The DDA has issued a formal invitation for competitive bids for the Delhi Development Authority project, for M/o Dda Office Complex Sector-3, Rohini. in North West Delhi, Delhi, with an estimated contract value of Rs. 26,15,177. The bid opening date for this tender is 30-10-2026 and the last date for bid submission is 18-11-2026. Interested bidders for Delhi Development Authority tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Delhi Development Authority - DDA Tender - Delhi Tender
Opening Date30 Oct 2026
Closing Soon18 Nov 2026
Tender Amount₹ 26,15,177
Costs
EMD
₹ 52,304Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
M/o Dda Office Complex Sector-3, Rohini.
Description
m/o dda office complex sector-3, rohini. sub-head : operation & routine maintenance of dg set, submersible pump set, compound lighting and iei at divisional offices, lm office & nagrik suvidha kendra at dda office complex sector-3, rohini.
Contact
Tender Id
2026_DDA_932377_1Tender No
31/ EE/ ELD-9/ DDA/ NIT/ 2026-27Tender Authority
Delhi Development Authority ViewPurchaser Address
-Website
https://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Operation and Routine Maintenance of DG Set, Submersible Pump Set, Compound Lighting and IEI at Divisional Offices, LM Office and Nagrik Suvidha Kendra at DDA Office Complex Sector-3, Rohini.
BOQ Items
... More
b) 3 x 2.5 sq.mm
100
-
14100
... More
c) 3 x 4 sq. mm
200
-
42200
... More
Supply of following rating and capacity items ISI marked i/c rebate for dismantled material.
-
-
-
... More
a) S.P. 5/ 6 Amp ,one way Modular Switch
40
-
1760
... More
b) S.P. 15/ 16 Amp ,one way Modular Switch
20
-
1920
... More
c) 3-Pin 5/ 6 Amp Modular Socket Outlet
40
-
3280
... More
d) 6-Pin 15/ 16 Amp Modular Socket Outlet
20
-
2740
... More
e) 2 module stepped type modular fan regulator
20
-
5720
... More
f) combined switch & socket box 6/16A
10
-
2300
... More
g) Modular Bell push
15
-
1215
... More
h) Call bell/ buzzer, single phase
15
-
855
... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.i/c rebate for dismantled material.
-
-
-
... More
a) 200 A,36KA,FPMCCB
2
-
30316
... More
Supplying and replacement of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5℃ to 40℃, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) i/c rebate for dismantled material.
-
-
-
... More
a) Powder Coated CRCA Sheet Body (Thickness ≥ 0.50 mm) 40 watt
50
-
31500
... More
Supply and replacement of ceiling fan with Brush Less Direct current(BLDC) Motor, class of insulation: B,3 nos. metal(Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body power factor not less than 0.9, service value (CM/M/W) minimum as below, 350RPM(tolerence as per IS: 374-2019), THD(Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers temperature rise=75 degree C(max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 HZ, Single phase AC ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and earthing etc.as required i/c rebate for dismantle material .
-
-
-
... More
a)1200mm, service value ≥ 6.0CM/Min/watt,air delivery 210 CM/min (minimum)
20
-
51200
... More
Rewinding of 1200/ 1400 mm Sweep Ceiling Fan complete with varnishing, oiling and greasing,bearing replacement, quarter pin, replacement of 2.5 mfd capacitor with connection, testing & Installation at same position etc. complete as required i/c rebate for dismantle material.
40
-
28120
... More
Supplying and Replacement of 2.5/ 3.5 MFD or suitable Rating Capacitor suitable for Ceiling Fan Motor with connection, testing etc. complete as required i/c rebate for dismantle material.
40
-
7040
... More
Lifting out the Submersible Pump Set from the existing bore well i/c dismantling the GI Pipe, connection, testing etc. complete as required.
2
-
6168
... More
Lowering the Submersible Pump Set in the existing bore well i/c Water Proof Cable Joint, connection, testing etc. complete as required.
2
-
6908
... More
Supplying and Replacement of 5A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required i/c rebate for dismantled material.
-
-
-
... More
a) single pole
40
-
10840
... More
b) Double pole
20
-
13220
... More
Repair and rewinding of 5HP Submersible pump set i/c relacement of all burnt/ damaged parts and making connection, testing etc. as required. i/c rebate for dismantle material.
1
-
7031
... More
Repairing servicing of 40 KVA, 3 Phase DG Set i/c repairing/ Replacing of diesel & oil filter, fuel pump repair and caliberation, nozzle repair, battery terminal , engine oil, oil filter complete etc. as required.
1
-
19736
... More
Supply and replacement of 200 Amp ,4 pole ,3 phase with neutral ,Manual Changeover switch in SS Enclosure as per IS Standard with connections, testing and commissioning etc. as required i/c rebate for dismantled material.
2
-
39684
... More
Supplying of following sizes XLPE insulated Aluminium conductor cable of 1.1 KV grade armoured LT cable as required confirming to IS-7098 (Part-I) etc. as required.i/c rebate for dismantle material
-
-
-
... More
a) 4C x 10 Sq.mm
100
-
35500
... More
b) 4C x 95 Sq.mm
200
-
290800
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
-
-
-
... More
a)Upto 35 sq. mm
100
-
45300
... More
b)Above 35 sq. mm and upto 95 sq. mm
200
-