Battery Tenders
Battery Tenders
Offizielle Bezeichnung Landesbetrieb Bau Und Immobilien Hessen Niederlassung Mitte Zentrale Vergabe Tender
Civil And Construction...+1Others
Germany
Closing Date31 Jan 2025
Tender AmountRefer Documents
Description: Public tender Vob/a Demolition and dismantling work (din 18 459); Floor covering work (din 18 365); Screed work (din 18 353); Tiling and panel work (din 18 352); Scaffolding work (din 18 451); Painting and varnishing work - coatings (din 18 363); Bricklaying (din 18 330); Plastering and stucco work (din 18 350); Wallpapering (din 18 366); Drywall work (din 18 340); Carpentry and timber construction work (DIN 18 334); Demolition and dismantling work (DIN 18 459); Construction site equipment: Construction site equipment including mobile crane 1 piece; Construction fence, wire mesh with privacy net 250 m; Construction road + container parking areas, mineral mixture 200 m²; Lawn finishing care 350 m²; Work protection: 1-chamber lock 12 pieces; Partitioning, fiber-tight and stable 250 m²; Material airlock and personnel airlock; Scaffolding work: Facade/roof scaffolding, 2 kN/m², W06 2300 m²; Provision for scaffolding 78200 m²wo; Dismantling of contaminated building materials: Demolition of asbestos cement ventilation ducts 12 pieces; Demolition of asbestos-containing flexible panels + adhesive 215 m²; Demolition of KMF impact sound insulation, D=15mm 1250 m²; Demolition of PK-containing release paper 1100 m²; Demolition work: Demolition of tiles 750 m²; Demolition of PVC floor covering 900 m²; Demolition of cement screed 360 m²; Demolition of interior wall plaster 4200 m²; Demolition of ceiling plaster + reed mats 1590 m²; Demolition of interior doors + frames 95 pcs.; Shell work: Making / widening door openings 31 pcs.; Making masonry pillars 19 pcs.; Making foundations for external staircase 1 m³; Core drilling 138 pcs.; Roofing work: Installing line ventilators in interlocking tile roof 15 pcs.; Sun protection: Venetian blinds for windows 98 pcs.; Locksmith: External staircase 1 pc.; Adjusting balcony railings 15 pcs.; plastering work: lime cement ceiling plaster 462 m²; gypsum ceiling plaster 1250 m²; lime cement wall plaster 152 m²; gypsum wall plaster 1670 m²; screed work: quick cement screed, D= 40-45 mm 1230 m²; floor covering work: linoleum covering 1160 m²; drywall work: dry screed/rock wool insulation panels D= 100 mm 609 m²; plasterboard assembly walls 469 m²; plasterboard installation walls 116 m²; plasterboard sub-ceiling 832 m²; plasterboard suspended ceiling 340 m²; tiling and natural stone work: floor tiles 84 m²; wall tiles 53 m²; carpentry work: tea kitchens 2 pcs.; interior doors office doors 23 pcs.; Damp room doors 14 pieces; metalwork: aluminum frame doors 16 pieces; sheet steel doors including frames 11 pieces; painting work: glass fabric wallpaper + emulsion paint walls 2800 m²; coating suspended plasterboard ceilings 1171 m²; coating steel perimeter frames 44 pieces; coating sheet steel doors with frames 10 pieces; overhaul coatings walls + ceilings 940 m²; industrial floor coating epoxy resin 290 m²; building cleaning work: intermediate and final cleaning 1600 m²; locking system: BKS profile double cylinder 49 pieces; digital double knob cylinder 27 pieces; transponder 100 pieces; panic lock 34 pieces; access control smart relay 11 pieces, programming device + locking plan creation HLS + building automation: -1. And 2nd floor (the ground floor was already prepared in 2018): Dismantling of the complete sanitary installation from the equipment standard for apartments and equipping the building with sanitary facilities for an office building, consisting of dismantling 31 hand basins, 21 toilets/urinals, 12 shower trays and 6 bathtubs with vanity units, shower partitions and small parts, equipping the new toilet areas with 9 hand basins, 11 toilets, 2 urinals, 1 shower tray, 2 sinks, each with support frames, instantaneous water heaters and sanitary accessories and installations for two kitchen sinks, 150 m of PP+SML waste water pipes, 200 m of stainless steel drinking water pipes with press connections and thermal insulation, 16 fire extinguishers with wall boxes, dry riser with three feed-in and 15 extraction points with pipes. -approx. 40 new radiators with approx. 180 m of C-steel pipes. -12 fans for toilet exhaust air in accordance with DIN 18017-3 and one for battery room exhaust air with PPS pipes, four split air conditioning units. -Approx. 350 sprinkler heads, approx. 500 m of sprinkler pipes for a wet and a dry system, sprinkler distributor, a sprinkler station, nitrogen generator. -Building automation with simple monitoring tasks. Electrics: Installation cable NYM-J 3x2.5 mm² various. Installation types approx. 6,000 m, installation cable Nym-j 3x1.5 mm² approx. 3,500 m, cable halogen-free Nhxhx-j-fe180 up to 3x2.5 mm² approx. 2,000 m, installation cable E 30 up to 4x2x0.8 mm approx. 2,300 m, installation distributor 230 VI 250 A indoor installation wall mounting 8 pieces, circuit breaker 1-pole character b 16a 250 pieces, cable tray perforated steel strip galvanized H 60mm W up to 600 mm approx. 300 m, electrical installation duct device installation H/w 60/130mm plastic approx. 650 m, Bap-LED surface-mounted light 35W approx. 154 pieces, LED recessed downlight D=235mm, 16 W approx. 65 pcs., LED safety lights approx. 65 pcs., LED escape sign lights approx. 40 pcs., BMA signal generator optical flashing light approx. 100 pcs., loudspeaker for wall and ceiling mounting up to 2x6 W approx. 110 pcs., data cable Cat. 6a various installation types approx. 12,000 m, data connection box sym. Cat. 6a 2 ports approx. 170 pcs.
Caraga Regional Hospital Tender
Others
Philippines
Closing Date21 Jan 2025
Tender AmountPHP 4.8 Million (USD 82.7 K)
Details: Description Republic Of The Philippines Department Of Health Caraga Regional Hospital Surigao City Bids And Awards Committee Ooooooo --------------------------------------------------------------------------------------------------------------- @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ Invitation To Bid Ib No. 2024-01-21 (115) Supply And Delivery Of Various Equipment For Calibration Services - Rebid Abc: ₱ 4,800,000.00 ========================================================= 1. The Caraga Regional Hospital (crh), Through The Fy2024 Internally Generated Fund (igf) Intends To Apply The Sum Of Being The Approved Budget For The Contract (abc) Of Four Million Eight Hundred Thousand Pesos Only ( Php 4,800,000.00 ) Under The Contract For The Supply And Delivery Of Various Equipment For Calibration Services - Rebid. Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening And Items Below Are Subject For A Competitive Bidding, To Wit: Line Item Code Description Qty Unit Of Measure Unit Cost Total Cost 1 Defibrilator Measurement Analyzer 1 Unit 1,600,000.00 1,600,000.00 2 Electrosurgical Devices Analyzer 1 Unit 1,700,000.00 1,700,000.00 3 6 In 1 Patient Vital Signs Simulation/nibp, Spo2, Ecg, Temp, Ibp & Respiration Functionality Test 1 Unit 1,000,000.00 1,000,000.00 4 Gas Flow Equipment Analyzer 1 Unit 500,000.00 500,000.00 Grand Total ₱ 4,800,000.00 1. Defibrilator Measurement Analyzer Description Patient Category Defibrillators Analyzer Automates The Inspection And Preventive Maintenance Testing Of Defibrillators. They Need To Be Able To Test At Least Four Basic Defibrillator Performance Characteristics: Discharge Energy, Synchronized-mode Operation, Automated External Defibrillation, And Ecg Monitoring. Purpose Of Use Clinical Or Other Purpose Calibration Of Your Measuring Instruments Has Two Objectives. It Checks The Accuracy Of The Instrument And It Determines The Traceability Of The Measurement. In Practice, Calibration Also Includes Repair Of The Device If It Is Out Of Calibration. Clinical Department /ward Biomedical Department Technical Specifications Defib Measurement; Load Resistance; 45 -50ω +/- 1% No-inductive Range: 0-200 Joules Accuracy: ±1% Of Reading ±1 Joule Range (high): 200-600 Joules Accuracy: ±1% Of Reading ± 1 Joule Resolution: 0 - 0.1 Joule Voltage: 0 – 1000 To 5000 Volts Current: 0 – 50 To 100 Amps Sampling Rate: 200-250 Khz Sampling Frequency Maximum Pulse Width (capture Time): 5us – 100 To 120 Ms Clock Accuracy; 0.10s To 100+/_ 0.05s Aed Pulse Mode Waveforms; Normal Sinus Rhythm (nsr): 20 -300 Bpm, Amplitude 1.00mv (± 2%) Asystole (asys) Ventricular Fibrillation - Coarse (vfbc) 230-240 Bpm Amplitude) 1.00mv (± 2%) Ventricular Fibrillation – Fine (vfbf) 230-240 Bpm Amplitude) 1.00mv (± 2%) Monomorphic Ventricular Tachycardia(mvt0: 210 Bpm, 1.00mv (±2%) 200-210 Bpm, 1.00mv (±2% Atrial Fibrillation (afb): 20-300 Bpm, Amplitude 1.00mv (± 2%) Ecg Simulator: Ecg Simulation With High Level Output. Ecg Waveforms – Sinus: Normal Sinus Rhythm (nsr): 20 – 300 Bpm, Amplitude 0.50 – 5.00mv (± 2%) St Elevation (ste): 20 -300 Bpm, Amplitude 0.50 – 5.00mv (± 2%) St Depression (std): 20 -300 Bpm, Amplitude 0.50 – 5.00 Mv (±2%) Myocardial Infarction (mi): 20 – 300 Bpm, Amplitude 0.50 – 5.00mv (±2%) Tall T (tt): 20 300 Bpm, Amplitude 0.50 -5.00mv (±2%) Ecg Waveforms – Ventricular Arrhythmias: Premature Ventricular Contraction: 75-80 Bpm Intermittent (pvci): Amplitude 0.50 -5.00 – 5.00 Mv (±2%) Bigeminy (big): 75-80 Bpm, Amplitude 0.50 – 5.00mv (± 2%) Trigeminy (trig): 75-80 Bpm, Amplitude 0.50 – 5.00mv (± 2%) Ventricular Flutter (vflt): 230-240 Bpm, Amplitude 0.50 -5.00mv (± 2%)) Ventricular Fibrillation – Coarse (vfbc); 23-=240 Bpm, Amplitude 0.50 -5.00mv) Ventricular Fibrillation – Fine (vfbf): 230-240 Bpm, Amplitude 0.50 – 5.00mv (± 2%)) Monomorphic Ventricular Tachycardia (mvt): 200-210 Amplitude 0.50 – 5.00mv (±2% Right-focal Premature Ventricular Contraction (rfpvc) : 70-80 Bpm, Amplitude 0.50 -5.00mv (±2%)) Ecg Waveforms – Atrial Conduction Arrhymias: First Degree Av Block (favb): 70-80 Bpm, Amplitude 0.50 – 5.00mv (± 2%) Second Degree Av Block : 70-80 Bpm - Mobitz I (sav_ Mi): Amplitude 0.50 -5.00 Mv (± 2%) Second Degree Av Block: 70-80 Bpm) - Mobitz Ii (savb_mii): Amplitude 0.50 -5.00mv (±2%) Third Degree Av Block (tavb): 45-50 Bpm, Amplitude 0.50 -5.00mv (±2%)) Ecg Waveforms – Atrial Arrhythmias: Sinus Arrhythmias (sar): 20 -300 Bpm, Amplitude 0.50 -5.00 Mv (±2%) Missing Beat (mb): 20 - 300 Bpm, Amplitude 0.50 -5.00mv (±2%) Atrial Flutter (aflt): 250-300 Bpm, Amplitude 0.50 -5.00 Mv (±2%) Atrial Fibrillation (afb); 20 - 300 Bpm, Amplitude 0.50 -5.00 Mv (±2%) Paroxysmal Atrial Tachycardia (pat): 170-180 Bpm, Amplitude 0.50 -5.00mv (±2%) Premature Junctional Contraction (pjc): 20 - 300 Bpm, Amplitude 0.50 -5.00mv (±2%) Ecg Pacer Waveforms: Synchronous Atrial (aai): 20 - 300 Bpm, Pulse Amplitude 0.50 5.00mv Pulse Width 0.1 – 2.0ms Asynchronous Astrial (aoo): 20 - 300bpm Pulse Amplitude 0.50 – 5.00mv Pulse Width 0.1 - 2.0ms Pacer (pcr); 20 – 300 Bpm Pulse Amplitude 0.50 – 5.00mv. Pulse Width 0.1 – 2.0ms Ventricular Pacer (vvi); 20 300 Bpm Pulse Amplitude 0.50 – 5.00mv Pulse Width 0.1 – 2.0ms Atrial & Ventricular Pacer (ddd): 20 - 300 Bpm Pulse Amplitude 0.50 – 5.00mv Pulse Width 0.1 – 2.0ms R-wave Detection (rwd): 20 -300 Bpm Pulse Amplitude 0.50 -5.00mv Ecg Performance Wave Forms: Sine (sine): 0.1 – 300hz 1.00 – 10.00 Mv Square (sq): 0.1 – 300hz 1.00 – 10.00 Mv Triangle (tri): 0.1 – 300hz 1.00 – 10.00 Mv Sawtooth (saw): 0.1 – 300hz 1.00 – 10.00 Mv Inverse Sawtooth (invsaw): 0.1 – 300hz 1.00 – 10.00 Mv Pulse (pulse): 0.1 – 300hz 0.50 – 5.00 Mv Ecg Noise Selection: Amplitude 0 – 10.00mv Frequency 50 - 60 Hz Ecg Accuracy: Rate: ± 1% Bpm Amplitude: ± 2% (la-ll). ± 10% (paddles) Lead Ii: 1 – 10 Mv (in Steps Of 0.5 Mv). Other Leads Are Proportional To Lead Ii By The Following Percentages; Lead I: 60% Lead Ii 100% Lead Iii: 40% Pacer Input: Fix Load: 40-50ω Accuracy: 1 % , Non-inductive Over Voltage Protection: 5000 Va (4500-5000) Variable Load: 50 -1600ω In 50ω Steps Accuracy: 1 % Non Inductive Pulse Rate: 5.0 – 800ppm Accuracy: +/- (0.5% Rdg + 0.1ppm) Heart Rate Selection: 20 - 300 Bpm Under And Overdrive: 85% (20 Bpm Min) And 115% (300bpm Max) Wave Form Selection: Nsr, Vfibc, Vfibf, Mvt, Afib, Missing Beat, R-wave Detection Pulse Current Amplitude: 5.00 – 200ma Accuracy: +/- (1% Rdg + 0.02ma) Current Measurement: Average (rms) Leading Edge, Trailing Edge, Peak ( The Highest During The Pulse ) Pulse Width: 1.00 – 100ms Accuracy: +/- (0.5% Rdg + 0.01ms) Pulse Energy: 1µj – 2.00j Accuracy: +/- 4% + 10µj Pacer Manufacturer Algorithms: Cu Medical, Ge, Hp,laerdal, Mindray, Philips, Physiocontrol, Schiller, Welchallyn, Zoll Pacer Refractory Periods: Refractory Period Test: 15 – 500ms (paced And Sensed) Accuracy; +/- 1ms Pacer Sensitivity Test: Wave Form, R Wave: Polarity Normal And Reversed Selectable Dynamic Sensitivity: 0.05mv -5.00mv In 50µv Steps Pacer Interference Test (immunity): Heart Rate: 20 -300 Bpm Frequency: 50 Or 60 Hz Noise Level In Mv: 0-15.0mv Operation: 9.2-9.6v/2300-2400mah Nickel Metal Hydride Battery Pack Battery Charge Time: 2-2.5 Hours Battery Capacity (fully Charged): 10-12 Hours Mains Supply: 110/230v Ac.: 50 To 60hz 35va Power Supply Storage Environment: - 15°c To 60°c Operating Condition: 0°c To 40°c Environment Protection: Ip 40 Communication: Usb Display: Lcd Colour Graphic Display ¼ Vga Memory: 80-100 Test Results Including Graphs) Impact Rating: 5j Technical Services As Follows: • System Warranty Must Be Five (5) Years • Calibration Of The Unit Must Be Performed After Installation With Certificate • Service Call Within 24 Hours Maximum And Must Have Repair Facility In Mindanao Area. • Preventive Maintenance For Every Quarter Until Warranty Expires. • Service Kits And Consumables To Be Included For One Year Use. • Supplier Must Deliver And Install The Unit Without Cost To The Owner Accessories, Consumables, Spare Parts, Other Components Accessories: • Aed Lead • Ecg Snap Adapter 10 Pack • Usb Cable • Test N Tag 2 Bluetooth Printer • Thermal Labels Rolls 5 Pack • Paddle Adaptor Box • Paddle Adaptor Box Lead (red) • Paddle Adaptor Box Lead (black) • Applied Part Adaptor 10 Pack • Carrying Bag • Manual Guide Training, Installation And Utilisation Pre-installation Requirements Supplier To Perform Installation, Safety And Operation Checks Before Handover. Requirements For Commissioning 1.local Clinical Staff To Affirm Completion Of Installation, 2. Calibration Certificate And Warranty Certificate 3. The Supplier Must Have A Track Record/history/experience For Having A Calibration Center Within The Philippines For Assurance Of Being A Biomedical Company. 4. The Supplier Must Have A Certificate Of Being An Authorized Service Partner. 5. The Supplier Must Have A Branch Office In The Mindanao For Technical Support Purposes. 6. The Supplier Must Have A Local Business Permit For Services In The Mindanao Area. Training Of User/s 5 Days Training And Of User Biomed Engineer & Staff In Operation, Basic Maintenance And Documentation , Shall Be Provided User Care To Demonstrate The Proper Cleaning And Disinfection With Provision Of Printed Cards Or Tags Beside The Unit. Warranty And Maintenance Warranty • 5 Years For Parts And Labor • Cleaning And Maintenance Of Machine • Shall Have Spare Parts Availability Once The End User Needs It. Environmental Factors • Capable Of Being Stored Continuously In Ambient Temperature Of 0 To 50 Deg C And Relative Humidity Of 15 To 90%. • Capable Of Operating Continuously In Ambient Temperature Of 10 To 40 Deg C And Relative Humidity Of 15 To 90% Documentation Documentation Requirements User, Technical And Maintenance Manuals To Be Supplied In English Language. Service Manual In English. List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost. Certificate Of Calibration, Warranty And Inspection To Be Provided. Safety And Standards International Standards Risk Classification - Class B (ghtf Rule 11);class Ii (usa); Class Ii (eu, Japan, Canada And Australia) International Standards - Iso 13485, Fda, Ce. Delivery Period 90 Calendar Days From Receipt Of The Notice To Proceed Terms Of Payment Upon Full Delivery, Installed, Tested And Commissioned Service Center Must Have Service Center Within Caraga Regional, Cebu City, Cdo Or Davao City Post Qualification The Bidder Is Required To Send A Demo Unit To Caraga Regional Hospital. Failure To Comply With The Preferred Schedule Of The Procuring Entity For The Post Qualification Can Be A Ground For Disqualification. (no Extensions Allowed) 2. Electrosurgical Devices Analyzer Description Patient Category Electrosurgical Unit (esu) Analyzers Automate The Testing And Inspection Of The Output Circuits And Safety Feature Of Esus. They Perform Testing That Would Otherwise Require Several Other Pieces Of Equipment, As Well As Considerably More Time And Greater Technician Expertise. Purpose Of Use Clinical Or Other Purpose Calibration Of Your Measuring Instruments Has Two Objectives. It Checks The Accuracy Of The Instrument And It Determines The Traceability Of The Measurement. In Practice, Calibration Also Includes Repair Of The Device If It Is Out Of Calibration. Clinical Department /ward Biomedical Department Technical Specifications Power Measurement: True Rms Value Of Applied Waveform Power Rating: 0 – 800w (rms) Accuracy: ± ( 1w + 5% Of Reading) Duty Cycle: 80 – 100% Up To 60 Seconds Load Bank: 0 - 5115ω Resolution: 5 -7ω Voltage (peak): 5– 10kv (peak) - Closed Load Only Accuracy: ± (10% Of Reading + 15v) Voltage: 5 – 700v Rms Accuracy: ± (10% Of Reading + 5v) Current (rms): 0 – 6000 Ma With Load Banks 0 -8000ma External Load Test Accuracy: ± (2% Of Reading + 10ma) Crest Factor: 1.4 – 20 (vpeak / V Rms) Rms Bandwidth; Instrumentation Only: 30 Hz To 10mhz (-3 Db) With Loads: 30 Hz To 2.5 Mhz (-3 Db) Variable Loads: 5 - 5115ω Steps @ 5ω (1023 Steps) Accuracy: ± (1% + 0.5, 0.0ω Of Set Of Load) Load Array: Ceramic Resistors (non-inductive) Measurement Delay: Foot Switch Delay Selectable Between 300-5000ms (8-10m Seconds Resolution) Rf Leakage (high Frequency Leakage): Active: From Active Part To Earth Passive: From Plate – Receptacle – Earth Load: Variable See Power Measurement Fixed 2 X 200ω Accuracy: ± 1%, + 0.5, - 0.0 Ω Contact Quality Monitoring (cqm): Range: 0 -475ω Steps @ 1 Ω Steps Motor Driven Potentiometer Accuracy: ± 5-7% ± 1-2ω Alarm Register: High And Low Manual Confirmation Ranging: Manual Or Automatic Output Connectors: Remote Foot Switch Control (cut): Yellow, Single Relay Contact Remote Foot Switch Control (coag): Blue, Single Relay Contact High Frequency Leakage: Through 4mm Sockets And Power Measurements Usb: Pc Download Oscilloscope Output: 0.5v/a, 100ma, Rf Current Minimum Input, Un-calibrated, Indication Only Isolation: 10kv Isolation Between Measurement Device And Enclosure Low Frequency Filter: 100hz Filter To Avoid Low-frequency Disturbance Or Interference General: Memory: 4000- 5000 Records (4mb) Output: Csv And Sss Format Dimensions: Not More Than 373mm X310mm X210mm Weight: 10-12kg / 22 Lbs Operating Temperature: 10°c - 40°c / 50°c / 32°f -122°f Main’s Power: 115/230v Ac + 10%; 48 To 66 Hz, 35 Va Fuses: 2x 1.6 A (t) Ceramic Standard Accessories: Mains Lead, Usb Lead, Calibration Certification Technical Services As Follows: • System Warranty Must Be Five (5) Years • Calibration Of The Unit Must Be Performed After Installation With Certificate • Service Call Within 24 Hours Maximum And Must Have Repair Facility In Mindanao Area. • Preventive Maintenance For Every Quarter Until Warranty Expires. • Service Kits And Consumables To Be Included For One Year Use. • Supplier Must Deliver And Install The Unit Without Cost To The Owner Accessories, Consumables, Spare Parts, Other Components Accessories: • Test Lead, Usb Lead • Cut/coag Control Interface Cables • Power Cord • Colored Sheathed Banana Set • Operator Cd • Manual • Carrying Bag Training, Installation And Utilisation Pre-installation Requirements • Supplier To Perform Installation, Safety And Operation Checks Before Handover. Requirements For Commissioning • Local Clinical Staff To Affirm Completion Of Installation, Calibration Certificate And Warranty Certificate • The Supplier Must Have A Track Record/history/experience For Having A Calibration Center Within The Philippines For Assurance Of Being A Biomedical Company. • The Supplier Must Have A Certificate Of Being An Authorized Service Partner. • The Supplier Must Have A Branch Office In The Mindanao For Technical Support Purposes. • The Supplier Must Have A Local Business Permit For Services In The Mindanao Area. Training Of User/s 5 Days Training Of User Biomed Engineer & Staff In Operation, Basic Maintenance And Documentation , Shall Be Provided User Care To Demonstrate The Proper Cleaning And Disinfection With Provision Of Printed Cards Or Tags Beside The Unit. Warranty And Maintenance Warranty • 5 Years For Parts And Labor • Cleaning And Maintenance Of Machine • Shall Have Spare Parts Availability Once The End User Needs It. Environmental Factors • Capable Of Being Stored Continuously In Ambient Temperature Of 0 To 50 Deg C And Relative Humidity Of 15 To 90%. • Capable Of Operating Continuously In Ambient Temperature Of 10 To 40 Deg C And Relative Humidity Of 15 To 90% Documentation Documentation Requirements User, Technical And Maintenance Manuals To Be Supplied In English Language. Service Manual In English. List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost. Certificate Of Calibration, Warranty And Inspection To Be Provided. Safety And Standards International Standards Risk Classification - Class B (ghtf Rule 11);class Ii (usa); Class Ii (eu, Japan, Canada And Australia) International Standards - Iso 13485, Fda, Ce. Delivery Period 90 Calendar Days From Receipt Of The Notice To Proceed Terms Of Payment Upon Full Delivery, Installed, Tested And Commissioned Service Center Must Have Service Center Within Caraga Regional, Cebu City, Cdo Or Davao City Post Qualification The Bidder Is Required To Send A Demo Unit To Caraga Regional Hospital. Failure To Comply With The Preferred Schedule Of The Procuring Entity For The Post Qualification Can Be A Ground For Disqualification. (no Extensions Allowed) 3. 6 In 1 Patient Vital Signs Simulation / Nibp, Spo2, Ecg, Temperature, Ibp, And Respiration Functionality Test. Description Patient Category A Medical Device Tester Is Responsible For Ensuring That Medical Devices Meet Quality And Safety Standards. They May Work With A Variety Of Devices, From Blood Pressure Monitors To Pacemakers Purpose Of Use Clinical Or Other Purpose Calibration Of Your Measuring Instruments Has Two Objectives. It Checks The Accuracy Of The Instrument And It Determines The Traceability Of The Measurement. In Practice, Calibration Also Includes Repair Of The Device If It Is Out Of Calibration. 6 In 1 Patient Vital Signs Simulation: • Nibp, Spo2, Ecg, Temperature, Ibp, And Respiration Functionality Test. Clinical Department /ward Biomedical Department Technical Specifications Detailed Requirements Displayed Parameters User Adjustable Settings Non-invasive Blood Pressure Simulation: Waveform: Oscillometric Pulse Volume: High, Medeum,low, Pediatric Heart Rate; 20-300bpm Integrated Pump; 0 To 350mmhg User Configuration Leak Test: User Configurable Between 0-350mmhg Chronometer; Configurable Up To 999 – 1100 Secs) Digital Manometer: 0-410mmhg Pressure Accuracy: +/- 0.5% Fs Pressure Unit: Mmhg, Inhg, Kg/cm2. Cmh20, Mbar, Psi, In H20 And Kpa Oxygen Saturation Simulation(puls-r): Range: 30 To 100% Repeatability; Positive/negative 5% Of Reading Between 30-59% Spo2 Positive/negative 3% Of Reading Between 60-89% Spo2 Positive/negative 1% Of Reading Between 90-100% Spo2 ( Accuracy Of Simulation When Used With The Corresponding R-curves Based In Using The Same Probe And Monitor Set Up . Note That Some Montor Type Might Not Be Able To Display Low Range Sats) Heart Rate: 30-300bpm Accuracy: Positive/negative 1bpm Compatibility: Beijing Choice, Criticare, Ge Tuffsat, Masimo, Mindray, Nellcor, Nellcor Oximas, Nihon Kohden, Nonin, Novametrix, Philips,/hp Ecg Arrhythmia Simulator: Simulation: 5 Lead Simulation Including High Level Output On Normal Sinus Rhythm (nsr), St Elevation, St Depression, Myocardial, Infarction, Tall T Heart Rate: 20-300bpm Accuracy: Positive/negative 1 Bpm Amplitudes; Lead Ii: 0.5 -5 Mv (in Steps Of 0.5 Mv). Other Leads Are Proportional To Lead Ii By The Following Percentage: Lead I : 60% Lead Ii : 100% Lead Iii : 40% Accuracy: Positive/negative 2% Connection High Level Ecg 3.5mm Jack Plug St Elevation /depression: Heart Rate: 20-300bpm Elevation %: 7%, 13%, 20% Elevation Slope: Positive, Negative, Flat Myocardial Infarction: Type: Ischemia, Injury, Infarction, Inferior Infarction Heart Rate: 20-300bpm Tall T: Heart Rate: 80 Bpm (ranges 75-80) T Wave Amplitude: 0-1.2mv (steps Of 0.1mv) Arrhythmia Waveforms (atrial); Simulation: 5 Lead Simulation Amplitudes: 0.5 / 1 / 1.5 / 2 / 2.5 / 3 / 3.5 / 4 / 4.5 / 5 Mv. Heart Rate ( When Applicable ) 20 – 300bpm Atrial: Sinus Arrhythmia (sa), Missing Beat, Atrial Flutter (aflt), Atrial Fibrillation (afb), Paroxysmal Atrial Tachycardia (pat), Junctional Premature Contraction. Atrial Conduction: First Degree Av Block, Second Degree Av Block – Mobitz I, Second Degree Av Block – Mobitz Ii, Third Degree Av Block, Right Bundle Branch Block (rbb), Left Bundle Branch Block (lbb), Left Anterior Hemiblock. Ventricular: Premature Ventricular Contraction – Intermittent Premature Ventricular Contraction – Continuous Bigeminy, Trigeminy, Ventricular Flutter (vflt), Ventricular Fibrillation Fine (vfbf), Ventricular Fibrillation Coarse ( Vfbc), Monomorphic Ventricular Tachycardia (mvt), Polymorphic Ventricular Tachycardia (pvt) Right Focal (pvc). Performance Waveforms: Shape: Sine, Square, Triangle Rate: 0.1 To 0.9hz (in Steps Of O.1hz) 1 To 100hz (in Steps Of 1hz) Amplitude: Lead Ii : 0.5-5 Mv (in Steps Of 0.5 Mv) Other Leads As Above Accuracy: 2% Shape: Pulse Rate: 20 Ms Pulse Duration, 4 Second Delay Amplitude: Lead Ii : 1 Mv. Other Leads As Above Accuracy: 2% Pacer Waveforms: Available: Synchronous Atrial, Asynchronous Atrial, Paver Only, Ventricular Pacer, Atrial & Ventricular Pacer. Qrs: 1mv Pacer Pulse Amplitude: 0.1-2mv Pacer Pulse Polarity: Positive/negative Pacer Pulse Width: 0.1-2ms R Wave Detection: Heart Rate: 70 Bpm R Wave Width; 10-120ms (steps Of 10ms) Temperature Simulation: Simulation; Ysi 400 / 700 Static Range; Preset At 25, 23, 37, And 41c Accuracy: ± 0.1c Default Setting: Ysi 400 37c Respiration Simulation: Rates; 5, 10, 15, 30, 60, 120, 180 Breaths Per Minute Base Resistance: 250, 500, 750, 1000 Ohms Accuracy: ± 10% Resistance Variation: 0.1, 0.5, 1.0, 1.5 Ohms Accuracy: ± 10% Default Setting: 15bpm / 250ω / 0.1ω Apnoea Simulation: 0-60 Seconds Duration 0-300seconds Interval Invasive Blood Pressure Simulation; Channels: 2 Channels Static: 0 To 300mmhg Dynamic: 0-300mmhg For Systolic 6 Diastolic Accuracy: ±1mmhg Excitation Voltage: 2 – 16v Impedance: 350ω Nominal Simulated Sensitivity: 5µv / V /mmhg Basic Specification: Operation; Battery Cell, In-site Charge Battery Charger: 100-240vac, 50/60hz Supply; 12 Vdc Centre Positive Battery Life: 8 Hours Standby Or A Maximum Of 200 Nibp Simulations Memory Capacity; Approx. 5, 000 Records Communication: Bluetooth Display: Monochrome, ¼ Vga Full Graphics Keypad: Alpha Numeric Weight: < 1.5 Kg, <3.5lbs Size (lxwxd): 250-270 X 100 To 110 Mm / 10.5 X 4 X3 Operating Environment: - 15° - + 60°c Environmental Protection: Ip 40 Puls-r: Compatibility Beijing Choice, Ge Tuffsat, Mindray, Nellcor Oximax, Nonin, Philips / Hp, Criticare, Masimo, Nellcor, Nihon Kohden, Novametrix Supported Default R-curves Heart Rating: 30 – 300bpm Accuracy Of Simulation When Used With The Corresponding R Curves: Resolution 1% Steps - Range 30-59% - Repeatability ± 5% 1% Steps -range 60 – 89% - Repeatability ±3 % 1% Steps -range 90 – 100% - Repeatability ±1% Technical Services As Follows: • System Warranty Must Be Five (5) Years • Calibration Of The Unit Must Be Performed After Installation With Certificate • Service Call Within 24 Hours Maximum And Must Have Repair Facility In Mindanao Area. • Preventive Maintenance For Every Quarter Until Warranty Expires. • Service Kits And Consumables To Be Included For One Year Use. • Supplier Must Deliver And Install The Unit Without Cost To The Owner Accessories, Consumables, Spare Parts, Other Components Accessories: • Ibp Connection Cable • Nibp Accessories • Temperature Connect Cables • Ecg Cables And Leads • Puls-r Universal Spo2 Simulation Finger Standard Accessories: • Carry Case • Nibp Tubing Kit • Ecg Adaptor Module And Snap-on Adaptors • Quick Start Guide • Power Supply Training, Installation And Utilisation Pre-installation Requirements Supplier To Perform Installation, Safety And Operation Checks Before Handover. Requirements For Commissioning 1. Local Clinical Staff To Affirm Completion Of Installation, 2. Calibration Certificate And Warranty Certificate 3. The Supplier Must Have A Track Record/history/experience For Having A Calibration Center Within The Philippines For Assurance Of Being A Biomedical Company. 4. The Supplier Must Have A Certificate Of Being An Authorized Service Partner. 5. The Supplier Must Have A Branch Office In The Mindanao For Technical Support Purposes. 6. The Supplier Must Have A Local Business Permit For Services In The Mindanao Area. Training Of User/s 5 Days Training Of User Biomed Engineer & Staff In Operation, Basic Maintenance And Documentation , Shall Be Provided User Care To Demonstrate The Proper Cleaning And Disinfection With Provision Of Printed Cards Or Tags Beside The Unit. Warranty And Maintenance Warranty • 5 Years For Parts And Labor • Cleaning And Maintenance Of Machine • Shall Have Spare Parts Availability Once The End User Needs It. Environmental Factors • Capable Of Being Stored Continuously In Ambient Temperature Of 0 To 50 Deg C And Relative Humidity Of 15 To 90%. • Capable Of Operating Continuously In Ambient Temperature Of 10 To 40 Deg C And Relative Humidity Of 15 To 90% Documentation Documentation Requirements User, Technical And Maintenance Manuals To Be Supplied In English Language. Service Manual In English. List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost. Certificate Of Calibration, Warranty And Inspection To Be Provided. Safety And Standards International Standards Risk Classification - Class B (ghtf Rule 11);class Ii (usa); Class Ii (eu, Japan, Canada And Australia) International Standards - Iso 13485, Fda, Ce. Delivery Period 90 Calendar Days From Receipt Of The Notice To Proceed Terms Of Payment Upon Full Delivery, Installed, Tested And Commissioned Service Center Must Have Service Center Within Caraga Regional, Cebu City, Cdo Or Davao City Post Qualification The Bidder Is Required To Send A Demo Unit To Caraga Regional Hospital. Failure To Comply With The Preferred Schedule Of The Procuring Entity For The Post Qualification Can Be A Ground For Disqualification. (no Extensions Allowed) 4. Gas Flow Equipment Analyzer Description Patient Category Test Gas Flow And Respiratory Medical Equipment Accurately, Including Ventilators, Flow Meters, Edoscopic Insufflators, Suction Devices, Pressure Gauge And Anaesthesia Machine, Especially When Accuracy Of Low Volume And Pressure Is Crucial. Purpose Of Use Clinical Or Other Purpose Calibration Of Your Measuring Instruments Has Two Objectives. It Checks The Accuracy Of The Instrument And It Determines The Traceability Of The Measurement. In Practice, Calibration Also Includes Repair Of The Device If It Is Out Of Calibration. 5 In 1 Gas Flow Equipment Analyzer • Ventilators, Flow Meters, Pressure Gauge, Suction Machine And Anesthesia Machine Clinical Department /ward Biomedical Department Technical Specifications Flow And Pressure Measurements: Flow: Range: Accuracy: Measuring Direction * Bidirectional Temperature Compensated * Automatic Or Manual Pressure Compensated *automatic Humidity Compensated *- Manually High Flow * ±300 L/min , * ±1.9% Or 0.1 L/min (for 10..40°c) Pressure: High Pressure (p High) * -1 – 9 Bar * ±0.5-1% °or ±6-7 Mbar Differential Pressure (p High): * ±180-200mbar * ±.05-0.75% Or ±0.5-0.1mbar Pressure In High Flow Channel: * - 55-150mbar * ±0.75% Or 0.1mbar Atmospheric Pressure: * 550-1150mbar * ±1% Or ± 5mbar Units: Flow: * L/min, L/s, Cfm, Ml/min, Ml/s Pressure: * Bar, Mbar, Cmh20, Inh20, Torr, Inhg, Hpa, Kpa, Mmhg, Psi Other Measurement: Oxygen; Concentration; * 0-50% * ±15 O2 Pressure Compensated; * ≤100-150mbar Temperature: In High Flow Channel: * 0-55°c * ±1.75% Or ±0.5% °c Co2: Concentration * 0-16 Vol% * ±(0.2vol% + 2% Of Reading) N2o: Concentration * 0-90 Vol% * ±(2% Vol% + 2% Of Reading) Hal, Iso,enf: Concentration * 0-8% Vol% * ±(0.15% + 5% Of Reading) Sev Concentration *1-10% Vol% * ±(0.15% Vol% +5% Of Reading) Des Concentration * 0-20 Vol% * ±(0.15 Vol% +55 Of Reading) Gas Type: * Air,o2, Air/o2, N2o, N2o/o2, He/o2, N2,c02, Gas Standards: * Atp, Atpd, Atps, Ap21, Stp, Stph, Btps, Btps-a, Btpd, Btpd-a, 0/1013, 20/981, 15/1013, 25/991, 20/1013, Ntpd, Ntps Ventilation Parameters: Breath Rate: Rate: * 1-980 Bpm * ±0.5 Bpm Or ±0.5-5% Or 2.0 Time Ti Te * 0.04 – 60 S * ±0.01-0.02 S Ratio I:e * 1:300-300:1 * ±2.5% * 0-90% * ±3-5% Breath Volumes V: * * ±2% Or 0.20ml (> 6 Sl/min) Vti,vte: * ±10l * ±2% Or ±2.20ml (>6 Sl/min) Minute Volume Vi, Ve: * 0-299sl/min * ±2.5% Pressure P Peak, P Mean, Peep, P Plateau, Ipap: * 2-150 Mbar * ±0.75% Or ±0.1mbar Peakflow Pf Insp1, Pf Xp : * ±300 Sl/min * ±1.9% Or ±0.1% Sl/min Compliance C Stat * 1-1000 Ml/mbar * ±3% Or ±1ml/mbar Trigger Adult, Pediatric, Hfo Ext. Trigger * Adult, Pediatric Hfo, Adjustable On Flow Or Pressure Curves With User Defined Limits General Information; Power: * 100-240vac, 50/60hz Battery * 3-5 Hours Power Consumption * 3-6 W Weight * 0.52-1kg Dimension ( W X D Xh) * 11.4x 7x 7.3cm Depends Of The Manufacturer) Data Storage * Internal And Micro Sd Display * Multi Touch (color) , Realtime Curves Interfaces * Rs-232, Usb , Ethernet, Can, Analog Out, Ttl, Wlan, Tsi4000 And Prima Protocool Calibration * Annually Condition Ambient Temperature * 20-40°c (*59-104°f) Condition Humidity * 20-90% R,h Technical Services As Follows: • System Warranty Must Be Five (5) Years • Calibration Of The Unit Must Be Performed After Installation With Certificate • Service Call Within 24 Hours Maximum And Must Have Repair Facility In Mindanao Area. • Preventive Maintenance For Every Quarter Until Warranty Expires. • Service Kits And Consumables To Be Included For One Year Use. • Supplier Must Deliver And Install The Unit Without Cost To The Owner Accessories, Consumables, Spare Parts, Other Components Accessories: • Stand • Smartlung Adult (1l) • Webserver Configurator And Monitoring • Flow Lab Software • Oxygen Sensor • Adapter Set • Laminar Flow Tube • Car Adapter • Micro Sd Memory Card • Protection Filter • Usb Cable • Ethernet Cable • Power Supply • Battery Pack • Usb Adapter • Manual • Protector • Carrying Bag Training, Installation And Utilisation Pre-installation Requirements Supplier To Perform Installation, Safety And Operation Checks Before Handover. Requirements For Commissioning 1. Local Clinical Staff To Affirm Completion Of Installation, Calibration Certificate And Warranty Certificate 2. The Supplier Must Have A Track Record/history/experienced For Having A Calibration Center Within The Philippines For Assurance Of Being A Biomedical Company. 3. The Supplier Must Have A Certificate Of Being An Authorized Service Partner. 4. The Supplier Must Have A Branch Office In The Mindanao For Technical Support Purposes. 5. The Supplier Must Have A Local Business Permit For Services In The Mindanao Area. Training Of User/s 5 Days Training Of User Biomed Engineer & Staff In Operation, Basic Maintenance And Documentation , Shall Be Provided User Care To Demonstrate The Proper Cleaning And Disinfection With Provision Of Printed Cards Or Tags Beside The Unit. Warranty And Maintenance Warranty • 5 Years For Parts And Labor • Cleaning And Maintenance Of Machine • Shall Have Spare Parts Availability Once The End User Needs It. Environmental Factors • Capable Of Being Stored Continuously In Ambient Temperature Of 0 To 50 Deg C And Relative Humidity Of 15 To 90%. • Capable Of Operating Continuously In Ambient Temperature Of 10 To 40 Deg C And Relative Humidity Of 15 To 90% Documentation Documentation Requirements User, Technical And Maintenance Manuals To Be Supplied In English Language. Service Manual In English. List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost. Certificate Of Calibration, Warranty And Inspection To Be Provided. Safety And Standards International Standards Risk Classification - Class B (ghtf Rule 11);class Ii (usa); Class Ii (eu, Japan, Canada And Australia) International Standards - Iso 13485, Fda, Ce. Delivery Period 90 Calendar Days From Receipt Of The Notice To Proceed Terms Of Payment Upon Full Delivery, Installed, Tested And Commissioned Service Center Must Have Service Center Within Caraga Regional, Cebu City, Cdo Or Davao City Post Qualification The Bidder Is Required To Send A Demo Unit To Caraga Regional Hospital. Failure To Comply With The Preferred Schedule Of The Procuring Entity For The Post Qualification Can Be A Ground For Disqualification. (no Extensions Allowed) This Procurement Is A Partial Bid Or Line Item Bid. Validity Of The Contract Without Prejudice To The Provision Of Applicable Laws, Rules And Guidelines, The Contract Shall Be Automatically Terminated Under The Following Conditions: A. When The Total Quantity Specified In The Contract Has Been Exhausted; Or B. For Any Justifiable Reason Ground Where The Contract Will Not Redound To The Benefit Of The Government Or There Is Violation Of The Contract. General Conditions All Other Rules Governing Contract Implementation And Termination Under Ra 9184 And Its Irr, And Relevant Procurement Policies Shall Be Applicable. Technical Specifications And Terms Of Reference Is Hereby Posted In Philgeps And Form An Integral Part Of This Invitation To Bid. 2. The Crh Now Invites Bids For The Procurement Of The Above-captioned Project. Delivery Of The Goods Is Required Within The Period Specified Under Section Vi (schedule Of Requirements). Bidders Should Have Completed, Within Two (2) Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. Section 23.4.1.3. (ra 9184) The Bidder Must Have Completed A Single Contract That Is Similar To This Project, Equivalent To At Least Fifty Percent (50%) Of The Abc. Slcc Must Be Within 2 Years From The Submission Of Bids. (based On The Completion Date). Slcc Shall Be The Same Or Similar In Nature, Which Shall Be Determined By The Bids And Awards Committee. For Procurement Where The Procuring Entity Has Determined, After The Conduct Of Market Research, That Imposition Of Either (a) Or (b) Will Likely Result To Failure Of Bidding Or Monopoly That Will Defeat The Purpose Of Public Bidding: The Bidder Should Comply With The Following Requirements: A. Completed At Least Two (2) Similar Contracts, The Aggregate Amount Of Which Should Be Equivalent To At Least Fifty Percent (50%) In The Case Of Non-expendable Supplies And Services Or Twenty-five Percent (25%) In The Case Of Expendable Supplies] Of The Abc For This Project; And B. The Largest Of These Similar Contracts Must Be Equivalent To At Least Half Of The Percentage Of The Abc As Required Above. 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Nondiscretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) 9184, Otherwise Known As The “government Procurement Reform Act”. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra 5183. 4. Interested Bidders May Obtain Further Information From The Bids And Awards Committee (bac) Secretariat, At Procurement Section, Caraga Regional Hospital, Surigao City And Inspect The Bidding Documents At The Address Given Above During 8:00 Am – 5:00 Pm, Monday To Friday. 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On December 10, 2024 – January 21, 2025 On Or Before 10:00 A.m. From The Address Above And Upon Payment Of The Applicable Fee For The Bidding Documents, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Specified Below: Bidding Schedule Pre-bidding Conference December 18, 2024 At 9:00 O’clock In The Morning Via Zoom Platform Link: Join Zoom Meeting Https://us06web.zoom.us/j/83066464127?pwd=umvcd4lcmrkaz6ldz2qhqbhw76cdzk.1 Meeting Id: 830 6646 4127 Passcode: 528376 Deadline Of Submission Of Bids January 21, 2025 At 10:00 A.m... Via Online And Submit Your Bidding Documents To This Email Address: Crhbac2020@gmail.com . Please Be Advised That Failure To Submit Bidding Documents To The Designated Official Email Address Will Result In Automatic Rejection And Disqualification. Opening Of Bids January 21, 2025 At 2:00 P.m. Via Zoom Platform. Join Zoom Meeting Https://us06web.zoom.us/j/85126317644?pwd=pqhrftd91zoxlr4ufcctyy7gtdz5qj.1 Meeting Id: 851 2631 7644 Passcode: 872092 Complete Philippine Bidding Documents Please Click The Link Below For The Complete Pbd: Https://drive.google.com/drive/folders/1enb1ofcvp2zs4qembcxjjpeilwkths5c?usp=sharing Payment Of Bidding Documents Php 5,000.00 It May Also Be Downloaded Free Of Charge From The Website Of The Philippine Government Electronic Procurement System (philgeps) And The Website Of The Procuring Entity, Provided That Bidders Shall Pay The Applicable Fee For The Bidding Documents Not Later Than The Submission Of Their Bids. The Following Phlippine Bidding Documents Can Be Accessed In The Philgeps, To Wit: A. Technical Specification / Terms Of Reference/ List Of Items B. Instruction To Bidders: B.1. Documents To Be Submitted (checklist- This Will Be Discussed During The Pre-bid Conference) B.2. Memorandum Of Undertaking – Provision Thereof Is Strictly Implemented C. Guidelines On The Conduct Of The Electronic Submission And Receipt Of Bids By The Procuring Entity – Caraga Regional Hospital (crh) D. Philippine Bidding Documents 6. The Crh Will Hold A Pre-bid Conference On The Above-mentioned Date, Time And Venue, Which Shall Be Opened To Prospective Bidders. The Pre-bidding Conference And Opening Of Bids Shall Be Conducted Through Videoconferencing, Webinar Or Virtual. Please Send Your Intent To Participate To Our Email Address As Provided Below. 7. Bids Must Be Duly Received By The Bac Secretariat At Via Designated Email On Or Before January 21, 2025 At 10:00 O’clock In The Morning. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 18. Bid Opening Shall Be On January 21, 2025 At 2:00 O’clock In The Afternoon At The Bac Conference Room, Beside Procurement Office, Caraga Regional Hospital, Rizal Street, Surigao City As Virtual / Electronic Bidding Via Zoom Platform. Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend At The Address Above. Late Bids Shall Not Be Accepted Under Any Circumstances May It Cause. 8. Furthermore, The Standard Philippine Bidding Document (pbd) Is Form And Part Of This Invitation In Accordance To Ra 9184 And Other Applicable Laws, Rules And Policy. 9. The Crh Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Section 41 Of Ra 9184 And Its Irr, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 10. The Opening And Receipt Of Bids Is Strictly Implemented Through Electronic Submission. Given The Covid-19 Pandemic, Procurement Activity Has Been Expedient And One Of This Is The Conduct Of Electronic Submission Of Bids. The Crh Thru The Bids And Awards Committee (bac) Has Submitted Certification, Certified By The Highest Official Managing The Information Technology, Describing The Electronic System Or Procedure To Be Used By The Crh For The Electronic Submission And Receipts Of Bids And A Statement That The Same Is Compliant With The Gppb Resolution No. 12-2020 Requirements. 11. Bidding Documents Shall Be Emailed To This Email Address, With Activated Password To: Crhbac2020@gmail.com. You May Deposit On Line For The Payment Of The Bidding Documents To This Account Below: Bank Name: Land Bank Of The Philippines Account Name: Caraga Regional Hospital-trust Fund Account Number: 0982 -1288 – 70 12. Furthermore Deposit Slip Shall Be Submitted Via Email To: Crhprocurement.bac@gmail.com 13. The Procuring Entity Will No Longer Accept Nor Entertain Any Form Of Bids Submission Except Electronic. Failure To Comply Electronic Submission Will Be Immediately Disqualified. Guideline On The Electronic Submission Is Hereby Attached. 14. Join The Caraga Regional Hospital Supplier Network By Filling Out The Registry Form From This Link : Https://bit.ly/crh_suppliersregistry 15. For Further Information, Please Inquire To: Bac Secretariat Caraga Regional Hospital. Rizal Street, Surigao City Tel. Nos. (086) 826-1575 Local 194 Direct Line: (086) 826-9058 Mobile Nos. 09850508783 (smart/tnt) 09539212832 (globe/tm) E-mail Address: Crhprocurement.bac@gmail.com Approved By: (sgd) Fermarie C. Dulpina, Rmt, Mpa, Jd Chief Health Program Officer Chairman, Bids And Awards Committee
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Healthcare and Medicine
United States
Closing Soon10 Jan 2025
Tender AmountRefer Documents
Details: Sources Sought Notice sources Sought Notice *= Required Field
sources Sought Notice page 1 Of 4
page 1 Of 4 this Is A Sources Sought Notice Only. The Purpose Of This Sources Sought Notice Is To Obtain Information Regarding The Availability And Capability Of All Qualified Sources To Perform A Potential Requirement, And To Gain Knowledge Of Potential Qualified Service-disabled Veteran Owned Small Business (sdvosb), Veteran Owned Small Business (vosb), Small Business Manufacturers, And Other Small Businesses, Interested And Capable Of Providing Items Requested, As Well As Any Large Business Interested And Capable. This Request For Information/sources Sought Notice In Support Of The Portland Va Medical Centers, Is For Market Research Purposes And Planning Purposes Only And Is Not To Be Construed As A Commitment By The Government. The Government Will Not Pay For Information Solicited. Respondents Will Not Be Notified Of The Results Of The Evaluation. Results Will Be Used To Determine Set-aside. the Intended Contract Is A Firm-fixed Price Supply Purchase. the Sba Non-manufacturer Rule Is Applicable, And A Waiver Will Not Be Sought For This Potential Acquisition. potential Contractors Shall Provide, At A Minimum, The Following Information: 1) Company Name, Address, And Point Of Contact, Phone Number, E-mail Address, And Sam.gov Uei Number/code. 2) Anticipated North American Industry Classification System (naics) Code Is 339113. The Largest A Firm Can Be And Still Qualify As A Small Business For Federal Government Programs Is No More Than 800 Employees. Please Indicate Whether You Are A Small Business, Sdvosb, Vosb, Small Business Manufacturer, Other Small Business, Or Large Business, And Whether You Are The Manufacturer Of The Items Listed Below. 3) The Government Is Not Obligated To Nor Will It Pay For Or Reimburse Any Costs Associated With Responding To This Sources Sought Notice. This Notice Shall Not Be Construed As A Commitment By The Government To Issue A Solicitation Or Ultimately Award A Contract, Nor Does It Restrict The Government To A Particular Acquisition Approach. The Government Will In No Way Be Bound To This Information If Any Solicitation Is Issued. Notice To Potential Offerors: All Offerors Who Provide Goods Or Services To The United States Federal Government Must Be Registered In The System Award Management (sam Located On The Web At Www.sam.gov). It Is Desirable That Any Offeror To Have Completed Their Business Online Representations And Certifications Application In The System For Award Management (sam). 4) Any Service-disabled Veteran Owned Businesses Or Veteran Owned Businesses Who Respond To A Solicitation On This Project Must Be Registered With The Small Business Administration Vetcert Registry Located At Https://veterans.certify.sba.gov. 5) If Not A Manufacturer, Only Authorized Representatives/providers/distributors Of The Manufacturer Will Be Considered. Equipment Must Be New, No Used Or Refurbished Equipment Accepted. Please Provide A Proof Of Authorized Dealer Or Reseller Letter From Manufacturer. 6) If You Are The Manufacturer, Do You Have Any Designated Or Authorized Distributors? If So, Please Provide Their Name, Telephone, Point Of Contact And Size Status (if Available). 7) This Is A Brand Name Or Equal Requirement. As Such, The Salient Characteristics Reflect The Physical, Functional, Or Performance Characteristics That Equal Products Must Meet To Satisfy The Government S Needs. To Be Considered For Any Potential Solicitation, Offers Of Equal Products, Including Equal Products Of The Brand Name Manufacturer, Must: (a) Meet The Salient Physical, Functional, Or Performance Characteristic Of The Brand Name Item And Those Specified In This Sources Sought; Clearly Identify The Item By Brand Name, If Any And Make/model Number. (b) Include Descriptive Literature Such As Illustrations, Drawings, Or A Clear Reference To Descriptive Data Or Information Available That Identifies That The Equal Item Meets Or Exceeds The Salient Characteristics Required By The Government. (c) Identify The Manufacturer Name (oem) And Manufacturer Part Number, As Well As Any Warranty Information. (d) Please Provide A Courtesy Quote In Response To This Request To Evaluate Price Reasonableness For Any Set-aside Determination, And Any Applicable Contract Vehicle Information. it Is The Intent Of The Va To Use The Information Gathered For Market Research Purposes Only. If A Formal Solicitation Is Released, It Will Be Posted Via The Contracting Opportunities Website Located At Beta.sam.gov. Or Gsa Ebuy. description Of The Requirement: the Department Of Veterans Affairs Is Looking To Obtain Information On Vendors Who Can Provide The Products As Outlined Below. This Is An Unrestricted/open Market Brand Name Or Equal To Request For Information/sources Sought Notice. delivery: portland Va Medical Center
community Living Center
1601 E 4th Plain Blvd
vancouver, Wa 98661 items: Brand Name Or Equal To Hillrom Centrella item #
description/part Number*
qty Price Extended Amount 1
centrella Bed With Pro Surface
cnt 255
3 2
centrella Smart+ Bed With Max Air Surface And Blower
cnt 355
8 3
bed Base
cnt Base
11 4
nurse Call In Siderail
11 5
accessory Outlet
11 6
patient Helper Bracket
11 7
osi Patient Helper Sleeve
11 8
pro Surface For 36 Inch Frame
3 9
safeview With Illumiguide
3 10
second Lcd Touchscreen
3 â Subtotal (products)
â salient Characteristics max Air Feature Powered Air Mattress Operates Continuously To Decrease Localized Heat And Moisture Buildup. Allows For Continuous Full-body Pressure Redistribution For Patients 70 To 500 Pounds, Automatically Adjusts The Air System To Accommodate Changes Weight Distribution.
ability To Override And Increase Firmness For Patient Transfers Or Adjust Patient Position.
ability To Adjust For Patient Comfort, With 2 Zones, Which Can Be Adjusted Separately.
gci Touchscreen Located On The Outside Of The Head Rails For Quick Caregiver Access To Patient And Bed Status As Well As Other Bed Controls. Approximate Size 4x5 Inches
bed Exit Silence Exit Alarm Settings To Include Silence, Auto Reset, And Visual And Audible Safety Prompts. brake Not Set Alarm Spoken Verbal Safety Alert To Caution Caregiver And Patient In A Non-alarming Manner.
one Button Chair One Button Control To Convert A Flatbed Into A Cardiac Chair.
battery Backup - 12 Volt, 7 Mil Amp Hour Batteries X 2
digital Angle Indicator Digital Angle Indicator Gives The Specific Reading Of The Angle Of Bed If Trendelenburg Or Reverse Trendelenburg Positioning Is Needed. 18 Degrees Is The Maximum Achievable Angle.
built In Line And Cord Mgmt - Cutouts For Electrical Cord Or Monitor Cable Management For Use During Transporting. Located Within The Head And Footboards.
4 Iv Pole Sockets - Sized For Standard Hospital Iv Poles. 2-4 Bag Capacity.
integrated Restraint Holders - Sized For Standard Belt Restraints.
lockout Controls Ability To Lock Controls.
drainage Bag Holder Ability To Hold Up To 20 Pounds.
smart Bed Ready (sidecom Req) - Up To 32 Patients Safety And Bed Matrices To Be Transmitted To Caregiver Devices (such As Smart Phones, Vocera, Etc) And/or Vista Or Cerner Emr
wi-fi Module
enhanced 3-mode Bed Exit - Includes Silence, Auto Reset And Visual And Audible Safety Prompts.
motion Activated Nightlight
stand Assist - Height Adjust Buttons To Aid In Safely Lifting The Patient Onto Their Feet
advanced Slideguardâ® Feature - Reduces Patient Migration In Bed When The Head Of The Bed Is Raised
foley Position Limit - Monitors And Alerts If A Foley Bag Is Touching The Floor
patient Hob Angle Display - Digital Head Of Bed Angle Indicator Gives The Specific Reading Of The Angle Of The Head
trend/rev Trendelenburg Ranges From 0-18 Degrees.
dampened Emergency Cpr - Ability To Quickly And Safely Lower The Head Section To A Flat Position In Case Of A Code. Ability To Access From Both Sides Of The Bed.
patient Storage In Siderail - Sized To Hold Items Such As Smart Phone, Reading Glasses, Books/magazines. integrated Urinal Holders Ability To Hold Any Sized Urine Collection Bottle That Is Filled.
flexafoot Powered Bed Extend Powered Bed Length Extension.
steer Caster Font Left Caster Can Be Locked For Steering
36 Inch Frame Width
in-bed Scale Ability To Weight Up To 500 Pounds
usb Charger
2nd Lcd Touchscreen
patient Pendant - Moveable Bed Control That Allows The Patient Easy Access To Adjust The Bed S Head And Foot Sections. Approx. Size Is 3 X 5 .
removable Iv Pole
verbal Alerts Verbal Safety Alerts Such As Brake Not Set, Your Care Team Has Been Called, Please Don T Get Up, Etc. Able To Set 6 Different Languages.
additional Information Sought:
warranty Please Describe The Offered Warranty.
place Of Manufacture Please Provide The Place Of Manufacture. if Your Business Is Interested And Capable, Please Send The Capability Statement Outlined Above, And A Courtesy Market Research Quote To Maureen.sundstrom@va.gov By 3:00pm Pst On January 10, 2025. No Phone Calls, Please. again, This Is Not A Request For Quote, And No Solicitation Is Available At This Time.
DEPT OF THE NAVY USA Tender
Others
United States
Closing Soon13 Jan 2025
Tender AmountRefer Documents
Description: Commercial Product Procurement Notice|5||||||
item Unique Identification And Valuation (jan 2023)|19||||||||||||||||||||
inspection Of Supplies--fixed-price (aug 1996)|2|||
inspection And Acceptance - Short Version|8|x||x||||||
stop-work Order (aug 1989)|1||
general Information-fob-destination|1|b|
wide Area Workflow Payment Instructions (jan 2023)|16|invoice And Receiving Report (combo)|n/a|tbd|n00104|tbd|tbd|see Schedule|tbd|n/a|n/a|n/a||||||
federal Acquisition Supply Chain Security Act Orders-prohibition (dec 2023)|12|||||||||||||
contract Terms And Conditions Required To Implement Statutes Or Executiveorders--commercial Products And Commercial Services (nov 2024))|83||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
continued: Contract Terms And Conditions Required To Implement Statutes Or Executive Orders--commercial Products And Commercial Services (nov 2024))|15||||||||||||||||
annual Representations And Certifications (may 2024)|13|335910|1250||||||||||||
notice Of Priority Rating For National Defense, Emergency Perpardeness, And Enrgy Progam Use (april 2008))|2|||
evaluation--commercial Products And Commercial Services (nov 2021)|4|||||
a Material Irpod Is Available At The Bpmi Website.
please Specify (if Other Than 60 Days) ______________ Days.if You Are Submitting Your Quote Via Email Or Neco,please Specify The Number Of Days Pricing Is Valid.
all Contractual Documents (i.e. Contracts, Purchase Orders, Task Orders,delivery Orders And Modifications) Related To The Instant Procurement Areconsidered To Be 'issued' By The Government When Copies Are Either Depositedin The Mail, Transmitted By Facsimile, Or
sent By Other Electronic Commercemethods, Such As Email. The Government's Acceptance Of The Contractor's Proposal Constitutes Bilateral Agreement To 'issue' Contractual Documents As Detailed Herein.
1. Scope
1.1 In The Event Of A Conflict Between Section "c" And Section "d" Of The Contract/purchase Order, Section "c" Will Take Precedence.
2. Applicable Documents
2.1 Applicable Documents; There Are No Technical Documents; Such As, Drawings, Technical Data, Etc. Associated To This Solicitation/award, The Part Number/catalog Number Cited In The Requirements Section Is Fully Descriptive.
3. Requirements
3.1 Manufacture And Design- The Battery Furnished Under This Contract/purchase Order Shall Meet The Requirements As Specified In The Procurement Specification. The Requirements For This Contract/purchase Order Are As Follows:
1. Design, Material And Dimensions Are To Be In Accordance With
a. Manufacture: ;panasonic Corporation Of North America (61058); .
b. Drawings: ;.; .
piece: ;.; .
revision: ;.;
c. Part Number: ;fz-vzsu84au
alternate Part No: Fz-vzsu84a2u (61058); .
d. Catalog Number: ;.; . E. Marking Requirements - Marking And Labeling Shall Be In Accordance With Mil-std-129. In Addition To The Standard Marking Requirements Of Mil-std-129, The Seller Shall Include The Manufacturer's Federal Supply Code For Manufacturers (fscm/cage Code) And The
item's Part Number On Intermediate And Unit Packs. Special Marking Which Includes Both Type I And Type Ii Shelf Life Items, Cure Date And Expiration Date In Accordance With Mil-std-129 Also Apply.
items Shall Be Supplied With At Least 85% Of The Shelf Life Remaining At The Time Of Shipment. Shelf-life Is ;24; Months.
f. Additional Ordering Data: ;.; .
3.2 Navsup Wss-mech Code N94 Additional Technical Documentation
order Of Precedence And Effective Issues Of Cited Documentation Dated: July 2004
a. Order Of Precedence For Document Conflict Resolution: The Technical And Quality Requirements Applicable To Manufacture Of The Material Being Purchased Under This Order Are Contained Or Invoked In One Or More Of The Documents Listed Below. In The Event Of
any Inconsistencies Between Any Provisions Of This Order, The Order Or Precedence Shall Be As Follows:
1. Amendments To The Purchase Order/contract
2. Schedule Of Supplies Of The Purchase Order/contract.
3. Terms And Conditions Of The Purchase Order/contract.
4. Individual Repair Part Ordering Data (irpod); Or Master Procurement Specification, As Applicable.
5. Any Invoked Standard Technical Requirements (strs).
6. Drawings Referenced In The Irpod, Or Master Procurement Specification , As Applicable.
7. Specifications Referenced In The Irpod, Master Procurement Specifications Or Drawing(s), As Applicable.
b. Effective Issues Of Cited Drawings, Specifications, Standards And Other Documents: 1. The Contractor Shall Comply With The Specified Revisions Of The Documents (i.e. Drawings,specifications,standards And Other Documents) Cited In The Irpod And/or Procurement Specification Contained Herein. The Contractor Shall Obtain Written Approval
for The Contracting Officer To Use Document Revisions Other Than Those Specified. When A Later Drawing Revision Is Submitted For Approval, Two Full Size Clear Legible Prints Shall Be Provided. 2. Where Documents Are Referred To Only By The Basic Identification Name Or Number And No Specific Revision Thereto, The Contractor Use Of Any Issue Of The Document Except All Such Revisions Shall Be Dated 1 November 1969 Or Later.
c. Use Of Document Revisions In Their Entirety:
1. Contractors Shall Use Revisions To Each Cited Or Referenced Document In Its Entirety Unless The Contractor Obtains Contracting Officer Approval To Do Otherwise (i.e. The Contractor Shall Not Use Portions Of Different Revisions Of A Document).
d. Vendor Waiver/deviations On Critical Contracts.
1. Compliance With The Delivery Date And Technical Requirements Of Navsup Wss Critical Repair Part Material Contracts Is Expected.
2. As The Cautionary Note Contained In The Contract States, Seller Intended Use Of Any Material Which Is Not In Full Compliance With The Specified Contract Technical Requirements, Should Be Identified As An Exception In Advance Either At The Time The Quotation
is Submitted Or Prior To Manufacture.
3. Requests For Delivery Date Extensions And Waivers/deviations Should Be Accompanied By An Explanation Of The Cause For The Delay, Or The Reason For The Requested Non-conformance With An Offer Of Consideration In The Event The Contracting Officer Concurs With
your Request.
4. Requests For Waivers/deviations Should Provide Justification For The Requested Change Including An Evaluation Which Demonstrates That Proposed Non-conformance Will Not Affect The Quality, Form, Fit, Or Function Of The Part. Where A Proposed Alternate Or
replacement Item Is Offered, Supporting Technical Data (catalog Page, Drawing (s), Etc.) That Fully Describe The Proposed Item Shall Be Provided For Technical Evaluation.
5. Requests Which Do Not Contain The Above Information Will Be Returned And Will Not Be Submitted To Technical/engineering Review Until Sufficient Justification Is Provided.
6. Requests For Waivers/deviations Shall Be Presented To The Government Quality Assurance Representative (qar) For Comment. The Qar Shall Forward The Request, With Their Comments, Directly To The Post Award Pco Identified In The Contract/purchase Order Within
five Working Days After Receipt.
e. Exclusion Of Mercury
1. Mercury Or Mercury Containing Compounds Shall Not Be Intentionally Added To Or Come In Direct Contact With Hardware Or Supplies Under This Contract.
4. Quality Assurance
4.1 Quality Assurance Requirements- The Contractor Shall Provide And Maintain An Inspection System Acceptable To The Government Covering The Supplies Herein.
records Of All Inspection Work By The Contractor Shall Be Kept Complete And Available To The Government During The Performance Of This Contract And For Such Longer Periods As May Be Specified Elsewhere In The Contract.
5. Packaging
5.1 When The Cleanliness Control Requirements Of One Or More Of The Following Documents Are Invoked: Mil-std-767, Mil-std-2041, Refueling Clean, Or Reactor Plant Clean, The Following Clarification Of Requirements For Mil-prf-23199 Packaging Of Repair Parts
applies.
(1). The Following Summary Clarifies The Packaging Requirements Of Mil-prf-23199 Pertaining To The Use Of Mil-dtl-24466 Green Poly Bags. The Supplier Remains Responsible For Meeting All Contract Requirements. Suppliers Who Are Unsure Of The Packaging, Packing,
and Marking.
requirements For A Particular Part Should Request Clarification By Contacting The Navsup-wss Contracting Poc.
(a). Paragraph 3.4.2 Of Mil-prf-23199 Discusses Level B Packaging And Refers To Paragraph 3.3.1 For The Method Of Packaging. Paragraph 3.3.1 Provides Several Methods Of Packaging. Packaging In Heat Sealed Envelopes Is Covered In Paragraph 3.3.1.1 Which States,
"components Which Are Subject To Cleanliness Controls (see 6.2) Or As Specified (see 6.1) Shall Be Packaged In Heat Sealed Envelopes (see 3.2.2.5 And 3.2.2.5.1)".
(2). The Following Conditions Must Be Satisfied In Order For Mil-dtl-24466 Bags To Apply:
(a). Paragraph 6.2 Of Mil-prf-23199 Defines Cleanliness Controls As Any Reference To (or Application Of) The Cleanliness Control Requirements Of One Or More Of The Following Documents: Mil-std-767, Mil-std-2041, Refueling Clean, Reactor Plant Clean, Or Other
requirements Identified Within The Irpod.
the Repair Part Must Have Cleaning Requirements Of One Of The Aformentioned Methods.
(b). Paragraph 6.1 Contains Ordering Data Options. Paragraph 6.1(k)2. Provides An Option To Specify The Method Of Packaging To Be Used When Packaging Is Other Than In Accordance With Paragraph 3.3.1.1 Only. If A Contract Specifies Any Additional Requirements
for The Use Of Green Poly Bags, Then They Are Required And Take Precedence.
(4). The Use Of Fire Retardant Packaging Material Is No Longer Required In Any Navsup-wss N94 Contract.
mil-std 2073 Packaging Applies As Found Elsewhere In The Schedule
6. Notes
6.1 1. Nuclear Reactor Publications Assigned Navsea Document And Identification Numbers That Are Not Available From Bpmi E-commerce Web Site Must Be Requested From:
contracting Officer
navsup Wss-mech
code N943
5450 Carlisle Pike
p.o. Box 2020
mechanicsburg, Pa. 17055-0788
requests For "official Use Only" And "noforn" (not Releasable To Foreign Natio Nals) Documents Must Identify The Quotation Number On Pre-award Procurement Actions. Requests Must Be Submitted To The Pco For Certification Of "need-to-know" For The Document. On
post-award Actions, The Request Must Identify The Government Contract Number, And Be Submitted Via The Defense Contract Management Agency (dcma) For Certification Of "need-to-know" For The Document.
2. Commercial Specifications, Standards And Descriptions - These Specifications, Standards And Descriptions Are Not Available From Government Sources. They May Be Obtained From The Publishers Or Societies Of The Applicable Documents.
6.2 In Accordance With Dodi 5230.24 All Documents And Drawings Provided By The U.s. Navy To Prospective Contractors Must Include A "distribution Statement" To Inform The Contractor Of The Limits Of Distribution, And The Safeguarding Of The Information
contained On Those Documents And Drawings. There Are 6 (six) Separate Distribution Statement Codes Used For Non-classified Documents And Drawings. The Definition For Each Is As Follows:
a... Approved For Public Release; Distribution Is Unlimited.
b... Distribution Authorized To Us Governments Agencies Only.
c... Distribution Authorized To Us Government Agencies And Their Contractors.
d... Distribution Authorized To Dod And Dod Contractors Only.
e... Distribution Authorized To Dod Components Only.
f... Further Distribution Only As Directed By Commander, Naval Sea Systems Command, Code 09t.
Department Of Agrarian Reform Tender
Automobiles and Auto Parts
Philippines
Closing Date20 Jan 2025
Tender AmountPHP 300 K (USD 5.1 K)
Details: Description Invitation To Bid Itb#: 2024-021 Supply And Delivery Of One (1) Unit Three-wheel Motorcycle Cargo With Canopy Under Pahp Program For Fy 2025 1. The Department Of Agrarian Reform, Provincial Office, Nabunturan, Davao De Oro Thru The General Appropriations Act For Fy 2025 Intends To Apply The Sum Of Three Hundred Thousand Pesos (php 300, 000.00) Being The Approved Budget For The Contract (abc) To Payment Under The Contract For The Supply And Delivery Of One (1) Unit Three-wheel Motorcycle Cargo With Canopy Under Pahp Program For Fy 2025. Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. 2. The Dar Provincial Office Now Calls For The Submission Of Eligibility Documents For The Supply And Delivery Of One (1) Unit Three-wheel Motorcycle Cargo With Canopy Under Pahp Program For Fy 2025: No Particulars Approved Budget Of Contract Amount Of Bidding Doc 1. One (1) Unit Of Three-wheel Motorcycle Cargo With Canopy 300,000.00 500.00 Specifications: Weight: Vehicle Kerb Weight: 503 Kg; Gross Vehicle Weight: 990 Kg; Performance: Max. Speed: 60 Kmph; Min. Turning Radius: 3240 Mm Engine: Four Stroke, Spark Ignition Engine; Bore X Stroke (mm): 67×67; Engine Displacement (cc): 236.2; Idling Speed: 1400 ± 300; Max. Net Power: 8.00 Kw @ 4500 ± 250 As Per Is:14599; Max. Net Torque: 20.1 N-m @ 3500 ± 250 As Per Is:14599 Ignition System: Spark Plug: Bosch Ur6cc, Champion Rg6hcc; Transmission: 4 Forward + 1 Reverse; Electrical: System: 12v Dc; Head Lamp: 35/35 W; Stop Lamp/tail Lamp: 21/ 5 W; Turn Signal Lamp: 10 W; Neutral Indicator Lamp: Available (2w); Speedometer Lamp: Available (2w); Horn: 12v Dc, Type 2a; Battery: 12v, 32 Ah Fuel Tank Capacity: Full 12l Tire: Front Pressure: 34 Psi (2.4 Kg/cm2); Rear Pressure: 58 Psi (4.0 Kg/cm2); Front Tire Size: 4.5x10″; Rear Tire Size: 4.5x10″; Brake: Front /rear Drum / Drum (200) -other Requirements: •complete Basic Tools And Accessories •with Reflectorized Dar Davao De Oro Logo And Bagong Pilipinas Logo •delivered On-site: Lifico, Montevista, Davao De Oro 3. Bidders Should Have Completed Similar Contracts Within The Past Three (3) Years Prior To The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of Eligible Is Contained In The Bidding Documents, Particularly, In Section Ii. 4. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The Implementing Rules And Regulations (irr) Of Republic Act (ra) 9184, Otherwise Known As The “government Procurement Reform Act”. Bidding Is Restricted To Filipino Citizens, Sole Proprietorship, Partnership, Organization With At Least Sixty Percent (60%), Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, Or To Citizens Or Organizations Of A Country Wherein The Laws And Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To R.a. 5183 And Subject To Commonwealth Act No. 138. 5. Interested Bidders May Obtain Further Information From The Dar-bac Secretariat And Inspect The Bidding Documents At The Address Given Below During Workdays From 10:00 Am To 5:00 Pm. The Complete Set Of Bidding Documents May Be Purchased By Interested Bidders At The Same Address And Upon Payment Of A Non-refundable Amount Of Php 500.00. 6. It May Also Be Downloaded From The Website Of The Philippines Government Procurement System (http://www.philgeps.net/), Provided That Bidders Shall Pay The Non-refundable Fee For The Bidding Documents Not Later Than The Submission Of Their Bids. However, Only Those Who Participate In The Face-to-face Pre-bid Conference Shall Be Allowed To Purchase The Bidding Documents And Participate The Bidding. 7. The Dar-pbac Will Hold A Pre-bid Conference On January 6, 2025, 10:00 Am At Darpo Davao De Oro, Conference Room, Purok 18, Palmera Village, Poblacion, Nabunturan, Davao De Oro. 8. Bids Must Be Delivered To The Address Below On Or Before 12:00 Nn On January 20, 2025. All Bids Must Be Accompanied By Bid Security In Any Of The Acceptable Forms And In The Amount Of Itb Clause 18. Late Bids Shall Not Be Accepted. 9. Bid Opening Shall Be On January 20, 2025 At 1:00pm At Darpo Davao De Oro, Conference Room, Purok 18, Palmera Village, Poblacion, Nabunturan, Davao De Oro. Bids Will Be Opened In The Presence Of The Bidders Representatives Who Choose To Attend At The Address Below. 10. The Department Of Agrarian Reform Provincial Office Reserves The Right To Accept Or Reject Any Bid, To Annul The Bidding Process, And To Reject All Bids At Any Time Prior To Contract Award, Without Thereby Incurring Any Liability To The Affected Bidders. 11. For Further Information, Please Refer To: Ma. Michelle T. Epal, Mpa Bac Secretariat Head Dar Provincial Office, Purok 18, Palmera Village, Poblacion, Nabunturan, Davao De Oro, Philippines 09566334508 Darpocomvalprocurement@gmail.com (sgd.)nancy S. Ramos, Mpa Bac Chairperson
Bureau Of Corrections leyte Regional Prison Abuyog Leyte Tender
Healthcare and Medicine
Philippines
Closing Soon13 Jan 2025
Tender AmountPHP 596.4 K (USD 10.2 K)
Details: Description Bids & Awards Committee Invitation For Negotiated Procurement - Two-failed Biddings For The Request For Supply & Delivery Of Medical Supplies 2025 1. The Leyte Regional Prison (lrp) Intends To Procure Medical Supplies 2025 With An Approved Budget For The Contract (abc) Amounting To Five Hundred Ninety-six Thousand Four Hundred Seventy-seven Pesos Only (php 596,477.00). 2. The Lrp Bids And Award Committee (bac) Now Invites Technically, Legally, And Financially Capable Suppliers For The Said Project. 3. The Procurement Procedure For This Requirement Is Negotiated Procurement For Two-failed Bidding Pursuant To Section 53.1 Of 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. The Selection Of The Successful Offer Shall Be Based On The Best And Final Offer That Will Be Submitted On The Set Deadline By The Bac And Which Would Meet The Minimum Technical Specifications Required. 4. The Interested Bidders May Obtain Further Information From The Bac Secretariat At The Address Given Below From 09 January 2025 To 13 January 2025 Before 9:00am. 5. The Lrp Will Hold A Negotiation Meeting On 13 January 2025 At Exactly 9:00am At Conference Room, Admin Building, Lrp, Abuyog, Leyte, Which Shall Be Open To Prospective Bidders. 6. Four (4) Copies Of The Proposals (one Original And Three Copies) Must Be Submitted To The Bac Which Must Be Duly Received By The Bac Secretariat Through Manual Submission At The Office Address Indicated Above On Or Before 5:00 Pm Of 14 January 2025. Late Submission Shall Not Be Accepted. 7. Interested Bidders Shall Submit The Following Documents In Sealed Envelopes, Labeled As “negotiated Procurement For Two-failed Biddings”, With The Title Of The Procurement Project, Name Of The Bidder, Address, And The Contact Details Of The Bidder, Addressed To The Bac. I. Technical Component Envelope Class “a” Documents Legal Documents (a) Valid Philgeps Registration Certificate (platinum Membership) (all Pages) In Accordance With Section 8.5.2 Of The Irr; Technical Documents (b) Statement Of The Prospective Bidder Of All Its Ongoing Government And Private Contracts, Including Contracts Awarded But Not Yet Started, If Any, Whether Similar Or Not Similar In Nature And Complexity To The Contract To Be Bid; And (c) Statement Of The Bidder’s Single Largest Completed Contract (slcc) Similar To The Contract To Be Bid, Except Under Conditions Provided For In Sections 23.4.1.3 And 23.4.2.4 Of The 2016 Revised Irr Of Ra No. 9184, Within The Relevant Period As Provided In The Bidding Documents; And (d) Original Copy Of Bid Security. If In The Form Of A Surety Bond, Submit Also A Certification Issued By The Insurance Commission Or Original Copy Of Notarized Bid Securing Declaration; And (e) Conformity With The Schedule Of Requirements (annex “a”) & Technical Specifications (annex “b”), Which May Include Production/delivery Schedule, Manpower Requirements, And/or After-sales/parts, If Applicable; And (f) Original Duly Signed Omnibus Sworn Statement (oss) And If Applicable, Original Notarized Secretary’s Certificate In Case Of A Corporation, Partnership, Or Cooperative; Or Original Special Power Of Attorney Of All Members Of The Joint Venture Giving Full Power And Authority To Its Officer To Sign The Oss And Do Acts To Represent The Bidder. Financial Documents ⬜ (g) The Prospective Bidder’s Computation Of Net Financial Contracting Capacity (nfcc) Or A Committed Line Of Credit From A Universal Or Commercial Bank In Lieu Of Its Nfcc Computation. Class “b” Documents ⬜ (h) If Applicable, A Duly Signed Joint Venture Agreement (jva) In Case The Joint Venture Is Already In Existence Or Duly Notarized Statements From All The Potential Joint Venture Partners Stating That They Will Enter Into And Abide By The Provisions Of The Jva In The Instance That The Bid Is Successful. Ii. Financial Component Envelope ⬜ (i) Original Of Duly Signed And Accomplished Financial Bid Form; And ⬜ (j) Original Of Duly Signed And Accomplished Price Schedule(s). 8. The Special Conditions Of The Contract (annex “c”) Shall Form Part Of The Contract. Other Conditions Of The Contract Shall Be Governed By The Implementation Of The Rules And Regulations Of Ra 9184 And Other Related And Applicable Laws. Issued This 8th Day Of January 2025. Mr. Tracy B. Soriano, Msca Chairperson, Bids And Awards Committee Company Letterhead Statement Of Ongoing Government & Private Contracts Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 Statement Of All Its Ongoing Government And Or Private Contracts Including Contracts Awarded But Not Yet Started, If Any Whether Similar Or Not Similar In Nature. Name Of Contract Date Of Contract Contract Duration Owner’s Name And Address Kind Of Goods Amount Of Contract Value Of Outstanding Contract Total Value Of Outstanding Contract: Certified Correct: Name And Signature Of Authorized Representative Position Date Company Letterhead Statement Of Single Largest Completed Contract Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 Statement Of Single (1) Largest Completed Contract Of Similar In Nature Within The Last Two (2) Years From The Date Of Submission And Receipt Of Bids Amounting To At Least Twenty-five Percent (25%) Of The Approved Budget Of The Contract (abc) Name Of Contract Date Of Contract Contract Duration Owner’s Name And Address Kind Of Goods Amount Of Contract Amount Of Completed Contracts, Adjusted By The Bidder To Current Prices Using Psa’s Consumer Price Index, If Necessary Date Of Delivery End User’s Acceptance Or Official Receipt(s) Or Sales Invoice Issued For The Contract, (attached Copy) Certified Correct: Name And Signature Of Authorized Representative Position Date Company Letterhead Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 Republic Of The Philippines) City Of _______________________) S.s. X------------------------------------------------------x Bid Securing Declaration Invitation To Bid: [insert Reference Number] To: Leyte Regional Prison I/we, The Undersigned, Declare That: 1. I/we Understand That, According To Your Conditions, Bids Must Be Supported By A Bid Security, Which May Be In The Form Of A Bid-securing Declaration. 2. I/we Accept That: (a) I/we Will Be Automatically Disqualified From Bidding For Any Contract With Any Procuring Entity For A Period Of Two (2) Years Upon Receipt Of Your Blacklisting Order; And, (b) I/we Will Pay The Applicable Fine Provided Under Section 6 Of The Guidelines On The Use Of Bid Securing Declaration, Within Fifteen (15) Days From Receipt Of The Written Demand By The Procuring Entity For The Commission Of Acts Resulting To The Enforcement Of The Bid Securing Declaration Under Sections 23.1(b), 34.2, 40.1 And 69.1, Except 69.1(f), Of The Irr Of Ra 9184; Without Prejudice To Other Legal Action The Government May Undertake. 3. I/we Understand That This Bid Securing Declaration Shall Cease To Be Valid On The Following Circumstances: (a) Upon Expiration Of The Bid Validity Period, Or Any Extension Thereof Pursuant To Your Request; (b) I Am/we Are Declared Ineligible Or Post-disqualified Upon Receipt Of Your Notice To Such Effect, And (i) I/we Failed To Timely File A Request For Reconsideration Or (ii) I/we Filed A Waiver To Avail Of Said Right; (c) I Am/we Are Declared The Bidder With The Lowest Calculated Responsive Bid, And I/we Have Furnished The Performance Security And Signed The Contract. In Witness Whereof, I/we Have Hereunto Set My/our Hand/s This ____ Day Of [month] [year] At [place Of Execution]. [insert Name Of Bidder’s Authorized Representative] [insert Signatory’s Legal Capacity] Affiant Subscribed And Sworn To Before Me This ___ Day Of [month] [year] At [place Of Execution], Philippines. Affiant/s Is/are Personally Known To Me And Was/were Identified By Me Through Competent Evidence Of Identity As Defined In The 2004 Rules On Notarial Practice (a.m. No. 02-8-13-sc). Affiant/s Exhibited To Me His/her [insert Type Of Government Identification Card Used], With His/her Photograph And Signature Appearing Thereon, With No. ________ And His/her Community Tax Certificate No. _______ Issued On ____ At ______. Witness My Hand And Seal This ___ Day Of [month] [year]. Name Of Notary Public Serial No. Of Commission _______________ Notary Public For _______ Until __________ Roll Of Attorneys No. __________________ Ptr No. ______ [date Issued], [place Issued] Ibp No. ______ [date Issued], [place Issued] Doc. No. _____ Page No. _____ Book No. _____ Series Of _____ Section Vi. Schedule Of Requirements Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 The Delivery Schedule Expressed As Weeks/months Stipulates Hereafter A Delivery Date Which Is The Date Of Delivery To The Project Site. # Description Qty Dosage Form Delivered, Weeks/months 1 Acid Fast Stain, Medic (ziel-neelsen Hot Method) 3 Pcs Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 2 Acepto Bulb Syringe 5 Pcs Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 3 Adult Pulse Oximeter Fingertip (durable) 5 Pcs Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 4 Alcohol 70% Gallon 100 Gallon Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 5 Aneroid Sphygmomanometer W/ Stethoscope (durable) 10 Set Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 6 Battery Double Aa (heavy Duty) 50 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 7 Battery Triple Aaa (heavy Duty) 50 Capsule Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 8 Blood Collection Tube 5ml (lavender) 1 Box Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 9 Blood Collection Tube 5ml (yellow) 1 Box Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 10 Cold Compress Bag 5 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 11 Denatured Alcohol 1l 2 Gallon Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 12 Disinfectant Solution 10 Litrs Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 13 Drug Testing Kit (urine) 1000 Unit Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 14 Dsn 10cc 500 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. I/we Hereby Commit To Comply And Deliver All The Requirement In Accordance With The Above Stated Schedule. Conforme: Name Of Company In Print Signature Printed Name Of Authorized Representative Date Section Vi. Schedule Of Requirements Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 The Delivery Schedule Expressed As Weeks/months Stipulates Hereafter A Delivery Date Which Is The Date Of Delivery To The Project Site. # Description Qty Dosage Form Delivered, Weeks/months 15 Dsn 3cc 700 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 16 Dsn 5cc 700 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 17 Dsn 1cc 500 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 18 Easy Touch Blood Glucose Strips 25's 20 Bottle Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 19 Easy Touch Blood Cholesterol Strips 25's 30 Bottle Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 20 Easy Touch Blood Uric Strips 25's 30 Bottle Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 21 Examination Disposable Latex Gloves Powder Free 100 Box Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 22 Face Mask 50's 100 Box Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 23 Heplock 20 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 24 Hot Water Bag 10 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 25 Hydrogen Peroxide 10 Volume 20 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 26 Iv Infusion Set Adult 500 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 27 Kidney Basin Stainless 4 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 28 Lubricating Jelly 80gms 50 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. I/we Hereby Commit To Comply And Deliver All The Requirement In Accordance With The Above Stated Schedule. Conforme: Name Of Company In Print Signature Printed Name Of Authorized Representative Date Section Vi. Schedule Of Requirements Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 The Delivery Schedule Expressed As Weeks/months Stipulates Hereafter A Delivery Date Which Is The Date Of Delivery To The Project Site. # Description Qty Dosage Form Delivered, Weeks/months 29 Medical Penlight 5 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 30 Medical Oxygen Regulator 5 Pcs Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 31 Muriatic Acid Solution 50 Gallon Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 32 Na Hypochlorite Solution 30 Gallon Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 33 Nebulizer 2 Set Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 34 One Touch Select Simple Test Strip 25's 50 Bottle Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed 35 Oxygen Mask Cannula 150 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed 36 Oxygen Trolley (5-20 Lbs) 2 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed 37 Petroleum Jelly 25gms 100 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed 38 Plastic Canister 3 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed 39 Plastic Splint Adult 10 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed 40 Rotahaler 50 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed 41 Sphygmomanometer Valve With Bulb 20 Set Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed 42 Sterile Latex Surgical Gloves #7, 50pairs/box 5 Box Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed I/we Hereby Commit To Comply And Deliver All The Requirement In Accordance With The Above Stated Schedule. Conforme: Name Of Company In Print Signature Printed Name Of Authorized Representative Date Section Vi. Schedule Of Requirements Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 The Delivery Schedule Expressed As Weeks/months Stipulates Hereafter A Delivery Date Which Is The Date Of Delivery To The Project Site. # Description Qty Dosage Form Delivered, Weeks/months 43 Soluset Infusion Set 5 Pcs Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 44 Urinal (male) 10 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. 45 Urine Container 50ml 1000 Pieces Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. I/we Hereby Commit To Comply And Deliver All The Requirement In Accordance With The Above Stated Schedule. Conforme: Name Of Company In Print Signature Printed Name Of Authorized Representative Date Section Vii. Technical Specifications Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 Item No. Qty. Dosage Form Agency Specification Bidder’s Statement Of Compliance 1 3 Pcs Acid Fast Stain, Medic (ziel-neelsen Hot Method) 2 5 Pcs Acepto Bulb Syringe 3 5 Pcs Adult Pulse Oximeter Fingertip (durable) 4 100 Gallon Alcohol 70% Gallon 5 10 Set Aneroid Sphygmomanometer W/ Stethoscope (durable) 6 50 Pieces Battery Double Aa (heavy Duty) 7 50 Capsule Battery Triple Aaa (heavy Duty) 8 1 Box Blood Collection Tube 5ml (lavender) 9 1 Box Blood Collection Tube 5ml (yellow) 10 5 Pieces Cold Compress Bag 11 2 Gallon Denatured Alcohol 1l 12 10 Litrs Disinfectant Solution 13 1000 Unit Drug Testing Kit (urine) 14 500 Pieces Dsn 10cc 15 700 Pieces Dsn 3cc 16 700 Pieces Dsn 5cc 17 500 Pieces Dsn 1cc I Hereby Certify That The Statement Of Compliance To The Foregoing Technical Specifications Are True And Correct, Otherwise, If Found To Be False Either During Bid Evaluation Or Post- Qualification, The Same Shall Give Rise To Automatic Disqualification Of Our Bid. ___________________________________________ Name Of Company In Print ___________________________________________ Signature Over Printed Name Of Authorized Representative Section Vii. Technical Specifications Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 Item No. Qty. Dosage Form Agency Specification Bidder’s Statement Of Compliance 18 20 Bottle Easy Touch Blood Glucose Strips 25's 19 30 Bottle Easy Touch Blood Cholesterol Strips 25's 20 30 Bottle Easy Touch Blood Uric Strips 25's 21 100 Box Examination Disposable Latex Gloves Powder Free 22 100 Box Face Mask 50's 23 20 Pieces Heplock 24 10 Pieces Hot Water Bag 25 20 Pieces Hydrogen Peroxide 10 Volume 26 500 Pieces Iv Infusion Set Adult 27 4 Pieces Kidney Basin Stainless 28 50 Pieces Lubricating Jelly 80gms 29 5 Pieces Medical Penlight 30 5 Pcs Medical Oxygen Regulator 31 50 Gallon Muriatic Acid Solution 32 30 Gallon Na Hypochlorite Solution 33 2 Set Nebulizer 34 50 Bottle One Touch Select Simple Test Strip 25's I Hereby Certify That The Statement Of Compliance To The Foregoing Technical Specifications Are True And Correct, Otherwise, If Found To Be False Either During Bid Evaluation Or Post- Qualification, The Same Shall Give Rise To Automatic Disqualification Of Our Bid. ___________________________________________ Name Of Company In Print ___________________________________________ Signature Over Printed Name Of Authorized Representative Section Vii. Technical Specifications Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 Item No. Qty. Dosage Form Agency Specification Bidder’s Statement Of Compliance 35 150 Pieces Oxygen Mask Cannula 36 2 Pieces Oxygen Trolley (5-20 Lbs) 37 100 Pieces Petroleum Jelly 25gms 38 3 Pieces Plastic Canister 39 10 Pieces Plastic Splint Adult 40 50 Pieces Rotahaler 41 20 Set Sphygmomanometer Valve With Bulb 42 5 Box Sterile Latex Surgical Gloves #7, 50pairs/box 43 5 Pcs Soluset Infusion Set 44 10 Pieces Urinal (male) 45 1000 Pieces Urine Container 50ml I Hereby Certify That The Statement Of Compliance To The Foregoing Technical Specifications Are True And Correct, Otherwise, If Found To Be False Either During Bid Evaluation Or Post- Qualification, The Same Shall Give Rise To Automatic Disqualification Of Our Bid. ___________________________________________ Name Of Company In Print ___________________________________________ Signature Over Printed Name Of Authorized Representative Company Letterhead Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 Omnibus Sworn Statement Republic Of The Philippines ) City/municipality Of ______ ) S.s. Affidavit I, [name Of Affiant], Of Legal Age, [civil Status], [nationality], And Residing At [address Of Affiant], After Having Been Duly Sworn In Accordance With Law, Do Hereby Depose And State That: 1. Select One, Delete The Other: If A Sole Proprietorship: I Am The Sole Proprietor Or Authorized Representative Of [name Of Bidder] With Office Address At [address Of Bidder]; If A Partnership, Corporation, Cooperative, Or Joint Venture: I Am The Duly Authorized And Designated Representative Of [name Of Bidder] With Office Address At [address Of Bidder]; 2. Select One, Delete The Other: If A Sole Proprietorship: As The Owner And Sole Proprietor, Or Authorized Representative Of [name Of Bidder], I Have Full Power And Authority To Do, Execute And Perform Any And All Acts Necessary To Participate, Submit The Bid, And To Sign And Execute The Ensuing Contract For Supply & Delivery Of Medical Supplies 2025 Of The Leyte Regional Prison As Shown In The Attached Duly Notarized Special Power Of Attorney; If A Partnership, Corporation, Cooperative, Or Joint Venture: I Am Granted Full Power And Authority To Do, Execute And Perform Any And All Acts Necessary To Participate, Submit The Bid, And To Sign And Execute The Ensuing Contract For The Supply & Delivery Of Medical Supplies 2025 Of The Leyte Regional Prison, As Shown In The Attached [state Title Of Attached Document Showing Proof Of Authorization (e.g., Duly Notarized Secretary’s Certificate, Board/partnership Resolution, Or Special Power Of Attorney, Whichever Is Applicable;)]; 3. [name Of Bidder] Is Not “blacklisted” Or Barred From Bidding By The Government Of The Philippines Or Any Of Its Agencies, Offices, Corporations, Or Local Government Units, Foreign Government/foreign Or International Financing Institution Whose Blacklisting Rules Have Been Recognized By The Government Procurement Policy Board; 4. Each Of The Documents Submitted In Satisfaction Of The Bidding Requirements Is An Authentic Copy Of The Original, Complete, And All Statements And Information Provided Therein Are True And Correct; 5. [name Of Bidder] Is Authorizing The Head Of The Procuring Entity Or Its Duly Authorized Representative(s) To Verify All The Documents Submitted; 6. Select One, Delete The Rest: If A Sole Proprietorship: The Owner Or Sole Proprietor Is Not Related To The Head Of The Procuring Entity, Members Of The Bids And Awards Committee (bac), The Technical Working Group, And The Bac Secretariat, The Head Of The Project Management Office Or The End-user Unit, And The Project Consultants By Consanguinity Or Affinity Up To The Third Civil Degree; If A Partnership Or Cooperative: None Of The Officers And Members Of [name Of Bidder] Is Related To The Head Of The Procuring Entity, Members Of The Bids And Awards Committee (bac), The Technical Working Group, And The Bac Secretariat, The Head Of The Project Management Office Or The End-user Unit, And The Project Consultants By Consanguinity Or Affinity Up To The Third Civil Degree; If A Corporation Or Joint Venture: None Of The Officers, Directors, And Controlling Stockholders Of [name Of Bidder] Is Related To The Head Of The Procuring Entity, Members Of The Bids And Awards Committee (bac), The Technical Working Group, And The Bac Secretariat, The Head Of The Project Management Office Or The End-user Unit, And The Project Consultants By Consanguinity Or Affinity Up To The Third Civil Degree; 7. [name Of Bidder] Complies With Existing Labor Laws And Standards; And 8. [name Of Bidder] Is Aware Of And Has Undertaken The Following Responsibilities As A Bidder: A) Carefully Examine All Of The Bidding Documents; B) Acknowledge All Conditions, Local Or Otherwise, Affecting The Implementation Of The Contract; C) Made An Estimate Of The Facilities Available And Needed For The Contract To Be Bid, If Any; And D) Inquire Or Secure Supplemental/bid Bulletin(s) Issued For The Supply & Delivery Of Medical Supplies 2025. 9. [name Of Bidder] Did Not Give Or Pay Directly Or Indirectly, Any Commission, Amount, Fee, Or Any Form Of Consideration, Pecuniary Or Otherwise, To Any Person Or Official, Personnel Or Representative Of The Government In Relation To Any Procurement Project Or Activity. In Witness Whereof, I Have Hereunto Set My Hand This __ Day Of ___, 20__ At ____________, Philippines. _____________________________________ Bidder’s Representative/authorized Signatory Subscribed And Sworn To Before Me This ___ Day Of [month] [year] At [place Of Execution], Philippines. Affiant/s Is/are Personally Known To Me And Was/were Identified By Me Through Competent Evidence Of Identity As Defined In The 2004 Rules On Notarial Practice (a.m. No. 02-8-13-sc). Affiant/s Exhibited To Me His/her [insert Type Of Government Identification Card Used], With His/her Photograph And Signature Appearing Thereon, With No. ________ And His/her Community Tax Certificate No. _______ Issued On ____ At ______. Witness My Hand And Seal This ___ Day Of [month] [year]. Name Of Notary Public Serial No. Of Commission _______________ Notary Public For _______ Until __________ Roll Of Attorneys No. __________________ Ptr No. ______ [date Issued], [place Issued] Ibp No. ______ [date Issued], [place Issued] Doc. No. _____ Page No. _____ Book No. _____ Series Of _____ Company Letterhead Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 Certificate Of Net Financial Contracting Capacity (please Show Figures At How You Arrived At The Nfcc) This Is To Certify That Our Net Financial Contracting Capacity (nfcc) Is _________________________(p____________) Which Is At Least Equal To The Total Ceiling Price We Are Bidding. The Amount Is Computed As Follows: (please Show Computation Of Nfcc) Nfcc = (ca-cl) (15) – C Where: Ca = Current Assets Cl = Current Liabilities C = Value Of All Outstanding Or Uncompleted Portions Of The Projects Under Going Contracts, Including Awarded Contracts Yet To Be Started Coinciding With The Contract For This Project Note: The Values Of The Bidder’s Current Assets And Current Liabilities Shall Be Based On The Audited Financial Statement Submitted To The Bir. Issued This _______day Of __________2025. _______________________________________________ Name & Signature Of Authorized Representative ____________________ Position _______________ Date Company Letterhead Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 Bid Form Date: Invitation To Bid No: Bid 2024-08 To: Mr. Tracy B. Soriano, Msca Bac Chairperson Leyte Regional Prison Abuyog, Leyte Gentlemen And/or Ladies: Having Examined The Bidding Documents Including Bid Bulletin Numbers Bid2024-08, The Receipt Of Which Is Hereby Duly Acknowledged, We, The Undersigned, Offer To Supply & Deliver Of Medical Supplies 2025 In Conformity With The Said Bidding Documents For The Sum Of __________________________________________₱ ________ Or Such Other Sums As May Be Ascertained In Accordance With The Schedule Of Prices Attached Herewith And Made Part Of This Bid. We Undertake, If Our Bid Is Accepted, To Deliver The Goods In Accordance With The Delivery Schedule Specified In The Schedule Of Requirements. If Our Bid Is Accepted, We Undertake To Provide A Performance Security In The Form, Amounts, And Within The Times Specified In The Bidding Documents. Until A Formal Contract Is Prepared And Executed, This Bid, Together With Your Written Acceptance Thereof And Your Notice Of Award, Shall Be Binding Upon Us. We Understand That You Are Not Bound To Accept The Lowest Calculated Bid Or Any Bid You May Receive. We Certify/confirm That We Comply With The Eligibility Requirements Of The Bidding Documents. I/we Likewise Certify/confirm That The Undersigned, [for Sole Proprietorships, Insert]: As The Owner And Sole Proprietor Or Authorized Representative Of [name Of Bidder], Has The Full Power And Authority To Participate, Submit The Bid, And To Sign And Execute The Ensuing Contract, On The Latter’s Behalf For The Supply & Delivery Of Medical Supplies 2025. We Acknowledge That Failure To Sign Each And Every Page Of This Bid Form, Including The Attached Schedule Of Prices, Shall Be A Ground For The Rejection Of Our Bid. Dated This ________________ Day Of ________________ 20______. [signature] [in The Capacity Of] Duly Authorized To Sign Bid For And On Behalf Of ____________________________ Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 Schedule Of Prices Qty. Unit Of Issue Agency Specification Abc Unit Price Total Bid Price Inclusive Of Vat 3 Pcs Acid Fast Stain, Medic (ziel-neelsen Hot Method) 12,441.00 5 Pcs Acepto Bulb Syringe 350.00 5 Pcs Adult Pulse Oximeter Fingertip (durable) 10,500.00 100 Gallon Alcohol 70% Gallon 42,000.00 10 Set Aneroid Sphygmomanometer W/ Stethoscope (durable) 39,000.00 50 Pieces Battery Double Aa (heavy Duty) 5,400.00 50 Capsule Battery Triple Aaa (heavy Duty) 5,400.00 1 Box Blood Collection Tube 5ml (lavender) 130.00 1 Box Blood Collection Tube 5ml (yellow) 1,200.00 5 Pieces Cold Compress Bag 720.00 2 Gallon Denatured Alcohol 1l 1,200.00 10 Litrs Disinfectant Solution 21,600.00 1000 Unit Drug Testing Kit (urine) 108,000.00 500 Pieces Dsn 10cc 5,000.00 700 Pieces Dsn 3cc 4,900.00 [signature] [in The Capacity Of] Duly Authorized To Sign Bid For And On Behalf Of ____________________________ Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 Schedule Of Prices Qty. Unit Of Issue Agency Specification Abc Unit Price Total Bid Price Inclusive Of Vat 700 Pieces Dsn 5cc 5,600.00 500 Pieces Dsn 1cc 3,500.00 20 Bottle Easy Touch Blood Glucose Strips 25's 20,400.00 30 Bottle Easy Touch Blood Cholesterol Strips 25's 30,600.00 30 Bottle Easy Touch Blood Uric Strips 25's 30,600.00 100 Box Examination Disposable Latex Gloves Powder Free 42,000.00 100 Box Face Mask 50's 9,600.00 20 Pieces Heplock 360.00 10 Pieces Hot Water Bag 1,080.00 20 Pieces Hydrogen Peroxide 10 Volume 2,640.00 500 Pieces Iv Infusion Set Adult 25,000.00 4 Pieces Kidney Basin Stainless 2,976.00 50 Pieces Lubricating Jelly 80gms 4,200.00 5 Pieces Medical Penlight 3,000.00 5 Pcs Medical Oxygen Regulator 12,000.00 [signature] [in The Capacity Of] Duly Authorized To Sign Bid For And On Behalf Of ____________________________ Supply & Delivery Of Medical Supplies For Cy 2025 Bid Reference No.: Bid2024-08 Schedule Of Prices Qty. Unit Of Issue Agency Specification Abc Unit Price Total Bid Price Inclusive Of Vat 50 Gallon Muriatic Acid Solution 15,000.00 30 Gallon Na Hypochlorite Solution 9,000.00 2 Set Nebulizer 3,840.00 50 Bottle One Touch Select Simple Test Strip 25's 51,000.00 150 Pieces Oxygen Mask Cannula 11,700.00 2 Pieces Oxygen Trolley (5-20 Lbs) 8,400.00 100 Pieces Petroleum Jelly 25gms 7,200.00 3 Pieces Plastic Canister 3,600.00 10 Pieces Plastic Splint Adult 10,800.00 50 Pieces Rotahaler 6,000.00 20 Set Sphygmomanometer Valve With Bulb 6,520.00 5 Box Sterile Latex Surgical Gloves #7, 50pairs/box 4,500.00 5 Pcs Soluset Infusion Set 500.00 10 Pieces Urinal (male) 1,020.00 1000 Pieces Urine Container 50ml 6,000.00 Total Bid Price Inclusive Of Vat In Words [signature] [in The Capacity Of] Duly Authorized To Sign Bid For And On Behalf Of ____________________________ Special Conditions Of Contract Gcc Clause 1 Delivery And Documents – Delivery Of The Goods Shall Be Made By The Supplier In Accordance With The Terms Specified In Section Vi. Schedule Of Requirements. Upon Delivery Of The Goods To The Project Site, The Supplier Shall Notify The Procuring Entity And Present The Following Documents To The Procuring Entity: (i) Original And Four Copies Of The Supplier’s Invoice Showing Goods’ Description, Quantity, Unit Price, And Total Amount; (ii) Delivery Receipt Detailing Number And Description Of Items Received Signed By The Procuring Entity’s Representative At The Project Site; (iii)certificate Of Acceptance/inspection Report Signed By The Procuring Entity’s Representative At The Project Site; For Purposes Of The Contract, “exw (extra Work),” “fob (“free On Board” Shipping Point),” “fca (“free Carrier” Shipping Point),” “cif (cost Insurance And Freight.),” “cip (carriage And Insurance Paid),” “ddp (delivered Duty Paid)” And Other Trade Terms Used To Describe The Obligations Of The Parties Shall Have The Meanings Assigned To Them By The Current Edition Of Incoterms Published By The International Chamber Of Commerce, Paris. The Delivery Terms Of This Contract Shall Be As Follows: The Delivery Terms Applicable To This Contract Are Ddp Delivered To Supply Office, Leyte Regional Prison, Abuyog, Leyte. Risk And Title Will Pass From The Supplier To The Procuring Entity Upon Receipt And Final Acceptance Of The Goods At Their Final Destination.” Delivery Of The Goods Shall Be Made By The Supplier In Accordance With The Terms Specified In Section Vi (schedule Of Requirements). For Purposes Of This Clause The Procuring Entity’s Representative At The Project Site Is The Lrp Health And Welfare Services Section Chief As The End-user. All Medical Supplies Must Be Delivered On Working Days And Not Later Than 1:00pm, Forty-five (45) Calendar Days From The Receipt Of Notice To Proceed. Incidental Services – The Supplier Is Required To Provide All Of The Following Services, Including Additional Services, If Any, Specified In Section Vi. Schedule Of Requirements: The Contract Price For The Goods Shall Include The Prices Charged By The Supplier For Incidental Services And Shall Not Exceed The Prevailing Rates Charged To Other Parties By The Supplier For Similar Services. Packaging – The Supplier Shall Provide Such Packaging Of The Goods As Is Required To Prevent Their Damage Or Deterioration During Transit To Their Final Destination, As Indicated In This Contract. The Packaging Shall Be Sufficient To Withstand, Without Limitation, Rough Handling During Transit And Exposure To Extreme Temperatures, Salt And Precipitation During Transit, And Open Storage. Packaging Case Size And Weights Shall Take Into Consideration, Where Appropriate, The Remoteness Of The Goods’ Final Destination And The Absence Of Heavy Handling Facilities At All Points In Transit. The Packaging, Marking, And Documentation Within And Outside The Packages Shall Comply Strictly With Such Special Requirements As Shall Be Expressly Provided For In The Contract, Including Additional Requirements, If Any, Specified Below, And In Any Subsequent Instructions Ordered By The Procuring Entity. The Outer Packaging Must Be Clearly Marked On At Least Four (4) Sides As Follows: Name Of The Procuring Entity Name Of The Supplier Contract Description Final Destination Gross Weight Any Special Lifting Instructions Any Special Handling Instructions Any Relevant Hazchem Classifications A Packaging List Identifying The Contents And Quantities Of The Package Is To Be Placed On An Accessible Point Of The Outer Packaging If Practical. If Not Practical The Packaging List Is To Be Placed Inside The Outer Packaging But Outside The Secondary Packaging. Additional Requirements On Box Or Bottle, Blister Packs, Inhaler And Tube. The Following Is Legibly Imprinted Or Stamped In Any Color. Date Of Manufacture __________________ Date Of Expiry ___________________ Transportation – Where The Supplier Is Required Under Contract To Deliver The Goods Cif (cost Insurance And Freight.), Cip (carriage And Insurance Paid), Or Ddp (delivered Duty Paid), Transport Of The Goods To The Port Of Destination Or Such Other Named Place Of Destination In The Philippines, As Shall Be Specified In This Contract, Shall Be Arranged And Paid For By The Supplier, And The Cost Thereof Shall Be Included In The Contract Price. Where The Supplier Is Required Under This Contract To Transport The Goods To A Specified Place Of Destination Within The Philippines, Defined As The Project Site, Transport To Such Place Of Destination In The Philippines, Including Insurance And Storage, As Shall Be Specified In This Contract, Shall Be Arranged By The Supplier, And Related Costs Shall Be Included In The Contract Price. Where The Supplier Is Required Under Contract To Deliver The Goods Cif (cost Insurance And Freight.), Cip (carriage And Insurance Paid), Or Ddp (delivered Duty Paid), Goods Are To Be Transported On Carriers Of Philippine Registry. In The Event That No Carrier Of Philippine Registry Is Available, Goods May Be Shipped By A Carrier Which Is Not Of Philippine Registry Provided That The Supplier Obtains And Presents To The Procuring Entity Certification To This Effect From The Nearest Philippine Consulate To The Port Of Dispatch. In The Event That Carriers Of Philippine Registry Are Available But Their Schedule Delays The Supplier In Its Performance Of This Contract The Period From When The Goods Were First Ready For Shipment And The Actual Date Of Shipment The Period Of Delay Will Be Considered Force Majeure. The Procuring Entity Accepts No Liability For The Damage Of Goods During Transit Other Than Those Prescribed By Incoterms For Ddp Deliveries. In The Case Of Goods Supplied From Within The Philippines Or Supplied By Domestic Suppliers Risk And Title Will Not Be Deemed To Have Passed To The Procuring Entity Until Their Receipt And Final Acceptance At The Final Destination. Intellectual Property Rights – The Supplier Shall Indemnify The Procuring Entity Against All Third-party Claims Of Infringement Of Patent, Trademark, Or Industrial Design Rights Arising From Use Of The Goods Or Any Part Thereof. 2.1 Partial Payment Is Not Allowed 4 The Inspections And Tests That Will Be Conducted Are: Partial/complete Delivery Of Goods Shall Be Inspected By The Lrp Inspection And Acceptance Committee. Inspection And Acceptance Will Be Conducted By The Lrp Inspection And Acceptance Committee To The Actual Delivery At The Project Site (lrp). Goods With Defect Or Non-compliant With The Required Specifications As Stipulated In The Approved Purchase Order/technical Specifications Shall Be Rejected And Shall Be Replaced By The Supplier Free Of Cost To The Procuring Entity Within Seven (7) Calendar Days The Goods Shall Be Accepted By The End User After Passing The Inspection Of The Lrp Inspection And Acceptance Committee. The Inspections And Tests That Will Be Conducted Are; 1.) Upon Delivery, The Goods Shall Undergo Physical Inspection By The Lrp Inspection And Acceptance Committee Of The Procuring Entity To Ascertain The Physical Condition And Acceptability Of The Goods. 2.) Actual Counting Inspection To Determine The Quantity And Completeness Of The Medical Supplies Delivered In Accordance To The Schedule Of Requirements Set In The Bidding Documents.
NATIONAL AERONAUTICS AND SPACE ADMINISTRATION USA Tender
Others
United States
Closing Date16 Jan 2027
Tender AmountRefer Documents
Details: This Is A Modification 6 To The Synopsis Entitled Extravehicular Activity And Human Surface Mobility Technologies, Reference No. 80jsc022ehp Which Was Posted On September 23, 2022. You Are Notified That The Following Changes Are Made: purpose: extended The Response Date From 1/16/2025 To 1/16/2027. the Due Date For Responses Is Extended. offerors Are Responsible For Monitoring This Site For The Release Of The Solicitation And Any Amendments. Potential Offerors Are Responsible For Downloading Their Own Copy Of The Solicitation And Amendments. ***end Of Modification 6*** this Is A Modification 5 To The Synopsis Entitled Extravehicular Activity And Human Surface Mobility Technologies, Reference No. 80jsc022ehp Which Was Posted On September 23, 2022. You Are Notified That The Following Changes Are Made: purpose: this Is A Modification 5 To Update The Point Of Contact (poc) From: contact Information:
technology Development And Partnerships Manager,
eva & Human Surface Mobility Program
email: Michael.a.berdich@nasa.gov to: contact Information:
technology Development And Partnerships Manager,
eva & Human Surface Mobility Program
email: Stephanie.a.sipila@nasa.gov the Due Date For Responses Is Not Extended. offerors Are Responsible For Monitoring This Site For The Release Of The Solicitation And Any Amendments. Potential Offerors Are Responsible For Downloading Their Own Copy Of The Solicitation And Amendments. ***end Of Modification 5*** this Is A Modification 4 To The Synopsis Entitled Extravehicular Activity And Human Surface Mobility Technologies, Reference No. 80jsc022ehp Which Was Posted On September 23, 2022. You Are Notified That The Following Changes Are Made: correct The Modification 3 revise The Entry Titled “modification 2” To Reflect It As “modification 1.” Additionally, Incorporate Relevant Links In Bold Into This Entry. the Following Link Https://nasajsc.secure.force.com/statementofinterest Is No Longer Valid Please Refer To The Link Below Titled: The Statement Of Interest In The Attachments/links Section. purpose:
the Nasa Extravehicular Activity (eva) And Human Surface Mobility (hsm) Program (ehp) Seeks To Work With Partners To Advance The Technologies Associated With Human Surface Mobility In Support Of Nasa’s Artemis Missions. The Ehp Vision Is To Provide Safe, Reliable, And Effective Eva And Hsm Capabilities That Allow Astronauts To Survive And Work Outside The Confines Of A Spacecraft On And Around The Moon. Artemis Missions Will Return Humans To The Surface Of The Moon Using Innovative Technologies To Explore More Of The Lunar Surface Than Ever Before. We Will Collaborate With Commercial And International Partners And Establish The First Long-term Presence On The Moon. Then, We Will Use What We Learn On And Around The Moon To Take The Next Giant Leap: Sending The First Astronauts To Mars. ehp Flight Projects Are Exploration Eva Suits (xeva Suits) And Tools, Lunar Terrain Vehicle (ltv), And Pressurized Rover (pr). For More Information, Reference The Ehp Website Here: Extravehicular Activity And Human Surface Mobility - Nasa (https://www.nasa.gov/extravehicular-activity-and-human-surface-mobility/). the Ehp And Partners Will Collaborate On Developing Lunar Surface Capabilities To Reduce Risk And Increase Productivity Of Ehp Flight Projects During Artemis Missions. Focus Will Be On Technologies That Mitigate Risk For Lunar Surface Systems That Will Provide Mission Planners With More Choices, Thereby Increasing Mission Success. In Pursuing These Types Of Capabilities, Nasa And Potential Partners Will Develop New And Improved Technologies That Will Provide Additional Options For Terrestrial Applications In Multiple Industries. additional Information:
ehp May Periodically Publish In Appendices To This Announcement Identifying Specific Technologies Under Current Development To Further Inform Potential Collaboration Opportunities. An Example Of One Such Technology Being Developed Is Described In Appendix A - Lunar Dust Level Sensor And Effects On Surfaces (ldes). For Access To This Export-controlled Document, Please Email The Points Of Contact Below. ehp Periodically Places Informational Reference Documents That Relate To Lunar Human Surface Mobility Accessible By Industry In The Ehp Technical Library (https://eva.jsc.nasa.gov/). Access To The Technical Library Requires Login.gov Access. Follow The Prompts To Gain Access. Once Access Has Been Granted, The Informational Documents Related To This Announcement Is In The ‘ehp Technology Integration’ Folder, In Which You Will Find Information On The Following (major Updates To The Technical Library Content Will Also Be Updated Here):
- Ldes – Initial Ground Test Results Regarding The Magnitude Of Thermal Impact That Lunar Dust Has On Surfaces.
- 84s Lunar Terrain Model – A Terrain Model Of The Lunar South Pole (below The 84 South Latitude) Which Can Be Used As An Early Reference Data Set To Enable Initial Studies Of The Lunar Terrain. additionally, Nasa Has Made Available To The Public The Digital Lunar Exploration Sites Unreal Simulation Tool (dust) Which Is An Early 3d Visualization Application Of The Lunar South Pole. Its Intended Use Is For Early Inspection, Mission Planning, And Analysis Of Lunar Landing And Traverse Sites For Hls And Artemis Base Camp. This Application And The Supporting Toolkit Built From Dust Are Used To Provide Distributable Lunar Environments And Tools To Support Rendering And Exporting Terrain, Multi-display Facilities, And Connections To Trick-based Simulations. It Can Be Attained At The Following Link: Digital Lunar Exploration Sites Unreal Simulation Tool (dust) Products(msc-27522-1) | Nasa Software Catalog (https://software.nasa.gov/software/msc-27522-1). technology:
ehp Technology Goals Include, But Are Not Limited To, Overcoming Environmental And Long Mission Duration Challenges. Lunar Environmental Challenges Include Operating In Dust (lunar Regolith), Radiation, And Extreme Temperatures. Martian Environmental Challenges Are Operating In Martian Carbon Dioxide-rich Atmosphere And 1/3g, Driving The Need For Low Size, Weight, And Power. Long Mission Durations Drive Sustainability And Maintainability Challenges. Some Technology Areas Of Interest Include, But Are Not Limited To: Dust Mitigation Capabilities, Eva Systems, Local Relative Navigation, Increased Battery Capacity And Reduced Charge Time, And Advanced Mobility Concepts Capable Of Sustained Operation While Minimizing Maintenance In A Lunar Environment For An Extended Service Period. Each System Will Be Required To Operate In The Extreme Environment Of Cis-lunar Orbit And/or The Lunar South Pole, Including Inside Permanently Shadowed Regions (psrs) And Onto Mars. intellectual Property (ip): this Potential Partnership May Produce New Ip That Could Be Jointly Owned By Nasa And The Partner Or May Become The Property Of The Partner. Standard Clauses For Partnership Agreements Are Provided In The Appendices Of The Space Act Agreements Guide, Naii 1050-1. These Standard Clauses Are Usually Used Without Any Changes. Any Deviations From The Standard Intellectual Property Clauses Are Reviewed By Nasa Office Of The General Counsel At The Headquarters And/or Center-level, As Appropriate And Approved By Nasa Partnerships Office. potential Commercial Applications:
lunar, Undersea, Automotive, Nuclear, Space Tourism, Personal Protective Equipment (ppe) … keywords:
mobility, Spacesuit, Rover, Vehicle, Power Infrastructure, Sustainable, Dust, Communication Architecture, Relative Navigation And Localization, Regolith, Lunar Terrain Vehicle, Ltv, Pressurized Rover, Pr, Lunar, Artemis, Moon, Iss, Leo contact Information:
technology Development And Partnerships Manager,
eva & Human Surface Mobility Program
email: Michael.a.berdich@nasa.gov partnership Manager,
jsc’s Partnership Development Office
email: Jsc-partnerships@mail.nasa.gov to Respond To This Announcement, Please Use The Statement Of Interest Form Found At
statement Of Interest (https://docs.google.com/forms/d/e/1faipqlsclwzeqitigc1wauvfvegkykseuozom0uofxtc60gk_giretq/viewform?usp=sharing) to View All Co-development And Partnering Opportunities With The Nasa Johnson Space Center, Please Visit Our Website At
(https://www.nasa.gov/johnson/exploration/technology/co-development-and-partnering-opportunities) the Due Date For Responses Is Not Extended.
offerors Are Responsible For Monitoring This Site For The Release Of The Solicitation And Any Amendments. Potential Offerors Are Responsible For Downloading Their Own Copy Of The Solicitation And Amendments. ***end Of Modification 4*** this Is A Modification 3 To The Synopsis Entitled Extravehicular Activity And Human Surface Mobility Technologies, Reference No. 80jsc022ehp Which Was Posted On September 23, 2022. You Are Notified That The Following Changes Are Made: update Modifcation 2 In Its Entirety: purpose: the Nasa Extravehicular Activity (eva) And Human Surface Mobility (hsm) Program (ehp) Seeks To Work With Partners To Advance The Technologies Associated With Human Surface Mobility In Support Of Nasa’s Artemis Missions. The Ehp Vision Is To Provide Safe, Reliable, And Effective Eva And Hsm Capabilities That Allow Astronauts To Survive And Work Outside The Confines Of A Spacecraft On And Around The Moon. Artemis Missions Will Return Humans To The Surface Of The Moon Using Innovative Technologies To Explore More Of The Lunar Surface Than Ever Before. We Will Collaborate With Commercial And International Partners And Establish The First Long-term Presence On The Moon. Then, We Will Use What We Learn On And Around The Moon To Take The Next Giant Leap: Sending The First Astronauts To Mars. ehp Flight Projects Are Exploration Eva Suits (xeva Suits) And Tools, Lunar Terrain Vehicle (ltv), And Pressurized Rover (pr). For More Information, Reference The Ehp Website Here: Extravehicular Activity And Human Surface Mobility - Nasa the Ehp And Partners Will Collaborate On Developing Lunar Surface Capabilities To Reduce Risk And Increase Productivity Of Ehp Flight Projects During Artemis Missions. Focus Will Be On Technologies That Mitigate Risk For Lunar Surface Systems That Will Provide Mission Planners With More Choices, Thereby Increasing Mission Success. In Pursuing These Types Of Capabilities, Nasa And Potential Partners Will Develop New And Improved Technologies That Will Provide Additional Options For Terrestrial Applications In Multiple Industries. additional Information: ehp May Periodically Publish In Appendices To This Announcement Identifying Specific Technologies Under Current Development To Further Inform Potential Collaboration Opportunities. An Example Of One Such Technology Being Developed Is Described In Appendix A - Lunar Dust Level Sensor And Effects On Surfaces (ldes). For Access To This Export Controlled Document, Please Email The Points Of Contact Below. ehp Periodically Places Informational Reference Documents That Relate To Lunar Human Surface Mobility Accessible By Industry In The Ehp Technical Library. Access To The Technical Library Requires Login.gov Access. Follow The Prompts To Gain Access. Once Access Has Been Granted, The Informational Documents Related To This Announcement Is In The ‘ehp Technology Integration’ Folder, In Which You Will Find Information On The Following (major Updates To The Technical Library Content Will Also Be Updated Here): ldes – Initial Ground Test Results Regarding The Magnitude Of Thermal Impact That Lunar Dust Has On Surfaces. 84s Lunar Terrain Model – A Terrain Model Of The Lunar South Pole (below The 84 South Latitude) Which Can Be Used As An Early Reference Data Set To Enable Initial Studies Of The Lunar Terrain. additionally, Nasa Has Made Available To The Public The Digital Lunar Exploration Sites Unreal Simulation Tool (dust) Which Is An Early 3d Visualization Application Of The Lunar South Pole. Its Intended Use Is For Early Inspection, Mission Planning, And Analysis Of Lunar Landing And Traverse Sites For Hls And Artemis Base Camp. This Application And The Supporting Toolkit Built From Dust Are Used To Provide Distributable Lunar Environments And Tools To Support Rendering And Exporting Terrain, Multi-display Facilities, And Connections To Trick-based Simulations. It Can Be Attained At The Following Link: Digital Lunar Exploration Sites Unreal Simulation Tool (dust) Products(msc-27522-1) | Nasa Software Catalog. technology:
ehp Technology Goals Include, But Are Not Limited To, Overcoming Environmental And Long Mission Duration Challenges. Lunar Environmental Challenges Include Operating In Dust (lunar Regolith), Radiation, And Extreme Temperatures. Martian Environmental Challenges Are Operating In Martian Carbon Dioxide-rich Atmosphere And 1/3g, Driving The Need For Low Size, Weight, And Power. Long Mission Durations Drive Sustainability And Maintainability Challenges. Some Technology Areas Of Interest Include, But Are Not Limited To: Dust Mitigation Capabilities, Eva Systems, Local Relative Navigation, Increased Battery Capacity And Reduced Charge Time, And Advanced Mobility Concepts Capable Of Sustained Operation While Minimizing Maintenance In A Lunar Environment For An Extended Service Period. Each System Will Be Required To Operate In The Extreme Environment Of Cis-lunar Orbit And/or The Lunar South Pole, Including Inside Permanently Shadowed Regions (psrs) And Onto Mars. intellectual Property (ip): this Potential Partnership May Produce New Ip That Could Be Jointly Owned By Nasa And The Partner Or May Become The Property Of The Partner. Standard Clauses For Partnership Agreements Are Provided In The Appendices Of The Space Act Agreements Guide, Naii 1050-1. These Standard Clauses Are Usually Used Without Any Changes. Any Deviations From The Standard Intellectual Property Clauses Are Reviewed By Nasa Office Of The General Counsel At The Headquarters And/or Center-level, As Appropriate And Approved By Nasa Partnerships Office. potential Commercial Applications: lunar, Undersea, Automotive, Nuclear, Space Tourism, Personal Protective Equipment (ppe) … keywords: mobility, Spacesuit, Rover, Vehicle, Power Infrastructure, Sustainable, Dust, Communication Architecture, Relative Navigation And Localization, Regolith, Lunar Terrain Vehicle, Ltv, Pressurized Rover, Pr, Lunar, Artemis, Moon, Iss, Leo contact Information: technology Development And Partnerships Manager, eva & Human Surface Mobility Program email: Michael.a.berdich@nasa.gov partnership Manager, jsc’s Partnership Development Office email: Jsc-partnerships@mail.nasa.gov to Respond To This Announcement, Please Use The Statement Of Interest Form Found At statementofinterest to View All Co-development And Partnering Opportunities With The Nasa Johnson Space Center, Please Visit Our Website At https://www.nasa.gov/johnson/exploration/technology/co-development-and-partnering-opportunities extended The Response Date From 9/26/2024 To 1/16/2025 the Due Date For Responses Is Extended. offerors Are Responsible For Monitoring This Site For The Release Of The Solicitation And Any Amendments. Potential Offerors Are Responsible For Downloading Their Own Copy Of The Solicitation And Amendments. ***** End Of Modification 3**** this Is A Modification 2 To The Synopsis Entitled Extravehicular Activity And Human Surface Mobility Technologies, Reference No. 80jsc022ehp Which Was Posted On September 23, 2022. You Are Notified That The Following Changes Are Made: extended The Response Date From 9/26/2023 To 9/26/2024 the Due Date For Responses Is Extended. offerors Are Responsible For Monitoring This Site For The Release Of The Solicitation And Any Amendments. Potential Offerors Are Responsible For Downloading Their Own Copy Of The Solicitation And Amendments. *****end Of Modiffication 2 ****** this Is A Modification 1 To The Synopsis Entitled Extravehicular Activity And Human Surface Mobility Technologies, Reference No. 80jsc022ehp Which Was Posted On September 23, 2022. You Are Notified That The Following Changes Are Made: new Attachment: Appendix A – Lunar Dust Level Sensor And Effects On Surfaces new Purpose Statement Added In Bold. the Due Date For Responses Is Not Extended. offerors Are Responsible For Monitoring This Site For The Release Of Any New Special Notice. purpose:
the Nasa Extravehicular Activity (eva) And Human Surface Mobility (hsm) Program (ehp) Seeks To Work With Partners To Advance The Technologies Associated With Human Mobility And Lunar Surface Infrastructure In Support Of Nasa’s Artemis Missions. The Ehp Vision Is To Provide Safe, Reliable, And Effective Eva And Hsm Capabilities That Allow Astronauts To Survive And Work Outside The Confines Of A Spacecraft On And Around The Moon. Artemis Missions Will Return Humans To The Surface Of The Moon Using Innovative Technologies To Explore More Of The Lunar Surface Than Ever Before. We Will Collaborate With Commercial And International Partners And Establish The First Long-term Presence On The Moon. Then, We Will Use What We Learn On And Around The Moon To Take The Next Giant Leap: Sending The First Astronauts To Mars. the Ehp And Partners Will Collaborate On Developing Lunar Capabilities To Increase Productivity Of Relevant Systems Allowing Crew To Accomplish More During Artemis Missions. Focus Will Be On High-risk Technologies For Lunar Surface Systems That Will Provide Mission Planners With More Choices, Thereby Increasing Mission Success. In Pursuing These Types Of Capabilities, Nasa And Potential Partners Will Develop New And Improved Technologies That Will Provide Additional Options For Terrestrial Applications In Multiple Industries. ehp May Periodically Publish In Appendices To This Announcement Identifying Specific Technologies Under Current Development To Further Inform Potential Collaboration Opportunities. An Example Of One Such Technology Being Developed Is Described In Appendix A - Lunar Dust Level Sensor And Effects On Surfaces (ldes).for Access To This Export Controlled Document, Please Email The Points Of Contact Below. technology:
technology Goals Include, But Are Not Limited To: Dust Mitigation Capabilities, Eva Systems, Lunar Power And Communication Infrastructure, Local Relative Navigation, Increased Battery Capacity And Reduced Charge Time, And Advanced Mobility Concepts Capable Of Sustained Operation While Minimizing Maintenance In A Lunar Environment For An Extended Service Period. Each System Will Be Required To Operate In The Extreme Environment Of Cis-lunar Orbit And/or The Lunar South Pole, Including Inside Permanently Shadowed Regions (psrs) And Onto Mars. intellectual Property (ip): this Potential Partnership May Produce New Ip That Could Be Jointly Owned By Nasa And The Partner Or May Become The Property Of The Partner. Standard Clauses For Partnership Agreements Are Provided In The Appendices Of The Space Act Agreements Guide, Naii 1050-1. These Standard Clauses Are Usually Used Without Any Changes. Any Deviations From The Standard Intellectual Property Clauses Are Reviewed By Nasa Office Of The General Counsel At The Headquarters And/or Center-level, As Appropriate And Approved By Nasa Partnerships Office. potential Commercial Applications:
lunar, Undersea, Automotive, Nuclear, Space Tourism, Personal Protective Equipment (ppe) … keywords:
mobility, Spacesuit, Rover, Vehicle, Power Infrastructure, Sustainable, Dust, Communication Architecture, Relative Navigation And Localization, Regolith, Lunar Terrain Vehicle, Ltv, Pressurized Rover, Pr, Lunar, Artemis, Moon, Iss, Leo to Respond To This Announcement, Please Use The Statement Of Interest Form Found At The Link Below. to View All Co-development And Partnering Opportunities With The Nasa Johnson Space Center, Please Visit Our Website At
https://www.nasa.gov/johnson/exploration/technology/co-development-and-partnering-opportunities
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Others
United States
Closing Soon10 Jan 2025
Tender AmountRefer Documents
Details: Page 9 Of30 statement Of Work louis A. Johnson Va Medical Center contractor Shall Provide All Labor, Parts And Transportation To Provide Inspection, Function Testing, Maintenance And 24 Hour Emergency Repairs To The Fixed Fire Protection System, Fire Extinguishers, Emergency Lights, Emergency Showers And Eye-wash Stations And Other Life-safety Equipment And Systems At The Louis A. Johnson Va Medical Center Campus, Located In Clarksburg, Wv And At The Tucker County Community Based Outreach Center (cboc), Located In Parsons, Wv And The Wood County Community Based Outreach Center (cboc), Located In Parkersburg, Wv And Braxton County Community Based Outreach Center (cboc), Located In Flatwoods, Wv And Monongalia County Community Based Outreach Center (cboc) And Monongalia County Veterans Outreach Center, Located In Westover, Wv And Rosebud Facility Located In Clarksburg, Wv. The Work For This Portion Of The Contract Includes The Following: contractor Shall Be Responsible For All Above-ground Portions Of The Fixed Fire Protection System In The Hospital, All Out-buildings And Hospital Grounds. annual Full Maintenance On Ten (11) Wet Pipe Fire Sprinkler Systems. 3 In Main Building, 2 In Bldg. 2, 2 In Bldg. 7, 2 In Bldg. 20, 1 In Bldg. 5, 1 In Bldg. 22. annual Dry Sprinkler Trip Test On, (5) Dry Sprinkler Systems (1) In Main Building, (1) In Ca, (1) In Building 6, (1) In Building 20. (1) In Building 22. Full Flow Trip Test Will Be Conducted At Least Every Third Year. annual Trip Test Of (1) Pre-action System In Clinical Addition Mri. All Devices Associated With The Pre-action System Will Be Tested Annually. quarterly Testing Of Supervisory Signals (3) Low Air Low Devices (1) In The Penthouse, (1) In Room B202, (1) In Bldg. 6. quarterly Inspections Of Each Additional Floor Control Assembly Inspection (all Tampers And Alarming Devices) Valves Will Be Fully Exercised Annually To Operate The Tamper Switch. Flow And Pressure Switches Will Be Operated With Water Flow When Possible. Building 1 (48) Tamper And
(35) Alarming Devices, Ca (28) Tamper And (20) Alarming Devices, Building 5 (3) Tamper And (1)
alarming Device, Building 6 (1) Tamper And (1) Alarming Device, Building 7 (3) Tamper And (2)
alarming Device, Building 20 (6) Tamper And (3) Alarming Device. Building 22 (4) Tampers And (2) Alarming Devices. supervisory Alarm Other Than Tamper Switches Will Be Tested Quarterly. Building I (2), Building 2 (2), Building 6 (1), Building 22 (2) annual Test Of (4) Antifreeze Systems In Main Building (1) At The Northwest Entrance, (1) On Old Dock Area, (1) In Biomedical Engineering And (1) In Ambulance Bay. Conducted Prior To Freezing Weather. quarterly Inspection For The Post Indicator Valves (7). (3) For Main Building, (2) For Ca, (1) For Building 6, (1) For Building 7. Fully Exercise Valves At Least Annually. quarterly Inspection For The Wall Post Indicator Valves (1) For Building 20 And (1) For Bldg. 22. Fully Exercise Valve At Least Annually. quarterly Inspection Of (7) Fire Department Connections (3) For Bldg. I, (2) For Bldg. 2, (1) For Bldg. 6, (1) For Bldg. 7, (1) For Bldg. 22. annual Private Yard Hydrant Flow Test, (5). Flow Test Must Be Conducted After 14:00 So Not To Interfere With Laundry Service. annual Inspection And Testing Of (42) Backflow Preventer. annual Testing And Inspection Of All Facility Fire Doors (campus Wide) (250 Total) four (4) Kitchen Fire Suppression Systems Semi-annual Inspections (includes Changing Up To Three Fusible Links Per System Annually, Must Have Current Date Stamped On Links). Provide Hood And Duct Cleaning On A Semi-annual Basis As Required Nfpa 17a. In The Following Locations (1) Dietary Kitchen, (2) Canteen Service And (1) In Building 20. monthly And Annual Inspections Of 210 Portable Fire Extinguishers At The Medical Center Campus; Including Annual Inspection, Tags, And Recharge For Each Extinguisher. Annual And Monthly Inspection Cannot Be Combined On The Inspection Tag. monthly Test Of The 21 Eye Wash Stations And 1 Emergency Showers/eye Wash Combo. Report Will Include Valve Operation, Flow Rates And Temperature.
annual Testing Of 21 Eye Wash Stations And 1 Emergency Showers/eye Wash Combo According To The Manufacturer's Inspection Procedures To Ensure Continued Conformance With American National Standards Institute (ansi) 358.1 And Maintaining A Written Record Of The Procedures Used And The Testing Date. The Va Will Provide What Will Be Required To Meet Ansi 358.1 Standard.
monthly Testing And Maintenance On Approximately 95 Emergency Lights At The Medical Center Campus. Annual And Monthly Testing Will Follow The Current Nfpa 101 Periodic Testing Of Emergency Lighting Equipment Code. Annual Test Will Include New Annual Test Stickers. Battery Replacement Will Be The Responsibility Of The Contractor. monthly Testing Of The Firefighter Recalls For All Elevators. Testing Will Follow Asme Al 7.1 Standards. Three (3) Elevators Are Located In Bldg. 1, Three (3) In Clinical Addition, And One (1) In Bldg. 20. contractor Shall Be Responsible For Development Of A Full Inventory Of All Inspected Devices That Will Include A Unique Identifier For Each, Its Location, Inspection Frequency And Device Type. community Based Outreach Center And Rosebud Facility annual Full Maintenance On (1) Wet Sprinkler Risers At Mon Co. Cboc And Rosebud Facility. quarterly Testing Of Water Flow And Tampers Devices At The Mon Co. Cboc And Rosebud Facility. Valves Will Be Fully Exercised Annually To Operate The Tamper Switch. Flow And Pressure Switches Will Be Operated With Water Flow When Possible. quarterly Inspection Of (1) Fire Department Connections At Rosebud Facility. monthly Inspection Of Eyewash Stations In Each Cboc Location. monthly And Annual Inspection Of Approximately 40 Total Portable Fire Extinguishers At The Tucker, Braxton, Wood, And Monongalia County Cboc's, Monongalia County Veterans Outreach Center And Rosebud Combined, Including Annual Inspection, Tags. Annual And Monthly Inspection Cannot Be Combined On The Inspection Tag. annual Inspection And Full Maintenance As Well As Monthly Inspection On Approximately 80 Emergency Lights At Tucker, Braxton, Wood, And Monongalia County Cboc's, Monongalia County Veterans Outreach Center Combined. Annual And Monthly Testing Will Follow The Current Nfpa 101 Periodic Testing Of Emergency Lighting Equipment Code. Annual Test Will Include New Annual Test Stickers. Battery Replacement Will Be The Responsibility Of The Contractor. annual Testing Of Fire Alarm Systems: braxton Co. Cboc, (1) Fire Alarm Panel, (3) Manual Pull Stations, (9) Smoke Detectors, (8) Visual Horns/strobes.
wood Co. Cboc, (1) Fire Alarm Panel, (3) Manual Pull Stations, (3) Smoke Detectors,
(2) Duct Detectors, (4) Heat Detectors, (7) Horns And (3) Horn/strobes. mon Co. Cboc, (1) Fire Alarm Panel, (4) Manual Pull Stations, (4) Smoke Detectors,
(12) Speaker/strobes, tucker Cboc, (1) Fire Alarm Panel, (3) Manual Pull Station, (8) Smoke Detectors, (2) Duct Detectors, (11) Strobes And (3) Horn/strobes rosebud, (1) Fire Alarm Panel, (12) Smoke Detectors, (7) Speaker/strobes contractor Shall Be Responsible For Development Of A Full Inventory Of All Inspected Devices That Will Include A Unique Identifier For Each, Its Location, Inspection Frequency And Device Type. 24/7 Emergency Service Will Be Provided By The Contractor. The Contractor Shall Be Required To Respond By Telephone Within Two (2) Hours And Have A Service Person Onsite Within Four (4) Hours Of Being Contacted By The Department Of Veteran Affairs. the Work Included In This Item (1) Does Not Cover Hard Wiring. contractor Shall Be Responsible For All Labor, Parts, And Transportation To Provide Inspection, Maintenance And 24-hour Emergency Service To The Emergency Alarm System At The Louis A. Johnson Va Medical Center, Located In Clarksburg, Wv. The Work For This Portion Of The Contract Includes The Following; main Building- Three (3) 4100 Panels And Nine (9) 4009 Nac Power Extenders bldg. 5- One (1) 4010 Panel bldg. 7- One (1) 4010 Panel And One (1) 4009 Nac Power Extender bldg. 6 - One (1) 4010 Panel bldg. 20- One (1) Game Well Panel bldg. 22 - One (1) 4100 Panel parking Garage One (1) 4100 Panel four (4) Annunciator Led Type (aod, Operator, Main Entrance, Bp) battery Testing Will Be Required For All Panels. two (2) True Site Systems (fire Alarm Panel Room And Safety Office) forty-five (45) Initiating Devices- Duct Detectors thirty-eight (38) Initiating Devices - Heat Detectors - Non-restorable two Hundred (200) Initiating Devices - Smoke Detectors - Photoelectric (includes Sensitivity Testing And Cleaning)
one Hundred Forty-five (145) Initiating Devices - Fire Alarm Box, Manual, Un-coded. eighty (80) Alarm Notification Appliance - Fire Alarm Visual Devices. sixty (60) Alarm Notification Appliance - Fire Alarm Audio Devices. three Hundred Seventy-five (375) - Alarm Notification Appliance - Fire Alarm Audio/visual Devices. twenty-nine (29) Door Closers monthly Inspections For The Carbon Monoxide Detectors At The Medical Center (1) In Bldg. 5 24/7 Emergency Service establish And Maintain The Communications Link/ Monitoring Service Between The Medical Center Campus' Alarm Systems And The Local Fire Station On A Twenty-four-hour, Seven Day Per Week Basis. Signals Must Be Ul Listed. The Va Has Already Established Two Dedicated Lines. Quarterly Reports Must Be Furnished By The Contractor On A Separate Report With The Time, Date, And The Amount Of Time To Transmit, To Assure That The System Is Functioning. 36c24519c0060 page 10 Of30 all Necessary Programming Of Simplex Equipment To All Points. the Work Included In This Item (2) Does Not Cover Hard Wiring fire And Smoke Damper Testing: test And Inspect A Different 25% Of All Dampers Annually, 100% Will Be Tested At The End Of 4 Years, (162 Dampers Located In 2016 Are Testable). Contractor Will Spend Up To 4 Additional Hours A Year Locating Additional Dampers Missed In Previous Years. A Label Will Be Placed On The Outside Of The Damper. A Detailed Report Will Be Provided Which Will Include Photograph Of The Dampers, Open And Closed, Type Of Damper. The Va Will Provide Drawings That The Contractor Will Then Mark The Location Of The Dampers. all Inspectors On Site Will Carry A Minimum Of Nicet Level 2 For Sprinkler And Fire Alarm Inspections. there Will Be One Person Of Contact For All The Listed Locations each Report Will Be Broken Down By Building And Inspection Type. Example, Bldg. I Sprinkler, Bldg. 5 Co2, Bldg. 2 Emergency Lights each Report Is To Include The Following: unique Identifier Of Each Device Inspected In Relation To The Full Inventory List. the Results Of The Inspected Device. how Each Device Was Inspected Or Tested. a Recommendation For Correction Of Deficiency Noted. the Conclusion Of Each Inspection Is To Be Reviewed Concurrently With The Cort And Appropriate Representative From The Inspection Company. reports Will Be Electronic And Sent By E-mail At The Completion Of Each Inspection. all Work Performed Under This Contract Shall Be In Accordance With All Applicable Codes And Standards, Including But Not Limited To Nfpa, Jacho, Ansi, Asme And Va Standards. the C&a Requirements Do Not Apply. A Security Accreditation Package Is Not Required. for Emergency Repairs, The Contractor Shall Be Required To Respond By Telephone Within Two (2) Hours And Have A Service Person On-site Within Four (4) Hours Of Being Contacted By The Department Of Veteran Affairs. records Management Obligations
a. Â applicability
this Clause Applies To All Contractors Whose Employees Create, Work With, Or Otherwise Handle Federal Records, As Defined In Section B, Regardless Of The Medium In Which The Record Exists. Â
b.  definitions Federal Record As Defined In 44 U.s.c. § 3301, Includes All Recorded Information, Regardless Of Form Or Characteristics, Made Or Received By A Federal Agency Under Federal Law Or In Connection With The Transaction Of Public Business And Preserved Or Appropriate For Preservation By That Agency Or Its Legitimate Successor As Evidence Of The Organization, Functions, Policies, Decisions, Procedures, Operations, Or Other Activities Of The United States Government Or Because Of The Informational Value Of Data In Them. Â
the Term Federal Record:
includes Lajvamc Records.â
does Not Include Personal Materials.
applies To Records Created, Received, Or Maintained By Contractors Pursuant To Their Lajvamc Contract.
may Include Deliverables And Documentation Associated With Deliverables.
c. Â requirements
contractor Shall Comply With All Applicable Records Management Laws And Regulations, As Well As National Archives And Records Administration (nara) Records Policies, Including But Not Limited To The Federal Records Act (44 U.s.c. Chs. 21, 29, 31, 33), Nara Regulations At 36 Cfr Chapter Xii Subchapter B, And Those Policies Associated With The Safeguarding Of Records Covered By The Privacy Act Of 1974 (5 U.s.c. 552a). These Policies Include The Preservation Of All Records, Regardless Of Form Or Characteristics, Mode Of Transmission, Or State Of Completion.â
in Accordance With 36 Cfr 1222.32, All Data Created For Government Use And Delivered To, Or Falling Under The Legal Control Of, The Government Are Federal Records Subject To The Provisions Of 44 U.s.c. Chapters 21, 29, 31, And 33, The Freedom Of Information Act (foia) (5 U.s.c. 552), As Amended, And The Privacy Act Of 1974 (5 U.s.c. 552a), As Amended And Must Be Managed And Scheduled For Disposition Only As Permitted By Statute Or Regulation.â
in Accordance With 36 Cfr 1222.32, Contractor Shall Maintain All Records Created For Government Use Or Created In The Course Of Performing The Contract And/or Delivered To, Or Under The Legal Control Of The Government And Must Be Managed In Accordance With Federal Law. Electronic Records And Associated Metadata Must Be Accompanied By Sufficient Technical Documentation To Permit Understanding And Use Of The Records And Data.â
lajvamc And Its Contractors Are Responsible For Preventing The Alienation Or Unauthorized Destruction Of Records, Including All Forms Of Mutilation. Records May Not Be Removed From The Legal Custody Of Lajvamc Or Destroyed Except For In Accordance With The Provisions Of The Agency Records Schedules And With The Written Concurrence Of The Head Of The Contracting Activity. Willful And Unlawful Destruction, Damage Or Alienation Of Federal Records Is Subject To The Fines And Penalties Imposed By 18 U.s.c. 2701. In The Event Of  any Unlawful Or Accidental Removal, Defacing, Alteration, Or Destruction Of Records, Contractor Must Report To Lajvamc .the Agency Must Report Promptly To Nara In Accordance With 36 Cfr 1230.
the Contractor Shall Immediately Notify The Appropriate Contracting Officer Upon Discovery Of Any Inadvertent Or Unauthorized Disclosures Of Information, Data, Documentary Materials, Records Or Equipment. Disclosure Of Non-public Information Is Limited To Authorized Personnel With A Need-to-know As Described In The [contract Vehicle]. The Contractor Shall Ensure That The Appropriate Personnel, Administrative, Technical, And Physical Safeguards Are Established To Ensure The Security And Confidentiality Of This Information, Data, Documentary Material, Records And/or Equipment Is Properly Protected. The Contractor Shall Not Remove Material From Government Facilities Or Systems, Or Facilities Or Systems Operated Or Maintained On The Government S Behalf, Without The Express Written Permission Of The Head Of The Contracting Activity. When Information, Data, Documentary Material, Records And/or Equipment Is No Longer Required, It Shall Be Returned To Lajvamc Control Or The Contractor Must Hold It Until Otherwise Directed. Items Returned To The Government Shall Be Hand Carried, Mailed, Emailed, Or Securely Electronically Transmitted To The Contracting Officer Or Address Prescribed In The [contract Vehicle]. Destruction Of Records Is Expressly Prohibited Unless In Accordance With Paragraph (4).
the Contractor Is Required To Obtain The Contracting Officer's Approval Prior To Engaging In Any Contractual Relationship (sub-contractor) In Support Of This Contract Requiring The Disclosure Of Information, Documentary Material And/or Records Generated Under, Or Relating To, Contracts. The Contractor (and Any Sub-contractor) Is Required To Abide By Government And Lajvamc Guidance For Protecting Sensitive, Proprietary Information, Classified, And Controlled Unclassified Information.
the Contractor Shall Only Use Government It Equipment For Purposes Specifically Tied To Or Authorized By The Contract And In Accordance With Lajvamc Policy.â
the Contractor Shall Not Create Or Maintain Any Records Containing Any Non-public Lajvamc Information That Are Not Specifically Tied To Or Authorized By The Contract.â
the Contractor Shall Not Retain, Use, Sell, Or Disseminate Copies Of Any Deliverable That Contains Information Covered By The Privacy Act Of 1974 Or That Which Is Generally Protected From Public Disclosure By An Exemption To The Freedom Of Information Act.â
the Lajvamc Owns The Rights To All Data And Records Produced As Part Of This Contract. All Deliverables Under The Contract Are The Property Of The U.s. Government For Which Lajvamc Shall Have Unlimited Rights To Use, Dispose Of, Or Disclose Such Data Contained Therein As It Determines To Be In The Public Interest. Any Contractor Rights In The Data Or Deliverables Must Be Identified As Required By Far 52.227-11 Through Far 52.227-20.
training. Â all Contractor Employees Assigned To This Contract Who Create, Work With, Or Otherwise Handle Records Are Required To Take Lajvamc-provided Records Management Training. The Contractor Is Responsible For Confirming Training Has Been Completed According To Agency Policies, Including Initial Training And Any Annual Or Refresher Training.â
[note: To The Extent An Agency Requires Contractors To Complete Records Management Training, The Agency Must Provide The Training To The Contractor.]â
d. Â flow Down Of Requirements To Subcontractors
the Contractor Shall Incorporate The Substance Of This Clause, Its Terms And Requirements Including This Paragraph, In All Subcontracts Under This [contract Vehicle], And Require Written Subcontractor Acknowledgment Of Same.â
violation By A Subcontractor Of Any Provision Set Forth In This Clause Will Be Attributed To The Contractor.
â locations: louis A Johnson Va Medical Center 1 Medical Center Drive, Clarksburg, Wv 26301 braxton Co. Community Based Outreach Center (cboc) 93 Skidmore Lane, Sutton, Wv 26601 monongalia Co. Community Based Outreach Center (cboc) 40 Commerce Drive, Suite 101, Westover, Wv 26501 tucker Co. Community Based Outreach Center (cboc) 260 Spruce Street, Parsons, Wv 26287 monongaliaco. Veterans Outreach Center 34 Commerce Drive, Suite 101
westover, Wv 26501 wood Co. Community Based Outreach Center (cboc) 2311 Ohio Avenue, Suite A, Parkersburg Wv 26101 rosebud Facility 513 Rosebud Plaza, Clarksburg, Wv 26301
LUBELSKIE PRZEDSI BIORSTWO ENERGETYKI CIEPLNEJ S A Tender
Others
Poland
Closing Soon10 Jan 2025
Tender AmountRefer Documents
Details: Cenowement
184/Hari/20222222.
Prowadzone Zgonie Zgonie Z Zapisami Art. 7 Ust. 9 Acts of the 13th Day. In particular, W Zakresie Against the Chapter of the Agresji Na Ukraina O along with the National Security Protection Protection, Art. 7 Ust. 1–8 Stosuje Się Doępowanie Zamierzowanie Zadzielenie Zaj Orazów Competition Orazów Atościu Niżwotyre. - Public Zamówień Lub Z Wyłącze Stosowanie Tej Acty.
The subject of the order is: The Extensions of the 40 Szt.
See: Examination of the 40 Szt.
General Information:
The offer is held annually: 16.11.2022 R. To Godz.
Through the Zakupowy Htps:///malopolska-policja.eb2b.com.pl/////pl/////////.
"Uwaga! As a result, the Aby Oferty was included in the W Kwotach Brutto Brutto Brutto.
1.
Zamiot's request is: The Extension of the Services of 40 Szt.
"I ask you to say: 'I ask you for you.
These batteries were Towarem original, Fabryowo New Tj.
Ma Obowiązek Przekać Zamawiać Wu Polskim Karty Gwarancyjny Battery Oraz Zobowiązany jest Do Odebrania Zużytych Battery, Akumulatorów, Oraz Zobowiązany is Do Odebrania Zużytych Battery, Akumulatorów Battery, Oraz Zobowiązany is Do Odebrania Zuebrania Zużyty. Responding Ilościowo Wymdenonymy Battery, Celema Przekazania Ich Do Utylizacja According to the Przepisami.
As a result, the Wymian Battery belongs to the Protokół Odbioru, which includes the "Opiskonanych Czynności Z U relativelynienieniem Materianych Wwwach". 2. Termination: Realization.
- Octreśla Termin: 30 Dni Kalendarzowych od Daty Otrzymać 3. Realization: Realization.
: 30 Dninia.
- The opening of the Faktury: Prot is a protocol for the inclusion of the Cennegotiation.
- - - - . "Do 30 Dni Od Daty Otrzynia Prawidlovo Wystawionej Faktury Przelewem Na Wskazane przez Wykonawką Konto".
Kryterium Dokonania Wyboru Najkorzystnsze Oferty: Najniższa Cena Brutto.
Realization of Prac Możliwa Od Pon-. Pt. W Godz. 8:00 - 14:00 - 14:00 - 14:00 - 14:00 - 14:00 - 14:00 - 14:00 - 14:00 - 14:00 - - .
- The Asssault of the Law of Ressignation of Without Podanies.
"Open Officer Powinna Uwzglęć All Koszty M.in. Dojazd, Montażu, Utylization of Excavated Battery". 4. Lokalization Office: Lokalization.
The command of the Polish Police in Krakow.
31-571 Kraków, Ul. Mogilska 109.
Oświadcz Że consisted of Akcept's offer all the signatures of the Cenym. uwaga! As a member of the Sobie Wybory, Która will be Gwaranted the Exploration of the Principles of the Celowy, Oszczędny Z Zachowanie Prawy Uzyskiwani najachów. All the Prosecutions consisted of the Zakup Platform. In Razie Problems Ze Złożem Oferty Prosecute to Się Ziem Helpdesk Eb2b - Kontakt W Stopcey Internetowej.
Department Of Energy Tender
Others...+2Software and IT Solutions, Electrical and Electronics
United States
Closing Date1 Jul 2025
Tender AmountRefer Documents
Details: Realtime Electrochemical Waveform Control With Integrated Performance Monitoring integrates Active Waveform Analysis For Live Performance Monitoring And Optimization In Electrochemical Devices. the Challenge: the Electrolysis And Fuel Cell Industries Are Poised At A Revolutionary Juncture, Driven By The Rapid Advancements In Power Electronics. Traditional Approaches To Performance Analytics In These Sectors Involve Pausing System Operations, A Method That Becomes Less Feasible As Demands For Efficiency And System Uptime Increase. Historically, Sophisticated Waveform Applications Necessary For Detailed Analytics Were Unattainable In Large Systems, Limiting Operational Insights And Optimization Opportunities. The Integration Of Realtime Electrochemical Waveform Control With Performance Monitoring Realtime Waveform Analysis Introduces A Dynamic Shift, Enabling Continuous System Health Monitoring And Live Optimization Without Halting Operations. how It Works: this Technology Offers A Breakthrough In The Operation Of Electrochemical Devices Such As Batteries, Fuel Cells, And Electrolysis Systems. By Integrating Real-time Waveform Analysis Tools Into The Power Waveforms Applied To These Devices, It Enables Continuous Performance Analytics And Optimization Without Interrupting Normal Operations. This Approach Allows For The Application Of Complex Waveforms Like Pulse Width Modulation To Modulate Power More Effectively, Enhancing Device Performance And Efficiency. key Advantages: enables Live Performance Monitoring And Optimization Of Electrochemical Devices. allows For The Application Of Complex Waveforms Without Halting Device Operation. improves Precision In Performance Analytics For Large-scale Systems. facilitates High-resolution Data Collection For Health Assessment Of Devices. potentially Reduces Capital Costs Through Decreased Equipment Replacement Needs. increases System Efficiency, Lowering The Cost Of Produced Goods. problems Solved real-time System Monitoring: Eliminates The Need To Halt Device Operation For Performance Measurements. overcomes Limitations Of Precision Analytics In Large-scale Electrochemical Systems. addresses The Lack Of Sophisticated Power Electronics In Large Electrolysis Systems. solves The Challenge Of Collecting High-quality Information From Large Systems. market Applications large-scale Electrolysis Plants And Fuel Cell Operators: Provides Crucial Insights Into System Health, Enabling Proactive Maintenance And Efficiency Optimization. industrial Scale Green Energy Production: Supports The Growth Of Environmentally Sustainable Energy Production By Enhancing The Performance And Reliability Of Systems Involved In Hydrogen Production. research And Development Facilities: Offers A Rich Data Environment To Test New Materials And Theories At Both Micro And Macro Levels, Accelerating Innovation. development Status: Trl 3 us Provisional Patent Application No. 63/624,227, “electrochemical Cell Systems And Associated Power Systems, Components, And Methods,” Bea Docket No. Ba-1394 inl Tech Partnerships: Your Gateway To Innovation inl Offers Strategic Access To Proprietary Technology, Enhancing Small Business Growth And Contributing To Economic And Public Advancement. We Cater Licensing Terms To Each Business We Work With, Ensuring Mutually Beneficial Agreements. Engage With Our Diverse Technology Offerings To Propel Your Company Forward. learn More About Our Licensing Opportunities And The Support We Provide At Https://inl.gov/technology-deployment/. For Specific Discussions On How Your Business Can Benefit, Please Contact Td@inl.gov. inl’s Technology Deployment Department Focuses Exclusively On Licensing Intellectual Property And Partnering With Industry Collaborators Capable Of Commercializing Our Innovations. Our Goal Is To Commercialize The Technologies Developed By Inl Researchers. We Do Not Engage In Purchasing, Manufacturing, Procurement Decisions, Or Providing Funding. Additionally, This Is Not A Call For External Services For The Development Of This Technology.
2691-2700 of 2751 active Tenders