Adela Serra Ty Memorial Medical Center Tender
Adela Serra Ty Memorial Medical Center Tender
Costs
Summary
Procurement Of Various Equipment For Physical And Rehabilitation Ib No. 2024-07-16 (35) , Medical And Dental Equipment ,adela Serra Ty Memorial Medical Center
Description
Description Procurement Of Various Equipment For Physical And Rehabilitation Ib No. 2024-07-16 (35) 1. The Adela Serra Ty Memorial Medical Center, Through The Astmmc Fund Intends To Apply The Sum Of Fourteen Million Nine Hundred Fifty Thousand Pesos Only [php 14,950,000.00] Being The Abc To Payments Under The Contract For An Item. Bids Received In Excess Of The Abc For Each Lot Shall Be Automatically Rejected At Bid Opening. 2. The Adela Serra Ty Memorial Medical Center Now Invites Bids For The Above Procurement Project. Delivery Of The Goods Is Required By 60 Calendar Days. Bidders Should Have Completed, Within 5 Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii (instructions To Bidders). 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra No. 5183. 4. Prospective Bidders May Obtain Further Information From Adela Serra Ty Memorial Medical Center And Inspect The Bidding Documents At The Address Given Below During 8:00am To 5:00pm, Monday Thru Friday. 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On June 25, 2024 To July 16, 2024 From The Given Address Below And Upon Payment Of The Applicable Fee For The Bidding Documents In The Amount Of Twenty Five Thousand Pesos Only [php 25,000.00]. The Procuring Entity Shall Allow The Bidder To Present Its Proof Of Payment For The Fees In The Manner Whether It Will Be Presented In Person, By Facsimile, Or Through Electronic Means. 6. The Adela Serra Ty Memorial Medical Center Will Hold A Pre-bid Conference On July 04, 2024; 09:00 Am At Bac Conference Room, Opd Bldg, Astmmc, Tandag City And Or Through Video Conferencing Or Webcasting Via Meet.google.com/rbu-snjw-vga Which Shall Be Open To Prospective Bidders. 7. Bids Must Be Duly Received By The Bac Secretariat Through Manual Submission At The Office Address Indicated Below, On Or Before 09:00 Am; July 16, 2024. Late Bids Shall Not Be Accepted. 8. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 14. 9. Bid Opening Shall Be On 09:01 Am; July 16, 2024 At Bac Conference Room, Opd Bldg, Astmmc, Tandag City And Or Through Video Conferencing Or Webcasting Via Meet.google.com/rbu-snjw-vga Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend The Activity. 10. The Adela Serra Ty Memorial Medical Center Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections 35.6 And 41 Of The 2016 Revised Irr Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 11. For Further Information, Please Refer To: Dominador B. Toral, Md Bac Office, 2nd Floor Opd Bldg. Astmmc, Tandag City, Sds, 8300 Tel No. 086-211-4306 Astmmcprocurement@gmail.com 12. For Downloading Of Bidding Documents, You May Visit: Philgeps.gov.ph Dominador B. Toral, Rn, Md, Dpbohns Hbac Chairman Lot No. Description Unit Qty Total Delivered, Weeks/months 1 Color Doppler Muskuloskeletal Ultrasound Machine Unit 1 5,000,000.00 60 Calendar Days Technical Specifications * Color Monitor, Tft Or Lcd From At Least "21.5-inch High Resolution Led Monitor * Max Of 360° Articulating Monitor Arm * At Least 10.1-13.3 Inch, Ultra-slim, Angle Adjustable, Touch Gestures Supporter * Dynamic Range At Least 180 Db. * Frequency Range : 1-18 Mhz Imaging Modes *2d-mode *power Doppler (pd) Mode *m-mode * Scan Mode *color M-mode *3d/4d/xi Stic Imaging Mode *anatomical Mode *freehand 3d Mode *color Doppler Mode *dual Mode *pulsed Wave (pw) Spectral Doppler Mode *quad Mode *continuous Wave (cw) Doppler Mode *combined Mode *tissue Doppler Imaging (tdi) Mode *simultaneous Mode *tissue Doppler Wave (tdw) Mode *zoom Mode *s-flow Mode * Digital And Caliper Measurement Functions Required For Both Distance, Area And Volume. * Trackball And/or Touchpad In User Panel. * Frame By Frame Image Memory Or Cine-loop. 2000 Fps (hz) * Doppler Display To Indicate Blood Flow Both Numerically And In Colour. * Connection Port For Image Printing To Be Included (printer Specified Separately). * Hd/cd/dvd/usb Storage Unit * Internal Hard Disk Of At Least 500gb -1 Tb * Innovative Dual-wing Floating Arm * Raw Data * Patient Information Management * At Least 4 Probes Ports * Storage Space * Gel Warmer * Cable Management * Side Tray Connectivity - Built-in Wireless Adapter & Lan : 802.11n, Dual Band 2.4ghz & 5ghz - Built-in Battery Up To~60 Min Scanning Application Physical Specification Musculoskeletal Audio Speakers Nerve Stereo Audio Speakers Small Parts Monitor With Unique Dual-wing Floating Arm Vascular Rotate Angle:360 Degrees To The Left And 360 Degrees To The Right Pediatrics Along With The Support Arm Emergency Medicine Up: 150mm Others Front/back: 300mm Wheels Front Castor (2 Ea): Total Lock And Break Rear Castor (2 Ea): Right One For Electrical Power Total Lock And Break; Left One For Swivel Lock Voltage: 220-240v~ Frequency: 50/60 Hz Transducer Port And Holder Power Consumption: Max. 800va Transducer Ports With Dust Circuit Breaker: 100v~, 10a Prevention: 4 Active Ports, 1 More For Pencil Probe Only Operating Environment Transducer Holder: 5 (one For Ambient Temperature: 0-40 °c Pencil Transducer), Plus 1 Relative Humidity: 30%-85% (no Condensation) Dedicated Endocavity Transducer Holder Atmospheric Pressure: Adjustable Panel Height 700hpa-1060hpa Touch Screen Display User Interface * At Least 21.5 -inch High Sensitivity Floating Control Panel Anti-glare Color Touch Screen Resolution: Up To 1280*800 Brightness Adjustable For The Digital Brightness And Contrast Adjustment Through Preset Backlight Of The Whole Control Panel Angel Adjustable Range: 360degrees Full-sized, Backlit Qwerty Keyboard Viewing Angle: ≥178 Degrees 8 Programmable Keys Support Touch Screen Gestures 8-segment Tgc Control Support Either Hand Writing Or With Gloves On Rotate Angle Range: At Least 180 Degrees 10.1” Touch Panel High Resolution Led Monitor Touch Gestures Down/up: 200±20 Mm Or Better Swipe Down/up: Display/remove 3.2 Monitor Up Projected Image On Touch Screen * At Least 21.5-inch High Resolution Color Up Swipe Horizontally: Page Up/down Led Monitor Or Review Images/cine Loops One By One Resolution: 1920x1080 At Least True Color Swipe From Left Edge To Right: Viewing Angle: ≥178 Degrees Display Hidden Menu On Projected Image. Digital Brightness And Contrast Image Parameter Adjustment. Adjustment Through Preset Measurement On Projected Image On Touch Screen Tile/rotate Independent Zoom In/ Out The Projected Image On Touch Screen Adjustment: Rotate Or Erase On Projected 3d/4d Image On Touch Screen Tilt Angle Range:110 Degrees 8 User Defined Gestures Using Two Rotate Angle Range: 180 Degrees Fingers For More Functions, Such Recorder As Freeze, Save, Print, Activate Printer Specific Imaging Modes, Included Probes: Measurements, And Some Other A) Convex With At Least Triple Frequency, Bandwidth Of At Least 2mhz- 8mhz Frequency; Special Functions. B) Linear With At Least Triple Frequency, Bandwidth Of At Least 3 Mhz-16 Frequency; Touch Screen Menu Layout Editable C) Phased Array With At Least Triple Frequency, Bandwidth Of At Least 2 Mhz Including 3 Mhz Frequency; (optional) System Boot-up Boot-up From Shut-down: < 90sec Trolley To Include Shelf Space For Image Printer And Documentation Application: - Shared Service (includes Musculoskeletal, Nerve Obstetrics, Vascular, Small Parts, Pediatrics, Emergency Medicine, Gynecology, Abdomen, Urology, And Cardiology Packages). - Dicom Basic - Dicom/hl7 Worklist - 3d/4d Includes: - Viewing Workstation - 1 Unit 55" Smart Tv For Viewing Of Patient Computer Specifications * 1 Unit Branded Computer System At Least 16cores Up Processor 3.5ghz Up With 32gb Of Ram And Dedicated Video Card At Least 8gb Gddr5 24 Inches Monitor With Wireless Adapter, Ups, Mouse, Keyboard, Speaker And Other Accessories Needed * Provide Wireless & Wired Access Point For Pacsplus & Dicom (router & Switch Hub) * 2 Units Branded Laptop At Least 17" And Up With Viewing System For Ultrasound Synchronizing To Ultrasound '-16 Core, 1 Tb With Bag & Wireless Mouse * 2 Units Rotating Chair Adjustable Up & Down * 1 Unit Modern Table Hard Structure Steel And Chrome Plated Or Stainless * 2kva Ups With Avr Computer Grade For Workstation - 3kva Ups Medical Grade With Trolly For Ultrasound Consumables - 2000 Pcs Ultrasound Printer Thermal Paper - 1000 Btls Ultrasound Gel Requirements For Commissioning *** Supplier To Perform Installation, Safety And Operation Checks Before Handover *** Staff/end-user And Biomed Technician In Coordination With The Engineering Department To Affirm Completion Of Installation Training End Users & Biomedical/engineer Training Of Users And Biomedical *** Training Of Users In Operation And Basic Maintenance And Calibration Shall Be Provided *** Supplier To Issue Certificate Of Training *** Comprehensive Training Of Users In Operation , Basic And Advance Maintenance Shall Be Provided *** Off-site Comprehensive Training 4-6 Biomed Technician Participants Can Attend For One Week Technical Training & Orientation Of Biomedical Technician/engineer In Including Fares, Accommodation And Meals Off-site Comprehensive Training 1 End-user Participants Can Attend For One Week Technical Training & Orientation Of Biomedical Technician/engineer In Including Fares, Accommodation And Meals User Care*** Unit Layout To Enable Easy Cleaning And Sterilization Of All Surfaces. Warranty And Maintenance Warranty 3 Years Warranty Should Be Provided By The Supplier Parts = At Least 5 Years Maintenance And Service = At Least 2 Years Maintenance Tasks *semi-annual Preventive Maintenance/calibration To Be Conducted By The Company Engineer In-charge *advanced Maintenance Tasks Required Shall Be Documented *physical And Rehabilitation Medicine As The Need Arise Type Of Service Contract Service Contract Is Recommended In Case No In-house Service Experience Is Available To Ensure That Preventive Maintenance Will Be Performed At Regular Intervals. Pricing For Service Contracts Should Be Negotiated Before The System Is Purchased. Spare Parts Availability Post-warranty 10 Years Software / Hardware Upgrade Availability Routine Software Updates Should Be Provided Documentation: Documentation Requirements - User, Technical And Maintenance Manuals To Be Supplied In English Language - At Least 3 Copies - Certificate Of Calibration And Inspection To Be Provided - List Of Equipment And Procedures Required For Local Calibration And Routine Maintenance To Be Provided By The Supplier - List Of Important Spare Parts And Accessories, With Their Part Numbers And Cost To Be Provided By The Supplier - Trade-in With Manufacturer If Available Decommissioning Estimated Life Span: 10 Years Safety And Standards Risk Classification Regulatory Approval / Certification Should Be A Ce Or Ul Approved Product. "manufacturer / Supplier Should Have Iso Certificate For Quality Standard. Electrical Safety Conforms To Standards 2 Tecar Therapy With Two Independent Channels Unit 1 4,000,000.00 60 Calendar Days Purpose Of Use: Tecar Therapy Is A Form Of Endogenous Thermotherapy (it Heals Your Body By Creating Heat Inside It) Based On Radio Waves. It Is Also Known As “capacitive And Resistive Electrical Transfer”. Other Types Of Laser Therapy Include Tens And Pemf, Which Use Different Wavelengths. Technical Specification Connected Device By Wifi (software Updated And Remote Technical Assistance) Operating Frequency: Tecar (300-500-1000khz), High Ems (1.5-4khz) , High Tens (2-5-25hz) Weight: At Least 6 Kg - Trolley : 17 Kg Manufactured To Iso13485 - Standards. Certifications: Medical Device - Fda-cleared Features: Capacitive Mode Medium-direct Current Boost Soft-500khz Deep Cet-300khz Dynamic-alternate Function Soft And Deep Resistive Mode Boost-medum-low Neutral Fix-neutral Mobile Two (2) Resistive Probes Can Use At The Same Time With Neutral Return Plate Resistive And Capacitive Can Use At The Same Time Resistive With Tens Mode (2, 5 And 25 Hz) Static-dynamic Neutral Fix- Neutral Mobile Resistive With Ems Mode : Focal-dynamic-radial Neutral Fix-neutral Mobile Mix Mode : Boost-medium-low Accessories: Resistive And Capacitive Tecar Handpiece Resistive And Capacitive Extension Cable 1 Neutral Extension Cable 1 Mobile Neutral Cable 1 Metal Neutral Plate 1 Mobile Neutral Handheld Neutral Adhesive Cable 2 Ret Tecar Bracelets 3 Capacitive Electrodes ( Small, Medium, Large) 1 Capacitive Convex Electrode 3 Resistive Electrodes ( Small, Medium, Large) 1 Resistive Convex Electrode 2 Multipolar Electrodes (small And Large) Resistive Focus Electrode 1 Resistive Fixed Pad Conducting Cream (oil Based) 1 Power Cord Power Supply: Ac 220vac ± 10% 50/60hz Dedicated Trolley With Wheels Other Components Per Unit 1 Unit Avr 3kva & 1 Unit Ups 3kva 1unit Dehumifier 15 Liters 1 Unit 5 Meters Extension Wire Standard Provide Adaptor If Needed Per Unit Warranty And Maintenance Warranty 3 Years Warranty Should Be Provided By The Supplier Parts = At Least 3 Years Maintenance And Service = At Least 3 Years Maintenance Tasks *semi-annual Preventive Maintenance/calibration To Be Conducted By The Company Engineer In-charge *advanced Maintenance Tasks Required Shall Be Documented *end User As The Need Arise Type Of Service Contract Service Contract Is Recommended In Case No In-house Service Experience Is Available To Ensure That Preventive Maintenance Will Be Performed At Regular Intervals. Pricing For Service Contracts Should Be Negotiated Before The System Is Purchased. Spare Parts Availability Post-warranty 10 Years Software / Hardware Upgrade Availability Routine Software Updates Should Be Provided Sterilization Process For Accessories : Chemical Sterilization- Non Corrosive Chemical / Disinfectant Consumables / Reagents Requirements For Commissioning *** Supplier To Perform Installation, Safety And Operation Checks Before Handover *** Laboratory Staff/end-user And Biomed Technician In Coordination With The Engineering Department To Affirm Completion Of Installation Safety And Standards Risk Classification Regulatory Approval / Certification Should Be A Ce Or Ul Approved Product. "manufacturer / Supplier Should Have Iso Certificate For Quality Standard. Electrical Safety Conforms To Standards 3 Partial Weight Bearing (body Weight Support) Unit 1 980,000.00 60 Calendar Days Purpose Of Use: Pwb Is A Broad Term And Can Range From Anything Greater Than Non-weight Bearing To Anything Less Than Full Weight Bearing. This Status Should Be Accompanied By A Percentage Figure To Further Describe The Extent Of Weight Bearing. Most Sources Define Partial Weight Bearing As Being 30% To 50% Of A Patient's Body Weight. Features And Benefits Assist Posture, Balance & Weight Bearing Prevent Excessive Rotation Facilitate Hip Flexor Tension Differential Control Of Right Vs. Left Side Walk On Treadmill Or Over Ground Mobile Design Goes From Room To Room Train Gait Under Fall-free Conditions Frees Therapist To Facilitate Walking Wide Range Of Patient Sizes & Impairments Lift Patients Of All Sizes From Sit To Stand Fall-free, Supported Walking Technical Specifications - Hand Remote Control: Up/down Function - Minimum User Weight: At Least 308lbs(140kg) - Maximum User Weight: At Least 500lbs(227kg) - Maximum Unit Height: At Least 7’10” - Maximum Patient Height On Ground: At Least 7’4” - Lift Stroke: At Least 20” - Inside Base Width: At Least 34” (86.4cm) - Width: At Least 94cm - With Caster Wheels - Input Power: 220vac, 60hz - Battery Capacity: Rechargeable Battery 24vdc Power Supply: Ac 220vac ± 10% 50/60hz Accessories: Harness ( Complete Set) Warranty And Maintenance Warranty 3 Years Warranty Should Be Provided By The Supplier Parts = At Least 3 Years Maintenance And Service = At Least 3 Years Maintenance Tasks *semi-annual Preventive Maintenance/calibration To Be Conducted By The Company Engineer In-charge *advanced Maintenance Tasks Required Shall Be Documented *end User As The Need Arise Type Of Service Contract Service Contract Is Recommended In Case No In-house Service Experience Is Available To Ensure That Preventive Maintenance Will Be Performed At Regular Intervals. Pricing For Service Contracts Should Be Negotiated Before The System Is Purchased. Spare Parts Availability Post-warranty 10 Years Software / Hardware Upgrade Availability Routine Software Updates Should Be Provided Sterilization Process For Accessories : Chemical Sterilization- Non Corrosive Chemical / Disinfectant Consumables / Reagents Requirements For Commissioning *** Supplier To Perform Installation, Safety And Operation Checks Before Handover *** Laboratory Staff/end-user And Biomed Technician In Coordination With The Engineering Department To Affirm Completion Of Installation Safety And Standards Risk Classification Regulatory Approval / Certification Should Be A Ce Or Ul Approved Product. "manufacturer / Supplier Should Have Iso Certificate For Quality Standard. Electrical Safety Conforms To Standards 4 Electrotherapy And Semg Biofeedback System Unit 1 550,000.00 60 Calendar Days Purpose Of Use: Patients With The Treatment They Deserve And Therapists With The Support They Need. Research Shows That The Use Of Neuromuscular Electrical Stimulation (nmes) Relieves Patients Of The Emotional, Physical, And Financial Burdens Of Feeding Tubes—allowing A Return To Normalcy. It Also Creates An Opportunity For Therapists To Not Only Manage Their Patients’ Difficulties, But Also To Overcome Them. Physical Characteristic W= Suppliers Preference D = Suppliers Preference H = Suppliers Preference Weight : At Least 0.34 Kg Input 6v (4x1.5v Aa) Maximum Voltage (patient) 70v (+0/-5v) Mode Continuous Product Characteristics Temperature 5º To 40º C Relative Humidity 15% To 95% Atmospheric Pressure 700hpa To 1060hpa Transport And Storage Conditions Temperature -25ºc To 70ºc Relative Humidity Max 90% Atmospheric Pressure 700hpa To 1060hpa At Least 4-channel Nmes Symmetrical Biphasic Intensity 0-25 Ma (constant Current) Channel Mode Continuous, Reciprocal, Co-contract Phase Duration 60-300 Μsec (10 % Accuracy) Frequency 1-80 Pps (5 % Accuracy) Treatment Time 1-240 Min Interphase Interval 100 Μsec Intensity 0-25 Ma (constant Current) Channel Mode Co-contract Phase Duration 300 Μsec (10 % Accuracy) Frequency 80 Pps (5 % Accuracy) Treatment Time 60 Min Interphase Interval 100 Μsec 2-channel Emg Semg Semg Range 0.2 To 2000 Μv Rms (continuous) Sensitivity 0.1 Μv Rms Accuracy 6% Of Μv Reading +/- 0.3 Μv Standard Accessories: - 1 Travel Case - 1 Kit Of 4 Snap Wires For Electrodes - 1 Emg Reference Wire - 1 Pack Of 4 Adult Electrodes - 1 Stand - 1 Stylus For Touch Screen - 1 Rubber Protection Sleeve - 4 Aa 1.5v Batteries - 1 Micro Sd Card - 1 User Manual And Pc Share Application On Usb Key - 1 Printed Quick Start Guide - Extra 2 Pieces Electrode Pads Includes : All-in-one Pc - Intel Core Processor - 1tb Internal Storage - 8gb Ram Memory - Win Other Components Per Unit 1 Unit Ups With Avr At Least 3000va Up 1 Unit 5 Meters Extension Wire Standard Provide Adaptor If Needed Per Unit Warranty And Maintenance Warranty 3 Years Warranty Should Be Provided By The Supplier Parts = At Least 3 Years Maintenance And Service = At Least 3 Years Maintenance Tasks *semi-annual Preventive Maintenance/calibration To Be Conducted By The Company Engineer In-charge *advanced Maintenance Tasks Required Shall Be Documented *end User As The Need Arise Type Of Service Contract Service Contract Is Recommended In Case No In-house Service Experience Is Available To Ensure That Preventive Maintenance Will Be Performed At Regular Intervals. Pricing For Service Contracts Should Be Negotiated Before The System Is Purchased. Spare Parts Availability Post-warranty 10 Years Software / Hardware Upgrade Availability Routine Software Updates Should Be Provided Sterilization Process For Accessories: Chemical Sterilization- Non-corrosive Chemical / Disinfectant Consumables/reagents Requirements For Commissioning *** Supplier To Perform Installation, Safety, And Operation Checks Before Handover *** Staff/end-user And Biomed Technician In Coordination With The Engineering Department To Affirm Completion Of Installation Safety And Standards Risk Classification Regulatory Approval / Certification Should Be A Ce Or Ul Approved Product. "manufacturer/supplier Should Have Iso Certificate For Quality Standard. Electrical Safety Conforms To Standards 5 Electromagnetic Field Technology Machine Unit 1 4,100,000.00 60 Calendar Days Purpose Of Use: Features And Benefits I. Technology: High Intensity Electromagnetic Field Ii. Highest Maximum Stimulation Intensity Of Up To 2.5 Tesla Iii. Frequency Range Of 1-150hz Iv. Standard Accessories A. Focus Field Applicator With 6 Joint Arm Movement B. Applicator Arm With Cable Holder C. Arm Installation Set D. User’s Manual E. Power Cord F. Main Fuses V. Magnetic Field Classification: Class Iia According To Mdd 93/42/eec Vi. Main Unit Display A. Graphic Color Touch Screen At Least 8.4“ B. Preset Protocols With User Defined Protocols C. Body Parts Screen Navigation D. Quick Preset Protocols E. Manual Setting Of Therapy Parameters 1. Basic Mode 2. Sequence Mode 3. Single Mode Vii. Therapy Parameters A. Pulse Type: Sine, Biphasic B. Intensity Range: .7 To 2.5 T C. Intensity Setting: Relative 0-100% D. Intensity Modulation Type: None, Trapezoid, Sine, Staircase E. Pulse Repetition Rate Modulation Types: None, Alternating, Trapezoid, Sine, Random Viii. Device Design A. Unit Weight Is At Least 46kg Including Package And Standard Accessories App (included) B. Unit Dimensions (wxhxd) At Least 20x28x23 Inches C. Pulse Quality Monitor 400 Watts D. Intensity Predictor: Ability To Deliver 100% Intensity With Increasing Frequency E. Patented Cool Flow Technology Technical Specification Frequency Up To 150 Hz Display At Least 8.4’’ Color Touchscreen Quick Protocols Yes Body Part Navigation Yes Preset Protocols Yes Therapeutic Encyclopedia Yes Patient Database Yes Intensity Up To 2.5 T Dimension 500 X 970 X 580 Mm Suppliers Preference Weight At Least 33 Kg Main Supply 100-240 V Ac, 50-60 Hz Arm Six-joint Arm Applicator Focused Field Applicator Pulse Quality Monitor Yes Power Supply: Ac 220vac ± 10% 50/60hz Dedicated Trolley With Wheels Other Components Per Unit Other Components Per Unit 1 Unit Avr 3kva & 1 Unit Ups 3kva 1 Unit 5 Meters Extension Wire Standard Provide Adaptor If Needed Per Unit Warranty And Maintenance Warranty 3 Years Warranty Should Be Provided By The Supplier Parts = At Least 3 Years Maintenance And Service = At Least 3 Years Maintenance Tasks *semi-annual Preventive Maintenance/calibration To Be Conducted By The Company Engineer In-charge *advanced Maintenance Tasks Required Shall Be Documented *end User As The Need Arises Type Of Service Contract Service Contract Is Recommended In Case No In-house Service Experience Is Available To Ensure That Preventive Maintenance Will Be Performed At Regular Intervals. Pricing For Service Contracts Should Be Negotiated Before The System Is Purchased. Spare Parts Availability Post-warranty 10 Years Software / Hardware Upgrade Availability Routine Software Updates Should Be Provided Sterilization Process For Accessories : Chemical Sterilization- Non Corrosive Chemical / Disinfectant Consumables / Reagents Requirements For Commissioning *** Supplier To Perform Installation, Safety And Operation Checks Before Handover *** Staff/end-user And Biomed Technician In Coordination With The Engineering Department To Affirm Completion Of Installation Safety And Standards Risk Classification Regulatory Approval / Certification Should Be A Ce Or Ul Approved Product. "manufacturer / Supplier Should Have Iso Certificate For Quality Standard. Electrical Safety Conforms To Standards 6 Smart Balance Board Unit 1 320,000.00 60 Calendar Days Purpose Of Use: Features And Benefits Premium Wooden Smart Balance Board At Least (19.6" X 13.7") Ios/android App With Predefined Training Programs & At Least 14 Balance Games Multiple Patients Dashboard Wearable Bluetooth Motion Sensor With 3 Velcro Straps Rom Assessment And Training Cycling Speedometer Trainer Holds Up To 450 Lbs *mobile Device & Balance Cushion Are Not Included Technical Specification Wireless Connectivity To Your Smartphone Or Tablet Battery Life Is 400 Hours Of Continuous Use Led & Audio Indicators 3-axis Accelerometer Sensors Operating Temperature: -5 ˚c To 45 ˚c (23 ˚f To 113 ˚f) Battery Type: 2032 Lithium Coin Battery 3v Communication Modules: Bluetooth Low Energy (ble) Power Supply: Ac 220vac ± 10% 50/60hz Inclusions: Tripod Tablet Sensor With Board Strap Inflatable Base 43' Smart Television Other Components Per Unit 1 Unit Avr 3kva & 1 Unit Ups 3kva 1 Unit 5 Meters Extension Wire Standard Provide Adaptor If Needed Per Unit Warranty And Maintenance Warranty 3 Years Warranty Should Be Provided By The Supplier Parts = At Least 3 Years Maintenance And Service = At Least 3 Years Maintenance Tasks *semi-annual Preventive Maintenance/calibration To Be Conducted By The Company Engineer In-charge *advanced Maintenance Tasks Required Shall Be Documented *end User As The Need Arises Type Of Service Contract Service Contract Is Recommended In Case No In-house Service Experience Is Available To Ensure That Preventive Maintenance Will Be Performed At Regular Intervals. Pricing For Service Contracts Should Be Negotiated Before The System Is Purchased. Spare Parts Availability Post-warranty 10 Years Software / Hardware Upgrade Availability Routine Software Updates Should Be Provided Sterilization Process For Accessories : Chemical Sterilization- Non Corrosive Chemical / Disinfectant Consumables/reagents Requirements For Commissioning *** Supplier To Perform Installation, Safety, And Operation Checks Before Handover *** Staff/end-user And Biomed Technician In Coordination With The Engineering Department To Affirm Completion Of Installation Safety And Standards Risk Classification Regulatory Approval / Certification Should Be A Ce Or Ul Approved Product. "manufacturer / Supplier Should Have Iso Certificate For Quality Standard. Electrical Safety Conforms To Standards
Contact
Tender Id
1cae152f-40a9-34bb-a9ec-4e1676bf2e14Tender No
10985852Tender Authority
Adela Serra Ty Memorial Medical Center ViewPurchaser Address
-Website
http://notices.ps-philgeps.gov.ph