Public Works Department Tender
... More
The PWD has issued a formal invitation for competitive bids for the Public Works Department project, for Maintenance Of Street Light, High Masts, Subways, Underdeck And Fob Lights On Delhi Pwd Roads Under Pwd Emd South West. in New Delhi, Delhi, with an estimated contract value of Rs. 5,90,495. The bid opening date for this tender is 29-05-2025 and the last date for bid submission is 09-06-2025. Interested bidders for Public Works Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Costs
EMD
₹ 11,810Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Maintenance Of Street Light, High Masts, Subways, Underdeck And Fob Lights On Delhi Pwd Roads Under Pwd Emd South West.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PWD_273054_1Tender No
11/EE (E)/PWD EMD South West/2025-26(2nd call)Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://www.pwddelhi.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supplying and fixing 4 Nos. 25mm dia X 750mm long GI foundation bolt (EN8 grade) with nuts, washer including 2 Nos. template of 4mm thick size 320mm x 320mm with 4 nos. 28mm dia holes, to match with PCD of Pole base plate as reqd. (For 12mtr & 10 mtr. Pole)
1
2057
-
... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
-
-
-
... More
63 mm dia (OD-63 mm & ID-51 mm nominal)
7
256
-
... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
20
72
-
... More
Dismantling of Octagonal GI Pole of 10-12 Mtr Height with street light Fittings and existing foundation i/c cutting of foundation bolts etc. and making good smooth surface & Re-errection of this pole on new foundation with street light fittings by suitable means i/c testing , commissioning etc. as required.
1
7892
-
... More
Cutting of hard rock/road/ PCC for laying of UG cable from existing dismantled foundation to new foundation with the help of hilty/ hammer etc. i/c making good by laying in position cement concrete 1:2:4: (1 Cement :2 coars sand : 4 graded stone ) of size 0.2 B x 0.2 D mtr etc. as required.
7
509
-
... More
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
... More
4 X 25 sq. mm
2
3146
-
... More
Replacement of old unserviceable of the following accessories on the existing high mast suitable for fixing luminaires complete with winch assembly, SS wire rope with U clamp of both the ends and window cover of 20 Mtr pole i/c connections, testing, commissioning etc. i/c complete with greasing the pinions, making required holes to fix the same i/c less credit dismantle and inserviceable for same etc. as reqd.
-
-
-
... More
winch assembly
1
37791
-
... More
Supplying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade aluminium unarmoured cable of following size for connection of the fitting to the pole as required.
-
-
-
... More
3 x 4 Sq.mm
2400
113
-
... More
Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg., suitable tiltable fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). on exsiting high mast by suitable means etc.
-
-
-
... More
350 watt
30
8005
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%