If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 May 2025
Closing Soon30 May 2025
Tender Amount₹ 7,82,487 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
b) 6 x 1.5 sq. mm

70

181

-

... More
c) 3 x 4 sq. mm

120

206

-

... More
d) 6 x 4 sq. mm

70

396

-

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm

100

223

-

... More
b) 25 mm

80

256

-

... More
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.Dismantling the Existing if any a) 1 or 2 Module (75mmX75mm)

10

298

-

... More
b) 3 Module (100mmX75mm)

10

327

-

... More
c) 4 Module (125mmX75mm)

10

343

-

... More
d) 12 Module (200mmX150mm)

1

547

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Dismantling the Existing if any a) 5/6 amps switch

66

103

-

... More
b) 3 pin 5/6 amp socket outlet

2

69

-

... More
c) 6 pin 15/16 amp socket outlet

14

137

-

... More
d) 15/16 amp switch

14

121

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Dismantling the Existing if any. a) Single pole

20

256

-

... More
b) Single pole and neutral

8

599

-

... More
Fabrication, supplying, installation, testing & Commissioning of cubical type Feeder Pilllar panel With IP 65 Rating, upto 300 mm depth made out of 2mm thick (14 SWG) CRCA MS Sheet having detachable gland Plates, floor mounted, compartmentalized , front operation, dust & vermin proof duly powder coated with proper locking arrangement complete with 400 Amp. TPN high conductivity aluminum alloy bus barwith DMC/SMC supports, continuous earth bar, interconnections, connections and providing & fixing of angle iron stand made out of 50mm X 50mm X 6mm thick M.S. Angle iron to suit the size of feeder pillar with 4 nos. 50 cms. legs grouted in cement concrete duly painted with one coat of red oxide & two coats of superior quality enamel paint etc. as reqd at site. (To be fabricated from CPRI approved fabricator.)

1.9

32071

-

... More
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. a) 250 Amp, 25 KA, TPMCCB

1

12984

-

... More
b) 125 Amp, 16 KA, TPMCCB

4

4821

-

... More
c) 63 Amp DPMCB 10 kA breaking capacity

8

1264

-

... More
d) Digital type voltmeter with seperate selector switch

1

649

-

... More
e) Digital type Ammeter with seperate selector switch and CT's of class accuracy 1.0

1

795

-

... More
f) Phase indication lamp 0-240 V A.C.

1

193

-

... More
Cleaning, Servicing removing dust & painting of exisiting electrical panel by removing all the existing power cables making connections,. Thimbling, taping in each window of the panel etc. as required.

1

4238

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

4

6855

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

25

244

-

... More
Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Al armoured power cable of 1.1 KV grade conforming to IS 7098 (Part -1) of following size on wall surface/ Cable Tray as required. a) size 3½ X 70 sq. mm

100

1212

-

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. a) 120 mm dia (OD-120 mm & ID-103 mm nominal)

42

248

-

... More
Supplying and Laying of XLPE, Aluminum armored conductor cable in the existing pipe as reqd i/c termination of cable with suitable size thimble at both end etc as required complete at site. a) size 3½ X 70 sq. mm

50

1139

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3½ X 70 sq. mm (38mm)

2

468

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

340

42

-

... More
SH-II (Fans and Fittings and UPS) Supplying, installation, Testing & Commissioning of Recessed Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). The Existing Fitting must be dismantled if any. a) 36 Watt Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)

23

2502

-

... More
Supplying, installation, Testing & Commissioning of LED surface Down lighter Round SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) The Existing Fitting must be dismantled if any. a) 22 Watt Powder coated die cast /Extruded aluminum Body including trim

20

898

-

... More
Supplying, installation, testing and commissioning of oscillating type 400 mm sweep Hi-speed cabin fan/wall bracket fan with mounting based closed mesh guarded blades and speed regulator and two nos. strings for operation of regulator & swing action suitable for use on 230V 50Hz single phase supply complete as required.The existing fitting must be dismantled if any.

15

2375

-

... More
Supplying, installation, Testing & Commissioning of 1200mm LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).The Existing fitting must be dismantled if any. a) 36 Watt Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)

19

698

-

... More
Supplying, installation, Testing & Commissioning of 600 mm LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). The existing fitting must be dismantled if any. a) 36 Watt Powder coated die cast / Extruded aluminium Body (Thickness≥ 1.20 mm)

1

698

-

... More
Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc a) 3 KVA

2

52051

-

... More
S/I/T/C of 150 mm sweep non metalic vantilating fan with louvers/ shutters suitable for 220-230 V AC supply i/c making hole in the wall to suit the size and making good the damage, repair, connection with 3-core wire etc. as required.

2

1974

-

... More
Credit for following old/dismantle material received from day maintenance in the existing electrical installation etc. as reqd i/c dismantling & removal from site .(Labour for dismantling is already include in above items) (Dismantle Material receipt statement will be maintained by agency in Task Register). a) Assorted Tube fitting /Downlighter/2*2 fittings

60

-20

-

... More
b) Assorted Ceiling Fans/Wall Fan

3

-200

-

... More
c) Assorted Ventilation Fans (Plastic Body)

2

-100

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.