Fabrication Tenders
Fabrication Tenders
Indian Army Tender
Goods
Machinery and Tools
GEM
Corrigendum : Corrigendum Added
Kupwara, Jammu & Kashmir
Description: CATEGORY: HDPE laminated Sand Bag of size 75x40 cm Sand colour and
each bag having weight not less than 60 gms , SHS 6 mm
thick size 120x120mm x 2.4m long for column with holes as
per tech spec , ISMB 150 RSJ 150 x 75 mm 1.85 mtr long for
beam conforming to relevant IS as per tech spec att , ISMB
150 RSJ 150 x 75 mm 60 Cm mtr long for beam conforming
to relevant IS as per tech spec att , ISMB 125 RSJ 125 x
70mm 3.0m long for beam conforming to relevant IS as per
tech spec att , SHS 6 mm thick size 70x70mm x 1.85m long
for with conforming to IS as per tech spec att , 6mm thick
MS plate 75x150mm welded with G1 beam connected with
nut and bolts , 6mm thick MS plate 100mm x 100mm with a
gap of 75mm as per tech spec att , 12mm dia nut bolt
75mm long inserted in 12mm dia eight nos hole in each
column , 6mm thick MS base plate of size 150 x150 mm for
SHS column as per tech spec att , Steel Roofing Trough of
size 1630 mm x 613 mm x 180 mm made out of 2 mm thick
as per tech spec att , MS hexagonal nuts Bolts and washers
12 mm dia 40 mm long. , LDPE sheet 3 m wide weighing
1.00 Kg per RM black in colour and shall contain as per tech
spec att , Red Oxide primer conforming to relevant IS ,
Synthetic Enamel Paint Colour Green Ist quality conforming
to relevant IS as per tech spec att , Thinner as per as per
tech spec att . Sample to be approved before supply. , Dry
distemper as per tech spec att. Sample to be approved
before supply , Chalk whiting as per tech spec attSample to
be approved before supply , Paint Brush 4 inch Make Amar
or Lucky Sample to be approved before supply , Pre
fabricated steel door of size 0.90m x 1.80m made out of
2mm thick MS black carbon sheet as per tech spec att ,
Supply of Swivel Bullet proof glass glass 750mm x500mm
size 72 mm thick as per tech spec att , Silicone Gel sealent
of 01 pack of 400 gms including aplicator gun , Ply wood 10
mm thick as per requirement for flat surface , Foundation
bolts of 16 mm dia and 250 m long with nut bolts washer
etc. , Stone Aggregate to be crushed rock or gravel 20mm
graded confirming to relevant IS , Natural sand confirming
to relevant IS as per tech spec att , Stone Aggregate to be
crushed rock or gravel 40mm graded confirming to relevant
IS as per tech spec att , Rapidite quick setting liquid. ,
Integrated water proofing compound. , Drilling machine
portable type, electrically driven , Aluminimum straight
edge 50mm squre 2mm thick 1800mm long , wooden Flat
Gurmala , Water leveling pipe PVC 100 mtr , Hand Rivet
Gun machine , Drill bit 6mm dia , Drill bit 8mm dia , Drill bit
10mm dia , Tape measuring metallic 30 M , Mason trowel
Karchi , Tasla Iron 18 inch , Shovel with wooden handle ,
Axe Picks with wooden handle , Fawda with wooden handle
, Crobar 5 feet long , Rammer with wooden handle of WT 5
AND 10 KG , Sieve for sieving fine and crose AGG 900 x
1500mm made of angle iron frame with stand , Brick
Hammer 1,2 Kgs , Cutting plier Insulate 6 inch , Screw
Driver 12 INCH with insulated plastic , Digital Clamp Meter ,
Pipe Wrench 12 inch , Pipe Wrench 18 inch , Adjustable
spanner 12 inch , Hacksaw frame with 2 Blade , Hand
Gloves Canvas with ISI Mark , Aluminium Sprit level 6 inch ,
Brick Line , Plumbob
Closing Date11 Jan 2025
Tender Amount₹ 1.7 Cr
South Central Railway - SCR Tender
Auction
Scraps
Ireps
Corrigendum : Closing Date Modified
Hyderabad, Telangana
Description: 12274ms24j, 98050175, Quantity- 85.660 Mts Scrap Condemned Unserviceable Ms-gi-ci Rusted,corroded,dusted Mixed Scrap Of C And W,loco,p. Way,signal Interlocking Material Consisting Of All Type Of Sheets,boxes,ms High Gauge,pipes,footsteps,rings,strips,filters,trusses,patch Cut Parts,gutters,drum Clocks,distribution Boards,u Rack,boring Rod,ms Panel Body,ms Battery Charger Covers,hand Cuffs,driver Seat,hand Cart,push Trolley,packing Strips,ms Body Of Block Instrument,ms Boiler Coil Cut Pieces,42 U Rack Ms Body,ms Collapsible Gate,ms Termination Box,ms Bathroom Ventilator,ms Body Of Data Logger,ms Heater Coil,screen Guard,nuts,bolts,lavatory Doors,ms Carriage Doors,pins,rivets,links,rods,angle Cut Pieces,structural Frames,brackets,drums,cocks,basins,wire Meshes,wire Ropes,water Tank Cut Up Parts,casings,corrugated Sheets,filter Top And Bottom Caps,clamps,washer Plates,stands,frames,sheet Cuts,plate Cuts,joists,channels,bases,plates,flats Cut Pieces,vestibule Frames,window,door,shutters,head Stocks Cut Up Parts,broken T And P Items,racks,compensating Rings,bindings,washers,dust Bins,chains,berth Strips,gate Frames,iron Furniture,motor Bodies,screw Rods,levers,flats,rod Cut Pieces,trolley Wheels,gi Ducts,glow Sign Boards,ms Electrical Scrap,building Rods,packing Strips,ms Body Of Rru,air Cooler Empty Bodies,cbf Filter,corrugated Sheets,drums,blower Motor Frames,ucb Packing Frames,under Frame Cut Up Parts,berth Frames,supports,cylinder Blower Covers,valves,end Shield Covers,traction Motor Yokes,shafts,piston Rings,gears,brake Shoe Heads,brake Gear Items,straps,cotters,springs,equalizing Stays,fan Hub,end Shield,pinions,ms Covers,signal Arms,lc Gate Pipes,ladders,angles,signal Booms,rounds,signal Buckets,pulleys,fabricated Posts,signal Lamp Structures,liners,screws,spikes,air Brake Cylinders,brake Hangers,bss Hangers,battery Boxes,battery Containers,junction And Location Boxes,sleepers Cut Pieces,axle Counter Empty Box,dc-dp Ips Empty Rack ,sge Block Instrument Empty Box ,reset Counter Box,gps Clock ,42 V Rack,transformer Bay,ms Chain Pulley Blocks,beam Scale Parts,idly Cooker With Steam Generator Body,wheel Barrow,fry Pan Single Burner,ms Floor Stand,ms Sliders,ms Body Wet Grinder,fry Pan,jara,ms Ips Rack Rifle Safety Chain,ms Air Pump,foot Spray,antenna,spiral Binding Machine,ms Man Drill,trbc Covers,hand Cart Push Trolley,expresser Fan Guard,ms First Aid Box,hacksaw Frame,tool Box,tie Bars,ci Brake Blocks,composite Brake Blocks,ci Pulleys,buckets,ms Gear Wheels,gym Equipment,roti Maker,bicycle Parts,axle Box,bfr Cut Up Parts,grills,mesh,gate Wheels,girders Cut Pieces,collars,trolleys,foot Plates,signal Point Rods And Any Other Ms-gi-ci Material Present In The Lot With Or Without Attachments Of Nf,ss,rubber,nylon And Plastic. Ms Pan Mortars,wire Claws,wire Baskets,crow Bars,jim Crow,dip Lorry,weld Filling Body,sleeper Hooks,rail Dollies,rail Cutting Frames,augers,pick Axe,tongue For Rails,spades,beaters,ballast Rake,powrahs,rail Cum Road Mono Trolley,case Tin,h.s.lamps,rail Dolly Clips,shovels,trolley Wheels And Similar Gang Man Items Of Sorts And Sizes,with Or Without Attachments.fiber,glass,windows,frp Glass Windows,window Frames Of Sorts And Sizes,broken Or Unbroken,with Or Without Attachments Of Nf Window Shutters. [aluminium - 2 Percent] Note- 1. Nf Material,axles,wheel Discs,and Rails Or Material Not Mentioned In The Description,if Found During The Delivery Are To Be Returned To Railways. 2. Track And Track Fittings Running Through This Area Are Excluded. 3. Nf And Stainless-steel Attachments Are Approximately 0.1 Percent Of The Lot Quantity. 4. Gas Cutting Permitted To Facilitate Loading. At Two Locations- Bin No- 273 To 276 And Bin No 244, Left Side Of Road No- 2 Hsn Code- 72044900. Gst- 18 Percent. Note- Delivery On Actual Weighment Basis Only Special Note: Overload Of The Carrying Capacity Of The Vehicle Will Not Be Permitted At The Time Of Taking Delivery, As Per Motor Vehicle Act 1988
Closing Date30 Jan 2025
Tender AmountRefer Documents
Indian Army Tender
Works
Civil And Construction...+2Civil Works Others, Building Construction
GEM
Corrigendum : Corrigendum Added
Bathinda, Punjab
Details: Constr Of Multipurpose Indoor Hall With Pcc Badminton Court
size 57 Into 30 Into 30 Feet And Gym Size 30 Into 30 Into 15
feet Excavation Of Ground For Foundation 900mm X 600mm
and 1m X 1m In Columns , Pcc 1 Ratio 4 In Foundation For
brick Work With The Thickness Of 100 Mm , Pcc In Floor With
bedding Of 3 Inch Rubble Stone And Pcc Work With 1 Ratio 1
point 5 Ratio 3 Mix M 20 Material Of 100 Mm Thickness ,
brick Work With 1 Ratio 6 Mix Material With Sub B Class Bricks
work In Walls On 230mm Thick Wall , Plaster On Walls With 1
ratio 4 Mix Material Inside And Outside Maintaining
thickness Of 15 Mm , Steel Bars In Column And Beam , Rcc
work In Column And Beam With 1 Ratio 1 Point 5 Ratio 3 Mix
m20 Material , Pillar Column Of 6 Inch Ms Round Pipe 4mm
to 5mm Wall Thick With Base Plate On Bothside Of 16 Inch
x16 Inchx10mm Thickness Height Of Pillar 22 Feet Include J
bolts For Grouting Of Pillars 1mtr Long , Trusses Made Of 2
into 4 Inch Ms Pipe Of Wall Thickness 3 To 4 Mm Thick
including Cutting Jointing Complete , Purlin Of 2 X 4 Inch
rectangular Ms Pipe Of Thickness 3 To 4mm , Rafters Of 3x3
inch Square Pipe Of Thickness 3 To 4mm , Ms Pipe Support
for Side Covering With 2x1 Point 5 Inch Pipe Of Thickness 3 To
4mm , Cross Bracing For Structure Of 2x4 Inch Ms Pipe Of
thickness 3mm To 4mm , Aluminium Windows 6x6 Feet 06
nos And Doors 02 Nos Including All Accessories , Roof And
side Covering With Colour Coated Aluminium Galvanized
sheet 0. Point 45 To 0 Point 5 Mm Thick Including Claddings
of 6 Into 6 Inch Size At All Corners Of The Shed , Electrification
work Including Fans 8 Nos And Tube Lights 12 Nos And Switch
sockets 20 Points , Ventilation Exhaust Fan 06 Industrial
type Fixed On Top Of The Roof Incl All Attachments , Painting
work Including Enamel Paint On Fabricated Work And
whitewash On Cement Wall Inside And Outside , Badminton
court Rubberized Mat Surface , Treadmill Commercial ,
dumbbells 2 And 4 And 5 And 10 Kg Weight , Rubberized
weight Including Rods , Cross Trainer Commercial , Incline
and Decline Bench , Exercise Bike Commercial , Gym Mat
Closing Date20 Jan 2025
Tender AmountRefer Documents
This is an estimated amount, exact amount may vary.
Tamil Nadu Generation And Distribution Corporation Limited - TANGEDCO Tender
Works
Electrical Works...+1Electrical and Electronics
Eprocure
Kanyakumari, Tamil Nadu
Details: Works contract for execution of providing 1)Improvement estimate for providing 2 nos 11KV ABSwitch in Various locations in Thickanamcode feeder under Thickanamcode Section. 2)Improvement estimate for 8nos 8mtr PSC pole in various DTs in various locations under Thuckalay Section. 3)Improvement estimate for newly proposed 1no double pole 11KV AB Switch at Mulavilai under Thiruvattar Section. 4)Improvement estimate for newly proposed 6nos single pole 11KV AB Switches in 11KV Arumanai Feeder under Thiruvattar Section. 5)Improvement estimate for 3mos 9.14 mtr RCC poles into 9mtr PSC poles in Muthalakurichy SS II FI/2,3,4 under Thuckalay Section. 6)Improvement estimate for strengthening of existing LT conductor ACSR 7/2.11 into ACSR 7/3.35 in FI/1 to FI/15 in Puliyanvilai SS 100KVA under Thiruvattar feeder. 7)Improvement estimate for newly proposed 1no single pole 11KV AB Switch at Thattanvilai under Thiruvattar Section. 8)Improvement estimate for improving tailend voltage to be changed with existing Panavilai SS III 25KVA tobe enhanced to 63 KVA DT by secreating GH SS in Thuckalay feeder under TKY Section. 9)Improvement estimate for improving tailend voltage by secreating in Puliyoorkurichy SS V into by providing 1no 63KVA DT in Thuckalay feeder under TKY Section. 10)Improvement estimate for newly proposed 100KVA DT for improving tail end voltage by segregating Puliyoorkurichy SS I in Thuckalay feeder under Thuckalay section. 11)Improvement estimate for replacement of deteriorated 4nos 9.14 mtr RCC pole into 9mtr PSC pole and 1no 9 mtr into 9m PSC pole in various locations under MCL Section. 12)Improvement estimate for newly proposed 1no 63KVA DT for Improving TailEnd Voltage in Kulasekharam Market area in Thiruvattar Feeder under U KLm Section. 13)Improvement estimate for newly proposed 1nos 25 KVA DT at Veeyanoor Substation Quarters in 11KV Chandam Feeder under Thiruvattar Section. 14)Improvement estimate for strengthening of existing aged LT conductor ACSR 7/2.50 into ACSR 7/3.35 at Mathiravilai Kurusady Area for improving tail end voltage under TKD Section. 15)Improvement estimate for 4nos 9.14 mtr RCC poles into 9mtr PSC poles in 11KV Charode and CWSS feeders and 1no 8mtr RCC pole into 8mtr PSC for detoriated in various locations under Thuckalay Section. 16)Improvement estimate for improving tailend voltage suply in single phase connected load in Kuttakarai SS 100 KVA by stringing addl 2phase wire for reulating normal voltage at Kuttakarai area under TKY section. 17)Improvement estimate is prepared for the erection of 11 KV HT feeder link line between 11KV Mulagumoodu Feeder and 11KV Eraniel Feeder under Moolachel Section. 18)Improvement estimate for strengthening of existing HT conductor ACSR 7/2.5 into ACSR 7/4.09 in TKY SS 1,4,5 to Perumal Kovil under Thuckalay Section. 19)Improvement estimate for strengthening of existing LT conductor ACSR 7/2.11 into ACSR 7/3.35 in F2/1 to F2/23 in Puliyoorkurichy 250 KVA under Thiruvattar feeder. 20)Improvement estimate for replacement of 1nos 9mtr PSC pole and 6no 8mtr PSC pole and 2nos RSJ pole insertion in various locations in various DT under VCI section. 21)Improvement estimate for strenthening of existing LT conductor ACSR 7/2.59 into 7/4.09 and insertion of 9mtr PSC pole in various DT in Kothanalloor Feeder under MCL section. 22)Improvement estimate for insertion of 1no 9mtr PSC pole and 1no existing 8mtr pole into 9mtr PSC pole and 1no 9mtr stud pole in 11KV Chandam feeder under Moolachel Section. 23)Improvement estimate for replacement of deteriorated 8nos 8 mtr RCC pole into 8mtr PSC pole and 1no 8 mtr insertion PSC pole in various loacation under MCL Section. 24)Improvement estimate for replacement of 3nos RSJ pole 5nos 9mtr PSC poles and 2nos 8mtr PSC deteriorated poles in various locations under VCI Section. 25)Improvement estimte for replacement of 2nos 9.14 mtr RCC pole into RSJ Fabricated and 2nos damaged RSJ pole in low ground clearance in various loacation under MCL section. 26)Improvement estimate for replacement of deteriorated 4nos 8mtr PSC pole into 8mtr PSC poles in Poonangaparambu SS III 25KVA in various locations under MCL Section. 27)Improvement estimate for providing linkline between two 11KV feeders(Thickanamcode & Kattuvilai) Near Railway Bridge under Thickanamcode Section. 28)Improvement estimate for replacement of 6nos deteriorated RSJ poles and 1nos Tubular in various locations under Thuckalay Section. 29)Improvement estimate for provision of 3 feeders nos additional 11KV rotating AB Switch in existing 11KV Aloor & Mulagumoodu and Kothanalloor Feeders 110/11 KV SS Campous Thuckalay under Substation Thuckalay. 30)Improvement estimate for 11KV AB Switch in to 11KV Center Rotating AB Switch in Thiruvattar-Arumanai Tie Switch in 110/11 KV Sub station Veeyanoor. 31)EOS to 1no IIIB INDL additional load toTmy.Jaya Paulcy Bai at Ottalivilai by providing 250KVA DT under Thiruvattar Section. 32)Estimate for 1no IIIB service to Thiru.Sreekutty Enterprices at Marunthukottai under Thuckalay Section. 33)Improvement estimate for replacement of 6 nos deteriorted 9mtr PSC poles in various DTs under MCL Section. 34)Natural Calamity estimate for the replacement of damaged 1no single pole structure in Aanayadi Cashew Industries SS 100KVA due to fallen of Rubber tree under Thiruvattar Section. 35)Eos for 1no III B INDL additional load service to Thiru.Renish at Sadayalputhoor Rod at Peyode by providing 100KVA in 11KV Kattimancode feeder under Vellichanthai Section. 36)Estimate for 1no industrial SC to Tmy.A.Nabisath Beevi at main road Tiruvithamcode under Moolachel Section. 37)Eos to 1no IIA OHT service to The President Kumarankudi Village Panchayat by providing 1no 63KVA DT at Poovancode under Thiruvattar Section. 38)DCW estimate for shifting of existing 1No 100 KVA distribution transformer in Tholichal SS I and 1no 9mtr PSC poles as per the request of Thiru.Vishnu Prasad at Pullanivilai under Thiruvattar Section. 39)Improvement estimate for providing 1No 63KVA DT improving tail end voltage in Thirunainarkurichy SS I in 11 KV Vellichanthai Feeder under VCI Section. 40)Improvement estimate for providing 1No 63KVA DT Improving Tail end voltage to avoid electical accident in Vellamodi Junction in 11KV Kattimancode Feeder under VCI Section.Kanyakumari Electricity Distribution Circle – Regarding.
Closing Date4 Jan 2025
Tender AmountRefer Documents
Tamil Nadu Generation And Distribution Corporation Limited - TANGEDCO Tender
Works
Electrical Works...+1Electrical and Electronics
Eprocure
Kanyakumari, Tamil Nadu
Details: Works Contract for the execution of 1)Improvement estimate for replacement of deteriorated 6no 8mtr PSC pole at loc FI/19, 20&49 and FII/2,4&5 in Simon Nagar SS II 250 KVA under Asaripallam Section.2)Improvement estimate for replacement of deteriorated 5no 8mtr PSC pole at various locations under Asaripallam Section. 3)Eos to 1no LTCT SC to The Principal Commissioner of Income Tax at Door No.329 in Guest House SS I 500 KVA and proposed 1no 250 KVA DT under Asaripallam Section. 4)Eos to 1no TYSY to Tmy.Ramani Kannan under Asaripallam Section. 5)Improvement estimate for replacement of 6nos damaged 8mts PSC pole at loc.FI/10 in TKM SS V & FII/1 in TKM SS VIII, FI/10 in Pambanvilai SS I, FII/12 in Thoppoor SS II, FII/12,13 in Ottayalkudy under Asaripallam Section. 6)Improvement estimate for replacement of 7nos damaged 8mts PSC pole at loc.FI/8,9 in Thoppoor SS IV, FII/14,15 in Vembanoor SS VII, FI/13 in Paruthivilai Channelkarai SS under Asaripallam Section.7)Improvement estimate for replacement of deteriorated 4no 9mtr PSC pole at loc. FII/2 in Thammathukonam SS IV & FI/9 in Asaripallam SS I, FI/7 in Charlespuram SS I, FI/2 in Vembanoor SS IV under Asaripallam Section. 8)Improvement estimate for replacement of deteriorated 6no 8mtr PSc in various locations under Asaripallam section.9)Improvement estimate for strengthening of conddctor from ACSR 7/2.11 to AAAC 7/2.50 at Keezhaperuvilai SS 250KVA under Parvathipuram Section. 10)Improvement estimate for replacement of aged conductor from ACSR 7/2.11 to AAAC 7/2.50 at Kottavilai SS 250 KVA under Parvathipuram Section. 11)Estimate proposed for 1no 63KVA DT to avoid overloading of North Kannakurichi SS 100 KVA in KV Kallukatti Feeder under Rajakamangalam Section. 12)Estimate for proposed 1nos Erumbukadu SS 25KVA DT under Rajakamangalam Section. 13)Estimate for proposed 2nos 25KVA DT to avoid overloading of Sreekrishnapuram SS II 100 KVA in Kallukatti Feeder under Rajakamangalam Section. 14)Eos to 11No Additional Street light SC no:R6-952 of The President, Village Panchayat, Melasankarankuzhi in Pambanvilai under Asaripallam Section. 15)Eos to 13Nos new street light SC to The President, Village Panchayat, Melasankarankuzhi in Pambanvilai under Asaripallam Section. 16)Eos to 13Nos new street light SC to The President, Village Panchayat, Melasankarankuzhi in Pambanvilai SS I 100KVA under Asaripallam Section. 17)Eos to 16nos new street light sc to The President, Village Panchayat, Melasankarankuzhi in Thoppoor SS I 100KVA under Asaripallam Section. 18)Eos to 7nos additional street light SC NO:R7-474 of The President, Village Panchayat, Melasankarankuzhi in Thoppoor SS IV 100KVA under Asaripallam Section. 19)Eos to 4nos additional street light SC NO:V7-123 of The President, Village Panchayat, Melasankarankuzhi in Vembanoor SS I 100KVA under Asaripallam Section. 20)Eos to 4nos additional street light SC NO:V2-323 of The President, Village Panchayat, Kelasankarankuzhi in Parappuvilai SS I 100KVA under Asaripallam Section. 21)Eos to 7nos additional street light SC NO:R8-631 of The President, Village Panchayat, Melasankarankuzhi in Pambanvilai SS VI 100KVA under Asaripallam Section. 22)Eos to 7nos additional street light SC NO:R2-529 of The President, Village Panchayat, Melasankarankuzhi in Pambanvilai SS VI 100KVA under Asaripallam Section. 23)Eos to 3nos additional street light SC NO:R6-951 of The President, Village Panchayat, Kelasankarankuzhi in Parappuvilai Chanelkarai SS III 100KVA under Asaripallam Section. 24)Eos to 6nos additional street light SC NO:V2-838 of The President, Village Panchayat, Kelasankarankuzhi in Vembanoor SS VIII 100KVA under Asaripallam Section.25)Eos to 1no non domestic to M/S Amzes trading Private limited under parvathipuram Section. 26)Eos to 1no new street light of 8 loc in Iswarya Garden to The Commissioner, Nagercoil Corporation under PVM Section. 27)Eos to 1no new street light of 7 loc in Iswarya garden to The Commissioner, Nagercoil Corporation under PVM Section. 28)Eos to 1no new st.light of 5 locs in Antony Street to The Commissioner, Nagercoil Corporation under PVM Section. 29)Eos to 1no new st.light of 4 loc in Thendral Nagar to The Commissioner, Nagercoil Corporation under PVM Section. 30)Eos to 1no Sc connection to Vijaya Chandra Suthakar under PVM Section.31)Improvement estimate for replacement of aged conductor from ACSR 7/2.11 to AAAC 7/2.50 at Vimal Nager SS 250KVA under PVM Section. 32)DCW estimate for 1no 9mtr PSC pole as per request of Thiru.Ganapathy at Kattayvilai under PVM Section. 33)DCW estimate for shifting of 1no 9mtr RCC pole as per request of Thiru.Kuttalam at Ramavarmpuram under PVM Section. 34)DCW estimate as per request to Thiru Freedahelan under PVM Section.35)DCW estimate for shifting of 1no 8mtr PSC as per the request of Tmy.Geetha under PVM Section. 36)DCW estimate fro shifting of 1no 9mtr PSC pole as per request of Thiru.Rajan at Pallivilai under PVM Section. 37)DCW estimate for deviation of LT line as per request of Tmy.Kasal Inba Lyla at Elathaiyadi under PVM Section. 38)DCW estimate for shifting of 1no 9mtr RCC pole as per request of Thiru.Chandran at Pallivilai under PVM Section. 39)DCW estimate for shifting of 1no 8mtr PSC as per the request of Tmy.Sobana Kumari under PVM Section. 40)Eos to 1no TYSY to Thiru.Edwin Jose at lake view colony under PVM Section. 41)Eos to 1no TYSY to Thiru.Suresh Raj at Ulavurkonam under PVM Section.42)Eos to 1no ND PAL SC 114-012-1493, The Correspondent, The Pineer School MS Road under PVM Section. 43)DCW estimate as per request to Thiru Commissioner under PVM Section. 44)DCW estimate as per request to Thiru Agens Sooriya Raja under PVM Section. 45)DCW estimate for shifting of 1no 8mtr PSC pole as per request of Thiru.Vijaya Kumar under PVM Section. 46)DCW estimate for shifting of 1no 8mtr PSC pole as per request of Thiru.SelvaRaj Christopher under PVM Section. 47)DCW estimate for shifting of 1no 9mtr and 1no 8mtr PSC pole and deviation of HT line as per request of Thiru.M.Thurai Pandian at Iswrya Garden under Parvathpuram Section. 48)DCW estimate for shifting of LT line as per request of The President VP, ward 6 Kaniyakulam under PVM Section. 49)DCW estimate for shifting of 1no 9mtr PSC pole Thiru.Selvan at Kesavathiruppapuram under PVM section. 50)DCW estimate for shifting of 1no 8mtr PSC pole as per request of The President. VP Kaniyakulam under PVM Section. 51)Estimate for 1no TYSY SC to Thiru.Maria Jose at SS Nagar Under PVM Section. 52)Estimate for 1no TYSY SC to Thiru.Jegan Under PVM Section. 53)Eos to 1no TYSY SC to Tmy.Jemila Rani at Balaji Nagar under PVM Section. 54)Estimate for 1no TYSY SC to Thiru.Prabhu Under PVM Section. 55)DCW estimate for rectification of Nagammal Mill SS/25KVA Distribution Transformer Structure 1no 9mtr PSC pole and 1no 8mtr PSC pole due to dashing of Private vehicle TN 74AV4777 on 09.05.24 undder Parvathipuram Section. 56)Improvement estimate for strengthening of condductor from ACSR 7/2.11 to AAAC 7/2.50 at Keezhaperuvilai SS 250KVA under Parvathipuram Section. 57)Improvement estimate for replacement of aged conductor from ACSR 7/2.11 to AAAC 7/2.50 at Kottavilai SS 250 KVA under Parvathipuram. Section. 58)Eos to 1no TYSY SC to Thiru.Anand at Goldden Nager under Parvathipuram Section. 59)Eos to 1no TYSY SC to Thiru.Gopalakrishnan at Kaniyakulam under Parvathipuram Section.60)Eos to 1no IIIA1 S to Thiru.Tamil Sekvan at Railway Nagar, Pallivilai under Parvathipuram Section. 61)DCW estimate for shifting of 2nos 8mtr PSC pole and 1no fabricated pole 36 feet at loc no A,D,E in Rajeev Gandhi SS 100KVA as per request of Thiru.Jacob Parama Sigamony near Franklin Hospital under Parvathipuram Section. 62)Natural calamity to be replacement of 10 nos 8mtr PSC poles and line materials with ACSR 7/2.59 sq mm & 2nos 8m PSC stud pole at Pillayarvilai SS II 100 KVA DT due to fal on coconut tree under Rajakkamangalam Section.63)Natural calamity estimate for the replacement of damaged 4nos 8mtr PSC pole at loc no :FI/16,17 of Vadalivilai SS I 100KVA and loc no: FI/42,44 of Poochivilagam Ss I 100 KVA due to fallan of Coconut tree over LT line under Eathamozhy Section. 64) Natural Callamity estimate for the replacement of damaged 5nos 8mtr PSC pole at Loc no FII/22,23,24,26,30 in Amachiyarvilai SS II 63KVA due to fallen of coconut tree over LT Line under Eathamozhy Section. 65)DCW estimate to S.Kalanvathi, Kayankulam under PVM Section. 66) DCW estimate for Freeda Helen Dom under Parvathipuram Section. 67)DCW estimate for deviation of LT at loc noc A to D in Kayamkulam SS Ii 100KVA as per the request of Thiru.Siddhuvar Near four way road under Parvathypuram Section. 68)Eos to 1no TYSY SC to Tmy.P.W.Jebamalar at SS Nagar under PVM Section. 69)Natural Calamity estimate for the replacement of damaged 1no double pole ABSwitch near Panchayat Office of 11 KV kaliyankadu feeder under Parvathipuram Section. 70)Natural calamity estimate for replacement of damaged 1no 9mtr PSC pole at loc no:FI/4 of Peruvilai SS II 100KVA due to heavy rain on 16/10/2023 under Parvathypuram Section. 71)DCW estimate for shifting of 1no RSJ 36" at loc ETY-298 and dismantling of LT 8mtr PSC pole at loc FII-5 as per the request of the Assistant Engineer, Highways, Nagercoil in the Road widening at Eathamozhy main road at Eathamozhy SS IV 250 KVA in Eathamozhy Feeder under Eathamozhy Section. 72)Estimate for new street light service connection in kumarapuram area as per the request of the Executive Officer, Aralvaimozhy TP under Aralvaimozhy Section. 73) Eos to 1No Tariff V new LTCT service to Tmy.Viaishnavathi Kaliyankadu under Parvathipuram Section. 74)Eos to 1no Tariff III B service to Thiru.Robin Xavier at Chanthavilai Road under Thovalai Section. 75) Capital estimate for mew street light service connection IIA in Sc No.125-003-1815 as per request of The commissioner, Nagercoil Corporation at poochivilagam SS II 63KVA under Eathamozhy Section. 76)Capital estimate for mew street light service connection IIA in Sc No.125-003- as per request of The commissioner, Nagercoil Corporation at poochivilagam SS I 100KVA under Eathamozhy Section. 77) Capital estimate for mew street light service connection IIA in Sc No.125-002-380 as per request of The commissioner, Nagercoil Corporation at poochivilagam SS II 63KVA under Eathamozhy Section. 78) Eos to 1no IIIA indl new service connection to Thiru.Nivas at Melasoorankudy proposed new 25KVA DT under Eathamozhy section.in Kanyakumari Electricity Distribution Circle.
Closing Date2 Jan 2025
Tender AmountRefer Documents
2321-2330 of 2325 archived Tenders