If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
National Environmental Engineering Research Institute - NEERI Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Nov 2024
Closing Date4 Dec 2024
Tender Amount₹ 2,26,049
Costs
EMD
₹ 4,600Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Annual Maintenance Contract Of Air Conditioners Installed At Csir Neeri Zonal Centre Delhi
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CSIR_214546_1Bid Award Id
ViewTender No
50(46)/2024-25/WTender Authority
National Environmental Engineering Research Institute ViewPurchaser Address
-Website
http://csir.res.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Scan copies of EMD receipt, NIT, LOT, GCC and other credential documents.
Scan copies of EMD receipt, NIT, LOT, GCC and other credential documents.
BOQ Items
... More
WINDOW AIR CONDITIONER (Fixed Speed), Cooling Capacity: 1.5TR (Make: HITACHI)
3
-
-
... More
CASSETTE TYPE AIR CONDITIONER (Fixed Speed), Cooling capacity: 2.0 TR (Make: DAIKIN)
43
-
-
... More
CASSETTE TYPE AIR CONDITIONER (Fixed Speed), Cooling capacity: 1.5 TR (Make: DAIKIN)
7
-
-
... More
ADDITIONAL GAS CHARGING: Supply of refrigerant gas and Gas charging work in SPLIT/CASSETTE type air conditioners as per required quantity & Pressure as per standard operating procedure related for gas charging work and complete as required
-
-
-
... More
Refrigerant, Freon-22
5
-
-
... More
Refrigerant, Freon-32
10
-
-
... More
DUAL SECTION MPP RUNNING CAPACITOR: Supply and fixing of brand new dual section MPP running capacitor (Reference Standard :IS 2993/IEC 252), Burst Proof, DAT series, Three Output terminals marked with H, F & C) with cylindrical aluminium can construction of following capacity to the compressor fitted in outdoor unit assembly of air conditioner including removing of defective capacitor and required wiring connections for newly replaced capacitor along with other accessories as per standard procedure and complete testing of the same, complete as required
-
-
-
... More
(45μF+4.0μF) ±5%, 50/60 Hz, 440 Vac
4
-
-
... More
(50μF+5.0μF) ±5% 50/60 Hz, 440 Vac
2
-
-
... More
REPAIRING OF PRINTED CIRCUIT BOARD (PCB) ASSEMBLY OF AIR CONDITIONERS: Repairing of defective printed circuit board assembly fitted in Indoor/Outdoor unit of HI WALL SPLIT AIR CONDITIONER (FIXED SPEED), Cooling capacity: 1.5/2.0 TR, Make:LG/Daikin/Hitachi air conditioners including dismantling of old defective PCB and refixing of the same after completion of repairing work along with any other accessories such as room temperature and coil temperature sensor, PCB transformer, Display Kit etc (if required), wiring connections of PCB and testing of PCB assembly to make it properly functional, complete as required
5
-
-
... More
THERMAL INSULATION SLEEVE: Supply and fixing of elastomeric nitrile rubber thermal insulation sleeve (preformed pipe section), Class- 0 of Inner dia. and thickness as given below, over existing Indoor-Outdoor copper refrigerant pipe connection of air conditioner as per the instructions of Engineer, CSIR-NEERI, Nagpur. Make: Any reputed make with prior approval of engineer CSIR-NEERI.
-
-
-
... More
INNER DIA. 5/8'' WALL THICKNESS 6.0 MM
25
-
-
... More
INNER DIA. 1/2'' WALL THICKNESS 6.0 MM
25
-
-
... More
INNER DIA. 1/4'' WALL THICKNESS 6.0 MM
50
-
-
... More
DISMANTLING OF AIR CONDITIONER: Dismantling of Hi Wall Split air Conditioners, Cooling Capacity: 1.5/2.0 TR as per standard pracitice recommanded by the Air conditioner manufacturer includes required pump down operation, dismantling of Indoor-Outdoor unit, complete copper piping and electrical wiring, Base plate of ID Unit and mounting stand of OD unit, Shifting of dismantled material as per instructions of Engineer, CSIR-NEERI, at any location of institute premises.