Govind Ballabh Pant Hospital Tender
... More
The Govind Ballabh Pant Hospital has issued a formal invitation for competitive bids for E-tender For The Procurement Of Coronary And Peripheral Stents For Cardiology Department in Central Delhi, Delhi, with an estimated contract value of Rs. 19,00,00,000. The bid opening date for this tender is 18-07-2024 and the last date for bid submission is 30-08-2024. Interested bidders for Govind Ballabh Pant Hospital tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Govind Ballabh Pant Hospital Tender
Healthcare and Medicine
Eprocure
Opening Date18 Jul 2024
Closing Date30 Aug 2024
Tender Amount₹ 19,00,00,000
Costs
EMD
₹ 38,00,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
E-tender For The Procurement Of Coronary And Peripheral Stents For Cardiology Department
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_GBPH_259681_1Bid Award Id
ViewTender No
FNo.411/PUR/GBP/PS/OTE/2024-26Tender Authority
Govind Ballabh Pant Hospital ViewPurchaser Address
-Website
http://http://gbpant.delhigovt.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Balloon-mounted, polymer-free, Sirolimus-eluting stent
-
-
-
... More
J. Peripheral Stent Grafts
-
-
-
... More
Balloon-mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform ultrathin struts (up to 60 microns) of varying lengths including stent length of 8 mm or less, with at least one publication of the quoted product in PubMed indexed journal.
-
-
-
... More
Over the wire, 0.035” wire compatible, nitinol/ elgiloy peripheral self-expanding stent of diameter 11-14 mm of varying lengths
-
-
-
... More
Self-expandable Aortic Stent graft expandable to 24 mm
-
-
-
... More
Self-expandable peripheral stent dedicated for SFA/ Popliteal and across joint intervention in all diameters with lengths 150 mm or more
-
-
-
... More
Peripheral stainless-steel stent of diameter 5-10 mm and length 20- 60 mm
-
-
-
... More
Self-expandable Peripheral Stent graft of all diameters and varying lengths
-
-
-
... More
Balloon mounted, Everolimus eluting stent with biodurable/biostable polymer* on a Non-stainless-steel platform
-
-
-
... More
Balloon mounted, Everolimus eluting stent with biodegradable polymer on a Non-stainless-steel platform with uniform ultrathin struts (less than 60 microns)
-
-
-
... More
Balloon mounted, Everolimus eluting stent on a Non- stainless-steel platform with ultrathin struts (up to 80 microns) and diameters inclusive of 2.0 mm to 4.0 mm of varying lengths, with at least one publication of the quoted product in Pubmed indexed journal.
-
-
-
... More
Aortic Stent graft Self Expandable Tubular Diameter 23 mm or less and 34 mm or more with Delivery System.
The manufacturer should agree to supply the size customized to the patient’s anatomy based on CT imaging
-
-
-
... More
For publication of the quoted product in Pubmed indexed journal, only original research article will be considered. Case reports, case series will not be accepted. The relevent publications highlihting the quoted product must be attached along with technical literature.
-
-
-
... More
Balloon Expandable Stent up to 30mm in Diameter
Stents are Composed of 0.013” platinum-iridium wire arranged in either an 8 zig or 10 zig patterns
Covered and Unmounted
-
-
-
... More
Balloon-mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform ultrathin struts (up to 80 microns) of varying lengths including stent lengths of 48 mm or more across all diameters from 2.5mm to 4.0 mm, with at least one publication of the quoted product in Pubmed indexed journal.
-
-
-
... More
Self-expandable covered stent of diameter 6mm-14mm and length 20-70 mm
-
-
-
... More
E. Peripheral vascular stents (Carotid stents self-expandable)
-
-
-
... More
Balloon-mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform ultrathin struts (up to 60 microns) and diameters inclusive of 2.25 mm to 4.5 mm or more of varying lengths.
-
-
-
... More
Balloon-mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform strut thickness greater than 80 microns of varying lengths including stent length of 8 mm or less
-
-
-
... More
Balloon-mounted, polymer-free, Everolimus/Biolimus eluting stent.
-
-
-
... More
Peripheral stainless-steel stent high radial strength of diameter 15-24 mm
-
-
-
... More
Pre-mounted Balloon Expandable Peripheral stent diameters upto 30 mm or more in various lengths
-
-
-
... More
B. Medicated Coronary stent – SIROLIMUS ELUTING
-
-
-
... More
Balloon mounted, Everolimus eluting stent with biodegradable polymer on a Non-stainless-steel platform with uniform thin struts (60-80 microns), with at least one publication of the quoted product in Pubmed indexed journal.
-
-
-
... More
0.018” wire compatible nitinol/ elgiloy peripheral self- expanding stent of all sizes and variable lengths
-
-
-
... More
PTFE covered balloon expendable Cobalt Chromium stent with high radial strength, of length 18 to 57 mm and diameters up to 35 mm
-
-
-
... More
Balloon mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform thin struts (61-80 microns) and diameters inclusive of 2.0 mm to 4.0 mm of varying lengths, with at least one publication of the quoted product in PubMed-indexed journal.
-
-
-
... More
D. Other Coronary Stents
-
-
-
... More
Iliac extension for Aortic stent graft
-
-
-
... More
I. Peripheral Drug eluting stent
-
-
-
... More
Balloon expandable Stent graft with PTFE expandable to 24 mm
-
-
-
... More
Balloon mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform thin struts (61-80 microns) and diameters inclusive of 2.25 mm to 4.5 mm or more of varying lengths.
-
-
-
... More
Over the wire, 0.035" wire compatible, self-expandable stent of braided construction, with higher flexibility and improved compression resistance, of diameter 5-24 mm variable lengths
-
-
-
... More
Balloon Expandable Stent up to 30mm in Diameter
Stents are Composed of 0.013” platinum-iridium wire arranged in either an 8 zig or 10 zig patterns
Un-Covered and Pre-mounted on Balloon in Balloon (Two Balloons on same shaft)
-
-
-
... More
Balloon-mounted, Sirolimus-eluting stent with biodegradable polymer on a Non-stainless-steel platform with uniform ultrathin struts of less than 60 microns
-
-
-
... More
Aortic Stent graft Self Expandable Bifurcated Diameter 23 mm or less and 34 mm or more with Delivery System & contralateral limb.
The manufacturer should agree to supply the size customized to the patient’s anatomy based on CT imaging
-
-
-
... More
Balloon-mounted, Sirolimus-eluting stent with biodegradable polymer on a Non-stainless-steel platform with uniform thin struts (60-80 microns)
-
-
-
... More
Peripheral balloon expendable Cobalt Chromium stent with high radial force with smaller introducer sheath, semi flexible hybrid cell design, with lengths from 13 mm up to 57 mm & diameter from 6 mm up to 32 mm.
-
-
-
... More
Balloon-mounted, Non-Medicated Stent on Stainless Steel platform
-
-
-
... More
Nitinol Monorail Closed cell design with flared ends- tapered, 6F Sheath Compatible
-
-
-
... More
Balloon Expandable Stent up to 30mm in Diameter
Stents are Composed of 0.013” platinum-iridium wire arranged in either an 8 zig or 10 zig patterns. Covered and Pre-mounted on Balloon in Balloon (Two Balloons on same shaft)
-
-
-
... More
Peripheral Cobalt Chromium Stent 5-10 mm diameter and length 15- 60 mm
-
-
-
... More
Peripheral Stainless-Steel Stent, Monorail, all sizes
-
-
-
... More
Balloon mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform thin struts (61-80 microns) of varying lengths including stent length of 8 mm or less, with at least one publication of the quoted product in PubMed indexed journal.
-
-
-
... More
C. Medicated Coronary stent – EVEROLIMUS ELUTING
-
-
-
... More
Balloon mounted, Everolimus eluting stent with biodegradable polymer on a Non-stainless-steel platform with strut thickness greater than 80 microns.
-
-
-
... More
K. Peripheral stents for Coarctation of Aorta
-
-
-
... More
Peripheral stainless-steel stent of diameter 5-10 mm and length 17-57 mm
-
-
-
... More
Nitinol Carotid Stent, 0.014" Guide Wire compatible, 5
– 10 mm Diameter- Non tapered
-
-
-
... More
Balloon Expandable Peripheral stent diameters upto 30 mm or more in various lengths.
-
-
-
... More
G. Balloon mounted Peripheral stents
-
-
-
... More
Peripheral Cobalt Chromium Stent, Monorail base, all sizes
-
-
-
... More
Balloon Expandable Stent up to 30mm in Diameter
Stents are Composed of 0.013” platinum-iridium wire arranged in either an 8 zig or 10 zig patterns
Un-Covered and Unmounted
-
-
-
... More
Aortic Stent graft system for thoracic endovascular aortic repair with Delivery System.
Proximal stent graft diameter from 22 mm or less to 46 mm or more in varying lengths.
The manufacturer should agree to supply the size customized to the patient’s anatomy based on CT imaging
-
-
-
... More
Balloon-mounted, Sirolimus-eluting stent with biodegradable polymer on a Non-stainless-steel platform with uniform thin struts (60-80 microns), with at least one publication of the quoted product in PubMed indexed journal.
-
-
-
... More
A. Non-Medicated Coronary Stent
-
-
-
... More
Coronary stent graft/ Coronary covered stent of variable diameters and lengths
-
-
-
... More
*Biodurable Polymers include SIBS (Polystyrene-b-isobutylene b-styrene), PBMA (poly n butyl methacrylate, PEVA (polyethylene covinyl acetate), PVDF-HFP (poly vinlidene fluoride hexafluoropropylene, PC (phosphorylcholine), Siloxane copolymer and any other commercially approved biodurable polymer
-
-
-
... More
Drug eluting peripheral stents of all diameters and varying lengths
-
-
-
... More
Extension tube graft for Aortic Stent Graft
-
-
-
... More
Self-expandable Stent graft expandable to 14 mm
-
-
-
... More
F. Peripheral vascular stents (Renal stents balloon mounted)
-
-
-
... More
Peripheral Cobalt Chromium Stent with thin struts, over the wire, 0.035” guide wire compatible, 6F Sheath compatible across all sizes (7 mm to 10 mm diameter)
-
-
-
... More
Monorail 0.014" wire compatible Cobalt Chromium renal stent of diameter 4-7 mm of varying lengths
-
-
-
... More
Balloon-mounted, Dual drug-coated Drug Eluting stents
-
-
-
... More
Nitinol Carotid Stent, 0.014" Guide Wire compatible, 5
- 10mm Diameter- tapered
-
-
-
... More
Monorail Balloon mounted Renal stents of diameter 4-7 mm of varying lengths
-
-
-
... More
Over the wire, 0.035” wire compatible, nitinol/ elgiloy peripheral self-expanding stent of diameter 5-14 mm and of varying lengths
-
-
-
... More
Balloon-mounted, Non medicated stent on Non- stainless-steel platform
-
-
-
... More
Balloon mounted, Sirolimus-eluting stent with biodurable/biostable polymer*
-
-
-
... More
Balloon mounted, Everolimus eluting stent on a Non- stainless-steel platform with uniform ultrathin struts (up to 80 microns) and diameters of 2.25 mm to 4.5 mm or more of varying lengths, with at least one publication of the quoted product in PubMed indexed journal.
-
-
-
... More
Balloon mounted, coronary drug (other than sirolimus) eluting stent with abluminal drug coating
-
-
-
... More
Balloon expandable Peripheral Stent graft of all diameters and varying lengths
-
-
-
... More
Balloon-mounted, Sirolimus-eluting stent with biodegradable polymer on stainless steel platform
-
-
-
... More
H. Self-expanding Peripheral stents
-
-
-
... More
0.035’’ wire compatible Nitinol/elgiloy peripheral self- expanding stent of all sizes and varying lengths
-
-
-
... More
Balloon-mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform ultrathin struts (up to 60 microns) and diameters inclusive of 2.0 mm to 4.0 mm of varying lengths, with at least one publication of the quoted product in PubMed indexed journal.
-
-
-
... More
Peripheral stainless-steel stent of diameter 11-14 mm and length 20-60 mm
-
-
-
... More
Monorail 0.014” wire compatible Cobalt Chromium renal stent of diameter 5-7 mm, of varying lengths, 5 F Compatible
-
-
-
... More
Over the wire, 0.035” wire compatible, nitinol/ elgiloy peripheral self-expanding stent of diameter 5-10 mm of varying lengths
-
-
-
... More
Over the wire, 0.035” wire compatible, nitinol/ elgiloy peripheral self-expanding stent of diameter 10-24 mm of varying lengths
-
-
-
... More
Balloon mounted, Zotarolimus eluting stent with biodurable/biostable polymer* on a Non-stainless-steel platform
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements