nwrb) 7. National Plumbers Association Of The Philippines (nampap) 8. Philippine Society Of Sanitary Engineers, Inc. (psse) B. Site Works  Based On The Master Site Development Of The Hospital, The Site Works Shall Provide Complete Layout Of The Following: 1. Storm Drainage Network, Indicating Drainage Manholes And Pipe Culvert; 2. Sewerage Pipe Network, Indicating Sewage Manholes, Sewage Pipes And The Location Of The Proposed Sewage Treatment Plant; And 3. Water Supply Network, Indicating The Location Of Water Service Entrance, Cisterns, Elevated Water Tank And Proposed Pump House.  The Storm Drainage Network Shall Accommodate The Magnitude Of Peak Rates Of Surface Run-off Including Drainage Coming From The Buildings. The System Shall Be Capable Of Handling The Design Flows Routing To The Designated Outfall; For Rainfall Calculation And Sizing Of Drainage Pipes, Refer To Table-d2, Appendix-d, National Plumbing Code Of The Philippines And Current Rainfall Record From Pagasa.  The Sewerage Pipe Network Design Shall Accommodate All Sewage Coming From All The Facilities, Conveyed By Gravitational Flow Leading To The Sewage Treatment Plant; Per Capita Wastewater Demand: 100-130 Gal/capita/day Per Bed C. Building Facilities Sanitary/plumbing System 1. Sewer Line And Vent System  Provide Complete Sewer Line And Vent System From All (domestic) Plumbing Fixtures And Floor Drains, Laid By Gravity Flow Leading To The Sewage Treatment Plant (stp);  For Demand Weight Of Fixtures In Fixture Units; Refer To Appendix A, Table A-2, Npcp 2. Wastewater Line And Vent System  For All Wash Areas Dealing And Generating With Oil/grease, Provide Separate Waste Line And Vent System And Solely Tap To The Proposed Grease Trap And Then Connect Its Effluent To The Sewage Treatment Plant.  For Estimated Demand Weight Of Fixtures In Fixture Units; Refer To Appendix A, Table A-2, Npcp Waterline System  Provide Complete Cold Water Supply Pipes To All Plumbing Fixtures. From The Main Water Source, The Water Shall Be Pumped To The Elevated Water Tank (ewt) And Conveyed To The Fixtures By Gravity System And Or Distributed To Fixtures By Transfer Pumped With Constant Pressure Through A Pneumatic Storage Tank, Whichever Is Feasible. 4. Storm Drainage System  Complete Storm Drainage System Shall Be Provided For All Roofs, Canopies, Concrete Ledges And Balconies Including Condensate Drains Laid For Gravity Flow Connected To A Leader/pipe Line Leading To The Natural Ground Level Storm Drainage Network. D. Summary Of Materials  Sewer And Vent Pipes; Unplasticized Polyvinyl Chloride (upvc) Extra Series 1000 (conforming To Iso 3633 Astm D2729 Including Trims And Fittings)  Storm Drainage Pipes; Downspouts, Unplasticized Polyvinyl Chloride (upvc) Extra Series 1000 (conforming To Iso 3633 Astm D2729 Including Trims And Fittings, Bps Certified)  Drainage Pipes; 250mm Dia. And Below, Non-reinforced Concrete Pipe (nrcdp)  300mm Dia. And Above, Reinforced Concrete Pipe (rcdp)  Drainage Manholes; Street Inlet, Curb Inlet, Traffic Type Reinforced Concrete Area Drain/catch Basin, Reinforced Load Bearing Chb  Sewage Manholes; Traffic Type Reinforced Concrete With Standard Steel Brass Cover  Wastewater Pipeline; Extra Heavy (xh) Single Hub, Hub Less Cast Iron Pipes And Fittings (cip) Conforming To Astm Standard 888  Cleanouts; Cast Iron Brass With Countersunk Plug (bps Certified)  Floor Drains/deck Drains; Cast Iron Brass (bps Certified)  Gutter Drains; Cast Iron Dome Type Brass (bps Certified)  Cold Waterline Pipes; For Buildings, Polypropylene Pn10 Fusion Weld Pipes Including Trims And Fittings (bps Certified)  Hot Waterline System; For Buildings, Polypropylene Pn20 Fusion Weld Pipes Including Trims And Fittings (bps Certified)  Trench Grating; Galvanized/stainless Steel Iron Grates  Plumbing Fixtures Including Trims, Fittings And Accessories; (bps Certified)  Water Closet-tank Type Push Button Flush  Lavatory - (pedestal/counter Type) With C-spout Spray Faucet  Kitchen Sink-ga#16 Stainless Steel Seamless Bowl With Gooseneck Faucet  Urinal-wall Hung Flush Valve Type E. Drawing Requirements: See Attached Doh Checklist Standards Based On Revised Irr Of The National Building Code Of The Philippines (pd 1096) -end Of Sanitary/plumbing Works Design Parameters- Xvi. Design Parameters (mechanical Works) A. Codes And Standards The Mechanical Design Shall Be In Accordance With The Following Codes And Standards.  Codes: 1. National Building Code Of The Philippines And Its New Irr 2. Fire Code Of The Philippines 3. Mechanical Engineering Code Of The Philippines (me Code) 4. Existing Local Government Codes And Ordinances.  Standards: 1. Bureau Of Product Standards (bps) 2. Philippine National Standards (pns) 3. Underwriters Laboratory (ul) And Factory Mutual (fm) 4. International Electrotechnical Commission (iec) 1988 5. National Fire Protection Association (nfpa) 6. National Fire Protection Association (nfpa) 99 Standard For Health Care Facilities. 7. American Society Of Heating, Refrigeration And Air Conditioning Engineers (ashrae). 8. Center For Disease Control And Prevention (cdc) Manual. B. Automatic Fire Sprinkler System  The Automatic Fire Sprinkler System Shall Be Composed Of Complete Plans And Drawings Of The Following: 1. Site Development Plan And Vicinity Map, Indicating The Location Of The Buildings, Firewater Reserve Tank, Firewater Line, Yard Loop And Private Fire Hydrant. 2. General Notes, Legends And Symbols Including Schematic Diagram Of The Fire Sprinkler System And Schematic Diagram Of Alarm Monitoring System. 3. Floor Layout And Isometric Layout Of The Automatic Fire Sprinkler System Indicating Pipe Sizes And The Location Of The Pipes, Valves, Sprinkler Heads, Riser Nipples, Fire Hose Cabinets, Sprinkler Main Riser, Drain Pipes, Cross Mains, Branch Lines, Inspector’s Test Connections, Hangers And Sway Braces. 4. Equipment Schedule, Detail Drawings, Fire Pump And Jockey Pump Layout. 5. Architectural, Structural, Electrical And Plumbing Drawings Of The Firewater Tank And Pumphouse.  An Automatic Fire Sprinkler Shall Be Provided In All Hospital Building Except For Those Fire Resistive One-storey Hospital Building.  Hazard Classification Shall Be Light Hazard Occupancy.  Area Of Coverage Shall Be 146 Square Meters And Water Density Shall Be 4.07 Lps/sq. M.  Protection Area Per Sprinkler Head Shall Be 20 Square Meters At 2.2 Meters Minimum Distance Between Sprinklers And 4.2 Meters Maximum Spacing.  All Floor Control Valves Shall Be Equipped With Supervisory Switch, Water Flow Detector And Drain System.  Water Supply Shall Be Horizontal Split Case Centrifugal Fire Pump With Diesel Engine Or Ac Motor And A Vertical In-line Jockey Pump With Controller.  Firewater Reserve Tank Shall Be Ground Level Monolithic Concrete Tank Sized For A Minimum Of 30 Minutes.  Hydraulic Calculations Report Shall Be Based On Npfa-13 Format. C. Ventilation And Air Conditioning System  The Ventilation And Air Conditioning System Shall Be Composed Of Complete Plans And Drawings Of The Following: 1. General Notes, Legends And Symbols Including Schematic Diagram Of The Ventilation And Air Conditioning System. 2. Floor Layout Of The Ventilation And Air Conditioning System Indicating The Capacity And Location Of The Air Conditioners And Fans. 3. Duct Layout Indicating Duct Sizes, Route And Location Of The Dampers, Diffusers, Return Air Register, Hangers And Sway Braces. 4. Refrigerant Piping Layout Indicating Pipe Sizes, Location Of Valves, Hangers And Sway Braces. 5. Equipment Schedule And Details Drawings Of Air Conditioners And Ventilating System.  Air Conditioning System Shall Be Provided In All Patient’s Private Rooms, Operating Rooms, Delivery Rooms, Offices And Other Areas Where Conditioned Air Is Necessary.  Cooling Load Calculations Report Shall Be Manual Or Computer Generated, Hourly Analysis Program Which Includes Heat Transmission Coefficients, Solar Heat Gain Factors And Corrected Cooling Load Temperature Difference Calculations.  Split Type Air Conditioners Will Be Used At Areas With Larger Capacities.  Window Type Air Conditioners Shall Be Used In Areas With Exterior Wall Exposure.  Centralized Air Conditioning Will Be Used As Indicated On Space Requirements (e.g. Sterile Hallways).  Maintain An Air Change Rate Greater Than Or Equal To 12 Air Changes Per Hour Or 145 Liters Per Second Per Patient.  Ceiling Cassette Type Exhaust Fans With Integral Air Diffuser Shall Be Provided In All Toilets.  Ceiling Fans, Orbit Type With 360° Oscillation Shall Be Provided In All Non-air-conditioned Rooms, As Mentioned On Space Requirements. D. Summary Of Materials 1. Automatic Fire Sprinkler System A. The Fire Pump Shall Be Ul Listed/fm Approved, Diesel Engine Or Electric Motor Driven, Designed Specifically Intended For An Automatic Water Sprinkler Protection System. B. The Jockey Pump Shall Be Ul Listed/fm Approved, Electric Motor Driven, 220v, 3-phase, 60 Hertz, And Electric Power Connection. C. Sprinkler Head Shall Be Ul Listed/fm Approved, Pendant, Upright Or Sidewall Unit, 83 Lpm Flow Capacity Per Head And Temperature Fusing At 57.5° C To 74°c. D. The Alarm Assembly Shall Be Ul Listed/fm Approved, Constructed And Installed That Any Flow Of Water From The Sprinkler System Equal To Or Greater Than That From The Single Automatic Head Shall Result In An Audible And Visual Sign In The Vicinity Of The Building. E. Alarm And Supervision System Of The Automatic Water Sprinkler Shall Include The Monitoring Water Flow Switch At Each Floor Of The Building, Fire Pump And Jockey Pump Running Condition And Power Supplies, Level Of Water In The Reservoir And Control Valves. F. Pipes Shall Be B.i. Schedule 40. Screw Fittings Shall Be Used For Inside Piping. 2. Air Conditioning And Refrigeration System A. Refrigerant Pipes Shall Be Copper Tubing, Type L Or K Black Steel Pipe, Schedule 40 For Size Of 100mm Diameter And Smaller. Pipe Over 100mm Shall Be Black Steel Pipe Schedule 40. B. Black Steel Pipes Shall Be Standard Seamless, Lap-welded, Or Electric Resistant Welded For Size Of 50mm Diameter And Larger, Screw Type For Size 38mm Diameter And Smaller, Fittings For Copper Tubing Shall Be Cast Bronze Fitting Designed Expressly For Brazing. C. Pipe Insulation Shall Be Performed Fiberglass Or Its Equivalent. The Insulating Materials Shall Be Covered With 100mm X. 13mm Thick Polyethelene Film, Which Shall Be Overlapped Not Less Than 50mm. D. Ducts Shall Be Galvanized Sheet Steel Of Standard Gauges. E. Ductwork Insulation Materials Shall Be Rigid Board Made Of Styropor Or Equivalent 25mm Thick For Ground And Top Floor, 13mm Thick For Intermediate Floor. -end Of Mechanical Works Design Parameters- Xvii. Design Parameters (electrical/auxiliary Works) A. Codes And Standards The Electrical System Design Parameters Shall Be In Accordance With The Following Codes And Standards.  Codes: 1. Philippine Electrical Code 2. National Electrical Code 3. Fire Code Of The Philippines 4. National Building Code Of The Philippines And Its New Irr 5. Existing Local Codes And Ordinances  Standards: 1. Bureau Of Product Standards (bps) 2. Underwriters Laboratory (ul) 3. National Fire Protection Association 4. International Electrotechnical Commission (iec) 5. Illumination Engineering Society (ies) 6. National Electrical Manufacturer’s Association (nema) 7. Doh Manual On Technical Guidelines For Hospital And Health Facilities Planning And Design B. Building Facilities Electrical System 1. Lighting System  Provide And Install Adequate Normal Branch Circuits For Lighting System To All Areas Using The Standard Lighting Design Analysis. Utilize The Standard Illumination Requirements Per Area Of Concern Using The Preferred Particular Type Of Luminaires. 2. Power System  Provide And Install Adequate Normal Branch Circuits For The Power System. 3. Standby/emergency System  Provide And Install Adequate Life Safety And Critical Emergency Branch Circuits For Lighting Or Utilization Equipment Connected To The Alternate Power Source. 4. Auxiliary System Provide And Install The Following Auxiliary System:  Communication System A. Telephone System B. Local Area Network System C. Public Address Paging System D. Private Branch Exchange (pabx) E. Master Or Cable Antenna Television  Fire Alarm System  Security System 5. Lightning Protection System  The Building Lightning Protection System Shall Include Roof-mounted Air Terminals Grounding Conductors, Ground Rods, Conduits, Clamps, And Auxiliary Equipment As Required For A Complete And Operational Lightning Protection System. 6. Provide Details Of The Following:  Lighting Fixtures/luminaires  Panelboard And Circuit Breakers  Switchgear And Other Metering Devices  Electrical And Hospital Equipment  Installation And Termination Of Auxiliary And Other Special Devices And Equipment  Power And Telephone Handholes (as May Be Required)  Pedestal And Service Entrance To Bldg.  Grounding System Layout  Substation/power House And Electrical Room  Transformer And Generator Mounting  Others As May Be Required. C. Summary Of Materials  General Lighting Luminaries: Fixtures Type Shall Be As Indicated On The Lighting Layout Plan. 1. Fluorescent Lamp Shall Be Linear, Circular Or Self-ballasted Compact Fluorescent Lamps. 2. Fluorescent Lamps Shall Be Cool Or Warm White And 3. Lamp Holders Shall Be Made Of Thermosetting Plastic. 4. Fluorescent Ballast: Magnetic Or Electronic Type With High Power Factor Or High Frequency Energy Saving Type. 5. Fluorescent Fixture Housing Shall Be Steel Sheet With High Reflectance Powder Coat Paint Finish. 6. Downlights And Pin Lights Shall Be Of Heavy Gauge Spun Aluminum Equipped With Lamp As Indicated On The Drawings. 7. Other Special Lighting Requirements Shall Be As Approved By The Implementing Agency.  Wiring Devices: Wiring Devices Shall Be Non-automatic Control Devices, The Contact Is Guaranteed By The Pressure Of The Special Spiral Springs. 1. Switches Shall Be Of 15a, 250v Or 300v Except As Otherwise Noted And Approved. Terminals Shall Be Screw-type Or Quick-connected Type. 2. General Use Receptacle Shall Be 15a, 240v Grounding Type Unless Otherwise Indicated On The Drawings. 3. Special Purpose Receptacles Shall Be As Called For On The Drawings. 4. Matching Plugs Shall Be Supplied.  Panelboards And Circuit Breakers: The Panelboard And Circuit Breakers Shall Be Equipped With Molded-case Circuit Breakers And Shall Be The Type As Indicated In The Panelboard Schedule And Details. 1. Provide Molded-case Circuit Breakers Of Frame, Trip Rating And Interrupting Capacity As Shown On The Drawings. The Circuit Breakers Shall Be Quick-make, Quick Break, Thermal-magnetic, Trip-indicating And Shall Have Common Trip On All Multiple Breakers With Internal Trip Mechanism. 2. All Current-carrying Parts Of The Panelboards Shall Be Plated. Provide Solid Neutral (s/n) Assembly When Required. The Assembly Shall Be Isolated From The Enclosure.  Electrical Conduits, Boxes And Fittings: All Conduits, Boxes And Fittings Shall Be Standard Rigid Steel, Zinc Coated Or Galvanized. 1. Rigid Steel Conduits (rsc) 2. Rigid Metal Conduits (rmc) 3. Intermediate Metal Conduits (imc) 4. Electrical Metallic Tubing (emt) 5. Unplasticized Polyvinyl Chloride (upvc) If Required Shall Be Schedule 40.  Conductors: Wires And Cables Shall Be Of The Approved Type And Unless Specified Or Indicated Otherwise, All Power And Lighting Conductors Shall Be Insulated For 600 Volts. 1. The Conductors Used In The Wiring System Shall Be Of Soft-annealed Copper Having A Conductivity Of Not Less Than 98% Of That Of Pure Copper And Insulated For 60° C Temperatures. 2. All Conduits Of Convenience Outlets And Wire-ways For Lighting Branch Circuit Home-runs Shall Be Wired With A Minimum Of 3.5 Mm Square In Size.  Master Antenna Television (matv) And Cable Television (catv) System: 1. Two Sources Of Tv Signals Shall Be Provided To The Building. One (1) Shall Be From A Master Antenna Installed At The Roof Or Within A Suitable Area Of The Building And The Other Will Be From A Commercial Cable Television Service. 2. The Master Antenna System Shall Consist Of Fm, Vhf And Uhf Antennas, Combiner, Distribution Amplifier, Coaxial Cables, Splitters, Tap-offs And Tv Outlets. 3. There Shall Be Individual Trunking For Master Antenna And Cable Television Rising In The Building.  Structured Cabling & Telephone System: 1. A Minimum Provision For Estimated 500 Mixed Pabx Extension And Direct Telephone Lines Shall Be Required For Tertiary Hospitals. 2. Final Details Of The System Shall Follow Specific Requirements, Quantity And Type Of Service.  Fire Detection And Alarm System: 1. The Fire Detection And Alarm System Shall Be Of Multiplex, Microprocessor- Controlled Addressable Or Zonal Conventional Fire Detection, Alarm And Communication System. 2. The System Shall Consist Of Full Integration Automatic Fire Detection, Voice Alarm Communication And Fire Fighters Telephone System. 3. The System Shall Consist Of Control Station, Mimic Panel Initiating And Indicating Devices, Control Modules And System Of Wirings. 4. Actuation Of The Protective Signaling System Shall Occur By Manual Pull Station, Automatic Smoke Or Heat Detector, Sprinkler Flow Switch And Tamper Switch. 5. The System Shall Be Able To Monitors The Status Of Flow Switches And Supervisory Switches Installed At The Sprinkler System Risers. These Monitoring Points Are Also Addressable Or The Conventional Zonal In The Same Way As The Detectors Are Making Them Easily Recognizable At The Control Panel. 6. Occupant Notification Shall Be Accomplished Automatically. Notification Will Be General, Audible Alarm Type Complying With Appropriate Section Of Nfpa. 7. The System Shall Be Installed With Provisions For Future Connection To The Nearest Fire Services Station In The Locality.  Security System: 1. The Security System Shall Include Intrusion Detection And Alarm, Cctv, Access Control Or As Maybe Required.  Ventilation And Air Conditioning System The Ventilation And Air Conditioning System Shall Be Composed Of Complete Plans And Drawings Of The Following: 1. General Notes, Legends And Symbols Including Schematic Diagram Of The Ventilation And Air Conditioning System. 2. Floor Layout Of The Ventilation And Air Conditioning System Indicating The Capacity And Location Of The Air Conditioners And Fans. 3. Duct Layout Indicating Duct Sizes, Route And Location Of The Dampers, Diffusers, Return Air Register, Hangers And Sway Braces. 4. Refrigerant Piping Layout Indicating Pipe Sizes, Location Of Valves, Hangers And Sway Braces. 5. Equipment Schedule And Details Drawings Of Air Conditioners And Ventilating System. A) Air Conditioning System Shall Be Provided In All Patient’s Private Rooms, Radiologic And Imaging Area, Operating Rooms, Delivery Rooms, Laboratories, Critical Care Areas, Offices And Other Areas Where Conditioned Air Is Necessary. B) Cooling Load Calculations Report Shall Be Manual Or Computer Generated, Hourly Analysis Program Which Includes Heat Transmission Coefficients, Solar Heat Gain Factors And Corrected Cooling Load Temperature Difference Calculations. C) Split Type Air Conditioners Will Be Used At Areas With Larger Capacities. D) Window Type Air Conditioners Shall Be Used In Areas With Exterior Wall Exposure. E) Centralized Air Conditioning Will Be Used Only If Feasible. F) Design Of All Critical Areas Shall Be Laminar Or Positive Pressure, Wherein The Supply Air Is 10% More Than Exhaust Air. G) All Infectious Isolation Rooms, Such As Tb And Sars, Shall Be Negative Pressure, Wherein The Exhaust Air Is More Than 10% Of The Supply Air. H) Maintain An Air Change Rate Greater Than Or Equal To 12 Air Changes Per Hour Or 145 Liters Per Second Per Patient. I) Ceiling Cassette Type Exhaust Fans With Integral Air Diffuser Shall Be Provided In All Toilets. J) Ceiling Fans, Orbit Type With 360° Oscillation Shall Be Provided In All Non-air-conditioned Rooms, Such As Waiting Area.  Air Conditioning And Refrigeration System 1. Refrigerant Pipes Shall Be Copper Tubing, Type L Or K Black Steel Pipe, Schedule 40 For Size Of 100mm Diameter And Smaller. Pipe Over 100mm Shall Be Black Steel Pipe Schedule 40. 2. Black Steel Pipes Shall Be Standard Seamless, Lap-welded, Or Electric Resistant Welded For Size Of 50mm Diameter And Larger, Screw Type For Size 38mm Diameter And Smaller, Fittings For Copper Tubing Shall Be Cast Bronze Fitting Designed Expressly For Brazing. 3. Pipe Insulation Shall Be Performed Fiberglass Or Its Equivalent. The Insulating Materials Shall Be Covered With 100mm X. 13mm Thick Polyethylene Film, Which Shall Be Overlapped Not Less Than 50mm. 4. Ducts Shall Be Galvanized Sheet Steel Of Standard Gauges. 5. Ductwork Insulation Materials Shall Be Rigid Board Made Of Styropor Or Equivalent 25mm Thick For Ground And Top Floor, 13mm Thick For Intermediate Floor. -end Of Electrical Works Design Parameters- Xviii. Design Parameters (green And Safe Health Facilities)  Codes And Standards Green And Safe Health Facilities Shall Be In Accordance With The Following Laws, Codes And Standards.  Global Initiatives & Developments: 1. World Health Assembly Resolution On Universal Health Care (2019) 2. World Health Resolution On Climate Change And Health (2008) 3. Un Resolution On Sustainable Development Goals (2015) 4. Global Action On Patients’ Safety  Laws And Codes: 1. Sanitation Code Of The Philippines Irr Of Chapter Xvii 2. The Local Government Code Of 1991 3. Clean Water Act Of 2004 4. National Building Code Of The Philippines (pd 1096) 5. General Appropriation Act Fiscal Year 2021 (ra 11518) 6. Occupational Safety And Health (ra 11058) 7. Safe Hospital Initiative (2011) 8. Universal Health Care Act (ra 11285) 9. Implementing Rules And Regulations Of Accessibility Law (ra 344) 10. Ecological Solid Waste Management Act Of 2000 (ra 9003) 11. Climate Change Act Of 2009 (ra 9729) 12. Other Related Standards A. Guidelines The Green And Safe Hf Initiative Represents A Climate Smart Paradigm Shift, Away From Traditional Disaster Response To One That Proactively Seeks To Minimize The Health Impact Of Disasters And Emergencies Through Climate Adaptation And Mitigation Measures (including Climate-proofing And Reduction Of The Environmental Footprint), And Preparedness. Consequently, It Is Essential That This Green Manual Is Incorporated Into The Hospital And Hf Development Agenda That Are Backed With Earmarked Resources In The National Budget, And That Has Governance And Support From The Highest Levels Of Government.  The Department Of Health Shall, As Much As Possible, Promote The Greening Of Hospitals And Health Facilities, Including The Improvement Of Energy And Water Efficiency And Conservation, Sustainable Cooling Systems, And Sustainable Healthcare Waste Management In Hospitals.  In Line With Its Continuing Efforts In Green And Safe Hfs, The Doh Shall Encourage National And Local Government Hospitals And Other Hfs To Seek Green Certifications From Green Building Rating System/s For Their New Construction Or Expansion, Repair And Renovation Projects. B. Criteria And Compliance System For Outstanding Green And Safe (climate Smart) Health Facilities.  Criterion Compliance 1. Governance – Leadership And Management, Trainings, Proper Implementation, Commitment 2. Energy Efficiency – Reduction Of Energy Consumption, Use Of Renewable And Clean Energies 3. Water Efficiency, Sanitation And Hygiene – Adequate Water, Water Reuse/recycling, Water Conservation, Rainwater Harvesting. Safe Drinking Water, Proper Use And Maintenance Of Sanitary Toilet Facilities 4. Health Care Waste Management Waste – Segregation, Collection, Storage, Transport, Treatment, Proper Waste Disposal, Recycling 5. Environmentally Resilient Health Facility – Structural Member, Non-structural Member, Emergency And Disaster Preparedness Plan 6. Site Sustainability – Healing Gardens Within, Fresh Air, Herbal Plants, Accessibility, Existence Of Alternative Routes 7. Material Sustainability – Use Of Sustainable Materials, Procurement Of Sustainable And Recyclable Products, Less Use Of Hazardous And Toxic Substances 8. Indoor Environmental Quality – Lighting, Ventilation, Interior Design, Air Quality Management C. Energy Efficiency  Orientate Building & Façade Design To Mitigate Heat Gain. The East And West Facades Receive The Greatest Solar Radiation, And Should Be Designed To Avoid Direct Sun.  Use Of Glass/glazing With A Lower U-value And Shading Coefficient Reduce Solar Heat Gain.  Allow Provision For Easy Access For Maintenance And Cleaning Especially For Curtain Wall System.  Consider Lifespan, Durability And Life Cycle-costing When Selecting Façade Materials.  Install And Use Energy-efficient Lighting Fixtures I.e. Led, Cfl, Slim Type Fluorescent, Etc.  Skylights (if Applicable) And Windows To Maximize Natural Lighting And Ventilation On Selected Areas. Utilizing Daylight As Possible.  Use Of Appliance With Inverter Technology With Variable Frequency Drive Technology.  Window And Door Assemblies Shall Have Complete Gaskets, Weather Stripping, Door Bottom Sweeps And Seals.  All Operable Windows Shall Be Provided With Safety Features For Protection Against Strong Winds, Water Penetration And Protection For Building Occupants Including Child Safety And Security.  Specific Air Exchange Rates Are Usually Attained Through Artificial Ventilation. Adequate Ventilation Throughout The Facility Contributes To Maintaining A Hygienic Environment. Presence Of Functional Windows And Doors, That Allow At Least 6-8 Air Changes Per Hour For Natural Ventilation. For Airborne Infection Isolation Room/s And Er/triage Areas, Greater Or More Than 12 Air Changes Per Hour Is Recommended, While Up To 15 Air Changes Per Hour May Be Recommended For Operating Procedure, Or Delivery Rooms.  Light-colored Building Envelopes Is Also Recommended To Reduce Heat Transfer From The Outside To Inside Of The Building By Having Surfaces With High Solar Reflectance Index (sri). D. Water Efficiency, Sanitation And Hygiene  Optimize Water Conservation Through Installation Of Rainwater Harvesting Cistern Tank  Use Of Waterless Urinals And Dual Flush Water Closets.  Use Of Low-flow & Water Efficient Faucet And Hand-held Bidets.  Use Of Water-saving Shower Heads  For Hospitals, There Must Be At Least One Water Closet For Every Eight Patients In Compliance With Ra 4226 – Hospital Licensure Act.  A Separate Toilet For Male And Female Is Preferred, And Shall Be Pwd Accessible. And, A Separate Toilet For The Staff, With A Provision Of One Toilet For Every Fifteen Personnel Shall Be Applied.  Waterless Urinals Must Be Provided For Male Toilets.  There Should Be Sufficient And Functional Hand-washing Facilities. E. Environmentally Resilient Health Facility  Ground Floor Must Be Above Ground Line And Anticipated Flood Level. F. Material Sustainability  Building Materials, If Applicable, Must Be Locally Sourced To Minimize Carbon Footprint.  Rapidly Renewable And Sustainable Materials Are Also Recommended. Refer To Sec. 16.3.4 Of Doh Green And Safe Health Facilities Manual For List Of Sustainable Construction Materials That Can Be Used.  Use Of Materials (specifically Wet-applied Materials) That Are Low In Vocs (volatile Organic Compounds) G. Site Sustainability  Adopt The Development Controls Indicated In The National Building Code Of The Philippines To Establish The Extent Of The Health Facility Site Can Develop.  Biophilic Design Is Recommended To Help Reduce Stress, Improve Cognitive Function And Creativity, Improve Patients’ Well-being And Expedite Healing.  Porous Pavement Is Recommended At The Site Development To Alleviate Flooding. Landscape Swales Is Also One Solution. H. Indoor Environmental Quality  Harvest Natural Daylight If Applicable.  Acoustic Quality, Especially In Areas/rooms That Needs To Be Soundproofed, Shall Be Maintained.  Use Of Acoustic Privacy Partitions Is Required.  Separate Entrances For Ambulances And Walk-in Patients.  In Procedure Rooms With Windowless Areas, Backlit Photomurals Or Artificially Illuminated Glass Artwork Can Alleviate Feeling Of Claustrophobia.  In Wards And Recovery Rooms, Provide Windows And Natural Illumination As Much As Possible.  Provide Acoustic Privacy In Patient Rooms, Offices, And Examination Rooms With Partitions Of Sound Transmission Class (stc) Of 45.  Noise Level In The Operational Rooms Must Follow The Minimum Noise Standards In Accordance To The Doh Manual Of The Technical Guidelines For Hospital Planning And Design (level 3) Drawing Requirements: See Doh Standard Checklist Based On Revised Irr Of The National Building Code Of The Philippines (pd 1096). Checklist Of Drawing Requirements In The Preparation/evaluation/approval Of Detailed Architectural And Engineering Plans And Other Documents For Infrastructure Project Implementation. -end Of Green And Safe Health Facilities Design Parameters- Xix. Build Aspect Furnish Labour, Materials, Equipment, Paint, Tools And Other Facilities To Complete The Entire Building Including Architectural, Structural/ Civil, Electrical, Mechanical, Sanitary, Communication, Fire Protection, And Other Related Works To Complete The Scope As Specified And/or As Shown On Drawings And Plans 1. General Requirement  Contractor’s Temporary Facility And Lay Down Yard.  Communication And Transmittal, Reproduction, Tarpaulin/billboard And Photos  Material Testing (rsb, Chb, Concrete, Steel)  Safety Requirements (warning Signs, Hardhat, Etc.)  As Built Plan  Demolition, Clearing Work, Permits And Licenses 2. Other Items Of Work  Demolition Of Existing Structures In Affected Areas Or Where The Proposed Project Shall Be Situated, Clearing And Disposal Of All Debris Generated During Construction.  All Serviceable Materials Shall Be Turn Over To Doh-dedvmh Through Its Representative  Soil Excavation And Soil Treatment  Restoration Of Any Damaged Properties During The Construction  Permit Fees, And Other Necessary Documents For The Project Shall Be Shouldered By The Contractor  Temporary Facilities Shall Be Provided During The Construction Period, To Be Constructed Within The Hospital Compound, Which Shall Serve As The Field Office, Storage Of Materials And Bunkhouse For The Workers.  No Implementation Of The Project Without An Approved Plan And Other Related Documents.  Strict Implementation Of (dole Guidelines And Other Standards Applicable) Health And Safety Rules.  Shall Abide By The Medical Center Hospital House Rules  Conduct Weekly Progress And Coordinative Report To The Agency Or Its Representative  Other Items Of Work Not Mentioned Herewith But It Is Very Necessary For Execution And Completion Or Works Shall Be Included And Charge To The Contractor 3. Pre-installation Requirements  All Tests To Be Conducted Shall Be Witnessed By The Hospital Representatives.  Soil Investigation  Concrete Strength Testing  Reinforcing Bar Strength Testing  Concrete Masonry Unit (cmu) Testing  All Plumbing And Sanitary System  Automatic Fire Sprinkler System  Ventilation And Air Conditioning System  All Electrical System  And Other Tests That Necessary To Perform To Ensure The Quality Of The Project  All Certifications And Reports Under Post-installation Requirement Shall Be Submitted To The Hospital Representatives.  The Contractor Shall Submit A Sample Of Materials For Approval Of The Medical Center Chief Prior To Installation.  No Implementation Or Execution Of Work In Any Discipline Without The Approval Of Medical Center Chief Or Through Its Representative  Any Request For Inspection, Approval, Concrete Pouring, Testing And Commissioning Must Be Address To Medical Center Chief Or Must Adhere To The Reporting Protocol As Mentioned Above. -end Of Build Aspect- Checklist Of Drawing Requirements In The Preparation/evaluation/approval Of Detailed Architectural And Engineering Plans And Other Documents For Infrastructure Project Implementation Reference: Revised Implementing Rules And Regulations Of The National Building Code Of The Philippines (pd 1096) Project : Location : Sheet Number Sheet Contents Remarks* Architectural Drawings (as Applicable) A – 1 (a…n) Perspective, Site Development Plan, Vicinity Map/location Plan (2.00 Kms. Radius) Table Of Contents A – 2 (a…n) Floor Plans (scale 1:100m Minimum) Including Furniture Layout When Necessary A – 3 (a…n) Four (4) Elevations (scale 1:100m Minimum) A – 4 (a…n) Two (2) Sections (scale 1:100m Minimum) Including Spot Details When Necessary A – 5 (a…n) Roof Plan/s Showing Downspouts (scale 1:100m Minimum), Including Detail Of Gutter, Downspout, Etc. A – 6 (a…n) Reflected Ceiling Plan/s (scale 1:100m Minimum), Including Details A – 7 (a…n) Details Of Stairs, Fire Escapes/exits, Accessible Ramps, Etc. (scale 1:50m), Including Details Of Railings, Treads, Risers, Etc., In The Form Of Plans, Elevation/section A – 8 (a…n) Details Of Toilets (1:50 M) Including Accessible Toilets In The Form Of Plans, Elevation/section A – 9 (a…n) Details Of Specialized Design Features (scale 1:50 M) Such As Partitions, Cabinets, Etc. And Accessible Design Features A – 10 (a…n) Detail Of Typical Bay Section From Ground To Roof (scale 1:50 M) A – 11 (a…n) Details Of Special Elevations/section Rooms (1:50m) In Form Of Plans, A – 12 (a…n) Schedule Of Doors, Gates, Emergency Exits, Etc. (scale 1:50 M), Including Specifications For Materials And Hardware A – 13 (a…n) Schedule Of Windows (scale 1:50 M), Including Specifications For Materials And Hardware A – 14 (a…n) Schedule Of Finishes For Interior And Exterior Floors, Walls, Ceilings Architectural Technical Specifications Architectural Scope Of Works Architectural Bill Of Quantities * To Be Marked As Either Complying Or Non-complying/complete Or Incomplete By The Evaluator Or To Be Filled With Supporting Comments (use Additional Sheets If Necessary) Evaluated By: ____________________________________________________________ Page 1 Of 6 Checklist Of Drawing Requirements In The Preparation/evaluation/approval Of Detailed Architectural And Engineering Plans And Other Documents For Infrastructure Project Implementation Reference: Revised Implementing Rules And Regulations Of The National Building Code Of The Philippines (pd 1096) Project : Location : Sheet Number Sheet Contents Remarks* Architectural Interior Design Drawings (as Applicable) Aid – 1 (a…n) Floor Plans Showing Layout Of Floor Finishes (scale 1:100m Minimum) Aid – 2 (a…n) Floor Plans Showing Layout Of Furniture/finishing Partitions, Cabinets, Etc. (scale 1:100m Minimum) Aid – 3 (a…n) Interior Elevations And Sections Showing Wall Patterns, Ceiling Sections, Etc. (scale 1:100m Minimum) Aid – 4 (a…n) Details Of Partitions, Cabinets, Furniture, Ceiling And Other Interior Design Features (scale 1:100m Minimum) Aid – 5 (a…n) Architectural Interior Perspective/s Architectural Interior Design Technical Specifications Architectural Interior Design Scope Of Works Architectural Interior Design Bill Of Quantities * To Be Marked As Either Complying Or Non-complying/complete Or Incomplete By The Evaluator Or To Be Filled With Supporting Comments (use Additional Sheets If Necessary) Evaluated By: ____________________________________________________________ Page 2 Of 6 Checklist Of Drawing Requirements In The Preparation/evaluation/approval Of Detailed Architectural And Engineering Plans And Other Documents For Infrastructure Project Implementation Reference: Revised Implementing Rules And Regulations Of The National Building Code Of The Philippines (pd 1096) Project : Location : Sheet Number Sheet Contents Remarks* Structural Drawings (as Applicable) S – 1 (a…n) General Notes And Construction Standards S – 2 (a…n) Site Development Plan S – 3 (a…n) Foundation Plan/s (scale 1:100m Minimum) S – 4 (a…n) Floor Framing Plan/s (scale 1:100m Minimum) S – 5 (a…n) Roof Framing Plan (scale 1:100m Minimum) S – 6 (a…n) Schedule And Detail Of Footings And Columns S – 7 (a…n) Schedule And Detail Of Beams And Floor Slabs S – 8 (a…n) Detail Of Trusses S – 9 (a…n) Details Of Stairs, Ramps, Fire Exits S – 10 (a…n) Other Spot Details Structural Analysis And Design (for 2 Storey Building And Higher) Boring And Land Test Results (for 3 Storey Building And Higher) Seismic Analysis Structural Technical Specifications Structural Scope Of Works Structural Bill Of Quantities * To Be Marked As Either Complying Or Non-complying/complete Or Incomplete By The Evaluator Or To Be Filled With Supporting Comments (use Additional Sheets If Necessary) Evaluated By: ____________________________________________________________ Page 3 Of 6 Checklist Of Drawing Requirements In The Preparation/evaluation/approval Of Detailed Architectural And Engineering Plans And Other Documents For Infrastructure Project Implementation Reference: Revised Implementing Rules And Regulations Of The National Building Code Of The Philippines (pd 1096) Project : Location : Sheet Number Sheet Contents Remarks* Electrical Drawings (as Applicable) E – 1 (a…n) General Notes And Legends E – 2 (a…n) Location And Site Plan E – 3 (a…n) Lighting Layout (scale 1:100m Minimum) Including Details E – 4 (a…n) Power Layout (scale 1:100m Minimum) Including Details E – 5 (a…n) Auxiliary System Layout (scale 1:100m Minimum) Including E – 6 (a…n) Schedule And Detail Of Loads E – 7 (a…n) Riser Diagram E – 8 (a…n) Other Detail Electrical Computation Design Analysis Electrical Technical Specifications Electrical Scope Of Works Electrical Bill Of Quantities * To Be Marked As Either Complying Or Non-complying/complete Or Incomplete By The Evaluator Or To Be Filled With Supporting Comments (use Additional Sheets If Necessary) Evaluated By: ____________________________________________________________ Page 4 Of 6 Electronics/auxiliary System Ready For Integrated Communications 1. Telephone System 2. Paging System 3. Lan System 4. Fire Alarm System 5. Security System Cctv 6. Integrated Communications And Systems Checklist Of Drawing Requirements In The Preparation/evaluation/approval Of Detailed Architectural And Engineering Plans And Other Documents For Infrastructure Project Implementation Reference: Revised Implementing Rules And Regulations Of The National Building Code Of The Philippines (pd 1096) Project : Location : Sheet Number Sheet Contents Remarks* Plumbing/sanitary Drawings (as Applicable) P – 1 (a…n) General Notes And Legends P – 2 (a…n) Location And Site Plan P – 3 (a…n) Storm Drainage Layout (scale 1:100m Minimum) Including Actual Length Of Tapping Line To Main Drainage Line P – 4 (a…n) Waterline Layout (scale 1:100m Minimum) Including Actual Length Of Tapping Line From Main Water Source When Applicable P – 5 (a…n) Sewerline Layout (scale 1:100m Minimum) Including Actual Length Of Tapping Line To Septic Tank Or Existing Sewerline P – 6 (a…n) Isometric Layout, Showing Waterline, Sewerline And Drainage Line P – 7 (a…n) Detail Of Connections, Catch Basins, Downspouts, Etc. P – 8 (a…n) Detail Of Septic Tank/sewer Treatment Plant Design Analysis Sanitary Technical Specifications Sanitary Scope Of Works Sanitary Bill Of Quantities * To Be Marked As Either Complying Or Non-complying/complete Or Incomplete By The Evaluator Or To Be Filled With Supporting Comments (use Additional Sheets If Necessary) Evaluated By: ____________________________________________________________ Page 5 Of 6 Checklist Of Drawing Requirements In The Preparation/evaluation/approval Of Detailed Architectural And Engineering Plans And Other Documents For Infrastructure Project Implementation Reference: Revised Implementing Rules And Regulations Of The National Building Code Of The Philippines (pd 1096) Project : Location : Sheet Number Sheet Contents Remarks* Mechanical Drawings (as Applicable) M – 1 (a…n) General Notes And Legends, Site Development Plan, Location Plans M – 2 (a…n) Floor Plans/isometric Drawings (scale 1:100m Minimum) Showing Ventilation And Air Conditioning Systems And Other Installations M – 3 (a…n) Floor Plans/isometric Drawings (scale 1:100m Minimum) Of Gas Pipeline System And Details M – 4 (a…n) Floor Plans/isometric Drawings (scale 1:100m Minimum) Of Air-conditioning Systems And Details M – 5 (a…n) Floor Plans/isometric Drawings (scale 1:100m Minimum) Of Fire Suppression Systems, Fire Sprinkler System, Wet Stand Pipe, Dry Standpipe And Other Installation M – 6 (a…n) Details Water Tank, Flow Diagram (scale 1:50m) M – 7 (a…n) Details Of Firewater Supply Sytem (scale 1:50m) M – 8 (a…n) Detail Of Elevators, Escalators, Dumbwaiters, Etc. (scale 1:50m) M – 9 (a…n) Detail Of Other Machinery/equipment (scale 1:50) M – 10 (a…n) Longitudinal And Transverse Section Of Building (scale 1:100m) Showing Manner Of Support Of Machines/equipment Mechanical Technical Specifications Mechanical Scope Of Works Mechanical Bill Of Quantities * To Be Marked As Either Complying Or Non-complying/complete Or Incomplete By The Evaluator Or To Be Filled With Supporting Comments (use Additional Sheets If Necessary) Evaluated By: ____________________________________________________________ Page 6 Of 6 General Guidelines • All Construction Works Shall Be Undertaken By Contractor In Accordance With Existing Laws And All Other Applicable Rules And Regulations. • The Contractor Shall Be Responsible In Setting Out Reference Lines, Elevations (lines And Grades) Prior And During The Execution Of The Works. All References Shall Be Maintained And Protected By The Contractor At His Own Expense. Disturbed References Shall Be Restored To Its Original Position Without Extra Cost To Devmh. • The Contractor Shall Carry Out The Works Properly And In Accordance With This Contract. The Contractor Shall Provide All Supervision, Labor, Materials, Plant And Equipment, Which May Be Required. • The Contractor Shall Commence Execution Of The Works On The Start Date And Shall Carry Out The Works In Accordance With The Approved Pert/cpm Network Diagram Submitted By The Contractor, As Updated With The Approval Of The Procuring Entity’s Representative, And Shall Complete The Works By The Intended Completion Date. • The Contractor Shall Be Responsible For The Safety Of All Activities On The Site. • During On-going Construction And Before The Turn-over Of The Project, Engineering & Facilities Management Staff, End-users, Twg And Bac Shall Inspect The Works Undertaken By Contractor. Hospital Engineers And End-users Discover Any Deviations By Contractor From The Approved Construction Plans, Contractor Shall Be Required To Rectify All Such Deviations, Within Such Period Required By Client. • Contractor Shall Have Full Responsibility For Any And All Damages To Existing Hospital Facilities, Utilities, And/or Any Portion Of The Hospital’s Common Area, Due To The Works Undertaken By Contractor, Whether Accidental Or Intentional. • No Variation Order Shall Be Undertaken Unless Verified By Hospital Engineer And Approved By Executive Committee. • Contractor Shall Not Cover Or Block Stub-outs (cleanouts, Water Source, Exhaust, Sewer, Drainage, Etc.) When Not Utilized. Said Stub-outs Shall At All Times Be Free Of Obstructions And Easily Accessible. • Contractor Shall Secure A Utility Tapping Permit Prior To Tapping From Utility Provision. • Electricity And Water Consumed During Construction Shall Be Charged To Contractor. • End-users Reserves The Right To Inspect The Works At Any Time. • Contractor Shall Insure And Hold Client, Its Affiliates, Officers, Directors, Stockholders, Employees, Agents, And/or Representatives, Free And Harmless From And Against Any Injury, Losses, Claims, Damages, Liabilities, Expenses, And/or Costs Of Litigation, Resulting From Or Arising Out Of The Works Undertaken By Contractor. • In Event Of Force Majeure, The Contractor Shall Rectify, Replace Or Build The Unfinished Projects When It Is Not Yet Completed And Accepted W/o Additional Cost For The Procuring Entity. • Contractor Shall Comply With The Construction House Rules Of This Hospital.
Closing Date16 Dec 2024
Tender AmountPHP 30 Million (USD 507.9 K)

Stadt Brandenburg An Der Havel, Der Oberb rgermeister, Tiefbauamt, SG 66 1 Stra en Und Br cken Tender

Civil And Construction...+1Road Construction
Germany
Details: Road construction and electrical work: 830 m² asphalt milling; 830 m² concrete pavement breaking up; 630 m² concrete base layer C 25/30, 20 cm thick; 200 m² paving from concrete paving; 100 Ifm curbs laid from concrete; 240 Ifm retaining wall made from concrete; 50 Ifm galvanized railings made; 630 m² asphalt base layer made from Ac 32 Ts; 630 m² asphalt binder course made from Ac 16 Bs Sg; 8 pieces of street lighting including cable laying; 50 m drainage pipe laid.
Closing Date10 Dec 2024
Tender AmountRefer Documents 

Batangas State University Tender

Philippines
Details: Description Republic Of The Philippines Batangas State University Batangas City Request For Quotation "procurement Of Semi-expandable Ict Equipment For Various Offices " 1. The Batangas State University (batstate U) Through The Bids And Awards Committee Invites Interested Firms/supplier To Submit Quotation For The Project "procurement Of Semi-expandable Ict Equipment For Various Offices " With An Approved Budget For The Contract (abc) Four Hundred Fifty-eight Thousand Five Hundred Pesos Only (php 458,500.00). Quotation Received In Excess Of The Abc Shall Be Automatically Rejected At The Opening. Item No. Qty Description Total 1 4 Unit All In One Printer Functions : Print, Scan, Copy Memory: 128mb Display: 1 Line Lcd Interface: Hi-speed Usb 2.0 Wired/wireless Network: Wireless Lan Print Speed (laser Comparable): Up To 17ipm (mono) And 16.5ipm (colour) Print Speed (fast Mode): Up To 30ppm (mono) And 26ppm (colour) Print Resolution: Up To 1200 X 6000 Dpi 2-sided Print: Automatic (up To A4/ltr) Direct Wireless Connection: Wi-fi Direct Maximum Copy Size: A4 Copy Speed (laser Comparable): Up To 13ipm (mono) And 10.5ipm (colour) Copy Speed (fcot): Up To 10.5 Sec (mono) And 21 Sec (colour) Copy Resolution (colour): Print Max. 1200 X 2400 Dpi; Scan Max. 1200 X 600 Dpi Maximum Scan Size: Up To A4 Scan Resolution: Optical: Up To 1200 X 2400 Dpi; Adf: Up To 1200 X 600 Dpi) Scan Speed: From 3.35 Sec/4.38 Sec (a4 Size, 100 X 100 Dpi) Paper Input (standard Type): Up To 150 Sheets (80g/m2) Paper Output: Up To 50 Sheets (up To A4) Paper Handling Sizes: A4, Ltr, Exe, A5, A6, Photo 4" X 6", Indexcard 5" X 8", C5 Envelope, Com-10, Dl Envelope, Monarch 57,600.00 2 1 Unit All-in-one Color Ink Tank Printer Function: Multi-function (print, Scan & Copy) Output Color: Color Print Technology: Inkjet Print Speed: Black - 8.8ppm; Color - 5ppm Number Of Nozzles: Total 1,472 Nozzles Resolution: 4800 X 1200dpi (max.) Paper Size: A4, A5, B5, Letter, Legal, 4 X 6 Inch, 5 X 7 Inch, 8x 10 Inch, Envelopes (dl, Com10), Square (5 X 5 Inch), Business Card. Custom: (width 55 – 215.9mm, Length 89 – 676mm) Paper Type: Plain Paper, High Resolution Paper, Photo Paper Plus Glossy Ii, Photo Paper Plus Semigloss, Matte Photo Paper, Envelope, Glossy Photo Paper, Photo Sticker Paper Weight: Plain Paper: 64 – 105g/m2, Canon Specialty Paper 275g/m2; Photo Paper Plus Glossy Ii (pp-201). Input Capacity: 100 Sheets Input Tray Output Capacity: 50 Sheets Output Tray Duplex Printing: Manual (driver Support Provided) Scanner Type: Flatbed Scanning Speed: 19s Scan Resolution: 600 X 1 200dpi Scan Paper Size: A4, Letter 10,700.00 Multiple Copy: 1 – 20 Pages Copy Speed: 3.5ppm Connectivity: 1 Hi-speed Usb 2.0, Wi-fi Display: 1.2 Inch Segment Lcd Display Wireless: Yes, Ieee 802.11n / Ieee 802.11g / Ieee 802.11b Ink Tank: Yes Power: Input Voltage: Ac 100 – 240v; 50 / 60hz; Power Consumption: 11w (1.2w Standby) Ink Bottle: Gi-790 Black (6,000) Pages, Gi-790 Cyan, Magenta, Yellow (7,000) Pages 3 3 Unit All-in-one Ink Tank Printer Printer Type: Print, Scan, Copy Print Method: On-demand Inkjet (piezoelectric) Printer Language: Esc/p-r, Esc/p Raster Nozzle Configuration: 180 X 1 Nozzles Black, 59 X 1 Nozzles Per Colour (cyan, Magenta, Yellow) Maximum Resolution: 5760 X 1440 Dpi Automatic 2-sided Printing: No Print Speed: Photo Default - 10 X 15 Cm / 4 X 6 " *1: Approx. 69 Sec Per Photo (border) / 90 Sec Per Photo (borderless)*2 Draft, A4 (black / Colour): Up To 33.0 Ppm / 15.0 Ppm*2 Iso 24734, A4 Simplex (black / Colour): Up To 10.0 Ipm / 5.0 Ipm*2 First Page Out Time From Ready Mode (black / Colour): Approx. 10 Sec / 16 Sec*2 Maximum Copies From Standalone: 20 Copies Maximum Copy Resolution: 600 X 600 Dpi Maximum Copy Size: A4, Letter Iso 29183, A4 Simplex (black / Colour): Up To 7.0 Ipm / 1.7 Ipm Scanner Type: Flatbed Colour Image Scanner Sensor Type: Cis Optical Resolution: 600 X 1200 Dpi Maximum Scan Area: 216 X 297 Mm Scanner Bit Depth (colour): 48-bit Input, 24-bit Output Scanner Bit Depth (grayscale): 16-bit Input, 8-bit Output Scanner Bit Depth (black & White): 16-bit Input, 1-bit Output Flatbed (black / Colour): 200dpi: Up To 11 Sec / Up To 32 Sec Number Of Paper Trays: 1 Standard Paper Input Capacity: Up To 100 Sheets Of Plain Paper (80 G/m2); Up To 20 Sheets Of Premium Glossy Photo Paper Output Capacity: Up To 30 Sheets Of Plain Paper (80 G/m2); Up To 20 Sheets Of Premium Glossy Photo Paper Maximum Paper Size: 215.9 X 1200 Mm Paper Sizes: Legal (8.5 X 14"), Indian-legal (215 X 345 Mm), 8.5 X 13", Letter, A4, 16k (195 X 270 Mm), B5, A5, B6, A6, Hagaki (100 X 148 Mm), 5 X 7", 5 X 8", 4 X 6", Envelopes: #10, Dl, C6 Print Margin: 0 Mm Top, Left, Right, Bottom Via Custom Settings In Printer Driver*3 Operating System Compatibility: Windows Xp / Xp Professional / Vista / 7 / 8 / 8.1 / 10 Windows Server 2003 / 2008 / 2012 / 2016 / 2019 Mac Os X 10.6.8 Or Later Usb: Usb 2.0 Printer Software: Epson Scansmart 28,800.00 4 5 Unit Color Document Scanner Specifications Scanner: 249,500.00 Scanner Type: Sheet-fed, 1-pass, Duplex Color Scanner Optical Resolution:600 Dpi Maximum Resolution:1200 Dpi Interpolated Monochrome Bit Depth:1-bitoutput Resolution:50 To 1200 Dpi Effective Pixels:5100 X 9300 Light Source:3-color Rgb Led Scanning Speed:letter Size: 45 Ppm/70 Ipm: 300 Dpi Black-and-white, Color, Gray Automatic Document Feeder: Capacity:100 Sheets Document Sizes: Paper Size Minimum: 2" X 2" Paper Size Maximum: 8.5" X 240" At 200 Dpi, 8.5" X 215" At 300 Dpi Daily Duty Cycle: 5,000 Sheets Paper Weight: 27 –413 G/m2 Consumables: Roller Assembly Kit: 200,000 Pages General: Operating Systems: Windows® 10 Windows 8/8.1 Windows 7 Mac Os X® 10.9.8 – Macos® 10.12.x Software Requires Internet Connection For Download And Installation. Temperature: Operating: 41 ° To 95 °f (5 ° To 35 °c) Storage: -13 ° To 140 °f (-25 ° To 60 °c) Humidity: Operating: 10 – 80% (no Condensation) Dimensions: Product Only: 11.7" X 7.7" X 12.5" Product In Package: 14.5" X 9.9" X 11.5" Weight: Product Only: 8.1 Lb. Product In Package: 10.6 Lb. 5 4 Unit Computer Speaker Dimensions Height: 110 Mm Width: 90 Mm Depth: 88 Mm Weight: .25 Kg Technical Specifications Total Watt (rms): 1.2w 3.5 Mm Input: 1 Usb Cable For Power: 1 Controls Power And Volume Controls On Right Speaker 3,000.00 6 3 Unit Computer Web Camera Resolution: Full Hd 1080p, 1920*1080 Pixels Lens Type: Full Hd Glass Lens Viewing Angle: 70 Degrees Focus Type: Fixed Focus Focus Range: 60cm And Beyond Built-in Mic.: Digital Hd Mic. Output Format: Mjpeg Frame Rate: 30fps Usb: Usb 2.0 System Requirements Compatible With: Windows 7 /8 / 8.1 / 10 Or Later Works In Usb Video Device Class (uvc) Mode: Mac Os 10.10 Or Later 3,900.00 Linux Os 2.6 Or Later Chrome Os 6.0 Or Later Android V6.0 Or Later Compatible With Social And Video Calling Software Of The Above System 7 1 Unit Dot Matrix Printer Print Method: Impact Dot Matrix Print Direction: Bi-direction With Logic Seeking Number Of Pins In Head: 9 Pins Print Speed: High Speed Draft: (10 / 12 / 15 Cpi): 347 / 357 / 390 Cps (condensed, 17 / 20 Cpi): 383 / 298 Cps Draft: (10 / 12 / 15 Cpi): 260 / 312 / 223 Cps (condensed, 17 / 20 Cpi): 222 / 260 Cps (emphasized, 10 Cpi): 130 Cps Nlq: (10 / 12 / 15 / 17 / 20 Cpi): 65 / 78 / 55 / 47 / 56 Cps Reliability: Printhead Life: Approx. 400 Million Strokes/wire Mean Print Volume Between Failure (mvbf): Approx. 20 Million Lines (except Print Head) Mean Time Between Failure (mtbf): Approx. 10,000 Poh (25% Duty) Print Characteristics: Character Sets: Italic Table, Pc437 (us Standard Europe), Pc850 (multilingual), Pc860 (portugese), Pc861 (icelandic), Pc863 (canadian French), Pc865 (nordic), Abicomp, Brascii, Roman 8, Iso Latin 1, Pc 858, Iso 8859-15 Paper Path: Manual Insertion: Rear In, Top Out Push Tractor: Rear In, Top Out Paper Media: Cut Sheet (single Sheet): Length: 100 ~ 364mm (3.9 ~ 14.3") Width: 100 ~ 257mm (3.9 ~ 10.1") Thickness: 0.065 ~ 0.14mm (0.0025 ~ 0.0055") Cut Sheet (multi-part Forms): Length: 100 ~ 364mm (3.9 ~ 14.3") Width: 100 ~ 257mm (3.9 ~ 10.1") Thickness: 0.12 ~ 0.39mm (0.0047 ~ 0.015") (total) Continuous Paper (single Sheet / Multi-part): Length: 101.6 ~ 558.8mm (4.0 ~ 22.0") Width: 101.6 ~ 254.0mm 4.0 ~ 10.0") Thickness: 0.065 ~ 0.39mm (0.0025 ~ 0.015") (total) Envelope (no.6): 14,000.00 Page 4 Of 5 Item No. Qty Description Total Length: 92mm (3.6") Width: 165mm (6.5") Thickness: 0.16 ~ 0.52mm (0.0063 ~ 0,0205") (total) Envelope (no.10): Length: 105mm (4.1") Width: 241mm (9.5") Thickness: 0.16 ~ 0.52mm (0.0063 ~ 0.0205") (total) Roll Paper: Width: 216mm (8.5") Thickness: 0.07 ~ 0.09mm (0.0028 ~ 0.0035") Supported Os And Applications: Supported Os: Microsoft® Windows® 2000 / Xp / Vista / 7 / 8 / 8.1 / 10 8 6 Piece External Hard Drive Connection Interface: Usb 3.0 Capacity: 1tb Storage Media: 2.5" Hdd 19,200.00 9 1 Unit Monitor 34 Inches” Wqhd (3440x1440) High Resolution 21:9 Ultra Wide Display 121% Srgb 144hz High Refresh Rate Immersive 1500r Curvature 144hz Curved Monitor 20,000.00 10 14 Piece Ssd Form Factor 2.5? Capacity 1 Tb Interface Sata Iii Dimensions (l X W X H) 0.28? X 3.96? X 2.75? Sequential Read Performance 535mb/s Sequential Write Performance 450mb/s" 51,800.00 Note: Kindly Indicate The Brand On Your Quotation. 2. Philgeps Registration Certificate And Other Business Permits Shall Be Attached Upon Submission Of The Quotation. 3. The Quotation Must Be Submitted (can Also Be Send Thru Fax And Email At The Contact Details Listed Below) Or To The Rizal Avenue Extension, Batangas City And Shall Be Received By The Committee On Or Before 5:00 Pm Of December 04, 2024. E-mail : Procurement.central.external@g.batstate-u.edu.ph 4. The Bsu Reserves The Right To Reject Any Or All Quotations And/or Proposals And Waive Any Formalities/informalities Therein And To Accept Such Bids It May Consider As Most Advantageous To The Agency And To The Government. Batstate U Neither Assumes Any Obligation For Whatsoever Losses That May Be Incurred In The Preparation Of Bids, Nor Does It Guarantee That An Award Will Be Made. Mr. Jonas Erik L Ebora Assistant Director, Procurement Rizal Avenue Extension, Batangas City 980-0385 Loc. 1230
Closing Soon4 Dec 2024
Tender AmountPHP 458.5 K (USD 7.7 K)

Department Of Agriculture Tender

Electronics Equipment...+1Electrical and Electronics
Philippines
Details: Description Invitation To Bid Supply And Delivery Of Various Ict Equipment For Use Of Rsbsa For 2025 Project 1. The Department Of Agriculture Regional Field Office No. 5 (da Rfo 5), Through The National Expenditure Program (nep) For Fy 2025-rsbsa Program Intends To Apply The Sum Of Three Million Five Hundred Eleven Thousand Pesos (php3,511,000.00) Being The Total Abc To Payments Under The Contract For Itb No. 09-goods-rsbsa- 2025 , As Follows: Description Abc (php) (inclusive Of Vat) Funding Source Supply And Delivery Of Various Ict Equipment Nep Rsbsa2025 A3 Dtf Printer Bundle For Epson L1800 Directly Transfer Film Dtf Printer With Oven Dryer A3 Dtf Machine For T-shirt All Fabric 110,502.00 A1 Printer (594 X 841 Mm) Inkjet, Refillable Tank 98,000.00 75" Smart Screen Information Monitor W/ Video Wall Controller, Cables, Ups And Portable Steel Stand 259,000.00 Validators Aio Desktop Set 280,000.00 Digital Receiver Wireless Gooseneck Conference Microphone System 128,100.00 Interactive Georeferencing Control Panel 132,000.00 Geospatial Processing Mobile Pc 190,000.00 Georeferencing Laptop 320,000.00 Encoding Laptop Set 280,000.00 Plotter Printer With Cartridge Ink 190,000.00 Interactive Dashboard 75" Touch Screen Display 412,000.00 Kobo Collection Equipment 550,000.00 Lower Earth Orbit Internet Device With Subscription 106,600.00 Rapid Aerial Monitoring And Assessment Mini Uav 75,000.00 Georeferencing Rendering Equipment 130,000.00 Portable Intelligent Energy Transformation Equipment 249,798.00 Total ₱3,511,000.00 Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. Partial Bid Is Not Allowed. 2. The Department Of Agriculture Regional Field Office No. 5 Now Invites Bids For The Following. Description Location Of Project Qty Specifications Unit Price Delivery Of The Goods Supply And Delivery Of Various Ict Equipment Da Rfo 5 San Agustin, Pili, Cam. Sur 1 Set A3 Dtf Printer Bundle For Epson L1800 Directly Transfer Film Dtf Printer With Oven Dryer A3 Dtf Machine For T-shirt All Fabric Application For Commercial After-sale Service Shop's Three Guarantees Weight 22kg Internal Memory None Voltage 100-240v Dot Matrix Printer Type Universal Ticket Printer Consumable Type Separate Toner Max. Resolution 2880*1440dpi Color Print Speed 25ppm Black Print Speed 23ppm Use Dtf Printer For Clothes Print Speed 22ppm Double-sided Printing No Supports Network Printing Wired/wireless Paper Feed Mode Automatic And Manual Max Paper Size A3 Type Inkjet Printer Interface Type Usb Certification Ce,weee Type A3 Dtf Printer Bundle Color Cmykww Paper Pet Film Ink Dtf Ink Print Head For Epson L1800 Application T-shirt ,textile Usage T-shirt Printing Machine Feature Dtf Printer A3 L1800 Complete Set 110,502.00 45 Calendar Days Upon Receipt Of Notice To Proceed (ntp) 1 Unit A1 Printer (594 X 841 Mm) Inkjet, Refillable Tank Print Speed, Maximum: 35 Sec/page On D, 68 D Prints Per Hour Resolution (color): Up To 2400 X 1200 Optimized Dpi Print Technology: Hp Thermal Inkjet / Number Of Print Cartridges: 4 (c, M, Y, K) Cartridge Used: Hp 712 Ink Cartridges / Weight: 47.4 Lb Connectivity: Gigabit Ethernet (1000base-t), Hi-speed Usb 2.0, Wi-fi 802.11a/b/g/n, Wi-fi Direct Memory: 512 Mb/ Media Sizes: 11 To 24 In / Dimensions (w X D X H): 39.9 X 17.3 X 11.2 In With Ink Catridge: 2x 80ml Black, 1x 29ml Cyan, 1x29ml Magenta & 1x29ml Yellow / Stand 98,000.00 4 Units 75" Smart Screen Information Monitor W/video Wall Controller, Cables, Ups And Portable Steel Stand Quad Core Processor 4k Thinq Ai Wifi And Bluetooth Connectivity / True Cinema Experience Ips, Led Or Oled / Ultra Surround Low Input Lag/ Webos, Android Or Tizen 300-400watts ( 259,000.00) 64,750.00/ Unit 5 Sets Validators Aio Desktop Set Specifications Desktop Aio 2xtwo Units Processor: Intel Core I3-i7 Operating System: Windows 11 Home, 64bit English Display: 24" Fhd (1920 X 1080) Memory: 8gb, Ddrfourthree Mhz, Dual-channel, Storage: Onetwoeightto256 Ssd Type-a Usb 3.2 Gen 1 Port, With Powershare Hdmi 2.1 Output Port, Power/dc-in Port Type-a Usb 3.2 Gen 1 Port, With Powershare Microsd Card Slot, Mini Display Port 1.4 Accesories: Wireless Mouse, Backpack Power: 6-cell Lithium Ion (86 Whr) Battery And Battery Charger Maximum Weight: 1.69 Kgs (5.93lbs) With 200w Bluetooth Speaker, Mouse Pad And 600w Uninterrupted Power Supply Ups. (280,000.00) 56,000.00/ Unit 1 Unit Digital Receiver Wireless Gooseneck Conference Microphone System Micwl Digital Receiver Wireless Gooseneck Conference Microphone System A10m-a103 President And Delegate Desktop Mic Unit Polar Patterns Omnidirectional Package Yes Communication Wired Set Type Multi-microphone Kits Transducer Condenser Microphone Use Conference Microphone Style Gooseneck Microphone Brand Name Micwl Model Number A10m-a103-t60 Description 128,100.00 2 Units Interactive Georeferencing Control Panel Operating System Windows 11 Home Processor Cpu:amd Ryzen™ Z1 Extreme Processor ("zen4" Architecture With 4nm Process, 8-core /16-threads, 24mb Total Cache, Up To 5.10 Ghz Boost) Gpu:amd Radeon™ Graphics (amd Rdna™ 3, 12 Cus, Up To 2.7 Ghz, Up To 8.6 Teraflops) Tdp: 9-30w Display 7-inch Fhd (1920 X 1080) 16:9 Ips-level Glossy Display Srgb:100% Adobe:75.35% Gorilla® Glass Dxc Gorilla® Glass Victus™ Touch Screen (10-point Multi-touch) Refresh Rate:120hz Response Time:7ms Brightness:500nits Freesync Premium Memory 16gb Lpddr5 On Board (6400mt/s Dual Channel) Storage 512gb Pcie® 4.0 Nvme™ M.2 Ssd (2230) I/o Ports 1x 3.5mm Combo Audio Jack 1x Rog Xg Mobile Interface And Usb Type-c Combo Port (with Usb 3.2 Gen2, Support Displayport™ 1.4) 1x Uhs-ii Microsd Card Reader (supports Sd, Sdxc And Sdhc) Control And Input A B X Y Buttons D-pad L & R Hall Effect Analog Triggers L & R Bumpers View Button Menu Button Command Center Button Armoury Crate Button 2 X Assignable Grip Buttons Thumbsticks: 2 X Full-size Analog Sticks Haptics: Hd Haptics Gyro:6-axis Imu Audio Ai Noise-canceling Technology Hi-res Certification (for Headphone) Dolby Atmos Built-in Array Microphone 2-speaker System With Smart Amplifier Technology Network And Communication Wi-fi 6e(802.11ax) (triple Band) 2*2 + Bluetooth® 5.2 (*bluetooth® Version May Change With Os Version Different.) Battery 40whrs, 4s1p, 4-cell Li-ion Power Supply Type-c, 65w Ac Adapter, Output : 20v Dc, 3.25a, 65w, Input: 100~240v Ac 50/ 60hz Universal Aura Sync Yes Weight 608 G Dimensions (w X D X H) 28.0 X 11.1 X 2.12 ~ 3.24 Cm (11.02" X 4.37" X 0.83" ~ 1.28") (132,000.00) 66,000.00/ Unit 1 Unit Geospatial Processing Mobile Pc Processor: 13th Generation Intel Core I9/i7 (14-core/20-thread, 24mb L3 Cache, Up To 4.7ghz Max Turbo Frequency) Operating System: Windows 11 Home, 64bit English Display: 17.3" Fhd (1920 X 1080) 360hz 1ms With Comfortview Plus, Nvidia G-sync And Advanced Optimus Technology: Advanced Ufolienware Cryo-tech Memory: 16gb, Ddr5, 4800 Mhz, Dual-channel Hard Drive: 1tb, M.2, Pcie Nvme, Ssd Color: Lunar Light Keystrokes: Ufolienware Series Thin Keyboard Form Factor: Portable Mobility Ports And Slots: Type-c Thunderbolt4 / Usb 3.2 Gen Port, With Power Delivery (5v/3a) Type-a Usb 3.2 Gen 1 Port, With Powershare Rj-45 Killer Ethernet E3100 2.5g Port Type-c Usb 3.2 Gen 2 Port, Power Delivery(5v/3a) Hdmi 2.1 Output Port, Power/dc-in Port Type-a Usb 3.2 Gen 1 Port, With Powershare Microsd Card Slot, Mini Display Port 1.4 Accesories: Wireless Mouse, Ufolienware 7.1, Vi Backpack Power: 6-cell Lithium Ion (86 Whr) Battery And Battery Charger Maximum Weight: 2.69 Kgs (5.93lbs) 190,000.00 4 Units Georeferencing Laptop Amd Ryzen™ 7 8845hs Processor (3.80 Ghz Up To 5.10 Ghz) Operating System Windows 11 Home 64 Single Language Graphic Card Nvidia® Geforce Rtx™ 4060 Laptop Gpu 8gb Gddr6 Memory 16 Gb Ddr5-5600mhz (sodimm) Storage 512 Gb Ssd M.2 2280 Pcie Gen4 Tlc Display 16" Wqxga (2560 X 1600), Ips, Anti-glare, Non- Touch, 100%srgb, 350 Nits, 165hz, Narrow Bezel, Low Blue Light Camera 1080p Fhd With Dual Microphone Battery 4 Cell Li-polymer 80wh Ac Adapter / Power Supply 230w Slim 3pin Ac Adapter - Us Keyboard White Backlit, Black - English Wlan Wi-fi 6e 2x2 Ax & Bluetooth® 5.1 Or Above Warranty 1 Year Legion Ultimate Support Color Luna Grey Part Number: 83dhcto1wwph1 (320,000.00) 80,000.00/unit 4 Set Encoding Laptop Set Specifications Laptop Three Segment Module Quantity Processor: Intel N4120 Operating System: Windows 11 Home, 64bit English Display: 15.6" Fhd (1920 X 1080) Memory: 4gb, Ddr4, 4800 Mhz, Dual-channel, Hard Drive: 256 Ssd Form Factor: Portable Mobility Type-a Usb 3.2 Gen 1 Port, With Powershare Hdmi 2.1 Output Port, Power/dc-in Port Type-a Usb 3.2 Gen 1 Port, With Powershare Microsd Card Slot, Mini Display Port 1.4 Accesories: Wireless Mouse, Backpack Power: 6-cell Lithium Ion (86 Whr) Battery And Battery Charger Maximum Weight: 1.69 Kgs (5.93lbs) With 200w Bluetooth Speaker And Mouse Pad (280,000.00) 70,000.00/unit 1 Set Plotter Printer With Cartridge Ink Designjet 36-inch Compact Large Format With Catruadge Ink Specifications - Ideal For: Technical Line Drawings, Renders Requiring Precise, Digital Blueprints, Accurate Line-quality And Crisp Text, Posters, And Maps. This Printer Is Popular Among Architects, Engineers, And Construction Professionals. - Media Sizes: Up To 24-inch Wide Media Rolls (large Format), And Up To 13-inch By 19-inch Sheets (wide Format) Using The Optional Automatic Sheet Feeder Accessory. - Media Handling: Sheet Feed, Roll Feed, Automatic Horizontal Cutter. - 1-click Printing From Anywhere: Save Time With The World's Easiest Job Submission Tool - Hp Click. Print Multiple Files In As Little As One Click. Manage Your Large Format Printing And Printer Virtually Anywhere And Anytime With The Hp Smart App, From Your Smartphone, Tablet, Or Desktop Computer. - Connectivity: Gigabit Ethernet (1000base-t), Hi- Speed Usb 2.0, Wi-fi 802.11. - Print Speeds & Ram: Up To 30 Seconds Per Page On A1/d Size, 76 A1/d Size Prints Per Hour. 500mb Memory. - Simple & Cost Efficient: Print Easily And Affordably With The World's Smallest Plotter Printers With Modern Office Design. Impressive Simplicity Helps You Save Time And Reduces Waste. Use Up To 95% Less Ink For Routine Maintenance Vs. Competitor Plotter Printers. Be Efficient And Productive From Job Prep To Final Print. - Software: Hp Click, Hp Smart App (for Printing From Tablets & Smartphones), Hp Print Preview For Windows, Hp Easy Start, Hp Designjet Utility For Windows, Hp Support Assistant. - Hp Designjet Ink Cartridges That Work With This Printer: Hp 712 29-ml Cyan (3ed67a), Hp 712 29- Ml Magenta (3ed68a), Hp 712 29-ml Yellow (3ed69a), Hp 712b 38-ml Black (3ed28a), Hp 712b 80-ml Black (3ed29a). Hp 713 Designjet Printhead (3ed58a). 190,000.00 4 Unit Interactive Dashboard 75" Touch Screen Display Specifications Display Size: 75" Resolution: 1920x1080 (rgb) Magic Mouse (with Voice Control) Thinq Ai, Works With Alexa Voice Control Dolby Audio Hdr Certified Improved Upscaling Motion Estimation Motion Compensation Digital Tv Miracast 5g Smart Save Energy Content Store Web Browser Shortcut Keys (412,000.00) 103,000.00/unit 10 Units Kobo Collection Equipment Specifications Design" Ipx4 Resistance Protects Against Water Splashing From All Angles. Even If It Is Water -resistant, This Is Unable To Guarantee Damage Prevention If Used Under Extreme Conditions. Operating System Processor: Qualcomm Snapdragon 8 Gen 3, Sm8650, Qcta-core Cpus, 3.3ghz Qualcomm Adreno 750 Memory: Lpddr5 16gb Storage: Ufs3.1 512gb Display: 6.78" 20.4:9 (2448 X 1080) 165hz / 1ms Samsung Amoled. Corning® Gorilla® Glass Victus. Delta-e < 1 Rear Camera: Main Camera: Sony® Flagship Imx766 50 Mp Image Sensor - 1/1.56” Large Sensor Size, 1 Μm Pixel Size. F1.9 Aperture. Front Camera: 12 Mp. 27.5mm Equivalent Focal Length In 35mm Film Camera Navigation" Gnss Support Gps (l1/l5), Glonass (l1), Galileo (e1/e5a), Beidou(b1i/b1c/b2a), Qzss (l1/l5) And Navic Sensor: In-display Fingerprint Sensor, Face Recognition, Accelerometer, E-compass, Gyroscope, Proximity Sensor, Ambient-light Sensor, Ultrasonic Airtrigger 6 And Grip Press Battery: Equivalent 6000 Mah (typical) High- Capacity Battery, Supports Quick Charge 5.0 And Pd Charging Power Adapter: Usb Power Adapter (65-watt) • Output: 3.3-21v 3.25a, Supports Up To 65w Qc5.0 / Pd 3.0 / Direct Charge Adapter 𝗗𝗜𝗠𝗘𝗡𝗦𝗜𝗢𝗡𝗦 • Weight And Dimension • 239g, • 173 X 77 X 10.4 Mm (550,000.00) 55,000.00/unit 2 Sets 1 Set Lower Earth Orbit Internet Device With Subscription "antenna Specifications: Type: Electronic Phased Array Orientation: Motorized Self Orienting Environmental Rating: Ip54 Operating Temperature -30°c To 50°c (-22°f To 122°f) Field Of View 100° Average Power Usage 50-75w Indoor Wi-fi Specifications: Wi-fi Technology: Ieee 802.11a/b/g/n/ac Standards Chipset: Wi-fi 5 Radio Dual Band - 3 X 3 Mimo Security: Wpa2 Environmental Rating: Ip54, Configured For Indoor Use Range Up To 185m² (2000sqft) Operating Temperature: -30°c To 50°c (-22°f To 122°f) With Ethernet Accessory Inclusion Of 10 Months Subscription" Rapid Aerial Monitoring And Assessment Mini Uav Specifications 48mp, 1/1.3" Cmos Sensor 24mm (equiv.) Lens With 82.1º Fov And A Fixed F1.7 Aperture 4k/60p Video: Up To 4x Digital Zoom H.264 And H.265 Recording At 150 Mbps D-cinelike And Normal Video Profiles Raw And Jpeg Image Capture, Apas And Active Track 4.0 Ocusync 3.0 (o3) 1080p/30p Image Transmission 12 Km Range Three-way Obstacle Avoidance Front, Back, Bottom Mastershots: Cinematic Capture Mode 47-minute Flight Time W/ Intelligent Aeril Battery X3 Under 250g At Take It Off With Standard Battery Transmitter:rc-n1 Remote Controller With Oled Screen Bitrate Tx: Video Bitrate 18mbps Delivered At An Ultra-low Latency 120ms With Microsd Card 64gb Uhs X10 Peripherals: 3,380mah, 11.4v Battery For Mvcpro Platinum 2x (106,600.00) 53,300.00/unit 75,000.00 2 Sets 3 Units Georeferencing Rendering Equipment Cpu: X86-64-ryzen Zen 2 8 Cores / 16 Threads Variable Frequency, Up To 3.5 Ghz Gpu Amd Radeon™ Rdna 2-based Graphics Engine Ray Tracing Acceleration Variable Frequency, Up To 2.23 Ghz 10tflops System Memory, Gddr6 16gb 448gb/s Bandwidth Ssd: 825gb, 5.5gb/s Read Bandwidth (raw) Optical Drive: Ultra Hd Blu-ray (66g/100g) Bd-rom (25g/50g) ~8xcav Bd-r/re (25g/50g) ~8xcav Dvd ~3.2xclv Ps5 Disc Ultra Hd Blu-ray, 100gb/disc Video Out: Hdmi™ Out Port Support Of 4k 120hz Tvs, 8k Tvs, Vrr Audio: “tempest” 3d Audiotec Dimensions 5: Approx. 390mm X 104mm X 260mm (width X Height X Depth)largest Weight : 4.5kg Power : 350w Input/output: Usb Type-a Port (usb 10gbps) X2 Usb Type-c® Port (usb 10gbps) Networking: Ethernet (10base-t, 100base-tx, 1000base-t), Ieee 802.11 A/b/g/n/ac/ax, Bluetooth® 5.1 Remote Transmitter Controller Wireless 2x, And 3x Optical Rendering Disc Titles Portable Intelligent Energy Transformation Equipment 2400w Expandable Capacity Lithium Sodium Phosphate/lipo Battery/ Lion Multiple Charging Methods Ac-dc Output Weight: 22-24kg Warranty: 3-10 Years Supplier And Global (130,000.00) 65,000.00/unit (249,798.00) 83,266.00/unit Bidders Should Have Completed, Within Two (2) Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii (instructions To Bidders). 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra No. 5183. 4. Prospective Bidders May Obtain Further Information From Da Rfo 5, Bac Secretariat Office, San Agustin, Pili, Camarines Sur And Inspect The Bidding Documents At The Address Given Below During Mondays – Fridays, 8:00 Am To 5:00 Pm Except For Holidays, Saturdays And Sundays. 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On November 27 - December 18, 2024 (9:00 Am) From The Given Address And Website(s)below And Upon Payment Of The Applicable Fee For The Bidding Documents, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Of: Description Abc (php) (inclusive Of Vat) Cost/price Of Bid Documents (cash Payment Only)(php Supply And Delivery Of Various Co Ict Equipment ₱5,000.00 A3 Dtf Printer Bundle For Epson L1800 Directly Transfer Film Dtf Printer With Oven Dryer A3 Dtf Machine For T-shirt All Fabric 110,502.00 A1 Printer (594 X 841 Mm) Inkjet, Refillable Tank 98,000.00 75" Smart Screen Information Monitor W/ Video Wall Controller, Cables, Ups And Portable Steel Stand 259,000.00 Validators Aio Desktop Set 280,000.00 Digital Receiver Wireless Gooseneck Conference Microphone System 128,100.00 Interactive Georeferencing Control Panel 132,000.00 Geospatial Processing Mobile Pc 190,000.00 Georeferencing Laptop 320,000.00 Encoding Laptop Set 280,000.00 Plotter Printer With Cartridge Ink 190,000.00 Interactive Dashboard 75" Touch Screen Display 412,000.00 Kobo Collection Equipment 550,000.00 Lower Earth Orbit Internet Device With Subscription 106,600.00 Rapid Aerial Monitoring And Assessment Mini Uav 75,000.00 Georeferencing Rendering Equipment 130,000.00 Portable Intelligent Energy Transformation Equipment 249,798.00 Total ₱3,511,000.00 The Procuring Entity Shall Allow The Bidder To Present Its Proof Of Payment For The Fees. 6. The Da Rfo 5 Will Hold A Pre-bid Conference On December 6, 2024; 10:00 Am At 3rd Flr. Training Hall, Operations Bldg., Da Rfo-5, San Agustin, Pili, Camarines Sur, Which Shall Be Open To Prospective Bidders. 7. Bids Must Be Duly Received By The Bac Secretariat Through Manual Submission At The Office Address Indicated Below, On Or Before December 18, 2024; 9:00 Am. Late Bids Shall Not Be Accepted. 8. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 14. 9. Bid Opening Shall Be On December 18, 2024; 10:00 Am Onwards At The Given Address Below 3rd Flr. Training Hall, Operations Bldg., Da Rfo-5, San Agustin, Pili, Camarines Sur. Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend The Activity. 10. In Case Of A Tie Bid, The Bac Will Conduct The Guidelines On The Use Of Non-discretionary/non-discriminatory Selection Criteria As Tie-breaking Method Thru Draw Lots In Case Of Two Or More Bidders Have Been Post-qualified Determined As The Bidder Having The Lowest Calculated And Responsive Bidder (lcrb) (gppb Circular No. 06-2005). 11. The Da Rfo 5 Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections 35.6 And 41 Of The 2016 Revised Irr Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 12. For Further Information, Please Refer To: Bac Secretariat Office Department Of Agriculture, Regional Field Office No. 5 San Agustin, Pili, Camarines Sur 4418 Email Address: Bacrfo5@gmail.com For Downloading Of Bidding Documents: Https://bicol.da.gov.ph November 25, 2024, San Agustin, Pili, Camarines Sur Lorenzo L. Alvina Oic, Rtd For Research And Regulations Bac Chairperson
Closing Date18 Dec 2024
Tender AmountPHP 3.5 Million (USD 59.4 K)

Township of Divišov Tender

Others...+2Civil And Construction, Civil Works Others
Corrigendum : Closing Date Modified
Czech Republic
Details: The subject of the performance of the public contract is the revitalization of the square in Divišov, which consists in the reconstruction of the public space with the new construction of the shelter, retaining walls and in the vegetation management of the entire space. The implementation also includes the implementation of engineering networks (a new spine of rainwater drainage along the northern front of Horního and Tyršová Náměstí, which drains the relevant paved areas with street drains or gutters; a new public lighting system, including new cable routes; a ceremonial lighting system for the church, the Fallen Monument, and the historical well Electrification of Tyršov Square Square For The Purposes Of Municipal Events (drawer cabinets); Water Supply To The Planned Drinking Water And Hydrant On Tyršov Square; Repair Of Well On Tyršov Square.
Closing Date9 Dec 2024
Tender AmountCZK 71.4 Million (USD 2.9 Million)
5091-5100 of 5144 active Tenders